Sample records for sequential biventricular pacing

  1. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator.

    PubMed

    Khoo, Clarence; Bennett, Matthew; Chakrabarti, Santabhanu; LeMaitre, John; Tung, Stanley K K

    2013-02-01

    A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS. This strategy obviates the need to reduce ventricular sensitivity and thus may be an effective alternative to biventricular pacing complicated by TWOS. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  2. Left Ventricular Reverse Remodeling With Biventricular Versus Right Ventricular Pacing in Patients With Atrioventricular Block and Heart Failure in the BLOCK HF Trial.

    PubMed

    St John Sutton, Martin; Plappert, Ted; Adamson, Philip B; Li, Pei; Christman, Shelly A; Chung, Eugene S; Curtis, Anne B

    2015-05-01

    Biventricular pacing in heart failure (HF) improves survival, relieves symptoms, and attenuates left ventricular (LV) remodeling. However, little is known about biventricular pacing in HF patients with atrioventricular block because they are typically excluded from biventricular trials. The Biventricular versus Right Ventricular Pacing in Heart Failure Patients with Atrioventricular Block (BLOCK HF) trial randomized patients with atrioventricular block, New York Heart Association symptom classes I to III HF, and LV ejection fraction ≤50% to biventricular or right ventricular pacing. Doppler echocardiograms were obtained at randomization (after 30 to 60 days of right ventricular pacing postimplant) and every 6 months through 24 months. Data analysis comparing changes in 10 prespecified echo parameters over time was conducted using a Bayesian design. LV end systolic volume index was also evaluated as a predictor of mortality/morbidity. Of 691 randomized subjects, 624 had paired Doppler echocardiogram data for ≥1 analyses at 6, 12, 18, or 24 months. Biventricular pacing significantly reduced LV volume indices and intraventricular mechanical delay, and improved LV ejection fraction, consistent with LV reverse remodeling. These parameters showed little change with right ventricular pacing alone, indicating no systematic reverse remodeling with right ventricular pacing. LV end systolic volume index was predictive of mortality/morbidity; the estimated risk increased up to 1% for every 1 mL/m(2) increase in LV end systolic volume index. LV end systolic volume index is a significant predictor of mortality/morbidity in this population. Cardiac structure and function are improved with biventricular pacing for patients with atrioventricular block and LV systolic dysfunction. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00267098. © 2015 American Heart Association, Inc.

  3. Optimal pacing for right ventricular and biventricular devices: minimizing, maximizing, and right ventricular/left ventricular site considerations.

    PubMed

    Gillis, Anne M

    2014-10-01

    The results from numerous clinical studies provide guidance for optimizing outcomes related to RV or biventricular pacing in the pacemaker and ICD populations. (1) Programming algorithms to minimize RV pacing is imperative in patients with dual-chamber pacemakers who have intrinsic AV conduction or intermittent AV conduction block. (2) Dual-chamber ICDs should be avoided in candidates without an indication for bradycardia pacing. (3) Alternate RV septal pacing sites may be considered at the time of pacemaker implantation. (4) Biventricular pacing may be beneficial in some patients with mild LV dysfunction. (5) LV lead placement at the site of latest LV activation is desirable. (6) Programming CRT systems to achieve biventricular/LV pacing >98.5% is important. (7) Protocols for AV and VV optimization in patients with CRT are not recommended after device implantation but may be considered for CRT nonresponders. (8) Novel algorithms to maximize the benefit of CRT are in evolution further.

  4. Right heart failure due to loss of right ventricular capture in a patient with atrioventricular junction ablation and biventricular pacing.

    PubMed

    Raffa, Santi; Fantoni, Cecilia; Restauri, Luigia; Auricchio, Angelo

    2005-10-01

    We describe the case of a patient with atrioventricular (AV) junction ablation and chronic biventricular pacing in which intermittent dysfunction of the right ventricular (RV) lead resulted in left ventricular (LV) stimulation alone and onset of severe right heart failure. Restoration of biventricular pacing by increasing device output and then performing lead revision resolved the issue. This case provides evidence that LV pacing alone in patients with AV junction ablation may lead to severe right heart failure, most likely as a result of iatrogenic mechanical dyssynchrony within the RV. Thus, probably this pacing mode should be avoided in pacemaker-dependent patients with heart failure.

  5. Temporary epicardial cardiac resynchronisation versus conventional right ventricular pacing after cardiac surgery: study protocol for a randomised control trial.

    PubMed

    Russell, Stuart J; Tan, Christine; O'Keefe, Peter; Ashraf, Saeed; Zaidi, Afzal; Fraser, Alan G; Yousef, Zaheer R

    2012-02-20

    Heart failure patients with stable angina, acute coronary syndromes and valvular heart disease may benefit from revascularisation and/or valve surgery. However, the mortality rate is increased- 5-30%. Biventricular pacing using temporary epicardial wires after surgery is a potential mechanism to improve cardiac function and clinical endpoints. A multi-centred, prospective, randomised, single-blinded, intervention-control trial of temporary biventricular pacing versus standard pacing. Patients with ischaemic cardiomyopathy, valvular heart disease or both, an ejection fraction ≤ 35% and a conventional indication for cardiac surgery will be recruited from 2 cardiac centres. Baseline investigations will include: an electrocardiogram to confirm sinus rhythm and measure QRS duration; echocardiogram to evaluate left ventricular function and markers of mechanical dyssynchrony; dobutamine echocardiogram for viability and blood tests for renal function and biomarkers of myocardial injury- troponin T and brain naturetic peptide. Blood tests will be repeated at 18, 48 and 72 hours. The principal exclusions will be subjects with permanent atrial arrhythmias, permanent pacemakers, infective endocarditis or end-stage renal disease.After surgery, temporary pacing wires will be attached to the postero-lateral wall of the left ventricle, the right atrium and right ventricle and connected to a triple chamber temporary pacemaker. Subjects will be randomised to receive either temporary biventricular pacing or standard pacing (atrial inhibited pacing or atrial-synchronous right ventricular pacing) for 48 hours.The primary endpoint will be the duration of level 3 care. In brief, this is the requirement for invasive ventilation, multi-organ support or more than one inotrope/vasoconstrictor. Haemodynamic studies will be performed at baseline, 6, 18 and 24 hours after surgery using a pulmonary arterial catheter. Measurements will be taken in the following pacing modes: atrial inhibited; right ventricular only; atrial synchronous-right ventricular; atrial synchronous-left ventricular and biventricular pacing. Optimisation of the atrioventricular and interventricular delay will be performed in the biventricular pacing group at 18 hours. The effect of biventricular pacing on myocardial injury, post operative arrhythmias and renal function will also be quantified. ClinicalTrials.gov: NCT01027299.

  6. Wall Thickness, Pulmonary Hypertension, and Diastolic Filling Abnormalities Predict Response to Postoperative Biventricular Pacing

    PubMed Central

    Brusen, Robin M.; Hahn, Rebecca; Cabreriza, Santos E.; Cheng, Bin; Wang, Daniel Y.; Truong, Wanda; Spotnitz, Henry M.

    2017-01-01

    Objective Post-cardiopulmonary bypass biventricular pacing improves hemodynamics but without clearly defined predictors of response. Based on preclinical studies and prior observations, it was suspected that diastolic dysfunction or pulmonary hypertension is predictive of hemodynamic benefit. Design Randomized controlled study of temporary biventricular pacing after cardiopulmonary bypass. Setting Single-center study at university-affiliated tertiary care hospital. Interventions Patients who underwent bypass with pre-operative ejection fraction ≤40% and QRS duration ≥100 ms or double-valve surgery were enrolled. At 3 time points between separation from bypass and postoperative day 1, pacing delays were varied to optimize hemodynamics. Participants Data from 43 patients were analyzed. Measurements and Main Results Cardiac output and arterial pressure were measured under no pacing, atrial pacing, and biventricular pacing. Preoperative echocardiograms and pulmonary artery catheterizations were reviewed, and measures of both systolic and diastolic function were compared to hemodynamic response. Early after separation, improvement in cardiac output was positively correlated with pulmonary vascular resistance (R2 = 0.97, p < 0.001), ventricle wall thickness (R2 = 0.72, p = 0.002)), and E/e′, a measure of abnormal diastolic ventricular filling velocity (R2 = 0.56, p = 0.04). Similar trends were seen with mean arterial pressure. QRS duration and ejection fraction did not correlate significantly with improvements in hemodynamics. Conclusions There may be an effect of biventricular pacing related to amelioration of abnormal diastolic filling patterns rather than electrical resynchronization in the postoperative state. PMID:25998068

  7. Canine left ventricle electromechanical behavior under different pacing modes.

    PubMed

    Vo Thang, Thanh-Thuy; Thibault, Bernard; Finnerty, Vincent; Pelletier-Galarneau, Matthieu; Khairy, Paul; Grégoire, Jean; Harel, François

    2012-10-01

    Cardiac resynchronization therapy may improve survival and quality of life in patients suffering from heart failure with left ventricular (LV) contraction dyssynchrony. While several studies have investigated electrical or mechanical determinants of synchronous contraction, few have focused on activation contraction coupling at a macroscopic level. The objective of the study was to characterize LV electromechanical behavior and response to pacing in a heart failure model. We analyzed data from 3D electroanatomic non-contact mapping and blood pool SPECT for 12 dogs with right ventricular (RV) tachycardia pacing-induced dilated cardiomyopathy. Surfaces generated by the two modalities were registered. Electrical signals were analyzed, and endocardial wall displacement curves were portrayed. Rapid pacing decreased the mean LV ejection fraction (LVEF) to 20.9 % and prolonged the QRS duration to 79 ± 10 ms (normal range: 40-50 ms). QRS duration remained unchanged with biventricular pacing (88.5 ms), while single site pacing further prolonged the QRS duration (113.3 ms for RV pacing and 111.6 ms for LV pacing). No trend was observed in LV systolic function. Activation duration time was significantly increased with all pacing modes compared to baseline. Finally, electromechanical delay, as defined by the delay between electrical activation and mechanical response, was increased by single site pacing (172.9 ms for RV pacing and 174.6 ms for LV pacing) but not by biventricular pacing (162.4 ms). Combined temporal and spatial coregistration electroanatomic maps and baseline gated blood pool SPECT imaging allowed us to quantify activation duration time, electromechanical delay, and LVEF for different pacing modes. Even if pacing modes did not significantly modify LVEF or activation duration, they produced alterations in electromechanical delay, with biventricular pacing significantly decreasing the electromechanical delay as measured by surface tracings and endocardial non-contact mapping.

