Sample records for sensor validation revision

  1. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 4; Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, J. L. (Editor); Fargion, Giuletta S. (Editor); McClain, Charles R. (Editor); Pegau, Scott; Zaneveld, J. Ronald V.; Mitchell, B. Gregg; Kahru, Mati; Wieland, John; Stramska, Malgorzat

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

  2. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4, Volume IV: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols

    NASA Technical Reports Server (NTRS)

    Mueller, J. L.; Fargion, G. S.; McClain, C. R. (Editor); Pegau, S.; Zanefeld, J. R. V.; Mitchell, B. G.; Kahru, M.; Wieland, J.; Stramska, M.

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.

  3. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 6; Special Topics in Ocean Optics Protocols and Appendices; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, J. L. (Editor); Fargion, Giulietta S. (Editor); McClain, Charles R. (Editor)

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

  4. Improving calibration and validation of cosmic-ray neutron sensors in the light of spatial sensitivity

    NASA Astrophysics Data System (ADS)

    Schrön, Martin; Köhli, Markus; Scheiffele, Lena; Iwema, Joost; Bogena, Heye R.; Lv, Ling; Martini, Edoardo; Baroni, Gabriele; Rosolem, Rafael; Weimar, Jannis; Mai, Juliane; Cuntz, Matthias; Rebmann, Corinna; Oswald, Sascha E.; Dietrich, Peter; Schmidt, Ulrich; Zacharias, Steffen

    2017-10-01

    In the last few years the method of cosmic-ray neutron sensing (CRNS) has gained popularity among hydrologists, physicists, and land-surface modelers. The sensor provides continuous soil moisture data, averaged over several hectares and tens of decimeters in depth. However, the signal still may contain unidentified features of hydrological processes, and many calibration datasets are often required in order to find reliable relations between neutron intensity and water dynamics. Recent insights into environmental neutrons accurately described the spatial sensitivity of the sensor and thus allowed one to quantify the contribution of individual sample locations to the CRNS signal. Consequently, data points of calibration and validation datasets are suggested to be averaged using a more physically based weighting approach. In this work, a revised sensitivity function is used to calculate weighted averages of point data. The function is different from the simple exponential convention by the extraordinary sensitivity to the first few meters around the probe, and by dependencies on air pressure, air humidity, soil moisture, and vegetation. The approach is extensively tested at six distinct monitoring sites: two sites with multiple calibration datasets and four sites with continuous time series datasets. In all cases, the revised averaging method improved the performance of the CRNS products. The revised approach further helped to reveal hidden hydrological processes which otherwise remained unexplained in the data or were lost in the process of overcalibration. The presented weighting approach increases the overall accuracy of CRNS products and will have an impact on all their applications in agriculture, hydrology, and modeling.

  5. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 1; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, James L. (Editor); Fargion, Giulietta (Editor); Mueller, J. L.; Trees, C.; Austin, R. W.; Pietras, C.; Hooker, S.; Holben, B.; McClain, Charles R.; Clark, D. K.; hide

    2002-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the SIMBIOS Project. It supersedes the earlier version, and is organized into four parts: Introductory Background, Instrument Characteristics, Field Measurements and Data Analysis, Data Reporting and Archival. Changes in this revision include the addition of three new chapters: (1) Fundamental Definitions, Relationships and Conventions; (2) MOBY, A Radiometric Buoy for Performance Monitoring and Vicarious Calibration of Satellite Ocean Color Sensors: Measurement and Data Analysis Protocols; and (3) Normalized Water-Leaving Radiance and Remote Sensing Reflectance: Bidirectional Reflectance and Other Factors. Although the present document represents another significant, incremental improvement in the ocean optics protocols, there are several protocols that have either been overtaken by recent technological progress, or have been otherwise identified as inadequate. Revision 4 is scheduled for completion sometime in 2003. This technical report is not meant as a substitute for scientific literature. Instead, it will provide a ready and responsive vehicle for the multitude of technical reports issued by an operational Project. The contributions are published as submitted, after only minor editing to correct obvious grammatical or clerical errors.

  6. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 2; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, James L. (Editor); Fargion, Giulietta S. (Editor); Trees, C.; Austin, R. W.; Pietras, C. (Editor); Hooker, S.; Holben, B.; McClain, Charles R.; Clark, D. K.; Yuen, M.

    2002-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the SIMBIOS Project. It supersedes the earlier version, and is organized into four parts: Introductory Background, Instrument Characteristics, Field Measurements and Data Analysis, Data Reporting and Archival. Changes in this revision include the addition of three new chapters: (1) Fundamental Definitions, Relationships and Conventions; (2) MOBY, A Radiometric Buoy for Performance Monitoring and Vicarious Calibration of Satellite Ocean Color Sensors: Measurement and Data Analysis Protocols; and (3) Normalized Water-Leaving Radiance and Remote Sensing Reflectance: Bidirectional Reflectance and Other Factors. Although the present document represents another significant, incremental improvement in the ocean optics protocols, there are several protocols that have either been overtaken by recent technological progress, or have been otherwise identified as inadequate. Revision 4 is scheduled for completion sometime in 2003. This technical report is not meant as a substitute for scientific literature. Instead, it will provide a ready and responsive vehicle for the multitude of technical reports issued by an operational Project. The contributions are published as submitted, after only minor editing to correct obvious grammatical or clerical errors.

  7. A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation.

    PubMed

    Ward, W Kenneth; Jansen, Lawrence B; Anderson, Ellen; Reach, Gerard; Klein, Jean-Claude; Wilson, George S

    2002-03-01

    For biosensor fabrication, it is important to optimize materials and methods in order to create predictable function in vitro and in vivo. For this reason, we designed a new glucose sensor ('revised protocol') that utilized an outer permselective membrane made of amphiphobic polyurethane which allows glucose passage through hydrophilic segments. An inner polyethersulfone membrane, stabilized with a trimethoxysilane, provided specificity. Before application of the inner membrane, it was necessary to etch the platinum electrode with a radio frequency oxygen plasma. The revised protocol sensors (n=185) were compared with sensors fabricated with an earlier ('original') protocol (n=204) which used an outer polyurethane without hydrophilic segments and a complex inner membrane of cellulose acetate and Nafion. The function of revised protocol sensors was more predictable in vitro as evidenced by a much lower variation of glucose sensitivity than the original protocol sensors. Revised and original protocol sensors were nearly linear up to a glucose concentration of 20 mM. In vitro interference from 0.1 mM acetaminophen was minimal in both groups of sensors and would be expected to represent about 2% of the total sensor response at normal glucose levels for revised protocol sensors. Prolonged testing of the revised protocol sensors for 11 days during immersion in buffer revealed stable sensitivities (day 1: 6.12+/-1.34 nA/mM; day 3: 6.33+/-1.40; day 8: 7.13+/-1.39; and day 11: 7.56+/-1.47; sensitivity for day 1 vs. each other day: not significant) and no critical loss of glucose oxidase activity. The response of the revised protocol sensors (n=7) to intraperitoneal glucose was tested in rats approximately one day after subcutaneous implantation and the sensors tracked glucose closely with a slight lag of 3-6 min.

  8. Sensor failure detection for jet engines

    NASA Technical Reports Server (NTRS)

    Beattie, E. C.; Laprad, R. F.; Akhter, M. M.; Rock, S. M.

    1983-01-01

    Revisions to the advanced sensor failure detection, isolation, and accommodation (DIA) algorithm, developed under the sensor failure detection system program were studied to eliminate the steady state errors due to estimation filter biases. Three algorithm revisions were formulated and one revision for detailed evaluation was chosen. The selected version modifies the DIA algorithm to feedback the actual sensor outputs to the integral portion of the control for the nofailure case. In case of a failure, the estimates of the failed sensor output is fed back to the integral portion. The estimator outputs are fed back to the linear regulator portion of the control all the time. The revised algorithm is evaluated and compared to the baseline algorithm developed previously.

  9. SeaWiFS Technical Report Series. Volume 41; Case Studies for SeaWiFS Calibration and Validation

    NASA Technical Reports Server (NTRS)

    Yeh, Eueng-nan; Barnes, Robert A.; Darzi, Michael; Kumar, Lakshmi; Early, Edward A.; Johnson, B. Carol; Mueller, James L.; Trees, Charles C.

    1997-01-01

    This document provides brief reports, or case studies, on a number of investigations sponsored by the Calibration and Validation Team (CVT) within the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project. Chapter I describes the calibration and characterization of the GSFC sphere, which was used in the recent recalibration of the SeaWiFS instrument. Chapter 2 presents a revision of the diffuse attenuation coefficient, K(490), algorithm based on the SeaWiFS wavelengths. Chapter 3 provides an implementation scheme for an algorithm to remove out-of-band radiance when using a sensor calibration based on a finite width (truncated) spectral response function, e.g., between the 1% transmission points. Chapter 4 describes the implementation schemes for the stray light quality flag (local area coverage [LAC] and global area coverage [GAC]) and the LAC stray light correction.

  10. A revised surface resistance parameterisation for estimating latent heat flux from remotely sensed data

    NASA Astrophysics Data System (ADS)

    Song, Yi; Wang, Jiemin; Yang, Kun; Ma, Mingguo; Li, Xin; Zhang, Zhihui; Wang, Xufeng

    2012-07-01

    Estimating evapotranspiration (ET) is required for many environmental studies. Remote sensing provides the ability to spatially map latent heat flux. Many studies have developed approaches to derive spatially distributed surface energy fluxes from various satellite sensors with the help of field observations. In this study, remote-sensing-based λE mapping was conducted using a Landsat Thematic Mapper (TM) image and an Enhanced Thematic Mapper Plus (ETM+) image. The remotely sensed data and field observations employed in this study were obtained from Watershed Allied Telemetry Experimental Research (WATER). A biophysics-based surface resistance model was revised to account for water stress and temperature constraints. The precision of the results was validated using 'ground truth' data obtained by eddy covariance (EC) system. Scale effects play an important role, especially for parameter optimisation and validation of the latent heat flux (λE). After considering the footprint of EC, the λE derived from the remote sensing data was comparable to the EC measured value during the satellite's passage. The results showed that the revised surface resistance parameterisation scheme was useful for estimating the latent heat flux over cropland in arid regions.

  11. Effects of indigo carmine intravenous injection on noninvasive and continuous total hemoglobin measurement with using the Revision L sensor.

    PubMed

    Isosu, Tsuyoshi; Obara, Shinju; Hakozaki, Takahiro; Imaizumi, Tsuyoshi; Iseki, Yuzo; Mogami, Midori; Ohashi, Satoshi; Ikegami, Yukihiro; Kurosawa, Shin; Murakawa, Masahiro

    2017-04-01

    The effects of intravenous injection of indigo carmine on noninvasive and continuous total hemoglobin (SpHb) measurement were retrospectively evaluated with the Revision L sensor. The subjects were 18 patients who underwent elective gynecologic surgery under general anesthesia. During surgery, 5 mL of 0.4 % indigo carmine was injected intravenously, and changes in SpHb concentrations between before and after the injection were evaluated. The mean age was 52.4 ± 12.8 years. Before injection, the median SpHb level was 10.1 (range, 6.8-13.4) g/dL. The results demonstrated no change in SpHb concentration between before and after indigo carmine injection as detected by the Revision L sensor. SpHb measurements as determined with the Revision L sensor were not affected, even after the intravenous injection of indigo carmine.

  12. SeaWiFS technical report series. Volume 25: Ocean optics protocols for SeaWiFS validation, revision 1

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Acker, James G. (Editor); Mueller, James L.; Austin, Roswell W.

    1995-01-01

    This report presents protocols for measuring optical properties, and other environmental variables, to validate the radiometric performance of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), and to develop and validate bio-optical algorithms for use with SeaWiFS data. The protocols are intended to establish foundations for a measurement strategy to verify the challenging SeaWiFS uncertainty goals of 5 percent in water-leaving radiances and 35 percent in chlorophyll alpha concentration. The protocols first specify the variables which must be measured, and briefly review the rationale for measuring each variable. Subsequent chapters cover detailed protocols for instrument performance specifications, characterizing and calibrating instruments, methods of making measurements in the field, and methods of data analysis. These protocols were developed at a workshop sponsored by the SeaWiFS Project Office (SPO) and held at the Naval Postgraduate School in Monterey, California (9-12 April 1991). This report began as the proceedings of the workshop, as interpreted and expanded by the authors and reviewed by workshop participants and other members of the bio-optical research community. The protocols are an evolving prescription to allow the research community to approach the unprecedented measurement uncertainties implied by the SeaWiFS goals; research and development are needed to improve the state-of-the-art in specific areas. These protocols should be periodically revised to reflect technical advances during the SeaWiFS Project cycle. The present edition (Revision 1) incorporates new protocols in several areas, including expanded protocol descriptions for Case-2 waters and other improvements, as contributed by several members of the SeaWiFS Science Team.

  13. A Framework for Mixing Methods in Quantitative Measurement Development, Validation, and Revision: A Case Study

    ERIC Educational Resources Information Center

    Luyt, Russell

    2012-01-01

    A framework for quantitative measurement development, validation, and revision that incorporates both qualitative and quantitative methods is introduced. It extends and adapts Adcock and Collier's work, and thus, facilitates understanding of quantitative measurement development, validation, and revision as an integrated and cyclical set of…

  14. Intra-annual NDVI validation of the Landsat 5 TM radiometric calibration

    USGS Publications Warehouse

    Chander, G.; Groeneveld, D.P.

    2009-01-01

    Multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provide the backbone of the extensive archive of moderate‐resolution Earth imagery. Even after more than 24 years of service, the L5 TM is still operational. Given the longevity of the satellite, the detectors have aged and the sensor's radiometric characteristics have changed since launch. The calibration procedures and parameters in the National Land Archive Production System (NLAPS) have also changed with time. Revised radiometric calibrations in 2003 and 2007 have improved the radiometric accuracy of recently processed data. This letter uses the Normalized Difference Vegetation Index (NDVI) as a metric to evaluate the radiometric calibration. The calibration change has improved absolute calibration accuracy, consistency over time, and consistency with Landsat 7 (L7) Enhanced Thematic radiometry and will provide the basis for continued long‐term studies of the Earth's land surfaces.

  15. Improved Diagnostic Validity of the ADOS Revised Algorithms: A Replication Study in an Independent Sample

    ERIC Educational Resources Information Center

    Oosterling, Iris; Roos, Sascha; de Bildt, Annelies; Rommelse, Nanda; de Jonge, Maretha; Visser, Janne; Lappenschaar, Martijn; Swinkels, Sophie; van der Gaag, Rutger Jan; Buitelaar, Jan

    2010-01-01

    Recently, Gotham et al. ("2007") proposed revised algorithms for the Autism Diagnostic Observation Schedule (ADOS) with improved diagnostic validity. The aim of the current study was to replicate predictive validity, factor structure, and correlations with age and verbal and nonverbal IQ of the ADOS revised algorithms for Modules 1 and 2…

  16. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Revised

    NASA Technical Reports Server (NTRS)

    Fargion, Giulietta S.; Mueller, James L.

    2000-01-01

    The document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. This document supersedes the earlier version (Mueller and Austin 1995) published as Volume 25 in the SeaWiFS Technical Report Series. This document marks a significant departure from, and improvement on, theformat and content of Mueller and Austin (1995). The authorship of the protocols has been greatly broadened to include experts specializing in some key areas. New chapters have been added to provide detailed and comprehensive protocols for stability monitoring of radiometers using portable sources, abovewater measurements of remote-sensing reflectance, spectral absorption measurements for discrete water samples, HPLC pigment analysis and fluorometric pigment analysis. Protocols were included in Mueller and Austin (1995) for each of these areas, but the new treatment makes significant advances in each topic area. There are also new chapters prescribing protocols for calibration of sun photometers and sky radiance sensors, sun photometer and sky radiance measurements and analysis, and data archival. These topic areas were barely mentioned in Mueller and Austin (1995).

  17. 78 FR 25666 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-02

    ...) sensor blockage. The existing AD also provides for optional terminating action for the AFM revision, which involves replacing AoA sensor conic plates with AoA sensor flat plates. Since we issued that AD, we have determined that the replacement of AoA sensor conic plates is necessary to address the...

  18. Development and Psychometric Validation of the Family Outcomes Survey-Revised

    ERIC Educational Resources Information Center

    Bailey, Donald B., Jr.; Raspa, Melissa; Olmsted, Murrey G.; Novak, Scott P.; Sam, Ann M.; Humphreys, Betsy P.; Nelson, Robin; Robinson, Nyle; Guillen, Chelsea

    2011-01-01

    Few psychometrically valid scales exist to assess family outcomes and the helpfulness of early intervention. This article describes the development and psychometric properties of the Family Outcomes Survey-Revised. The revision was prompted by the need to (a) create a new format that would be easier for parents to understand, (b) revise and expand…

  19. Revision and Validation of the Revised Teacher Beliefs Survey.

    ERIC Educational Resources Information Center

    Benjamin, Jane

    This study revised the Teacher Beliefs Survey (S. Wooley and A. Wooley, 1999; TBS), an instrument to assess teachers beliefs related to constructivist and behaviorist theories of learning, and then studied the validity of the revised TBS. Drawing on a literature review, researchers added items for the existing constructs of the TBS and added a new…

  20. Improving the Validity and Reliability of a Health Promotion Survey for Physical Therapists

    PubMed Central

    Stephens, Jaca L.; Lowman, John D.; Graham, Cecilia L.; Morris, David M.; Kohler, Connie L.; Waugh, Jonathan B.

    2013-01-01

    Purpose Physical therapists (PTs) have a unique opportunity to intervene in the area of health promotion. However, no instrument has been validated to measure PTs’ views on health promotion in physical therapy practice. The purpose of this study was to evaluate the content validity and test-retest reliability of a health promotion survey designed for PTs. Methods An expert panel of PTs assessed the content validity of “The Role of Health Promotion in Physical Therapy Survey” and provided suggestions for revision. Item content validity was assessed using the content validity ratio (CVR) as well as the modified kappa statistic. Therapists then participated in the test-retest reliability assessment of the revised health promotion survey, which was assessed using a weighted kappa statistic. Results Based on feedback from the expert panelists, significant revisions were made to the original survey. The expert panel reached at least a majority consensus agreement for all items in the revised survey and the survey-CVR improved from 0.44 to 0.66. Only one item on the revised survey had substantial test-retest agreement, with 55% of the items having moderate agreement and 43% poor agreement. Conclusions All items on the revised health promotion survey demonstrated at least fair validity, but few items had reasonable test-retest reliability. Further modifications should be made to strengthen the validity and improve the reliability of this survey. PMID:23754935

  1. Road Weather Systems [SD .WMV (720x480/29fps/25.2 MB)

    DOT National Transportation Integrated Search

    2009-01-01

    Iowas road weather information system at work. The Iowa DOT will install new sensors and upgrades to most road weather information system (RWIS) sites. These include: : color cameras, new precipitation sensors, new speed sensors, revised weathervi...

  2. The Phoenix TECP Relative Humidity Sensor: Revised Results

    NASA Technical Reports Server (NTRS)

    Zent, Aaron

    2014-01-01

    The original calibration function of the RH sensor on the Phoenix mission's Thermal and Electrical Conductivity Sensor (TECP), has been revised to correct the erroneously-published original calibration equation, to demonstrate the value of this unique data set, and to improve characterization of H2O exchange between the martian regolith and atmosphere. TECP returned two data streams, the temperature of the electronics analog board (Tb) and the digital 12-bit output of the RH sensor (DN), both of which are required to uniquely specify the H2O abundance. Because the original flight instrument calibration was performed against a pair of hygrometers that measured frost point (Tf), the revised calibration equation is also cast in terms of frost point. The choice of functional form for the calibration function is minimally constrained. A series of profiles across the calibration data cloud at constant DN and Tb does not reveal any evidence of a complex functional form. Therefore, a series of polynomials in both DN and Tb was investigated, along with several non-linear functions of DN and Tb.

  3. Visual reproduction subtest of the Wechsler Memory Scale-Revised: analysis of construct validity.

    PubMed

    Williams, M A; Rich, M A; Reed, L K; Jackson, W T; LaMarche, J A; Boll, T J

    1998-11-01

    This study assessed the construct validity of Visual Reproduction (VR) Cards A (Flags) and B (Boxes) from the original Wechsler Memory Scale (WMS) compared to Flags and Boxes from the revised edition of the WMS (WMS-R). Independent raters scored Flags and Boxes using both the original and revised scoring criteria and correlations were obtained with age, education, IQ, and four separate criterion memory measures. Results show that for Flags, there is a tendency for the revised scoring criteria to produce improved construct validity. For Boxes, however, there was a trend in the opposite direction, with the revised scoring criteria demonstrating worse construct validity. Factor analysis suggests that Flags are a more distinct measure of visual memory, whereas Boxes are more complex and significantly associated with conceptual reasoning abilities. Using the revised scoring criteria, Boxes were found to be more strongly related to IQ than Flags. This difference was not found using the original scoring criteria.

  4. The Added Value of the Combined Use of the Autism Diagnostic Interview-Revised and the Autism Diagnostic Observation Schedule: Diagnostic Validity in a Clinical Swedish Sample of Toddlers and Young Preschoolers

    ERIC Educational Resources Information Center

    Zander, Eric; Sturm, Harald; Bölte, Sven

    2015-01-01

    The diagnostic validity of the new research algorithms of the Autism Diagnostic Interview-Revised and the revised algorithms of the Autism Diagnostic Observation Schedule was examined in a clinical sample of children aged 18-47 months. Validity was determined for each instrument separately and their combination against a clinical consensus…

  5. 77 FR 47552 - Event Data Recorders

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-09

    ... uncertainties in multiple event crashes; Revised certain sensor ranges and accuracies to reflect current state... resolution specification of 5 degrees. In its petition the Alliance stated that steering wheel angle sensors... angle sensors. Both Nissan and GAM submitted comments in support of the Alliance and Honda petitions to...

  6. RCBI-II: The Second Revision of the Revised Cyber Bullying Inventory

    ERIC Educational Resources Information Center

    Topcu, Çigdem; Erdur-Baker, Özgür

    2018-01-01

    The aim of this study is to update the Turkish version of the Revised Cyber Bullying Inventory (RCBI) and eliminate specific technology names. Validity and reliability tests were carried out with 1,803 high school students. The updated version of the RCBI yields valid and reliable scores measuring cyberbullying and victimization.

  7. Reliability and Validity of the Early Childhood Environment Rating Scale, Revised Edition, ECERS-R in Arabic

    ERIC Educational Resources Information Center

    Hadeed, Julie

    2014-01-01

    The aim of this study was to test reliabilities and validations for the Arabic translation of the Early Childhood Environment Rating Scale, Revised (ECERS-R) scale [Harms, T., Clifford, R. M., & Cryer, D. (1998). "Early childhood environment rating scale, revised edition." New York: Teachers College Press]. ECERS-R mean scores were…

  8. Validity and Appropriate Uses of the Revised Technology Uses and Perceptions Survey (TUPS)

    ERIC Educational Resources Information Center

    Ritzhaupt, Albert D.; Huggins-Manley, A. Corinne; Dawson, Kara; Agaçli-Dogan, Nihan; Dogan, Selcuk

    2017-01-01

    The purpose of this article is to explore validity evidence and appropriate uses of the revised Technology Uses and Perceptions Survey (TUPS) designed to measure in-service teacher perspectives about technology integration in K-12 schools and classrooms. The revised TUPS measures 10 domains, including Access and Support; Preparation of Technology…

  9. A Revised Calibration Function and Results for the Phoenix Mission TECP Relative Humidity Sensor

    NASA Technical Reports Server (NTRS)

    Zent, Aaron

    2014-01-01

    The original calibration function of the R(sub H) sensor on the Phoenix Thermal and Electrical Conductivity Sensor (TECP) has been revised in order to extend the range of the valid calibration, and to improve accuracy. The original function returned non-physical R(sub H) values at the lowest temperatures. To resolve this, and because the original calibration was performed against a pair of hygrometers that measured frost point (T(sub f)), the revised calibration equation is also cast in terms of frost point. Because of the complexity of maintaining very low temperatures and high R(sub H) in the laboratory, no calibration data exists at T is greater than 203K. However, sensor response during the mission was smooth and continuous down to 181 K. Therefore we have opted to include flight data in the calibration data set; selection was limited to data acquired during periods when the atmosphere is known to have been saturated. T(sub f) remained below 210 K throughout the mission(P is greater than 0.75 Pa). R(sub H), conversely, ranged from 1 to well under 0.01 diurnally, due to approximately 50 K temperature variations. To first order, both vapor pressure and its variance are greater during daylight hours. Variance in overnight humidity is almost entirely explained by temperature, while atmospheric turbulence contributes substantial variance to daytime humidity. Likewise, data gathered with the TECP aloft reflect higher H2O abundances than at the surface, as well as greater variance. There is evidence for saturation of the atmosphere overnight throughout much of the mission. In virtually every overnight observation, once the atmosphere cooled to T(sub f), water vapor begins to decrease, and tracks air temperature. There is no evidence for substantial decreases in water vapor prior to saturation, as expected for adsorptive exchange. Likewise, there is no evidence of local control of vapor by phases such as perchlorate hydrates hydrated minerals. The daytime average H2O pressure does not change substantially over the course of the mission, although the H2O column abundance varies by a factor of 2. Column abundances calculated from TECP data are lower than orbital measurements if one assumes that H2O is uniformly mixed through a single scale height. These results argue that the vertical distribution of H2O begins to change well in advance of surface concentrations as northern autumn approaches.

  10. Method of validating measurement data of a process parameter from a plurality of individual sensor inputs

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1998-01-01

    A method for generating a validated measurement of a process parameter at a point in time by using a plurality of individual sensor inputs from a scan of said sensors at said point in time. The sensor inputs from said scan are stored and a first validation pass is initiated by computing an initial average of all stored sensor inputs. Each sensor input is deviation checked by comparing each input including a preset tolerance against the initial average input. If the first deviation check is unsatisfactory, the sensor which produced the unsatisfactory input is flagged as suspect. It is then determined whether at least two of the inputs have not been flagged as suspect and are therefore considered good inputs. If two or more inputs are good, a second validation pass is initiated by computing a second average of all the good sensor inputs, and deviation checking the good inputs by comparing each good input including a present tolerance against the second average. If the second deviation check is satisfactory, the second average is displayed as the validated measurement and the suspect sensor as flagged as bad. A validation fault occurs if at least two inputs are not considered good, or if the second deviation check is not satisfactory. In the latter situation the inputs from each of all the sensors are compared against the last validated measurement and the value from the sensor input that deviates the least from the last valid measurement is displayed.

  11. Hyperion 5113/A Infrasound Sensor Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merchant, Bion John

    2015-09-01

    Sandia National Laboratories has tested and evaluated an infrasound sensor, the 5113/A manufactured by Hyperion. These infrasound sensors measure pressure output by a methodology developed by the University of Mississippi. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, and dynamic range. The 5113/A infrasound sensor is a new revision of the 5000 series intended to meet the infrasound application requirements for use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

  12. Reliability and Validity of the Social Anxiety Scale for Children--Revised for Hispanic Children.

    ERIC Educational Resources Information Center

    Storch, Eric A.; Eisenberg, Philip S.; Roberti, Jonathan W.; Barlas, Mitchell E.

    2003-01-01

    A study examined the psychometric properties of the Social Anxiety Scale for Children--Revised (SASC-R) in a sample of 159 predominantly Dominican and Puerto Rican fifth- and sixth-grade students from New York City. Findings provided initial support for SASC-R reliability and validity in Hispanic children. Convergent validity was supported by…

  13. Confirmatory Factor Analysis of a Family Quality of Life Scale for Taiwanese Families of Children with Intellectual Disability/Developmental Delay

    ERIC Educational Resources Information Center

    Chiu, Chun-Yu; Seo, Hyojeong; Turnbull, Ann P.; Summer, Jean Ann

    2017-01-01

    The Beach Center Family Quality of Life Scale is an internationally validated instrument for measuring family outcomes. To revise the scale for better alignment with the Family Quality of Life theory, the authors excluded non-outcome items in this revision. In this study, we examined reliability and validity of the revised scale (i.e., the FQoL…

  14. Psychometric properties of Conversion Disorder Scale- Revised (CDS) for children.

    PubMed

    Ijaz, Tazvin; Nasir, Attikah; Sarfraz, Naema; Ijaz, Shirmeen

    2017-05-01

    To revise conversion disorder scale and to establish the psychometric properties of the revised scale. This case-control study was conducted from February to June, 2014, at the Government College University, Lahore, Pakistan, and comprised schoolchildren and children with conversion disorder. In order to generate items for revised version of conversion disorder scale, seven practising mental health professionals were consulted. A list of 42 items was finalised for expert ratings. After empirical validation, a scale of 40 items was administered on the participants and factor analysis was conducted. Of the240 participants, 120(50%) were schoolchildren (controls group) and 120(50%)were children with conversion disorder (clinical group).The results of factor analysis revealed five factors (swallowing and speech symptoms, motor symptoms, sensory symptoms, weakness and fatigue, and mixed symptoms) and retention of all 40 items of revised version of conversion disorder scale. Concurrent validity of the revised scale was found to be 0.81 which was significantly high. Similarly, discriminant validity of the scale was also high as both clinical and control groups had significant difference (p<0.001) in scores. Cronbach's alpha of scale was a=0.91 while item total correlation ranged from 0.50 to 0.80. The sensitivity and specificity analysis indicated that the revised conversion disorder scale was 76% sensitive to predicting conversion disorder while specificity showed that the scale was 73% accurate in specifying participants of the control group. The revised version of conversion disorder scale was a reliable and valid tool to be used for screening of children with conversion disorder.

  15. Cross-Cultural Validity of the Almost Perfect Scale-Revised on the College Students in the United States and Turkey

    ERIC Educational Resources Information Center

    Aydin, Kamile Bahar

    2013-01-01

    This study investigated the cultural validity of the almost perfect scale-revised (APS-R) with 300 Turkish and 300 American and international college students. First, the validity of the original APS-R was conducted on American students and international students. Hence, exploratory factor analysis (EFA) offered two-factor scale to be consistent…

  16. The development and validation of the Physical Appearance Comparison Scale-Revised (PACS-R).

    PubMed

    Schaefer, Lauren M; Thompson, J Kevin

    2014-04-01

    The Physical Appearance Comparison Scale (PACS; Thompson, Heinberg, & Tantleff, 1991) was revised to assess appearance comparisons relevant to women and men in a wide variety of contexts. The revised scale (Physical Appearance Comparison Scale-Revised, PACS-R) was administered to 1176 college females. In Study 1, exploratory factor analysis and parallel analysis using one half of the sample suggested a single factor structure for the PACS-R. Study 2 utilized the remaining half of the sample to conduct confirmatory factor analysis, item analysis, and to examine the convergent validity of the scale. These analyses resulted in an 11-item measure that demonstrated excellent internal consistency and convergent validity with measures of body satisfaction, eating pathology, sociocultural influences on appearance, and self-esteem. Regression analyses demonstrated the utility of the PACS-R in predicting body satisfaction and eating pathology. Overall, results indicate that the PACS-R is a reliable and valid tool for assessing appearance comparison tendencies in women. Copyright © 2014. Published by Elsevier Ltd.

  17. Validity of Factors of the Psychopathy Checklist-Revised in Female Prisoners: Discriminant Relations with Antisocial Behavior, Substance Abuse, and Personality

    ERIC Educational Resources Information Center

    Kennealy, Patrick J.; Hicks, Brian M.; Patrick, Christopher J.

    2007-01-01

    The validity of the Psychopathy Checklist-Revised (PCL-R) has been examined extensively in men, but its validity for women remains understudied. Specifically, the correlates of the general construct of psychopathy and its components as assessed by PCL-R total, factor, and facet scores have yet to be examined in depth. Based on previous research…

  18. Incremental Validity of the Minnesota Multiphasic Personality Inventory-2 and Symptom Checklist-90-Revised with Mental Health Inpatients

    ERIC Educational Resources Information Center

    Simonds, Elise C.; Handel, Richard W.; Archer, Robert P.

    2008-01-01

    This study evaluated the incremental validity of scores from the Minnesota Multiphasic Personality Inventory-2 (MMPI-2) and the Symptom Checklist-90-Revised (SCL-90-R) in a sample of mental health inpatients originally published by Archer, Griffin, and Aiduk (1995). The incremental validity of scores from the SCL-90-R primary symptom dimensions…

  19. Measuring Moral Distress Among Critical Care Clinicians: Validation and Psychometric Properties of the Italian Moral Distress Scale-Revised.

    PubMed

    Lamiani, Giulia; Setti, Ilaria; Barlascini, Luca; Vegni, Elena; Argentero, Piergiorgio

    2017-03-01

    Moral distress is a common experience among critical care professionals, leading to frustration, withdrawal from patient care, and job abandonment. Most of the studies on moral distress have used the Moral Distress Scale or its revised version (Moral Distress Scale-Revised). However, these scales have never been validated through factor analysis. This article aims to explore the factorial structure of the Moral Distress Scale-Revised and develop a valid and reliable scale through factor analysis. Validation study using a survey design. Eight medical-surgical ICUs in the north of Italy. A total of 184 clinicians (64 physicians, 94 nurses, and 14 residents). The Moral Distress Scale-Revised was translated into Italian and administered along with a measure of depression (Beck Depression Inventory-Second Edition) to establish convergent validity. Exploratory factor analysis was conducted to explore the Moral Distress Scale-Revised factorial structure. Items with low (less than or equal to 0.350) or multiple saturations were removed. The resulting model was tested through confirmatory factor analysis. The Italian Moral Distress Scale-Revised is composed of 14 items referring to four factors: futile care, poor teamwork, deceptive communication, and ethical misconduct. This model accounts for 59% of the total variance and presents a good fit with the data (root mean square error of approximation = 0.06; comparative fit index = 0.95; Tucker-Lewis index = 0.94; weighted root mean square residual = 0.65). The Italian Moral Distress Scale-Revised evinces good reliability (α = 0.81) and moderately correlates with Beck Depression Inventory-Second Edition (r = 0.293; p < 0.001). No significant differences were found in the moral distress total score between physicians and nurses. However, nurses scored higher on futile care than physicians (t = 2.051; p = 0.042), whereas physicians scored higher on deceptive communication than nurses (t = 3.617; p < 0.001). Moral distress was higher for those clinicians considering to give up their position (t = 2.778; p = 0.006). The Italian Moral Distress Scale-Revised is a valid and reliable instrument to assess moral distress among critical care clinicians and develop tailored interventions addressing its different components. Further research could test the generalizability of its factorial structure in other cultures.

  20. Operations and Maintenance Manual, Atmospheric Contaminant Sensor, Revision B.

    ERIC Educational Resources Information Center

    National Aeronautics and Space Administration, Washington, DC.

    The sensor is a mass spectrometer system which continuously monitors the atmospheric constituents of hydrogen, water vapor, nitrogen, oxygen, and carbon dioxide, and monitors the Freons on a demand sampling basis. The manual provides a system description, operational procedures, and maintenance and troubleshooting instructions. Circuit diagrams…

  1. Opportunistic Mobility Support for Resource Constrained Sensor Devices in Smart Cities

    PubMed Central

    Granlund, Daniel; Holmlund, Patrik; Åhlund, Christer

    2015-01-01

    A multitude of wireless sensor devices and technologies are being developed and deployed in cities all over the world. Sensor applications in city environments may include highly mobile installations that span large areas which necessitates sensor mobility support. This paper presents and validates two mechanisms for supporting sensor mobility between different administrative domains. Firstly, EAP-Swift, an Extensible Authentication Protocol (EAP)-based sensor authentication protocol is proposed that enables light-weight sensor authentication and key generation. Secondly, a mechanism for handoffs between wireless sensor gateways is proposed. We validate both mechanisms in a real-life study that was conducted in a smart city environment with several fixed sensors and moving gateways. We conduct similar experiments in an industry-based anechoic Long Term Evolution (LTE) chamber with an ideal radio environment. Further, we validate our results collected from the smart city environment against the results produced under ideal conditions to establish best and real-life case scenarios. Our results clearly validate that our proposed mechanisms can facilitate efficient sensor authentication and handoffs while sensors are roaming in a smart city environment. PMID:25738767

  2. Opportunistic mobility support for resource constrained sensor devices in smart cities.

    PubMed

    Granlund, Daniel; Holmlund, Patrik; Åhlund, Christer

    2015-03-02

    A multitude of wireless sensor devices and technologies are being developed and deployed in cities all over the world. Sensor applications in city environments may include highly mobile installations that span large areas which necessitates sensor mobility support. This paper presents and validates two mechanisms for supporting sensor mobility between different administrative domains. Firstly, EAP-Swift, an Extensible Authentication Protocol (EAP)-based sensor authentication protocol is proposed that enables light-weight sensor authentication and key generation. Secondly, a mechanism for handoffs between wireless sensor gateways is proposed. We validate both mechanisms in a real-life study that was conducted in a smart city environment with several fixed sensors and moving gateways. We conduct similar experiments in an industry-based anechoic Long Term Evolution (LTE) chamber with an ideal radio environment. Further, we validate our results collected from the smart city environment against the results produced under ideal conditions to establish best and real-life case scenarios. Our results clearly validate that our proposed mechanisms can facilitate efficient sensor authentication and handoffs while sensors are roaming in a smart city environment.

  3. Operations and maintenance manual, atmospheric contaminant sensor, revision B

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The sensor is a mass spectrometer system which continuously monitors the atmospheric constituents of hydrogen, water vapor, nitrogen, oxygen, and carbon dioxide, and monitors the Freons on a demand sampling basis. The manual provides a system description, operational procedures, and maintenance and troubleshooting instructions. Circuit diagrams are included.

  4. Empirical Refinements of a Molecular Genetics Learning Progression: The Molecular Constructs

    ERIC Educational Resources Information Center

    Todd, Amber; Kenyon, Lisa

    2016-01-01

    This article describes revisions to four of the eight constructs of the Duncan molecular genetics learning progression [Duncan, Rogat, & Yarden, (2009)]. As learning progressions remain hypothetical models until validated by multiple rounds of empirical studies, these revisions are an important step toward validating the progression. Our…

  5. Objectivity, Reliability, and Validity of the Bent-Knee Push-Up for College-Age Women

    ERIC Educational Resources Information Center

    Wood, Heather M.; Baumgartner, Ted A.

    2004-01-01

    The revised push-up test has been found to have good validity but it produces many zero scores for women. Maybe there should be an alternative to the revised push-up test for college-age women. The purpose of this study was to determine the objectivity, reliability, and validity for the bent-knee push-up test (executed on hands and knees) for…

  6. The Padua Inventory: Do Revisions Need Revision?

    ERIC Educational Resources Information Center

    Gonner, Sascha; Ecker, Willi; Leonhart, Rainer

    2010-01-01

    The purpose of the present study was to examine the psychometric properties, factorial structure, and validity of the Padua Inventory-Washington State University Revision and of the Padua Inventory-Revised in a large sample of patients with obsessive-compulsive disorder (n = 228) and with anxiety disorders and/or depression (n = 213). The…

  7. Group power through the lens of the 21st century and beyond: further validation of the Sieloff-King Assessment of Group Power within Organizations.

    PubMed

    Sieloff, Christina L; Bularzik, Anne M

    2011-11-01

    The purpose was to determine the content validity of a semantic revision of items on a reliable and valid instrument, the Sieloff-King Assessment of Group Power within Organizations (SKAGPO). Research participants expressed negative perceptions regarding the use of the concept of 'power' in SKAGPO items. The SKAGPO is the only instrument measuring a nursing group's power or outcome attainment. Using a survey method, the instrument and grading scale were sent to 12 expert judges. Six participants completed the grading scale. The Content Validity Index (CVI) for seven questions was at or above 83% agreement. Overall, the CVI for the eight revised questions was 93.75%. Subsequently, the instrument was renamed the Sieloff-King Assessment of Group Outcome Attainment within Organizations (SKAGOAO). The semantic revision demonstrated content validity for the revised SKAGOAO. When used by nursing groups to assess their level of outcome attainment, the instrument should continue to be psychometrically evaluated. A nursing group of any size can use the SKAGOAO to both assess the group's level of outcome attainment or empowerment and direct plans to further improve that level. © 2011 Blackwell Publishing Ltd.

  8. Reliability and Validity of Autism Diagnostic Interview-Revised, Japanese Version

    ERIC Educational Resources Information Center

    Tsuchiya, Kenji J.; Matsumoto, Kaori; Yagi, Atsuko; Inada, Naoko; Kuroda, Miho; Inokuchi, Eiko; Koyama, Tomonori; Kamio, Yoko; Tsujii, Masatsugu; Sakai, Saeko; Mohri, Ikuko; Taniike, Masako; Iwanaga, Ryoichiro; Ogasahara, Kei; Miyachi, Taishi; Nakajima, Shunji; Tani, Iori; Ohnishi, Masafumi; Inoue, Masahiko; Nomura, Kazuyo; Hagiwara, Taku; Uchiyama, Tokio; Ichikawa, Hironobu; Kobayashi, Shuji; Miyamoto, Ken; Nakamura, Kazuhiko; Suzuki, Katsuaki; Mori, Norio; Takei, Nori

    2013-01-01

    To examine the inter-rater reliability of Autism Diagnostic Interview-Revised, Japanese Version (ADI-R-JV), the authors recruited 51 individuals aged 3-19 years, interviewed by two independent raters. Subsequently, to assess the discriminant and diagnostic validity of ADI-R-JV, the authors investigated 317 individuals aged 2-19 years, who were…

  9. Field Validity of the Psychopathy Checklist--Revised in Sex Offender Risk Assessment

    ERIC Educational Resources Information Center

    Murrie, Daniel C.; Boccaccini, Marcus T.; Caperton, Jennifer; Rufino, Katrina

    2012-01-01

    Several studies have concluded that scores from Hare's (2003) Psychopathy Checklist--Revised (PCL-R) predict reoffense among sexual offenders, but most of those studies examined the predictive validity of scores from trained research staff, not clinicians in the field scoring the measure as part of actual forensic assessments. Therefore, we…

  10. Psychometric properties of the Finnish version of the Women's Health Questionnaire.

    PubMed

    Katainen, Riina E; Engblom, Janne R; Vahlberg, Tero J; Polo-Kantola, Päivi

    2017-08-01

    The Women's Health Questionnaire (WHQ) is a validated and commonly used instrument for measuring climacteric-related symptoms. A revised version was previously developed. However, validation in a Finnish population is lacking. As it is important to use qualified instruments, we performed a validation study of the WHQ in a Finnish population. In all, 3,421 women, aged 41 to 54 years, formed the study population. In the original 36-item WHQ, the items were rated on a 1 to 4 scale and on a binary scale (0-1). The scaling of the revised 23-item WHQ was 0 to 100. We evaluated the psychometric properties (internal consistency, correlations between the symptom domains, factor structure, and sampling adequacy) in all three versions. For the 1 to 4 scale and on the revised version of the WHQ, the internal consistency was acceptable (the Cronbach's α coefficients >0.70) for most of the domains. On the binary scale, the majority of the coefficient values were below the acceptable level. The original symptom domains, especially those on the revised version, were recognizable from the factors in the exploratory factor analysis, but there were some limitations. The Kaiser-Meyer-Olkin values were high. The WHQ is a valid instrument for measuring climacteric-related symptoms in Finnish middle-aged women. The psychometric properties of the revised 23-item WHQ were as good or even better than those of the original 36-item WHQ. Thus, we encourage use of the revised version.

  11. Oxygen sensor signal validation for the safety of the rebreather diver.

    PubMed

    Sieber, Arne; L'abbate, Antonio; Bedini, Remo

    2009-03-01

    In electronically controlled, closed-circuit rebreather diving systems, the partial pressure of oxygen inside the breathing loop is controlled with three oxygen sensors, a microcontroller and a solenoid valve - critical components that may fail. State-of-the-art detection of sensor failure, based on a voting algorithm, may fail under circumstances where two or more sensors show the same but incorrect values. The present paper details a novel rebreather controller that offers true sensor-signal validation, thus allowing efficient and reliable detection of sensor failure. The core components of this validation system are two additional solenoids, which allow an injection of oxygen or diluent gas directly across the sensor membrane.

  12. Global trends in ocean phytoplankton: a new assessment using revised ocean colour data.

    PubMed

    Gregg, Watson W; Rousseaux, Cécile S; Franz, Bryan A

    2017-01-01

    A recent revision of the NASA global ocean colour record shows changes in global ocean chlorophyll trends. This new 18-year time series now includes three global satellite sensors, the Sea-viewing Wide Field of view Sensor (SeaWiFS), Moderate Resolution Imaging Spectroradiometer (MODIS-Aqua), and Visible Infrared Imaging Radiometer Suite (VIIRS). The major changes are radiometric drift correction, a new algorithm for chlorophyll, and a new sensor VIIRS. The new satellite data record shows no significant trend in global annual median chlorophyll from 1998 to 2015, in contrast to a statistically significant negative trend from 1998 to 2012 in the previous version. When revised satellite data are assimilated into a global ocean biogeochemical model, no trend is observed in global annual median chlorophyll. This is consistent with previous findings for the 1998-2012 time period using the previous processing version and only two sensors (SeaWiFS and MODIS). Detecting trends in ocean chlorophyll with satellites is sensitive to data processing options and radiometric drift correction. The assimilation of these data, however, reduces sensitivity to algorithms and radiometry, as well as the addition of a new sensor. This suggests the assimilation model has skill in detecting trends in global ocean colour. Using the assimilation model, spatial distributions of significant trends for the 18-year record (1998-2015) show recent decadal changes. Most notable are the North and Equatorial Indian Oceans basins, which exhibit a striking decline in chlorophyll. It is exemplified by declines in diatoms and chlorophytes, which in the model are large and intermediate size phytoplankton. This decline is partially compensated by significant increases in cyanobacteria, which represent very small phytoplankton. This suggests the beginning of a shift in phytoplankton composition in these tropical and subtropical Indian basins.

  13. Sensor sentinel computing device

    DOEpatents

    Damico, Joseph P.

    2016-08-02

    Technologies pertaining to authenticating data output by sensors in an industrial environment are described herein. A sensor sentinel computing device receives time-series data from a sensor by way of a wireline connection. The sensor sentinel computing device generates a validation signal that is a function of the time-series signal. The sensor sentinel computing device then transmits the validation signal to a programmable logic controller in the industrial environment.

  14. The revised scale for caregiving self-efficacy: reliability and validity studies.

    PubMed

    Steffen, Ann M; McKibbin, Christine; Zeiss, Antonette M; Gallagher-Thompson, Dolores; Bandura, Albert

    2002-01-01

    Two samples of family caregivers (Study 1: N = 169; Study 2: N = 145) of cognitively impaired older adults were used to revise, extend, and evaluate a measure of perceived self-efficacy for caregiving tasks. The Revised Scale for Caregiving Self-Efficacy measures 3 domains of caregiving self-efficacy: Obtaining Respite, Responding to Disruptive Patient Behaviors, and Controlling Upsetting Thoughts. The 3 subscales show strong internal consistency and adequate test-retest reliability. Construct validity is supported by relationships between these 3 facets of perceived caregiving efficacy and depression, anxiety, anger, perceived social support, and criticism expressed in speech samples. The Revised Scale for Caregiving Self-Efficacy has potential uses for both research and clinical purposes.

  15. Real-time sensor validation and fusion for distributed autonomous sensors

    NASA Astrophysics Data System (ADS)

    Yuan, Xiaojing; Li, Xiangshang; Buckles, Bill P.

    2004-04-01

    Multi-sensor data fusion has found widespread applications in industrial and research sectors. The purpose of real time multi-sensor data fusion is to dynamically estimate an improved system model from a set of different data sources, i.e., sensors. This paper presented a systematic and unified real time sensor validation and fusion framework (RTSVFF) based on distributed autonomous sensors. The RTSVFF is an open architecture which consists of four layers - the transaction layer, the process fusion layer, the control layer, and the planning layer. This paradigm facilitates distribution of intelligence to the sensor level and sharing of information among sensors, controllers, and other devices in the system. The openness of the architecture also provides a platform to test different sensor validation and fusion algorithms and thus facilitates the selection of near optimal algorithms for specific sensor fusion application. In the version of the model presented in this paper, confidence weighted averaging is employed to address the dynamic system state issue noted above. The state is computed using an adaptive estimator and dynamic validation curve for numeric data fusion and a robust diagnostic map for decision level qualitative fusion. The framework is then applied to automatic monitoring of a gas-turbine engine, including a performance comparison of the proposed real-time sensor fusion algorithms and a traditional numerical weighted average.

  16. Real-Time Sensor Validation, Signal Reconstruction, and Feature Detection for an RLV Propulsion Testbed

    NASA Technical Reports Server (NTRS)

    Jankovsky, Amy L.; Fulton, Christopher E.; Binder, Michael P.; Maul, William A., III; Meyer, Claudia M.

    1998-01-01

    A real-time system for validating sensor health has been developed in support of the reusable launch vehicle program. This system was designed for use in a propulsion testbed as part of an overall effort to improve the safety, diagnostic capability, and cost of operation of the testbed. The sensor validation system was designed and developed at the NASA Lewis Research Center and integrated into a propulsion checkout and control system as part of an industry-NASA partnership, led by Rockwell International for the Marshall Space Flight Center. The system includes modules for sensor validation, signal reconstruction, and feature detection and was designed to maximize portability to other applications. Review of test data from initial integration testing verified real-time operation and showed the system to perform correctly on both hard and soft sensor failure test cases. This paper discusses the design of the sensor validation and supporting modules developed at LeRC and reviews results obtained from initial test cases.

  17. Physics Metacognition Inventory Part II: Confirmatory factor analysis and Rasch analysis

    NASA Astrophysics Data System (ADS)

    Taasoobshirazi, Gita; Bailey, MarLynn; Farley, John

    2015-11-01

    The Physics Metacognition Inventory was developed to measure physics students' metacognition for problem solving. In one of our earlier studies, an exploratory factor analysis provided evidence of preliminary construct validity, revealing six components of students' metacognition when solving physics problems including knowledge of cognition, planning, monitoring, evaluation, debugging, and information management. The college students' scores on the inventory were found to be reliable and related to students' physics motivation and physics grade. However, the results of the exploratory factor analysis indicated that the questionnaire could be revised to improve its construct validity. The goal of this study was to revise the questionnaire and establish its construct validity through a confirmatory factor analysis. In addition, a Rasch analysis was applied to the data to better understand the psychometric properties of the inventory and to further evaluate the construct validity. Results indicated that the final, revised inventory is a valid, reliable, and efficient tool for assessing student metacognition for physics problem solving.

  18. The development and validation of using inertial sensors to monitor postural change in resistance exercise.

    PubMed

    Gleadhill, Sam; Lee, James Bruce; James, Daniel

    2016-05-03

    This research presented and validated a method of assessing postural changes during resistance exercise using inertial sensors. A simple lifting task was broken down to a series of well-defined tasks, which could be examined and measured in a controlled environment. The purpose of this research was to determine whether timing measures obtained from inertial sensor accelerometer outputs are able to provide accurate, quantifiable information of resistance exercise movement patterns. The aim was to complete a timing measure validation of inertial sensor outputs. Eleven participants completed five repetitions of 15 different deadlift variations. Participants were monitored with inertial sensors and an infrared three dimensional motion capture system. Validation was undertaken using a Will Hopkins Typical Error of the Estimate, with a Pearson׳s correlation and a Bland Altman Limits of Agreement analysis. Statistical validation measured the timing agreement during deadlifts, from inertial sensor outputs and the motion capture system. Timing validation results demonstrated a Pearson׳s correlation of 0.9997, with trivial standardised error (0.026) and standardised bias (0.002). Inertial sensors can now be used in practical settings with as much confidence as motion capture systems, for accelerometer timing measurements of resistance exercise. This research provides foundations for inertial sensors to be applied for qualitative activity recognition of resistance exercise and safe lifting practices. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. The Validity and Utility of the Positive Presentation Management and Negative Presentation Management Scales for the Revised NEO Personality Inventory

    ERIC Educational Resources Information Center

    Sellbom, Martin; Bagby, R. Michael

    2008-01-01

    Schinka, Kinder, and Kremer developed "validity" scales for the "Revised NEO Personality Inventory" (NEO PI-R; Costa & McCrae) to detect underreporting--the Positive Presentation Management (PPM) Scale and overreporting--the Negative Presentation Management (NPM) Scale. In this investigation, the clinical utility of these…

  20. The Bulimia Test--Revised: Validation with "DSM-IV" Criteria for Bulimia Nervosa.

    ERIC Educational Resources Information Center

    Thelen, Mark H.; And Others

    1996-01-01

    The Bulimia Test--Revised (BULIT-R) was given to 23 female subjects who met the criteria for bulimia in the "Diagnostic and Statistical Manual of Mental Disorders" (DSM-IV) and 124 female controls. The BULIT-R appears to be a valid instruction for identifying individuals who meet DSM-IV criteria for bulimia. (SLD)

  1. The Repetitive Behavior Scale-Revised: Independent Validation in Individuals with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Lam, Kristen S. L.; Aman, Michael G.

    2007-01-01

    A key feature of autism is restricted repetitive behavior (RRB). Despite the significance of RRBs, little is known about their phenomenology, assessment, and treatment. The Repetitive Behavior Scale-Revised (RBS-R) is a recently-developed questionnaire that captures the breadth of RRB in autism. To validate the RBS-R in an independent sample, we…

  2. Factorial Validity and Invariance Testing of the Exercise Dependence Scale-Revised in Swedish and Portuguese Exercisers

    ERIC Educational Resources Information Center

    Lindwall, Magnus; Palmeira, Antonio

    2009-01-01

    The present study investigated the factorial validity and factorial invariance of the 21-item Exercise Dependence Scale-Revised using 162 Swedish and 269 Portuguese exercisers. In addition, the prevalence of exercise dependence symptoms and links to exercise behavior, gender, and age in the two samples was also studied. Confirmatory factor…

  3. The Validity of the Psychopathic Personality Inventory-Revised in a Community Sample

    ERIC Educational Resources Information Center

    Uzieblo, Katarzyna; Verschuere, Bruno; Van den Bussche, Eva; Crombez, Geert

    2010-01-01

    Research on the Psychopathic Personality Inventory-Revised (PPI-R) has revealed two factors: Fearless Dominance, and Self-Centered Impulsivity. This study examined the validity of these PPI-R factors in a community sample (N = 675). First, confirmatory factor analyses did not support the two-factor structure. Second, the PPI-R factors showed good…

  4. Degree and Direction of Multiple Career Factors: Sex Differences and Construct Validity.

    ERIC Educational Resources Information Center

    Shaffer, Michal; And Others

    Personality, environment, and the interaction between them have been suggested as the major factors accounting for career development. Students (N=283) were asked to respond to 28 items on a recently revised self-report instrument, the Career Factor Checklist (CFC), in order to establish the construct validity of the revised CFC and to investigate…

  5. Validating the Thinking Styles Inventory-Revised II among Chinese University Students with Hearing Impairment through Test Accommodations

    ERIC Educational Resources Information Center

    Cheng, Sanyin; Zhang, Li-Fang

    2014-01-01

    The present study pioneered in adopting test accommodations to validate the Thinking Styles Inventory-Revised II (TSI-R2; Sternberg, Wagner, & Zhang, 2007) among Chinese university students with hearing impairment. A series of three studies were conducted that drew their samples from the same two universities, in which accommodating test…

  6. The revised Bristol Rheumatoid Arthritis Fatigue measures and the Rheumatoid Arthritis Impact of Disease scale: validation in six countries

    PubMed Central

    Kirwan, John; Bode, Christina; Cramp, Fiona; Carmona, Loreto; Dures, Emma; Englbrecht, Matthias; Fransen, Jaap; Greenwood, Rosemary; Hagel, Sofia; van de Laar, Maart; Molto, Anna; Nicklin, Joanna; Petersson, Ingemar F; Redondo, Marta; Schett, Georg; Gossec, Laure

    2018-01-01

    Abstract Objective To evaluate the Bristol Rheumatoid Arthritis Fatigue Multidimensional Questionnaire (BRAF-MDQ), the revised Bristol Rheumatoid Arthritis Numerical Rating Scales (BRAF-NRS V2) and the Rheumatoid Arthritis Impact of Disease (RAID) scale in six countries. Methods We surveyed RA patients in France, Germany, The Netherlands, Spain, Sweden and the UK, including the HAQ, 36-item Short Form Health Survey (SF-36) and potential revisions of the BRAF-NRS coping and Spanish RAID coping items. Factor structure and internal consistency were examined by factor analysis and Cronbach’s α and construct validity by Spearman’s correlation. Results A total of 1276 patients participated (76% female, 25% with a disease duration <5 years, median HAQ 1.0). The original BRAF-MDQ four-factor structure and RAID single-factor structure were confirmed in every country with ⩾66% of variation in items explained by each factor and all item factor loadings of 0.71–0.98. Internal consistency for the BRAF-MDQ total and subscales was a Cronbach’s α of 0.75–0.96 and for RAID, 0.93–0.96. Fatigue construct validity was shown for the BRAF-MDQ and BRAF-NRS severity and effect scales, correlated internally with SF-36 vitality and with RAID fatigue (r = 0.63–0.93). Broader construct validity for the BRAFs and RAID was shown by correlation with each other, HAQ and SF-36 domains (r = 0.46–0.82), with similar patterns in individual countries. The revised BRAF-NRS V2 Coping item had stronger validity than the original in all analyses. The revised Spanish RAID coping item performed as well as the original. Conclusion Across six European countries, the BRAF-MDQ identifies the same four aspects of fatigue, and along with the RAID, shows strong factor structure and internal consistency and moderate–good construct validity. The revised BRAF-NRS V2 shows improved construct validity and replaces the original. PMID:29087507

  7. The revised Bristol Rheumatoid Arthritis Fatigue measures and the Rheumatoid Arthritis Impact of Disease scale: validation in six countries.

    PubMed

    Hewlett, Sarah; Kirwan, John; Bode, Christina; Cramp, Fiona; Carmona, Loreto; Dures, Emma; Englbrecht, Matthias; Fransen, Jaap; Greenwood, Rosemary; Hagel, Sofia; van de Laar, Maart; Molto, Anna; Nicklin, Joanna; Petersson, Ingemar F; Redondo, Marta; Schett, Georg; Gossec, Laure

    2018-02-01

    To evaluate the Bristol Rheumatoid Arthritis Fatigue Multidimensional Questionnaire (BRAF-MDQ), the revised Bristol Rheumatoid Arthritis Numerical Rating Scales (BRAF-NRS V2) and the Rheumatoid Arthritis Impact of Disease (RAID) scale in six countries. We surveyed RA patients in France, Germany, The Netherlands, Spain, Sweden and the UK, including the HAQ, 36-item Short Form Health Survey (SF-36) and potential revisions of the BRAF-NRS coping and Spanish RAID coping items. Factor structure and internal consistency were examined by factor analysis and Cronbach's α and construct validity by Spearman's correlation. A total of 1276 patients participated (76% female, 25% with a disease duration <5 years, median HAQ 1.0). The original BRAF-MDQ four-factor structure and RAID single-factor structure were confirmed in every country with ⩾66% of variation in items explained by each factor and all item factor loadings of 0.71-0.98. Internal consistency for the BRAF-MDQ total and subscales was a Cronbach's α of 0.75-0.96 and for RAID, 0.93-0.96. Fatigue construct validity was shown for the BRAF-MDQ and BRAF-NRS severity and effect scales, correlated internally with SF-36 vitality and with RAID fatigue (r = 0.63-0.93). Broader construct validity for the BRAFs and RAID was shown by correlation with each other, HAQ and SF-36 domains (r = 0.46-0.82), with similar patterns in individual countries. The revised BRAF-NRS V2 Coping item had stronger validity than the original in all analyses. The revised Spanish RAID coping item performed as well as the original. Across six European countries, the BRAF-MDQ identifies the same four aspects of fatigue, and along with the RAID, shows strong factor structure and internal consistency and moderate-good construct validity. The revised BRAF-NRS V2 shows improved construct validity and replaces the original. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology.

  8. A catch-up validation study of an in vitro skin irritation test method using reconstructed human epidermis LabCyte EPI-MODEL24.

    PubMed

    Kojima, Hajime; Katoh, Masakazu; Shinoda, Shinsuke; Hagiwara, Saori; Suzuki, Tamie; Izumi, Runa; Yamaguchi, Yoshihiro; Nakamura, Maki; Kasahawa, Toshihiko; Shibai, Aya

    2014-07-01

    Three validation studies were conducted by the Japanese Society for Alternatives to Animal Experiments in order to assess the performance of a skin irritation assay using reconstructed human epidermis (RhE) LabCyte EPI-MODEL24 (LabCyte EPI-MODEL24 SIT) developed by the Japan Tissue Engineering Co., Ltd. (J-TEC), and the results of these studies were submitted to the Organisation for Economic Co-operation and Development (OECD) for the creation of a Test Guideline (TG). In the summary review report from the OECD, the peer review panel indicated the need to resolve an issue regarding the misclassification of 1-bromohexane. To this end, a rinsing operation intended to remove exposed chemicals was reviewed and the standard operating procedure (SOP) revised by J-TEC. Thereafter, in order to confirm general versatility of the revised SOP, a new validation management team was organized by the Japanese Center for the Validation of Alternative Methods (JaCVAM) to undertake a catch-up validation study that would compare the revised assay with similar in vitro skin irritation assays, per OECD TG No. 439 (2010). The catch-up validation and supplementary studies for LabCyte EPI-MODEL24 SIT using the revised SOPs were conducted at three laboratories. These results showed that the revised SOP of LabCyte EPI-MODEL24 SIT conformed more accurately to the classifications for skin irritation under the United Nations Globally Harmonised System of Classification and Labelling of Chemicals (UN GHS), thereby highlighting the importance of an optimized rinsing operation for the removal of exposed chemicals in obtaining consistent results from in vitro skin irritation assays. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Modeling and simulation of soft sensor design for real-time speed estimation, measurement and control of induction motor.

    PubMed

    Etien, Erik

    2013-05-01

    This paper deals with the design of a speed soft sensor for induction motor. The sensor is based on the physical model of the motor. Because the validation step highlight the fact that the sensor cannot be validated for all the operating points, the model is modified in order to obtain a fully validated sensor in the whole speed range. An original feature of the proposed approach is that the modified model is derived from stability analysis using automatic control theory. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, Levente

    Interpreting sensor data require knowledge about sensor placement and the surrounding environment. For a single sensor measurement, it is easy to document the context by visual observation, however for millions of sensors reporting data back to a server, the contextual information needs to be automatically extracted from either data analysis or leveraging complimentary data sources. Data layers that overlap spatially or temporally with sensor locations, can be used to extract the context and to validate the measurement. To minimize the amount of data transmitted through the internet, while preserving signal information content, two methods are explored; computation at the edgemore » and compressed sensing. We validate the above methods on wind and chemical sensor data (1) eliminate redundant measurement from wind sensors and (2) extract peak value of a chemical sensor measuring a methane plume. We present a general cloud based framework to validate sensor data based on statistical and physical modeling and contextual data extracted from geospatial data.« less

  11. Real-Time Sensor Validation System Developed for Reusable Launch Vehicle Testbed

    NASA Technical Reports Server (NTRS)

    Jankovsky, Amy L.

