Albals, Dima; Heyden, Yvan Vander; Schmid, Martin G; Chankvetadze, Bezhan; Mangelings, Debby
2016-03-20
The screening part of an earlier defined chiral separation strategy in capillary electrochromatography (CEC) was used for the separation of ten cathinone- and amphetamine derivatives. They were analyzed using 4 polysaccharide-based chiral stationary phases (CSPs), containing cellulose tris(3,5-dimethylphenylcarbamate) (ODRH), amylose tris(3,5-dimethylphenylcarbamate) (ADH), amylose tris(5-chloro-2-methylphenylcarbamate) (LA2), and cellulose tris(4-chloro-3-methylphenylcarbamate) (LC4) as chiral selectors. After applying the screening to each compound, ADH and LC4 showed the highest success rate. In a second part of the study, a comparison between CEC and other analytical techniques used for chiral separations i.e., supercritical fluid chromatography (SFC), polar organic solvent chromatography (POSC), reversed-phase (RPLC) and normal-phase liquid chromatography (NPLC), was made. For this purpose, earlier defined screening approaches for each technique were applied to separate the 10 test substances. This allowed an overall comparison of the success rates of the screening steps of the 5 techniques for these compounds. The results showed that CEC had a similar enantioselectivity rate as NPLC and RPLC, producing the highest number of separations (9 out of 10 racemates). SFC resolved 7 compounds, while POSC gave only 2 separations. On the other hand, the baseline separation success rates for NPLC and RPLC was better than for CEC. For a second comparison, the same chiral stationary phases as in the CEC screening were also tested with all techniques at their specific screening conditions, which allowed a direct comparison of the performance of CEC versus the same CSPs in the other techniques. This comparison revealed that RPLC was able to separate all tested compounds, and also produced the highest number of baseline separations on the CSP that were used in the CEC screening step. CEC and NPLC showed the same success rate: nine out of ten substances were separated. When CEC and NPLC are combined, separation of the ten compounds can be achieved. SFC and POSC resolved eight and three compounds, respectively. POSC was the least attractive option as it expressed only limited enantioselectivity toward these compounds. Copyright © 2015 Elsevier B.V. All rights reserved.
29 CFR 2590.715-2713 - Coverage of preventive health services.
Code of Federal Regulations, 2013 CFR
2013-07-01
... care provider. While visiting the provider, the individual is screened for cholesterol abnormalities... the laboratory work of the cholesterol screening test. (ii) Conclusion. In this Example 1, the plan... the cholesterol screening test. Because the office visit is billed separately from the cholesterol...
29 CFR 2590.715-2713 - Coverage of preventive health services.
Code of Federal Regulations, 2012 CFR
2012-07-01
... care provider. While visiting the provider, the individual is screened for cholesterol abnormalities... the laboratory work of the cholesterol screening test. (ii) Conclusion. In this Example 1, the plan... the cholesterol screening test. Because the office visit is billed separately from the cholesterol...
26 CFR 54.9815-2713T - Coverage of preventive health services (temporary).
Code of Federal Regulations, 2012 CFR
2012-04-01
... care provider. While visiting the provider, the individual is screened for cholesterol abnormalities... the laboratory work of the cholesterol screening test. (ii) Conclusion. In this Example 1, the plan... the cholesterol screening test. Because the office visit is billed separately from the cholesterol...
Fabrication and test of inorganic/organic separators. [for silver zinc batteries
NASA Technical Reports Server (NTRS)
Smatko, J. S.
1974-01-01
Completion of testing and failure analysis of MDC 40 Ahr silver zinc cells containing largely inorganic separators was accomplished. The results showed that the wet stand and cycle life objectives of the silver zinc cell development program were accomplished. Building, testing and failure analysis of two plate cells employing three optimum separators selected on the basis of extensive screening tests, was performed. The best separator material as a result of these tests was doped calcium zirconate.
Separator development and testing of nickel-hydrogen cells
NASA Technical Reports Server (NTRS)
Gonzalez-Sanabria, O. D.; Manzo, M. A.
1984-01-01
The components, design, and operating characteristics of Ni-H2 cells batteries were improved. A separator development program was designed to develop a separator that is resistant to penetration by oxygen and loose active material from then nickel electrode, while retraining the required chemical and thermal stability, reservoir capability, and high ionic conductivity. The performance of the separators in terms of cell operating voltage was to at least match that of state-of-the-art separators while eliminating the separator problems. The separators were submitted to initial screening tests and those which successfully completed the tests were built into Ni-H2 cells for short term testing. The separators with the best performance are tested for long term performance and life.
Pilot trial on separation conditions for diaper recycling.
Kim, Kyung-Shin; Cho, Hee-Sun
2017-09-01
By utilizing laboratory-scale tests, the optimal separation conditions for diaper recycling were identified, and then, these conditions were validated by a pilot trial. In this research, we determined the mass balances derived during various processing steps and identified the most feasible procedures to use for separating each material in the output flow. The results showed that drum screening was not able to remove all the fiber and super absorbent particles (SAP) in the plastic-rich fraction and that cellulose enzyme treatment can be a good solution. To achieve better separation of fibers and SAP, slot screening followed by a cleaner is a potential option. A feasible diaper recycling process was recommended based on these results. This process involves screening and enzymatic treatment for the plastic fraction, and screening, cleaning, and thickening for the fiber fraction. Treatment procedures were also proposed for the SAP fraction and rejected materials. Copyright © 2017. Published by Elsevier Ltd.
Detection of Sickle Cell Hemoglobin in Haiti by Genotyping and Hemoglobin Solubility Tests
Carter, Tamar E.; von Fricken, Michael; Romain, Jean R.; Memnon, Gladys; St. Victor, Yves; Schick, Laura; Okech, Bernard A.; Mulligan, Connie J.
2014-01-01
Sickle cell disease is a growing global health concern because infants born with the disorder in developing countries are now surviving longer with little access to diagnostic and management options. In Haiti, the current state of sickle cell disease/trait in the population is unclear. To inform future screening efforts in Haiti, we assayed sickle hemoglobin mutations using traditional hemoglobin solubility tests (HST) and add-on techniques, which incorporated spectrophotometry and insoluble hemoglobin separation. We also generated genotype data as a metric for HST performance. We found 19 of 202 individuals screened with HST were positive for sickle hemoglobin, five of whom did not carry the HbS allele. We show that spectrophotometry and insoluble hemoglobin separation add-on techniques could resolve false positives associated with the traditional HST approach, with some limitations. We also discuss the incorporation of insoluble hemoglobin separation observation with HST in suboptimal screening settings like Haiti. PMID:24957539
45 CFR 147.130 - Coverage of preventive health services.
Code of Federal Regulations, 2011 CFR
2011-10-01
... visiting the provider, the individual is screened for cholesterol abnormalities, which has in effect a... the cholesterol screening test. (ii) Conclusion. In this Example 1, the plan may not impose any cost-sharing requirements with respect to the separately-billed laboratory work of the cholesterol screening...
45 CFR 147.130 - Coverage of preventive health services.
Code of Federal Regulations, 2012 CFR
2012-10-01
... visiting the provider, the individual is screened for cholesterol abnormalities, which has in effect a... the cholesterol screening test. (ii) Conclusion. In this Example 1, the plan may not impose any cost-sharing requirements with respect to the separately-billed laboratory work of the cholesterol screening...
26 CFR 54.9815-2713T - Coverage of preventive health services (temporary).
Code of Federal Regulations, 2014 CFR
2014-04-01
... visiting the provider, the individual is screened for cholesterol abnormalities, which has in effect a... the cholesterol screening test. (ii) Conclusion. In this Example 1, the plan may not impose any cost-sharing requirements with respect to the separately-billed laboratory work of the cholesterol screening...
26 CFR 54.9815-2713T - Coverage of preventive health services (temporary).
Code of Federal Regulations, 2013 CFR
2013-04-01
... visiting the provider, the individual is screened for cholesterol abnormalities, which has in effect a... the cholesterol screening test. (ii) Conclusion. In this Example 1, the plan may not impose any cost-sharing requirements with respect to the separately-billed laboratory work of the cholesterol screening...
NASA Technical Reports Server (NTRS)
Green, Chris; Greenwell, Chris; Brusse, jay; Krus, Dennis; Leidecker, Henning
2009-01-01
During system level testing intermittent and permanent open circuit failures of mated, crimp removable, electrical contact pairs were experienced. The root cause of the failures was determined to be low (but not zero) contact forces applied by the socket contact tines against the engaging pin. The low contact force reduces the effectiveness of the wiping action of the socket tines against the pin. The observed failure mode may be produced when insufficient wiping during mate, demate and small relative movement in use allows for the accumulation of debris or insulating films that electrically separate the contact pair. The investigation identified at least three manufacturing process control problems associated with the socket contacts that enabled shipment of contacts susceptible to developing low contact forces: (1) Improper heat treatment of the socket tines resulting in plastic rather than elastic behavior; (2) Overly thinned socket tines at their base resulting in reduced pin retention forces; (3) insufficient screening tests to identify parts susceptible to the aforementioned failure mechanisms. The results from an extensive screening program of socket contacts utilizing the industry standard contact separation force test procedures are described herein. The investigation shows this method to be capable of identifying initially weak sockets. However, sockets whose contact retention forces may degrade during use may not be screened out by pin retention testing alone. Further investigations are required to correlate low contact retention forces with increased electrical contact resistance in the presence of insulating films that may accumulate in the use environment.
[A new system of testing visual performance based on the cylindrical lens screen].
Doege, E; Krause, O
1983-09-01
Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.
The Impact of the Affordable Care Act on Funding for Newborn Screening Services.
Costich, Julia F; Durst, Andrea L
2016-01-01
The Affordable Care Act requires most health plans to cover the federal Recommended Uniform Screening Panel of newborn screening (NBS) tests with no cost sharing. However, state NBS programs vary widely in both the number of mandated tests and their funding mechanisms, including a combination of state laboratory fees, third-party billing, and other federal and state funding. We assessed the potential impact of the Affordable Care Act coverage mandate on states' NBS funding. We performed an extensive review of the refereed literature, federal and state agency reports, relevant organizations' websites, and applicable state laws and regulations; interviewed 28 state and federal officials from August to December 2014; and then assessed the interview findings manually. Although a majority of states had well-established systems for including laboratory-based NBS tests in bundled charges for newborn care, billing practices for critical congenital heart disease and newborn hearing tests were less uniform. Most commonly, birthing facilities either prepaid the costs of laboratory-based tests when acquiring the filter paper kits, or the facilities paid for the tests when the kits were submitted. Some states had separate arrangements for billing Medicaid, and smaller facilities sometimes contracted with hearing test vendors that billed families separately. Although the Affordable Care Act coverage mandate may offset some state NBS funding for the screenings themselves, federal support is still required to assure access to the full range of NBS program services. Limiting reimbursement to the costs of screening tests alone would undermine the common practice of using screening charges to fund follow-up services counseling, and medical food or formula, particularly for low-income families.
Newborn screening: new developments, new dilemmas.
Kerruish, N J; Robertson, S P
2005-07-01
Scientific and technological advances are lending pressure to expand the scope of newborn screening. Whereas this has great potential for improving child health, it also challenges our current perception of such programmes. Standard newborn screening programmes are clearly justified by the fact that early detection and treatment of affected individuals avoids significant morbidity and mortality. However, proposals to expand the scope and complexity of such testing are not all supported by a similar level of evidence for unequivocal benefit. We argue that screening for genetic susceptibility to complex disorders is inherently different from standard screening and, while of potential value, must be considered separately from conventional testing.
High-throughput screening of chromatographic separations: II. Hydrophobic interaction.
Kramarczyk, Jack F; Kelley, Brian D; Coffman, Jonathan L
2008-07-01
A high-throughput screen (HTS) was developed to evaluate the selectivity of various hydrophobic interaction chromatography (HIC) resins for separating a mAb from aggregate species. Prior to the resin screen, the solubility of the protein was assessed to determine the allowable HIC operating region by examining 384 combinations of pH, salt, and protein concentration. The resin screen then incorporated 480 batch-binding and elution conditions with eight HIC resins in combination with six salts. The results from the screen were reproducible, and demonstrated quantitative recovery of the mAb and aggregate. The translation of the HTS batch-binding data to lab-scale chromatography columns was tested for four conditions spanning the range of product binding and selectivity. After accounting for the higher number of theoretical plates in the columns, the purity and recovery of the lab-scale column runs agreed with the HTS results demonstrating the predictive power of the filterplate system. The HTS data were further analyzed by the calculation of pertinent thermodynamic parameters such as the partition coefficient, K(P), and the separation factor, alpha. The separation factor was used to rank the purification capabilities of the resin and salt conditions explored. (c) 2008 Wiley Periodicals, Inc.
Evaluation of an enhanced gravity-based fine-coal circuit for high-sulfur coal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mohanty, M.K.; Samal, A.R.; Palit, A.
One of the main objectives of this study was to evaluate a fine-coal cleaning circuit using an enhanced gravity separator specifically for a high sulfur coal application. The evaluation not only included testing of individual unit operations used for fine-coal classification, cleaning and dewatering, but also included testing of the complete circuit simultaneously. At a scale of nearly 2 t/h, two alternative circuits were evaluated to clean a minus 0.6-mm coal stream utilizing a 150-mm-diameter classifying cyclone, a linear screen having a projected surface area of 0.5 m{sup 2}, an enhanced gravity separator having a bowl diameter of 250 mmmore » and a screen-bowl centrifuge having a bowl diameter of 500 mm. The cleaning and dewatering components of both circuits were the same; however, one circuit used a classifying cyclone whereas the other used a linear screen as the classification device. An industrial size coal spiral was used to clean the 2- x 0.6-mm coal size fraction for each circuit to estimate the performance of a complete fine-coal circuit cleaning a minus 2-mm particle size coal stream. The 'linear screen + enhanced gravity separator + screen-bowl circuit' provided superior sulfur and ash-cleaning performance to the alternative circuit that used a classifying cyclone in place of the linear screen. Based on these test data, it was estimated that the use of the recommended circuit to treat 50 t/h of minus 2-mm size coal having feed ash and sulfur contents of 33.9% and 3.28%, respectively, may produce nearly 28.3 t/h of clean coal with product ash and sulfur contents of 9.15% and 1.61 %, respectively.« less
Verification testing of the Brome Agri Sales Ltd. Maximizer Separator, Model MAX 1016 (Maximizer) was conducted at the Lake Wheeler Road Field Laboratory Swine Educational Unit in Raleigh, North Carolina. The Maximizer is an inclined screen solids separator that can be used to s...
Jana, Subrata; Samal, Prasanjit
2018-03-28
The range-separated hybrid density functionals are very successful in describing a wide range of molecular and solid-state properties accurately. In principle, such functionals are designed from spherically averaged or system averaged as well as reverse engineered exchange holes. In the present attempt, the screened range-separated hybrid functional scheme has been applied to the meta-GGA rung by using the density matrix expansion based semilocal exchange hole (or functional). The hybrid functional proposed here utilizes the spherically averaged density matrix expansion based exchange hole in the range separation scheme. For slowly varying density correction the range separation scheme is employed only through the local density approximation based exchange hole coupled with the corresponding fourth order gradient approximate Tao-Mo enhancement factor. The comprehensive testing and performance of the newly constructed functional indicates its applicability in describing several molecular properties. The most appealing feature of this present screened hybrid functional is that it will be practically very useful in describing solid-state properties at the meta-GGA level.
Verification testing of the Hoffland Drag Screen and Clarifier was conducted at the North Carolina State University's Lake Wheeler Road Field Laboratory, in Raleigh, North Carolina. The farm is designed to operate as a research and teaching facility with the capacity for 250 so...
Inorganic separator technology program
NASA Technical Reports Server (NTRS)
Smatko, J. S.; Weaver, R. D.; Kalhammer, F. R.
1973-01-01
Testing and failure analyses of silver zinc cells with largely inorganic separators were performed. The results showed that the wet stand and cycle life objective of the silver-zinc cell development program were essentially accomplished and led to recommendations for cell composition, design, and operation that should yield further improvement in wet and cycle life. A series of advanced inorganic materials was successfully developed and formulated into rigid and semiflexible separator samples. Suitable screening tests for evaluation of largely inorganic separators were selected and modified for application to the separator materials. The results showed that many of these formulations are potentially superior to previously used materials and permitted selection of three promising materials for further evaluation in silver-zinc cells.
Hierarchical screening for multiple mental disorders.
Batterham, Philip J; Calear, Alison L; Sunderland, Matthew; Carragher, Natacha; Christensen, Helen; Mackinnon, Andrew J
2013-10-01
There is a need for brief, accurate screening when assessing multiple mental disorders. Two-stage hierarchical screening, consisting of brief pre-screening followed by a battery of disorder-specific scales for those who meet diagnostic criteria, may increase the efficiency of screening without sacrificing precision. This study tested whether more efficient screening could be gained using two-stage hierarchical screening than by administering multiple separate tests. Two Australian adult samples (N=1990) with high rates of psychopathology were recruited using Facebook advertising to examine four methods of hierarchical screening for four mental disorders: major depressive disorder, generalised anxiety disorder, panic disorder and social phobia. Using K6 scores to determine whether full screening was required did not increase screening efficiency. However, pre-screening based on two decision tree approaches or item gating led to considerable reductions in the mean number of items presented per disorder screened, with estimated item reductions of up to 54%. The sensitivity of these hierarchical methods approached 100% relative to the full screening battery. Further testing of the hierarchical screening approach based on clinical criteria and in other samples is warranted. The results demonstrate that a two-phase hierarchical approach to screening multiple mental disorders leads to considerable increases efficiency gains without reducing accuracy. Screening programs should take advantage of prescreeners based on gating items or decision trees to reduce the burden on respondents. © 2013 Elsevier B.V. All rights reserved.
A Solution to Separation and Multicollinearity in Multiple Logistic Regression
Shen, Jianzhao; Gao, Sujuan
2010-01-01
In dementia screening tests, item selection for shortening an existing screening test can be achieved using multiple logistic regression. However, maximum likelihood estimates for such logistic regression models often experience serious bias or even non-existence because of separation and multicollinearity problems resulting from a large number of highly correlated items. Firth (1993, Biometrika, 80(1), 27–38) proposed a penalized likelihood estimator for generalized linear models and it was shown to reduce bias and the non-existence problems. The ridge regression has been used in logistic regression to stabilize the estimates in cases of multicollinearity. However, neither solves the problems for each other. In this paper, we propose a double penalized maximum likelihood estimator combining Firth’s penalized likelihood equation with a ridge parameter. We present a simulation study evaluating the empirical performance of the double penalized likelihood estimator in small to moderate sample sizes. We demonstrate the proposed approach using a current screening data from a community-based dementia study. PMID:20376286
A Solution to Separation and Multicollinearity in Multiple Logistic Regression.
Shen, Jianzhao; Gao, Sujuan
2008-10-01
In dementia screening tests, item selection for shortening an existing screening test can be achieved using multiple logistic regression. However, maximum likelihood estimates for such logistic regression models often experience serious bias or even non-existence because of separation and multicollinearity problems resulting from a large number of highly correlated items. Firth (1993, Biometrika, 80(1), 27-38) proposed a penalized likelihood estimator for generalized linear models and it was shown to reduce bias and the non-existence problems. The ridge regression has been used in logistic regression to stabilize the estimates in cases of multicollinearity. However, neither solves the problems for each other. In this paper, we propose a double penalized maximum likelihood estimator combining Firth's penalized likelihood equation with a ridge parameter. We present a simulation study evaluating the empirical performance of the double penalized likelihood estimator in small to moderate sample sizes. We demonstrate the proposed approach using a current screening data from a community-based dementia study.
Silvestre, Maria Asuncion A; Dans, Leonila F; Dans, Antonio L
2011-03-01
Evidence on the effectiveness of health screening strategies may be direct (i.e., studies on screening vs. no screening) or indirect (i.e., studies that separately evaluate the screening test[s], the confirmatory test, or the treatment). Critical trade-offs in the balance between harm and benefit for many screening strategies mandate that advocates of health screening adhere to the ethical precepts of nonmaleficence, autonomy, confidentiality, and equity. In our first article, we pointed out five prerequisites to justifying a health screening program: (1) the burden of illness should be high, (2) the screening and confirmatory tests should be accurate, (3) early treatment (or prevention) must be more effective than late treatment, (4) the tests and the treatment(s) must be safe, and (5) the cost of the screening strategy must be commensurate with the potential benefit. As can be gleaned from these criteria, recommendations on screening must be tailored to specific populations. Recommendations in one country, no matter how authoritative, cannot be generalized to apply to all other countries. Although accuracy, effectiveness, and safety data may be global (criteria 2-4), burden of illness and efficiency (criteria 1 and 5) will always vary from country to country. Rather than review various national guidelines, in this last article of our two-part series, we present evidence summaries to illustrate health screening. Our examples were selected to address special issues related to four situations-screening for cancer, risk factors for disease, genetic disorders, and infectious diseases. Copyright © 2011 Elsevier Inc. All rights reserved.
Polyvinyl alcohol membranes as alkaline battery separators
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Gonzalez-Sanabria, O.; Manzo, M. A.
1982-01-01
Polyvinly alcohol (PVA) cross-linked with aldehyde reagents yields membranes that demonstrate properties that make them suitable for use as alkaline battery separators. Film properties can be controlled by the choice of cross-linker, cross-link density and the method of cross-linking. Three methods of cross-linking and their effects on film properties are discussed. Film properties can also be modified by using a copolymer of vinyl alcohol and acrylic acid as the base for the separator and cross-linking it similarly to the PVA. Fillers can be incorporated into the films to further modify film properties. Results of separator screening tests and cell tests for several variations of PBA films are discussed.
Technologies for Decreasing Mining Losses
NASA Astrophysics Data System (ADS)
Valgma, Ingo; Väizene, Vivika; Kolats, Margit; Saarnak, Martin
2013-12-01
In case of stratified deposits like oil shale deposit in Estonia, mining losses depend on mining technologies. Current research focuses on extraction and separation possibilities of mineral resources. Selective mining, selective crushing and separation tests have been performed, showing possibilities of decreasing mining losses. Rock crushing and screening process simulations were used for optimizing rock fractions. In addition mine backfilling, fine separation, and optimized drilling and blasting have been analyzed. All tested methods show potential and depend on mineral usage. Usage in addition depends on the utilization technology. The questions like stability of the material flow and influences of the quality fluctuations to the final yield are raised.
NASA Technical Reports Server (NTRS)
Marroquin, J.; Kingsland, R. B.
1985-01-01
An experimental investigation was conducted in the NASA/Ames Research Center 2x2-foot Transonic Wind Tunnel to evaluate two AFRSI rewaterproofing systems and to investigate films as a means of reducing blanket joint distortion. The wind tunnel wall slot configuration influenced on the flow field over the test panel was investigated; primarily using oil flow data, and resulted in a closed slot configuration to provide a satisfactory screening environment flow field for the test. Sixteen AFRSI test panels, configured to represent the test system or film, were subjected to this screening environment (a flow field of separated and reattached flow at a freestream Mach numnber of 0.65 and q = 650 or 900 psf). Each condition was held until damage to the test article was observed or 55 minutes if no damage was incurred. All objectives related to AFRSI rewaterproofing and to the use of films to stiffen the blanket fibers were achieved.
Controversies in colorectal cancer screening.
Pox, Christian P
2014-01-01
Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.
Experimental design methodologies in the optimization of chiral CE or CEC separations: an overview.
Dejaegher, Bieke; Mangelings, Debby; Vander Heyden, Yvan
2013-01-01
In this chapter, an overview of experimental designs to develop chiral capillary electrophoresis (CE) and capillary electrochromatographic (CEC) methods is presented. Method development is generally divided into technique selection, method optimization, and method validation. In the method optimization part, often two phases can be distinguished, i.e., a screening and an optimization phase. In method validation, the method is evaluated on its fit for purpose. A validation item, also applying experimental designs, is robustness testing. In the screening phase and in robustness testing, screening designs are applied. During the optimization phase, response surface designs are used. The different design types and their application steps are discussed in this chapter and illustrated by examples of chiral CE and CEC methods.
Meniscus Membranes For Separation
Dye, Robert C.; Jorgensen, Betty; Pesiri, David R.
2005-09-20
Gas separation membranes, especially meniscus-shaped membranes for gas separations are disclosed together with the use of such meniscus-shaped membranes for applications such as thermal gas valves, pre-concentration of a gas stream, and selective pre-screening of a gas stream. In addition, a rapid screening system for simultaneously screening polymer materials for effectiveness in gas separation is provided.
Performance Gains of Propellant Management Devices for Liquid Hydrogen Depots
NASA Technical Reports Server (NTRS)
Hartwig, Jason W.; McQuillen, John B.; Chato, David J.
2013-01-01
This paper presents background, experimental design, and preliminary experimental results for the liquid hydrogen bubble point tests conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to investigate the parameters that affect liquid acquisition device (LAD) performance in a liquid hydrogen (LH2) propellant tank, to mitigate risk in the final design of the LAD for the Cryogenic Propellant Storage and Transfer Technology Demonstration Mission, and to provide insight into optimal LAD operation for future LH2 depots. Preliminary test results show an increase in performance and screen retention over the low reference LH2 bubble point value for a 325 2300 screen in three separate ways, thus improving fundamental LH2 LAD performance. By using a finer mesh screen, operating at a colder liquid temperature, and pressurizing with a noncondensible pressurant gas, a significant increase in margin is achieved in bubble point pressure for LH2 screen channel LADs.
Structure of Enhanced Cued Recall Task in the 7 Minute Screen Test.
Mora-Simon, Sara; Ladera-Fernandez, Valentina; Garcia-Garcia, Ricardo; Patino-Alonso, María C; Perea-Bartolome, M Victoria; Unzueta-Arce, Jaime; Perez-Arechaederra, Diana; Rodriguez-Sanchez, Emiliano
2017-01-01
Episodic memory in the 7 Minute Screen is assessed by the Enhanced Cued Recall (ECR) test. The ECR test is composed of three phases, Identification, Immediate Recall, and Free and Cued Recall. However, just the last phase is considered for the total score. We believe that collecting the performance data of the Identification and Immediate Recall phases could provide information regarding possible difficulties or impairments in the different aspects involved in the temporal mnesic process of acquisition of new information, such as in working memory or visual identification. The objective was to assess the goodness of fit for the three phases of the ECR test using a Confirmatory Factor Analysis (CFA) to show if each phase is separated from each other as a different aspect that participates in the mnesic process. A total of 311 participants greater than 65 years were included in this study. Confirmatory factor analyses were conducted for each individual phase. The analyses show that the ECR test consists of three separate phases that identify different steps of the mnesic process. Individual scores for each phase could allow for investigation of patient performance in different aspects of the memory process and could help in further neuropsychological assessment.
Van Norman, Ethan R; Nelson, Peter M; Klingbeil, David A
2017-09-01
Educators need recommendations to improve screening practices without limiting students' instructional opportunities. Repurposing previous years' state test scores has shown promise in identifying at-risk students within multitiered systems of support. However, researchers have not directly compared the diagnostic accuracy of previous years' state test scores with data collected during fall screening periods to identify at-risk students. In addition, the benefit of using previous state test scores in conjunction with data from a separate measure to identify at-risk students has not been explored. The diagnostic accuracy of 3 types of screening approaches were tested to predict proficiency on end-of-year high-stakes assessments: state test data obtained during the previous year, data from a different measure administered in the fall, and both measures combined (i.e., a gated model). Extant reading and math data (N = 2,996) from 10 schools in the Midwest were analyzed. When used alone, both measures yielded similar sensitivity and specificity values. The gated model yielded superior specificity values compared with using either measure alone, at the expense of sensitivity. Implications, limitations, and ideas for future research are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Cross-linked polyvinyl alcohol films as alkaline battery separators
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Manzo, M. A.; Gonzalez-Sanabria, O. D.
1983-01-01
Cross-linking methods have been investigated to determine their effect on the performance of polyvinyl alcohol (PVA) films as alkaline battery separators. The following types of cross-linked PVA films are discussed: (1) PVA-dialdehyde blends post-treated with an acid or acid periodate solution (two-step method) and (2) PVA-dialdehyde blends cross-linked during film formation (drying) by using a reagent with both aldehyde and acid functionality (one-step method). Laboratory samples of each cross-linked type of film were prepared and evaluated in standard separator screening tests. Then pilot-plant batches of films were prepared and compared to measure differences due to the cross-linking method. The pilot-plant materials were then tested in nickel oxide-zinc cells to compare the two methods with respect to performance characteristics and cycle life. Cell test results are compared with those from tests with Celgard.
Cross-linked polyvinyl alcohol films as alkaline battery separators
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Manzo, M. A.; Gonzalez-Sanabria, O. D.
1982-01-01
Cross-linking methods were investigated to determine their effect on the performance of polyvinyl alcohol (PVA) films as alkaline battery separators. The following types of cross-linked PVA films are discussed: (1) PVA-dialdehyde blends post-treated with an acid or acid periodate solution (two-step method) and (2) PVA-dialdehyde blends cross-linked during film formation (drying) by using a reagent with both aldehyde and acid functionality (one-step method). Laboratory samples of each cross-linked type of film were prepared and evaluated in standard separator screening tests. The pilot-plant batches of films were prepared and compared to measure differences due to the cross-linking method. The pilot-plant materials were then tested in nickel oxide - zinc cells to compare the two methods with respect to performance characteristics and cycle life. Cell test results are compared with those from tests with Celgard.
Cancer Screening Awareness and Practice in a Middle Income Country; A Systematic Review from Iran
Majidi, Azam; Majidi, Somayye; Salimzadeh, Somayye; Khazaee- Pool, Maryam; Sadjadi, Alireza; Salimzadeh, Hamideh; Delavari, Alireza
2017-12-28
Objective: Ageing population and noticeable changes in lifestyle in developing countries like Iran caused an increase in cancer incidence. This requires organized cancer prevention and screening programs in population level, but most importantly community should be aware of these programs and willing to use them. This study explored existing evidence on public awareness and practice, as well as, adherence to cancer screening in Iranian population. Methods: Major English databases including Web of Science, PubMed, Scopus, and domestic Persian databases i.e., SID, Magiran, and Barakat search engines were searched. All publications with focus on Iranian public awareness about cancer prevention, screening, and early detection programs which were published until August 2015, were explored in this systematic review. For this purpose, we used sensitive Persian phrases/key terms and English keywords which were extracted from medical subject headings (MeSH). Taking PRISMA guidelines into considerations eligible documents, were evaluated and abstracted by two separate reviewers. Results: We found 72 articles relevant to this topic. Screening tests were known to, or being utilized by only a limited number of Iranians. Most Iranian women relied on physical examination particularly self-examination, instead of taking mammogram, as the most standard test to find breast tumors. Less than half of the average-risk adult populations were familiar with colorectal cancer risk factors and its screening tests, and only very limited number of studies reported taking at least one time colonoscopy or FOBT, at most 5.0% and 15.0%, respectively. Around half of women were familiar with cervical cancer and Pap-smear test with less than 45% having completed at least one lifetime test. The lack of health insurance coverage was a barrier to participate in screening tests. Furthermore some people would not select to be screened only because they do not know how or where they can receive these services. Conclusion: Low awareness and suboptimal use of screening tests in Iran calls for effective programs to enhance intention and compliance to screening, improving the patient-physician communication, identifying barriers for screening and providing tailored public awareness and screening programs. Creative Commons Attribution License
Microgravity Passive Phase Separator
NASA Technical Reports Server (NTRS)
Paragano, Matthew; Indoe, William; Darmetko, Jeffrey
2012-01-01
A new invention disclosure discusses a structure and process for separating gas from liquids in microgravity. The Microgravity Passive Phase Separator consists of two concentric, pleated, woven stainless- steel screens (25-micrometer nominal pore) with an axial inlet, and an annular outlet between both screens (see figure). Water enters at one end of the center screen at high velocity, eventually passing through the inner screen and out through the annular exit. As gas is introduced into the flow stream, the drag force exerted on the bubble pushes it downstream until flow stagnation or until it reaches an equilibrium point between the surface tension holding bubble to the screen and the drag force. Gas bubbles of a given size will form a front that is moved further down the length of the inner screen with increasing velocity. As more bubbles are added, the front location will remain fixed, but additional bubbles will move to the end of the unit, eventually coming to rest in the large cavity between the unit housing and the outer screen (storage area). Owing to the small size of the pores and the hydrophilic nature of the screen material, gas does not pass through the screen and is retained within the unit for emptying during ground processing. If debris is picked up on the screen, the area closest to the inlet will become clogged, so high-velocity flow will persist farther down the length of the center screen, pushing the bubble front further from the inlet of the inner screen. It is desired to keep the velocity high enough so that, for any bubble size, an area of clean screen exists between the bubbles and the debris. The primary benefits of this innovation are the lack of any need for additional power, strip gas, or location for venting the separated gas. As the unit contains no membrane, the transport fluid will not be lost due to evaporation in the process of gas separation. Separation is performed with relatively low pressure drop based on the large surface area of the separating screen. Additionally, there are no moving parts, and there are no failure modes that involve fluid loss. A patent application has been filed.
Kutlay, Sehim; Kuçukdeveci, Ayse A; Elhan, Atilla H; Yavuzer, Gunes; Tennant, Alan
2007-02-28
Assessment of cognitive impairment with a valid cognitive screening tool is essential in neurorehabilitation. The aim of this study was to test the reliability and validity of the Turkish-adapted version of the Middlesex Elderly Assessment of Mental State (MEAMS) among acquired brain injury patients in Turkey. Some 155 patients with acquired brain injury admitted for rehabilitation were assessed by the adapted version of MEAMS at admission and discharge. Reliability was tested by internal consistency, intra-class correlation coefficient (ICC) and person separation index; internal construct validity by Rasch analysis; external construct validity by associations with physical and cognitive disability (FIM); and responsiveness by Effect Size. Reliability was found to be good with Cronbach's alpha of 0.82 at both admission and discharge; and likewise an ICC of 0.80. Person separation index was 0.813. Internal construct validity was good by fit of the data to the Rasch model (mean item fit -0.178; SD 1.019). Items were substantially free of differential item functioning. External construct validity was confirmed by expected associations with physical and cognitive disability. Effect size was 0.42 compared with 0.22 for cognitive FIM. The reliability and validity of the Turkish version of MEAMS as a cognitive impairment screening tool in acquired brain injury has been demonstrated.
Gent, M R; Menéndez, M; Muñiz, H; Torno, S
2015-09-01
A compilation of the physical properties of materials which might typically occur in automobile shredder residue and an analysis of their suitability for the separation of materials in fine (<15mm) heavy fluff ASR (fhf-ASR) is presented. Differences in density and resistance to crushing of fhf-ASR materials were identified as potentially the most suitable low cost, technologically simple means for the separating this waste into its three principal components - metals, minerals (glass/stones) and organics (plastics). Results presented of laboratory scale tests demonstrate that fhf-ASR can in large part be separated into three principal components. Tests were conducted with 0.63-2.0mm and 2-10mm fractions. Recovery of plastics by density separations were conducted with water only jigs for the 2-10mm fraction and shaker tables for the 0.63-2mm fraction. Comparisons are presented of the separations of glass and stones from metals obtained by linear screening and vibratory screening of roller mill and impact mill crushing products of the high density 2-10mm fraction. Equipment used for these tests are of a laboratory or demonstrative scale. It is reasonable to anticipate that industrial scale processing would produce significantly better results. The 2-15mm fraction was found to constitute 91.6% of the fhf-ASR sampled. The metals content of the 2-10mm portion of this fraction was upgraded from 2.5% to 31% and 76.9% with recoveries varying inversely with grade from 91.9% to 40.1%. From 63.6% to 17.1% with a recovery of 93.5% of the organic materials. A residual product of fine sand of crushed glass/stones of 99.4% purity recovered 71.3% of these. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Wilkinson, W. H.; Kirkhart, F. P.; Kistler, C. W.; Duckworth, W. H.; Ungar, E. W.; Foster, E. L.
1970-01-01
Technical problems of design and flight qualification of the proposed classes of surface insulation materials and leading edge materials were reviewed. A screening test plan, a preliminary design data test plan and a design data test plan were outlined. This program defined the apparent critical differences between the surface insulators and the leading edge materials, structuring specialized screening test plans for each of these two classes of materials. Unique testing techniques were shown to be important in evaluating the structural interaction aspects of the surface insulators and a separate task was defined to validate the test plan. In addition, a compilation was made of available information on proposed material (including metallic TPS), previous shuttle programs, pertinent test procedures, and other national programs of merit. This material was collected and summarized in an informally structured workbook.
The use of acid phosphatase test papers for DNA profiling.
Reshef, A; Barash, M; Gallili, N; Michael, A; Brauner, P
2005-01-01
The acid phosphatase (AP) test is a routine assay used to screen casework items for the possible presence of semen. This colour test is carried out on filter paper which is retained after testing. Two-year-old AP test papers were found to contain sufficient DNA for short tandem repeat (STR) profiling. Prior to polymerase chain reaction (PCR) amplification, the DNA was preferentially separated into sperm depleted and sperm enriched cell fractions. The implication of these findings for past and present cases is discussed.
Study of vapor flow into a capillary acquisition device. [for cryogenic rocket propellants
NASA Technical Reports Server (NTRS)
Dodge, F. T.; Bowles, E. B.
1982-01-01
An analytical model was developed that prescribes the conditions for vapor flow through the window screen of a start basket. Several original submodels were developed as part of this model. The submodels interrelate such phenomena as the effect of internal evaporation of the liquid, the bubble point change of a screen in the presence of wicking, the conditions for drying out of a screen through a combination of evaporation and pressure difference, the vapor inflow rate across a wet screen as a function of pressure difference, and the effect on wicking of a difference between the static pressure of the liquid reservoir and the surrounding vapor. Most of these interrelations were verified by a series of separate effects tests, which were also used to determine certain empirical constants in the models. The equations of the model were solved numerically for typical start basket designs, and a simplified start basket was constructed to verify the predictions, using both volatile and nonvolatile test liquids. The test results verified the trends predicted by the model.
Fernández, Maria E.; Diamond, Pamela M.; Rakowski, William; Gonzales, Alicia; Tortolero-Luna, Guillermo; Williams, Janet; Morales-Campos, Daisy Y.
2011-01-01
While self-efficacy (SE), a construct from Social Cognitive Theory, has been shown to influence other screening behaviors, few measures currently exist for measuring Pap test SE. This paper describes the development and psychometric testing of such a measure for Mexican-American women. Data from two separate samples of Mexican-American women 50 years or older, obtained as part of a study to develop and evaluate a breast and cervical cancer screening educational program, were used in the current study. Exploratory factor analysis indicated a single factor solution and all item loadings were > .73. Confirmatory analysis confirmed a single factor structure with all standardized loadings greater than .40 as hypothesized. The eight item SE scale demonstrated high internal consistency (Cronbach's alpha = .95). As hypothesized, SE was correlated with knowledge, prior experience, and screening intention. Logistic regression supported the theoretical relationship that women with higher SE were more likely to have had a recent Pap test. Findings showed a significant increase in SE following the intervention, indicating the measure has good sensitivity to change over time. PMID:19258484
Ultra high bypass Nacelle aerodynamics inlet flow-through high angle of attack distortion test
NASA Technical Reports Server (NTRS)
Larkin, Michael J.; Schweiger, Paul S.
1992-01-01
A flow-through inlet test program was conducted to evaluate inlet test methods and determine the impact of the fan on inlet separation when operating at large angles of attack. A total of 16 model configurations of approximately 1/6 scale were tested. A comparison of these flow-through results with powered data indicates the presence of the fan increased separation operation 3 degrees to 4 degrees over the flow through inlet. Rods and screens located at the fan face station, that redistribute the flow, achieved simulation of the powered-fan results for separation angle of attack. Concepts to reduce inlet distortion and increase angle of attack capability were also evaluated. Vortex generators located on the inlet surface increased inlet angle of attack capability up to 2 degrees and reduced inlet distortion in the separated region. Finally, a method of simulating the fan/inlet aerodynamic interaction using blockage sizing method has been defined. With this method, a static blockage device used with a flow-through model will approximate the same inlet onset of separation angle of attack and distortion pattern that would be obtained with an inlet model containing a powered fan.
Removal of batteries from solid waste using trommel separation.
Lau, S T; Cheung, W H; Kwong, C K; Wan, C P; Choy, K K H; Leung, C C; Porter, J F; Hui, C W; Mc Kay, G
2005-01-01
This paper describes the design and testing of a trommel for separation of batteries from solid waste. A trommel is a cylindrical separation device that rotates and performs size separation. It has also been used in areas such as municipal solid waste (MSW) processing, classifying construction and demolition debris, screening mass-burn incinerator ash and compost processing. A trommel has been designed based on size separation to separate household batteries from solid waste, which can then be used as feedstock for alternative applications of solid waste combustion, particularly where the metal content of the product is also a critical parameter, such as the Co-Co process for integrated cement and power production. This trommel has been tested with batches of university office and restaurant wastes against various factors. The recovery efficiency of batteries increases with decreasing inclination angle of the trommel and decreasing rotational speed. A physical characterization of the university solid waste has been performed with a 20-kg sample of the tested waste. It was found that there is a trend of decreasing recovery of batteries with increasing paper composition, and a trend of increasing recovery of batteries with increasing organic materials composition.
Dual laser optical system and method for studying fluid flow
NASA Technical Reports Server (NTRS)
Owen, R. B.; Witherow, W. K. (Inventor)
1983-01-01
A dual laser optical system and method is disclosed for visualization of phenomena in transport substances which induce refractive index gradients such as fluid flow and pressure and temperature gradients in fluids and gases. Two images representing mutually perpendicular components of refractive index gradients may be viewed simultaneously on screen. Two lasers having wave lengths in the visible range but separated by about 1000 angstroms are utilized to provide beams which are collimated into a beam containing components of the different wave lengths. The collimated beam is passed through a test volume of the transparent substance. The collimated beam is then separated into components of the different wave lengths and focused onto a pair of knife edges arranged mutually perpendicular to produce and project images onto the screen.
Colorectal cancer screening of immigrants to Italy. Figures from the 2013 National Survey.
Turrin, Anna; Zorzi, Manuel; Giorgi Rossi, Paolo; Senore, Carlo; Campari, Cinzia; Fedato, Chiara; Naldoni, Carlo; Anghinoni, Emanuela; Carrozzi, Giuliano; Sassoli De' Bianchi, Priscilla; Zappa, Marco
2015-12-01
Colorectal cancer screening programmes in Italy invite 50-69-year-old residents for a faecal immunochemical test every two years, regardless of their citizenship. The 2013 National Survey on Italian colorectal cancer screening programmes compared immigrants born in low- or middle-income countries with subjects who were born in Italy, by collecting aggregated data on compliance, faecal immunochemical test results, compliance with colonoscopy, detected lesions and stage at diagnosis separately for Italians and immigrants. Overall, 85 screening programmes invited 3,292,451 subjects, of whom 192,629 had been born abroad (5.9%). Compliance with invitation was lower in immigrants (34.3% vs. 51.3% in Italians), with p<0.001. Compliance was higher in females, regardless of the country of birth, in the youngest age group of immigrants but in the oldest of Italians. Immigrants showed a borderline excess of standardised faecal immunochemical test positivity rate at first screening (5.4% vs. 5.1% in Italians, p=0.05) and a significant excess at repeat screenings (4.8% vs. 4.4%, p=0.002). The detection rates for carcinoma and advanced adenomas were lower in immigrants than in Italians at first screening (respectively 1.34‰ vs. 1.62‰ and 8.41‰ vs. 9.25‰) - although the differences were not statistically significant - but not at repeat screening (respectively 1.06‰ vs. 0.98‰ and 6.90‰ vs. 6.79‰). Migrants showed a lower compliance with screening than Italians. The prevalence of neoplasia was lower at first screening and similar to the Italians' at repeat screenings. Copyright © 2015 Elsevier Inc. All rights reserved.
Jones, Loretta; Bazargan, Mohsen; Lucas-Wright, Anna; Vadgama, Jaydutt V; Vargas, Roberto; Smith, James; Otoukesh, Salman; Maxwell, Annette E
2013-01-01
Most theoretical formulations acknowledge that knowledge and awareness of cancer screening and prevention recommendations significantly influence health behaviors. This study compares perceived knowledge of cancer prevention and screening with test-based knowledge in a community sample. We also examine demographic variables and self-reported cancer screening and prevention behaviors as correlates of both knowledge scores, and consider whether cancer related knowledge can be accurately assessed using just a few, simple questions in a short and easy-to-complete survey. We used a community-partnered participatory research approach to develop our study aims and a survey. The study sample was composed of 180 predominantly African American and Hispanic community individuals who participated in a full-day cancer prevention and screening promotion conference in South Los Angeles, California, on July 2011. Participants completed a self-administered survey in English or Spanish at the beginning of the conference. Our data indicate that perceived and test-based knowledge scores are only moderately correlated. Perceived knowledge score shows a stronger association with demographic characteristics and other cancer related variables than the test-based score. Thirteen out of twenty variables that are examined in our study showed a statistically significant correlation with the perceived knowledge score, however, only four variables demonstrated a statistically significant correlation with the test-based knowledge score. Perceived knowledge of cancer prevention and screening was assessed with fewer items than test-based knowledge. Thus, using this assessment could potentially reduce respondent burden. However, our data demonstrate that perceived and test-based knowledge are separate constructs.
Development and evaluation of polyvinyl-alcohol blend polymer films as battery separators
NASA Technical Reports Server (NTRS)
Manzo, M. A.
1982-01-01
Several dialdehydes and epoxies were evaluated for their suitability as cross-linkers. Optium concentrations of several cross-linking reagents were determined. A two-step method of cross-linking, which involves treatment of the film in an acid or acid periodate bath, was investigated and dropped in favor of a one-step method in which the acid catalyst, which initiates cross-linking, is added to the PVA - cross-linker solution before casting. The cross-linking was thus achieved during the drying step. This one-step method was much more adaptable to commercial processing. Cross-linked films were characterized as alkaline battery separators. Films were prepared in the lab and tested in cells in order to evaluate the effect of film composition and a number of processing parameters on cell performance. These tests were conducted in order to provide a broader data base from which to select optimum processing parameters. Results of the separator screening tests and the cell tests are discussed.
Photographic Combustion Characterization of LOX/Hydrocarbon Type Propellants
NASA Technical Reports Server (NTRS)
Judd, D. C.
1980-01-01
The advantages and limitations of using high speed photography to identify potential combustion anomalies (pops, fuel freezing, reactive stream separation (RSS), carbon formation) were demonstrated. Combustion evaluation criteria were developed for evaluating, characterizing, and screening promising low cost propellant combination(s) and injector element(s) for long life, reusable engine systems. Carbon formation and RSS mechanisms and trends were identified by using high speed color photography at speeds up to 6000 frames/sec. Single element injectors were tested with LOX/RP-1, LOX/Propane, LOX/Methane and LOX/Ammonia propellants. Tests were conducted using seven separate injector elements. Five different conventionally machined elements were tested: OFO Triplet; Rectangular Unlike Doublet (RUD); Unlike Doublet (UD); Like on Lke Doublet (LOL-EDM); and Slit Triplet.
Eu, B; O'Neill, M J
1983-06-01
The present study was designed to validate and standardize a short psychomotor screening test on Australian four-year-old-preschool children and to assess their home environment using Caldwell's HOME Inventory. The Adelaide Psychomotor Screen (APS) is a short, 10-15 minute screening test which uses 13 separate items to assess "General" development, "Gross Motor" development, "Social/Emotional Behaviour" and "Speech". In the area of "General" development, 12 children screened as "abnormal" and 54 children screened as "normal" were further assessed by a psychologist on the McCarthy Scales of Children's Abilities. There was a high correlation between the APS "General" scores and the McCarthy (General Cognitive Index) scores (r = 0.75, p less than 0.001 for the younger children, and r = 0,90, p less than 0.001 for the older children). Caldwell's HOME Inventory takes an hour to complete, and involves a visit by the assessor to each home. The correlation between the HOME total scores and the McCarthy (General Cognitive Index) scores was r = 0.06, p less than 0.001. It is suggested that the HOME Inventory may be more valuable as a predictor of a child's future development than an index of his present developmental status. It is suggested that nurses and teachers used the APS as a screening test of the individual child, and use the HOME inventory as an assessment of the home environment.
Preschool visual acuity screening tests.
Friendly, D S
1978-01-01
The purpose of the study was to evaluate the relative merits of two screening tests used for visual acuity assessment of preschool children. The tests that were compared were the Good-Lite Company versions of the E-Test and of the STYCAR (Screening Test for Young Children and Retardates). The former is the most popular method for evaluating central acuity in young children in this nation; the STYCAR is a relatively new letter-matching-test developed in England, where it is widely employed. The E-Test poses left-right orientation problems which are eliminated by the symmetrical letters H, T, O and V utilized in the Letter-Matching-Test. Both visual acuity tests were administered on two separate occasions by personnel from the Prevention of Blindness Society of Metropolitan Washington to 633 preschool children in Washington, D.C. By random selection, 150 of the children received the E-Test at both sessions, 162 children received the Letter-Matching-Test at both sessions, 160 chilt athe the second session, and 161 children received the Letter-Matching-Test at the first session and the E-Test at the second session. The author medically examined the eyes of 408 of the 633 children without knowledge of which test had been initially administered. Statistical analysis of the data obtained from the study indicated that the Letter-Matching-Test was significantly better in terms of testability rates, group and individual instruction time, and performance time. The E-Test was more reliable in terms of test-retest acuity scores and was also more valid in terms of agreement between pass-fail results obtained at the first screening session and two levels of pass-fail refraction criteria. Images FIGURE 4 FIGURE 5 FIGURE 7 A FIGURE 7 B FIGURE 9 A FIGURE 9 B PMID:754379
Microfluidics for cell-based high throughput screening platforms - A review.
Du, Guansheng; Fang, Qun; den Toonder, Jaap M J
2016-01-15
In the last decades, the basic techniques of microfluidics for the study of cells such as cell culture, cell separation, and cell lysis, have been well developed. Based on cell handling techniques, microfluidics has been widely applied in the field of PCR (Polymerase Chain Reaction), immunoassays, organ-on-chip, stem cell research, and analysis and identification of circulating tumor cells. As a major step in drug discovery, high-throughput screening allows rapid analysis of thousands of chemical, biochemical, genetic or pharmacological tests in parallel. In this review, we summarize the application of microfluidics in cell-based high throughput screening. The screening methods mentioned in this paper include approaches using the perfusion flow mode, the droplet mode, and the microarray mode. We also discuss the future development of microfluidic based high throughput screening platform for drug discovery. Copyright © 2015 Elsevier B.V. All rights reserved.
Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L
2010-02-15
Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.
[Progresses in screening active compounds from herbal medicine by affinity chromatography].
Feng, Ying-shu; Tong, Shan-shan; Xu, Xi-ming; Yu, Jiang-nan
2015-03-01
Affinity chromatography is a chromatographic method for separating molecules using the binding characteristics of the stationary phase with potential drug molecules. This method can be performed as a high throughput screening method and a chromatographic separation method to screen a variety of active drugs. This paper summarizes the history of affinity chromatography, screening technology of affinity chromatography, and application of affinity chromatography in screening bio-active compounds in herbal medicines, and then discusses its application prospects, in order to broaden applications of the affinity chromatography in drug screening.
Holme, Øyvind; Bretthauer, Michael; Fretheim, Atle; Odgaard-Jensen, Jan; Hoff, Geir
2013-10-01
Colorectal cancer is the third most frequent cancer in the world. As the sojourn time for this cancer is several years and a good prognosis is associated with early stage diagnosis, screening has been implemented in a number of countries. Both screening with faecal occult blood test and flexible sigmoidoscopy have been shown to reduce mortality from colorectal cancer in randomised controlled trials. The comparative effectiveness of these tests on colorectal cancer mortality has, however, never been evaluated, and controversies exist over which test to choose. To compare the effectiveness of screening for colorectal cancer with flexible sigmoidoscopy to faecal occult blood testing. We searched MEDLINE and EMBASE (November 16, 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 11) and reference lists for eligible studies. Randomised controlled trials comparing screening with flexible sigmoidoscopy or faecal occult blood testing to each other or to no screening. Only studies reporting mortality from colorectal cancer were included. Faecal occult blood testing had to be repeated (annually or biennially). Data retrieval and assessment of risk of bias were performed independently by two review authors. Standard meta-analyses using a random-effects model were conducted for flexible sigmoidoscopy and faecal occult blood testing (FOBT) separately and we calculated relative risks with 95% confidence intervals (CI). We used a Bayesian approach (a contrast-based network meta-analysis method) for indirect analyses and presented the results as posterior median relative risk with 95% credibility intervals. We assessed the quality of evidence using GRADE. We identified nine studies comprising 338,467 individuals randomised to screening and 405,919 individuals to the control groups. Five studies compared flexible sigmoidoscopy to no screening and four studies compared repetitive guaiac-based FOBT (annually and biennially) to no screening. We did not consider that study risk of bias reduced our confidence in our results. We did not identify any studies comparing the two screening methods directly. When compared with no screening, colorectal cancer mortality was lower with flexible sigmoidoscopy (relative risk 0.72; 95% CI 0.65 to 0.79, high quality evidence) and FOBT (relative risk 0.86; 95% CI 0.80 to 0.92, high quality evidence). In the analyses based on indirect comparison of the two screening methods, the relative risk of dying from colorectal cancer was 0.85 (95% credibility interval 0.72 to 1.01, low quality evidence) for flexible sigmoidoscopy screening compared to FOBT. No complications occurred after the FOBT test itself, but 0.03% of participants suffered a major complication after follow-up. Among more than 60,000 flexible sigmoidoscopy screening procedures and almost 6000 work-up colonoscopies, a major complication was recorded in 0.08% of participants. Adverse event data should be interpreted with caution as the reporting of adverse effects was incomplete. There is high quality evidence that both flexible sigmoidoscopy and faecal occult blood testing reduce colorectal cancer mortality when applied as screening tools. There is low quality indirect evidence that screening with either approach reduces colorectal cancer deaths more than the other. Major complications associated with screening require validation from studies with more complete reporting of harms
Xu, Wendy Yi; Jung, Jeah Kyoungrae
2017-10-01
Consuming low-value health care not only highlights inefficient resource use but also brings an important concern regarding the economics of disparities. We identify the relation of socioeconomic characteristics to the use of low-value cancer screenings in Medicare fee-for-service (FFS) settings, and quantify the amount subsidized from nonusers and taxpayers to users of these screenings. 2007-2013 Medicare Current Beneficiary Survey, Medicare FFS claims, and the Area Health Resource Files. Our sample included enrollees in FFS Part B for the entire calendar year. We excluded beneficiaries with a claims-documented or self-reported history of targeted cancers, or those enrolled in Medicaid or Medicare Advantage plans. We identified use of low-value Pap smears, mammograms, and prostate-specific antigen tests based on established algorithms, and estimated a logistic model with year dummies separately for each test. Secondary data analyses. We found a statistically significant positive association between privileged socioeconomic characteristics and use of low-value screenings. Having higher income and supplemental private insurance strongly predicted more net subsidies from Medicare. FFS enrollees who are better off in terms of sociodemographic characteristics receive greater subsidies from taxpayers for using low-value cancer screenings. © Health Research and Educational Trust.
Quantifying the advantages and disadvantages of pre-placement genetic screening
Palmer, K; Poole, J; Rawbone, R; Coggon, D
2004-01-01
Background: Tests of genotype may enable workers at unusual risk of future ill-health to be identified. Using them to select for employment, however, entails gains and losses to employers and employees. Ensuring a fair balance between the rights and obligations of each group requires a value judgement, but the advantages and disadvantages to interested parties must first be quantified in a meaningful way. Method and Results: The purposes of pre-employment screening are reviewed, and several simple measures relevant to the separate interests of employers and job applicants proposed—number screened to prevent a single adverse outcome; number excluded to prevent a case; expected incidence of the adverse outcome in those excluded; and preventable fraction. The derivation of these measures is illustrated, and the factors that influence them (the prevalence of the prognostic trait, the relative risk that it carries for an adverse outcome, and the overall incidence of disease) are related algebraically and graphically, to aid judgement on the utility of screening under different circumstances. Conclusions: In sensitive areas such as genetic testing the onus should be on the employer to justify plans for pre-placement screening. Several quantitative measures can be used to inform the ethical and economic debate about screening and to evaluate alternative strategies for prevention. PMID:15090667
Quantifying the advantages and disadvantages of pre-placement genetic screening.
Palmer, K T; Poole, J; Rawbone, R G; Coggon, D
2004-05-01
Tests of genotype may enable workers at unusual risk of future ill-health to be identified. Using them to select for employment, however, entails gains and losses to employers and employees. Ensuring a fair balance between the rights and obligations of each group requires a value judgement, but the advantages and disadvantages to interested parties must first be quantified in a meaningful way. The purposes of pre-employment screening are reviewed, and several simple measures relevant to the separate interests of employers and job applicants proposed-number screened to prevent a single adverse outcome; number excluded to prevent a case; expected incidence of the adverse outcome in those excluded; and preventable fraction. The derivation of these measures is illustrated, and the factors that influence them (the prevalence of the prognostic trait, the relative risk that it carries for an adverse outcome, and the overall incidence of disease) are related algebraically and graphically, to aid judgement on the utility of screening under different circumstances. In sensitive areas such as genetic testing the onus should be on the employer to justify plans for pre-placement screening. Several quantitative measures can be used to inform the ethical and economic debate about screening and to evaluate alternative strategies for prevention.
Testing the reliability of the Fall Risk Screening Tool in an elderly ambulatory population.
Fielding, Susan J; McKay, Michael; Hyrkas, Kristiina
2013-11-01
To identify and test the reliability of a fall risk screening tool in an ambulatory outpatient clinic. The Fall Risk Screening Tool (Albert Lea Medical Center, MN, USA) was scripted for an interview format. Two interviewers separately screened a convenience sample of 111 patients (age ≥ 65 years) in an ambulatory outpatient clinic in a northeastern US city. The interviewers' scoring of fall risk categories was similar. There was good internal consistency (Cronbach's α = 0.834-0.889) and inter-rater reliability [intra-class correlation coefficients (ICC) = 0.824-0.881] for total, Risk Factor and Client's Health Status subscales. The Physical Environment scores indicated acceptable internal consistency (Cronbach's α = 0.742) and adequate reliability (ICC = 0.688). Two Physical Environment items (furniture and medical equipment condition) had low reliabilities [Kappa (K) = 0.323, P = 0.08; K = -0.078, P = 0.648), respectively. The scripted Fall Risk Screening Tool demonstrated good reliability in this sample. Rewording two Physical Environment items will be considered. A reliable instrument such as the scripted Fall Risk Screening Tool provides a standardised assessment for identifying high fall risk patients. This tool is especially useful because it assesses personal, behavioural and environmental factors specific to community-dwelling patients; the interview format also facilitates patient-provider interaction. © 2013 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Iek, Chanthy; Boldman, Donald R.; Ibrahim, Mounir
1993-01-01
A time marching Navier-Stokes code called PARC3D was used to study the 3-D viscous flow associated with an advanced ducted propeller (ADP) subsonic inlet at take-off operating conditions. At a free stream Mach number of 0.2, experimental data for the inlet-with-propeller test model indicated that the airflow was attached on the cowl windward lip at an angle of attack of 25 degrees became unstable at 29 degrees, and separated at 30 degrees. An experimental study with a similar inlet and with no propeller (through-flow) indicated that flow separation occurred at an angle of attack a few degrees below the value observed when the inlet was tested with the propeller. This tends to indicate that the propeller exerts a favorable effect on the inlet performance. During the through-flow experiment a stationary blockage device was used to successfully simulate the propeller effect on the inlet flow field at angles of attack. In the present numerical study, this flow blockage was modeled via a PARC3D computational boundary condition (BC) called the screen BC. The principle formulation of this BC was based on the one-and-half dimension actuator disk theory. This screen BC was applied at the inlet propeller face station of the computational grid. Numerical results were obtained with and without the screen BC. The application of the screen BC in this numerical study provided results which are similar to the results of past experimental efforts in which either the blockage device or the propeller was used.
NASA Technical Reports Server (NTRS)
Burley, Richard R.; Harrington, Douglas E.
1987-01-01
An experimental investigation was conducted in the high speed leg of the 0.1 scale model of the proposed Altitude Wind Tunnel to evaluate flow conditioner configurations in the settling chamber and their effect on the flow through the short contraction section. The lowest longitudinal turbulence intensity measured at the contraction-section entrance, 1.2%, was achieved with a honeycomb plus three fine-mesh screens. Turbulence intensity in the test section was estimated to be between 0.1 and 0.2% with the honeycomb plus three fine mesh screens in the settling chamber. Adding screens, however, adversely affected the total pressure profile, causing a small defect near the centerline at the contraction section entrance. No significant boundary layer separation was evident in the short contraction section.
Benn, Peter A; Makowski, Gregory S; Egan, James F X; Wright, Dave
2006-11-01
Analytical error affects 2nd-trimester maternal serum screening for Down syndrome risk estimation. We analyzed the between-laboratory reproducibility of risk estimates from 2 laboratories. Laboratory 1 used Bayer ACS180 immunoassays for alpha-fetoprotein (AFP) and human chorionic gonadotropin (hCG), Diagnostic Systems Laboratories (DSL) RIA for unconjugated estriol (uE3), and DSL enzyme immunoassay for inhibin-A (INH-A). Laboratory 2 used Beckman immunoassays for AFP, hCG, and uE3, and DSL enzyme immunoassay for INH-A. Analyte medians were separately established for each laboratory. We used the same computational algorithm for all risk calculations, and we used Monte Carlo methods for computer modeling. For 462 samples tested, risk figures from the 2 laboratories differed >2-fold for 44.7%, >5-fold for 7.1%, and >10-fold for 1.7%. Between-laboratory differences in analytes were greatest for uE3 and INH-A. The screen-positive rates were 9.3% for laboratory 1 and 11.5% for laboratory 2, with a significant difference in the patients identified as screen-positive vs screen-negative (McNemar test, P<0.001). Computer modeling confirmed the large between-laboratory risk differences. Differences in performance of assays and laboratory procedures can have a large effect on patient-specific risks. Screening laboratories should minimize test imprecision and ensure that each assay performs in a manner similar to that assumed in the risk computational algorithm.
Economic and workflow analysis of a blood bank automated system.
Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup
2013-07-01
This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.
Separate Flow Nozzle Test Status Meeting
NASA Technical Reports Server (NTRS)
Saiyed, Naseem H. (Editor)
2000-01-01
NASA Glenn, in partnership with US industry, completed an exhaustive experimental study on jet noise reduction from separate flow nozzle exhaust systems. The study developed a data base on various bypass ratio nozzles, screened quietest configurations and acquired pertinent data for predicting the plume behavior and ultimately its corresponding jet noise. Several exhaust system configurations provided over 2.5 EPNdB jet noise reduction at take-off power. These data were disseminated to US aerospace industry in a conference hosted by NASA GRC whose proceedings are shown in this report.
Silva, R; Dow, P; Dubay, R; Lissandrello, C; Holder, J; Densmore, D; Fiering, J
2017-09-01
Acoustic manipulation has emerged as a versatile method for microfluidic separation and concentration of particles and cells. Most recent demonstrations of the technology use piezoelectric actuators to excite resonant modes in silicon or glass microchannels. Here, we focus on acoustic manipulation in disposable, plastic microchannels in order to enable a low-cost processing tool for point-of-care diagnostics. Unfortunately, the performance of resonant acoustofluidic devices in plastic is hampered by a lack of a predictive model. In this paper, we build and test a plastic blood-bacteria separation device informed by a design of experiments approach, parametric rapid prototyping, and screening by image-processing. We demonstrate that the new device geometry can separate bacteria from blood while operating at 275% greater flow rate as well as reduce the power requirement by 82%, while maintaining equivalent separation performance and resolution when compared to the previously published plastic acoustofluidic separation device.
Dupont, S; De Spiegeleer, A; Liu, D J X; Lefère, L; van Doorn, D A; Hesta, M
2016-01-01
Commercial immunoglobulin E (IgE)-based tests are available for diagnosis of food allergies and are commonly used in equine practice. However, these tests have been proven unreliable as a screening method in man and other species, but not critically evaluated in equids. Therefore, a commercially available IgE-based test for horses was evaluated. To evaluate the consistency of the results obtained with a commercially available IgE-based test for food allergy diagnosis in ponies (Phase I) and to subject ponies to a provocation trial with the presumed allergens (Phase II). Allergen screening followed by experimental food provocation trials in healthy ponies. Blood samples of 17 healthy Shetland ponies were taken at 2 different time points, sent blinded to a commercial laboratory for screening of common food allergens and the results were evaluated for consistency (Phase I). Ponies that were positive for food allergens were consecutively challenged orally with each allergen separately for 14 days (Phase II). A washout period of one week was applied in ponies with multiple positive results. Clinical parameters and serum amyloid A were monitored during the provocation trial. Only 7/17 ponies were negative on the IgE-based test at the 2 time points, 3 had positive results twice but only one tested positive twice for the same food allergen. No abnormalities were noted during the provocation trials. This study demonstrated that this IgE-based test is not a reliable screening tool for food allergy in healthy equids. © 2015 EVJ Ltd.
NASA Technical Reports Server (NTRS)
Stallings, Robert L., Jr.; Wilcox, Floyd J., Jr.; Forrest, Dana K.
1991-01-01
An experimental investigation was conducted to measure the forces, moments, and pressure distributions on the generic store separating from a rectangular box cavity contained in a flat plate surface at supersonic speeds. Pressure distributions inside the cavity and oil flow and vapor-screen photographs of the cavity flow field were also obtained. The measurements were obtained for the store separating from a flat plate surface, from two shallow cavities having length to depth ratios (L/h) of 16.778 and 12.073, and from a deep cavity having L/h = 6.730. Measurements for the shallow cavities were obtained both with and without rectangular doors attached to sides of the cavities. The tests were conducted at free stream Mach numbers of 1.69, 2.00 and 2.65 for a free stream Reynolds number per foot of 2 x 10(exp 6). Presented here are a discussion of the results, a complete tabulation of the pressure data, figures of both the pressure and force and moment data, and representative oil flow and vapor screen photographs.