  8. Transesophageal Echocardiography-Guided Epicardial Left Ventricular Lead Placement by Video-Assisted Thoracoscopic Surgery in Nonresponders to Biventricular Pacing and Previous Chest Surgery.

    PubMed

    Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar

    2018-06-14

    The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.

  9. Implantation techniques and chronic lead parameters of biventricular pacing dual-chamber defibrillators.

    PubMed

    Daoud, Emile G; Kalbfleisch, Steven J; Hummel, John D; Weiss, Raul; Augustini, Ralph S; Duff, Steven B; Polsinelli, Georgia; Castor, John; Meta, Tejas

    2002-10-01

    The aim of this study is to describe implantation techniques and lead performance for biventricular pacing, dual-chamber implantable cardioverter defibrillators (ICDs). A dual-chamber ICD with biventricular pacing was implanted in 87 patients with congestive heart failure (ejection fraction: 0.21 +/- 0.09), prolonged QRS duration (161 +/- 22 msec), and an indication for ICD therapy. Left ventricular pacing was achieved with a thoracotomy approach (n = 21) or a nonthoracotomy approach (n = 66). With a thoracotomy, biventricular devices were implanted successfully in all patients. During follow-up (17 +/- 11 months), 9 patients died (43%), 2 underwent transplantation, and 2 required left ventricular lead revision. At last follow-up, biventricular sensing and capture threshold were 11 +/- 5 mV and 1.5 +/- 0.8 V, respectively. For nonthoracotomy procedures, two types of coronary sinus (CS) leads were implanted: an over-the-wire lead (n = 45) and a shaped lead (n = 21). The rate of successful implantation (overall: 89%) (over-the-wire 93% vs shaped 81%; P = 0.1) and durations for CS lead placement (66 +/- 50 vs 58 +/- 34 min, P = 0.6) and the procedure (133 +/- 58 vs 129 +/- 33 min, P = 0.8) were not different between the two CS leads. During follow-up (11 +/- 9 months), 9 patients died (14%), and the shaped CS lead dislodged in 3 patients (3 shaped vs 0 over-the-wire, P = 0.01). At last follow-up, biventricular sensing and capture threshold were 10 +/- 4 mV and 1.8 +/- 0.7 V, respectively, and there was no difference between over-the-wire and shaped leads. By multivariate analysis, mortality was associated with absence of spironolactone therapy but not procedural features. Nonthoracotomy CS lead implantation is feasible, with a success rate of about 90% and few adverse events. For the remaining 10%, a thoracotomy approach can be completed safely in these ill patients without increased risk for death.

  10. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    PubMed

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  11. Prevention of Adverse Electrical and Mechanical Remodeling with Bi-Ventricular Pacing in a Rabbit Model of Myocardial Infarction

    PubMed Central

    Saba, Samir; Mathier, Michael A.; Mehdi, Haider; Gursoy, Erdal; Liu, Tong; Choi, Bum-Rak; Salama, Guy; London, Barry

    2008-01-01

    Background: Biventricular (BIV) pacing can improve cardiac function in heart failure (HF). Objective: To investigate the mechanisms of benefit of BIV pacing using a rabbit model of myocardial infarction (MI). Methods: New Zealand White rabbits were divided into 4 groups: sham-operated (C), MI with no pacing (MI), MI with right ventricular pacing (MI+RV), and MI with BIV pacing (MI+BIV), and underwent serial electrocardiograms and echocardiograms. At 4 weeks, hearts were excised and tissue was extracted from various areas of the left ventricle (LV). Results: Four weeks after coronary ligation, BIV pacing prevented systolic and diastolic dilation of the LV as well as the reduction in its fractional shortening, restored the QRS width and the rate-dependent QT intervals to their baseline values, and prevented the decline of the ether-a-go-go (erg) protein levels. This prevention of remodeling was not documented in the MI+RV groups. Conclusions: In this rabbit model of BIV pacing and MI, we demonstrate prevention of adverse mechanical and electrical remodeling of the heart. These changes may underlie some of the benefits seen with BIV pacing in HF patients with more severe LV dysfunction. PMID:18180026

  12. Late deterioration of left ventricular function after right ventricular pacemaker implantation.

    PubMed

    Bellmann, Barbara; Muntean, Bogdan G; Lin, Tina; Gemein, Christopher; Schmitz, Kathrin; Schauerte, Patrick

    2016-09-01

    Right ventricular (RV) pacing induces a left bundle branch block pattern on ECG and may promote heart failure. Patients with dual chamber pacemakers (DCPs) who present with progressive reduction in left ventricular ejection fraction (LVEF) secondary to RV pacing are candidates for cardiac resynchronization therapy (CRT). This study analyzes whether upgrading DCP to CRT with the additional implantation of a left ventricular (LV) lead improves LV function in patients with reduced LVEF following DCP implantation. Twenty-two patients (13 males) implanted with DCPs and a high RV pacing percentage (>90%) were evaluated in term of new-onset heart failure symptoms. The patients were enrolled in this retrospective single-center study after obvious causes for a reduced LVEF were excluded with echocardiography and coronary angiography. In all patients, DCPs were then upgraded to biventricular devices. LVEF was analyzed with a two-sided t-test. QRS duration and brain natriuretic peptide (BNP) levels were analyzed with the unpaired t-test. LVEF declined after DCP implantation from 54±10% to 31±7%, and the mean QRS duration was 161±20 ms during RV pacing. NT-pro BNP levels were elevated (3365±11436 pmol/L). After upgrading to a biventricular device, a biventricular pacing percentage of 98.1±2% was achieved. QRS duration decreased to 108±16 ms and 106±20 ms after 1 and 6 months, respectively. There was a significant increase in LVEF to 38±8% and 41±11% and a decrease in NT-pro BNP levels to 3088±2326 pmol/L and 1860±1838 pmol/L at 1 and 6 months, respectively. Upgrading to CRT may be beneficial in patients with DCPs and heart failure induced by a high RV pacing percentage.

  13. Direct His bundle pacing post AVN ablation.

    PubMed

    Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar

    2009-08-01

    Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.

  14. Biventricular non-compaction hypertrophic cardiomyopathy in association with congenital complete heart block and type I mitochondrial complex deficiency.

    PubMed

    Dhar, Ranjana; Reardon, William; McMahon, Colin J

    2015-06-01

    We report a baby girl with an antenatal diagnosis of biventricular non-compaction and complete heart block detected at 22 weeks' gestation. Postnatal echocardiography confirmed severe biventricular non-compaction hypertrophic cardiomyopathy, multiple muscular ventricular septal defects, and mild-moderate pulmonary valve stenosis. Skeletal muscle biopsy confirmed complex 1 mitochondrial respiratory chain deficiency. An epicardial VVI pacemaker was implanted on day 3 of life and revised at 7 years of age. She remains stable at 8 years of age following pacing and medical treatment with carvedilol, aspirin, co-enzyme Q10, and carnitine. This represents the first report of biventricular non-compaction hypertrophic phenotype in association with congenital complete heart block and complex 1 mitochondrial respiratory chain deficiency in a child.

  15. Effect of Right Ventricular versus Biventricular Pacing on Electrical Remodeling in the Normal Heart

    PubMed Central

    Saba, Samir; Mehdi, Haider; Mathier, Michael A.; Islam, M. Zahadul; Salama, Guy; London, Barry

    2010-01-01

    Background Biventricular (BIV) pacing can improve cardiac function in heart failure by altering the mechanical and electrical substrates. We investigated the effect of BIV versus right ventricular (RV) pacing on the normal heart. Methods and Results Male New Zealand White rabbits (n=33) were divided into 3 groups: sham-operated (control), RV pacing, and BIV pacing groups. Four weeks after surgery, the native QT (p=0.004) interval was significantly shorter in the BIV group compared to the RV or sham-operated groups. Also, compared to rabbits in the RV group, rabbits in the BIV group had shorter RV ventricular effective refractory period (VERP) at all cycle lengths, and shorter LV paced QT interval during the drive train of stimuli and close to refractoriness (p<0.001 for all comparisons). Protein expression of the KVLQT1 was significantly increased in the BIV group compared to the RV and control groups, while protein expression of SCN5A and connexin43 was significantly decreased in the RV compared to the other study groups. Erg protein expression was significantly increased in both pacing groups compared to the controls. Conclusions In this rabbit model, we demonstrate a direct effect of BIV but not RV pacing on shortening the native QT interval as well as the paced QT interval during burst pacing and close to the VERP. These findings underscore the fact that the effect of BIV pacing is partially mediated through direct electrical remodeling and may have implications as to the effect of BIV pacing on arrhythmia incidence and burden. PMID:20042767

  16. Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

    PubMed

    Maessen, J G; Phelps, B; Dekker, A L A J; Dijkman, B

    2004-05-01

    To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even the smallest changes in lead position revealed significantly different functional results. Optimizing the pacing site with this technique allowed functional improvement up to 40% versus random pace site selection.