    1997-01-01

    A real-time system for validating sensor health has been developed for the reusable launch vehicle (RLV) program. This system, which is part of the propulsion checkout and control system (PCCS), was designed for use in an integrated propulsion technology demonstrator testbed built by Rockwell International and located at the NASA Marshall Space Flight Center. Work on the sensor health validation system, a result of an industry-NASA partnership, was completed at the NASA Lewis Research Center, then delivered to Marshall for integration and testing. The sensor validation software performs three basic functions: it identifies failed sensors, it provides reconstructed signals for failed sensors, and it identifies off-nominal system transient behavior that cannot be attributed to a failed sensor. The code is initiated by host software before the start of a propulsion system test, and it is called by the host program every control cycle. The output is posted to global memory for use by other PCCS modules. Output includes a list indicating the status of each sensor (i.e., failed, healthy, or reconstructed) and a list of features that are not due to a sensor failure. If a sensor failure is found, the system modifies that sensor's data array by substituting a reconstructed signal, when possible, for use by other PCCS modules.

  12. A Comparison of Reliability and Construct Validity between the Original and Revised Versions of the Rosenberg Self-Esteem Scale

    PubMed Central

    Nahathai, Wongpakaran

    2012-01-01

    Objective The Rosenberg Self-Esteem Scale (RSES) is a widely used instrument that has been tested for reliability and validity in many settings; however, some negative-worded items appear to have caused it to reveal low reliability in a number of studies. In this study, we revised one negative item that had previously (from the previous studies) produced the worst outcome in terms of the structure of the scale, then re-analyzed the new version for its reliability and construct validity, comparing it to the original version with respect to fit indices. Methods In total, 851 students from Chiang Mai University (mean age: 19.51±1.7, 57% of whom were female), participated in this study. Of these, 664 students completed the Thai version of the original RSES - containing five positively worded and five negatively worded items, while 187 students used the revised version containing six positively worded and four negatively worded items. Confirmatory factor analysis was applied, using a uni-dimensional model with method effects and a correlated uniqueness approach. Results The revised version showed the same level of reliability (good) as the original, but yielded a better model fit. The revised RSES demonstrated excellent fit statistics, with χ2=29.19 (df=19, n=187, p=0.063), GFI=0.970, TFI=0.969, NFI=0.964, CFI=0.987, SRMR=0.040 and RMSEA=0.054. Conclusion The revised version of the Thai RSES demonstrated an equivalent level of reliability but a better construct validity when compared to the original. PMID:22396685

  13. A comparison of reliability and construct validity between the original and revised versions of the Rosenberg Self-Esteem Scale.

    PubMed

    Wongpakaran, Tinakon; Tinakon, Wongpakaran; Wongpakaran, Nahathai; Nahathai, Wongpakaran

    2012-03-01

    The Rosenberg Self-Esteem Scale (RSES) is a widely used instrument that has been tested for reliability and validity in many settings; however, some negative-worded items appear to have caused it to reveal low reliability in a number of studies. In this study, we revised one negative item that had previously (from the previous studies) produced the worst outcome in terms of the structure of the scale, then re-analyzed the new version for its reliability and construct validity, comparing it to the original version with respect to fit indices. In total, 851 students from Chiang Mai University (mean age: 19.51±1.7, 57% of whom were female), participated in this study. Of these, 664 students completed the Thai version of the original RSES - containing five positively worded and five negatively worded items, while 187 students used the revised version containing six positively worded and four negatively worded items. Confirmatory factor analysis was applied, using a uni-dimensional model with method effects and a correlated uniqueness approach. The revised version showed the same level of reliability (good) as the original, but yielded a better model fit. The revised RSES demonstrated excellent fit statistics, with χ²=29.19 (df=19, n=187, p=0.063), GFI=0.970, TFI=0.969, NFI=0.964, CFI=0.987, SRMR=0.040 and RMSEA=0.054. The revised version of the Thai RSES demonstrated an equivalent level of reliability but a better construct validity when compared to the original.

  14. Sensor of total hip arthoplasty wear designed on principle of scanning profilometry

    NASA Astrophysics Data System (ADS)

    Rössler, Tomas; Mandat, Dusan; Gallo, Jiri; Hrabovsky, Miroslav; Pochmon, Michal; Havranek, Vitezslav

    2008-12-01

    Total hip arthroplasty significantly improves the quality of life in majority of patients with osteoarthritis. However, prosthetic wear is a problem because of inducing the development of aseptic loosening and periprosthetic osteolysis which needs the revision surgery. Thus, the polyethylene wear measurement is the central to contemporary orthopaedics and this interesting has encouraged the development and improvement of both radiologic (in vivo) and non-radiologic (in vitro) methods for polyethylene wear quantification. The principles of polyethylene liner wear measurements are predominantly geometric; nevertheless, the realization of individual types of in vivo measurements brings with it the necessity of many simplifications and compromising steps to acquire approximately accurate values. In fact, the volumetric wear can be obtained by mathematical conversion based on the most linear shift of femoral head in the cup. However, such approach is understood to be somewhat insufficient. Our ongoing research pointed to the development of optical non-contact method for wear measurement and its results are introduced in this paper including the methodology designed for the usability validation of the method for the given purpose and the description of sensor, its principle, technical realization, design and parameters.

  15. Construct Validation of the Self-Efficacy Teaching and Knowledge Instrument for Science Teachers-Revised (SETAKIST-R): Lessons Learned

    ERIC Educational Resources Information Center

    Pruski, Linda A.; Blanco, Sharon L.; Riggs, Rosemary A.; Grimes, Kandi K.; Fordtran, Chase W.; Barbola, Gina M.; Cornell, John E.; Lichtenstein, Michael J.

    2013-01-01

    Described herein is the academic lineage and independent validation of the Self-Efficacy Teaching and Knowledge Instrument for Science Teachers-Revised (SETAKIST-R). Data from 334 K-12 science teachers were analyzed using Partial Credit Rasch models. Principal components analysis on the person-item residuals suggest two latent dimensions:…

  16. The Personality Assessment Inventory as a Proxy for the Psychopathy Checklist-Revised: Testing the Incremental Validity and Cross-Sample Robustness of the Antisocial Features Scale

    ERIC Educational Resources Information Center

    Douglas, Kevin S.; Guy, Laura S.; Edens, John F.; Boer, Douglas P.; Hamilton, Jennine

    2007-01-01

    The Personality Assessment Inventory's (PAI's) ability to predict psychopathic personality features, as assessed by the Psychopathy Checklist-Revised (PCL-R), was examined. To investigate whether the PAI Antisocial Features (ANT) Scale and subscales possessed incremental validity beyond other theoretically relevant PAI scales, optimized regression…

  17. Real-time sensor data validation

    NASA Technical Reports Server (NTRS)

    Bickmore, Timothy W.

    1994-01-01

    This report describes the status of an on-going effort to develop software capable of detecting sensor failures on rocket engines in real time. This software could be used in a rocket engine controller to prevent the erroneous shutdown of an engine due to sensor failures which would otherwise be interpreted as engine failures by the control software. The approach taken combines analytical redundancy with Bayesian belief networks to provide a solution which has well defined real-time characteristics and well-defined error rates. Analytical redundancy is a technique in which a sensor's value is predicted by using values from other sensors and known or empirically derived mathematical relations. A set of sensors and a set of relations among them form a network of cross-checks which can be used to periodically validate all of the sensors in the network. Bayesian belief networks provide a method of determining if each of the sensors in the network is valid, given the results of the cross-checks. This approach has been successfully demonstrated on the Technology Test Bed Engine at the NASA Marshall Space Flight Center. Current efforts are focused on extending the system to provide a validation capability for 100 sensors on the Space Shuttle Main Engine.

  18. Validation of the Andon KD-5851 upper arm blood pressure monitor, for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Wu, Lili; Jiao, Yinghui; Wang, Chengdong; Chen, Lei; Di, Dalin; Zhang, Haiyan

    2015-08-01

    This study aimed to validate the Andon KD-5851 upper arm blood pressure (BP) monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 33 eligible participants were included in the study. Sequential measurements of BPs were performed using a mercury sphygmomanometer and the device, and the data analysis was carried out following precisely the ESH-IP revision 2010. The device had 82, 98, and 99 measurements within 5, 10, and 15 mmHg for systolic blood pressure and 85, 95, and 99 measurements for diastolic blood pressure, respectively. The average device-observer difference was -0.53±4.00 mmHg for systolic blood pressure and -1.15±4.06 mmHg for diastolic blood pressure. The device passed all the criteria according to the ESH-IP revision 2010. According to the validation results on the basis of the ESH-IP revision 2010, the Andon KD-5851 upper arm BP monitor can be recommended for self/home measurement in adults. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.

  19. EDGE COMPUTING AND CONTEXTUAL INFORMATION FOR THE INTERNET OF THINGS SENSORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, Levente

    Interpreting sensor data require knowledge about sensor placement and the surrounding environment. For a single sensor measurement, it is easy to document the context by visual observation, however for millions of sensors reporting data back to a server, the contextual information needs to be automatically extracted from either data analysis or leveraging complimentary data sources. Data layers that overlap spatially or temporally with sensor locations, can be used to extract the context and to validate the measurement. To minimize the amount of data transmitted through the internet, while preserving signal information content, two methods are explored; computation at the edgemore » and compressed sensing. We validate the above methods on wind and chemical sensor data (1) eliminate redundant measurement from wind sensors and (2) extract peak value of a chemical sensor measuring a methane plume. We present a general cloud based framework to validate sensor data based on statistical and physical modeling and contextual data extracted from geospatial data.« less

  20. The revised Generalized Expectancy for Success Scale: a validity and reliability study.

    PubMed

    Hale, W D; Fiedler, L R; Cochran, C D

    1992-07-01

    The Generalized Expectancy for Success Scale (GESS; Fibel & Hale, 1978) was revised and assessed for reliability and validity. The revised version was administered to 199 college students along with other conceptually related measures, including the Rosenberg Self-Esteem Scale, the Life Orientation Test, and Rotter's Internal-External Locus of Control Scale. One subsample of students also completed the Eysenck Personality Inventory, while another subsample performed a criterion-related task that involved risk taking. Item analysis yielded 25 items with correlations of .45 or higher with the total score. Results indicated high internal consistency and test-retest reliability.

  1. Validation of a clinical critical thinking skills test in nursing.

    PubMed

    Shin, Sujin; Jung, Dukyoo; Kim, Sungeun

    2015-01-27

    The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability.

  2. Validation of a clinical critical thinking skills test in nursing

    PubMed Central

    2015-01-01

    Purpose: The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. Methods: This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Results: Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. Conclusion: From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability. PMID:25622716

  3. [Columbia Sensor Diagrams]. Revised

    NASA Technical Reports Server (NTRS)

    2003-01-01

    A two dimensional graphical event sequence of the time history of relevant sensor information located in the left wing and wheel well areas of the Space Shuttle Columbia Orbiter is presented. Information contained in this graphical event sequence include: 1) Sensor location on orbiter and its associated wire bindle in X-Y plane; 2) Wire bundle routing; 3) Description of each anomalous sensor event; 4) Time annotation by (a) GMT, (b) time relative to LOS, (c) time history bar, and (d) ground track; and 5) Graphical display of temperature rise (based on delta temperature from point it is determined to be anomalous).

  4. What Is High School Economics? TEL Revision and Pretest Findings.

    ERIC Educational Resources Information Center

    Walstad, William B.; Soper, John C.

    1988-01-01

    Argues there is limited research data about student knowledge of economic concepts at the secondary school education level. Describes the development, validation, and national norming of the revised Test of Economic Literacy (TEL) and presents findings from the 1986 pretest analysis of the revised TEL. (BSR)

  5. Comparison of Wells and Revised Geneva Rule to Assess Pretest Probability of Pulmonary Embolism in High-Risk Hospitalized Elderly Adults.

    PubMed

    Di Marca, Salvatore; Cilia, Chiara; Campagna, Andrea; D'Arrigo, Graziella; Abd ElHafeez, Samar; Tripepi, Giovanni; Puccia, Giuseppe; Pisano, Marcella; Mastrosimone, Gianluca; Terranova, Valentina; Cardella, Antonella; Buonacera, Agata; Stancanelli, Benedetta; Zoccali, Carmine; Malatino, Lorenzo

    2015-06-01

    To assess and compare the diagnostic power for pulmonary embolism (PE) of Wells and revised Geneva scores in two independent cohorts (training and validation groups) of elderly adults hospitalized in a non-emergency department. Prospective clinical study, January 2011 to January 2013. Unit of Internal Medicine inpatients, University of Catania, Italy. Elderly adults (mean age 76 ± 12), presenting with dyspnea or chest pain and with high clinical probability of PE or D-dimer values greater than 500 ng/mL (N = 203), were enrolled and consecutively assigned to a training (n = 101) or a validation (n = 102) group. The clinical probability of PE was assessed using Wells and revised Geneva scores. Clinical examination, D-dimer test, and multidetector computed angiotomography were performed in all participants. The accuracy of the scores was assessed using receiver operating characteristic analyses. PE was confirmed in 46 participants (23%) (24 training group, 22 validation group). In the training group, the area under the receiver operating characteristic curve was 0.91 (95% confidence interval (CI) = 0.85-0.98) for the Wells score and 0.69 (95% CI = 0.56-0.82) for the revised Geneva score (P < .001). These results were confirmed in the validation group (P < .05). The positive (LR+) and negative likelihood ratios (LR-) (two indices combining sensitivity and specificity) of the Wells score were superior to those of the revised Geneva score in the training (LR+, 7.90 vs 1.34; LR-, 0.23 vs 0.66) and validation (LR+, 13.5 vs 1.46; LR-, 0.47 vs 0.54) groups. In high-risk elderly hospitalized adults, the Wells score is more accurate than the revised Geneva score for diagnosing PE. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.

  6. Survey of Collision Avoidance and Ranging Sensors for Mobile Robots. Revision 1

    DTIC Science & Technology

    1992-12-01

    diagram of the Hamamatsu’s Range-Finder Chip Set, which applies the principle of triangulation (Hamamatsu Corporation, 1990) ....................... 37...platform (Courtesy Transitions Research Company ) . ............................................ 68 37. The Sensus 300 configured for 360-degree coverage... applied to the detection of metal objects located at short-range. Typical inductive sensors generate an oscillatory radio-frequency (RF) field around a

  7. Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Yi, Jun; Wan, Yi; Pan, Feng; Yu, Xiaorong; Zhao, Huadong; Shang, Fujun; Xu, Yongyong

    2011-08-01

    The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. A total of 99 couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The device produced 73, 93, and 98 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 79, 93, and 96 for diastolic blood pressure (DBP), respectively. The mean standard deviation device-observer difference was 1.4 ± 5.2 mmHg for SBP and 0.02±5.8 mmHg for DBP. The number of participants with two or three of the device-observer differences within 5 mmHg was 24 for SBP and 30 for DBP, whereas there was no participant with none of the device-observer differences within 5 mmHg. According to the results of the validation study based on the ESH-IP revision 2010, the Medipro MediCare 100f can be recommended for self-measurement in an adult population.

  8. Convergent Validity of the Autism Spectrum Disorder-Diagnostic for Children (ASD-DC) and Autism Diagnostic Interview-Revised (ADI-R)

    ERIC Educational Resources Information Center

    Matson, Johnny L.; Hess, Julie A.; Mahan, Sara; Fodstad, Jill C.

    2010-01-01

    The purpose of this paper was to further establish the validity of the Autism Spectrum Disorder-Diagnostic for Children (ASD-DC). The methodology consisted of testing the similarity of findings between the ASD-DC and the Autism Diagnostic Interview-Revised (ADI-R), which proved to be statistically significant for subscale content scores on social,…

  9. Rasch Modeling of Revised Token Test Performance: Validity and Sensitivity to Change

    ERIC Educational Resources Information Center

    Hula, William; Doyle, Patrick J.; McNeil, Malcolm R.; Mikolic, Joseph M.

    2006-01-01

    The purpose of this research was to examine the validity of the 55-item Revised Token Test (RTT) and to compare traditional and Rasch-based scores in their ability to detect group differences and change over time. The 55-item RTT was administered to 108 left- and right-hemisphere stroke survivors, and the data were submitted to Rasch analysis.…

  10. Reliability and Validity of the Computerized Revised Token Test: Comparison of Reading and Listening Versions in Persons with and without Aphasia

    ERIC Educational Resources Information Center

    McNeil, Malcolm R.; Pratt, Sheila R.; Szuminsky, Neil; Sung, Jee Eun; Fossett, Tepanta R. D.; Fassbinder, Wiltrud; Lim, Kyoung Yuel

    2015-01-01

    Purpose: This study assessed the reliability and validity of intermodality associations and differences in persons with aphasia (PWA) and healthy controls (HC) on a computerized listening and 3 reading versions of the Revised Token Test (RTT; McNeil & Prescott, 1978). Method: Thirty PWA and 30 HC completed the test versions, including a…

  11. Short Forms of the Wechsler Memory Scale--Revised: Cross- Validation and Derivation of a Two-Subtest Form.

    ERIC Educational Resources Information Center

    van den Broek, Anneke; Golden, Charles J.; Loonstra, Ann; Ghinglia, Katheryne; Goldstein, Diane

    1998-01-01

    Indicated excellent cross-validations with correlation of 0.99 for past formulas (J. L. Woodard and B. N. Axelrod, 1995; B. N. Axelrod et al, 1996) for estimating the Wechsler Memory Scale- Revised General Memory and Delayed Recall Indexes. Over 85% of the estimated scores were within 10 points of actual scores. Age, education, diagnosis, and IQ…

  12. Adapting CEF-Descriptors for Rating Purposes: Validation by a Combined Rater Training and Scale Revision Approach

    ERIC Educational Resources Information Center

    Harsch, Claudia; Martin, Guido

    2012-01-01

    We explore how a local rating scale can be based on the Common European Framework CEF-proficiency scales. As part of the scale validation (Alderson, 1991; Lumley, 2002), we examine which adaptations are needed to turn CEF-proficiency descriptors into a rating scale for a local context, and to establish a practicable method to revise the initial…

  13. A Chinese version of the revised Nurses Professional Values Scale: reliability and validity assessment.

    PubMed

    Lin, Yu-Hua; Wang, Liching Sung

    2010-08-01

    The purpose of this study was to assess the reliability and validity of a Chinese version of the revised nurses professional values scale (NPVS-R). The convenient sampling method, including senior undergraduate nursing students (n=110) and clinical nurses (n=223), was applied to recruit appropriate samples from southern Taiwan. The revised nurses professional values scale (NPVS-R) was used in this study. Content validity, construct validity, internal consistency, and reliability were assessed. The final sample consisted of 286 subjects. three factors were detected in the results, accounting for 60.12% of the explained variance. The first factor was titled professionalism, and included 13 items. The second factor was named caring, and consisted of seven items. Activism was the third factor, which included six items. Overall Cronbach's alpha coefficient was 0.90, taken from values for each of the three factors of 0.88, 0.90, and 0.81, respectively. The Chinese version of the NPVS-R can be considered a reliable and valid scale for assigning values that can mark professionalism in Taiwanese nurses. Copyright 2009 Elsevier Ltd. All rights reserved.

  14. Validation of a global scale to assess the quality of interprofessional teamwork in mental health settings.

    PubMed

    Tomizawa, Ryoko; Yamano, Mayumi; Osako, Mitue; Hirabayashi, Naotugu; Oshima, Nobuo; Sigeta, Masahiro; Reeves, Scott

    2017-12-01

    Few scales currently exist to assess the quality of interprofessional teamwork through team members' perceptions of working together in mental health settings. The purpose of this study was to revise and validate an interprofessional scale to assess the quality of teamwork in inpatient psychiatric units and to use it multi-nationally. A literature review was undertaken to identify evaluative teamwork tools and develop an additional 12 items to ensure a broad global focus. Focus group discussions considered adaptation to different care systems using subjective judgements from 11 participants in a pre-test of items. Data quality, construct validity, reproducibility, and internal consistency were investigated in the survey using an international comparative design. Exploratory factor analysis yielded five factors with 21 items: 'patient/community centred care', 'collaborative communication', 'interprofessional conflict', 'role clarification', and 'environment'. High overall internal consistency, reproducibility, adequate face validity, and reasonable construct validity were shown in the USA and Japan. The revised Collaborative Practice Assessment Tool (CPAT) is a valid measure to assess the quality of interprofessional teamwork in psychiatry and identifies the best strategies to improve team performance. Furthermore, the revised scale will generate more rigorous evidence for collaborative practice in psychiatry internationally.

  15. Translation, adaptation, and validation of the Sunderland Scale and the Cubbin & Jackson Revised Scale in Portuguese

    PubMed Central

    Sousa, Bruno

    2013-01-01

    Objective To translate into Portuguese and evaluate the measuring properties of the Sunderland Scale and the Cubbin & Jackson Revised Scale, which are instruments for evaluating the risk of developing pressure ulcers during intensive care. Methods This study included the process of translation and adaptation of the scales to the Portuguese language, as well as the validation of these tools. To assess the reliability, Cronbach alpha values of 0.702 to 0.708 were identified for the Sunderland Scale and the Cubbin & Jackson Revised Scale, respectively. The validation criteria (predictive) were performed comparatively with the Braden Scale (gold standard), and the main measurements evaluated were sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve, which were calculated based on cutoff points. Results The Sunderland Scale exhibited 60% sensitivity, 86.7% specificity, 47.4% positive predictive value, 91.5% negative predictive value, and 0.86 for the area under the curve. The Cubbin & Jackson Revised Scale exhibited 73.3% sensitivity, 86.7% specificity, 52.4% positive predictive value, 94.2% negative predictive value, and 0.91 for the area under the curve. The Braden scale exhibited 100% sensitivity, 5.3% specificity, 17.4% positive predictive value, 100% negative predictive value, and 0.72 for the area under the curve. Conclusions Both tools demonstrated reliability and validity for this sample. The Cubbin & Jackson Revised Scale yielded better predictive values for the development of pressure ulcers during intensive care. PMID:23917975

  16. Evaluation of passenger health risk assessment of sustainable indoor air quality monitoring in metro systems based on a non-Gaussian dynamic sensor validation method.

    PubMed

    Kim, MinJeong; Liu, Hongbin; Kim, Jeong Tai; Yoo, ChangKyoo

    2014-08-15

    Sensor faults in metro systems provide incorrect information to indoor air quality (IAQ) ventilation systems, resulting in the miss-operation of ventilation systems and adverse effects on passenger health. In this study, a new sensor validation method is proposed to (1) detect, identify and repair sensor faults and (2) evaluate the influence of sensor reliability on passenger health risk. To address the dynamic non-Gaussianity problem of IAQ data, dynamic independent component analysis (DICA) is used. To detect and identify sensor faults, the DICA-based squared prediction error and sensor validity index are used, respectively. To restore the faults to normal measurements, a DICA-based iterative reconstruction algorithm is proposed. The comprehensive indoor air-quality index (CIAI) that evaluates the influence of the current IAQ on passenger health is then compared using the faulty and reconstructed IAQ data sets. Experimental results from a metro station showed that the DICA-based method can produce an improved IAQ level in the metro station and reduce passenger health risk since it more accurately validates sensor faults than do conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Development and Ground-Test Validation of Fiber Optic Sensor Attachment Techniques for Hot Structures Applications

    NASA Technical Reports Server (NTRS)

    Piazza, Anthony; Hudson, Larry D.; Richards, W. Lance

    2005-01-01

    Fiber Optic Strain Measurements: a) Successfully attached silica fiber optic sensors to both metallics and composites; b) Accomplished valid EFPI strain measurements to 1850 F; c) Successfully attached EFPI sensors to large scale hot-structures; and d) Attached and thermally validated FBG bond and epsilon(sub app). Future Development a) Improve characterization of sensors on C-C and C-SiC substrates; b) Apply application to other composites such as SiC-SiC; c) Assist development of interferometer based Sapphire sensor currently being conducted under a Phase II SBIR; and d) Complete combined thermal/mechanical testing of FBG on composite substrates in controlled laboratory environment.

  18. Convergent validity of alternative MMPI-2 personality disorder scales.

    PubMed

    Hicklin, J; Widiger, T A

    2000-12-01

    The Morey, Waugh, and Blashfield (1985) MMPI (Hathaway et al., 1989) personality disorder scales provided a significant contribution to personality disorder research and assessment. However, the subsequent revisions to the MMPI and the multiple revisions to the diagnostic criteria sets that have since occurred may have justified comparable revisions to these scales. Somwaru and Ben-Porath (1995) selected a substantially different set of items from the MMPI-2 (Butcher, Dahlstrom, Graham, Tellegen, & Kaemmer, 1989) to assess Diagnostic and Statistical Manual of Mental Disorders (4th ed.; American Psychiatric Association, 1994) personality disorder diagnostic criteria. In our study, we compared the convergent validity of these alternative MMPI-2 personality disorder scales with respect to 3 self-report measures of personality disorder symptomatology in a sample of 82 psychiatric outpatients. The results suggested that Somwaru and Ben-Porath's scales are as valid as the original Morey et al. scales and might be even more valid for the assessment of borderline, antisocial, and schizoid personality disorder symptomatology.

  19. The Relationship between the Woodcock-Johnson Psycho-Educational Battery-Revised (Early Development) and the Wechsler Preschool and Primary Scale of Intelligence-Revised.

    ERIC Educational Resources Information Center

    Harrington, Robert G.; And Others

    1992-01-01

    Examined concurrent validity between Woodcock-Johnson Psycho-Educational Battery-Revised Tests of Cognitive Ability (WJ-R, COG) (Early Development) and Wechsler Preschool and Primary Scale of Intelligence-Revised (WPPSI-R) by administering instruments to 30 normal 3, 4, and 5 year olds. WJ-R Broad Cognitive Ability and WPPSI-R Full Scale IQ and…

  20. DEC Personnel Preparation Standards: Revision 2005-2008

    ERIC Educational Resources Information Center

    Lifter, Karin; Chandler, Lynette K.; Cochran, Deborah C.; Dinnebeil, Laurie A.; Gallagher, Peggy A.; Christensen, Kimberly A.; Stayton, Vicki D.

    2011-01-01

    The revision and process of validation of standards for early childhood special education (ECSE) and early intervention (EI) personnel at the initial and advanced levels of preparation, which occurred during 2005-2008, are described to provide a record of the process and to inform future cycles of standards revision. Central components focus on…

  1. Validity and Reliability of Revised Inventory of Learning Processes.

    ERIC Educational Resources Information Center

    Gadzella, B. M.; And Others

    The Inventory of Learning Processes (ILP) was developed by Schmeck, Ribich, and Ramanaiah in 1977 as a self-report inventory to assess learning style through a behavioral-oriented approach. The ILP was revised by Schmeck in 1983. The Revised ILP contains six scales: (1) Deep Processing; (2) Elaborative Processing; (3) Shallow Processing; (4)…

  2. ARINC 818 specification revisions enable new avionics architectures

    NASA Astrophysics Data System (ADS)

    Grunwald, Paul

    2014-06-01

    The ARINC 818 Avionics Digital Video Bus is the standard for cockpit video that has gained wide acceptance in both the commercial and military cockpits. The Boeing 787, A350XWB, A400M, KC-46A, and many other aircraft use it. The ARINC 818 specification, which was initially release in 2006, has recently undergone a major update to address new avionics architectures and capabilities. Over the seven years since its release, projects have gone beyond the specification due to the complexity of new architectures and desired capabilities, such as video switching, bi-directional communication, data-only paths, and camera and sensor control provisions. The ARINC 818 specification was revised in 2013, and ARINC 818-2 was approved in November 2013. The revisions to the ARINC 818-2 specification enable switching, stereo and 3-D provisions, color sequential implementations, regions of interest, bi-directional communication, higher link rates, data-only transmission, and synchronization signals. This paper discusses each of the new capabilities and the impact on avionics and display architectures, especially when integrating large area displays, stereoscopic displays, multiple displays, and systems that include a large number of sensors.

  3. Revision of IRIS/IDA Seismic Station Metadata

    NASA Astrophysics Data System (ADS)

    Xu, W.; Davis, P.; Auerbach, D.; Klimczak, E.

    2017-12-01

    Trustworthy data quality assurance has always been one of the goals of seismic network operators and data management centers. This task is considerably complex and evolving due to the huge quantities as well as the rapidly changing characteristics and complexities of seismic data. Published metadata usually reflect instrument response characteristics and their accuracies, which includes zero frequency sensitivity for both seismometer and data logger as well as other, frequency-dependent elements. In this work, we are mainly focused studying the variation of the seismometer sensitivity with time of IRIS/IDA seismic recording systems with a goal to improve the metadata accuracy for the history of the network. There are several ways to measure the accuracy of seismometer sensitivity for the seismic stations in service. An effective practice recently developed is to collocate a reference seismometer in proximity to verify the in-situ sensors' calibration. For those stations with a secondary broadband seismometer, IRIS' MUSTANG metric computation system introduced a transfer function metric to reflect two sensors' gain ratios in the microseism frequency band. In addition, a simulation approach based on M2 tidal measurements has been proposed and proven to be effective. In this work, we compare and analyze the results from three different methods, and concluded that the collocated-sensor method is most stable and reliable with the minimum uncertainties all the time. However, for epochs without both the collocated sensor and secondary seismometer, we rely on the analysis results from tide method. For the data since 1992 on IDA stations, we computed over 600 revised seismometer sensitivities for all the IRIS/IDA network calibration epochs. Hopefully further revision procedures will help to guarantee that the data is accurately reflected by the metadata of these stations.

  4. Optimal Sensor Allocation for Fault Detection and Isolation

    NASA Technical Reports Server (NTRS)

    Azam, Mohammad; Pattipati, Krishna; Patterson-Hine, Ann

    2004-01-01

    Automatic fault diagnostic schemes rely on various types of sensors (e.g., temperature, pressure, vibration, etc) to measure the system parameters. Efficacy of a diagnostic scheme is largely dependent on the amount and quality of information available from these sensors. The reliability of sensors, as well as the weight, volume, power, and cost constraints, often makes it impractical to monitor a large number of system parameters. An optimized sensor allocation that maximizes the fault diagnosibility, subject to specified weight, volume, power, and cost constraints is required. Use of optimal sensor allocation strategies during the design phase can ensure better diagnostics at a reduced cost for a system incorporating a high degree of built-in testing. In this paper, we propose an approach that employs multiple fault diagnosis (MFD) and optimization techniques for optimal sensor placement for fault detection and isolation (FDI) in complex systems. Keywords: sensor allocation, multiple fault diagnosis, Lagrangian relaxation, approximate belief revision, multidimensional knapsack problem.

  5. Hubble Space Telescope Fine Guidance Sensors Instrument Handbook, version 4.0

    NASA Technical Reports Server (NTRS)

    Holfeltz, S. T. (Editor)

    1994-01-01

    This is a revised version of the Hubble Space Telescope Fine Guidance Sensor Instrument Handbook. The main goal of this edition is to help the potential General Observer (GO) learn how to most efficiently use the Fine Guidance Sensors (FGS's). First, the actual performance of the FGS's as scientific instruments is reviewed. Next, each of the available operating modes of the FGS's are reviewed in turn. The status and findings of pertinent calibrations, including Orbital Verification, Science Verification, and Instrument Scientist Calibrations are included as well as the relevant data reduction software.

  6. Demonstration of automated proximity and docking technologies

    NASA Astrophysics Data System (ADS)

    Anderson, Robert L.; Tsugawa, Roy K.; Bryan, Thomas C.

    An autodock was demonstrated using straightforward techniques and real sensor hardware. A simulation testbed was established and validated. The sensor design was refined with improved optical performance and image processing noise mitigation techniques, and the sensor is ready for production from off-the-shelf components. The autonomous spacecraft architecture is defined. The areas of sensors, docking hardware, propulsion, and avionics are included in the design. The Guidance Navigation and Control architecture and requirements are developed. Modular structures suitable for automated control are used. The spacecraft system manager functions including configuration, resource, and redundancy management are defined. The requirements for autonomous spacecraft executive are defined. High level decisionmaking, mission planning, and mission contingency recovery are a part of this. The next step is to do flight demonstrations. After the presentation the following question was asked. How do you define validation? There are two components to validation definition: software simulation with formal and vigorous validation, and hardware and facility performance validated with respect to software already validated against analytical profile.

  7. Comparison of African American Children's Performances on a Minimal Competence Core for Morphosyntax and the Index of Productive Syntax.

    PubMed

    Stockman, Ida J; Newkirk-Turner, Brandi L; Swartzlander, Elaina; Morris, Lekeitha R

    2016-02-01

    This study is a response to the need for evidence-based measures of spontaneous oral language to assess African American children under the age of 4 years. We determined if pass/fail status on a minimal competence core for morphosyntax (MCC-MS) was more highly related to scores on the Index of Productive Syntax (IPSyn)-the measure of convergent criterion validity-than to scores on 3 measures of divergent validity: number of different words (Watkins, Kelly, Harbers, & Hollis, 1995), Percentage of Consonants Correct-Revised (Shriberg, Austin, Lewis, McSweeney, & Wilson, 1997), and the Leiter International Performance Scale-Revised (Roid & Miller, 1997). Archival language samples for 68 African American 3-year-olds were analyzed to determine MCC-MS pass/fail status and the scores on measures of convergent and divergent validity. Higher IPSyn scores were observed for 60 children who passed the MCC-MS than for 8 children who did not. A significant positive correlation, rpb = .73, between MCC-MS pass/fail status and IPSyn scores was observed. This coefficient was higher than MCC-MS correlations with measures of divergent validity: rpb = .13 (Leiter International Performance Scale-Revised), rpb = .42 (number of different words in 100 utterances), and rpb = .46 (Percentage of Consonants Correct-Revised). The MCC-MS has convergent criterion validity with the IPSyn. Although more research is warranted, both measures can be potentially used in oral language assessments of African American 3-year-olds.

  8. The Geoscience Spaceborne Imaging Spectroscopy Technical Committees Calibration and Validation Workshop

    NASA Technical Reports Server (NTRS)

    Ong, Cindy; Mueller, Andreas; Thome, Kurtis; Pierce, Leland E.; Malthus, Timothy

    2016-01-01

    Calibration is the process of quantitatively defining a system's responses to known, controlled signal inputs, and validation is the process of assessing, by independent means, the quality of the data products derived from those system outputs [1]. Similar to other Earth observation (EO) sensors, the calibration and validation of spaceborne imaging spectroscopy sensors is a fundamental underpinning activity. Calibration and validation determine the quality and integrity of the data provided by spaceborne imaging spectroscopy sensors and have enormous downstream impacts on the accuracy and reliability of products generated from these sensors. At least five imaging spectroscopy satellites are planned to be launched within the next five years, with the two most advanced scheduled to be launched in the next two years [2]. The launch of these sensors requires the establishment of suitable, standardized, and harmonized calibration and validation strategies to ensure that high-quality data are acquired and comparable between these sensor systems. Such activities are extremely important for the community of imaging spectroscopy users. Recognizing the need to focus on this underpinning topic, the Geoscience Spaceborne Imaging Spectroscopy (previously, the International Spaceborne Imaging Spectroscopy) Technical Committee launched a calibration and validation initiative at the 2013 International Geoscience and Remote Sensing Symposium (IGARSS) in Melbourne, Australia, and a post-conference activity of a vicarious calibration field trip at Lake Lefroy in Western Australia.

  9. Validation of the Mayo Hip Score: construct validity, reliability and responsiveness to change.

    PubMed

    Singh, Jasvinder A; Schleck, Cathy; Harmsen, W Scott; Lewallen, David G

    2016-01-19

    Previous studies have provided the initial evidence for construct validity and test-retest reliability of the Mayo Hip Score. Instruments used for Total Hip Arthroplasty (THA) outcomes assessment should be valid, reliable and responsive to change. Our main objective was to examine the responsiveness to change, association with subsequent revision and the construct validity of the Mayo hip score. Discriminant ability was assessed by calculating effect size (ES), standardized response mean (SRM) and Guyatt's responsiveness index (GRI). Minimal clinically important difference (MCII) and moderate improvement thresholds were calculated. We assessed construct validity by examining association of scores with preoperative patient characteristics and correlation with Harris hip score, and assessed association of scores with the risk of subsequent revision. Five thousand three hundred seven provided baseline data; of those with baseline data, 2,278 and 2,089 (39%) provided 2- and 5-year data, respectively. Large ES, SRM and GRI ranging 2.66-2.78, 2.42-2.61 and 1.67-1.88 were noted for Mayo hip scores with THA, respectively. The MCII and moderate improvement thresholds were 22.4-22.7 and 39.4-40.5 respectively. Hazard ratios of revision surgery were higher with lower final score or less improvement in Mayo hip score at 2-years and borderline significant/non-significant at 5-years, respectively: (1) score ≤55 with hazard ratios of 2.24 (95% CI, 1.45, 3.46; p = 0.0003) and 1.70 (95% CI, 1.00, 2.92; p = 0.05) of implant revision subsequently, compared to 72-80 points; (2) no improvement or worsening score with hazard ratios 3.94 (95% CI, 1.50, 10.30; p = 0.005) and 2.72 (95% CI, 0.85,8.70; p = 0.09), compared to improvement >50-points. Mayo hip score had significant positive correlation with younger age, male gender, lower BMI, lower ASA class and lower Deyo-Charlson index (p ≤ 0.003 for each) and with Harris hip scores (p < 0.001). Mayo Hip Score is valid, sensitive to change and associated with future risk of revision surgery in patients with primary THA.

  10. Revising the Belgian Nursing Minimum Dataset: from concept to implementation.

    PubMed

    Sermeus, Walter; van den Heede, Koen; Michiels, Dominik; Delesie, Lucas; Thonon, Olivier; Van Boven, Caroline; Codognotto, Jean; Gillet, Pierre

    2005-12-01

    The process of revising the Belgian Nursing Minimum Dataset (B-NMDS) started in 2000 and entailed four major phases. The first phase (June-October 2002) involved the development of a conceptual framework based on a literature review and secondary data analysis. The Nursing Interventions Classification (NIC) was selected as a framework for the revision of the original B-NMDS. The second phase (November 2002-September 2003) focused on language development for six care programs evaluated by panels of clinical experts (N=75). These panels identified the following items as priorities for the revised B-NMDS: hospital financing, nurse staffing allocation, assessment of the appropriateness of hospitalisation, and quality management. During this period, we developed a draft instrument with 92 variables using the NIC. This led to an alpha version of a revised B-NMDS. The third phase (October 2003-December 2004) focused on data collection and validation of the new tool. The revised B-NMDS (alpha version) was tested in 158 nursing wards in 66 Belgian hospitals from December 2003 until March 2004. This test generated data for some 95,000 in-patient days. The interrater reliability of the revised B-NMDS was assessed. The criterion-related validity of the revised B-NMDS was compared to that of the original B-NMDS. The discriminative power of the revised B-NMDS was also assessed to select the most relevant variables for data collection. This resulted in a beta version of the revised B-NMDS in December 2004. The records of the revised B-NMDS were linked to the Hospital Discharge Dataset and other mandatory datasets to integrate the revised B-NMDS into the overall healthcare management system. The fourth phase (January 2005-December 2005) is presently focusing on information management. Nationwide implementation is foreseen by January 2007.

  11. The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R): A Scale to Assist the Diagnosis of Autism Spectrum Disorder in Adults--An International Validation Study

    ERIC Educational Resources Information Center

    Ritvo, Riva Ariella; Ritvo, Edward R.; Guthrie, Donald; Ritvo, Max J.; Hufnagel, Demetra H.; McMahon, William; Tonge, Bruce; Mataix-Cols, David; Jassi, Amita; Attwood, Tony; Eloff, Johann

    2011-01-01

    The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R) is a valid and reliable instrument to assist the diagnosis of adults with Autism Spectrum Disorders (ASD). The 80-question scale was administered to 779 subjects (201 ASD and 578 comparisons). All ASD subjects met inclusion criteria: DSM-IV-TR, ADI/ADOS diagnoses and standardized IQ…

  12. Peabody Picture Vocabulary Test-Revised (PPVT-R).

    ERIC Educational Resources Information Center

    Vance, H. Robert; Stone, J. E.

    1990-01-01

    The Peabody Picture Vocabulary Test-Revised assesses standard American English receptive vocabulary in individuals, both handicapped and nonhandicapped, ages 2 to 40. This paper describes the test's administration, summation of data, standardization, reliability, and validity. (JDD)

  13. Validity of administrative database code algorithms to identify vascular access placement, surgical revisions, and secondary patency.

    PubMed

    Al-Jaishi, Ahmed A; Moist, Louise M; Oliver, Matthew J; Nash, Danielle M; Fleet, Jamie L; Garg, Amit X; Lok, Charmaine E

    2018-03-01

    We assessed the validity of physician billing codes and hospital admission using International Classification of Diseases 10th revision codes to identify vascular access placement, secondary patency, and surgical revisions in administrative data. We included adults (≥18 years) with a vascular access placed between 1 April 2004 and 31 March 2013 at the University Health Network, Toronto. Our reference standard was a prospective vascular access database (VASPRO) that contains information on vascular access type and dates of placement, dates for failure, and any revisions. We used VASPRO to assess the validity of different administrative coding algorithms by calculating the sensitivity, specificity, and positive predictive values of vascular access events. The sensitivity (95% confidence interval) of the best performing algorithm to identify arteriovenous access placement was 86% (83%, 89%) and specificity was 92% (89%, 93%). The corresponding numbers to identify catheter insertion were 84% (82%, 86%) and 84% (80%, 87%), respectively. The sensitivity of the best performing coding algorithm to identify arteriovenous access surgical revisions was 81% (67%, 90%) and specificity was 89% (87%, 90%). The algorithm capturing arteriovenous access placement and catheter insertion had a positive predictive value greater than 90% and arteriovenous access surgical revisions had a positive predictive value of 20%. The duration of arteriovenous access secondary patency was on average 578 (553, 603) days in VASPRO and 555 (530, 580) days in administrative databases. Administrative data algorithms have fair to good operating characteristics to identify vascular access placement and arteriovenous access secondary patency. Low positive predictive values for surgical revisions algorithm suggest that administrative data should only be used to rule out the occurrence of an event.

  14. Validation of the tool assessment of clinical education (AssCE): A study using Delphi method and clinical experts.

    PubMed

    Löfmark, Anna; Mårtensson, Gunilla

    2017-03-01

    The aim of the present study was to establish the validity of the tool Assessment of Clinical Education (AssCE). The tool is widely used in Sweden and some Nordic countries for assessing nursing students' performance in clinical education. It is important that the tools in use be subjected to regular audit and critical reviews. The validation process, performed in two stages, was concluded with a high level of congruence. In the first stage, Delphi technique was used to elaborate the AssCE tool using a group of 35 clinical nurse lecturers. After three rounds, we reached consensus. In the second stage, a group of 46 clinical nurse lecturers representing 12 universities in Sweden and Norway audited the revised version of the AssCE in relation to learning outcomes from the last clinical course at their respective institutions. Validation of the revised AssCE was established with high congruence between the factors in the AssCE and examined learning outcomes. The revised AssCE tool seems to meet its objective to be a validated assessment tool for use in clinical nursing education. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. LED-based near infrared sensor for cancer diagnostics

    NASA Astrophysics Data System (ADS)

    Bogomolov, Andrey; Ageev, Vladimir; Zabarylo, Urszula; Usenov, Iskander; Schulte, Franziska; Kirsanov, Dmitry; Belikova, Valeria; Minet, Olaf; Feliksberger, E.; Meshkovsky, I.; Artyushenko, Viacheslav

    2016-03-01

    Optical spectroscopic technologies are increasingly used for cancer diagnostics. Feasibility of differentiation between malignant and healthy samples of human kidney using Fluorescence, Raman, MIR and NIR spectroscopy has been recently reported . In the present work, a simplification of NIR spectroscopy method has been studied. Traditional high-resolution NIR spectrometry was replaced by an optical sensor based on a set of light-emitting diodes at selected wavelengths as light sources and a photodiode. Two prototypes of the sensor have been developed and tested using 14 in-vitro samples of seven kidney tumor patients. Statistical evaluation of results using principal component analysis and partial least-squares discriminant analysis has been performed. Despite only partial discrimination between tumor and healthy tissue achieved by the presented new technique, the results evidence benefits of LED-based near-infrared sensing used for oncological diagnostics. Publisher's Note: This paper, originally published on 4 March, 2016, was replaced with a corrected/revised version on 7 April, 2016. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance.

  16. Revision and validation of a scale to assess pregnancy stress.

    PubMed

    Chen, Chung-Hey

    2015-03-01

    Pregnancy is a potentially stressful event. Prenatal stress alters maternal endocrine and immune systems, has been implicated in the etiology of prenatal complications or postnatal psychiatric disorders, and may adversely affect fetal health. The 30-item Pregnancy Stress Rating Scale (PSRS), initially developed in 1983 by Chen and colleagues, is the only measure to date designed specifically to evaluate prenatal stress. The purpose of this study was to reconsider and revise the 30-item PSRS and validate the new PSRS. A cross-sectional design was used. Adding new items of pregnancy stress generated from clinical experience and expert recommendations resulted in a 40-item revised PSRS that was more reflective of current social conditions. Three hundred pregnant women, recruited from the antenatal clinic of a medical center in southern Taiwan, completed the revised PSRS to assess its internal consistency, test-retest reliability, construct validity, and convergent and discriminate validity. The final 36-item PSRS (PSRS36) was derived by deleting four items with relatively low item-total correlation coefficients or factor loadings. The resultant 36-item scale showed good internal consistency (α = .92) and 2-week test-retest reliability (r = .82). Factor analysis confirmed construct validity and suggested five prenatal stress dimensions, which explained 52.17% of the total variance. Convergent and discriminate validities were indicated by significant correlations among the PSRS36, Perceived Stress Scale, and Interpersonal Support Evaluation List. The PSRS36 is a psychometrically sound and practical tool for nurses and other healthcare providers to assess prenatal stress and to examine intervention protocols in Taiwanese prenatal women. More research is recommended to determine whether the PSRS36 may be used in other racial-ethnic groups.

  17. Validating the Revised Illness Perception Questionnaire as a Measure of Parent Perceptions of Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Mire, Sarah S.; Tolar, Tammy D.; Brewton, Christie M.; Raff, Natalie S.; McKee, Shannon L.

    2018-01-01

    The illness perception questionnaire (IPQ) and its revision (IPQ-R) measure perceptions about health-related diagnoses and the influence of cognitions on coping. In this study, the factor structure of a version revised for use with autism spectrum disorder (ASD) was investigated with a sample of parents (n = 361) whose children have ASD.…

  18. Continuous coaxial cable sensors for monitoring of RC structures with electrical time domain reflectometry

    NASA Astrophysics Data System (ADS)

    Chen, Genda; Mu, Huimin; Pommerenke, David; Drewniak, James L.

    2003-08-01

    This study was aimed at developing and validating a new type of coaxial cable sensors that can be used to detect cracks or measure strains in reinforced concrete (RC) structures. The new sensors were designed based on the change in outer conductor configuration under strain effects in contrast to the geometry-based design in conventional coaxial cable sensors. Both numerical simulations and calibration tests with strain gauges of a specific design of the proposed cables were conducted to study the cables' sensitivity. Four designs of the proposed type of sensors were then respectively mounted near the surface of six 3-foot-long RC beams. They were tested in bending to further validate the cables' sensitivity in concrete members. The calibration test results generally agree with the numerical simulations. They showed that the proposed sensors are over 10~50 times more sensitive than conventional cable sensors. The test results of the beams not only validate the sensitivity of the new sensors but also indicate a good correlation with the measured crack width.

  19. Taxonomic revision of the South American catfish genus Ageneiosus (Siluriformes: Auchenipteridae) with the description of four new species

    USGS Publications Warehouse

    Ribeiro, Frank R.V.; Rapp Py-Daniel, Lúcia H.; Walsh, Stephen J.

    2017-01-01

    The catfish genus Ageneiosus in the exclusively Neotropical family Auchenipteridae is revised. Species of Ageneiosus are widely distributed in all major South American continental drainages except the São Francisco River basin and small rivers along the Brazilian east coast. The taxonomic revision was based on examination of available type specimens, additional museum material and comparisons of original descriptions. A suite of morphometric, meristic and qualitative characters of internal and external anatomy were used to diagnose valid species and determine synonyms. Thirteen valid species are recognized in the genus Ageneiosus, some of which are widely distributed across South America. Ageneiosus pardalis is the only trans-Andean species in the genus. Ageneiosus polystictus and Ageneiosus uranophthalmus are more widely distributed than previously reported. Ageneiosus marmoratus is a junior synonym of Ageneiosus inermis. Ageneiosus dentatus is a valid species and its name is removed from the synonymy of Ageneiosus ucayalensis. Four new species are described: Ageneiosus akamai, Ageneiosus apiaka, Ageneiosus intrusus and Ageneiosus lineatus, all from the Amazon River basin. A dichotomous key for all 13 valid species of Ageneiosus species is provided.

  20. Validation of General Electric Aviation DAPS2015 Digital Recording and 1/3 Octave Analysis System for Use in Support of Aircraft Noise Certification Efforts in Compliance with 14 CFR Part 36; Letter Report: V324-FA5JBQ-LR4 Rev. 1

    DOT National Transportation Integrated Search

    2017-10-31

    NOTE: This is a revision of Letter Report V324-FA5JBQ-LR4. The purpose of the revision is to correctly identify the system designation for which the validation applies. The applicant originally identified the materials provided in support of this val...

  1. The Validity of Scores from the "GRE"® revised General Test for Forecasting Performance in Business Schools: Phase One. ETS GRE® Board Research Report. ETS GRE®-14-01. ETS Research Report. RR-14-17

    ERIC Educational Resources Information Center

    Young, John W.; Klieger, David; Bochenek, Jennifer; Li, Chen; Cline, Fred

    2014-01-01

    Scores from the "GRE"® revised General Test provide important information regarding the verbal and quantitative reasoning abilities and analytical writing skills of applicants to graduate programs. The validity and utility of these scores depend upon the degree to which the scores predict success in graduate and business school in…

  2. Validation of the iHealth BP5 wireless upper arm blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Shang, Fujun; Zhu, Yizheng; Zhu, Zhenlai; Liu, Lei; Wan, Yi

    2013-10-01

    The aim of this study was to validate the iHealth BP5 wireless upper arm blood pressure (BP) monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for validation of BP measuring devices in adults was followed precisely. A total of 99 pairs of test device and reference BP measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 71, 89, and 97 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 73, 90, and 99 mmHg for diastolic blood pressure (DBP), respectively. The mean ± SD device-observer difference was -1.21 ± 5.87 mmHg for SBP and -1.04 ± 5.28 mmHg for DBP. The number of participants with two or three device-observer differences within 5 mmHg was 25 for SBP and 28 for DBP. In addition, three participants had no device-observer difference within 5 mmHg for SBP and none of the participants had the same for DBP. According to the validation results on the basis of the ESH-IP revision 2010, the iHealth BP5 wireless upper arm BP monitor can be recommended for self/home measurement in an adult population.

  3. Embedded performance validity tests within the Hopkins Verbal Learning Test - Revised and the Brief Visuospatial Memory Test - Revised.

    PubMed

    Sawyer, R John; Testa, S Marc; Dux, Moira

    2017-01-01

    Various research studies and neuropsychology practice organizations have reiterated the importance of developing embedded performance validity tests (PVTs) to detect potentially invalid neurocognitive test data. This study investigated whether measures within the Hopkins Verbal Learning Test - Revised (HVLT-R) and the Brief Visuospatial Memory Test - Revised (BVMT-R) could accurately classify individuals who fail two or more PVTs during routine clinical assessment. The present sample of 109 United States military veterans (Mean age = 52.4, SD = 13.3), all consisted of clinically referred patients and received a battery of neuropsychological tests. Based on performance validity findings, veterans were assigned to valid (n = 86) or invalid (n = 23) groups. Of the 109 patients in the overall sample, 77 were administered the HLVT-R and 75 were administered the BVMT-R, which were examined for classification accuracy. The HVLT-R Recognition Discrimination Index and the BVMT-R Retention Percentage showed good to adequate discrimination with an area under the curve of .78 and .70, respectively. The HVLT-R Recognition Discrimination Index showed sensitivity of .53 with specificity of .93. The BVMT-R Retention Percentage demonstrated sensitivity of .31 with specificity of .92. When used in conjunction with other PVTs, these new embedded PVTs may be effective in the detection of invalid test data, although they are not intended for use in patients with dementia.

  4. SeaWiFS technical report series. Volume 5: Ocean optics protocols for SeaWiFS validation

    NASA Technical Reports Server (NTRS)

    Mueller, James L.; Austin, Roswell W.; Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor)

    1992-01-01

    Protocols are presented for measuring optical properties, and other environmental variables, to validate the radiometric performance of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), and to develop and validate bio-optical algorithms for use with SeaWiFS data. The protocols are intended to establish foundations for a measurement strategy to verify the challenging SeaWiFS accuracy goals of 5 percent in water-leaving radiances and 35 percent in chlorophyll alpha concentration. The protocols first specify the variables which must be measured, and briefly review rationale. Subsequent chapters cover detailed protocols for instrument performance specifications, characterizing and calibration instruments, methods of making measurements in the field, and methods of data analysis. These protocols were developed at a workshop sponsored by the SeaWiFS Project Office (SPO) and held at the Naval Postgraduate School in Monterey, California (9-12 April, 1991). This report is the proceedings of that workshop, as interpreted and expanded by the authors and reviewed by workshop participants and other members of the bio-optical research community. The protocols are a first prescription to approach unprecedented measurement accuracies implied by the SeaWiFS goals, and research and development are needed to improve the state-of-the-art in specific areas. The protocols should be periodically revised to reflect technical advances during the SeaWiFS Project cycle.

  5. Korean version of the Revised Caregiving Appraisal Scale: a translation and validation study.

    PubMed

    Lee, JuHee; Friedmann, Erika; Picot, Sandra J; Thomas, Sue Ann; Kim, Cho Ja

    2007-08-01

    This paper is a report of a study to examine the reliability and validity of a Korean version of the Revised Caregiving Appraisal Scale with Korean caregivers of older stroke survivors. The Revised Caregiving Appraisal Scale was developed in the United States of America for an American English-speaking population to measure primary caregivers' appraisals of potential stressors and the efficacy of their coping efforts related to caregiving experiences. Using the back-translation method, the instrument was translated into Korean. The Korean version of the Revised Caregiving Appraisal Scale was self-administered by 147 primary family caregivers recruited from three outpatient clinics and two home health agencies in Korea. The study was conducted in 2005. In this sample, Cronbach's alpha for the total scale was 0.86. Reliability coefficients for each of the five subscales ranged from 0.40 to 0.85. Two subscales, burden and satisfaction, showed good reliability; one subscale, impact, showed marginally acceptable reliability; two subscales, mastery and demand, had low reliability. Principal components factor analysis of the Korean version of the Revised Caregiving Appraisal Scale yielded six factors. Except for the mastery domain, which was divided into two factors, the other factors were similar to those in the original scale. The Korean version of the Revised Caregiving Appraisal Scale had adequate reliability and validity in a sample of Korean caregivers of stroke survivors. It can be used to assess the impact of caregiving and interventions on Korean caregiver attitudes. Further studies are needed with different categories of caregiver.

  6. Generalized worry disorder: a review of DSM-IV generalized anxiety disorder and options for DSM-V.

    PubMed

    Andrews, Gavin; Hobbs, Megan J; Borkovec, Thomas D; Beesdo, Katja; Craske, Michelle G; Heimberg, Richard G; Rapee, Ronald M; Ruscio, Ayelet Meron; Stanley, Melinda A

    2010-02-01

    Generalized anxiety disorder (GAD) has undergone a series of substantial classificatory changes since its first inclusion in DSM-III. The majority of these revisions have been in response to its poor inter-rater reliability and concerns that it may lack diagnostic validity. This article provides options for the revision of the DSM-IV GAD criteria for DSM-V. First, searches were conducted to identify the evidence that previous DSM Work Groups relied upon when revising the DSM-III-R GAD and the overanxious disorder classifications. Second, the literature pertaining to the DSM-IV criteria for GAD was examined. The review presents a number of options to be considered for DSM-V. One option is for GAD to be re-labeled in DSM-V as generalized worry disorder. This would reflect its hallmark feature. Proposed revisions would result in a disorder that is characterized by excessive anxiety and worry generalized to a number of events or activities for 3 months or more. Worry acts as a cognitive coping strategy that manifests in avoidant behaviors. The reliability and validity of the proposed changes could be investigated in DSM-V validity tests and field trials.

  7. Using Neural Networks for Sensor Validation

    NASA Technical Reports Server (NTRS)

    Mattern, Duane L.; Jaw, Link C.; Guo, Ten-Huei; Graham, Ronald; McCoy, William

    1998-01-01

    This paper presents the results of applying two different types of neural networks in two different approaches to the sensor validation problem. The first approach uses a functional approximation neural network as part of a nonlinear observer in a model-based approach to analytical redundancy. The second approach uses an auto-associative neural network to perform nonlinear principal component analysis on a set of redundant sensors to provide an estimate for a single failed sensor. The approaches are demonstrated using a nonlinear simulation of a turbofan engine. The fault detection and sensor estimation results are presented and the training of the auto-associative neural network to provide sensor estimates is discussed.

  8. A review of the revised Functional Capacity Index as a predictor of 12 month outcomes following injury.

    PubMed

    Palmer, Cameron S; Cameron, Peter A; Gabbe, Belinda J

    2017-03-01

    The measurement of functional outcomes following severe trauma has been widely recognised as a priority for countries with developed trauma systems. In this respect, the Functional Capacity Index (FCI), a multi-attribute index which has been incorporated into the most recent Abbreviated Injury Scale (AIS) dictionary, is potentially attractive as it offers 12-month functional outcome predictions for patients captured by existing AIS-coded datasets. This review paper outlines the development, construction and validation of the predictive form of the FCI (termed the pFCI), the modifications made which produced the currently available 'revised' pFCI, and the extent to which the revised pFCI has been validated and used. The original pFCI performed poorly in validation studies. The revised pFCI does not address many of the identified limitations of the original version, and despite the ready availability of a truncated version in the AIS dictionary, it has only been used in a handful of studies since its introduction several years ago. Additionally, there is little evidence for its validity. It is suggested that the pFCI should be better validated, whether in the narrow population group of young, healthy individuals for which it was developed, or in the wider population of severely injured patients. Methods for accounting for the presence of multiple injures (of which two have currently been used) should also be evaluated. Many factors other than anatomical injury are known to affect functional outcomes following trauma. However, it is intuitive that any model which attempts to predict the ongoing morbidity burden in a trauma population should consider the effects of the injuries sustained. Although the revised pFCI potentially offers a low-cost assessment of likely functional limitations resulting from anatomical injury, it must be more rigorously evaluated before more comprehensive predictive tools can be developed from it. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Infrared Spectral Radiance Intercomparisons With Satellite and Aircraft Sensors

    NASA Technical Reports Server (NTRS)

    Larar, Allen M.; Zhou, Daniel K.; Liu, Xu; Smith, William L.

    2014-01-01

    Measurement system validation is critical for advanced satellite sounders to reach their full potential of improving observations of the Earth's atmosphere, clouds, and surface for enabling enhancements in weather prediction, climate monitoring capability, and environmental change detection. Experimental field campaigns, focusing on satellite under-flights with well-calibrated FTS sensors aboard high-altitude aircraft, are an essential part of the validation task. Airborne FTS systems can enable an independent, SI-traceable measurement system validation by directly measuring the same level-1 parameters spatially and temporally coincident with the satellite sensor of interest. Continuation of aircraft under-flights for multiple satellites during multiple field campaigns enables long-term monitoring of system performance and inter-satellite cross-validation. The NASA / NPOESS Airborne Sounder Testbed - Interferometer (NAST-I) has been a significant contributor in this area by providing coincident high spectral/spatial resolution observations of infrared spectral radiances along with independently-retrieved geophysical products for comparison with like products from satellite sensors being validated. This presentation gives an overview of benefits achieved using airborne sensors such as NAST-I utilizing examples from recent field campaigns. The methodology implemented is not only beneficial to new sensors such as the Cross-track Infrared Sounder (CrIS) flying aboard the Suomi NPP and future JPSS satellites but also of significant benefit to sensors of longer flight heritage such as the Atmospheric InfraRed Sounder (AIRS) and the Infrared Atmospheric Sounding Interferometer (IASI) on the AQUA and METOP-A platforms, respectively, to ensure data quality continuity important for climate and other applications. Infrared spectral radiance inter-comparisons are discussed with a particular focus on usage of NAST-I data for enabling inter-platform cross-validation.

  10. WHO Expert Committee on Specifications for Pharmaceutical Preparations. Forty-ninth report.

    PubMed

    2015-01-01

    The Expert Committee on Specifications for Pharmaceutical Preparations works towards clear, independent and practical standards and guidelines for the quality assurance of medicines. Standards are developed by the Committee through worldwide consultation and an international consensus-building process. The following new guidelines were adopted and recommended for use. Revised procedure for the development of monographs and other texts for The International Pharmacopoeia; Revised updating mechanism for the section on radiopharmaceuticals in The International Pharmacopoeia; Revision of the supplementary guidelines on good manufacturing practices: validation, Appendix 7: non-sterile process validation; General guidance for inspectors on hold-time studies; 16 technical supplements to Model guidance for the storage and transport of time- and temperature-sensitive pharmaceutical products; Recommendations for quality requirements when plant-derived artemisinin is used as a starting material in the production of antimalarial active pharmaceutical ingredients; Multisource (generic) pharmaceutical products: guidelines on registration requirements to establish interchangeability: revision; Guidance on the selection of comparator pharmaceutical products for equivalence assessment of interchangeable multisource (generic) products: revision; and Good review practices: guidelines for national and regional regulatory authorities.

  11. Variables influencing wearable sensor outcome estimates in individuals with stroke and incomplete spinal cord injury: a pilot investigation validating two research grade sensors.

    PubMed

    Jayaraman, Chandrasekaran; Mummidisetty, Chaithanya Krishna; Mannix-Slobig, Alannah; McGee Koch, Lori; Jayaraman, Arun

    2018-03-13

    Monitoring physical activity and leveraging wearable sensor technologies to facilitate active living in individuals with neurological impairment has been shown to yield benefits in terms of health and quality of living. In this context, accurate measurement of physical activity estimates from these sensors are vital. However, wearable sensor manufacturers generally only provide standard proprietary algorithms based off of healthy individuals to estimate physical activity metrics which may lead to inaccurate estimates in population with neurological impairment like stroke and incomplete spinal cord injury (iSCI). The main objective of this cross-sectional investigation was to evaluate the validity of physical activity estimates provided by standard proprietary algorithms for individuals with stroke and iSCI. Two research grade wearable sensors used in clinical settings were chosen and the outcome metrics estimated using standard proprietary algorithms were validated against designated golden standard measures (Cosmed K4B2 for energy expenditure and metabolic equivalent and manual tallying for step counts). The influence of sensor location, sensor type and activity characteristics were also studied. 28 participants (Healthy (n = 10); incomplete SCI (n = 8); stroke (n = 10)) performed a spectrum of activities in a laboratory setting using two wearable sensors (ActiGraph and Metria-IH1) at different body locations. Manufacturer provided standard proprietary algorithms estimated the step count, energy expenditure (EE) and metabolic equivalent (MET). These estimates were compared with the estimates from gold standard measures. For verifying validity, a series of Kruskal Wallis ANOVA tests (Games-Howell multiple comparison for post-hoc analyses) were conducted to compare the mean rank and absolute agreement of outcome metrics estimated by each of the devices in comparison with the designated gold standard measurements. The sensor type, sensor location, activity characteristics and the population specific condition influences the validity of estimation of physical activity metrics using standard proprietary algorithms. Implementing population specific customized algorithms accounting for the influences of sensor location, type and activity characteristics for estimating physical activity metrics in individuals with stroke and iSCI could be beneficial.