Katki, Hormuzd A; Schiffman, Mark
2018-05-01
Our work involves assessing whether new biomarkers might be useful for cervical-cancer screening across populations with different disease prevalences and biomarker distributions. When comparing across populations, we show that standard diagnostic accuracy statistics (predictive values, risk-differences, Youden's index and Area Under the Curve (AUC)) can easily be misinterpreted. We introduce an intuitively simple statistic for a 2 × 2 table, Mean Risk Stratification (MRS): the average change in risk (pre-test vs. post-test) revealed for tested individuals. High MRS implies better risk separation achieved by testing. MRS has 3 key advantages for comparing test performance across populations with different disease prevalences and biomarker distributions. First, MRS demonstrates that conventional predictive values and the risk-difference do not measure risk-stratification because they do not account for test-positivity rates. Second, Youden's index and AUC measure only multiplicative relative gains in risk-stratification: AUC = 0.6 achieves only 20% of maximum risk-stratification (AUC = 0.9 achieves 80%). Third, large relative gains in risk-stratification might not imply large absolute gains if disease is rare, demonstrating a "high-bar" to justify population-based screening for rare diseases such as cancer. We illustrate MRS by our experience comparing the performance of cervical-cancer screening tests in China vs. the USA. The test with the worst AUC = 0.72 in China (visual inspection with acetic acid) provides twice the risk-stratification (i.e. MRS) of the test with best AUC = 0.83 in the USA (human papillomavirus and Pap cotesting) because China has three times more cervical precancer/cancer. MRS could be routinely calculated to better understand the clinical/public-health implications of standard diagnostic accuracy statistics. Published by Elsevier Inc.
Effect of screens in wide-angle diffusers
NASA Technical Reports Server (NTRS)
Schubauer, G B; Spangenberg, W G
1949-01-01
An experimental investigation at low airspeeds was made of the filling effect observed when a screen or similar resistance is placed across a diffuser. The filling effect is found to be real in that screens can prevent separation or restore separated flow in diffusers even of extreme divergence and to depend principally on screen location and pressure-drop coefficient of the screen. Results are given for three different diffusers of circular cross section with a variety of screen arrangements. Effects of single screens and multiple screens are shown. The mechanics of the filling effect is explained, and possible efficiencies are discussed. Results of arrangements of multiple screens in wide-angle diffusers are given to show a possible application to damping screens as used in wind tunnels to reduce turbulence. (author)
Evaluation of the Microsoft Kinect for screening ACL injury.
Stone, Erik E; Butler, Michael; McRuer, Aaron; Gray, Aaron; Marks, Jeffrey; Skubic, Marjorie
2013-01-01
A study was conducted to evaluate the use of the skeletal model generated by the Microsoft Kinect SDK in capturing four biomechanical measures during the Drop Vertical Jump test. These measures, which include: knee valgus motion from initial contact to peak flexion, frontal plane knee angle at initial contact, frontal plane knee angle at peak flexion, and knee-to-ankle separation ratio at peak flexion, have proven to be useful in screening for future knee anterior cruciate ligament (ACL) injuries among female athletes. A marker-based Vicon motion capture system was used for ground truth. Results indicate that the Kinect skeletal model likely has acceptable accuracy for use as part of a screening tool to identify elevated risk for ACL injury.
[Quality assurance from the viewpoint of the x-ray film industry].
von Volkmann, T
1992-08-01
The parameters of a film-screen-combination are listed in the directive to section 16 of the german X-ray Regulation. These parameters are determined by methods described in DIN standards and published by the manufacturer. Comparable but less precise parameters are determined in the Acceptance Test. For physical reasons it is not possible to determine the speed of an X-ray film or the intensification factor of a screen separately. The films, screens and processing chemicals delivered by the members of the manufacturer association ZVEI are kept below a deviation (expressed as relative contribution to the system speed S) of +/- 10% for the majority of products, the upper limit is +/- 15%. Poor storage and transport conditions may adversely affect the quality of X-ray films. A special labeling of the film box shall serve to guarantee safe distribution channels. The processing conditions are adjusted at the Acceptance Test according to the manufacturers recommendations. The Constancy Test of film processing serves to maintain these correct conditions. Methods deviating from the DIN-method are of limited (Bayerische method) or no value (Stuttgart method).
Separation of organic ion exchange resins from sludge -- engineering study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duncan, J.B.
1998-08-25
This engineering study evaluates the use of physical separation technologies to separate organic ion exchange resin from KE Basin sludge prior to nitric acid dissolution. This separation is necessitate to prevent nitration of the organics in the acid dissolver. The technologies under consideration are: screening, sedimentation, elutriation. The recommended approach is to first screen the Sludge and resin 300 microns then subject the 300 microns plus material to elutriation.
Diagnostic characters within ITS2 DNA support molecular identification of Anastrepha suspensa
USDA-ARS?s Scientific Manuscript database
An approximately 220 bp fragment of the internal transcribed spacer 2 (ITS2) is screened as a diagnostic of Anastrepha suspensa and other pest fruit flies in the genus Anastrepha. The majority (96%) of the sites in this fragment are invariant among the test species but A. suspensa can be separated f...
Park, Hyun Young; Toume, Kazufumi; Arai, Midori A; Koyano, Takashi; Kowithayakorn, Thaworn; Ishibashi, Masami
2014-01-01
Screening with a cell-based luciferase assay was conducted to identify bioactive natural products which inhibit Wnt signaling activity-guided separation of an MeOH extract of Bauhinia malabarica (Caesalpiniaceae) leaves yielded five compounds, which were identified as β-sitosterol (1), quercetin (2), 6,8-C-dimethyl kaempferol-3-O-rhamnopyranoside (3), hyperin (4), and 6,8-C-dimethyl kaempferol-3-methyl ether (5). The tested compounds 1, 3, and 5 exhibited Wnt signaling inhibitory activity, with IC50 values of 0.77, 0.74, and 16.6 μM, respectively.
Can laptops be left inside passenger bags if motion imaging is used in X-ray security screening?
Mendes, Marcia; Schwaninger, Adrian; Michel, Stefan
2013-01-01
This paper describes a study where a new X-ray machine for security screening featuring motion imaging (i.e., 5 views of a bag are shown as an image sequence) was evaluated and compared to single view imaging available on conventional X-ray screening systems. More specifically, it was investigated whether with this new technology X-ray screening of passenger bags could be enhanced to such an extent that laptops could be left inside passenger bags, without causing a significant impairment in threat detection performance. An X-ray image interpretation test was created in four different versions, manipulating the factors packing condition (laptop and bag separate vs. laptop in bag) and display condition (single vs. motion imaging). There was a highly significant and large main effect of packing condition. When laptops and bags were screened separately, threat item detection was substantially higher. For display condition, a medium effect was observed. Detection could be slightly enhanced through the application of motion imaging. There was no interaction between display and packing condition, implying that the high negative effect of leaving laptops in passenger bags could not be fully compensated by motion imaging. Additional analyses were carried out to examine effects depending on different threat categories (guns, improvised explosive devices, knives, others), the placement of the threat items (in bag vs. in laptop) and viewpoint (easy vs. difficult view). In summary, although motion imaging provides an enhancement, it is not strong enough to allow leaving laptops in bags for security screening.
Can laptops be left inside passenger bags if motion imaging is used in X-ray security screening?
Mendes, Marcia; Schwaninger, Adrian; Michel, Stefan
2013-01-01
This paper describes a study where a new X-ray machine for security screening featuring motion imaging (i.e., 5 views of a bag are shown as an image sequence) was evaluated and compared to single view imaging available on conventional X-ray screening systems. More specifically, it was investigated whether with this new technology X-ray screening of passenger bags could be enhanced to such an extent that laptops could be left inside passenger bags, without causing a significant impairment in threat detection performance. An X-ray image interpretation test was created in four different versions, manipulating the factors packing condition (laptop and bag separate vs. laptop in bag) and display condition (single vs. motion imaging). There was a highly significant and large main effect of packing condition. When laptops and bags were screened separately, threat item detection was substantially higher. For display condition, a medium effect was observed. Detection could be slightly enhanced through the application of motion imaging. There was no interaction between display and packing condition, implying that the high negative effect of leaving laptops in passenger bags could not be fully compensated by motion imaging. Additional analyses were carried out to examine effects depending on different threat categories (guns, improvised explosive devices, knives, others), the placement of the threat items (in bag vs. in laptop) and viewpoint (easy vs. difficult view). In summary, although motion imaging provides an enhancement, it is not strong enough to allow leaving laptops in bags for security screening. PMID:24151457
Factors influencing participation in colorectal cancer screening programs in Spain.
Vanaclocha-Espi, Mercedes; Ibáñez, Josefa; Molina-Barceló, Ana; Pérez, Elena; Nolasco, Andreu; Font, Rebeca; Pérez-Riquelme, Francisco; de la Vega, Mariola; Arana-Arri, Eunate; Oceja, MªElena; Espinàs, Josep Alfons; Portillo, Isabel; Salas, Dolores
2017-12-01
To analyze the sociodemographic and organizational factors influencing participation in population-based colorectal cancer screening programs (CRCSP) in Spain, a retrospective study was conducted in a cohort of people invited to participate in the first 3 screening rounds of 6 CRCSP from 2000 to 2012. Mixed logistic regression models were used to analyze the relationship between sociodemographic and organizational factors, such as the type of fecal occult blood test (FOBT) used and the FOBT delivery type. The analysis was performed separately in groups (Initial screening-first invitation, Subsequent invitation for previous never-responders, Subsequent invitation-regular, Subsequent invitation-irregular intervals). The results showed that, in the Initial screening-first invitation group, participation was higher in women than in men in all age groups (OR 1.05 in persons aged 50-59years and OR 1.12 in those aged 60-69years). Participation was also higher when no action was required to receive the FOBT kit, independently of the type of screening (Initial screening-first invitation [OR 2.24], Subsequent invitation for previous never-responders [OR 2.14], Subsequent invitation-regular [OR 2.03], Subsequent invitation-irregular intervals [OR 9.38]) and when quantitative rather than qualitative immunological FOBT (FIT) was offered (Initial screening-first invitation [OR 0.70], Subsequent invitation for previous never-responders [OR 0.12], Subsequent invitation-regular [OR 0.20]) or guaiac testing (Initial screening-first invitation [OR 0.81], Subsequent invitation for previous never-responders [OR 0.88], Subsequent invitation-regular [OR 0.73]). In conclusion, the results of this study show that screening participation could be enhanced by inclusion of the FOBT kit with the screening invitation and the use of the quantitative FIT. Copyright © 2017 Elsevier Inc. All rights reserved.
Design and Analyses of High Aspect Ratio Nozzles for Distributed Propulsion Acoustic Measurements
NASA Technical Reports Server (NTRS)
Dippold, Vance F., III
2016-01-01
A series of three convergent, round-to-rectangular high aspect ratio (HAR) nozzles were designed for acoustic testing at the NASA Glenn Research Center Nozzle Acoustic Test Rig (NATR). The HAR nozzles had exit area aspect ratios of 8:1, 12:1, and 16:1. The nozzles were designed to mimic a distributed propulsion system array with a slot nozzle. The nozzle designs were screened using Reynolds-Averaged Navier-Stokes (RANS) simulations. In addition to meeting the geometric constraints required for testing in the NATR, the HAR nozzles were designed to be free of flow features that would produce unwanted noise (e.g., flow separations) and to have uniform flow at the nozzle exit. Multiple methods were used to generate HAR nozzle designs. The final HAR nozzle designs were generated in segments using a computer code that parameterized each segment. RANS screening simulations showed that intermediate nozzle designs suffered flow separation, a normal shockwave at the nozzle exit (caused by an aerodynamic throat produced by boundary layer growth), and non-uniform flow at the nozzle exit. The RANS simulations showed that the final HAR nozzle designs were free of flow separations, but were not entirely successful at producing a fully uniform flow at the nozzle exit. The final designs suffered a pair of counter-rotating vortices along the outboard walls of the nozzle. The 16:1 aspect ratio HAR nozzle had the least uniform flow at the exit plane; the 8:1 aspect ratio HAR nozzles had a fairly uniform flow at the nozzle exit plane.
Blinded Validation of Breath Biomarkers of Lung Cancer, a Potential Ancillary to Chest CT Screening
Phillips, Michael; Bauer, Thomas L.; Cataneo, Renee N.; Lebauer, Cassie; Mundada, Mayur; Pass, Harvey I.; Ramakrishna, Naren; Rom, William N.; Vallières, Eric
2015-01-01
Background Breath volatile organic compounds (VOCs) have been reported as biomarkers of lung cancer, but it is not known if biomarkers identified in one group can identify disease in a separate independent cohort. Also, it is not known if combining breath biomarkers with chest CT has the potential to improve the sensitivity and specificity of lung cancer screening. Methods Model-building phase (unblinded): Breath VOCs were analyzed with gas chromatography mass spectrometry in 82 asymptomatic smokers having screening chest CT, 84 symptomatic high-risk subjects with a tissue diagnosis, 100 without a tissue diagnosis, and 35 healthy subjects. Multiple Monte Carlo simulations identified breath VOC mass ions with greater than random diagnostic accuracy for lung cancer, and these were combined in a multivariate predictive algorithm. Model-testing phase (blinded validation): We analyzed breath VOCs in an independent cohort of similar subjects (n = 70, 51, 75 and 19 respectively). The algorithm predicted discriminant function (DF) values in blinded replicate breath VOC samples analyzed independently at two laboratories (A and B). Outcome modeling: We modeled the expected effects of combining breath biomarkers with chest CT on the sensitivity and specificity of lung cancer screening. Results Unblinded model-building phase. The algorithm identified lung cancer with sensitivity 74.0%, specificity 70.7% and C-statistic 0.78. Blinded model-testing phase: The algorithm identified lung cancer at Laboratory A with sensitivity 68.0%, specificity 68.4%, C-statistic 0.71; and at Laboratory B with sensitivity 70.1%, specificity 68.0%, C-statistic 0.70, with linear correlation between replicates (r = 0.88). In a projected outcome model, breath biomarkers increased the sensitivity, specificity, and positive and negative predictive values of chest CT for lung cancer when the tests were combined in series or parallel. Conclusions Breath VOC mass ion biomarkers identified lung cancer in a separate independent cohort, in a blinded replicated study. Combining breath biomarkers with chest CT could potentially improve the sensitivity and specificity of lung cancer screening. Trial Registration ClinicalTrials.gov NCT00639067 PMID:26698306
Mandelblatt, J; Traxler, M; Lakin, P; Kanetsky, P; Kao, R
1993-01-01
Factors associated with participation in breast and cervix cancer screening among elderly black women of low socioeconomic status were determined. Data from a baseline cross-sectional random survey were used together with data on whether screening was subsequently completed or refused. The subjects were a random sample of women attending an urban public hospital primary care clinic for routine medical care with a birth year of 1924 or earlier. Among the 271 women in the study group, 70% completed screening. Stated intent was the strongest predictor of participation; women who intended to have both mammography and Pap testing were 2.7 times more likely to participate than those who intended to have neither test (95% confidence interval 1.4, 4.9; P < 0.01), controlling for age, insurance status, and level of chronic illness. Women who had more than three chronic illnesses were twice as likely to participate than those with three or fewer illnesses (95% confidence interval 1.1, 3.4 P < 0.02), controlling for the remaining variables. Other variables, including age, history of a recent screening examination, attitudes, or knowledge, were not related to participation. Stated intent was the only variable that predicted compliance with both mammography and Pap smear completion in separate regression models for the individual tests. A high proportion of elderly, socioeconomically disadvantaged black women will participate in cancer screening when it is offered in a primary care setting. Further research on behavioral intentions should be conducted to refine interventions designed to enhance the use of early cancer detection among vulnerable population groups.
Electrophoretic sample insertion. [device for uniformly distributing samples in flow path
NASA Technical Reports Server (NTRS)
Mccreight, L. R. (Inventor)
1974-01-01
Two conductive screens located in the flow path of an electrophoresis sample separation apparatus are charged electrically. The sample is introduced between the screens, and the charge is sufficient to disperse and hold the samples across the screens. When the charge is terminated, the samples are uniformly distributed in the flow path. Additionally, a first separation by charged properties has been accomplished.
3-D viscous flow CFD analysis of the propeller effect on an advanced ducted propeller subsonic inlet
NASA Technical Reports Server (NTRS)
Iek, Chanthy; Boldman, Donald R.; Ibrahim, Mounir
1993-01-01
The time-marching Navier-Stokes code PARC3D was used to study the 3D viscous flow associated with an advanced ducted propeller subsonic inlet at take-off operating conditions. At a free stream Mach number of 0.2, experimental data for the inlet-with-propeller test model indicated that the airflow was attached on the cowl windward lip at an angle of attack of 25 deg became unstable at 29 deg, and separated at 30 deg. An experimental study with a similar inlet and without propeller (through-flow) indicated that flow separation occurred at an angle of attack a few degrees below the value observed when the inlet was tested with the propeller, indicating the propeller's favorable effect on inlet performance. In the present numerical study, flow blockage analogous to the propeller was modeled via a PARC3D computational boundary condition (BC), the 'screen BC', based on 1-1/2 dimension actuator disk theory. The application of the screen BC in this numerical study provided results similar to those of past experimental efforts in which either the blockage device or the propeller was used.
Smart material screening machines using smart materials and controls
NASA Astrophysics Data System (ADS)
Allaei, Daryoush; Corradi, Gary; Waigand, Al
2002-07-01
The objective of this product is to address the specific need for improvements in the efficiency and effectiveness in physical separation technologies in the screening areas. Currently, the mining industry uses approximately 33 billion kW-hr per year, costing 1.65 billion dollars at 0.05 cents per kW-hr, of electrical energy for physical separations. Even though screening and size separations are not the single most energy intensive process in the mining industry, they are often the major bottleneck in the whole process. Improvements to this area offer tremendous potential in both energy savings and production improvements. Additionally, the vibrating screens used in the mining processing plants are the most costly areas from maintenance and worker health and safety point of views. The goal of this product is to reduce energy use in the screening and total processing areas. This goal is accomplished by developing an innovative screening machine based on smart materials and smart actuators, namely smart screen that uses advanced sensory system to continuously monitor the screening process and make appropriate adjustments to improve production. The theory behind the development of Smart Screen technology is based on two key technologies, namely smart actuators and smart Energy Flow ControlT (EFCT) strategies, developed initially for military applications. Smart Screen technology controls the flow of vibration energy and confines it to the screen rather than shaking much of the mass that makes up the conventional vibratory screening machine. Consequently, Smart Screens eliminates and downsizes many of the structural components associated with conventional vibratory screening machines. As a result, the surface area of the screen increases for a given envelope. This increase in usable screening surface area extends the life of the screens, reduces required maintenance by reducing the frequency of screen change-outs and improves throughput or productivity.
Cost-Effectiveness of Screening Individuals With Cystic Fibrosis for Colorectal Cancer.
Gini, Andrea; Zauber, Ann G; Cenin, Dayna R; Omidvari, Amir-Houshang; Hempstead, Sarah E; Fink, Aliza K; Lowenfels, Albert B; Lansdorp-Vogelaar, Iris
2017-12-27
Individuals with cystic fibrosis are at increased risk of colorectal cancer (CRC) compared to the general population, and risk is higher among those who received an organ transplant. We performed a cost-effectiveness analysis to determine optimal CRC screening strategies for patients with cystic fibrosis. We adjusted the existing Microsimulation Screening Analysis-Colon microsimulation model to reflect increased CRC risk and lower life expectancy in patients with cystic fibrosis. Modeling was performed separately for individuals who never received an organ transplant and patients who had received an organ transplant. We modeled 76 colonoscopy screening strategies that varied the age range and screening interval. The optimal screening strategy was determined based on a willingness to pay threshold of $100,000 per life-year gained. Sensitivity and supplementary analyses were performed, including fecal immunochemical test (FIT) as an alternative test, earlier ages of transplantation, and increased rates of colonoscopy complications, to assess whether optimal screening strategies would change. Colonoscopy every 5 years, starting at age 40 years, was the optimal colonoscopy strategy for patients with cystic fibrosis who never received an organ transplant; this strategy prevented 79% of deaths from CRC. Among patients with cystic fibrosis who had received an organ transplant, optimal colonoscopy screening should start at an age of 30 or 35 years, depending on the patient's age at time of transplantation. Annual FIT screening was predicted to be cost-effective for patients with cystic fibrosis. However, the level of accuracy of the FIT in population is not clear. Using a Microsimulation Screening Analysis-Colon microsimulation model, we found screening of patients with cystic fibrosis for CRC to be cost-effective. Due to the higher risk in these patients for CRC, screening should start at an earlier age with a shorter screening interval. The findings of this study (especially those on FIT screening) may be limited by restricted evidence available for patients with cystic fibrosis. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Cost Effectiveness of Screening Individuals With Cystic Fibrosis for Colorectal Cancer.
Gini, Andrea; Zauber, Ann G; Cenin, Dayna R; Omidvari, Amir-Houshang; Hempstead, Sarah E; Fink, Aliza K; Lowenfels, Albert B; Lansdorp-Vogelaar, Iris
2018-02-01
Individuals with cystic fibrosis are at increased risk of colorectal cancer (CRC) compared with the general population, and risk is higher among those who received an organ transplant. We performed a cost-effectiveness analysis to determine optimal CRC screening strategies for patients with cystic fibrosis. We adjusted the existing Microsimulation Screening Analysis-Colon model to reflect increased CRC risk and lower life expectancy in patients with cystic fibrosis. Modeling was performed separately for individuals who never received an organ transplant and patients who had received an organ transplant. We modeled 76 colonoscopy screening strategies that varied the age range and screening interval. The optimal screening strategy was determined based on a willingness to pay threshold of $100,000 per life-year gained. Sensitivity and supplementary analyses were performed, including fecal immunochemical test (FIT) as an alternative test, earlier ages of transplantation, and increased rates of colonoscopy complications, to assess if optimal screening strategies would change. Colonoscopy every 5 years, starting at an age of 40 years, was the optimal colonoscopy strategy for patients with cystic fibrosis who never received an organ transplant; this strategy prevented 79% of deaths from CRC. Among patients with cystic fibrosis who had received an organ transplant, optimal colonoscopy screening should start at an age of 30 or 35 years, depending on the patient's age at time of transplantation. Annual FIT screening was predicted to be cost-effective for patients with cystic fibrosis. However, the level of accuracy of the FIT in this population is not clear. Using a Microsimulation Screening Analysis-Colon model, we found screening of patients with cystic fibrosis for CRC to be cost effective. Because of the higher risk of CRC in these patients, screening should start at an earlier age with a shorter screening interval. The findings of this study (especially those on FIT screening) may be limited by restricted evidence available for patients with cystic fibrosis. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Sanyal, Parikshit; Ganguli, Prosenjit; Barui, Sanghita; Deb, Prabal
2018-01-01
The Pap stained cervical smear is a screening tool for cervical cancer. Commercial systems are used for automated screening of liquid based cervical smears. However, there is no image analysis software used for conventional cervical smears. The aim of this study was to develop and test the diagnostic accuracy of a software for analysis of conventional smears. The software was developed using Python programming language and open source libraries. It was standardized with images from Bethesda Interobserver Reproducibility Project. One hundred and thirty images from smears which were reported Negative for Intraepithelial Lesion or Malignancy (NILM), and 45 images where some abnormality has been reported, were collected from the archives of the hospital. The software was then tested on the images. The software was able to segregate images based on overall nuclear: cytoplasmic ratio, coefficient of variation (CV) in nuclear size, nuclear membrane irregularity, and clustering. 68.88% of abnormal images were flagged by the software, as well as 19.23% of NILM images. The major difficulties faced were segmentation of overlapping cell clusters and separation of neutrophils. The software shows potential as a screening tool for conventional cervical smears; however, further refinement in technique is required.
Hur, Chin; Choi, Sung Eun; Kong, Chung Yin; Wang, Gui-Qi; Xu, Hong; Polydorides, Alexandros D; Xue, Li-Yan; Perzan, Katherine E; Tramontano, Angela C; Richards-Kortum, Rebecca R; Anandasabapathy, Sharmila
2015-05-14
To study the cost-effectiveness of high-resolution microendoscopy (HRME) in an esophageal squamous cell carcinoma (ESCC) screening program in China. A decision analytic Markov model of ESCC was developed. Separate model analyses were conducted for cohorts consisting of an average-risk population or a high-risk population in China. Hypothetical 50-year-old individuals were followed until age 80 or death. We compared three different strategies for both cohorts: (1) no screening; (2) standard endoscopic screening with Lugol's iodine staining; and (3) endoscopic screening with Lugol's iodine staining and an HRME. Model parameters were estimated from the literature as well as from GLOBOCAN, the Cancer Incidence and Mortality Worldwide cancer database. Health states in the model included non-neoplasia, mild dysplasia, moderate dysplasia, high-grade dysplasia, intramucosal carcinoma, operable cancer, inoperable cancer, and death. Separate ESCC incidence transition rates were generated for the average-risk and high-risk populations. Costs in Chinese currency were converted to international dollars (I$) and were adjusted to 2012 dollars using the Consumer Price Index. The main outcome measurements for this study were quality-adjusted life years (QALYs) and incremental cost-effectiveness ratio (ICER). For the average-risk population, the HRME screening strategy produced 0.043 more QALYs than the no screening strategy at an additional cost of I$646, resulting in an ICER of I$11808 per QALY gained. Standard endoscopic screening was weakly dominated. Among the high-risk population, when the HRME screening strategy was compared with the standard screening strategy, the ICER was I$8173 per QALY. For both the high-risk and average-risk screening populations, the HRME screening strategy appeared to be the most cost-effective strategy, producing ICERs below the willingness-to-pay threshold, I$23500 per QALY. One-way sensitivity analysis showed that, for the average-risk population, higher specificity of Lugol's iodine (> 40%) and lower specificity of HRME (< 70%) could make Lugol's iodine screening cost-effective. For the high-risk population, the results of the model were not substantially affected by varying the follow-up rate after Lugol's iodine screening, Lugol's iodine test characteristics (sensitivity and specificity), or HRME specificity. The incorporation of HRME into an ESCC screening program could be cost-effective in China. Larger studies of HRME performance are needed to confirm these findings.
[Hearing screening at nursery schools: results of an evaluation study].
Weichbold, Viktor; Rohrer, Monika; Winkler, Cornelia; Welzl-Müller, Kunigunde
2004-07-31
This study aimed to evaluate the hearing screening of pre-school children at nursery schools in Tyrol, Austria. 47 nursery schools with a total of 2199 enrolled children participated in the study. At the screening, the children were presented a series of tones at frequencies 0.5 kHz (25dB), 1 kHz, 2 kHz, 3 kHz, and 4 kHz (20 dB each) from portable audiometers. The tones were presented over headphones for each ear separately and at irregular intervals. Failure to respond to any of the frequencies was considered failure of the screening. Parents were then advised in written form to have the child examined by an ENT-specialist. 1832 individuals were screened (coverage: 83% of nursery school children; corresponding to at least 63% of all Tyrolean children aged 3 to 5 years). Of these, 390 failed the test (referral rate: 21% of all screened). Examination through an ENT-specialist occurred with 217 children, and this confirmed the positive test in 139 children (hit rate: 64%). In most cases, a temporary conductive hearing loss due to external or middle ear problems (glue ear, tube dysfunction, cerumen, otitis media) was diagnosed. A sensorineural hearing loss was found in 4 children (in 3 of them bilateral). The need for therapy was recognized in 81 children (4% of all screened). Pre-school hearing screening identifies children with ear and hearing problems that need therapeutical intervention. Although the hearing problems are mostly of a temporary nature, some may require monitoring over some period. Also some children with permanent sensorineural hearing loss may be detected through this measure. Hearing screening is an efficient means of assessing ear and hearing problems in pre-school children. However, the follow-up rate needs to be improved for optimizing the efficacy.
Baxter, Nielson T; Koumpouras, Charles C; Rogers, Mary A M; Ruffin, Mack T; Schloss, Patrick D
2016-11-14
There is a significant demand for colorectal cancer (CRC) screening methods that are noninvasive, inexpensive, and capable of accurately detecting early stage tumors. It has been shown that models based on the gut microbiota can complement the fecal occult blood test and fecal immunochemical test (FIT). However, a barrier to microbiota-based screening is the need to collect and store a patient's stool sample. Using stool samples collected from 404 patients, we tested whether the residual buffer containing resuspended feces in FIT cartridges could be used in place of intact stool samples. We found that the bacterial DNA isolated from FIT cartridges largely recapitulated the community structure and membership of patients' stool microbiota and that the abundance of bacteria associated with CRC were conserved. We also found that models for detecting CRC that were generated using bacterial abundances from FIT cartridges were equally predictive as models generated using bacterial abundances from stool. These findings demonstrate the potential for using residual buffer from FIT cartridges in place of stool for microbiota-based screening for CRC. This may reduce the need to collect and process separate stool samples and may facilitate combining FIT and microbiota-based biomarkers into a single test. Additionally, FIT cartridges could constitute a novel data source for studying the role of the microbiome in cancer and other diseases.
Marshall, Nicole E; Fraley, Gwen; Feist, Cori; Burns, Michael J; Pereira, Leonardo
2012-08-01
To determine the prevalence of abnormal karyotype results in women undergoing chorionic villus sampling (CVS) for abnormal first trimester screening compared to CVS for historical indications (advanced maternal age (AMA) or prior aneuploidy). Retrospective cohort of all patients undergoing CVS at Oregon Health & Science University from January 2006 to June 2010. Patients were separated based on CVS indication: (1) positive ultrasound (U/S) or serum screening; or (2) AMA or prior aneuploidy with normal or no screening. Prevalence of abnormal karyotype results were compared between groups. Fetal karyotyping was successful in 500 of 506 CVS procedures performed. 203 CVS were performed for positive screening with 69 abnormal karyotypes (34.0%). 264 CVS were performed for historical indications with 11 abnormal karyotypes (4.2%). This difference was statistically significant (χ(2) 71.9, p < 0.001; OR 11.8 [95% CI 5.8, 24.6]). There were two age-related aneuplodies in AMA women without positive screening. 42 out of 44 AMA women diagnosed with aneuploidy (95.5%) had abnormal U/S and/or serum screening (35 U/S, 4 serum, 3 U/S and serum). Combined ultrasound and serum screening should be recommended to all women, including AMA women, prior to undergoing invasive testing to improve risk-based counseling and minimize morbidity.
New test techniques to evaluate near field effects for supersonic store carriage and separation
NASA Technical Reports Server (NTRS)
Sawyer, Wallace C.; Stallings, Robert L., Jr.; Wilcox, Floyd J., Jr.; Blair, A. B., Jr.; Monta, William J.; Plentovich, Elizabeth B.
1989-01-01
Store separation and store carriage drag studies were conducted. A primary purpose is to develop new experimental methods to evaluate near field effects of store separation and levels of store carriage drag associated with a variety of carriage techniques for different store shapes and arrangements. Flow field measurements consisting of surface pressure distributions and vapor screen photographs are used to analyze the variations of the store separation characteristics with cavity geometry. Store carriage drag measurements representative of tangent, semi-submerged, and internal carriage installations are presented and discussed. Results are included from both fully metric models and models with only metric segments (metric pallets) and the relative merits of the two are discussed. Carriage drag measurements for store installations on an aircraft parent body are compared both with prediction methods and with installations on a generic parent body.
Jawin, Vida; Ang, Hak-Lee; Omar, Asma; Thong, Meow-Keong
2015-01-01
Studies on pulse oximetry screening for neonatal sepsis and respiratory disease in a middle-income country are lacking. Newborn screening for critical congenital heart disease (CCHD) using pulse oximetry is an effective and life-saving strategy in developed countries. While most studies have reported false-positive results during CCHD screening, they have not elaborated on the detected disease types. We studied the effectiveness and outcomes of pulse oximetry newborn screening for non-cardiac hypoxemic diseases such as neonatal sepsis, respiratory diseases, and CCHD in a middle-income country. In a pilot study performed at the University Malaya Medical Centre (UMMC), Malaysia, all apparently healthy term newborns, delivered at UMMC were screened pre-discharge using pulse oximetry. Echocardiography was performed for newborns that had positive screening results on two separate occasions, 1-h apart. Newborns with normal echocardiograms were evaluated and treated for other non-cardiac diseases. Fifteen of 5247 term newborns had positive screening results. The median age at screening was 20 h. Thirteen newborns (0.24%) had significant non-cardiac diseases: sepsis (n = 2) and respiratory diseases (n = 11) that required hospitalization and treatment. The remaining two newborns with normal antenatal ultrasonograms had positive screening test and confirmed to have CCHD. Another 18 newborns with negative screening test were later admitted for treatment of sepsis (n = 16) and penumonia (n = 2). All newborns were treated and alive at the end of the study. The sensitivity and specificity of pulse oximetry screening for non-cardiac diseases were 42% and 99.9% respectively, and 100% and 99.7% for CCHD, respectively. Routine pulse oximetry screening test was effective in identifying newborns with CCHD and other hypoxemia illnesses, which may led to potential life-threatening condition. This study showed that the expanded use of pulse oximetry has immediate implications for low- and middle-income countries contemplating strategies to reduce neonatal mortality and morbidity. ASD, atrial septal defect; CCHD, critical congenital heart disease; CRP, C-reactive protein; CXR, chest radiographs; NDI, neurodevelopment impairment; PPHN, persistent pulmonary hypertension of the newborn; PDA, patent ductus arteriosus; PFO, patent foramen ovale; TGA, transposition of great artery; TTN, transient tachypnoea of the newborn; VSD, ventricular septal defect.
Diel, F; Neidhart, B; Oprée, W
1981-01-01
The direct action of sensitizing occupational chemicals (formaldehyde, phenol, phenylhydrazine, p-aminophenol) on rat mast cells was investigated by determination of histamine using HPLC separation and fluorimetric detection. It turned out that dispensed mast cells from immunized and non-immunized Wistar-rats are more sensitive than small-cut lung tissue slices. Passive cutaneous anaphylaxis was negative after a fortnight sensitizing experiment with the here described occupational chemicals. Short-time tests with rat mast cells reflect anaphylactoid response and are suitable for the screening of sensitizing chemicals.
Underscreening in concentrated electrolytes.
Lee, Alpha A; Perez-Martinez, Carla S; Smith, Alexander M; Perkin, Susan
2017-07-01
Screening of a surface charge by an electrolyte and the resulting interaction energy between charged objects is of fundamental importance in scenarios from bio-molecular interactions to energy storage. The conventional wisdom is that the interaction energy decays exponentially with object separation and the decay length is a decreasing function of ion concentration; the interaction is thus negligible in a concentrated electrolyte. Contrary to this conventional wisdom, we have shown by surface force measurements that the decay length is an increasing function of ion concentration and Bjerrum length for concentrated electrolytes. In this paper we report surface force measurements to test directly the scaling of the screening length with Bjerrum length. Furthermore, we identify a relationship between the concentration dependence of this screening length and empirical measurements of activity coefficient and differential capacitance. The dependence of the screening length on the ion concentration and the Bjerrum length can be explained by a simple scaling conjecture based on the physical intuition that solvent molecules, rather than ions, are charge carriers in a concentrated electrolyte.
Centrifugal Sieve for Gravity-Level-Independent Size Segregation of Granular Materials
NASA Technical Reports Server (NTRS)
Walton, Otis R.; Dreyer, Christopher; Riedel, Edward
2013-01-01
Conventional size segregation or screening in batch mode, using stacked vibrated screens, is often a time-consuming process. Utilization of centrifugal force instead of gravity as the primary body force can significantly shorten the time to segregate feedstock into a set of different-sized fractions. Likewise, under reduced gravity or microgravity, a centrifugal sieve system would function as well as it does terrestrially. When vibratory and mechanical blade sieving screens designed for terrestrial conditions were tested under lunar gravity conditions, they did not function well. The centrifugal sieving design of this technology overcomes the issues that prevented sieves designed for terrestrial conditions from functioning under reduced gravity. These sieves feature a rotating outer (cylindrical or conical) screen wall, rotating fast enough for the centrifugal forces near the wall to hold granular material against the rotating screen. Conventional centrifugal sieves have a stationary screen and rapidly rotating blades that shear the granular solid near the stationary screen, and effect the sieving process assisted by the airflow inside the unit. The centrifugal sieves of this new design may (or may not) have an inner blade or blades, moving relative to the rotating wall screen. Some continuous flow embodiments would have no inner auger or blades, but achieve axial motion through vibration. In all cases, the shearing action is gentler than conventional centrifugal sieves, which have very high velocity differences between the stationary outer screen and the rapidly rotating blades. The new design does not depend on airflow in the sieving unit, so it will function just as well in vacuum as in air. One advantage of the innovation for batch sieving is that a batch-mode centrifugal sieve may accomplish the same sieving operation in much less time than a conventional stacked set of vibrated screens (which utilize gravity as the primary driving force for size separation). In continuous mode, the centrifugal sieves can provide steady streams of fine and coarse material separated from a mixed feedstock flow stream. The centrifugal sieves can be scaled to any desired size and/or mass flow rate. Thus, they could be made in sizes suitable for small robotic exploratory missions, or for semi-permanent processing of regolith for extraction of volatiles of minerals. An advantage of the continuous-mode system is that it can be made with absolutely no gravity flow components for feeding material into, or for extracting the separated size streams from, the centrifugal sieve. Thus, the system is capable of functioning in a true microgravity environment. Another advantage of the continuous-mode system is that some embodiments of the innovation have no internal blades or vanes, and thus, can be designed to handle a very wide range of feedstock sizes, including occasional very large oversized pieces, without jamming or seizing up.
2016-05-01
M72 LAW 66mm (Light Anti -Tank Weapon), and RPG (Rocket Propelled Grenades) with varying munitions...one-time publications. Report any book, monograph, dissertation , abstract, or the like published as or in a separate publication, rather than a...year; type of publication (e.g., book, thesis or dissertation ); status of publication (published; accepted, awaiting publication; submitted, under
Flow method and apparatus for screening chemicals using micro x-ray fluorescence
Warner, Benjamin P [Los Alamos, NM; Havrilla, George J [Los Alamos, NM; Miller, Thomasin C [Bartlesville, OK; Lewis, Cris [Los Alamos, NM; Mahan, Cynthia A [Los Alamos, NM; Wells, Cyndi A [Los Alamos, NM
2009-04-14
Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow-separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.
Flow method and apparatus for screening chemicals using micro x-ray fluorescence
Warner, Benjamin P [Los Alamos, NM; Havrilla, George J [Los Alamos, NM; Miller, Thomasin C [Bartlesville, OK; Lewis, Cris [Los Alamos, NM; Mahan, Cynthia A [Los Alamos, NM; Wells, Cyndi A [Los Alamos, NM
2011-04-26
Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.
Jaki, Thomas; Allacher, Peter; Horling, Frank
2016-09-05
Detecting and characterizing of anti-drug antibodies (ADA) against a protein therapeutic are crucially important to monitor the unwanted immune response. Usually a multi-tiered approach that initially rapidly screens for positive samples that are subsequently confirmed in a separate assay is employed for testing of patient samples for ADA activity. In this manuscript we evaluate the ability of different methods used to classify subject with screening and competition based confirmatory assays. We find that for the overall performance of the multi-stage process the method used for confirmation is most important where a t-test is best when differences are moderate to large. Moreover we find that, when differences between positive and negative samples are not sufficiently large, using a competition based confirmation step does yield poor classification of positive samples. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Stanley, A. G.; Price, W. E.
1976-01-01
An extensive investigation of irradiate-anneal (IRAN) screening against total dose radiation effects was carried out as part of a program to harden the Mariner Jupiter/Saturn 1977 (MJS'77) spacecraft to survive the Jupiter radiation belts. The method consists of irradiating semiconductor devices with Cobalt-60 to a suitable total dose under representative bias conditions and of separating the parts in the undesired tail of the distribution from the bulk of the parts by means of a predetermined acceptance limit. The acceptable devices are then restored close to their preirradiation condition by annealing them at an elevated temperature. IRAN was used when lot screen methods were impracticable due to lack of time, and when members of a lot showed a diversity of radiation response. The feasibility of the technique was determined by testing of a number of types of linear bipolar integrated circuits, analog switches, n-channel JFETS and bipolar transistors. Based on the results of these experiments a number of device types were selected for IRAN of flight parts in the MJS'77 spacecraft systems. The part types, screening doses, acceptance criteria, number of parts tested and rejected as well as the program steps are detailed.
Tölgyesi, Ádám; Barta, Enikő; Simon, Andrea; McDonald, Thomas J; Sharma, Virender K
2017-10-25
Veterinary drugs containing synthetic anabolic steroid and nitroimidazole active agents are not allowed for their applications in livestock of the European Union (EU). This paper presents analyses of twelve selected steroids and six nitroimidazole antibiotics at low levels (1.56μg/L-4.95μg/L and 0.17μg/kg-2.14μg/kg, respectively) in body fluids and egg incurred samples. Analyses involved clean-up procedures, high performance liquid chromatography (HPLC) separation, and tandem mass spectrometric screening and confirmatory methods. Target steroids and nitroimidazoles in samples were cleaned by two independent supported liquid extraction and solid phase extraction procedures. Separation of the selected compounds was conducted on Kinetex XB C-18 HPLC column using gradient elution. The screening methods utilised supported liquid extraction that enabled fast and cost effective clean-up. The confirmatory methods were improved by extending the number of matrices and compounds, and by introducing an isotope dilution mass spectrometry for nitroimidazoles. The new methods were validated according to the recommendation of the European Union Reference Laboratories and the performance characteristics evaluated met fully the criteria. The methods were applied to incurred samples in the proficiency tests. The obtained results of Z-scores demonstrated the applicability of developed protocols of the methods to real samples. The confirmatory methods were applied to the national monitoring program and natural contamination of prednisolone could be detected in urine at low concentration in few samples. Copyright © 2017 Elsevier B.V. All rights reserved.
In vivo screening of candidate pretreatment compounds against cyanide using mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiser, R.C.; Olson, C.T.; Menton, R.G.
1993-05-13
An in vivo screening procedure was established at Battelle's Medical Research and Evaluation Facility (MREF) to evaluate the efficacy of candidate pretreatment compounds in mice challenged with the blood agent, sodium cyanide (NaCN). Male albino mice of ICR outbred stock weighing between 22.5 and 27.5 g are challenged by intramuscular (i.m.) injection, at a volume of 0.5 mL/kg, of a dose of NaCN twice the LD50 of untreated mice as determined on that day of testing. Candidate drugs are tested at fractions of their LD50 or their limit of solubility in the most optimum vehicle and given intraperitoneally (i.p.) tomore » separate groups of mice at either 60 or 15 min prior to NaCN challenge. Sodium thiosulfate (1000 mg/kg)/sodium nitrite (100 mg/kg) controls are injected i.p. only at 60 min prior to challenge. A test compound is deemed effective if, at any of three concentrations tested, or at either pretreatment time, it is statistically more efficacious in preventing lethality than is a negative control substance (candidate compound vehicle).« less
Sun, Meng; Ma, Wei-na; Guo, Ying; Hu, Zhi-gang; He, Lang-chong
2013-07-01
The epidermal growth factor receptors (EGFRs) are significant targets for screening active compounds. In this work, an analytical method was established for rapid screening, separation, and identification of EGFRs antagonists from Curcuma longa. Human embryonic kidney 293 cells with a steadily high expression of EGFRs were used to prepare the cell membrane stationary phase in a cell membrane chromatography model for screening active compounds. Separation and identification of the retention chromatographic peaks was achieved by HPLC-MS. The active sites, docking extents and inhibitory effects of the active compounds were also demonstrated. The screening result found that ar-turmerone, curcumin, demethoxycurcumin, and bisdemethoxycurcumin from Curcuma longa could be active components in a similar manner to gefitinib. Biological trials showed that all of four compounds can inhibit EGFRs protein secretion and cell growth in a dose-dependent manner, and downregulate the phosphorylation of EGFRs. This analytical method demonstrated fast and effective characteristics for screening, separation and identification of the active compounds from a complex system and should be useful for drug discovery with natural medicinal herbs. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy
2017-06-01
Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context. A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur. Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters. The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls. © 2017 John Wiley & Sons, Ltd.
Vinson, Daniel C.; Turner, Barbara J.; MSED; Manning, Brian K.; Galliher, James M.
2013-01-01
PURPOSE In clinical practice, detection of alcohol problems often relies on clinician suspicion instead of using a screening instrument. We assessed the sensitivity, specificity, and predictive values of clinician suspicion compared with screening-detected alcohol problems in patients. METHODS We undertook a cross-sectional study of 94 primary care clinicians’ office visits. Brief questionnaires were completed separately after a visit by both clinicians and eligible patients. The patient’s anonymous exit questionnaire screened for hazardous drinking based on the Alcohol Use Disorders Identification Test-Consumption (AUDIT-C) and for harmful drinking (alcohol abuse or dependence) based on 2 questions from the Diagnostic and Statistical Manual of Mental Disorders. After the visit, clinicians responded to the question, “Does this patient have problems with alcohol?” with answer options including “yes, hazardous drinking” and “yes, alcohol abuse or dependence.” Analyses assessed the associations between patients’ responses to screening questions and clinician’s suspicions. RESULTS Of 2,518 patients with an office visit, 2,173 were eligible, and 1,699 (78%) completed the exit questionnaire. One hundred seventy-one (10.1%) patients had a positive screening test for hazardous drinking (an AUDIT-C score of 5 or greater) and 64 (3.8%) for harmful drinking. Clinicians suspected alcohol problems in 81 patients (hazardous drinking in 37, harmful drinking in 40, and both in 4). The sensitivity of clinician suspicion of either hazardous or harmful drinking was 27% and the specificity was 98%. Positive and negative predictive values were 62% and 92%, respectively. CONCLUSION Clinician suspicion of alcohol problems had poor sensitivity but high specificity for identifying patients who had a positive screening test for alcohol problems. These data support the routine use of a screening tool to supplement clinicians’ suspicions, which already provide reasonable positive predictive value. PMID:23319506
Gas separation and bubble behavior at a woven screen
NASA Astrophysics Data System (ADS)
Conrath, Michael; Dreyer, Michael E.
Gas-liquid two phase flows are widespread and in many applications the separation of both phases is necessary. Chemical reactors, water treatment devices or gas-free delivery of liquids like propellant are only some of them. We study the performance of a woven metal screen in respect to its phase separation behavior under static and dynamic conditions. Beside hydraulic screen resistance and static bubble point, our study also comprises the bubble detachment from the screen upon gas breakthrough. Since a woven screen is essentially an array of identical pores, analogies to bubble detachment from a needle can be established. While the bubble point poses an upper limit for pressurized gas at a wetted screen to preclude gas breakthrough, the necessary pressure for growing bubbles to detach from the screen pores a lower limit when breakthrough is already in progress. Based on that inside, the dynamic bubble point effects were constituted that relate to a trapped bubble at such a screen in liquid flow. A trapped is caused to break through the screen by the flow-induced pressure drop across it. Our model includes axially symmetric bubble shapes, degree of coverage of the screen and bubble pressurization due to hydraulic losses in the rest of the circuit. We have built an experiment that consists of a Dutch Twilled woven screen made of stainless steel in a vertical acrylic glass tube. The liquid is silicon oil SF0.65. The screen is suspended perpendicular to the liquid flow which is forced through it at variable flow rate. Controlled injection of air from a needle allows us to examine the ability of the screen to separate gas and liquid along the former mentioned effects. We present experimental data on static bubble point and detachment pressure for breakthrough at different gas supply rates that suggest a useful criterion for reliable static bubble point measurements. Results for the dynamic bubble point are presented that include i) screen pressure drop for different trapped bubble volumes, liquid flow rates and flow-induced compression, ii) typical breakthrough of a trapped bubble at rising liquid flow rate and iii) steady gas supply in steady liquid flow. It shows that our model can explain the experimental observations. One of the interesting findings for the dynamic bubble point is that hydraulic losses in the rest of the circuit will shift the breakthrough of gas to higher liquid flow rates.
Macdonald, Isabel K.; Murray, Andrea; Healey, Graham F.; Parsy-Kowalska, Celine B.; Allen, Jared; McElveen, Jane; Robertson, Chris; Sewell, Herbert F.; Chapman, Caroline J.; Robertson, John F. R.
2012-01-01
Background The National Lung Screening Trial showed that CT screening for lung cancer led to a 20% reduction in mortality. However, CT screening has a number of disadvantages including low specificity. A validated autoantibody assay is available commercially (EarlyCDT®-Lung) to aid in the early detection of lung cancer and risk stratification in patients with pulmonary nodules detected by CT. Recent advances in high throughput (HTP) cloning and expression methods have been developed into a discovery pipeline to identify biomarkers that detect autoantibodies. The aim of this study was to demonstrate the successful clinical application of this strategy to add to the EarlyCDT-Lung panel in order to improve its sensitivity and specificity (and hence positive predictive value, (PPV)). Methods and Findings Serum from two matched independent cohorts of lung cancer patients were used (n = 100 and n = 165). Sixty nine proteins were initially screened on an abridged HTP version of the autoantibody ELISA using protein prepared on small scale by a HTP expression and purification screen. Promising leads were produced in shake flask culture and tested on the full assay. These results were analyzed in combination with those from the EarlyCDT-Lung panel in order to provide a set of re-optimized cut-offs. Five proteins that still displayed cancer/normal differentiation were tested for reproducibility and validation on a second batch of protein and a separate patient cohort. Addition of these proteins resulted in an improvement in the sensitivity and specificity of the test from 38% and 86% to 49% and 93% respectively (PPV improvement from 1 in 16 to 1 in 7). Conclusion This is a practical example of the value of investing resources to develop a HTP technology. Such technology may lead to improvement in the clinical utility of the EarlyCDT-Lung test, and so further aid the early detection of lung cancer. PMID:23272083
The design of disengaging mechanism of radix pseudostellariae and soil
NASA Astrophysics Data System (ADS)
Xiao, Shungen; Song, Mengmeng; Chen, Chanwei
2017-12-01
With the continuous development of the scale of the cultivation of the radix pseudostellariae, the traditional separation mode cannot adapt to the mass production of the crown prince, and the existing manual separation mode is of great labor intensity and low degree of mechanization. Therefore, it is necessary to design a disengaging mechanism of radix pseudostellariae and soil on the basis of the design principle of modern agricultural machinery. According to the physical characteristics and growing environment of radix pseudostellariae, a drum-type separating component is presented, and the drum screen separating mechanism and vibration mechanism of the disengaging mechanism are designed. In this paper, the movement rule and time of the mixture of radix pseudostellariae and soil are determined in the drum screen. Rotation speed of the drum screen is calculated, and the operation rules of the eccentric wheel in the vibration mechanism are summarized.
The inter and intra rater reliability of the Netball Movement Screening Tool.
Reid, Duncan A; Vanweerd, Rebecca J; Larmer, Peter J; Kingstone, Rachel
2015-05-01
To establish the inter- and intra-rater reliability of the Netball Movement Screening Tool, for screening adolescent female netball players. Inter- and intra-rater reliability study. Forty secondary school netball players were recruited to take part in the study. Twenty subjects were screened simultaneously and independently by two raters to ascertain inter-rater agreement. Twenty subjects were scored by rater one on two occasions, separated by a week, to ascertain intra-rater agreement. Inter and intra-rater agreement was assessed utilising the two-way mixed inter class correlation coefficient and weighted kappa statistics. No significant demographic differences were found between the inter and intra-rater groups of subjects. Inter class correlation coefficients' demonstrated excellent inter-rater (two-way mixed inter class correlation coefficients 0.84, standard error of measurement 0.25) and intra-rater (two-way mixed inter class correlation coefficients 0.96, standard error of measurement 0.13) reliability for the overall Netball Movement Screening Tool score and substantial-excellent (two-way mixed inter class correlation coefficients 1.0-0.65) inter-rater and substantial-excellent intra-rater (two-way mixed inter class correlation coefficients 0.96-0.79) reliability for the component scores of the Netball Movement Screening Tool. Kappa statistic showed substantial to poor inter-rater (k=0.75-0.32) and intra-rater (k=0.77-0.27) agreement for individual tests of the NMST. The Netball Movement Screening Tool may be a reliable screening tool for adolescent netball players; however the individual test scores have low reliability. The screening tool can be administered reliably by raters with similar levels of training in the tool but variable clinical experience. On-going research needs to be undertaken to ascertain whether the Netball Movement Screening Tool is a valid tool in ascertaining increased injury risk for netball players. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Centrifugal Size-Separation Sieve for Granular Materials
NASA Technical Reports Server (NTRS)
Walton, Otis (Inventor); Dreyer, Christopher (Inventor); Riedel, Edward (Inventor)
2015-01-01
A centrifugal sieve and method utilizes centrifugal force in rapidly-rotated cylindrical or conical screens as the primary body force contributing to size segregation. Within the centrifugal acceleration field, vibration and/or shearing flows are induced to facilitate size segregation and eventual separation of the fines from the coarse material. Inside a rotating cylindrical or conical screen, a separately-rotated screw auger blade can be used to transport material along the rotating cylinder or conical wall and to induce shearing in the material.
Mangine, Cara; Kukk, Aigi; Noormets, Helen; Jänes, Jaak; Rüütel, Kristi
2018-03-01
Men who have sex with men (MSM) face negative health outcomes such as sexually transmitted infections (STIs) at disproportionate rates. Nonetheless, infections may be underestimated due to limited uptake in testing. To increase testing, screening interventions have been utilized in the past; however, some have resulted in limitations such as poor recruitment. To increase recruitment for screening of MSM in Estonia, two different recruitment strategies were examined. Recruitment was separated into two promotional periods: passive and active. Passive consisted of banners on gay-related sites, while active also placed banners on websites to the general public such as Facebook linked to specific thematic pages and users self-identifying as men. More men were recruited during the active period of five weeks (n = 134) than the passive period of 46 weeks (n = 126). Active promotion was so successful in that the number of home sampling kit orders far exceeded what was projected, forcing promotion to the general public to be closed after 13 days. Recruiting MSM through a combination of general public and gay-related websites and applications has the ability to quickly recruit for testing interventions. This method can recruit a large number in a short amount of time; therefore, a budget must be planned accordingly to support testing for all that participate.
Optimization of a hydrodynamic separator using a multiscale computational fluid dynamics approach.
Schmitt, Vivien; Dufresne, Matthieu; Vazquez, Jose; Fischer, Martin; Morin, Antoine
2013-01-01
This article deals with the optimization of a hydrodynamic separator working on the tangential separation mechanism along a screen. The aim of this study is to optimize the shape of the device to avoid clogging. A multiscale approach is used. This methodology combines measurements and computational fluid dynamics (CFD). A local model enables us to observe the different phenomena occurring at the orifice scale, which shows the potential of expanded metal screens. A global model is used to simulate the flow within the device using a conceptual model of the screen (porous wall). After validation against the experimental measurements, the global model was used to investigate the influence of deflectors and disk plates in the structure.
Diagnostic value of screening tests in subgroups of women with recurrent pregnancy loss.
Guzel, Ali Irfan; Erkılınç, Selçuk; Özer, Irfan; Celik, Yusuf; Yılmaz, Nafiye; Doğanay, Melike
2015-03-01
To evaluate the diagnostic value of screening laboratory tests in women who had recurrent pregnancy loss (RPL). A total of 252 women with RPL managed in our tertiary referral research and education hospital were included in the study. Risk factors recorded involved age, gravidity, parity, number of prior live births, number of pregnancy losses, and thrombophlia tests. The cases were divided into three different groups and each group was analyzed separately. There was no statistically significant difference between the first and second groups in terms of clinical and laboratory parameters (p > 0.05). In the third group, there was a statistically significant difference among cases in terms of parity, gravidity, number of pregnancy losses, serum AT III levels, APCR, and age of the women. According to the logistic regression model, odds ratios (95% CI) were 6.116 (3.797-9.852), 5.665 (2.657-12.079), 4.763 (3.099-7.321), 4.729 (3.080-7.260), 2.820 (1.836-4.333), and 1.911 (1.232-2.965), respectively. We do not recommend the screening of all women with RPL, but in women with high parity and those who had prior live birth pregnancies, increased AT III, and APCR may be diagnostic markers for subsequent pregnancy loss.
NASA Astrophysics Data System (ADS)
Geiger, Benjamin; Hawkins, Samuel; Hall, Lawrence O.; Goldgof, Dmitry B.; Balagurunathan, Yoganand; Gatenby, Robert A.; Gillies, Robert J.
2016-03-01
Pulmonary nodules are effectively diagnosed in CT scans, but determining their malignancy has been a challenge. The rate of change of the volume of a pulmonary nodule is known to be a prognostic factor for cancer development. In this study, we propose that other changes in imaging characteristics are similarly informative. We examined the combination of image features across multiple CT scans, taken from the National Lung Screening Trial, with individual scans of the same patient separated by approximately one year. By subtracting the values of existing features in multiple scans for the same patient, we were able to improve the ability of existing classification algorithms to determine whether a nodule will become malignant. We trained each classifier on 83 nodules determined to be malignant by biopsy and 172 nodules determined to be benign by their clinical stability through two years of no change; classifiers were tested on 77 malignant and 144 benign nodules, using a set of features that in a test-retest experiment were shown to be stable. An accuracy of 83.71% and AUC of 0.814 were achieved with the Random Forests classifier on a subset of features determined to be stable via test-retest reproducibility analysis, further reduced with the Correlation-based Feature Selection algorithm.
Smart Screening System (S3) In Taconite Processing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daryoush Allaei; Ryan Wartman; David Tarnowski
2006-03-01
The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supportingmore » structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key components include smart motor and associated electronics, resonators, and supporting structural elements. It is shown that the smart motors have an acceptable life and performance. Resonator (or motion amplifier) designs are selected based on the final system requirement and vibration characteristics. All the components for a fully functional prototype are fabricated. The development program is on schedule. The last semi-annual report described the completion of the design refinement phase. This phase resulted in a Smart Screen design that meets performance targets both in the dry condition and with taconite slurry flow using PZT motors. This system was successfully demonstrated for the DOE and partner companies at the Coleraine Mineral Research Laboratory in Coleraine, Minnesota. Since then, the fabrication of the dry application prototype (incorporating an electromagnetic drive mechanism and a new deblinding concept) has been completed and successfully tested at QRDC's lab.« less
Risk of malnutrition (over and under-nutrition): validation of the JaNuS screening tool.
Donini, Lorenzo M; Ricciardi, Laura Maria; Neri, Barbara; Lenzi, Andrea; Marchesini, Giulio
2014-12-01
Malnutrition (over and under-nutrition) is highly prevalent in patients admitted to hospital and it is a well-known risk factor for increased morbidity and mortality. Nutritional problems are often misdiagnosed, and especially the coexistence of over and undernutrition is not usually recognized. We aimed to develop and validate a screening tool for the easy detection and reporting of both undernutrition and overnutrition, specifically identifying the clinical conditions where the two types of malnutrition coexist. The study consisted of three phases: 1) selection of an appropriate study population (estimation sample) and of the hospital admission parameters to identify overnutrition and undernutrition; 2) combination of selected variables to create a screening tool to assess the nutritional risk in case of undernutrition, overnutrition, or the copresence of both the conditions, to be used by non-specialist health care professionals; 3) validation of the screening tool in a different patient sample (validation sample). Two groups of variables (12 for undernutrition, 7 for overnutrition) were identified in separate logistic models for their correlation with the outcome variables. Both models showed high efficacy, sensitivity and specificity (overnutrition, 97.7%, 99.6%, 66.6%, respectively; undernutrition, 84.4%, 83.6%, 84.8%). The logistic models were used to construct a two-faced test (named JaNuS - Just A Nutritional Screening) fitting into a two-dimension Cartesian coordinate graphic system. In the validation sample the JaNuS test confirmed its predictive value. Internal consistency and test-retest analysis provide evidence for the reliability of the test. The study provides a screening tool for the assessment of the nutritional risk, based on parameters easy-to-use by health care personnel lacking nutritional competence and characterized by excellent predictive validity. The test might be confidently applied in the clinical setting to determine the importance of malnutrition (including the copresence of over and undernutrition) as a risk factor for morbidity and mortality. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Buyze, J; Vanden Berghe, W; Hens, N; Kenyon, C
2018-02-01
There is considerable uncertainty as to the effectiveness of Neisseria gonorrhoeae (NG) screening in men who have sex with men. It is important to ensure that screening has benefits that outweigh the risks of increased antibiotics resistance. We develop a mathematical model to estimate the effectiveness of screening on prevalence. Separable Temporal Exponential family Random Graph Models are used to model the sexual relationships network, both with main and casual partners. Next, the transmission of Gonorrhoea is simulated on this network. The models are implemented using the R package 'statnet', which we adapted among other things to incorporate infection status at the pharynx, urethra and rectum separately and to distinguish between anal sex, oral sex and rimming. The different screening programmes compared are no screening, 3.5% of the population screened, 32% screened and 50% screened. The model simulates day-by-day evolution for 10 years of a population of 10 000. If half of the population would be screened, the prevalence in the pharynx decreases from 11.9% to 10.2%. We conclude that the limited impact of screening on NG prevalence may not outweigh the increased risk of antibiotic resistance.
Takechi, Hajime; Dodge, Hiroko H
2010-01-01
Aim It is highly desirable to develop a neuropsychological screening test which is sensitive to the early stage of Alzheimer’s disease (AD), and is easy to administer at the primary care physician’s (PCP’s) office. Methods Participants were 128 AD patients and 54 healthy volunteers. Brief cognitive screening tests were administered to the participants including the Mini-Mental State Examination (MMSE), Clock Drawing Test (CDT), Verbal Fluency Test (VFT), a Verbal Category Cued Memory test (CCMT) and the Scenery Picture Memory Test (SPMT). In the SPMT, a scenery picture of a living room containing 23 familiar objects was used. The administration of the SPMT comprised the first shallow memory session (Pict 1) and the second deep memory session (Pict 2). The area under the receiver–operator curve (AUC) was used to compare the efficacy of SPMT with other cognitive tests. Results Pict 1, which requires less than 2 min to complete, had the same AUC as Pict 2, and showed significantly larger AUC than MMSE, CDT and VFT for all (MMSE 19–23) and very mild (MMSE ≥ 24) AD patients. When we conducted the similar analysis separately for those younger than 75 years and those aged 75 years or older, we obtained the same results as above among the older age group. Pict 1 showed larger AUC than CCMT in overall sample and also in the older age group, although the difference was not statistically significant. Conclusion The SPMT could be useful for detection of mild and very mild AD in settings even where time is limited. PMID:20446933
Huang, Marilyn; Sun, Charlotte; Boyd-Rogers, Stephanie; Burzawa, Jennifer; Milbourne, Andrea; Keeler, Elizabeth; Yzquierdo, Rebecca; Lynch, Patrick; Peterson, Susan K.; Lu, Karen
2011-01-01
Background: Endometrial and colorectal cancers are the most common cancers in Lynch syndrome. Consensus guidelines recommend annual endometrial biopsy (EMB) and regular colonoscopies. We assessed the feasibility of concurrently performing EMB and colonoscopy and evaluated women's perception of pain, satisfaction, and acceptability. Methods: From July 2002 to December 2009, women who had a gene mutation for Lynch syndrome, met the Amsterdam II criteria, or had a high-risk situation that required screening were prospectively enrolled. After conscious sedation, the procedures were sequentially performed. Patients completed pre- and postprocedure questionnaires assessing pain, level of satisfaction, and acceptability. The Wilcoxon rank test and Mann-Whitney test were used to compare pain scores. Results: Forty-two women completed the study. Median age was 37 years (range, 25 to 73). Nineteen had previously had an EMB in the office setting. Women reported significantly lower median levels of pain in the combined procedure compared with previous office setting biopsies (P < .001). Regardless of parity, women reported significantly less pain for an EMB as part of the combined screen compared with an office EMB (parous, P = .003; nulliparous, P = .026). Women also reported a high level of satisfaction and more convenience in the combined procedure. All participants preferred combined to separately scheduled procedures and would recommend the combined procedure to their relatives. Conclusion: Combined colon and endometrial cancer screening is a patient-centered approach that is feasible, acceptable, and may improve adherence to Lynch syndrome screening recommendations. PMID:21532810
Criteria To Screen for Chronic Sinonasal Disease
Dixon, Anne E.; Sugar, Elizabeth A.; Zinreich, S. James; Slavin, Raymond G.; Corren, Jonathan; Naclerio, Robert M.; Ishii, Masaru; Cohen, Rubin I.; Brown, Ellen D.; Wise, Robert A.; Irvin, Charles G.
2009-01-01
Background: Sinusitis and rhinitis are associated with uncontrolled asthma. There are no simple, validated tools to screen for these diseases. The objective of this study was to assess instruments to assist in the diagnosis of chronic sinonasal disease. Methods: Participants without acute sinonasal symptoms underwent an extensive evaluation. The results were submitted to an expert panel that used the Delphi method to achieve consensus. Using the consensus diagnosis of the panel, we determined the sensitivity and specificity of test procedures to diagnose chronic sinonasal disease. We determined the reproducibility of the most sensitive and specific instrument in a separate cohort. Results: Fifty-nine participants were evaluated, and the expert panel reached consensus for all (42 participants with chronic sinonasal disease, 17 participants without chronic sinonasal disease). A six-item questionnaire based on the frequency of nasal symptoms was the most sensitive tool used to diagnose sinonasal disease (minimum specificity, 0.90). Reproducibility testing in a separate cohort of 63 participants (41 chronic sinonasal disease with asthma, 22 chronic sinonasal disease without asthma) showed a concordance correlation coefficient of 0.91 (95% CI, 0.85 to 0.94) when this questionnaire was limited to five items (ie, excluding a question on smell). This five-item questionnaire had a sensitivity of 0.90 (95% CI, 0.77 to 0.97), a specificity of 0.94 (95% CI, 0.71 to 1.00), and an area under the receiver operating characteristic curve of 0.97 (95% CI, 0.93 to 1.0). Sinus CT scans and nasal endoscopy lacked sensitivity for use in the diagnosis of chronic sinonasal disease. Conclusions: We have developed a sensitive, specific, and reproducible instrument to screen for chronic sinonasal disease. Validation studies of this five-item questionnaire are needed, including in patients with asthma. PMID:19581356
Trends in colorectal cancer screening over time for persons with and without chronic disability.
Iezzoni, Lisa I; Kurtz, Stephen G; Rao, Sowmya R
2016-07-01
Persons with disabilities have often experienced disparities in routine cancer screening. However, with civil rights protections from the 1990 Americans with Disabilities Act, such disparities may diminish over time. To examine whether disability disparities exist for colorectal cancer screening and whether these screening patterns have changed over time. We analyzed National Health Interview Survey responses from civilian, non-institutionalized U.S. residents 50-75 years old from selected years between 1998 and 2010. We specified 7 chronic disability indicators using self-reported functional impairments, activity/participation limitations, and expected duration. Separately for women and men, we conducted bivariable and multivariable logistic regression analyses examining associations of self-reported colorectal cancer screening services with sociodemographic factors and disability type. Patterns of chronic disability differed somewhat between women and men; disability rates generally rose over time. For both women and men, colorectal cancer screening rates increased substantially from 1998 through 2010. Over time, relatively few statistically significant differences were reported in colorectal cancer screening rates between nondisabled persons and individuals with various disabilities. In 2010, reported screening rates were generally comparable between nondisabled and disabled persons. In the few statistically significant differences, persons with disabilities almost always reported higher colorectal cancer screening rates than nondisabled individuals. According to national survey data, reported use of colorectal cancer screening is similar between nondisabled persons and individuals with a variety of different disability types. Despite physical demands of some colorectal cancer screening tests, disparities do not appear between populations with and without disability. Copyright © 2016 Elsevier Inc. All rights reserved.