  17. An algorithm for verifying biventricular capture based on evoked-response morphology.

    PubMed

    Diotallevi, Paolo; Ravazzi, Pier Antonio; Gostoli, Enrico; De Marchi, Giuseppe; Militello, Carmelo; Kraetschmer, Hannes

    2005-01-01

    Cardiac resynchronization therapy relies on consistent beat-by-beat myocardial capture in both ventricles. A pacemaker ensuring right (RV) and left ventricular (LV) capture through reliable capture verification and automatic output adjustment would contribute to patients' safety and quality of life. We studied the feasibility of an algorithm based on evoked-response (ER) morphology for capture verification in both the ventricles. RV and LV ER signals were recorded in 20 patients (mean age 72.5 years, range 64.3-80.4 years, 4 females and 16 males) during implantation of biventricular (BiV) pacing systems. Leads of several manufacturers were tested. Pacing and intracardiac electrogram (IEGM) recording were performed using an external pulse generator. IEGM and surface-lead electrocardiogram (ECG) signals were recorded under different pacing conditions for 10 seconds each: RV pacing only, LV pacing only, and BiV pacing with several interventricular delays. Based on morphology characteristics, ERs were classified manually for capture and failure to capture, and the validity of the classification was assessed by reference to the ECG. A total of 3,401 LV- and 3,345 RV-paced events were examined. In the RV and LV, the sensitivities of the algorithm were 95.6% and 96.1% in the RV and LV, respectively, and the corresponding specificities were 91.4% and 95.2%, respectively. The lower sensitivity in the RV was attributed to signal blanking in both channels during BiV pacing with a nonzero interventricular delay. The analysis revealed that the algorithm for identifying capture and failure to capture based on the ER-signal morphology was safe and effective in each ventricle with all leads tested in the study.

  18. Biventricular pacing preserves left ventricular performance in patients with high-grade atrio-ventricular block: a randomized comparison with DDD(R) pacing in 50 consecutive patients.

    PubMed

    Albertsen, Andi E; Nielsen, Jens C; Poulsen, Steen H; Mortensen, Peter T; Pedersen, Anders K; Hansen, Peter S; Jensen, Henrik K; Egeblad, Henrik

    2008-03-01

    We aimed to investigate whether biventricular (BiV) pacing minimizes left ventricular (LV) dyssynchrony and preserves LV ejection fraction (LVEF) as compared with standard dual-chamber DDD(R) pacing in consecutive patients with high-grade atrio-ventricular (AV) block. Fifty patients were randomized to DDD(R) pacing or BiV pacing. LVEF was measured using three-dimensional echocardiography. Tissue-Doppler imaging was used to quantify LV dyssynchrony in terms of number of segments with delayed longitudinal contraction (DLC). LVEF was not different between groups after 12 months (P = 0.18). In the DDD(R) group LVEF decreased significantly from 59.7(57.4-61.4)% at baseline to 57.2(52.1-60.6)% at 12 months of follow-up (P = 0.03), whereas LVEF remained unchanged in the BiV group [58.9(47.1-61.7)% at baseline vs. 60.1(55.2-63.3)% after 12 months (P = 0.15)]. Dyssynchrony was more prominent in the DDD(R) group than in the BiV group at baseline (2.2 +/- 2.2 vs. 1.4 +/- 1.3 segments with DLC per patient, P = 0.10); and at 12 month follow-up (1.8 +/- 1.9 vs. 0.8 +/- 0.9 segments with DLC per patient, P = 0.02). NT-proBNP was unchanged in the DDD(R) group during follow-up (122 +/- 178 pmol/L vs. 91 +/- 166 pmol/L, NS) but decreased significantly in the BiV-group (from 198 +/- 505 pmol/L to 86 +/- 95 pmol/L after 12 months, P = 0.02). BiV pacing minimizes LV dyssynchrony, preserves LV function, and reduces NT-proBNP in contrast to DDD(R) pacing in patients with high-grade AV block.

  19. Physiologic pacing: new modalities and pacing sites.

    PubMed

    Padeletti, Luigi; Lieberman, Randy; Valsecchi, Sergio; Hettrick, Douglas A

    2006-12-01

    Right ventricular (RV) apical pacing impairs left ventricular function by inducing dys-synchronous contraction and relaxation. Chronic RV apical pacing is associated with an increased risk of atrial fibrillation, morbidity, and even mortality. These observations have raised questions regarding the appropriate pacing mode and site, leading to the introduction of algorithms and new pacing modes to reduce the ventricular pacing burden in dual chamber devices, and a shift of the pacing site away from the RV apex. However, further investigations are required to assess the long-term results of pacing from alternative sites in the right ventricle, because long-term results so far are equivocal. The potential benefit of prophylactic biventricular, mono-chamber left ventricular, and bifocal RV pacing should be explored in selected patients with a narrow QRS complex, especially those with impaired left ventricular function. His bundle pacing is a promising and evolving technique that requires improvements in lead technology.

  20. Recent advances in pacemaker and implantable defibrillator therapy for young patients.

    PubMed

    Walsh, Edward P; Cecchin, Frank

    2004-03-01

    This review is intended to highlight major clinical advances over the past year related to (1). biventricular pacing as a treatment for dilated myopathy, (2). growing clinical experience with implantable cardioverter defibrillators in pediatrics, (3). technical advances in standard antibradycardia pacing, and (4). an appraisal of the newly updated ACC/AHA/NASPE guidelines for device implant in children and adolescents. Complex rhythm devices are being used more frequently in children. Biventricular pacing to improve ventricular contractility is a rapidly evolving technology that has now been applied to children and young adults with intraventricular conduction delay, such as bundle branch block after cardiac surgery. Implantable defibrillators are also being used for an expanding list of conditions, although lead dysfunction is seen as a fairly common complication in active young patients. Guidelines for device implantation have been developed, but the weight of evidence remains somewhat limited by the paucity of pediatric data in this field. Thanks to refinements in lead design and generator technology, coupled with rapidly expanding clinical indications, pacemakers and implantable defibrillators have become increasingly important components of cardiac therapy for young patients. Expanded multicenter clinical studies will be needed to develop more objective guidelines for use of this advanced technology.

  1. Optimal pacing modes after cardiac transplantation: is synchronisation of recipient and donor atria beneficial?

    PubMed Central

    Parry, Gareth; Malbut, Katie; Dark, John H; Bexton, Rodney S

    1992-01-01

    Objective—To investigate the response of the transplanted heart to different pacing modes and to synchronisation of the recipient and donor atria in terms of cardiac output at rest. Design—Doppler derived cardiac output measurements at three pacing rates (90/min, 110/min and 130/min) in five pacing modes: right ventricular pacing, donor atrial pacing, recipient-donor synchronous pacing, donor atrial-ventricular sequential pacing, and synchronous recipient-donor atrial-ventricular sequential pacing. Patients—11 healthy cardiac transplant recipients with three pairs of epicardial leads inserted at transplantation. Results—Donor atrial pacing (+11% overall) and donor atrial-ventricular sequential pacing (+8% overall) were significantly better than right ventricular pacing (p < 0·001) at all pacing rates. Synchronised pacing of recipient and donor atrial segments did not confer additional benefit in either atrial or atrial-ventricular sequential modes of pacing in terms of cardiac output at rest at these fixed rates. Conclusions—Atrial pacing or atrial-ventricular sequential pacing appear to be appropriate modes in cardiac transplant recipients. Synchronisation of recipient and donor atrial segments in this study produced no additional benefit. Chronotropic competence in these patients may, however, result in improved exercise capacity and deserves further investigation. PMID:1389737

  2. Recommendations for pacemaker implantation for the treatment of atrial tachyarrhythmias and resynchronisation therapy for heart failure: A report from the task force on pacemaker indications of the Dutch Working Group on Cardiac Pacing.

    PubMed

    van Hemel, N M; Dijkman, B; de Voogt, W G; Beukema, W P; Bosker, H A; de Cock, C C; Jordaens, L J L M; van Gelder, I C; van Gelder, L M; van Mechelen, R; Ruiter, J H; Sedney, M I; Slegers, L C

    2004-01-01

    Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively.

  3. Recommendations for pacemaker implantation for the treatment of atrial tachyarrhythmias and resynchronisation therapy for heart failure

    PubMed Central

    van Hemel, N.M.; Dijkman, B.; de Voogt, W.G.; Beukema, W.P.; Bosker, H.A.; de Cock, C.C.; Jordaens, L.J.L.M.; van Gelder, I.C.; van Gelder, L.M.; van Mechelen, R.; Ruiter, J.H.; Sedney, M.I.; Slegers, L.C.