  12. The Childhood Cancer Survivor Study-Neurocognitive Questionnaire (CCSS-NCQ) Revised: Item Response Analysis and Concurrent Validity

    PubMed Central

    Kenzik, Kelly M.; Huang, I-Chan; Brinkman, Tara M.; Baughman, Brandon; Ness, Kirsten K.; Shenkman, Elizabeth A.; Hudson, Melissa M.; Robison, Leslie L.; Krull, Kevin R.

    2014-01-01

    Objective Childhood cancer survivors are at risk for neurocognitive impairment related to cancer diagnosis or treatment. This study refined and further validated the Childhood Cancer Survivor Study Neurocognitive Questionnaire (CCSS-NCQ), a scale developed to screen for impairment in long-term survivors of childhood cancer. Method Items related to task efficiency, memory, organization and emotional regulation domains were examined using item response theory (IRT). Data were collected from 833 adult survivors of childhood cancer in the St. Jude Lifetime Cohort Study who completed self-report and direct neurocognitive testing. The revision process included: 1) content validity mapping of items to domains, 2) constructing a revised CCSS-NCQ, 3) selecting items within specific domains using IRT, and 4) evaluating concordance between the revised CCSS-NCQ and direct neurocognitive assessment. Results Using content and measurement properties, 32 items were retained (8 items in 4 domains). Items captured low to middle levels of neurocognitive concerns. The latent domain scores demonstrated poor convergent/divergent validity with the direct assessments. Adjusted effect sizes (Cohen's d) for agreement between self-reported memory and direct memory assessment were moderate for total recall (ES=0.66), long-term memory (ES=0.63), and short-term memory (ES=0.55). Effect sizes between self-rated task efficiency and direct assessment of attention were moderate for focused attention (ES=0.70) and attention span (ES=0.50), but small for sustained attention (ES=0.36). Cranial radiation therapy and female gender were associated with lower self-reported neurocognitive function. Conclusion The revised CCSS-NCQ demonstrates adequate measurement properties for assessing day-to-day neurocognitive concerns in childhood cancer survivors, and adds useful information to direct assessment. PMID:24933482

  13. Impact of applying the more stringent validation criteria of the revised European Society of Hypertension International Protocol 2010 on earlier validation studies.

    PubMed

    Stergiou, George S; Karpettas, Nikos; Atkins, Neil; O'Brien, Eoin

    2011-04-01

    Since 2002 when the European Society of Hypertension International Protocol (ESH-IP) was published it has become the preferred protocol for validating blood pressure monitors worldwide. In 2010, a revised version of the ESH-IP with more stringent criteria was published. This study assesses the impact of applying the revised ESH-IP criteria. A systematic literature review of ESH-IP studies reported between 2002 and 2010 was conducted. The impact of applying the ESH-IP 2010 criteria retrospectively on the data reported in these studies was investigated. The performance of the oscillometric devices in the last decade was also investigated on the basis of the ESH-IP criteria. Among 119 published studies, 112 with sufficient data were analyzed. According to ESH-IP 2002, the test device failed in 19 studies, whereas by applying the ESH-IP 2010 criteria in 28 additional studies increased the failure rate from 17 to 42%. Of these 28 studies, in 20 (71%) the test device failed at part 1 (accuracy per measurement) and in 22 (79%) at part 2 (accuracy per subject). Most of the failures involved the '5 mmHg or less' criterion. In the last decade there has been a consistent trend toward improved performance of oscillometric devices assessed on the basis of the ESH-IP criteria. This retrospective analysis shows that the stricter revised ESH-IP 2010 criteria will noticeably increase the failure rate of devices being validated. Oscillometric devices are becoming more accurate, and the revised ESH-IP by acknowledging this trend will allow more accurate devices to enter the market.

  14. Neural Network-Based Sensor Validation for Turboshaft Engines

    NASA Technical Reports Server (NTRS)

    Moller, James C.; Litt, Jonathan S.; Guo, Ten-Huei

    1998-01-01

    Sensor failure detection, isolation, and accommodation using a neural network approach is described. An auto-associative neural network is configured to perform dimensionality reduction on the sensor measurement vector and provide estimated sensor values. The sensor validation scheme is applied in a simulation of the T700 turboshaft engine in closed loop operation. Performance is evaluated based on the ability to detect faults correctly and maintain stable and responsive engine operation. The set of sensor outputs used for engine control forms the network input vector. Analytical redundancy is verified by training networks of successively smaller bottleneck layer sizes. Training data generation and strategy are discussed. The engine maintained stable behavior in the presence of sensor hard failures. With proper selection of fault determination thresholds, stability was maintained in the presence of sensor soft failures.

  15. GNC Architecture Design for ARES Simulation. Revision 3.0. Revision 3.0

    NASA Technical Reports Server (NTRS)

    Gay, Robert

    2006-01-01

    The purpose of this document is to describe the GNC architecture and associated interfaces for all ARES simulations. Establishing a common architecture facilitates development across the ARES simulations and provides an efficient mechanism for creating an end-to-end simulation capability. In general, the GNC architecture is the frame work in which all GNC development takes place, including sensor and effector models. All GNC software applications have a standard location within the architecture making integration easier and, thus more efficient.

  16. Confirmatory Factor Analysis of a Family Quality of Life Scale for Taiwanese Families of Children With Intellectual Disability/Developmental Delay.

    PubMed

    Chiu, Chun-Yu; Seo, Hyojeong; Turnbull, Ann P; Summers, Jean Ann

    2017-04-01

    The Beach Center Family Quality of Life Scale is an internationally validated instrument for measuring family outcomes. To revise the scale for better alignment with the Family Quality of Life theory, the authors excluded non-outcome items in this revision. In this study, we examined reliability and validity of the revised scale (i.e., the FQoL Scale-21) and its scores for Taiwanese families of children and youth with intellectual disability and developmental delay (age 0-18). Results from 400 Taiwanese respondents suggested that the FQoL Scale-21 has the potential to be used as an indicator of positive outcomes in intervention evaluation, policy making, and service delivery.

  17. Test, revision, and cross-validation of the Physical Activity Self-Definition Model.

    PubMed

    Kendzierski, Deborah; Morganstein, Mara S

    2009-08-01

    Structural equation modeling was used to test an extended version of the Kendzierski, Furr, and Schiavoni (1998) Physical Activity Self-Definition Model. A revised model using data from 622 runners fit the data well. Cross-validation indices supported the revised model, and this model also provided a good fit to data from 397 cyclists. Partial invariance was found across activities. In both samples, perceived commitment and perceived ability had direct effects on self-definition, and perceived wanting, perceived trying, and enjoyment had indirect effects. The contribution of perceived ability to self-definition did not differ across activities. Implications concerning the original model, indirect effects, skill salience, and the role of context in self-definition are discussed.

  18. Efficient placement of structural dynamics sensors on the space station

    NASA Technical Reports Server (NTRS)

    Lepanto, Janet A.; Shepard, G. Dudley

    1987-01-01

    System identification of the space station dynamic model will require flight data from a finite number of judiciously placed sensors on it. The placement of structural dynamics sensors on the space station is a particularly challenging problem because the station will not be deployed in a single mission. Given that the build-up sequence and the final configuration for the space station are currently undetermined, a procedure for sensor placement was developed using the assembly flights 1 to 7 of the rephased dual keel space station as an example. The procedure presented approaches the problem of placing the sensors from an engineering, as opposed to a mathematical, point of view. In addition to locating a finite number of sensors, the procedure addresses the issues of unobserved structural modes, dominant structural modes, and the trade-offs involved in sensor placement for space station. This procedure for sensor placement will be applied to revised, and potentially more detailed, finite element models of the space station configuration and assembly sequence.

  19. Validity of the Cambridge Cognitive Examination-Revised new Executive Function Scores in the diagnosis of dementia: some early findings.

    PubMed

    Heinik, Jeremia; Solomesh, Isaac

    2007-03-01

    The Cambridge Cognitive Examination-Revised introduces 2 new executive items (Ideational Fluency and Visual Reasoning), which separately or combined with 2 executive items in the former version (word list generation and similarities) might constitute an Executive Function Score (EFS). The authors studied the validity of these new EFSs in 51 demented (dementia of the Alzheimer's type, vascular dementia) and nondemented individuals (depressives and normals). The new EFSs were found valid to accurately differentiate between demented and nondemented subjects; however, they were considerably less so when specific diagnoses were considered. Correlations between the variously combined executive scores and the cognitive scales and subscales studied were prevalently low to moderate, and ranged from high and significant to low and nonsignificant when the 4 executive items were correlated to each other. The ability of the executive scores to discriminate demented from nondemented individuals was lower compared with the Cambridge Cognitive Examination-Revised scores. EFS was found internally consistent.

  20. Sensor data validation and reconstruction. Phase 1: System architecture study

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The sensor validation and data reconstruction task reviewed relevant literature and selected applicable validation and reconstruction techniques for further study; analyzed the selected techniques and emphasized those which could be used for both validation and reconstruction; analyzed Space Shuttle Main Engine (SSME) hot fire test data to determine statistical and physical relationships between various parameters; developed statistical and empirical correlations between parameters to perform validation and reconstruction tasks, using a computer aided engineering (CAE) package; and conceptually designed an expert system based knowledge fusion tool, which allows the user to relate diverse types of information when validating sensor data. The host hardware for the system is intended to be a Sun SPARCstation, but could be any RISC workstation with a UNIX operating system and a windowing/graphics system such as Motif or Dataviews. The information fusion tool is intended to be developed using the NEXPERT Object expert system shell, and the C programming language.

  1. Validating novel air pollution sensors to improve exposure estimates for epidemiological analyses and citizen science.

    PubMed

    Jerrett, Michael; Donaire-Gonzalez, David; Popoola, Olalekan; Jones, Roderic; Cohen, Ronald C; Almanza, Estela; de Nazelle, Audrey; Mead, Iq; Carrasco-Turigas, Glòria; Cole-Hunter, Tom; Triguero-Mas, Margarita; Seto, Edmund; Nieuwenhuijsen, Mark

    2017-10-01

    Low cost, personal air pollution sensors may reduce exposure measurement errors in epidemiological investigations and contribute to citizen science initiatives. Here we assess the validity of a low cost personal air pollution sensor. Study participants were drawn from two ongoing epidemiological projects in Barcelona, Spain. Participants repeatedly wore the pollution sensor - which measured carbon monoxide (CO), nitric oxide (NO), and nitrogen dioxide (NO 2 ). We also compared personal sensor measurements to those from more expensive instruments. Our personal sensors had moderate to high correlations with government monitors with averaging times of 1-h and 30-min epochs (r ~ 0.38-0.8) for NO and CO, but had low to moderate correlations with NO 2 (~0.04-0.67). Correlations between the personal sensors and more expensive research instruments were higher than with the government monitors. The sensors were able to detect high and low air pollution levels in agreement with expectations (e.g., high levels on or near busy roadways and lower levels in background residential areas and parks). Our findings suggest that the low cost, personal sensors have potential to reduce exposure measurement error in epidemiological studies and provide valid data for citizen science studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Design and Validation of a 150 MHz HFFQCM Sensor for Bio-Sensing Applications

    PubMed Central

    Fernández, Román; García, Pablo; García, María; Jiménez, Yolanda; Arnau, Antonio

    2017-01-01

    Acoustic wave resonators have become suitable devices for a broad range of sensing applications due to their sensitivity, low cost, and integration capability, which are all factors that meet the requirements for the resonators to be used as sensing elements for portable point of care (PoC) platforms. In this work, the design, characterization, and validation of a 150 MHz high fundamental frequency quartz crystal microbalance (HFF-QCM) sensor for bio-sensing applications are introduced. Finite element method (FEM) simulations of the proposed design are in good agreement with the electrical characterization of the manufactured resonators. The sensor is also validated for bio-sensing applications. For this purpose, a specific sensor cell was designed and manufactured that addresses the critical requirements associated with this type of sensor and application. Due to the small sensing area and the sensor’s fragility, these requirements include a low-volume flow chamber in the nanoliter range, and a system approach that provides the appropriate pressure control for assuring liquid confinement while maintaining the integrity of the sensor with a good base line stability and easy sensor replacement. The sensor characteristics make it suitable for consideration as the elemental part of a sensor matrix in a multichannel platform for point of care applications. PMID:28885551

  3. Model-Based Method for Sensor Validation

    NASA Technical Reports Server (NTRS)

    Vatan, Farrokh

    2012-01-01

    Fault detection, diagnosis, and prognosis are essential tasks in the operation of autonomous spacecraft, instruments, and in situ platforms. One of NASA s key mission requirements is robust state estimation. Sensing, using a wide range of sensors and sensor fusion approaches, plays a central role in robust state estimation, and there is a need to diagnose sensor failure as well as component failure. Sensor validation can be considered to be part of the larger effort of improving reliability and safety. The standard methods for solving the sensor validation problem are based on probabilistic analysis of the system, from which the method based on Bayesian networks is most popular. Therefore, these methods can only predict the most probable faulty sensors, which are subject to the initial probabilities defined for the failures. The method developed in this work is based on a model-based approach and provides the faulty sensors (if any), which can be logically inferred from the model of the system and the sensor readings (observations). The method is also more suitable for the systems when it is hard, or even impossible, to find the probability functions of the system. The method starts by a new mathematical description of the problem and develops a very efficient and systematic algorithm for its solution. The method builds on the concepts of analytical redundant relations (ARRs).

  4. Young adult e-cigarette use outcome expectancies: Validity of a revised scale and a short scale.

    PubMed

    Pokhrel, Pallav; Lam, Tony H; Pagano, Ian; Kawamoto, Crissy T; Herzog, Thaddeus A

    2018-03-01

    The revised youth e-cigarette outcome expectancies measure adds new items informed by recent qualitative research with young adult e-cigarette users, especially in the domain of positive "smoking" experience. Positive "smoking" experience represents beliefs that use of e-cigarettes provides outcomes associated with a better "smoking" alternative: for example, an alternative that is more socially approved, more suitable for indoor use, and that provides a safer means of enjoying nicotine. In addition, we tested a short, 8-item version of the measure which may be more easily incorporated into surveys. We tested the validity of the revised measure, both long and short versions, in terms of factor structure and associations of the expectancy factors with current e-cigarette use, e-cigarette use susceptibility, and e-cigarette use dependence. Participants were young adults (N=470; 65% women; mean age=20.9, SD=2.1). Results replicated the findings of the previous study as well as highlighted the importance of the added domain of positive "smoking" experience and the validity of the short scale. Furthermore, results showed that positive outcome expectancies are strongly associated with e-cigarette use dependence. The long and short versions of the revised youth e-cigarette outcome expectancies scale appear to be valid and useful for application not only among cigarette smokers and e-cigarette users but also among never smokers and never e-cigarette users. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Upper Atmosphere Research Satellite Validation Workshop III: Temperature and Constituents Validation

    NASA Technical Reports Server (NTRS)

    Grose, William L. (Editor); Gille, John (Editor)

    1995-01-01

    The Upper Atmosphere Research Satellite (UARS) was launched in September 1991. Since that time data have been retrieved continuously from the various instruments on the UARS spacecraft. These data have been processed by the respective instrument science teams and subsequently archived in the UARS Central Data Handling Facility (CDHF) at the NASA Goddard Space Flight Center, Greenbelt, Maryland. This report contains the proceedings from one of the three workshops held to evaluate the progress in validating UARS constituents and temperature data and to document the quality of that data. The first workshop was held in Oxford, England, in March 1992, five and one-half months after UARS launch. The second workshop was held in Boulder, Colorado in October 1992. Since launch, the various data have undergone numerous revisions. In many instances these revisions are a result of data problems identified during the validation workshops. Thus, the formal validation effort is a continually ongoing process.

  6. A Second-Order Confirmatory Factor Analysis of the Moral Distress Scale-Revised for Nurses.

    PubMed

    Sharif Nia, Hamid; Shafipour, Vida; Allen, Kelly-Ann; Heidari, Mohammad Reza; Yazdani-Charati, Jamshid; Zareiyan, Armin

    2017-01-01

    Moral distress is a growing problem for healthcare professionals that may lead to dissatisfaction, resignation, or occupational burnout if left unattended, and nurses experience different levels of this phenomenon. This study aims to investigate the factor structure of the Persian version of the Moral Distress Scale-Revised in intensive care and general nurses. This methodological research was conducted with 771 nurses from eight hospitals in the Mazandaran Province of Iran in 2017. Participants completed the Moral Distress Scale-Revised, data collected, and factor structure assessed using the construct, convergent, and divergent validity methods. The reliability of the scale was assessed using internal consistency (Cronbach's alpha, Theta, and McDonald's omega coefficients) and construct reliability. Ethical considerations: This study was approved by the Ethics Committee of Mazandaran University of Medical Sciences. The exploratory factor analysis ( N = 380) showed that the Moral Distress Scale-Revised has five factors: lack of professional competence at work, ignoring ethical issues and patient conditions, futile care, carrying out the physician's orders without question and unsafe care, and providing care under personal and organizational pressures, which explained 56.62% of the overall variance. The confirmatory factor analysis ( N = 391) supported the five-factor solution and the second-order latent factor model. The first-order model did not show a favorable convergent and divergent validity. Ultimately, the Moral Distress Scale-Revised was found to have a favorable internal consistency and construct reliability. The Moral Distress Scale-Revised was found to be a multidimensional construct. The data obtained confirmed the hypothesis of the factor structure model with a latent second-order variable. Since the convergent and divergent validity of the scale were not confirmed in this study, further assessment is necessary in future studies.

  7. Quality measurement in the shunt treatment of hydrocephalus: analysis and risk adjustment of the Revision Quotient.

    PubMed

    Piatt, Joseph H; Freibott, Christina E

    2014-07-01

    OBJECT.: The Revision Quotient (RQ) has been defined as the ratio of the number of CSF shunt revisions to the number of new shunt insertions for a particular neurosurgical practice in a unit of time. The RQ has been proposed as a quality measure in the treatment of childhood hydrocephalus. The authors examined the construct validity of the RQ and explored the feasibility of risk stratification under this metric. The Kids' Inpatient Database for 1997, 2000, 2003, 2006, and 2009 was queried for admissions with diagnostic codes for hydrocephalus and procedural codes for CSF shunt insertion or revision. Revision quotients were calculated for hospitals that performed 12 or more shunt insertions annually. The univariate associations of hospital RQs with a variety of institutional descriptors were analyzed, and a generalized linear model of the RQ was constructed. There were 12,244 admissions (34%) during which new shunts were inserted, and there were 23,349 admissions (66%) for shunt revision. Three hundred thirty-four annual RQs were calculated for 152 different hospitals. Analysis of variance in hospital RQs over the 5 years of study data supports the construct validity of the metric. The following factors were incorporated into a generalized linear model that accounted for 41% of the variance of the measured RQs: degree of pediatric specialization, proportion of initial case mix in the infant age group, and proportion with neoplastic hydrocephalus. The RQ has construct validity. Risk adjustment is feasible, but the risk factors that were identified relate predominantly to patterns of patient flow through the health care system. Possible advantages of an alternative metric, the Surgical Activity Ratio, are discussed.

  8. A Global Lake Ecological Observatory Network (GLEON) for synthesising high-frequency sensor data for validation of deterministic ecological models

    USGS Publications Warehouse

    David, Hamilton P; Carey, Cayelan C.; Arvola, Lauri; Arzberger, Peter; Brewer, Carol A.; Cole, Jon J; Gaiser, Evelyn; Hanson, Paul C.; Ibelings, Bas W; Jennings, Eleanor; Kratz, Tim K; Lin, Fang-Pang; McBride, Christopher G.; de Motta Marques, David; Muraoka, Kohji; Nishri, Ami; Qin, Boqiang; Read, Jordan S.; Rose, Kevin C.; Ryder, Elizabeth; Weathers, Kathleen C.; Zhu, Guangwei; Trolle, Dennis; Brookes, Justin D

    2014-01-01

    A Global Lake Ecological Observatory Network (GLEON; www.gleon.org) has formed to provide a coordinated response to the need for scientific understanding of lake processes, utilising technological advances available from autonomous sensors. The organisation embraces a grassroots approach to engage researchers from varying disciplines, sites spanning geographic and ecological gradients, and novel sensor and cyberinfrastructure to synthesise high-frequency lake data at scales ranging from local to global. The high-frequency data provide a platform to rigorously validate process- based ecological models because model simulation time steps are better aligned with sensor measurements than with lower-frequency, manual samples. Two case studies from Trout Bog, Wisconsin, USA, and Lake Rotoehu, North Island, New Zealand, are presented to demonstrate that in the past, ecological model outputs (e.g., temperature, chlorophyll) have been relatively poorly validated based on a limited number of directly comparable measurements, both in time and space. The case studies demonstrate some of the difficulties of mapping sensor measurements directly to model state variable outputs as well as the opportunities to use deviations between sensor measurements and model simulations to better inform process understanding. Well-validated ecological models provide a mechanism to extrapolate high-frequency sensor data in space and time, thereby potentially creating a fully 3-dimensional simulation of key variables of interest.

  9. Detection of Overreported Psychopathology with the MMPI-2 RF Form Validity Scales

    ERIC Educational Resources Information Center

    Sellbom, Martin; Bagby, R. Michael

    2010-01-01

    We examined the utility of the validity scales on the recently released Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2 RF; Ben-Porath & Tellegen, 2008) to detect overreported psychopathology. This set of validity scales includes a newly developed scale and revised versions of the original MMPI-2 validity scales. We…

  10. Psychometric Characteristics of a Vocational Preference Inventory Short Form.

    ERIC Educational Resources Information Center

    Lowman, Rodney L.; Schurman, Susan J.

    1982-01-01

    The psychometric properties of a revised version of Holland's Vocational Preference Inventory were assessed using federal government employees. Factor analyses, interscale correlations, measures of internal consistency, and criterion group profiles are presented. Evidence was supportive of the validity of the revised form. (Author/BW)

  11. SensorKit: An End-to-End Solution for Environmental Sensor Networking

    NASA Astrophysics Data System (ADS)

    Silva, F.; Graham, E.; Deschon, A.; Lam, Y.; Goldman, J.; Wroclawski, J.; Kaiser, W.; Benzel, T.

    2008-12-01

    Modern day sensor network technology has shown great promise to transform environmental data collection. However, despite the promise, these systems have remained the purview of the engineers and computer scientists who design them rather than a useful tool for the environmental scientists who need them. SensorKit is conceived of as a way to make wireless sensor networks accessible to The People: it is an advanced, powerful tool for sensor data collection that does not require advanced technological know-how. We are aiming to make wireless sensor networks for environmental science as simple as setting up a standard home computer network by providing simple, tested configurations of commercially-available hardware, free and easy-to-use software, and step-by-step tutorials. We designed and built SensorKit using a simplicity-through-sophistication approach, supplying users a powerful sensor to database end-to-end system with a simple and intuitive user interface. Our objective in building SensorKit was to make the prospect of using environmental sensor networks as simple as possible. We built SensorKit from off the shelf hardware components, using the Compact RIO platform from National Instruments for data acquisition due to its modular architecture and flexibility to support a large number of sensor types. In SensorKit, we support various types of analog, digital and networked sensors. Our modular software architecture allows us to abstract sensor details and provide users a common way to acquire data and to command different types of sensors. SensorKit is built on top of the Sensor Processing and Acquisition Network (SPAN), a modular framework for acquiring data in the field, moving it reliably to the scientist institution, and storing it in an easily-accessible database. SPAN allows real-time access to the data in the field by providing various options for long haul communication, such as cellular and satellite links. Our system also features reliable data storage and transmission, using a custody transfer mechanism that ensures data is retained until successful delivery to the scientist can be confirmed. The ability for the scientist to communicate in real-time with the sensor network in the field enables remote sensor reconfiguration and system health and status monitoring. We use a spiral approach of design, test, deploy and revise, and, by going to the field frequently and getting feedback from field scientists, we have been able to include additional functionality that is useful to the scientist while ensuring SensorKit remains intuitive to operate. Users can configure, control, and monitor SensorKit using a number of tools we have developed. An intuitive user interface running on a desktop or laptop allows scientists to setup the system, add and configure sensors, and specify when and how the data will be collected. We also have a mobile version of our interface that runs on a PDA and lets scientists calibrate sensors and "tune" the system while in the field, allowing for data validation before leaving the field and returning to the research lab. SensorKit also features SensorBase, an intuitive user interface built on top of a standard SQL database, which allows scientists to store and share their data with other researchers. SensorKit has been used for diverse scientific applications and deployed throughout the world: from studying mercury cycling in rice paddies in China, to ecological research in the neotropical rainforests of Costa Rica, to monitoring the contamination of salt lakes in Argentina.

  12. Experimenting with Sensor Webs Using Earth Observing 1

    NASA Technical Reports Server (NTRS)

    Mandl, Dan

    2004-01-01

    The New Millennium Program (NMP) Earth Observing 1 ( EO-1) satellite was launched November 21, 2000 as a one year technology validation mission. After an almost flawless first year of operations, EO-1 continued to operate in a test bed d e to validate additional technologies and concepts that will be applicable to future sensor webs. A sensor web is a group of sensors, whether space-based, ground-based or air plane-based which act in a collaborative autonomous manner to produce more value than would otherwise result from the individual observations.

  13. Validity and reliability of the Malay version multidimensional scale of perceived social support (MSPSS-M) among teachers.

    PubMed

    Lee, Soo Cheng; Moy, Foong Ming; Hairi, Noran Naqiah

    2017-01-01

    The multidimensional scale of perceived social support (MSPSS) was developed to measure perceived social support. It has been translated and culturally adapted among natives literate in the Malay language. However, its psychometric properties for teachers who are majority females and married have not been assessed. This was a cross-sectional study conducted among the public secondary school teachers in the central region of Peninsular Malaysia from May to July 2013. A total of 150 and 203 teachers were recruited to perform exploratory factor analysis and confirmatory factor analysis (CFA), respectively. Reliability testing was evaluated on 141 teachers via internal consistency and two-week interval test-retest. The 12-item three-factor structure of MSPSS-M was revised to 8-item two-factor structure. The revised MSPSS-M demonstrated excellent fit in CFA with adequate divergent and convergent validity and good factor loadings (0.80-0.90). The revised MSPSS-M also displayed good internal consistency with Cronbach's alpha of 0.91, 0.93 and 0.92 and good test-retest reliability with intraclass correlation of 0.89, 0.88 and 0.88 in the total scale, family and friends factors, respectively. The revised 8-item MSPSS-M is a reliable and valid tool for assessment of perceived social support among teachers.

  14. How honest are the signals? A protocol for validating wearable sensors.

    PubMed

    Kayhan, Varol Onur; Chen, Zheng Chris; French, Kimberly A; Allen, Tammy D; Salomon, Kristen; Watkins, Alison

    2018-02-01

    There is growing interest among organizational researchers in tapping into alternative sources of data beyond self-reports to provide a new avenue for measuring behavioral constructs. Use of alternative data sources such as wearable sensors is necessary for developing theory and enhancing organizational practice. Although wearable sensors are now commercially available, the veracity of the data they capture is largely unknown and mostly based on manufacturers' claims. The goal of this research is to test the validity and reliability of data captured by one such wearable badge (by Humanyze) in the context of structured meetings where all individuals wear a badge for the duration of the encounter. We developed a series of studies, each targeting a specific sensor of this badge that is relevant for structured meetings, and we make specific recommendations for badge data usage based on our validation results. We have incorporated the insights from our studies on a website that researchers can use to conduct validation tests for their badges, upload their data, and assess the validity of the data. We discuss this website in the corresponding studies.

  15. SIMBIOS Normalized Water-Leaving Radiance Calibration and Validation: Sensor Response, Atmospheric Corrections, Stray Light and Sun Glint. Chapter 14

    NASA Technical Reports Server (NTRS)

    Mueller, James L.

    2001-01-01

    This Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) contract supports acquisition of match up radiometric and bio-optical data for validation of Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) and other ocean color satellites, and evaluation of uncertainty budgets and protocols for in situ measurements of normalized water leaving radiances.

  16. Further development of the talent development environment questionnaire for sport.

    PubMed

    Li, Chunxiao; Wang, Chee Keng John; Pyun, Do Young; Martindale, Russell

    2015-01-01

    Given the significance of monitoring the critical environmental factors that facilitate athlete performance, this two-phase research aimed to validate and refine the revised talent development environment questionnaire (TDEQ). The TDEQ is a multidimensional self-report scale that assesses talented athletes' environmental experiences. Study 1 (the first phase) involved the examination of the revised TDEQ through an exploratory factor analysis (n = 363). This exploratory investigation identified a 28-item five-factor structure (i.e., TDEQ-5) with adequate internal consistency. Study 2 (the second phase) examined the factorial structure of the TDEQ-5, including convergent validity, discriminant validity, and group invariance (i.e., gender and sports type). The second phase was carried out with 496 talented athletes through the application of confirmatory factor analyses and multigroup invariance tests. The results supported the convergent validity, discriminant validity, and group invariance of the TDEQ-5. In conclusion, the TDEQ-5 with 25 items appears to be a reliable and valid scale for use in talent development environments.

  17. Development and validation of a cerebral oximeter capable of absolute accuracy.

    PubMed

    MacLeod, David B; Ikeda, Keita; Vacchiano, Charles; Lobbestael, Aaron; Wahr, Joyce A; Shaw, Andrew D

    2012-12-01

    Cerebral oximetry may be a valuable monitor, but few validation data are available, and most report the change from baseline rather than absolute accuracy, which may be affected by individuals whose oximetric values are outside the expected range. The authors sought to develop and validate a cerebral oximeter capable of absolute accuracy. An in vivo research study. A university human physiology laboratory. Healthy human volunteers were enrolled in calibration and validation studies of 2 cerebral oximetric sensors, the Nonin 8000CA and 8004CA. The 8000CA validation study identified 5 individuals with atypical cerebral oxygenation values; their data were used to design the 8004CA sensor, which subsequently underwent calibration and validation. Volunteers were taken through a stepwise hypoxia protocol to a minimum saturation of peripheral oxygen. Arteriovenous saturation (70% jugular bulb venous saturation and 30% arterial saturation) at 6 hypoxic plateaus was used as the reference value for the cerebral oximeter. Absolute accuracy was defined using a combination of the bias and precision of the paired saturations (A(RMS)). In the validation study for the 8000CA sensor (n = 9, 106 plateaus), relative accuracy was an A(RMS) of 2.7, with an absolute accuracy of 8.1, meeting the criteria for a relative (trend) monitor, but not an absolute monitor. In the validation study for the 8004CA sensor (n = 11, 119 plateaus), the A(RMS) of the 8004CA was 4.1, meeting the prespecified success criterion of <5.0. The Nonin cerebral oximeter using the 8004CA sensor can provide absolute data on regional cerebral saturation compared with arteriovenous saturation, even in subjects previously shown to have values outside the normal population distribution curves. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. The Revised Perceived Environmental Control Measure: A Review and Analysis.

    ERIC Educational Resources Information Center

    Smith-Sebasto, N. J.

    1992-01-01

    A study reveals the need for extensive refinement of the Revised Perceived Environmental Control Measure purported in the past to be a reliable and valid instrument to measure the relationship between the psychological construct, "locus of control," and environmental action or environmentally responsible behavior. (MCO)

  19. 14 CFR 26.23 - Extended limit of validity.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... revision or supplement, as applicable, to the Airworthiness Limitations section (ALS) of the Instructions... Oversight Office for approval. The revised ALS or supplement to the ALS must include the applicable extended... documented as airworthiness limitation items in the ALS and submitted to the FAA Oversight Office for...

  20. 14 CFR 26.23 - Extended limit of validity.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... revision or supplement, as applicable, to the Airworthiness Limitations section (ALS) of the Instructions... Oversight Office for approval. The revised ALS or supplement to the ALS must include the applicable extended... documented as airworthiness limitation items in the ALS and submitted to the FAA Oversight Office for...

  1. 14 CFR 26.23 - Extended limit of validity.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... revision or supplement, as applicable, to the Airworthiness Limitations section (ALS) of the Instructions... Oversight Office for approval. The revised ALS or supplement to the ALS must include the applicable extended... documented as airworthiness limitation items in the ALS and submitted to the FAA Oversight Office for...

  2. 14 CFR 26.23 - Extended limit of validity.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... revision or supplement, as applicable, to the Airworthiness Limitations section (ALS) of the Instructions... Oversight Office for approval. The revised ALS or supplement to the ALS must include the applicable extended... documented as airworthiness limitation items in the ALS and submitted to the FAA Oversight Office for...

  3. The Wechsler Memory Scale: A Review of Research.

    ERIC Educational Resources Information Center

    Ivison, David

    1990-01-01

    Research on the standardization, reliability, validity, factor structure, and subtests of the Wechsler Memory Scale (WMS) (1945) and its revised version (1987) is reviewed. Much research relating to the WMS appears to be relevant to the revised version. Use of the instrument in Australia is discussed. (SLD)

  4. A Lewinian Perspective on Taking Conflict Personally: Revision, Refinement, and Validation of the Instrument.

    ERIC Educational Resources Information Center

    Hample, Dale; Dallinger, Judith M.

    1995-01-01

    Describes theoretical connections among field theory, defensiveness, attributions, and taking conflict personally (TCP). Revises the original version of a multidimensional TCP scale, measuring six TCP subscales: direct personalization, persecution feelings, stress reaction, positive relational effects, negative relational effects, and like/dislike…

  5. Assessing Arthroscopic Skills Using Wireless Elbow-Worn Motion Sensors.

    PubMed

    Kirby, Georgina S J; Guyver, Paul; Strickland, Louise; Alvand, Abtin; Yang, Guang-Zhong; Hargrove, Caroline; Lo, Benny P L; Rees, Jonathan L

    2015-07-01

    Assessment of surgical skill is a critical component of surgical training. Approaches to assessment remain predominantly subjective, although more objective measures such as Global Rating Scales are in use. This study aimed to validate the use of elbow-worn, wireless, miniaturized motion sensors to assess the technical skill of trainees performing arthroscopic procedures in a simulated environment. Thirty participants were divided into three groups on the basis of their surgical experience: novices (n = 15), intermediates (n = 10), and experts (n = 5). All participants performed three standardized tasks on an arthroscopic virtual reality simulator while wearing wireless wrist and elbow motion sensors. Video output was recorded and a validated Global Rating Scale was used to assess performance; dexterity metrics were recorded from the simulator. Finally, live motion data were recorded via Bluetooth from the wireless wrist and elbow motion sensors and custom algorithms produced an arthroscopic performance score. Construct validity was demonstrated for all tasks, with Global Rating Scale scores and virtual reality output metrics showing significant differences between novices, intermediates, and experts (p < 0.001). The correlation of the virtual reality path length to the number of hand movements calculated from the wireless sensors was very high (p < 0.001). A comparison of the arthroscopic performance score levels with virtual reality output metrics also showed highly significant differences (p < 0.01). Comparisons of the arthroscopic performance score levels with the Global Rating Scale scores showed strong and highly significant correlations (p < 0.001) for both sensor locations, but those of the elbow-worn sensors were stronger and more significant (p < 0.001) than those of the wrist-worn sensors. A new wireless assessment of surgical performance system for objective assessment of surgical skills has proven valid for assessing arthroscopic skills. The elbow-worn sensors were shown to achieve an accurate assessment of surgical dexterity and performance. The validation of an entirely objective assessment of arthroscopic skill with wireless elbow-worn motion sensors introduces, for the first time, a feasible assessment system for the live operating theater with the added potential to be applied to other surgical and interventional specialties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  6. The Consequences of Consequential Validity.

    ERIC Educational Resources Information Center

    Mehrens, William A.

    1997-01-01

    There is no agreement at present about the importance or meaning of the term "consequential validity." It is important that the authors of revisions to the "Standards for Educational and Psychological Testing" recognize the debate and relegate discussion of consequences to a context separate from the discussion of validity.…

  7. Common Criteria related security design patterns--validation on the intelligent sensor example designed for mine environment.

    PubMed

    Bialas, Andrzej

    2010-01-01

    The paper discusses the security issues of intelligent sensors that are able to measure and process data and communicate with other information technology (IT) devices or systems. Such sensors are often used in high risk applications. To improve their robustness, the sensor systems should be developed in a restricted way to provide them with assurance. One of assurance creation methodologies is Common Criteria (ISO/IEC 15408), used for IT products and systems. The contribution of the paper is a Common Criteria compliant and pattern-based method for the intelligent sensors security development. The paper concisely presents this method and its evaluation for the sensor detecting methane in a mine, focusing on the security problem of the intelligent sensor definition and solution. The aim of the validation is to evaluate and improve the introduced method.

  8. Enhanced parent selection algorithms in mintroute protocol

    NASA Astrophysics Data System (ADS)

    Kim, Ki-Il

    2012-11-01

    A low-rate, short-range wireless radio communication on a small device often hampers high reliability in wireless sensor networks. However, more applications are increasingly demanding high reliability. To meet this requirement, various approaches have been proposed in each viewpoint of layers. Among those, MintRoute is a well-known network layer approach to develop a new metric based on link quality for path selection towards the sink. By choosing the link with the highest measured value, it has a higher possibility to transmit a packet over the link without error. However, there are still several issues to be mentioned during operations. In this paper, we propose how to improve the MintRoute protocol through revised algorithms. They include a parent selection considering distance and level from the sink node, and a fast recovery method against failures. Simulations and analysis are performed by in order to validate the suitability of reduced end-to-end delay and fast recovery for failures, thus to enhance the reliability of communication.

  9. Validation of the iHealth BP7 wrist blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Wang, Qing; Zhao, Huadong; Chen, Wan; Li, Ni; Wan, Yi

    2014-02-01

    The aim of this study was to validate the iHealth BP7 wireless wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained for validation. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. The device produced 66, 87, and 97 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 72, 93, and 99 mmHg for diastolic blood pressure (DBP), respectively. The mean±SD device-observer difference was -0.7±6.9 mmHg for SBP and -1.0±5.1 mmHg for DBP. The number of participants with two or three device-observer differences within 5 mmHg was 25 for SBP and 26 for DBP; furthermore, there were three participants for SBP and one participant for DBP, with none of the device-observer differences within 5 mmHg. On the basis of the validation results, the iHealth BP7 wireless wrist blood pressure monitor can be recommended for self-measurement in an adult population.

  10. Instrument development and validation of a quality scale for historical research papers (QSHRP): a pilot study.

    PubMed

    Kelly, Jacinta; Watson, Roger

    2014-12-01

    To report a pilot study for the development and validation of an instrument to measure quality in historical research papers. There are no set criteria to assess historical papers published in nursing journals. A three phase mixed method sequential confirmatory design. In 2012, we used a three-phase approach to item generation and content evaluation. In phase 1, we consulted nursing historians using an online survey comprising three open-ended questions and revised the items. In phase 2, we evaluated the revised items for relevance with expert historians using a 4-point Likert scale and Content Validity Index calculation. In phase 3, we conducted reliability testing of the instrument using a 3-point Likert scale. In phase 1, 121 responses were generated via the online survey and revised to 40 interrogatively phrased items. In phase 2, five items with an Item Content Validity Index score of ≥0·7 remained. In phase 3, responses from historians resulted in 100% agreement to questions 1, 2 and 4 and 89% and 78%, respectively, to questions 3 and 5. Items for the QSHRP have been identified, content validated and reliability tested. This scale improves on previous scales, which over-emphasized source criticism. However, a full-scale study is needed with nursing historians to increase its robustness. © 2014 John Wiley & Sons Ltd.

  11. Contributions of the SDR Task Network tool to Calibration and Validation of the NPOESS Preparatory Project instruments

    NASA Astrophysics Data System (ADS)

    Feeley, J.; Zajic, J.; Metcalf, A.; Baucom, T.

    2009-12-01

    The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP) Calibration and Validation (Cal/Val) team is planning post-launch activities to calibrate the NPP sensors and validate Sensor Data Records (SDRs). The IPO has developed a web-based data collection and visualization tool in order to effectively collect, coordinate, and manage the calibration and validation tasks for the OMPS, ATMS, CrIS, and VIIRS instruments. This tool is accessible to the multi-institutional Cal/Val teams consisting of the Prime Contractor and Government Cal/Val leads along with the NASA NPP Mission team, and is used for mission planning and identification/resolution of conflicts between sensor activities. Visualization techniques aid in displaying task dependencies, including prerequisites and exit criteria, allowing for the identification of a critical path. This presentation will highlight how the information is collected, displayed, and used to coordinate the diverse instrument calibration/validation teams.

  12. Psychometric Properties of the "Miranda Rights Comprehension Instruments" with a Juvenile Justice Sample

    ERIC Educational Resources Information Center

    Goldstein, Naomi E. Sevin; Romaine, Christina L. Riggs; Zelle, Heather; Kalbeitzer, Rachel; Mesiarik, Constance; Wolbransky, Melinda

    2011-01-01

    This article describes the psychometric properties of the "Miranda Rights Comprehension Instruments", the revised version of Grisso's "Miranda" instruments. The original instruments demonstrated good reliability and validity in a normative sample. The revised instruments updated the content of the original instruments and were…

  13. The Career Futures Inventory-Revised: Measuring Dimensions of Career Adaptability

    ERIC Educational Resources Information Center

    Rottinghaus, Patrick J.; Buelow, Kristine L.; Matyja, Anna; Schneider, Madalyn R.

    2012-01-01

    This study reports the development and initial validation of the "Career Futures Inventory-Revised" (CFI-R) in two large samples of university students. The 28-item CFI-R assesses aspects of career adaptability, including positive career planning attitudes, general outcome expectations, and components of Parsons' tripartite model and…

  14. Psychometric Properties of the Revised Mathematics Anxiety Rating Scale

    ERIC Educational Resources Information Center

    Baloglu, Mustafa; Zelhart, Paul F.

    2007-01-01

    An exploratory factor analysis and several confirmatory analyses were performed to evaluate the factorial structure of the Revised Mathematics Anxiety Rating Scale (RMARS) through the responses of 805 college students. On 559 students' scores, the instrument's construct validity was tested through a confirmatory factor analysis (CFA) and was found…

  15. 40 CFR 63.2269 - What are my monitoring installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... temperature sensor in a position that provides a representative temperature. (2) Use a temperature sensor with... owners manual. Following the electronic calibration, you must conduct a temperature sensor validation check in which a second or redundant temperature sensor placed nearby the process temperature sensor...

  16. 40 CFR 63.2269 - What are my monitoring installation, operation, and maintenance requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... temperature sensor in a position that provides a representative temperature. (2) Use a temperature sensor with... owners manual. Following the electronic calibration, you must conduct a temperature sensor validation check in which a second or redundant temperature sensor placed nearby the process temperature sensor...

  17. Applications of artificial intelligence to space station: General purpose intelligent sensor interface

    NASA Technical Reports Server (NTRS)

    Mckee, James W.

    1988-01-01

    This final report describes the accomplishments of the General Purpose Intelligent Sensor Interface task of the Applications of Artificial Intelligence to Space Station grant for the period from October 1, 1987 through September 30, 1988. Portions of the First Biannual Report not revised will not be included but only referenced. The goal is to develop an intelligent sensor system that will simplify the design and development of expert systems using sensors of the physical phenomena as a source of data. This research will concentrate on the integration of image processing sensors and voice processing sensors with a computer designed for expert system development. The result of this research will be the design and documentation of a system in which the user will not need to be an expert in such areas as image processing algorithms, local area networks, image processor hardware selection or interfacing, television camera selection, voice recognition hardware selection, or analog signal processing. The user will be able to access data from video or voice sensors through standard LISP statements without any need to know about the sensor hardware or software.

  18. Measuring Patient Mobility in the ICU Using a Novel Noninvasive Sensor.

    PubMed

    Ma, Andy J; Rawat, Nishi; Reiter, Austin; Shrock, Christine; Zhan, Andong; Stone, Alex; Rabiee, Anahita; Griffin, Stephanie; Needham, Dale M; Saria, Suchi

    2017-04-01

    To develop and validate a noninvasive mobility sensor to automatically and continuously detect and measure patient mobility in the ICU. Prospective, observational study. Surgical ICU at an academic hospital. Three hundred sixty-two hours of sensor color and depth image data were recorded and curated into 109 segments, each containing 1,000 images, from eight patients. None. Three Microsoft Kinect sensors (Microsoft, Beijing, China) were deployed in one ICU room to collect continuous patient mobility data. We developed software that automatically analyzes the sensor data to measure mobility and assign the highest level within a time period. To characterize the highest mobility level, a validated 11-point mobility scale was collapsed into four categories: nothing in bed, in-bed activity, out-of-bed activity, and walking. Of the 109 sensor segments, the noninvasive mobility sensor was developed using 26 of these from three ICU patients and validated on 83 remaining segments from five different patients. Three physicians annotated each segment for the highest mobility level. The weighted Kappa (κ) statistic for agreement between automated noninvasive mobility sensor output versus manual physician annotation was 0.86 (95% CI, 0.72-1.00). Disagreement primarily occurred in the "nothing in bed" versus "in-bed activity" categories because "the sensor assessed movement continuously," which was significantly more sensitive to motion than physician annotations using a discrete manual scale. Noninvasive mobility sensor is a novel and feasible method for automating evaluation of ICU patient mobility.

  19. Validation of Self-Reported Cognitive Problems with Objective Neuropsychological Performance in Manganese-Exposed Residents

    EPA Science Inventory

    There is a lack of validation of self-reported cognitive problems with objective neuropsychological measures. The validity of four self-reported cognitive items from a health questionnaire (HQ) and the Symptoms Checklist 90-Revised (SCL-90-R) was examined with objective clinical ...

  20. Teacher Immediacy Scales: Testing for Validity across Cultures

    ERIC Educational Resources Information Center

    Zhang, Qin; Oetzel, John G.; Gao, Xiaofang; Wilcox, Richard G.; Takai, Jiro

    2007-01-01

    Cross-cultural validity of teacher immediacy scales is a constant concern in instructional communication research. The present study examines the validity of two existing teacher immediacy scales: the Revised Nonverbal Immediacy Measure (RNIM) and the Chinese Teacher Immediacy Scale (CTIS) in U.S., Chinese, German, and Japanese cultures. Results…

  1. Initial Teacher Licensure Testing in Tennessee: Test Validation.

    ERIC Educational Resources Information Center

    Bowman, Harry L.; Petry, John R.

    In 1988 a study was conducted to determine the validity of candidate teacher licensure examinations for use in Tennessee under the 1984 Comprehensive Education Reform Act. The Department of Education conducted a study to determine the validity of 11 previously unvalidated or extensively revised tests for certification and to make recommendations…

  2. [The School Refusal Assessment Scale: Psychometric properties and validation of a modified version].

    PubMed

    Knollmann, Martin; Sicking, Alexander; Hebebrand, Johannes; Reissner, Volker

    2017-07-01

    Psychometric properties of the original and a modified version of the «Einschätzungsskala der Schulverweigerung» (German version of the School Refusal Assessment Scale, SRAS; Kearney & Silverman, 1993; Overmeyer et al., 1994) were analyzed in order to identify alternative ways to revise the SRAS/ESV compared to the existing revision SRAS-R (Kearney, 2002). The SRAS/ESV consists of a parent and a child version and measures four functions of school refusal (avoidance of negative affect related to school settings, escape from aversive social or evaluative situations, attention-getting behavior, positive tangible reinforcement). Data from N = 124 (parent version) respectively N = 156 (child version) patients of a specialized psychiatric outpatient unit for children and adolescents with school-avoiding behavior were obtained. Analyzes included characteristics of items and scales, face-, factorial-, and construct-validity (correlations with other questionnaires, e. g., YSR, CBCL were analyzed). Many items seem to measure overall anxiety instead of the functional aspects of school refusal, one item measures expansive behavior. Four factors were obtained, but they did not reflect the assumed structure of the ESV (e. g., overlap of the two avoidance-related scales). Post-hoc-analyzes with a modified version (elimination of several items with problematic content validity) suggested three factors, convergent and discriminative validity of the modified version was confirmed. Because only some of the afore-mentioned problems have been addressed in the revised version (SRAS-R; Kearney, 2002), a new revision and extension of the German version of the questionnaire covering more aspects of school avoidance behavior (e. g., bullying, depression, somatic complaints, psychosocial factors) is discussed.

  3. Satellite and airborne IR sensor validation by an airborne interferometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gumley, L.E.; Delst, P.F. van; Moeller, C.C.

    1996-11-01

    The validation of in-orbit longwave IR radiances from the GOES-8 Sounder and inflight longwave IR radiances from the MODIS Airborne Simulator (MAS) is described. The reference used is the airborne University of Wisconsin High Resolution Interferometer Sounder (HIS). The calibration of each sensor is described. Data collected during the Ocean Temperature Interferometric Survey (OTIS) experiment in January 1995 is used in the comparison between sensors. Detailed forward calculations of at-sensor radiance are used to account for the difference in GOES-8 and HIS altitude and viewing geometry. MAS radiances and spectrally averaged HIS radiances are compared directly. Differences between GOES-8 andmore » HIS brightness temperatures, and GOES-8 and MAS brightness temperatures, are found to be with 1.0 K for the majority of longwave channels examined. The same validation approach will be used for future sensors such as the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Atmospheric Infrared Sounder (AIRS). 11 refs., 2 figs., 4 tabs.« less

  4. Tablet PC Enabled Body Sensor System for Rural Telehealth Applications

    PubMed Central

    Panicker, Nitha V.; Kumar, A. Sukesh

    2016-01-01

    Telehealth systems benefit from the rapid growth of mobile communication technology for measuring physiological signals. Development and validation of a tablet PC enabled noninvasive body sensor system for rural telehealth application are discussed in this paper. This system includes real time continuous collection of physiological parameters (blood pressure, pulse rate, and temperature) and fall detection of a patient with the help of a body sensor unit and wireless transmission of the acquired information to a tablet PC handled by the medical staff in a Primary Health Center (PHC). Abnormal conditions are automatically identified and alert messages are given to the medical officer in real time. Clinical validation is performed in a real environment and found to be successful. Bland-Altman analysis is carried out to validate the wrist blood pressure sensor used. The system works well for all measurements. PMID:26884757

  5. Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.

    PubMed

    Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi

    2016-08-01

    The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.

  6. Validation of the Abdominal Pain Index Using a Revised Scoring Method

    PubMed Central

    Sherman, Amanda L.; Smith, Craig A.; Walker, Lynn S.

    2015-01-01

    Objective Evaluate the psychometric properties of child- and parent-report versions of the four-item Abdominal Pain Index (API) in children with functional abdominal pain (FAP) and healthy controls, using a revised scoring method that facilitates comparisons of scores across samples and time. Methods Pediatric patients aged 8–18 years with FAP and controls completed the API at baseline (N = 1,967); a subset of their parents (N = 290) completed the API regarding the child’s pain. Subsets of patients completed follow-up assessments at 2 weeks (N = 231), 3 months (N = 330), and 6 months (N = 107). Subsets of both patients (N = 389) and healthy controls (N = 172) completed a long-term follow-up assessment (mean age at follow-up = 20.21 years, SD = 3.75). Results The API demonstrated good concurrent, discriminant, and construct validity, as well as good internal consistency. Conclusion We conclude that the API, using the revised scoring method, is a useful, reliable, and valid measure of abdominal pain severity. PMID:25617048

  7. Remote Sensing Product Verification and Validation at the NASA Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stanley, Thomas M.

    2005-01-01

    Remote sensing data product verification and validation (V&V) is critical to successful science research and applications development. People who use remote sensing products to make policy, economic, or scientific decisions require confidence in and an understanding of the products' characteristics to make informed decisions about the products' use. NASA data products of coarse to moderate spatial resolution are validated by NASA science teams. NASA's Stennis Space Center (SSC) serves as the science validation team lead for validating commercial data products of moderate to high spatial resolution. At SSC, the Applications Research Toolbox simulates sensors and targets, and the Instrument Validation Laboratory validates critical sensors. The SSC V&V Site consists of radiometric tarps, a network of ground control points, a water surface temperature sensor, an atmospheric measurement system, painted concrete radial target and edge targets, and other instrumentation. NASA's Applied Sciences Directorate participates in the Joint Agency Commercial Imagery Evaluation (JACIE) team formed by NASA, the U.S. Geological Survey, and the National Geospatial-Intelligence Agency to characterize commercial systems and imagery.

  8. Common Criteria Related Security Design Patterns—Validation on the Intelligent Sensor Example Designed for Mine Environment

    PubMed Central

    Bialas, Andrzej

    2010-01-01

    The paper discusses the security issues of intelligent sensors that are able to measure and process data and communicate with other information technology (IT) devices or systems. Such sensors are often used in high risk applications. To improve their robustness, the sensor systems should be developed in a restricted way to provide them with assurance. One of assurance creation methodologies is Common Criteria (ISO/IEC 15408), used for IT products and systems. The contribution of the paper is a Common Criteria compliant and pattern-based method for the intelligent sensors security development. The paper concisely presents this method and its evaluation for the sensor detecting methane in a mine, focusing on the security problem of the intelligent sensor definition and solution. The aim of the validation is to evaluate and improve the introduced method. PMID:22399888

  9. L-band HIgh Spatial Resolution Soil Moisture Mapping using SMALL UnManned Aerial Systems

    NASA Astrophysics Data System (ADS)

    Dai, E.; Venkitasubramony, A.; Gasiewski, A. J.; Stachura, M.; Elston, J. S.; Walter, B.; Lankford, D.; Corey, C.

    2017-12-01

    Soil moisture is of fundamental importance to many hydrological, biological and biogeochemical processes, plays an important role in the development and evolution of convective weather and precipitation, water resource management, agriculture, and flood runoff prediction. The launch of NASA's Soil Moisture Active/Passive (SMAP) mission in 2015 provided new passive global measurements of soil moisture and surface freeze/thaw state at fixed crossing times and spatial resolutions of 36 km. However, there exists a need for measurements of soil moisture on much smaller spatial scales and arbitrary diurnal times for SMAP validation, precision agriculture and evaporation and transpiration studies of boundary layer heat transport. The Lobe Differencing Correlation Radiometer (LDCR) provides a means of mapping soil moisture on spatial scales as small as several meters. Compared with other methods of validation based on either in-situ measurements [1,2] or existing airborne sensors suitable for manned aircraft deployment [3], the integrated design of the LDCR on a lightweight small UAS (sUAS) is capable of providing sub-watershed ( km scale) coverage at very high spatial resolution ( 15 m) suitable for scaling studies, and at comparatively low operator cost. To demonstrate the LDCR several flights had been performed during field experiments at the Canton Oklahoma Soilscape site and Yuma Colorado Irrigation Research Foundation (IRF) site in 2015 and 2016, respectively, using LDCR Revision A and Tempest sUAS. The scientific intercomparisons of LDCR retrieved soil moisture and in-situ measurements will be presented. LDCR Revision B has been built and integrated into SuperSwift sUAS and additional field experiments will be performed at IRF in 2017. In Revision B the IF signal is sampled at 80 MS/s to enable digital correlation and RFI mitigation capabilities, in addition to analog correlation. [1] McIntyre, E.M., A.J. Gasiewski, and D. Manda D, "Near Real-Time Passive C-Band Microwave Soil Moisture Retrieval During CLASIC 2007," Proc. IGARSS, 2008. [2] Robock, A., S. Steele-Dunne, J. Basara, W. Crow, and M. Moghaddam M, "In Situ Network and Scaling," SMAP Algorithm and Cal/Val Workshop, 2009. [3] Walker, A., "Airborne Microwave Radiometer Measurements During CanEx-SM10," Second SMAP Cal/Val Workshop, 2011.

  10. Sensor Selection and Data Validation for Reliable Integrated System Health Management

    NASA Technical Reports Server (NTRS)

    Garg, Sanjay; Melcher, Kevin J.

    2008-01-01

    For new access to space systems with challenging mission requirements, effective implementation of integrated system health management (ISHM) must be available early in the program to support the design of systems that are safe, reliable, highly autonomous. Early ISHM availability is also needed to promote design for affordable operations; increased knowledge of functional health provided by ISHM supports construction of more efficient operations infrastructure. Lack of early ISHM inclusion in the system design process could result in retrofitting health management systems to augment and expand operational and safety requirements; thereby increasing program cost and risk due to increased instrumentation and computational complexity. Having the right sensors generating the required data to perform condition assessment, such as fault detection and isolation, with a high degree of confidence is critical to reliable operation of ISHM. Also, the data being generated by the sensors needs to be qualified to ensure that the assessments made by the ISHM is not based on faulty data. NASA Glenn Research Center has been developing technologies for sensor selection and data validation as part of the FDDR (Fault Detection, Diagnosis, and Response) element of the Upper Stage project of the Ares 1 launch vehicle development. This presentation will provide an overview of the GRC approach to sensor selection and data quality validation and will present recent results from applications that are representative of the complexity of propulsion systems for access to space vehicles. A brief overview of the sensor selection and data quality validation approaches is provided below. The NASA GRC developed Systematic Sensor Selection Strategy (S4) is a model-based procedure for systematically and quantitatively selecting an optimal sensor suite to provide overall health assessment of a host system. S4 can be logically partitioned into three major subdivisions: the knowledge base, the down-select iteration, and the final selection analysis. The knowledge base required for productive use of S4 consists of system design information and heritage experience together with a focus on components with health implications. The sensor suite down-selection is an iterative process for identifying a group of sensors that provide good fault detection and isolation for targeted fault scenarios. In the final selection analysis, a statistical evaluation algorithm provides the final robustness test for each down-selected sensor suite. NASA GRC has developed an approach to sensor data qualification that applies empirical relationships, threshold detection techniques, and Bayesian belief theory to a network of sensors related by physics (i.e., analytical redundancy) in order to identify the failure of a given sensor within the network. This data quality validation approach extends the state-of-the-art, from red-lines and reasonableness checks that flag a sensor after it fails, to include analytical redundancy-based methods that can identify a sensor in the process of failing. The focus of this effort is on understanding the proper application of analytical redundancy-based data qualification methods for onboard use in monitoring Upper Stage sensors.

  11. Cross-cultural adaptation of the Disability of Arm, Shoulder, and Hand questionnaire: Spanish for Puerto Rico Version

    PubMed Central

    Mulero-Portela, Ana L.; Colón-Santaella, Carmen L.; Cruz-Gomez, Cynthia

    2010-01-01

    The purpose of this study was to perform a cross-cultural adaptation of the Disability of Arm, Shoulder, and Hand (DASH) questionnaire to Spanish for Puerto Rico. Five steps were followed for the cross-cultural adaptation: forward translations into Spanish for Puerto Rico, synthesis of the translations, back translations into English, revision by an expert committee, and field test of the prefinal version. Psychometric characteristics of reliability and construct validity were evaluated for the final version. Internal consistency of the final version was high (Cronbach's α = 0.97) and item-to-total correlations were moderate (range from 0.44 to 0.85). Construct validity was evaluated by correlating the DASH with the scales of the Functional Assessment of Cancer Therapy - Breast. Fair to moderate correlations found in this study between the DASH and most scales of the Functional Assessment of Cancer Therapy - Breast support the construct validity of the Puerto Rico-Spanish DASH. The final version of the questionnaire was revised and approved by the Institute for Work and Health of Canada. Revisions to the original DASH English version are recommended. This version of the DASH is valid and reliable, and it can be used to evaluate outcomes in both clinical and research settings. PMID:19901616

  12. Continued Development of Compact Multi-Gas Monitor for Life Support Systems Control in Space

    NASA Technical Reports Server (NTRS)

    Delgado-Alonso, Jesus; Phillips, Straun; Berry, David; DiCarmine, Paul; Chullen, Cinda; Quinn, Gregory

    2016-01-01

    Miniature optical gas sensors based on luminescent materials have shown great potential as alternatives to NIR-based gas sensor systems for the Portable Life Support System (PLSS). The unique capability of luminescent sensors for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages over both traditional and advanced non-dispersive infrared (NDIR) gas sensors, which have so far shown longer life than luminescent sensors. In this paper we present the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted in Intelligent Optical Systems laboratories, a United Technologies Corporation Aerospace Systems (UTC) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems, and the advantages and limitations found through detailed sensor validation are discussed.

  13. Incremental validity of the Minnesota Multiphasic Personality Inventory-2 and symptom checklist-90-revised with mental health inpatients.

    PubMed

    Simonds, Elise C; Handel, Richard W; Archer, Robert P

    2008-03-01

    This study evaluated the incremental validity of scores from the Minnesota Multiphasic Personality Inventory-2 (MMPI-2) and the Symptom Checklist-90-Revised (SCL-90-R) in a sample of mental health inpatients originally published by Archer, Griffin, and Aiduk (1995). The incremental validity of scores from the SCL-90-R primary symptom dimensions and MMPI-2 Clinical, Content, and Restructured Clinical scales was assessed in a sample of 544 mental health inpatients using conceptually related items from the Brief Psychiatric Rating Scale (BPRS) as criteria. A series of hierarchical multiple regressions indicated that scores from the SCL-90-R primary symptom dimensions exhibited limited incremental validity (Mdn DeltaR(2) = .01, range = 0-.01), whereas scores from MMPI-2 scales contributed additional information in the prediction of ratings on all but one BPRS item (Mdn DeltaR( 2) = .08, range = .04-.12).

  14. Psychometric evaluation of the Revised Professional Practice Environment (RPPE) scale.

    PubMed

    Erickson, Jeanette Ives; Duffy, Mary E; Ditomassi, Marianne; Jones, Dorothy

    2009-05-01

    The purpose was to examine the psychometric properties of the Revised Professional Practice Environment (RPPE) scale. Despite renewed focus on studying health professionals' practice environments, there are still few reliable and valid instruments available to assist nurse administrators in decision making. A psychometric evaluation using a random-sample cross-validation procedure (calibration sample [CS], n = 775; validation sample [VS], n = 775) was undertaken. Cronbach alpha internal consistency reliability of the total score (r = 0.93 [CS] and 0.92 [VS]), resulting subscale scores (r range: 0.80-0.87 [CS], 0.81-0.88 [VS]), and principal components analyses with Varimax rotation and Kaiser normalization (8 components, 59.2% variance [CS], 59.7% [VS]) produced almost identical results in both samples. The multidimensional RPPE is a psychometrically sound measure of 8 components of the professional practice environment in the acute care setting and sufficiently reliable and valid for use as independent subscales in healthcare research.

  15. Identifying Careless Responding With the Psychopathic Personality Inventory-Revised Validity Scales.

    PubMed

    Marcus, David K; Church, Abere Sawaqdeh; O'Connell, Debra; Lilienfeld, Scott O

    2018-01-01

    The Psychopathic Personality Inventory-Revised (PPI-R) includes validity scales that assess Deviant Responding (DR), Virtuous Responding, and Inconsistent Responding. We examined the utility of these scales for identifying careless responding using data from two online studies that examined correlates of psychopathy in college students (Sample 1: N = 583; Sample 2: N = 454). Compared with those below the cut scores, those above the cut on the DR scale yielded consistently lower validity coefficients when PPI-R scores were correlated with corresponding scales from the Triarchic Psychopathy Measure. The other three PPI-R validity scales yielded weaker and less consistent results. Participants who completed the studies in an inordinately brief amount of time scored significantly higher on the DR and Virtuous Responding scales than other participants. Based on the findings from the current studies, researchers collecting PPI-R data online should consider identifying and perhaps screening out respondents with elevated scores on the DR scale.

  16. Validity of Factors of the Psychopathy Checklist–Revised in Female Prisoners

    PubMed Central

    Kennealy, Patrick J.; Hicks, Brian M.; Patrick, Christopher J.