A microfluidic array for high-content screening at whole-organism resolution
NASA Astrophysics Data System (ADS)
Migliozzi, D.; Cornaglia, M.; Mouchiroud, L.; Auwerx, J.; Gijs, M. A. M.
2018-02-01
A main step for the development and the validation of medical drugs is the screening on whole organisms, which gives the systemic information that is missing when using cellular models. Among the organisms of choice, Caenorhabditis elegansis a soil worm which catches the interest of researchers who study systemic physiopathology (e.g. metabolic and neurodegenerative diseases) because: (1) its large genetic homology with humans supports translational analysis; (2) worms are much easier to handle and grow in large amounts compared to rodents, for which (3) the costs and (4) the ethical concerns are substantial.C. elegansis therefore well suited for large screens, dose-response analysis and target-discovery involving an entire organism. We have developed and tested a microfluidic array for high-content screening, enabling the selection of small populations of its first larval stage in many separated chambers divided into channels for multiplexed screens. With automated protocols for feeding, drug administration and image acquisition, our chip enables the study of the nematodes throughout their entire lifespan. By using a paralyzing agent and a mitochondrial-stress inducer as case studies, we have demonstrated large field-of-view motility analysis, and worm-segmentation/signal-detection for mode-of-action quantification with genetically-encoded fluorescence reporters.
Debrus, B; Lebrun, P; Kindenge, J Mbinze; Lecomte, F; Ceccato, A; Caliaro, G; Mbay, J Mavar Tayey; Boulanger, B; Marini, R D; Rozet, E; Hubert, Ph
2011-08-05
An innovative methodology based on design of experiments (DoE), independent component analysis (ICA) and design space (DS) was developed in previous works and was tested out with a mixture of 19 antimalarial drugs. This global LC method development methodology (i.e. DoE-ICA-DS) was used to optimize the separation of 19 antimalarial drugs to obtain a screening method. DoE-ICA-DS methodology is fully compliant with the current trend of quality by design. DoE was used to define the set of experiments to model the retention times at the beginning, the apex and the end of each peak. Furthermore, ICA was used to numerically separate coeluting peaks and estimate their unbiased retention times. Gradient time, temperature and pH were selected as the factors of a full factorial design. These retention times were modelled by stepwise multiple linear regressions. A recently introduced critical quality attribute, namely the separation criterion (S), was also used to assess the quality of separations rather than using the resolution. Furthermore, the resulting mathematical models were also studied from a chromatographic point of view to understand and investigate the chromatographic behaviour of each compound. Good adequacies were found between the mathematical models and the expected chromatographic behaviours predicted by chromatographic theory. Finally, focusing at quality risk management, the DS was computed as the multidimensional subspace where the probability for the separation criterion to lie in acceptance limits was higher than a defined quality level. The DS was computed propagating the prediction error from the modelled responses to the quality criterion using Monte Carlo simulations. DoE-ICA-DS allowed encountering optimal operating conditions to obtain a robust screening method for the 19 considered antimalarial drugs in the framework of the fight against counterfeit medicines. Moreover and only on the basis of the same data set, a dedicated method for the determination of three antimalarial compounds in a pharmaceutical formulation was optimized to demonstrate both the efficiency and flexibility of the methodology proposed in the present study. Copyright © 2011 Elsevier B.V. All rights reserved.
Passive gas separator and accumulator device
Choe, H.; Fallas, T.T.
1994-08-02
A separation device employing a gas separation filter and swirler vanes for separating gas from a gas-liquid mixture is provided. The cylindrical filter utilizes the principle that surface tension in the pores of the filter prevents gas bubbles from passing through. As a result, the gas collects in the interior region of the filter and coalesces to form larger bubbles in the center of the device. The device is particularly suited for use in microgravity conditions since the swirlers induce a centrifugal force which causes liquid to move from the inner region of the filter, pass the pores, and flow through the outlet of the device while the entrained gas is trapped by the filter. The device includes a cylindrical gas storage screen which is enclosed by the cylindrical gas separation filter. The screen has pores that are larger than those of the filters. The screen prevents larger bubbles that have been formed from reaching and interfering with the pores of the gas separation filter. The device is initially filled with a gas other than that which is to be separated. This technique results in separation of the gas even before gas bubbles are present in the mixture. Initially filling the device with the dissimilar gas and preventing the gas from escaping before operation can be accomplished by sealing the dissimilar gas in the inner region of the separation device with a ruptured disc which can be ruptured when the device is activated for use. 3 figs.
Passive gas separator and accumulator device
Choe, Hwang; Fallas, Thomas T.
1994-01-01
A separation device employing a gas separation filter and swirler vanes for separating gas from a gasliquid mixture is provided. The cylindrical filter utilizes the principle that surface tension in the pores of the filter prevents gas bubbles from passing through. As a result, the gas collects in the interior region of the filter and coalesces to form larger bubbles in the center of the device. The device is particularly suited for use in microgravity conditions since the swirlers induce a centrifugal force which causes liquid to move from the inner region of the filter, pass the pores, and flow through the outlet of the device while the entrained gas is trapped by the filter. The device includes a cylindrical gas storage screen which is enclosed by the cylindrical gas separation filter. The screen has pores that are larger than those of the filters. The screen prevents larger bubbles that have been formed from reaching and interfering with the pores of the gas separation filter. The device is initially filled with a gas other than that which is to be separated. This technique results in separation of the gas even before gas bubbles are present in the mixture. Initially filling the device with the dissimilar gas and preventing the gas from escaping before operation can be accomplished by sealing the dissimilar gas in the inner region of the separation device with a ruptured disc which can be ruptured when the device is activated for use.
Trials and projects on cervical cancer and human papillomavirus prevention in sub-Saharan Africa.
Adefuye, Peter O; Broutet, Nathalie J; de Sanjosé, Silvia; Denny, Lynette A
2013-12-29
Cervical cancer is the leading cause of cancer morbidity and mortality in women in sub-Saharan Africa (SSA), accounting for about 50,000 deaths annually. Until recently, cytology was the gold standard for screening and prevention of cervical cancer. This method of screening has not been successful in SSA due to a lack of human, financial and material resources and poor health care infrastructure. It is estimated that less than 5% of at risk women have ever being screened. In the past two decades alternative approaches to cytology for cervical cancer screening have been evaluated in low- and medium-income countries. Visual inspection with acetic acid (VIA) and/or Lugol's iodine (VILI) have been shown to have adequate sensitivity, although low specificity, in a number of cross-sectional research and demonstration projects. Visual inspection methods require minimal resources, are technologically accessible, and are feasible for screening for precancerous lesions. Linking screening with VIA/VILI to treatment with cryotherapy may enable screening and treatment to take place in one visit, but this is likely to result in large numbers of women being subjected to unnecessary treatment. A number of studies have shown that cryotherapy is not associated with significant side effects or complications and is well tolerated. Creating the infrastructure for screening of older women is considered desirable, despite the limitations of visual inspection methods as screening tests. Understanding the role of human papillomavirus (HPV) infection in the etiology of cervical cancer and the discovery of HPV rapid test kits, as well as the development of vaccines against the HPV oncogenic types, have created new opportunities for prevention of cervical cancer. Trials and projects have established (and are still ongoing) the feasibility of using these molecular tests for screening. The ultimate in prevention method is primary prevention, offered by the advent of prophylactic vaccines against the most important oncogenic types, namely HPV16 and 18. This article forms part of a regional report entitled "Comprehensive Control of HPV Infections and Related Diseases in the Sub-Saharan Africa Region" Vaccine Volume 31, Supplement 5, 2013. Updates of the progress in the field are presented in a separate monograph entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2012 Elsevier Ltd. All rights reserved.
Characterization and Separation of Cancer Cells with a Wicking Fiber Device.
Tabbaa, Suzanne M; Sharp, Julia L; Burg, Karen J L
2017-12-01
Current cancer diagnostic methods lack the ability to quickly, simply, efficiently, and inexpensively screen cancer cells from a mixed population of cancer and normal cells. Methods based on biomarkers are unreliable due to complexity of cancer cells, plasticity of markers, and lack of common tumorigenic markers. Diagnostics are time intensive, require multiple tests, and provide limited information. In this study, we developed a novel wicking fiber device that separates cancer and normal cell types. To the best of our knowledge, no previous work has used vertical wicking of cells through fibers to identify and isolate cancer cells. The device separated mouse mammary tumor cells from a cellular mixture containing normal mouse mammary cells. Further investigation showed the device separated and isolated human cancer cells from a heterogeneous mixture of normal and cancerous human cells. We report a simple, inexpensive, and rapid technique that has potential to identify and isolate cancer cells from large volumes of liquid samples that can be translated to on-site clinic diagnosis.
Parekh, Natasha; Donohue, Julie M; Men, Aiju; Corbelli, Jennifer; Jarlenski, Marian
2017-01-01
To assess changes in cervical cancer screening after the 2009 American College of Obstetricians and Gynecologists' guideline change and to determine predictors associated with underscreening and overscreening among Medicaid-enrolled women. We performed an observational cohort study of Pennsylvania Medicaid claims from 2007 to 2013. We evaluated guideline adherence of 18- to 64-year-old continuously enrolled women before and after the 2009 guideline change. To define adherence, we categorized intervals between Pap tests as longer than (underscreening), within (appropriate screening), or shorter than (overscreening) guideline-recommended intervals (±6-month). We stratified results by age and assessed predictors of underscreening and overscreening through logistic regression. Among 29,650 women, appropriate cervical cancer screening significantly decreased after the guideline change (from 45% [95% confidence interval (CI) 44-46%] to 11% [95% CI 11-12%] among 17,360 younger than 30 year olds and from 27% [95% CI 26-28%] to 6% [95% CI 6-7%] among 12,290 women 30 years old or older). Overscreening significantly increased (from 6% [95% CI 5-6%] to 67% [95% CI 66-68%] in those younger than 30 years old and from 54% [95% CI 52-55%] to 65% [95% CI 64-67%] in those 30 years old or older), whereas underscreening significantly increased only in those 30 years old or older (from 20% [95% CI 19-21%] to 29% [95% CI 27-30%]). Pap tests after guideline change, pregnancy, Managed Care enrollment (in those younger than 30 years old), and black race (in those younger than 30 years old) were associated with underscreening. Pap tests after guideline change, more visits, more sexually transmitted infection testing, and white race (in those 30 years old or older) were associated with overscreening. We observed high rates of cervical cancer overscreening and underscreening and low rates of appropriate screening after the guideline change. Interventions should target both underscreening and overscreening to address these separate yet significant issues.
Zietemann, Vera; Kopczak, Anna; Müller, Claudia; Wollenweber, Frank Arne; Dichgans, Martin
2017-11-01
Assessment of cognitive status poststroke is recommended by guidelines but follow-up can often not be done in person. The Telephone Interview of Cognitive Status (TICS) and the Telephone Montreal Cognitive Assessment (T-MoCA) are considered useful screening instruments. Yet, evidence to define optimal cut-offs for mild cognitive impairment (MCI) after stroke is limited. We studied 105 patients enrolled in the prospective DEDEMAS study (Determinants of Dementia After Stroke; NCT01334749). Follow-up visits at 6, 12, 36, and 60 months included comprehensive neuropsychological testing and the Clinical Dementia Rating scale, both of which served as reference standards. The original TICS and T-MoCA were obtained in 2 separate telephone interviews each separated from the personal visits by 1 week (1 before and 1 after the visit) with the order of interviews (TICS versus T-MoCA) alternating between subjects. Area under the receiver-operating characteristic curves was determined. Ninety-six patients completed both the face-to-face visits and the 2 interviews. Area under the receiver-operating characteristic curves ranged between 0.76 and 0.83 for TICS and between 0.73 and 0.94 for T-MoCA depending on MCI definition. For multidomain MCI defined by multiple-tests definition derived from comprehensive neuropsychological testing optimal sensitivities and specificities were achieved at cut-offs <36 (TICS) and <18 (T-MoCA). Validity was lower using single-test definition, and cut-offs were higher compared with multiple-test definitions. Using Clinical Dementia Rating as the reference, optimal cut-offs for MCI were <36 (TICS) and approximately 19 (T-MoCA). Both the TICS and T-MoCA are valid screening tools poststroke, particularly for multidomain MCI using multiple-test definition. © 2017 American Heart Association, Inc.
Motivational interviewing and colorectal cancer screening: a peek from the inside out.
Wahab, Stéphanie; Menon, Usha; Szalacha, Laura
2008-08-01
This article focuses on design, training, and delivery of motivational interview (MI) in a longitudinal randomized controlled trial intended to assess the efficacy of two separate interventions designed to increase colorectal screening when compared to a usual care, control group. One intervention was a single-session, telephone-based MI, created to increase colorectal cancer screening within primary care populations. The other was tailored health counseling. We present the rationale, design, and process discussions of the one-time motivational interviewing telephone intervention. We discuss in this paper the training and supervision of study interventionists, in order to enhance practice and research knowledge concerned with fidelity issues in motivational interview interventions. To improve motivational interviewing proficiency and effectiveness, we developed a prescribed training program adapting MI to a telephone counseling session. The three interventionists trained in MI demonstrate some MI proficiency assessed by the motivational interviewing treatment integrity scale. In the post-intervention interview, 20.5% of the MI participants reported having had a CRC screening test, and another 19.75% (n=16) had scheduled a screening test. Almost half of the participants (43%) indicated that the phone conversation helped them to overcome the reasons why they had not had a screening test. Ongoing supervision and training (post-MI workshop) are crucial to supporting MI fidelity. The trajectory of learning MI demonstrated by the interventionists is consistent with the eight stages of learning MI. The MI road map created for the interventionists has shown to be more of a distraction than a facilitator in the delivery of the telephone intervention. MI can, however, be considered a useful tool for health education and warrants further study. MI training should include consistent training and process evaluation. MI can, however, be considered a useful tool for health education and warrants further study. MI can also be adapted to diverse health promotion scenarios.
Gonzalo-Lumbreras, Raquel; Sanz-Landaluze, Jon; Cámara, Carmen
2015-07-01
The behavior of 15 benzimidazoles, including their main metabolites, using several C18 columns with standard or narrow-bore diameters and different particle size and type were evaluated. These commercial columns were selected because their differences could affect separation of benzimidazoles, and so they can be used as alternative columns. A simple screening method for the analysis of benzimidazole residues and their main metabolites was developed. First, the separation of benzimidazoles was optimized using a Kinetex C18 column; later, analytical performances of other columns using the above optimized conditions were compared and then individually re-optimized. Critical pairs resolution, analysis run time, column type and characteristics, and selectivity were considered for chromatographic columns comparison. Kinetex XB was selected because it provides the shortest analysis time and the best resolution of critical pairs. Using this column, the separation conditions were re-optimized using a factorial design. Separations obtained with the different columns tested can be applied to the analysis of specific benzimidazoles residues or other applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The pros and cons of the fourth revision of thalassaemia screening programme in Iran.
Moafi, Alireza; Vallian, Reihaneh; Vallian, Sadeq; Rahgozar, Soheila; Torfenajad, Mohammad; Moafi, Hadi
2017-03-01
Objective To evaluate the repercussions of recent changes to the cut-offs used in the first screening step of the pre-marital screening programme for thalassaemia prevention in Iran. Methods The profiles of 984 subjects referred to a genetic laboratory, and the tests of 242 parents of children with thalassaemia major were assessed for red blood cell (RBC) indices, haemoglobin (Hb) A2 levels and results of Hb electrophoresis. Results Of 407 suspected thalassaemia minor (STM) cases, 18 proved positive for thalassaemia minor on molecular analysis (18/407, confidence interval 2.6-6.9%). If the revised screening cut-offs had been used to determine who would undergo molecular analysis, two of these cases would not have been identified. Only 4.4% of suspected cases with lower than normal RBC indices (mean corpuscular volume <80 fl and mean corpuscular Hb <27 pg) and HbA2 (<3.5%) were diagnosed with thalassaemia minor. Conclusion The thalassaemia major prevention programme is performed in two separate steps. One step involves the screening of subjects and identification of β-thalassaemia minor, suspected cases for thalassaemia minor (STM), and normal subject groups. The other step concerns the identification of thalassaemia minor in the STM group. Changing the cut-offs at the first screening step does not result in significant improvement from an economic view, and is associated with significant risk at the second screening step.
Debiasing comparative optimism and increasing worry for health outcomes.
Rose, Jason P
2012-11-01
Comparative optimism - feeling at less personal risk for negative outcomes than one's peers - has been linked to reduced prevention efforts. This study examined a novel debiasing technique aimed at simultaneously reducing both indirectly and directly measured comparative optimism. Before providing direct comparative estimates, participants provided absolute self and peer estimates in a joint format (same computer screen) or a separate format (different computer screens). Relative to the separate format condition, participants in the joint format condition showed (1) lower comparative optimism in absolute/indirect measures, (2) lower direct comparative optimism, and (3) heightened worry. Implications for risk perception screening are discussed.
Integrality and separability of multitouch interaction techniques in 3D manipulation tasks.
Martinet, Anthony; Casiez, Géry; Grisoni, Laurent
2012-03-01
Multitouch displays represent a promising technology for the display and manipulation of data. While the manipulation of 2D data has been widely explored, 3D manipulation with multitouch displays remains largely unexplored. Based on an analysis of the integration and separation of degrees of freedom, we propose a taxonomy for 3D manipulation techniques with multitouch displays. Using that taxonomy, we introduce Depth-Separated Screen-Space (DS3), a new 3D manipulation technique based on the separation of translation and rotation. In a controlled experiment, we compared DS3 with Sticky Tools and Screen-Space. Results show that separating the control of translation and rotation significantly affects performance for 3D manipulation, with DS3 performing faster than the two other techniques.
Nor, Azimah; Zabedah, Md Yunus; Norsiah, Md Desa; Ngu, Lock Hock; Suhaila, Abd Rahman
2010-06-01
Mucopolysaccharidoses (MPS) are a group of inherited disorders caused by the deficiency of specific lysosomal enzymes involved in glycosaminoglycans (GAGs) degradation. Currently, there are 11 enzyme deficiencies resulting in seven distinct MPS clinical syndromes and their subtypes. Different MPS syndromes cannot be clearly distinguished clinically due to overlapping signs and symptoms. Measurement of GAGs content in urine and separation of GAGs using high-resolution electrophoresis (HRE) are very useful initial screening tests for isotyping of MPS before specific enzyme diagnostics. In this study, we measured total urinary GAGs by a method using dimethylmethylene blue (DMB), and followed by isolation and separation of GAGs using high resolution electrophoresis (HRE) technique. Of 760 urine samples analyzed, 40 have abnormal GAGs HRE patterns. Thirty-five of these 40 cases have elevated urinary GAGs levels as well. These abnormal HRE patterns could be classified into 4 patterns: Pattern A (elevated DS and HS; suggestive of MPS I, II or VII; 16 cases), Pattern B (elevated HS and CS; suggestive of MPS III; 17 cases), and Pattern C (elevated KS and CS; suggestive of MPS IV, 5 cases), and Pattern D (elevated DS; suggestive of MPS VI; 2 cases). Based on the GAGs HRE pattern and a few discriminating clinical signs, we performed selective enzymatic investigation in 16 cases. In all except one case with MPS VII, the enzymatic diagnosis correlated well with the provisional MPS type as suggested by the abnormal HRE pattern. Our results showed that GAGs HRE is a useful, inexpensive and practical first-line screening test when MPS is suspected clinically, and it provides an important guide to further enzymatic studies on a selective basis.
Novel microfluidic device for the continuous separation of cancer cells using dielectrophoresis.
Alazzam, Anas; Mathew, Bobby; Alhammadi, Falah
2017-03-01
We describe the design, microfabrication, and testing of a microfluidic device for the separation of cancer cells based on dielectrophoresis. Cancer cells, specifically green fluorescent protein-labeled MDA-MB-231, are successfully separated from a heterogeneous mixture of the same and normal blood cells. MDA-MB-231 cancer cells are separated with an accuracy that enables precise detection and counting of circulating tumor cells present among normal blood cells. The separation is performed using a set of planar interdigitated transducer electrodes that are deposited on the surface of a glass wafer and slightly protrude into the separation microchannel at one side. The device includes two parts, namely, a glass wafer and polydimethylsiloxane element. The device is fabricated using standard microfabrication techniques. All experiments are conducted with low conductivity sucrose-dextrose isotonic medium. The variation in response between MDA-MB-231 cancer cells and normal cells to a certain band of alternating-current frequencies is used for continuous separation of cells. The fabrication of the microfluidic device, preparation of cells and medium, and flow conditions are detailed. The proposed microdevice can be used to detect and separate malignant cells from heterogeneous mixture of cells for the purpose of early screening for cancer. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Factors affecting reproducibility between genome-scale siRNA-based screens
Barrows, Nicholas J.; Le Sommer, Caroline; Garcia-Blanco, Mariano A.; Pearson, James L.
2011-01-01
RNA interference-based screening is a powerful new genomic technology which addresses gene function en masse. To evaluate factors influencing hit list composition and reproducibility, we performed two identically designed small interfering RNA (siRNA)-based, whole genome screens for host factors supporting yellow fever virus infection. These screens represent two separate experiments completed five months apart and allow the direct assessment of the reproducibility of a given siRNA technology when performed in the same environment. Candidate hit lists generated by sum rank, median absolute deviation, z-score, and strictly standardized mean difference were compared within and between whole genome screens. Application of these analysis methodologies within a single screening dataset using a fixed threshold equivalent to a p-value ≤ 0.001 resulted in hit lists ranging from 82 to 1,140 members and highlighted the tremendous impact analysis methodology has on hit list composition. Intra- and inter-screen reproducibility was significantly influenced by the analysis methodology and ranged from 32% to 99%. This study also highlighted the power of testing at least two independent siRNAs for each gene product in primary screens. To facilitate validation we conclude by suggesting methods to reduce false discovery at the primary screening stage. In this study we present the first comprehensive comparison of multiple analysis strategies, and demonstrate the impact of the analysis methodology on the composition of the “hit list”. Therefore, we propose that the entire dataset derived from functional genome-scale screens, especially if publicly funded, should be made available as is done with data derived from gene expression and genome-wide association studies. PMID:20625183
Goldsmith, Megan R; Bankhead, Clare R; Kehoe, Sean T; Marsh, Gill; Austoker, Joan
2007-01-01
To explore women's attitudes towards the information about human papilloma virus (HPV) provided during cervical screening and to describe women's HPV information needs. Women with a range of screening results (normal, inadequate, borderline and abnormal) were identified by three screening centres in England. Two consecutive samples of women attending for colposcopy for the first time following screening were also approached. Seven focus groups were conducted between May 2005 and April 2006 with 38 women who had recently been for cervical screening or had attended a colposcopy appointment. Most women had no prior awareness of HPV. Many women queried the importance of being informed about HPV as no preventive advice or treatment is available. The HPV information included in the UK national screening programme abnormal result leaflet left women with more questions than answers (a list of unanswered questions is included with the results). Further information was requested about HPV detection, infection and transmission as well as the natural history and progression of cervical cancer. No consensus was reached regarding the best time to provide HPV information. Clear communication of the complicated issues surrounding HPV infection and the natural history of cervical cancer is a considerable educational challenge for screening providers. As awareness of HPV becomes more widespread and HPV testing is explored as a triage during cervical screening, women are likely to require more information about the virus and the implications of infection. Consideration should be given to the production of a separate national screening programme HPV leaflet.
Intersession reliability of self-selected and narrow stance balance testing in older adults.
Riemann, Bryan L; Piersol, Kelsey
2017-10-01
Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P < .05) occurred between the testing sessions for any of the tests. The standard error of measurement ranged from 15.9 to 23.6%. Reliability estimates were similar between the two stances and visual conditions assessed. Slightly higher coefficients were identified for the self-selected stances compared to the narrow stances under both visual conditions; however, there were negligible differences between the sessions. The within subject session-to-session variability provides a basis for further research to consider differences between fallers and non-fallers. Reliability for eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.
Kou, Kam On; Poon, Chung Fan; Tse, Wai Ching; Mak, Shui Lam; Leung, Kwok Yin
2015-09-02
Despite the non-invasive nature of non-invasive prenatal testing (NIPT), there is still a need for a separate informed consent process before testing. The objectives of this study are to assess (a) knowledge and preferences of Chinese women in a major public hospital in Hong Kong who underwent NIPT, and (b) whether their knowledge and preferences differ depending on womens' characteristics and sources of information. Setting: Prenatal diagnosis and counselling clinic. Between February 2012 and September 2013, a questionnaire survey was distributed to all women who underwent NIPT after positive aneuploidy screening. As a pilot study, ten knowledge questions were designed based on the rapid response statement on Prenatal Detection of Down Syndrome using Massively Parallel Sequencing from the International Society for Prenatal Diagnosis in 2011. The source of women's knowledge and their preferences were also evaluated. While conventional screening was publicly funded, NIPT was not. Differences between subgroups were compared using chi square tests and logistic regression analysis. Of 152 women who underwent NIPT, 135 (88.8%) completed their questionnaires. More than 90% of women recognised the possibility of false positive and false negative results. Slightly more than 70% of women knew the inferior sensitivity of NIPT compared to an invasive test, and the possibility of an uninformative test result, but were not aware of the complicated aspects of NIPT. Pregnant women with an advanced level of education or those who underwent NIPT before 15 weeks provided answers that was more accurate by around 10-20% in two to three knowledge questions than those without. These associations were confirmed by multivariate logistic regression analysis. The women received information on NIPT largely from their private doctors (47.4%) and web (41.5%). In their future pregnancies, more women would opt for NIPT (a self-financed item) after positive screening ('free' in a public hospital) (57.8%) than as a primary screening (30.4%). It is feasible to use a questionnaire based on the ISPD statement on NIPT to assess women's knowledge of the test. The Chinese women who underwent NIPT recognised the limitations, but did not understand the complicated aspects. More information should be provided by health care professionals in order to facilitate an informed choice by patients. More women preferred NIPT as a contingent test than as a primary screening probably because of its high cost.
Dynamic balance control in elders: gait initiation assessment as a screening tool
NASA Technical Reports Server (NTRS)
Chang, H.; Krebs, D. E.; Wall, C. C. (Principal Investigator)
1999-01-01
OBJECTIVE: To determine whether measurements of center of gravity-center of pressure separation (CG-CP moment arm) during gait initiation can differentiate healthy from disabled subjects with sufficient specificity and sensitivity to be useful as a screening test for dynamic balance in elderly patients. SUBJECTS: Three groups of elderly subjects (age, 74.97+/-6.56 yrs): healthy elders (HE, n = 21), disabled elders (DE, n = 20), and elders with vestibular hypofunction (VH, n = 18). DESIGN: Cross-sectional, intact-groups research design. Peak CG-CP moment arm measures how far the subject will tolerate the whole-body CG to deviate from the ground reaction force's CP; it represents dynamic balance control. Screening test cutoff points at 16 to 18 cm peak CG-CP moment arm predicted group membership. RESULTS: The magnitude of peak CG-CP moment arm was significantly greater in HE than in DE and VH subjects (p<.01) and was not different between the DE and VH groups. The peak CG-CP moment arm occurred at the end of single stance phase in all groups. As a screening test, the peak moment arm has greater than 50% sensitivity and specificity to discriminate the HE group from the DE and VH groups with peak CG-CP moment arm cutoff points between 16 and 18 cm. CONCLUSIONS: Examining dynamic balance through the use of the CG-CP moment arm during single stance in gait initiation discriminates between nondisabled and disabled older persons and warrants further investigation as a potential tool to identify people with balance dysfunction.
Whitley, Elizabeth M; Raich, Peter C; Dudley, Donald J; Freund, Karen M; Paskett, Electra D; Patierno, Steven R; Simon, Melissa; Warren-Mears, Victoria; Snyder, Frederick R
2016-01-01
Background Whether patient navigation improves outcomes in patients with comorbidities is unknown. Study aims were to determine the effect of comorbidities on time to diagnostic resolution following an abnormal cancer screening test, and to examine for patients with comorbidities, if patient navigation improves timeliness and likelihood of diagnostic resolution compared to patients without navigation. Methods A secondary analysis from the Patient Navigation Research Program sites that collected comorbidity data using the Charlson Comorbidity Index (CCI) was conducted. Participants were 6,349 patients with abnormal breast, cervical, colon or prostate cancer screening tests between 2007 and 2011. The intervention was patient navigation or usual care. CCI data were highly skewed across projects and cancer sites and were categorized as 0, no comorbidities identified, CCI score of 0 (76% of cases); 1, CCI score of 1 (16% of cases); or 2, CCI score of ≥2 (8% of cases). A separate adjusted hazards ratio for each site and cancer type was obtained, and then pooled using meta-analysis random effects methodology. Results Having a CCI score of ≥2 delayed the time to diagnostic resolution following an abnormal cancer screening test compared with those with fewer than one comorbidity. Patient Navigation reduced delays in diagnostic resolution with the greatest benefit seen in those with a CCI score of ≥2. Conclusions Persons with a CCI score of ≥2 experienced significant delays in timely diagnostic care compared to patients without comorbidities. Patient navigation was effective in reducing delays in diagnostic resolution among those with CCI scores > 1. PMID:27648520
Post-mortem genetic testing in a family with long-QT syndrome and hypertrophic cardiomyopathy.
Kane, David A; Triedman, John
2014-01-01
Pediatric sudden unexplained deaths are rare and tragic events that should be evaluated with all the tools available to the medical community. The current state of genetic testing is an excellent resource that improves our ability to diagnose cardiovascular disorders that can lead to sudden cardiac arrest. Post-mortem genetic testing is not typically a covered benefit of health insurance and may not be offered to families in the setting of a negative autopsy. This unusual case includes two separate cardiovascular disorders that highlight the use of genetic testing and its role in diagnosis, screening, and risk stratification. The insurance company's decision to cover post-mortem testing demonstrated both compassion as well as an understanding of the long-term cost effectiveness. Copyright © 2014 Elsevier Inc. All rights reserved.
Rogé, Stijn; Van Nieuwenhove, Liesbeth; Meul, Magali; Heykers, Annick; Brouwer de Koning, Annette; Bebronne, Nicolas; Guisez, Yves; Büscher, Philippe
2014-07-01
Screening tests for gambiense sleeping sickness, such as the CATT/T. b. gambiense and a recently developed lateral flow tests, are hitherto based on native variant surface glycoproteins (VSGs), namely LiTat 1.3 and LiTat 1.5, purified from highly virulent trypanosome strains grown in rodents. We have expressed SUMO (small ubiquitin-like modifier) fusion proteins of the immunogenic N-terminal part of these antigens in the yeast Pichia pastoris. The secreted recombinant proteins were affinity purified with yields up to 10 mg per liter cell culture. The diagnostic potential of each separate antigen and a mixture of both antigens was confirmed in ELISA on sera from 88 HAT patients and 74 endemic non-HAT controls. Replacement of native antigens in the screening tests for sleeping sickness by recombinant proteins will eliminate both the infection risk for the laboratory staff during antigen production and the need for laboratory animals. Upscaling production of recombinant antigens, e.g. in biofermentors, is straightforward thus leading to improved standardisation of antigen production and reduced production costs, which on their turn will increase the availability and affordability of the diagnostic tests needed for the elimination of gambiense HAT.
Gimeno, Pascal; Maggio, Annie-Françoise; Bancilhon, Marjorie; Lassu, Nelly; Gornes, Hervé; Brenier, Charlotte; Lempereur, Laurent
2016-03-01
Corticosteroids, hydroquinone and its ethers are regulated in cosmetics by the Regulation 1223/2009. As corticosteroids are forbidden to be used in cosmetics and cannot be present as contaminants or impurities, an identification of one of these illicit compounds deliberately introduced in these types of cosmetics is enough for market survey control. In order to quickly identify skin-whitening agents present in illegal cosmetics, this article proposes an HPLC-UV method for the identification and screening of hydroquinone, 3 ethers of hydroquinone and 39 corticosteroids that may be found in skin-whitening products. Two elution gradients were developed to separate all compounds. The main solvent gradient (A) allows the separation of 39 compounds among the 43 compounds considered in 50 min. Limits of detection on skin-whitening cosmetics are given. For compounds not separated, a complementary gradient elution (B) using the same solvents is proposed. Between 2004 and 2009, a market survey on "skin-whitening cosmetic" was performed on 150 samples and highlights that more than half of the products tested do not comply with the Cosmetic Regulation 1223/2009 (amending the Council Directive 76/768/EEC). © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Pharmacophore Based Virtual Screening Approach to Identify Selective PDE4B Inhibitors
Gaurav, Anand; Gautam, Vertika
2017-01-01
Phosphodiesterase 4 (PDE4) has been established as a promising target in asthma and chronic obstructive pulmonary disease. PDE4B subtype selective inhibitors are known to reduce the dose limiting adverse effect associated with non-selective PDE4B inhibitors. This makes the development of PDE4B subtype selective inhibitors a desirable research goal. To achieve this goal, ligand based pharmacophore modeling approach is employed. Separate pharmacophore hypotheses for PDE4B and PDE4D inhibitors were generated using HypoGen algorithm and 106 PDE4 inhibitors from literature having thiopyrano [3,2-d] Pyrimidines, 2-arylpyrimidines, and triazines skeleton. Suitable training and test sets were created using the molecules as per the guidelines available for HypoGen program. Training set was used for hypothesis development while test set was used for validation purpose. Fisher validation was also used to test the significance of the developed hypothesis. The validated pharmacophore hypotheses for PDE4B and PDE4D inhibitors were used in sequential virtual screening of zinc database of drug like molecules to identify selective PDE4B inhibitors. The hits were screened for their estimated activity and fit value. The top hit was subjected to docking into the active sites of PDE4B and PDE4D to confirm its selectivity for PDE4B. The hits are proposed to be evaluated further using in-vitro assays. PMID:29201082
Combinatorial Methodology for Screening Selectivity in Polymeric Pervaporation Membranes.
Godbole, Rutvik V; Ma, Lan; Doerfert, Michael D; Williams, Porsche; Hedden, Ronald C
2015-11-09
Combinatorial methodology is described for rapid screening of selectivity in polymeric pervaporation membrane materials for alcohol-water separations. The screening technique is demonstrated for ethanol-water separation using a model polyacrylate system. The materials studied are cross-linked random copolymers of a hydrophobic comonomer (n-butyl acrylate, B) and a hydrophilic comonomer (2-hydroxyethyl acrylate, H). A matrix of materials is prepared that has orthogonal variations in two key variables, H:B ratio and cross-linker concentration. For mixtures of ethanol and water, equilibrium selectivities and distribution coefficients are obtained by combining swelling measurements with high-throughput HPLC analysis. Based on the screening results, two copolymers are selected for further study as pervaporation membranes to quantify permeability selectivity and the flux of ethanol. The screening methodology described has good potential to accelerate the search for new membrane materials, as it is adaptable to a broad range of polymer chemistries.
Phelan-Emrick, Darcy F.; Pollack, Craig E.; Markakis, Diane; Wenzel, Jennifer; Ahmed, Saifuddin; Garza, Mary A.; Shapiro, Gary R.; Bone, Lee R.; Johnson, Lawrence B.; Ford, Jean G.
2015-01-01
Purpose In recent years, colorectal cancer (CRC) screening rates have increased steadily in the USA, though racial and ethnic disparities persist. In a community-based randomized controlled trial, we investigated the effect of patient navigation on increasing CRC screening adherence among older African Americans. Methods Participants in the Cancer Prevention and Treatment Demonstration were randomized to either the control group, receiving only printed educational materials (PEM), or the intervention arm where they were assigned a patient navigator in addition to PEM. Navigators assisted participants with identifying and overcoming screening barriers. Logistic regression analyses were used to assess the effect of patient navigation on CRC screening adherence. Up-to-date with screening was defined as self-reported receipt of colonoscopy/sigmoidoscopy in the previous 10 years or fecal occult blood testing (FOBT) in the year prior to the exit interview. Results Compared with controls, the intervention group was more likely to report being up-to-date with CRC screening at the exit interview (OR 1.55, 95 % CI 1.07–2.23), after adjusting for select demographics. When examining the screening modalities separately, the patient navigator increased screening for colonoscopy/sigmoidoscopy (OR 1.53, 95 % CI 1.07–2.19), but not FOBT screening. Analyses of moderation revealed stronger effects of navigation among participants 65–69 years and those with an adequate health literacy level. Conclusions In a population of older African Americans adults, patient navigation was effective in increasing the likelihood of CRC screening. However, more intensive navigation may be necessary for adults over 70 years and individuals with low literacy levels. PMID:25516073
Horne, Hisani N; Phelan-Emrick, Darcy F; Pollack, Craig E; Markakis, Diane; Wenzel, Jennifer; Ahmed, Saifuddin; Garza, Mary A; Shapiro, Gary R; Bone, Lee R; Johnson, Lawrence B; Ford, Jean G
2015-02-01
In recent years, colorectal cancer (CRC) screening rates have increased steadily in the USA, though racial and ethnic disparities persist. In a community-based randomized controlled trial, we investigated the effect of patient navigation on increasing CRC screening adherence among older African Americans. Participants in the Cancer Prevention and Treatment Demonstration were randomized to either the control group, receiving only printed educational materials (PEM), or the intervention arm where they were assigned a patient navigator in addition to PEM. Navigators assisted participants with identifying and overcoming screening barriers. Logistic regression analyses were used to assess the effect of patient navigation on CRC screening adherence. Up-to-date with screening was defined as self-reported receipt of colonoscopy/sigmoidoscopy in the previous 10 years or fecal occult blood testing (FOBT) in the year prior to the exit interview. Compared with controls, the intervention group was more likely to report being up-to-date with CRC screening at the exit interview (OR 1.55, 95 % CI 1.07-2.23), after adjusting for select demographics. When examining the screening modalities separately, the patient navigator increased screening for colonoscopy/sigmoidoscopy (OR 1.53, 95 % CI 1.07-2.19), but not FOBT screening. Analyses of moderation revealed stronger effects of navigation among participants 65-69 years and those with an adequate health literacy level. In a population of older African Americans adults, patient navigation was effective in increasing the likelihood of CRC screening. However, more intensive navigation may be necessary for adults over 70 years and individuals with low literacy levels.
Wada, Takahito; Shimbo, Hiroko; Osaka, Hitoshi
2012-08-01
Cerebral creatine deficiency syndromes (CCDS) are caused by genetic defects in L-arginine:glycine amidinotransferase, guanidinoacetate methyltransferase or creatine transporter 1. CCDS are characterized by abnormal concentrations of urinary creatine (CR), guanidinoacetic acid (GA), or creatinine (CN). In this study, we describe a simple HPLC method to determine the concentrations of CR, GA, and CN using a weak-acid ion chromatography column with a UV detector without any derivatization. CR, GA, and CN were separated clearly with the retention times (mean ± SD, n = 3) of 5.54 ± 0.0035 min for CR, 6.41 ± 0.0079 min for GA, and 13.53 ± 0.046 min for CN. This new method should provide a simple screening test for the diagnosis of CCDS.
Krosshaug, Tron; Steffen, Kathrin; Kristianslund, Eirik; Nilstad, Agnethe; Mok, Kam-Ming; Myklebust, Grethe; Andersen, Thor Einar; Holme, Ingar; Engebretsen, Lars; Bahr, Roald
2016-04-01
The evidence linking knee kinematics and kinetics during a vertical drop jump (VDJ) to anterior cruciate ligament (ACL) injury risk is restricted to a single small sample. Still, the VDJ test continues to be advocated for clinical screening purposes. To test whether 5 selected kinematic and kinetic variables were associated with future ACL injuries in a large cohort of Norwegian female elite soccer and handball players. Furthermore, we wanted to assess whether the VDJ test can be recommended as a screening test to identify players with increased risk. Cohort study; Level of evidence, 2. Elite female soccer and handball players participated in preseason screening tests from 2007 through 2014. The tests included marker-based 3-dimensional motion analysis of a drop-jump landing. We followed a predefined statistical protocol in which we included the following candidate risk factors in 5 separate logistic regression analyses, with new ACL injury as the outcome: (1) knee valgus angle at initial contact, (2) peak knee abduction moment, (3) peak knee flexion angle, (4) peak vertical ground-reaction force, and (5) medial knee displacement. A total of 782 players were tested (age, 21 ± 4 years; height, 170 ± 7 cm; body mass, 67 ± 8 kg), of which 710 were included in the analyses. We registered 42 new noncontact ACL injuries, including 12 in previously ACL-injured players. Previous ACL injury (relative risk, 3.8; 95% CI, 2.1-7.1) and medial knee displacement (odds ratio, 1.40; 95% CI, 1.12-1.74 per 1-SD change) were associated with increased risk for injury. However, among the 643 players without previous injury, we found no association with medial knee displacement. A receiver operating characteristic curve analysis of medial knee displacement showed an area under the curve of 0.6, indicating a poor-to-failed combined sensitivity and specificity of the test, even when including previously injured players. Of the 5 risk factors considered, medial knee displacement was the only factor associated with increased risk for ACL. However, receiver operating characteristic curve analysis indicated a poor combined sensitivity and specificity when medial knee displacement was used as a screening test for predicting ACL injury. For players with no previous injury, none of the VDJ variables were associated with increased injury risk. VDJ tests cannot predict ACL injuries in female elite soccer and handball players. © 2016 The Author(s).
Zeman, Herbert D.
1994-01-01
A scintillator screen for an X-ray system includes a substrate of low-Z material and bodies of a high-Z material embedded within the substrate. By preselecting the size of the bodies embedded within the substrate, the spacial separation of the bodies and the thickness of the screen, the sensitivity of the screen to X-rays within a predetermined energy range can be predicted.
Hanafi, Rasha Sayed; Lämmerhofer, Michael
2018-01-26
Quality-by-Design approach for enantioselective HPLC method development surpasses Quality-by-Testing in offering the optimal separation conditions with the least number of experiments and in its ability to describe the method's Design Space visually which helps to determine enantiorecognition to a significant extent. Although some schemes exist for enantiomeric separations on Cinchona-based zwitterionic stationary phases, the exact design space and the weights by which each of the chromatographic parameters influences the separation have not yet been statistically studied. In the current work, a screening design followed by a Response Surface Methodology optimization design were adopted for enantioseparation optimization of 3 model drugs namely the acidic Fmoc leucine, the amphoteric tryptophan and the basic salbutamol. The screening design proved that the acid/base additives are of utmost importance for the 3 chiral drugs, and that among 3 different pairs of acids and bases, acetic acid and diethylamine is the couple able to provide acceptable resolution at variable conditions. Visualization of the response surface of the retention factor, separation factor and resolution helped describe accurately the magnitude by which each chromatographic factor (% MeOH, concentration and ratio of acid base modifiers) affects the separation while interacting with other parameters. The global optima compromising highest enantioresolution with the least run time for the 3 chiral model drugs varied extremely, where it was best to set low % methanol with equal ratio of acid-base modifiers for the acidic drug, very high % methanol and 10-fold higher concentration of the acid for the amphoteric drug while 20 folds of the base modifier with moderate %methanol were needed for the basic drug. Considering the selected drugs as models for many series of structurally related compounds, the design space defined and the optimum conditions computed are the key for method development on cinchona-based chiral stationary phases. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Acaba, K. J. C.; Cinco, L. D.; Melchor, J. N.
2016-03-01
Daily QC tests performed on screen film mammography (SFM) equipment are essential to ensure that both SFM unit and film processor are working in a consistent manner. The Breast Imaging Unit of USTH-Benavides Cancer Institute has been conducting QC following the test protocols in the IAEA Human Health Series No.2 manual. However, the availability of Leeds breast phantom (CRP E13039) in the facility made the task easier. Instead of carrying out separate tests on AEC constancy and light sensitometry, only one exposure of the phantom is done to accomplish the two tests. It was observed that measurements made on mAs output and optical densities (ODs) using the Leeds TOR (MAX) phantom are comparable with that obtained from the usual conduct of tests, taking into account the attenuation characteristic of the phantom. Image quality parameters such as low contrast and high contrast details were also evaluated from the phantom image. The authors recognize the usefulness of the phantom in determining technical factors that will help improve detection of smallest pathological details on breast images. The phantom is also convenient for daily QC monitoring and economical since less number of films is expended.
Cai, Shuangqi; Chen, Yiqiang; Song, Dezhi; Kong, Jinliang; Wu, Yanbin; Lu, Huasong
2016-11-01
The aim of the present study was to evaluate the imipenem-resistant mechanism via the outer membrane protein (OMP) OprD2 and metal β-lactamase expression in the cell wall of Pseudomonas aeruginosa . The Pseudomonas aeruginosa was clinically separated and validated by VITEK-2 full-automatic bacteria analyzer. Drug resistance, sensitive antibiotics and minimum inhibitory concentration (MIC) were tested using the drug sensitivity analysis system. The phenotype positive strains of MBL genes were screened using the Kirby-Bauer diffusion method by adding metal ion-chelating agent EDTA on the imipenem susceptibility paper. IMP-1, VIM-1 and SPM metaloenzyme genes were tested by polymerase chain reaction (PCR)-telomeric repeat amplification protocol (TRAP). The OMP OprD2 genes were tested by PCR-TRAP, and the protein expression was tested using western blot analysis. The location of OMP OprD2 was confirmed using the sodium salicylate inhibition test. The results showed that 80 portions (40%) of MBL-positive strains were screened out of 200 specimens. Imipenem-resistant Pseudomonas aeruginosa (IRPA) and MIC values were significantly higher than quality control bacteria and control bacteria (P<0.05). A total of 35 cases with IMP-1 positive, 20 with VIM-1 positive, 16 with SPM positive, 5 with 2 positive genes and 4 with 3 positive genes were screened among MBL positive strains. A total of 150 portions (75%) of OprD2 deficiencies were screened from 200 specimens. The standard strains and sensitive strains showed OprD2 protein bands at 45 kDa while no OprD2 protein bands appeared in OprD2 deficiency strains. It was in accordance with gene detection. In conclusion, OMP OprD2 deficiency and MBL phenotype positivity may be important mechanisms of IRPA.
Palma, Anton M; Rabkin, Miriam; Simelane, Samkelo; Gachuhi, Averie B; McNairy, Margaret L; Nuwagaba-Biribonwoha, Harriet; Bongomin, Pido; Okello, Velephi N; Bitchong, Raymond A; El-Sadr, Wafaa M
2018-03-01
Screening of modifiable cardiovascular disease (CVD) risk factors is recommended but not routinely provided for HIV-infected patients, especially in low-resource settings. Potential concerns include limited staff time and low patient acceptability, but little empirical data exists. As part of a pilot study of screening in a large urban HIV clinic in Swaziland, we conducted a time-motion study to assess the impact of screening on patient flow and HIV service delivery and exit interviews to assess patient acceptability. A convenience sample of patients ≥40 years of age attending routine HIV clinic visits was screened for hypertension, diabetes, hyperlipidemia and tobacco smoking. We observed HIV visits with and without screening and measured time spent on HIV and CVD risk factor screening activities. We compared screened and unscreened patients on total visit time and time spent receiving HIV services using Wilcoxon rank-sum tests. A separate convenience sample of screened patients participated in exit interviews to assess their satisfaction with screening. We observed 172 patient visits (122 with CVD risk factor screening and 50 without). Screening increased total visit time from a median (range) of 4 minutes (2 to 11) to 15 minutes (9 to 30) (p < 0.01). Time spent on HIV care was not affected: 4 (2 to 10) versus 4 (2 to 11) (p = 0.57). We recruited 126 patients for exit interviews, all of whom indicated that they would recommend screening to others. Provision of CVD risk factor screening more than tripled the length of routine HIV clinic visits but did not reduce the time spent on HIV services. Programme managers need to take longer visit duration into account in order to effectively integrate CVD risk factor screening and counselling into HIV programmes. © 2018 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.
Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin
2018-05-28
To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Santos-Zea, Liliana; Fajardo-Ramírez, Oscar R; Romo-López, Irasema; Gutiérrez-Uribe, Janet A
2016-03-01
Separation of potentially bioactive components from foods and plant extracts is one of the main challenges for their study. Centrifugal partition chromatography has been a successful technique for the screening and identification of molecules with bioactive potential, such as steroidal saponins. Agave is a source of steroidal saponins with anticancer potential, though the activity of these compounds in concentrated agave sap has not been yet explored. In this study, fast centrifugal partition chromatography (FCPC) was used coupled with in vitro tests on HT-29 cells as a screening procedure to identify apoptotic saponins from an acetonic extract of concentrated agave sap. The three most bioactive fractions obtained by FCPC at partition coefficients between 0.23 and 0.4 contained steroidal saponins, predominantly magueyoside b. Flow cytometry analysis determined that the fraction rich in kammogenin and manogenin glycosides induced apoptosis, but when gentrogenin and hecogenin glycosides were also found in the fraction, a necrotic effect was observed. In conclusion, this study provides the evidence that steroidal saponins in concentrated agave sap were potential inductors of apoptosis and that it was possible to separate them using fast centrifugal partition chromatography.
Disparities in cancer screening in individuals with a family history of breast or colorectal cancer.
Ponce, Ninez A; Tsui, Jennifer; Knight, Sara J; Afable-Munsuz, Aimee; Ladabaum, Uri; Hiatt, Robert A; Haas, Jennifer S
2012-03-15
Understanding racial/ethnic disparities in cancer screening by family history risk could identify critical opportunities for patient and provider interventions tailored to specific racial/ethnic groups. The authors evaluated whether breast cancer (BC) and colorectal cancer (CRC) disparities varied by family history risk using a large, multiethnic population-based survey. By using the 2005 California Health Interview Survey, BC and CRC screening were evaluated separately with weighted multivariate regression analyses, and stratified by family history risk. Screening was defined for BC as mammogram within the past 2 years for women aged 40 to 64 years; for CRC, screening was defined as annual fecal occult blood test, sigmoidoscopy within the past 5 years, or colonoscopy within the past 10 years for adults aged 50 to 64 years. The authors found no significant BC screening disparities by race/ethnicity or income in the family history risk groups. Racial/ethnic disparities were more evident in CRC screening, and the Latino-white gap widened among individuals with family history risk. Among adults with a family history for CRC, the magnitude of the Latino-white difference in CRC screening (odds ratio [OR], 0.28; 95% confidence interval [CI], 0.11-0.60) was more substantial than that for individuals with no family history (OR, 0.74; 95% CI, 0.59-0.92). Knowledge of their family history widened the Latino-white gap in CRC screening among adults. More aggressive interventions that enhance the communication between Latinos and their physicians about family history and cancer risk could reduce the substantial Latino-white screening disparity in Latinos most susceptible to CRC. Copyright © 2011 American Cancer Society.
Takashima, Eizo; Williams, Marni; Eiglmeier, Karin; Pain, Adrien; Guelbeogo, Wamdaogo M.; Gneme, Awa; Brito-Fravallo, Emma; Holm, Inge; Lavazec, Catherine; Sagnon, N’Fale; Baxter, Richard H.; Riehle, Michelle M.; Vernick, Kenneth D.
2015-01-01
Nucleotide variation patterns across species are shaped by the processes of natural selection, including exposure to environmental pathogens. We examined patterns of genetic variation in two sister species, Anopheles gambiae and Anopheles coluzzii, both efficient natural vectors of human malaria in West Africa. We used the differentiation signature displayed by a known coordinate selective sweep of immune genes APL1 and TEP1 in A. coluzzii to design a population genetic screen trained on the sweep, classified a panel of 26 potential immune genes for concordance with the signature, and functionally tested their immune phenotypes. The screen results were strongly predictive for genes with protective immune phenotypes: genes meeting the screen criteria were significantly more likely to display a functional phenotype against malaria infection than genes not meeting the criteria (p = 0.0005). Thus, an evolution-based screen can efficiently prioritize candidate genes for labor-intensive downstream functional testing, and safely allow the elimination of genes not meeting the screen criteria. The suite of immune genes with characteristics similar to the APL1-TEP1 selective sweep appears to be more widespread in the A. coluzzii genome than previously recognized. The immune gene differentiation may be a consequence of adaptation of A. coluzzii to new pathogens encountered in its niche expansion during the separation from A. gambiae, although the role, if any of natural selection by Plasmodium is unknown. Application of the screen allowed identification of new functional immune factors, and assignment of new functions to known factors. We describe biochemical binding interactions between immune proteins that underlie functional activity for malaria infection, which highlights the interplay between pathogen specificity and the structure of immune complexes. We also find that most malaria-protective immune factors display phenotypes for either human or rodent malaria, with broad specificity a rarity. PMID:26633695
Database Dictionary for Ethiopian National Ground-Water DAtabase (ENGDA) Data Fields
Kuniansky, Eve L.; Litke, David W.; Tucci, Patrick
2007-01-01
Introduction This document describes the data fields that are used for both field forms and the Ethiopian National Ground-water Database (ENGDA) tables associated with information stored about production wells, springs, test holes, test wells, and water level or water-quality observation wells. Several different words are used in this database dictionary and in the ENGDA database to describe a narrow shaft constructed in the ground. The most general term is borehole, which is applicable to any type of hole. A well is a borehole specifically constructed to extract water from the ground; however, for this data dictionary and for the ENGDA database, the words well and borehole are used interchangeably. A production well is defined as any well used for water supply and includes hand-dug wells, small-diameter bored wells equipped with hand pumps, or large-diameter bored wells equipped with large-capacity motorized pumps. Test holes are borings made to collect information about the subsurface with continuous core or non-continuous core and/or where geophysical logs are collected. Test holes are not converted into wells. A test well is a well constructed for hydraulic testing of an aquifer in order to plan a larger ground-water production system. A water-level or water-quality observation well is a well that is used to collect information about an aquifer and not used for water supply. A spring is any naturally flowing, local, ground-water discharge site. The database dictionary is designed to help define all fields on both field data collection forms (provided in attachment 2 of this report) and for the ENGDA software screen entry forms (described in Litke, 2007). The data entered into each screen entry field are stored in relational database tables within the computer database. The organization of the database dictionary is designed based on field data collection and the field forms, because this is what the majority of people will use. After each field, however, the ENGDA database field name and relational database table is designated; along with the ENGDA screen entry form(s) and the ENGDA field form (attachment 2). The database dictionary is separated into sections. The first section, Basic Site Data Fields, describes the basic site information that is similar for all of the different types of sites. The remaining sections may be applicable for only one type of site; for example, the Well Drilling and Construction Data Fields and Lithologic Description Data Fields are applicable to boreholes and not to springs. Attachment 1 contains a table for conversion from English to metric units. Attachment 2 contains selected field forms used in conjunction with ENGDA. A separate document, 'Users Reference Manual for the Ethiopian National Ground-Water DAtabase (ENGDA),' by David W. Litke was developed as a users guide for the computer database and screen entry. This database dictionary serves as a reference for both the field forms and the computer database. Every effort has been made to have identical field names between the field forms and the screen entry forms in order to avoid confusion.
Mesa, Matthew G.; Rose, Brien P.; Copeland, Elizabeth S.
2012-01-01
Screens are installed at water diversion sites to reduce entrainment of fish. Recently, the Farmers Irrigation District (Oregon) developed a unique flat-plate screen (the “Farmers Screen”) that operates passively and may offer reduced installation and operating costs. To evaluate the effectiveness of this screen on fish, we conducted two separate field experiments. First, juvenile coho salmon Oncorhynchus kisutch were released over a working version of this screen under a range of inflows (0.02–0.42 m3/s) and diversion flows (0.02–0.34 m3/s) at different water depths. Mean approach velocities ranged from 0 to 5 cm/s and sweeping velocities ranged from 36 to 178 cm/s. Water depths over the screen surface ranged from 1 to 25 cm and were directly related to inflow. Passage of fish over the screen under these conditions did not severely injure them or cause delayed mortality, and no fish were observed becoming impinged on the screen surface. Second, juvenile coho salmon and steelhead O. mykiss were released at the upstream end of a 34-m flume and allowed to volitionally move downstream and pass over a 3.5-m section of the Farmers Screen to determine whether fish would refuse to pass over the screen after encountering its leading edge. For coho salmon, 75–95% of the fish passed over the screen within 5 min and 82–98% passed within 20 min, depending on hydraulic conditions. For steelhead, 47–90% of the fish passed over the screen within 5 min and 79–95% passed within 20 min. Our results indicate that when operated within its design criteria, the Farmers Screen provides safe and efficient downstream passage of juvenile salmonids under a variety of hydraulic conditions.
Zhang, Minmin; Zhao, Hengqiang; Zhao, Zhiguo; Yan, Huijiao; Lv, Ruimin; Cui, Li; Yuan, Jinpeng; Wang, Daijie; Geng, Yanling; Liu, Daicheng; Wang, Xiao
2016-06-01
We put forward an efficient strategy based on bioassay guidance for the rapid screening, identification, and purification of the neuraminidase inhibitors from traditional Chinese medicines, and apply to the discovery of anti-influenza components from Lithospermiun erythrorhizon Sieb.et Zucc. Ultrafiltration with high-performance liquid chromatography and electrospray ionization time-of-flight mass spectrometry was employed for the rapid screening and preliminarily identification of anti-influenza components from Zicao. Semipreparative high-performance liquid chromatography was used for the rapid separation and purification of the target compounds. NMR spectroscopy, mass spectrometry, and UV spectroscopy were used for further structural identification, and the activity of the compounds was verified by in vitro assay. Five compounds were found to have neuraminidase inhibitory activity by this method. Subsequently, the five compounds were separated by semipreparative high-performance liquid chromatography with the purity over 98% for all of them by high-performance liquid chromatography test. Combined with the NMR spectroscopy, mass spectrometry, and UV spectroscopy data, they were identified as alkannin, acetylalkannin, isobutyrylalkannin, β,β-dimethylacryloylalkannin and isovalerylalkannin. The in vitro assay showed that all five compounds had good neuraminidase inhibitory activities. These results suggested that the method is highly efficient, and it can provide platform and methodology supports for the rapid discovery of anti-influenza active ingredients from complex Chinese herbal medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...
Wei, Xuetuan; Luo, Mingfang; Xie, Yuchun; Yang, Liangrong; Li, Haojian; Xu, Lin; Liu, Huizhou
2012-12-01
This study presents a novel and integrated preparation technology for nattokinase functional food, including strain screening, fermentation, separation, and encapsulation. To rapidly screen a nattokinase-productive strain, PCR-based screening method was combined with fibrinolytic activity-based method, and a high productive strain, Bacillus subtilis LSSE-22, was isolated from Chinese soybean paste. Reduction of poly-γ-glutamic acid (γ-PGA) concentration may contribute to separation of nattokinase and reduction of late-onset anaphylaxis risk. Chickpeas were confirmed as the favorable substrate for enhancement of nattokinase production and reduction of γ-PGA yield. Using cracked chickpeas, the nattokinase activity reached 356.25 ± 17.18 FU/g (dry weight), which is much higher than previous reports. To further reduce γ-PGA concentration, ethanol fractional extraction and precipitation were applied for separation of nattokinase. By extraction with 50 % and precipitation with 75 % ethanol solution, 4,000.58 ± 192.98 FU/g of nattokinase powders were obtained, and the activity recovery reached 89 ± 1 %, while γ-PGA recovery was reduced to 21 ± 2 %. To improve the nattokinase stability at acidic pH condition, the nattokinase powders were encapsulated, and then coated with methacrylic acid-ethyl acrylate copolymer. After encapsulation, the nattokinase was protected from being denatured under various acid conditions, and pH-responsible controlled release at simulated intestinal fluid was realized.
Deconinck, E; Djiogo, C A Sokeng; Bothy, J L; Courselle, P
2017-08-05
The identification of a specific toxic or regulated plant in herbal preparations or plant food supplements is a real challenge, since they are often powdered, mixed with other herbal or synthetic powders and compressed into tablets or capsules. The classical identification approaches based on micro- and macroscopy are therefore not possible anymore. In this paper infrared spectroscopy, combined with attenuated total reflectance was evaluated for the screening of plant based preparations for nine specific plants (five regulated and four common plants for herbal supplements). IR and NIR spectra were recorded for a series of self-made triturations of the targeted plants. After pretreatment of the spectral data chemometric classification techniques were applied to both data sets (IR and NIR) separately and the combination of both. The results show that the screening of herbal preparations or plant food supplements for specific plants, using infrared spectroscopy, is feasible. The best model was obtained with the Mid-IR data, using SIMCA as modelling technique. During validation of the model, using an external test set, 21 of 25 were correctly classified and six of the nine targeted plants showed no misclassifications for the selected test set. For the other three a success rate of 50% was obtained. Mid-IR combined with SIMCA can therefore be applied as a first step in the screening of unknown samples, before applying more sophisticated fingerprint approaches or identification tests described in several national and international pharmacopoeia. As a proof of concept five real suspicious samples were successfully screened for the targeted regulated plants. Copyright © 2017 Elsevier B.V. All rights reserved.
Shamonki, Mousa I; Jin, Helen; Haimowitz, Zachary; Liu, Lian
2016-11-01
To assess whether preimplantation genetic screening (PGS) is possible by testing for free embryonic DNA in spent IVF media from embryos undergoing trophectoderm biopsy. Prospective cohort analysis. Academic fertility center. Seven patients undergoing IVF and 57 embryos undergoing trophectoderm biopsy for PGS. On day 3 of development, each embryo was placed in a separate media droplet. All biopsied embryos received a PGS result by array comparative genomic hybridization. Preimplantation genetic screening was performed on amplified DNA extracted from media and results were compared with PGS results for the corresponding biopsy. [1] Presence of DNA in spent IVF culture media. [2] Correlation between genetic screening result from spent media and corresponding biopsy. Fifty-five samples had detectable DNA ranging from 2-642 ng/μL after a 2-hour amplification. Six samples with the highest DNA levels underwent PGS, rendering one result with a derivative log ratio SD (DLRSD) of <0.85 (a quality control metric of oligonucleotide array comparative genomic hybridization). The fluid sample and trophectoderm results were identical demonstrating (45XY, -13). Three samples were reamplified 1 hour later and tested showing improving DLRSD. One of the three samples with a DLRSD of 0.85 demonstrated (46XY), consistent with the biopsy. Overnight DNA amplification showed DNA in all samples. We demonstrate two novel findings: the presence of free embryonic DNA in spent media and a result that is consistent with trophectoderm biopsy. Improvements in DNA collection, amplification, and testing may allow for PGS without biopsy in the future. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Whitley, Elizabeth M; Raich, Peter C; Dudley, Donald J; Freund, Karen M; Paskett, Electra D; Patierno, Steven R; Simon, Melissa; Warren-Mears, Victoria; Snyder, Frederick R
2017-01-01
Whether patient navigation improves outcomes for patients with comorbidities is unknown. The aims of this study were to determine the effect of comorbidities on the time to diagnostic resolution after an abnormal cancer screening test and to examine whether patient navigation improves the timeliness and likelihood of diagnostic resolution for patients with comorbidities in comparison with no navigation. A secondary analysis of comorbidity data collected by Patient Navigation Research Program sites using the Charlson Comorbidity Index (CCI) was conducted. The participants were 6,349 patients with abnormal breast, cervical, colon, or prostate cancer screening tests between 2007 and 2011. The intervention was patient navigation or usual care. The CCI data were highly skewed across projects and cancer sites, and the CCI scores were categorized as 0 (CCI score of 0 or no comorbidities identified; 76% of cases); 1 (CCI score of 1; 16% of cases), or 2 (CCI score ≥ 2; 8% of cases). Separate adjusted hazard ratios for each site and cancer type were obtained, and then they were pooled with a meta-analysis random effects methodology. Patients with a CCI score ≥ 2 had delayed diagnostic resolution after an abnormal cancer screening test in comparison with those with no comorbidities. Patient navigation reduced delays in diagnostic resolution, with the greatest benefits seen for those with a CCI score ≥ 2. Persons with a CCI score ≥ 2 experienced significant delays in timely diagnostic care in comparison with patients without comorbidities. Patient navigation was effective in reducing delays in diagnostic resolution among those with CCI scores > 1. Cancer 2017;123:312-318. © 2016 American Cancer Society. © 2016 American Cancer Society.
NASA Astrophysics Data System (ADS)
Burrage, Clare; Sakstein, Jeremy
2018-03-01
Theories of modified gravity, where light scalars with non-trivial self-interactions and non-minimal couplings to matter—chameleon and symmetron theories—dynamically suppress deviations from general relativity in the solar system. On other scales, the environmental nature of the screening means that such scalars may be relevant. The highly-nonlinear nature of screening mechanisms means that they evade classical fifth-force searches, and there has been an intense effort towards designing new and novel tests to probe them, both in the laboratory and using astrophysical objects, and by reinterpreting existing datasets. The results of these searches are often presented using different parametrizations, which can make it difficult to compare constraints coming from different probes. The purpose of this review is to summarize the present state-of-the-art searches for screened scalars coupled to matter, and to translate the current bounds into a single parametrization to survey the state of the models. Presently, commonly studied chameleon models are well-constrained but less commonly studied models have large regions of parameter space that are still viable. Symmetron models are constrained well by astrophysical and laboratory tests, but there is a desert separating the two scales where the model is unconstrained. The coupling of chameleons to photons is tightly constrained but the symmetron coupling has yet to be explored. We also summarize the current bounds on f( R) models that exhibit the chameleon mechanism (Hu and Sawicki models). The simplest of these are well constrained by astrophysical probes, but there are currently few reported bounds for theories with higher powers of R. The review ends by discussing the future prospects for constraining screened modified gravity models further using upcoming and planned experiments.