    2004-01-01

    Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively. PMID:25696255

  4. Exercise capacity and N-terminal pro-brain natriuretic peptide levels with biventricular vs. right ventricular pacing for atrioventricular block: results from the PREVENT-HF German Substudy.

    PubMed

    Stockburger, Martin; de Teresa, Eduardo; Lamas, Gervasio; Desaga, Martin; Koenig, Carsten; Habedank, Dirk; Cobo, Erik; Navarro, Xavier; Wiegand, Uwe

    2014-01-01

    Previous studies showed unfavourable effects of right ventricular (RV) pacing. Ventricular pacing (VP), however, is required in many patients with atrioventricular (AV) block. The PREVENT-HF study explored left ventricular (LV) remodelling during RV vs. biventricular (BIV) pacing in AV block without advanced heart failure. The pre-specified PREVENT-HF German Substudy examined exercise capacity and N-terminal pro-brain natriuretic peptide (NT-proBNP). Patients with expected VP ≥80% were randomized to RV or BIV pacing. Endpoints were peak oxygen uptake (pVO2), oxygen uptake at the anaerobic threshold (VO2AT), ventilatory efficiency (VE/VCO2), and logNT-proBNP. Considering crossover, intention to treat (ITT), and on-treatment (OT) analyses of covariance (ANCOVA) were performed. For exercise testing 44 (RV: 25, BIV: 19), and for NT-proBNP 53 patients (RV: 29, BIV: 24) were included. The ITT analysis revealed significant differences in pVO2 [ANCOVA effect 2.83 mL/kg/min, confidence interval (CI) 0.83-4.91, P = 0.007], VO2AT (ANCOVA effect 2.14 mL/min/k, CI 0.14-4.15, P = 0.03), and VE/VCO2 (ANCOVA effect -5.46, CI -10.79 to -0.13, P = 0.04) favouring BIV randomization. The significant advantage in pVO2 persisted in OT analysis, while VO2AT and VE/VCO2 showed trends favouring BIV pacing. LogNT-proBNP did not differ between groups. (ITT: ANCOVA effect 0.008, CI -0.40 to +0.41, P = 0.97; OT: ANCOVA effect -0.03, CI -0.44 to 0.30, P = 0.90). Our study suggests that BIV pacing produces better exercise capacity over 1 year compared with RV pacing in patients without advanced heart failure and AV block. In contrast, we observed no significant changes of NT-proBNP. Larger trials will allow appraising the clinical usefulness of BIV pacing in AV block. ClinicalTrials.gov Identifier: NCT00170326.

  5. Acute hemodynamic effects of right and left ventricular lead positions during the implantation of cardiac resynchronization therapy defibrillators.

    PubMed

    Stockinger, Jochem; Staier, Klaus; Schiebeling-Römer, Jochen; Keyl, Cornelius

    2011-11-01

    To evaluate the acute hemodynamic effects of different right (RV) and left ventricular (LV) pacing sites in patients undergoing the implantation of a cardiac resynchronization therapy defibrillator (CRT-D). Stroke volume index (SVI), assessed via pulse contour analysis, and dp/dt max, obtained in the abdominal aorta, were analyzed in 21 patients with New York Heart Association class III heart failure and left bundle branch block (mean ejection fraction of 24 ± 6%), scheduled for CRT-D implantation under general anesthesia. We compared the hemodynamic effects of RV apical (A), RV septal (B), and biventricular pacing using the worst (lowest SVI; C) and best (highest SVI; D) coronary sinus lead positions. Mean arterial pressure, SVI, and dp/dt max did not differ significantly between RV apical and septal pacing. Dp/dt max and SVI increased significantly during biventricular pacing (dp/dt max: B, 588 ± 160 mmHg/s; C, 651 ± 218 mmHg/s, P = 0.03 vs B; D, 690 ± 220 mmHg/s, P = 0.02 vs C; SVI: B, 33.6 ± 5.5 mL/m², C, 34.8 ± 6.1 mL/m², P = 0.08 vs B, D 36.0 ± 6.0 mL/m², P < 0.001 vs C). The best hemodynamic response was associated with lateral or inferior lead positions in 15 patients. Other LV lead positions were most effective in six patients. The optimal LV lead position varies significantly among patients and should be individually determined during CRT-D implantation. The impact of the RV stimulation site in patients with intraventricular conduction delay, undergoing CRT-D implantation, has to be investigated in further studies.

  6. Efficiency of timing delays and electrode positions in optimization of biventricular pacing: a simulation study.

    PubMed

    Miri, Raz; Graf, Iulia M; Dössel, Olaf

    2009-11-01

    Electrode positions and timing delays influence the efficacy of biventricular pacing (BVP). Accordingly, this study focuses on BVP optimization, using a detailed 3-D electrophysiological model of the human heart, which is adapted to patient-specific anatomy and pathophysiology. The research is effectuated on ten heart models with left bundle branch block and myocardial infarction derived from magnetic resonance and computed tomography data. Cardiac electrical activity is simulated with the ten Tusscher cell model and adaptive cellular automaton at physiological and pathological conduction levels. The optimization methods are based on a comparison between the electrical response of the healthy and diseased heart models, measured in terms of root mean square error (E(RMS)) of the excitation front and the QRS duration error (E(QRS)). Intra- and intermethod associations of the pacing electrodes and timing delays variables were analyzed with statistical methods, i.e., t -test for dependent data, one-way analysis of variance for electrode pairs, and Pearson model for equivalent parameters from the two optimization methods. The results indicate that lateral the left ventricle and the upper or middle septal area are frequently (60% of cases) the optimal positions of the left and right electrodes, respectively. Statistical analysis proves that the two optimization methods are in good agreement. In conclusion, a noninvasive preoperative BVP optimization strategy based on computer simulations can be used to identify the most beneficial patient-specific electrode configuration and timing delays.

  7. Universal algorithm for diagnosis of biventricular capture in patients with cardiac resynchronization therapy.

    PubMed

    Jastrzebski, Marek; Kukla, Piotr; Fijorek, Kamil; Czarnecka, Danuta

    2014-08-01

    An accurate and universal method for diagnosis of biventricular (BiV) capture using a standard 12-lead electrocardiogram (ECG) would be useful for assessment of cardiac resynchronization therapy (CRT) patients. Our objective was to develop and validate such an ECG method for BiV capture diagnosis that would be independent of pacing lead positions-a major confounder that significantly influences the morphologies of paced QRS complexes. On the basis of an evaluation of 789 ECGs of 443 patients with heart failure and various right ventricular (RV) and left ventricular (LV) lead positions, the following algorithm was constructed and validated. BiV capture was diagnosed if the QRS in lead I was predominantly negative and either V1 QRS was predominantly positive or V6 QRS was of negative onset and predominantly negative (step 1), or if QRS complex duration was <160 ms (step 2). All other ECGs were classified as loss of LV capture. The algorithm showed good accuracy (93%), sensitivity (97%), and specificity (90%) for detection of loss of LV capture. The performance of the algorithm did not differ among apical, midseptal, and outflow tract RV lead positions and various LV lead positions. LV capture leaves diagnostic hallmarks in the fused BiV QRS related to different vectors of depolarization and more rapid depolarization of the ventricles. An accurate two-step ECG algorithm for BiV capture diagnosis was developed and validated. This algorithm is universally applicable to all CRT patients, regardless of the positions of the pacing leads. ©2014 Wiley Periodicals, Inc.

  8. Indications for permanent pacing and pacing mode prescription from 1989 to 2006. Experience of a single academic centre in Northern Greece.

    PubMed

    Styliadis, Ioannis H; Mantziari, Aggeliki P; Gouzoumas, Nikolaos I; Vassilikos, Vasilios P; Paraskevaidis, Stelios A; Mochlas, Sotirios T; Boufidou, Amalia I; Parcharidis, Georgios E

    2008-01-01

    Indications for pacing and pacing mode prescription have changed in the past decades following advances in pacemaker technology. The aim of the present study was to evaluate changes in indications for pacing and pacing modes during the years 1989-2006 in a single academic pacemaker centre in Northern Greece. Archives of permanent pacemaker implantation procedures were studied retrospectively and data from all implants, first or replacements, were retrieved. Data from 2078 procedures were found, 78.7% of which were first implantations. Patients were 54% male with mean age 72.5 years. Main indications for pacing were atrioventricular block (AVB, 45.7%), sick sinus syndrome (SSS, 32.8%), and atrial fibrillation (12.1%). Almost half (48.9%) of the AVB cases were complete AVB, while the most common types of SSS were tachy-brady syndrome (44.1%) and asystole (27.1%). Rare indications for pacing were carotid sinus syndrome (5.0%), heart failure (3.3%) and hypertrophic obstructive cardiomyopathy (1.0%). The two most frequently used pacing modes were VVI (38.5%) and DDD (25.8%). However, pacing modes have changed greatly over the years, with a marked increase in dual-chamber pacing after 1997 and a preference for rate responsive units after 2002. Biventricular systems were also used in selected patients with heart failure from 2002 on. Indications for pacing and pacing mode prescription in our centre are similar to other pacemaker registries and reflect the global trend in pacing for mimicking the physiological activity of the heart and for addressing problems other than symptomatic bradycardia.