    2008-01-01

    The validity of the Psychopathy Checklist–Revised (PCL-R) has been examined extensively in men, but its validity for women remains understudied. Specifically, the correlates of the general construct of psychopathy and its components as assessed by PCL-R total, factor, and facet scores have yet to be examined in depth. Based on previous research conducted with male offenders, a large female inmate sample was used to examine the patterns of relations between total, factor, and facet scores on the PCL-R and various criterion variables. These variables include ratings of psychopathy based on Cleckley’s criteria, symptoms of antisocial personality disorder, and measures of substance use and abuse, criminal behavior, institutional misconduct, interpersonal aggression, normal range personality, intellectual functioning, and social background variables. Results were highly consistent with past findings in male samples and provide further evidence for the construct validity of the PCL-R two-factor and four-facet models across genders. PMID:17986651

  17. Moral Distress Scale for Occupational Therapists: Part 1. Instrument Development and Content Validity.

    PubMed

    Penny, Neil H; Bires, Samantha J; Bonn, Elizabeth A; Dockery, Alisha N; Pettit, Nicole L

    2016-01-01

    We describe the development of an instrument to measure moral distress experienced by occupational therapists and show how its content validity was established. Written comments (n = 78) from a previous survey using the Moral Distress Scale-Revised-Other Health Provider Adult were used to modify that instrument and create the Moral Distress Scale-Revised-Occupational Therapy-Adult Settings (MDS-R-OT[A]). The MDS-R-OT[A] was distributed to a nationwide random sample of 400 occupational therapists who rated the relevance of each item to their clinical practice. A scale content validity index of 81.8% was found (geriatric = 81.5%, physical disability = 80.8%, combination of the two = 85.7%). The MDS-R-OT[A] possesses acceptable content validity and is appropriate for use with occupational therapists working in geriatric or physical disability settings. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  18. The psychometrics and validity of the Junior Temperament and Character Inventory in Portuguese adolescents.

    PubMed

    Moreira, Paulo A; Oliveira, João Tiago; Cloninger, Kevin M; Azevedo, Carla; Sousa, Alexandra; Castro, Jorge; Cloninger, C Robert

    2012-11-01

    Personality traits related to persistence and self-regulation of long-term goals can predict academic performance as well or better than measures of intelligence. The 5-factor model has been suggested to outperform some other personality tests in predicting academic performance, but it has not been compared to Cloninger's psychobiological model for this purpose. The aims of this study were, first, to evaluate the psychometric properties of the Junior Temperament and Character Inventory (JTCI) in adolescents in Portugal, and second, to evaluate the comparative validity of age-appropriate versions of Cloninger's 7-factor psychobiological model, Costa and McCrae's five-factor NEO-Personality Inventory-Revised, and Cattell's 16-personality-factor inventory in predicting academic achievement. All dimensions of the Portuguese JTCI had moderate to strong internal consistency. The Cattell's sixteen-personality-factor and NEO inventories provided strong construct validity for the JTCI in students younger than 17 years and for the revised adult version (TCI-Revised) in those 17 years and older. High TCI Persistence predicted school grades regardless of age as much or more than intelligence. High TCI Harm Avoidance, high Self-Transcendence, and low TCI Novelty Seeking were additional predictors in students older than 17. The psychobiological model, as measured by the JTCI and TCI-Revised, performed as well or better than other measures of personality or intelligence in predicting academic achievement. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Psychometric Properties of the Persian Version of the Difficulties in Emotion Regulation Scale) DERS-6 & DERS-5- Revised (in an Iranian Clinical Sample.

    PubMed

    Mazaheri, Mina

    2015-04-01

    The purpose of this study was to determine the construct validity and reliability of the two forms of the Persian version of the Difficulties in Emotion Regulation Scale (DERS-6 & DERS-5-revised) in a clinical sample. The clinical sample consisted of 181 patients diagnosed with Functional GI Disorders (FGID) who referred to the digestive psychosomatic clinic in Isfahan in 2012. They were selected by census method (In a given period of time). The Persian version of the DERS, the short form of the DASS, and the TAS-20 were used to collect data. The results of the factor structure or construct validity using principal components analysis with varimax rotation recognized 7 factors for the DERS-6 (Goals, Awarness, Impalse, Non Acceptance, Strategy, Clarity, Recognition), and 6 factors for the DERS-5- revised (Non Acceptance, Goals, Impalse, Strategy, Clarity, Recognition) in the clinical sample. They showed the common variance of 59.51% and 59.15%, respectively. Also, the results showed that the concurrent validity of both forms of the DERS and most of their factors, and their reliability in terms of Cronbach-Alpha were favorable. Considering the factor structure and favorable psychometric properties of the two scales of DERS-6 & DERS-5-revised, the scales can be used in clinical samples.

  20. NASA sea ice and snow validation plan for the Defense Meteorological Satellite Program special sensor microwave/imager

    NASA Technical Reports Server (NTRS)

    Cavalieri, Donald J. (Editor); Swift, Calvin T. (Editor)

    1987-01-01

    This document addresses the task of developing and executing a plan for validating the algorithm used for initial processing of sea ice data from the Special Sensor Microwave/Imager (SSMI). The document outlines a plan for monitoring the performance of the SSMI, for validating the derived sea ice parameters, and for providing quality data products before distribution to the research community. Because of recent advances in the application of passive microwave remote sensing to snow cover on land, the validation of snow algorithms is also addressed.

  1. Millimeter-wave Imaging Radiometer (MIR) data processing and development of water vapor retrieval algorithms

    NASA Technical Reports Server (NTRS)

    Chang, L. Aron

    1995-01-01

    This document describes the progress of the task of the Millimeter-wave Imaging Radiometer (MIR) data processing and the development of water vapor retrieval algorithms, for the second six-month performing period. Aircraft MIR data from two 1995 field experiments were collected and processed with a revised data processing software. Two revised versions of water vapor retrieval algorithm were developed, one for the execution of retrieval on a supercomputer platform, and one for using pressure as the vertical coordinate. Two implementations of incorporating products from other sensors into the water vapor retrieval system, one from the Special Sensor Microwave Imager (SSM/I), the other from the High-resolution Interferometer Sounder (HIS). Water vapor retrievals were performed for both airborne MIR data and spaceborne SSM/T-2 data, during field experiments of TOGA/COARE, CAMEX-1, and CAMEX-2. The climatology of water vapor during TOGA/COARE was examined by SSM/T-2 soundings and conventional rawinsonde.

  2. How are we addressing ligament balance in TKA? A literature review of revision etiology and technological advancement.

    PubMed

    Smith, Tyler; Elson, Leah; Anderson, Christopher; Leone, William

    2016-01-01

    Despite technological advances in operative technique and component materials, the total knee arthroplasty (TKA) revision burden, in the United States, has remained static for the past decade. In light of an anticipated exponential increase in annual surgical volume, it is important to thoroughly understand contemporary challenges associated with technologically driven TKA. This descriptive literature review harvested 69 relevant publications to extrapolate patient trends, benefits, costs, and complications associated with computer-assisted surgery, patient specific instrumentation, and intra-operative sensors. Due to additional charges, a steep learning curve, and questionable cost-effectiveness, widespread use of these systems has been limited. Intra-operative sensors are a relatively recent development, and have been shown to improve both soft-tissue balance and overall functional outcomes at a relatively low price and without disrupting operative workflow. The introduction of new technology into the operating suite should be considered carefully, especially with respect to combined clinically efficacy and cost.

  3. Confirming the Structural Validity of the My Class Inventory -- Short Form Revised

    ERIC Educational Resources Information Center

    Mariani, Melissa; Villares, Elizabeth; Sink, Christopher A.; Colvin, Kimberly; Kuba, Summer Perhay

    2015-01-01

    Researchers analyzed data collected from elementary school students (N = 893) to further establish the psychometric soundness of the My Class Inventory--Short Form Revised (MCI-SFR). A confirmatory factor analysis was conducted resulting in a good fit for a four-factor model, which corresponds to the instrument's four scales (Cohesion,…

  4. An Independent Investigation of the Validity of the School Attitude Assessment Survey-Revised

    ERIC Educational Resources Information Center

    Suldo, Shannon M.; Shaffer, Emily J.; Shaunessy, Elizabeth

    2008-01-01

    The psychometric properties of the School Attitude Assessment Survey-Revised (SAAS-R) are examined in a sample of 321 high school students. Students completed the SAAS-R along with measures of school climate, academic self-efficacy, and school satisfaction; school-related behaviors (i.e., attendance and discipline referrals) and academic…

  5. 76 FR 71977 - Update of the NICEATM-ICCVAM Five-Year Plan: Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-21

    ... testing and (2) research, development, translation, and validation of new and revised non-animal and other...-animal and other alternative assays for integration into Federal agency testing programs (ICCVAM, 2008... of areas of high priority for new and revised non-animal and alternative assays to reduce, refine...

  6. The Revised DCDQ: Is It a Suitable Screening Measure for Motor Difficulties in Adolescents?

    ERIC Educational Resources Information Center

    Pannekoek, Linda; Rigoli, Daniela; Piek, Jan P.; Barrett, Nicholas C.; Schoemaker, Marina

    2012-01-01

    The parent-rated Developmental Coordination Disorder Questionnaire (DCDQ) has been revised to incorporate a wider age range, including adolescence. In this exploratory study, internal consistency and validity of the DCDQ-2007 was assessed using a community-based sample of 87 adolescents. Psychometric properties of the DCDQ-2007 were investigated…

  7. Psychometric Properties of the Personality Diagnostic Questionnaire-Revised.

    ERIC Educational Resources Information Center

    Johnson, Jeffrey G.; Bornstein, Robert F.

    The validity of the Personality Diagnostic Questionnaire-Revised (PDQ-R) was examined. The PDQ-R and the Crowne-Marlowe Social Desirability Scale (SD) were administered in the spring of 1989 to 45 undergraduates (26 females and 19 males) at Gettysburg College in Pennsylvania. One month later, the Hopkins Symptom Check List (SCL-90) was…

  8. Revision of the new world species of Hylurgops LeConte, 1876 with the description of a new genus in the Hylastini (Coleoptera: Scolytinae) and comments on some Palearctic species

    Treesearch

    Javier E. Mercado-Velez; Jose F. Negron

    2014-01-01

    The New World species of the genus Hylurgops LeConte are revised and Hylurgops subcostulatus Mannerheim is transferred to the new genus Pachysquamus. A revised key to the tribe Hylastini which can be used for the world fauna is presented to include Pachysquamus. Our studies suggest that the Nearctic species H. knausi Swaine is a valid taxon, distinguishable from the...

  9. An Italian multicentre validation study of the coma recovery scale-revised.

    PubMed

    Estraneo, A; Moretta, P; De Tanti, A; Gatta, G; Giacino, J T; Trojano, L

    2015-10-01

    Rate of misdiagnosis of disorders of consciousness (DoC) can be reduced by employing validated clinical diagnostic tools, such as the Coma Recovery Scale-Revised (CRS-R). An Italian version of the CRS-R has been recently developed, but its applicability across different clinical settings, and its concurrent validity and diagnostic sensitivity have not been estimated yet. To perform a multicentre validation study of the Italian version of the Coma Recovery Scale-Revised (CRS-R). Analysis of inter-rater reliability, concurrent validity and diagnostic sensitivity of the scale. One Intensive Care Unit, 8 Post-acute rehabilitation centres and 2 Long-term facilities Twenty-seven professionals (physicians, N.=11; psychologists, N.=5; physiotherapists, N.=3; speech therapists, N.=6; nurses, N.=2) from 11 Italian Centres. CRS-R and Disability Rating Scale (DRS) applied to 122 patients with clinical diagnosis of Vegetative State (VS) or Minimally Conscious State (MCS). CRS-R has good-to-excellent inter-rater reliability for all subscales, particularly for the communication subscale. The Italian version of the CRS-R showed a high sensitivity and specificity in detecting MCS with reference to clinical consensus diagnosis. The CRS-R showed good concurrent validity with the Disability Rating Scale, which had very low specificity with reference to clinical consensus diagnosis. The Italian version of the CRS-R is a valid scale for use from the sub-acute to chronic stages of DoC. It can be administered reliably by all members of the rehabilitation team with different specialties, levels of experience and settings. The present study promote use of the Italian version of the CRS-R to improve diagnosis of DoC patients, and plan tailored rehabilitation treatment.

  10. Validation of a single summary score for the Prolapse/Incontinence Sexual Questionnaire-IUGA revised (PISQ-IR).

    PubMed

    Constantine, Melissa L; Pauls, Rachel N; Rogers, Rebecca R; Rockwood, Todd H

    2017-12-01

    The Prolapse/Incontinence Sexual Questionnaire-International Urogynecology Association (IUGA) Revised (PISQ-IR) measures sexual function in women with pelvic floor disorders (PFDs) yet is unwieldy, with six individual subscale scores for sexually active women and four for women who are not. We hypothesized that a valid and responsive summary score could be created for the PISQ-IR. Item response data from participating women who completed a revised version of the PISQ-IR at three clinical sites were used to generate item weights using a magnitude estimation (ME) and Q-sort (Q) approaches. Item weights were applied to data from the original PISQ-IR validation to generate summary scores. Correlation and factor analysis methods were used to evaluate validity and responsiveness of summary scores. Weighted and nonweighted summary scores for the sexually active PISQ-IR demonstrated good criterion validity with condition-specific measures: Incontinence Severity Index = 0.12, 0.11, 0.11; Pelvic Floor Distress Inventory-20 = 0.39, 0.39, 0.12; Epidemiology of Prolapse and Incontinence Questionnaire-Q35 = 0.26 0,.25, 0.40); Female Sexual Functioning Index subscale total score = 0.72, 0.75, 0.72 for nonweighted, ME, and Q summary scores, respectively. Responsiveness evaluation showed weighted and nonweighted summary scores detected moderate effect sizes (Cohen's d > 0.5). Weighted items for those NSA demonstrated significant floor effects and did not meet criterion validity. A PISQ-IR summary score for use with sexually active women, nonweighted or calculated with ME or Q item weights, is a valid and reliable measure for clinical use. The summary scores provide value for assesing clinical treatment of pelvic floor disorders.

  11. High-Temperature Strain Sensing for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Piazza, Anthony; Richards, Lance W.; Hudson, Larry D.

    2008-01-01

    Thermal protection systems (TPS) and hot structures are utilizing advanced materials that operate at temperatures that exceed abilities to measure structural performance. Robust strain sensors that operate accurately and reliably beyond 1800 F are needed but do not exist. These shortcomings hinder the ability to validate analysis and modeling techniques and hinders the ability to optimize structural designs. This presentation examines high-temperature strain sensing for aerospace applications and, more specifically, seeks to provide strain data for validating finite element models and thermal-structural analyses. Efforts have been made to develop sensor attachment techniques for relevant structural materials at the small test specimen level and to perform laboratory tests to characterize sensor and generate corrections to apply to indicated strains. Areas highlighted in this presentation include sensors, sensor attachment techniques, laboratory evaluation/characterization of strain measurement, and sensor use in large-scale structures.

  12. Development of a behaviour-based measurement tool with defined intervention level for assessing acute pain in cats.

    PubMed

    Calvo, G; Holden, E; Reid, J; Scott, E M; Firth, A; Bell, A; Robertson, S; Nolan, A M

    2014-12-01

    To develop a composite measure pain scale tool to assess acute pain in cats and derive an intervention score. To develop the prototype composite measure pain scale-feline, words describing painful cats were collected, grouped into behavioural categories and ranked. To assess prototype validity two observers independently assigned composite measure pain scale-feline and numerical rating scale scores to 25 hospitalised cats before and after analgesic treatment. Following interim analysis the prototype was revised (revised composite measure pain scale-feline). To determine intervention score, two observers independently assigned revised composite measure pain scale-feline and numerical rating scale scores to 116 cats. A further observer, a veterinarian, stated whether analgesia was necessary. Mean ± sd decrease in revised composite measure pain scale-feline and numerical rating scale scores following analgesia were 2 · 4 ± 2 · 87 and 1 · 9 ± 2 · 34, respectively (95% confidence interval for mean change in revised composite measure pain scale-feline between 1 · 21 and 3 · 6). Changes in revised composite measure pain scale-feline and numerical rating scale were significantly correlated (r = 0 · 8) (P < 0001). Intervention level score of ≥4/16 was derived for revised composite measure pain scale-feline (26 · 7% misclassification) and ≥3/10 for numerical rating scale (14 · 5% misclassification). A valid instrument with a recommended analgesic intervention level has been developed to assess acute clinical pain in cats that should be readily applicable in practice. © 2014 British Small Animal Veterinary Association.

  13. Students' Initial Knowledge State and Test Design: Towards a Valid and Reliable Test Instrument

    ERIC Educational Resources Information Center

    CoPo, Antonio Roland I.

    2015-01-01

    Designing a good test instrument involves specifications, test construction, validation, try-out, analysis and revision. The initial knowledge state of forty (40) tertiary students enrolled in Business Statistics course was determined and the same test instrument undergoes validation. The designed test instrument did not only reveal the baseline…

  14. A Brazilian Portuguese version of the Revised Fibromyalgia Impact Questionnaire (FIQR): a validation study.

    PubMed

    Paiva, Eduardo S; Heymann, Roberto E; Rezende, Marcelo C; Helfenstein, Milton; Martinez, Jose Eduardo; Provenza, Jose Roberto; Ranzolin, Aline; de Assis, Marcos Renato; Pasqualin, Vivian D; Bennett, Robert M

    2013-08-01

    The Fibromyalgia Impact Questionnaire (FIQ) was specifically developed to assess disease severity and functional ability in fibromyalgia patients. In 2009, a revised version of the FIQ was published, the FIQR; this version achieved a better balance among different domains (function, overall impact, symptoms). Here, we present the validity and reliability of the Brazilian version of the Revised Fibromyalgia Impact Questionnaire (FIQR). Female fibromyalgia patients (n = 106) completed an online survey consisting of the Short Form 36 (SF-36) questionnaire, the original FIQ, and the Brazilian Portuguese FIQR, which was translated by a standard method. Validity was established with correlational analyses between the FIQR, FIQ, and SF-36 items. Three domains were established for the FIQR (function, overall impact, symptoms), and their contribution for the SF-36 subscales was also scrutinized. The Brazilian FIQR validation process showed that the questions performed in a very similar way to the original English FIQR. The new questions in the FIQR symptoms domain (memory, balance, tenderness, and environmental sensitivity) revealed a significant impact in fibromyalgia (FM) patients. The Brazilian Portuguese FIQR demonstrated excellent reliability, with a Cronbach's alpha of 0.96. There was a gain on weight of the function domain and a decrease of the symptom domain, leading to a better balance among domains. The FIQR predicted a great number of SF-36 subscales, showing good convergent validity. The Brazilian Portuguese version of the FIQR was validated and found to be a reliable, easy-to-use, and score FM-specific questionnaire that should prove useful in routine clinical practice and FM-related research.

  15. The discriminant (and convergent) validity of the Personality Inventory for DSM-5.

    PubMed

    Crego, Cristina; Gore, Whitney L; Rojas, Stephanie L; Widiger, Thomas A

    2015-10-01

    A considerable body of research has rapidly accumulated with respect to the validity of the Diagnostic and Statistical Manual of Mental Disorders (5th ed.; DSM-5) dimensional trait model as it is assessed by the Personality Inventory for Diagnostic and Statistical Manual of Mental Disorders (PID-5; Krueger et al., 2012). This research though has not focused specifically on discriminant validity, although allusions to potentially problematic discriminant validity have been raised. The current study addressed discriminant validity, reporting for the first time the correlations among the PID-5 domain scales. Also reported are the bivariate correlations of the 25 PID-5 maladaptive trait scales with the personality domain scales of the NEO Personality Inventory-Revised (Costa & McCrae, 1992), the International Personality Item Pool-NEO (Goldberg et al., 2006), the Inventory of Personal Characteristics (Almagor et al., 1995), the 5-Dimensional Personality Test (van Kampen, 2012), and the HEXACO Personality Inventory-Revised (Lee & Ashton, 2004). The results are discussed with respect to the implications of and alternative explanations for potentially problematic discriminant validity. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  16. Intrusion-aware alert validation algorithm for cooperative distributed intrusion detection schemes of wireless sensor networks.

    PubMed

    Shaikh, Riaz Ahmed; Jameel, Hassan; d'Auriol, Brian J; Lee, Heejo; Lee, Sungyoung; Song, Young-Jae

    2009-01-01

    Existing anomaly and intrusion detection schemes of wireless sensor networks have mainly focused on the detection of intrusions. Once the intrusion is detected, an alerts or claims will be generated. However, any unidentified malicious nodes in the network could send faulty anomaly and intrusion claims about the legitimate nodes to the other nodes. Verifying the validity of such claims is a critical and challenging issue that is not considered in the existing cooperative-based distributed anomaly and intrusion detection schemes of wireless sensor networks. In this paper, we propose a validation algorithm that addresses this problem. This algorithm utilizes the concept of intrusion-aware reliability that helps to provide adequate reliability at a modest communication cost. In this paper, we also provide a security resiliency analysis of the proposed intrusion-aware alert validation algorithm.

  17. Intrusion-Aware Alert Validation Algorithm for Cooperative Distributed Intrusion Detection Schemes of Wireless Sensor Networks

    PubMed Central

    Shaikh, Riaz Ahmed; Jameel, Hassan; d’Auriol, Brian J.; Lee, Heejo; Lee, Sungyoung; Song, Young-Jae

    2009-01-01

    Existing anomaly and intrusion detection schemes of wireless sensor networks have mainly focused on the detection of intrusions. Once the intrusion is detected, an alerts or claims will be generated. However, any unidentified malicious nodes in the network could send faulty anomaly and intrusion claims about the legitimate nodes to the other nodes. Verifying the validity of such claims is a critical and challenging issue that is not considered in the existing cooperative-based distributed anomaly and intrusion detection schemes of wireless sensor networks. In this paper, we propose a validation algorithm that addresses this problem. This algorithm utilizes the concept of intrusion-aware reliability that helps to provide adequate reliability at a modest communication cost. In this paper, we also provide a security resiliency analysis of the proposed intrusion-aware alert validation algorithm. PMID:22454568

  18. Measuring Patient Mobility in the ICU Using a Novel Noninvasive Sensor

    PubMed Central

    Ma, Andy J.; Rawat, Nishi; Reiter, Austin; Shrock, Christine; Zhan, Andong; Stone, Alex; Rabiee, Anahita; Griffin, Stephanie; Needham, Dale M.; Saria, Suchi

    2017-01-01

    Objectives To develop and validate a noninvasive mobility sensor to automatically and continuously detect and measure patient mobility in the ICU. Design Prospective, observational study. Setting Surgical ICU at an academic hospital. Patients Three hundred sixty-two hours of sensor color and depth image data were recorded and curated into 109 segments, each containing 1,000 images, from eight patients. Interventions None. Measurements and Main Results Three Microsoft Kinect sensors (Microsoft, Beijing, China) were deployed in one ICU room to collect continuous patient mobility data. We developed software that automatically analyzes the sensor data to measure mobility and assign the highest level within a time period. To characterize the highest mobility level, a validated 11-point mobility scale was collapsed into four categories: nothing in bed, in-bed activity, out-of-bed activity, and walking. Of the 109 sensor segments, the noninvasive mobility sensor was developed using 26 of these from three ICU patients and validated on 83 remaining segments from five different patients. Three physicians annotated each segment for the highest mobility level. The weighted Kappa (κ) statistic for agreement between automated noninvasive mobility sensor output versus manual physician annotation was 0.86 (95% CI, 0.72–1.00). Disagreement primarily occurred in the “nothing in bed” versus “in-bed activity” categories because “the sensor assessed movement continuously,” which was significantly more sensitive to motion than physician annotations using a discrete manual scale. Conclusions Noninvasive mobility sensor is a novel and feasible method for automating evaluation of ICU patient mobility. PMID:28291092

  19. Sensor System Performance Evaluation and Benefits from the NPOESS Airborne Sounder Testbed-Interferometer (NAST-I)

    NASA Technical Reports Server (NTRS)

    Larar, A.; Zhou, D.; Smith, W.

    2009-01-01

    Advanced satellite sensors are tasked with improving global-scale measurements of the Earth's atmosphere, clouds, and surface to enable enhancements in weather prediction, climate monitoring, and environmental change detection. Validation of the entire measurement system is crucial to achieving this goal and thus maximizing research and operational utility of resultant data. Field campaigns employing satellite under-flights with well-calibrated FTS sensors aboard high-altitude aircraft are an essential part of this validation task. The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed-Interferometer (NAST-I) has been a fundamental contributor in this area by providing coincident high spectral/spatial resolution observations of infrared spectral radiances along with independently-retrieved geophysical products for comparison with like products from satellite sensors being validated. This paper focuses on some of the challenges associated with validating advanced atmospheric sounders and the benefits obtained from employing airborne interferometers such as the NAST-I. Select results from underflights of the Aqua Atmospheric InfraRed Sounder (AIRS) and the Infrared Atmospheric Sounding Interferometer (IASI) obtained during recent field campaigns will be presented.

  20. Development and Validation of a New Near-Infrared Sensor to Measure Polyethylene Glycol (PEG) Concentration in Water.

    PubMed

    Buzzi, Olivier; Yuan, Shengyang; Routley, Benjamin

    2017-06-10

    A near-infrared absorption based laser sensor has been designed and validated for the real-time measurement of polyethylene glycol (PEG) concentration. The wavelength was selected after the determination of the absorption spectrum of deionised water and PEG solutions using a Varian Cary 6000i spectrophotometer, in order to limit the influence of PEG molecular mass on the absorption measurement. With this new sensor, the water is treated as the attenuating species and the addition of PEG in water reduces the absorbance of the medium. The concept was validated using three different PEG types (PEG 6,000, 20,000, and 35,000) and it was found that the results follow Beer Lambert's law. The influence of temperature was assessed by testing the PEG 20,000 at four different temperatures that could be encountered in a laboratory environment. The data show a slight temperature influence (increase of absorbance by 8% when the temperature rises from about 20 to about 29 degrees). Following the validation phase conducted ex situ, a prototype of an immersible sensor was built and calibrated for in situ measurements.

  1. 8th GCC: consolidated feedback to US FDA on the 2013 draft FDA guidance on bioanalytical method validation.

    PubMed

    Bower, Joseph; Fast, Douglas; Garofolo, Fabio; Gouty, Dominique; Hayes, Roger; Lowes, Steve; Nicholson, Robert; LeLacheur, Richard; Bravo, Jennifer; Shoup, Ronald; Dumont, Isabelle; Carbone, Mary; Zimmer, Jennifer; Ortuno, Jordi; Caturla, Maria Cruz; Datin, Jim; Lansing, Tim; Fatmi, Saadya; Struwe, Petra; Sheldon, Curtis; Islam, Rafiqul; Yu, Mathilde; Hulse, Jim; Kamerud, John; Lin, John; Doughty, John; Kurylak, Kai; Tang, Daniel; Buonarati, Mike; Blanchette, Alexandre; Levesque, Ann; Gagnon-Carignan, Sofi; Lin, Jenny; Ray, Gene; Liu, Yanseng; Khan, Masood; Xu, Allan; El-Sulayman, Gibran; DiMarco, Chantal; Bouhajib, Mohammed; Tacey, Dick; Jenkins, Rand; der Strate, Barry van; Briscoe, Chad; Karnik, Shane; Rhyne, Paul; Garofolo, Wei; Schultz, Gary; Roberts, Andrew; Redrup, Mike; DuBey, Ira; Conliffe, Phyllis; Pekol, Teri; Hantash, Jamil; Cojocaru, Laura; Allen, Mike; Reuschel, Scott; Watson, Andrea; Farrell, Colin; Groeber, Elizabeth; Malone, Michele; Nowatzke, William; Fang, Xinping

    2014-01-01

    The 8th GCC Closed Forum for Bioanalysis was held in Baltimore, MD, USA on 5 December 2013, immediately following the 2013 AAPS Workshop (Crystal City V): Quantitative Bioanalytical Methods Validation and Implementation--The 2013 Revised FDA Guidance. This GCC meeting was organized to discuss the contents of the draft revised FDA Guidance on bioanalytical method validation that was published in September 2013 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants, from seven countries, representing 46 bioanalytical CRO companies/sites. This event represented a unique opportunity for CRO bioanalytical experts to share their opinions and concerns regarding the draft FDA Guidance, and to build unified comments to be provided to the FDA.

  2. Clinical Validity of the ADI-R in a US-Based Latino Population

    ERIC Educational Resources Information Center

    Vanegas, Sandra B.; Magaña, Sandra; Morales, Miguel; McNamara, Ellyn

    2016-01-01

    The Autism Diagnostic Interview-Revised (ADI-R) has been validated as a tool to aid in the diagnosis of Autism; however, given the growing diversity in the United States, the ADI-R must be validated for different languages and cultures. This study evaluates the validity of the ADI-R in a US-based Latino, Spanish-speaking population of 50 children…

  3. Continued Development of Compact Multi-gas Monitor for Life Support Systems Control in Space

    NASA Technical Reports Server (NTRS)

    Delgado-Alonso, Jesús; Phillips, Straun; Chullen, Cinda; Quinn, Gregory

    2016-01-01

    Miniature optic gas sensors (MOGS) based on luminescent materials have shown great potential as alternatives to Near-Infrared-based gas sensor systems for the advanced space suit portable life support system (PLSS). The unique capability of MOGS for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of MOGS humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages of MOGS over both traditional and advanced Non-Dispersive Infrared (NDIR) gas sensors, which have shown so far longer life than luminescent sensors. This paper presents the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted at Intelligent Optical Systems laboratories, a United Technology Corporation Aerospace Systems (UTAS) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems and the advantages and limitations found through detailed sensor validation are discussed.

  4. Generic Helicopter-Based Testbed for Surface Terrain Imaging Sensors

    NASA Technical Reports Server (NTRS)

    Alexander, James; Goldberg, Hannah; Montgomery, James; Spiers, Gary; Liebe, Carl; Johnson, Andrew; Gromov, Konstantin; Konefat, Edward; Lam, Raymond; Meras, Patrick

    2008-01-01

    To be certain that a candidate sensor system will perform as expected during missions, we have developed a field test system and have executed test flights with a helicopter-mounted sensor platform over desert terrains, which simulate Lunar features. A key advantage to this approach is that different sensors can be tested and characterized in an environment relevant to the flight needs prior to flight. Testing the various sensors required the development of a field test system, including an instrument to validate the truth of the sensor system under test. The field test system was designed to be flexible enough to cover the test needs of many sensors (lidar, radar, cameras) that require an aerial test platform, including helicopters, airplanes, unmanned aerial vehicles (UAV), or balloons. To validate the performance of the sensor under test, the dynamics of the test platform must be known with sufficient accuracy to provide accurate models for input into algorithm development. The test system provides support equipment to measure the dynamics of the field test sensor platform, and allow computation of the truth position, velocity, attitude, and time.

  5. Continued Development of Compact Multi-Gas Monitor for Life Support Systems Control in Space

    NASA Technical Reports Server (NTRS)

    Delgado, Jesus; Phillips, Straun; Chullen, Cinda

    2015-01-01

    Miniature optic gas sensors (MOGS) based on luminescent materials have shown great potential as alternatives to NIR-based gas sensor systems for the Portable Life Support System (PLSS). The unique capability of MOGS for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of MOGS humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages of MOGS over both traditional and advanced Non-Dispersive Infrared (NDIR) gas sensors, which have shown so far longer life than luminescent sensors. In this paper we present the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted at Intelligent Optical Systems laboratories, a United Technology Corporation Aerospace Systems (UTAS) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems and the advantages and limitations found through detailed sensor validation are discussed.

  6. Measuring chronic condition self-management in an Australian community: factor structure of the revised Partners in Health (PIH) scale.

    PubMed

    Smith, David; Harvey, Peter; Lawn, Sharon; Harris, Melanie; Battersby, Malcolm

    2017-01-01

    To evaluate the factor structure of the revised Partners in Health (PIH) scale for measuring chronic condition self-management in a representative sample from the Australian community. A series of consultations between clinical groups underpinned the revision of the PIH. The factors in the revised instrument were proposed to be: knowledge of illness and treatment, patient-health professional partnership, recognition and management of symptoms and coping with chronic illness. Participants (N = 904) reporting having a chronic illness completed the revised 12-item scale. Two a priori models, the 4-factor and bi-factor models were then evaluated using Bayesian confirmatory factor analysis (BCFA). Final model selection was established on model complexity, posterior predictive p values and deviance information criterion. Both 4-factor and bi-factor BCFA models with small informative priors for cross-loadings provided an acceptable fit with the data. The 4-factor model was shown to provide a better and more parsimonious fit with the observed data in terms of substantive theory. McDonald's omega coefficients indicated that the reliability of subscale raw scores was mostly in the acceptable range. The findings showed that the PIH scale is a relevant and structurally valid instrument for measuring chronic condition self-management in an Australian community. The PIH scale may help health professionals to introduce the concept of self-management to their patients and provide assessment of areas of self-management. A limitation is the narrow range of validated PIH measurement properties to date. Further research is needed to evaluate other important properties such as test-retest reliability, responsiveness over time and content validity.

  7. Development of a tool to assess adherence to a model of the division of responsibility in feeding young children: using response mapping to capacitate validation measures.

    PubMed

    Lohse, Barbara; Satter, Ellyn; Arnold, Kristen

    2014-04-01

    Accurate early assessment and targeted intervention with problematic parent/child feeding dynamics is critical for the prevention and treatment of child obesity. The division of responsibility in feeding (sDOR), articulated by the Satter Feeding Dynamics Model (fdSatter), has been demonstrated clinically as an effective approach to reduce child feeding problems, including those leading to obesity. Lack of a tested instrument to examine adherence to fdSatter stimulated initial construction of the Satter Feeding Dynamics Inventory (fdSI). The aim of this project was to refine the item pool to establish translational validity, making the fdSI suitable for advanced psychometric analysis. Cognitive interviews (n = 80) with caregivers of varied socioeconomic strata informed revisions that demonstrated face and content validity. fdSI responses were mapped to interviews using an iterative, multi-phase thematic approach to provide an instrument ready for construct validation. fdSI development required five interview phases over 32 months: Foundational; Refinement; Transitional; Assurance; and Launching. Each phase was associated with item reduction and revision. Thirteen items were removed from the 38-item Foundational phase and seven were revised in the Refinement phase. Revisions, deletions, and additions prompted by Transitional and Assurance phase interviews resulted in the 15-item Launching phase fdSI. Only one Foundational phase item was carried through all development phases, emphasizing the need to test for item comprehension and interpretation before psychometric analyses. Psychometric studies of item pools without encrypted meanings will facilitate progress toward a tool that accurately detects adherence to sDOR. Ability to measure sDOR will facilitate focus on feeding behaviors associated with reduced risk of childhood obesity.

  8. Validity and Reliability of a Wearable Inertial Sensor to Measure Velocity and Power in the Back Squat and Bench Press.

    PubMed

    Orange, Samuel T; Metcalfe, James W; Liefeith, Andreas; Marshall, Phil; Madden, Leigh A; Fewster, Connor R; Vince, Rebecca V

    2018-05-08

    Orange, ST, Metcalfe, JW, Liefeith, A, Marshall, P, Madden, LA, Fewster, CR, and Vince, RV. Validity and reliability of a wearable inertial sensor to measure velocity and power in the back squat and bench press. J Strength Cond Res XX(X): 000-000, 2018-This study examined the validity and reliability of a wearable inertial sensor to measure velocity and power in the free-weight back squat and bench press. Twenty-nine youth rugby league players (18 ± 1 years) completed 2 test-retest sessions for the back squat followed by 2 test-retest sessions for the bench press. Repetitions were performed at 20, 40, 60, 80, and 90% of 1 repetition maximum (1RM) with mean velocity, peak velocity, mean power (MP), and peak power (PP) simultaneously measured using an inertial sensor (PUSH) and a linear position transducer (GymAware PowerTool). The PUSH demonstrated good validity (Pearson's product-moment correlation coefficient [r]) and reliability (intraclass correlation coefficient [ICC]) only for measurements of MP (r = 0.91; ICC = 0.83) and PP (r = 0.90; ICC = 0.80) at 20% of 1RM in the back squat. However, it may be more appropriate for athletes to jump off the ground with this load to optimize power output. Further research should therefore evaluate the usability of inertial sensors in the jump squat exercise. In the bench press, good validity and reliability were evident only for the measurement of MP at 40% of 1RM (r = 0.89; ICC = 0.83). The PUSH was unable to provide a valid and reliable estimate of any other criterion variable in either exercise. Practitioners must be cognizant of the measurement error when using inertial sensor technology to quantify velocity and power during resistance training, particularly with loads other than 20% of 1RM in the back squat and 40% of 1RM in the bench press.

  9. A Factor Analysis of The Social Interest Index--Revised.

    ERIC Educational Resources Information Center

    Zarski, John J.; And Others

    1983-01-01

    Factor analyzed the Social Interest Index-Revised (SII-R), which measures levels of social interest attained in each of four life task areas. Four factors (N=308) were defined, i.e., a self-significance factor, a love factor, a friendship factor, and a work factor. Results support the empirical validity of the scale. (Author/PAS)

  10. Examining the Construct Validity of the Psychopathic Personality Inventory-Revised: Preferential Correlates of Fearless Dominance and Self-Centered Impulsivity

    ERIC Educational Resources Information Center

    Edens, John F.; McDermott, Barbara E.

    2010-01-01

    Although the construct of psychopathy is frequently construed as a unitary syndrome, the Psychopathic Personality Inventory (PPI; Lilienfeld & Andrews, 1996) and its revision, the PPI-R (Lilienfeld & Widows, 2005), are composed of 2 scales, termed Fearless Dominance (FD) and Self-Centered Impulsivity (SCI), which appear to reflect orthogonal…

  11. The Attitudes & Beliefs on Classroom Control Inventory-Revised and Revisited: A Continuation of Construct Validation

    ERIC Educational Resources Information Center

    Martin, Nancy K.; Yin, Zenong; Mayall, Hayley

    2008-01-01

    The purpose of this study was to report the psychometric properties of the revised Attitudes and Beliefs of Classroom Control Inventory (ABCC-R). Data were collected from 489 participants via the ABCC-R, Teacher Efficacy Scale, Problems in School Questionnaire, and a demographic questionnaire. Results were in keeping with the construct. The…

  12. Updated Design Standards and Guidance from the What Works Clearinghouse: Regression Discontinuity Designs and Cluster Designs

    ERIC Educational Resources Information Center

    Cole, Russell; Deke, John; Seftor, Neil

    2016-01-01

    The What Works Clearinghouse (WWC) maintains design standards to identify rigorous, internally valid education research. As education researchers advance new methodologies, the WWC must revise its standards to include an assessment of the new designs. Recently, the WWC has revised standards for two emerging study designs: regression discontinuity…

  13. Validating the Repetitive Behavior Scale-Revised in Young Children with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Mirenda, Pat; Smith, Isabel M.; Vaillancourt, Tracy; Georgiades, Stelios; Duku, Eric; Szatmari, Peter; Bryson, Susan; Fombonne, Eric; Roberts, Wendy; Volden, Joanne; Waddell, Charlotte; Zwaigenbaum, Lonnie

    2010-01-01

    This study examined the factor structure of the Repetitive Behavior Scale-Revised (RBS-R) in a sample of 287 preschool-aged children with autism spectrum disorder (ASD). A confirmatory factor analysis was used to examine six competing structural models. Spearman's rank order correlations were calculated to examine the associations between factor…

  14. Measuring Change in Career Counseling: Validation of the "Career Futures Inventory-Revised"

    ERIC Educational Resources Information Center

    Rottinghaus, Patrick J.; Eshelman, Alec; Gore, Jonathan S.; Keller, Kari J.; Schneider, Madalyn; Harris, Kristine L.

    2017-01-01

    This retrospective chart review study examined the factor structure of the "Career Futures Inventory-Revised" (CFI-R; Rottinghaus et al. in "J Career Assess" 20:123-139, 2012) and its utility as a career counseling outcome measure using a sample of 332 clients from a university career center. The CFI-R examines career agency…

  15. Validation of the Early Childhood Ecology Scale-Revised: A Reflective Tool for Teacher Candidates

    ERIC Educational Resources Information Center

    Flores, Belinda Bustos; Casebeer, Cindy M.; Riojas-Cortez, Mari

    2011-01-01

    Given increasing numbers of young culturally and/or linguistically diverse (CLD) children across the United States, it is crucial to prepare early childhood teachers to create high-quality environments that facilitate the development of all children. The Early Childhood Ecology Scale-Revised (ECES-R) has been developed as a reflective tool to help…

  16. Two Revised Measures of Coping for Individuals with Late-Deafness

    ERIC Educational Resources Information Center

    Meyer, Jill M.; Kashubeck-West, Susan; Portela, Lindsay

    2018-01-01

    Purpose: The present study had two goals: (a) to examine the revised structures of these measures to determine the reliability and validity when used in a sample of individuals with latedeafness, and (b) to examine differences in coping style in individuals with late-deafness across race, ethnicity, gender, age, socioeconomic status (SES), level…

  17. Revising the Child and Adolescent Perfectionism Scale: A Test of the Four-Factor Structure in a Chinese Sample

    ERIC Educational Resources Information Center

    Yang, Hongfei; Hong, Chaoqin; Tao, Xiaodan; Zhu, Lingyi

    2015-01-01

    This study examined the structure, reliability, and validity of the revised Chinese version of the Child and Adolescent Perfectionism Scale (N = 933). The results confirmed the four-factor structure of the Chinese version of the Child and Adolescent Perfectionism Scale. Implications, limitations, and suggestions for future research are provided.

  18. Unexpected but Most Welcome: Mixed Methods for the Validation and Revision of the Participatory Evaluation Measurement Instrument

    ERIC Educational Resources Information Center

    Daigneault, Pierre-Marc; Jacob, Steve

    2014-01-01

    Although combining methods is nothing new, more contributions about why and how to mix methods for validation purposes are needed. This article presents a case of validating the inferences drawn from the Participatory Evaluation Measurement Instrument, an instrument that purports to measure stakeholder participation in evaluation. Although the…

  19. Validity of the Revised Children's Anxiety and Depression Scale for Youth with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Sterling, Lindsey; Renno, Patricia; Storch, Eric A.; Ehrenreich-May, Jill; Lewin, Adam B.; Arnold, Elysse; Lin, Enjey; Wood, Jeffrey

    2015-01-01

    High rates of anxiety and depression are reported among youth with autism spectrum disorders. These conditions are generally assessed using measures validated for typically developing youth. Few studies have investigated their validity for autism spectrum disorders, which is crucial for accurate assessment and the provision of proper treatment.…

  20. Intelligent Sensors for Integrated Systems Health Management (ISHM)

    NASA Technical Reports Server (NTRS)

    Schmalzel, John L.

    2008-01-01

    IEEE 1451 Smart Sensors contribute to a number of ISHM goals including cost reduction achieved through: a) Improved configuration management (TEDS); and b) Plug-and-play re-configuration. Intelligent Sensors are adaptation of Smart Sensors to include ISHM algorithms; this offers further benefits: a) Sensor validation. b) Confidence assessment of measurement, and c) Distributed ISHM processing. Space-qualified intelligent sensors are possible a) Size, mass, power constraints. b) Bus structure/protocol.

  1. Wearable vital parameters monitoring system

    NASA Astrophysics Data System (ADS)

    Caramaliu, Radu Vadim; Vasile, Alexandru; Bacis, Irina

    2015-02-01

    The system we propose monitors body temperature, heart rate and beside this, it tracks if the person who wears it suffers a faint. It uses a digital temperature sensor, a pulse sensor and a gravitational acceleration sensor to monitor the eventual faint or small heights free falls. The system continuously tracks the GPS position when available and stores the last valid data. So, when measuring abnormal vital parameters the module will send an SMS, using the GSM cellular network , with the person's social security number, the last valid GPS position for that person, the heart rate, the body temperature and, where applicable, a valid fall alert or non-valid fall alert. Even though such systems exist, they contain only faint detection or heart rate detection. Usually there is a strong correlation between low/high heart rate and an eventual faint. Combining both features into one system results in a more reliable detection device.

  2. Development of Life Prediction Capabilities for Liquid Propellant Rocket Engines. Task 3. Sensor Data Validation and Reconstruction. Phase 1. System Architecture Study

    DTIC Science & Technology

    1991-06-01

    Validation And Reconstruction -~ Phase 1: System Architecture Study i ".- Contract NAS 3 -25883 I - _ CR-187124 -4 Phase I Final Report,, " , I Prepared for...131 NAS 3 -25883 1.0 INTRODUCTION 1 2.0 EXECUTIVE SUMMARY 2 3.0 TECHNICAL DISCUSSION 8 3.1 Review of SSME Test Data and Validation Procedure 8 3.1.1...NAS 3 -25883 FIGURES FigureNo. e 1 Elements The Sensor Data Validation and Signal Reconstuction System 7 3 Current NASA MSFC Data Review Process 12 4

  3. Validation of a new micro-manometer pressure sensor for cardiovascular measurements in mice.

    PubMed

    Trevino, Rodolfo J; Jones, Douglas L; Escobedo, Daniel; Porterfield, John; Larson, Erik; Chisholm, Gary B; Barton, Amanda; Feldman, Marc D

    2010-01-01

    Abstract The Scisense (London, ON, Canada) micro-manometer pressure sensor is currently being used by investigators to evaluate cardiovascular physiology in mice, but has not been validated to date. The purpose of the current study is to compare the 1.2 F Scisense pressure sensor to the current gold standard produced by Millar Instruments (Houston, TX) (1.4 F). In vitro comparisons were preformed including temperature drift, frequency response analysis up to 250 Hz, and damping coefficient and natural frequency determined via a pop test. The authors also performed in vivo comparisons including pressure drift, dose-response studies to IV isoproterenol, maximum adrenergic stimulation with IV dobutamine, and simultaneous placement of both micro-manometer pressure sensors in the same intact murine hearts. The authors conclude that both sensors are equivalent, and that the Scisense pressure sensor represents an alternative to the current gold standard, the Millar micro-manometer pressure sensor for in vivo pressure measurements in the mouse.

  4. Error analysis in a stereo vision-based pedestrian detection sensor for collision avoidance applications.

    PubMed

    Llorca, David F; Sotelo, Miguel A; Parra, Ignacio; Ocaña, Manuel; Bergasa, Luis M

    2010-01-01

    This paper presents an analytical study of the depth estimation error of a stereo vision-based pedestrian detection sensor for automotive applications such as pedestrian collision avoidance and/or mitigation. The sensor comprises two synchronized and calibrated low-cost cameras. Pedestrians are detected by combining a 3D clustering method with Support Vector Machine-based (SVM) classification. The influence of the sensor parameters in the stereo quantization errors is analyzed in detail providing a point of reference for choosing the sensor setup according to the application requirements. The sensor is then validated in real experiments. Collision avoidance maneuvers by steering are carried out by manual driving. A real time kinematic differential global positioning system (RTK-DGPS) is used to provide ground truth data corresponding to both the pedestrian and the host vehicle locations. The performed field test provided encouraging results and proved the validity of the proposed sensor for being used in the automotive sector towards applications such as autonomous pedestrian collision avoidance.

  5. Error Analysis in a Stereo Vision-Based Pedestrian Detection Sensor for Collision Avoidance Applications

    PubMed Central

    Llorca, David F.; Sotelo, Miguel A.; Parra, Ignacio; Ocaña, Manuel; Bergasa, Luis M.

    2010-01-01

    This paper presents an analytical study of the depth estimation error of a stereo vision-based pedestrian detection sensor for automotive applications such as pedestrian collision avoidance and/or mitigation. The sensor comprises two synchronized and calibrated low-cost cameras. Pedestrians are detected by combining a 3D clustering method with Support Vector Machine-based (SVM) classification. The influence of the sensor parameters in the stereo quantization errors is analyzed in detail providing a point of reference for choosing the sensor setup according to the application requirements. The sensor is then validated in real experiments. Collision avoidance maneuvers by steering are carried out by manual driving. A real time kinematic differential global positioning system (RTK-DGPS) is used to provide ground truth data corresponding to both the pedestrian and the host vehicle locations. The performed field test provided encouraging results and proved the validity of the proposed sensor for being used in the automotive sector towards applications such as autonomous pedestrian collision avoidance. PMID:22319323

  6. Satellite stratospheric aerosol measurement validation

    NASA Technical Reports Server (NTRS)

    Russell, P. B.; Mccormick, M. P.

    1984-01-01

    The validity of the stratospheric aerosol measurements made by the satellite sensors SAM II and SAGE was tested by comparing their results with each other and with results obtained by other techniques (lider, dustsonde, filter, and impactor). The latter type of comparison required the development of special techniques that convert the quantity measured by the correlative sensor (e.g. particle backscatter, number, or mass) to that measured by the satellite sensor (extinction) and quantitatively estimate the uncertainty in the conversion process. The results of both types of comparisons show agreement within the measurement and conversion uncertainties. Moreover, the satellite uncertainty is small compared to aerosol natural variability (caused by seasonal changes, volcanoes, sudden warmings, and vortex structure). It was concluded that the satellite measurements are valid.

  7. Demand effects on positive response distortion by police officer applicants on the Revised NEO Personality Inventory.

    PubMed

    Detrick, Paul; Chibnall, John T; Call, Cynthia

    2010-09-01

    Understanding and detecting response distortion is important in the high-demand circumstances of personnel selection. In this article, we describe positive response distortion on the Revised NEO Personality Inventory (NEO PI-R; Costa & McCrae, 1992) among police officer applicants under high and low demand conditions. Positive response distortion primarily reflected denial/minimization of Neuroticism and accentuation of traits associated with moralistic bias (Agreeableness and Conscientiousness). Validity of the NEO PI-R research validity scale, Positive Presentation Management, was weakly supported with respect to the Neuroticism domain only. Results will be useful in interpreting personality inventory results in the police personnel selection process.

  8. Validation of the Abdominal Pain Index using a revised scoring method.

    PubMed

    Laird, Kelsey T; Sherman, Amanda L; Smith, Craig A; Walker, Lynn S

    2015-06-01

    Evaluate the psychometric properties of child- and parent-report versions of the four-item Abdominal Pain Index (API) in children with functional abdominal pain (FAP) and healthy controls, using a revised scoring method that facilitates comparisons of scores across samples and time. Pediatric patients aged 8-18 years with FAP and controls completed the API at baseline (N = 1,967); a subset of their parents (N = 290) completed the API regarding the child's pain. Subsets of patients completed follow-up assessments at 2 weeks (N = 231), 3 months (N = 330), and 6 months (N = 107). Subsets of both patients (N = 389) and healthy controls (N = 172) completed a long-term follow-up assessment (mean age at follow-up = 20.21 years, SD = 3.75). The API demonstrated good concurrent, discriminant, and construct validity, as well as good internal consistency. We conclude that the API, using the revised scoring method, is a useful, reliable, and valid measure of abdominal pain severity. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Validation of Student and Parent Reported Data on the Basic Grant Application Form: Pre-Award Validation Analysis Study. Revised Final Report.

    ERIC Educational Resources Information Center

    Applied Management Sciences, Inc., Silver Spring, MD.

    The 1978-1979 pre-award institution validation process for the Basic Educational Opportunity Grant (BEOG) program was studied, based on applicant and grant recipient files as of the end of February 1979. The objective was to assess the impact of the validation process on the proper award of BEOGs, and to determine whether the criteria for…

  10. Cross-cultural validation of the revised temperament and character inventory in the Bulgarian language.

    PubMed

    Tilov, Boris; Dimitrova, Donka; Stoykova, Maria; Tornjova, Bianka; Foreva, Gergana; Stoyanov, Drozdstoj

    2012-12-01

    Health-care professions have long been considered prone to work-related stress, yet recent research in Bulgaria indicates alarmingly high levels of burnout. Cloninger's inventory is used to analyse and evaluate correlation between personality characteristics and degree of burnout syndrome manifestation among the risk categories of health-care professionals. The primary goal of this study was to test the conceptual validity and cross-cultural applicability of the revised TCI (TCI-R), developed in the United States, in a culturally, socially and economically diverse setting. Linguistic validation, test-retest studies, statistical and expert analyses were performed to assess cross-cultural applicability of the revised Cloninger's temperament and character inventory in Bulgarian, its reliability and internal consistency and construct validity. The overall internal consistency of TCI-R and its scales as well as the interscale and test-retest correlations prove that the translated version of the questionnaire is acceptable and cross-culturally applicable for the purposes of studying organizational stress and burnout risk in health-care professionals. In general the cross-cultural adaptation process, even if carried out in a rigorous way, does not always lead to the best target version and suggests it would be useful to develop new scales specific to each culture and, at the same time, to think about the trans-cultural adaptation. © 2012 Blackwell Publishing Ltd.

  11. WHO Study on the reliability and validity of the alcohol and drug use disorder instruments: overview of methods and results.

    PubMed

    Ustün, B; Compton, W; Mager, D; Babor, T; Baiyewu, O; Chatterji, S; Cottler, L; Göğüş, A; Mavreas, V; Peters, L; Pull, C; Saunders, J; Smeets, R; Stipec, M R; Vrasti, R; Hasin, D; Room, R; Van den Brink, W; Regier, D; Blaine, J; Grant, B F; Sartorius, N

    1997-09-25

    The WHO Study on the reliability and validity of the alcohol and drug use disorder instruments in an international study which has taken place in centres in ten countries, aiming to test the reliability and validity of three diagnostic instruments for alcohol and drug use disorders: the Composite International Diagnostic Interview (CIDI), the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) and a special version of the Alcohol Use Disorder and Associated Disabilities Interview schedule-alcohol/drug-revised (AUDADIS-ADR). The purpose of the reliability and validity (R&V) study is to further develop the alcohol and drug sections of these instruments so that a range of substance-related diagnoses can be made in a systematic, consistent, and reliable way. The study focuses on new criteria proposed in the tenth revision of the International Classification of Diseases (ICD-10) and the fourth revision of the diagnostic and statistical manual of mental disorders (DSM-IV) for dependence, harmful use and abuse categories for alcohol and psychoactive substance use disorders. A systematic study including a scientifically rigorous measure of reliability (i.e. 1 week test-retest reliability) and validity (i.e. comparison between clinical and non-clinical measures) has been undertaken. Results have yielded useful information on reliability and validity of these instruments at diagnosis, criteria and question level. Overall the diagnostic concordance coefficients (kappa, kappa) were very good for dependence disorders (0.7-0.9), but were somewhat lower for the abuse and harmful use categories. The comparisons among instruments and independent clinical evaluations and debriefing interviews gave important information about possible sources of unreliability, and provided useful clues on the applicability and consistency of nosological concepts across cultures.

  12. Design, Implementation and Case Study of WISEMAN: WIreless Sensors Employing Mobile AgeNts

    NASA Astrophysics Data System (ADS)

    González-Valenzuela, Sergio; Chen, Min; Leung, Victor C. M.

    We describe the practical implementation of Wiseman: our proposed scheme for running mobile agents in Wireless Sensor Networks. Wiseman’s architecture derives from a much earlier agent system originally conceived for distributed process coordination in wired networks. Given the memory constraints associated with small sensor devices, we revised the architecture of the original agent system to make it applicable to this type of networks. Agents are programmed as compact text scripts that are interpreted at the sensor nodes. Wiseman is currently implemented in TinyOS ver. 1, its binary image occupies 19Kbytes of ROM memory, and it occupies 3Kbytes of RAM to operate. We describe the rationale behind Wiseman’s interpreter architecture and unique programming features that can help reduce packet overhead in sensor networks. In addition, we gauge the proposed system’s efficiency in terms of task duration with different network topologies through a case study that involves an early-fire-detection application in a fictitious forest setting.

  13. Factor analysis of the Colombian translation of the Delirium Rating Scale (DRS), Revised-98.

    PubMed

    Franco, José G; Trzepacz, Paula T; Mejía, Mario A; Ochoa, Sol B

    2009-01-01

    The phenomenology of delirium needs further elucidation using validated tools. The authors sought to derive valid factors from the Delirium Rating Scale (DRS), Revised -98. A factor analysis of the DRS-R-98 was performed among 161 medical-surgical patients. Scores ranged from 0 to 7 in 120 patients (74.53%; no delirium), 8 to 13 in 19 (11.80%; subclinical/prodromal delirium), and > or = 14 in 22 (13.66%; delirium). The DSM-IV-TR delirium incidence was 19.87%. The first two rotated factors explained 63.37% of the variance and may correspond to Cognition and Psychosis/Agitation factors. The dimension of motor retardation loaded with cognitive items. Motor agitation and retardation clustered with inattention, which is the cardinal symptom of delirium. The DRS-R-98 has good construct validity in this Latino population.

  14. Psychometric Evaluation of the Revised Michigan Diabetes Knowledge Test (V.2016) in Arabic: Translation and Validation

    PubMed Central

    Alhaiti, Ali Hassan; Alotaibi, Alanod Raffa; Jones, Linda Katherine; DaCosta, Cliff

    2016-01-01

    Objective. To translate the revised Michigan Diabetes Knowledge Test into the Arabic language and examine its psychometric properties. Setting. Of the 139 participants recruited through King Fahad Medical City in Riyadh, Saudi Arabia, 34 agreed to the second-round sample for retesting purposes. Methods. The translation process followed the World Health Organization's guidelines for the translation and adaptation of instruments. All translations were examined for their validity and reliability. Results. The translation process revealed excellent results throughout all stages. The Arabic version received 0.75 for internal consistency via Cronbach's alpha test and excellent outcomes in terms of the test-retest reliability of the instrument with a mean of 0.90 infraclass correlation coefficient. It also received positive content validity index scores. The item-level content validity index for all instrument scales fell between 0.83 and 1 with a mean scale-level index of 0.96. Conclusion. The Arabic version is proven to be a reliable and valid measure of patient's knowledge that is ready to be used in clinical practices. PMID:27995149

  15. Is comorbidity in the eating disorders related to perceptions of parenting? Criterion validity of the revised Young Parenting Inventory.

    PubMed

    Sheffield, Alexandra; Waller, Glenn; Emanuelli, Francesca; Murray, James

    2006-01-01

    Recent studies support the reliability and validity of the Young Parenting Inventory-Revised (YPI-R) and its use in investigating the role of parenting in the aetiology and maintenance of eating pathology. However, criterion validity has yet to be fully established. To investigate one aspect of criterion validity, this study examines the association between parenting and comorbid problems in the eating disorders (including general psychopathology and impulsivity). The participants were 124 women with eating disorders. They completed the YPI-R and the Brief Symptom Inventory (BSI; a measure of general psychopathology). They were also interviewed about their use of a number of impulsive behaviours. YPI-R scales were significant predictors of one of the nine BSI scales, and distinguished those patients who did or did not use specific impulsive behaviours. The criterion validity of the YPI-R is partially supported with regards to general psychopathology and impulsivity. The findings highlight the specificity of the parenting styles measured by the YPI-R, and the need for further research using this tool.

  16. A mobile sensing system for structural health monitoring: design and validation

    NASA Astrophysics Data System (ADS)

    Zhu, Dapeng; Yi, Xiaohua; Wang, Yang; Lee, Kok-Meng; Guo, Jiajie

    2010-05-01

    This paper describes a new approach using mobile sensor networks for structural health monitoring. Compared with static sensors, mobile sensor networks offer flexible system architectures with adaptive spatial resolutions. The paper first describes the design of a mobile sensing node that is capable of maneuvering on structures built with ferromagnetic materials. The mobile sensing node can also attach/detach an accelerometer onto/from the structural surface. The performance of the prototype mobile sensor network has been validated through laboratory experiments. Two mobile sensing nodes are adopted for navigating on a steel portal frame and providing dense acceleration measurements. Transmissibility function analysis is conducted to identify structural damage using data collected by the mobile sensing nodes. This preliminary work is expected to spawn transformative changes in the use of mobile sensors for future structural health monitoring.

  17. Orbital Express AVGS Validation and Calibration for Automated Rendezvous

    NASA Technical Reports Server (NTRS)

    Heaton, Andrew F.; Howard, Richard T.; Pinson, Robin M.

    2008-01-01

    From March to July of 2007, the DARPA Orbital Express mission achieved a number of firsts in autonomous spacecraft operations. The NASA Advanced Video Guidance Sensor (AVGS) was the primary docking sensor during the first two dockings and was used in a blended mode three other automated captures. The AVGS performance exceeded its specification by approximately an order of magnitude. One reason that the AVGS functioned so well during the mission was that the validation and calibration of the sensor prior to the mission advanced the state-of-the-art for proximity sensors. Some factors in this success were improvements in ground test equipment and truth data, the capability for ILOAD corrections for optical and other effects, and the development of a bias correction procedure. Several valuable lessons learned have applications to future proximity sensors.

  18. Fall Risk Assessment Through Automatic Combination of Clinical Fall Risk Factors and Body-Worn Sensor Data.

    PubMed

    Greene, Barry R; Redmond, Stephen J; Caulfield, Brian

    2017-05-01

    Falls are the leading global cause of accidental death and disability in older adults and are the most common cause of injury and hospitalization. Accurate, early identification of patients at risk of falling, could lead to timely intervention and a reduction in the incidence of fall-related injury and associated costs. We report a statistical method for fall risk assessment using standard clinical fall risk factors (N = 748). We also report a means of improving this method by automatically combining it, with a fall risk assessment algorithm based on inertial sensor data and the timed-up-and-go test. Furthermore, we provide validation data on the sensor-based fall risk assessment method using a statistically independent dataset. Results obtained using cross-validation on a sample of 292 community dwelling older adults suggest that a combined clinical and sensor-based approach yields a classification accuracy of 76.0%, compared to either 73.6% for sensor-based assessment alone, or 68.8% for clinical risk factors alone. Increasing the cohort size by adding an additional 130 subjects from a separate recruitment wave (N = 422), and applying the same model building and validation method, resulted in a decrease in classification performance (68.5% for combined classifier, 66.8% for sensor data alone, and 58.5% for clinical data alone). This suggests that heterogeneity between cohorts may be a major challenge when attempting to develop fall risk assessment algorithms which generalize well. Independent validation of the sensor-based fall risk assessment algorithm on an independent cohort of 22 community dwelling older adults yielded a classification accuracy of 72.7%. Results suggest that the present method compares well to previously reported sensor-based fall risk assessment methods in assessing falls risk. Implementation of objective fall risk assessment methods on a large scale has the potential to improve quality of care and lead to a reduction in associated hospital costs, due to fewer admissions and reduced injuries due to falling.

  19. Psychometric Properties of the Revised Developmental Coordination Disorder Questionnaire

    ERIC Educational Resources Information Center

    Wilson, Brenda N.; Crawford, Susan G.; Green, Dido; Roberts, Gwen; Aylott, Alice; Kaplan, Bonnie J.

    2009-01-01

    The Developmental Coordination Disorder Questionnaire (DCDQ) is a parent-completed measure designed to identify subtle motor problems in children of 8 to 14.6 years of age. The purpose of this study was to extend the lower age range to children aged 5 to 7 years, revise items to ensure clarity, develop new scoring, and evaluate validity of the…

  20. Racial/Ethnic Differences in Dietary Intake among WIC Families Prior to Food Package Revisions

    ERIC Educational Resources Information Center

    Kong, Angela; Odoms-Young, Angela M.; Schiffer, Linda A.; Berbaum, Michael L.; Porter, Summer J.; Blumstein, Lara; Fitzgibbon, Marian L.