Systematic Exploitation of Multiple Receptor Conformations for Virtual Ligand Screening
Bottegoni, Giovanni; Rocchia, Walter; Rueda, Manuel; Abagyan, Ruben; Cavalli, Andrea
2011-01-01
The role of virtual ligand screening in modern drug discovery is to mine large chemical collections and to prioritize for experimental testing a comparatively small and diverse set of compounds with expected activity against a target. Several studies have pointed out that the performance of virtual ligand screening can be improved by taking into account receptor flexibility. Here, we systematically assess how multiple crystallographic receptor conformations, a powerful way of discretely representing protein plasticity, can be exploited in screening protocols to separate binders from non-binders. Our analyses encompass 36 targets of pharmaceutical relevance and are based on actual molecules with reported activity against those targets. The results suggest that an ensemble receptor-based protocol displays a stronger discriminating power between active and inactive molecules as compared to its standard single rigid receptor counterpart. Moreover, such a protocol can be engineered not only to enrich a higher number of active compounds, but also to enhance their chemical diversity. Finally, some clear indications can be gathered on how to select a subset of receptor conformations that is most likely to provide the best performance in a real life scenario. PMID:21625529
Benmohamed, Radhia; Arvanites, Anthony C; Kim, Jinho; Ferrante, Robert J; Silverman, Richard B; Morimoto, Richard I; Kirsch, Donald R
2011-03-01
The underlying cause of amyotrophic lateral sclerosis (ALS), a progressive neurodegenerative disorder, remains unknown. However, there is strong evidence that one pathophysiological mechanism, toxic protein misfolding and/or aggregation, may trigger motor neuron dysfunction and loss. Since the clinical and pathological features of sporadic and familial ALS are indistinguishable, all forms of the disease may be better understood and ultimately treated by studying pathogenesis and therapy in models expressing mutant forms of SOD1. We developed a cellular model in which cell death depended on the expression of G93A-SOD1, a mutant form of superoxide dismutase found in familial ALS patients that produces toxic protein aggregates. This cellular model was optimized for high throughput screening to identify protective compounds from a >50,000 member chemical library. Three novel chemical scaffolds were selected for further study following screen implementation, counter-screening and secondary testing, including studies with purchased analogs. All three scaffolds blocked SOD1 aggregation in high content screening assays and data on the optimization and further characterization of these compounds will be reported separately. These data suggest that optimization of these chemicals scaffolds may produce therapeutic candidates for ALS patients.
Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C
2007-01-01
After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.
Weaver, Abigail A; Reiser, Hannah; Barstis, Toni; Benvenuti, Michael; Ghosh, Debarati; Hunckler, Michael; Joy, Brittney; Koenig, Leah; Raddell, Kellie; Lieberman, Marya
2013-07-02
Reports of low-quality pharmaceuticals have been on the rise in the past decade, with the greatest prevalence of substandard medicines in developing countries, where lapses in manufacturing quality control or breaches in the supply chain allow substandard medicines to reach the marketplace. Here, we describe inexpensive test cards for fast field screening of pharmaceutical dosage forms containing beta lactam antibiotics or combinations of the four first-line antituberculosis (TB) drugs. The devices detect the active pharmaceutical ingredients (APIs) ampicillin, amoxicillin, rifampicin, isoniazid, ethambutol, and pyrazinamide and also screen for substitute pharmaceuticals, such as acetaminophen and chloroquine that may be found in counterfeit pharmaceuticals. The tests can detect binders and fillers such as chalk, talc, and starch not revealed by traditional chromatographic methods. These paper devices contain 12 lanes, separated by hydrophobic barriers, with different reagents deposited in the lanes. The user rubs some of the solid pharmaceutical across the lanes and dips the edge of the paper into water. As water climbs up the lanes by capillary action, it triggers a library of different chemical tests and a timer to indicate when the tests are completed. The reactions in each lane generate colors to form a "color bar code" which can be analyzed visually by comparison with standard outcomes. Although quantification of the APIs is poor compared with conventional analytical methods, the sensitivity and selectivity for the analytes is high enough to pick out suspicious formulations containing no API or a substitute API as well as formulations containing APIs that have been "cut" with inactive ingredients.
Weaver, Abigail A.; Reiser, Hannah; Barstis, Toni; Benvenuti, Michael; Ghosh, Debarati; Hunckler, Michael; Joy, Brittney; Koenig, Leah; Raddell, Kellie; Lieberman, Marya
2013-01-01
Reports of low quality pharmaceuticals have been on the rise in the last decade with the greatest prevalence of substandard medicines in developing countries, where lapses in manufacturing quality control or breaches in the supply chain allow substandard medicines to reach the marketplace. Here, we describe inexpensive test cards for fast field screening of pharmaceutical dosage forms containing beta lactam antibiotics or combinations of the four first-line antituberculosis (TB) drugs. The devices detect the active pharmaceutical ingredients (APIs) ampicillin, amoxicillin, rifampicin, isoniazid, ethambutol, and pyrazinamide, and also screen for substitute pharmaceuticals such as acetaminophen and chloroquine that may be found in counterfeit pharmaceuticals. The tests can detect binders and fillers like chalk, talc, and starch not revealed by traditional chromatographic methods. These paper devices contain twelve lanes, separated by hydrophobic barriers, with different reagents deposited in the lanes. The user rubs some of the solid pharmaceutical across the lanes and dips the edge of the paper into water. As water climbs up the lanes by capillary action, it triggers a library of different chemical tests and a timer to indicate when the tests are completed. The reactions in each lane generate colors to form a “color bar code” which can be analyzed visually by comparison to standard outcomes. While quantification of the APIs is poor compared to conventional analytical methods, the sensitivity and selectivity for the analytes is high enough to pick out suspicious formulations containing no API or a substitute API, as well as formulations containing APIs that have been “cut” with inactive ingredients. PMID:23725012
Wang, Chunyan; Zhu, Hongbin; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2013-02-01
The quantitative analysis of amino acids (AAs) in single dry blood spot (DBS) samples is an important issue for metabolic diseases as a second-tier test in newborn screening. An analytical method for quantifying underivatized AAs in DBS was developed by using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The sample preparation in this method is simple and ion-pairing agent is not used in the mobile phase that could avoid ion suppression, which happens in mass spectrometry and avoids damage to the column. Through chromatographic separation, some isomeric compounds could be identified and quantified, which cannot be solved through only appropriate multiple reactions monitoring transitions by MS/MS. The concentrations of the different AAs were determined using non-deuterated internal standard. All calibration curves showed excellent linearity within test ranges. For most of the amino acids the accuracy of extraction recovery was between 85.3 and 115 %, and the precision of relative standard deviation was <7.0 %. The 35 AAs could be identified in DBS specimens by the developed LC-MS/MS method in 17-19 min, and eventually 24 AAs in DBS were quantified. The results of the present study prove that this method as a second-tier test in newborn screening for metabolic diseases could be performed by the quantification of free AAs in DBS using the LC-MS/MS method. The assay has advantages of high sensitive, specific, and inexpensive merits because non-deuterated internal standard and acetic acid instead of ion-pairing agent in mobile phase are used in this protocol.
Preparation of ionic membranes for zinc/bromine storage batteries
NASA Astrophysics Data System (ADS)
Assink, R. A.; Arnold, C., Jr.
Zinc/bromine flow batteries are being developed for vehicular and utility load leveling applications. During charge, an aqueous zinc bromide salt is electrolyzed to zinc metal and molecular bromine. During discharge, the zinc and bromine react to again form the zinc bromide salt. One serious disadvantage of the microporous separators presently used in the zinc/bromine battery is that modest amounts of bromine and negatively charged bromine moieties permeate through these materials and react with the zinc anode. This results in partial self-discharge of the battery and low coulombic efficiencies. Our approach to this problem is to impregnate the microporous separators with a soluble cationic polyelectrolyte. In laboratory screening tests a sulfonated polysulfone resin and fully fluorinated sulfonic acid polymer substantially reduced bromine permeation with only modest increases in the area resistance.
Metrology for Industry for use in the Manufacture of Grazing Incidence Beam Line Mirrors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Metz, James P.; Parks, Robert E.
2014-12-01
The goal of this SBIR was to determine the slope sensitivity of Specular Reflection Deflectometry (SRD) and whether shearing methods had the sensitivity to be able to separate errors in the test equipment from slope error in the unit under test (UUT), or mirror. After many variations of test parameters it does not appear that SRD yields results much better than 1 μ radian RMS independent of how much averaging is done. Of course, a single number slope sensitivity over the full range of spatial scales is not a very insightful number in the same sense as a single numbermore » phase or height RMS value in interferometry does not tell the full story. However, the 1 μ radian RMS number is meaningful when contrasted with a sensitivity goal of better than 0.1 μ radian RMS. Shearing is a time proven method of separating the errors in a measurement from the actual shape of a UUT. It is accomplished by taking multiple measurements while moving the UUT relative to the test instrument. This process makes it possible to separate the two errors sources but only to a sensitivity of about 1 μ radian RMS. Another aspect of our conclusions is that this limit probably holds largely independent of the spatial scale of the test equipment. In the proposal for this work it was suggested that a test screen the full size of the UUT could be used to determine the slopes on scales of maybe 0.01 to full scale of the UUT while smaller screens and shorter focal length lenses could be used to measure shorter, or smaller, patches of slope. What we failed to take into consideration was that as the scale of the test equipment got smaller so too did the optical lever arm on which the slope was calculated. Although we did not do a test with a shorter focal length lens over a smaller sample area it is hard to argue with the logic that the slope sensitivity will be about the same independent of the spatial scale of the measurement assuming the test equipment is similarly scaled. On a more positive note, SRD does appear to be a highly flexible, easy to implement, rather inexpensive test for free form optics that require a dynamic range that exceeds that of interferometry. These optics are quite often specified to have more relaxed slope errors, on the order of 1 μ radian RMS or greater. It would be shortsighted to not recognize the value of this test method in the bigger picture.« less
Pang, Hauchie; Cataldi, Mariel; Allseits, Emmanuelle; Ward-Peterson, Melissa; de la Vega, Pura Rodríguez; Castro, Grettel; Acuña, Juan Manuel
2017-01-01
Abstract Immigrant minorities regularly experience higher incidence and mortality rates of cancer. Frequently, a variety of social determinants create obstacles for those individuals to get the screenings they need. This is especially true for Haitian immigrants, a particularly vulnerable immigrant population in South Florida, who have been identified as having low cancer screening rates. While Haitian immigrants have some of the lowest cancer screening rates in the country, there is little existing literature that addresses barriers to cancer screenings among the population of Little Haiti in Miami-Dade County, Florida. The objective of this study was to evaluate the association between having a regular source of healthcare and adherence to recommended cancer screenings in the Little Haiti population of Miami. This secondary analysis utilized data collected from a random-sample, population-based household survey conducted from November 2011 to December 2012 among a geographic area approximating Little Haiti in Miami-Dade County, Florida. A total of 421 households identified as Haitian. The main exposure of interest was whether households possessed a regular source of care. Three separate outcomes were considered: adherence with colorectal cancer screening, mammogram adherence, and Pap smear adherence. Analysis was limited to households who met the age criteria for each outcome of interest. Bivariate associations were examined using the chi square test and Fisher exact test. Binary logistic regression was used to estimate unadjusted and adjusted odds ratios (ORs) with 95% confidence intervals (CIs). After adjusting for the head of household's education and household insurance status, households without a regular source of care were significantly less likely to adhere with colorectal cancer screening (OR = 0.33; 95% CI: 0.14–0.80) or mammograms (OR = 0.28; 95% CI: 0.11–0.75). Households with insurance coverage gaps were significantly less likely to adhere with mammograms (OR = 0.40; 95% CI: 0.17–0.97) or Pap smears (OR = 0.28; 95% CI: 0.13–0.58). Our study explored adherence with multiple cancer screenings. We found a strong association between possessing a regular source of care and adherence with colorectal cancer screening and mammogram adherence. Targeted approaches to improving access to regular care may improve adherence to cancer screening adherence among this unique immigrant population. PMID:28796056
Amperometric detector designs for capillary electrophoresis microchips.
Castaño-Alvarez, Mario; Fernández-Abedul, M Teresa; Costa-García, Agustín
2006-03-24
Electrochemical (EC) detection is a sensitive and miniaturisable detection mode for capillary electrophoresis (CE) microchips. Detection cell design is very important in order to ensure electrical isolation from the high separation voltage. Amperometric detectors with different designs have been developed for coupling EC detection to CE-microchips. Different working electrode alignment: in-channel or end-channel has been tested in conjunction with several materials: gold, platinum or carbon. The end-channel detector was based on a platinum or gold wire manually aligned at the exit of the separation channel. Thick- (screen-printed carbon electrode) and thin-film (sputtered gold film) electrodes have also been employed with this configuration, but with a different design that allowed the rapid replacement of the electrode. The in-channel detector was based on a gold film within the separation channel. A gold-based dual electrode detector, which combined for the first time in- and end-channel detection, has been also tested. These amperometric detectors have been evaluated in combination to poly(methylmethacrylate) (PMMA) and Topas (thermoplastic olefin polymer of amorphous structure) CE-microchips. Topas is a new and promising cyclic olefin copolymer with high chemical resistance. Relevant parameters of the polymer microchip separation such as precision, efficiency or resolution and amperometric detection were studied with the different detector designs using p-aminophenol and L-ascorbic acid as model analytes in Tris-based buffer pH 9.0.
Mohr, Peter G; Moody, Nicholas J G; Williams, Lynette M; Hoad, John; Cummins, David M; Davies, Kelly R; StJ Crane, Mark
2015-10-16
Viruses of the genus Megalocytivirus have not been detected in wild populations of fish in Australia but circulate in imported ornamental fish. In 2012, detection of a megalocytivirus in healthy platys Xiphophorus maculatus was reported from a farm in Australia during surveillance testing as part of a research project undertaken at the University of Sydney. Confirmatory testing of the original samples at the AAHL Fish Diseases Laboratory verified the presence of an infectious spleen and kidney necrosis virus (ISKNV)-like virus. Additional sampling at the positive farm confirmed the persistence of the virus in the platys, with 39 of 265 (14.7%) samples testing positive. Comparison of 3 separate gene regions of the virus with those of ISKNV confirmed the detection of a virus indistinguishable from ISKNV. Subsequently, ISKNV was also detected in a range of imported ornamental fish from several countries between 2013 and 2014, by screening with real-time PCR and confirmation by conventional PCR and sequence analysis. Accordingly, the current importation of live ornamental fish acts as a potential perpetual source for the establishment of ISKNV viruses within Australia. The testing of the farmed and imported ornamental fish verified the utility of the probe-based real-time PCR assay for screening of ornamental fish for Megalocytivirus.
Association of marital status and colorectal cancer screening participation in the USA.
El-Haddad, B; Dong, F; Kallail, K J; Hines, R B; Ablah, E
2015-05-01
In the USA, for both men and women, colorectal cancer (CRC) ranks third in incidence and second in mortality. Despite evidence that it decreases mortality, CRC screening in the USA remains under-utilized. Some European studies have suggested that marital status affects participation in CRC screening, but the effect of marital status on CRC screening participation in the USA is unknown. In this study, the aim was to compare CRC screening participation rates among married and unmarried couples, separated, widowed, never married and divorced adults living in the USA. This was a retrospective data analysis of the 2010 Behavioural Risk Factor Surveillance System survey. The population studied included 239,300 participants, aged 50-75 years, who completed the 2010 survey. Logistic regression analysis was conducted to assess the association between adherence with CRC screening guidelines and marital status while accounting for survey stratum/weight and covariates. Individuals who were divorced or separated, never married or widowed had decreased odds of adherence with CRC screening guidelines compared with individuals who were married and unmarried couples. In this study, individuals living in the USA who were married and unmarried couples had increased odds of undergoing CRC screening compared to individuals in other marital status groups. Public health interventions are needed to promote CRC screening participation in these other groups. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.
A simple biota removal algorithm for 35 GHz cloud radar measurements
NASA Astrophysics Data System (ADS)
Kalapureddy, Madhu Chandra R.; Sukanya, Patra; Das, Subrata K.; Deshpande, Sachin M.; Pandithurai, Govindan; Pazamany, Andrew L.; Ambuj K., Jha; Chakravarty, Kaustav; Kalekar, Prasad; Krishna Devisetty, Hari; Annam, Sreenivas
2018-03-01
Cloud radar reflectivity profiles can be an important measurement for the investigation of cloud vertical structure (CVS). However, extracting intended meteorological cloud content from the measurement often demands an effective technique or algorithm that can reduce error and observational uncertainties in the recorded data. In this work, a technique is proposed to identify and separate cloud and non-hydrometeor echoes using the radar Doppler spectral moments profile measurements. The point and volume target-based theoretical radar sensitivity curves are used for removing the receiver noise floor and identified radar echoes are scrutinized according to the signal decorrelation period. Here, it is hypothesized that cloud echoes are observed to be temporally more coherent and homogenous and have a longer correlation period than biota. That can be checked statistically using ˜ 4 s sliding mean and standard deviation value of reflectivity profiles. The above step helps in screen out clouds critically by filtering out the biota. The final important step strives for the retrieval of cloud height. The proposed algorithm potentially identifies cloud height solely through the systematic characterization of Z variability using the local atmospheric vertical structure knowledge besides to the theoretical, statistical and echo tracing tools. Thus, characterization of high-resolution cloud radar reflectivity profile measurements has been done with the theoretical echo sensitivity curves and observed echo statistics for the true cloud height tracking (TEST). TEST showed superior performance in screening out clouds and filtering out isolated insects. TEST constrained with polarimetric measurements was found to be more promising under high-density biota whereas TEST combined with linear depolarization ratio and spectral width perform potentially to filter out biota within the highly turbulent shallow cumulus clouds in the convective boundary layer (CBL). This TEST technique is promisingly simple in realization but powerful in performance due to the flexibility in constraining, identifying and filtering out the biota and screening out the true cloud content, especially the CBL clouds. Therefore, the TEST algorithm is superior for screening out the low-level clouds that are strongly linked to the rainmaking mechanism associated with the Indian Summer Monsoon region's CVS.
Performance of two hearing screening protocols in NICU in Shanghai.
Xu, Zheng-Min; Cheng, Wen-Xia; Yang, Xiao-Lin
2011-10-01
To study the sensitivity and specificity of targeted neonatal hearing screening for the single-session distortion product otoacoustic emissions (DPOAE) technique and the combined DPOAE/automated auditory brain-stem response (AABR) technique. 3000 high-risk newborns were studied at Children's Hospital of Fudan University. They were required to take two different screening procedures separately. The first procedure consisted of DPOAE alone and the second consisted of DPOAE combined with the AABR. Based upon the etiology in high-risk babies, they were divided into four groups. In group I there were 670 very-low-birth-weight (VLBW) newborns (1340 ears), and in group II there were 890 preterm babies (1780 ears). 850 babies (1700 ears) suffered from hyperbilirubinemia in group III, whereas 790 babies (1580 ears) with asphyxia were in group IV. The babies in groups II, III, and IV came from the neonatal intensive-care unit (NICU) of our hospital. The study protocols consisted of the DPOAE alone and DPOAE combined with AABR hearing screening at an age of less than 1 month, and a diagnostic stage at the age of 2 months. With single-session DPOAE screening, the referral rate (8% of the NICU babies), the false-positive rate (4.96%) and the false-negative rate (0.8%) were higher. The different etiologies in NICU babies had significantly different referral rates (F-test, p<0.01). A 4.46% referral rate of hyperbilirubinemi babies was much lower. The combined DPOAE/AABR screening technique revealed a referral rate of 5.03%, a false-positive rate of 2% and a false-negative rate of 0.06%. The false-positive rate was well below the suggested 3% of the American Academy of Pediatric. Comparisons of the referral rate, false-positive rate and false-negative rate of two hearing screening protocols (DPOAE alone and combined DPOAE/AABR) revealed significant differences (t-test, p<0.05, p<0.01, p<0.01). 91 infants (3.03% of the NICU babies) who failed the combined DPOAE/AABR screening were confirmed on hearing impairment. Of 22 babies who passed DPOAE screening but failed the AABR screening had a severe to profound hearing loss based on classic ABR. These patients (24% of the NICU babies with hearing losses) with hyperbilirubinemia and asphyxia problems at newborn stage were diagnosed as auditory neuropathy based on evaluations of DPOAE screening passed, abnormal ABR and absent middle-ear muscle reflexes (MMR). Our study demonstrates the use of a combination of DPOAE and AABR testing ensures high sensitivity and acceptable specificity, and predict the AN profile in NICU babies. Our efforts identified 22 NICU babies with auditory neuropathy who hopefully will benefit from early remediation of their hearing deficit. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
"Inject-mix-react-separate-and-quantitate" (IMReSQ) method for screening enzyme inhibitors.
Wong, Edmund; Okhonin, Victor; Berezovski, Maxim V; Nozaki, Tomoyoshi; Waldmann, Herbert; Alexandrov, Kirill; Krylov, Sergey N
2008-09-10
Many regulatory enzymes are considered attractive therapeutic targets, and their inhibitors are potential drug candidates. Screening combinatorial libraries for enzyme inhibitors is pivotal to identifying hit compounds for the development of drugs targeting regulatory enzymes. Here, we introduce the first inhibitor screening method that consumes only nanoliters of the reactant solutions and is applicable to regulatory enzymes. The method is termed inject-mix-react-separate-and-quantitate (IMReSQ) and includes five steps. First, nanoliter volumes of substrate, candidate inhibitor, and enzyme solutions are injected by pressure into a capillary as separate plugs. Second, the plugs are mixed inside this capillary microreactor by transverse diffusion of laminar flow profiles. Third, the reaction mixture is incubated to form the enzymatic product. Fourth, the product is separated from the substrate inside the capillary by electrophoresis. Fifth, the amounts of the product and substrate are quantitated. In this proof-of-principle work, we applied IMReSQ to study inhibition of recently cloned protein farnesyltransferase from parasite Entamoeba histolytica. This enzyme is a potential therapeutic target for antiparasitic drugs. We identified three previously unknown inhibitors of this enzyme and proved that IMReSQ could be used for quantitatively ranking the potencies of inhibitors.
Atijosan, Oluwarantimi; Kuper, Hannah; Rischewski, Dorothea; Simms, Victoria; Lavy, Christopher
2007-01-01
Background Musculoskeletal impairment (MSI) is an important cause of morbidity and mortality worldwide, especially in developing countries. Prevalence studies for MSI in the developing world have used varying methodologies and are seldom directly comparable. This study aimed to develop a new tool to screen for and diagnose MSI and to pilot test the methodology for a national survey in Rwanda. Methods A 7 question screening tool to identify cases of MSI was developed through literature review and discussions with healthcare professionals. To validate the tool, trained rehabilitation technicians screened 93 previously identified gold standard 'cases' and 86 'non cases'. Sensitivity, specificity and positive predictive value were calculated. A standardised examination protocol was developed to determine the aetiology and diagnosis of MSI for those who fail the screening test. For the national survey in Rwanda, multistage cluster random sampling, with probability proportional to size procedures will be used for selection of a cross-sectional, nationally representative sample of the population. Households to be surveyed will be chosen through compact segment sampling and all individuals within chosen households will be screened. A pilot survey of 680 individuals was conducted using the protocol. Results: The screening tool demonstrated 99% sensitivity and 97% specificity for MSI, and a positive predictive value of 98%. During the pilot study 468 out of 680 eligible subjects (69%) were screened. 45 diagnoses were identified in 38 persons who were cases of MSI. The subjects were grouped into categories based on diagnostic subgroups of congenital (1), traumatic (17), infective (2) neurological (6) and other acquired(19). They were also separated into mild (42.1%), moderate (42.1%) and severe (15.8%) cases, using an operational definition derived from the World Health Organisation's International Classification of Functioning, Disability and Health. Conclusion: The screening tool had good sensitivity and specificity and was appropriate for use in a national survey. The pilot study showed that the survey protocol was appropriate for measuring the prevalence of MSI in Rwanda. This survey is an important step to building a sound epidemiological understanding of MSI, to enable appropriate health service planning. PMID:17391509
Cancer Screening Test Use - United States, 2015.
White, Arica; Thompson, Trevor D; White, Mary C; Sabatino, Susan A; de Moor, Janet; Doria-Rose, Paul V; Geiger, Ann M; Richardson, Lisa C
2017-03-03
Healthy People 2020 (HP2020) includes objectives to increase screening for breast, cervical, and colorectal cancer (1) as recommended by the U.S. Preventive Services Task Force (USPSTF).* Progress toward meeting these objectives is monitored by measuring cancer screening test use against national targets using data from the National Health Interview Survey (NHIS) (1). Analysis of 2015 NHIS data indicated that screening test use remains substantially below HP2020 targets for selected cancer screening tests. Although colorectal cancer screening test use increased from 2000 to 2015, no improvements in test use were observed for breast and cervical cancer screening. Disparities exist in screening test use by race/ethnicity, socioeconomic status, and health care access indicators. Increased measures to implement evidence-based interventions and conduct targeted outreach are needed if the HP2020 targets for cancer screening are to be achieved and the disparities in screening test use are to be reduced.
Dual-Screened Vertical Circulation Wells for Groundwater Lowering in Unconfined Aquifers.
Jin, Yulan; Holzbecher, Ekkehard; Sauter, Martin
2016-01-01
A new type of vertical circulation well (VCW) is used for groundwater dewatering at construction sites. This type of VCW consists of an abstraction screen in the upper part and an injection screen in the lower part of a borehole, whereby drawdown is achieved without net withdrawal of groundwater from the aquifer. The objective of this study is to evaluate the operation of such wells including the identification of relevant factors and parameters based on field data of a test site and comprehensive numerical simulations. The numerical model is able to delineate the drawdown of groundwater table, defined as free-surface, by coupling the arbitrary Lagrangian-Eulerian algorithm with the groundwater flow equation. Model validation is achieved by comparing the field observations with the model results. Eventually, the influences of selected well operation and aquifer parameters on drawdown and on the groundwater flow field are investigated by means of parameter sensitivity analysis. The results show that the drawdown is proportional to the flow rate, inversely proportional to the aquifer conductivity, and almost independent of the aquifer anisotropy in the direct vicinity of the well. The position of the abstraction screen has a stronger effect on drawdown than the position of the injection screen. The streamline pattern depends strongly on the separation length of the screens and on the aquifer anisotropy, but not on the flow rate and the horizontal hydraulic conductivity. © 2015, National Ground Water Association.
Shaw, Jonathan; Saunders, John Michael; Hughes, Gwenda
2018-05-01
Chlamydia trachomatis and Neisseria gonorrhoeae testing guidance recommends extragenital screening with locally validated nucleic acid amplification tests, with anatomical sites tested separately. Evidence supports multi-patient combined aliquot pooled sampling (PS) for population screening; evidence for within-patient PS is sparse. Within-patient PS could be more cost-effective for triple-site testing, but requires distinct clinical pathways and consideration over loss of information to guide risk assessments and treatment. We explored PS attitudes and practices amongst clinicians in England. A cross-sectional web-based survey was distributed to clinical leads of sexual health services throughout England in February 2016. Fifty-two (52/216, 23%) services responded. One service reported current within-patient PS and two were awaiting implementation. Of the 49 services not pooling, five were considering implementation. Concerns raised included the inability to distinguish infection site(s) (36/52, 69%), absence of national guidance (34/52, 65%) and reduced assay performance (18/52, 34%). Only 8/52 (15%) considered the current level of evidence sufficient to support PS, with 40/52 (77%) requesting further validation studies and 39/52 (77%) national guidance. PS was rarely used by respondents to this survey, although the response rate was low. The clinical challenges presented by PS need to be addressed through further development of the evidence base.
Wang, Guifang; Lu, Gang; Zhao, Jiandi; Yin, Pinghe; Zhao, Ling
2016-08-01
Landfill-concentrated leachate from membrane separation processes is a potential pollution source for the surroundings. In this study, the toxicity and estrogenicity potentials of concentrated leachate prior to and during UV-Fenton and Fenton treatments were assessed by a combination of chemical (di (2-ethylhexyl) phthalate and dibutyl phthalate were chosen as targets) and biological (Daphnia magna, Chlorella vulgaris, and E-screen assay) analyses. Removal efficiencies of measured di (2-ethylhexyl) phthalate and dibutyl phthalate were more than 97 % after treatment with the two methods. Biological tests showed acute toxicity effects on D. magna tests in untreated concentrated leachate samples, whereas acute toxicity on C. vulgaris tests was not observed. Both treatment methods were found to be efficient in reducing acute toxicity effects on D. magna tests. The E-screen test showed concentrated leachate had significant estrogenicity, UV-Fenton and Fenton treatment, especially the former, were effective methods for reducing estrogenicity of concentrated leachate. The EEQchem (estradiol equivalent concentration) of all samples could only explain 0.218-5.31 % range of the EEQbio. These results showed that UV-Fenton reagent could be considered as a suitable method for treatment of concentrated leachate, and the importance of the application of an integrated (biological + chemical) analytical approach for a comprehensive evaluation of treatment suitability.
A Smartphone App to Screen for HIV-Related Neurocognitive Impairment.
Robbins, Reuben N; Brown, Henry; Ehlers, Andries; Joska, John A; Thomas, Kevin G F; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan
2014-02-01
Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen , to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. To examine NeuroScreen's : 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen . HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted.
Arribas, Alberto Sánchez; Bermejo, Esperanza; Zapardiel, Antonio; Téllez, Helena; Rodríguez-Flores, Juana; Zougagh, Mohammed; Ríos, Angel; Chicharro, Manuel
2009-02-01
A simple analytical scheme for the screening and quantification of zearalenone and its metabolites, alpha-zearalenol and beta-zearalenol, is reported. Extracts from maize flour samples were collected by supercritical fluid extraction and afterwards, they were analyzed by CE with amperometric detection. This scheme allowed a rapid and reliable identification of contaminated flour samples according to the reference value established for zearalenone by directive 2005/38/EC (200 microg/kg). The sample screening method was carried out by CZE using 25 mM borate separation buffer at pH 9.2 and 25.0 kV as separation voltage, monitoring the amperometric signal at +700 mV with a carbon paste electrode. In this way, total amount of mycotoxins was determined and samples were processed in 4 min with a detection limit of 12 microg/L, enough to discriminate between positive (more than 200 microg/L total mycotoxins) and negative samples (less than 200 microg/L total mycotoxins). Positive samples were then subjected to CZE separation and quantification of each analyte was done with 50 mM borate running buffer modified with 30% methanol at pH 9.7 and 17.5 kV as separation voltage. Under these conditions, separation was achieved in 15 min with detection limits from 20 to 35 microg/L for each analyte.
Page, Tessa; Nguyen, Huong Thi Huynh; Hilts, Lindsey; Ramos, Lorena; Hanrahan, Grady
2012-06-01
This work reveals a computational framework for parallel electrophoretic separation of complex biological macromolecules and model urinary metabolites. More specifically, the implementation of a particle swarm optimization (PSO) algorithm on a neural network platform for multiparameter optimization of multiplexed 24-capillary electrophoresis technology with UV detection is highlighted. Two experimental systems were examined: (1) separation of purified rabbit metallothioneins and (2) separation of model toluene urinary metabolites and selected organic acids. Results proved superior to the use of neural networks employing standard back propagation when examining training error, fitting response, and predictive abilities. Simulation runs were obtained as a result of metaheuristic examination of the global search space with experimental responses in good agreement with predicted values. Full separation of selected analytes was realized after employing optimal model conditions. This framework provides guidance for the application of metaheuristic computational tools to aid in future studies involving parallel chemical separation and screening. Adaptable pseudo-code is provided to enable users of varied software packages and modeling framework to implement the PSO algorithm for their desired use.
Nickel-hydrogen battery with oxygen and electrolyte management features
Sindorf, John F.
1991-10-22
A nickel-hydrogen battery or cell having one or more pressure vessels containing hydrogen gas and a plurality of cell-modules therein. Each cell-module includes a configuration of cooperatively associated oxygen and electrolyte mangement and component alignment features. A cell-module having electrolyte includes a negative electrode, a positive electrode adapted to facilitate oxygen diffusion, a separator disposed between the positive and negative electrodes for separating them and holding electrolyte for ionic conductivity, an absorber engaging the surface of the positive electrode facing away from the separator for providing electrolyte to the positive electrode, and a pair of surface-channeled diffusion screens for enclosing the positive and negative electrodes, absorber, and separator and for maintaining proper alignment of these components. The screens, formed in the shape of a pocket by intermittently sealing the edges together along as many as three sides, permit hydrogen gas to diffuse therethrough to the negative electrodes, and prevent the edges of the separator from swelling. Electrolyte is contained in the cell-module, absorbhed by the electrodes, the separator and the absorber.
How to report and interpret screening test properties: guidelines for driving researchers.
Weaver, Bruce; Walter, Stephen D; Bédard, Michel
2014-01-01
One important goal of driving research is the development of a short but valid office-based screening test for fitness to drive of aging drivers. Several candidate tests have been proposed already, and no doubt others will be proposed in the future. It might seem obvious that authors advocating for the adoption of a particular screening test or procedure should report sensitivity, specificity, and other common screening test properties. Unfortunately, driving researchers have frequently failed to report any screening test properties. Others have reported screening test properties but have made basic mistakes such as calculating predictive values of positive and negative tests but reporting them incorrectly as sensitivity and specificity. These omissions and errors suggest that some driving researchers may be unaware of the importance of accurately reporting test properties when proposing a screening procedure and that others may need a refresher on how to calculate and interpret the most common screening test properties. Many good learning resources for screening and diagnostic tests are available, but most of them are intended for students and researchers in medicine, epidemiology, or public health. We hope that this tutorial in a prominent transportation journal will help lead to improved reporting and interpretation of screening test properties in articles that assess the usefulness of potential screening tools for fitness to drive.
Görgens, Christian; Guddat, Sven; Orlovius, Anne-Katrin; Sigmund, Gerd; Thomas, Andreas; Thevis, Mario; Schänzer, Wilhelm
2015-07-01
In the field of LC-MS, reversed phase liquid chromatography is the predominant method of choice for the separation of prohibited substances from various classes in sports drug testing. However, highly polar and charged compounds still represent a challenging task in liquid chromatography due to their difficult chromatographic behavior using reversed phase materials. A very promising approach for the separation of hydrophilic compounds is hydrophilic interaction liquid chromatography (HILIC). Despite its great potential and versatile advantages for the separation of highly polar compounds, HILIC is up to now not very common in doping analysis, although most manufacturers offer a variety of HILIC columns in their portfolio. In this study, a novel multi-target approach based on HILIC high resolution/high accuracy mass spectrometry is presented to screen for various polar stimulants, stimulant sulfo-conjugates, glycerol, AICAR, ethyl glucuronide, morphine-3-glucuronide, and myo-inositol trispyrophosphate after direct injection of diluted urine specimens. The usage of an effective online sample cleanup and a zwitterionic HILIC analytical column in combination with a new generation Hybrid Quadrupol-Orbitrap® mass spectrometer enabled the detection of highly polar analytes without any time-consuming hydrolysis or further purification steps, far below the required detection limits. The methodology was fully validated for qualitative and quantitative (AICAR, glycerol) purposes considering the parameters specificity; robustness (rRT < 2.0%); linearity (R > 0.99); intra- and inter-day precision at low, medium, and high concentration levels (CV < 20%); limit of detection (stimulants and stimulant sulfo-conjugates < 10 ng/mL; norfenefrine; octopamine < 30 ng/mL; AICAR < 10 ng/mL; glycerol 100 μg/mL; ETG < 100 ng/mL); accuracy (AICAR 103.8-105.5%, glycerol 85.1-98.3% at three concentration levels) and ion suppression/enhancement effects.
Santos, Iná S; Tavares, Beatriz Franck; Munhoz, Tiago N; Manzolli, Patricia; de Ávila, Gisele Bartz; Jannke, Eduardo; Matijasevich, Alicia
2017-01-21
Major depressive episodes (MDE) are frequent at the population level and are generally associated with severe symptoms that impair performance of activities of daily living of individuals suffering from this condition. The aim of this study was to compare the accuracy of two tests that separately showed suitable properties in screening for MDE: the Patient Health Questionnaire-9 (PHQ-9) and the Edinburgh Postnatal Depression Scale (EPDS). In a previous study, the sensitivity and specificity of the PHQ-9 and the EPDS in screening for MDE were compared with a structured diagnostic interview conducted by psychiatrics and psychologists using the Mini International Neuropsychiatric Interview as the gold standard. In a sample of adults living in the community in Pelotas, Brazil, the PHQ-9 and EPDS were applied at the same interview and the gold standard on a median of 17 days later. The interviews were carried out at the participant's home. 447 Individuals (191 men and 256 women) were assessed. The PHQ-9 and the EPDS results were concordant in 87.5% of the respondents, with a moderate agreement beyond what was expected by chance alone (kappa = 0.61). The areas below the ROC curves were not statistically different (82.1% for PHQ-9 and 83.5% for EPDS) (p = 0.291), thus indicating that the two tests had similar moderate accuracy. PHQ-9 and EPDS may be applied with equal confidence in screening for MDE in the community.
Schejter, Eduardo; Bornstein, Jacob; Siegler, Efraim
2013-11-22
The incidence rates for premalignant lesions in Jewish women in Israel are similar to those observed in Western countries, but the incidence of cervical cancer in Israel is low; this discrepancy is not yet clearly understood. Because of the low incidence of cervical cancer in Israel, it was decided to base cervical cancer prevention on opportunistic screening: every woman from the ages of 35-54 years can have a Pap test smear free of charge every 3 years. Over the last decade 12.2% of the women population had an annual Pap test. From 36 to 50% of women who attended the Clalit Health Maintenance Organization (HMO) and the Maccabi HMO, the two largest HMOs in Israel, did so. There were also discrepancies between women of different socio-economic status (SES): <10% in the lowest SES level were screened compared to almost 55% in the higher level. HPV vaccination was opportunistic but it will be introduced to the school-based vaccine program at age of 13 years old as of September 2013. The Israel Society of Obstetrics and Gynecology recommends continuing cytologic screening in vaccinated women as recommended for the general population. This article forms part of a regional report entitled "Comprehensive Control of HPV Infections and Related Diseases in Israel" Vaccine Volume 31, Supplement 8, 2013. Updates of the progress in the field are presented in a separate monograph entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2013. Published by Elsevier Ltd.
Santos, Iná S; Tavares, Beatriz Franck; Munhoz, Tiago N; Manzolli, Patricia; de Ávila, Gisele Bartz; Jannke, Eduardo; Matijasevich, Alicia
2016-09-27
Major depressive episodes (MDE) are frequent at the population level and are generally associated with severe symptoms that impair performance of activities of daily living of individuals suffering from this condition. The aim of this study was to compare the accuracy of two tests that separately showed suitable properties in screening for MDE: the Patient Health Questionnaire-9 (PHQ-9) and the Edinburgh postnatal depression scale (EPDS). In a previous study, the sensitivity and specificity of the PHQ-9 and the EPDS in screening for MDE were compared with a structured diagnostic interview conducted by psychiatrics and psychologists using the Mini International Neuropsychiatric Interview as the gold standard. In a sample of adults living in the community in Pelotas, Brazil, the PHQ-9 and EPDS were applied at the same interview and the gold standard on a median of 17 days later. The interviews were carried out at the participant's home. 447 individuals (191 men and 256 women) were assessed. The PHQ-9 and the EPDS results were concordant in 87.5 % of the respondents, with a moderate agreement beyond what was expected by chance alone (kappa = 0.61). The areas below the ROC curves were not statistically different (82.1 % for PHQ-9 and 83.5 % for EPDS) (p = 0.291), thus indicating that the two tests had similar moderate accuracy. PHQ-9 and EPDS may be applied with equal confidence in screening for MDE in the community.
Screening for HIV infection by health professionals in India.
Kurien, M; Thomas, K; Ahuja, R C; Patel, A; Shyla, P R; Wig, N; Mangalani, M; Sathyanathan; Kasthuri, A; Vyas, B; Brogen, A; Brojen, A; Sudarsanam, T D; Chaturvedi, A; Abraham, O C; Tharyan, P; Selvaraj, K G; Mathew, J
2007-01-01
Stigma and discrimination, particularly in access to healthcare, remains a major problem for people Infected with HIV in most parts of India. We did a multicentre study (n = 10) with a cross-sectional survey design using a standardized, interviewer-administered questionnaire. A total of 2200 healthcare providers participated. The knowledge, attitude and practice (KAP) related to HIV service delivery were very poor with a mean overall KAP score of only 49.7% (CI: 49.1-50.3). Only 5%, 5% and 1% of the participants scored more than 75% separately for the dimensions of knowledge, attitude and practice, respectively. Only 24.4% and 36.7% of responders knew that HIV screening was not recommended prior to surgery and pre-employment check-up. Many doctors (19.4%) had refused treatment to people living with HIV/AIDS (PLHA) at least some of the time and nearly half (47.2%) identified and labelled them; 23.9% isolated them in separate care areas and 13.3% postponed or changed treatment based on the patient's HIV status. Screening for HIV prior to elective surgery was done by 67% of providers. While 64.7% of responders were aware of the existence of national guidelines on and recommendations for HIV testing, only 38.4% had read the policy document. There is a growing need to provide care, support and treatment to a large number of PLHA. The capacity of healthcare providers must be urgently built up so as to improve their knowledge of and attitude to HIV to enable them to deliver evidence-based and compassionate care to PLHA in various healthcare settings.
Liquid Loss From Advancing Aqueous Foams With Very Low Water Content
2011-01-14
fractionation used by pharmaceutical and food industries for protein separation, and froth flotation used by the mining industry for mineral separation...SureShotsSprayer.com) onto a copper screen with a diameter of 6.4 cm and 30x30 mesh cells per inch (40.8% open area) held in place by a rubber gasket. The N2 pressure...distribution over the copper screen. Air flow rates of 8 L/min and 20 L/min, as determined by a mass-flow controller (Sierra Control Flo-Box Model
Interaction of microtubules with active principles of Xanthium strumarium.
Menon, G S; Kuchroo, K; Dasgupta, D
2001-01-01
Indigenous variety of Xanthium strumarium (X. strumarium) was screened for its antimitotic activity using the microtubule-tubulin system isolated from mammalian tissue. A preliminary phytochemical screening of the whole extracts of the plant was carried out followed by partial purification of the whole extract of X.strumarium. The separated fractions obtained were identified and used for in vitro polymerization studies. The whole as well as partially separated chemical constituents of X. strumarium showed effective inhibition of tubulin polymerization. The results thus suggest that X. strumarium may possess antimitotic components.
TREATMENT AND SOLIDS MANAGEMENT
A variety of high-rate treatment methods show a potential to handle WWF including: physical separation with and without chemical addition (e.g., enhanced settling, fine-mesh screening, vortex separation, dual-media high-rate filtration, dissolved air flotation, activated carbon, ...
The use of hydrodynamic vortex separators and screening systems to improve water quality.
Andoh, R Y G; Saul, A J
2003-01-01
The paper reviews the evolution of Hydrodynamic Vortex Separators (HDVS) in the context of application as high rate rotary flow separators for achieving water quality improvements to meet with regulatory requirements in Europe and North America. The types of HDVS and their application for the control of wet-weather discharges such as combined sewer overflows (CSOs), sanitary sewer overflows (SSOs) and stormwater are outlined and a number of myths surrounding their use, dispelled. Reference is made to outputs of peer reviewed comprehensive monitoring, evaluation and demonstration projects on pilot and full-scale installations to demonstrate the efficacy and extensive track record of these systems. Recent developments and innovations in HDVS technologies are discussed, focusing on their combined use as solids liquid separators, contact vessels for wastewater disinfection, the incorporation of self-cleansing screening devices for the control of aesthetic pollutants (e.g. floatables) and the use of computational modelling for optimisation.
To Screen or Not to Screen? The Benefits and Harms of Screening Tests
... issue To Screen or Not to Screen? The Benefits and Harms of Screening Tests En español Send ... test, talk with your doctor about the possible benefits and harms to help you decide what’s best ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miyai, K.; Oura, T.; Kawashima, M.
1978-11-01
A simple and reliable method of paired TSH assay was developed and used in screening for neonatal primary hypothyroidism. In this method, a paired assay is first done. Equal parts of the extracts of dried blood spots on filter paper (9 mm diameter) from two infants 4 to 7 days old are combined and assayed for TSH by double antibody RIA. If the value obtained is over the cut-off point, the extracts are assayed separately for TSH in a second assay to identify the abnormal sample. Two systems, A and B, with different cut-off points were tested. On the basismore » of reference blood samples (serum levels of TSH, 80 ..mu..U/ml in system A and 40 ..mu..U/ml in system B), the cut-off point was selected as follows: upper 5 (A) or 4 (B) percentile in the paired assay and values of reference blood samples in the second individual assay. Four cases (2 in A and 2 in B) of neonatal primary hypothyroidism were found among 25 infants (23 in A and 2 in B) who were recalled from a general population of 41,400 infants (24,200 in A and 17,200 in B) by 22,700 assays. This paired TSH assay system saves labor and expense for screening neonatal hypothyroidism.« less
Sub-tesla-field magnetization of vibrated magnetic nanoreagents for screening tumor markers
NASA Astrophysics Data System (ADS)
Chieh, Jen-Jie; Huang, Kai-Wen; Shi, Jin-Cheng
2015-02-01
Magnetic nanoreagents (MNRs), consisting of liquid solutions and magnetic nanoparticles (MNPs) coated with bioprobes, have been widely used in biomedical disciplines. For in vitro tests of serum biomarkers, numerous MNR-based magnetic immunoassay methods or schemes have been developed; however, their applications are limited. In this study, a vibrating sample magnetometer (VSM) was used for screening tumor biomarkers based on the same MNRs as those used in other immunoassay methods. The examination mechanism is that examined tumor biomarkers are typically conjugated to the bioprobes coated on MNPs to form magnetic clusters. Consequently, the sub-Tesla-field magnetization (Msub-T) of MNRs, including magnetic clusters, exceeds that of MNRs containing only separate MNPs. For human serum samples, proteins other than the targeted biomarkers induce the formation of magnetic clusters with increased Msub-T because of weak nonspecific binding. In this study, this interference problem was suppressed by the vibration condition in the VSM and analysis. Based on a referenced Msub-T,0 value defined by the average Msub-T value of a normal person's serum samples, including general proteins and few tumor biomarkers, the difference ΔMsub-T between the measured Msub-T and the reference Msub-T,0 determined the expression of only target tumor biomarkers in the tested serum samples. By using common MNRs with an alpha-fetoprotein-antibody coating, this study demonstrated that a current VSM can perform clinical screening of hepatocellular carcinoma.
Protein electrophoresis as a diagnostic and prognostic tool in raptor medicine.
Tatum, L M; Zaias, J; Mealey, B K; Cray, C; Bossart, G D
2000-12-01
Plasma proteins of 139 healthy adult birds of prey from 10 species were separated by electrophoresis to characterize and document normal reference ranges and species-specific electrophoretic patternsand to evaluate the value of this technique for health screening, disease diagnosis, and prognostic indication. Species studied included bald eagle (Haliaeetus leucocephalus), red-tailed hawk (Buteo jamaicensis), barn owl (Tyto alba), great horned owl (Bubo virginianus), turkey vulture (Cathartes aura), Harris' hawk (Parabuteo unicinctus), Stellar's sea eagle (Haliaeetus pelagicus), barred owl (Strix varia), screech owl (Otus asio), and black vulture (Coragyps atratus). Several clinical cases show the diagnostic/therapeutic value of protein electrophoresis in raptors. This study establishes species-specific reference ranges for several birds of prey and discusses the benefit of electrophoresis as a diagnostic technique in health screens, as a diagnostic aid in conjunction with other tests, and as a prognostic indicator in clinical evaluation of raptors.
Lin, Pingtan; Zhao, Shulin; Lu, Xin; Ye, Fanggui; Wang, Hengshan
2013-08-01
A CE method based on a dual-enzyme co-immobilized capillary microreactor was developed for the simultaneous screening of multiple enzyme inhibitors. The capillary microreactor was prepared by co-immobilizing adenosine deaminase and xanthine oxidase on the inner wall at the inlet end of the separation capillary. The enzymes were first immobilized on gold nanoparticles, and the functionalized gold nanoparticles were then assembled on the inner wall at the inlet end of the separation capillary treated with polyethyleneimine. With the developed CE method, the substrates and products were baseline separated within 3 min. The activity of the immobilized enzyme can be directly detected by measuring the peak height of the products. A statistical parameter Z' factor was recommended for evaluation of the accuracy of a drug screening system. In the present study, it was calculated to be larger than 0.5, implying a good accuracy. Finally, screening a small compound library containing two known enzyme inhibitors and 20 natural extracts by the proposed method was demonstrated. The known inhibitors were identified, and some natural extracts were found to be positive for two-enzyme inhibition by the present method. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Jiao; Tian, Ji; Li, Jin; Azietaku, John Teye; Zhang, Bo-Li; Gao, Xiu-Mei; Chang, Yan-Xu
2016-07-01
An in-capillary 2, 2-diphenyl-1-picrylhydrazyl (DPPH)-CE-the DAD (in-capillary DPPH-CE-DAD) combined with reversed-electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β-CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p-coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH-CE-DAD method. Sensitivity was enhanced under reversed-electrode polarity stacking mode and 10- to 31-fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in-capillary DPPH-CE-DAD method combined with reversed-electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A Smartphone App to Screen for HIV-Related Neurocognitive Impairment
Robbins, Reuben N.; Brown, Henry; Ehlers, Andries; Joska, John A.; Thomas, Kevin G.F.; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan
2014-01-01
Background Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen, to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. Aims To examine NeuroScreen’s: 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Methods Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen. HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. Results There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. Conclusion NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted. PMID:24860624
Improving rates of screening and prevention by leveraging existing information systems.
Neil, Nancy
2003-11-01
In 1997 Virginia Mason Health System (VMMC), a vertically integrated hospital and multispecialty group practice, had no process or system to deliver the right patient clinical data, in the right form, at the right place--when providers needed it for effective patient care. Without any new investment in technology, a work group of five individuals leveraged existing, primarily paper-based information systems to launch development and implementation of a provider prompting tool--a primary care and prevention (PCP) report--which prompted providers to complete screening, prevention, and disease management services at every patient appointment. The work group developed and pilot tested the report and created a mechanism by which the report could be delivered just in time before each patient's appointment. The report integrated information from independent appointment scheduling, laboratory results reporting, patient demographics, and billing data sources. MEASURING THE PCP REPORT'S IMPACT: The results of two separate analyses demonstrate improvement in rates of screening and prevention across VMMC soon after the PCP report became available. These results led senior leadership to make the PCP report's utilization a systemwide imperative. The PCP report is used by nearly all primary care providers as a prompt to complete screening, prevention, and disease management services at every patient appointment.
Continuous-flow separation of live and dead yeasts using reservoir-based dielectrophoresis (rDEP)
NASA Astrophysics Data System (ADS)
Patel, Saurin; Showers, Daniel; Vedantam, Pallavi; Tzeng, Tzuen-Rong; Qian, Shizhi; Xuan, Xiangchun
2012-11-01
Separating live and dead cells is critical to the diagnosis of early stage diseases and to the efficacy test of drug screening etc. We develop a novel microfluidic approach to continuous separation of yeast cells by viability inside a reservoir. It exploits the cell dielectrophoresis that is induced by the inherent electric field gradient at the reservoir-microchannel junction to selectively trap dead yeasts and continuously sort them from live ones. We term this approach reservoir-based dielectrophoresis (rDEP). The transporting, focusing, and trapping of live and dead yeast cells at the reservoir-microchannel junction are studied separately by varying the DC-biased AC electric fields. These phenomena can all be reasonably predicted by a 2D numerical model. We find that the AC to DC field ratio for live yeast trapping is higher than that for dead cells because the former experiences a weaker rDEP while having a larger electrokinetic mobility. It is this difference in the AC to DC field ratio that enables the viability-based yeast cell separation. The rDEP approach has unique advantages over existing DEP-based techniques such as the occupation of zero channel space and the elimination of in-channel mechanical or electrical parts. NSF
HYDROCARBON SPILL SCREENING MODEL (HSSM) VOLUME 1: USER'S GUIDE
This users guide describes the Hydrocarbon Spill Screening Model (HSSM). The model is intended for simulation of subsurface releases of light nonaqueous phase liquids (LNAPLs). The model consists of separate modules for LNAPL flow through the vadose zone, spreading in the capil...
Thermodynamics of Thomas-Fermi screened Coulomb systems
NASA Technical Reports Server (NTRS)
Firey, B.; Ashcroft, N. W.
1977-01-01
We obtain in closed analytic form, estimates for the thermodynamic properties of classical fluids with pair potentials of Yukawa type, with special reference to dense fully ionized plasmas with Thomas-Fermi or Debye-Hueckel screening. We further generalize the hard-sphere perturbative approach used for similarly screened two-component mixtures, and demonstrate phase separation in this simple model of a liquid mixture of metallic helium and hydrogen.
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...
Keen, P; Conway, D P; Cunningham, P; McNulty, A; Couldwell, D L; Davies, S C; Smith, D E; Gray, J; Holt, M; O'Connor, C C; Read, P; Callander, D; Prestage, G; Guy, R
2017-01-01
The Trinity Biotech Uni-Gold HIV test (Uni-Gold) is often used as a supplementary rapid test in testing algorithms. To evaluate the operational performance of the Uni-Gold as a first-line screening test among gay and bisexual men (GBM) in a setting where 4th generation HIV laboratory assays are routinely used. We compared the performance of Uni-Gold with conventional HIV serology conducted in parallel among GBM attending 22 testing sites. Sensitivity was calculated separately for acute and established infection, defined using 4th generation screening Ag/Ab immunoassay (EIA) and Western blot results. Previous HIV testing history and results of supplementary 3rd generation HIV Ab EIA, and p24 antigen EIA were used to further characterise cases of acute infection. Of 10,793 specimens tested with Uni-Gold and conventional serology, 94 (0.90%, 95%CI:0.70-1.07) were confirmed as HIV-positive by conventional serology, and 37 (39.4%) were classified as acute infection. Uni-Gold sensitivity was 81.9% overall (77/94, 95%CI:72.6-89.1); 56.8% for acute infection (21/37, 95%CI:39.5-72.9) and 98.2% for established infection (56/57, 95%CI:90.6-100.0). Of 17 false non-reactive Uni-Gold results, 16 were acute infections, and of these seven were p24 antigen reactive but antibody negative. Uni-Gold specificity was 99.9% (10,692/10,699, 95%CI:99.9-100.0), PPV was 91.7% (95%CI:83.6-96.6) and NPV was 99.8% (95%CI:99.7-99.9), respectively. In this population, Uni-Gold had good specificity and sensitivity was high for established infections when compared to 4th generation laboratory assays, however sensitivity was lower in acute infections. Where rapid tests are used in populations with a high proportion of acute infections, additional testing strategies are needed to detect acute infections. Copyright © 2016 Elsevier B.V. All rights reserved.
Screening Mammography & Breast Cancer Mortality: Meta-Analysis of Quasi-Experimental Studies
Irvin, Veronica L.; Kaplan, Robert M.
2014-01-01
Background The magnitude of the benefit associated with screening has been debated. We present a meta-analysis of quasi-experimental studies on the effects of mammography screening. Methods We searched MEDLINE/PubMed and Embase for articles published through January 31, 2013. Studies were included if they reported: 1) a population-wide breast cancer screening program using mammography with 5+ years of data post-implementation; 2) a comparison group with equal access to therapies; and 3) breast cancer mortality. Studies excluded were: RCTs, case-control, or simulation studies. We defined quasi-experimental as studies that compared either geographical, historical or birth cohorts with a screening program to an equivalent cohort without a screening program. Meta-analyses were conducted in Stata using the metan command, random effects. Meta-analyses were conducted separately for ages screened: under 50, 50 to 69 and over 70 and weighted by population and person-years. Results Among 4,903 published papers that were retrieved, 19 studies matched eligibility criteria. Birth cohort studies reported a significant benefit for women screened
Hankin, Abigail; Freiman, Heather; Copeland, Brittney; Travis, Natasha; Shah, Bijal
2016-01-01
This study compared two approaches for implementation of non-targeted HIV screening in the emergency department (ED): (1) designated HIV counselors screening in parallel with ED care and (2) nurse-based screening integrated into patient triage. A retrospective analysis was performed to compare parallel and integrated screening models using data from the first 12 months of each program. Data for the parallel screening model were extracted from information collected by HIV test counselors and the electronic medical record (EMR). Integrated screening model data were extracted from the EMR and supplemented by data collected by HIV social workers during patient interaction. For both programs, data included demographics, HIV test offer, test acceptance or declination, and test result. A Z-test between two proportions was performed to compare screening frequencies and results. During the first 12 months of parallel screening, approximately 120,000 visits were made to the ED, with 3,816 (3%) HIV tests administered and 65 (2%) new diagnoses of HIV infection. During the first 12 months of integrated screening, 111,738 patients were triaged in the ED, with 16,329 (15%) patients tested and 190 (1%) new diagnoses. Integrated screening resulted in an increased frequency of HIV screening compared with parallel screening (0.15 tests per ED patient visit vs. 0.03 tests per ED patient visit, p<0.001) and an increase in the absolute number of new diagnoses (190 vs. 65), representing a slight decrease in the proportion of new diagnoses (1% vs. 2%, p=0.007). Non-targeted, integrated HIV screening, with test offer and order by ED nurses during patient triage, is feasible and resulted in an increased frequency of HIV screening and a threefold increase in the absolute number of newly identified HIV-positive patients.
2014-01-01
Background X-ray mammography remains the predominant test for screening for breast cancer, with the aim of reducing breast cancer mortality. In the English NHS Breast Screening Programme each woman’s mammograms are examined separately by two expert readers. The two readers read each batch in the same order and each indicates if there should be recall for further tests. This is a highly skilled, pressurised, repetitive and frequently intellectually unchallenging activity where readers examine one or more batches of 30–50 women’s mammograms in each session. A vigilance decrement or performance decrease over time has been observed in similar repetitive visual tasks such as radar operation. Methods/Design The CO-OPS study is a pragmatic, multi-centre, two-arm, double blind cluster randomised controlled trial of a computer software intervention designed to reduce the effects of a vigilance decrement in breast cancer screening. The unit of randomisation is the batch. Intervention batches will be examined in the opposite order by the two readers (one forwards, one backwards). Control batches will be read in the same order as one another, as is current standard practice. The hypothesis is that cancer detection rates will be higher in the intervention group because each readers’ peak performance will occur when examining different women’s mammograms. The trial will take place in 44 English breast screening centres for 1 year and 4 months. The primary outcome is cancer detection rate, which will be extracted from computer records after 1 year of the trial. The secondary outcomes include rate of disagreement between readers (a more statistically powerful surrogate for cancer detection rate), recall rate, positive predictive value, and interval cancer rate (cancers found between screening rounds which will be measured three years after the end of the trial). Discussion This is the first trial of an intervention to ameliorate a vigilance decrement in breast cancer screening. Trial registration ISRCTN46603370 (submitted: 24 October 2012, date of registration: 26 March 2013). PMID:24411004
Risks of Prostate Cancer Screening
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...
Breast, prostate, and thyroid cancer screening tests and overdiagnosis.
Jung, Minsoo
The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.
Screening for anxiety disorders in children.
Simon, Ellin; Bögels, Susan Maria
2009-10-01
Anxiety disorders are highly prevalent and have negative consequences on individual and societal level. This study examined the usefulness of screening for anxiety disorders in primary school children. More specifically, the value of the screening method to discriminate between and to predict anxiety disorders was studied. Children and their parents were selected if the children had self-reported scores on the screening questionnaire Screen for Child Anxiety Related Emotional Disorders-71 (SCARED-71) within the top-15% (High-anxious) or from two points below to two points above the median (Median-anxious). Of the selected children, 183 high-anxious children and their parents, and 80 median-anxious children and their parents took part in a diagnostic interview, the Anxiety Disorder Interview Schedule (ADIS). Of the high-anxious children, 60% had an anxiety disorder versus 23% of the median-anxious children, whereas groups did not differ on rates of dysthymia/depression and attention deficit hyperactivity disorder. The diagnoses separation anxiety disorder, social phobia and specific phobia were specifically predicted by the corresponding subscales of the screening questionnaire, while the diagnosis generalised anxiety disorder was not predicted by any of the subscales. The screening method has proven its utility for discriminating between children with and without anxiety disorders when applying the top-15% cut-off. Moreover, separation anxiety disorder, social phobia, and specific phobia, all known to be prevalent and debilitating childhood anxiety disorders, can be predicted by the corresponding subscale of the screening instrument.
Cancer Screening: How Do Screening Tests Become Standard Tests?
... more groups. The people in one group (the control group ) may be given a standard screening test (if one exists) or no screening test. The ... for the human papillomavirus (HPV) and those who test negative for HPV. The ... Case-control studies Case-control studies are like cohort studies ...
Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram
2014-10-17
Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.
Banerjee, Kaushik; Patil, Sangram H; Dasgupta, Soma; Oulkar, Dasharath P; Patil, Shubhangi B; Savant, Rahul; Adsule, Pandurang G
2008-05-09
A comprehensive GCxGC-TOFMS method was optimized for multiresidue analysis of pesticides using a combination of a non-polar (RTX-5MS, 10 m x 0.18 mm x 0.2 microm) and a polar capillary column (TR-50MS, 1 m x 0.1 mm x 0.1 microm), connected in series through a dual stage thermal modulator. The method resolved the co-elution problems as observed in full scan one-dimensional GC-MS analysis and allowed chromatographic separation of 51 pesticides within 24 min run time with library-searchable mass spectrometric confirmation. Four pesticides, viz. chlorpyrifos-methyl, vinclozoline, parathion-methyl and heptachlor could be baseline separated on GCxGC, which were otherwise closely eluting and interfering each other's detection in 1D GC-MS run. Similarly, it could be possible to separate myclobutanil, buprofezin, flusilazole and oxyfluorfen on GCxGC. Although in 1D GC-MS, these closely eluting compounds could be identified through deconvolution algorithm and 'peak-find' option of the Chromatof software but the spectral purity significantly improved on GCxGC analysis. Thorough optimization was accomplished for the oven temperature programming, ion source temperature and GCxGC parameters like modulation period, duration of hot pulses, modulation-offset temperature, acquisition rate, etc. to achieve best possible separation of the test compounds. The limit of detection significantly improved by 2-12 times on GCxGC-TOFMS against GC-TOFMS because of sharper and narrower peak shapes. The method was tested for grape matrix after preparing the samples using previously described method and recoveries of the entire test pesticides were within 70-110% at 10 ng/g level of fortification. GCxGC-TOFMS was found to be an excellent technique for library-based screening of pesticides with high accuracy and sensitivity.
Hong, Xinying; Kumar, Arun Babu; Ronald Scott, C; Gelb, Michael H
2018-03-29
All States screen for biotinidase deficiency and galactosemia, and X-linked adrenoleukodystrophy (X-ALD) has recently been added to the Recommended Uniform Screening Panel (RUSP).We sought to consolidate these tests by combining them into a single multiplex tandem mass spectrometry assay as well as to improve the current protocol for newborn screening of galactosemia.A 3 mm punch of a dried blood spot (DBS) was extracted with organic solvent for analysis of the C26:0-lysophosphatidylcholine biomarker for X-ALD.An additional punch was used to assay galactose-1-phosphate uridyltransferase (GALT) and biotinidase.All assays were combined for a single injection for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) (2.3 min per sample).The GALT LC-MS/MS assay does not give a false positive for galactosemia if glucose-6-phosphate dehydrogenase is deficient.The multiplex assay shows acceptable reproducibility and provides for rapid analysis of X-ALD, biotinidase deficiency, and galactosemia.The throughput and ease of sample preparation are acceptable for newborn screening laboratories.We also show that the LC-MS/MS assay is expandable to include several other diseases including Pompe and Hurler diseases (enzymatic activities and biomarkers).Because of consolidation of assays, less manpower is needed compared to running individual assays on separate platforms.The flexibility of the LC-MS/MS platform allows each newborn screening laboratory to analyze the set of diseases offered in their panel. Copyright © 2018 Elsevier Inc. All rights reserved.
Payne, Ann; Barry, Sandra; Creedon, Brian; Stone, Carol; Sweeney, Catherine; O' Brien, Tony; O' Sullivan, Kathleen
2007-04-01
The primary objective in this study is to determine the sensitivity and specificity of a two-item screening interview for depression versus the formal psychiatric interview, in the setting of a specialist palliative in-patient unit so that we may identify those individuals suffering from depressive disorder and therefore optimise their management in this often-complex population. A prospective sample of consecutive admissions (n = 167) consented to partake in the study, and the screening interview was asked separately to the formal psychiatric interview. The two-item questionnaire, achieved a sensitivity of 90.7% (95% CI 76.9-97.0) but a lower specificity of 67.7% (95% CI 58.7-75.7). The false positive rate was 32.3% (95% CI 24.3-41.3), but the false negative rate was found to be a low 9.3% (95% CI 3.0-23.1). A subgroup analysis of individuals with a past experience of depressive illness, (n = 95), revealed that a significant number screened positive for depression by the screening test, 55.2% (16/29) compared to those with no background history of depression, 33.3% (22/66) (P = 0.045). The high sensitivity and low false negative rate of the two-question screening tool will aid health professionals in identifying depression in the in-patient specialist palliative care unit. Individuals, who admit to a previous experience of depressive illness, are more likely to respond positively to the two-item questionnaire than those who report no prior history of depressive illness (P = 0.045).
Depot effect of bioactive components in experimental membrane filtrations
NASA Astrophysics Data System (ADS)
Mitev, D.; Peshev, D.; Peev, G.; Peeva, L.
2017-01-01
Depot effects were found to be accompanying phenomena of membrane separation processes. Accumulation of target species in the membrane matrix during feasibility tests can hamper proper conclusions or compromise the filtration results. Therefore, we investigated the effects of delayed membrane release of chlorogenic acid and caffeine, considered as key compounds of interest in spent coffee products’ recovery treatment. Permeate fluxes and key components release were studied in course of 24 hours via nanofiltration of pure solvent, both immediately after the mock solution filtration and after idle stay. Conclusions are drawn and recommendations advised for proper analysis of experimental data on membrane screening.
The U.S. Environmental Protection Agency is evaluating methods to screen and prioritize large numbers of chemicals for developmental toxicity. As part of this approach, it is important to be able to separate overt toxicity (Le., malformed larvae) from the more specific neurotoxic...
Adherence to multiple cancer screening tests among women living in Appalachia Ohio
Katz, Mira L.; Reiter, Paul L.; Young, Gregory S.; Pennell, Michael L.; Tatum, Cathy M.; Paskett, Electra D.