  9. Effects of simultaneous and optimized sequential cardiac resynchronization therapy on myocardial oxidative metabolism and efficiency.

    PubMed

    Christenson, Stuart D; Chareonthaitawee, Panithaya; Burnes, John E; Hill, Michael R S; Kemp, Brad J; Khandheria, Bijoy K; Hayes, David L; Gibbons, Raymond J

    2008-02-01

    Cardiac resynchronization therapy (CRT) can improve left ventricular (LV) hemodynamics and function. Recent data suggest the energy cost of such improvement is favorable. The effects of sequential CRT on myocardial oxidative metabolism (MVO(2)) and efficiency have not been previously assessed. Eight patients with NYHA class III heart failure were studied 196 +/- 180 days after CRT implant. Dynamic [(11)C]acetate positron emission tomography (PET) and echocardiography were performed after 1 hour of: 1) AAI pacing, 2) simultaneous CRT, and 3) sequential CRT. MVO(2) was calculated using the monoexponential clearance rate of [(11)C]acetate (k(mono)). Myocardial efficiency was expressed in terms of the work metabolic index (WMI). P values represent overall significance from repeated measures analysis. Global LV and right ventricular (RV) MVO(2) were not significantly different between pacing modes, but the septal/lateral MVO(2) ratio differed significantly with the change in pacing mode (AAI pacing = 0.696 +/- 0.094 min(-1), simultaneous CRT = 0.975 +/- 0.143 min(-1), and sequential CRT = 0.938 +/- 0.189 min(-1); overall P = 0.001). Stroke volume index (SVI) (AAI pacing = 26.7 +/- 10.4 mL/m(2), simultaneous CRT = 30.6 +/- 11.2 mL/m(2), sequential CRT = 33.5 +/- 12.2 mL/m(2); overall P < 0.001) and WMI (AAI pacing = 3.29 +/- 1.34 mmHg*mL/m(2)*10(6), simultaneous CRT = 4.29 +/- 1.72 mmHg*mL/m(2)*10(6), sequential CRT = 4.79 +/- 1.92 mmHg*mL/m(2)*10(6); overall P = 0.002) also differed between pacing modes. Compared with simultaneous CRT, additional changes in septal/lateral MVO(2), SVI, and WMI with sequential CRT were not statistically significant on post hoc analysis. In this small selected population, CRT increases LV SVI without increasing MVO(2), resulting in improved myocardial efficiency. Additional improvements in LV work, oxidative metabolism, and efficiency from simultaneous to sequential CRT were not significant.

  10. Complex Biventricular Pacing - A Case Series

    PubMed Central

    Hodkinson, Emily Catherine; Morrice, Keith; Loan, William; Nicholas, Jacob; Chew, EngWooi

    2014-01-01

    It is established that cardiac resynchronisation therapy (CRT) reduces mortality and hospitalisation and improves functional class in patients with NYHA class 3-4 heart failure, an ejection fraction of ≤ 35% and a QRS duration of ≥ 120ms. Recent updates in the American guidelines have expanded the demographic of patients in whom CRT may be appropriate. Here we present two cases of complex CRT; one with a conventional indication but occluded central veins and the second with a novel indication for CRT post cardiac transplant. PMID:24493915

  11. Right atrial pacing impairs cardiac function during resynchronization therapy: acute effects of DDD pacing compared to VDD pacing.

    PubMed

    Bernheim, Alain; Ammann, Peter; Sticherling, Christian; Burger, Peter; Schaer, Beat; Brunner-La Rocca, Hans Peter; Eckstein, Jens; Kiencke, Stephanie; Kaiser, Christoph; Linka, Andre; Buser, Peter; Pfisterer, Matthias; Osswald, Stefan

    2005-05-03

    We aimed to compare the hemodynamic effects of right-atrial-paced (DDD) and right-atrial-sensed (VDD) biventricular paced rhythm on cardiac resynchronization therapy (CRT). Cardiac resynchronization therapy improves hemodynamics in patients with severe heart failure and left ventricular (LV) dyssynchrony. However, the impact of active right atrial pacing on resynchronization therapy is unknown. Seventeen CRT patients were studied 10 months (range: 1 to 46 months) after implantation. At baseline, the programmed atrioventricular delay was optimized by timing LV contraction properly at the end of atrial contraction. In both modes the acute hemodynamic effects were assessed by multiple Doppler echocardiographic parameters. Compared to DDD pacing, VDD pacing resulted in much better improvement of intraventricular dyssynchrony assessed by the septal-to-posterior wall motion delay (VDD 106 +/- 83 ms vs. DDD 145 +/- 95 ms; p = 0.001), whereas the interventricular mechanical delay (difference between onset of pulmonary and aortic outflow) did not differ (VDD 20 +/- 21 ms vs. DDD 18 +/- 17 ms; p = NS). Furthermore, VDD pacing significantly prolonged the rate-corrected LV filling period (VDD 458 +/- 123 ms vs. DDD 371 +/- 94 ms; p = 0.0001) and improved the myocardial performance index (VDD 0.60 +/- 0.18 vs. DDD 0.71 +/- 0.23; p < 0.01). Our findings suggest that avoidance of right atrial pacing results in a higher degree of LV resynchronization, in a substantial prolongation of the LV filling period, and in an improved myocardial performance. Thus, the VDD mode seems to be superior to the DDD mode in CRT patients.

  12. Sensors for rate responsive pacing

    PubMed Central

    Dell'Orto, Simonetta; Valli, Paolo; Greco, Enrico Maria

    2004-01-01

    Advances in pacemaker technology in the 1980s have generated a wide variety of complex multiprogrammable pacemakers and pacing modes. The aim of the present review is to address the different rate responsive pacing modalities presently available in respect to physiological situations and pathological conditions. Rate adaptive pacing has been shown to improve exercise capacity in patients with chronotropic incompetence. A number of activity and metabolic sensors have been proposed and used for rate control. However, all sensors used to optimize pacing rate metabolic demands show typical limitations. To overcome these weaknesses the use of two sensors has been proposed. Indeed an unspecific but fast reacting sensor is combined with a more specific but slower metabolic one. Clinical studies have demonstrated that this methodology is suitable to reproduce normal sinus behavior during different types and loads of exercise. Sensor combinations require adequate sensor blending and cross checking possibly controlled by automatic algorithms for sensors optimization and simplicity of programming. Assessment and possibly deactivation of some automatic functions should be also possible to maximize benefits from the dual sensor system in particular conditions. This is of special relevance in patient whose myocardial contractility is limited such as in subjects with implantable defibrillators and biventricular pacemakers. The concept of closed loop pacing, implementing a negative feedback relating pacing rate and the control signal, will provide new opportunities to optimize dual-sensors system and deserves further investigation. The integration of rate adaptive pacing into defibrillators is the natural consequence of technical evolution. PMID:16943981

  13. Natural history and outcome of aortic stenosis diagnosed prenatally.

    PubMed Central

    Simpson, J. M.; Sharland, G. K.

    1997-01-01

    OBJECTIVE: To document the growth of the left heart structures and outcome of fetuses with aortic stenosis. DESIGN: Retrospective echocardiographic and clinical study. SETTING: Tertiary centre for fetal cardiology. PATIENTS: 27 consecutive fetuses with aortic stenosis. MAIN OUTCOME MEASURES: Survival of affected fetuses. Measurement of left ventricular end diastolic volume (LVEDV), aortic root diameter, and ejection fraction. RESULTS: Before 25 weeks' gestation, the LVEDV was normal or increased in all cases. In six of eight fetuses studied sequentially, the LVEDV fell across normal centiles. Initial ejection fraction was reduced in 23 fetuses (88%). Before 28 weeks' gestation, the aortic root was normal in all but one case, but after 29 weeks, 11 of 13 fetuses had values below the 50th centile. In two fetuses prenatal aortic valvoplasty was attempted, 10 babies had postnatal interventions, and there were six survivors. Biventricular repair was attempted in eight cases, of whom five survived. A first stage Norwood operation was performed in three babies, of whom one survived. The four fetuses with the highest aortic root z scores had successful biventricular repair. The two fetuses with initially normal ejection fractions survived. Successful biventricular repair was achieved even where the LVEDV was below the 5th centile. CONCLUSIONS: In aortic stenosis diagnosed prenatally, failure of growth of the left ventricle and aortic root often occurs. The outcome of affected fetuses is better than previously reported. Prenatal echocardiography may assist selection of suitable candidates for biventricular versus Norwood repair. Images PMID:9093035

  14. Influence of automatic frequent pace-timing adjustments on effective left ventricular pacing during cardiac resynchronization therapy.