    2013-01-01

    Objective: To compare the diets of African American and Hispanic families in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) prior to the 2009 food package revisions. Methods: Mother-child dyads were recruited from 12 WIC sites in Chicago, IL. Individuals with 1 valid 24-hour recall were included in the analyses…

  1. Psychometric Validation of the Brief Adaptation to Disability Scale-Revised for Persons with Spinal Cord Injury in Taiwan

    ERIC Educational Resources Information Center

    Lin, Chen-Ping; Wang, Chia-Chiang; Fujikawa, Mayu; Brooks, Jessica; Eastvold-Walton, Lissa; Maxwell, Kristin; Chan, Fong

    2013-01-01

    Purpose: To examine the measurement structure of the Brief Adaptation to Disability Scale-Revised (B-ADS-R). Measure: A 12-item measure of disability acceptance based on the four value changes (enlarging the scope of values, containing the effects of the disability, subordinating the physique, and transforming comparative-status values to asset…

  2. Psychometric Properties of the School Attitude Assessment Survey-Revised with International Baccalaureate High School Students

    ERIC Educational Resources Information Center

    Dedrick, Robert F.; Shaunessy-Dedrick, Elizabeth; Suldo, Shannon M.; Ferron, John M.

    2015-01-01

    In two studies (ns = 312 and 1,149) with 9- to 12-grade students in pre-International Baccalaureate (IB) and IB Diploma programs, we evaluated the reliability, factor structure, measurement invariance, and criterion-related validity of the scores from the School Attitude Assessment Survey-Revised (SAAS-R). Reliabilities of the five SAAS-R subscale…

  3. Further Empirical Data on the Psychoeducational Profile-Revised (PEP-R): Reliability and Validation with the Vineland Adaptive Behavior Scales

    ERIC Educational Resources Information Center

    Villa, Susanna; Micheli, Enrico; Villa, Laura; Pastore, Valentina; Crippa, Alessandro; Molteni, Massimo

    2010-01-01

    The PEP-R (psychoeducational profile revised) is an instrument that has been used in many countries to assess abilities and formulate treatment programs for children with autism and related developmental disorders. To the end to provide further information on the PEP-R's psychometric properties, a large sample (N = 137) of children presenting…

  4. Testing Math or Testing Language? The Construct Validity of the KeyMath-Revised for Children with Intellectual Disability and Language Difficulties

    ERIC Educational Resources Information Center

    Rhodes, Katherine T.; Branum-Martin, Lee; Morris, Robin D.; Romski, MaryAnn; Sevcik, Rose A.

    2015-01-01

    Although it is often assumed that mathematics ability alone predicts mathematics test performance, linguistic demands may also predict achievement. This study examined the role of language in mathematics assessment performance for children with intellectual disability (ID) at less severe levels, on the KeyMath-Revised Inventory (KM-R) with a…

  5. A Follow-Up Study of "Teacher Beliefs Survey": A Psychometric Investigation of the Instrument and Its Educational Implications.

    ERIC Educational Resources Information Center

    Benjamin, Jane; Petersen, Naomi Jeffery; Sink, Chris; Walker, Brenda

    The construct validity of the revised Teacher Beliefs Survey (TBS) (S. Woolley and A. Woolley, 1999) was examined, and the populations that can use this instrument reliably were explored in this study. The TBS was designed to identify the dimensions of classroom practices. The revised instrument, which contained additional subscale items, was…

  6. Polychlorinated Biphenyl (PCB) Aroclor Data Validation, SOP No. HW-37A Revision 0; SOM02.2

    EPA Pesticide Factsheets

    This document is designed to offer the data reviewer guidance in determining the validity of analytical data generated through the USEPA Contract Laboratory Program (CLP) Statement of Work (SOW) for Multi-Media, Multi-Concentration Organics Analysis

  7. 78 FR 13086 - Agency Information Collection Activities; Submission for OMB Review; Comment Request...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-26

    ... for OMB Review; Comment Request; Unemployment Insurance Data Validation Program ACTION: Notice...) sponsored information collection request (ICR) revision titled, ``Unemployment Insurance Data Validation....gov . Authority: 44 U.S.C. 3507(a)(1)(D). SUPPLEMENTARY INFORMATION: The Unemployment Insurance Data...

  8. Refining a learning progression of energy

    NASA Astrophysics Data System (ADS)

    Yao, Jian-Xin; Guo, Yu-Ying; Neumann, Knut

    2017-11-01

    This paper presents a revised learning progression for the energy concept and initial findings on diverse progressions among subgroups of sample students. The revised learning progression describes how students progress towards an understanding of the energy concept along two progress variables identified from previous studies - key ideas about energy and levels of conceptual development. To assess students understanding with respect to the revised learning progression, we created a specific instrument, the Energy Concept Progression Assessment (ECPA) based on previous work on assessing students' understanding of energy. After iteratively refining the instrument in two pilot studies, the ECPA was administered to a total of 4550 students (Grades 8-12) from schools in two districts in a major city in Mainland China. Rasch analysis was used to examine the validity of the revised learning progression and explore factors explaining different progressions. Our results confirm the validity of the four conceptual development levels. In addition, we found that although following a similar progression pattern, students' progression rate was significantly influenced by environmental factors such as school type. In the discussion of our findings, we address the non-linear and complex nature of students' progression in understanding energy. We conclude with illuminating our research's implication for curriculum design and energy teaching.

  9. Validating survey measurement scales for AIDS-related knowledge and stigma among construction workers in South Africa.

    PubMed

    Bowen, Paul; Govender, Rajen; Edwards, Peter

    2016-01-23

    Construction workers in South Africa are regarded as a high-risk group in the context of HIV/AIDS. HIV testing is pivotal to controlling HIV transmission and providing palliative care and AIDS-related knowledge and stigma are key issues in addressing the likelihood of testing behaviour. In exploring these issues, various studies have employed an 11-item AIDS-related knowledge scale (Kalichman and Simbayi, AIDS Care 16:572-580, 2004) and a 9-item stigma scale (Kalichman et al., AIDS Behav 9:135-143, 2005), but little evidence exists confirming the psychometric properties of these scales. Using survey data from 512 construction workers in the Western Cape, South Africa, this research examines the validity and reliability of the two scales through exploratory and confirmatory factor analysis and internal consistency tests. From confirmatory factor analysis, a revised 10-item knowledge scale was developed (χ2 /df ratio = 1.675, CFI = 0.982, RMSEA = 0.038, and Hoelter (95 %) = 393). A revised 8-item stigma scale was also developed (χ2 /df ratio = 1.929, CFI = 0.974, RMSEA = 0.045, and Hoelter (95 %) = 380). Both revised scales demonstrated good model fit and all factor loadings were significant (p < 0.01). Reliability analysis demonstrated excellent to good internal consistency, with alpha values of 0.80 and 0.74, respectively. Both revised scales also demonstrated satisfactory convergent and divergent validity. Limitations of the original survey from which the data was obtained include the failure to properly account for respondent selection of language for completion of the survey, use of ethnicity as a proxy for identifying the native language of participants, the limited geographical area from which the survey data was collected, and the limitations associated with the convenience sample. A limitation of the validation study was the lack of available data for a more robust examination of reliability beyond internal consistency, such as test-retest reliability. The revised knowledge and stigma scales offered here hold considerable promise as measures of AIDS-related knowledge and stigma among South African construction workers.

  10. Reliability, Validity, and Factor Structure of the Current Assessment Practice Evaluation-Revised (CAPER) in a National Sample.

    PubMed

    Lyon, Aaron R; Pullmann, Michael D; Dorsey, Shannon; Martin, Prerna; Grigore, Alexandra A; Becker, Emily M; Jensen-Doss, Amanda

    2018-05-11

    Measurement-based care (MBC) is an increasingly popular, evidence-based practice, but there are no tools with established psychometrics to evaluate clinician use of MBC practices in mental health service delivery. The current study evaluated the reliability, validity, and factor structure of scores generated from a brief, standardized tool to measure MBC practices, the Current Assessment Practice Evaluation-Revised (CAPER). Survey data from a national sample of 479 mental health clinicians were used to conduct exploratory and confirmatory factor analyses, as well as reliability and validity analyses (e.g., relationships between CAPER subscales and clinician MBC attitudes). Analyses revealed competing two- and three-factor models. Regardless of the model used, scores from CAPER subscales demonstrated good reliability and convergent and divergent validity with MBC attitudes in the expected directions. The CAPER appears to be a psychometrically sound tool for assessing clinician MBC practices. Future directions for development and application of the tool are discussed.

  11. Neighborhood Quality and Attachment: Validation of the Revised Residential Environment Assessment Tool.

    PubMed

    Poortinga, Wouter; Calve, Tatiana; Jones, Nikki; Lannon, Simon; Rees, Tabitha; Rodgers, Sarah E; Lyons, Ronan A; Johnson, Rhodri

    2017-04-01

    Various studies have shown that neighborhood quality is linked to neighborhood attachment and satisfaction. However, most have relied upon residents' own perceptions rather than independent observations of the neighborhood environment. This study examines the reliability and validity of the revised Residential Environment Assessment Tool (REAT 2.0), an audit instrument covering both public and private spaces of the neighborhood environment. The research shows that REAT 2.0 is a reliable, easy-to-use instrument and that most underlying constructs can be validated against residents' own neighborhood perceptions. The convergent validity of the instrument, which was tested against digital map data, can be improved for a number of miscellaneous urban form items. The research further found that neighborhood attachment was significantly associated with the overall REAT 2.0 score. This association can mainly be attributed to the property-level neighborhood quality and natural elements components. The research demonstrates the importance of private spaces in the outlook of the neighborhood environment.

  12. A Spanish validation of the Coma Recovery Scale-Revised (CRS-R).

    PubMed

    Tamashiro, Mercedes; Rivas, Maria Elisa; Ron, Melania; Salierno, Fernando; Dalera, Marisol; Olmos, Lisandro

    2014-01-01

    Analysis of inter-rater reliability and concurrent validity. To determine measurement properties of a Spanish version of The Coma Recovery Scale-Revised (CRS-R). A sample of 35 in-patients with severe acquired brain injury. To test concurrent validity of the translated scale, the Glasgow Coma Scale (GSC) and Disability Rating Scale (DRS) were also administered. Two experts in the field were recruited to assess inter-rater agreement. Inter-rater reliability was good for total CRS-R scores (Cronbach α = 0.973, p = 0.001). Sub-scale analysis showed moderate-to-high inter-rater agreement. Total CRS-R scores correlated significantly (p < 0.05) with total GCS (r = 0.74) and DRS (r = 0.54) scores, indicating acceptable concurrent validity. The Spanish version of CRS-R can be administered reliably by trained and experienced examiners. CRS-R appears capable of differentiating patients in Emergence from Minimally Conscious State (EMCS) or in Minimally Conscious State (MCS) from those in a Vegetative State (VS).

  13. Dependence and physical exercise: Spanish validation of the Exercise Dependence Scale-Revised (EDS-R).

    PubMed

    Sicilia, Alvaro; González-Cutre, David

    2011-05-01

    The purpose of this study was to validate the Spanish version of the Exercise Dependence Scale-Revised (EDS-R). To achieve this goal, a sample of 531 sport center users was used and the psychometric properties of the EDS-R were examined through different analyses. The results supported both the first-order seven-factor model and the higher-order model (seven first-order factors and one second-order factor). The structure of both models was invariant across age. Correlations among the subscales indicated a related factor model, supporting construct validity of the scale. Alpha values over .70 (except for Reduction in Other Activities) and suitable levels of temporal stability were obtained. Users practicing more than three days per week had higher scores in all subscales than the group practicing with a frequency of three days or fewer. The findings of this study provided reliability and validity for the EDS-R in a Spanish context.

  14. Fault detection, isolation, and diagnosis of self-validating multifunctional sensors.

    PubMed

    Yang, Jing-Li; Chen, Yin-Sheng; Zhang, Li-Li; Sun, Zhen

    2016-06-01

    A novel fault detection, isolation, and diagnosis (FDID) strategy for self-validating multifunctional sensors is presented in this paper. The sparse non-negative matrix factorization-based method can effectively detect faults by using the squared prediction error (SPE) statistic, and the variables contribution plots based on SPE statistic can help to locate and isolate the faulty sensitive units. The complete ensemble empirical mode decomposition is employed to decompose the fault signals to a series of intrinsic mode functions (IMFs) and a residual. The sample entropy (SampEn)-weighted energy values of each IMFs and the residual are estimated to represent the characteristics of the fault signals. Multi-class support vector machine is introduced to identify the fault mode with the purpose of diagnosing status of the faulty sensitive units. The performance of the proposed strategy is compared with other fault detection strategies such as principal component analysis, independent component analysis, and fault diagnosis strategies such as empirical mode decomposition coupled with support vector machine. The proposed strategy is fully evaluated in a real self-validating multifunctional sensors experimental system, and the experimental results demonstrate that the proposed strategy provides an excellent solution to the FDID research topic of self-validating multifunctional sensors.

  15. A Formal Approach to the Selection by Minimum Error and Pattern Method for Sensor Data Loss Reduction in Unstable Wireless Sensor Network Communications

    PubMed Central

    Kim, Changhwa; Shin, DongHyun

    2017-01-01

    There are wireless networks in which typically communications are unsafe. Most terrestrial wireless sensor networks belong to this category of networks. Another example of an unsafe communication network is an underwater acoustic sensor network (UWASN). In UWASNs in particular, communication failures occur frequently and the failure durations can range from seconds up to a few hours, days, or even weeks. These communication failures can cause data losses significant enough to seriously damage human life or property, depending on their application areas. In this paper, we propose a framework to reduce sensor data loss during communication failures and we present a formal approach to the Selection by Minimum Error and Pattern (SMEP) method that plays the most important role for the reduction in sensor data loss under the proposed framework. The SMEP method is compared with other methods to validate its effectiveness through experiments using real-field sensor data sets. Moreover, based on our experimental results and performance comparisons, the SMEP method has been validated to be better than others in terms of the average sensor data value error rate caused by sensor data loss. PMID:28498312

  16. A Formal Approach to the Selection by Minimum Error and Pattern Method for Sensor Data Loss Reduction in Unstable Wireless Sensor Network Communications.

    PubMed

    Kim, Changhwa; Shin, DongHyun

    2017-05-12

    There are wireless networks in which typically communications are unsafe. Most terrestrial wireless sensor networks belong to this category of networks. Another example of an unsafe communication network is an underwater acoustic sensor network (UWASN). In UWASNs in particular, communication failures occur frequently and the failure durations can range from seconds up to a few hours, days, or even weeks. These communication failures can cause data losses significant enough to seriously damage human life or property, depending on their application areas. In this paper, we propose a framework to reduce sensor data loss during communication failures and we present a formal approach to the Selection by Minimum Error and Pattern (SMEP) method that plays the most important role for the reduction in sensor data loss under the proposed framework. The SMEP method is compared with other methods to validate its effectiveness through experiments using real-field sensor data sets. Moreover, based on our experimental results and performance comparisons, the SMEP method has been validated to be better than others in terms of the average sensor data value error rate caused by sensor data loss.

  17. Meta-Analysis of Armed service Vocational Aptitude Battery Subtest Validity Data

    DTIC Science & Technology

    1988-12-01

    underprivelaged groups ( Gottfredson , 1986). Revisionist beliefs are similar, yet are more extreme. They contend that intelligence and educational...correlation with intelligence measures (.6) 18 ( Gottfredson , 1986). Attempts at social revisions with the dual goals of increasing both equality and... intelligence measures. The ASVAB will then be described in terms of its history, content, reliability, and validity. Lastly, validity generalization and

  18. An improved snow scheme for the ECMWF land surface model: Description and offline validation

    Treesearch

    Emanuel Dutra; Gianpaolo Balsamo; Pedro Viterbo; Pedro M. A. Miranda; Anton Beljaars; Christoph Schar; Kelly Elder

    2010-01-01

    A new snow scheme for the European Centre for Medium-Range Weather Forecasts (ECMWF) land surface model has been tested and validated. The scheme includes a new parameterization of snow density, incorporating a liquid water reservoir, and revised formulations for the subgrid snow cover fraction and snow albedo. Offline validation (covering a wide range of spatial and...

  19. Design, development and method validation of a novel multi-resonance microwave sensor for moisture measurement.

    PubMed

    Peters, Johanna; Taute, Wolfgang; Bartscher, Kathrin; Döscher, Claas; Höft, Michael; Knöchel, Reinhard; Breitkreutz, Jörg

    2017-04-08

    Microwave sensor systems using resonance technology at a single resonance in the range of 2-3 GHz have been shown to be a rapid and reliable tool for moisture determination in solid materials including pharmaceutical granules. So far, their application is limited to lower moisture ranges or limitations above certain moisture contents had to be accepted. Aim of the present study was to develop a novel multi-resonance sensor system in order to expand the measurement range. Therefore, a novel sensor using additional resonances over a wide frequency band was designed and used to investigate inherent limitations of first generation sensor systems and material-related limits. Using granule samples with different moisture contents, an experimental protocol for calibration and validation of the method was established. Pursuant to this protocol, a multiple linear regression (MLR) prediction model built by correlating microwave moisture values to the moisture determined by Karl Fischer titration was chosen and rated using conventional criteria such as coefficient of determination (R 2 ) and root mean square error of calibration (RMSEC). Using different operators, different analysis dates and different ambient conditions the method was fully validated following the guidance of ICH Q2(R1). The study clearly showed explanations for measurement uncertainties of first generation sensor systems which confirmed the approach to overcome these by using additional resonances. The established prediction model could be validated in the range of 7.6-19.6%, demonstrating its fit for its future purpose, the moisture content determination during wet granulations. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Evaluation of Micronutrient Sensors for Food Matrices in Resource-Limited Settings: A Systematic Narrative Review.

    PubMed

    Waller, Anna W; Lotton, Jennifer L; Gaur, Shashank; Andrade, Jeanette M; Andrade, Juan E

    2018-06-21

    In resource-limited settings, mass food fortification is a common strategy to ensure the population consumes appropriate quantities of essential micronutrients. Food and government organizations in these settings, however, lack tools to monitor the quality and compliance of fortified products and their efficacy to enhance nutrient status. The World Health Organization has developed general guidelines known as ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable to end-users) to aid the development of useful diagnostic tools for these settings. These guidelines assume performance aspects such as sufficient accuracy, reliability, and validity. The purpose of this systematic narrative review is to examine the micronutrient sensor literature on its adherence towards the ASSURED criteria along with accuracy, reliability, and validation when developing micronutrient sensors for resource-limited settings. Keyword searches were conducted in three databases: Web of Science, PubMed, and Scopus and were based on 6-point inclusion criteria. A 16-question quality assessment tool was developed to determine the adherence towards quality and performance criteria. Of the 2,365 retrieved studies, 42 sensors were included based on inclusion/exclusion criteria. Results showed that improvements to the current sensor design are necessary, especially their affordability, user-friendliness, robustness, equipment-free, and deliverability within the ASSURED criteria, and accuracy and validity of the additional criteria to be useful in resource-limited settings. Although it requires further validation, the 16-question quality assessment tool can be used as a guide in the development of sensors for resource-limited settings. © 2018 Institute of Food Technologists®.

  1. Validity and reliability of Persian version of Listening Styles Profile-Revised (LSP- R) in Iranian students.

    PubMed

    Fatehi, Zahra; Baradaran, Hamid Reza; Asadpour, Mohamad; Rezaeian, Mohsen

    2017-01-01

    Background: Individuals' listening styles differs based on their characters, professions and situations. This study aimed to assess the validity and reliability of Listening Styles Profile- Revised (LSP- R) in Iranian students. Methods: After translating into Persian, LSP-R was employed in a sample of 240 medical and nursing Persian speaking students in Iran. Statistical analysis was performed to test the reliability and validity of the LSP-R. Results: The study revealed high internal consistency and good test-retest reliability for the Persian version of the questionnaire. The Cronbach's alpha coefficient was 0.72 and intra-class correlation coefficient 0.87. The means for the content validity index and the content validity ratio (CVR) were 0.90 and 0.83, respectively. Exploratory factor analysis (EFA) yielded a four-factor solution accounted for 60.8% of the observed variance. Majority of medical students (73%) as well as majority of nursing students (70%) stated that their listening styles were task-oriented. Conclusion: In general, the study finding suggests that the Persian version of LSP-R is a valid and reliable instrument for assessing listening styles profile in the studied sample.

  2. Development of a Sensor Node for Precision Horticulture

    PubMed Central

    López, Juan A.; Soto, Fulgencio; Sánchez, Pedro; Iborra, Andrés; Suardiaz, Juan; Vera, Juan A.

    2009-01-01

    This paper presents the design of a new wireless sensor node (GAIA Soil-Mote) for precision horticulture applications which permits the use of precision agricultural instruments based on the SDI-12 standard. Wireless communication is achieved with a transceiver compliant with the IEEE 802.15.4 standard. The GAIA Soil-Mote software implementation is based on TinyOS. A two-phase methodology was devised to validate the design of this sensor node. The first phase consisted of laboratory validation of the proposed hardware and software solution, including a study on power consumption and autonomy. The second phase consisted of implementing a monitoring application in a real broccoli (Brassica oleracea L. var Marathon) crop in Campo de Cartagena in south-east Spain. In this way the sensor node was validated in real operating conditions. This type of application was chosen because there is a large potential market for it in the farming sector, especially for the development of precision agriculture applications. PMID:22412309

  3. Development of a sensor node for precision horticulture.

    PubMed

    López, Juan A; Soto, Fulgencio; Sánchez, Pedro; Iborra, Andrés; Suardiaz, Juan; Vera, Juan A

    2009-01-01

    This paper presents the design of a new wireless sensor node (GAIA Soil-Mote) for precision horticulture applications which permits the use of precision agricultural instruments based on the SDI-12 standard. Wireless communication is achieved with a transceiver compliant with the IEEE 802.15.4 standard. The GAIA Soil-Mote software implementation is based on TinyOS. A two-phase methodology was devised to validate the design of this sensor node. The first phase consisted of laboratory validation of the proposed hardware and software solution, including a study on power consumption and autonomy. The second phase consisted of implementing a monitoring application in a real broccoli (Brassica oleracea L. var Marathon) crop in Campo de Cartagena in south-east Spain. In this way the sensor node was validated in real operating conditions. This type of application was chosen because there is a large potential market for it in the farming sector, especially for the development of precision agriculture applications.

  4. Development and validation of the Australian version of the Birth Satisfaction Scale-Revised (BSS-R).

    PubMed

    Jefford, Elaine; Hollins Martin, Caroline J; Martin, Colin R

    2018-02-01

    The 10-item Birth Satisfaction Scale-Revised (BSS-R) has recently been endorsed by international expert consensus for global use as the birth satisfaction outcome measure of choice. English-language versions of the tool include validated UK and US versions; however, the instrument has not, to date, been contextualised and validated in an Australian English-language version. The current investigation sought to develop and validate an English-language version of the tool for use within the Australian context. A two-stage study. Following review and modification by expert panel, the Australian BSS-R (A-BSS-R) was (Stage 1) evaluated for factor structure, internal consistency, known-groups discriminant validity and divergent validity. Stage 2 directly compared the A-BSS-R data set with the original UK data set to determine the invariance characteristics of the new instrument. Participants were a purposive sample of Australian postnatal women (n = 198). The A-BSS-R offered a good fit to data consistent with the BSS-R tridimensional measurement model and was found to be conceptually and measurement equivalent to the UK version. The A-BSS-R demonstrated excellent known-groups discriminant validity, generally good divergent validity and overall good internal consistency. The A-BSS-R represents a robust and valid measure of the birth satisfaction concept suitable for use within Australia and appropriate for application to International comparative studies.

  5. Spatial interpolation quality assessments for soil sensor transect datasets

    USDA-ARS?s Scientific Manuscript database

    Near-ground geophysical soil sensors provide extremely valuable information for precision agriculture applications. Indeed, their readings can be used as proxy for many soil parameters. Typically, leave-one-out (loo) cross-validation (CV) of spatial interpolation of sensor data returns overly optimi...

  6. Report on International Spaceborne Imaging Spectroscopy Technical Committee Calibration and Validation Workshop, National Environment Research Council Field Spectroscopy Facility, University of Edinburgh

    NASA Technical Reports Server (NTRS)

    Ong, C,; Mueller, A.; Thome, K.; Bachmann, M.; Czapla-Myers, J.; Holzwarth, S.; Khalsa, S. J.; Maclellan, C.; Malthus, T.; Nightingale, J.; hide

    2016-01-01

    Calibration and validation are fundamental for obtaining quantitative information from Earth Observation (EO) sensor data. Recognising this and the impending launch of at least five sensors in the next five years, the International Spaceborne Imaging Spectroscopy Technical Committee instigated a calibration and validation initiative. A workshop was conducted recently as part of this initiative with the objective of establishing a good practice framework for radiometric and spectral calibration and validation in support of spaceborne imaging spectroscopy missions. This paper presents the outcomes and recommendations for future work arising from the workshop.

  7. Modification, validation and implementation of a protocol for post-thyroidectomy hypocalcaemia.

    PubMed

    Stedman, T; Chew, P; Truran, P; Lim, C B; Balasubramanian, S P

    2018-02-01

    Introduction The management of post-thyroidectomy hypocalcaemia should facilitate early discharge, and reduce risks of hypocalcaemia, readmission and treatment related hypercalcaemia. This paper describes the implementation, evaluation and revision a protocol for the optimal management of this condition. Methods Day 1 parathyroid hormone (PTH) measurements in addition to calcium measurements were commenced following review of the unit's outcomes and literature on post-thyroidectomy hypocalcaemia. Outcomes from a three-year cohort of patients undergoing thyroid surgery helped amend this protocol (revision 1) to reduce biochemical tests, stipulate the need, nature and dose of vitamin D/calcium supplements, and encourage early discharge. This was further validated over seven months to assess compliance, episodes of hyper and/or hypocalcaemia after discharge, readmissions and need for treatment changes. Further revisions were made (revision 2) and implemented. Results The temporary and long-term postoperative hypocalcaemia rates were 29.1% and 3.2% respectively. Repeat calcium measurements on the first day altered management in only 1.4% of cases. The revised protocol was adhered to in 90% of cases. One patient had hypocalcaemia (due to non-compliance) and one had hypercalcaemia. Revision 2 involved reducing the dose of calcium. Conclusions This is a good example of a unit protocol for post-thyroidectomy hypocalcaemia being developed and modified on the basis of the literature and local experience. Day 1 PTH and calcium levels determine the need for treatment and frequency of follow-up visits, facilitate early discharge, reduce risk of over and/or undertreatment, and are good indicators of permanent hypocalcaemia.

  8. Crack Detection in Fibre Reinforced Plastic Structures Using Embedded Fibre Bragg Grating Sensors: Theory, Model Development and Experimental Validation

    PubMed Central

    Pereira, G. F.; Mikkelsen, L. P.; McGugan, M.

    2015-01-01

    In a fibre-reinforced polymer (FRP) structure designed using the emerging damage tolerance and structural health monitoring philosophy, sensors and models that describe crack propagation will enable a structure to operate despite the presence of damage by fully exploiting the material’s mechanical properties. When applying this concept to different structures, sensor systems and damage types, a combination of damage mechanics, monitoring technology, and modelling is required. The primary objective of this article is to demonstrate such a combination. This article is divided in three main topics: the damage mechanism (delamination of FRP), the structural health monitoring technology (fibre Bragg gratings to detect delamination), and the finite element method model of the structure that incorporates these concepts into a final and integrated damage-monitoring concept. A novel method for assessing a crack growth/damage event in fibre-reinforced polymer or structural adhesive-bonded structures using embedded fibre Bragg grating (FBG) sensors is presented by combining conventional measured parameters, such as wavelength shift, with parameters associated with measurement errors, typically ignored by the end-user. Conjointly, a novel model for sensor output prediction (virtual sensor) was developed using this FBG sensor crack monitoring concept and implemented in a finite element method code. The monitoring method was demonstrated and validated using glass fibre double cantilever beam specimens instrumented with an array of FBG sensors embedded in the material and tested using an experimental fracture procedure. The digital image correlation technique was used to validate the model prediction by correlating the specific sensor response caused by the crack with the developed model. PMID:26513653

  9. O and temperature in high-pressure and -temperature gases

    NASA Astrophysics Data System (ADS)

    Goldenstein, C. S.; Spearrin, R. M.; Jeffries, J. B.; Hanson, R. K.

    2014-09-01

    The design and validation of a tunable diode laser (TDL) sensor for temperature and H2O in high-pressure and -temperature gases are presented. High-fidelity measurements are enabled through the use of: (1) strong H2O fundamental-band absorption near 2.5 μm, (2) calibration-free first-harmonic-normalized wavelength-modulation spectroscopy with second-harmonic detection (WMS-2 f/1 f), (3) an experimentally derived and validated spectroscopic database, and (4) a new approach to selecting the optimal wavelength and modulation depth of each laser. This sensor uses two TDLs near 2,474 and 2,482 nm that were fiber coupled in free space and frequency multiplexed to enable measurements along a single line-of-sight. The lasers were modulated at 35 and 45.5 kHz, respectively, to achieve a sensor bandwidth of 4.5 kHz. This sensor was validated in a shock tube at temperatures and pressures ranging from 1,000 to 2,700 K and 8 to 50 bar. There the sensor resolved transients and recovered the known steady-state temperature and H2O mole fraction with a precision of 3.2 and 2.6 % RMS, respectively.

  10. Tsunami Forecasting and Monitoring in New Zealand

    NASA Astrophysics Data System (ADS)

    Power, William; Gale, Nora

    2011-06-01

    New Zealand is exposed to tsunami threats from several sources that vary significantly in their potential impact and travel time. One route for reducing the risk from these tsunami sources is to provide advance warning based on forecasting and monitoring of events in progress. In this paper the National Tsunami Warning System framework, including the responsibilities of key organisations and the procedures that they follow in the event of a tsunami threatening New Zealand, are summarised. A method for forecasting threat-levels based on tsunami models is presented, similar in many respects to that developed for Australia by Allen and Greenslade (Nat Hazards 46:35-52, 2008), and a simple system for easy access to the threat-level forecasts using a clickable pdf file is presented. Once a tsunami enters or initiates within New Zealand waters, its progress and evolution can be monitored in real-time using a newly established network of online tsunami gauge sensors placed at strategic locations around the New Zealand coasts and offshore islands. Information from these gauges can be used to validate and revise forecasts, and assist in making the all-clear decision.

  11. Real-time motion artifacts compensation of ToF sensors data on GPU

    NASA Astrophysics Data System (ADS)

    Lefloch, Damien; Hoegg, Thomas; Kolb, Andreas

    2013-05-01

    Over the last decade, ToF sensors attracted many computer vision and graphics researchers. Nevertheless, ToF devices suffer from severe motion artifacts for dynamic scenes as well as low-resolution depth data which strongly justifies the importance of a valid correction. To counterbalance this effect, a pre-processing approach is introduced to greatly improve range image data on dynamic scenes. We first demonstrate the robustness of our approach using simulated data to finally validate our method using sensor range data. Our GPU-based processing pipeline enhances range data reliability in real-time.

  12. A Digital Sensor Simulator of the Pushbroom Offner Hyperspectral Imaging Spectrometer

    PubMed Central

    Tao, Dongxing; Jia, Guorui; Yuan, Yan; Zhao, Huijie

    2014-01-01

    Sensor simulators can be used in forecasting the imaging quality of a new hyperspectral imaging spectrometer, and generating simulated data for the development and validation of the data processing algorithms. This paper presents a novel digital sensor simulator for the pushbroom Offner hyperspectral imaging spectrometer, which is widely used in the hyperspectral remote sensing. Based on the imaging process, the sensor simulator consists of a spatial response module, a spectral response module, and a radiometric response module. In order to enhance the simulation accuracy, spatial interpolation-resampling, which is implemented before the spatial degradation, is developed to compromise the direction error and the extra aliasing effect. Instead of using the spectral response function (SRF), the dispersive imaging characteristics of the Offner convex grating optical system is accurately modeled by its configuration parameters. The non-uniformity characteristics, such as keystone and smile effects, are simulated in the corresponding modules. In this work, the spatial, spectral and radiometric calibration processes are simulated to provide the parameters of modulation transfer function (MTF), SRF and radiometric calibration parameters of the sensor simulator. Some uncertainty factors (the stability, band width of the monochromator for the spectral calibration, and the integrating sphere uncertainty for the radiometric calibration) are considered in the simulation of the calibration process. With the calibration parameters, several experiments were designed to validate the spatial, spectral and radiometric response of the sensor simulator, respectively. The experiment results indicate that the sensor simulator is valid. PMID:25615727

  13. Operational calibration and validation of landsat data continuity mission (LDCM) sensors using the image assessment system (IAS)

    USGS Publications Warehouse

    Micijevic, Esad; Morfitt, Ron

    2010-01-01

    Systematic characterization and calibration of the Landsat sensors and the assessment of image data quality are performed using the Image Assessment System (IAS). The IAS was first introduced as an element of the Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+) ground segment and recently extended to Landsat 4 (L4) and 5 (L5) Thematic Mappers (TM) and Multispectral Sensors (MSS) on-board the Landsat 1-5 satellites. In preparation for the Landsat Data Continuity Mission (LDCM), the IAS was developed for the Earth Observer 1 (EO-1) Advanced Land Imager (ALI) with a capability to assess pushbroom sensors. This paper describes the LDCM version of the IAS and how it relates to unique calibration and validation attributes of its on-board imaging sensors. The LDCM IAS system will have to handle a significantly larger number of detectors and the associated database than the previous IAS versions. An additional challenge is that the LDCM IAS must handle data from two sensors, as the LDCM products will combine the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) spectral bands.

  14. Is Structured Observation a Valid Technique to Measure Handwashing Behavior? Use of Acceleration Sensors Embedded in Soap to Assess Reactivity to Structured Observation

    PubMed Central

    Ram, Pavani K.; Halder, Amal K.; Granger, Stewart P.; Jones, Therese; Hall, Peter; Hitchcock, David; Wright, Richard; Nygren, Benjamin; Islam, M. Sirajul; Molyneaux, John W.; Luby, Stephen P.

    2010-01-01

    Structured observation is often used to evaluate handwashing behavior. We assessed reactivity to structured observation in rural Bangladesh by distributing soap containing acceleration sensors and performing structured observation 4 days later. Sensors recorded the number of times soap was moved. In 45 participating households, the median number of sensor soap movements during the 5-hour time block on pre-observation days was 3.7 (range 0.3–10.6). During the structured observation, the median number of sensor soap movements was 5.0 (range 0–18.0), a 35% increase, P = 0.0004. Compared with the same 5-hour time block on pre-observation days, the number of sensor soap movements increased during structured observation by ≥ 20% in 62% of households, and by ≥ 100% in 22% of households. The increase in sensor soap movements during structured observation, compared with pre-observation days, indicates substantial reactivity to the presence of the observer. These findings call into question the validity of structured observation for measurement of handwashing behavior. PMID:21036840

  15. Is structured observation a valid technique to measure handwashing behavior? Use of acceleration sensors embedded in soap to assess reactivity to structured observation.

    PubMed

    Ram, Pavani K; Halder, Amal K; Granger, Stewart P; Jones, Therese; Hall, Peter; Hitchcock, David; Wright, Richard; Nygren, Benjamin; Islam, M Sirajul; Molyneaux, John W; Luby, Stephen P

    2010-11-01

    Structured observation is often used to evaluate handwashing behavior. We assessed reactivity to structured observation in rural Bangladesh by distributing soap containing acceleration sensors and performing structured observation 4 days later. Sensors recorded the number of times soap was moved. In 45 participating households, the median number of sensor soap movements during the 5-hour time block on pre-observation days was 3.7 (range 0.3-10.6). During the structured observation, the median number of sensor soap movements was 5.0 (range 0-18.0), a 35% increase, P = 0.0004. Compared with the same 5-hour time block on pre-observation days, the number of sensor soap movements increased during structured observation by ≥ 20% in 62% of households, and by ≥ 100% in 22% of households. The increase in sensor soap movements during structured observation, compared with pre-observation days, indicates substantial reactivity to the presence of the observer. These findings call into question the validity of structured observation for measurement of handwashing behavior.

  16. A review and update of the Health of the Nation Outcome Scales (HoNOS).

    PubMed

    James, Mick; Painter, Jon; Buckingham, Bill; Stewart, Malcolm W

    2018-04-01

    Aims and method The Health of the Nation Outcome Scales (HoNOS) and its older adults' version (HoNOS 65+) have been used widely for 20 years, but their glossaries have not been revised to reflect clinicians' experiences or changes in service delivery. The Royal College of Psychiatrists convened an international advisory board, with UK, Australian and New Zealand expertise, to identify desirable amendments. The aim was to improve rater experience by removing ambiguity and inconsistency in the glossary rather than more radical revision. Changes proposed to the HoNOS are reported. HoNOS 65+ changes will be reported separately. Based on the views and experience of the countries involved, a series of amendments were identified. Clinical implications While effective clinician training remains critically important, these revisions aim to improve intra- and interrater reliability and improve validity. Next steps will depend on feedback from HoNOS users. Reliability and validity testing will depend on funding. Declaration of interest None.

  17. Evidence-Based School Behavior Assessment of Externalizing Behavior in Young Children.

    PubMed

    Bagner, Daniel M; Boggs, Stephen R; Eyberg, Sheila M

    2010-02-01

    This study examined the psychometric properties of the Revised Edition of the School Observation Coding System (REDSOCS). Participants were 68 children ages 3 to 6 who completed parent-child interaction therapy for Oppositional Defiant Disorder as part of a larger efficacy trial. Interobserver reliability on REDSOCS categories was moderate to high, with percent agreement ranging from 47% to 90% (M = 67%) and Cohen's kappa coefficients ranging from .69 to .95 (M = .82). Convergent validity of the REDSOCS categories was supported by significant correlations with the Intensity Scale of the Sutter-Eyberg Student Behavior Inventory-Revised and related subscales of the Conners' Teacher Rating Scale-Revised: Long Version (CTRS-R: L). Divergent validity was indicated by nonsignificant correlations between REDSOCS categories and scales on the CTRS-R: L expected not to relate to disruptive classroom behavior. Treatment sensitivity was demonstrated for two of the three primary REDSOCS categories by significant pre to posttreatment changes. This study provides psychometric support for the designation of REDSOCS as an evidence-based assessment procedure for young children.

  18. Estimation of Critical Gap Based on Raff's Definition

    PubMed Central

    Guo, Rui-jun; Wang, Xiao-jing; Wang, Wan-xiang

    2014-01-01

    Critical gap is an important parameter used to calculate the capacity and delay of minor road in gap acceptance theory of unsignalized intersections. At an unsignalized intersection with two one-way traffic flows, it is assumed that two events are independent between vehicles' arrival of major stream and vehicles' arrival of minor stream. The headways of major stream follow M3 distribution. Based on Raff's definition of critical gap, two calculation models are derived, which are named M3 definition model and revised Raff's model. Both models use total rejected coefficient. Different calculation models are compared by simulation and new models are found to be valid. The conclusion reveals that M3 definition model is simple and valid. Revised Raff's model strictly obeys the definition of Raff's critical gap and its application field is more extensive than Raff's model. It can get a more accurate result than the former Raff's model. The M3 definition model and revised Raff's model can derive accordant result. PMID:25574160

  19. Estimation of critical gap based on Raff's definition.

    PubMed

    Guo, Rui-jun; Wang, Xiao-jing; Wang, Wan-xiang

    2014-01-01

    Critical gap is an important parameter used to calculate the capacity and delay of minor road in gap acceptance theory of unsignalized intersections. At an unsignalized intersection with two one-way traffic flows, it is assumed that two events are independent between vehicles' arrival of major stream and vehicles' arrival of minor stream. The headways of major stream follow M3 distribution. Based on Raff's definition of critical gap, two calculation models are derived, which are named M3 definition model and revised Raff's model. Both models use total rejected coefficient. Different calculation models are compared by simulation and new models are found to be valid. The conclusion reveals that M3 definition model is simple and valid. Revised Raff's model strictly obeys the definition of Raff's critical gap and its application field is more extensive than Raff's model. It can get a more accurate result than the former Raff's model. The M3 definition model and revised Raff's model can derive accordant result.

  20. Semi-Automatic Determination of Rockfall Trajectories

    PubMed Central

    Volkwein, Axel; Klette, Johannes

    2014-01-01

    In determining rockfall trajectories in the field, it is essential to calibrate and validate rockfall simulation software. This contribution presents an in situ device and a complementary Local Positioning System (LPS) that allow the determination of parts of the trajectory. An assembly of sensors (herein called rockfall sensor) is installed in the falling block recording the 3D accelerations and rotational velocities. The LPS automatically calculates the position of the block along the slope over time based on Wi-Fi signals emitted from the rockfall sensor. The velocity of the block over time is determined through post-processing. The setup of the rockfall sensor is presented followed by proposed calibration and validation procedures. The performance of the LPS is evaluated by means of different experiments. The results allow for a quality analysis of both the obtained field data and the usability of the rockfall sensor for future/further applications in the field. PMID:25268916

  1. ISFET pH Sensitivity: Counter-Ions Play a Key Role.

    PubMed

    Parizi, Kokab B; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H S Philip

    2017-02-02

    The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor.

  2. ISFET pH Sensitivity: Counter-Ions Play a Key Role

    PubMed Central

    Parizi, Kokab B.; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H. S. Philip

    2017-01-01

    The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor. PMID:28150700

  3. The Anxiety Sensitivity Index--Revised: Confirmatory Factor Analyses, Structural Invariance in Caucasian and African American Samples, and Score Reliability and Validity

    ERIC Educational Resources Information Center

    Arnau, Randolph C.; Broman-Fulks, Joshua J.; Green, Bradley A.; Berman, Mitchell E.

    2009-01-01

    The most commonly used measure of anxiety sensitivity is the 36-item Anxiety Sensitivity Index--Revised (ASI-R). Exploratory factor analyses have produced several different factors structures for the ASI-R, but an acceptable fit using confirmatory factor analytic approaches has only been found for a 21-item version of the instrument. We evaluated…

  4. Psychometric properties of the revised conscientiousness dimension of Inventário Dimensional Clínico da Personalidade (IDCP).

    PubMed

    Carvalho, Lucas de Francisco; Souza, Bruna Daniela Balbino de; Primi, Ricardo

    2014-01-01

    This study investigated the psychometric properties of the revised scale of conscientiousness of a clinical personality inventory (Inventário Dimensional Clínico da Personalidade, IDCP). One hundred and twenty participants (68 women; 56.7%) aged 18 to 53 years (mean = 22.58, standard deviation = 6.19) were recruited by convenience and answered the IDCP and the NEO Personality Inventory - Revised. The analysis of internal structure, association with external variables and reliability of the dimension under review confirmed its validity. The psychometric characteristics of the revised dimension seem to be more adequate than those of the original version and more focused on pathological functioning, which was expected and desirable.

  5. Testing Math or Testing Language? The Construct Validity of the KeyMath-Revised for Children With Intellectual Disability and Language Difficulties.

    PubMed

    Rhodes, Katherine T; Branum-Martin, Lee; Morris, Robin D; Romski, MaryAnn; Sevcik, Rose A

    2015-11-01

    Although it is often assumed that mathematics ability alone predicts mathematics test performance, linguistic demands may also predict achievement. This study examined the role of language in mathematics assessment performance for children with intellectual disability (ID) at less severe levels, on the KeyMath-Revised Inventory (KM-R) with a sample of 264 children, in grades 2-5. Using confirmatory factor analysis, the hypothesis that the KM-R would demonstrate discriminant validity with measures of language abilities in a two-factor model was compared to two plausible alternative models. Results indicated that KM-R did not have discriminant validity with measures of children's language abilities and was a multidimensional test of both mathematics and language abilities for this population of test users. Implications are considered for test development, interpretation, and intervention.

  6. The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R): a scale to assist the diagnosis of Autism Spectrum Disorder in adults: an international validation study.

    PubMed

    Ritvo, Riva Ariella; Ritvo, Edward R; Guthrie, Donald; Ritvo, Max J; Hufnagel, Demetra H; McMahon, William; Tonge, Bruce; Mataix-Cols, David; Jassi, Amita; Attwood, Tony; Eloff, Johann

    2011-08-01

    The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R) is a valid and reliable instrument to assist the diagnosis of adults with Autism Spectrum Disorders (ASD). The 80-question scale was administered to 779 subjects (201 ASD and 578 comparisons). All ASD subjects met inclusion criteria: DSM-IV-TR, ADI/ADOS diagnoses and standardized IQ testing. Mean scores for each of the questions and total mean ASD vs. the comparison groups' scores were significantly different (p < .0001). Concurrent validity with Constantino Social Responsiveness Scale-Adult = 95.59%. Sensitivity = 97%, specificity = 100%, test-retest reliability r = .987. Cronbach alpha coefficients for the subscales and 4 derived factors were good. We conclude that the RAADS-R is a useful adjunct diagnostic tool for adults with ASD.

  7. Validation of the self-assessment teamwork tool (SATT) in a cohort of nursing and medical students.

    PubMed

    Roper, Lucinda; Shulruf, Boaz; Jorm, Christine; Currie, Jane; Gordon, Christopher J

    2018-02-09

    Poor teamwork has been implicated in medical error and teamwork training has been shown to improve patient care. Simulation is an effective educational method for teamwork training. Post-simulation reflection aims to promote learning and we have previously developed a self-assessment teamwork tool (SATT) for health students to measure teamwork performance. This study aimed to evaluate the psychometric properties of a revised self-assessment teamwork tool. The tool was tested in 257 medical and nursing students after their participation in one of several mass casualty simulations. Using exploratory and confirmatory factor analysis, the revised self-assessment teamwork tool was shown to have strong construct validity, high reliability, and the construct demonstrated invariance across groups (Medicine & Nursing). The modified SATT was shown to be a reliable and valid student self-assessment tool. The SATT is a quick and practical method of guiding students' reflection on important teamwork skills.

  8. California Diploma Project Technical Report III: Validity Study--Validity Study of the Health Sciences and Medical Technology Standards

    ERIC Educational Resources Information Center

    McGaughy, Charis; Bryck, Rick; de Gonzalez, Alicia

    2012-01-01

    This study is a validity study of the recently revised version of the Health Science Standards. The purpose of this study is to understand how the Health Science Standards relate to college and career readiness, as represented by survey ratings submitted by entry-level college instructors of health science courses and industry representatives. For…

  9. Initial design and performance of the near surface unmanned aircraft system sensor suite in support of the GOES-R field campaign

    NASA Astrophysics Data System (ADS)

    Pearlman, Aaron J.; Padula, Francis; Shao, Xi; Cao, Changyong; Goodman, Steven J.

    2016-09-01

    One of the main objectives of the Geostationary Operational Environmental Satellite R-Series (GOES-R) field campaign is to validate the SI traceability of the Advanced Baseline Imager. The campaign plans include a feasibility demonstration study for new near surface unmanned aircraft system (UAS) measurement capability that is being developed to meet the challenges of validating geostationary sensors. We report our progress in developing our initial systems by presenting the design and preliminary characterization results of the sensor suite. The design takes advantage of off-the-shelf technologies and fiber-based optical components to make hemispheric directional measurements from a UAS. The characterization results - including laboratory measurements of temperature effects and polarization sensitivity - are used to refine the radiometric uncertainty budget towards meeting the validation objectives for the campaign. These systems will foster improved validation capabilities for the GOES-R field campaign and other next generation satellite systems.

  10. EUDAT strategies for handling dynamic data in the solid Earth Sciences

    NASA Astrophysics Data System (ADS)

    Michelini, Alberto; Evans, Peter; Kemps-Snijder, Mark; Heikkinen, Jani; Buck, Justin; Misutka, Jozef; Drude, Sebastian; Fares, Massimo; Cacciari, Claudio; Fiameni, Giuseppe

    2014-05-01

    Some dynamic data is generated by sensors which produce data streams that may be temporarily incomplete (owing to latencies or temporary interruptions of the transmission lines between the field sensors and the data acquisition centres) and that may consequently fill up over time (automatically or after manual intervention). Dynamic data can also be generated by massive crowd sourcing where, for example, experimental collections of data can be filled up at random moments. The nature of dynamic data makes it difficult to handle for various reasons: a) establishing valid policies that guide early replication for data preservation and access optimization is not trivial, b) identifying versions of such data - thus making it possible to check their integrity - and referencing the versions is also a challenging task, and c) performance issues are extremely important since all these activities must be performed fast enough to keep up with the incoming data stream. There is no doubt that both applications areas (namely data from sensors and crowdsourcing) are growing in their relevance for science, and that appropriate infrastructure support (by initiatives such as EUDAT) is vital to handle these challenges. In addition, data must be citeable to encourage transparent, reproducible science, and to provide clear metrics for assessing the impact of research, which also drives funding choices. Data stream in real time often undergo changes/revisions while they are still growing, as new data arrives, and they are revised as missing data is recovered, or as new calibration values are applied. We call these "dynamic" data sets, DDS. A common form of DDS is time series data in which measurements are obtained on a regular schedule, with a well-defined sample rate. Examples include the hourly temperature in Barcelona, and the displacement (a 3-D vector quantity) of a seismograph from its rest position, which may record at a rate of 100 or more samples per second. These form streams of data, and a complete data set may contain many streams. It is important to distinguish between "observation time" (or measurement time, MT), at which a measurement is made and "access time" (or state time, ST, or ingestion time), at which data arrived in this database system. Granularity in time is the third ingredient and it mainly refers to reproducibility: is there a requirement to distinguish between states a few seconds, minutes, days apart? This time may be as small as the time between successive samples. Granularity relates to accountability. We present a possible solution which stems on representing each observation in a dynamic data stream by a point in the bi-temporal space defined by (MT, ST) corresponding to the time at which the data arrived and the time to which it refers. Features of dynamic data such as latency and gaps can then be visualised: delays in arrival of the data (latency) move observations down from the line labelled "real time", while missing values (gaps) cause the sequence of observations to jump to the right. Revisions of values at one or more time appear below the original values.

  11. External Validation of the HERNIAscore: An Observational Study.

    PubMed

    Cherla, Deepa V; Moses, Maya L; Mueck, Krislynn M; Hannon, Craig; Ko, Tien C; Kao, Lillian S; Liang, Mike K

    2017-09-01

    The HERNIAscore is a ventral incisional hernia (VIH) risk assessment tool that uses only preoperative variables and predictable intraoperative variables. The aim of this study was to validate and modify, if needed, the HERNIAscore in an external dataset. This was a retrospective observational study of all patients undergoing resection for gastrointestinal malignancy from 2011 through 2015 at a safety-net hospital. The primary end point was clinical postoperative VIH. Patients were stratified into low-risk, medium-risk, and high-risk groups based on HERNIAscore. A revised HERNIAscore was calculated with the addition of earlier abdominal operation as a categorical variable. Cox regression of incisional hernia with stratification by risk class was performed. Incidence rates of clinical VIH formation within each risk class were also calculated. Two hundred and forty-seven patents were enrolled. On Cox regression, in addition to the 3 variables of the HERNIAscore (BMI, COPD, and incision length), earlier abdominal operation was also predictive of VIH. The revised HERNIAscore demonstrated improved predictive accuracy for clinical VIH. Although the original HERNIAscore effectively stratified the risk of an incisional radiographic VIH developing, the revised HERNIAscore provided a statistically significant stratification for both clinical and radiographic VIHs in this patient cohort. We have externally validated and improved the HERNIAscore. The revised HERNIAscore uses BMI, incision length, COPD, and earlier abdominal operation to predict risk of postoperative incisional hernia. Future research should assess methods to prevent incisional hernias in moderate-to-high risk patients. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Validity of Self-Reported Concentration and Memory Problems: Relationship with Neuropsychological Assessment and Depression

    EPA Science Inventory

    Background: This study investigated the validity of self-reported concentration and memory problems (CMP) in residents environmentally exposed to manganese (Mn). Method: Self-report of CMP from a health questionnaire (HQ) and the Symptoms Checklist-90-Revised (SCL-90-R) was com...

  13. Identifying Sources of Bias in the WISC-R.

    ERIC Educational Resources Information Center

    Vance, Booney; Sabatino, David

    1991-01-01

    The issues of construct validity, predictive validity, and item content bias on the Wechsler Intelligence Scale for Children-Revised (WISC-R) are examined. The review concludes that most objective data have not supported the issue of bias of the WISC-R when used with children of different ethnic backgrounds. (JDD)

  14. Validity of Random Short Forms: III. Wechsler's Intelligence Scales.

    ERIC Educational Resources Information Center

    Silverstein, A. B.

    1983-01-01

    Formulas for estimating the validity of random short forms were applied to the standardization data for the Wechsler Adult Intelligence Scale-Revised, the Minnesota Multiphasic Personality Inventory, and the Marlowe-Crowne Social Desirability Scale. These formulas demonstrated how much "better than random" the best short forms of these…

  15. 76 FR 22308 - Airworthiness Directives; Airbus Model A340-541 and -642 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-21

    ... airworthiness information (MCAI) originated by an aviation authority of another country to identify and correct... PB201 were de-validated starting from the SRM revision issued on January 2009. The terminology ``De... ``de-validated SRM'' repairs and, if necessary, to apply the associated corrective actions [repair...

  16. Chemical Sensor Array Response Modeling Using Quantitative Structure-Activity Relationships Technique

    NASA Astrophysics Data System (ADS)

    Shevade, Abhijit V.; Ryan, Margaret A.; Homer, Margie L.; Zhou, Hanying; Manfreda, Allison M.; Lara, Liana M.; Yen, Shiao-Pin S.; Jewell, April D.; Manatt, Kenneth S.; Kisor, Adam K.

    We have developed a Quantitative Structure-Activity Relationships (QSAR) based approach to correlate the response of chemical sensors in an array with molecular descriptors. A novel molecular descriptor set has been developed; this set combines descriptors of sensing film-analyte interactions, representing sensor response, with a basic analyte descriptor set commonly used in QSAR studies. The descriptors are obtained using a combination of molecular modeling tools and empirical and semi-empirical Quantitative Structure-Property Relationships (QSPR) methods. The sensors under investigation are polymer-carbon sensing films which have been exposed to analyte vapors at parts-per-million (ppm) concentrations; response is measured as change in film resistance. Statistically validated QSAR models have been developed using Genetic Function Approximations (GFA) for a sensor array for a given training data set. The applicability of the sensor response models has been tested by using it to predict the sensor activities for test analytes not considered in the training set for the model development. The validated QSAR sensor response models show good predictive ability. The QSAR approach is a promising computational tool for sensing materials evaluation and selection. It can also be used to predict response of an existing sensing film to new target analytes.

  17. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    PubMed

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  18. The Content Validity of a Chemotherapy-Induced Peripheral Neuropathy Patient-Reported Outcome Measure

    PubMed Central

    Lavoie Smith, Ellen M.; Haupt, Rylie; Kelly, James P.; Lee, Deborah; Kanzawa-Lee, Grace; Knoerl, Robert; Bridges, Celia; Alberti, Paola; Prasertsri, Nusara; Donohoe, Clare

    2018-01-01

    Purpose/Objectives To test the content validity of a 16-item version of the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire–Chemotherapy-Induced Peripheral Neuropathy (QLQ-CIPN20). Research Approach Cross-sectional, prospective, qualitative design. Setting Six outpatient oncology clinics within the University of Michigan Health System’s comprehensive cancer center in Ann Arbor. Participants 25 adults with multiple myeloma or breast, gynecologic, gastrointestinal, or head and neck malignancies experiencing peripheral neuropathy caused by neurotoxic chemotherapy. Methodologic Approach Cognitive interviewing methodology was used to evaluate the content validity of a 16-item version of the QLQ-CIPN20 instrument. Findings Minor changes were made to three questions to enhance readability. Twelve questions were revised to define unfamiliar terminology, clarify the location of neuropathy, and emphasize important aspects. One question was deleted because of clinical and conceptual redundancy with other items, as well as concerns regarding generalizability and social desirability. Interpretation Cognitive interviewing methodology revealed inconsistencies between patients’ understanding and researchers’ intent, along with points that required clarification to avoid misunderstanding. Implications for Nursing Patients’ interpretations of the instrument’s items were inconsistent with the intended meanings of the questions. One item was dropped and others were revised, resulting in greater consistency in how patients, clinicians, and researchers interpreted the items’ meanings and improving the instrument’s content validity. Following additional revision and psychometric testing, the QLQ-CIPN20 could evolve into a gold-standard CIPN patient-reported outcome measure. PMID:28820525

  19. Patient perspective on quality of geriatric care and rehabilitation--development and psychometric testing of a questionnaire.

    PubMed

    Wressle, Ewa; Eriksson, Lennart; Fahlander, Amie; Rasmusson, Ing-Marie; Tedemalm, Ulla; Tängmark, Karin

    2006-06-01

    The aim was to develop and test a questionnaire for use in telephone interviews concerning patient evaluation of geriatric care and rehabilitation. Instrument development was performed comprising qualitative interviews, construction of items, content validation, pilot study and data collection for evaluation of care and rehabilitation, clinical utility, reliability and construct validity. Qualitative interviews were performed with 12 elderly participants. The qualitative interviews formed the basis for the construction of 45 items. An expert panel performed a content validation of the questionnaire resulting in a revised version. A pilot study comprised 29 participants recently discharged from geriatric wards and the main data collection comprised 221 participants. Inclusion criteria were being able to perform a telephone interview and willingness to participate. Clinical utility was examined through questions to the interviewers, answered in writing. Cronbach's alpha coefficient was 0.79. According to a factor analysis and the evaluation of clinical utility, the underlying dimensions of the final revised questionnaire concern 'Respect and safety', 'Information and participation' and 'Rehabilitation interventions', scored in 18 items. In addition, one global item concerns satisfaction with care, resulting in 19 items in total. The revised questionnaire was named PaPeR, Patient Perspective on care and Rehabilitation. The questionnaire is considered valid, reliable and judged to have good clinical utility. The time consumption for the telephone interview is about 10-20 minutes. The questionnaire is useful in defining areas for potential quality improvement in geriatric wards.

  20. A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement.

    PubMed

    Jia, Dagong; Chao, Jing; Li, Shuai; Zhang, Hongxia; Yan, Yingzhan; Liu, Tiegen; Sun, Ye

    2018-04-01

    In this paper, we report the design and experimental validation of a novel optical sensor for radial artery pulse measurement based on fiber Bragg grating (FBG) and lever amplification mechanism. Pulse waveform analysis is a diagnostic tool for clinical examination and disease diagnosis. High fidelity radial artery pulse waveform has been investigated in clinical studies for estimating central aortic pressure, which is proved to be predictors of cardiovascular diseases. As a three-dimensional cylinder, the radial artery needs to be examined from different locations to achieve optimal pulse waveform for estimation and diagnosis. The proposed optical sensing system is featured as high sensitivity and immunity to electromagnetic interference for multilocation radial artery pulse waveform measurement. The FBG sensor can achieve the sensitivity of 8.236 nm/N, which is comparable to a commonly used electrical sensor. This FBG-based system can provide high accurate measurement, and the key characteristic parameters can be then extracted from the raw signals for clinical applications. The detecting performance is validated through experiments guided by physicians. In the experimental validation, we applied this sensor to measure the pulse waveforms at various positions and depths of the radial artery in the wrist according to the diagnostic requirements. The results demonstrate the high feasibility of using optical systems for physiological measurement and using this FBG sensor for radial artery pulse waveform in clinical applications.

  1. Taxonomic and systematic revisions to the North American Nimravidae (Mammalia, Carnivora)

    PubMed Central

    2016-01-01

    The Nimravidae is a family of extinct carnivores commonly referred to as “false saber-tooth cats.” Since their initial discovery, they have prompted difficulty in taxonomic assignments and number of valid species. Past revisions have only examined a handful of genera, while recent advances in cladistic and morphometric analyses have granted us additional avenues to answering questions regarding our understanding of valid nimravid taxa and their phylogenetic relationships. To resolve issues of specific validity, the phylogenetic species concept (PSC) was utilized to maintain consistency in diagnosing valid species, while simultaneously employing character and linear morphometric analyses for confirming the validity of taxa. Determined valid species and taxonomically informative characters were then employed in two differential cladistic analyses to create competing hypotheses of interspecific relationships. The results suggest the validity of twelve species and six monophyletic genera. The first in depth reviews of Pogonodon and Dinictis returned two valid species (P. platycopis, P. davisi) for the former, while only one for the latter (D. felina). The taxonomic validity of Nanosmilus is upheld. Two main clades with substantial support were returned for all cladistic analyses, the Hoplophoneini and Nimravini, with ambiguous positions relative to these main clades for the European taxa: Eofelis, Dinailurictis bonali, and Quercylurus major; and the North American taxa Dinictis and Pogonodon. Eusmilus is determined to represent a non-valid genus for North American taxa, suggesting non-validity for Old World nimravid species as well. Finally, Hoplophoneus mentalis is found to be a junior synonym of Hoplophoneus primaevus, while the validity of Hoplophoneus oharrai is reinstated. PMID:26893959

  2. Freezing of gait and fall detection in Parkinson's disease using wearable sensors: a systematic review.

    PubMed

    Silva de Lima, Ana Lígia; Evers, Luc J W; Hahn, Tim; Bataille, Lauren; Hamilton, Jamie L; Little, Max A; Okuma, Yasuyuki; Bloem, Bastiaan R; Faber, Marjan J

    2017-08-01

    Despite the large number of studies that have investigated the use of wearable sensors to detect gait disturbances such as Freezing of gait (FOG) and falls, there is little consensus regarding appropriate methodologies for how to optimally apply such devices. Here, an overview of the use of wearable systems to assess FOG and falls in Parkinson's disease (PD) and validation performance is presented. A systematic search in the PubMed and Web of Science databases was performed using a group of concept key words. The final search was performed in January 2017, and articles were selected based upon a set of eligibility criteria. In total, 27 articles were selected. Of those, 23 related to FOG and 4 to falls. FOG studies were performed in either laboratory or home settings, with sample sizes ranging from 1 PD up to 48 PD presenting Hoehn and Yahr stage from 2 to 4. The shin was the most common sensor location and accelerometer was the most frequently used sensor type. Validity measures ranged from 73-100% for sensitivity and 67-100% for specificity. Falls and fall risk studies were all home-based, including samples sizes of 1 PD up to 107 PD, mostly using one sensor containing accelerometers, worn at various body locations. Despite the promising validation initiatives reported in these studies, they were all performed in relatively small sample sizes, and there was a significant variability in outcomes measured and results reported. Given these limitations, the validation of sensor-derived assessments of PD features would benefit from more focused research efforts, increased collaboration among researchers, aligning data collection protocols, and sharing data sets.

  3. Lessons learned in Liberia: preliminary examination of the psychometric properties of trust and teamwork among maternal healthcare workers.

    PubMed

    Lori, Jody R; Munro, Michelle L; Moore, Jennifer E; Fladger, Jessica

    2013-04-11

    Post-conflict Liberia has one of the fastest growing populations on the continent and one of the highest maternal mortality rates among the world. However, in the rural regions, less than half of all births are attended by a skilled birth attendant. There is a need to evaluate the relationship between trained traditional healthcare providers and skilled birth attendants to improve maternal health outcomes. This evaluation must also take into consideration the needs and desires of the patients. The purpose of this pilot study was to establish the validity and reliability of a survey tool to evaluate trust and teamwork in the working relationships between trained traditional midwives and certified midwives in a post-conflict country. A previously established scale, the Trust and Teambuilding Scale, was used with non- and low-literate trained traditional midwives (n=48) in rural Liberia to evaluate trust and teamwork with certified midwives in their communities. Initial results indicated that the scale and response keys were culturally inadequate for this population. A revised version of the scale, the Trust and Teamwork Scale - Liberia, was created and administered to an additional group of non- and low-literate, trained traditional midwives (n=42). Exploratory factor analysis using Mplus for dichotomous variables was used to determine the psychometric properties of the revised scale and was then confirmed with the full sample (n=90). Additional analyses included contrast validity, convergent validity, and Kuder-Richardson reliability. Exploratory factor analysis revealed two factors in the revised Trust and Teamwork Scale - Liberia. These two factors, labeled trust and teamwork, included eleven of the original eighteen items used in the Trust and Teamwork Scale and demonstrated contrast and convergent validity and adequate reliability. The revised scale is suitable for use with non- and low-literate, trained traditional midwives in rural Liberia. Continued cross-cultural validation of tools is essential to ensure scale adequacy across populations. Future work should continue to evaluate the use of the Trust and Teamwork Scale - Liberia across cultures and additional work is needed to confirm the factor structure.