2015-01-01
Background There is a lack of information about the correlates of completing all three cancer screening tests among women living in Appalachia. Methods Cross-sectional telephone interviews were conducted (April-September 2013) among women (n=637) ages 51-75 from 12 Appalachia Ohio counties. Outcomes of within screening guidelines were verified by medical record. Multivariable logistic regression models identified correlates of being within guidelines for all three cancer screening tests. Results Screening rates were: mammography (32.1%), Pap test (36.1%), and a colorectal cancer test (30.1%). Only 8.6% of women were within guidelines for all tests. Having had a check-up in the past two years and having received a screening recommendation were significantly related to being within guidelines for all three tests (p<0.01). Participants with higher annual household incomes ($60,000+; OR=3.53, 95% CI: 1.49, 8.33) and conditions requiring regular medical visits (OR=3.16, 95% CI: 1.29, 7.74) were more likely to be within guidelines for all three screening tests. Conclusion Less than 10% of women had completed screening within guidelines for all three screening tests. Regular contact with the healthcare system and higher incomes were significant predictors of being within guidelines. Impact Within guidelines rates for the three recommended cancer screening tests is low among women in Appalachia Ohio. This finding illustrates the need for innovative interventions to improve rates of multiple cancer screening tests. PMID:26282630
2014-01-01
Background It is important to understand the specific HPV genotype distribution in screen-detected lesions. HPV Genotype is helpful for separating HPV-positive women at greater risk of cancer from those who can regress spontaneously and for preventing cervical cancer at early stage. The aim of this study was to investigate the high-risk HPV genotype distribution among cervical cytology abnormality in Pearl River Delta Region, Southern China Methods 5585 HPV-infected women were screened from 77069 women in Pearl River Delta Region. Information was obtained from 3226 screened subjects through questionnaires and personal interviews. Exfoliated cervical cells were collected by doctors for HPV test with MassARRAY (Sequenom, Sandiego, CA) technique based on the matrix-assisted laser desorption/ionization time-of flight (MALDI-TOF) mass spectrometry (MS). The ThinPrep cytology test was performed to screen for cervical cancer. Unconditional logistic was used to determine the most common HPV carcinogenic types. Results Of the 3226 HPV-positive samples tested, 1744 (54.1%) with normal cervical cytology, 1482 (45.9%) with abnormal cytology. The five most common HPV types in this study were HPV16 (20.2%), HPV52 (17.1%), HPV58 (13.2%), HPV18 (9.5%), HPV6 (7.6%). Overall, HPV16 (OR = 10.5, 95% CI: 3.7 ~ 29.6), HPV33 (OR = 9.1, 95% CI: 2.8 ~ 29.2), HPV58 (OR = 6.3, 95% CI: 2.1 ~ 18.6), HPV31 (OR = 4.5, 95% CI: 1.3 ~ 15.5), multiple genotype infection (OR = 3.0, 95% CI: 1.7 ~ 14.7), especially HPV16 and HPV33, increased the risk of cytology abnormalities. Conclusions HPV16, HPV31, HPV33, HPV58, and multiple HPV genotype infection increased the risk of cytology abnormalities in Pearl River Delta Region and might be useful for the screening, preventing, treating, and monitoring of pre-cancer lesions in southern China. PMID:25016305
Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome
Wald, Nicholas J.; Bestwick, Jonathan P.
2013-01-01
Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014
Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?
Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J
2015-11-01
We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.
Harik-Khan, R; Moats, W A
1995-01-01
A procedure for identifying and quantitating violative beta-lactams in milk is described. This procedure integrates beta-lactam residue detection kits with the multiresidue automated liquid chromatographic (LC) cleanup method developed in our laboratory. Spiked milk was deproteinized, extracted, and subjected to reversed-phase LC using a gradient program that concentrated the beta-lactams. Amoxicillin, ampicillin, cephapirin, ceftiofur, cloxacillin, and penicillin G were, thus, separated into 5 fractions that were subsequently tested for activity by using 4 kits. beta-lactams in the positive fractions were quantitated by analytical LC methods developed in our laboratory. The LC cleanup method separated beta-lactam antibiotics from each other and from interferences in the matrix and also concentrated the antibiotics, thus increasing the sensitivity of the kits to the beta-lactam antibiotics. The procedure facilitated the task of identifying and measuring the beta-lactam antibiotics that may be present in milk samples.
Testing and screening for chlamydia in general practice: a cross-sectional analysis.
Thomson, Allison; Morgan, Simon; Henderson, Kim; Tapley, Amanda; Spike, Neil; Scott, John; van Driel, Mieke; Magin, Parker
2014-12-01
Chlamydia screening is widely advocated. General practice registrars are an important stage of clinical behaviour development. This study aimed to determine rates of, and factors associated with, registrars' chlamydia testing including asymptomatic screening. A cross-sectional analysis of data from Registrars Clinical Encounters in Training (ReCEnT), a cohort study of registrars' consultations. Registrars record details of 60 consecutive consultations in each GP-term of training. Outcome factors were chlamydia testing, asymptomatic screening and doctor-initiated screening. Testing occurred in 2.5% of 29,112 consultations (398 registrars) and in 5.8% of patients aged 15-25. Asymptomatic screening comprised 47.5% of chlamydia tests, and 55.6% of screening tests were doctor-initiated. Chlamydia testing was associated with female gender of doctor and patient, younger patient age, and patients new to doctor or practice. Asymptomatic screening was associated with practices where patients incur no fees, and in patients new to doctor or practice. Screening of female patients was more often doctor-initiated. GP registrars screen for chlamydia disproportionately in younger females and new patients. Our findings highlight potential opportunities to improve uptake of screening for chlamydia, including targeted education and training for registrars, campaigns targeting male patients, and addressing financial barriers to accessing screening services. © 2014 Public Health Association of Australia.
Benning, Tim M; Dellaert, Benedict G C; Severens, Johan L; Dirksen, Carmen D
2014-07-01
Many national colorectal cancer screening campaigns have a similar structure. First, individuals are invited to take a noninvasive screening test, and, second, in the case of a positive screening test result, they are advised to undergo a more invasive follow-up test. The objective of this study was to investigate how much individuals' participation decision in noninvasive screening is affected by the presence or absence of detailed information about invasive follow-up testing and how this effect varies over screening tests. We used a labeled discrete choice experiment of three noninvasive colorectal cancer screening types with two versions that did or did not present respondents with detailed information about the possible invasive follow-up test (i.e., colonoscopy) and its procedure. We used data from 631 Dutch respondents aged 55 to 75 years. Each respondent received only one of the two versions (N = 310 for the invasive follow-up test information specification version, and N = 321 for the no-information specification version). Mixed logit model results show that detailed information about the invasive follow-up test negatively affects screening participation decisions. This effect can be explained mainly by a decrease in choice shares for the most preferred screening test (a combined stool and blood sample test). Choice share simulations based on the discrete choice experiment indicated that presenting invasive follow-up test information decreases screening participation by 4.79%. Detailed information about the invasive follow-up test has a negative effect on individuals' screening participation decisions in noninvasive colorectal cancer screening campaigns. This result poses new challenges for policymakers who aim not only to increase uptake but also to provide full disclosure to potential screening participants. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Abnormal Cervical Cancer Screening Test Results
... FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • What is the difference between the terms cervical ...
Characterization of Phase Separation Propensity for Amorphous Spray Dried Dispersions.
McNamara, Daniel; Yin, Shawn; Pan, Duohai; Crull, George; Timmins, Peter; Vig, Balvinder
2017-02-06
A generalized screening approach, applying isothermal calorimetry at 37 °C 100% RH, to formulations of spray dried dispersions (SDDs) for two active pharmaceutical ingredients (APIs) (BMS-903452 and BMS-986034) is demonstrated. APIs 452 and 034, with similar chemotypes, were synthesized and promoted during development for oral dosing. Both APIs were formulated as SDDs for animal exposure studies using the polymer hydroxypropylmethlycellulose acetyl succinate M grade (HPMCAS-M). 452 formulated at 30% (wt/wt %) was an extremely robust SDD that was able to withstand 40 °C 75% RH open storage conditions for 6 months with no physical evidence of crystallization or loss of dissolution performance. Though 034 was a chemical analogue with similar physical chemical properties to 452, a physically stable SDD of 034 could not be formulated in HPMCAS-M at any of the drug loads attempted. This study was used to develop experience with specific physical characterization laboratory techniques to evaluate the physical stability of SDDs and to characterize the propensity of SDDs to phase separate and possibly crystallize. The screening strategy adopted was to stress the formulated SDDs with a temperature humidity screen, within the calorimeter, and to apply orthogonal analytical techniques to gain a more informed understanding of why these SDDs formulated with HPMCAS-M demonstrated such different physical stability. Isothermal calorimetry (thermal activity monitor, TAM) was employed as a primary stress screen wherein the SDD formulations were monitored for 3 days at 37 °C 100% RH for signs of phase separation and possible crystallization of API. Powder X-ray diffraction (pXRD), modulated differential scanning calorimetry (mDSC), Fourier transform infrared spectroscopy (FTIR), and solid state nuclear magnetic resonance (ssNMR) were all used to examine formulated SDDs and neat amorphous drug. 452 SDDs formulated at 30% (wt/wt %) or less did not show phase separation behavior upon exposure to 37 °C 100% RH for 3 days. 034 SDD formulations from 10 through 50% (wt/wt %) all demonstrated thermal traces consistent with exothermic phase separation events over 3 days at 37 °C 100% RH in the TAM. However, only the 15, 30, and 50% containing 034 samples showed pXRD patterns consistent with crystalline material in post-TAM samples. Isothermal calorimetry is a useful screening tool to probe robust SDD physical performance and help investigate the level of drug polymer miscibility under a humid stress. Orthogonal analytical techniques such as pXRD, ssNMR, and FTIR were key in this SDD formulation screening to gain physical understanding and confirm or refute whether physical changes occur during the observed thermal events characterized by the calorimetric screening experiments.
Huang, Xiang-Ying; Yu, Shuang-Qing; Cheng, Zhan; Ye, Jing-Rong; Xu, Ke; Feng, Xia; Zeng, Yi
2013-04-01
To establish a simple and practical method for screening of Env-specific monoclonal antibodies from HIV-1 infected individuals. Human B cells were purified by negative sorting from PBMCs and memory B cells were further enriched using anti-CD27 microbeads. Gp120 antigen labbled with biotin was incubated with memory B cells to specifically bind IgG on cells membrane. The memory B cells expressing the Env-specific antibody were harvested by magnetic beads separating, counted and diluted to the level of single cell in each PCR well that loading with catch buffer containing RNase inhibitor to get RNAs. The antibody genes were amplified by single cell RT-PCR and nested PCR, cloned into eukaryotic expression vectors and transfected into 293T cells. The binding activity of recombinant antibodies to Env were tested by ELISA. Three monocolonal Env-specific antibodies were isolated from one HIV-1 infected individual. We can obtain Env-specific antibody by biotin labbled antigen, magnetic beads separating technique coupled with single cell RT-PCR and expression cloning.
Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.
2016-01-01
BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588
Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J
2016-03-15
New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.
Wang, Jing; Shi, Dongfang; Zheng, Meizhu; Ma, Bing; Cui, Jing; Liu, Chunming; Liu, Chengyu
2017-11-01
Natural products have become one of the most important resources for discovering novel xanthine oxidase inhibitors, which are commonly employed in the treatment of hyperuricemia and gout. However, to date, few reports exist regarding the use of monoterpene glycosides as xanthine oxidase inhibitors. Thus, we herein report the use of ultrafiltration coupled with liquid chromatography in the screening of monoterpene glycoside xanthine oxidase inhibitors from the extract of Paeonia lactiflora (P. lactiflora), and both high-performance counter-current chromatography and medium-pressure liquid chromatography were employed to separate the main constituents. Furthermore, the xanthine oxidase inhibitory activities and the mechanisms of inhibition of the isolated compounds were evaluated using a multi-mode microplate reader by Molecular Devices. As a result, three monoterpene glycosides were separated by combined high-performance counter-current chromatography and medium-pressure liquid chromatography in purities of 90.4, 98.0, and 86.3%, as determined by liquid chromatography. These three compounds were identified as albiflorin, paeoniflorin, and 1-O-β-ᴅ-glucopyranosyl-8-O-benzoylpaeonisuffrone by electrospray ionization tandem mass spectrometry, and albiflorin and paeoniflorin were screened as potential xanthine oxidase inhibitors by ultrafiltration with liquid chromatography. The evaluation results of xanthine oxidase inhibitory activity corresponded with the screening results, as only albiflorin and paeoniflorin exhibited xanthine oxidase inhibitory activity. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The Child Dissociative Checklist: Preliminary Findings of a Screening Measure.
ERIC Educational Resources Information Center
Wherry, Jeffrey N.; And Others
1994-01-01
Reports on the use of a screening instrument for dissociative behaviors in two separate but related studies. Results of a concurrent validity study between the Child Dissociative Checklist (CDC) and the Child Behavior Checklist indicate significant, positive correlations. A second study found that parent-completed CDC scores differentiate between…
Should Screening for Depression among Children and Adolescents Be Demedicalized?
ERIC Educational Resources Information Center
Horwitz, Allan V.; Wakefield, Jerome C.
2009-01-01
The criteria for diagnosing depressive disorders fails to place the symptoms of intense sadness in the context of major losses in life, and separating normal sadness from depressive disorder among adolescents is especially difficult. Suggested modifications to the screening of suicidal ideation among adolescents are also presented.
Richardson, Lyndsay Ann; El-Zein, Mariam; Ramanakumar, Agnihotram V; Ratnam, Samuel; Sangwa-Lugoma, Ghislain; Longatto-Filho, Adhemar; Cardoso, Marly Augusto; Coutlée, Francois; Franco, Eduardo L
2015-12-01
Knowledge of cervical human papillomavirus (HPV) status might influence a cytotechnician's assessment of cellular abnormalities. The authors compared original cytotechnicians' Papanicolaou (Pap) readings for which HPV status was concealed with Pap rereads for which HPV status was revealed separately for 3 screening populations. Previously collected cervical Pap smears and clinical data were obtained from the Canadian Cervical Cancer Screening Trial (study A), the Democratic Republic of Congo Community-Based Screening Study (study B), and the Brazilian Investigation into Nutrition and Cervical Cancer Prevention (study C). Smears were reread with knowledge of HPV status for all HPV-positive women as well as a sample of HPV-negative women. Diagnostic performance of Pap cytology was compared between original readings and rereads. A total of 1767 Pap tests were reread. Among 915 rereads for HPV-positive women, the contrast between "revealed" and "concealed" Pap readings demonstrated revisions from negative to positive results for 109 women (cutoff was atypical squamous cells of undetermined significance or worse) and 124 women (cutoff was low-grade squamous intraepithelial lesions [LSIL] or worse). For a disease threshold of cervical intraepithelial neoplasia of grade 2 or worse, specificity significantly declined at the atypical squamous cells of undetermined significance cutoff for studies A (86.6% to 75.3%) and C (42.5% to 15.5%), and at the LSIL cutoff for study C (61.9% to 37.6%). Sensitivity remained nearly unchanged between readings, except in study C, in which reread performance was superior (91.3% vs 71.9% for the LSIL cutoff). A reduction in the diagnostic accuracy of Pap cytology was observed when revealing patients' cervical HPV status, possibly due to a heightened awareness of potential abnormalities, which led to more false-positive results. © 2015 American Cancer Society.
Assessment of nucleosides as putative tumor biomarkers in prostate cancer screening by CE-UV.
Buzatto, Adriana Zardini; de Oliveira Silva, Mariana; Poppi, Ronei Jesus; Simionato, Ana Valéria Colnaghi
2017-05-01
Cancer is responsible for millions of deaths worldwide, but most base diseases may be cured if detected early. Screening tests may be used to identify early-stage malignant neoplasms. However, the major screening tool for prostate cancer, the prostate-specific antigen test, has unsuitable sensitivity. Since cancer cells may affect the pattern of consumption and excretion of nucleosides, such biomolecules are putative biomarkers that can be used for diagnosis and treatment evaluation. Using a previously validated method for the analysis of nucleosides in blood serum by capillary electrophoresis with UV-vis spectroscopy detection, we investigated 60 samples from healthy individuals and 42 samples from prostate cancer patients. The concentrations of nucleosides in both groups were compared and a multivariate partial least squares-discriminant analysis classification model was optimized for prediction of prostate cancer. The validation of the model with an independent sample set resulted in the correct classification of 82.4% of the samples, with sensitivity of 90.5% and specificity of 76.7%. A significant downregulation of 5-methyluridine and inosine was observed, which can be indicative of the carcinogenic process. Therefore, such analytes are potential candidates for prostate cancer screening. Graphical Abstract Separation of the studied nucleosides and the internal standard 8-Bromoguanosine by CE-UV (a); classification of the external validation samples (30 from healthy volunteers and 21 from prostate cancer patients) by the developed Partial Least Square - Discriminant Analysis (PLS-DA) model with accuracy of 82.4% (b); Receiver Operating Characteristics (ROC) curve (c); and Variable Importance in the Projection (VIP) values for the studied nucleosides (d). A significant down-regulation of 5- methyluridine (5mU) and inosine (I) was observed, which can be indicative of the presence of prostate tumors.
Harte, Philip T.; Flanagan, Sarah M.
2011-01-01
A new tool called ESASS (Enhanced Screen Auger Sampling System) was developed by the U.S. Geological Survey. The use of ESASS, because of its unique U.S. patent design (U.S. patent no. 7,631,705 B1), allows for the collection of representative, depth-specific groundwater samples (vertical profiling) in a quick and efficient manner using a 0.305-m long screen auger during hollow-stem auger drilling. With ESASS, the water column in the flights above the screen auger is separated from the water in the screen auger by a specially designed removable plug and collar. The tool fits inside an auger of standard inner diameter (82.55 mm). The novel design of the system constituted by the plug, collar, and A-rod allows the plug to be retrieved using conventional drilling A-rods. After retrieval, standard-diameter (50.8 mm) observation wells can be installed within the hollow-stem augers. Testing of ESASS was conducted at one waste-disposal site with tetrachloroethylene (PCE) contamination and at two reference sites with no known waste-disposal history. All three sites have similar geology and are underlain by glacial, stratified-drift deposits. For the applications tested, ESASS proved to be a useful tool in vertical profiling of groundwater quality. At the waste site, PCE concentrations measured with ESASS profiling at several depths were comparable (relative percent difference <25%) to PCE concentrations sampled from wells. Vertical profiling with ESASS at the reference sites illustrated the vertical resolution achievable in the profile system; shallow groundwater quality varied by a factor of five in concentration of some constituents (nitrate and nitrite) over short (0.61 m) distances.
Harte, P.T.; Flanagan, S.M.
2011-01-01
A new tool called ESASS (Enhanced Screen Auger Sampling System) was developed by the U.S. Geological Survey. The use of ESASS, because of its unique U.S. patent design (U.S. patent no. 7,631,705 B1), allows for the collection of representative, depth-specific groundwater samples (vertical profiling) in a quick and efficient manner using a 0.305-m long screen auger during hollow-stem auger drilling. With ESASS, the water column in the flights above the screen auger is separated from the water in the screen auger by a specially designed removable plug and collar. The tool fits inside an auger of standard inner diameter (82.55 mm). The novel design of the system constituted by the plug, collar, and A-rod allows the plug to be retrieved using conventional drilling A-rods. After retrieval, standard-diameter (50.8 mm) observation wells can be installed within the hollow-stem augers. Testing of ESASS was conducted at one waste-disposal site with tetrachloroethylene (PCE) contamination and at two reference sites with no known waste-disposal history. All three sites have similar geology and are underlain by glacial, stratified-drift deposits. For the applications tested, ESASS proved to be a useful tool in vertical profiling of groundwater quality. At the waste site, PCE concentrations measured with ESASS profiling at several depths were comparable (relative percent difference <25%) to PCE concentrations sampled from wells. Vertical profiling with ESASS at the reference sites illustrated the vertical resolution achievable in the profile system; shallow groundwater quality varied by a factor of five in concentration of some constituents (nitrate and nitrite) over short (0.61 m) distances. Ground Water Monitoring & Remediation ?? 2011, National Ground Water Association. No claim to original US government works.
THE INTRA- AND INTER-RATER RELIABILITY OF THE SOCCER INJURY MOVEMENT SCREEN (SIMS).
McCunn, Robert; Aus der Fünten, Karen; Govus, Andrew; Julian, Ross; Schimpchen, Jan; Meyer, Tim
2017-02-01
The growing volume of movement screening research reveals a belief among practitioners and researchers alike that movement quality may have an association with injury risk. However, existing movement screening tools have not considered the sport-specific movement and injury patterns relevant to soccer. The present study introduces the Soccer Injury Movement Screen (SIMS), which has been designed specifically for use within soccer. Furthermore, the purpose of the present study was to assess the intra- and inter-rater reliability of the SIMS and determine its suitability for use in further research. The study utilized a test-retest design to discern reliablility. Twenty-five (11 males, 14 females) healthy, recreationally active university students (age 25.5 ± 4.0 years, height 171 ± 9 cm, weight 64.7 ± 12.6 kg) agreed to participate. The SIMS contains five sub-tests: the anterior reach, single-leg deadlift, in-line lunge, single-leg hop for distance and tuck jump. Each movement was scored out of 10 points and summed to produce a composite score out of 50. The anterior reach and single-leg hop for distance were scored in real-time while the remaining tests were filmed and scored retrospectively. Three raters conducted the SIMS with each participant on three occasions separated by an average of three and a half days (minimum one day, maximum seven days). Rater 1 re-scored the filmed movements for all participants on all occasions six months later to establish the 'pure' intra-rater (intra-occasion) reliability for those movements. Intraclass correlation coefficient (ICC) values for intra- and inter-rater composite score reliability ranged from 0.66-0.72 and 0.79-0.86 respectively. Weighted kappa values representing the intra- and inter-rater reliability of the individual sub-tests ranged from 0.35-0.91 indicating fair to almost perfect agreement. Establishing the reliability of the SIMS is a prerequisite for further research seeking to investigate the relationship between test score and subsequent injury. The present results indicate acceptable reliability for this purpose; however, room for further development of the intra-rater reliability exists for some of the individual sub-tests. 2b.
THE INTRA- AND INTER-RATER RELIABILITY OF THE SOCCER INJURY MOVEMENT SCREEN (SIMS)
aus der Fünten, Karen; Govus, Andrew; Julian, Ross; Schimpchen, Jan; Meyer, Tim
2017-01-01
Background/purpose The growing volume of movement screening research reveals a belief among practitioners and researchers alike that movement quality may have an association with injury risk. However, existing movement screening tools have not considered the sport-specific movement and injury patterns relevant to soccer. The present study introduces the Soccer Injury Movement Screen (SIMS), which has been designed specifically for use within soccer. Furthermore, the purpose of the present study was to assess the intra- and inter-rater reliability of the SIMS and determine its suitability for use in further research. Methods The study utilized a test-retest design to discern reliablility. Twenty-five (11 males, 14 females) healthy, recreationally active university students (age 25.5 ± 4.0 years, height 171 ± 9 cm, weight 64.7 ± 12.6 kg) agreed to participate. The SIMS contains five sub-tests: the anterior reach, single-leg deadlift, in-line lunge, single-leg hop for distance and tuck jump. Each movement was scored out of 10 points and summed to produce a composite score out of 50. The anterior reach and single-leg hop for distance were scored in real-time while the remaining tests were filmed and scored retrospectively. Three raters conducted the SIMS with each participant on three occasions separated by an average of three and a half days (minimum one day, maximum seven days). Rater 1 re-scored the filmed movements for all participants on all occasions six months later to establish the ‘pure’ intra-rater (intra-occasion) reliability for those movements. Results Intraclass correlation coefficient (ICC) values for intra- and inter-rater composite score reliability ranged from 0.66-0.72 and 0.79-0.86 respectively. Weighted kappa values representing the intra- and inter-rater reliability of the individual sub-tests ranged from 0.35-0.91 indicating fair to almost perfect agreement. Conclusions Establishing the reliability of the SIMS is a prerequisite for further research seeking to investigate the relationship between test score and subsequent injury. The present results indicate acceptable reliability for this purpose; however, room for further development of the intra-rater reliability exists for some of the individual sub-tests. Level of evidence 2b PMID:28217416
Peeters, Bart; Geerts, Inge; Van Mullem, Mia; Micalessi, Isabel; Saegeman, Veroniek; Moerman, Jan
2016-05-01
Many hospitals opt for early postnatal discharge of newborns with a potential risk of readmission for neonatal hyperbilirubinemia. Assays/algorithms with the possibility to improve prediction of significant neonatal hyperbilirubinemia are needed to optimize screening protocols and safe discharge of neonates. This study investigated the predictive value of umbilical cord blood (UCB) testing for significant hyperbilirubinemia. Neonatal UCB bilirubin, UCB direct antiglobulin test (DAT), and blood group were determined, as well as the maternal blood group and the red blood cell antibody status. Moreover, in newborns with clinically apparent jaundice after visual assessment, plasma total bilirubin (TB) was measured. Clinical factors positively associated with UCB bilirubin were ABO incompatibility, positive DAT, presence of maternal red cell antibodies, alarming visual assessment and significant hyperbilirubinemia in the first 6 days of life. UCB bilirubin performed clinically well with an area under the receiver-operating characteristic curve (AUC) of 0.82 (95 % CI 0.80-0.84). The combined UCB bilirubin, DAT, and blood group analysis outperformed results of these parameters considered separately to detect significant hyperbilirubinemia and correlated exponentially with hyperbilirubinemia post-test probability. Post-test probabilities for neonatal hyperbilirubinemia can be calculated using exponential functions defined by UCB bilirubin, DAT, and ABO compatibility results. • The diagnostic value of the triad umbilical cord blood bilirubin measurement, direct antiglobulin testing and blood group analysis for neonatal hyperbilirubinemia remains unclear in literature. • Currently no guideline recommends screening for hyperbilirubinemia using umbilical cord blood. What is New: • Post-test probability for hyperbilirubinemia correlated exponentially with umbilical cord blood bilirubin in different risk groups defined by direct antiglobulin test and ABO blood group compatibility results. • Exponential functions can be used to calculate hyperbilirubinemia probability.
ZEBRAFISH AS AN IN VIVO MODEL FOR SUSTAINABLE CHEMICAL DESIGN.
Noyes, Pamela D; Garcia, Gloria R; Tanguay, Robert L
2016-12-21
Heightened public awareness about the many thousands of chemicals in use and present as persistent contaminants in the environment has increased the demand for safer chemicals and more rigorous toxicity testing. There is a growing recognition that the use of traditional test models and empirical approaches is impractical for screening for toxicity the many thousands of chemicals in the environment and the hundreds of new chemistries introduced each year. These realities coupled with the green chemistry movement have prompted efforts to implement more predictive-based approaches to evaluate chemical toxicity early in product development. While used for many years in environmental toxicology and biomedicine, zebrafish use has accelerated more recently in genetic toxicology, high throughput screening (HTS), and behavioral testing. This review describes major advances in these testing methods that have positioned the zebrafish as a highly applicable model in chemical safety evaluations and sustainable chemistry efforts. Many toxic responses have been shown to be shared among fish and mammals owing to their generally well-conserved development, cellular networks, and organ systems. These shared responses have been observed for chemicals that impair endocrine functioning, development, and reproduction, as well as those that elicit cardiotoxicity and carcinogenicity, among other diseases. HTS technologies with zebrafish enable screening large chemical libraries for bioactivity that provide opportunities for testing early in product development. A compelling attribute of the zebrafish centers on being able to characterize toxicity mechanisms across multiple levels of biological organization from the genome to receptor interactions and cellular processes leading to phenotypic changes such as developmental malformations. Finally, there is a growing recognition of the links between human and wildlife health and the need for approaches that allow for assessment of real world multi-chemical exposures. The zebrafish is poised to be an important model in bridging these two conventionally separate areas of toxicology and characterizing the biological effects of chemical mixtures that could augment its role in sustainable chemistry.
ZEBRAFISH AS AN IN VIVO MODEL FOR SUSTAINABLE CHEMICAL DESIGN
Noyes, Pamela D.; Garcia, Gloria R.; Tanguay, Robert L.
2016-01-01
Heightened public awareness about the many thousands of chemicals in use and present as persistent contaminants in the environment has increased the demand for safer chemicals and more rigorous toxicity testing. There is a growing recognition that the use of traditional test models and empirical approaches is impractical for screening for toxicity the many thousands of chemicals in the environment and the hundreds of new chemistries introduced each year. These realities coupled with the green chemistry movement have prompted efforts to implement more predictive-based approaches to evaluate chemical toxicity early in product development. While used for many years in environmental toxicology and biomedicine, zebrafish use has accelerated more recently in genetic toxicology, high throughput screening (HTS), and behavioral testing. This review describes major advances in these testing methods that have positioned the zebrafish as a highly applicable model in chemical safety evaluations and sustainable chemistry efforts. Many toxic responses have been shown to be shared among fish and mammals owing to their generally well-conserved development, cellular networks, and organ systems. These shared responses have been observed for chemicals that impair endocrine functioning, development, and reproduction, as well as those that elicit cardiotoxicity and carcinogenicity, among other diseases. HTS technologies with zebrafish enable screening large chemical libraries for bioactivity that provide opportunities for testing early in product development. A compelling attribute of the zebrafish centers on being able to characterize toxicity mechanisms across multiple levels of biological organization from the genome to receptor interactions and cellular processes leading to phenotypic changes such as developmental malformations. Finally, there is a growing recognition of the links between human and wildlife health and the need for approaches that allow for assessment of real world multi-chemical exposures. The zebrafish is poised to be an important model in bridging these two conventionally separate areas of toxicology and characterizing the biological effects of chemical mixtures that could augment its role in sustainable chemistry. PMID:28461781
Wiersum, Andrew D; Giovannangeli, Christophe; Vincent, Dominique; Bloch, Emily; Reinsch, Helge; Stock, Norbert; Lee, Ji Sun; Chang, Jong-San; Llewellyn, Philip L
2013-02-11
A high-throughput gas adsorption apparatus is presented for the evaluation of adsorbents of interest in gas storage and separation applications. This instrument is capable of measuring complete adsorption isotherms up to 40 bar on six samples in parallel using as little as 60 mg of material. Multiple adsorption cycles can be carried out and four gases can be used sequentially, giving as many as 24 adsorption isotherms in 24 h. The apparatus has been used to investigate the effect of metal center (MIL-100) and functional groups (CAU-10) on the adsorption of N(2), CO(2), and light hydrocarbons on MOFs. This demonstrates how it can serve to evaluate sample quality and adsorption reversibility, to determine optimum activation conditions and to estimate separation properties. As such it is a useful tool for the screening of novel adsorbents for different applications in gas separation, providing significant time savings in identifying potentially interesting materials.
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
Uptake of prenatal diagnostic testing and the effectiveness of prenatal screening for Down syndrome.
Jaques, Alice M; Collins, Veronica R; Muggli, Evelyne E; Amor, David J; Francis, Ivan; Sheffield, Leslie J; Halliday, Jane L
2010-06-01
To map prenatal screening and diagnostic testing pathways in Victorian pregnant women during 2003 to 2004; measure the impact of prenatal diagnostic testing uptake on the effectiveness of prenatal screening for Down syndrome; and assess factors influencing uptake of diagnostic testing following screening. State-wide data collections of prenatal screening and diagnostic tests were linked to all Victorian births and pregnancy terminations for birth defects. Overall, 52% of women had a prenatal test (65 692/126 305); screening (44.9%), diagnostic testing (3.9%), or both (3.2%). Uptake of diagnostic testing was 71.4% (2390/3349) after an increased risk screen result, and 2.5% (1381/54 286) after a low risk result. Variation in uptake of diagnostic testing reduced the effectiveness of the screening program by 11.2%: from 87.4% (sensitivity - 125/143) to 76.2% (prenatal diagnoses of Down syndrome - 109/143). In both the increased and low risk groups, uptake was influenced by absolute numerical risk, as well as by the change in numerical risk from a priori risk. This comprehensive follow-up demonstrates clearly that numerical risk is being used to aid in decision making about confirmatory diagnostic testing. Collectively, these fundamental individual decisions will impact on the overall effectiveness of screening programmes for Down syndrome.
Early Adoption of a Multitarget Stool DNA Test for Colorectal Cancer Screening.
Finney Rutten, Lila J; Jacobson, Robert M; Wilson, Patrick M; Jacobson, Debra J; Fan, Chun; Kisiel, John B; Sweetser, Seth; Tulledge-Scheitel, Sidna M; St Sauver, Jennifer L
2017-05-01
To characterize early adoption of a novel multitarget stool DNA (MT-sDNA) screening test for colorectal cancer (CRC) screening and to test the hypothesis that adoption differs by demographic characteristics and prior CRC screening behavior and proceeds predictably over time. We used the Rochester Epidemiology Project research infrastructure to assess the use of the MT-sDNA screening test in adults aged 50 to 75 years living in Olmsted County, Minnesota, in 2014 and identified 27,147 individuals eligible or due for screening colonoscopy from November 1, 2014, through November 30, 2015. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of the MT-sDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior CRC screening behavior. Overall, 2193 (8.1%) and 974 (3.6%) individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior CRC screening behavior were significantly and independently associated with MT-sDNA screening use compared with colonoscopy use after adjustment for all other variables (P<.05 for all). The rates of adoption of MT-sDNA screening increased over time and were highest in those aged 50 to 54 years, women, whites, and those who had a history of screening. The use of the MT-sDNA screening test varied predictably by insurance coverage. The rates of colonoscopy decreased over time, whereas overall CRC screening rates remained steady. The results of the present study are generally consistent with predictions derived from prior research and the diffusion of innovation framework, pointing to increasing use of the new screening test over time and early adoption by younger patients, women, whites, and those with prior CRC screening. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
2013-01-01
Background Emergency department (ED) patients comprise a high-risk population for alcohol misuse and sexual risk for HIV. In order to design future interventions to increase HIV screening uptake, we examined the interrelationship among alcohol misuse, sexual risk for HIV and HIV screening uptake among these patients. Methods A random sample of 18-64-year-old English- or Spanish-speaking patients at two EDs during July-August 2009 completed a self-administered questionnaire about their alcohol use using the Alcohol Use Questionnaire, the Alcohol Use Disorders Identification Test (AUDIT), and the HIV Sexual Risk Questionnaire. Study participants were offered a rapid HIV test after completing the questionnaires. Binging (≥ five drinks/occasion for men, ≥ four drinks for women) was assessed and sex-specific alcohol misuse severity levels (low-risk, harmful, hazardous, dependence) were calculated using AUDIT scores. Analyses were limited to participants who had sexual intercourse in the past 12 months. Multivariable logistic regression was used to assess the associations between HIV screening uptake and (1) alcohol misuse, (2) sexual risk for HIV, and (3) the intersection of HIV sexual risk and alcohol misuse. Adjusted odds ratios (AORs) with 95% confidence intervals (CIs) were estimated. All models were adjusted for patient demographic characteristics and separate models for men and women were constructed. Results Of 524 participants (55.0% female), 58.4% identified as white, non-Hispanic, and 72% reported previous HIV testing. Approximately 75% of participants reported drinking alcohol within the past 30 days and 74.5% of men and 59.6% of women reported binge drinking. A relationship was found between reported sexual risk for HIV and alcohol use among men (AOR 3.31 [CI 1.51-7.24]) and women (AOR 2.78 [CI 1.48-5.23]). Women who reported binge drinking were more likely to have higher reported sexual risk for HIV (AOR 2.55 [CI 1.40-4.64]) compared to women who do not report binge drinking. HIV screening uptake was not higher among those with greater alcohol misuse and sexual risk among men or women. Conclusions The apparent disconnection between HIV screening uptake and alcohol misuse and sexual risk for HIV among ED patients in this study is concerning. Brief interventions emphasizing these associations should be evaluated to reduce alcohol misuse and sexual risk and increase the uptake of ED HIV screening. PMID:23721108
Mandal, Shreya; Patra, Arpita; Samanta, Animesh; Roy, Suchismita; Mandal, Arpita; Mahapatra, Tapasi Das; Pradhan, Shrabani; Das, Koushik; Nandi, Dilip Kumar
2013-01-01
Objective To investigate phytochemical screening, antimicrobial activity and qualitative thin layer chromatographic separation of flavonoid components, antioxidant activity and total flavonoid compound of Terminalia arjuna. Methods For phytochemical screening, some common and available standard tests were done. Antimicrobial bioassay was done through agar well diffusion method. Detection of antioxidant activity and flavonoid compounds were done through thin layer chromatography. Total antioxidant activity was measured by 2, 2-diphenyl-1-picrylhydrazyl (DPPH) in colorimetric method. Aluminum chloride colorimetric method was used for total flavonoid determination. Results Phytochemical screening showed the active compounds presence in high concentration, such as phytosterol, lactones, flavonoids, phenolic compounds and tannins and glycosides. The antimicrobial activity of extract showed that greater inhibition zone against Gram negative bacteria than Gram positive bacteria. This methanolic extract showed a promising antioxidant activity, as absorption of DPPH redicles decreased in DPPH free radical scavenging assay. Flavonoids components having antioxidant property present in the methanol extract at a level of 199.00 mg quercetin equivalent/g of dried methanol extract in colorimetric method. Conclusions The Terminalia arjuna bark extract revealed the presence of bio-active constituents which are known to exhibit medicinal as well as physiological activities. PMID:24093787
Early Adoption of a Multi-target Stool DNA Test for Colorectal Cancer Screening
Finney Rutten, Lila J.; Jacobson, Robert M.; Wilson, Patrick M.; Jacobson, Debra J.; Fan, Chun; Kisiel, John B.; Sweetser, Seth R.; Tulledge-Scheitel, Sidna M.; St. Sauver, Jennifer L.
2017-01-01
Objective To characterize early adoption of a novelmulti-target stool deoxyribonucleic acid (MTsDNA) screening test for colorectal cancer (CRC) and test the hypothesis that adoption differs by demographic characteristics, prior CRC screening behavior, and proceeds predictably over time. Patients and Methods We used the Rochester Epidemiology Project infrastructure to assess MTsDNA screening test use among adults aged 50–75 years, and identified 27,147 individuals eligible/due for screening colonoscopy from November 1, 2014 through November 30, 2015, and living in Olmsted County, Minnesota in2014. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of MTsDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior screening behavior. Results Overall, 2,193 (8.1%) and 974 (3.6%) of individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior screening were significantly and independently associated with MT-sDNA screening use compared to colonoscopy use after adjustment for all other variables. Rates of adoption of MTsDNA screening increased over time and were highest among those aged 50–54 years, females, whites, and had a prior history of screening. MT-sDNA screening use varied predictably by insurance coverage. Rates of colonoscopy decreased over time, while overall CRC screening rates remained steady. Conclusion Our results are generally consistent with predictions derived from prior research and Diffusion of Innovation framework, pointing to increasing use of the new screening test over time, and early adoption by younger patients, females, whites and those with prior CRC screening. PMID:28473037
Becker, Elizabeth A.; Griffith, Derek M.; West, Brady T.; Janz, Nancy K.; Resnicow, Ken; Morris, Arden M.
2015-01-01
Background Screening and post-symptomatic diagnostic testing are often conflated in cancer screening surveillance research. We examined the error in estimated colorectal cancer (CRC) screening prevalence due to the conflation of screening and diagnostic testing. Methods Using data from the 2008 National Health Interview Survey, we compared weighted prevalence estimates of the use of all testing (screening and diagnostic) and screening in at-risk adults, and calculated the overestimation of screening prevalence across socio-demographic groups. Results The population screening prevalence was overestimated by 23.3%, and the level of overestimation varied widely across socio-demographic groups (median 22.6%, mean 24.8%). The highest levels of overestimation were in non-Hispanic White females (27.4%), adults ages 50–54 (32.0%), and those with the highest socioeconomic vulnerability (low educational attainment (31.3%), low poverty ratio (32.5%), no usual source of health care (54.4%) and not insured (51.6%)) (all p-values < 0.001). Conclusions When the impetus for testing was not included, CRC screening prevalence was overestimated, and patterns of overestimation often aligned with social and economic vulnerability. These results are of concern to researchers who utilize survey data from the Behavioral Risk Factor Surveillance System (BRFSS) to assess cancer screening behaviors, as it is currently not designed to distinguish diagnostic testing from screening. Impact Surveillance research in cancer screening that does not consider the impetus for testing risks measurement error of screening prevalence, impeding progress toward improving population health. Ultimately, in order to craft relevant screening benchmarks and interventions, we must look beyond ‘what’ and ‘when’ and include ‘why.’ PMID:26491056
... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
Glucose screening tests during pregnancy
Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... first step, you will have a glucose screening test: You DO NOT need to prepare or change ...
Resistance of Grape Rootstocks to Plant-parasitic Nematodes.
Ferris, H; Zheng, L; Walker, M A
2012-12-01
Candidate grape rootstocks were selected through a rigorous screening program initiated with important sources of resistance to Meloidogyne pathotypes and to Xiphinema index in Muscadinia rotundifolia and Vitis species native to North America. Based on their rooting capability and horticultural characteristics, 200 candidates were selected from 5,000 progeny of multiple crosses between commercial grape rootstocks and wild grape species that exhibited resistance to nematodes. After a 15-year screening process, 13 selections emerged with either almost complete or complete combined resistance to M. incognita Race 3, M. incognita pathotype Harmony C, M. arenaria pathotype Harmony A, and X. index, important nematode pests of grapevines. Durability of this broad resistance was tested by challenging the selections with the target nematodes in combination and with the target nematodes in combinations with species not included in the screening process. Durability of resistance of the candidate rootstocks was also tested by exposure to the nematode communities of infested field soils from different locations. Breadth of resistance was determined on the basis of their host status to non-target nematodes, including Mesocriconema xenoplax, Pratylenchus vulnus, Tylenchulus semipenetrans and Paratylenchus hamatus. After a total of 204 separate trials, the rootstocks were released to the grape industry as UCD GRN1, UCD GRN2, UCD GRN3, UCD GRN4, and UCD GRN5. We provide a compilation of current knowledge of the host status of these five newly released rootstocks and of 27 other rootstock cultivars to plant-parasitic nematodes.
Resistance of Grape Rootstocks to Plant-parasitic Nematodes
Ferris, H.; Zheng, L.; Walker, M. A.
2012-01-01
Candidate grape rootstocks were selected through a rigorous screening program initiated with important sources of resistance to Meloidogyne pathotypes and to Xiphinema index in Muscadinia rotundifolia and Vitis species native to North America. Based on their rooting capability and horticultural characteristics, 200 candidates were selected from 5,000 progeny of multiple crosses between commercial grape rootstocks and wild grape species that exhibited resistance to nematodes. After a 15-year screening process, 13 selections emerged with either almost complete or complete combined resistance to M. incognita Race 3, M. incognita pathotype Harmony C, M. arenaria pathotype Harmony A, and X. index, important nematode pests of grapevines. Durability of this broad resistance was tested by challenging the selections with the target nematodes in combination and with the target nematodes in combinations with species not included in the screening process. Durability of resistance of the candidate rootstocks was also tested by exposure to the nematode communities of infested field soils from different locations. Breadth of resistance was determined on the basis of their host status to non-target nematodes, including Mesocriconema xenoplax, Pratylenchus vulnus, Tylenchulus semipenetrans and Paratylenchus hamatus. After a total of 204 separate trials, the rootstocks were released to the grape industry as UCD GRN1, UCD GRN2, UCD GRN3, UCD GRN4, and UCD GRN5. We provide a compilation of current knowledge of the host status of these five newly released rootstocks and of 27 other rootstock cultivars to plant-parasitic nematodes. PMID:23482972
Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J
2017-06-01
The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Screening tests for aphasia in patients with stroke: a systematic review.
El Hachioui, Hanane; Visch-Brink, Evy G; de Lau, Lonneke M L; van de Sandt-Koenderman, Mieke W M E; Nouwens, Femke; Koudstaal, Peter J; Dippel, Diederik W J
2017-02-01
Aphasia has a large impact on the quality of life and adds significantly to the costs of stroke care. Early recognition of aphasia in stroke patients is important for prognostication and well-timed treatment planning. We aimed to identify available screening tests for differentiating between aphasic and non-aphasic stroke patients, and to evaluate test accuracy, reliability, and feasibility. We searched PubMed, EMbase, Web of Science, and PsycINFO for published studies on screening tests aimed at assessing aphasia in stroke patients. The reference lists of the selected articles were scanned, and several experts were contacted to detect additional references. Of each screening test, we estimated the sensitivity, specificity, likelihood ratio of a positive test, likelihood ratio of a negative test, and diagnostic odds ratio (DOR), and rated the degree of bias of the validation method. We included ten studies evaluating eight screening tests. There was a large variation across studies regarding sample size, patient characteristics, and reference tests used for validation. Many papers failed to report on the consecutiveness of patient inclusion, time between aphasia onset and administration of the screening test, and blinding. Of the three studies that were rated as having an intermediate or low risk of bias, the DOR was highest for the Language Screening Test and ScreeLing. Several screening tools for aphasia in stroke are available, but many tests have not been verified properly. Methodologically sound validation studies of aphasia screening tests are needed to determine their usefulness in clinical practice.
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
Pap Testing Stages of Adoption among Cambodian Immigrants
Taylor, Victoria M.; Jackson, J. Carey; Yasui, Yutaka; Schwartz, Stephen M.; Kuniyuki, Alan; Fischer, Meredith; Tu, Shin-Ping
2006-01-01
Purpose We examined levels of Pap testing and factors associated with screening participation among Cambodian refugees. Methods A community-based, in-person survey was conducted in Seattle during late 1997 and early 1998. Interviews were completed by 413 women; the estimated response rate was 73%. We classified respondents into four Pap testing stages of adoption: precontemplation/contemplation (never screened), relapse (ever screened but did not plan to be screened in the future), action (ever screened and planned to be screened in the future), and maintenance (recently screened and planned to be screened in the future). Bivariate and multivariate techniques were used to examine various factors. Findings About one-quarter (24%) of the respondents has never been screened, and a further 22% had been screened but did not plan to obtain Pap tests in the future. Fifteen percent were in the action stage and 39% were in the maintenance stage. The following factors were independently associated with cervical cancer screening stages: previous physician recommendation; younger age; beliefs about Pap testing for post-menopausal women, screening for sexually inactive women, and regular checkups; provider ethnicity; prenatal care in the US; and problems finding interpreters. Conclusions Our findings confirm low Pap testing rates among Cambodian immigrants, and suggest that targeted interventions should be multifaceted. PMID:11567513
40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... toxicity screening test. 799.9355 Section 799.9355 Protection of Environment ENVIRONMENTAL PROTECTION... AND MIXTURE TESTING REQUIREMENTS Health Effects Test Guidelines § 799.9355 TSCA reproduction/developmental toxicity screening test. (a) Scope—(1) Applicability. This section is intended to meet testing...
40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... toxicity screening test. 799.9355 Section 799.9355 Protection of Environment ENVIRONMENTAL PROTECTION... AND MIXTURE TESTING REQUIREMENTS Health Effects Test Guidelines § 799.9355 TSCA reproduction/developmental toxicity screening test. (a) Scope—(1) Applicability. This section is intended to meet testing...
HPV primary cervical screening in England: Women's awareness and attitudes.
Patel, Hersha; Moss, Esther L; Sherman, Susan M
2018-03-09
Primary human papillomavirus (HPV) cervical screening is due to be implemented in England within the next 2 years; however, the acceptability of HPV testing as the primary screening test is unclear. This study explores women's awareness and attitudes toward HPV testing/screening. Qualitative interviews (semistructured and focus group) were conducted with 46 women (aged 25-65 years) from community and secondary care settings. Data were analyzed by using the inductive-framework method. Women were unaware that cervical screening currently includes HPV testing and lacked HPV-related knowledge. Emotions of shock, fear, and anxiety were reported upon receiving a positive HPV result. For women in long-term relationships, the realization that HPV is a sexually transmitted infection was seen as a barrier to primary HPV testing. Knowledge that HPV testing is a screening test to prevent cervical cancer did not change their attitudes. Women debated the need for continued screening following a negative result. Women feared judgment by the community if they participated with primary HPV screening because they were being tested for a sexually transmitted infection, with the possible attendant perception that they had adopted a high-risk lifestyle in comparison to nonattenders. The acceptability of HPV testing may be a limiting factor in encouraging participation with screening in the future. Copyright © 2018 John Wiley & Sons, Ltd.
Risks of Skin Cancer Screening
... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
van der Linden, Helma; Austin, Tony; Talmon, Jan
2009-09-01
Future-proof EHR systems must be capable of interpreting information structures for medical concepts that were not available at the build-time of the system. The two-model approach of CEN 13606/openEHR using archetypes achieves this by separating generic clinical knowledge from domain-related knowledge. The presentation of this information can either itself be generic, or require design time awareness of the domain knowledge being employed. To develop a Graphical User Interface (GUI) that would be capable of displaying previously unencountered clinical data structures in a meaningful way. Through "reasoning by analogy" we defined an approach for the representation and implementation of "presentational knowledge". A proof-of-concept implementation was built to validate its implementability and to test for unanticipated issues. A two-model approach to specifying and generating a screen representation for archetype-based information, inspired by the two-model approach of archetypes, was developed. There is a separation between software-related display knowledge and domain-related display knowledge and the toolkit is designed with the reuse of components in mind. The approach leads to a flexible GUI that can adapt not only to information structures that had not been predefined within the receiving system, but also to novel ways of displaying the information. We also found that, ideally, the openEHR Archetype Definition Language should receive minor adjustments to allow for generic binding.
Assari, Shervin; Dejman, Masoumeh; Neighbors, Harold W
2016-09-01
The aim of this study was to explore ethnic differences in the separate and additive effects of anxiety and depression on self-rated mental health (SRMH) of Blacks in the USA. With a cross-sectional design, we used data from a national household probability sample of African Americans (n = 3570) and Caribbean Blacks (n = 1621) who participated in the National Survey of American Life, 2001-2003. Demographic factors, socio-economic factors, 12-month general anxiety disorder (GAD) and major depressive disorder (MDD), and current SRMH were measured. In each ethnic group, three logistic regressions were used to assess the effects of GAD, MDD, and their combinations on SRMH. Among African Americans, GAD and MDD had separate effects on SRMH. Among Caribbean Blacks, only MDD but not GAD had separate effect on SRMH. Among African Americans, when the combined effects of GAD and MDD were tested, GAD but not MDD was associated with SRMH. The separate and additive effects of GAD and MDD on SRMH among Blacks depend on ethnicity. Although single-item SRMH measures are easy methods for the screening of mental health need, community-based programs that aim to meet the need for mental health services among Blacks in the USA should consider within-race ethnic differences in the applicability of such instruments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-08-01
In this project, in situ remediation technologies are being tested and evaluated for both source control and mass removal of dense, non-aqueous phase liquid (DNAPL) compounds in low permeability media (LPM). This effort is focused on chlorinated solvents (e.g., trichloroethylene and perchloroethylene) in the vadose and saturated zones of low permeability, massive deposits, and stratified deposits with inter-bedded clay lenses. The project includes technology evaluation and screening analyses and field-scale testing at both clean and contaminated sites in the US and Canada. Throughout this project, activities have been directed at understanding the processes that influence DNPAL compound migration and treatmentmore » in LPM and to assessing the operation and performance of the remediation technologies developed and tested. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.« less
Computational fluid dynamics (CFD) studies of a miniaturized dissolution system.
Frenning, G; Ahnfelt, E; Sjögren, E; Lennernäs, H
2017-04-15
Dissolution testing is an important tool that has applications ranging from fundamental studies of drug-release mechanisms to quality control of the final product. The rate of release of the drug from the delivery system is known to be affected by hydrodynamics. In this study we used computational fluid dynamics to simulate and investigate the hydrodynamics in a novel miniaturized dissolution method for parenteral formulations. The dissolution method is based on a rotating disc system and uses a rotating sample reservoir which is separated from the remaining dissolution medium by a nylon screen. Sample reservoirs of two sizes were investigated (SR6 and SR8) and the hydrodynamic studies were performed at rotation rates of 100, 200 and 400rpm. The overall fluid flow was similar for all investigated cases, with a lateral upward spiraling motion and central downward motion in the form of a vortex to and through the screen. The simulations indicated that the exchange of dissolution medium between the sample reservoir and the remaining release medium was rapid for typical screens, for which almost complete mixing would be expected to occur within less than one minute at 400rpm. The local hydrodynamic conditions in the sample reservoirs depended on their size; SR8 appeared to be relatively more affected than SR6 by the resistance to liquid flow resulting from the screen. Copyright © 2017 Elsevier B.V. All rights reserved.
Smith, David W; Tapsall, John W; Lum, Gary
2005-01-01
The Public Health Laboratory Network (PHLN) convened a workshop of Australian experts in Melbourne on 23 March 2005 to identify laboratory issues of relevance and suggest guidelines for use of nucleic acid detection tests (NADT) for diagnosis of gonorrhoea in Australia. The proceedings of that meeting were endorsed by the members of the PHLN and the Communicable Diseases Network of Australia. Given the present state of knowledge and experience of conditions currently existing in Australia, the following recommendations were made: Recommendation 1: Assays using detection of the cppB gene should not be used for either screening or supplemental assays. Recommendation 2: All in-house screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 3: All commercial screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 4: If a sample is positive in a screening assay but a suitable supplemental assay is negative, then the result should be reported as negative. Recommendation 5: Laboratories should ensure that the test combination they use would yield a positive predictive value of at least 90 per cent in a population with a prevalence of 1 per cent. Recommendation 6: For the purposes of test evaluation, as distinct from diagnostic testing, true positives be defined by meeting one or more of the following criteria: 1) culture positive using contemporary isolation and identification techniques; 2) positive result on NADTs directed to targets on three separate genes that are known to have discriminatory capacity; 3) sequencing of a gene known to separate gonococcal from non-gonococcal species. Recommendation 7: Inhibitor controls should be routinely included in all NADT. Recommendation 8: Cultures are the preferred test for samples from non-genital sites. If however it is necessary to perform a NADT, then more stringent criteria should be applied, and positive samples should meet the 'test evaluation' criteria for a 'true positive'. Recommendation 9: In order to properly assess the routine diagnostic system in Australia, the following quality assurance samples should be distributed in addition to the routine samples currently used: 1. cppB negative N. gonorrhoeae; 2. Non-gonococcal species known to cause false positive reactions: these should be dispatched both as a single species, as well as mixture with N. gonorrhoeae. In the latter circumstance, the non-gonococcal species should be present in 10-fold excess; 3. Urine samples: preferably a single patient sample, otherwise a spiked sample. 4. Validation panels should be made that include samples that are culture positive but PCR negative. True positive samples should also be made available. In addition, a process should be established for full phenotypic and genotypic characterisation of unidentified species that yield false positive results in NADT for gonococci. Recommendation 10: Strategies should be put in place to ensure that sufficient numbers of gonococcal isolates are obtained to allow reliable monitoring of antimicrobial resistance. Recommendation 11: Public health practitioners need to define the relevant populations that need to be targeted and identify any that require enhanced surveillance.
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening test for HBsAg); and (4) Hepatitis C (e.g., FDA licensed screening test for anti-HCV). (b) In the case... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
Optimizing Cognitive Load for Learning from Computer-Based Science Simulations
ERIC Educational Resources Information Center
Lee, Hyunjeong; Plass, Jan L.; Homer, Bruce D.
2006-01-01
How can cognitive load in visual displays of computer simulations be optimized? Middle-school chemistry students (N = 257) learned with a simulation of the ideal gas law. Visual complexity was manipulated by separating the display of the simulations in two screens (low complexity) or presenting all information on one screen (high complexity). The…
Are All Latinas the Same?: Perceived Breast Cancer Screening Barriers and Facilitative Conditions
ERIC Educational Resources Information Center
Buki, Lydia P.; Borrayo, Evelinn A.; Feigal, Benjamin M.; Carrillo, Iris Y.
2004-01-01
In this article, we examine perceived breast cancer screening barriers and facilitative conditions for immigrant women from Mexico, Puerto Rico, Cuba, El Salvador, and South America (N=58). Focus groups conducted separately with women of each ancestry were analyzed using grounded theory methods. Identified barriers comprise secrecy, lack of…
Comprehensive field screenings for whorl- and ear-feeding insect resistance in corn germplasm lines
USDA-ARS?s Scientific Manuscript database
A holistic approach to developing new corn germplasm that confers multiple insect resistance in various plant tissues at different growth stages was examined in two separate studies. The first study was the screening of eight corn germplasm lines for resistance whorl damage to fall armyworm [Spodop...
46 CFR 162.017-3 - Materials, construction, and workmanship.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-resistant wire mesh with a 1/2-inch corrosion-resistant separator on a single screen of 30×30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere. The net free area through the flame... are not acceptable. (e) Flame screens shall be made of corrosion-resistant wire. (f) Nonmetallic...
Ong, Jason J; Fu, Hongyun; Smith, M Kumi; Tucker, Joseph D
2018-05-01
Syphilis is an important sexually transmitted infection (STI). Despite inexpensive and effective treatment, few key populations receive syphilis testing. Innovative strategies are needed to increase syphilis testing among key populations. Areas covered: This scoping review focused on strategies to increase syphilis testing in key populations (men who have sex with men (MSM), sex workers, people who use drugs, transgender people, and incarcerated individuals). Expert commentary: We identified many promising syphilis testing strategies, particularly among MSM. These innovations are separated into diagnostic, clinic-based, and non-clinic based strategies. In terms of diagnostics, self-testing, dried blood spots, and point-of-care testing can decentralize syphilis testing. Effective syphilis self-testing pilots suggest the need for further attention and research. In terms of clinic-based strategies, modifying default clinical procedures can nudge physicians to more frequently recommend syphilis testing. In terms of non-clinic based strategies, venue-based screening (e.g. in correctional facilities, drug rehabilitation centres) and mobile testing units have been successfully implemented in a variety of settings. Integration of syphilis with HIV testing may facilitate implementation in settings where individuals have increased sexual risk. There is a strong need for further syphilis testing research and programs.
Wang, Jing; Zheng, Meizhu; Chen, Lina; Liu, Zhiqiang; Zhang, Yuchi; Liu, Chun-Ming; Liu, Shu
2016-11-01
Hydroxyl radicals are the most reactive free radical of human body, a strong contributor to tissue damage. In this study, liquid chromatography coupled to electrospray ionization mass spectrometry was applied to screen and identify hydroxyl radical scavengers from the total flavonoids of Ginkgo biloba leaves, and high-performance counter current chromatography was used to separate and isolate the active compounds. Furthermore, molecular devices were used to determine hydroxyl radical scavenging activities of the obtained hydroxyl radical scavengers and other flavonoids from G. biloba leaves. As a result, six compounds were screened as hydroxyl radical scavengers, but only three flavonoids, namely, rutin, cosmos glycosides and apigenin-7-O-Glu-4'-O-Rha, were isolated successfully from total flavonoids by high-performance counter current chromatography. The purities of the three obtained compounds were over 90%, respectively, as determined by liquid chromatography. Molecular devices with 96-well microplates evaluation indicated that the 50% scavenging concentration values of screened compounds were lower than that of other flavonoids, they performed greater hydroxyl radical scavenging activity, and the evaluation effects were consistent with the liquid chromatography with mass spectrometry screening results. Therefore, chromatography combined with molecular devices is a feasible and an efficient method for systematic screening, identification, isolation, and evaluation of bioactive components in mixture of botanical medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Halpern, Michael T; Romaire, Melissa A; Haber, Susan G; Tangka, Florence K; Sabatino, Susan A; Howard, David H
2014-10-01
Although state Medicaid programs cover cancer screening, Medicaid beneficiaries are less likely to be screened for cancer and are more likely to present with tumors of an advanced stage than are those with other insurance. The current study was performed to determine whether state Medicaid eligibility and reimbursement policies affect the receipt of breast, cervical, and colon cancer screening among Medicaid beneficiaries. Cross-sectional regression analyses of 2007 Medicaid data from 46 states and the District of Columbia were performed to examine associations between state-specific Medicaid reimbursement/eligibility policies and receipt of cancer screening. The study sample included individuals aged 21 years to 64 years who were enrolled in fee-for-service Medicaid for at least 4 months. Subsamples eligible for each screening test were: Papanicolaou test among 2,136,511 patients, mammography among 792,470 patients, colonoscopy among 769,729 patients, and fecal occult blood test among 753,868 patients. State-specific Medicaid variables included median screening test reimbursement, income/financial asset eligibility requirements, physician copayments, and frequency of eligibility renewal. Increases in screening test reimbursement demonstrated mixed associations (positive and negative) with the likelihood of receiving screening tests among Medicaid beneficiaries. In contrast, increased reimbursements for office visits were found to be positively associated with the odds of receiving all screening tests examined, including colonoscopy (odds ratio [OR], 1.07; 95% confidence interval [95% CI], 1.06-1.08), fecal occult blood test (OR, 1.09; 95% CI, 1.08-1.10), Papanicolaou test (OR, 1.02; 95% CI, 1.02-1.03), and mammography (OR, 1.02; 95% CI, 1.02-1.03). Effects of other state-specific Medicaid policies varied across the screening tests examined. Increased reimbursement for office visits was consistently associated with an increased likelihood of being screened for cancer, and may be an important policy tool for increasing screening among this vulnerable population. © 2014 American Cancer Society.
Cantor, Amy G; Pappas, Miranda; Daeges, Monica; Nelson, Heidi D
2016-06-07
Screening for syphilis infection is currently recommended for high-risk individuals, including those with previous syphilis infection, an infected sexual partner, HIV infection, or more than 4 sex partners in the preceding year. To update a 2004 systematic review of studies of syphilis screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews through October 2015 and Ovid MEDLINE (January 2004 to October 2015), with updated search through March 2016. English-language trials and observational studies of screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. One investigator abstracted data, a second checked data for accuracy, and 2 investigators independently assessed study quality using predefined criteria. Transmission of disease, including HIV; complications of syphilis; diagnostic accuracy; and harms of screening. No evidence was identified regarding the effectiveness of screening on clinical outcomes or the effectiveness of risk assessment instruments; the harms of screening; or the effectiveness of screening in average-risk, nonpregnant adolescents or adults or high-risk individuals other than men who have sex with men (MSM) or men who are HIV positive. Four non-US studies indicated higher rates of syphilis detection with screening every 3 months vs 6 or 12 months for early syphilis in HIV-positive men or MSM. For example, there was an increased proportion of asymptomatic, higher-risk MSM in Australia (n = 6789 consultations) receiving a diagnosis of early syphilis when tested every 3 months vs annually (53% vs 16%, P = .001), but no difference among low-risk MSM. Treponemal and nontreponemal tests were accurate in asymptomatic individuals (sensitivity >85%, specificity >91%) in 3 studies but required confirmatory testing. Reverse sequence testing with an initial automated treponemal test yielded more false reactive test results than with rapid plasma reagin in 2 studies, one with a low-prevalence US population (0.6% vs 0.0%, P = .03) and another in a higher-prevalence Canadian population (0.26% vs 0.13%). Screening HIV-positive men or MSM for syphilis every 3 months is associated with improved syphilis detection. Treponemal or nontreponemal tests are accurate screening tests but require confirmation. Research is needed on the effect of screening on clinical outcomes; effective screening strategies, including reverse sequence screening, in various patient populations; and harms of screening.
HIV and Syphilis Prevalence and Associated Risks in the Cameroonian Armed Forces.
Grillo, Michael; Tran, Bonnie Robin; Tamoufe, Ubald; Djoko, Cyrille F; Saylors, Karen; Woodland, Kelly; Wangmene, L T C; Macera, Caroline
2017-01-01
Continued surveillance of the HIV epidemic is critical to monitor changes in trends and risk behaviors. A 2005 study in the Cameroonian Armed Forces (CAF) found an HIV prevalence of 11.3% among male and female service members. The purpose of the current study is to determine the 5-year change in the HIV prevalence, estimate the prevalence of syphilis, and examine factors associated with infection in the CAF. Participants were male and female service members 18 years of age or older who were stationed at one of the 10 military garrisons selected for participation. The military garrisons included in this study were proportionally representative of the CAF by geographic region. Military companies and individuals within the selected garrisons were randomly chosen to participate in the study. Demographic and behavioral risk data were collected from September-November 2011 using personal interviews. Blood was collected for HIV and syphilis testing. Of 2,523 participants tested, 6.0% screened positive for HIV [includes 5.3% who screened positive for HIV only and 0.7% who screened positive for both HIV and syphilis], and 3.1% screened positive for syphilis only. Analyses examining risk factors associated with HIV/syphilis infection (i.e., infected with HIV, infected with syphilis, or co-infected with both HIV and syphilis) were restricted to 2,255 men who reported ever having sex. In a multivariate logistic regression model, the odds of testing positive for HIV/syphilis were higher among men who were separated, divorced, or widowed (adjusted odds ratio [AOR]=3.13, 95% confidence interval [CI]: 1.24-7.89), had sex with sex workers (AOR=1.64, 95% CI: 1.19-2.27), and reported a genital sore/ulcer in the past 12 months preceeding the survey (AOR=1.73, 95% CI: 1.05-2.86). Higher HIV knowledge was protective against HIV/syphilis infection (AOR=0.73, 95% CI: 0.54-0.99). While the overall HIV prevalence in this sample of military personnel was lower than previously reported (6.0% [95% CI: 5.12-6.97] in 2011 vs. 11.3% [95% CI: 10.01-12.68] in 2005; confidence intervals do not overlap), several factors associated with HIV/syphilis infection were identified including being separated, divorced, or widowed, having sex with a sex worker, and reporting a genital sore/ulcer in the past 12 months. HIV and syphilis education among all military personnel as they enter service and proceed forward is important to reinforce prevention methods and practices. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Screening for coronary heart disease risk factors in retail pharmacies in Sheffield, 1992.
Allison, C; Page, H; George, S
1994-01-01
OBJECTIVE--To investigate the current and likely future provision of screening services for risk factors for coronary heart disease in retail pharmacies in Sheffield. DESIGN--This was a questionnaire survey asking about screening tests currently offered, price charged per test, likely future provision of screening tests, the action respondents would take upon finding an abnormal test result, whether the pharmacy was owner-run, franchised, or part of a commercial chain, and inviting open comments from respondents. SETTING--All retail pharmacy premises on the Sheffield Family Health Services Authority list. RESULTS--Seventy seven responses were obtained to 102 questionnaires distributed. Only nine of these currently offered any screening test other than pregnancy testing, although 37 indicated that they might offer tests in the future. Thirty nine were not offering screening and had no plans to do so. Pharmacies offering or likely to offer screening tests were mainly owner-run. All pharmacists who replied to the question asking about their action upon finding abnormal result (33) reported that they would advise the patient to see a doctor. The most frequent comments made by pharmacists were about the commercial viability of screening in pharmacies and the lack of space available to ensure patient privacy and confidentiality during screening. CONCLUSIONS--Screening in retail pharmacies would probably be a commercial failure unless doctors were able to contract for screening services from pharmacies. Evidence from this study and others, however, leads us to question the desirability of this option. PMID:8189175
Hydroxychloroquine screening practice patterns within a large multispecialty ophthalmic practice.