    PubMed

    Varma, Niraj; Stadler, Robert W; Ghosh, Subham; Kloppe, Axel

    2017-05-01

    Cardiac resynchronization therapy (CRT) requires effective left ventricular (LV) pacing (i.e. sufficient energy and appropriate timing to capture). The AdaptivCRT™ (aCRT) algorithm serves to maintain ventricular fusion during LV or biventricular pacing. This function was tested by comparing the morphological consistency of ventricular depolarizations and percentage effective LV pacing in CRT patients randomized to aCRT vs. echo-optimization. Continuous recordings (≥20 h) of unipolar LV electrograms from aCRT (n = 38) and echo-optimized patients (n = 22) were analysed. Morphological consistency was determined by the correlation coefficient between each beat and a template beat. Effective LV pacing of paced beats was assessed by algorithmic analysis of negative initial EGM deflection in each evoked response. The %CRT pacing delivered, %effective LV pacing (i.e. % of paced beats with effective LV pacing), and overall %effective CRT (i.e. product of %CRT pacing and %effective LV pacing) were compared between aCRT and echo-optimized patients. Demographics were similar between groups. The mean correlation coefficient between individual beats and template was greater for aCRT (0.96 ± 0.03 vs. 0.91 ± 0.13, P = 0.07). Although %CRT pacing was similar for aCRT and echo-optimized (median 97.4 vs. 98.6%, P = 0.14), %effective LV pacing was larger for aCRT [99.6%, (99.1%, 99.9%) vs. 94.3%, (24.3%, 99.8%), P=0.03]. For aCRT vs. echo-optimized groups, the proportions of patients with ≥90% effective LV pacing was 92 vs. 55% (P = 0.002), and with ≥90% effective CRT was 79 vs. 45%, respectively (P = 0.018). AdaptivCRT™ significantly increased effective LV pacing over echo-optimized CRT. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  15. Assessment of hemodynamic load components affecting optimization of cardiac resynchronization therapy by lumped parameter mode.

    PubMed

    Xu, Ke; Butlin, Mark; Avolio, Alberto P

    2012-01-01

    Timing of biventricular pacing devices employed in cardiac resynchronization therapy (CRT) is a critical determinant of efficacy of the procedure. Optimization is done by maximizing function in terms of arterial pressure (BP) or cardiac output (CO). However, BP and CO are also determined by the hemodynamic load of the pulmonary and systemic vasculature. This study aims to use a lumped parameter circulatory model to assess the influence of the arterial load on the atrio-ventricular (AV) and inter-ventricular (VV) delay for optimal CRT performance.

  16. [Influence of pacing site on myocardial transmural dispersion of repolarization in intact normal and dilated cardiomyopathy dogs].

    PubMed

    Bai, Rong; Pu, Jun; Liu, Nian; Lu, Jia-Gao; Zhou, Qiang; Ruan, Yan-Fei; Niu, Hui-Yan; Wang, Lin

    2003-12-25

    In order to verify the hypothesis that left ventricular epicardial (LV-Epi) pacing and biventricular (BiV) pacing unavoidably influence the myocardial electrophysiological characters and may result in high risk of malignant ventricular arrhythmia, we calculated, in both normal mongrel dogs and dog models with rapid-right-ventricular-pacing induced dilated cardiomyopathy congestive heart failure (DCM-CHF), the monophasic action potential duration (MAPD) and the transmural dispersion of repolarization (TDR) in intracardiac electrogram together with the QT interval and T(peak)-T(end) (T(p(-T(e)) interval in surface electrocardiogram (ECG) during LV-Epi and BiV pacing, compared with those during right ventricular endocardial (RV-Endo) pacing. To prepare the DCM-CHF dog model, rapid right ventricular pacing (250 bpm) was performed for 23.6+/-2.57 days to the dog. All the normal and DCM-CHF dogs were given radio frequency catheter ablation (RFCA) to His bundle with the guide of X-ray fluoroscopy. After the RFCA procedures, the animals were under the situation of complete atrioventricular block so that the canine heart rates could be voluntarily controlled in the following experiments. After a thoracotomy, ECG and monophasic action potentials (MAP) of subendocardial, subepicardial and mid-layer myocardium were recorded synchronously in 8 normal and 5 DCM-CHF dogs during pacing from endocardium of RV apex (RV-Endo), epicardium of LV anterior wall (LV-Epi) and simultaneously both of the above (biventricular, BiV), the later was similar to the ventricular resynchronization therapy to congestive heart failure patients in clinic. The Tp-Te) meant the interval from the peak to the end of T wave, which was a representative index of TDR in surface ECG. The TDR was defined as the difference between the longest and the shortest MAPD of subendocardial, subepicardial and mid-layer myocardium. Our results showed that in normal dogs, pacing participating of LV (LV-Epi, BiV) prolonged MAPD of all the three layers of the myocardium (P<0.05) with the character that mid-layer MAPD was the longest and subepicardial MAPD was the shortest following subendocardial MAPD. At the same time, TDR prolonged from 26.75 ms at RV-Endo pacing to 37.54 ms at BiV pacing and to 47.16 ms at LV-Epi pacing (P<0.001). Meanwhile in surface ECG, BiV and LV-Epi pacing resulted in a longer Tp-Te) interval compared with RV-Endo pacing (P<0.01), without parallel QT interval prolongation. Furthermore, all the DCM-CHF model dogs showed manifestations of congestive heart failure and enlargement of left ventricles. Based on the lengthening of mid-layer MAPD from 257.35 ms to 276.30 ms (P<0.0001) and increase of TDR from 27.58 ms to 33.80 ms (P equals;0.002) in DCM-CHF model due to the structural disorders of myocardium compared with the normal dog, LV-Epi and BiV pacing also led to the effect of prolonging MAPD of three layers of the myocardium and enlarging TDR. From these results we make the conclusions that prolongation of MAPD of subendocardial, subepicardial and mid-layer myocardium and increase in TDR during pacing participating of LV (LV-Epi, BiV) may contribute to the formation of unidirectional block and reentry, which play roles or at least are the high risk factors in the development of malignant ventricular arrhythmia, especially in case of structural disorders of myocardium. These findings must be considered seriously when ventricular resynchronization therapy is performed to congestive heart failure patients.

  17. Triple-site pacing for cardiac resynchronization in permanent atrial fibrillation - Acute phase results from a prospective observational study.

    PubMed

    Marques, Pedro; Nobre Menezes, Miguel; Lima da Silva, Gustavo; Bernardes, Ana; Magalhães, Andreia; Cortez-Dias, Nuno; Carpinteiro, Luís; de Sousa, João; Pinto, Fausto J

    2016-06-01

    Multi-site pacing is emerging as a new method for improving response to cardiac resynchronization therapy (CRT), but has been little studied, especially in patients with atrial fibrillation. We aimed to assess the effects of triple-site (Tri-V) vs. biventricular (Bi-V) pacing on hemodynamics and QRS duration. This was a prospective observational study of patients with permanent atrial fibrillation and ejection fraction <40% undergoing CRT implantation (n=40). One right ventricular (RV) lead was implanted in the apex and another in the right ventricular outflow tract (RVOT) septal wall. A left ventricular (LV) lead was implanted in a conventional venous epicardial position. Cardiac output (using the FloTrac™ Vigileo™ system), mean QRS and ejection fraction were calculated. Mean cardiac output was 4.81±0.97 l/min with Tri-V, 4.68±0.94 l/min with RVOT septal and LV pacing, and 4.68±0.94 l/min with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV). Mean pre-implantation QRS was 170±25 ms, 123±18 ms with Tri-V, 141±25 ms with RVOT septal pacing and LV pacing and 145±19 with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV and pre-implantation). Mean ejection fraction was significantly higher with Tri-V (30±11%) vs. Bi-V pacing (28±12% with RVOT septal and LV pacing and 28±11 with RV apical and LV pacing) and pre-implantation (25±8%). Tri-V pacing produced higher cardiac output and shorter QRS duration than Bi-V pacing. This may have a significant impact on the future of CRT. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  18. Is there a right place to pace the right ventricle? Evaluation of apical and septal positions in a pacemaker population: study protocol for a prospective intervention-control trial.

    PubMed

    Muto, Carmine; Calvi, Valeria; Botto, Giovanni Luca; Pecora, Domenico; Ciaramitaro, Gianfranco; Valsecchi, Sergio; Malacrida, Maurizio; Maglia, Giampiero

    2014-11-01

    The main objective of research in pacemaker therapy has been to provide the best physiologic way to pace the heart. Despite the good results provided by right ventricular pacing minimization and by biventricular pacing in specific subsets of heart failure patients, these options present many limitations for standard pacemaker recipients. In these patients, pacing the right ventricle at alternative sites could result in a lower degree of left intraventricular dyssynchrony. Despite the lack of strong evidence and the difficulty in placing and accurately classifying the final lead position, pacing at alternative right ventricular sites seems to have become a standard procedure at many implanting centers. The RIGHT PACE study is a multi-center, prospective, single-blind, double-arm, intervention-control trial comparing right ventricular pacing from the apex and from the septal site in terms of left intraventricular dyssynchrony. A total of 408 patients with indications for cardiac pacing but without indications for ICD and/or CRT will be enrolled. Investigators will be divided on the basis of their prior experience of selective site pacing lead implantation and patients will be treated according to the clinical practice of the centers. After device implantation, they will be followed up for 24 months through evaluation of clinical, echocardiographic and safety/system-performance variables. This study might provide important information about the impact of the right ventricular pacing on the left ventricular dyssynchrony, and about acute and chronic responses to selective site pacing, as adopted in current clinical practice. This trial is registered at ClinicalTrials.gov (ID:NCT01647490). Right Ventricular Lead Placement in a Pacemaker Population: Evaluation of apical and alternative position. ClinicalTrials.gov: NCT01647490. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Alternative right ventricular pacing sites.