  4. Select Methodology for Validating Advanced Satellite Measurement Systems

    NASA Technical Reports Server (NTRS)

    Larar, Allen M.; Zhou, Daniel K.; Liu, Xi; Smith, William L.

    2008-01-01

    Advanced satellite sensors are tasked with improving global measurements of the Earth's atmosphere, clouds, and surface to enable enhancements in weather prediction, climate monitoring capability, and environmental change detection. Measurement system validation is crucial to achieving this goal and maximizing research and operational utility of resultant data. Field campaigns including satellite under-flights with well calibrated FTS sensors aboard high-altitude aircraft are an essential part of the validation task. This presentation focuses on an overview of validation methodology developed for assessment of high spectral resolution infrared systems, and includes results of preliminary studies performed to investigate the performance of the Infrared Atmospheric Sounding Interferometer (IASI) instrument aboard the MetOp-A satellite.

  5. Sensitivity Study for Sensor Optical and Electric Crosstalk Based on Spectral Measurements: An Application to Developmental Sensors Using Heritage Sensors Such As MODIS

    NASA Technical Reports Server (NTRS)

    Butler, James J.; Oudrari, Hassan; Xiong, Sanxiong; Che, Nianzeng; Xiong, Xiaoxiong

    2007-01-01

    The process of developing new sensors for space flight frequently builds upon the designs and experience of existing heritage space flight sensors. Frequently in the development and testing of new sensors, problems are encountered that pose the risk of serious impact on successful retrieval of geophysical products. This paper describes an approach to assess the importance of optical and electronic cross-talk on retrieval of geophysical products using new MODIS-like sensors through the use of MODIS data sets. These approaches may be extended to any sensor characteristic and any sensor where that characteristic may impact the Level 1 products so long as validated geophysical products are being developed from the heritage sensor. In this study, a set of electronic and/or optical cross-talk coefficients are postulated. These coefficients are sender-receiver influence coefficients and represent a sensor signal contamination on any detector on a focal plane when another band's detectors on that focal plane are stimulated with a monochromatic light. The approach involves using the postulated cross-talk coefficients on an actual set of MODIS data granules. The original MODIS data granules and the cross-talk impacted granules are used with validated geophysical algorithms to create the derived products. Comparison of the products produced with the original and cross-talk impacted granules indicates potential problems, if any, with the characteristics of the developmental sensor that are being studied.

  6. Load monitoring using a calibrated piezo diaphragm based impedance strain sensor and wireless sensor network in real time

    NASA Astrophysics Data System (ADS)

    Gopal Madhav Annamdas, Venu; Kiong Soh, Chee

    2017-04-01

    The last decade has seen the use of various wired-wireless and contact-contactless sensors in several structural health monitoring (SHM) techniques. Most SHM sensors that are predominantly used for strain measurements may be ineffective for damage detection and vice versa, indicating the uniapplicability of these sensors. However, piezoelectric (PE)-based macro fiber composite (MFC) and lead zirconium titanate (PZT) sensors have been on the rise in SHM, vibration and damping control, etc, due to their superior actuation and sensing abilities. These PE sensors have created much interest for their multi-applicability in various technologies such as electromechanical impedance (EMI)-based SHM. This research employs piezo diaphragms, a cheaper alternative to several expensive types of PZT/MFC sensors for the EMI technique. These piezo diaphragms were validated last year for their applicability in damage detection using the frequency domain. Here we further validate their applicability in strain monitoring using the real time domain. Hence, these piezo diaphragms can now be classified as PE sensors and used with PZT and MFC sensors in the EMI technique for monitoring damage and loading. However, no single technique or single type of sensor will be sufficient for large SHM, thus requiring the necessary deployment of more than one technique with different types of sensors such as a piezoresistive strain gauge based wireless sensor network for strain measurements to complement the EMI technique. Furthermore, we present a novel procedure of converting a regular PE sensor in the ‘frequency domain’ to ‘real time domain’ for strain applications.

  7. Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Bramlage, Peter; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Zwingers, Thomas; Beime, Beate; Mengden, Thomas

    2014-01-01

    The aim of the present study was to validate the custo screen 400 ambulatory blood pressure-monitoring (ABPM) device according to the 2010 International Protocol revision of the European Society of Hypertension (ESH-IP). The device can be used for ABPM for up to 72 hours. Systolic and diastolic blood pressure (SBP and DBP, respectively) were sequentially measured in 33 adult subjects (13 males and 20 females) and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The custo screen 400 met the requirements of parts 1 and 2 of the ESH-IP revision 2010. The mean difference between the device and reference sphygmomanometer readings was -0.5±4.5 mmHg for SBP and -0.1±3.3 mmHg for DBP. All but one measurement were within the absolute difference of 10 mmHg between the device and the observers for SBP and DBP. The number of absolute differences between the device and the observers within a range of 5 mmHg was 84 of 99 readings for SBP, and 93 of 99 readings for DBP. The custo screen 400 ABPM device met the requirements of the 2010 ESH-IP revision, and hence can be recommended for ABPM in adults. To our knowledge, the custo screen 400 is the first device to pass the revised ESH-IP 2010.

  8. Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010

    PubMed Central

    Bramlage, Peter; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Zwingers, Thomas; Beime, Beate; Mengden, Thomas

    2014-01-01

    Objective The aim of the present study was to validate the custo screen 400 ambulatory blood pressure-monitoring (ABPM) device according to the 2010 International Protocol revision of the European Society of Hypertension (ESH-IP). The device can be used for ABPM for up to 72 hours. Materials and methods Systolic and diastolic blood pressure (SBP and DBP, respectively) were sequentially measured in 33 adult subjects (13 males and 20 females) and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. Results The custo screen 400 met the requirements of parts 1 and 2 of the ESH-IP revision 2010. The mean difference between the device and reference sphygmomanometer readings was −0.5±4.5 mmHg for SBP and −0.1±3.3 mmHg for DBP. All but one measurement were within the absolute difference of 10 mmHg between the device and the observers for SBP and DBP. The number of absolute differences between the device and the observers within a range of 5 mmHg was 84 of 99 readings for SBP, and 93 of 99 readings for DBP. Conclusion The custo screen 400 ABPM device met the requirements of the 2010 ESH-IP revision, and hence can be recommended for ABPM in adults. To our knowledge, the custo screen 400 is the first device to pass the revised ESH-IP 2010. PMID:24868162

  9. Psychometric properties of the revised Malay version Medical Outcome Study Social Support Survey using confirmatory factor analysis among postpartum mothers.

    PubMed

    Norhayati, Mohd Noor; Aniza, Abd Aziz; Nik Hazlina, Nik Hussain; Azman, Mohd Yacob

    2015-12-01

    Social support is an essential component for the physical and emotional well-being of postpartum mothers. The objective of this study is to determine the psychometric properties of the revised Malay version Medical Outcome Study (MOS) Social Support Survey using a confirmatory validity approach. A cross-sectional study was conducted involving 144 postpartum mothers attending Obstetric and Gynecology Clinic, Universiti Sains Malaysia Hospital. Construct validity and internal consistency assessment was performed after the translation, content validity and face validity process. The data were analyzed using SPSS 20.0 (SPSS Inc., Chicago, IL, USA) and AMOS 20.0 (SPSS Inc., Chicago, IL, USA). The original questionnaire consists of four domains (emotional/informational support, tangible support, affectionate support and positive social interaction) and 19 items. Affectionate support domain with three items only was treated as a separate construct and was not included in the factor analysis. The final confirmatory model with three constructs and 13 items demonstrated acceptable factor loadings, domain to domain correlation and best fit; (χ2[df]=1.665 [61]; P-value=0.001; Tucker-Lewis Index=0.944; comparative fit index=0.956; root mean square error of approximation=0.068). Composite reliability, average variance extracted and Cronbach's α of the domains ranged from 0.649 to 0.903; 0.390 to 0.699; 0.616 to 0.902, respectively. The study suggested that the four-factor model with 16 items (including one separate factor of affectionate) of the revised Malay version MOS Social Support Survey was acceptable to be used to measure social support after childbirth because it is valid, reliable and simple. © 2015 Wiley Publishing Asia Pty Ltd.

  10. 2016 Revisions to the 2010/2011 fibromyalgia diagnostic criteria.

    PubMed

    Wolfe, Frederick; Clauw, Daniel J; Fitzcharles, Mary-Ann; Goldenberg, Don L; Häuser, Winfried; Katz, Robert L; Mease, Philip J; Russell, Anthony S; Russell, Irwin Jon; Walitt, Brian

    2016-12-01

    The provisional criteria of the American College of Rheumatology (ACR) 2010 and the 2011 self-report modification for survey and clinical research are widely used for fibromyalgia diagnosis. To determine the validity, usefulness, potential problems, and modifications required for the criteria, we assessed multiple research reports published in 2010-2016 in order to provide a 2016 update to the criteria. We reviewed 14 validation studies that compared 2010/2011 criteria with ACR 1990 classification and clinical criteria, as well as epidemiology, clinical, and databank studies that addressed important criteria-level variables. Based on definitional differences between 1990 and 2010/2011 criteria, we interpreted 85% sensitivity and 90% specificity as excellent agreement. Against 1990 and clinical criteria, the median sensitivity and specificity of the 2010/2011 criteria were 86% and 90%, respectively. The 2010/2011 criteria led to misclassification when applied to regional pain syndromes, but when a modified widespread pain criterion (the "generalized pain criterion") was added misclassification was eliminated. Based on the above data and clinic usage data, we developed a (2016) revision to the 2010/2011 fibromyalgia criteria. Fibromyalgia may now be diagnosed in adults when all of the following criteria are met: CONCLUSIONS: The fibromyalgia criteria have good sensitivity and specificity. This revision combines physician and questionnaire criteria, minimizes misclassification of regional pain disorders, and eliminates the previously confusing recommendation regarding diagnostic exclusions. The physician-based criteria are valid for individual patient diagnosis. The self-report version of the criteria is not valid for clinical diagnosis in individual patients but is valid for research studies. These changes allow the criteria to function as diagnostic criteria, while still being useful for classification. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension.

    PubMed

    Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Ibanez, Isabel; Khabouth, Jose; Khawaja, Salwa; Beaino, Layale; Asmar, Roland

    2011-01-01

    Four oscillometric devices for self-measurement of blood pressure (SBPM) were evaluated according to the European Society of Hypertension (ESH) international protocol and its 2010 revision in four separate studies. The Omron® M2, Omron M3, and Omron M6 measure blood pressure (BP) at the brachial level, while the Omron R2 measures BP at the wrist level. The international protocol requires a total number of 33 subjects in which the validation is performed. The Omron M2 and Omron R2 were validated in 2009 according to the ESH international protocol, while the Omron M3 and Omron M6 were validated in 2010-2011 according to the 2010 ESH international protocol revision. The protocol procedures were followed precisely. All four tested devices passed the validation process. The mean differences between the device and mercury readings were 2.7 ± 5.0 and -1.4 ± 3.2 mmHg for systolic and diastolic BP, respectively, using the Omron M2 device, and 1.7 ± 3.2 and -0.9 ± 2.6 mmHg using the Omron M3, 1.6 ± 2.9 and -0.9 ± 2.5 mmHg using the Omron M6, and -1.1 ± 4.8 and -0.9 ± 4.3 mmHg using the Omron R2. Readings from the Omron M2, Omron M3, Omron M6, and Omron R2, differing by less than 5, 10, and 15 mmHg, fulfill the ESH international protocol and its 2010 revision requirements. Therefore, each of these four devices can be used by patients for SBPM.

  12. On-orbit stability and performance of the Clouds and Earth's Radiant Energy System (CERES) instrument sensors onboard the Aqua and Terra Spacecraft

    NASA Astrophysics Data System (ADS)

    Shankar, Mohan; Priestley, Kory; Smith, Nitchie; Thomas, Susan; Walikainen, Dale

    2014-09-01

    The Clouds and Earth's Radiant Energy System (CERES) instruments onboard the Terra and Aqua spacecraft are part of the NASA Earth Observing System (EOS) constellation to make long-term observations of the earth. CERES measures the earth-reflected shortwave energy as well as the earth-emitted thermal energy, which are two components of the earth's radiation energy budget. These measurements are made by five instruments- Flight Models (FM) 1 and 2 onboard Terra, FMs 3 and 4 onboard Aqua and FM5 onboard Suomi NPP. Each instrument comprises three sensors that measure the radiances in different wavelength bands- a shortwave sensor that measures in the 0.3 to 5 micron band, a total sensor that measures all the incident energy (0.3-200 microns) and a window sensor that measures the water-vapor window region of 8 to 12 microns. The stability of the sensors is monitored through on-orbit calibration and validation activities. On-orbit calibration is carried out using the Internal Calibration Module (ICM) that consists of a tungsten lamp, blackbodies, and a solar diffuser known as the Mirror Attenuator Mosaic (MAM). The ICM calibration provides information about the stability of the sensors' broadband radiometric gains on-orbit. Several validation studies are conducted in order to monitor the behavior of the instruments in various spectral bands. The CERES Edition-4 data products for FM1-FM4 incorporate the latest corrections to the sensor responses using the calibration techniques. In this paper, we present the on-orbit performance stability as well as some validation studies used in deriving the CERES Edition-4 data products from all four instruments.

  13. Evaluation of the hooghoudt and kirkham tile drain equations in the soil and water assessment tool to simulate tile flow and nitrate-nitrogen.

    PubMed

    Moriasi, Daniel N; Gowda, Prasanna H; Arnold, Jeffrey G; Mulla, David J; Ale, Srinivasulu; Steiner, Jean L; Tomer, Mark D

    2013-11-01

    Subsurface tile drains in agricultural systems of the midwestern United States are a major contributor of nitrate-N (NO-N) loadings to hypoxic conditions in the Gulf of Mexico. Hydrologic and water quality models, such as the Soil and Water Assessment Tool, are widely used to simulate tile drainage systems. The Hooghoudt and Kirkham tile drain equations in the Soil and Water Assessment Tool have not been rigorously tested for predicting tile flow and the corresponding NO-N losses. In this study, long-term (1983-1996) monitoring plot data from southern Minnesota were used to evaluate the SWAT version 2009 revision 531 (hereafter referred to as SWAT) model for accurately estimating subsurface tile drain flows and associated NO-N losses. A retention parameter adjustment factor was incorporated to account for the effects of tile drainage and slope changes on the computation of surface runoff using the curve number method (hereafter referred to as Revised SWAT). The SWAT and Revised SWAT models were calibrated and validated for tile flow and associated NO-N losses. Results indicated that, on average, Revised SWAT predicted monthly tile flow and associated NO-N losses better than SWAT by 48 and 28%, respectively. For the calibration period, the Revised SWAT model simulated tile flow and NO-N losses within 4 and 1% of the observed data, respectively. For the validation period, it simulated tile flow and NO-N losses within 8 and 2%, respectively, of the observed values. Therefore, the Revised SWAT model is expected to provide more accurate simulation of the effectiveness of tile drainage and NO-N management practices. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  14. The Swedish Version of the Ritvo Autism and Asperger Diagnostic Scale: Revised (RAADS-R). A Validation Study of a Rating Scale for Adults

    ERIC Educational Resources Information Center

    Andersen, Lisa M. J.; Naswall, Katharina; Manouilenko, Irina; Nylander, Lena; Edgar, Johan; Ritvo, Riva Ariella; Ritvo, Edward; Bejerot, Susanne

    2011-01-01

    There is a paucity of diagnostic instruments for adults with autism spectrum disorder (ASD). This study evaluates the psychometric properties of the Swedish version of the Ritvo Autism and Asperger Diagnostic Scale-Revised (RAADS-R), an 80-item self-rating scale designed to assist clinicians diagnosing ASD in adults. It was administered to 75…

  15. The Chinese Version of the Revised Creativity Domain Questionnaire (CDQ-R): First Evidence for Its Factorial Validity and Systematic Association with the Big Five

    ERIC Educational Resources Information Center

    Werner, Christian H.; Tang, Min; Kruse, Joachim; Kaufman, James C.; Spörrle, Matthias

    2014-01-01

    The present study examines the factor structure of a Chinese version of the Revised Creativity Domain Questionnaire (CDQ-R; Kaufman, Waterstreet, Ailaouni, Whitcomb, Roe, & Riggs, 2009) as well as its relation to Big Five personality traits within a Chinese sample (N = 787). Analyses indicate the appropriateness of the Chinese version of the…

  16. Validation of the Pangao PG-800A11 wrist device assessed according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Xie, Peigen; Wang, Yanling; Xu, Xiaoying; Huang, Fei; Pan, Jingru

    2015-04-01

    The objective of this study was to determine the accuracy of the Pangao PG-800A11 wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the protocol of the British Hypertension Society (BHS). The device evaluations were performed in 85 participants, 33 of whom were included according to the ESH-IP revision 2010 and 52 of whom were included on the basis of the requirements of the BHS protocol. The validation procedure and data analysis followed the protocols precisely. The device achieved an A/A grading for the BHS protocol and passed all phases of the ESH-IP revision 2010 protocol. The mean difference ±SD for the ESH and BHS protocols, respectively, was -0.6±4.5 and -0.8±6.2 mmHg for systolic pressure and 1.2±4.6 and -0.5±5.1 mmHg for diastolic pressure. The device maintained its A/A grading throughout the low, medium, and high-pressure ranges. The Pangao PG-800A11 wrist blood pressure monitor passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol in an adult population.

  17. An Assessment of the Validity of the ECERS-R with Implications for Measures of Child Care Quality and Relations to Child Development

    ERIC Educational Resources Information Center

    Gordon, Rachel A.; Fujimoto, Ken; Kaestner, Robert; Korenman, Sanders; Abner, Kristin

    2013-01-01

    The Early Childhood Environment Rating Scale-Revised (ECERS-R) is widely used to associate child care quality with child development, but its validity for this purpose is not well established. We examined the validity of the ECERS-R using the multidimensional Rasch partial credit model (PCM), factor analyses, and regression analyses with data from…

  18. Refinement of Protocols for Measuring the Apparent Optical Properties of Seawater. Chapter 8

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B.; Zibordi, Giuseppe; Berthon, Jean-Francois; Nirek, Andre; Antoine, David

    2003-01-01

    Ocean color satellite missions, like the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) or the Moderate Resolution Imaging Spectroradiometer (MODIS) projects, are tasked with acquiring a global ocean color data set, validating and monitoring the accuracy and quality of the data, processing the radiometric data into geophysical units using a set of atmospheric and bio-optical algorithms, and distributing the final products to the scientific community. The long-standing requirement of the SeaWiFS Project, for example, is to produce spectral water-leaving radiances, LW(lambda), to within 5% absolute (lambda denotes wavelength) and chlorophyll a concentrations to within 35% (Hooker and Esaias 1993), and most ocean color sensors have the same or similar requirements. Although a diverse set of activities are required to ensure the accuracy requirements are met (Hooker and McClain 2000), the perspective here is with field observations. The accurate determination of upper ocean apparent optical properties (AOPs) is essential for the vicarious calibration of ocean color data and the validation of the derived data products, because the sea-truth measurements are used to evaluate the satellite observations (Hooker and McClain 2000). The uncertainties with in situ AOP measurements have various sources: a) the sampling procedures used in the field, including the environmental conditions encountered; b) the absolute characterization of the radiometers in the laboratory; c) the conversion of the light signals to geophysical units in a processing scheme, and d) the stability of the radiometers in the harsh environment they are subjected to during transport and use. Assuming ideal environmental conditions, so this aspect can be neglected, the SeaWiFS ground-truth uncertainty budget can only be satisfied if each uncertainty is on the order of 1-2%, or what is generally referred to as 1% radiometry. In recent years, progress has been made in estimating the magnitude of some of these uncertainties and in defining procedures for minimizing them. For the SeaWiFS Project, the first step was to convene a workshop to draft the SeaWiFS Ocean Optics Protocols (hereafter referred to as the Protocols). The Protocols initially adhered to the Joint Global Ocean Flux Study (JGOFS) sampling procedures (JGOFS 1991) and defined the standards for optical measurements to be used in SeaWiFS calibration and validation activities (Mueller and Austin 1992). Over time, the Protocols were revised (Mueller and Austin 1995), and then recurringly updated on essentially an annual basis (Mueller 2000, 2002, and 2003) as part of the Sensor Inter-comparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) project. 98

  19. Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.

    PubMed

    Kang, Seong Min; Her, Keun; Choi, Seong Wook

    2016-08-25

    In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.

  20. COBE attitude as seen from the FDF

    NASA Technical Reports Server (NTRS)

    Sedlak, J.; Chu, D.; Scheidker, E.

    1990-01-01

    The goal of the Flight Dynamics Facility (FDF) attitude support is twofold: to determine spacecraft attitude and to explain deviations from nominal attitude behavior. Attitude determination often requires resolving contradictions in the sensor observations. This may be accomplished by applying calibration corrections or by revising the observation models. After accounting for all known sources of error, solution accuracy should be limited only by observation and propagation noise. The second half of the goal is to explain why the attitude may not be as originally intended. Reasons for such deviations include sensor or actuator misalignments and control system performance. In these cases, the ability to explain the behavior should, in principle, be limited only by knowledge of the sensor and actuator data and external torques. Documented here are some results obtained to date in support of the Cosmic Background Explorer (COBE). Advantages and shortcomings of the integrated attitude determination/sensor calibration software are discussed. Some preliminary attitude solutions using data from the Diffuse Infrared Background Experiment (DIRBE) instrument are presented and compared to solutions using Sun and Earth sensors. A dynamical model is constructed to illustrate the relative importance of the various sensor imprefections. This model also shows the connection between the high- and low-frequency attitude oscillations.

  1. Experimental Verification of Buffet Calculation Procedure Using Unsteady PSP

    NASA Technical Reports Server (NTRS)

    Panda, Jayanta

    2016-01-01

    Typically a limited number of dynamic pressure sensors are employed to determine the unsteady aerodynamic forces on large, slender aerospace structures. The estimated forces are known to be very sensitive to the number of the dynamic pressure sensors and the details of the integration scheme. This report describes a robust calculation procedure, based on frequency-specific correlation lengths, that is found to produce good estimation of fluctuating forces from a few dynamic pressure sensors. The validation test was conducted on a flat panel, placed on the floor of a wind tunnel, and was subjected to vortex shedding from a rectangular bluff-body. The panel was coated with fast response Pressure Sensitive Paint (PSP), which allowed time-resolved measurements of unsteady pressure fluctuations on a dense grid of spatial points. The first part of the report describes the detail procedure used to analyze the high-speed, PSP camera images. The procedure includes steps to reduce contamination by electronic shot noise, correction for spatial non-uniformities, and lamp brightness variation, and finally conversion of fluctuating light intensity to fluctuating pressure. The latter involved applying calibration constants from a few dynamic pressure sensors placed at selective points on the plate. Excellent comparison in the spectra, coherence and phase, calculated via PSP and dynamic pressure sensors validated the PSP processing steps. The second part of the report describes the buffet validation process, for which the first step was to use pressure histories from all PSP points to determine the "true" force fluctuations. In the next step only a selected number of pixels were chosen as "virtual sensors" and a correlation-length based buffet calculation procedure was applied to determine "modeled" force fluctuations. By progressively decreasing the number of virtual sensors it was observed that the present calculation procedure was able to make a close estimate of the "true" unsteady forces only from four sensors. It is believed that the present work provides the first validation of the buffet calculation procedure which has been used for the development of many space vehicles.

  2. The Student Risk Screening Scale for Early Childhood: An Initial Validation Study

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Oakes, Wendy Peia; Menzies, Holly Mariah; Major, Rebecca; Allegra, Laurie; Powers, Lisa; Schatschneider, Chris

    2015-01-01

    We report findings of two exploratory validation studies of a revised instrument: the "Student Risk Screening Scale for Early Childhood" version (SRSS-EC). The SRSS-EC was modified to reflect characteristics of externalizing and internalizing behaviors manifested by preschool-age children. In Study 1, we explored the reliability of…

  3. Improving the Performance of the Listening Competency Scale: Revision and Validation

    ERIC Educational Resources Information Center

    Mickelson, William T.; Welch, S. A.

    2013-01-01

    Measuring latent traits is central to quantitative listening research and has been the focus of many studies. One such prominent measurement instrument, based on the Wolvin and Coakley (1993) listening taxonomy, was developed by Ford, Wolvin, and Chung (2000). Subsequent validation research (Mickelson & Welch, 2012) called for revisiting and…

  4. Binge Eating Disorder: Reliability and Validity of a New Diagnostic Category.

    ERIC Educational Resources Information Center

    Brody, Michelle L.; And Others

    1994-01-01

    Examined reliability and validity of binge eating disorder (BED), proposed for inclusion in Diagnostic and Statistical Manual of Mental Disorders (DSM), fourth edition. Interrater reliability of BED diagnosis compared favorably with that of most diagnoses in DSM revised third edition. Study comparing obese individuals with and without BED and…

  5. Early Identification System: Year Two. Research Report 80-15.

    ERIC Educational Resources Information Center

    Stennett, R. G.; Earl, L. M.

    During the academic year 1978-79, school teams implemented a newly developed early identification system in all kindergarten and grade one classes in London, Ontario schools. After analysis and revision of the system, the internal consistency and concurrent validity of the process and a test of its short-term predictive validity were investigated.…

  6. The Revision and Validation of the Academic Motivation Scale in China

    ERIC Educational Resources Information Center

    Zhang, Bo; Li, Yi Ming; Li, Jian; Li, Ye; Zhang, Houcan

    2016-01-01

    Self-determination theory (SDT) has contributed greatly to our understanding of human motivation. Based on SDT, the Academic Motivation Scale (AMS) was developed to assess students' motivation to learn. AMS has been successfully applied to the educational context in Western cultures. However, no psychometrically validated version is available in…

  7. The Rorschach Perceptual-Thinking Index (PTI): An Examination of Reliability, Validity, and Diagnostic Efficiency

    ERIC Educational Resources Information Center

    Hilsenroth, Mark J.; Eudell-Simmons, Erin M.; DeFife, Jared A.; Charnas, Jocelyn W.

    2007-01-01

    This study investigates the reliability, validity, and diagnostic efficiency of the Rorschach Perceptual-Thinking Index (PTI) in relation to the accurate identification of psychotic disorder (PTD) patients. The PTI is a revision of the Rorschach Schizophrenia Index (SCZI), designed to achieve several criteria, including an increase in the…

  8. Concurrent Validity of the Psychopathic Personality Inventory with Offender and Community Samples

    ERIC Educational Resources Information Center

    Malterer, Melanie B.; Lilienfeld, Scott O.; Neumann, Craig S.; Newman, Joseph P.

    2010-01-01

    The Psychopathy Checklist-Revised (PCL-R) is a frequently used and well-validated measure of psychopathy but is relatively time-intensive and expensive to administer. The Psychopathic Personality Inventory (PPI) is a self-report measure that provides a less time-intensive and less expensive method for identifying psychopathic individuals. Using…

  9. Construct Validity of the Anxiety Sensitivity Index-3 in Clinical Samples

    ERIC Educational Resources Information Center

    Kemper, Christoph J.; Lutz, Johannes; Bahr, Tobias; Ruddel, Heinz; Hock, Michael

    2012-01-01

    Using two clinical samples of patients, the presented studies examined the construct validity of the recently revised Anxiety Sensitivity Index-3 (ASI-3). Confirmatory factor analyses established a clear three-factor structure that corresponds to the postulated subdivision of the construct into correlated somatic, social, and cognitive components.…

  10. An Evaluation of the Technical Adequacy of a Revised Measure of Quality Indicators of Transition

    ERIC Educational Resources Information Center

    Morningstar, Mary E.; Lee, Hyunjoo; Lattin, Dana L.; Murray, Angela K.

    2016-01-01

    This study confirmed the reliability and validity of the Quality Indicators of Exemplary Transition Programs Needs Assessment-2 (QI-2). Quality transition program indicators were identified through a systematic synthesis of transition research, policies, and program evaluation measures. To verify reliability and validity of the QI-2, we…

  11. Studying Cross-Cultural Differences in Temperament in the First Year of Life: United States and Italy

    ERIC Educational Resources Information Center

    Montirosso, Rosario; Cozzi, Patrizia; Putnam, Samuel P.; Gartstein, Maria A.; Borgatti, Renato

    2011-01-01

    An Italian translation of the Infant Behavior Questionnaire-Revised (IBQ-R) was developed and evaluated with 110 infants, demonstrating satisfactory internal consistency, discriminant validity, and construct validity in the form of gender and age differences, as well as factorial integrity. Cross-cultural differences were subsequently evaluated…

  12. Factorial Validity and Psychometric Examination of the Exercise Dependence Scale-Revised

    ERIC Educational Resources Information Center

    Downs, Danielle Symons; Hausenblas, Heather A.; Nigg, Claudio R.

    2004-01-01

    The research purposes were to examine the factorial and convergent validity, internal consistency, and test-retest reliability of the Exercise Dependence Scale (EDS). Two separate studies, containing a total of 1,263 college students, were undertaken to accomplish these purposes. Participants completed the EDS and measures of exercise behavior and…

  13. Body-Worn Sensors in Parkinson's Disease: Evaluating Their Acceptability to Patients.

    PubMed

    Fisher, James M; Hammerla, Nils Y; Rochester, Lynn; Andras, Peter; Walker, Richard W

    2016-01-01

    Remote monitoring of symptoms in Parkinson's disease (PD) using body-worn sensors would assist treatment decisions and evaluation of new treatments. To date, a rigorous, systematic evaluation of the acceptability of body-worn sensors in PD has not been undertaken. Thirty-four participants wore bilateral wrist-worn sensors for 4 h in a research facility and then for 1 week at home. Participants' experiences of wearing the sensors were evaluated using a Likert-style questionnaire after each phase. Qualitative data were collected through free-text responses. Differences in responses between phases were assessed by using the Wilcoxon rank-sum test. Content analysis of qualitative data was undertaken. "Non-wear time" was estimated via analysis of accelerometer data for periods when sensors were stationary. After prolonged wearing there was a negative shift in participants' views on the comfort of the sensor; problems with the sensor's strap were highlighted. However, accelerometer data demonstrated high patient concordance with wearing of the sensors. There was no evidence that participants were less likely to wear the sensors in public. Most participants preferred wearing the sensors to completing symptom diaries. The finding that participants were not less likely to wear the sensors in public provides reassurance regarding the ecological validity of the data captured. The validity of our findings was strengthened by "triangulation" of data sources, enabling patients to express their agenda and repeated assessment after prolonged wearing. Long-term monitoring with wrist-worn sensors is acceptable to this cohort of PD patients. Evaluation of the wearer's experience is critical to the development of remote monitoring technology.

  14. Brief report: Assessing dispositional optimism in adolescence--factor structure and concurrent validity of the Life Orientation Test--Revised.

    PubMed

    Monzani, Dario; Steca, Patrizia; Greco, Andrea

    2014-02-01

    Dispositional optimism is an individual difference promoting psychosocial adjustment and well-being during adolescence. Dispositional optimism was originally defined as a one-dimensional construct; however, empirical evidence suggests two correlated factors in the Life Orientation Test - Revised (LOT-R). The main aim of the study was to evaluate the dimensionality of the LOT-R. This study is the first attempt to identify the best factor structure, comparing congeneric, two correlated-factor, and two orthogonal-factor models in a sample of adolescents. Concurrent validity was also assessed. The results demonstrated the superior fit of the two orthogonal-factor model thus reconciling the one-dimensional definition of dispositional optimism with the bi-dimensionality of the LOT-R. Moreover, the results of correlational analyses proved the concurrent validity of this self-report measure: optimism is moderately related to indices of psychosocial adjustment and well-being. Thus, the LOT-R is a useful, valid, and reliable self-report measure to properly assess optimism in adolescence. Copyright © 2013 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  15. Sensor planning for moving targets

    NASA Astrophysics Data System (ADS)

    Musman, Scott A.; Lehner, Paul; Elsaesser, Chris

    1994-10-01

    Planning a search for moving ground targets is difficult for humans and computationally intractable. This paper describes a technique to solve such problems. The main idea is to combine probability of detection assessments with computational search heuristics to generate sensor plans which approximately maximize either the probability of detection or a user- specified knowledge function (e.g., determining the target's probable destination; locating the enemy tanks). In contrast to super computer-based moving target search planning, our technique has been implemented using workstation technology. The data structures generated by sensor planning can be used to evaluate sensor reports during plan execution. Our system revises its objective function with each sensor report, allowing the user to assess both the current situation as well as the expected value of future information. This capability is particularly useful in situations involving a high rate of sensor reporting, helping the user focus his attention on sensors reports most pertinent to current needs. Our planning approach is implemented in a three layer architecture. The layers are: mobility analysis, followed by sensor coverage analysis, and concluding with sensor plan analysis. It is possible using these layers to describe the physical, spatial, and temporal characteristics of a scenario in the first two layers, and customize the final analysis to specific intelligence objectives. The architecture also allows a user to customize operational parameters in each of the three major components of the system. As examples of these performance options, we briefly describe the mobility analysis and discuss issues affecting sensor plan analysis.

  16. Occurence of adverse events due to continuous glucose monitoring.

    PubMed

    Jadviscokova, Tereza; Fajkusova, Zuzana; Pallayova, Maria; Luza, Jiri; Kuzmina, Galina

    2007-12-01

    Continuous glucose monitoring (CGM) using transcutaneous sensors is becoming a sophisticated method to control and regulate glucose metabolism. The transcutaneous sensor of the CGM system (CGMS Medtronic Minimed, Northridge, CA, USA) is chosen to measure glucose concentration in interstitial fluid up to three days after insertion even though its function remains stable for a longer period. The question arises, which factors really limit the period of sensor insertion without unnecessary risk. The aim of this study was to assess any adverse events occurring in the course of 9 days after the sensor insertion. In a group of 22 healthy volunteers aged 21.8+/-1.30 y (mean +/- SE) a total of 26 sensors was inserted subcutaneously in gluteal or lumbar region for 9 days. Before insertion the site was sprayed with an antiseptic (Cutasept F, Bode Chemie, Hamburg, Germany). Local adverse reactions and disturbances in general condition were examined. In the course of 184 sensor-days, there were only minor local adverse events: hypersensitivity, itching, pain, redness, burning, subcutaneous hemorrhage. Additionally, sleep disturbances, attention deficits, problems related to the CGMS monitor, to adhesive tape and/or sensor were found. None of these resulted in sensor withdrawal. In 12 volunteers (55 %) no complications were observed. The sensor function measured according to electrical signals (ISIG) failed (always on day 1-2) in 4 cases (16 %). The present FDA approved 3-day insertion period for Medtronic transcutaneous sensor does not seem to limit its use and appears to be worth a careful revision.

  17. Validation of the Five-Phase Method for Simulating Complex Fenestration Systems with Radiance against Field Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geisler-Moroder, David; Lee, Eleanor S.; Ward, Gregory J.

    2016-08-29

    The Five-Phase Method (5-pm) for simulating complex fenestration systems with Radiance is validated against field measurements. The capability of the method to predict workplane illuminances, vertical sensor illuminances, and glare indices derived from captured and rendered high dynamic range (HDR) images is investigated. To be able to accurately represent the direct sun part of the daylight not only in sensor point simulations, but also in renderings of interior scenes, the 5-pm calculation procedure was extended. The validation shows that the 5-pm is superior to the Three-Phase Method for predicting horizontal and vertical illuminance sensor values as well as glare indicesmore » derived from rendered images. Even with input data from global and diffuse horizontal irradiance measurements only, daylight glare probability (DGP) values can be predicted within 10% error of measured values for most situations.« less

  18. NASA Sea Ice and Snow Validation Program for the DMSP SSM/I: NASA DC-8 flight report

    NASA Technical Reports Server (NTRS)

    Cavalieri, D. J.

    1988-01-01

    In June 1987 a new microwave sensor called the Special Sensor Microwave Imager (SSM/I) was launched as part of the Defense Meteorological Satellite Program (DMSP). In recognition of the importance of this sensor to the polar research community, NASA developed a program to acquire the data, to convert the data into sea ice parameters, and finally to validate and archive both the SSM/I radiances and the derived sea ice parameters. Central to NASA's sea ice validation program was a series of SSM/I aircraft underflights with the NASA DC-8 airborne Laboratory. The mission (the Arctic '88 Sea Ice Mission) was completed in March 1988. This report summarizes the mission and includes a summary of aircraft instrumentation, coordination with participating Navy aircraft, flight objectives, flight plans, data collected, SSM/I orbits for each day during the mission, and lists several piggyback experiments supported during this mission.

  19. Potential of IMU Sensors in Performance Analysis of Professional Alpine Skiers

    PubMed Central

    Yu, Gwangjae; Jang, Young Jae; Kim, Jinhyeok; Kim, Jin Hae; Kim, Hye Young; Kim, Kitae; Panday, Siddhartha Bikram

    2016-01-01

    In this paper, we present an analysis to identify a sensor location for an inertial measurement unit (IMU) on the body of a skier and propose the best location to capture turn motions for training. We also validate the manner in which the data from the IMU sensor on the proposed location can characterize ski turns and performance with a series of statistical analyses, including a comparison with data collected from foot pressure sensors. The goal of the study is to logically identify the ideal location on the skier’s body to attach the IMU sensor and the best use of the data collected for the skier. The statistical analyses and the hierarchical clustering method indicate that the pelvis is the best location for attachment of an IMU, and numerical validation shows that the data collected from this location can effectively estimate the performance and characteristics of the skier. Moreover, placement of the sensor at this location does not distract the skier’s motion, and the sensor can be easily attached and detached. The findings of this study can be used for the development of a wearable device for the routine training of professional skiers. PMID:27043579

  20. Integral Sensor Fault Detection and Isolation for Railway Traction Drive.

    PubMed

    Garramiola, Fernando; Del Olmo, Jon; Poza, Javier; Madina, Patxi; Almandoz, Gaizka

    2018-05-13

    Due to the increasing importance of reliability and availability of electric traction drives in Railway applications, early detection of faults has become an important key for Railway traction drive manufacturers. Sensor faults are important sources of failures. Among the different fault diagnosis approaches, in this article an integral diagnosis strategy for sensors in traction drives is presented. Such strategy is composed of an observer-based approach for direct current (DC)-link voltage and catenary current sensors, a frequency analysis approach for motor current phase sensors and a hardware redundancy solution for speed sensors. None of them requires any hardware change requirement in the actual traction drive. All the fault detection and isolation approaches have been validated in a Hardware-in-the-loop platform comprising a Real Time Simulator and a commercial Traction Control Unit for a tram. In comparison to safety-critical systems in Aerospace applications, Railway applications do not need instantaneous detection, and the diagnosis is validated in a short time period for reliable decision. Combining the different approaches and existing hardware redundancy, an integral fault diagnosis solution is provided, to detect and isolate faults in all the sensors installed in the traction drive.

  1. Integral Sensor Fault Detection and Isolation for Railway Traction Drive

    PubMed Central

    del Olmo, Jon; Poza, Javier; Madina, Patxi; Almandoz, Gaizka

    2018-01-01

    Due to the increasing importance of reliability and availability of electric traction drives in Railway applications, early detection of faults has become an important key for Railway traction drive manufacturers. Sensor faults are important sources of failures. Among the different fault diagnosis approaches, in this article an integral diagnosis strategy for sensors in traction drives is presented. Such strategy is composed of an observer-based approach for direct current (DC)-link voltage and catenary current sensors, a frequency analysis approach for motor current phase sensors and a hardware redundancy solution for speed sensors. None of them requires any hardware change requirement in the actual traction drive. All the fault detection and isolation approaches have been validated in a Hardware-in-the-loop platform comprising a Real Time Simulator and a commercial Traction Control Unit for a tram. In comparison to safety-critical systems in Aerospace applications, Railway applications do not need instantaneous detection, and the diagnosis is validated in a short time period for reliable decision. Combining the different approaches and existing hardware redundancy, an integral fault diagnosis solution is provided, to detect and isolate faults in all the sensors installed in the traction drive. PMID:29757251

  2. Cross-Calibration of Earth Observing System Terra Satellite Sensors MODIS and ASTER

    NASA Technical Reports Server (NTRS)

    McCorkel, J.

    2014-01-01

    The Advanced Spaceborne Thermal Emissive and Reflection Radiometer (ASTER) and Moderate Resolution Imaging Spectrometer (MODIS) are two of the five sensors onboard the Earth Observing System's Terra satellite. These sensors share many similar spectral channels while having much different spatial and operational parameters. ASTER is a tasked sensor and sometimes referred to a zoom camera of the MODIS that collects a full-earth image every one to two days. It is important that these sensors have a consistent characterization and calibration for continued development and use of their data products. This work uses a variety of test sites to retrieve and validate intercalibration results. The refined calibration of Collection 6 of the Terra MODIS data set is leveraged to provide the up-to-date reference for trending and validation of ASTER. Special attention is given to spatially matching radiance measurements using prelaunch spatial response characterization of MODIS. Despite differences in spectral band properties and spatial scales, ASTER-MODIS is an ideal case for intercomparison since the sensors have nearly identical views and acquisitions times and therefore can be used as a baseline of intercalibration performance of other satellite sensor pairs.

  3. Brazilian Portuguese version of the Revised Fibromyalgia Impact Questionnaire (FIQR-Br): cross-cultural validation, reliability, and construct and structural validation.

    PubMed

    Lupi, Jaqueline Basilio; Carvalho de Abreu, Daniela Cristina; Ferreira, Mariana Candido; Oliveira, Renê Donizeti Ribeiro de; Chaves, Thais Cristina

    2017-08-01

    This study aimed to culturally adapt and validate the Revised Fibromyalgia Impact Questionnaire (FIQR) to Brazilian Portuguese, by the use of analysis of internal consistency, reliability, and construct and structural validity. A total of 100 female patients with fibromyalgia participated in the validation process of the Brazilian Portuguese version of the FIQR (FIQR-Br).The intraclass correlation coefficient (ICC) was used for statistical analysis of reliability (test-retest), Cronbach's alpha for internal consistency, Pearson's rank correlation for construct validity, and confirmatory factor analysis (CFA) for structural validity. It was verified excellent levels of reliability, with ICC greater than 0.75 for all questions and domains of the FIQR-Br. For internal consistency, alpha values greater than 0.70 for the items and domains of the questionnaire were observed. Moderate (0.40 < r < 0.70) and strong (r > 0.70) correlations were observed for the scores of domains and total score between the FIQR-Br and FIQ-Br. The structure of the three domains of the FIQR-Br was confirmed by CFA. The results of this study suggest that that the FIQR-Br is a reliable and valid instrument for assessing fibromyalgia-related impact, and supports its use in clinical settings and research. The structure of the three domains of the FIQR-Br was also confirmed. Implications for Rehabilitation Fibromyalgia is a chronic musculoskeletal disorder characterized by widespread and diffuse pain, fatigue, sleep disturbances, and depression. The disease significantly impairs patients' quality of life and can be highly disabling. To be used in multicenter research efforts, the Revised Fibromyalgia Impact Questionnaire (FIQR) must be cross-culturally validated and psychometrically tested. This paper will make available a new version of the FIQR-Br since another version already exists, but there are concerns about its measurement properties. The availability of an instrument adapted to and validated for Brazilian Portuguese may make it possible to reliably verify the effects of rehabilitation programs on disability from fibromyalgia. The FIQR-Br showed results comparable with other versions of the FIQR in other languages, thereby enabling comparison of effects of rehabilitation interventions on disability from fibromyalgia conducted in Brazil with results of studies carried out in other parts of the world.

  4. Advanced Magnetic Head Development Revision 1 Final Report CRADA No. TC-0840-94

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cerjan, C.; Shi, S.

    The specific go,il of this research was the development of a prototype read magnetic sensor head using the Current:Perpendicular-to-Plane (CPP) geometry with known GMR (Giant Magneto-Resistive) multilayered structures to achieve read densities greater than 10 Gbit/in2, field sensitivities greater than 1%/Oe, switching fields less than 20 Oe, and total MR response greater than 10%. The specific materials needed for this idcnl behavior had to be determined, as did the eventual design of the sensor (placement of contact leads, shields, and biasing magnets). Thus the thrust of the rescnrch required a search for the proper multilayer material combination und the developmentmore » of a simulation capability to guide sensor design. Issues i:elated to device integration, such as media noise and lead contact resistance, were also recognized as important technological hurdles but these items were deferred until the operating conditions of the-prototype GMR sensor were more precisely determined.« less

  5. Sensor Applications and Data Validation

    NASA Technical Reports Server (NTRS)

    Wiley, John

    2008-01-01

    The mechanical configuration of automobiles have changed marginally while improvements in sensors and control have dramatically improved engine efficiency, reliability and useful life. The aviation industry has also taken advantage of sensors and control systems to reduce operational costs. Sensors and high fidelity control systems fly planes at levels of performance beyond human capability. Sophisticated environmental controls allow a greater level of comfort and efficiency in our homes. Sensors have given the medical field a better understanding of the human body and the environment in which we live.

  6. Transmission-grating-based wavefront tilt sensor.

    PubMed

    Iwata, Koichi; Fukuda, Hiroki; Moriwaki, Kousuke

    2009-07-10

    We propose a new type of tilt sensor. It consists of a grating and an image sensor. It detects the tilt of the collimated wavefront reflected from a plane mirror. Its principle is described and analyzed based on wave optics. Experimental results show its validity. Simulations of the ordinary autocollimator and the proposed tilt sensor show that the effect of noise on the measured angle is smaller for the latter. These results show a possibility of making a smaller and simpler tilt sensor.

  7. Flight evaluation of advanced third-generation midwave infrared sensor

    NASA Astrophysics Data System (ADS)

    Shen, Chyau N.; Donn, Matthew

    1998-08-01

    In FY-97 the Counter Drug Optical Upgrade (CDOU) demonstration program was initiated by the Program Executive Office for Counter Drug to increase the detection and classification ranges of P-3 counter drug aircraft by using advanced staring infrared sensors. The demonstration hardware is a `pin-for-pin' replacement of the AAS-36 Infrared Detection Set (IRDS) located under the nose radome of a P-3 aircraft. The hardware consists of a 3rd generation mid-wave infrared (MWIR) sensor integrated into a three axis-stabilized turret. The sensor, when installed on the P- 3, has a hemispheric field of regard and analysis has shown it will be capable of detecting and classifying Suspected Drug Trafficking Aircraft and Vessels at ranges several factors over the current IRDS. This paper will discuss the CDOU system and it's lab, ground, and flight evaluation results. Test targets included target templates, range targets, dedicated target boats, and targets of opportunity at the Naval Air Warfare Center Aircraft Division and at operational test sites. The objectives of these tests were to: (1) Validate the integration concept of the CDOU package into the P-3 aircraft. (2) Validate the end-to-end functionality of the system, including sensor/turret controls and recording of imagery during flight. (3) Evaluate the system sensitivity and resolution on a set of verified resolution targets templates. (4) Validate the ability of the 3rd generation MWIR sensor to detect and classify targets at a significantly increased range.

  8. Assessing Saudi medical students learning approach using the revised two-factor study process questionnaire.

    PubMed

    Shaik, Shaffi Ahamed; Almarzuqi, Ahmed; Almogheer, Rakan; Alharbi, Omar; Jalal, Abdulaziz; Alorainy, Majed

    2017-08-17

    To assess learning approaches of 1st, 2nd, and 3rd-year medical students by using revised two-factor study process questionnaire, and to assess reliability and validity of the questionnaire. This cross-sectional study was conducted at the College of Medicine, Riyadh, Saudi Arabia in 2014. The revised two-factor study process questionnaire (R-SPQ-2F) was completed by 610 medical students of both genders, from foundation (first year), central nervous system (second year), medicine and surgery (third year) courses. The study process was evaluated by computing mean scores of two research study approaches (deep & surface) using student's t-test and one-way analysis of variance. The internal consistency and construct validity of the questionnaire were assessed using Cronbach's α and factor analysis. The mean score of deep approach was significantly higher than the surface approach among participants(t (770) =7.83, p= 0.000) for the four courses. The mean scores of deep approach were significantly higher among participants with higher grade point average (F (2,768) =13.31, p=0.001) along with more number of study hours by participants (F (2,768) =20.08, p=0.001). The Cronbach's α-values of items at 0.70 indicate the good internal consistency of questionnaire used. Factor analysis confirms two factors (deep and surface approaches) of R-SPQ-2F. The deep approach to learning was the primary approach among 1st, 2nd and 3rd-year King Saud University medical students. This study confirms reliability and validity of the revised two-factor study process questionnaire. Medical educators could use the results of such studies to make required changes in the curriculum.

  9. Metrology for hydrogen energy applications: a project to address normative requirements

    NASA Astrophysics Data System (ADS)

    Haloua, Frédérique; Bacquart, Thomas; Arrhenius, Karine; Delobelle, Benoît; Ent, Hugo

    2018-03-01

    Hydrogen represents a clean and storable energy solution that could meet worldwide energy demands and reduce greenhouse gases emission. The joint research project (JRP) ‘Metrology for sustainable hydrogen energy applications’ addresses standardisation needs through pre- and co-normative metrology research in the fast emerging sector of hydrogen fuel that meet the requirements of the European Directive 2014/94/EU by supplementing the revision of two ISO standards that are currently too generic to enable a sustainable implementation of hydrogen. The hydrogen purity dispensed at refueling points should comply with the technical specifications of ISO 14687-2 for fuel cell electric vehicles. The rapid progress of fuel cell technology now requires revising this standard towards less constraining limits for the 13 gaseous impurities. In parallel, optimized validated analytical methods are proposed to reduce the number of analyses. The study aims also at developing and validating traceable methods to assess accurately the hydrogen mass absorbed and stored in metal hydride tanks; this is a research axis for the revision of the ISO 16111 standard to develop this safe storage technique for hydrogen. The probability of hydrogen impurity presence affecting fuel cells and analytical techniques for traceable measurements of hydrogen impurities will be assessed and new data of maximum concentrations of impurities based on degradation studies will be proposed. Novel validated methods for measuring the hydrogen mass absorbed in hydrides tanks AB, AB2 and AB5 types referenced to ISO 16111 will be determined, as the methods currently available do not provide accurate results. The outputs here will have a direct impact on the standardisation works for ISO 16111 and ISO 14687-2 revisions in the relevant working groups of ISO/TC 197 ‘Hydrogen technologies’.

  10. Grain shape influence on semiconducting metal oxide based gas sensor performance: modeling versus experiment.

    PubMed

    Rebholz, Julia; Bonanati, Peter; Weimar, Udo; Barsan, Nicolae

    2014-06-01

    A model for sensing with semiconducting metal oxide (SMOX)-based gas sensors was developed which takes the effect of the shape of the grains in the sensing layers into account. Its validity is limited to materials in which the grains of the SMOX sensing layer are large enough to have an undepleted bulk region (large grains). This means that in all experimental conditions, the SMOX properties ensure that the influence of surface phenomena is not extended to the whole grain. The model takes the surface chemistry and its impact on the electrical properties of the sensing material into consideration. In this way, it relates the sensor signal--defined as the relative change of the sensor's conductance--directly to the concentration of the target gas and also exhibits meaningful chemical parameters, such as the type of reactive oxygen species, the reaction constants, and the concentration of adsorption sites. The validity of the model is confirmed experimentally by applying it to data gathered by measuring homemade sensors in relevant conditions.

  11. CATSI EDM: recent advances in the development and validation of a ruggedized passive standoff CWA sensor

    NASA Astrophysics Data System (ADS)

    Lavoie, Hugo; Thériault, Jean-Marc; Bouffard, François; Puckrin, Eldon; Turcotte, Caroline S.; Lacasse, Paul

    2008-04-01

    Defence Research and Development Canada (DRDC) - Valcartier is currently developing a ruggedized passive standoff sensor for the detection of chemical warfare agents (CWAs) based on differential Fourier-transform infrared (FTIR) radiometry. This system is referred to as the Compact ATmospheric Sounding Interferometer (CATSI) Engineering Development Model (EDM). The CATSI EDM sensor is based on the use of a double-beam FTIR spectrometer that is optimized for optical subtraction. A description of the customized sensor is given along with a discussion on the detection and identification approaches that have been developed. Preliminary results of validation from a number of laboratory measurements and open-air trials are analyzed to establish the capability of detection and identification of various toxic and non-toxic chemical vapor plumes. These results clearly demonstrate the capability of the passive differential radiometric approach for the standoff detection and identification of chemical vapors at distances up to a few kilometers from the sensor.

  12. Validation of Underwater Sensor Package Using Feature Based SLAM

    PubMed Central

    Cain, Christopher; Leonessa, Alexander

    2016-01-01

    Robotic vehicles working in new, unexplored environments must be able to locate themselves in the environment while constructing a picture of the objects in the environment that could act as obstacles that would prevent the vehicles from completing their desired tasks. In enclosed environments, underwater range sensors based off of acoustics suffer performance issues due to reflections. Additionally, their relatively high cost make them less than ideal for usage on low cost vehicles designed to be used underwater. In this paper we propose a sensor package composed of a downward facing camera, which is used to perform feature tracking based visual odometry, and a custom vision-based two dimensional rangefinder that can be used on low cost underwater unmanned vehicles. In order to examine the performance of this sensor package in a SLAM framework, experimental tests are performed using an unmanned ground vehicle and two feature based SLAM algorithms, the extended Kalman filter based approach and the Rao-Blackwellized, particle filter based approach, to validate the sensor package. PMID:26999142

  13. Assessment and certification of neonatal incubator sensors through an inferential neural network.

    PubMed

    de Araújo, José Medeiros; de Menezes, José Maria Pires; Moura de Albuquerque, Alberto Alexandre; da Mota Almeida, Otacílio; Ugulino de Araújo, Fábio Meneghetti

    2013-11-15

    Measurement and diagnostic systems based on electronic sensors have been increasingly essential in the standardization of hospital equipment. The technical standard IEC (International Electrotechnical Commission) 60601-2-19 establishes requirements for neonatal incubators and specifies the calibration procedure and validation tests for such devices using sensors systems. This paper proposes a new procedure based on an inferential neural network to evaluate and calibrate a neonatal incubator. The proposal presents significant advantages over the standard calibration process, i.e., the number of sensors is drastically reduced, and it runs with the incubator under operation. Since the sensors used in the new calibration process are already installed in the commercial incubator, no additional hardware is necessary; and the calibration necessity can be diagnosed in real time without the presence of technical professionals in the neonatal intensive care unit (NICU). Experimental tests involving the aforementioned calibration system are carried out in a commercial incubator in order to validate the proposal.

  14. Assessment and Certification of Neonatal Incubator Sensors through an Inferential Neural Network

    PubMed Central

    de Araújo Júnior, José Medeiros; de Menezes Júnior, José Maria Pires; de Albuquerque, Alberto Alexandre Moura; Almeida, Otacílio da Mota; de Araújo, Fábio Meneghetti Ugulino

    2013-01-01

    Measurement and diagnostic systems based on electronic sensors have been increasingly essential in the standardization of hospital equipment. The technical standard IEC (International Electrotechnical Commission) 60601-2-19 establishes requirements for neonatal incubators and specifies the calibration procedure and validation tests for such devices using sensors systems. This paper proposes a new procedure based on an inferential neural network to evaluate and calibrate a neonatal incubator. The proposal presents significant advantages over the standard calibration process, i.e., the number of sensors is drastically reduced, and it runs with the incubator under operation. Since the sensors used in the new calibration process are already installed in the commercial incubator, no additional hardware is necessary; and the calibration necessity can be diagnosed in real time without the presence of technical professionals in the neonatal intensive care unit (NICU). Experimental tests involving the aforementioned calibration system are carried out in a commercial incubator in order to validate the proposal. PMID:24248278

  15. Identifying compensatory movement patterns in the upper extremity using a wearable sensor system.

    PubMed

    Ranganathan, Rajiv; Wang, Rui; Dong, Bo; Biswas, Subir

    2017-11-30

    Movement impairments such as those due to stroke often result in the nervous system adopting atypical movements to compensate for movement deficits. Monitoring these compensatory patterns is critical for improving functional outcomes during rehabilitation. The purpose of this study was to test the feasibility and validity of a wearable sensor system for detecting compensatory trunk kinematics during activities of daily living. Participants with no history of neurological impairments performed reaching and manipulation tasks with their upper extremity, and their movements were recorded by a wearable sensor system and validated using a motion capture system. Compensatory movements of the trunk were induced using a brace that limited range of motion at the elbow. Our results showed that the elbow brace elicited compensatory movements of the trunk during reaching tasks but not manipulation tasks, and that a wearable sensor system with two sensors could reliably classify compensatory movements (~90% accuracy). These results show the potential of the wearable system to assess and monitor compensatory movements outside of a lab setting.

  16. Using the Autism Diagnostic Interview-Revised and the Autism Diagnostic Observation Schedule with Young Children with Developmental Delay: Evaluating Diagnostic Validity

    ERIC Educational Resources Information Center

    Gray, Kylie M.; Tonge, Bruce J.; Sweeney, Deborah J.

    2008-01-01

    Few studies have focused on the validity of the ADI-R and ADOS in the assessment of preschool children with developmental delay. This study aimed to evaluate the diagnostic validity of the ADI-R and the ADOS in young children. Two-hundred and nine children aged 20-55 months participated in the study, 120 of whom received a diagnosis of autism.…

  17. The Perceived School Climate in Invitational Schools in Hong Kong: Using the Chinese Version of the Inviting School Survey-Revised (ISS-R)

    ERIC Educational Resources Information Center

    Ng, Carmen K. M.; Yuen, Mantak

    2011-01-01

    This article describes the use of the Chinese translation of the revised Inviting School Survey (ISS-R; Smith, 2005; Smith & Bernard, 2004) to measure the invitational climate of seven invitational secondary schools in Hong Kong. The five subscales of Chinese version of ISS-R were found to be valid and reliable in a sample of 706 Grade 11…

  18. Autism Diagnostic Interview-Revised (ADI-R) Algorithms for Toddlers and Young Preschoolers: Application in a Non-US Sample of 1,104 Children

    ERIC Educational Resources Information Center

    de Bildt, Annelies; Sytema, Sjoerd; Zander, Eric; Bölte, Sven; Sturm, Harald; Yirmiya, Nurit; Yaari, Maya; Charman, Tony; Salomone, Erica; LeCouteur, Ann; Green, Jonathan; Bedia, Ricardo Canal; Primo, Patricia García; van Daalen, Emma; de Jonge, Maretha V.; Guðmundsdóttir, Emilía; Jóhannsdóttir, Sigurrós; Raleva, Marija; Boskovska, Meri; Rogé, Bernadette; Baduel, Sophie; Moilanen, Irma; Yliherva, Anneli; Buitelaar, Jan; Oosterling, Iris J.

    2015-01-01

    The current study aimed to investigate the Autism Diagnostic Interview-Revised (ADI-R) algorithms for toddlers and young preschoolers (Kim and Lord, "J Autism Dev Disord" 42(1):82-93, 2012) in a non-US sample from ten sites in nine countries (n = 1,104). The construct validity indicated a good fit of the algorithms. The diagnostic…

  19. A Translation and Validation Study of the Life Orientation Test Revised in the Greek Speaking Population of Nurses among Three Hospitals in Athens and Ioannina

    ERIC Educational Resources Information Center

    Lyrakos, George N.; Damigos, Dimitrios; Mavreas, Venetsanos; Georgia, Kostopanagiotou; Dimoliatis, Ioannis D. K.

    2010-01-01

    The life orientation test-revised (LOT-R) (Scheier et al. in "Journal of Personality and Social Psychology" 67:1063-1078, 1994) is a brief measure for assessing dispositional optimism. The aim of this study was to develop a Greek language version of the LOT-R and to assess the instrument's psychometric properties. The LOT-R was…

  20. Predictive Validity of ICD-11 PTSD as Measured by the Impact of Event Scale-Revised: A 15-Year Prospective Study of Political Prisoners.

    PubMed

    Hyland, Philip; Brewin, Chris R; Maercker, Andreas

    2017-04-01

    The 11 th edition of the International Classification of Diseases (ICD-11; World Health Organization, 2017) proposes a model of posttraumatic stress disorder (PTSD) that includes 6 symptoms. This study assessed the ability of a classification-independent measure of posttraumatic stress symptoms, the Impact of Event Scale-Revised (Weiss & Marmar, 1996), to capture the ICD-11 model of PTSD. The current study also provided the first assessment of the predictive validity of ICD-11 PTSD. Former East German political prisoners were assessed in 1994 (N = 144) and in 2008-2009 (N = 88) on numerous psychological variables using self-report measures. Of the participants, 48.2% and 36.8% met probable diagnosis for ICD-11 PTSD at the first and second assessments, respectively. Confirmatory factor analysis supported the factorial validity of the 3-factor ICD-11 model of PTSD, as represented by items selected from the Impact of Event Scale-Revised. Hierarchical multiple regression analysis demonstrated that, controlling for sex, the symptom clusters of ICD-11 PTSD (reexperiencing, avoidance, and sense of threat) significantly contributed to the explanation of depression (R 2 = .17), quality of life (R 2 = .21), internalized anger (R 2 = .10), externalized anger (R 2 = .12), hatred of perpetrators (R 2 = .15), dysfunctional disclosure (R 2 = .27), and social acknowledgment as a victim (R 2 = .12) across the 15-year study period. Current findings add support for the factorial and predictive validity of ICD-11 PTSD within a unique cohort of political prisoners. Copyright © 2017 International Society for Traumatic Stress Studies.

  1. The Development and Validation of a Revised Version of the Math Anxiety Scale for Young Children.

    PubMed

    Ganley, Colleen M; McGraw, Amanda L

    2016-01-01

    Although there is an extensive amount of research that examines the relation between math anxiety and math performance in adolescents and adults, little work has focused on this relation in young children. Recently more attention has been paid to the early development of math anxiety, and new measures have been created for use with this age group. In the present study, we report on the development and validation of a revised version of the Math Anxiety Scale for Young Children (MASYC; Harari et al., 2013). We conducted cognitive interviews with the 12 MASYC items with nine children and then administered the MASYC and five newly-developed items to 296 first-, second- and third-grade children. Results from cognitive interviews show that three of the items from the original scale were being systematically misinterpreted by young children. We present a revised measure (the MASYC-R) consisting of 13 items (eight original, five newly-developed) that shows strong evidence for reliability and validity. Results also showed that a small, but meaningful, proportion of children at this age show signs of high math anxiety. Validity of the MASYC-R was supported through correlations with a number of other factors, including general anxiety, math performance, and math attitudes. In addition, results suggest that a substantial proportion of the variance in math anxiety can be explained from these other variables together. The findings suggest that the MASYC-R is appropriate for use with young children and can help researchers to answer important questions about the nature and development of math anxiety at this age.

  2. The Development and Validation of a Revised Version of the Math Anxiety Scale for Young Children

    PubMed Central

    Ganley, Colleen M.; McGraw, Amanda L.