Au, Adrian; Parikh, Vishal; Modi, Yasha S; Ehlers, Justis P; Schachat, Andrew P; Singh, Rishi P
2015-09-01
To determine provider compliance with hydroxychloroquine screening following the revised recommendations published in 2011 by the American Academy of Ophthalmology. Evaluation of adherence to a screening protocol. Subjects were identified with hydroxychloroquine as a medication by electronic query at a large multispecialty ophthalmic practice. Patients were excluded if patients: (1) were screened by an outside physician; (2) lacked recorded height, weight, start date, or dosing; or (3) took hydroxychloroquine for malaria prophylaxis. Screening tests were stratified by ophthalmic subspecialty. Guidelines define proper screening as 1 subjective test-Humphrey visual field (HVF), and 1 objective test-spectral-domain optical coherence tomography (SD OCT), fundus autofluorescence (FAF), or multifocal electroretinography (mfERG). Adherence to guidelines was determined by categorizing practices as: (1) "appropriate"-consistent with guidelines; (2) "underscreened"-insufficient testing; or (3) "inappropriate"-no testing. The study comprised 756 patients with a mean age of 56 years undergoing 1294 screening visits. Twenty-one patients received initial screenings outside the institution. Most common screening tests employed included SD OCT (56.6%), 10-2 HVF (55.0%), and Amsler grid (40.0%). Of the 735 initial screenings, 341 (46.4%) were appropriately screened, 204 (27.8%) underscreened, and 190 (25.9%) inappropriately screened. Of those who presented solely for screening (560), 307 (54.8%) were appropriately screened, 144 (25.7%) underscreened, and 109 (19.5%) inappropriately screened. Of patients presenting for hydroxychloroquine screening, 54.8% of patients received appropriate evaluation, indicating lack of adherence to guidelines. Overall, SD OCT and 10-2 HVF were the preferred screening modalities, with FAF and mfERG less frequently ordered. Copyright © 2015 Elsevier Inc. All rights reserved.
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
The relative importance of patient-reported barriers to colorectal cancer screening.
Jones, Resa M; Woolf, Steven H; Cunningham, Tina D; Johnson, Robert E; Krist, Alex H; Rothemich, Stephen F; Vernon, Sally W
2010-05-01
Colorectal cancer (CRC) screening rates are suboptimal. The most important barriers identified by patients are poorly understood. A comprehensive assessment of barriers to all recommended modalities is needed. In 2007, a questionnaire was mailed to 6100 patients, aged 50-75 years, from 12 family medicine practices in the Virginia Ambulatory Care Outcomes Research Network. People aged 65-75 years and African Americans were oversampled. Patients were asked to rate 19-21 barriers to each of four recommended tests. In 2008, responses were coded on a 5-point scale; higher scores reflected stronger barrier endorsement. The response rate was 55% (n=3357). Approximately 40% of respondents were aged >/=65 years, 30% were African-American, and 73% were adherent to screening. A clinician's failure to suggest screening and not knowing testing was necessary received the highest mean scores as barriers. Financial concerns and misconceptions were also cited. Barrier scores differed depending on whether respondents were never screened, overdue for screening, or adherent to guidelines. The top five barriers for each modality included test-specific barriers (e.g., handling stool, bowel preparation), which often outranked generic barriers to screening. Not knowing testing was necessary was a top barrier for all tests but colonoscopy. Although physician advice and awareness of the need for screening are important, barriers to screening are not homogenous across tests, and test-specific barriers warrant consideration in designing strategies to improve screening rates. Barrier scores differ by screening status, highlighting the need to address prior screening experience. Evidence that patients are more familiar with colonoscopy than with other modalities suggests an opportunity to improve screening rates by educating patients about alternative tests. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening
Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.
2009-01-01
PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838
NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid
NASA Technical Reports Server (NTRS)
Wollen, Mark; Bakke, Victor; Baker, James
2012-01-01
While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.
42 CFR 411.15 - Particular services excluded from coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... aneurysms (AAA), cardiovascular disease screening tests, diabetes screening tests, a screening... conditions and limitation specified in § 410.19 of this chapter. (13) In the case of cardiovascular disease screening tests for the early detection of cardiovascular disease or abnormalities associated with an...
Colorectal Cancer Screening: Preferences, Past Behavior, and Future Intentions.
Mansfield, Carol; Ekwueme, Donatus U; Tangka, Florence K L; Brown, Derek S; Smith, Judith Lee; Guy, Gery P; Li, Chunyu; Hauber, Brett
2018-05-09
Screening rates for colorectal cancer are below the Healthy People 2020 goal. There are several colorectal cancer screening tests that differ in terms of accuracy, recommended frequency, and administration. In this article, we compare how a set of personal characteristics correlates with preferences for colorectal cancer screening test attributes, past colorectal cancer screening behavior, and future colorectal cancer screening intentions. We conducted a discrete-choice experiment survey to assess relative preferences for attributes of colorectal cancer screening tests among adults aged 50-75 years in USA. We used a latent class logit model to identify classes of preferences and calculated willingness to pay for changes in test attributes. A set of personal characteristics were included in the latent class analysis and analyses of self-reported past screening behavior and self-assessed likelihood of future colorectal cancer screening. Latent class analysis identified three types of respondents. Class 1 valued test accuracy, class 2 valued removing polyps and avoiding discomfort, and class 3 valued cost. Having had a prior colonoscopy and a higher income were predictors of the likelihood of future screening and membership in classes 1 and 2. Health insurance and a self-reported higher risk of developing colorectal cancer were associated with prior screening and higher future screening intentions, but not class membership. We identified distinct classes of preferences focusing on different test features and personal characteristics associated with reported behavior and intentions. Healthcare providers should engage in a careful assessment of patient preferences when recommending colorectal cancer test options to encourage colorectal cancer screening uptake.
Lin, Sansan; Fischl, Anthony S; Bi, Xiahui; Parce, Wally
2003-03-01
Phospholipid molecules such as ceramide and phosphoinositides play crucial roles in signal transduction pathways. Lipid-modifying enzymes including sphingomyelinase and phosphoinositide kinases regulate the generation and degradation of these lipid-signaling molecules and are important therapeutic targets in drug discovery. We now report a sensitive and convenient method to separate these lipids using microfluidic chip-based technology. The method takes advantage of the high-separation power of the microchips that separate lipids based on micellar electrokinetic capillary chromatography (MEKC) and the high sensitivity of fluorescence detection. We further exploited the method to develop a homogenous assay to monitor activities of lipid-modifying enzymes. The assay format consists of two steps: an on-plate enzymatic reaction using fluorescently labeled substrates followed by an on-chip MEKC separation of the reaction products from the substrates. The utility of the assay format for high-throughput screening (HTS) is demonstrated using phospholipase A(2) on the Caliper 250 HTS system: throughput of 80min per 384-well plate can be achieved with unattended running time of 5.4h. This enabling technology for assaying lipid-modifying enzymes is ideal for HTS because it avoids the use of radioactive substrates and complicated separation/washing steps and detects both substrate and product simultaneously.
Kasten, Shane A; Zulli, Steven; Jones, Jonathan L; Dephillipo, Thomas; Cerasoli, Douglas M
2014-12-01
Chemical warfare nerve agents (CWNAs) are extremely toxic organophosphorus compounds that contain a chiral phosphorus center. Undirected synthesis of G-type CWNAs produces stereoisomers of tabun, sarin, soman, and cyclosarin (GA, GB, GD, and GF, respectively). Analytical-scale methods were developed using a supercritical fluid chromatography (SFC) system in tandem with a mass spectrometer for the separation, quantitation, and isolation of individual stereoisomers of GA, GB, GD, and GF. Screening various chiral stationary phases (CSPs) for the capacity to provide full baseline separation of the CWNAs revealed that a Regis WhelkO1 (SS) column was capable of separating the enantiomers of GA, GB, and GF, with elution of the P(+) enantiomer preceding elution of the corresponding P(-) enantiomer; two WhelkO1 (SS) columns had to be connected in series to achieve complete baseline resolution. The four diastereomers of GD were also resolved using two tandem WhelkO1 (SS) columns, with complete baseline separation of the two P(+) epimers. A single WhelkO1 (RR) column with inverse stereochemistry resulted in baseline separation of the GD P(-) epimers. The analytical methods described can be scaled to allow isolation of individual stereoisomers to assist in screening and development of countermeasures to organophosphorus nerve agents. © 2014 The Authors. Chirality published by John Wiley Periodicals, Inc.
An oppositely charged insect exclusion screen with gap-free multiple electric fields
NASA Astrophysics Data System (ADS)
Matsuda, Yoshinori; Kakutani, Koji; Nonomura, Teruo; Kimbara, Junji; Kusakari, Shin-ichi; Osamura, Kazumi; Toyoda, Hideyoshi
2012-12-01
An electric field screen was constructed to examine insect attraction mechanisms in multiple electric fields generated inside the screen. The screen consisted of two parallel insulated conductor wires (ICWs) charged with equal but opposite voltages and two separate grounded nets connected to each other and placed on each side of the ICW layer. Insects released inside the fields were charged either positively or negatively as a result of electricity flow from or to the insect, respectively. The force generated between the charged insects and opposite ICW charges was sufficient to capture all insects.
Validation of the Lollipop Test: A Diagnostic Screening Test of School Readiness.
ERIC Educational Resources Information Center
Chew, Alex L.; Morris, John D.
1984-01-01
The validity of the Lollipop Test: A Diagnostic Screening Test of School Readiness was examined using the Metropolitan Readiness Test (MRT), Level I, Form Q, as the criterion. Appreciable concurrent validity was found across test batteries. Implications for school readiness screening are discussed. (Author/BS)
Terakado, Shingo; Glass, Thomas R; Sasaki, Kazuhiro; Ohmura, Naoya
2014-01-01
A simple new model for estimating the screening performance (false positive and false negative rates) of a given test for a specific sample population is presented. The model is shown to give good results on a test population, and is used to estimate the performance on a sampled population. Using the model developed in conjunction with regulatory requirements and the relative costs of the confirmatory and screening tests allows evaluation of the screening test's utility in terms of cost savings. Testers can use the methods developed to estimate the utility of a screening program using available screening tests with their own sample populations.
De Ryck, R; Struelens, M J; Serruys, E
1994-01-01
Four screens for the rapid (4 to 6 h) biochemical detection of pathogens from enteric isolation media are described. The Salmonella screen consisted of Kligler iron agar (KIA), motility-indole-urea-tryptophan-deamination semisolid medium (MIU-TDA), and the o-nitrophenyl-beta-D-galactopyranoside (ONPG) test; the Shigella screen consisted of KIA, MIU-TDA, the ONPG test, and the lysine decarboxylation-indole test; the Yersinia screen consisted of a rhamnose broth; the Aeromonas screen consisted of a xylose agar plate. When tested on 2,102 fresh isolates and 71 stock strains, the screens correctly detected 212 enteric pathogens (sensitivity, 100%), with a specificity of 98.1%. PMID:8077408
Cancer Screening Overview (PDQ®)—Patient Version
Cancer screening means looking for cancer before symptoms appear, when cancer may be easier to treat. Screening tests can help reduce the risk of dying from some cancers, but all tests have potential risks, too. Learn more about cancer screening and available tests in this expert-reviewed summary.
NASA Astrophysics Data System (ADS)
Souli, M.; Dolégiéviez, P.; Fadil, M.; Gallardo, P.; Levallois, R.; Munoz, H.; Ozille, M.; Rouillé, G.; Galet, F.
2011-12-01
A cryogenic trap system called Cryotrap has been studied and developed in the framework of nuclear safety studies for SPIRAL2 accelerator. The main objective of Cryotrap is to confine and reduce strongly the migration of radioactive volatile isotopes in beam lines. These radioactive gases are produced after interaction between a deuteron beam and a fissile target. Mainly, Cryotrap is composed by a vacuum vessel and two copper thermal screens maintained separately at two temperatures T1=80 K and T2=20 K. A Cryocooler with two stages at previous temperatures is used to remove static heat losses of the cryostat and ensure an efficient cooling of the system. Due to strong radiological constraints that surround Cryotrap, the coupling system between Cryocooler and thermal screens is based on aluminum thermo-mechanical contraction. The main objective of this original design is to limit direct human maintenance interventions and provide maximum automated operations. A preliminary prototype of Cryotrap has been developed and tested at GANIL laboratory to validate its design, and determine its thermal performance and trapping efficiency. In this paper, we will first introduce briefly SPIRAL2 project and discuss the main role of Cryotrap in nuclear safety of the accelerator. Then, we will describe the proposed conceptual design of Cryotrap and its main characteristics. After that, we will focus on test experiment and analyze experimental data. Finally, we will present preliminary results of gas trapping efficiency tests.
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis.
Welton, Nicky J; McAleenan, Alexandra; Thom, Howard Hz; Davies, Philippa; Hollingworth, Will; Higgins, Julian Pt; Okoli, George; Sterne, Jonathan Ac; Feder, Gene; Eaton, Diane; Hingorani, Aroon; Fawsitt, Christopher; Lobban, Trudie; Bryden, Peter; Richards, Alison; Sofat, Reecha
2017-05-01
Atrial fibrillation (AF) is a common cardiac arrhythmia that increases the risk of thromboembolic events. Anticoagulation therapy to prevent AF-related stroke has been shown to be cost-effective. A national screening programme for AF may prevent AF-related events, but would involve a substantial investment of NHS resources. To conduct a systematic review of the diagnostic test accuracy (DTA) of screening tests for AF, update a systematic review of comparative studies evaluating screening strategies for AF, develop an economic model to compare the cost-effectiveness of different screening strategies and review observational studies of AF screening to provide inputs to the model. Systematic review, meta-analysis and cost-effectiveness analysis. Primary care. Adults. Screening strategies, defined by screening test, age at initial and final screens, screening interval and format of screening {systematic opportunistic screening [individuals offered screening if they consult with their general practitioner (GP)] or systematic population screening (when all eligible individuals are invited to screening)}. Sensitivity, specificity and diagnostic odds ratios; the odds ratio of detecting new AF cases compared with no screening; and the mean incremental net benefit compared with no screening. Two reviewers screened the search results, extracted data and assessed the risk of bias. A DTA meta-analysis was perfomed, and a decision tree and Markov model was used to evaluate the cost-effectiveness of the screening strategies. Diagnostic test accuracy depended on the screening test and how it was interpreted. In general, the screening tests identified in our review had high sensitivity (> 0.9). Systematic population and systematic opportunistic screening strategies were found to be similarly effective, with an estimated 170 individuals needed to be screened to detect one additional AF case compared with no screening. Systematic opportunistic screening was more likely to be cost-effective than systematic population screening, as long as the uptake of opportunistic screening observed in randomised controlled trials translates to practice. Modified blood pressure monitors, photoplethysmography or nurse pulse palpation were more likely to be cost-effective than other screening tests. A screening strategy with an initial screening age of 65 years and repeated screens every 5 years until age 80 years was likely to be cost-effective, provided that compliance with treatment does not decline with increasing age. A national screening programme for AF is likely to represent a cost-effective use of resources. Systematic opportunistic screening is more likely to be cost-effective than systematic population screening. Nurse pulse palpation or modified blood pressure monitors would be appropriate screening tests, with confirmation by diagnostic 12-lead electrocardiography interpreted by a trained GP, with referral to a specialist in the case of an unclear diagnosis. Implementation strategies to operationalise uptake of systematic opportunistic screening in primary care should accompany any screening recommendations. Many inputs for the economic model relied on a single trial [the Screening for Atrial Fibrillation in the Elderly (SAFE) study] and DTA results were based on a few studies at high risk of bias/of low applicability. Comparative studies measuring long-term outcomes of screening strategies and DTA studies for new, emerging technologies and to replicate the results for photoplethysmography and GP interpretation of 12-lead electrocardiography in a screening population. This study is registered as PROSPERO CRD42014013739. The National Institute for Health Research Health Technology Assessment programme.
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2012 CFR
2012-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2014 CFR
2014-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2013 CFR
2013-04-01
... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
Color View 'Dodo' and 'Baby Bear' Trenches
NASA Technical Reports Server (NTRS)
2008-01-01
NASA's Phoenix Mars Lander's Surface Stereo Imager took this image on Sol 14 (June 8, 2008), the 14th Martian day after landing. It shows two trenches dug by Phoenix's Robotic Arm. Soil from the right trench, informally called 'Baby Bear,' was delivered to Phoenix's Thermal and Evolved-Gas Analyzer, or TEGA, on Sol 12 (June 6). The following several sols included repeated attempts to shake the screen over TEGA's oven number 4 to get fine soil particles through the screen and into the oven for analysis. The trench on the left is informally called 'Dodo' and was dug as a test. Each of the trenches is about 9 centimeters (3 inches) wide. This view is presented in approximately true color by combining separate exposures taken through different filters of the Surface Stereo Imager. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.Lui, Kung-Jong; Chang, Kuang-Chao
2015-01-01
In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... recovery. There is no standard or routine screening test for endometrial cancer. Screening for endometrial cancer is under study and there are screening clinical trials taking place ...
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... stage . There is no standard or routine screening test for esophageal cancer. Screening for esophageal cancer is under study with screening clinical trials taking place in many ...
Cost-effectiveness of rapid syphilis screening in prenatal HIV testing programs in Haiti.
Schackman, Bruce R; Neukermans, Christopher P; Fontain, Sandy N Nerette; Nolte, Claudine; Joseph, Patrice; Pape, Jean W; Fitzgerald, Daniel W
2007-05-01
New rapid syphilis tests permit simple and immediate diagnosis and treatment at a single clinic visit. We compared the cost-effectiveness, projected health outcomes, and annual cost of screening pregnant women using a rapid syphilis test as part of scaled-up prenatal testing to prevent mother-to-child HIV transmission in Haiti. A decision analytic model simulated health outcomes and costs separately for pregnant women in rural and urban areas. We compared syphilis syndromic surveillance (rural standard of care), rapid plasma reagin test with results and treatment at 1-wk follow-up (urban standard of care), and a new rapid test with immediate results and treatment. Test performance data were from a World Health Organization-Special Programme for Research and Training in Tropical Diseases field trial conducted at the GHESKIO Center Groupe Haitien d'Etude du Sarcome de Kaposi et des Infections Opportunistes in Port-au-Prince. Health outcomes were projected using historical data on prenatal syphilis treatment efficacy and included disability-adjusted life years (DALYs) of newborns, congenital syphilis cases, neonatal deaths, and stillbirths. Cost-effectiveness ratios are in US dollars/DALY from a societal perspective; annual costs are in US dollars from a payer perspective. Rapid testing with immediate treatment has a cost-effectiveness ratio of $6.83/DALY in rural settings and $9.95/DALY in urban settings. Results are sensitive to regional syphilis prevalence, rapid test sensitivity, and the return rate for follow-up visits. Integrating rapid syphilis testing into a scaled-up national HIV testing and prenatal care program would prevent 1,125 congenital syphilis cases and 1,223 stillbirths or neonatal deaths annually at a cost of $525,000. In Haiti, integrating a new rapid syphilis test into prenatal care and HIV testing would prevent congenital syphilis cases and stillbirths, and is cost-effective. A similar approach may be beneficial in other resource-poor countries that are scaling up prenatal HIV testing.
Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J
2017-07-01
This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years.
Screening for diabetes and prediabetes should be cost-saving in patients at high risk.
Chatterjee, Ranee; Narayan, K M Venkat; Lipscomb, Joseph; Jackson, Sandra L; Long, Qi; Zhu, Ming; Phillips, Lawrence S
2013-07-01
Although screening for diabetes and prediabetes is recommended, it is not clear how best or whom to screen. We therefore compared the economics of screening according to baseline risk. Five screening tests were performed in 1,573 adults without known diabetes--random plasma/capillary glucose, plasma/capillary glucose 1 h after 50-g oral glucose (any time, without previous fast, plasma glucose 1 h after a 50-g oral glucose challenge [GCTpl]/capillary glucose 1 h after a 50-g oral glucose challenge [GCTcap]), and A1C--and a definitive 75-g oral glucose tolerance test. Costs of screening included the following: costs of testing (screen plus oral glucose tolerance test, if screen is positive); costs for false-negative results; and costs of treatment of true-positive results with metformin, all over the course of 3 years. We compared costs for no screening, screening everyone for diabetes or high-risk prediabetes, and screening those with risk factors based on age, BMI, blood pressure, waist circumference, lipids, or family history of diabetes. Compared with no screening, cost-savings would be obtained largely from screening those at higher risk, including those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, with differences of up to -46% of health system costs for screening for diabetes and -21% for screening for dysglycemia110, respectively (all P < 0.01). GCTpl would be the least expensive screening test for most high-risk groups for this population over the course of 3 years. From a health economics perspective, screening for diabetes and high-risk prediabetes should target patients at higher risk, particularly those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, for whom screening can be most cost-saving. GCTpl is generally the least expensive test in high-risk groups and should be considered for routine use as an opportunistic screen in these groups.
Magnetohydrodynamic pump with a system for promoting flow of fluid in one direction
Lemoff, Asuncion V [Union City, CA; Lee, Abraham P [Irvine, CA
2010-07-13
A magnetohydrodynamic pump for pumping a fluid. The pump includes a microfluidic channel for channeling the fluid, a MHD electrode/magnet system operatively connected to the microfluidic channel, and a system for promoting flow of the fluid in one direction in the microfluidic channel. The pump has uses in the medical and biotechnology industries for blood-cell-separation equipment, biochemical assays, chemical synthesis, genetic analysis, drug screening, an array of antigen-antibody reactions, combinatorial chemistry, drug testing, medical and biological diagnostics, and combinatorial chemistry. The pump also has uses in electrochromatography, surface micromachining, laser ablation, inkjet printers, and mechanical micromilling.
Advances in membrane technology for the NASA redox energy storage system
NASA Technical Reports Server (NTRS)
Ling, J. S.; Charleston, J.
1980-01-01
Anion exchange membranes used in the system serve as a charge transferring medium as well as a reactant separator and are the key enabling component in this storage technology. Each membrane formulation undergoes a series of screening tests for area-resistivity, static (non-flow) diffusion rate determination, and performance in Redox systems. The CDIL series of membranes has, by virtue of its chemical stability and high ion exchange capacity, demonstrated superior properties in the redox environment. Additional resistivity results at several acid and iron solution concentrations, iron diffusion rates, and time dependent iron fouling of the various membrane formulations are presented in comparison to past standard formulations.
[Screening of antifungi endophytic actinomyces strains from salvia przewalskii in Tibean Plateau].
Liu, Song-Qing; Jiang, Hua-Ming; Guan, Tong-Wei; Qi, Shan-Shan; Gu, Yun-Fu; Zhao, Ke; Wang, Xu; Zhang, Xiao-Ping
2013-10-01
Twenty-four endophytic actinomycetes strains were isolated from the Salvia przewalskii in Tibetan Plateau of China by tablet coating method. Fusarium moniliforme, Helminthosporium turcicum and Bipolaris maydis were selected as indicator fungi to test the antimicrobial activities of these endophytic actinomycetes by tablet confrontation method. The results showed that 21 strains can produce antimicrobial substances which accounts for 85.7% of the total separates number. Four strains of endogenous actinomyces have more obvious antifungi activity. According to results of morphology and culture properties and 16S rDNA sequences of endophytic actinomyces, it is concluded that all of the isolates were streptomycetes trains.
Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.
2010-01-01
Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553
A study on the recycling of scrap integrated circuits by leaching.
Lee, Ching-Hwa; Tang, Li-Wen; Popuri, Srinivasa R
2011-07-01
In order to minimize the problem of pollution and to conserve limited natural resources, a method to recover the valuable metals such as gold, silver and copper) present in the scrap integrated circuits (ICs) was developed in the present study. Roasting, grinding, screening, magnetic separation, melting and leaching were adopted to investigate the efficiency of recovery of gold, silver and copper from scrap ICs. The collected scrap IC samples were roasted at 850 °C to destroy their plastic resin sealing material, followed by screening and magnetic separation to separate the metals from the resin residue. The non-ferrous materials (0.840 mm) were mainly composed of copper and could be melted into a copper alloy. Non-ferrous materials containing gold (860.05 ppm), silver (1323.12 ppm) and copper (37259.7 ppm) (size less than 50 mesh) were recovered 100% by a leaching process and thiourea was used as a leaching reagent.
Hepatitis C virus testing in adults living with HIV: a need for improved screening efforts.
Yehia, Baligh R; Herati, Ramin S; Fleishman, John A; Gallant, Joel E; Agwu, Allison L; Berry, Stephen A; Korthuis, P Todd; Moore, Richard D; Metlay, Joshua P; Gebo, Kelly A
2014-01-01
Guidelines recommend hepatitis C virus (HCV) screening for all people living with HIV (PLWH). Understanding HCV testing practices may improve compliance with guidelines and can help identify areas for future intervention. We evaluated HCV screening and unnecessary repeat HCV testing in 8,590 PLWH initiating care at 12 U.S. HIV clinics between 2006 and 2010, with follow-up through 2011. Multivariable logistic regression examined the association between patient factors and the outcomes: HCV screening (≥1 HCV antibody tests during the study period) and unnecessary repeat HCV testing (≥1 HCV antibody tests in patients with a prior positive test result). Overall, 82% of patients were screened for HCV, 18% of those screened were HCV antibody-positive, and 40% of HCV antibody-positive patients had unnecessary repeat HCV testing. The likelihood of being screened for HCV increased as the number of outpatient visits rose (adjusted odds ratio 1.02, 95% confidence interval 1.01-1.03). Compared to men who have sex with men (MSM), patients with injection drug use (IDU) were less likely to be screened for HCV (0.63, 0.52-0.78); while individuals with Medicaid were more likely to be screened than those with private insurance (1.30, 1.04-1.62). Patients with heterosexual (1.78, 1.20-2.65) and IDU (1.58, 1.06-2.34) risk compared to MSM, and those with higher numbers of outpatient (1.03, 1.01-1.04) and inpatient (1.09, 1.01-1.19) visits were at greatest risk of unnecessary HCV testing. Additional efforts to improve compliance with HCV testing guidelines are needed. Leveraging health information technology may increase HCV screening and reduce unnecessary testing.
Tershakovec, A M; Brannon, S D; Bennett, M J; Shannon, B M
1995-08-01
To measure the additional costs of office-based laboratory testing due to the implementation of the Clinical Laboratory Improvement Amendments of 1988 (CLIA '88), using cholesterol screening for children as an example. Four- to ten-year-old children who received their well child care at one of seven participating pediatric practices were screened for hypercholesterolemia. The average number of analyses per day and days per month were derived from the volume of testing completed by the practices. Nurses and technicians time in the screening process were measured and personnel costs were calculated based on salary and fringe benefit rates. Costs of supplies, analyzing control samples, instrument calibration, and instrument depreciation were included. Costs estimates of screening were then completed. CLIA '88 implementation costs were derived from appropriate proficiency testing and laboratory inspection programs. In six practices completing a low volume of testing, 2807 children (5 to 6 children per week) were screened during the observation period, while 414 (about 25 children per week) were screened in one high-volume practice implementing universal screening over a 4-month period. For the six low-volume practices, the cost of screening was $10.60 per child. This decreased to $5.47 for the high-volume practice. Estimated costs of CLIA '88 implementation, including additional proficiency testing and laboratory inspection, added $3.20 per test for the low-volume practices, and $0.71 per test for the high-volume testing. Implementation of CLIA adds significantly to the cost of office-based chemistry laboratory screening. Despite these additional expenses, the cost of testing is still within a reasonable charge for laboratory testing, and is highly sensitive to the volume of tests completed.
The clinical value of HPV E6/E7 and STAT3 mRNA detection in cervical cancer screening.
Fan, Yibing; Shen, Zongji
2018-05-01
To explore the value of human papillomavirus (HPV) E6/E7 and signal transducer and activator of transcription 3 (STAT3) mRNA detection in the screening of cervical lesions. 192 patients with abnormal ThinPrep cytology test (TCT) results and/or high-risk HPV infection were screened to identify possible cervical lesions in cases. Diagnoses were confirmed by histopathology. Fluorescence in situ hybridization (FISH) was performed to detect and qualify the mRNAs of HPV E6/E7, STAT3, and Survivin in cervical exfoliated cells. In addition, the performance of separate and combined mRNA detection methods were compared with TCT, HR-HPV DNA schemes respectively. 1. Compared with HPVE6/E7 and STAT3 mRNA methods, Survivin mRNA assay had poor specificity (Sp), Youden index (YI) and concordance rate. 2. HPV E6/E7, STAT3, and STAT3 + HR-HPV methods had the best Sp, concordance rate and positive predictive value (PPV) for cervical lesions screening and atypical squamous cells of undetermined significance (ASCUS) triage. For screening of high grade squamous intraepithelial lesions or greater (HSILs+), no difference was observed in the Se of mRNA detection methods in comparison with that of TCT, HR-HPV and TCT + HR-HPV, whereas the false positive rate (FPR) decreased by 41.48%/55.99%/17.19% and the colposcopy referral rate reduced by about 20.00%/25.00%/11.17%. For triage of women with ASCUS, no difference was observed in the Se of mRNA detection methods as compared to that of HR-HPV (χ 2 = 1.05, P > 0.75), while the FPR decreased by 45.83%/37.50%/41.66% and the colposcopy referral rate reduced by 32.42%/22.60%/25.28%, respectively. The Se, YI, and PPV of the combined methods increased in comparison to each method alone. 3. Compared with the TCT + HR-HPV method, HPV E6/E7 + STAT3 method had perfect Sp (95.92%) and PPV (95.40%) for screening HSILs+, the FPR and colposcopy referral rate decreased by 31.06% and 22.48% respectively. 1. The expression of HPV E6/E7 and STAT3 mRNA confirmed using FISH assay is expected to be a new method and molecular marker for cervical lesions screening. Survivin mRNA was excluded due to its poor performance. 2. HPV E6/E7, STAT3, and STAT3 +HR-HPV assays could be new approaches for cervical cancer screening and ASCUS triage, and the efficiency of combined screening program was better than that of a separate one. 3. HPV E6/E7 + STAT3 regimen is expected to be a diagnostic strategy for cervical lesions. Copyright © 2018 Elsevier GmbH. All rights reserved.
Achromatized transmission-type holographic screen for a multiview stereoscopic image system
NASA Astrophysics Data System (ADS)
Hwang, Seon-Ho; Bobrinev, V. I.; Son, Jung-Young; Shestak, S. A.; Jeon, Hyung-Wook
1997-09-01
The main drawback of the use of transmission-type holographic screens is poor color reproduction caused by their high spectral dispersion. For overcoming this drawback, a long, narrow diffusing slit is used as an object when recording the screen. The necessary size and position of the slit relative to the photoplate and to the recording and reconstruction beams are determined by the phase relations of the beams. By use of the slit, holographic screens of 30 cm 40 cm are recorded with a diverging reference beam and are used to display a multiview full-color stereoscopic image. The images displayed on the screen show no sign of color separation except near the edges of the screen. The image brightness on the screen is high enough that it can be watched in a normally illuminated room.
NASA Astrophysics Data System (ADS)
Taruvai Kalyana Kumar, Rajeshwari; de Mello Gindri, Izabelle; Kinnamon, David; Kanchustambham, Pradyotha; Rodrigues, Danieli; Prasad, Shalini; BiomaterialsOsseointegration; Novel Engineering Lab Collaboration
2015-03-01
Characterization and analysis of rare cells provide critical cues for early diagnosis of diseases. Electrokinetic cell separation has been previously established to have greater efficiency when compared to traditional flow cytometry methods. It has been shown by many researchers that buffer solutions in which cells are suspended in, have enormous effects on producing required dielectrophoretic (DEP) forces to characterize cells. Most commonly used suspension buffers used are deionized water and cell media. However, these solutions exhibit high level of intrinsic noise, which greatly masks the electrokinetic signals from cells under study. Ionic liquids (ILs) show promise towards the creation of conductive fluids with required electrical properties. The goal of this project is to design and test ILs for enhancing DEP forces on cells while creating an environment for preserving their integrity. We analyzed two methylimidazolium based ILs as suspension medium for cell separation. These dicationic ILs possess slight electrical and structural differences with high thermal stability. The two ILs were tested for cytotoxicity using HeLa and bone cells. The effects of electrical neutrality, free charge screening due to ILs towards enhanced electrokinetic signals from cells were studied with improved system resolution and no harmful effects.
Nicolaides, K H; Syngelaki, A; Poon, L C; Gil, M M; Wright, D
2014-01-01
To examine potential performance of screening for trisomies by cell-free (cf) DNA testing in maternal blood contingent on results of first-line testing by combinations of fetal translucency thickness (NT), fetal heart rate (FHR), ductus venosus pulsatility index (DV PIV), and serum-free β-human chorionic gonadotropin (β-hCG), pregnancy-associated plasma protein-A (PAPP-A), placental growth factor (PLGF) and α-fetoprotein (AFP). Performance was estimated for firstly, screening by cfDNA in all pregnancies and secondly, cfDNA testing contingent on results of first-line testing by combinations of ultrasound and biochemical markers. In first-line screening by cfDNA testing, the detection rate for trisomy 21 and trisomies 18 or 13 would be 99 and 96%, respectively, after invasive testing in 1% of the population. In contingent screening, a detection rate of 98% for trisomy 21 and 96% for trisomy 18 or 13, at an invasive testing rate of 0.7%, can be achieved by carrying out cfDNA testing in about 35, 20 and 11% of cases identified by first-line screening with the combined test alone (age, NT, FHR, β-hCG, PAPP-A), the combined test plus PLGF and AFP and the combined test plus PLGF, AFP and DV PIV, respectively. Effective first-trimester screening for trisomies can be achieved by contingent screening incorporating biomarkers and cfDNA testing. © 2013 S. Karger AG, Basel.
Jacobson, Gary P; McCaslin, Devin L; Piker, Erin G; Gruenwald, Jill; Grantham, Sarah; Tegel, Lauren
2011-01-01
The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States. A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine. Patients with complete electro- or videonystagmography testing, cervical vestibular evoked myogenic potential (cVEMP) testing, and the RTSBFCSS screening test were included in the analysis. A series of 2 × 2 tables were created that represented the number of "true positives," "true negatives," "false positives," and "false negatives" of the RTSBFCSS under conditions where the caloric test was abnormal and then separately where the cVEMP test was abnormal. The data were analyzed in a manner such that sensitivity, specificity, and both positive and negative predictive value of the RTSBFCSS could be calculated. When the caloric test was used as the criterion standard and the subject selection criteria in the NHANES study were used (i.e., subjects who were able to maintain postural stability for trials 1-3 of the RTSBFCSS; N = 45), the sensitivity and specificity of the RTSBFCSS to impairment of the horizontal semicircular canal or superior vestibular nerve were 55% and 64%, respectively, yielding positive and negative predictive values of 55% and 64%, respectively. When all patients aged 40 yr or older were evaluated (N = 103), the sensitivity and specificity were 61% and 58%, respectively, yielding positive and negative predictive values of 39% and 78%, respectively. Using the cVEMP test as the criterion standard for the detection of impairment affecting the saccule and/or inferior vestibular nerve did not improve the performance criteria of the NHANES screening measure. The RTSBFCSS should not be used as a screening measure for vestibular impairment.
Labani, Satyanarayana; Asthana, Smita
2016-01-01
Human papillomavirus (HPV) is recommended as a primary screening tool for cervical screening. Assessment of age-specific performance of newer HPV careHPV DNA testing is important as risk of cervical intraepithelial neoplasia (CIN) varies at different ages. We aim to evaluate careHPV in comparison to Papanicolaou (Pap) test and visual inspection of the cervix with acetic acid (VIA) cervical screening tests for the detection of high-grade CIN. The cross sectional study was conducted in a rural population of North India. Ever-married women 30-59 years of age were invited for screening by careHPV (self-collected vaginal and physician-collected cervical samples), Pap test and VIA. Associations for trend in age for detecting histological-confirmed CINII+ and CINIII+ for each screening test were evaluated. Age-specific association with each screening test was evaluated. Of a total of 7761 women invited, 5032 were screened and analysis was performed on 4658 with all screen test results. No significant (p>0.05) association of age for any screening test in the detection of CINII+ or CINIII+ was observed. For the older age group, cervical HPV (CHPV) showed high sensitivity and specificity for CINII+ detection. Specificity of CHPV or vaginal HPV (VHPV) was equal or higher than Pap in all age groups. Cervical screening options of CHPV or VHPV, or Pap, performed equally in the younger age group while CHPV might be an option for all ages in the detection of high-grade CIN. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Risks of Esophageal Cancer Screening
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... stage . There is no standard or routine screening test for esophageal cancer. Screening for esophageal cancer is under study with screening clinical trials taking place in many ...
Risks of Endometrial Cancer Screening
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... recovery. There is no standard or routine screening test for endometrial cancer. Screening for endometrial cancer is under study and there are screening clinical trials taking place ...
Li, Liang; Mustafi, Debarshi; Fu, Qiang; Tereshko, Valentina; Chen, Delai L.; Tice, Joshua D.; Ismagilov, Rustem F.
2006-01-01
High-throughput screening and optimization experiments are critical to a number of fields, including chemistry and structural and molecular biology. The separation of these two steps may introduce false negatives and a time delay between initial screening and subsequent optimization. Although a hybrid method combining both steps may address these problems, miniaturization is required to minimize sample consumption. This article reports a “hybrid” droplet-based microfluidic approach that combines the steps of screening and optimization into one simple experiment and uses nanoliter-sized plugs to minimize sample consumption. Many distinct reagents were sequentially introduced as ≈140-nl plugs into a microfluidic device and combined with a substrate and a diluting buffer. Tests were conducted in ≈10-nl plugs containing different concentrations of a reagent. Methods were developed to form plugs of controlled concentrations, index concentrations, and incubate thousands of plugs inexpensively and without evaporation. To validate the hybrid method and demonstrate its applicability to challenging problems, crystallization of model membrane proteins and handling of solutions of detergents and viscous precipitants were demonstrated. By using 10 μl of protein solution, ≈1,300 crystallization trials were set up within 20 min by one researcher. This method was compatible with growth, manipulation, and extraction of high-quality crystals of membrane proteins, demonstrated by obtaining high-resolution diffraction images and solving a crystal structure. This robust method requires inexpensive equipment and supplies, should be especially suitable for use in individual laboratories, and could find applications in a number of areas that require chemical, biochemical, and biological screening and optimization. PMID:17159147
Mathews, Miya Gugulethu; Ajayi, Oyemitan Idris; Opeoluwa, Oyedeji Oyehan; Oluwatobi, Oluwafemi Samuel; Benedicta N, Nkeh-Chungag; Phindile, Songca Sandile; Oyedeji; Omowumi, Adebola
2016-01-01
Pentanisia prunelloides is a medicinal plant widely used to remedy various ailments including infections, fever and rheumatism in Eastern Cape Province of South Africa. There is scanty report on the phytochemical and biological properties of the plant; hence various solvent extracts of the dried plant materials were phytochemically screened, and its aqueous extract evaluated for acute toxicity effect, analgesic and antiinflammatory properties in rodents. Different extracts of both leaf and rhizome were obtained separately with ethanol, methanol and water. Portions of the filtrate were used for qualitative screening of secondary metabolites and remaining portions were concentrated and dried. Dried grounded leaf and rhizome of the plant were also used for quantitative screening for some major components. The aqueous extract of the leaf and rhizome were used for acute toxicity (LD 50 ) test, antiinflammatory and analgesic activities in rodents. The qualitative phytochemical screening showed the presence of several phytoconstituents with saponins, flavonoids and alkaloids constituting highest constituents in the leaf and rhizome. The LD50: of the aqueous extracts (from leaf or rhizome) was found to be ≥5000 mg/kg orally. The leaf and rhizome aqueous extract (250-500 mg/kg) significantly (p<0.01) reduced egg albumin-induced paw oedema and paw licking in mice induced by formalin, signifying antinociceptive and antiinflammatory activities respectively. It is concluded that the leaf and rhizome of P. prunelloides are rich in various phytochemicals which could be associated with their medicinal uses. The aqueous leaf and rhizome extracts are similarly non-toxic orally, showed antiinflammatory and analgesic potentials thus rationalizing its use in folkloric medicine.
Using the Bergman-Paris Question to screen seniors in the emergency department.
Lague, Antoine; Voyer, Philippe; Ouellet, Marie-Christine; Boucher, Vale Rie; Giroux, Marianne; Pelletier, Mathieu; Gouin, E Milie; Daoust, Raoul; Berthelot, Simon; Morin, Miche le; Minh Vu, Thien Tuong; Lee, Jacques; Brousseau, Audrey-Anne; Sirois, Marie-Jose E; E Mond, Marcel
2017-10-16
In the fast pace of the Emergency Department (ED), clinicians are in need of tailored screening tools to detect seniors who are at risk of adverse outcomes. We aimed to explore the usefulness of the Bergman-Paris Question (BPQ) to expose potential undetected geriatric syndromes in community-living seniors presenting to the ED. This is a planned sub-study of the INDEED multicentre prospective cohort study, including independent or semi-independent seniors (≥65 years old) admitted to hospital after an ED stay ≥8 hours and who were not delirious. Patients were assessed using validated screening tests for 3 geriatric syndromes: cognitive and functional impairment, and frailty. The BPQ was asked upon availability of a relative at enrolment. BPQ's sensitivity and specificity analyses were used to ascertain outcomes. A response to the BPQ was available for 171 patients (47% of the main study's cohort). Of this number, 75.4% were positive (suggesting impairment), and 24.6% were negative. To detect one of the three geriatric syndromes, the BPQ had a sensitivity of 85.4% (95% CI [76.3, 92.0]) and a specificity of 35.4% (95% CI [25.1, 46.7]). Similar results were obtained for each separate outcome. Odds ratio demonstrated a higher risk of presence of geriatric syndromes. The Bergman-Paris Question could be an ED screening tool for possible geriatric syndrome. A positive BPQ should prompt the need of further investigations and a negative BPQ possibly warrants no further action. More research is needed to validate the usefulness of the BPQ for day-to-day geriatric screening by ED professionals or geriatricians.
Vuillermoz, Cécile; Vandentorren, Stéphanie; Roze, Mathilde; Rondet, Claire; Chauvin, Pierre
2017-05-01
Little is known about the prevalence of cervical cancer screening (CCS) and its correlates among homeless women in France. The objectives of this study were to determine the prevalence of women who had never been screened for cervical cancer and to identify the associated factors. This cross-sectional study was based on data collected in the ENFAMS survey, which was conducted in 2013 among 764 sheltered homeless mothers in the Greater Paris Area. Robust Poisson regression models were used to estimate the association between no lifetime CCS and certain sociodemographic and health-related factors (selected from the behavioral model of vulnerable populations). Analyses were carried out separately for women with and without a regular gynaecological follow-up (RGF). The proportion of never-screeners was 33% among the women with an RGF versus 64% among those without an RGF (P<0.001). Among the latter, never having been screened for CCS was associated mainly with socioeconomic conditions, the length of time lived in France, a history of delivery in France and the duration of homelessness. In those with an RGF, the factors were mainly poor health service utilization and language difficulties. This first quantitative study of CCS among homeless women in the Greater Paris Area points to the need for it to be proposed and performed more systematically in primary care. Every contact between this hard-to-reach population and health services should be an opportunity to check their screening status and to ensure that those in need actually undergo a Pap test.
Screening with Papanicolaou tests in Alberta
Symonds, Christopher J.; Chen, Wenxin; Rose, Marianne Sarah; Cooke, Lara J.
2018-01-01
Abstract Objective To describe the prevalence and geographic distribution of cervical cancer screening, as well as the age groups of those undergoing screening, in Alberta, and to determine if screening practices conform to current guidelines and follow Choosing Wisely Canada recommendations. Design Descriptive study using data from the Alberta Ministry of Health Analytics and Performance Reporting Branch. Setting Alberta. Participants Women who had 1 or more Papanicolaou tests between 2011 and 2013. Main outcome measures Number of women aged 15 to 20 and those aged 70 and older who had 1 or more Pap tests in a 3-year period; year-to-year trends in screening rates for women in these 2 age groups; trends in screening rates in various geographic regions (ie, cities and zones) in Alberta; and the discipline of clinicians who ordered the Pap tests. Results Between 2011 and 2013, 805 632 women in the province of Alberta had 1 or more Pap tests for cervical cancer screening. Overall, 25 511 (17.5%) women aged 15 to 20 and 16 818 (10.3%) aged 70 and older were screened contrary to most existing guidelines. Screening rates varied markedly in different geographic regions of the province. Most Pap tests were ordered by family physicians or general practitioners. Conclusion Within the geographic regions of Alberta, provincial, national, and international guidelines for screening with Pap tests are inconsistently followed. This strongly echoes the need for clinicians and patients to consider the Choosing Wisely Canada recommendations and current guidelines for cervical cancer screening. PMID:29358254
Seshul, Merritt; Pillsbury, Harold; Eby, Thomas
2006-09-01
The objective was to determine the agreement of the positive results from a multiple skin prick test (SPT) device with the ability to determine a definable endpoint through intradermal dilutional testing (IDT) to compare semiquantitatively the degree of positivity of SPT results with quantitative results from IDT and to analyze the cost of immunotherapy based on SPT compared with IDT guided by SPT. Retrospective review of clinical data (random accrual). One hundred thirty-four patients underwent allergy screening using a multiple SPT device. Antigens testing positive by skin prick device were tested using IDT on a separate day. Antigens testing negative by SPT were not evaluated by IDT. Regional allergy testing practice patterns were determined, and a cost analysis using Medicare rates was performed There was good agreement between an antigen testing positive by SPT and the determination of a definable endpoint (93.33%, n = 1,334 antigens). The degree of positivity from the SPT correlated poorly with the final endpoint concentration (r = 0.40, P < .0001). Blended testing techniques were similar in cost when compared with several commonly used allergy testing protocols. Antigens which show reactivity to a multiple SPT device usually have a treatable endpoint that is independent of the degree of positivity of the SPT result. IDT is an important step in the determination of the strongest starting dose of immunotherapy that may be safely administered. Initiating immunotherapy in this manner may potentially create significant health care savings by shortening the time required for a patient to reach their individual maximally tolerated dose. The use of a relatively large screening panel is cost effective and does not increase the average number of antigens treated by immunotherapy. Blended allergy testing techniques that include IDT in their protocol are comparable in cost with commonly used allergy testing protocols.
Piette, Christine; Durand, Gérard; Bretagne, Jean-François; Faivre, Jean
2017-03-01
Compliance with colorectal cancer screening is critical to its effectiveness. The organisation of the mass screening programme in France has recently been modified with no evaluation of the consequences. To evaluate the impact of the way the screening test is delivered on compliance. During the first six months of the screening campaign (Ille-Vilaine, Brittany), general practitioners were asked to propose a faecal immunochemical test (FIT), OC-Sensor, to individuals at average risk for colorectal cancer (n=152,097). A subset of non-participants in the medical phase (n=13,071) was randomly chosen to receive a reminder that included the screening test or a simple postal reminder without the screening test. Compliance was 31% if the screening test was proposed during a medical consultation. In non-participants during the medical phase, it was 45% in those receiving both a reminder and the screening test and 28% amongst those receiving a simple reminder. An estimated overall participation rate of 54% can be expected if non-participants in the medical phase are sent a reminder together with the screening test. In France, a compliance rate above the minimum uptake rate of 45% recommended by European Union experts can be achieved if the FIT is mailed to non-participants after the medical free-offer phase. Copyright © 2016. Published by Elsevier Ltd.
ERIC Educational Resources Information Center
May, Diane E.; Hallin, Mary J.; Kratochvil, Christopher J.; Puumala, Susan E.; Smith, Lynette S.; Reinecke, Mark A.; Silva, Susan G.; Weller, Elizabeth B.; Vitiello, Benedetto; Breland-Noble, Alfiee; March, John S.
2007-01-01
Objective: To examine factors associated with eligibility and randomization and consider the efficiency of recruitment methods. Method: Adolescents, ages 12 to 17 years, were telephone screened (N = 2,804) followed by in-person evaluation (N = 1,088) for the Treatment for Adolescents With Depression Study. Separate logistic regression models,…
Role of the source to building lateral separation distance in petroleum vapor intrusion.
Verginelli, Iason; Capobianco, Oriana; Baciocchi, Renato
2016-06-01
The adoption of source to building separation distances to screen sites that need further field investigation is becoming a common practice for the evaluation of the vapor intrusion pathway at sites contaminated by petroleum hydrocarbons. Namely, for the source to building vertical distance, the screening criteria for petroleum vapor intrusion have been deeply investigated in the recent literature and fully addressed in the recent guidelines issued by ITRC and U.S.EPA. Conversely, due to the lack of field and modeling studies, the source to building lateral distance received relatively low attention. To address this issue, in this work we present a steady-state vapor intrusion analytical model incorporating a piecewise first-order aerobic biodegradation limited by oxygen availability that accounts for lateral source to building separation. The developed model can be used to evaluate the role and relevance of lateral vapor attenuation as well as to provide a site-specific assessment of the lateral screening distances needed to attenuate vapor concentrations to risk-based values. The simulation outcomes showed to be consistent with field data and 3-D numerical modeling results reported in previous studies and, for shallow sources, with the screening criteria recommended by U.S.EPA for the vertical separation distance. Indeed, although petroleum vapors can cover maximum lateral distances up to 25-30m, as highlighted by the comparison of model outputs with field evidences of vapor migration in the subsurface, simulation results by this new model indicated that, regardless of the source concentration and depth, 6m and 7m lateral distances are sufficient to attenuate petroleum vapors below risk-based values for groundwater and soil sources, respectively. However, for deep sources (>5m) and for low to moderate source concentrations (benzene concentrations lower than 5mg/L in groundwater and 0.5mg/kg in soil) the above criteria were found extremely conservative as the model results indicated that for such scenarios the lateral screening distance may be set equal to zero. Copyright © 2016 Elsevier B.V. All rights reserved.
Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A
2007-01-01
Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.
Screening for Bladder and Other Urothelial Cancers
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... recovery . There is no standard or routine screening test for bladder cancer. Screening for bladder cancer is under study and there are screening clinical trials taking place ...
An Alternative to Impedance Screening: Unoccluded Frontal Bone Conduction Screening.
ERIC Educational Resources Information Center
Square, Regina; And Others
1985-01-01
A bone conduction hearing screening test using frontal bone oscillator placement was compared with pure-tone air-conduction screening and impedance audiometry with 114 preschoolers. Unoccluded frontal bone conduction testing produced screening results not significantly different from results obtained by impedance audiometry. (CL)!
Use of clinical movement screening tests to predict injury in sport
Chimera, Nicole J; Warren, Meghan
2016-01-01
Clinical movement screening tests are gaining popularity as a means to determine injury risk and to implement training programs to prevent sport injury. While these screens are being used readily in the clinical field, it is only recently that some of these have started to gain attention from a research perspective. This limits applicability and poses questions to the validity, and in some cases the reliability, of the clinical movement tests as they relate to injury prediction, intervention, and prevention. This editorial will review the following clinical movement screening tests: Functional Movement Screen™, Star Excursion Balance Test, Y Balance Test, Drop Jump Screening Test, Landing Error Scoring System, and the Tuck Jump Analysis in regards to test administration, reliability, validity, factors that affect test performance, intervention programs, and usefulness for injury prediction. It is important to review the aforementioned factors for each of these clinical screening tests as this may help clinicians interpret the current body of literature. While each of these screening tests were developed by clinicians based on what appears to be clinical practice, this paper brings to light that this is a need for collaboration between clinicians and researchers to ensure validity of clinically meaningful tests so that they are used appropriately in future clinical practice. Further, this editorial may help to identify where the research is lacking and, thus, drive future research questions in regards to applicability and appropriateness of clinical movement screening tools. PMID:27114928
Hafez, Dina; Nelson, Daniel B; Martin, Evan G; Cohen, Alicia J; Northway, Rebecca; Kullgren, Jeffrey T
2017-04-04
Early diagnosis and treatment of prediabetes and type 2 diabetes mellitus (T2DM) can prevent future health problems, yet many individuals with these conditions are undiagnosed. This could be due, in part, to primary care physicians' (PCP) screening practices, about which little is known. The objectives of this study were to identify factors that influence PCPs' decisions to screen patients for T2DM and to characterize their interpretation and communication of screening test results to patients. We conducted semi-structured chart-stimulated recall interviews with 20 University of Michigan Health System (UMHS) primary care physicians. PCPs were asked about their recent decisions to screen or not screen 134 purposively sampled non-diabetic patients who met American Diabetes Association criteria for screening for T2DM. Interviews were audio-recorded, transcribed, and analyzed using qualitative directed content analysis. Data on patient demographic characteristics and comorbidities were abstracted from the electronic health record. The most common reasons PCPs gave for not screening 63 patients for T2DM were knowledge of a previously normal screening test (49%) and a visit for reasons other than a health maintenance examination (48%). The most common reasons PCPs gave for screening 71 patients for T2DM were knowledge of a previously abnormal screening test (49%), and patients' weight (42%) and age (38%). PCPs correctly interpreted 89% of screening test results and communicated 95% of test results to patients. Among 24 patients found to have prediabetes, PCPs usually (58%) recommended weight loss and increased physical activity but never recommended participation in a Diabetes Prevention Program or use of metformin. Previous screening test results, visit types, and patients' weight and age influenced PCPs' decisions to screen for T2DM. When patients were screened, test results were generally correctly interpreted and consistently communicated. Recommendations to patients with prediabetes could better reflect evidence-based strategies to prevent T2DM.
Reuland, Daniel S; Ko, Linda K; Fernandez, Alicia; Braswell, Laura C; Pignone, Michael
2012-06-12
Compared with non-Latinos, Latinos in the US have low rates of colorectal cancer (CRC) screening and low rates of knowledge regarding CRC screening tests and guidelines. Spanish speaking Latinos have particularly low CRC screening rates and screening knowledge. Our purpose was twofold: (1) to evaluate the effect of a computer-based, Spanish-language CRC screening decision aid on screening knowledge, intent to obtain screening, and screening self-efficacy in a community sample of Latinos with limited English proficiency (LEP); and (2) to survey these decision aid viewers at four months to determine their rates of CRC discussions with a health care provider as well as their rates of screening test completion. We recruited 50-75 year old Latinos with LEP who were not current with CRC. Participants screening viewed a 14 minute multimedia decision aid that addresses CRC screening rationale, recommendations, and options. We conducted an uncontrolled (pre-post) study in which we assessed screening knowledge, self-efficacy, and intent at baseline and immediately after decision aid viewing. We also conducted a follow-up telephone survey of participants at four months to examine rates of patient-provider screening discussions and test completion. Among n = 80 participants, knowledge scores increased from 20% (before) to 72% (after) decision aid viewing (absolute difference [95%CI]: 52% [46, 59]). The proportion with high screening self-efficacy increased from 67% to 92% (25% [13, 37]); the proportion with high screening intent increased from 63% to 95% (32% [21, 44]). We reached 68 (85%) of 80 participants eligible for the follow-up survey. Of these 36 (53%) reported discussing screening with a provider and 13 (19%) completed a test. Viewing a Spanish-language decision aid increased CRC screening knowledge, self-efficacy, and intent among Latinos with LEP. Decision aid viewing appeared to promote both CRC screening discussions with health care providers and test completion. The decision aid may be an effective tool for promoting CRC screening and reducing screening disparities in this population.
The value of the 4-day headdown bedrest model for screening countermeasures
NASA Technical Reports Server (NTRS)
Vernikos, J.; Keil, L.; Ertl, A. C.; Wade, C. E.; Greenleaf, J. E.; Ohara, D.; Ludwig, D.
1992-01-01
In order to evaluate the benefits of periodic exposure to the +G(z) vector as a countermeasure to the physiological responses to minus 6 degree head down bedrest (HDT), we considered a two-tiered approach: (a) to use 4 days HDT as a quick and inexpensive means of screening countermeasures, (b) to use a 60 day HDT to validate the most promising candidates. The approach and results of a 4 day study are described here. Methods: Nine males were admitted to our Human Research Facility for one ambulatory control day followed by 4 days HDT and were released on the next day after completion of a peak oxygen consumption test (VO(sub 2 peak)). A battery of tests was selected and standardized to evaluate the known early effects of HDT on plasma volume, early bone markers, orthostatic tolerance, physical performance, and fluid and electrolytes and their hormone regulation. Fluid sodium (Na) and potassium (K) intake and output in the urine were monitored throughout. Plasma volume was determined with a modified Evans Blue method and orthostatic tolerance with a 60 degree head-up tilt test for 30 minutes - both of which were determined on the ambulatory control day and on day 4 of HDT. Immediately after completion of the tilt test subjects were returned to the minus 6 degree position until the next morning when a VO(sub 2 peak) (horizontal ergometer) was done. This was compared to a similar control test determined on 2 separate occasions before subject admission. Results: Four hours after going HDT produced significant decreases (p less than 0.05) in the circulating concentration of fluid and electrolyte regulating hormones. Plasma volume, orthostatic tolerance and VO(sub 2 peak) changed significantly after 4 days HDT. There was also the expected natriuresis on day 1 of HDT but no significant diuresis. The consistency of the pre-bedrest VO(sub 2 peak) tilt tests and plasma volumes was remarkable. Conclusions: The 4 day HDT model seems highly promising for screening a variety of countermeasures alone and in combination before validating their benefits in extended bedrest or flight experiments.
ERIC Educational Resources Information Center
Fernandez, Mari T.; Marfo, Kofi
2005-01-01
Children's successful adjustment to child care involves effectively managing their separation from parents. Persistent problems with separation interfere with other relationships and with learning opportunities. The authors of this article developed a tool that caregivers can use to identify adjustment difficulties in young children who are …
USDA-ARS?s Scientific Manuscript database
A common screen for plant antimicrobial compounds consists of separating plant extracts by paper or thin-layer chromatography (PC or TLC), exposing the chromatograms to microbial suspensions (e.g. fungal spores in nutrient solution or bacteria in liquefied agar), allowing time for the microbes to gr...
Screenings are tests that look for diseases before you have symptoms. Screening tests can find diseases early, when they're easier ... Overweight and obesity Prostate cancer in men Which tests you need depends on your age, your sex, ...
... blood test Sigmoidoscopy Colonoscopy Virtual colonoscopy DNA stool test Studies have shown that screening for colorectal cancer using ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ...
What Screening Tests Are There?
... Women” Stay Informed Cancer Home What Screening Tests Are There? Language: English (US) Español (Spanish) Recommend on ... Screening means testing for a disease when there are no symptoms or history of that disease. Doctors ...
Flores, Yvonne N; Bishai, David M; Lorincz, Attila; Shah, Keerti V; Lazcano-Ponce, Eduardo; Hernández, Mauricio; Granados-García, Víctor; Pérez, Ruth; Salmerón, Jorge
2011-02-01
To determine the incremental costs and effects of different HPV testing strategies, when compared to Papanicolau cytology (Pap), for cervical cancer screening in Mexico. A cost-effectiveness analysis (CEA) examined the specific costs and health outcomes associated with (1) no screening; (2) only the Pap test; (3) only self-administered HPV; (4) only clinician administered HPV; and (5) clinician administered HPV plus the Pap test. The costs of self- and clinician-HPV testing, as well as with the Pap test, were identified and quantified. Costs were reported in 2008 US dollars. The health outcome associated with these screening strategies was defined as the number of high-grade cervical intraepithelial neoplasia or cervical cancer cases detected. This CEA was performed using the perspective of the Mexican Institute of Social Security (IMSS) in Morelos, Mexico. Screening women between the ages of 30-80 for cervical cancer using clinical-HPV testing or the combination of clinical-HPV testing, and the Pap is always more cost-effective than using the Pap test alone. This CEA indicates that HPV testing could be a cost-effective screening alternative for a large health delivery organization such as IMSS. These results may help policy-makers implement HPV testing as part of the IMSS cervical cancer screening program.
Bishai, David M.; Lőrincz, Attila; Shah, Keerti V.; Lazcano-Ponce, Eduardo; Hernández, Mauricio; Granados-García, Víctor; Pérez, Ruth; Salmerón, Jorge
2010-01-01
Objective To determine the incremental costs and effects of different HPV testing strategies, when compared to Papanicolau cytology (Pap), for cervical cancer screening in Mexico. Methods A cost-effectiveness analysis (CEA) examined the specific costs and health outcomes associated with (1) no screening; (2) only the Pap test; (3) only self-administered HPV; (4) only clinician administered HPV; and (5) clinician administered HPV plus the Pap test. The costs of self- and clinician-HPV testing, as well as with the Pap test, were identified and quantified. Costs were reported in 2008 US dollars. The health outcome associated with these screening strategies was defined as the number of high-grade cervical intraepithelial neoplasia or cervical cancer cases detected. This CEA was performed using the perspective of the Mexican Institute of Social Security (IMSS) in Morelos, Mexico. Results Screening women between the ages of 30–80 for cervical cancer using clinical-HPV testing or the combination of clinical-HPV testing, and the Pap is always more cost-effective than using the Pap test alone. Conclusions This CEA indicates that HPV testing could be a cost-effective screening alternative for a large health delivery organization such as IMSS. These results may help policy-makers implement HPV testing as part of the IMSS cervical cancer screening program. PMID:21170578
ROC and Loss Function Analysis in Sequential Testing
ERIC Educational Resources Information Center
Muijtjens, Arno M. M.; Van Luijk, Scheltus J.; Van Der Vleuten, Cees P. M.
2006-01-01
Sequential testing is applied to reduce costs in SP-based tests (OSCEs). Initially, all candidates take a screening test consisting of a part of the OSCE. Candidates who fail the screen sit the complete test, whereas those who pass the screen are qualified as a pass of the complete test. The procedure may result in a reduction of testing…
Separation Of Liquid And Gas In Zero Gravity
NASA Technical Reports Server (NTRS)
Howard, Frank S.; Fraser, Wilson S.
1991-01-01
Pair of reports describe scheme for separating liquid from gas so liquid could be pumped. Designed to operate in absence of gravitation. Jet of liquid, gas, or liquid/gas mixture fed circumferentially into cylindrical tank filled with liquid/gas mixture. Jet starts liquid swirling. Swirling motion centrifugally separates liquid from gas. Liquid then pumped from tank at point approximately diametrically opposite point of injection of jet. Vortex phase separator replaces such devices as bladders and screens. Requires no components inside tank. Pumps for gas and liquid outside tank and easily accessible for maintenance and repairs.
Hannon, Peggy A; Vu, Thuy; Ogdon, Sara; Fleury, Emily M; Yette, Emily; Wittenberg, Reva; Celedonia, Megan; Bowen, Deborah J
2013-03-01
Colorectal cancer screening is a life-saving intervention, but screening rates are low. The authors implemented and evaluated the Spokane Colorectal Cancer Screening Program-a novel worksite intervention to promote colorectal cancer screening that used a combination of evidence-based strategies recommended by the Guide to Community Preventive Services, as well as additional strategies. Over a period of approximately 3 months, participating worksites held one or more physician-led seminars about colorectal cancer screening for employees. They also distributed free fecal immunochemical tests at the worksite to employees 50 years and older, and they provided test results to employees and their primary care physician. The authors measured attendance at seminars, test kits taken and returned, employee awareness of the program, and colorectal cancer screening rates in participating and comparison worksites. It is estimated that 9% of eligible employees received kits at the worksite, and 4% were screened with these kits. The Spokane Colorectal Cancer Screening Program was a promising pilot test of an innovative worksite screening program that successfully translated evidence-based strategies into practical use in a brief period of time, and it merits a larger study to be able to test its effects more rigorously.
Palsetia, Delnaz; Rao, G. Prasad; Tiwari, Sarvada C.; Lodha, Pragya; De Sousa, Avinash
2018-01-01
There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated. PMID:29403122
Validity of screening tests for Sjögren's syndrome in ambulatory patients with chronic diseases.
Sánchez-Guerrero, Jorge; Pérez-Dosal, Marcia R; Celis-Aguilar, Erika; Cárdenas-Velázquez, Francisco; Soto-Rojas, Armando E; Avila-Casado, Carmen
2006-05-01
To determine the validity of screening tests for Sjogren's syndrome (SS) in ambulatory patients with chronic diseases. Three hundred randomly selected patients from the rheumatology and internal medicine clinics of a tertiary care center were assessed for SS according to the American-European Consensus Group criteria. During the screening phase, an interview, the European questionnaire for sicca symptoms, Schirmer-I test, and the wafer test were carried out in all patients. Patients with positive screening had confirmatory tests including fluorescein staining test, nonstimulated whole salivary flow, and autoantibody testing. Confirmatory tests were also done in 13 patients with negative screening. During the last phase, lip biopsy was proposed to patients who met preestablished criteria. Women made up 79% of the study population. Mean age of subjects was 42.8+/-15.7 years. Two hundred twenty patients (73%) had positive screening. The distribution of positive test results was: xerophthalmia 118 (39%), xerostomia 103 (34%), Schirmer-I test 101 (34%), and wafer test 187 (62%) patients. Forty (13%) patients met criteria for SS. All screening tests were useful for identifying patients with SS; however, the model composed of at least one positive response to the European questionnaire (EQ1), Schirmer-I test, and wafer test showed the best performance. Use of the European questionnaire, Schirmer-I test, and wafer test in parallel was useful for identifying patients with SS among ambulatory patients with chronic diseases.
Goldhaber-Fiebert, Jeremy D.; Stout, Natasha K.; Salomon, Joshua A.; Kuntz, Karen M.; Goldie, Sue J.
2011-01-01
Background The availability of human papillomavirus (HPV) DNA testing and vaccination against HPV types 16 and 18 (HPV-16,18) motivates questions about the cost-effectiveness of cervical cancer prevention in the United States for unvaccinated older women and for girls eligible for vaccination. Methods An empirically calibrated model was used to assess the quality-adjusted life years (QALYs), lifetime costs, and incremental cost-effectiveness ratios (2004 US dollars per QALY) of screening, vaccination of preadolescent girls, and vaccination combined with screening. Screening varied by initiation age (18, 21, or 25 years), interval (every 1, 2, 3, or 5 years), and test (HPV DNA testing of cervical specimens or cytologic evaluation of cervical cells with a Pap test). Testing strategies included: 1) cytology followed by HPV DNA testing for equivocal cytologic results (cytology with HPV test triage); 2) HPV DNA testing followed by cytology for positive HPV DNA results (HPV test with cytology triage); and 3) combined HPV DNA testing and cytology. Strategies were permitted to switch once at age 25, 30, or 35 years. Results For unvaccinated women, triennial cytology with HPV test triage, beginning by age 21 years and switching to HPV testing with cytology triage at age 30 years, cost $78 000 per QALY compared with the next best strategy. For girls vaccinated before age 12 years, this same strategy, beginning at age 25 years and switching at age 35 years, cost $41 000 per QALY with screening every 5 years and $188 000 per QALY screening triennially, each compared with the next best strategy. These strategies were more effective and cost-effective than screening women of all ages with cytology alone or cytology with HPV triage annually or biennially. Conclusions For both vaccinated and unvaccinated women, age-based screening by use of HPV DNA testing as a triage test for equivocal results in younger women and as a primary screening test in older women is expected to be more cost-effective than current screening recommendations. PMID:18314477
Tests Screening Reading Difficulty in Malayalam among Upper Primary School Boys
ERIC Educational Resources Information Center
Gafoor, K. Abdul
2014-01-01
Design of a screening test for identifying reading difficult students in Malayalam and validation thereof among boys is made to help schools proactively intervene with such students. A battery of tests developed based on extant literature on screening tests, reviewed difficulties in reading Malayalam, and discrimination power of the draft tests is…
Risks of Colorectal Cancer Screening
... blood test Sigmoidoscopy Colonoscopy Virtual colonoscopy DNA stool test Studies have shown that screening for colorectal cancer using ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ...
Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J
2017-07-01
This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years. Copyright © 2017 AGA Institute, American College of Gastroenterology, and the American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Cytology versus HPV testing for cervical cancer screening in the general population.
Koliopoulos, George; Nyaga, Victoria N; Santesso, Nancy; Bryant, Andrew; Martin-Hirsch, Pierre Pl; Mustafa, Reem A; Schünemann, Holger; Paraskevaidis, Evangelos; Arbyn, Marc
2017-08-10
Cervical cancer screening has traditionally been based on cervical cytology. Given the aetiological relationship between human papillomavirus (HPV) infection and cervical carcinogenesis, HPV testing has been proposed as an alternative screening test. To determine the diagnostic accuracy of HPV testing for detecting histologically confirmed cervical intraepithelial neoplasias (CIN) of grade 2 or worse (CIN 2+), including adenocarcinoma in situ, in women participating in primary cervical cancer screening; and how it compares to the accuracy of cytological testing (liquid-based and conventional) at various thresholds. We performed a systematic literature search of articles in MEDLINE and Embase (1992 to November 2015) containing quantitative data and handsearched the reference lists of retrieved articles. We included comparative test accuracy studies if all women received both HPV testing and cervical cytology followed by verification of the disease status with the reference standard, if positive for at least one screening test. The studies had to include women participating in a cervical cancer screening programme who were not being followed up for previous cytological abnormalities. We completed a 2 x 2 table with the number of true positives (TP), false positives (FP), true negatives (TN), and false negatives for each screening test (HPV test and cytology) used in each study. We calculated the absolute and relative sensitivities and the specificities of the tests for the detection of CIN 2+ and CIN 3+ at various thresholds and computed sensitivity (TP/(TP + TN) and specificity (TN/ (TN + FP) for each test separately. Relative sensitivity and specificity of one test compared to another test were defined as sensitivity of test-1 over sensitivity of test-2 and specificity of test-1 over specificity of test-2, respectively. To assess bias in the studies, we used the Quality Assessment of Diagnostic test Accuracy Studies (QUADAS) tool. We used a bivariate random-effects model for computing pooled accuracy estimates. This model takes into account the within- and between-study variability and the intrinsic correlation between sensitivity and specificity. We included a total of 40 studies in the review, with more than 140,000 women aged between 20 and 70 years old. Many studies were at low risk of bias. There were a sufficient number of included studies with adequate methodology to perform the following test comparisons: hybrid capture 2 (HC2) (1 pg/mL threshold) versus conventional cytology (CC) (atypical squamous cells of undetermined significance (ASCUS)+ and low-grade squamous intraepithelial lesions (LSIL)+ thresholds) or liquid-based cytology (LBC) (ASCUS+ and LSIL+ thresholds), other high-risk HPV tests versus conventional cytology (ASCUS+ and LSIL+ thresholds) or LBC (ASCUS+ and LSIL+ thresholds). For CIN 2+, pooled sensitivity estimates for HC2, CC and LBC (ASCUS+) were 89.9%, 62.5% and 72.9%, respectively, and pooled specificity estimates were 89.9%, 96.6%, and 90.3%, respectively. The results did not differ by age of women (less than or greater than 30 years old), or in studies with verification bias. Accuracy of HC2 was, however, greater in European countries compared to other countries. The results for the sensitivity of the tests were heterogeneous ranging from 52% to 94% for LBC, and 61% to 100% for HC2. Overall, the quality of the evidence for the sensitivity of the tests was moderate, and high for the specificity.The relative sensitivity of HC2 versus CC for CIN 2+ was 1.52 (95% CI: 1.24 to 1.86) and the relative specificity 0.94 (95% CI: 0.92 to 0.96), and versus LBC for CIN 2+ was 1.18 (95% CI: 1.10 to 1.26) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). The relative sensitivity of HC2 versus CC for CIN 3+ was 1.46 (95% CI: 1.12 to 1.91) and the relative specificity 0.95 (95% CI: 0.93 to 0.97). The relative sensitivity of HC2 versus LBC for CIN 3+ was 1.17 (95% CI: 1.07 to 1.28) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). Whilst HPV tests are less likely to miss cases of CIN 2+ and CIN 3+, these tests do lead to more unnecessary referrals. However, a negative HPV test is more reassuring than a negative cytological test, as the cytological test has a greater chance of being falsely negative, which could lead to delays in receiving the appropriate treatment. Evidence from prospective longitudinal studies is needed to establish the relative clinical implications of these tests.
Failure analysis of a 3.5 inch, 50 ampere-hour nickel-hydrogen cell
NASA Technical Reports Server (NTRS)
Fuhr, Kenneth H.
1987-01-01
The 3.5 inch, 50 ampere-hour nickel-hydrogen cell was on a Low Earth Orbit (LEO) test regime and was being cycled at 10 C and 60 percent depth of discharge. At cycle number 511 the Automatic Control and Data Acquisition System (ACDAS) terminated the test when the end of discharge voltage dropped below the 1.00 volt cutoff. Upon removal of the stack assembly from the pressure vessel, portions of the zircar separator were found to be completely missing. Upon further examination portions of both the positive and negative plates were found to be missing from its substrate and several gas screens were damaged due to excessive heat which caused fusing. The postulated cause of failure is free electrolyte in the cell which caused oxygen channelization resulting in localized recombination which degraded the stack components.
Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka
2016-02-01
To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.
Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka
2016-01-01
Aim To present and evaluate a new screening protocol for amblyopia in preschool children. Methods Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. Results 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. Conclusion The ZAPS study used the most discriminative VA test with optotypes in lines as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia. PMID:26935612
Nsuami, M Jacques; Nsa, Musheni; Brennan, Christine; Cammarata, Catherine L; Martin, David H; Taylor, Stephanie N
2013-01-01
To describe the trends in chlamydia positivity among New Orleans high school students tested in a schoolwide screening between 1996 and 2005, and to determine factors associated with chlamydia positivity among students during the 10-year period. Between school years 1995-1996 and 2004-2005, students in New Orleans public high schools were tested for chlamydia using nucleic acid amplification tests (NAAT) in urine specimens (LCx assay until 1999-2000; BD assay from 2000-2001 to 2004-2005). For each year, we calculated chlamydia positivity by dividing the number of students testing positive by the total number of students tested. Data were analyzed separately by gender. Logistic regressions were performed to determine independent predictors of chlamydia positivity during the 10-year period. Between 1996 and 2005, the average chlamydia positivity was 7.0% (95% confidence interval 6.6-7.4) in boys and 13.1% (95% confidence interval 12.6-13.7) in girls (P < .001). Chlamydia detection increased with the switch from LCx to BD assay. In multivariate analyses, chlamydia positivity among boys and girls was significantly associated with age, black race, and gonorrhea coinfection. Additionally, positivity was significantly different by school year among boys (P = .03) and by NAAT used among girls (P = .008). The trends in chlamydia positivity observed between 1996 and 2005 more likely reflected a high and stable prevalence of chlamydia in the New Orleans school-age adolescent population. Any benefit of screening on individuals tested was likely to be mitigated by participants' uninterrupted social interactions with the dynamic forces that sustain the sexual transmission of chlamydia in the population. Copyright © 2013 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Clinicians' perceptions of the benefits and harms of prostate and colorectal cancer screening.
Elstad, Emily A; Sutkowi-Hemstreet, Anne; Sheridan, Stacey L; Vu, Maihan; Harris, Russell; Reyna, Valerie F; Rini, Christine; Earp, Jo Anne; Brewer, Noel T
2015-05-01
Clinicians' perceptions of screening benefits and harms influence their recommendations, which in turn shape patients' screening decisions. We sought to understand clinicians' perceptions of the benefits and harms of cancer screening by comparing 2 screening tests that differ in their balance of potential benefits to harms: colonoscopy, which results in net benefit for many adults, and prostate-specific antigen (PSA) testing, which may do more harm than good. In this cross-sectional study, 126 clinicians at 24 family/internal medicine practices completed surveys in which they listed and rated the magnitude of colonoscopy and PSA testing benefits and harms for a hypothetical 70-year-old male patient and then estimated the likelihood that these tests would cause harm and lengthen the life of 100 similar men in the next 10 years. We tested the hypothesis that the availability heuristic would explain the association of screening test to perceived likelihood of benefit/harm and a competing hypothesis that clinicians' gist of screening tests as good or bad would mediate this association. Clinicians perceived PSA testing to have a greater likelihood of harm and a lower likelihood of lengthening life relative to colonoscopy. Consistent with our gist hypothesis, these associations were mediated by clinicians' gist of screening (balance of perceived benefits to perceived harms). Generalizability beyond academic clinicians remains to be established. Targeting clinicians' gist of screening, for example through graphical displays that allow clinicians to make gist-based relative magnitude comparisons, may influence their risk perception and possibly reduce overrecommendation of screening. © The Author(s) 2015.
Feasibility of Utilizing Ethnic Beauty Salons for Cervical Cancer Screening Education
Carvallo, Mauricio; Lee, Eunice
2014-01-01
The purpose of this study was to assess the feasibility of using ethnic beauty salons to reach out to Vietnamese and Korean American women for cervical cancer screening education. Participants (N = 62) were conveniently recruited from ethnic beauty salons located in Albuquerque, NM. Two feasibility questionnaires were separately administered to cosmetologists and their customers. Findings support the view that ethnic beauty salons can be used as a gateway to reach out to these populations, and cosmetologists have the potential to operate as community lay health workers to deliver cervical cancer screening education aimed at reducing disparities in cervical cancer and screening to their ethnic customers. PMID:24698810
A framework provided an outline toward the proper evaluation of potential screening strategies.
Adriaensen, Wim J; Matheï, Cathy; Buntinx, Frank J; Arbyn, Marc
2013-06-01
Screening tests are often introduced into clinical practice without proper evaluation, despite the increasing awareness that screening is a double-edged sword that can lead to either net benefits or harms. Our objective was to develop a comprehensive framework for the evaluation of new screening strategies. Elaborating on the existing concepts proposed by experts, a stepwise framework is proposed to evaluate whether a potential screening test can be introduced as a screening strategy into clinical practice. The principle of screening strategy evaluation is illustrated for cervical cancer, which is a template for screening because of the existence of an easily detectable and treatable precursor lesion. The evaluation procedure consists of six consecutive steps. In steps 1-4, the technical accuracy, place of the test in the screening pathway, diagnostic accuracy, and longitudinal sensitivity and specificity of the screening test are assessed. In steps 5 and 6, the impact of the screening strategy on the patient and population levels, respectively, is evaluated. The framework incorporates a harm and benefit trade-off and cost-effectiveness analysis. Our framework provides an outline toward the proper evaluation of potential screening strategies before considering implementation. Copyright © 2013 Elsevier Inc. All rights reserved.
Knowledge and practice of iranians toward colorectal cancer, and barriers to screening.
Salimzadeh, Hamideh; Delavari, Alireza; Montazeri, Ali; Mirzazadeh, Ali
2012-01-01
Colorectal cancer (CRC) is the third most common malignancy in Iran. Limited data are available on knowledge and barriers in regard to CRC and screening tests in Iran. The aim of the study was to characterize knowledge, practice, and barriers toward CRC and its screening tests among an Iranian at-risk population. This cross-sectional study was conducted with participation of 200 individuals of both genders aged 50 years or older in a teaching hospital in Tehran, Iran. Data were collected via face-to-face interviews. A questionnaire containing demographics; knowledge about CRC and screening tests; screening practice; and reasons for not being screened was administered. The reliability alpha for knowledge items was 0.52. The age of the participants ranged from 50 to 83 years (mean 60.13). Overall, 11% of the respondents reported prior screening by either fecal occult blood test (6.5%) or colonoscopy (4.5%). The majority of individuals had poor knowledge although respondents with prior screening obtained slightly higher score in comparison with nonparticipants in screening (26.74 vs. 23.24; P<0.05). Four commonly cited reasons for not having CRC tests were "doctor did not recommend the test," "did not think it was needed," "never think of the test," and "no symptoms/problems" which were reported by 29%, 26%, 20%, and 17% of the participants, respectively. It is necessary to design appropriate educational interventions to increase the general population's knowledge about CRC and screening before implementing preventive programs in Iran.
RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia.
Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D; Smirnakis, Stelios; Aslanides, Ioannis M
2017-01-01
Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia.
RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia
Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D.; Smirnakis, Stelios; Aslanides, Ioannis M.
2017-01-01
Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia. PMID:28800632
Campos, Nicole G.; Castle, Philip E.; Wright, Thomas C.; Kim, Jane J.
2016-01-01
As cervical cancer screening programs are implemented in low-resource settings, protocols are needed to maximize health benefits under operational constraints. Our objective was to develop a framework for examining health and economic tradeoffs between screening test sensitivity, population coverage, and follow-up of screen-positive women, to help decision makers identify where program investments yield the greatest value. As an illustrative example, we used an individual-based Monte Carlo simulation model of the natural history of human papillomavirus (HPV) and cervical cancer calibrated to epidemiologic data from Uganda. We assumed once in a lifetime screening at age 35 with two-visit HPV DNA testing or one-visit visual inspection with acetic acid (VIA). We assessed the health and economic tradeoffs that arise between 1) test sensitivity and screening coverage; 2) test sensitivity and loss to follow-up (LTFU) of screen-positive women; and 3) test sensitivity, screening coverage, and LTFU simultaneously. The decline in health benefits associated with sacrificing HPV DNA test sensitivity by 20% (e.g., shifting from provider- to self-collection of specimens) could be offset by gains in coverage if coverage increased by at least 20%. When LTFU was 10%, two-visit HPV DNA testing with 80-90% sensitivity was more effective and more cost-effective than one-visit VIA with 40% sensitivity, and yielded greater health benefits than VIA even as VIA sensitivity increased to 60% and HPV test sensitivity declined to 70%. As LTFU increased, two-visit HPV DNA testing became more costly and less effective than one-visit VIA. Setting-specific data on achievable test sensitivity, coverage, follow-up rates, and programmatic costs are needed to guide programmatic decision making for cervical cancer screening. PMID:25943074
A comprehensive screen for volatile organic compounds in biological fluids.
Sharp, M E
2001-10-01
A headspace gas chromatographic (GC) screen for common volatile organic compounds in biological fluids is reported. Common GC phases, DB-1 and DB-WAX, with split injection provide separation and identification of more than 40 compounds in a single 20-min run. In addition, this method easily accommodates quantitation. The screen detects commonly encountered volatile compounds at levels below 4 mg%. A control mixture, providing qualitative and semiquantitative information, is described. For comparison, elution of the volatiles on a specialty phase, DB-624, is reported. This method is an expansion and modification of a screen that had been used for more than 20 years. During its first year of use, the expanded screen has proven to be advantageous in routine forensic casework.
A comparative review of developmental screening tests.
Glascoe, F P; Martin, E D; Humphrey, S
1990-10-01
Public Law 99-457 amends the Education of the Handicapped Act to include services for children from birth through 3 years. Inasmuch as detection and referral of children with developmental delays continues to reside largely with pediatricians and other health care professionals, developmental screening, using standardized tests, is increasingly important. To help physicians select from the array of instruments, 19 different screening tests were administered by a pediatrician and rated by a panel of pediatricians and a special educator. While the panel found few tests that fit within the time constraints of pediatric practice, several tests approached standards for educational and psychologic tests. These included the Battelle Developmental Inventory Screening Test, Infant Monitoring System, Developmental Indicators for Assessment of Learning-Revised, Screening Children for Related Early Educational Needs, and the Developmental Profile II.
A systematic review of screening questionnaires for childhood lead poisoning.
Ossiander, Eric M
2013-01-01
The Centers for Disease Control and Prevention encourages the use of risk factor questionnaires to screen children for lead poisoning. A majority of state health departments have formal lead screening guidelines that recommend health care providers use questionnaires. We conducted a systematic review to evaluate the ability of lead screening questionnaires to predict lead poisoning risk among children. Articles that reported the evaluation of a predesigned lead screening questionnaire were obtained by searching Medline/PubMed and by examining references of articles obtained through the online search. From each evaluation, we abstracted the number of children that were true positive, false positive, true negative, and false negative, according to the results of the screening questionnaire and the follow-up blood lead test. From these data, we calculated specificity and sensitivity of the questionnaire for each evaluation. Twenty articles met the inclusion criteria: these included 28 separate questionnaire evaluations. Among 17 evaluations of the 1991 Centers for Disease Control and Prevention questionnaire, sensitivity ranged from 0.25 to 0.87, specificity from 0.31 to 0.80, and accuracy (sum of sensitivity and specificity) from 0.74 to 1.39. The pooled mean estimates for this questionnaire were sensitivity 0.61 (95% confidence interval: 0.53-0.68); specificity 0.52 (0.45-0.60); accuracy 1.12 (1.06-1.18). Among 11 evaluations of all other questionnaires, sensitivity ranged from 0.43 to 0.90, specificity from 0.17 to 0.66, and accuracy from 0.94 to 1.27. For these questionnaires, the pooled mean estimates were sensitivity 0.76 (0.68-0.85), specificity 0.41 (0.33-0.49), and accuracy 1.12 (1.06-1.18). Lead screening questionnaires showed a wide range of sensitivity and specificity and performed little better than chance at predicting lead poisoning risk among children.
A model for routine hospital-wide HIV screening: lessons learned and public health implications.
Maxwell, Celia J; Sitapati, Amy M; Abdus-Salaam, Sayyida S; Scott, Victor; Martin, Marsha; Holt-Brockenbrough, Maya E; Retland, Nicole L
2010-12-01
Approximately 232700 (21%) of Americans are unaware of their HIV-seropositive status; this represents a potential for virus transmission. Revised recommendations from the Centers for Disease Control for HIV screening promote routine screening in the health care setting. We describe the implementation of a hospital-wide routine HIV screening program in the District of Columbia. Rapid HIV testing was conducted at Howard University Hospital on consenting patients at least 18 years of age using the OraSure OraQuick Advance Rapid HIV-1/2 Antibody Test. The study population includes Howard University Hospital patients who were offered HIV screening over a 12-month period at no cost. Screened patients received immediate test results and, for those patients found to be preliminarily reactive, confirmatory testing and linkage to care were offered. Of the 12836 patients who were offered testing, 7528 (58.6%) consented. Preliminary reactive test results were identified in 176 patients (2.3%). Overall, 45.5% were confirmed, of which 82.5% were confirmed positive. Screening protocol changes have led to 100% confirmation since implementation. Hospital-wide routine HIV screening is feasible and can be implemented effectively and efficiently. The HIV screening campaign instituted at Howard University Hospital identified a substantial number of HIV-positive individuals and provided critical connection to follow-up testing, counseling, and disease management services.
Spatial resolution test of a beam diagnostic system for DESIREE
NASA Astrophysics Data System (ADS)
Das, Susanta; Kallberg, A.
2010-11-01
A diagnostic system based on the observation of low energy ( ˜ 10 eV) secondary electrons (SE) produced by a beam, striking a metallic foil has been built to monitor and to cover the wide range of beam intensities and energies for Double ElectroStatic Ion Ring ExpEriment [1,2].The system consists of a Faraday cup to measure the beam current, a collimator with circular apertures of different diameters to measure the spatial resolution of the system, a beam profile monitoring system (BPMS), and a control unit. The BPMS, in turn, consists of an aluminim (Al) foil, a grid placed in front of the Al foil to accelerate the SE, position sensitive MCP, fluorescent screen, and a CCD camera to capture the images. The collimator contains a set of circular holes of different diameters and separations (d) between them. The collimator cuts out from the beam areas equal to the holes with separation d mm between the beams centers and creates well separated (distinguishable) narrow beams of approximately same intensity close to each other. A 10 keV proton beam was used. The spatial resolution of the system was tested for different Al plate and MCP voltages and resolution of better than 2 mm was achieved. Ref.: 1. K. Kruglov {et al}., NIM A 441 (2000) 595; 701 (2002) 193c, 2. MSL and Atomic Physics, Stockholm Univ.(www.msl.se, http://www.atom.physto.se/Cederquist/desiree/web/hc.html).
Impact of screening colonoscopy on outcomes in colorectal cancer.
Matsuda, Takahisa; Ono, Akiko; Kakugawa, Yasuo; Matsumoto, Minori; Saito, Yutaka
2015-10-01
Colorectal cancer is one of the most common cancers in both men and women worldwide and a good candidate for screening programs. There are two modalities of colorectal cancer screening: (i) population-based screening and (ii) opportunistic screening. The first one is based on organized, well-coordinated, monitored and established programs with a systematic invitation covering the entire target population. In contrast, opportunistic screening tests are offered to people who are being examined for other reasons. Recently, a variety of colorectal cancer screening tests have become available; each country should make a choice, based on national demographics and resources, on the screening method to be used. Fecal occult blood test, especially the fecal immunochemical test, would be the best modality for decreasing colorectal cancer mortality through population-based screening. In contrast, if the aim includes the early detection of colorectal cancer and adenomas, endoscopic methods are more appropriate. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chang, Sabrina C H; Woo, Jane S T; Gorzalka, Boris B; Brotto, Lori A
2010-03-01
Papanicolaou (Pap) testing rates among Chinese women remain low compared with their Caucasian counterparts despite extensive efforts to raise awareness of the importance of regular screening. We examined three potential predictors of Pap testing behaviour in Chinese women: acculturation, cervical cancer screening belief accuracy, and intergenerational transmission. Caucasian (n = 78) and Chinese (n = 93) female university students and their mothers completed questionnaires concerning acculturation, Pap testing beliefs, and behaviours. Ethnic group comparisons revealed that Chinese daughters and mothers had lower Pap testing rates and less accurate beliefs regarding cervical cancer screening. Among women who had had at least one Pap test, there was no ethnic difference in the proportion of women who adhered to the recommended screening frequency. Among the Chinese women, lower heritage acculturation was correlated with higher cancer screening belief accuracy in both the daughters and their mothers. Maternal Pap testing behaviour was predicted by level of cancer screening belief accuracy, whereas daughters' Pap testing behaviour was predicted by previous experience of sexual intercourse and heritage acculturation. No intergenerational transmission of Pap testing beliefs or behaviours was found. The accuracy of cancer screening beliefs, level of acculturation and experience of sexual intercourse may be predictors of Pap testing behaviour in Chinese women. Contrary to our prediction, we found no support for intergenerational transmission, suggesting that Pap testing beliefs and behaviours of Chinese women are independent of the beliefs and behaviours of their mothers.
Cheng, Mengxia; Chen, Zilin
2017-08-01
A trypsin immobilized enzyme microreactor was successfully prepared in capillary for studying enzyme kinetics of trypsin and online screening of trypsin inhibitors from traditional Chinese medicine through capillary electrophoresis. Trypsin was immobilized on the inner wall at the inlet of the capillary treated with polydopamine. The rest of the capillary was used as a separation channel. The parameters including the separation efficiency and the activity of immobilized trypsin were comprehensively evaluated. Under the optimal conditions, online screening of trypsin inhibitors each time can be carried out within 6 min. The Michaelis-Menten constant of immobilized trypsin was calculated to be 0.50 mM, which indicated high affinity of the immobilized trypsin for the substrate. The half-maximal inhibitory concentration of known inhibitor of benzamidine hydrochloride hydrate as a model inhibitor was 13.32 mM. The proposed method was successfully applied to screen trypsin inhibitors from 15 compounds of traditional Chinese medicine. It has been found that baicalin showed inhibitory potency. Molecular docking study well supported the experimental result by exhibiting molecular interaction between enzyme and inhibitors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Minkler, Paul E.; Stoll, Maria S.K.; Ingalls, Stephen T.; Kerner, Janos; Hoppel, Charles L.
2016-01-01
Tandem MS “profiling” of acylcarnitines and amino acids was conceived as a first-tier screening method, and its application to expanded newborn screening has been enormously successful. However, unlike amino acid screening (which uses amino acid analysis as its second-tier validation of screening results), acylcarnitine “profiling” also assumed the role of second-tier validation, due to the lack of a generally accepted second-tier acylcarnitine determination method. In this report, we present results from the application of our validated UHPLC-MS/MS second-tier method for the quantification of total carnitine, free carnitine, butyrobetaine, and acylcarnitines to patient samples with known diagnoses: malonic acidemia, short-chain acyl-CoA dehydrogenase deficiency (SCADD) or isobutyryl-CoA dehydrogenase deficiency (IBD), 3-methyl-crotonyl carboxylase deficiency (3-MCC) or β-ketothiolase deficiency (BKT), and methylmalonic acidemia (MMA). We demonstrate the assay’s ability to separate constitutional isomers and diastereomeric acylcarnitines and generate values with a high level of accuracy and precision. These capabilities are unavailable when using tandem MS “profiles”. We also show examples of research interest, where separation of acylcarnitine species and accurate and precise acylcarnitine quantification is necessary. PMID:26458767
Kasten, Shane A; Zulli, Steven; Jones, Jonathan L; Dephillipo, Thomas; Cerasoli, Douglas M
2014-01-01
Chemical warfare nerve agents (CWNAs) are extremely toxic organophosphorus compounds that contain a chiral phosphorus center. Undirected synthesis of G-type CWNAs produces stereoisomers of tabun, sarin, soman, and cyclosarin (GA, GB, GD, and GF, respectively). Analytical-scale methods were developed using a supercritical fluid chromatography (SFC) system in tandem with a mass spectrometer for the separation, quantitation, and isolation of individual stereoisomers of GA, GB, GD, and GF. Screening various chiral stationary phases (CSPs) for the capacity to provide full baseline separation of the CWNAs revealed that a Regis WhelkO1 (SS) column was capable of separating the enantiomers of GA, GB, and GF, with elution of the P(+) enantiomer preceding elution of the corresponding P(–) enantiomer; two WhelkO1 (SS) columns had to be connected in series to achieve complete baseline resolution. The four diastereomers of GD were also resolved using two tandem WhelkO1 (SS) columns, with complete baseline separation of the two P(+) epimers. A single WhelkO1 (RR) column with inverse stereochemistry resulted in baseline separation of the GD P(–) epimers. The analytical methods described can be scaled to allow isolation of individual stereoisomers to assist in screening and development of countermeasures to organophosphorus nerve agents. Chirality 26:817–824, 2014. © 2014 The Authors. Chirality published by John Wiley Periodicals, Inc. PMID:25298066
Mission, John F; Catov, Janet; Deihl, Tiffany E; Feghali, Maisa; Scifres, Christina
2017-11-01
To evaluate the prevalence of early diabetes screening in pregnancy, rates of abnormal diabetes test results before 24 weeks of gestation, and factors associated with early diabetes screening. This was a retrospective cohort study of all singleton deliveries from 2012 to 2014 among diverse clinical practices at a large academic medical center. We assessed rates of early (less than 24 weeks of gestation) and routine (at or beyond 24 weeks of gestation) diabetes screening, with abnormal test results defined using the Carpenter-Coustan criteria, a 50-g glucose challenge test result greater than 200 mg/dL, or a hemoglobin A1C level greater than 6.5%. Univariate and multivariate analyses were used to evaluate clinical and demographic determinants of screening and diagnosis. Overall, 1,420 of 11,331 (12.5%) women underwent early screening. Increasing body mass index (BMI) category, race, public insurance, history of gestational diabetes mellitus, a family history of diabetes, and chronic hypertension were associated with early screening. Early screening rates rose with increasing BMI category, but only 268 of 551 (48.6%) of women with class III obesity underwent early screening. Among those screened early, 2.0% of normal-weight women, 4.0% of overweight women, 4.2% of class I obese women, 3.8% of class II obese women, and 9.0% of class III obese women had abnormal early test results (P<.001). Early diabetes screening is used inconsistently, and many women with risk factors do not undergo early screening. A significant proportion of women with class III obesity will test positive for gestational diabetes mellitus before 24 weeks of gestation, and studies are urgently needed to assess the effect of early diabetes screening and diagnosis on perinatal outcomes in high-risk women.
Madonna, A.J.; Basile, F.; Furlong, E.; Voorhees, K.J.
2001-01-01
A rapid method for identifying specific bacteria from complex biological mixtures using immunomagnetic separation coupled to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been developed. The technique employs commercially available magnetic beads coated with polycolonal antibodies raised against specific bacteria and whole cell analysis by MALDI-MS. A suspension of a bacterial mixture is mixed with the immunomagnetic beads specific for the target microorganism. After a short incubation period (20 mins) the bacteria captured by the beads are washed, resuspended in deionized H2O and directly applied onto a MALDI probe. Liquid suspensions containing bacterial mixtures can be screened within 1 h total analysis time. Positive tests result in the production of a fingerprint mass spectrum primarily consisting of protein biomarkers characteristic of the targeted microorganism. Using this procedure, Salmonella choleraesuis was isolated and detected from standard bacterial mixtures and spiked samples of river water, human urine, and chicken blood. Copyright ?? 2001 John Wiley & Sons, Ltd.
Chiemchaisri, Chart; Charnnok, Boonya; Visvanathan, Chettiyappan
2010-03-01
An effort to utilize solid wastes at dumpsite as refuse-derived fuel (RDF) was carried out. The produced RDF briquette was then utilized in the gasification system. These wastes were initially examined for their physical composition and chemical characteristics. The wastes contained high plastic content of 24.6-44.8%, majority in polyethylene plastic bag form. The plastic wastes were purified by separating them from other components through manual separation and trommel screen after which their content increased to 82.9-89.7%. Subsequently, they were mixed with binding agent (cassava root) and transformed into RDF briquette. Maximum plastic content in RDF briquette was limit to 55% to maintain physical strength and maximum chlorine content. The RDF briquette was tested in a down-draft gasifier. The produced gas contained average energy content of 1.76 MJ/m(3), yielding cold gas efficiency of 66%. The energy production cost from this RDF process was estimated as USD0.05 perkWh. 2009 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carmichael, Joshua D.; Hartse, Hans
Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannelmore » waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.« less
Identifiability in N-mixture models: a large-scale screening test with bird data.
Kéry, Marc
2018-02-01
Binomial N-mixture models have proven very useful in ecology, conservation, and monitoring: they allow estimation and modeling of abundance separately from detection probability using simple counts. Recently, doubts about parameter identifiability have been voiced. I conducted a large-scale screening test with 137 bird data sets from 2,037 sites. I found virtually no identifiability problems for Poisson and zero-inflated Poisson (ZIP) binomial N-mixture models, but negative-binomial (NB) models had problems in 25% of all data sets. The corresponding multinomial N-mixture models had no problems. Parameter estimates under Poisson and ZIP binomial and multinomial N-mixture models were extremely similar. Identifiability problems became a little more frequent with smaller sample sizes (267 and 50 sites), but were unaffected by whether the models did or did not include covariates. Hence, binomial N-mixture model parameters with Poisson and ZIP mixtures typically appeared identifiable. In contrast, NB mixtures were often unidentifiable, which is worrying since these were often selected by Akaike's information criterion. Identifiability of binomial N-mixture models should always be checked. If problems are found, simpler models, integrated models that combine different observation models or the use of external information via informative priors or penalized likelihoods, may help. © 2017 by the Ecological Society of America.
Chen, Yisheng; Schwack, Wolfgang
2014-08-22
The world-wide usage and partly abuse of veterinary antibiotics resulted in a pressing need to control residues in animal-derived foods. Large-scale screening for residues of antibiotics is typically performed by microbial agar diffusion tests. This work employing high-performance thin-layer chromatography (HPTLC) combined with bioautography and electrospray ionization mass spectrometry introduces a rapid and efficient method for a multi-class screening of antibiotic residues. The viability of the bioluminescent bacterium Aliivibrio fischeri to the studied antibiotics (16 species of 5 groups) was optimized on amino plates, enabling detection sensitivity down to the strictest maximum residue limits. The HPTLC method was developed not to separate the individual antibiotics, but for cleanup of sample extracts. The studied antibiotics either remained at the start zones (tetracyclines, aminoglycosides, fluoroquinolones, and macrolides) or migrated into the front (amphenicols), while interfering co-extracted matrix compounds were dispersed at hRf 20-80. Only after a few hours, the multi-sample plate image clearly revealed the presence or absence of antibiotic residues. Moreover, molecular information as to the suspected findings was rapidly achieved by HPTLC-mass spectrometry. Showing remarkable sensitivity and matrix-tolerance, the established method was successfully applied to milk and kidney samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Yuan-Ting; Li, Da-Wei; Song, Wei; Long, Yi-Tao
2011-02-01
A disposable electrode, multi-walled carbon nanotube modified screen printed electrode (MWCNT/SPE), had been fabricated using screen printing technology and drop-coating method to determine dihydroxybenzene isomers (hydroquinone, catechol and resorcinol). The cyclic voltammetry behavior of dihydroxybenzene isomers had been investigated with the MWCNT/SPE. The results reveal that MWCNT/SPE, which shows a strong electrocatalytic activity for the oxidation of dihydroxybenzenes, can entirely separate the oxidation peaks of them. According to differential pulse voltammetry tests, the peak currents of dihydroxybenzene isomers are linear to their concentrations at the range of 8.20 x 10(-6) -1.00 x 10(-3), 8.20 x 10(-6) -1.00 x 10(-3) and 1.64 x 10(-5) -1.16 x 10(-3) mol x L(-1), with the detection limits of 4.34 x 10(-6), 3.42 x 10(-6) and 6.70 x 10(-6) mol x L(-1) for hydroquinone, catechol and resorcinol, respectively. For the determination of dihydroxybenzene isomers in water samples, the value of recovery found by standard addition method was in the range of 96.2%-104.9%. These results indicate MWCNT/SPE can be applied to rapid in-situ determination of dihydroxybenzenes-polluted water samples.
Mandal, Shreya; Patra, Arpita; Samanta, Animesh; Roy, Suchismita; Mandal, Arpita; Mahapatra, Tapasi Das; Pradhan, Shrabani; Das, Koushik; Nandi, Dilip Kumar
2013-12-01
To investigate phytochemical screening, antimicrobial activity and qualitative thin layer chromatographic separation of flavonoid components, antioxidant activity and total flavonoid compound of Terminalia arjuna. For phytochemical screening, some common and available standard tests were done. Antimicrobial bioassay was done through agar well diffusion method. Detection of antioxidant activity and flavonoid compounds were done through thin layer chromatography. Total antioxidant activity was measured by 2, 2-diphenyl-1-picrylhydrazyl (DPPH) in colorimetric method. Aluminum chloride colorimetric method was used for total flavonoid determination. Phytochemical screening showed the active compounds presence in high concentration, such as phytosterol, lactones, flavonoids, phenolic compounds and tannins and glycosides. The antimicrobial activity of extract showed that greater inhibition zone against Gram negative bacteria than Gram positive bacteria. This methanolic extract showed a promising antioxidant activity, as absorption of DPPH redicles decreased in DPPH free radical scavenging assay. Flavonoids components having antioxidant property present in the methanol extract at a level of 199.00 mg quercetin equivalent/g of dried methanol extract in colorimetric method. The Terminalia arjuna bark extract revealed the presence of bio-active constituents which are known to exhibit medicinal as well as physiological activities. Copyright © 2013 Asian Pacific Tropical Biomedical Magazine. Published by Elsevier B.V. All rights reserved.
Nakai, Ryuichiro; Salisbury, Cleo M; Rosen, Hugh; Cravatt, Benjamin F
2009-02-01
High-throughput screening (HTS) has become an integral part of academic and industrial efforts aimed at developing new chemical probes and drugs. These screens typically generate several 'hits', or lead active compounds, that must be prioritized for follow-up medicinal chemistry studies. Among primary considerations for ranking lead compounds is selectivity for the intended target, especially among mechanistically related proteins. Here, we show how the chemical proteomic technology activity-based protein profiling (ABPP) can serve as a universal assay to rank HTS hits based on their selectivity across many members of an enzyme superfamily. As a case study, four metalloproteinase-13 (MMP13) inhibitors of similar potency originating from a publically supported HTS and reported in PubChem were tested by ABPP for selectivity against a panel of 27 diverse metalloproteases. The inhibitors could be readily separated into two groups: (1) those that were active against several metalloproteases and (2) those that showed high selectivity for MMP13. The latter set of inhibitors was thereby designated as more suitable for future medicinal chemistry optimization. We anticipate that ABPP will find general utility as a platform to rank the selectivity of lead compounds emerging from HTS assays for a wide variety of enzymes.
Aboud, Maurice J; Gassmann, Marcus; McCord, Bruce
2015-09-01
There are situations in which it is important to quickly and positively identify an individual. Examples include suspects detained in the neighborhood of a bombing or terrorist incident, individuals detained attempting to enter or leave the country, and victims of mass disasters. Systems utilized for these purposes must be fast, portable, and easy to maintain. DNA typing methods provide the best biometric information yielding identity, kinship, and geographical origin, but they are not portable and rapid. This study details the development of a portable short-channel microfluidic device based on a modified Agilent 2100 bioanalyzer for applications in forensic genomics. The system utilizes a denaturing polymer matrix with dual-channel laser-induced fluorescence and is capable of producing a genotype in 80 sec. The device was tested for precision and resolution using an allelic ladder created from 6 short tandem repeat (STR) loci and a sex marker (amelogenin). The results demonstrated a precision of 0.09-0.21 bp over the entire size range and resolution values from 2.5 to 4.1 bp. Overall, the results demonstrate the chip provides a portable, rapid, and precise method for screening amplified short tandem repeats and human identification screening. © 2015 American Academy of Forensic Sciences.
NASA Astrophysics Data System (ADS)
Liao, Fadian; Ruan, Qiuyong; Lin, Juqiang; Lin, Jinyong; Zeng, Yongyi; Li, Ling; Huang, Zufang; Liu, Nenrong; Chen, Rong
2014-09-01
Despite the introduction of high-technology methods of detection and diagnosis, screening of primary liver cancer (PLC) remains imperfect. To diagnosis PLC earlier, Surface-enhanced Raman spectroscopy (SERS) coupled with cellulose-acetate membrane electrophoresis were introduced to separate human serum albumin and SERS spectra. Three groups (15 normal persons' samples, 17 hepatitis/cirrhosis samples, 15 cases of PLC) of serum albumin were tested. Silver colloid was used to obtain SERS spectra of human serum albumin. Principal component analysis (PCA) and linear discriminant analysis (LDA) were also employed for statistical analysis. The mean Raman spectra of three groups and the difference spectra of any two suggested that the albumin has changed in liver patients. Compared to normal groups, some Raman peaks have shifted or even disappeared in hepatitis/cirrhosis and PLCs groups. The sensitivity and specificity between PLCs and normal groups is 80% and 93.3%. Among hepatitis/cirrhosis and normal groups, the sensitivity is 88.2% and specificity is also 93.3%. Besides, the sensitivity and specificity between PLCs and hepatitis/cirrhosis groups is 86.7% and 76.5%. All the above data and results indicated that early screening of PLC is potential by SERS in different stages of liver disease before cancer occurs.
Zhao, X L; Remila, Rezhake; Hu, S Y; Zhang, L; Xu, X Q; Chen, F; Pan, Q J; Zhang, X; Zhao, F H
2018-05-06
Objective: To evaluate and compare the screening performance of primary high-risk HPV(HR-HPV) screening and HR-HPV screening plus liquid-based cytology (LBC) cotesting in diagnosis of cervical cancer and precancerous lesions (CIN2+). Methods: We pooled 17 population-based cross-sectional studies which were conducted across China from 1999 to 2008. After obtaining informed consent, all women received liquid-based cytology(LBC)testing, HR-HPV DNA testing. Totally 28 777 women with complete LBC, HPV and biopsy results were included in the final analysis. Screening performance of primary HR-HPV DNA screening and HPV screening plus LBC co-testing in diagnosis of CIN2+ were calculated and compared among different age groups. Results: Among the whole population, the detection rates of primary HR-HPV screening and HR-HPV screening plus LBC co-testing are 3.05% (879 CIN2+) and 3.13%(900 CIN2+), respectively. The sensitivity were 96.4% and 98.7% (χ(2)=19.00, P< 0.001), and the specificity were 86.2% and 78.8% (χ(2)=2 067.00, P< 0.001), respectively. Areas under the receiver operating characteristic (ROC) curve (AUC) showed that the primary HR-HPV screening performed better than co-testing (AUC were 0.913 and 0.888; Z= 6.16, P< 0.001). Compared with primary HR-HPV screening, co-testing showed significantly higher colposcopy referral rates (16.5% and 23.6%, respectively, χ(2)=132.00, P< 0.001) and the number of colposcopy examination for detecting per CIN2+ (5.4 and 7.6, respectively).In the group aged 25-29, the colposcopy referral rates was 8.7 (10.9%(199 cases) vs 1.3%(23 cases)) times as much as the detection rate of primary HR-HPV screening in diagnosis of CIN2+, and was 12.5 (15.7%(288 cases) vs 1.3%(23 cases)) times as much as the detection rate of HR-HPV screening plus cytology contesting. Conclusion: Compared with primary HR-HPV screening, HR-HPV screening plus cytology co-testing does not show better results in the screening performance for CIN2+ detection, and the cost-effectiveness is not good enough, especially in younger age group.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, Wenwan
2003-01-01
Capillary electrophoresis (CE) offers many advantages over conventional analytical methods, such as speed, simplicity, high resolution, low cost, and small sample consumption, especially for the separation of enantiomers. However, chiral method developments still can be time consuming and tedious. They designed a comprehensive enantioseparation protocol employing neutral and sulfated cyclodextrins as chiral selectors for common basic, neutral, and acidic compounds with a 96-capillary array system. By using only four judiciously chosen separation buffers, successful enantioseparations were achieved for 49 out of 54 test compounds spanning a large variety of pKs and structures. Therefore, unknown compounds can be screened in thismore » manner to identify optimal enantioselective conditions in just one rn. In addition to superior separation efficiency for small molecules, CE is also the most powerful technique for DNA separations. Using the same multiplexed capillary system with UV absorption detection, the sequence of a short DNA template can be acquired without any dye-labels. Two internal standards were utilized to adjust the migration time variations among capillaries, so that the four electropherograms for the A, T, C, G Sanger reactions can be aligned and base calling can be completed with a high level of confidence. the CE separation of DNA can be applied to study differential gene expression as well. Combined with pattern recognition techniques, small variations among electropherograms obtained by the separation of cDNA fragments produced from the total RNA samples of different human tissues can be revealed. These variations reflect the differences in total RNA expression among tissues. Thus, this Ce-based approach can serve as an alternative to the DNA array techniques in gene expression analysis.« less
Carozzi, Francesca Maria; Bisanzi, Simonetta; Carrozzi, Laura; Falaschi, Fabio; Lopes Pegna, Andrea; Mascalchi, Mario; Picozzi, Giulia; Peluso, Marco; Sani, Cristina; Greco, Luana; Ocello, Cristina; Paci, Eugenio
2017-07-01
Asymptomatic high-risk subjects, randomized in the intervention arm of the ITALUNG trial (1,406 screened for lung cancer), were enrolled for the ITALUNG biomarker study (n = 1,356), in which samples of blood and sputum were analyzed for plasma DNA quantification (cut off 5 ng/ml), loss of heterozygosity and microsatellite instability. The ITALUNG biomarker panel (IBP) was considered positive if at least one of the two biomarkers included in the panel was positive. Subjects with and without lung cancer diagnosis at the end of the screening cycle with LDCT (n = 517) were evaluated. Out of 18 baseline screen detected lung cancer cases, 17 were IBP positive (94%). Repeat screen-detected lung cancer cases were 18 and 12 of them positive at baseline IBP test (66%). Interval cancer cases (2-years) and biomarker tests after a suspect Non Calcific Nodule follow-up were investigated. The single test versus multimodal screening measures of accuracy were compared in a simulation within the screened ITALUNG intervention arm, considering screen-detected and interval cancer cases. Sensitivity was 90% at baseline screening. Specificity was 71 and 61% for LDCT and IBP as baseline single test, and improved at 89% with multimodal, combined screening. The positive predictive value was 4.3% for LDCT at baseline and 10.6% for multimodal screening. Multimodal screening could improve the screening efficiency at baseline and strategies for future implementation are discussed. If IBP was used as primary screening test, the LDCT burden might decrease of about 60%. © 2017 UICC.
Lin, K T; Chang, C L; Tsai, M H; Lin, K S; Saldanha, J; Hung, C M
2014-02-01
The ability of a new generation commercial, multiplex, multi-dye test from Roche, the cobas TaqScreen MPX test, version 2.0, to detect and identify occult HBV infections was evaluated using routine donor samples from Kaohsiung Blood Bank, Taiwan. A total of 5973 samples were tested by nucleic acid amplification technology (NAT); 5898 in pools of six, 66 in pools of less than six and nine samples individually. NAT-reactive samples were retested with alternative NAT tests, and follow-up samples from the donors were tested individually by NAT and for all the HBV serological markers. Eight NAT-only-reactive donors were identified, and follow-up samples were obtained from six of the donors. The results indicated that all eight donors had an occult HBV infection with viral loads <12 IU/ml. The cobas(®) TaqScreen MPX test, version 2.0, has an advantage over the current Roche blood screening test, the cobas TaqScreen MPX test, for screening donations in countries with a high prevalence of occult HBV infections since the uncertainty associated with identifying samples with very low viremia is removed by the ability of the test to identify the viral target in samples that are reactive with the cobas TaqScreen MPX test, version 2.0. © 2013 International Society of Blood Transfusion.
Li, Senlin; Li, Sainan; Huang, Yu; Liu, Chunming; Chen, Lina; Zhang, Yuchi
2017-06-01
The separation of a compound of interest from its structurally similar homologues to produce high-purity natural products is a challenging problem. This work proposes a novel method for the separation of iristectorigenin A from its structurally similar homologues by ionic-liquid-based ultrasound-assisted extraction and the subsequent screening and isolation of potential α-glucosidase inhibitors via ultrafiltration and semipreparative high-performance liquid chromatography. Ionic-liquid-based ultrasound-assisted extraction was successfully applied to the extraction of tectorigenin, iristectorigenin A, irigenin, and irisflorentin from Belamcanda chinensis. The optimum conditions for the efficient extraction of isoflavones were determined as 1.0 M 1-ethyl-3-methylimidazolium tetrafluoroborate with extraction time of 30 min and a solvent to solid ratio of 30 mL/g. Ultrafiltration with liquid chromatography and mass spectrometry was applied to screen and identify α-glucosidase inhibitors from B. chinensis, followed by the application of semipreparative high-performance liquid chromatography to separate and isolate the active constituents. Four major compounds including tectorigenin, iristectorigenin A, irigenin, and irisflorentin were screened and identified as α-glucosidase inhibitors, and then the four active compounds abovementioned were subsequently isolated by semipreparative high-performance liquid chromatography (99.89, 88.97, 99.79, and 99.97% purity, respectively). The results demonstrate that ionic liquid extraction can be successfully applied to the extraction of isoflavones from B. chinensis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
COVD-QOL questionnaire: An adaptation for school vision screening using Rasch analysis
Abu Bakar, Nurul Farhana; Ai Hong, Chen; Pik Pin, Goh
2012-01-01
Purpose To adapt the College of Optometrist in Vision Development (COVD-QOL) questionnaire as a vision screening tool for primary school children. Methods An interview session was conducted with children, teachers or guardians regarding visual symptoms of 88 children (45 from special education classes and 43 from mainstream classes) in government primary schools. Data was assessed for response categories, fit items (infit/outfit: 0.6–1.4) and separation reliability (item/person: 0.80). The COVD-QOL questionnaire results were compared with vision assessment in identifying three categories of vision disorders: reduce visual acuity, accommodative response anomaly and convergence insufficiency. Analysis on the screening performance using the simplified version of the questionnaire was evaluated based on receiver-operating characteristic analysis for detection of any type of target conditions for both types of classes. Predictive validity analysis was used a Spearman rank correlation (>0.3). Results Two of the response categories were underutilized and therefore collapsed to the adjacent category and items were reduced to 14. Item separation reliability for the simplified version of the questionnaire was acceptable (0.86) but the person separation reliability was inadequate for special education classes (0.79) similar to mainstream classes (0.78). The discriminant cut-off score of 9 (mainstream classes) and 3 (special education classes) from the 14 items provided sensitivity and specificity of (65% and 54%) and (78% and 80%) with Spearman rank correlation of 0.16 and 0.40 respectively. Conclusion The simplified version of COVD-QOL questionnaire (14-items) performs adequately among children in special education classes suggesting its suitability as a vision screening tool.
Savage, George M.
1991-01-01
Apparatus for separating material into first and second portions according to size including a plurality of shafts, a plurality of spaced disks radiating outwardly from each of the shafts to define apertures and linkage interconnecting the shafts for moving the shafts toward or away from one another to vary the size of the apertures while the apparatus is performing the separating function.
Physiologic Screening Test for Eating Disorders/Disordered Eating Among Female Collegiate Athletes.
Black, David R.; Larkin, Laurie J.S.; Coster, Daniel C.; Leverenz, Larry J.; Abood, Doris A.
2003-12-01
OBJECTIVE: To develop and evaluate a physiologic screening test specifically designed for collegiate female athletes engaged in athletic competition or highly athletic performances in order to detect eating disorders/disordered eating. No such physiologically based test currently exists. METHODS: Subjects included 148 (84.5%) of 175 volunteer, National Collegiate Athletic Association Division I (n = 92), club (n = 15), and dance team (n = 41) athletes 18 to 25 years old who attended a large, Midwestern university. Participants completed 4 tests: 2 normed for the general population (Eating Disorders Inventory-2 and Bulimia Test-Revised); a new physiologic test, developed and pilot tested by the investigators, called the Physiologic Screening Test; and the Eating Disorder Exam 12.0D, a structured, validated, diagnostic interview used for criterion validity. RESULTS: The 18-item Physiologic Screening Test produced the highest sensitivity (87%) and specificity (78%) and was superior to the Eating Disorders Inventory-2 (sensitivity = 62%, specificity = 74%) and Bulimia Test-Revised (sensitivity = 27%, specificity = 99%). A substantial number (n = 51, 35%) of athletes were classified as eating disordered/disordered eating. CONCLUSIONS: The Physiologic Screening Test should be considered for screening athletes for eating disorders/disordered eating. The Physiologic Screening Test seems to be a viable alternative to existing tests because it is specifically designed for female athletes, it is brief (4 measurements and 14 items), and validity is enhanced and response bias is lessened because the purpose is less obvious, especially when included as part of a mandatory preparticipation examination.
Taubman, Danielle; Titler, Nava; Edelstein, Hana; Elias, Mazen; Saliba, Walid
2013-12-01
The compliance of screening for latent tuberculosis (TB) with the tuberculin purified protein derivative (PPD) test is very low among healthcare workers (HCWs) in Israel. This randomized controlled study uses the Health Belief Model (HBM) as a conceptual framework to examine whether providing more information about latent TB and the PPD test increases the response rate for PPD screening among HCWs. All candidate HCWs for latent TB screening were randomly allocated to one of the following two invitations to perform the PPD test: regular letter (control group, n=97), and a letter with information about latent TB and the PPD test (intervention group, n=196). 293 HCWs were included (185 nurses, and 108 physicians). Overall, 36 (12.3%) HCWs were compliant with the PPD test screening. Compliance with PPD testing in the intervention group was not statistically different from the control group, RR 0.87 (95% CI, 0.46-1.65). Compliance for latent TB screening is low among HCWs in northeastern Israel. Providing detailed information about latent TB was not associated with increased test compliance. Understanding existing disparities in screening rates and potential barriers to latent TB screening among HCWs is important in order to move forward and successfully increase screening rates. Copyright © 2013 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.
Christy, Shannon M; Schmidt, Alyssa; Wang, Hsiao-Lan; Sutton, Steven K; Davis, Stacy N; Chavarria, Enmanuel; Abdulla, Rania; Quinn, Gwendolyn P; Vadaparampil, Susan T; Schultz, Ida; Roetzheim, Richard; Shibata, David; Meade, Cathy D; Gwede, Clement K
2018-06-04
To reduce colorectal cancer (CRC) screening disparities, it is important to understand correlates of different types of cancer worry among ethnically diverse individuals. The current study examined the prevalence of three types of cancer worry (i.e., general cancer worry, CRC-specific worry, and worry about CRC test results) as well as sociodemographic and health-related predictors for each type of cancer worry. Participants were aged 50-75, at average CRC risk, nonadherent to CRC screening guidelines, and enrolled in a randomized controlled trial to increase CRC screening. Participants completed a baseline questionnaire assessing sociodemographics, health beliefs, healthcare experiences, and three cancer worry measures. Associations between study variables were examined with separate univariate and multivariable logistic regression models. Responses from a total of 416 participants were used. Of these, 47% reported experiencing moderate-to-high levels of general cancer worry. Predictors of general cancer worry were salience and coherence (aOR = 1.1, 95% CI [1.0, 1.3]), perceived susceptibility (aOR = 1.2, 95% CI [1.1, 1.3), and social influence (aOR = 1.1, 95% CI [1.0, 0.1]). Fewer (23%) reported moderate-to-high levels of CRC-specific worry or CRC test worry (35%). Predictors of CRC worry were perceived susceptibility (aOR = 1.4, 95% CI [1.3, 1.6]) and social influence (aOR = 1.1, 95% CI [1.0, 1.2]); predictors of CRC test result worry were perceived susceptibility (aOR = 1.2, 95% CI [1.1, 1.3) and marital status (aOR = 2.0, 95% CI [1.1, 3.7] for married/partnered vs. single and aOR = 2.3, 95% CI [1.3, 4.1] for divorced/widowed vs. single). Perceived susceptibility consistently predicted the three types of cancer worry, whereas other predictors varied between cancer worry types and in magnitude of association. The three types of cancer worry were generally predicted by health beliefs, suggesting potential malleability. Future research should include multiple measures of cancer worry and clear definitions of how cancer worry is measured.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage
A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less
Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage; ...
2018-05-09
A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less
Weiss, Noel S; Dhillon, Preet K; Etzioni, Ruth
2004-07-01
A case-control study of the efficacy of cancer screening, like any other case-control study, must deal with potential confounding. There are 2 categories of confounding variables that pose special problems for studies of screening: (1) age and calendar time resulting from different temporal distributions of screening between cases and controls irrespective of whether the screening test leads to a reduction in mortality; and (2) the administration of other screening tests for the cancer in question when it is not clear whether the result of the other test had a bearing on the decision to order the test under study. We describe circumstances in which confounding from these sources can be dealt with satisfactorily by means of restriction or adjustment, and other circumstances in which it cannot. Copyright 2004 Lippincott Williams and Wilkins
Color vision testing with a computer graphics system: preliminary results.
Arden, G; Gündüz, K; Perry, S
1988-06-01
We report a method for computer enhancement of color vision tests. In our graphics system 256 colors are selected from a much larger range and displayed on a screen divided into 768 x 288 pixels. Eight-bit digital-to-analogue converters drive a high quality monitor with separate inputs to the red, green, and blue amplifiers and calibrated gun chromaticities. The graphics are controlled by a PASCAL program written for a personal computer, which calculates the values of the red, green, and blue signals and specifies them in Commité Internationale d'Eclairage X, Y, and Z fundamentals, so changes in chrominance occur without changes in luminance. The system for measuring color contrast thresholds with gratings is more than adequate in normal observers. In patients with mild retinal damage in whom other tests of visual function are normal, this method of testing color vision shows specific increases in contrast thresholds along tritan color-confusion lines. By the time the Hardy-Rand-Rittler and Farnsworth-Munsell 100-hue tests disclose abnormalities, gross defects in color contrast threshold can be seen with our system.
Esophageal Cancer Screening (PDQ®)—Patient Version
Esophageal cancer screening is not currently considered to be a routine part of cancer screening. Not all screening tests are helpful, and many have risks. Learn more about esophageal cancer risk factors and tests to detect it in this expert-reviewed summary.
Colorectal Cancer Screening (PDQ®)—Health Professional Version
Colorectal cancer (CRC) screening reduces CRC mortality; some screening modalities also reduce CRC incidence. Get detailed information about CRC screening tests (e.g., fecal occult blood test, sigmoidoscopy, colonoscopy, stool DNA) including potential benefits and harms in this clinician summary.
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... website . There is no standard or routine screening test for oral cavity, pharyngeal, and laryngeal cancer. No studies have shown that screening for oral cavity , pharyngeal , ...
[New guidelines in regard to cervical cancer screening].
Vargas-Hernández, Víctor Manuel; Acosta-Altamirano, Gustavo; Moreno-Eutimio, Mario Adán; Vargas-Aguilar, Víctor Manuel
2014-01-01
Cancer screening programs have been successful in reducing the incidence and mortality due to cervical cancer. For more than a decade, the human papillomavirus test has been recommended as part of these programs, however, Pap tests is not currently recommended for women 65 years of age who participated adequately in screening programs, continuing with these screening programs is not needed. Screening programs will be different in special populations at greatest risk where tests are frequently needed or use of alternative methods.
Lekhooa, Makhotso Rose; Walubo, Andrew; du Plessis, Jan B; Matsabisa, Motlalepula Gilbert
2017-07-12
Phela, is code name for a medicinal product made from four South African traditional medicinal plants (Clerodendrum glabrum E. Mey, Polianthes tuberosa (Linn.), Rotheca myricoides (Hochst.) Steane & Mabb. and Senna occidentalis (L.) Link). All these plants have established traditional use in a wide spectrum of diseases. Phela is under development for use as an immune booster in immunocompromised patients, which includes patients with the human immunodeficiency virus (HIV). Already several studies, both pre-clinical and clinical, have shown that Phela is a safe and effective immune booster. Despite some studies on the action of Phela, the mechanism of action by Phela is still not known. Understanding the mechanism of action will enable safer and effective use of the drug for the right indications. Unfortunately, there is no well characterized test-system for screening products for immune stimulant activity. Therefore, the objective of this study was to use Phela as the test article, to develop and validate a rat-model (test system) by which to screen medicines for immune stimulant activity. First, the batch of Phela used was authenticated by high performance liquid chromatography (HPLC) techniques; analytical methods for the immunosuppressant drugs, cyclosporine A (CsA), cyclophosphamide (CP) and dexamethasone (Dex) were developed and validated; and a slide-A-Lyzer dialysis was used to test for potential interactions in rat plasma of Phela with CsA, CP and Dex. Thereafter, using Sprague Dawley (SD) rats and in separate experiments, the effective dose of Phela in the study animals was determined in a dose ranging study with levamisole, a known immune stimulant as the positive control; the appropriate doses for immunosuppression by CsA, CP and Dex were determined; the time to reach 'established immunosuppression' with each drug was determined (it was also the time for intervention with Phela); and eventually, the effect of Phela on the immune system was tested separately for each drug induced immunosuppression. The immune system was monitored by observing for changes in plasma profiles of IL-2, IL-10, IgG, IgM, CD4 and CD8 cell counts at appropriate intervals, while in addition to function tests, the kidneys, liver, spleen, thymus, were weighed and examined for any pathology. The chromatographic fingerprint certified this batch of Phela as similar to the authentic Phela. There was no significant interaction between Phela and CsA, CP and Dex. The effective dose of Phela was determined to be 15.4mg/kg/day. Phela led to a moderate increase in the immune parameters in the normal rats. Co-administration of Phela 15mg/kg/day orally for 21 days with CsA led to stoppage and reversal of the immunosppressive effects of CsA that were exhibited as increased IL-2, IL-10, CD4 and CD8 counts, implying that Phela stimulates the cell mediate immunity (CMI). For CP, Phela led to stoppage and reversal, though moderate, of CP-induced suppression of IL-10, IgM and IgG only, implying that Phela stimulates the humoral immunity (HI) too. Phela had no effect on Dex induced immunosuppression. Stimulation of the CMI means that Phela clinical testing programme should focus on diseases or disorders that compromise the CMI, e.g., HIV and TB. The stimulation of the HI immunity means that Phela may stimulate existing memory cells to produce antibodies. The present study has revealed Phela's mechanism of action as mainly by stimulation of the CMI, implying that the use of Phela as immune booster in HIV patients is appropriate; and that using Phela as the test product, a rat model for screening medicinal products for immune stimulation has been successfully developed and validated, with a hope that it will lead to the testing of other related medicinal products. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Yanagawa, T; Tokudome, S
1990-01-01
We developed methods to assess the cancer risks by screening tests. These methods estimate the size of the high risk group adjusted for the characteristics of screening tests and estimate the incidence rates of cancer among the high risk group adjusted for the characteristics of the tests. A method was also developed for selecting the cut-off point of a screening test. Finally, the methods were applied to estimate the risk of the adult T-cell leukemia/lymphoma. PMID:2269244
Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda
2014-01-01
Objectives To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. Design and setting During May–July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15–24 years. Main outcome measures (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. Results 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450–4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17–67%. Conclusions Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together with rigorous evaluation, be implemented wherever dual tests are deployed. PMID:25324326
Levin, J Z; Fletcher, J C; Chen, X; Meyerowitz, E M
1998-06-01
In a screen to identify novel genes required for early Arabidopsis flower development, we isolated four independent mutations that enhance the Ufo phenotype toward the production of filamentous structures in place of flowers. The mutants fall into three complementation groups, which we have termed FUSED FLORAL ORGANS (FFO) loci. ffo mutants have specific defects in floral organ separation and/or positioning; thus, the FFO genes identify components of a boundary formation mechanism(s) acting between developing floral organ primordia. FFO1 and FFO3 have specific functions in cauline leaf/stem separation and in first- and third-whorl floral organ separation, with FFO3 likely acting to establish and FFO1 to maintain floral organ boundaries. FFO2 acts at early floral stages to regulate floral organ number and positioning and to control organ separation within and between whorls. Plants doubly mutant for two ffo alleles display additive phenotypes, indicating that the FFO genes may act in separate pathways. Plants doubly mutant for an ffo gene and for ufo, lfy, or clv3 reveal that the FFO genes play roles related to those of UFO and LFY in floral meristem initiation and that FFO2 and FFO3 may act to control cell proliferation late in inflorescence development.
Factors Accounting for a Missed Diagnosis of Cystic Fibrosis After Newborn Screening
Rock, Michael J.; Levy, Hara; Zaleski, Christina; Farrell, Philip M.
2015-01-01
Summary Newborn screening is a public health policy program involving the centralized testing laboratory, infant and their family, primary care provider, and subspecialist for confirmatory testing and follow-up of abnormal results. Cystic fibrosis (CF) newborn screening has now been enacted in all 50 states and the District of Columbia and throughout many countries in the world. Although CF neonatal screening will identify the vast majority of infants with CF, there are many factors in the newborn screening system that can lead to a missed diagnosis of CF. To inform clinicians, this article summarizes the CF newborn screening system and highlights 14 factors that can account for a missed diagnosis of CF. Care providers should maintain a high suspicion for CF if there are compatible symptoms, regardless of the results of the newborn screening test. These factors in newborn screening programs leading to a missed diagnosis of CF present opportunities for quality improvement in specimen collection, laboratory analysis of immunoreactive tryspinogen (IRT) and CF mutation testing, communication, and sweat testing. PMID:22081556
Watson, Verity; Ryan, Mandy; Watson, Emma
2009-06-01
To examine women's preferences for characteristics of chlamydia screening. Chlamydia trachomatis is the most common curable sexually transmitted disease. To design effective screening programs, it is important to fully capture the benefits of screening to patients. Thus, the value of experience factors must be considered alongside health outcomes. A self-complete discrete choice experiment questionnaire was administered to women attending a family planning clinic. Chlamydia screening was described by five characteristics: location of screening; type of screening test; cost of screening test; risk of developing pelvic inflammatory disease if chlamydia is untreated; and support provided when receiving results. One hundred twenty-six women completed the questionnaire. Respondents valued characteristics of the care experience. Screening was valued at 15 pound; less invasive screening tests increase willingness to pay by 7 pound, and more invasive tests reduce willingness to pay by 3.50 pound. The most preferred screening location was the family planning clinic, valued at 5 pound. The support of a trained health-care professional when receiving results was valued at 4 pound. Respondents under 25 years and those in a casual relationship were less likely to be screened. Women valued experience factors in the provision of chlamydia screening. To correctly value these screening programs and to predict uptake, cost-effectiveness studies should take such values into account. Failure to do this may result in incorrect policy recommendations.
Wrighton-Smith, Peter; Sneed, Laurie; Humphrey, Frances; Tao, Xuguang; Bernacki, Edward
2012-07-01
To determine the price point at which an interferon-γ release assay (IGRA) is less costly than a tuberculin skin test (TST) for health care employee tuberculosis screening. A multidecision tree-based cost model incorporating inputs gathered from time-motion studies and parallel testing by IGRA and TST was conducted in a subset of our employees. Administering a TST testing program costs $73.20 per person screened, $90.80 per new hire, and $63.42 per annual screen. Use of an IGRA for employee health testing is cost saving at an IGRA test cost of $54.83 or less per test and resulted in higher completion rates because of the elimination of the need for a second visit to interpret the TST. Using an IGRA for employee health screening can be an institutional cost saving and results in higher compliance rates.