    PubMed

    Łuciuk, Dariusz; Łuciuk, Marek; Gajek, Jacek

    2015-01-01

    The main adverse effect of chronic stimulation is stimulation-induced heart failure in case of ventricular contraction dyssynchrony. Because of this fact, new techniques of stimulation should be considered to optimize electrotherapy. One of these methods is pacing from alternative right ventricular sites. The purpose of this article is to review currently accumulated data about alternative sites of cardiac pacing. Medline and PubMed bases were used to search English and Polish reports published recently. Recent studies report a deleterious effect of long term apical pacing. It is suggested that permanent apical stimulation, by omitting physiological conduction pattern with His-Purkinie network, may lead to electrical and mechanical dyssynchrony of heart muscle contraction. In the long term this pathological situation can lead to severe heart failure and death. Because of this, scientists began to search for some alternative sites of cardiac pacing to reduce the deleterious effect of stimulation. Based on current accumulated data, it is suggested that the right ventricular outflow tract, right ventricular septum, direct His-bundle or biventricular pacing are better alternatives due to more physiological electrical impulse propagation within the heart and the reduction of the dyssynchrony effect. These methods should preserve a better left ventricular function and prevent the development of heart failure in permanent paced patients. As there is still not enough, long-term, randomized, prospective, cross-over and multicenter studies, further research is required to validate the benefits of using this kind of therapy. The article should pay attention to new sites of cardiac stimulation as a better and safer method of treatment.

  20. Predictors of Total Mortality and Echocardiographic Response for Cardiac Resynchronization Therapy: A Cohort Study

    PubMed Central

    Gazzoni, Guilherme Ferreira; Fraga, Matheus Bom; Ferrari, Andres Di Leoni; Soliz, Pablo da Costa; Borges, Anibal Pires; Bartholomay, Eduardo; Kalil, Carlos Antonio Abunader; Giaretta, Vanessa; Rohde, Luis Eduardo Paim

    2017-01-01

    Background Clinical studies demonstrate that up to 40% of patients do not respond to cardiac resynchronization therapy (CRT), thus, appropriate patient selection is critical to the success of CRT in heart failure. Objective Evaluation of mortality predictors and response to CRT in the Brazilian scenario. Methods Retrospective cohort study including patients submitted to CRT in a tertiary hospital in southern Brazil from 2008 to 2014. Survival was assessed through a database of the State Department of Health (RS). Predictors of echocardiographic response were evaluated using Poisson regression. Survival analysis was performed by Cox regression and Kaplan Meyer curves. A two-tailed p value less than 0.05 was considered statistically significant. Results A total of 170 patients with an average follow-up of 1011 ± 632 days were included. The total mortality was 30%. The independent predictors of mortality were age (hazard ratio [HR] of 1.05, p = 0.027), previous acute myocardial infarction (AMI) (HR of 2.17, p = 0.049) and chronic obstructive pulmonary disease (COPD) (HR of 3.13, p = 0.015). The percentage of biventricular stimulation at 6 months was identified as protective factor of mortality ([HR] 0.97, p = 0.048). The independent predictors associated with the echocardiographic response were absence of mitral insufficiency, presence of left bundle branch block and percentage of biventricular stimulation. Conclusion Mortality in patients submitted to CRT in a tertiary hospital was independently associated with age, presence of COPD and previous AMI. The percentage of biventricular pacing evaluated 6 months after resynchronizer implantation was independently associated with improved survival and echocardiographic response. PMID:29185615

  1. The Post-Myocardial Infarction Pacing Remodeling Prevention Therapy (PRomPT) Trial: Design and Rationale.

    PubMed

    Chung, Eugene S; Fischer, Trent M; Kueffer, Fred; Anand, Inder S; Bax, Jeroen J; Gold, Michael R; Gorman, Robert C; Theres, Heinz; Udelson, James E; Stancak, Branislav; Svendsen, Jesper H; Stone, Gregg W; Leon, Angel

    2015-07-01

    Despite considerable improvements in the medical management of patients with myocardial infarction (MI), patients with large MI still have substantial risk of developing heart failure. In the early post-MI setting, implantable cardioverter defibrillators have reduced arrhythmic deaths but have no impact on overall mortality. Therefore, additional interventions are required to further reduce the overall morbidity and mortality of patients with large MI. The Pacing Remodeling Prevention Therapy (PRomPT) trial is designed to study the effects of peri-infarct pacing in preventing adverse post-MI remodeling. Up to 120 subjects with peak creatine phosphokinase >3,000 U/L (or troponin T >10 μg/L) at time of MI will be randomized to either dual-site or single-site biventricular pacing with the left ventricular lead implanted in a peri-infarct region or to a nonimplanted control group. Those randomized to a device will be blinded to the pacing mode, but randomization to a device or control cannot be blinded. Subjects randomized to pacing will have the device implanted within 10 days of MI. The primary objective is to assess the change in left ventricular end-diastolic volume from baseline to 18 months. Secondary objectives are to assess changes in clinical and mechanistic parameters between the groups, including rates of hospitalization for heart failure and cardiovascular events, the incidence of sudden cardiac death and all-cause mortality, New York Heart Association functional class, 6-minute walking distance, and quality of life. The PRomPT trial will provide important evidence regarding the potential of peri-infarct pacing to interrupt adverse remodeling in patients with large MI. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. [Role of cyclic adenosine monophosphate response element binding protein in ventricular pacing induced cardiac electrical remodeling in a canine model].

    PubMed

    Chen, Xuesi; Chen, Xingxing; Cheng, Junhua; Hong, Jun; Zheng, Cheng; Zhao, Jinglin; Li, Jin; Lin, Jiafeng

    2015-04-01

    This project is designed to explore the potential role of cyclic adenosine monophosphate (cAMP) response element binding protein (CREB) in cardiac electrical remodeling induced by pacing at different ventricular positions in dogs. An animal model by implanting the pacemakers in beagles was established. According to the different pacing positions, the animals were divided into 4 groups:conditional control group (n=6), left ventricle pacing group (n=6), right ventricle pacing group (n=6) and bi-ventricle pacing group (n=6). Cardiac and electrical remodeling were observed by echocardiography, electrocardiogram and plasma BNP. Myocardial pathology and protein expression of extracellular regulated protein kinases1/2 (ERK1/2), P38 mitogen activated protein kinases (P38 MAPK) and CREB were examined at 4 weeks post pacing. Cardiac structure and plasma BNP level were similar among 4 groups (all P>0.05). Electrocardiogram derived Tp-Te interval was significantly prolonged post pacing (92±11, 91±10, and 79±13 ms vs. 60±12 ms), and the Tp-Te interval in bi-ventricle pacing group was shorter than in left or right ventricle pacing group (P < 0.05). Western blot results showed that the expression of p-ERK1/2 in left ventricular myocardium of left ventricle pacing group, right ventricular myocardium of right ventricle pacing group and bi-ventricular myocardium of bi-ventricle pacing group was 2.7±0.4, 2.4±0.2, 1.7±0.1 and 1.9±0.2, respectively, the expression of p-P38 MAPK was 1.9±0.3, 1.7±0.2, 0.8±0.1 and 1.1±0.1, respectively, and the expression of p-CREB was 2.1±0.2, 2.0±0.2, 2.7±0.4 and 2.6±0.3, respectively. The p-ERK1/2 and p-P38 MAPK expression of bi-ventricle pacing group was lower,but the p-CREB expression was higher compared to the other pacing groups (P < 0.05). Ventricular pacing could induce electrical remodeling evidenced by prolonged Tp-Te interval and increased phosphorylation of ERK1/2 and p38 MAPK and reduced phosphorylation of CREB. Compared with single ventricle pacing, bi-ventricle pacing could attenuate electrical remodeling in this model.

  3. Potential role of biventricular pacing beyond advanced systolic heart failure.

    PubMed

    Fang, Fang; Sanderson, John E; Yu, Cheuk-Man

    2013-01-01

    Cardiac resynchronization therapy (CRT) is an effective therapy for advanced heart failure (HF) patients. The indications are well defined in recent guidelines and broadly indicate that CRT is suitable for chronic HF patients with left ventricular ejection fraction (EF) ≤35% and in NYHA class III or IV (Class I), and those with prolonged QRS duration ≥120 ms with left bundle branch block (LBBB) QRS morphology, or QRS duration ≥150 ms irrespective of QRS morphology (Class IIa). For patients with NYHA class II symptoms, CRT is recommended for patients with EF ≤30% and QRS duration ≥130 ms with LBBB QRS morphology (Class I, level of evidence: A), or QRS duration ≥150 ms irrespective of QRS morphology (Class IIa, level of evidence: A). However, CRT may benefit additional patients outside these criteria. In this review, we summarize the role of CRT in some subgroups, including patients with mild and moderate HF, upgrading to CRT from right ventricular (RV) pacing, bradycardia patients with routine pacing indications, congenital heart disease and specific cardiomyopathies. It is possible that CRT can give symptomatic and mortality benefits in some of these subgroups in the future and further clinical trials are warranted.  