    2016-01-01

    Although there is an extensive amount of research that examines the relation between math anxiety and math performance in adolescents and adults, little work has focused on this relation in young children. Recently more attention has been paid to the early development of math anxiety, and new measures have been created for use with this age group. In the present study, we report on the development and validation of a revised version of the Math Anxiety Scale for Young Children (MASYC; Harari et al., 2013). We conducted cognitive interviews with the 12 MASYC items with nine children and then administered the MASYC and five newly-developed items to 296 first-, second- and third-grade children. Results from cognitive interviews show that three of the items from the original scale were being systematically misinterpreted by young children. We present a revised measure (the MASYC-R) consisting of 13 items (eight original, five newly-developed) that shows strong evidence for reliability and validity. Results also showed that a small, but meaningful, proportion of children at this age show signs of high math anxiety. Validity of the MASYC-R was supported through correlations with a number of other factors, including general anxiety, math performance, and math attitudes. In addition, results suggest that a substantial proportion of the variance in math anxiety can be explained from these other variables together. The findings suggest that the MASYC-R is appropriate for use with young children and can help researchers to answer important questions about the nature and development of math anxiety at this age. PMID:27605917

  3. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  4. Reliability and Validity of the Revised Summary of Diabetes Self-Care Activities (SDSCA) for Malaysian Children and Adolescents.

    PubMed

    Jalaludin, My; Fuziah, Mz; Hong, Jyh; Mohamad Adam, B; Jamaiyah, H

    2012-01-01

    Self-care plays an important role in diabetes management. One of the instruments used to evaluate self-care in patients with diabetes is the Summary of Diabetes Self-Care Activities (SDSCA) questionnaire. A validated instrument in the Malay language is used to assess self-care practice among children and adolescents with diabetes in Malaysia. To translate and evaluate the psychometric properties of the revised version of the SDSCA questionnaire in the Malay language. Forward and backward translations were performed. An expert panel reviewed all versions for conceptual and content equivalence. The final version was administered to paediatric patients with diabetes between August 2006 and September 2007. Reliability was analysed using Cronbach's alpha and validity was assessed using exploratory factor analysis. A total of 117 patients aged 10-18 years were enrolled from nine hospitals. The reliability of overall core items was 0.735 (with item 4) while the reliabilities of the four domains were in the range of 0.539-0.838. As core item number 4 was found to be problematic and it was subtituted by item 5a (from the expanded SDSCA) to suit local dietary education and practice; and the reliabilities of the overall core item (0.782) and the four domains (0.620 - 0.838) improved. Factor loadings of all the items were greater than 0.4, loaded into the original domains, and accounted for 73% of the total variance. The Malay translation of the revised English SDSCA is reliable and valid as a guide for Malaysian children and adolescents suffering from diabetes.

  5. Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Bilo, Grzegorz; Zorzi, Cristina; Ochoa Munera, Juan E; Torlasco, Camilla; Giuli, Valentina; Parati, Gianfranco

    2015-10-01

    The present study aimed to evaluate the accuracy of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults (11 women, mean age 63.5±11.9 years) using a mercury sphygmomanometer (two observers) and the Somnotouch-NIBP device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the validation requirements were fulfilled. The Somnotouch-NIBP device fulfilled the requirements of the part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 75/99, 90/99, and 96/99, respectively, for systolic blood pressure and 90/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-seven and 31 participants had at least two of the three device-observers differences less than or equal to 5 mmHg for systolic and diastolic blood pressure, respectively. All three device-observer differences were greater than 5 mmHg in two participants for systolic and in one participant for diastolic blood pressure. The Somnotouch-NIBP noninvasive continuous blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure monitoring in adults, at least under conditions corresponding to those investigated in our study.

  6. Reliability and Validity of the Korean Version of the Lifetime Stressor Checklist-Revised in Psychiatric Outpatients with Anxiety or Depressive Disorders.

    PubMed

    Choi, Kang Rok; Kim, Daeho; Jang, Eun Young; Bae, Hwallip; Kim, Seok Hyeon

    2017-01-01

    Traumatic events and adverse stressful experiences are major etiological factors in a wide variety of physical and mental disorders. Developing psychological instruments that can be easily administered and that have good psychometric properties have become an integral part for research and practice. This study investigated the reliability and validity of the Korean version of the Lifetime Stressor Checklist-Revised (LSC-R) in a consecutive sample of psychiatric outpatients. The LSC-R is a 30-item self-reporting questionnaire examining lifetime traumatic and non-traumatic stressors. A final sample of 258 outpatients with anxiety or depressive disorders was recruited at the psychiatric department of a university-affiliated teaching hospital. Self-reported data included the Life Events Checklist (LEC), the Zung Self-Rating Depression and Anxiety Scales, and the Impact of Events Scale-Revised, in addition to the LSC-R. A convenience sample of 50 college students completed the LSC-R on two occasions separated by a three week-interval for test-retest reliability. Mean kappa for temporal stability was high (κ=0.651) and Cronbach alpha was moderate (α=0.724). Convergent validity was excellent with corresponding items on the LEC. Concurrent validity was good for symptoms of post-traumatic stress disorder, depression, and anxiety. An exploratory factor analysis revealed that 11 factors explained 64.3 % of the total variance. This study demonstrated good psychometric properties of the Korean version of the LSC-R, further supporting its use in clinical research and practice with a Korean speaking population.

  7. On demand processing of climate station sensor data

    NASA Astrophysics Data System (ADS)

    Wöllauer, Stephan; Forteva, Spaska; Nauss, Thomas

    2015-04-01

    Large sets of climate stations with several sensors produce big amounts of finegrained time series data. To gain value of this data, further processing and aggregation is needed. We present a flexible system to process the raw data on demand. Several aspects need to be considered to process the raw data in a way that scientists can use the processed data conveniently for their specific research interests. First of all, it is not feasible to pre-process the data in advance because of the great variety of ways it can be processed. Therefore, in this approach only the raw measurement data is archived in a database. When a scientist requires some time series, the system processes the required raw data according to the user-defined request. Based on the type of measurement sensor, some data validation is needed, because the climate station sensors may produce erroneous data. Currently, three validation methods are integrated in the on demand processing system and are optionally selectable. The most basic validation method checks if measurement values are within a predefined range of possible values. For example, it may be assumed that an air temperature sensor measures values within a range of -40 °C to +60 °C. Values outside of this range are considered as a measurement error by this validation method and consequently rejected. An other validation method checks for outliers in the stream of measurement values by defining a maximum change rate between subsequent measurement values. The third validation method compares measurement data to the average values of neighboring stations and rejects measurement values with a high variance. These quality checks are optional, because especially extreme climatic values may be valid but rejected by some quality check method. An other important task is the preparation of measurement data in terms of time. The observed stations measure values in intervals of minutes to hours. Often scientists need a coarser temporal resolution (days, months, years). Therefore, the interval of time aggregation is selectable for the processing. For some use cases it is desirable that the resulting time series are as continuous as possible. To meet these requirements, the processing system includes techniques to fill gaps of missing values by interpolating measurement values with data from adjacent stations using available contemporaneous measurements from the respective stations as training datasets. Alongside processing of sensor values, we created interactive visualization techniques to get a quick overview of a big amount of archived time series data.

  8. Evidence-Based School Behavior Assessment of Externalizing Behavior in Young Children

    PubMed Central

    Bagner, Daniel M.; Boggs, Stephen R.; Eyberg, Sheila M.

    2011-01-01

    This study examined the psychometric properties of the Revised Edition of the School Observation Coding System (REDSOCS). Participants were 68 children ages 3 to 6 who completed parent-child interaction therapy for Oppositional Defiant Disorder as part of a larger efficacy trial. Interobserver reliability on REDSOCS categories was moderate to high, with percent agreement ranging from 47% to 90% (M = 67%) and Cohen’s kappa coefficients ranging from .69 to .95 (M = .82). Convergent validity of the REDSOCS categories was supported by significant correlations with the Intensity Scale of the Sutter-Eyberg Student Behavior Inventory-Revised and related subscales of the Conners’ Teacher Rating Scale-Revised: Long Version (CTRS-R: L). Divergent validity was indicated by nonsignificant correlations between REDSOCS categories and scales on the CTRS-R: L expected not to relate to disruptive classroom behavior. Treatment sensitivity was demonstrated for two of the three primary REDSOCS categories by significant pre to posttreatment changes. This study provides psychometric support for the designation of REDSOCS as an evidence-based assessment procedure for young children. PMID:21687781

  9. TAMDAR Sensor Validation in 2003 AIRS II

    NASA Technical Reports Server (NTRS)

    Daniels, Taumi S.; Murray, John J.; Anderson, Mark V.; Mulally, Daniel J.; Jensen, Kristopher R.; Grainger, Cedric A.; Delene, David J.

    2005-01-01

    This study entails an assessment of TAMDAR in situ temperature, relative humidity and winds sensor data from seven flights of the UND Citation II. These data are undergoing rigorous assessment to determine their viability to significantly augment domestic Meteorological Data Communications Reporting System (MDCRS) and the international Aircraft Meteorological Data Reporting (AMDAR) system observational databases to improve the performance of regional and global numerical weather prediction models. NASA Langley Research Center participated in the Second Alliance Icing Research Study from November 17 to December 17, 2003. TAMDAR data taken during this period is compared with validation data from the UND Citation. The data indicate acceptable performance of the TAMDAR sensor when compared to measurements from the UND Citation research instruments.

  10. A multifunctional PVDF-based tactile sensor for minimally invasive surgery

    NASA Astrophysics Data System (ADS)

    Sokhanvar, S.; Packirisamy, M.; Dargahi, J.

    2007-08-01

    In this paper a multifunctional tactile sensor system using PVDF (polyvinylidene fluoride), is proposed, designed, analyzed, tested and validated. The working principle of the sensor is in such a way that it can be used in combination with almost any end-effectors. However, the sensor is particularly designed to be integrated with minimally invasive surgery (MIS) tools. In addition, the structural and transduction materials are selected to be compatible with micro-electro-mechanical systems (MEMS) technology, so that miniaturization would be possible. The corrugated shape of the sensor ensures the safe tissue grasping and compatibility with the traditional tooth-like end effectors of MIS tools. A unit of this sensor comprised of a base, a flexible beam and three PVDF sensing elements. Two PVDF sensing elements sandwiched at the end supports work in thickness mode to measure the magnitude and position of applied load. The third PVDF sensing element is attached to the beam and it works in the extensional mode to measure the softness of the contact object. The proposed sensor is modeled both analytically and numerically and a series of simulations are performed in order to estimate the characteristics of the sensor in measuring the magnitude and position of a point load, distributed load, and also the softness of the contact object. Furthermore, in order to validate the theoretical results, the prototyped sensor was tested and the results are compared. The results are very promising and proving the capability of the sensor for haptic sensing.

  11. Sensor Technology Assessment for Ordnance and Explosive Waste Detection and Location. Revision B.

    DTIC Science & Technology

    1995-03-01

    5 Figure 1.5 Examples Of Anti-Tank Mines .................... .................... 5 Figure 1.6. Sample Drawing of a Bomb...6 Figure 1.7. Examples of Scatterable Anti-Personnel Mines (top) and Scatterable Anti-Tank Mines (bottom...individuals, and therefore the OEW items must be detected and located. OEW examples are bombs, warheads, guided missiles, mortars, small arms, mines

  12. Reliability and Validity of Parent- and Child-Rated Anxiety Measures in Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Kaat, Aaron J.; Lecavalier, Luc

    2015-01-01

    Autism spectrum disorder (ASD) and anxiety frequently co-occur. Research on the phenomenology and treatment of anxiety in ASD is expanding, but is hampered by the lack of instruments validated for this population. This study evaluated the self- and parent-reported Revised Child Anxiety and Depression Scale and the Multidimensional Anxiety Scale in…

  13. Using a Parental Checklist to Identify Diagnostic Groups in Children with Communication Impairment: A Validation of the Children's Communication Checklist--2

    ERIC Educational Resources Information Center

    Norbury, Courtenay Frazier; Nash, Marysia; Baird, Gillian; Bishop, Dorothy V. M.

    2004-01-01

    Background: The Children's Communication Checklist (CCC 1998) was revised in 2003 (CCC-2) to provide a general screen for communication disorder and to identify pragmatic/social interaction deficits. Two validation studies were conducted with different populations of children with language and communication impairments. Methods & Procedures: In…

  14. 77 FR 22689 - Revisions to Authorization Validated End-User Provisions: Requirement for Notice of Export...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-17

    ...) by adding a requirement for persons shipping under Authorization Validated End- User (VEU) to send... that when items subject to item-specific conditions under Authorization VEU no longer require a license for export or reexport or become eligible for shipment under a license exception, as set forth in the...

  15. Early Childhood Special Education and Early Intervention Personnel Preparation Standards of the Division for Early Childhood: Field Validation

    ERIC Educational Resources Information Center

    Cochran, Deborah C.; Gallagher, Peggy A.; Stayton, Vicki D.; Dinnebeil, Laurie A.; Lifter, Karin; Chandler, Lynette K.; Christensen, Kimberly A.

    2012-01-01

    Results of the field validation survey of the revised initial and new advanced Council for Exceptional Children (CEC) Division for Early Childhood (DEC) early childhood special education (ECSE)/early intervention (EI) personnel standards are presented. Personnel standards are used as part of educational accountability systems and in teacher…

  16. The Content Validity of Juvenile Psychopathy: An Empirical Examination

    ERIC Educational Resources Information Center

    Lynam, Donald R.; Derefinko, Karen J.; Caspi, Avshalom; Loeber, Rolf; Stouthamer-Loeber, Magda

    2007-01-01

    This study examined the content validity of a juvenile psychopathy measure, the Childhood Psychopathy Scale (CPS; D. R. Lynam, 1997), based on a downward translation of an adult instrument, the Hare Psychopathy Checklist-Revised (PCL-R; R. D. Hare, 1991). The CPS was compared with two other indices of juvenile psychopathy: (a) an index derived…

  17. Validation of the Revised BSI-18 with Latino Migrant Day Laborers

    ERIC Educational Resources Information Center

    Negi, Nalini Junko; Iwamoto, Derek Kenji

    2014-01-01

    Objective: This study examines the factor structure of the Brief Symptom Inventory-18 (BSI-18; Derogatis, 2001) in a hard-to-reach population of mainly undocumented migrant Latino day laborers. While, the BSI-18 has been found to be a valid and reliable measure of psychological distress, cross-cultural assessments in sub-groups of Latinos are…

  18. Development and Validation of a New Measure of Teacher Perceptions of Science and Mathematics Learning Environments

    ERIC Educational Resources Information Center

    Ellett, Chad D.; Monsaas, Judy

    2011-01-01

    This article describes the development and validation of the Inventory of Teaching and Learning (ITAL) as a new measure of teacher perceptions of science and mathematics learning environments. The ITAL was initially developed and administered in 2004 and has subsequently been revised annually. The ITAL is administered using a confidential…

  19. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Guo, Wan-Gang; Li, Bing-Ling; He, Yong; Xue, Yu-Sheng; Wang, Hai-Yan; Zheng, Qiang-Sun; Xiang, Ding-Cheng

    2014-08-01

    To validate the Andon KD-5917 automatic upper arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Sequential same-left-arm measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the mercury sphygmomanometer and the test device. According to the validation protocol, 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 73, 98, and 99 measurements within 5, 10, and 15 mmHg for SBP and 86, 98, and 99 for DBP, respectively. The mean ± SD device-observer difference was 3.07 ± 3.68 mmHg for SBP and -0.89 ± 3.72 mmHg for DBP. The number of patients with two or three of the device-observer difference within 5 mmHg was 26 for SBP and 29 for DBP, and no patient had a device-observer difference within 5 mmHg. The Andon KD-5917 automatic upper arm blood pressure monitor can be recommended for clinical use and self-measurement in an adult population on the basis of the European Society of Hypertension International Protocol revision 2010.

  20. Can we really use available scales for child and adolescent psychopathology across cultures? A systematic review of cross-cultural measurement invariance data.

    PubMed

    Stevanovic, Dejan; Jafari, Peyman; Knez, Rajna; Franic, Tomislav; Atilola, Olayinka; Davidovic, Nikolina; Bagheri, Zahra; Lakic, Aneta

    2017-02-01

    In this systematic review, we assessed available evidence for cross-cultural measurement invariance of assessment scales for child and adolescent psychopathology as an indicator of cross-cultural validity. A literature search was conducted using the Medline, PsychInfo, Scopus, Web of Science, and Google Scholar databases. Cross-cultural measurement invariance data was available for 26 scales. Based on the aggregation of the evidence from the studies under review, none of the evaluated scales have strong evidence for cross-cultural validity and suitability for cross-cultural comparison. A few of the studies showed a moderate level of measurement invariance for some scales (such as the Fear Survey Schedule for Children-Revised, Multidimensional Anxiety Scale for Children, Revised Child Anxiety and Depression Scale, Revised Children's Manifest Anxiety Scale, Mood and Feelings Questionnaire, and Disruptive Behavior Rating Scale), which may make them suitable in cross-cultural comparative studies. The remainder of the scales either showed weak or outright lack of measurement invariance. This review showed only limited testing for measurement invariance across cultural groups of scales for pediatric psychopathology, with evidence of cross-cultural validity for only a few scales. This study also revealed a need to improve practices of statistical analysis reporting in testing measurement invariance. Implications for future research are discussed.

  1. Validation of the G.LAB MD2200 wrist blood pressure monitor according to the European Society of Hypertension, the British Hypertension Society, and the International Organization for Standardization Protocols.

    PubMed

    Liu, Ze-Yu; Zhang, Qing-Han; Ye, Xiao-Lei; Liu, Da-Peng; Cheng, Kang; Zhang, Chun-Hai; Wan, Yi

    2017-04-01

    To validate the G.LAB MD2200 automated wrist blood pressure (BP) monitors according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010, the British Hypertension Society (BHS), and the International Organization for Standardization (ISO) 81060-2:2013 protocols. The device was assessed on 33 participants according to the ESH requirements and was then tested on 85 participants according to the BHS and ISO 81060-2:2013 criteria. The validation procedures and data analysis followed the protocols precisely. The G.LAB MD2200 devices passed all parts of ESH-IP revision 2010 for both systolic and diastolic BP, with a device-observer difference of 2.15±5.51 and 1.51±5.16 mmHg, respectively. The device achieved A/A grading for the BHS protocol and it also fulfilled the criteria of ISO 81060-2:2013, with mean differences of systolic and diastolic BP between the device and the observer of 2.19±5.21 and 2.11±4.70 mmHg, respectively. The G.LAB MD2200 automated wrist BP monitor passed the ESH-IP revision 2010 and the ISO 81060-2:2013 protocol, and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  2. The Depressive Experiences Questionnaire: validity and psychological correlates in a clinical sample.

    PubMed

    Riley, W T; McCranie, E W

    1990-01-01

    This study sought to compare the original and revised scoring systems of the Depressive Experiences Questionnaire (DEQ) and to assess the construct validity of the Dependent and Self-Critical subscales of the DEQ in a clinically depressed sample. Subjects were 103 depressed inpatients who completed the DEQ, the Beck Depression Inventory (BDI), the Hopelessness Scale, the Automatic Thoughts Questionnaire (ATQ), the Rathus Assertiveness Schedule (RAS), and the Minnesota Multiphasic Personality Inventory (MMPI). The original and revised scoring systems of the DEQ evidenced good concurrent validity for each factor scale, but the revised system did not sufficiently discriminate dependent and self-critical dimensions. Using the original scoring system, self-criticism was significantly and positively related to severity of depression, whereas dependency was not, particularly for males. Factor analysis of the DEQ scales and the other scales used in this study supported the dependent and self-critical dimensions. For men, the correlation of the DEQ with the MMPI scales indicated that self-criticism was associated with psychotic symptoms, hostility/conflict, and a distress/exaggerated response set, whereas dependency did not correlate significantly with any MMPI scales. Females, however, did not exhibit a differential pattern of correlations between either the Dependency or the Self-Criticism scales and the MMPI. These findings suggest possible gender differences in the clinical characteristics of male and female dependent and self-critical depressive subtypes.

  3. Naval sensor data database (NSDD)

    NASA Astrophysics Data System (ADS)

    Robertson, Candace J.; Tubridy, Lisa H.

    1999-08-01

    The Naval Sensor Data database (NSDD) is a multi-year effort to archive, catalogue, and disseminate data from all types of sensors to the mine warfare, signal and image processing, and sensor development communities. The purpose is to improve and accelerate research and technology. Providing performers with the data required to develop and validate improvements in hardware, simulation, and processing will foster advances in sensor and system performance. The NSDD will provide a centralized source of sensor data in its associated ground truth, which will support an improved understanding will be benefited in the areas of signal processing, computer-aided detection and classification, data compression, data fusion, and geo-referencing, as well as sensor and sensor system design.

  4. Validation of the thermal code of RadTherm-IR, IR-Workbench, and F-TOM

    NASA Astrophysics Data System (ADS)

    Schwenger, Frédéric; Grossmann, Peter; Malaplate, Alain

    2009-05-01

    System assessment by image simulation requires synthetic scenarios that can be viewed by the device to be simulated. In addition to physical modeling of the camera, a reliable modeling of scene elements is necessary. Software products for modeling of target data in the IR should be capable of (i) predicting surface temperatures of scene elements over a long period of time and (ii) computing sensor views of the scenario. For such applications, FGAN-FOM acquired the software products RadTherm-IR (ThermoAnalytics Inc., Calumet, USA; IR-Workbench (OKTAL-SE, Toulouse, France). Inspection of the accuracy of simulation results by validation is necessary before using these products for applications. In the first step of validation, the performance of both "thermal solvers" was determined through comparison of the computed diurnal surface temperatures of a simple object with the corresponding values from measurements. CUBI is a rather simple geometric object with well known material parameters which makes it suitable for testing and validating object models in IR. It was used in this study as a test body. Comparison of calculated and measured surface temperature values will be presented, together with the results from the FGAN-FOM thermal object code F-TOM. In the second validation step, radiances of the simulated sensor views computed by RadTherm-IR and IR-Workbench will be compared with radiances retrieved from the recorded sensor images taken by the sensor that was simulated. Strengths and weaknesses of the models RadTherm-IR, IR-Workbench and F-TOM will be discussed.

  5. The Inertial Stellar Compass (ISC): A Multifunction, Low Power, Attitude Determination Technology Breakthrough

    NASA Technical Reports Server (NTRS)

    Bauer, Frank H. (Technical Monitor); Dennehy, Neil; Gambino, Joel; Maynard, Andrew; Brady, T.; Buckley, S.; Zinchuk, J.

    2003-01-01

    The Inertial Stellar Compass (ISC) is a miniature, low power, stellar inertial attitude determination system with an accuracy of better than 0.1 degree (1 sigma) in three axes. The ISC consumes only 3.5 Watts of power and is contained in a 2.5 kg package. With its embedded on-board processor, the ISC provides attitude quaternion information and has Lost-in-Space (LIS) initialization capability. The attitude accuracy and LIS capability are provided by combining a wide field of view Active Pixel Sensor (APS) star camera and Micro- ElectroMechanical System (MEMS) inertial sensor information in an integrated sensor system. The performance and small form factor make the ISC a useful sensor for a wide range of missions. In particular, the ISC represents an enabling, fully integrated, micro-satellite attitude determination system. Other applications include using the ISC as a single sensor solution for attitude determination on medium performance spacecraft and as a bolt on independent safe-hold sensor or coarse acquisition sensor for many other spacecraft. NASA's New Millennium Program (NMP) has selected the ISC technology for a Space Technology 6 (ST6) flight validation experiment scheduled for 2004. NMP missions, such a s ST6, are intended to validate advanced technologies that have not flown in space in order to reduce the risk associated with their infusion into future NASA missions. This paper describes the design, operation, and performance of the ISC and outlines the technology validation plan. A number of mission applications for the ISC technology are highlighted, both for the baseline ST6 ISC configuration and more ambitious applications where ISC hardware and software modifications would be required. These applications demonstrate the wide range of Space and Earth Science missions that would benefit from infusion of the ISC technology.

  6. Using the Depression Anxiety Stress Scale 21 (DASS-21) across cultures.

    PubMed

    Oei, Tian P S; Sawang, Sukanlaya; Goh, Yong Wah; Mukhtar, Firdaus

    2013-01-01

    The DASS-21 is a well-established instrument for measuring depression, anxiety, and stress with good reliability and validity reported from Hispanic American, British, and Australian adults. However, the lack of appropriate validation among Asian populations continues to pose concerns over the use of DASS-21 in Asian samples. Cultural variation may influence the individual's experience and emotional expression. Thus, when researchers and practitioners employ Western-based assessments with Asian populations by directly translating them without an appropriate validation, the process can be challenging. We conducted a series of rigorous statistical tests and minimized any potential confounds from the demographic information. Following factor analyses, we performed multigroup analysis across six nations to demonstrate consistency of our findings. The advantages of this revised DASS-18 stress scale are twofold. First, it possesses fewer items, which results in a cleaner factorial structure. Second, it has a smaller interfactor correlation. With these justifications, the revised DASS-18 stress scale is potentially more suitable for Asian populations. Nonetheless, given limitations, findings should be considered preliminary.

  7. A Validation Study of the Japanese Version of the Addenbrooke's Cognitive Examination-Revised

    PubMed Central

    dos Santos Kawata, Kelssy Hitomi; Hashimoto, Ryusaku; Nishio, Yoshiyuki; Hayashi, Atsuko; Ogawa, Nanayo; Kanno, Shigenori; Hiraoka, Kotaro; Yokoi, Kayoko; Iizuka, Osamu; Mori, Etsuro

    2012-01-01

    The aim of this study was to validate the Japanese version of the Addenbrooke's Cognitive Examination-Revised (ACE-R) [Mori: Japanese Edition of Hodges JR's Cognitive Assessment for Clinicians, 2010] designed to detect dementia, and to compare its diagnostic accuracy with that of the Mini-Mental State Examination. The ACE-R was administered to 85 healthy individuals and 126 patients with dementia. The reliability assessment revealed a strong correlation in both groups. The internal consistency was excellent (α-coefficient = 0.88). Correlation with the Clinical Dementia Rating sum of boxes score was significant (rs = −0.61, p < 0.001). The area under the curve was 0.98 for the ACE-R and 0.96 for the Mini-Mental State Examination. The cut-off score of 80 showed a sensitivity of 94% and a specificity of 94%. Like the original ACE-R and the versions designed for other languages, the Japanese version of the ACE-R is a reliable and valid test for the detection of dementia. PMID:22619659

  8. The Development of Statistics Textbook Supported with ICT and Portfolio-Based Assessment

    NASA Astrophysics Data System (ADS)

    Hendikawati, Putriaji; Yuni Arini, Florentina

    2016-02-01

    This research was development research that aimed to develop and produce a Statistics textbook model that supported with information and communication technology (ICT) and Portfolio-Based Assessment. This book was designed for students of mathematics at the college to improve students’ ability in mathematical connection and communication. There were three stages in this research i.e. define, design, and develop. The textbooks consisted of 10 chapters which each chapter contains introduction, core materials and include examples and exercises. The textbook developed phase begins with the early stages of designed the book (draft 1) which then validated by experts. Revision of draft 1 produced draft 2 which then limited test for readability test book. Furthermore, revision of draft 2 produced textbook draft 3 which simulated on a small sample to produce a valid model textbook. The data were analysed with descriptive statistics. The analysis showed that the Statistics textbook model that supported with ICT and Portfolio-Based Assessment valid and fill up the criteria of practicality.

  9. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†

    PubMed Central

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.

    2015-01-01

    Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra-articular disorder (sensitivity of 0.80 and specificity of 0.97). Diagnostic criteria for other common intra-articular disorders lack adequate validity for clinical diagnoses but can be used for screening purposes. Inter-examiner reliability for the clinical assessment associated with the validated DC/TMD criteria for pain-related TMD is excellent (kappa ≥ 0.85). Finally, a comprehensive classification system that includes both the common and less common TMD is also presented. The Axis II protocol retains selected original RDC/TMD screening instruments augmented with new instruments to assess jaw function as well as behavioral and additional psychosocial factors. The Axis II protocol is divided into screening and comprehensive self-report instrument sets. The screening instruments’ 41 questions assess pain intensity, pain-related disability, psychological distress, jaw functional limitations, and parafunctional behaviors, and a pain drawing is used to assess locations of pain. The comprehensive instruments, composed of 81 questions, assess in further detail jaw functional limitations and psychological distress as well as additional constructs of anxiety and presence of comorbid pain conditions. Conclusion The recommended evidence-based new DC/TMD protocol is appropriate for use in both clinical and research settings. More comprehensive instruments augment short and simple screening instruments for Axis I and Axis II. These validated instruments allow for identification of patients with a range of simple to complex TMD presentations. PMID:24482784

  10. Flight Test 4 Preliminary Results: NASA Ames SSI

    NASA Technical Reports Server (NTRS)

    Isaacson, Doug; Gong, Chester; Reardon, Scott; Santiago, Confesor

    2016-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements as well as the safety substantiation and end-to-end assessment of DAA system performance. The Unmanned Aircraft System (UAS) Integration into the National Airspace System (NAS) Project conducted flight test program, referred to as Flight Test 4, at Armstrong Flight Research Center from April -June 2016. Part of the test flights were dedicated to the NASA Ames-developed Detect and Avoid (DAA) System referred to as JADEM (Java Architecture for DAA Extensibility and Modeling). The encounter scenarios, which involved NASA's Ikhana UAS and a manned intruder aircraft, were designed to collect data on DAA system performance in real-world conditions and uncertainties with four different surveillance sensor systems. Flight test 4 has four objectives: (1) validate DAA requirements in stressing cases that drive MOPS requirements, including: high-speed cooperative intruder, low-speed non-cooperative intruder, high vertical closure rate encounter, and Mode CS-only intruder (i.e. without ADS-B), (2) validate TCASDAA alerting and guidance interoperability concept in the presence of realistic sensor, tracking and navigational errors and in multiple-intruder encounters against both cooperative and non-cooperative intruders, (3) validate Well Clear Recovery guidance in the presence of realistic sensor, tracking and navigational errors, and (4) validate DAA alerting and guidance requirements in the presence of realistic sensor, tracking and navigational errors. The results will be presented at RTCA Special Committee 228 in support of final verification and validation of the DAA MOPS.

  11. Review of Portable and Low-Cost Sensors for the Ambient Air Monitoring of Benzene and Other Volatile Organic Compounds

    PubMed Central

    Kok, Gertjan; Persijn, Stefan; Sauerwald, Tilman

    2017-01-01

    This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) and portable on-line measuring devices as for example sensor arrays. The bibliographic collection includes the following topics: sensor description, field of application at fixed sites, indoor and ambient air monitoring, range of concentration levels and limit of detection in air, model descriptions of the phenomena involved in the sensor detection process, gaseous interference selectivity of sensors in complex VOC matrix, validation data in lab experiments and under field conditions. PMID:28657595

  12. Review of Portable and Low-Cost Sensors for the Ambient Air Monitoring of Benzene and Other Volatile Organic Compounds.

    PubMed

    Spinelle, Laurent; Gerboles, Michel; Kok, Gertjan; Persijn, Stefan; Sauerwald, Tilman

    2017-06-28

    This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) and portable on-line measuring devices as for example sensor arrays. The bibliographic collection includes the following topics: sensor description, field of application at fixed sites, indoor and ambient air monitoring, range of concentration levels and limit of detection in air, model descriptions of the phenomena involved in the sensor detection process, gaseous interference selectivity of sensors in complex VOC matrix, validation data in lab experiments and under field conditions.

  13. Development of a low-cost soil moisture sensor for in-situ data collection by citizen scientists

    NASA Astrophysics Data System (ADS)

    Rajasekaran, E.; Jeyaram, R.; Lohrli, C.; Das, N.; Podest, E.; Hovhannesian, H.; Fairbanks, G.

    2017-12-01

    Soil moisture (SM) is identified as an Essential Climate Variable and it exerts a strong influence on agriculture, hydrology and land-atmosphere interaction. The aim of this project is to develop an affordable (low-cost), durable, and user-friendly, sensor and an associated mobile app to measure in-situ soil moisture by the citizen scientists or any K-12 students. The sensor essentially measures the electrical resistance between two metallic rods and the resistance is converted into SM based on soil specific calibration equations. The sensor is controlled by a micro-controller (Arduino) and a mobile app (available both for iOS and Android) reads the resistance from the micro-controller and converts it into SM for the soil type selected by the user. Extensive laboratory tests are currently being carried out to standardize the sensor and to calibrate the sensor for various soil types. The sensor will also be tested during field campaigns and recalibrated for field conditions. In addition to the development of the sensor and the mobile app, supporting documentation and videos are also being developed that show the step-by-step process of building the sensor from scratch and measurement protocols. Initial laboratory calibration and validation of the prototype suggested that the sensor is able to satisfactorily measure SM for sand, loam, sandy loam, sandy clay loam type of soils. The affordable and simple sensor will help citizen scientists to understand the dynamics of SM at their site and the in-situ data will further be utilized for validation of the satellite observations from the SMAP mission.

  14. Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

    NASA Astrophysics Data System (ADS)

    Klepper, C. C.; Biewer, T. M.; Marcus, C.; Andrew, P.; Gardner, W. L.; Graves, V. B.; Hughes, S.

    2017-10-01

    The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for \\textasciitilde 1 s response time from the sensor cluster [1].

  15. Initial Validation of NDVI time seriesfrom AVHRR, VEGETATION, and MODIS

    NASA Technical Reports Server (NTRS)

    Morisette, Jeffrey T.; Pinzon, Jorge E.; Brown, Molly E.; Tucker, Jim; Justice, Christopher O.

    2004-01-01

    The paper will address Theme 7: Multi-sensor opportunities for VEGETATION. We present analysis of a long-term vegetation record derived from three moderate resolution sensors: AVHRR, VEGETATION, and MODIS. While empirically based manipulation can ensure agreement between the three data sets, there is a need to validate the series. This paper uses atmospherically corrected ETM+ data available over the EOS Land Validation Core Sites as an independent data set with which to compare the time series. We use ETM+ data from 15 globally distributed sites, 7 of which contain repeat coverage in time. These high-resolution data are compared to the values of each sensor by spatially aggregating the ETM+ to each specific sensors' spatial coverage. The aggregated ETM+ value provides a point estimate for a specific site on a specific date. The standard deviation of that point estimate is used to construct a confidence interval for that point estimate. The values from each moderate resolution sensor are then evaluated with respect to that confident interval. Result show that AVHRR, VEGETATION, and MODIS data can be combined to assess temporal uncertainties and address data continuity issues and that the atmospherically corrected ETM+ data provide an independent source with which to compare that record. The final product is a consistent time series climate record that links historical observations to current and future measurements.

  16. Fiber Optic Thermo-Hygrometers for Soil Moisture Monitoring.

    PubMed

    Leone, Marco; Principe, Sofia; Consales, Marco; Parente, Roberto; Laudati, Armando; Caliro, Stefano; Cutolo, Antonello; Cusano, Andrea

    2017-06-20

    This work deals with the fabrication, prototyping, and experimental validation of a fiber optic thermo-hygrometer-based soil moisture sensor, useful for rainfall-induced landslide prevention applications. In particular, we recently proposed a new generation of fiber Bragg grating (FBGs)-based soil moisture sensors for irrigation purposes. This device was realized by integrating, inside a customized aluminum protection package, a FBG thermo-hygrometer with a polymer micro-porous membrane. Here, we first verify the limitations, in terms of the volumetric water content (VWC) measuring range, of this first version of the soil moisture sensor for its exploitation in landslide prevention applications. Successively, we present the development, prototyping, and experimental validation of a novel, optimized version of a soil VWC sensor, still based on a FBG thermo-hygrometer, but able to reliably monitor, continuously and in real-time, VWC values up to 37% when buried in the soil.

  17. Fiber Optic Thermo-Hygrometers for Soil Moisture Monitoring

    PubMed Central

    Leone, Marco; Principe, Sofia; Consales, Marco; Parente, Roberto; Laudati, Armando; Caliro, Stefano; Cutolo, Antonello; Cusano, Andrea

    2017-01-01

    This work deals with the fabrication, prototyping, and experimental validation of a fiber optic thermo-hygrometer-based soil moisture sensor, useful for rainfall-induced landslide prevention applications. In particular, we recently proposed a new generation of fiber Bragg grating (FBGs)-based soil moisture sensors for irrigation purposes. This device was realized by integrating, inside a customized aluminum protection package, a FBG thermo-hygrometer with a polymer micro-porous membrane. Here, we first verify the limitations, in terms of the volumetric water content (VWC) measuring range, of this first version of the soil moisture sensor for its exploitation in landslide prevention applications. Successively, we present the development, prototyping, and experimental validation of a novel, optimized version of a soil VWC sensor, still based on a FBG thermo-hygrometer, but able to reliably monitor, continuously and in real-time, VWC values up to 37% when buried in the soil. PMID:28632172

  18. Revision, Criterion Validity, and Multi-group Assessment of the Reactions to Homosexuality Scale

    PubMed Central

    Smolenski, Derek J.; Diamond, Pamela M.; Ross, Michael W.; Simon Rosser, B. R.

    2010-01-01

    Internalized homonegativity encompasses negative attitudes toward one’s own sexual orientation, and is associated with negative mental and physical health outcomes. The Reactions to Homosexuality scale (Ross & Rosser, 1996), an instrument used to measure internalized homonegativity, has been criticized for including content irrelevant to the construct of internalized homonegativity. We revised the scale using exploratory and confirmatory factor analyses, and identified a seven-item, three-factor reduced version that demonstrated measurement invariance across racial/ethnic categorizations and between English and Spanish versions. We also investigated criterion validity by estimating correlations with hypothesized outcomes associated with outness, relationship status, sexual orientation, and gay community affiliation. The evidence of measurement invariance suggests that this scale is appropriate for pluralistic treatment or study groups. PMID:20954058

  19. Further empirical data on the psychoeducational profile-revised (PEP-R): reliability and validation with the Vineland adaptive behavior scales.

    PubMed

    Villa, Susanna; Micheli, Enrico; Villa, Laura; Pastore, Valentina; Crippa, Alessandro; Molteni, Massimo

    2010-03-01

    The PEP-R (psychoeducational profile revised) is an instrument that has been used in many countries to assess abilities and formulate treatment programs for children with autism and related developmental disorders. To the end to provide further information on the PEP-R's psychometric properties, a large sample (N = 137) of children presenting Autistic Disorder symptoms under the age of 12 years, including low-functioning individuals, was examined. Results yielded data of interest especially in terms of: Cronbach's alpha, interrater reliability, and validation with the Vineland Adaptive Behavior Scales. These findings help complete the instrument's statistical description and augment its usefulness, not only in designing treatment programs for these individuals, but also as an instrument for verifying the efficacy of intervention.

  20. Validation of the Omron M3 Intellisense (HEM-7051-E) upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010 in a stage 3-5 chronic kidney disease population.

    PubMed

    Akpolat, Tekin; Erdem, Emre; Aydogdu, Türkan

    2012-01-01

    Encouragement of home blood pressure (BP) monitoring has a great potential to improve hypertension control rates. The purpose of this study was to test validation of the Omron M3 Intellisense (HEM-7051-E) upper arm BP measuring monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP2) in stage 3-5 chronic kidney disease (CKD) patients. 66 patients having CKD stage 3-5 were included in the study. Nine consecutive measurements were made according to the ESH-IP2 protocol. The Omron M3 Intellisense device fulfills the validation criteria of the ESH-IP2 for stage 3-5 CKD patients. Although arterial stiffness can affect accurate BP measurement, there are limited data regarding the use of automated oscillometric devices in CKD. To our knowledge, this is the first study investigating validation of an oscillometric device in stage 3-5 predialysis CKD patients. This study validates the Omron M3 Intellisense upper arm device for stage 3-5 CKD patients. New validation studies investigating other oscillometric sphygmomanometers for CKD patients and involvement of nephrologists in these studies have great potential to increase patient care in CKD. Copyright © 2011 S. Karger AG, Basel.

  1. Validation of ocean color sensors using a profiling hyperspectral radiometer

    NASA Astrophysics Data System (ADS)

    Ondrusek, M. E.; Stengel, E.; Rella, M. A.; Goode, W.; Ladner, S.; Feinholz, M.

    2014-05-01

    Validation measurements of satellite ocean color sensors require in situ measurements that are accurate, repeatable and traceable enough to distinguish variability between in situ measurements and variability in the signal being observed on orbit. The utility of using a Satlantic Profiler II equipped with HyperOCR radiometers (Hyperpro) for validating ocean color sensors is tested by assessing the stability of the calibration coefficients and by comparing Hyperpro in situ measurements to other instruments and between different Hyperpros in a variety of water types. Calibration and characterization of the NOAA Satlantic Hyperpro instrument is described and concurrent measurements of water-leaving radiances conducted during cruises are presented between this profiling instrument and other profiling, above-water and moored instruments. The moored optical instruments are the US operated Marine Optical BuoY (MOBY) and the French operated Boussole Buoy. In addition, Satlantic processing versions are described in terms of accuracy and consistency. A new multi-cast approach is compared to the most commonly used single cast method. Analysis comparisons are conducted in turbid and blue water conditions. Examples of validation matchups with VIIRS ocean color data are presented. With careful data collection and analysis, the Satlantic Hyperpro profiling radiometer has proven to be a reliable and consistent tool for satellite ocean color validation.

  2. Double-Pulsed 2-Micrometer Lidar Validation for Atmospheric CO2 Measurements

    NASA Technical Reports Server (NTRS)

    Singh, Upendra N.; Refaat, Tamer F.; Yu, Jirong; Petros, Mulugeta; Remus, Ruben

    2015-01-01

    A double-pulsed, 2-micron Integrated Path Differential Absorption (IPDA) lidar instrument for atmospheric carbon dioxide (CO2) measurements is successfully developed at NASA Langley Research Center (LaRC). Based on direct detection technique, the instrument can be operated on ground or onboard a small aircraft. Key features of this compact, rugged and reliable IPDA lidar includes high transmitted laser energy, wavelength tuning, switching and locking, and sensitive detection. As a proof of concept, the IPDA ground and airborne CO2 measurement and validation will be presented. IPDA lidar CO2 measurements ground validation were conducted at NASA LaRC using hard targets and a calibrated in-situ sensor. Airborne validation, conducted onboard the NASA B-200 aircraft, included CO2 plum detection from power stations incinerators, comparison to in-flight CO2 in-situ sensor and comparison to air sampling at different altitude conducted by NOAA at the same site. Airborne measurements, spanning for 20 hours, were obtained from different target conditions. Ground targets included soil, vegetation, sand, snow and ocean. In addition, cloud slicing was examined over the ocean. These flight validations were conducted at different altitudes, up to 7 km, with different wavelength controlled weighing functions. CO2 measurement results agree with modeling conducted through the different sensors, as will be discussed.

  3. Additions and corrections to the check list of the Noctuoidea (Insecta, Lepidoptera) of North America north of Mexico

    PubMed Central

    Lafontaine, J. Donald; Schmidt, B. Christian

    2011-01-01

    Abstract A total of 115 additions and corrections are listed and discussed for the check list of the Noctuoidea of North America north of Mexico published in 2010. Thirty-two of these are changes in authorship and/or date of publication or spelling. Taxonomic changes are 33 new or revised synonymies, three new combinations, and six revisions in status from synonymy to valid species. PMID:22207802

  4. Effect of Replacing Race with Apolipoprotein L1 Genotype in Calculation of Kidney Donor Risk Index

    PubMed Central

    Julian, B. A.; Gaston, R. S.; Brown, W. M.; Reeves-Daniel, A. M.; Israni, A. K.; Schladt, D. P.; Pastan, S. O.; Mohan, S.; Freedman, B. I.; Divers, J.

    2016-01-01

    Renal allografts from deceased African Americans with two apolipoprotein L1 gene (APOL1) renal-risk variants fail sooner than kidneys from donors with fewer variants. Kidney Donor Risk Index (KDRI) was developed to evaluate organ offers by predicting allograft longevity and includes African American race as a risk factor. Substituting APOL1 genotype for race may refine the KDRI. For 622 deceased African American kidney donors, we applied 10-fold cross-validation approach to estimate contribution of APOL1 variants to a revised KDRI. Cross-validation was repeated 10,000 times to generate distribution of effect size associated with APOL1 genotype. Average effect size was used to derive the revised KDRI weighting. Mean current-KDRI score for all donors was 1.4930 versus mean revised-KDRI score 1.2518 for 529 donors with 0/1 variant and 1.8527 for 93 donors with 2 variants. Original and revised KDRIs had comparable survival prediction errors after transplantation, but the spread in Kidney Donor Profile Index based on presence/absence of 2 APOL1 variants was 37 percentage points. Replacing donor race with APOL1 genotype in KDRI better defines risk associated with kidneys transplanted from deceased African American donors, substantially improves KDRI score for 85-90% of kidneys offered, and enhances the link between donor quality and recipient need. PMID:27862962

  5. Developing Maritime Thematic Expressions on English Reading Materials Used In Indonesia: Junior High School Context

    NASA Astrophysics Data System (ADS)

    Syahdan; Lusandi, Budi

    2018-05-01

    Indonesia is a maritime country with the largest islands in the world covering more than seventeen thousands islands. This wealth should be wisely explored for all their advantages. Also, all parties should take responsibility to inherit values embedded in the wealth. This study is a Research and Development focusing at developing English worksheet materials in the theme of Maritime Thematic Expressions. Specifically, it aimed at identifying initial contents of the English worksheet, describing the development of worksheet materials and justifying contents of worksheet materials in facilitating the students’ needs in reading English materials. The flow of this R&D refers to Sugiono’s model that includes analyzing data, collecting data, designing materials, validating material, revising the material, piloting products, revising the material, piloting materials, revising the material and material development. The development of this material adjusted to the needs of syllabus and national strategic issues in maritime that were coined with students of Junior High School Terbuka Pekanbaru. The worsksheet development has been revised and validated by some experts of curriculum and linguistics. This material has also been piloted by the English teacher to determine of the students’ ability in comprehending the materials. Based on the results of this development, it can be concluded that the materials development were relevant with the standard competence and basic competence in syllabus of the students’ reading skill in Junior High School Terbuka Pekanbaru.

  6. Validation of the revised Mystical Experience Questionnaire in experimental sessions with psilocybin.

    PubMed

    Barrett, Frederick S; Johnson, Matthew W; Griffiths, Roland R

    2015-11-01

    The 30-item revised Mystical Experience Questionnaire (MEQ30) was previously developed within an online survey of mystical-type experiences occasioned by psilocybin-containing mushrooms. The rated experiences occurred on average eight years before completion of the questionnaire. The current paper validates the MEQ30 using data from experimental studies with controlled doses of psilocybin. Data were pooled and analyzed from five laboratory experiments in which participants (n=184) received a moderate to high oral dose of psilocybin (at least 20 mg/70 kg). Results of confirmatory factor analysis demonstrate the reliability and internal validity of the MEQ30. Structural equation models demonstrate the external and convergent validity of the MEQ30 by showing that latent variable scores on the MEQ30 positively predict persisting change in attitudes, behavior, and well-being attributed to experiences with psilocybin while controlling for the contribution of the participant-rated intensity of drug effects. These findings support the use of the MEQ30 as an efficient measure of individual mystical experiences. A method to score a "complete mystical experience" that was used in previous versions of the mystical experience questionnaire is validated in the MEQ30, and a stand-alone version of the MEQ30 is provided for use in future research. © The Author(s) 2015.

  7. Validation of the revised Mystical Experience Questionnaire in experimental sessions with psilocybin

    PubMed Central

    Barrett, Frederick S; Johnson, Matthew W; Griffiths, Roland R

    2016-01-01

    The 30-item revised Mystical Experience Questionnaire (MEQ30) was previously developed within an online survey of mystical-type experiences occasioned by psilocybin-containing mushrooms. The rated experiences occurred on average eight years before completion of the questionnaire. The current paper validates the MEQ30 using data from experimental studies with controlled doses of psilocybin. Data were pooled and analyzed from five laboratory experiments in which participants (n=184) received a moderate to high oral dose of psilocybin (at least 20 mg/70 kg). Results of confirmatory factor analysis demonstrate the reliability and internal validity of the MEQ30. Structural equation models demonstrate the external and convergent validity of the MEQ30 by showing that latent variable scores on the MEQ30 positively predict persisting change in attitudes, behavior, and well-being attributed to experiences with psilocybin while controlling for the contribution of the participant-rated intensity of drug effects. These findings support the use of the MEQ30 as an efficient measure of individual mystical experiences. A method to score a “complete mystical experience” that was used in previous versions of the mystical experience questionnaire is validated in the MEQ30, and a stand-alone version of the MEQ30 is provided for use in future research. PMID:26442957

  8. The reliability and validity of a Japanese version of symptom checklist 90 revised

    PubMed Central

    Tomioka, Mitsunao; Shimura, Midori; Hidaka, Mikio; Kubo, Chiharu

    2008-01-01

    Objective To examine the validity and reliability of a Japanese version of the Symptom Checklist 90 Revised (SCL-90-R (J)). Methods The English SCL-90-R was translated to Japanese and the Japanese version confirmed by back-translation. To determine the factor validity and internal consistency of the nine primary subscales, 460 people from the community completed SCL-90-R(J). Test-retest reliability was examined for 104 outpatients and 124 healthy undergraduate students. The convergent-discriminant validity was determined for 80 inpatients who replied to both SCL-90-R(J) and the Minnesota Multiphasic Personality Inventory (MMPI). Results The correlation coefficients between the nine primary subscales and items were .26 to .78. Cronbach's alpha coefficients were from .76 (Phobic Anxiety) to .86 (Interpersonal Sensitivity). Pearson's correlation coefficients between test-retest scores were from .81 (Psychoticism) to .90 (Somatization) for the outpatients and were from .64 (Phobic Anxiety) to .78 (Paranoid Ideation) for the students. Each of the nine primary subscales correlated well with their corresponding constructs in the MMPI. Conclusion We confirmed the validity and reliability of SCL-90-R(J) for the measurement of individual distress. The nine primary subscales were consistent with the items of the original English version. PMID:18957078

  9. A French validation study of the Coma Recovery Scale-Revised (CRS-R).

    PubMed

    Schnakers, Caroline; Majerus, Steve; Giacino, Joseph; Vanhaudenhuyse, Audrey; Bruno, Marie-Aurelie; Boly, Melanie; Moonen, Gustave; Damas, Pierre; Lambermont, Bernard; Lamy, Maurice; Damas, Francois; Ventura, Manfredi; Laureys, Steven

    2008-09-01

    The aim of the present study was to explore the concurrent validity, inter-rater agreement and diagnostic sensitivity of a French adaptation of the Coma Recovery Scale-Revised (CRS-R) as compared to other coma scales such as the Glasgow Coma Scale (GCS), the Full Outline of UnResponsiveness scale (FOUR) and the Wessex Head Injury Matrix (WHIM). Multi-centric prospective study. To test concurrent validity and diagnostic sensitivity, the four behavioural scales were administered in a randomized order in 77 vegetative and minimally conscious patients. Twenty-four clinicians with different professional backgrounds, levels of expertise and CRS-R experience were recruited to assess inter-rater agreement. Good concurrent validity was obtained between the CRS-R and the three other standardized behavioural scales. Inter-rater reliability for the CRS-R total score and sub-scores was good, indicating that the scale yields reproducible findings across examiners and does not appear to be systematically biased by profession, level of expertise or CRS-R experience. Finally, the CRS-R demonstrated a significantly higher sensitivity to detect MCS patients, as compared to the GCS, the FOUR and the WHIM. The results show that the French version of the CRS-R is a valid and sensitive scale which can be used in severely brain damaged patients by all members of the medical staff.

  10. Reliability and validity of electrothermometers and associated thermocouples.

    PubMed

    Jutte, Lisa S; Knight, Kenneth L; Long, Blaine C

    2008-02-01

    Examine thermocouple model uncertainty (reliability+validity). First, a 3x3 repeated measures design with independent variables electrothermometers and thermocouple model. Second, a 1x3 repeated measures design with independent variable subprobe. Three electrothermometers, 3 thermocouple models, a multi-sensor probe and a mercury thermometer measured a stable water bath. Temperature and absolute temperature differences between thermocouples and a mercury thermometer. Thermocouple uncertainty was greater than manufactures'claims. For all thermocouple models, validity and reliability were better in the Iso-Themex than the Datalogger, but there were no practical differences between models within an electrothermometers. Validity of multi-sensor probes and thermocouples within a probe were not different but were greater than manufacturers'claims. Reliability of multiprobes and thermocouples within a probe were within manufacturers claims. Thermocouple models vary in reliability and validity. Scientists should test and report the uncertainty of their equipment rather than depending on manufactures' claims.

  11. Using smartphone pressure sensors to measure vertical velocities of elevators, stairways, and drones

    NASA Astrophysics Data System (ADS)

    Monteiro, Martín; Martí, Arturo C.

    2017-01-01

    We measure the vertical velocities of elevators, pedestrians climbing stairs, and drones (flying unmanned aerial vehicles), by means of smartphone pressure sensors. The barometric pressure obtained with the smartphone is related to the altitude of the device via the hydrostatic approximation. From the altitude values, vertical velocities are derived. The approximation considered is valid in the first hundred meters of the inner layers of the atmosphere. In addition to pressure, acceleration values were also recorded using the built-in accelerometer. Numerical integration was performed, obtaining both vertical velocity and altitude. We show that data obtained using the pressure sensor is significantly less noisy than that obtained using the accelerometer. Error accumulation is also evident in the numerical integration of the acceleration values. In the proposed experiments, the pressure sensor also outperforms GPS, because this sensor does not receive satellite signals indoors and, in general, the operating frequency is considerably lower than that of the pressure sensor. In the cases in which it is possible, comparison with reference values taken from the architectural plans of buildings validates the results obtained using the pressure sensor. This proposal is ideally performed as an external or outreach activity with students to gain insight about fundamental questions in mechanics, fluids, and thermodynamics.

  12. Reasoning Activity for Smart Homes Using a Lattice-Based Evidential Structure

    NASA Astrophysics Data System (ADS)

    Liao, Jing; Bi, Yaxin; Nugent, Chris

    This paper explores a revised evidential lattice structure designed for the purposes of activity recognition within Smart Homes. The proposed structure consists of three layers, an object layer, a context layer and an activity layer. These layers can be used to combine the mass functions derived from sensors along with sensor context and can subsequently be used to infer activities. We present the details of configuring the activity recognition process and perform an analysis on the relationship between the number of sensors and the number of layers. We also present the details of an empirical study on two public data sets. The results from this work has demonstrated that the proposed method is capable of correctly detecting activities with a high degree of accuracy (84.27%) with a dataset from MIT [4] and 82.49% with a dataset from the University of Amsterdam[10].

  13. A Virtual Sensor for Online Fault Detection of Multitooth-Tools

    PubMed Central

    Bustillo, Andres; Correa, Maritza; Reñones, Anibal

    2011-01-01

    The installation of suitable sensors close to the tool tip on milling centres is not possible in industrial environments. It is therefore necessary to design virtual sensors for these machines to perform online fault detection in many industrial tasks. This paper presents a virtual sensor for online fault detection of multitooth tools based on a Bayesian classifier. The device that performs this task applies mathematical models that function in conjunction with physical sensors. Only two experimental variables are collected from the milling centre that performs the machining operations: the electrical power consumption of the feed drive and the time required for machining each workpiece. The task of achieving reliable signals from a milling process is especially complex when multitooth tools are used, because each kind of cutting insert in the milling centre only works on each workpiece during a certain time window. Great effort has gone into designing a robust virtual sensor that can avoid re-calibration due to, e.g., maintenance operations. The virtual sensor developed as a result of this research is successfully validated under real conditions on a milling centre used for the mass production of automobile engine crankshafts. Recognition accuracy, calculated with a k-fold cross validation, had on average 0.957 of true positives and 0.986 of true negatives. Moreover, measured accuracy was 98%, which suggests that the virtual sensor correctly identifies new cases. PMID:22163766

  14. Design, fabrication and experimental validation of a novel dry-contact sensor for measuring electroencephalography signals without skin preparation.

    PubMed

    Liao, Lun-De; Wang, I-Jan; Chen, Sheng-Fu; Chang, Jyh-Yeong; Lin, Chin-Teng

    2011-01-01

    In the present study, novel dry-contact sensors for measuring electro-encephalography (EEG) signals without any skin preparation are designed, fabricated by an injection molding manufacturing process and experimentally validated. Conventional wet electrodes are commonly used to measure EEG signals; they provide excellent EEG signals subject to proper skin preparation and conductive gel application. However, a series of skin preparation procedures for applying the wet electrodes is always required and usually creates trouble for users. To overcome these drawbacks, novel dry-contact EEG sensors were proposed for potential operation in the presence or absence of hair and without any skin preparation or conductive gel usage. The dry EEG sensors were designed to contact the scalp surface with 17 spring contact probes. Each probe was designed to include a probe head, plunger, spring, and barrel. The 17 probes were inserted into a flexible substrate using a one-time forming process via an established injection molding procedure. With these 17 spring contact probes, the flexible substrate allows for high geometric conformity between the sensor and the irregular scalp surface to maintain low skin-sensor interface impedance. Additionally, the flexible substrate also initiates a sensor buffer effect, eliminating pain when force is applied. The proposed dry EEG sensor was reliable in measuring EEG signals without any skin preparation or conductive gel usage, as compared with the conventional wet electrodes.

  15. A virtual sensor for online fault detection of multitooth-tools.

    PubMed

    Bustillo, Andres; Correa, Maritza; Reñones, Anibal

    2011-01-01

    The installation of suitable sensors close to the tool tip on milling centres is not possible in industrial environments. It is therefore necessary to design virtual sensors for these machines to perform online fault detection in many industrial tasks. This paper presents a virtual sensor for online fault detection of multitooth tools based on a bayesian classifier. The device that performs this task applies mathematical models that function in conjunction with physical sensors. Only two experimental variables are collected from the milling centre that performs the machining operations: the electrical power consumption of the feed drive and the time required for machining each workpiece. The task of achieving reliable signals from a milling process is especially complex when multitooth tools are used, because each kind of cutting insert in the milling centre only works on each workpiece during a certain time window. Great effort has gone into designing a robust virtual sensor that can avoid re-calibration due to, e.g., maintenance operations. The virtual sensor developed as a result of this research is successfully validated under real conditions on a milling centre used for the mass production of automobile engine crankshafts. Recognition accuracy, calculated with a k-fold cross validation, had on average 0.957 of true positives and 0.986 of true negatives. Moreover, measured accuracy was 98%, which suggests that the virtual sensor correctly identifies new cases.

  16. Design, Fabrication and Experimental Validation of a Novel Dry-Contact Sensor for Measuring Electroencephalography Signals without Skin Preparation

    PubMed Central

    Liao, Lun-De; Wang, I-Jan; Chen, Sheng-Fu; Chang, Jyh-Yeong; Lin, Chin-Teng

    2011-01-01

    In the present study, novel dry-contact sensors for measuring electro-encephalography (EEG) signals without any skin preparation are designed, fabricated by an injection molding manufacturing process and experimentally validated. Conventional wet electrodes are commonly used to measure EEG signals; they provide excellent EEG signals subject to proper skin preparation and conductive gel application. However, a series of skin preparation procedures for applying the wet electrodes is always required and usually creates trouble for users. To overcome these drawbacks, novel dry-contact EEG sensors were proposed for potential operation in the presence or absence of hair and without any skin preparation or conductive gel usage. The dry EEG sensors were designed to contact the scalp surface with 17 spring contact probes. Each probe was designed to include a probe head, plunger, spring, and barrel. The 17 probes were inserted into a flexible substrate using a one-time forming process via an established injection molding procedure. With these 17 spring contact probes, the flexible substrate allows for high geometric conformity between the sensor and the irregular scalp surface to maintain low skin-sensor interface impedance. Additionally, the flexible substrate also initiates a sensor buffer effect, eliminating pain when force is applied. The proposed dry EEG sensor was reliable in measuring EEG signals without any skin preparation or conductive gel usage, as compared with the conventional wet electrodes. PMID:22163929

  17. Revision rates after knee replacement. Cumulative results from worldwide clinical studies versus joint registers.

    PubMed

    Pabinger, C; Berghold, A; Boehler, N; Labek, G

    2013-02-01

    To assess revision rates after knee arthroplasty by comparing the cumulative results from worldwide clinical studies and arthroplasty registers. We hypothesised that the revision rate of all clinical studies of a given implant and register data would not differ significantly. A systematic review of clinical studies in indexed peer-reviewed journals was performed followed by internal and external validation. Parameters for measurement of revision were applied (Revision for any reason, Revisions per 100 observed component years). Register data served as control group. Thirty-six knee arthroplasty systems were identified to meet the inclusion criteria: 21 total knee arthroplasty (TKA) systems, 14 unicondylar knee arthroplasty (UKA) systems, one patello-femoral implant system. For 13 systems (36%), no published study was available that contained revision data. For 17 implants (47%), publications were available dealing with radiographic, surgical or technical details, but power was too weak to compare revision rates at a significant level. Six implant systems (17%) had a significant number of revisions published and were finally analysed. In general, developers report better results than independent users. Studies from developers represent an overproportional share of all observed component years. Register data report overall 10-year revision rates of TKA of 6.2% (range: 4.9-7.8%), rates for UKA are 16.5% (range: 9.7-19.6%). Revision rates of all clinical studies of a given implant do not differ significantly from register data. However, significant differences were found between the revision rates published by developers and register data. Therefore the different data need to be interpreted in the context of the source of the information. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  18. Dynamics, Control, and Fabrication of Micro Embedded Heaters and Sensors for Micro SMA Active Endoscopes

    NASA Astrophysics Data System (ADS)

    Aphanuphong, Sutha

    This research investigates design and control of an active catheter for minimally invasive medical procedures. Microfabrication techniques are developed and several prototypes were constructed. The understanding and analysis results from each design iteration are utilized to improve the overall design and the performance of each revision. An innovative co-fabrication method is explored to simplify the fabrication process and also improve the quality, repeatability, and reliability of the active catheter. This co-fabrication method enables a unique compact integrated heater and sensor film to be directly constructed on a shape memory alloy (SMA) sheet and to be utilized as an outline mask to pattern a micro SMA actuator. There are two functions integrated in the sensor film: heat sources to actuate the micro SMA actuator and sensors to provide temperature and strain of the active catheter to closed-loop control algorithms. Three main aspects are explored in this dissertation: thermal dynamics in the MicroFlex (muF) film and its effect on the sensor capabilities; non-minimum phase behavior and its effect on control performance, and film micro fabrication design and its effect on thermal dynamics. The sensor film developed from this understanding is able to deliver excellent heating and sensing performance with a simple design.