2007-01-01
Purpose Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. Methods Over 3 years, 4040 preschool children were screened in the Vision in Preschoolers (VIP) Study, with different screening tests administered each year. Examinations were performed to identify children with strabismus. The best screening tests for detecting children with any targeted condition were noncycloplegic retinoscopy (NCR), Retinomax autorefractor (Right Manufacturing, Virginia Beach, VA), SureSight Vision Screener (Welch-Allyn, Inc., Skaneateles, NY), and Lea Symbols (Precision Vision, LaSalle, IL and Good-Lite Co., Elgin, IL) and HOTV optotypes VA tests. Analyses were conducted with these tests of refractive error or VA paired with the best tests for detecting strabismus (unilateral cover testing, Random Dot “E” [RDE] and Stereo Smile Test II [Stereo Optical, Inc., Chicago, IL]; and MTI PhotoScreener [PhotoScreener, Inc., Palm Beach, FL]). The change in sensitivity that resulted from combining a test of eye alignment with a test of refractive error or VA was determined with specificity set at 90% and 94%. Results Among the 4040 children, 157 were identified as having strabismus. For screening tests conducted by eye care professionals, the addition of a unilateral cover test to a test of refraction generally resulted in a statistically significant increase (range, 15%–25%) in detection of strabismus. For screening tests administered by trained lay screeners, the addition of Stereo Smile II to SureSight resulted in a statistically significant increase (21%) in sensitivity for detection of strabismus. Conclusions The most efficient and low-cost ways to achieve a statistically significant increase in sensitivity for detection of strabismus were by combining the unilateral cover test with the autorefractor (Retinomax) administered by eye care professionals and by combining Stereo Smile II with SureSight administered by trained lay screeners. The decision of whether to include a test of alignment should be based on the screening program’s goals (e.g., targeted visual conditions) and resources. PMID:17591881
Wang, Ying; Latypov, Ramil F; Lomakin, Aleksey; Meyer, Julie A; Kerwin, Bruce A; Vunnum, Suresh; Benedek, George B
2014-05-05
Colloidal stability of antibody solutions, i.e., the propensity of the folded protein to precipitate, is an important consideration in formulation development of therapeutic monoclonal antibodies. In a protein solution, different pathways including crystallization, colloidal aggregation, and liquid-liquid phase separation (LLPS) can lead to the formation of precipitates. The kinetics of crystallization and aggregation are often slow and vary from protein to protein. Due to the diverse mechanisms of these protein condensation processes, it is a challenge to develop a standardized test for an early evaluation of the colloidal stability of antibody solutions. LLPS would normally occur in antibody solutions at sufficiently low temperature, provided that it is not preempted by freezing of the solution. Poly(ethylene glycol) (PEG) can be used to induce LLPS at temperatures above the freezing point. Here, we propose a colloidal stability test based on inducing LLPS in antibody solutions and measuring the antibody concentration of the dilute phase. We demonstrate experimentally that such a PEG-induced LLPS test can be used to compare colloidal stability of different antibodies in different solution conditions and can be readily applied to high-throughput screening. We have derived an equation for the effects of PEG concentration and molecular weight on the results of the LLPS test. Finally, this equation defines a binding energy in the condensed phase, which can be determined in the PEG-induced LLPS test. This binding energy is a measure of attractive interactions between antibody molecules and can be used for quantitative characterization of the colloidal stability of antibody solutions.
Colorectal cancer screening: An updated review of the available options.
Issa, Iyad A; Noureddine, Malak
2017-07-28
Colorectal cancer (CRC) is a significant cause of morbidity and mortality worldwide. However, colon cancer incidence and mortality is declining over the past decade owing to adoption of effective screening programs. Nevertheless, in some parts of the world, CRC incidence and mortality remain on the rise, likely due to factors including "westernized" diet, lifestyle, and lack of health-care infrastructure and resources. Participation and adherence to different national screening programs remain obstacles limiting the achievement of screening goals. Different modalities are available ranging from stool based tests to radiology and endoscopy with varying sensitivity and specificity. However, the availability of these tests is limited to areas with high economic resources. Recently, FDA approved a blood-based test (Epi procolon ® ) for CRC screening. This blood based test may serve to increase the participation and adherence rates. Hence, leading to increase in colon cancer detection and prevention. This article will discuss various CRC screening tests with a particular focus on the data regarding the new approved blood test. Finally, we will propose an algorithm for a simple cost-effective CRC screening program.
Colorectal cancer screening: An updated review of the available options
Issa, Iyad A; Noureddine, Malak
2017-01-01
Colorectal cancer (CRC) is a significant cause of morbidity and mortality worldwide. However, colon cancer incidence and mortality is declining over the past decade owing to adoption of effective screening programs. Nevertheless, in some parts of the world, CRC incidence and mortality remain on the rise, likely due to factors including “westernized” diet, lifestyle, and lack of health-care infrastructure and resources. Participation and adherence to different national screening programs remain obstacles limiting the achievement of screening goals. Different modalities are available ranging from stool based tests to radiology and endoscopy with varying sensitivity and specificity. However, the availability of these tests is limited to areas with high economic resources. Recently, FDA approved a blood-based test (Epi procolon®) for CRC screening. This blood based test may serve to increase the participation and adherence rates. Hence, leading to increase in colon cancer detection and prevention. This article will discuss various CRC screening tests with a particular focus on the data regarding the new approved blood test. Finally, we will propose an algorithm for a simple cost-effective CRC screening program. PMID:28811705
Fowler, T; Edeghere, O; Inglis, N; Bradshaw, S
2013-03-01
Advances in technology have raised the possibility of including gonorrhoea testing as part of chlamydia screening. In England this is recommended only where the positive predictive value (PPV) of the test is ≥90%. This study assessed the PPV for gonorrhoea testing using routine testing data. Routine data (including gonorrhoea testing) from the Greater Manchester Chlamydia Screening Programme (GMCSP) in 2009/2010, were used to estimate the PPV for gonorrhoea testing. Of those screened, 0.3% (59/18044) of men and 0.4% (174/41873) of women tested positive for gonorrhoea. The PPV was 82.3% in women and 73.6% in men, in those who also tested positive for chlamydia. For women and men testing negative for chlamydia the PPV for a positive gonorrhoea test was incalculable. The low PPV observed in most groups suggests that where population testing for gonorrhoea occurs there is a need for further confirmatory testing of positive results before treatment decisions are made. Clinicians should be aware of screening test result limitations in this context.
The cost-effectiveness of screening for colorectal cancer.
Telford, Jennifer J; Levy, Adrian R; Sambrook, Jennifer C; Zou, Denise; Enns, Robert A
2010-09-07
Published decision analyses show that screening for colorectal cancer is cost-effective. However, because of the number of tests available, the optimal screening strategy in Canada is unknown. We estimated the incremental cost-effectiveness of 10 strategies for colorectal cancer screening, as well as no screening, incorporating quality of life, noncompliance and data on the costs and benefits of chemotherapy. We used a probabilistic Markov model to estimate the costs and quality-adjusted life expectancy of 50-year-old average-risk Canadians without screening and with screening by each test. We populated the model with data from the published literature. We calculated costs from the perspective of a third-party payer, with inflation to 2007 Canadian dollars. Of the 10 strategies considered, we focused on three tests currently being used for population screening in some Canadian provinces: low-sensitivity guaiac fecal occult blood test, performed annually; fecal immunochemical test, performed annually; and colonoscopy, performed every 10 years. These strategies reduced the incidence of colorectal cancer by 44%, 65% and 81%, and mortality by 55%, 74% and 83%, respectively, compared with no screening. These strategies generated incremental cost-effectiveness ratios of $9159, $611 and $6133 per quality-adjusted life year, respectively. The findings were robust to probabilistic sensitivity analysis. Colonoscopy every 10 years yielded the greatest net health benefit. Screening for colorectal cancer is cost-effective over conventional levels of willingness to pay. Annual high-sensitivity fecal occult blood testing, such as a fecal immunochemical test, or colonoscopy every 10 years offer the best value for the money in Canada.
Who attends a UK diabetes screening programme? Findings from the ADDITION-Cambridge study.
Sargeant, L A; Simmons, R K; Barling, R S; Butler, R; Williams, K M; Prevost, A T; Kinmonth, A L; Wareham, N J; Griffin, S J
2010-09-01
One of the factors influencing the cost-effectiveness of population screening for Type 2 diabetes may be uptake. We examined attendance and practice- and individual-level factors influencing uptake at each stage of a diabetes screening programme in general practice. A stepwise screening programme was undertaken among 135, 825 people aged 40-69 years without known diabetes in 49 general practices in East England. The programme included a score based on routinely available data (age, sex, body mass index and prescribed medication) to identify those at high risk, who were offered random capillary blood glucose (RBG) and glycosylated haemoglobin tests. Those screening positive were offered fasting capillary blood glucose (FBG) and confirmatory oral glucose tolerance tests (OGTT). There were 33 539 high-risk individuals invited for a RBG screening test; 24 654 (74%) attended. Ninety-four per cent attended the follow-up FBG test and 82% the diagnostic OGTT. Seventy per cent of individuals completed the screening programme. Practices with higher general practitioner staff complements and those located in more deprived areas had lower uptake for RBG and FBG tests. Male sex and a higher body mass index were associated with lower attendance for RBG testing. Older age, prescription of antihypertensive medication and a higher risk score were associated with higher attendance for FBG and RBG tests. High attendance rates can be achieved by targeted stepwise screening of individuals assessed as high risk by data routinely available in general practice. Different strategies may be required to increase initial attendance, ensure completion of the screening programme, and reduce the risk that screening increases health inequalities.
Screening options for Down syndrome: how women choose in real clinical setting.
Lo, T K; Lai, F K; Leung, W C; Lau, W L; Ng, L S; Wong, W C; Tam, S S; Yee, Y C; Choi, H; Lam, H S W; Sham, A S Y; Tang, L C H; Chin, R K H
2009-09-01
To study pregnant women's preference among various screening options for Down syndrome (DS) in routine clinical setting, and its potential association with women's demographic characteristics. Women aged 35 years and older carrying singleton pregnancy were offered a variety of screening tests for DS before 14 weeks of gestation. Their preference was confirmed by the test they actually underwent. The association between women's choice of test and a number of demographic characteristics was studied using multinomial regression. Among 1967 eligible women, 619 opted for first-trimester screening test (FTS), 924 for partial integrated test (PIT), and 424 for full integrated test (FIT). Nulliparous women and working mothers were more likely to choose FTS and FIT. Women with history of subfertility were more likely to choose FIT. Women with family history of chromosomal abnormalities were more likely to choose FTS. The choice of screening test could be predicted for 49.9% of women using four demographic characteristics. Among older women of predominantly Chinese ethnicity, integrated test is a favorite alternative to FTS. Their choice of DS screening test can be predicted by their obstetric and socioeconomic characteristics. Many women show willingness to pay for a test with a lower false-positive rate.
10 CFR 26.131 - Cutoff levels for validity screening and initial validity tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Cutoff levels for validity screening and initial validity tests. 26.131 Section 26.131 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.131 Cutoff levels for validity screening and initial validity tests. (a) Each...
10 CFR 26.131 - Cutoff levels for validity screening and initial validity tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Cutoff levels for validity screening and initial validity tests. 26.131 Section 26.131 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.131 Cutoff levels for validity screening and initial validity tests. (a) Each...
Cross-Validation of the Computerized Adaptive Screening Test (CAST).
ERIC Educational Resources Information Center
Pliske, Rebecca M.; And Others
The Computerized Adaptive Screening Test (CAST) was developed to provide an estimate at recruiting stations of prospects' Armed Forces Qualification Test (AFQT) scores. The CAST was designed to replace the paper-and-pencil Enlistment Screening Test (EST). The initial validation study of CAST indicated that CAST predicts AFQT at least as accurately…
Impact of single particle oscillations on screening of a test charge
NASA Astrophysics Data System (ADS)
Ramazanov, Tlekkabul S.; Moldabekov, Zhandos A.; Gabdullin, Maratbek T.
2018-06-01
Screening of a test charge by electrons oscillating in an external alternating electrical (laser) field is analyzed. It is shown that single particle oscillations lead to the creation of an oscillatory pattern of the test charge's potential at large distances. Analysis has been done by considering and neglecting the contribution of ions on the screening. Impact of the quantum diffraction (non-locality) and of the collisional damping on the test charge's potential is considered. It is shown that electrons are unable to provide screening of the test charge if the frequency of the induced single particle oscillations larger than the electron-plasma frequency. In the opposite case of low frequencies, the potential of the test charge changes its sign if the screening by ions is neglected.
Liver (Hepatocellular) Cancer Screening (PDQ®)—Patient Version
Liver (hepatocellular) cancer screening is not currently recommended as a routine part of cancer screening. Not all screening tests are helpful, and many have risks. Learn more about liver cancer and the tests used to detect it in this expert-reviewed summary.
Added value of second biopsy target in screen-detected widespread suspicious breast calcifications.
Falkner, Nathalie M; Hince, Dana; Porter, Gareth; Dessauvagie, Ben; Jeganathan, Sanjay; Bulsara, Max; Lo, Glen
2018-06-01
There is controversy on the optimal work-up of screen-detected widespread breast calcifications: whether to biopsy a single target or multiple targets. This study evaluates agreement between multiple biopsy targets within the same screen-detected widespread (≥25 mm) breast calcification to determine if the second biopsy adds value. Retrospective observational study of women screened in a statewide general population risk breast cancer mammographic screening program from 2009 to 2016. Screening episodes recalled for widespread calcifications where further views indicated biopsy, and two or more separate target areas were sampled within the same lesion were included. Percentage agreement and Cohen's Kappa were calculated. A total of 293317 women were screened during 761124 separate episodes with recalls for widespread calcifications in 2355 episodes. In 171 women, a second target was biopsied within the same lesion. In 149 (86%) cases, the second target biopsy result agreed with the first biopsy (κ = 0.6768). Agreement increased with increasing mammography score (85%, 86% and 92% for score 3, 4 and 5 lesions). Same day multiple biopsied lesions were three times more likely to yield concordant results compared to post-hoc second target biopsy cases. While a single target biopsy is sufficient to discriminate a benign vs. malignant diagnosis in most cases, in 14% there is added value in performing a second target biopsy. Biopsies performed prospectively are more likely to yield concordant results compared to post-hoc second target biopsy cases, suggesting a single prospective biopsy may be sufficient when results are radiological-pathological concordant; discordance still requires repeat sampling. © 2018 The Royal Australian and New Zealand College of Radiologists.
An experience of qualified preventive screening: shiraz smart screening software.
Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza
2015-01-01
Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.
Mansouri, David; McMillan, Donald C; Grant, Yasmin; Crighton, Emilia M; Horgan, Paul G
2013-01-01
Population-based colorectal cancer screening has been shown to reduce cancer specific mortality and is used across the UK. Despite evidence that older age, male sex and deprivation are associated with an increased incidence of colorectal cancer, uptake of bowel cancer screening varies across demographic groups. The aim of this study was to assess the impact of age, sex and deprivation on outcomes throughout the screening process. A prospectively maintained database, encompassing the first screening round of a faecal occult blood test screening programme in a single geographical area, was analysed. Overall, 395,096 individuals were invited to screening, 204,139 (52%) participated and 6079 (3%) tested positive. Of the positive tests, 4625 (76%) attended for colonoscopy and cancer was detected in 396 individuals (9%). Lower uptake of screening was associated with younger age, male sex and deprivation (all p<0.001). Only deprivation was associated with failure to proceed to colonoscopy following a positive test (p<0.001). Despite higher positivity rates in those that were more deprived (p<0.001), the likelihood of detecting cancer in those attending for colonoscopy was lower (8% most deprived vs 10% least deprived, p = 0.003). Individuals who are deprived are less likely to participate in screening, less likely to undergo colonoscopy and less likely to have cancer identified as a result of a positive test. Therefore, this study suggests that strategies aimed at improving participation of deprived individuals in colorectal cancer screening should be directed at all stages of the screening process and not just uptake of the test.
Blom, Johannes; Törnberg, Sven
2017-09-01
Objective To evaluate interval cancers in the population-based colorectal cancer screening programme of Stockholm/Gotland, Sweden. Methods From 2008, individuals aged 60-69 were invited to colorectal cancer screening using biennial guaiac-based faecal occult blood test (Hemoccult®). Interval cancers, defined as colorectal cancer among participants not diagnosed by the screening programme but registered in the Swedish cancer register, were evaluated by cross-checking the screening histories for all cancers in the region 2008-2012. Results Of 203,848 individuals from nine different birth cohorts who participated (∼60%), 4530 (2.2%) tested positive. All invited individuals were followed up for 24 months after invitation. The cancer register reported 557 colorectal cancer, 219 (39.3%) screen-detected cancers and 338 (60.7%) interval cancers, generating both test- and episode sensitivities of approximately 40% and an interval cancer-rate of 17.1/10,000 tests. Among individuals with positive tests without colorectal cancer diagnosed at work-up colonoscopy, 37 interval cancers (10.9%) occurred. There was statistically significant lower sensitivity in women, ranging 22.4-32.2%, compared with 43.2-52.0% in men. Age-group and tumour location were not strongly correlated to screen-detected cancer rates. The programme sensitivity increased by year (20.3-25.0%), with successively more colorectal cancers diagnosed within the expanding programme (11.6-16.2%). Conclusion Interval cancer is a quality indicator of a screening programme. As the interval cancer-rate determined in a well-organized population-based screening programme was actually higher than the screen-detected cancer rate, a change to a more sensitive screening test is indicated. The lower screen-detected cancers among women, and compliance and quality of work-up colonoscopies also need attention.
Jung, Jae Hwan; Kim, Gha-Young; Seo, Tae Seok
2011-10-21
Here we report an integrated microdevice consisting of an efficient passive mixer, a magnetic separation chamber, and a capillary electrophoretic microchannel in which DNA barcode assay, target pathogen separation, and barcode DNA capillary electrophoretic analysis were performed sequentially within 30 min for multiplex pathogen detection at the single-cell level. The intestine-shaped serpentine 3D micromixer provides a high mixing rate to generate magnetic particle-pathogenic bacteria-DNA barcode labelled AuNP complexes quantitatively. After magnetic separation and purification of those complexes, the barcode DNA strands were released and analyzed by the microfluidic capillary electrophoresis within 5 min. The size of the barcode DNA strand was controlled depending on the target bacteria (Staphylococcus aureus, Escherichia coli O157:H7, and Salmonella typhimurium), and the different elution time of the barcode DNA peak in the electropherogram allows us to recognize the target pathogen with ease in the monoplex as well as in the multiplex analysis. In addition, the quantity of the DNA barcode strand (∼10(4)) per AuNP is enough to be observed in the laser-induced confocal fluorescence detector, thereby making single-cell analysis possible. This novel integrated microdevice enables us to perform rapid, sensitive, and multiplex pathogen detection with sample-in-answer-out capability to be applied for biosafety testing, environmental screening, and clinical trials.
... Analgesics - screen; Antidepressants - screen; Narcotics - screen; Phenothiazines - screen; Drug abuse screen; Blood alcohol test ... poisoning) Complicated alcohol abstinence (delirium tremens) Delirium ... Fetal alcohol syndrome Intentional overdose Seizures Stroke ...
Zhao, Chengquan
2015-01-01
Screening for cervical cancer with cytology testing has been very effective in reducing cervical cancer in the United States. For decades, the approach was an annual Pap test. In 2000, the Hybrid Capture 2 human papillomavirus (HPV) test was approved by the U.S. Food and Drug Administration (FDA) for screening women who have atypical squamous cells of underdetermined significance (ASCUS) detected by Pap test to determine the need for colposcopy. In 2003, the FDA approved expanding the use of the test to include screening performed in conjunction with a Pap test for women over the age of 30 years, referred to as “cotesting.” Cotesting allows women to extend the testing interval to 3 years if both tests have negative results. In April of 2014, the FDA approved the use of an HPV test (the cobas HPV test) for primary cervical cancer screening for women over the age of 25 years, without the need for a concomitant Pap test. The approval recommended either colposcopy or a Pap test for patients with specific high-risk HPV types detected by the HPV test. This was based on the results of the ATHENA trial, which included more than 40,000 women. Reaction to this decision has been mixed. Supporters point to the fact that the primary-screening algorithm found more disease (cervical intraepithelial neoplasia 3 or worse [CIN3+]) and also found it earlier than did cytology or cotesting. Moreover, the positive predictive value and positive-likelihood ratio of the primary-screening algorithm were higher than those of cytology. Opponents of the decision prefer cotesting, as this approach detects more disease than the HPV test alone. In addition, the performance of this new algorithm has not been assessed in routine clinical use. Professional organizations will need to develop guidelines that incorporate this testing algorithm. In this Point-Counterpoint, Dr. Stoler explains why he favors the primary-screening algorithm, while Drs. Austin and Zhao explain why they prefer the cotesting approach to screening for cervical cancer. PMID:25948606
Ata, Ashar; Elzey, Jared D; Insaf, Tabassum Z; Grau, Ana M; Stain, Steven C; Ahmed, Nasar U
2006-01-01
Studies exploring CRC testing prevalence and correlates within US populations have provided limited and sometimes conflicting information. The most recent national-level reports have described US usage of CRC tests but none have considered only those tests done specifically for screening reasons as an outcome variable. Using the NHIS 2000 sample of >or=50 year-old, we assessed screening behavior using an outcome variable accounting for (1) any combination of recommended tests (2) done within their respective time guidelines, and (3) specifically for screening purposes. Only 25.8% (95% CI: 24.9-26.7%) of the population reported getting a test done for screening purposes within the recommended time. Most (>85%) of the FOBTs and only about 60% of endoscopies were done for screening. Among those who had an endoscopy within the recommended time, Blacks were more likely than Whites to report screening as the purpose of the test. Hispanics had the lowest test usage irrespective of test time, reason or type. Hispanics were 50% (p<0.001) less likely to be adherent, and Blacks approximately 22% (p<0.01) less likely to be adherent, than Whites. After multivariate adjustment, differences between Whites and Blacks disappeared; Hispanics remained less likely. Increasing education predicted higher adherence among Whites but only undergraduate completion did so among Blacks. Male gender predicted adherence only among Blacks and insurance only among Hispanics. Preventive screening for CRC is lower than estimates from previous studies. Future studies should consider accounting for test purpose. Our findings need confirmation through studies based on objective data.
Wang, Li-Yun; Chen, Nien-I; Chen, Pin-Wen; Chiang, Shu-Chuan; Hwu, Wuh-Liang; Lee, Ni-Chung; Chien, Yin-Hsiu
2013-02-10
Tandem mass spectrometry (MS/MS) analysis is a powerful tool for newborn screening, and many rare inborn errors of metabolism are currently screened using MS/MS. However, the sensitivity of MS/MS screening for several inborn errors, including citrin deficiency (screened by citrulline level) and carnitine uptake defect (CUD, screened by free carnitine level), is not satisfactory. This study was conducted to determine whether a second-tier molecular test could improve the sensitivity of citrin deficiency and CUD detection without increasing the false-positive rate. Three mutations in the SLC25A13 gene (for citrin deficiency) and one mutation in the SLC22A5 gene (for CUD) were analyzed in newborns who demonstrated an inconclusive primary screening result (with levels between the screening and diagnostic cutoffs). The results revealed that 314 of 46 699 newborns received a second-tier test for citrin deficiency, and two patients were identified; 206 of 30 237 newborns received a second-tier testing for CUD, and one patient was identified. No patients were identified using the diagnostic cutoffs. Although the incidences for citrin deficiency (1:23 350) and CUD (1:30 000) detected by screening are still lower than the incidences calculated from the mutation carrier rates, the second-tier molecular test increases the sensitivity of newborn screening for citrin deficiency and CUD without increasing the false-positive rate. Utilizing a molecular second-tier test for citrin deficiency and carnitine transporter deficiency is feasible.
Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening
Li, Jun; Zhao, Guixiang; Hall, Ingrid J.
2015-01-01
Introduction For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Methods Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. Results The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (p<0.001). In addition, men who had only discussed the disadvantages of PSA testing with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Conclusions Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients’ values and preferences in decisions about PSA testing. PMID:25997905
Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening.
Li, Jun; Zhao, Guixiang; Hall, Ingrid J
2015-08-01
For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (p<0.001). In addition, men who had only discussed the disadvantages of PSA testing with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients' values and preferences in decisions about PSA testing. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Wu, Te-Kao (Inventor)
1996-01-01
The design and performance of a wide angle, single screen, frequency selective surface (FSS) with gridded square-loop path elements are described for diplexing closely separated signal bands, for example, X- and Ku-band signals in an Orbiting Very Long Baseline Interferometer (OVLBI) earth station reflector antenna system, as well as other applications such as military and commercial communications via satellites. Excellent agreement is obtained between the predicted and measured results of this FSS design using the gridded square-loop patch elements sandwiched between 0.0889 cm thick tetrafluoroethylene fluorocarbon polymer (PTFE) slabs. Resonant frequency drift is reduced by 1 GHz with an incidence angle from 0 deg normal to 40 deg from normal.
An efficient early phase 2 procedure to screen medications for efficacy in smoking cessation.
Perkins, Kenneth A; Lerman, Caryn
2014-01-01
Initial screening of new medications for potential efficacy (i.e., Food and Drug Administration (FDA) early phase 2), such as in aiding smoking cessation, should be efficient in identifying which drugs do, or do not, warrant more extensive (and expensive) clinical testing. This focused review outlines our research on development, evaluation, and validation of an efficient crossover procedure for sensitivity in detecting medication efficacy for smoking cessation. First-line FDA-approved medications of nicotine patch, varenicline, and bupropion were tested as model drugs, in three separate placebo-controlled studies. We also tested specificity of our procedure in identifying a drug that lacks efficacy, using modafinil. This crossover procedure showed sensitivity (increased days of abstinence) during week-long "practice" quit attempts with each of the active cessation medications (positive controls) versus placebo, but not with modafinil (negative control) versus placebo, as hypothesized. Sensitivity to medication efficacy signal was observed only in smokers high in intrinsic quit motivation (i.e., already preparing to quit soon) and not smokers low in intrinsic quit motivation, even if monetarily reinforced for abstinence (i.e., given extrinsic motivation). A crossover procedure requiring less time and fewer subjects than formal trials may provide an efficient strategy for a go/no-go decision whether to advance to subsequent phase 2 randomized clinical trials with a novel drug. Future research is needed to replicate our results and evaluate this procedure with novel compounds, identify factors that may limit its utility, and evaluate its applicability to testing efficacy of compounds for treating other forms of addiction.
Comparison of Breast Density Between Synthesized Versus Standard Digital Mammography.
Haider, Irfanullah; Morgan, Matthew; McGow, Anna; Stein, Matthew; Rezvani, Maryam; Freer, Phoebe; Hu, Nan; Fajardo, Laurie; Winkler, Nicole
2018-06-12
To evaluate perceptual difference in breast density classification using synthesized mammography (SM) compared with standard or full-field digital mammography (FFDM) for screening. This institutional review board-approved, retrospective, multireader study evaluated breast density on 200 patients who underwent baseline screening mammogram during which both SM and FFDM were obtained contemporaneously from June 1, 2016, through November 30, 2016. Qualitative breast density was independently assigned by seven readers initially evaluating FFDM alone. Then, in a separate session, these same readers assigned breast density using synthetic views alone on the same 200 patients. The readers were again blinded to each other's assignment. Qualitative density assessment was based on BI-RADS fifth edition. Interreader agreement was evaluated with κ statistic using 95% confidence intervals. Testing for homogeneity in paired proportions was performed using McNemar's test with a level of significance of .05. For patients across the SM and standard 2-D data set, diagnostic testing with McNemar's test with P = 0.32 demonstrates that the minimal density transitions across FFDM and SM are not statistically significant density shifts. Taking clinical significance into account, only 8 of 200 (4%) patients had clinically significant transition (dense versus not dense). There was substantial interreader agreement with overall κ in FFDM of 0.71 (minimum 0.53, maximum 0.81) and overall SM κ average of 0.63 (minimum 0.56, maximum 0.87). Overall subjective breast density assignment by radiologists on SM is similar to density assignment on standard 2-D mammogram. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Modeling Amorphous Microporous Polymers for CO2 Capture and Separations.
Kupgan, Grit; Abbott, Lauren J; Hart, Kyle E; Colina, Coray M
2018-06-13
This review concentrates on the advances of atomistic molecular simulations to design and evaluate amorphous microporous polymeric materials for CO 2 capture and separations. A description of atomistic molecular simulations is provided, including simulation techniques, structural generation approaches, relaxation and equilibration methodologies, and considerations needed for validation of simulated samples. The review provides general guidelines and a comprehensive update of the recent literature (since 2007) to promote the acceleration of the discovery and screening of amorphous microporous polymers for CO 2 capture and separation processes.
Mikaeli, S; Thorsén, G; Karlberg, B
2001-01-12
A novel approach to multivariate evaluation of separation electrolytes for micellar electrokinetic chromatography is presented. An initial screening of the experimental parameters is performed using a Plackett-Burman design. Significant parameters are further evaluated using full factorial designs. The total resolution of the separation is calculated and used as response. The proposed scheme has been applied to the optimisation of the separation of phenols and the chiral separation of (+)-1-(9-anthryl)-2-propyl chloroformate-derivatized amino acids. A total of eight experimental parameters were evaluated and optimal conditions found in less than 48 experiments.
Malila, Nea; Oivanen, Tiina; Malminiemi, Outi; Hakama, Matti
2008-11-20
To report the sensitivities of the faecal occult blood test, screening episode, and screening programme for colorectal cancer and the benefits of applying a randomised design at the implementation phase of a new public health policy. Experimental design incorporated in public health evaluation using randomisation at individual level in the target population. 161 of the 431 Finnish municipalities in 2004-6. 106 000 adults randomised to screening or control arms. In total, 52 998 adults aged 60-64 in the screening arm received faecal occult blood test kits. Test, episode, and programme sensitivities estimated by the incidence method and corrected for selective attendance and overdiagnosis. The response for screening was high overall (70.8%), and significantly better in women (78.1%) than in men (63.3%). The incidence of cancer in the controls was somewhat higher in men than in women (103 v 93 per 100 000 person years), which was not true for interval cancers (42 v 49 per 100 000 person years). The sensitivity of the faecal occult blood test was 54.6%. Only a few interval cancers were detected among those with positive test results, hence the episode sensitivity of 51.3% was close to the test sensitivity. At the population level the sensitivity of the programme was 37.5%. Although relatively low, the sensitivity of screening for colorectal cancer with the faecal occult blood test in Finland was adequate. An experimental design is a prerequisite for evaluation of such a screening programme because the effectiveness of preventing deaths is likely to be small and results may otherwise remain inconclusive. Thus, screening for colorectal cancer using any primary test modality should be launched in a public health programme with randomisation of the target population at the implementation phase.
Fernandes, Kimberly A; Sutradhar, Rinku; Borkhoff, Cornelia M; Baxter, Nancy; Lofters, Aisha; Rabeneck, Linda; Tinmouth, Jill; Paszat, Lawrence
2015-01-01
Screening for cervical, breast and colon cancers, and elevations of cholesterol and glucose, reduces premature cause-specific mortality from these cancers and circulatory diseases. Despite primary care reforms and incentives, and promotion of cancer-screening programs among individuals, participation is suboptimal. We aimed to examine participation as of Dec. 31, 2011, by factors of deprivation, demographics and primary care at the small-area level. From health care administrative databases, we identified people eligible for each screening test, and their participation, in each dissemination area (referred to as small areas, n = 18 950) in Ontario. We calculated rates for each test among small areas (overall and stratified by demographic, socioeconomic and primary care descriptors) and stratified by sex for all tests combined. We loaded all data into a geographic information system. Funnel plots were generated showing the percentage of eligible people who completed screening for all tests by small area, stratified by sex. Overall and stratified screening prevalence ratios were calculated among small areas. Among small areas, the mean and SD for participation in all tests combined was 31.6% (SD 11.0%) for women and 41.2% (SD 12.0%) for men. Screening prevalence among small areas, for each test and for all tests combined, overall and stratified by sex, declined with decreasing percentage with high school completion, decreasing socioeconomic quintile, and decreasing percentage with an identifiable primary care physician. Our results show that the rate of participation in all eligible screening tests among small areas is much lower than the rate of participation in any one particular test. This finding has implications for the design and implementation of strategies to improve rates of screening.
Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.
Doyle, Kelly; Strathmann, Frederick G
2017-02-01
This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.
Anti-nuclear antibody screening using HEp-2 cells.
Buchner, Carol; Bryant, Cassandra; Eslami, Anna; Lakos, Gabriella
2014-06-23
The American College of Rheumatology position statement on ANA testing stipulates the use of IIF as the gold standard method for ANA screening(1). Although IIF is an excellent screening test in expert hands, the technical difficulties of processing and reading IIF slides--such as the labor intensive slide processing, manual reading, the need for experienced, trained technologists and the use of dark room--make the IIF method difficult to fit in the workflow of modern, automated laboratories. The first and crucial step towards high quality ANA screening is careful slide processing. This procedure is labor intensive, and requires full understanding of the process, as well as attention to details and experience. Slide reading is performed by fluorescent microscopy in dark rooms, and is done by trained technologists who are familiar with the various patterns, in the context of cell cycle and the morphology of interphase and dividing cells. Provided that IIF is the first line screening tool for SARD, understanding the steps to correctly perform this technique is critical. Recently, digital imaging systems have been developed for the automated reading of IIF slides. These systems, such as the NOVA View Automated Fluorescent Microscope, are designed to streamline the routine IIF workflow. NOVA View acquires and stores high resolution digital images of the wells, thereby separating image acquisition from interpretation; images are viewed an interpreted on high resolution computer monitors. It stores images for future reference and supports the operator's interpretation by providing fluorescent light intensity data on the images. It also preliminarily categorizes results as positive or negative, and provides pattern recognition for positive samples. In summary, it eliminates the need for darkroom, and automates and streamlines the IIF reading/interpretation workflow. Most importantly, it increases consistency between readers and readings. Moreover, with the use of barcoded slides, transcription errors are eliminated by providing sample traceability and positive patient identification. This results in increased patient data integrity and safety. The overall goal of this video is to demonstrate the IIF procedure, including slide processing, identification of common IIF patterns, and the introduction of new advancements to simplify and harmonize this technique.
Consensus Document on Prevention and Treatment of Tuberculosis in Patients for Biological Treatment.
Mir Viladrich, Isabel; Daudén Tello, Esteban; Solano-López, Guillermo; López Longo, Francisco Javier; Taxonera Samso, Carlos; Sánchez Martínez, Paquita; Martínez Lacasa, Xavier; García Gasalla, Mercedes; Dorca Sargatal, Jordi; Arias-Guillén, Miguel; García García, José Maria
2016-01-01
Tuberculosis risk is increased in patients with chronic inflammatory diseases receiving any immunosuppressive treatment, notably tumor necrosis factor (TNF) antagonists therapy. Screening for the presence of latent infection with Mycobacterium tuberculosis and targeted preventive treatment to reduce the risk of progression to TB is mandatory in these patients. This Consensus Document summarizes the current knowledge and expert opinion of biologic therapies including TNF-blocking treatments. It provides recommendations for the use of interferon-gamma release assays (IGRA) and tuberculin skin test (TST) for the diagnosis of latent tuberculosis infection in these patients, and for the type and duration of preventive therapy. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.
Green, Beverly B; Wang, C Y; Horner, Kathryn; Catz, Sheryl; Meenan, Richard T; Vernon, Sally W; Carrell, David; Chubak, Jessica; Ko, Cynthia; Laing, Sharon; Bogart, Andy
2010-11-01
Screening decreases colorectal cancer (CRC) morbidity and mortality, yet remains underutilized. Screening breakdowns arise from lack of uptake and failure to follow-up after a positive screening test. Systems of support to increase colorectal cancer screening and follow-up (SOS) is a randomized trial designed to increase: (1) CRC screening and (2) follow-up of positive screening tests. The Chronic Care Model and the Preventive Health Model inform study design. The setting is a large nonprofit healthcare organization. In part-1 study, patients age 50-75 due for CRC screening are randomized to one of 4 study conditions. Arm 1 receives usual care. Arm 2 receives automated support (mailed information about screening choices and fecal occult blood tests (FOBT)). Arm 3 receives automated and assisted support (a medical assistant telephone call). Arm 4 receives automated, assisted, and care management support (a registered nurse provides behavioral activation and coordination of care). In part-2, study patients with a positive FOBT or adenomas on flexible sigmoidoscopy are randomized to receive either usual care or nurse care management. Primary outcomes are: 1) the proportion with CRC screening, 2) the proportion with a complete diagnostic evaluation after a positive screening test. We sent recruitment letters to 15,414 patients and 4675 were randomized. Randomly assigned treatment groups were similar in age, sex, race, education, self-reported health, and CRC screening history. We will determine the effectiveness and cost effectiveness of stepped increases in systems of support to increase CRC screening and follow-up after a positive screening test over 2years. Copyright © 2010 Elsevier Inc. All rights reserved.
Disability and Preventive Cancer Screening: Results from the 2001 California Health Interview Survey
Ramirez, Anthony; Farmer, Gail C.; Grant, David; Papachristou, Theodora
2005-01-01
Objective. We sought to evaluate preventive cancer screening compliance among adults with disability in California. Methods. We used data from the 2001 California Health Interview Survey to compare disabled and nondisabled adults for differences in preventive cancer screening behaviors. Compliance rates for cancer screening tests (mammography, Papanicolaou test, prostate-specific antigen, sigmoidoscopy/colonoscopy, and fecal occult blood test) between the 2 subpopulations were evaluated. Results. Women with disabilities were 17% (Papanicolaou tests) and 13% (mammograms) more likely than women without disabilities to report noncompliance with cancer screening guidelines. Interactions between disability and reports of a doctor recommendation on cervical cancer screening were significant; women with disabilities had a lower likelihood of receiving a recommendation. Men with disabilities were 19% less likely than men without disabilities to report a prostate-specific antigen test within the last 3 years. Conclusions.secondary to structural and/or clinical factors underpinning the differences found. PMID:16195509
Lights, Camera, Spectroscope! The Basics of Spectroscopy Disclosed Using a Computer Screen
ERIC Educational Resources Information Center
Garrido-Gonza´lez, Jose´ J.; Trillo-Alcala´, María; Sa´nchez-Arroyo, Antonio J.
2018-01-01
The generation of secondary colors in digital devices by means of the additive red, green, and blue color model (RGB) can be a valuable way to introduce students to the basics of spectroscopy. This work has been focused on the spectral separation of secondary colors of light emitted by a computer screen into red, green, and blue bands, and how the…
Mathews, Miya Gugulethu; Ajayi, Oyemitan Idris; Opeoluwa, Oyedeji Oyehan; Oluwatobi, Oluwafemi Samuel; Benedicta N, Nkeh-Chungag; Phindile, Songca Sandile; Oyedeji; Omowumi, Adebola
2016-01-01
Background: Pentanisia prunelloides is a medicinal plant widely used to remedy various ailments including infections, fever and rheumatism in Eastern Cape Province of South Africa. There is scanty report on the phytochemical and biological properties of the plant; hence various solvent extracts of the dried plant materials were phytochemically screened, and its aqueous extract evaluated for acute toxicity effect, analgesic and antiinflammatory properties in rodents. Methods and Materials: Different extracts of both leaf and rhizome were obtained separately with ethanol, methanol and water. Portions of the filtrate were used for qualitative screening of secondary metabolites and remaining portions were concentrated and dried. Dried grounded leaf and rhizome of the plant were also used for quantitative screening for some major components. The aqueous extract of the leaf and rhizome were used for acute toxicity (LD50) test, antiinflammatory and analgesic activities in rodents. Results: The qualitative phytochemical screening showed the presence of several phytoconstituents with saponins, flavonoids and alkaloids constituting highest constituents in the leaf and rhizome. The LD50: of the aqueous extracts (from leaf or rhizome) was found to be ≥5000 mg/kg orally. The leaf and rhizome aqueous extract (250-500 mg/kg) significantly (p<0.01) reduced egg albumin-induced paw oedema and paw licking in mice induced by formalin, signifying antinociceptive and antiinflammatory activities respectively. Conclusion: It is concluded that the leaf and rhizome of P. prunelloides are rich in various phytochemicals which could be associated with their medicinal uses. The aqueous leaf and rhizome extracts are similarly non-toxic orally, showed antiinflammatory and analgesic potentials thus rationalizing its use in folkloric medicine. PMID:28480377
Node-pore sensing enables label-free surface-marker profiling of single cells.
Balakrishnan, Karthik R; Whang, Jeremy C; Hwang, Richard; Hack, James H; Godley, Lucy A; Sohn, Lydia L
2015-03-03
Flow cytometry is a ubiquitous, multiparametric method for characterizing cellular populations. However, this method can grow increasingly complex with the number of proteins that need to be screened simultaneously: spectral emission overlap of fluorophores and the subsequent need for compensation, lengthy sample preparation, and multiple control tests that need to be performed separately must all be considered. These factors lead to increased costs, and consequently, flow cytometry is performed in core facilities with a dedicated technician operating the instrument. Here, we describe a low-cost, label-free microfluidic method that can determine the phenotypic profiles of single cells. Our method employs Node-Pore Sensing to measure the transit times of cells as they interact with a series of different antibodies, each corresponding to a specific cell-surface antigen, that have been functionalized in a single microfluidic channel. We demonstrate the capabilities of our method not only by screening two acute promyelocytic leukemia human cells lines (NB4 and AP-1060) for myeloid antigens, CD13, CD14, CD15, and CD33, simultaneously, but also by distinguishing a mixture of cells of similar size—AP-1060 and NALM-1—based on surface markers CD13 and HLA-DR. Furthermore, we show that our method can screen complex subpopulations in clinical samples: we successfully identified the blast population in primary human bone marrow samples from patients with acute myeloid leukemia and screened these cells for CD13, CD34, and HLA-DR. We show that our label-free method is an affordable, highly sensitive, and user-friendly technology that has the potential to transform cellular screening at the benchside.
Implications of false-positive results for future cancer screenings.
Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B
2018-06-01
False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both P<.001). The same women were more likely to be up to date with colorectal cancer screening (AOR range, 1.25-1.47 depending on breast biopsy; both P<.001). Men who previously had false-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; P<.001). Patients who previously had a false-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.
Sefton, JoEllen M; Lohse, K R; McAdam, J S
2016-11-01
Musculoskeletal injuries (MSIs) are among the most important challenges facing our military. They influence career success and directly affect military readiness. Several methods of screening initial entry training (IET) soldiers are being tested in an effort to predict which soldiers will sustain an MSI and to develop injury-prevention programs. The Army 1-1-1 Fitness Assessment was examined to determine if it could be used as a screening and MSI prediction mechanism in male IET soldiers. To determine if a relationship existed among the Army 1-1-1 Fitness Assessment results and MSI, MSI type, and program of instruction (POI) in male IET soldiers. Retrospective cohort study. Fort Benning, Georgia. Male Army IET soldiers (N = 1788). The likelihood of sustaining acute and overuse MSI was modelled using separate logistic regression analyses. The POI, run time, push-ups and sit-ups (combined into a single score), and IET soldier age were tested as predictors in a series of linear models. With POI controlled, slower run time, fewer push-ups and sit-ups, and older age were positively correlated with acute MSI; only slower run time was correlated with overuse MSI. For both MSI types, cavalry POIs had a higher risk of acute and overuse MSIs than did basic combat training, armor, or infantry POIs. The 1-1-1 Fitness Assessment predicted both the likelihood of MSI occurrence and type of MSI (acute or overuse). One-mile (1.6-km) run time predicted both overuse and acute MSIs, whereas the combined push-up and sit-up score predicted only acute MSIs. The MSIs varied by type of training (infantry, basic, armor, cavalry), which allowed the development of prediction equations by POI. We determined 1-1-1 Fitness Assessment cutoff scores for each event, thereby allowing the evaluation to be used as an MSI screening mechanism for IET soldiers.
Sefton, JoEllen M.; Lohse, K. R.; McAdam, J. S.
2016-01-01
Context: Musculoskeletal injuries (MSIs) are among the most important challenges facing our military. They influence career success and directly affect military readiness. Several methods of screening initial entry training (IET) soldiers are being tested in an effort to predict which soldiers will sustain an MSI and to develop injury-prevention programs. The Army 1-1-1 Fitness Assessment was examined to determine if it could be used as a screening and MSI prediction mechanism in male IET soldiers. Objective: To determine if a relationship existed among the Army 1-1-1 Fitness Assessment results and MSI, MSI type, and program of instruction (POI) in male IET soldiers. Design: Retrospective cohort study. Setting: Fort Benning, Georgia. Patients or Other Participants: Male Army IET soldiers (N = 1788). Main Outcome Measure(s): The likelihood of sustaining acute and overuse MSI was modelled using separate logistic regression analyses. The POI, run time, push-ups and sit-ups (combined into a single score), and IET soldier age were tested as predictors in a series of linear models. Results: With POI controlled, slower run time, fewer push-ups and sit-ups, and older age were positively correlated with acute MSI; only slower run time was correlated with overuse MSI. For both MSI types, cavalry POIs had a higher risk of acute and overuse MSIs than did basic combat training, armor, or infantry POIs. Conclusions: The 1-1-1 Fitness Assessment predicted both the likelihood of MSI occurrence and type of MSI (acute or overuse). One-mile (1.6-km) run time predicted both overuse and acute MSIs, whereas the combined push-up and sit-up score predicted only acute MSIs. The MSIs varied by type of training (infantry, basic, armor, cavalry), which allowed the development of prediction equations by POI. We determined 1-1-1 Fitness Assessment cutoff scores for each event, thereby allowing the evaluation to be used as an MSI screening mechanism for IET soldiers. PMID:28068160
Wijtzes, Anne; van de Bongardt, Daphne; van de Looij-Jansen, Petra; Bannink, Rienke; Raat, Hein
2016-01-01
Objectives To assess the prospective associations of physical activity behaviors and screen time with early sexual intercourse initiation (i.e., before 15 years) in a large sample of adolescents. Methods We used two waves of data from the Rotterdam Youth Monitor, a longitudinal study conducted in the Netherlands. The analysis sample consisted of 2,141 adolescents aged 12 to 14 years (mean age at baseline = 12.2 years, SD = 0.43). Physical activity (e.g., sports outside school), screen time (e.g., computer use), and early sexual intercourse initiation were assessed by means of self-report questionnaires. Logistic regression models were tested to assess the associations of physical activity behaviors and screen time (separately and simultaneously) with early sexual intercourse initiation, controlling for confounders (i.e., socio-demographics and substance use). Interaction effects with gender were tested to assess whether these associations differed significantly between boys and girls. Results The only physical activity behavior that was a significant predictor of early sexual intercourse initiation was sports club membership. Adolescent boys and girls who were members of a sports club) were more likely to have had early sex (OR = 2.17; 95% CI = 1.33, 3.56. Significant gender interaction effects indicated that boys who watched TV ≥2 hours/day (OR = 2.00; 95% CI = 1.08, 3.68) and girls who used the computer ≥2 hours/day (OR = 3.92; 95% CI = 1.76, 8.69) were also significantly more likely to have engaged in early sex. Conclusion These findings have implications for professionals in general pediatric healthcare, sexual health educators, policy makers, and parents, who should be aware of these possible prospective links between sports club membership, TV watching (for boys), and computer use (for girls), and early sexual intercourse initiation. However, continued research on determinants of adolescents’ early sexual initiation is needed to further contribute to the strategies for improving adolescents’ healthy sexual development and behaviors. PMID:27513323
Gilmour, Matthew W.; DeGagne, Pat; Nichol, Kim; Karlowsky, James A.
2014-01-01
An efficient workflow to screen for and confirm the presence of carbapenemase-producing Gram-negative bacilli was developed by evaluating five chromogenic screening agar media and two confirmatory assays, the Rapid Carb screen test (Rosco Diagnostica A/S, Taastrup, Denmark) and the modified Hodge test. A panel of 150 isolates was used, including 49 carbapenemase-producing isolates representing a variety of β-lactamase enzyme classes. An evaluation of analytical performance, assay cost, and turnaround time indicated that the preferred workflow (screening test followed by confirmatory testing) was the chromID Carba agar medium (bioMérieux, Marcy l'Étoile, France), followed by the Rapid Carb screen test, yielding a combined sensitivity of 89.8% and a specificity of 100%. As an optional component of the workflow, a determination of carbapenemase gene class via molecular means could be performed subsequent to confirmatory testing. PMID:25355764
Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce
2012-02-01
Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.
Brondani, Mario; Chang, Steve; Donnelly, Leeann
2016-05-10
As a public health initiative, provided-initiated HIV screening test in dental settings has long been available in the U.S.; it was only in 2011 that such setting was used in Canada. The objective of this paper was to assess patients' response to, and attitudes towards, an opt-out rapid HIV screening test in a dental setting in Vancouver, Canada. A cross-sectional evaluation design using a self-complete survey questionnaire on self-perceived values and benefits of an opt-out rapid HIV screening was employed. An anonymous 10-item questionnaire was developed to explore reasons for accepting or declining the HIV rapid screening test, and barriers and facilitators for the HIV screening in dental settings. Eligible participants were male and female older than 19 years attending community dental clinics and who were offered the HIV screening test between June 2010 and February 2015. From the 1552 age-eligible patients, 519 completed the survey and 155 (10 %) accepted the HIV screening due to its convenience, and/or free cost, and/or instant results. From the 458 respondents who did not accept the screening, 362 (79 %) were between the ages of 25 and 45 years; 246 (53.7 %) had identifiable risk factors for contracting HIV; and 189 (41.3 %) reported having been tested within the last 3 months. Those tested in less than 3 months had 3.5 times higher odds to decline the HIV screening compared to those who have been tested between 3 months and 1 year. Convenience, cost-free and readily available results are factors influencing rapid HIV screening uptake. Although dental settings remain an alternative venue for HIV screening from the patients' perspectives, dental hygiene settings might offer a better option.
Screening for Colorectal Cancer: US Preventive Services Task Force Recommendation Statement.
Bibbins-Domingo, Kirsten; Grossman, David C; Curry, Susan J; Davidson, Karina W; Epling, John W; García, Francisco A R; Gillman, Matthew W; Harper, Diane M; Kemper, Alex R; Krist, Alex H; Kurth, Ann E; Landefeld, C Seth; Mangione, Carol M; Owens, Douglas K; Phillips, William R; Phipps, Maureen G; Pignone, Michael P; Siu, Albert L
2016-06-21
Colorectal cancer is the second leading cause of cancer death in the United States. In 2016, an estimated 134,000 persons will be diagnosed with the disease, and about 49,000 will die from it. Colorectal cancer is most frequently diagnosed among adults aged 65 to 74 years; the median age at death from colorectal cancer is 68 years. To update the 2008 US Preventive Services Task Force (USPSTF) recommendation on screening for colorectal cancer. The USPSTF reviewed the evidence on the effectiveness of screening with colonoscopy, flexible sigmoidoscopy, computed tomography colonography, the guaiac-based fecal occult blood test, the fecal immunochemical test, the multitargeted stool DNA test, and the methylated SEPT9 DNA test in reducing the incidence of and mortality from colorectal cancer or all-cause mortality; the harms of these screening tests; and the test performance characteristics of these tests for detecting adenomatous polyps, advanced adenomas based on size, or both, as well as colorectal cancer. The USPSTF also commissioned a comparative modeling study to provide information on optimal starting and stopping ages and screening intervals across the different available screening methods. The USPSTF concludes with high certainty that screening for colorectal cancer in average-risk, asymptomatic adults aged 50 to 75 years is of substantial net benefit. Multiple screening strategies are available to choose from, with different levels of evidence to support their effectiveness, as well as unique advantages and limitations, although there are no empirical data to demonstrate that any of the reviewed strategies provide a greater net benefit. Screening for colorectal cancer is a substantially underused preventive health strategy in the United States. The USPSTF recommends screening for colorectal cancer starting at age 50 years and continuing until age 75 years (A recommendation). The decision to screen for colorectal cancer in adults aged 76 to 85 years should be an individual one, taking into account the patient's overall health and prior screening history (C recommendation).
Johnson, David A; Barclay, Robert L; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T
2014-01-01
Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9-80.9%) and 68.0% (95% CI 58.2-76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5-86.3%) compared with 97.4% (95% CI 94.1-98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% -95% CI 62.5-80.1%) was shown to be statistically non-inferior to FIT (68.0%-95% CI 58.2-76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. ClinicalTrials.gov NCT01580540.
Zhang, Dapeng; Lu, Hongyan; Zhuang, Minghua; Wu, Guohui; Yan, Hongjing; Xu, Jun; Wei, Xiaoli; Li, Chengmei; Meng, Sining; Fu, Xiaojing; Qi, Jinlei; Wang, Peng; Luo, Mei; Dai, Min; Yip, Ray; Sun, Jiangping; Wu, Zunyou
2016-01-01
To explore models to improve HIV testing, linkage to care and treatment among men who have sex with men (MSM) in cooperation with community-based organizations (CBOs) in China. We introduced a new model for HIV testing services targeting MSM in six cities in 2013.These models introduced provision of rapid HIV testing by CBO staff and streamlined processes for HIV screening, confirmation of initial reactive screening results, and linkage to care among diagnosed people. We monitored attrition along each step of the continuum of care from screening to treatment and compared program performance between 2012 and 2013. According to the providers of two rapid tests (HIV screening), four different services delivery models were examined in 2013: Model A = first screen at CDC, second at CDC (Model A = CDC+CDC), Model B = first and second screens at CBOs (Model B = CBO+CBO), Model C = first screen at CBO, second at Hospital (Model C = CBO+Hosp), and Model D = first screen at CBO, second at CDC (Model D = CBO+CDC). Logistic regressions were performed to assess advantages of different screening models of case finding and case management. Compared to 2012, the number of HIV screening tests performed for MSM increased 35.8% in 2013 (72,577 in 2013 vs. 53,455 in 2012). We observed a 5.6% increase in proportion of cases screened reactive receiving HIV confirmatory tests (93.9% in 2013 vs. 89.2% in 2012, χ2 = 48.52, p<0.001) and 65% reduction in loss to CD4 cell count tests (15% in 2013 vs. 43% in 2012, χ2 = 628.85, p<0.001). Regarding linkage to care and treatment, the 2013 pilot showed that the Model D had the highest rate of loss between screening reactive and confirmatory test among the four models, with 18.1% fewer receiving a second screening test and a further 5.9% loss among those receiving HIV confirmatory tests. The Model B and the Model C showed lower losses (0.8% and 1.3%) for newly diagnosed HIV positives receiving CD4 cell count tests, and higher rates of HIV positives referred to designated ART hospitals (88.0% and 93.3%) than the Model A and Model D (4.6% and 5.7% for CD4 cell count test, and 68.9% and 64.4% for referring to designated ART hospitals). The proportion of cases where the screening test was reactive that were commenced on ART was highest in Model C; 52.8% of cases commenced on ART compared to 38.9%, 34.2% and 21.1% in Models A, B and D respectively. Using Model A as a reference group, the multivariate logistic regression results also showed the advantages of Models B, C and D, which increased CD4 cell count test, referral to designated ART hospitals and initiation of ART, when controlling for program city and other factors. This study has demonstrated that involvement of CBOs in HIV rapid testing provision, streamlining testing and care procedures and early hospital case management can improve testing, linkage to, and retention in care and treatment among MSM in China.
Development of an Attitudes Measure for Prenatal Screening in Diverse Populations
ERIC Educational Resources Information Center
Posner, S. F.; Learman, L. A.; Gates, E. A.; Washington, A. E.; Kuppermann, M.
2004-01-01
Background: Prenatal screening for chromosomal abnormalities is routinely offered to all pregnant women who present for care by their 20th gestational week. Not all women, however, choose to undergo one of these tests, and choice of which test(s) to undergo also vary. The reasons for variation in screening test behavior have not been fully…
Rourk, Angela R; Nolte, Frederick S; Litwin, Christine M
2016-11-01
With the recent introduction of automated treponemal tests, a new reverse syphilis algorithm has been proposed and now used by many clinical laboratories. We analyzed the impact of instituting the reverse screening syphilis algorithm in a laboratory that serves a geographic area with a moderately high prevalence of syphilis infection. Serum samples sent for syphilis testing were tested using a treponemal enzyme immunoassay (EIA) as the screening assay. EIA reactive samples were tested by rapid plasma reagin (RPR) and titered to end point if reactive. RPR nonreactive samples were analyzed by the Treponema pallidum particle agglutination test (TP-PA). Pertinent medical records were reviewed for false-reactive screens and samples with evidence of past syphilis infection. Among 10,060 patients tested, 502 (5%) were reactive on the initial EIA screen. The RPR was reactive in 150 (1.5%). TP-PA testing determined that 103 (1.0%) were falsely reactive on initial EIA screen. The reverse screening algorithm, however, identified 242 (2.4%) with evidence of latent, secondary, or past syphilis, 21 of whom had no or unknown prior treatment with antibiotics. Despite a 1.0% false-reactive rate, the reverse syphilis algorithm detected 21 patients with possible latent syphilis that may have gone undetected by traditional syphilis screening. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
An audit of the cervical cancer screening histories of 246 women with carcinoma.
Duggan, Máire A; Nation, Jill
2012-07-01
Women with cervical carcinoma and residing in the Calgary Health Region between 1996 and 2001 were audited to characterize factors in the opportunistic cervical cancer screening pathway contributing to screening failures. The cohort consisted of 246 women. Information on their Pap tests and colposcopic/gynecologic examinations was obtained from the files of Calgary Laboratory Services and their colposcopic/cancer center treatment charts. Screening failure factors were defined, and frequencies were calculated. Screening failure factors were as follows: (1) 41 (16.7%) were not screened, that is, no Pap test screening; (2) 29 (11.8%) were underscreened, that is, no Pap test within 12 months of diagnosis; (3) 28 (13.7%) were undersampled, that is, the Pap test result was negative; (4) 34 (13.8%) had no referral for a colposcopy/gynecology examination, and/or it was delayed for more than 3 months; (5) 18 (13.2%) had delayed referral for examination of an atypical glandular cell-high-grade squamous intraepithelial lesion and higher Pap test for more than 3 months; and (6) 73 (55.3%) were underdiagnosed, that is, the diagnosis in colposcopy examination was less than malignant. Underreported Pap tests and delayed Pap test reporting could not be fully investigated, but limited evidence suggested that underreporting contributed to some failures. Factors other than recruitment to cytological screening need targeted improvement if the region's cervical cancer prevention program is to be more effective.
How to improve colon cancer screening rates
Alberti, Luiz Ronaldo; Garcia, Diego Paim Carvalho; Coelho, Debora Lucciola; De Lima, David Correa Alves; Petroianu, Andy
2015-01-01
Colorectal carcinoma is a common cause of death throughout the world and may be prevented by routine control, which can detect precancerous neoplasms and early cancers before they undergo malignant transformation or metastasis. Three strategies may improve colon cancer screening rates: convince the population about the importance of undergoing a screening test; achieve higher efficacy in standard screening tests and make them more available to the community and develop new more sensitive and efficacious screening methods and make them available as routine tests. In this light, the present study seeks to review these three means through which to increase colon cancer screening rates. PMID:26688708
Screening for colorectal cancer.
He, Jin; Efron, Jonathan E
2011-01-01
March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.
Reanalysis of in situ permeability measurements in the Barbados décollement
Bekins, B.A.; Matmon, D.; Screaton, E.J.; Brown, K.M.
2011-01-01
A cased and sealed borehole in the Northern Barbados accretionary complex was the site of the first attempts to measure permeability in situ along a plate boundary décollement. Three separate efforts at Hole 949C yielded permeability estimates for the décollement spanning four orders of magnitude. An analysis of problems encountered during installation of the casing and seals provides insights into how the borehole conditions may have led to the wide range of results. During the installation, sediments from the surrounding formation repeatedly intruded into the borehole and casing. Stress analysis shows that the weak sediments were deforming plastically and the radial and tangential stresses around the borehole were significantly lower than lithostatic. This perturbed stress state may explain why the test pressure records showed indications of hydrofracture at pressures below lithostatic, and permeabilities rose rapidly as the estimated effective stress dropped below 0.8 MPa. Even after the borehole was sealed, the plastic deformation of the formation and relatively large gap of the wire wrapped screen allowed sediment to flow into the casing. Force equilibrium calculations predict sediment would have filled the borehole to 10 cm above the top of the screen by the time slug tests were conducted 1.5 years after the borehole was sealed. Reanalysis of the slug test results with these conditions yields several orders of magnitude higher permeability estimates than the original analysis which assumed an open casing. Overall the results based on only the tests with no sign of hydrofracture yield a permeability range of 10−14–10−15 m2 and a rate of increase in permeability with decreasing effective stress consistent with laboratory tests on samples from the décollement zone.
Colorectal Cancer Screening in Average Risk Populations: Evidence Summary.
Tinmouth, Jill; Vella, Emily T; Baxter, Nancy N; Dubé, Catherine; Gould, Michael; Hey, Amanda; Ismaila, Nofisat; McCurdy, Bronwen R; Paszat, Lawrence
2016-01-01
Introduction. The objectives of this systematic review were to evaluate the evidence for different CRC screening tests and to determine the most appropriate ages of initiation and cessation for CRC screening and the most appropriate screening intervals for selected CRC screening tests in people at average risk for CRC. Methods. Electronic databases were searched for studies that addressed the research objectives. Meta-analyses were conducted with clinically homogenous trials. A working group reviewed the evidence to develop conclusions. Results. Thirty RCTs and 29 observational studies were included. Flexible sigmoidoscopy (FS) prevented CRC and led to the largest reduction in CRC mortality with a smaller but significant reduction in CRC mortality with the use of guaiac fecal occult blood tests (gFOBTs). There was insufficient or low quality evidence to support the use of other screening tests, including colonoscopy, as well as changing the ages of initiation and cessation for CRC screening with gFOBTs in Ontario. Either annual or biennial screening using gFOBT reduces CRC-related mortality. Conclusion. The evidentiary base supports the use of FS or FOBT (either annual or biennial) to screen patients at average risk for CRC. This work will guide the development of the provincial CRC screening program.
Serrani Azcurra, D J L
2013-10-01
There is a need for clinically administered instruments capable of detecting executive dysfunction in dementia. The translation and validation of Executive Battery 25 (EB25) and a short version for screening of executive dysfunction in dementia. The original battery was translated and validated using convergent and divergent correlation in 66 mild dementia patients (CDR 1) matched with 66 controls. EB25 consists of 25 items which detect executive dysfunction. Convergent correlation was made with 7 tests assessing executive dysfunction, the Frontal Systems Behaviour Scale (FrSBe) and Disability Fast Assessment Scale. Patients had higher scores than controls and correlated with the Stroop Test, verbal fluency test and Frontal Behaviour Inventory. Only 12 out of 25 items were needed to separate both groups, which were used to build an abbreviated Executive Battery with equal psychometric properties and discriminative power. The cut-off point for EB25 was 12, and 7 for the abbreviated version. A cut-off point of 12 was able to discriminate between ¿Alzheimer's disease? (AD) and frontotemporal lobe dementia (FTLD). EB25 and AEB12 enable executive dysfunction to be detected in mild dementia. On the other hand, AEB12 exhibits better psychometric properties than the original battery, allowing discrimination between AD and FTLD and is completed in less time. Copyright © 2010 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.
Saraiya, M.; Steben, M.; Watson, M.; Markowitz, L.
2015-01-01
Objective Declines in cervical cancer incidence and mortality in Canada and in the United States have been widely attributed to the introduction of the Papanicolaou (Pap) test. This article reviews changes in screening and introduction of HPV vaccination. Method Sentinel events in cervical cancer screening and primary prevention through HPV vaccination in the US and Canada are described. Results Despite commonalities, cervical cancer screening and prevention differ between the two countries. Canada has a combination of opportunistic and organized programs at the provincial and territorial level, while the US has opportunistic screening and vaccination systems. In the US, the HPV test along with the Pap test (co-testing) is part of national recommendations for routine cervical cancer screening for women age 30 and older. Co-testing is not being considered anywhere in Canada, but primary HPV testing is currently recommended (but not implemented) in one province in Canada. Conclusion Many prevention strategies are available for cervical cancer. Continued public health efforts should focus on increasing vaccine coverage in the target age groups and cervical cancer screening for women at appropriate intervals. Ongoing evaluation will be needed to ensure appropriate use of health resources, as vaccinated women become eligible for screening. PMID:23402963
Herzog, Sereina A; Heijne, Janneke C M; Scott, Pippa; Althaus, Christian L; Low, Nicola
2013-11-01
Pelvic inflammatory disease (PID) results from the ascending spread of microorganisms, including Chlamydia trachomatis, to the upper genital tract. Screening could improve outcomes by identifying and treating chlamydial infections before they progress to PID (direct effect) or by reducing chlamydia transmission (indirect effect). We developed a compartmental model that represents a hypothetical heterosexual population and explicitly incorporates progression from chlamydia to clinical PID. Chlamydia screening was introduced, with coverage increasing each year for 10 years. We estimated the separate contributions of the direct and indirect effects of screening on PID cases prevented per 100,000 women. We explored the influence of varying the time point at which clinical PID could occur and of increasing the risk of PID after repeated chlamydial infections. The probability of PID at baseline was 3.1% by age 25 years. After 5 years, the intervention scenario had prevented 187 PID cases per 100,000 women and after 10 years 956 PID cases per 100,000 women. At the start of screening, most PID cases were prevented by the direct effect. The indirect effect produced a small net increase in PID cases, which was outweighed by the effect of reduced chlamydia transmission after 2.2 years. The later that progression to PID occurs, the greater the contribution of the direct effect. Increasing the risk of PID with repeated chlamydial infection increases the number of PID cases prevented by screening. This study shows the separate roles of direct and indirect PID prevention and potential harms, which cannot be demonstrated in observational studies.
Screening for diabetes in optometry practices: acceptability to users.
Howse, Jennifer H; Jones, Steve; Hungin, A Pali S
2011-07-01
Diabetes is a leading cause of blindness in the working age population. While optometrists have an established role in screening people with known diabetes for eye disease, their role in screening for diabetes has not been evaluated. For diabetes screening in optometry practices to be successful it must be acceptable to both optometrists and to the public. The purpose of this study was to determine acceptability to people attending optometry practices of using random capillary blood glucose (rCBG) tests to detect raised blood glucose levels in optometry practices. A screening service offering people with risk factors or symptoms of diabetes rCBG tests was piloted in five high street opticians' practices in North East England. One thousand and two people used the screening service during a 20 week period. Each was given a questionnaire to complete and return following a rCBG test. Nine hundred and thirty-nine questionnaires were returned (return rate 93.7%). The mean age of participants was 54.5 years, 63.3% were female and 75.0% had not been screened for diabetes previously. 99.1% agreed or strongly agreed that the location was convenient for them and 98.0% would recommend others to use the screening service. 83.8% of the participants would not have gone elsewhere to have any tests done and 148 (16.2%) responded that they would have sought a test elsewhere; 14.2% at the GP, 0.8% at a pharmacy and 0.5% elsewhere. Only 3.2% reported that the test procedure was uncomfortable. To those attending opticians' practices, screening using rCBG tests is acceptable in terms of convenience and test comfort, and they would recommend the test to others. Screening in optometry practices provides an opportunity to identify people at risk of diabetes in a hitherto unutilised setting. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.
A Screening Test for Wilson's Disease and its Application to Psychiatric Patients
Cox, Diane Wilson
1967-01-01
Varied modes of onset make the early diagnosis of Wilson's disease difficult. A deficiency of serum ceruloplasmin, usually characteristic of the disease, was used as the basis for a screening test. Simple test materials and provision for handling about 50 plasma samples simultaneously made this test feasible for large-scale screening. The screening test was applied to 336 persons hospitalized for psychiatric disorders, to detect patients with Wilson's disease before the classical symptoms appeared. Two patients with ceruloplasmin levels below the normal limits were detected but did not have Wilson's disease. Further application of the screening test to relatives of patients known to have Wilson's disease and to individuals with any symptoms of the disease (hepatic disease, extrapyramidal dysfunction, psychiatric disorders, behaviour problems in children) would aid in early diagnosis and more effective treatment. ImagesFig. 1 PMID:6017170