  19. A mid-infrared laser absorption sensor for carbon monoxide and temperature measurements

    NASA Astrophysics Data System (ADS)

    Vanderover, Jeremy

    A mid-infrared (mid-IR) absorption sensor based on quantum cascade laser (QCL) technology has been developed and demonstrated for high-temperature thermometry and carbon monoxide (CO) measurements in combustion environments. The sensor probes the high-intensity fundamental CO ro-vibrational band at 4.6 mum enabling sensitive measurement of CO and temperature at kHz acquisition rates. Because the sensor operates in the mid-IR CO fundamental band it is several orders of magnitude more sensitive than most of the previously developed CO combustion sensors which utilized absorption in the near-IR overtone bands and mature traditional telecommunications-based diode lasers. The sensor has been demonstrated and validated under operation in both scanned-wavelength absorption and wavelength-modulation spectroscopy (WMS) modes in room-temperature gas cell and high-temperature shock tube experiments with known and specified gas conditions. The sensor has also been demonstrated for CO and temperature measurements in an atmospheric premixed ethylene/air McKenna burner flat flame for a range of equivalence ratios (phi = 0.7-1.4). Demonstration of the sensor under scanned-wavelength direct absorption operation was performed in a room-temperature gas cell (297 K and 0.001-1 atm) allowing validation of the line strengths and line shapes predicted by the HITRAN 2004 spectroscopic database. Application of the sensor in scanned-wavelength mode, at 1-2 kHz acquisition bandwidths, to specified high-temperature shock-heated gases (950-3400 K, 1 atm) provided validation of the sensor for measurements under the high-temperature conditions found in combustion devices. The scanned-wavelength shock tube measurements yielded temperature determinations that deviated by only +/-1.2% (1-sigma deviation) with the reflected shock temperatures and CO mole fraction determinations that deviated by that specified CO mole fraction by only +/-1.5% (1-sigma deviation). These deviations are in fact smaller than the estimated uncertainties of 2.5-3% in both sensor determined temperature and CO. Enhancement of the sensor sensitivity can be achieved through use wavelength-modulation spectroscopy (WMS). Similarly, under WMS operation the sensor was applied to room-temperature gas cell (297 K, 0.001-1 atm) measurements, which indicate that the sensor sensitivity in WMS operation is approximately an order-of-magnitude greater than that achieved in scanned-wavelength mode, and high-temperature shock-heated gases (850-3400 K, 1 atm), which validate the sensor for sensitive thermometry at combustion temperatures. In WMS mode the temperature measurements show 1-sigma deviation of +/-1.9% with the reflected shock conditions. High-temperature CO concentration measurements require calibration to scale the measured WMS-2f peak height with a simulated WMS-2 f line shape. However, using single point calibration for each CO containing mixture studied resulted in fairly good agreement (1-sigma deviation of +/-4.2%) between measured and simulated WMS-2f peak height. In other words, CO mole fraction determinations (proportional to peak height) were achieved with deviation of +/-4.2% with specified CO mole fraction. Sensor measurements made at a 1 kHz acquisition bandwidth in an atmospheric pressure ethylene/air flat-flame produced by a McKenna burner for equivalence ratios from 0.7 to 1.4 were in excellent accord with thermocouple measurements and chemical equilibrium predictions for CO based on the thermocouple temperatures for rich conditions. At lean conditions sensor temperature determinations are lower than thermocouple determinations by around 150 K due to the cool flame edge and sensor CO measurements are greater than those predicted by chemical equilibrium due to super-equilibrium CO in the cool flame edge. The CO sensor developed and described herein and validated in room-temperature cell, high-temperature shock tube, and flat-flame burner measurements has potential for a vast array of measurements in combustion, energy, and industrial gas sensing applications. It has unsurpassed sensitivity due to the use of the fundamental CO band at 4.6 mum and provides kHz acquisition bandwidths necessary for high-speed measurements in these systems. This research was directed by Professor Matt Oehlschlaeger and supported by the Office of Naval Research (ONR).

  20. A neural network-based estimator for the mixture ratio of the Space Shuttle Main Engine

    NASA Astrophysics Data System (ADS)

    Guo, T. H.; Musgrave, J.

    1992-11-01

    In order to properly utilize the available fuel and oxidizer of a liquid propellant rocket engine, the mixture ratio is closed loop controlled during main stage (65 percent - 109 percent power) operation. However, because of the lack of flight-capable instrumentation for measuring mixture ratio, the value of mixture ratio in the control loop is estimated using available sensor measurements such as the combustion chamber pressure and the volumetric flow, and the temperature and pressure at the exit duct on the low pressure fuel pump. This estimation scheme has two limitations. First, the estimation formula is based on an empirical curve fitting which is accurate only within a narrow operating range. Second, the mixture ratio estimate relies on a few sensor measurements and loss of any of these measurements will make the estimate invalid. In this paper, we propose a neural network-based estimator for the mixture ratio of the Space Shuttle Main Engine. The estimator is an extension of a previously developed neural network based sensor failure detection and recovery algorithm (sensor validation). This neural network uses an auto associative structure which utilizes the redundant information of dissimilar sensors to detect inconsistent measurements. Two approaches have been identified for synthesizing mixture ratio from measurement data using a neural network. The first approach uses an auto associative neural network for sensor validation which is modified to include the mixture ratio as an additional output. The second uses a new network for the mixture ratio estimation in addition to the sensor validation network. Although mixture ratio is not directly measured in flight, it is generally available in simulation and in test bed firing data from facility measurements of fuel and oxidizer volumetric flows. The pros and cons of these two approaches will be discussed in terms of robustness to sensor failures and accuracy of the estimate during typical transients using simulation data.

  1. A neural network-based estimator for the mixture ratio of the Space Shuttle Main Engine

    NASA Technical Reports Server (NTRS)

    Guo, T. H.; Musgrave, J.

    1992-01-01

    In order to properly utilize the available fuel and oxidizer of a liquid propellant rocket engine, the mixture ratio is closed loop controlled during main stage (65 percent - 109 percent power) operation. However, because of the lack of flight-capable instrumentation for measuring mixture ratio, the value of mixture ratio in the control loop is estimated using available sensor measurements such as the combustion chamber pressure and the volumetric flow, and the temperature and pressure at the exit duct on the low pressure fuel pump. This estimation scheme has two limitations. First, the estimation formula is based on an empirical curve fitting which is accurate only within a narrow operating range. Second, the mixture ratio estimate relies on a few sensor measurements and loss of any of these measurements will make the estimate invalid. In this paper, we propose a neural network-based estimator for the mixture ratio of the Space Shuttle Main Engine. The estimator is an extension of a previously developed neural network based sensor failure detection and recovery algorithm (sensor validation). This neural network uses an auto associative structure which utilizes the redundant information of dissimilar sensors to detect inconsistent measurements. Two approaches have been identified for synthesizing mixture ratio from measurement data using a neural network. The first approach uses an auto associative neural network for sensor validation which is modified to include the mixture ratio as an additional output. The second uses a new network for the mixture ratio estimation in addition to the sensor validation network. Although mixture ratio is not directly measured in flight, it is generally available in simulation and in test bed firing data from facility measurements of fuel and oxidizer volumetric flows. The pros and cons of these two approaches will be discussed in terms of robustness to sensor failures and accuracy of the estimate during typical transients using simulation data.

  2. Synthetic Scene Generation of the Stennis V and V Target Range for the Calibration of Remote Sensing Systems

    NASA Technical Reports Server (NTRS)

    Cao, Chang-Yong; Blonski, Slawomir; Ryan, Robert; Gasser, Jerry; Zanoni, Vicki

    1999-01-01

    The verification and validation (V&V) target range developed at Stennis Space Center is a useful test site for the calibration of remote sensing systems. In this paper, we present a simple algorithm for generating synthetic radiance scenes or digital models of this target range. The radiation propagation for the target in the solar reflective and thermal infrared spectral regions is modeled using the atmospheric radiative transfer code MODTRAN 4. The at-sensor, in-band radiance and spectral radiance for a given sensor at a given altitude is predicted. Software is developed to generate scenes with different spatial and spectral resolutions using the simulated at-sensor radiance values. The radiometric accuracy of the simulation is evaluated by comparing simulated with AVIRIS acquired radiance values. The results show that in general there is a good match between AVIRIS sensor measured and MODTRAN predicted radiance values for the target despite the fact that some anomalies exist. Synthetic scenes provide a cost-effective way for in-flight validation of the spatial and radiometric accuracy of the data. Other applications include mission planning, sensor simulation, and trade-off analysis in sensor design.

  3. The effect of time synchronization of wireless sensors on the modal analysis of structures

    NASA Astrophysics Data System (ADS)

    Krishnamurthy, V.; Fowler, K.; Sazonov, E.

    2008-10-01

    Driven by the need to reduce the installation cost and maintenance cost of structural health monitoring (SHM) systems, wireless sensor networks (WSNs) are becoming increasingly popular. Perfect time synchronization amongst the wireless sensors is a key factor enabling the use of low-cost, low-power WSNs for structural health monitoring applications based on output-only modal analysis of structures. In this paper we present a theoretical framework for analysis of the impact created by time delays in the measured system response on the reconstruction of mode shapes using the popular frequency domain decomposition (FDD) technique. This methodology directly estimates the change in mode shape values based on sensor synchronicity. We confirm the proposed theoretical model by experimental validation in modal identification experiments performed on an aluminum beam. The experimental validation was performed using a wireless intelligent sensor and actuator network (WISAN) which allows for close time synchronization between sensors (0.6-10 µs in the tested configuration) and guarantees lossless data delivery under normal conditions. The experimental results closely match theoretical predictions and show that even very small delays in output response impact the mode shapes.

  4. Mapping high-resolution incident photosynthetically active radiation over land surfaces from MODIS and GOES satellite data

    NASA Astrophysics Data System (ADS)

    Liang, S.; Wang, K.; Wang, D.; Townshend, J.; Running, S.; Tsay, S.

    2008-05-01

    Incident photosynthetically active radiation (PAR) is a key variable required by almost all terrestrial ecosystem models. Many radiation efficiency models are linearly related canopy productivity to the absorbed PAR. Unfortunately, the current incident PAR products estimated from remotely sensed data or calculated by radiation models at spatial and temporal resolutions are not sufficient for carbon cycle modeling and various applications. In this study, we aim to develop incident PAR products at one kilometer scale from multiple satellite sensors, such as Moderate Resolution Imaging Spectrometer (MODIS) and Geostationary Operational Environmental Satellite (GOES) sensor. We first developed a look-up table approach to estimate instantanerous incident PAR product from MODIS (Liang et al., 2006). The temporal observations of each pixel are used to estimate land surface reflectance and look-up tables of both aerosol and cloud are searched, based on the top-of-atmosphere reflectance and surface reflectance for determining incident PAR. The incident PAR product includes both the direct and diffuse components. The calculation of a daily integrated PAR using two different methods has also been developed (Wang, et al., 2008a). The similar algorithm has been further extended to GOES data (Wang, et al., 2008b, Zheng, et al., 2008). Extensive validation activities are conducted to evaluate the algorithms and products using the ground measurements from FLUXNET and other networks. They are also compared with other satellite products. The results indicate that our approaches can produce reasonable PAR product at 1km resolution. We have generated 1km incident PAR products over North America for several years, which are freely available to the science community. Liang, S., T. Zheng, R. Liu, H. Fang, S. C. Tsay, S. Running, (2006), Estimation of incident Photosynthetically Active Radiation from MODIS Data, Journal of Geophysical Research ¡§CAtmosphere. 111, D15208,doi:10.1029/2005JD006730. Wang, D., S. Liang, and Zheng, T., (2008a), Integrated daily PAR from MODIS. International Journal of Remote Sensing, revised. Wang, K., S. Liang, T. Zheng and D. Wang, (2008b), Simultaneous estimation of surface photosynthetically active radiation and albedo from GOES, Remote Sensing of Environment, revised. Zheng, T., S. Liang, K. Wang, (2008), Estimation of incident PAR from GOES imagery, Journal of Applied Meteorology and Climatology. in press.

  5. FINDS: A fault inferring nonlinear detection system programmers manual, version 3.0

    NASA Technical Reports Server (NTRS)

    Lancraft, R. E.

    1985-01-01

    Detailed software documentation of the digital computer program FINDS (Fault Inferring Nonlinear Detection System) Version 3.0 is provided. FINDS is a highly modular and extensible computer program designed to monitor and detect sensor failures, while at the same time providing reliable state estimates. In this version of the program the FINDS methodology is used to detect, isolate, and compensate for failures in simulated avionics sensors used by the Advanced Transport Operating Systems (ATOPS) Transport System Research Vehicle (TSRV) in a Microwave Landing System (MLS) environment. It is intended that this report serve as a programmers guide to aid in the maintenance, modification, and revision of the FINDS software.

  6. A theoretical model to predict both horizontal displacement and vertical displacement for electromagnetic induction-based deep displacement sensors.

    PubMed

    Shentu, Nanying; Zhang, Hongjian; Li, Qing; Zhou, Hongliang; Tong, Renyuan; Li, Xiong

    2012-01-01

    Deep displacement observation is one basic means of landslide dynamic study and early warning monitoring and a key part of engineering geological investigation. In our previous work, we proposed a novel electromagnetic induction-based deep displacement sensor (I-type) to predict deep horizontal displacement and a theoretical model called equation-based equivalent loop approach (EELA) to describe its sensing characters. However in many landslide and related geological engineering cases, both horizontal displacement and vertical displacement vary apparently and dynamically so both may require monitoring. In this study, a II-type deep displacement sensor is designed by revising our I-type sensor to simultaneously monitor the deep horizontal displacement and vertical displacement variations at different depths within a sliding mass. Meanwhile, a new theoretical modeling called the numerical integration-based equivalent loop approach (NIELA) has been proposed to quantitatively depict II-type sensors' mutual inductance properties with respect to predicted horizontal displacements and vertical displacements. After detailed examinations and comparative studies between measured mutual inductance voltage, NIELA-based mutual inductance and EELA-based mutual inductance, NIELA has verified to be an effective and quite accurate analytic model for characterization of II-type sensors. The NIELA model is widely applicable for II-type sensors' monitoring on all kinds of landslides and other related geohazards with satisfactory estimation accuracy and calculation efficiency.

  7. Revising the Rorschach Ego Impairment Index to Accommodate Recent Recommendations about Improving Rorschach Validity

    ERIC Educational Resources Information Center

    Viglione, Donald J.; Perry, William; Giromini, Luciano; Meyer, Gregory J.

    2011-01-01

    We used multiple regression to calculate a new Ego Impairment Index (EII-3). The aim was to incorporate changes in the component variables and distribution of the number of responses as found in the new Rorschach Performance Assessment System, while sustaining the validity and reliability of previous EIIs. The EII-3 formula was derived from a…

  8. Further validation of the gratitude, resentment, and appreciation test (GRAT).

    PubMed

    Diessner, Rhett; Lewis, Gay

    2007-08-01

    The authors conducted this study to further validate the revised short form of the Gratitude, Resentment, and Appreciation Test by investigating the relationship between GRAT-measured gratitude and two other constructs: (a) spiritual transcendence and (b) materialism. As predicted, both the GRAT and its subscales correlated positively with a measure of spiritual transcendence and negatively with a measure of materialism.

  9. Initial Evidence for the Reliability and Validity of the Student Risk Screening Scale for Internalizing and Externalizing Behaviors at the Elementary Level

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Oakes, Wendy P.; Harris, Pamela J.; Menzies, Holly Mariah; Cox, Meredith; Lambert, Warren

    2012-01-01

    We report findings of an exploratory validation study of a revised instrument: the Student Risk Screening Scale-Internalizing and Externalizing (SRSS-IE). The SRSS-IE was modified to include seven additional items reflecting characteristics of internalizing behaviors, with proposed items generated from the current literature base, review of…

  10. New Coke, Rosetta Stones, and Functional Data Analysis: Recommendations for Developing and Validating New Measures of Depression

    ERIC Educational Resources Information Center

    Santor, Darcy A.

    2006-01-01

    In this article, the author outlines six recommendations that may guide the continued development and validation of measures of depression. These are (a) articulate and revise a formal theory of signs and symptoms; (b) differentiate complex theoretical goals from pragmatic evaluation needs; (c) invest heavily in new methods and analytic models;…

  11. Professional Learning Communities Assessment: Adaptation, Internal Validity, and Multidimensional Model Testing in Turkish Context

    ERIC Educational Resources Information Center

    Dogan, Selçuk; Tatik, R. Samil; Yurtseven, Nihal

    2017-01-01

    The main purpose of this study is to adapt and validate the Professional Learning Communities Assessment Revised (PLCA-R) by Olivier, Hipp, and Huffman within the context of Turkish schools. The instrument was translated and adapted to administer to teachers in Turkey. Internal structure of the Turkish version of PLCA-R was investigated by using…

  12. Internal and External Validity of Scores on the Balanced Inventory of Desirable Responding and the Paulhus Deception Scales

    ERIC Educational Resources Information Center

    Lanyon, Richard I.; Carle, Adam C.

    2007-01-01

    The internal and external validity of scores on the two-scale Balanced Inventory of Desirable Responding (BIDR) and its recent revision, the Paulhus Deception Scales (PDS), developed to measure two facets of social desirability, were studied with three groups of forensic clients and two groups of college undergraduates (total N = 519). The two…

  13. Concurrent Validity and Classification Accuracy of the Leiter and Leiter-R in Low Functioning Children with Autism.

    ERIC Educational Resources Information Center

    Tsatsanis, Katherine D.; Dartnall, Nancy; Cicchetti, Domenic; Sparrow, Sara S.; Klin, Ami; Volkmar, Fred R.

    2003-01-01

    The concurrent validity of the original and revised versions of the Leiter International Performance Scale was examined with 26 children (ages 4-16) with autism. Although the correlation between the two tests was high (.87), there were significant intra-individual discrepancies present in 10 cases, two of which were both large and clinically…

  14. A Validation Study of the Revised Personal Safety Decision Scale

    ERIC Educational Resources Information Center

    Kim, HaeJung; Hopkins, Karen M.

    2017-01-01

    Objective: The purpose of this study is to examine the reliability and validity of an 11-item Personal Safety Decision Scale (PSDS) in a sample of child welfare workers. Methods: Data were derived from a larger cross-sectional online survey to a random stratified sample of 477 public child welfare workers in a mid-Atlantic State. An exploratory…

  15. Digital avionics systems - Principles and practices (2nd revised and enlarged edition)

    NASA Technical Reports Server (NTRS)

    Spitzer, Cary R.

    1993-01-01

    The state of the art in digital avionics systems is surveyed. The general topics addressed include: establishing avionics system requirements; avionics systems essentials in data bases, crew interfaces, and power; fault tolerance, maintainability, and reliability; architectures; packaging and fitting the system into the aircraft; hardware assessment and validation; software design, assessment, and validation; determining the costs of avionics.

  16. Screening ADHD Problems in the Sports Behavior Checklist: Factor Structure, Convergent and Divergent Validity, and Group Differences

    ERIC Educational Resources Information Center

    Clendenin, Aaron A.; Businelle, Michael S.; Kelley, Mary Lou

    2005-01-01

    The Sports Behavior Checklist (SBC) is subjected to a principal components analysis, and subscales are correlated with subscales of the Conners' Revised Parent Form and the Social Skills Rating System. Both of these analyses are conducted to determine the construct validity of the instrument. A subsample of lower socioeconomic status individuals…

  17. Assessment of the psychometric properties of the Revised Academic Hardiness Scale in college student samples.

    PubMed

    Weigold, Ingrid K; Weigold, Arne; Kim, Soyeong; Drakeford, Naomi M; Dykema, Stephanie A

    2016-10-01

    Academic hardiness, a construct representing how students tend to respond to academic stressors, has seen increased attention in the recent literature. However, as yet, no measure exists that has been validated for use with college students. The current study addresses this gap in the literature by examining the psychometric properties of the Revised Academic Hardiness Scale (RAHS; Benishek, Feldman, Shipon, Mecham, & Lopez, 2005) in several samples of college students from 2 institutions of higher education. Study 1 showed a 4-factor model (Commitment, Control of Affect, Challenge, and Control of Effort) to be the best-fitting solution. Studies 2 and 3 found support for the test-retest reliability, convergent validity, and discriminant validity of the 4 factors' scores. Finally, Study 4 showed evidence of the predictive validity of the RAHS scores, which accounted for significant variance in first- and second-semester college grade point average and persistence to a 2nd year at the university beyond the variance accounted for by high school academic variables. Overall, the RAHS appears to be a psychometrically sound measure for use with college students. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  18. Resource Conservation and Recovery Act, Part B Permit Application [for the Waste Isolation Pilot Plant (WIPP)]. Volume 5, Chapter D, Appendix D1 (conclusion), Revision 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, Neville G.W.; Heuze, Francois E.; Miller, Hamish D.S.

    1993-03-01

    The reference design for the underground facilities at the Waste Isolation Pilot Plant was developed using the best criteria available at initiation of the detailed design effort. These design criteria are contained in the US Department of Energy document titled Design Criteria, Waste Isolation Pilot Plant (WIPP). Revised Mission Concept-IIA (RMC-IIA), Rev. 4, dated February 1984. The validation process described in the Design Validation Final Report has resulted in validation of the reference design of the underground openings based on these criteria. Future changes may necessitate modification of the Design Criteria document and/or the reference design. Validation of the referencemore » design as presented in this report permits the consideration of future design or design criteria modifications necessitated by these changes or by experience gained at the WIPP. Any future modifications to the design criteria and/or the reference design will be governed by a DOE Standard Operation Procedure (SOP) covering underground design changes. This procedure will explain the process to be followed in describing, evaluating and approving the change.« less

  19. Psychometric evaluation of the Swedish adaptation of the Inventory for Assessing the Process of Cultural Competence Among Healthcare Professionals--Revised (IAPCC-R).

    PubMed

    Olt, Helen; Jirwe, Maria; Gustavsson, Petter; Emami, Azita

    2010-01-01

    The purpose of this study was to describe the translation, adaption, and psychometric evaluation process in relation to validity and reliability of the Swedish version of the instrument, Inventory for Assessing The Process of Cultural Competence Among Healthcare Professionals-Revised (IAPCC-R) following the translation, adaptation, and psychometric evaluation process. Validity tests were conducted on the response processes (N = 15), the content (N = 7), and the internal structure of the instrument (N = 334). Reliability (alpha = .65 for the total scale varying between -.01 and .65 for the different subscales) was evaluated in terms of internal consistency. Results indicated weak validity and reliability though it is difficult to conclude whether this is related to adaptation issues or the original construction.The testing of the response process identified problems in relation to respondents' conceptualization of cultural competence. The test of the content identified a weak correspondence between the items and the underlying model. In addition, a confirmatory factor analysis did not confirm the proposed structure of the instrument. This study concludes that this instrument is not valid and reliable for use with a Swedish population of practicing nurses or nursing students.

  20. FACTORIAL VALIDITY OF THE KOREAN VERSION OF THE EXERCISE DEPENDENCE SCALE-REVISED.

    PubMed

    Shin, Kyulee; You, Sukkyung

    2015-12-01

    This study evaluated the psychometric properties of the Korean version of the 21-item Exercise Dependence Scale-Revised (EDS-R). The EDS-R was designed to measure the multidimensional aspects of exercise dependence symptoms such as withdrawal, continuance, tolerance, lack of control, reductions, time, and intention. Although the EDS-R has demonstrated sound psychometric properties, it has only been validated in Western samples. Cross-cultural validations of the instrument may increase the knowledge of exercise dependence. Therefore, this study aimed to contribute to the file by investigating the validity and utility of the construct of the EDS-R, using a non-Western sample. 402 adult participants who were over 18 years of age and who reported exercising at least once a week were asked to complete the EDS-R. The results from factor analyses supported that the seven-factor model of exercise dependence symptoms showed an adequate fit for both men and women. The EDS-R scores differentiated between samples, with varying amounts of exercise; 15.4% of the sample was classified as being at risk for exercise dependence. In sum, the results indicated that the EDS-R is a psychometrically reliable assessment tool for exercise dependence symptoms in Korea.

  1. Psychometric examination and factorial validity of the Exercise Dependence Scale-Revised in Italian exercisers.

    PubMed

    Costa, Sebastiano; Cuzzocrea, Francesca; Hausenblas, Heather A; Larcan, Rosalba; Oliva, Patrizia

    2012-12-01

    Background and aims The purpose of this study was to verify the factorial structure, internal validity, reliability, and criterion validity of the 21-item Exercise Dependence Scale-Revised (EDS-R) in an Italian sample. Methods Italian voluntary (N = 519) users of gyms who had a history of regular exercise for over a year completed the EDS-R and measures of exercise frequency. Results and conclusions Confirmatory factor analyses demonstrated a good fit to the hypothesized 7-factor model, and adequate internal consistency for the scale was evidenced. Criterion validity was evidenced by significant correlations among all the subscale of the EDS and exercise frequency. Finally, individuals at risk for exercise dependence reported more exercise behavior compared to the nondependent-symptomatic and nondependent-asymptomatic groups. These results suggest that the seven subscales of the Italian version of the EDS are measuring the construct of exercise dependence as defined by the DSM-IV criteria for substance dependence and also confirm previous research using the EDS-R in other languages. More research is needed to examine the psychometric properties of the EDS-R in diverse populations with various research designs.

  2. Validation of the FFM PD count technique for screening personality pathology in later middle-aged and older adults.

    PubMed

    Van den Broeck, Joke; Rossi, Gina; De Clercq, Barbara; Dierckx, Eva; Bastiaansen, Leen

    2013-01-01

    Research on the applicability of the five factor model (FFM) to capture personality pathology coincided with the development of a FFM personality disorder (PD) count technique, which has been validated in adolescent, young, and middle-aged samples. This study extends the literature by validating this technique in an older sample. Five alternative FFM PD counts based upon the Revised NEO Personality Inventory (NEO PI-R) are computed and evaluated in terms of both convergent and divergent validity with the Assessment of DSM-IV Personality Disorders Questionnaire (shortly ADP-IV; DSM-IV, Diagnostic and Statistical Manual of Mental Disorders - Fourth edition). For the best working count for each PD normative data are presented, from which cut-off scores are derived. The validity of these cut-offs and their usefulness as a screening tool is tested against both a categorical (i.e., the DSM-IV - Text Revision), and a dimensional (i.e., the Dimensional Assessment of Personality Pathology; DAPP) measure of personality pathology. All but the Antisocial and Obsessive-Compulsive counts exhibited adequate convergent and divergent validity, supporting the use of this method in older adults. Using the ADP-IV and the DAPP - Short Form as validation criteria, results corroborate the use of the FFM PD count technique to screen for PDs in older adults, in particular for the Paranoid, Borderline, Histrionic, Avoidant, and Dependent PDs. Given the age-neutrality of the NEO PI-R and the considerable lack of valid personality assessment tools, current findings appear to be promising for the assessment of pathology in older adults.

  3. The psychometric validation of the Social Problem-Solving Inventory--Revised with UK incarcerated sexual offenders.

    PubMed

    Wakeling, Helen C

    2007-09-01

    This study examined the reliability and validity of the Social Problem-Solving Inventory--Revised (SPSI-R; D'Zurilla, Nezu, & Maydeu-Olivares, 2002) with a population of incarcerated sexual offenders. An availability sample of 499 adult male sexual offenders was used. The SPSI-R had good reliability measured by internal consistency and test-retest reliability, and adequate validity. Construct validity was determined via factor analysis. An exploratory factor analysis extracted a two-factor model. This model was then tested against the theory-driven five-factor model using confirmatory factor analysis. The five-factor model was selected as the better fitting of the two, and confirmed the model according to social problem-solving theory (D'Zurilla & Nezu, 1982). The SPSI-R had good convergent validity; significant correlations were found between SPSI-R subscales and measures of self-esteem, impulsivity, and locus of control. SPSI-R subscales were however found to significantly correlate with a measure of socially desirable responding. This finding is discussed in relation to recent research suggesting that impression management may not invalidate self-report measures (e.g. Mills & Kroner, 2005). The SPSI-R was sensitive to sexual offender intervention, with problem-solving improving pre to post-treatment in both rapists and child molesters. The study concludes that the SPSI-R is a reasonably internally valid and appropriate tool to assess problem-solving in sexual offenders. However future research should cross-validate the SPSI-R with other behavioural outcomes to examine the external validity of the measure. Furthermore, future research should utilise a control group to determine treatment impact.

  4. Validation of a home food inventory among low-income Spanish- and Somali-speaking families.

    PubMed

    Hearst, Mary O; Fulkerson, Jayne A; Parke, Michelle; Martin, Lauren

    2013-07-01

    To refine and validate an existing home food inventory (HFI) for low-income Somali- and Spanish-speaking families. Formative assessment was conducted using two focus groups, followed by revisions of the HFI, translation of written materials and instrument validation in participants’ homes. Twin Cities Metropolitan Area, Minnesota, USA. Thirty low-income families with children of pre-school age (fifteen Spanish-speaking; fifteen Somali-speaking) completed the HFI simultaneously with, but independently of, a trained staff member. Analysis consisted of calculation of both item-specific and average food group kappa coefficients, specificity, sensitivity and Spearman’s correlation between participants’ and staff scores as a means of assessing criterion validity of individual items, food categories and the obesogenic score. The formative assessment revealed the need for few changes/additions for food items typically found in Spanish-speaking households. Somali-speaking participants requested few additions, but many deletions, including frozen processed food items, non-perishable produce and many sweets as they were not typical food items kept in the home. Generally, all validity indices were within an acceptable range, with the exception of values associated with items such as ‘whole wheat bread’ (k = 0.16). The obesogenic score (presence of high-fat, high-energy foods) had high criterion validity with k = 0.57, sensitivity = 91.8%, specificity = 70.6% and Spearman correlation = 0.78. The revised HFI is a valid assessment tool for use among Spanish and Somali households. This instrument refinement and validation process can be replicated with other population groups.

  5. Sensor validation and fusion for gas turbine vibration monitoring

    NASA Astrophysics Data System (ADS)

    Yan, Weizhong; Goebel, Kai F.

    2003-08-01

    Vibration monitoring is an important practice throughout regular operation of gas turbine power systems and, even more so, during characterization tests. Vibration monitoring relies on accurate and reliable sensor readings. To obtain accurate readings, sensors are placed such that the signal is maximized. In the case of characterization tests, strain gauges are placed at the location of vibration modes on blades inside the gas turbine. Due to the prevailing harsh environment, these sensors have a limited life and decaying accuracy, both of which impair vibration assessment. At the same time bandwidth limitations may restrict data transmission, which in turn limits the number of sensors that can be used for assessment. Knowing the sensor status (normal or faulty), and more importantly, knowing the true vibration level of the system all the time is essential for successful gas turbine vibration monitoring. This paper investigates a dynamic sensor validation and system health reasoning scheme that addresses the issues outlined above by considering only the information required to reliably assess system health status. In particular, if abnormal system health is suspected or if the primary sensor is determined to be faulted, information from available "sibling" sensors is dynamically integrated. A confidence expresses the complex interactions of sensor health and system health, their reliabilities, conflicting information, and what the health assessment is. Effectiveness of the scheme in achieving accurate and reliable vibration evaluation is then demonstrated using a combination of simulated data and a small sample of a real-world application data where the vibration of compressor blades during a real time characterization test of a new gas turbine power system is monitored.

  6. Real-time In-Flight Strain and Deflection Monitoring with Fiber Optic Sensors

    NASA Technical Reports Server (NTRS)

    Richards, Lance; Parker, Allen R.; Ko, William L.; Piazza, Anthony

    2008-01-01

    This viewgraph presentation reviews Dryden's efforts to develop in-flight monitoring based on Fiber Optics. One of the motivating factors for this development was the breakup of the Helios aircraft. On Ikhana the use of fiber optics for wing shape sensing is being developed. They are being used to flight validate fiber optic sensor measurements and real-time wing shape sensing predictions on NASA's Ikhana vehicle; validate fiber optic mathematical models and design tools; Assess technical viability and, if applicable, develop methodology and approach to incorporate wing shape measurements within the vehicle flight control system, and develop and flight validate advanced approaches to perform active wing shape control.

  7. Construct and content validity of the Turkish Birth Satisfaction Scale - Revised (T-BSS-R).

    PubMed

    Göncü Serhatlıoğlu, Seda; Karahan, Nazan; Hollins Martin, Caroline J; Martin, Colin R

    2018-07-01

    The Birth Satisfaction Scale - Revised (BSS-R) is a valid and reliable scale designed to assess women's experiences of labour and childbirth. To assess factor structure, validity, and reliability of the Turkish Birth Satisfaction Scale - Revised (T-BSS-R) using data collected from a Turkish population. Istanbul Ministry of Health Zeynep Kamil Women's and Children's Training and Research Hospital. A convenience sample of healthy child-bearing women (n = 120) who had experienced a spontaneous vertex delivery at full term. A survey was conducted post backtranslating the T-BSS-R, with survey data analysed using confirmatory factor analysis. Factor modelling found three subscales embedded in the T-BSS-R, which indicated a good model fit, χ 2 = 44.67, CFI = .94; RMSEA = .057; SRMR = .075. A Chi-square value of 1.33 also indicated a good fit. Means for the T-BSS-R subdimensions (1) Stress Experienced (T-BSS-SE-R) = 6.86 ± 3.10, (2) Women's Attributes (T-BSS-WA-R) = 2.84 ± 1.89, (3) Quality of Care (T-BSS-QC-R) = 10.69 ± 3.19 and total scale = 20.39 ± 5.98. The Cronbach alpha coefficient for total scale = 0.71 and for subdimensions T-BSS-SE-R = 0.55, T-BSS-WA-R = 0.44 and T-BSS-QC-R = -0.74. Data analysis determined that the T-BSS-R is a valid and reliable instrument to measure birth satisfaction in a population of Turkish women. The T-BSS-R is available for use from c.hollinsmartin@napier.ac.uk .

  8. The development and validation of the Physical Appearance Comparison Scale-3 (PACS-3).

    PubMed

    Schaefer, Lauren M; Thompson, J Kevin

    2018-05-21

    Appearance comparison processes are implicated in the development of body-image disturbance and disordered eating. The Physical Appearance Comparison Scale-Revised (PACS-R) assesses the simple frequency of appearance comparisons; however, research has suggested that other aspects of appearance comparisons (e.g., comparison direction) may moderate the association between comparisons and their negative outcomes. In the current study, the PACS-R was revised to examine aspects of comparisons with relevance to body-image and eating outcomes. Specifically, the measure was modified to examine (a) dimensions of physical appearance relevant to men and women (i.e., weight-shape, muscularity, and overall physical appearance), (b) comparisons with proximal and distal targets, (c) upward versus downward comparisons, and (d) the acute emotional impact of comparisons. The newly revised measure, labeled the PACS-3, along with existing measures of appearance comparison, body satisfaction, eating pathology, and self-esteem, was completed by 1,533 college men and women. Exploratory and confirmatory factor analyses were conducted to examine the factor structure of the PACS-3. In addition, the reliability, convergent validity, and incremental validity of the PACS-3 scores were examined. The final PACS-3 comprises 27 items and 9 subscales: Proximal: Frequency, Distal: Frequency, Muscular: Frequency, Proximal: Direction, Distal: Direction, Muscular: Direction, Proximal: Effect, Distal: Effect, and Muscular: Effect. the PACS-3 subscale scores demonstrated good reliability and convergent validity. Moreover, the PACS-3 subscales greatly improved the prediction of body satisfaction and disordered eating relative to existing measures of appearance comparison. Overall, the PACS-3 improves upon existing scales and offers a comprehensive assessment of appearance-comparison processes. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  9. How often is the office visit needed? Predicting total knee arthroplasty revision risk using pain/function scores.

    PubMed

    Hightower, Charles D; Hightower, Lisa S; Tatman, Penny J; Morgan, Patrick M; Gioe, Terence; Singh, Jasvinder A

    2016-08-24

    Most patients have favorable outcomes after primary total knee arthroplasty (TKA). Well-validated methods to predict the risk of poor outcomes have not been developed or implemented. Several patients have annual clinic visits despite well-funcitoning TKA, as a routine practice, to detect early failure requiring revision surgery. It is not known whether assessment of pain and function can be used as a predictive tool for early failure and revision to guide practice. Our objective was to determine whether pain and function can predict revision after TKA. We retrospectively studied data from a large prospectively gathered TKA registry to examine changes in outcome scores for primary TKAs undergoing revision compared to those not requiring revision to determine the factors that are predictive for revision. Of the 1,012 patients, 721 had had a single-sided primary TKA and had American Knee Society (AKS) Scores for three or more visits. 46 patients underwent revision, 23 acutely (fracture, traumatic component failure or acute infection) and 23 for latent causes (late implant loosening, progressive osteolysis, or pain and indolent infection). Mean age was 70 years for the non-revision patients, and 64 years for those revised. Both AKS Clinical and AKS Function Scores for non-revised patients were higher than in revision patients, higher in acute revision compared to latent revision patients. Significant predictors of revision surgery were preoperative, 3- and 15-month postoperative AKS Clinical Scores and 3-month AKS Function Scores. At 15-month post-TKA, a patient with a low calculated probability of revision, 32 % or less, was unlikely to require revision surgery with a negative predictive value of 99 %. Time dependent interval evaluation post-TKA with the AKS outcome scores may provide the ability to assign risk of revision to patients at the 15-month follow-up visit. If these findings can be replicated using a patient-reported measure, a virtual follow-up with patient-reported outcomes and X-ray review may be an alternative to clinic visit for patients doing well.

  10. Multifuctional integrated sensors (MFISES).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Homeijer, Brian D.; Roozeboom, Clifton

    2015-10-01

    Many emerging IoT applications require sensing of multiple physical and environmental parameters for: completeness of information, measurement validation, unexpected demands, improved performance. For example, a typical outdoor weather station measures temperature, humidity, barometric pressure, light intensity, rainfall, wind speed and direction. Existing sensor technologies do not directly address the demand for cost, size, and power reduction in multi-paramater sensing applications. Industry sensor manufacturers have developed integrated sensor systems for inertial measurements that combine accelerometers, gyroscopes, and magnetometers, but do not address environmental sensing functionality. In existing research literature, a technology gap exists between the functionality of MEMS sensors and themore » real world applications of the sensors systems.« less

  11. Permanents Stations for Calibration/Validation of Thermal Sensors over Spain: Ready for the Advent of Sentinel-3

    NASA Astrophysics Data System (ADS)

    Sobrino, J. A.; Skokovic, D.; Jimenez-Munoz, J. C.; Soria, G.; Julien, Y.

    2016-08-01

    The Global Change Unit (GCU) at the University of Valencia has been involved in several calibration/validation (cal/val) activities carried out in dedicated field campaigns organized by ESA and other organisms. However, permanent stations are required in order to ensure a long-term and continuous calibration of on-orbit sensors. In the framework of the CEOS-Spain project, the GCU has managed the setting-up and launch of experimental sites in Spain for the calibration of thermal infrared sensors and the validation of Land Surface Temperature (LST) products derived from those data. Currently, three sites have been identified and equipped: the agricultural area of Barrax (39.05N, 2.1W), the marshland area in the National Park of Doñana (36.99N, 6.44W), and the semi-arid area of the National Park of Cabo de Gata (36.83N, 2.25W). The activities of the CEOS-Spain project also included the implementation of an operational processing chain in order to provide in near-real time different remote sensing products, including LST. This work presents the performance of the permanent stations installed over the different test areas, as well as the cal/val results obtained for a number of Earth Observation sensors: SEVIRI, MODIS and Landsat series. We also show the results obtained in the validation of LST products derived from AATSR, with discussion on the implications for the forthcoming Sentinel-3/SLSTR.

  12. Perceptions and Uses of "GRE"® Scores after the Launch of the "GRE"® Revised General Test in August 2011. ETS GRE® Board Research Report. ETS GRE®-17-01. ETS Research Report. RR-17-03

    ERIC Educational Resources Information Center

    Klieger, David M.; Belur, Vinetha; Kotloff, Lauren J.

    2017-01-01

    This survey study investigated how graduate school admissions committees perceive and use the "GRE"® General Test and "GRE"® Subject Tests after the launch of the "GRE"® revised General Test in August 2011. These perceptions and uses impact the validity of the tests. Prior research about the perceptions and uses of…

  13. IN SITU ESTIMATES OF FOREST LAI FOR MODIS DATA VALIDATION

    EPA Science Inventory

    Satellite remote sensor data are commonly used to assess ecosystem conditions through synoptic monitoring of terrestrial vegetation extent, biomass, and seasonal dynamics. Two commonly used vegetation indices that can be derived from various remote sensor systems include the Norm...

  14. Bayesian truthing as experimental verification of C4ISR sensors

    NASA Astrophysics Data System (ADS)

    Jannson, Tomasz; Forrester, Thomas; Romanov, Volodymyr; Wang, Wenjian; Nielsen, Thomas; Kostrzewski, Andrew

    2015-05-01

    In this paper, the general methodology for experimental verification/validation of C4ISR and other sensors' performance, is presented, based on Bayesian inference, in general, and binary sensors, in particular. This methodology, called Bayesian Truthing, defines Performance Metrics for binary sensors in: physics, optics, electronics, medicine, law enforcement, C3ISR, QC, ATR (Automatic Target Recognition), terrorism related events, and many others. For Bayesian Truthing, the sensing medium itself is not what is truly important; it is how the decision process is affected.

  15. On-Orbit Calibration of a Multi-Spectral Satellite Satellite Sensor Using a High Altitude Airborne Imaging Spectrometer

    NASA Technical Reports Server (NTRS)

    Green, R. O.; Shimada, M.

    1996-01-01

    Earth-looking satellites must be calibrated in order to quantitatively measure and monitor components of land, water and atmosphere of the Earth system. The inevitable change in performance due to the stress of satellite launch requires that the calibration of a satellite sensor be established and validated on-orbit. A new approach to on-orbit satellite sensor calibration has been developed using the flight of a high altitude calibrated airborne imaging spectrometer below a multi-spectral satellite sensor.

  16. The predictive validity of three versions of the MCAT in relation to performance in medical school, residency, and licensing examinations: a longitudinal study of 36 classes of Jefferson Medical College.

    PubMed

    Callahan, Clara A; Hojat, Mohammadreza; Veloski, Jon; Erdmann, James B; Gonnella, Joseph S

    2010-06-01

    The Medical College Admission Test (MCAT) has undergone several revisions for content and validity since its inception. With another comprehensive review pending, this study examines changes in the predictive validity of the MCAT's three recent versions. Study participants were 7,859 matriculants in 36 classes entering Jefferson Medical College between 1970 and 2005; 1,728 took the pre-1978 version of the MCAT; 3,032 took the 1978-1991 version, and 3,099 took the post-1991 version. MCAT subtest scores were the predictors, and performance in medical school, attrition, scores on the medical licensing examinations, and ratings of clinical competence in the first year of residency were the criterion measures. No significant improvement in validity coefficients was observed for performance in medical school or residency. Validity coefficients for all three versions of the MCAT in predicting Part I/Step 1 remained stable (in the mid-0.40s, P < .01). A systematic decline was observed in the validity coefficients of the MCAT versions in predicting Part II/Step 2. It started at 0.47 for the pre-1978 version, decreased to between 0.42 and 0.40 for the 1978-1991 versions, and to 0.37 for the post-1991 version. Validity coefficients for the MCAT versions in predicting Part III/Step 3 remained near 0.30. These were generally larger for women than men. Although the findings support the short- and long-term predictive validity of the MCAT, opportunities to strengthen it remain. Subsequent revisions should increase the test's ability to predict performance on United States Medical Licensing Examination Step 2 and must minimize the differential validity for gender.

  17. Comprehensive Calibration and Validation Site for Information Remote Sensing

    NASA Astrophysics Data System (ADS)

    Li, C. R.; Tang, L. L.; Ma, L. L.; Zhou, Y. S.; Gao, C. X.; Wang, N.; Li, X. H.; Wang, X. H.; Zhu, X. H.

    2015-04-01

    As a naturally part of information technology, Remote Sensing (RS) is strongly required to provide very precise and accurate information product to serve industry, academy and the public at this information economic era. To meet the needs of high quality RS product, building a fully functional and advanced calibration system, including measuring instruments, measuring approaches and target site become extremely important. Supported by MOST of China via national plan, great progress has been made to construct a comprehensive calibration and validation (Cal&Val) site, which integrates most functions of RS sensor aviation testing, EO satellite on-orbit caration and performance assessment and RS product validation at this site located in Baotou, 600km west of Beijing. The site is equipped with various artificial standard targets, including portable and permanent targets, which supports for long-term calibration and validation. A number of fine-designed ground measuring instruments and airborne standard sensors are developed for realizing high-accuracy stepwise validation, an approach in avoiding or reducing uncertainties caused from nonsynchronized measurement. As part of contribution to worldwide Cal&Val study coordinated by CEOS-WGCV, Baotou site is offering its support to Radiometric Calibration Network of Automated Instruments (RadCalNet), with an aim of providing demonstrated global standard automated radiometric calibration service in cooperation with ESA, NASA, CNES and NPL. Furthermore, several Cal&Val campaigns have been performed during the past years to calibrate and validate the spaceborne/airborne optical and SAR sensors, and the results of some typical demonstration are discussed in this study.

  18. Validation Test Report for the Automated Optical Processing System (AOPS) Version 4.12

    DTIC Science & Technology

    2015-09-03

    NPP) with the VIIRS sensor package as well as data from the Geostationary Ocean Color Imager (GOCI) sensor, aboard the Communication Ocean and...capability • Prepare the NRT Geostationary Ocean Color Imager (GOCI) data stream for integration into operations. • Improvements in sensor...Navy (DON) Environmental Data Records (EDRs) Expeditionary Warfare (EXW) Geostationary Ocean Color Imager (GOCI) Gulf of Mexico (GOM) Hierarchical

  19. Colour cyclic code for Brillouin distributed sensors

    NASA Astrophysics Data System (ADS)

    Le Floch, Sébastien; Sauser, Florian; Llera, Miguel; Rochat, Etienne

    2015-09-01

    For the first time, a colour cyclic coding (CCC) is theoretically and experimentally demonstrated for Brillouin optical time-domain analysis (BOTDA) distributed sensors. Compared to traditional intensity-modulated cyclic codes, the code presents an additional gain of √2 while keeping the same number of sequences as for a colour coding. A comparison with a standard BOTDA sensor is realized and validates the theoretical coding gain.

  20. Development of an In-Situ Decommissioning Sensor Network Test Bed for Structural Condition Monitoring - 12156

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeigler, Kristine E.; Ferguson, Blythe A.

    2012-07-01

    The Savannah River National Laboratory (SRNL) has established an In Situ Decommissioning (ISD) Sensor Network Test Bed, a unique, small scale, configurable environment, for the assessment of prospective sensors on actual ISD system material, at minimal cost. The Department of Energy (DOE) is presently implementing permanent entombment of contaminated, large nuclear structures via ISD. The ISD end state consists of a grout-filled concrete civil structure within the concrete frame of the original building. Validation of ISD system performance models and verification of actual system conditions can be achieved through the development a system of sensors to monitor the materials andmore » condition of the structure. The ISD Sensor Network Test Bed has been designed and deployed to addresses the DOE-Environmental Management Technology Need to develop a remote monitoring system to determine and verify ISD system performance. Commercial off-the-shelf sensors have been installed on concrete blocks taken from walls of the P Reactor Building at the Savannah River Site. Deployment of this low-cost structural monitoring system provides hands-on experience with sensor networks. The initial sensor system consists of groutable thermistors for temperature and moisture monitoring, strain gauges for crack growth monitoring, tilt-meters for settlement monitoring, and a communication system for data collection. Baseline data and lessons learned from system design and installation and initial field testing will be utilized for future ISD sensor network development and deployment. The Sensor Network Test Bed at SRNL uses COTS sensors on concrete blocks from the outer wall of the P Reactor Building to measure conditions expected to occur in ISD structures. Knowledge and lessons learned gained from installation, testing, and monitoring of the equipment will be applied to sensor installation in a meso-scale test bed at FIU and in future ISD structures. The initial data collected from the sensors installed on the P Reactor Building blocks define the baseline materials condition of the P Reactor ISD external concrete structure. Continued monitoring of the blocks will enable evaluation of the effects of aging on the P Reactor ISD structure. The collected data will support validation of the material degradation model and assessment of the condition of the ISD structure over time. The following are recommendations for continued development of the ISD Sensor Network Test Bed: - Establish a long-term monitoring program using the concrete blocks with existing sensor and/or additional sensors for trending the concrete materials and structural condition; - Continue development of a stand-alone test bed sensor system that is self-powered and provides wireless transmission of data to a user-accessible dashboard; - Develop and implement periodic NDE/DE characterization of the concrete blocks to provide verification and validation for the measurements obtained through the sensor system and concrete degradation model(s). (authors)« less

  1. Automatically augmenting lifelog events using pervasively generated content from millions of people.

    PubMed

    Doherty, Aiden R; Smeaton, Alan F

    2010-01-01

    In sensor research we take advantage of additional contextual sensor information to disambiguate potentially erroneous sensor readings or to make better informed decisions on a single sensor's output. This use of additional information reinforces, validates, semantically enriches, and augments sensed data. Lifelog data is challenging to augment, as it tracks one's life with many images including the places they go, making it non-trivial to find associated sources of information. We investigate realising the goal of pervasive user-generated content based on sensors, by augmenting passive visual lifelogs with "Web 2.0" content collected by millions of other individuals.

  2. STS-114 Engine Cut-off Sensor Anomaly Technical Consultation Report

    NASA Technical Reports Server (NTRS)

    Wilson, Timmy R.; Kichak, Robert A.; Ungar, Eugene K.; Cherney, Robert; Rickman, Steve L.

    2009-01-01

    The NESC consultation team participated in real-time troubleshooting of the Main Propulsion System (MPS) Engine Cutoff (ECO) sensor system failures during STS-114 launch countdown. The team assisted with External Tank (ET) thermal and ECO Point Sensor Box (PSB) circuit analyses, and made real-time inputs to the Space Shuttle Program (SSP) problem resolution teams. Several long-term recommendations resulted. One recommendation was to conduct cryogenic tests of the ECO sensors to validate, or disprove, the theory that variations in circuit impedance due to cryogenic effects on swaged connections within the sensor were the root cause of STS-114 failures.

  3. Standardization of the Hare Psychopathy Checklist-Revised in a Spanish prison sample.

    PubMed

    Moltó, J; Poy, R; Torrubia, R

    2000-01-01

    This investigation examined the reliability, validity, and factor structure of the Hare Psychopathy Checklist-Revised (PCL-R) in male adult Spanish prison populations (n = 117). The interrater reliability and internal consistency coefficients were high, and similar to those obtained in other countries. This data provides support for the homogeneity and unidimensionality of the psychopathy construct in Spanish male prison samples. The analysis of factor structure also replicated the two factor solution of previous studies. The two factors showed different patterns of intercorrelations with several self-report measures of personality, demographic, and criminal history variables, which confirmed the construct validity of PCL-R. The results confirm the psychometric properties of the PCL-R as a measure of psychopathy in Spanish male inmates, and suggest that psychopathy is a construct also observed in Southern European countries.

  4. Computer-assisted Biology Learning Materials: Designing and Developing an Interactive CD on Spermatogenesis

    NASA Astrophysics Data System (ADS)

    Haviz, M.

    2018-04-01

    The purpose of this article is to design and develop an interactive CD on spermatogenesis. This is a research and development. Procedure of development is making an outline of media program, making flowchart, making story board, gathering of materials, programming and finishing. The quantitative data obtained were analyzed by descriptive statistics. Qualitative data obtained were analyzed with Miles and Huberman techniques. The instrument used is a validation sheet. The result of CD design with a Macro flash MX program shows there are 17 slides generated. This prototype obtained a valid value after a self-review technique with many revisions, especially on sound and programming. This finding suggests that process-oriented spermatogenesis can be audio-visualized into a more comprehensive form of learning media. But this interactive CD product needs further testing to determine consistency and resistance to revisions.

  5. Construct Validation of the Self-Efficacy Teaching and Knowledge Instrument for Science Teachers-Revised (SETAKIST-R): Lessons Learned

    NASA Astrophysics Data System (ADS)

    Pruski, Linda A.; Blanco, Sharon L.; Riggs, Rosemary A.; Grimes, Kandi K.; Fordtran, Chase W.; Barbola, Gina M.; Cornell, John E.; Lichtenstein, Michael J.

    2013-11-01

    Described herein is the academic lineage and independent validation of the Self-Efficacy Teaching and Knowledge Instrument for Science Teachers-Revised (SETAKIST-R). Data from 334 K-12 science teachers were analyzed using Partial Credit Rasch models. Principal components analysis on the person-item residuals suggest two latent dimensions: Knowledge and Teaching Self-Efficacies. Item-fit statistics were used to select items for each subscale. Person and item separation (reliability) indices were quite low, and we noted disordered response patterns on the person-item maps that revealed problems with item content and/or scaling for both subscales. These issues include the presence of: verbal negatives, ambiguous modifiers, counter-intuitive scaling, and an "undecided/uncertain" option. The SETAKIST-R, in its current form, cannot be recommended as a measure of science teacher self-efficacy.

  6. Cross-cultural adaptation and validation of als Functional Rating Scale-Revised in Portuguese language.

    PubMed

    Guedes, Keyte; Pereira, Cecília; Pavan, Karina; Valério, Berenice Cataldo Oliveira

    2010-02-01

    The aim of this study is the cross-cultural, as well as to validate in Portuguese language the Amyotrophic Lateral Sclerosis Functional Rating Scale - Revised (ALSFRS-R). We performed a prospective study of individuals with amyotrophic lateral sclerosis (ALS) clinically defined. The scale, after obtaining the final version in Portuguese, was administered in 22 individuals and three weeks after re-applied. There were no significant differences between the application and reapplication of the scale (p=0.069). The linear regression and internal consistency measured by Pearson correlation and alpha Conbrach were significant with r=0.975 e alpha=0.934. The reliability test-retest demonstrated by intraclass correlation coefficient was strong with ICC=0.975. Therefore, this version proved to be applicable, reliable and easy to be conducted in clinical practice and research.

  7. Psychometric properties of a revised version of the Assisting Hand Assessment (Kids-AHA 5.0).

    PubMed

    Holmefur, Marie M; Krumlinde-Sundholm, Lena

    2016-06-01

    The aim of this study was to scrutinize the Assisting Hand Assessment (AHA) version 4.4 for possible improvements and to evaluate the psychometric properties regarding internal scale validity and aspects of reliability of a revised version of the AHA. In collaboration with experts, scoring criteria were changed for four items, and one fully new item was constructed. Twenty-two original, one new, and four revised items were scored for 164 assessments of children with unilateral cerebral palsy aged 18 months to 12 years. Rasch measurement analysis was used to evaluate internal scale validity by exploring rating-scale functioning, item and person goodness-of-fit, and principal component analysis. Targeting and scale reliability were also evaluated. After removal of misfitting items, a 20-item scale showed satisfactory goodness-of-fit. Unidimensionality was confirmed by principal component analysis. The rating scale functioned well for the 20 items, and the item difficulty was well suited to the ability level of the sample. The person reliability coefficient was 0.98, indicating high separation ability of the scale. A conversion table of AHA scores between the previous version (4.4) and the new version (5.0) was constructed. The new, 20-item version of the Kids-AHA (version 5.0), demonstrated excellent internal scale validity, suggesting improved responsiveness to changes and shortened scoring time. For comparison of scores from version 4.4 to 5.0, a transformation table is presented. © 2015 Mac Keith Press.

  8. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  9. Validation of the iHealth BP3 upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Chen, Can; Shang, Fujun; Wang, Jiepin; Chen, Jianghong; Ji, Na; Wan, Yi

    2012-12-01

    This study aimed to evaluate the performance of the iHealth BP3 upper-arm blood pressure monitor, which is designed for clinic use and self-measurement of blood pressure using Apple touch devices as an interface. The European Society of Hypertension International Protocol (ESH-IP) revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. Ninty-nine couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The 33 participants, age 47.1±12.3 years (age range 27-69 years) and arm circumference 30.0±4.4 cm, had a mean systolic blood pressure (SBP) of 143.9±27.4 mmHg and a mean diastolic blood pressure (DBP) of 90.1±18.3 mmHg. The device passed all of the requirements fulfilling the standards of the protocol, and the mean±SD device-observer difference was 2.8±4.2 mmHg for SBP and -0.4±3.5 mmHg for DBP. According to the results of the validation study on the basis of the ESH-IP revision 2010, the iHealth BP3 can be recommended for clinic use and self-measurement in an adult population. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

  10. Aerosol Climate Time Series in ESA Aerosol_cci

    NASA Astrophysics Data System (ADS)

    Popp, Thomas; de Leeuw, Gerrit; Pinnock, Simon

    2016-04-01

    Within the ESA Climate Change Initiative (CCI) Aerosol_cci (2010 - 2017) conducts intensive work to improve algorithms for the retrieval of aerosol information from European sensors. Meanwhile, full mission time series of 2 GCOS-required aerosol parameters are completely validated and released: Aerosol Optical Depth (AOD) from dual view ATSR-2 / AATSR radiometers (3 algorithms, 1995 - 2012), and stratospheric extinction profiles from star occultation GOMOS spectrometer (2002 - 2012). Additionally, a 35-year multi-sensor time series of the qualitative Absorbing Aerosol Index (AAI) together with sensitivity information and an AAI model simulator is available. Complementary aerosol properties requested by GCOS are in a "round robin" phase, where various algorithms are inter-compared: fine mode AOD, mineral dust AOD (from the thermal IASI spectrometer, but also from ATSR instruments and the POLDER sensor), absorption information and aerosol layer height. As a quasi-reference for validation in few selected regions with sparse ground-based observations the multi-pixel GRASP algorithm for the POLDER instrument is used. Validation of first dataset versions (vs. AERONET, MAN) and inter-comparison to other satellite datasets (MODIS, MISR, SeaWIFS) proved the high quality of the available datasets comparable to other satellite retrievals and revealed needs for algorithm improvement (for example for higher AOD values) which were taken into account for a reprocessing. The datasets contain pixel level uncertainty estimates which were also validated and improved in the reprocessing. For the three ATSR algorithms the use of an ensemble method was tested. The paper will summarize and discuss the status of dataset reprocessing and validation. The focus will be on the ATSR, GOMOS and IASI datasets. Pixel level uncertainties validation will be summarized and discussed including unknown components and their potential usefulness and limitations. Opportunities for time series extension with successor instruments of the Sentinel family will be described and the complementarity of the different satellite aerosol products (e.g. dust vs. total AOD, ensembles from different algorithms for the same sensor) will be discussed.

  11. A pilot study on diagnostic sensor networks for structure health monitoring.

    DOT National Transportation Integrated Search

    2013-08-01

    The proposal was submitted in an effort to obtain some preliminary results on using sensor networks for real-time structure health : monitoring. The proposed work has twofold: to develop and validate an elective algorithm for the diagnosis of coupled...

  12. Taxonomic revision of Rochefortia Sw. (Ehretiaceae, Boraginales)

    PubMed Central

    Irimia, Ramona-Elena

    2016-01-01

    Abstract Background Rochefortia is a small taxon of woody plants in the Ehretiaceae (Boraginales) exhibiting coriaceous leaves with cystoliths, small whitish flowers and drupaceous fruits containing four pyrenes. It shares the dioecious sex distribution with its sister group Lepidocordia and can be delimited from the latter (and all other Ehretiaceae) by the presence of thorns. Neotropical Rochefortia is distributed over most Caribbean islands, Central America and northern South America. Twenty-eight validly published names (corresponding to twenty-one typified taxa at the species level and below) are available in Rochefortia, but the precise number of species to be accepted has been elusive before this revision. New information In the course of the present revision, 353 herbarium collections, comprising approximately 540 Rochefortia specimens, were entried into a BRAHMS data base providing information about protologues and types and retrospective georeferences if possible. Based on the combination of molecular and morphological data we propose to recognise nine species of Rochefortia, namely R. acanthophora, R. bahamensis, R. barloventensis, R. cubensis, R. cuneata, R. lundellii, R. oblongata, R. spinosa and R. stellata (the remaining nineteen validly published names are synonymised under such names). Morphological description of each species and an identification key are provided. PMID:27346952

  13. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  14. The Hispanic Stress Inventory Version 2: Improving the Assessment of Acculturation Stress

    PubMed Central

    Cervantes, Richard C.; Fisher, Dennis G.; Padilla, Amado M.; Napper, Lucy E.

    2015-01-01

    This paper reports on a two-phase study to revise the Hispanic Stress Inventory (HSI) (Cervantes, Padilla, & Salgado de Snyder, 1991). The necessity for a revised stress-assessment instrument was determined by demographic and political shifts affecting Latin American immigrants and later-generation Hispanics in the U.S. in the two decades since the development of the HSI. The data for the revision of the HSI (termed the HSI2) was collected in four sites: Los Angeles, El Paso, Miami, and Boston and included 941 immigrants and 575 US-born Hispanics and a diverse population of Hispanic subgroups. The immigrant version of the HSI2 includes 10 stress subscales, while the US-born version includes 6 stress subscales. Both versions of the HSI2 are shown to possess satisfactory Cronbach alpha reliabilities and demonstrate expert-based content validity, as well as concurrent validity when correlated with subscales of the Brief Symptom Inventory and the Patient Health Questionnaire. The new HSI2 instruments are recommended for use by clinicians and researchers interested in assessing psychosocial stress among diverse Hispanic populations of various ethnic subgroups, age groups, and geographic location. PMID:26348029

  15. Initial Evidence for the Reliability and Validity of the Student Risk Screening Scale for Internalizing and Externalizing Behaviors at the Middle School Level

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Oakes, Wendy Peia; Carter, Erik W.; Lambert, Warren E.; Jenkins, Abbie B.

    2013-01-01

    We reported findings of an exploratory validation study of a revised universal screening instrument: the Student Risk Screening Scale--Internalizing and Externalizing (SRSS-IE) for use with middle school students. Tested initially for use with elementary-age students, the SRSS-IE was adapted to include seven additional items reflecting…

  16. A Validation of the Student Risk Screening Scale for Internalizing and Externalizing Behaviors: Patterns in Rural and Urban Elementary Schools

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Menzies, Holly M.; Oakes, Wendy P.; Lambert, Warren; Cox, Meredith; Hankins, Katy

    2012-01-01

    We report findings of two studies, one conducted in a rural school district (N = 982) and a second conducted in an urban district (N = 1,079), offering additional evidence of the reliability and validity of a revised instrument, the Student Risk Screening Scale-Internalizing and Externalizing (SRSS-IE), to accurately detect internalizing and…

  17. Diagnosing Autism in Adults with Intellectual Disability: Validation of the DiBAS-R in an Independent Sample

    ERIC Educational Resources Information Center

    Heinrich, Manuel; Böhm, Julia; Sappok, Tanja

    2018-01-01

    The study assessed the diagnostic validity of the diagnostic behavioral assessment for autism spectrum disorders-revised (DiBAS-R; 19-item screening scale based on ratings by caregivers) in a clinical sample of 381 adults with ID. Analysis revealed a sensitivity of 0.82 and a specificity of 0.67 in the overall sample (70.3% agreement). Sensitivity…

  18. Validity of the Children's Social Behavior Questionnaire (CSBQ) in Children with Intellectual Disability: Comparing the CSBQ with ADI-R, ADOS, and Clinical DSM-IV-TR Classification

    ERIC Educational Resources Information Center

    de Bildt, Annelies; Mulder, Erik J.; Hoekstra, Pieter J.; van Lang, Natasja D. J.; Minderaa, Ruud B.; Hartman, Catharina A.

    2009-01-01

    The Children's Social Behavior Questionnaire (CSBQ) was compared with the Autism Diagnostic Interview-Revised (ADI-R), Autism Diagnostic Observation Schedule (ADOS), and clinical classification in children with mild and moderate intellectual disability (ID), to investigate its criterion related validity. The contribution of the CSBQ to a…

  19. Making the Transition from Diagnosis to Treatment-Planning: Validity, Reliability and Factor Structure of the Autism Spectrum Disorder Behaviour Checklist

    ERIC Educational Resources Information Center

    Bitsika, Vicki; Sharpley, Christopher F.

    2018-01-01

    The validity, reliability and factor structure of the Autism Spectrum Disorder Behaviour Checklist-Revised (ASDBC-R) were measured in a sample of 140 boys with Autism Spectrum Disorder (ASD) aged between 6 and 18 years. Internal consistency (Cronbach's alpha) was satisfactory and the ASDBC-R significantly correlated with the Social Responsiveness…

  20. The Relationship between SAT® Scores and Retention to the Second Year: 2008 SAT Validity Sample. Statistical Report 2012-1

    ERIC Educational Resources Information Center

    Mattern, Krista D.; Patterson, Brian F.

    2012-01-01

    The College Board formed a research consortium with four-year colleges and universities to build a national higher education database with the primary goal of validating the revised SAT®, which consists of three sections: critical reading (SAT-CR), mathematics (SAT-M), and writing (SAT-W), for use in college admission. A study by Mattern and…

Top