  4. The Myocardial Ischemia Evaluated by Real-Time Contrast Echocardiography May Predict the Response to Cardiac Resynchronization Therapy: A Large Animal Study

    PubMed Central

    Chen, Yongle; Cheng, Leilei; Yao, Haohua; Chen, Haiyan; Wang, Yongshi; Zhao, Weipeng; Pan, Cuizhen; Shu, Xianhong

    2014-01-01

    Evidence-based criteria for applying cardiac resynchronization therapy (CRT) in patients with ischemic cardiomyopathy are still scarce. The aim of the present study was to evaluate the predictive value of real-time myocardial contrast echocardiography (RT-MCE) in a preclinical canine model of ischemic cardiomyopathy who received CRT. Ischemic cardiomyopathy was produced by ligating the first diagonal branch in 20 beagles. Dogs were subsequently divided into two groups that were either treated with bi-ventricular pacing (CRT group) or left untreated (control group). RT-MCE was performed at baseline, before CRT, and 4 weeks after CRT. Two-dimensional speckle tracking imaging was used to evaluate the standard deviation of circumferential (Cir12SD), radial (R12SD), and longitudinal (L12SD) strains of left ventricular segments at basal as well as middle levels. Four weeks later, the Cir12SD, R12SD, and myocardial blood flow (MBF) of the treated group were significantly improved compared to their non-CRT counterparts. Furthermore, MBF values measured before CRT were significantly higher in responders than in non-responders to bi-ventricular pacing. Meanwhile, no significant differences were observed between the responder and non-responder groups in terms of Cir12SD, R12SD, and L12SD. A high degree of correlation was found between MBF values before CRT and LVEF after CRT. When MBF value>24.9 dB/s was defined as a cut-off point before CRT, the sensitivity and specificity of RT-MCE in predicting the response to CRT were 83.3% and 100%, respectively. Besides, MBF values increased significantly in the CRT group compared with the control group after 4 weeks of pacing (49.8±15.5 dB/s vs. 28.5±4.6 dB/s, p<0.05). Therefore, we considered that myocardial perfusion may be superior to standard metrics of LV synchrony in selecting appropriate candidates for CRT. In addition, CRT can improve myocardial perfusion in addition to cardiac synchrony, especially in the setting of ischemic cardiomyopathy. PMID:25469632

  5. Left ventricular epicardial activation increases transmural dispersion of repolarization in healthy, long QT, and dilated cardiomyopathy dogs.

    PubMed

    Bai, Rong; Lü, Jiagao; Pu, Jun; Liu, Nian; Zhou, Qiang; Ruan, Yanfei; Niu, Huiyan; Zhang, Cuntai; Wang, Lin; Kam, Ruth

    2005-10-01

    Benefits of cardiac resynchronization therapy (CRT) are well established. However, less is understood concerning its effects on myocardial repolarization and the potential proarrhythmic risk. Healthy dogs (n = 8) were compared to a long QT interval (LQT) model (n = 8, induced by cesium chloride, CsCl) and a dilated cardiomyopathy with congestive heart failure (DCM-CHF, induced by rapid ventricular pacing, n = 5). Monophasic action potential (MAP) recordings were obtained from the subendocardium, midmyocardium, subepicardium, and the transmural dispersion of repolarization (TDR) was calculated. The QT interval and the interval from the peak to the end of the T wave (T(p-e)) were measured. All these characteristics were compared during left ventricular epicardial (LV-Epi), right ventricular endocardial (RV-Endo), and biventricular (Bi-V) pacing. In healthy dogs, TDR prolonged to 37.54 ms for Bi-V pacing and to 47.16 ms for LV-Epi pacing as compared to 26.75 ms for RV-Endo pacing (P < 0.001), which was parallel to an augmentation in T(p-e) interval (Bi-V pacing, 64.29 ms; LV-Epi pacing, 57.89 ms; RV-Endo pacing, 50.29 ms; P < 0.01). During CsCl exposure, Bi-V and LV-Epi pacing prolonged MAPD, TDR, and T(p-e) interval as compared to RV-Endo pacing. The midmyocardial MAPD (276.30 ms vs 257.35 ms, P < 0.0001) and TDR (33.80 ms vs 27.58 ms, P=0.002) were significantly longer in DCM-CHF dogs than those in healthy dogs. LV-Epi and Bi-V pacing further prolonged the MAPD and TDR in this model. LV-Epi and Bi-V pacing result in prolongation of ventricular repolarization time, and increase of TDR accounted for a parallel augmentation of the T(p-e) interval, which provides evidence that T(p-e) interval accurately represents TDR. These effects are magnified in the LQT and DCM-CHF canine models in addition to their intrinsic transmural heterogeneity in the intact heart. This mechanism may contribute to the development of malignant ventricular arrhythmias, such as torsades de pointes (TdP) in congestive heart failure (CHF) patients treated with CRT.

  6. A Case of a Cardiac Resynchronization Therapy-Defibrillator Exhibiting a Lower and Alternately Variable Basic Rate.

    PubMed

    Iwazaki, Keigo; Kojima, Toshiya; Murasawa, Takahide; Yokota, Jun; Tanimoto, Hikaru; Matsuda, Jun; Fukuma, Nobuaki; Matsubara, Takumi; Shimizu, Yu; Oguri, Gaku; Hasumi, Eriko; Kubo, Hitoshi; Chang, Kyungho; Fujiu, Katsuhito; Komuro, Issei

    2018-05-30

    A cardiac resynchronization therapy defibrillator (CRT-D) (Medtronic Inc. Protecta XT) was implanted in a 67-year-old man who had cardiac sarcoidosis with extremely low cardiac function. He had ventricular tachycardia which was controlled by catheter ablation, medication and pacing. The programmed mode was DDI, lower rate was 90 beats/minute, paced AV delay was 150 ms, and the noncompetitive atrial pacing (NCAP) function was programmed as 300 ms.After his admission for pneumonia and heart failure, we changed his DDI mode to a DDD mode because he had atrial tachycardia, which led to inadequate bi-ventricular pacing. After a while, there were cycle lengths which were longer than his device setting and alternately varied. We were able to avoid this phenomenon with AV delay of 120 ms and NCAP of 200 ms.NCAP is an algorithm which creates a gap above a certain period after the detection of an atrial signal during the postventricular atrial refractory period of the pacemaker. This is to prevent atrial tachycardia and repetitive non-reentrant ventriculoatrial (VA) synchrony in the presence of retrograde VA conduction. But in this case, NCAP algorithm induced much lower rate than the programmed basic lower rate. This situation produced some arrhythmias and exacerbated symptoms of heart failure. This had to be paid attention to, especially when the device was programmed at high basic heart rate.

  7. The Relationship between Successful Completion and Sequential Movement in Self-Paced Distance Courses

    ERIC Educational Resources Information Center

    Lim, Janine M.

    2016-01-01

    A course design question for self-paced courses includes whether or not technological measures should be used in course design to force students to follow the sequence intended by the course author. This study examined learner behavior to understand whether the sequence of student assignment submissions in a self-paced distance course is related…

  8. Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay.

    PubMed

    Varma, Niraj; O'Donnell, David; Bassiouny, Mohammed; Ritter, Philippe; Pappone, Carlo; Mangual, Jan; Cantillon, Daniel; Badie, Nima; Thibault, Bernard; Wisnoskey, Brian

    2018-02-06

    QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. Seventy-five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128-300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration (QRSd) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+SyncAV with 50 ms offset (Mode II), BiV+SyncAV with offset that minimized QRSd (Mode III), or LV-only pacing+SyncAV with 50 ms offset (Mode IV). The intrinsic QRSd (162±16 ms) was reduced to 142±17 ms (-11.8%) by Mode I, 136±14 ms (-15.6%) by Mode IV, and 132±13 ms (-17.8%) by Mode II. Mode III yielded the shortest overall QRSd (123±12 ms, -23.9% [ P <0.001 versus all modes]) and was the only configuration without QRSd prolongation in any patient. QRS narrowing occurred regardless of QRSd, PR, or LV-paced intervals, or underlying ischemic disease. Post-implant electrical optimization in already well-selected patients with left bundle branch block and optimized LV lead position is facilitated by patient-tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device-based algorithm. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  9. Electrical latency predicts the optimal left ventricular endocardial pacing site: results from a multicentre international registry.

    PubMed

    Sieniewicz, Benjamin J; Behar, Jonathan M; Sohal, Manav; Gould, Justin; Claridge, Simon; Porter, Bradley; Niederer, Steve; Gamble, James H P; Betts, Tim R; Jais, Pierre; Derval, Nicolas; Spragg, David D; Steendijk, Paul; van Gelder, Berry M; Bracke, Frank A; Rinaldi, Christopher A

    2018-04-23

    The optimal site for biventricular endocardial (BIVENDO) pacing remains undefined. Acute haemodynamic response (AHR) is reproducible marker of left ventricular (LV) contractility, best expressed as the change in the maximum rate of LV pressure (LV-dp/dtmax), from a baseline state. We examined the relationship between factors known to impact LV contractility, whilst delivering BIVENDO pacing at a variety of LV endocardial (LVENDO) locations. We compiled a registry of acute LVENDO pacing studies from five international centres: Johns Hopkins-USA, Bordeaux-France, Eindhoven-The Netherlands, Oxford-United Kingdom, and Guys and St Thomas' NHS Foundation Trust, London-UK. In all, 104 patients incorporating 687 endocardial and 93 epicardial pacing locations were studied. Mean age was 66 ± 11 years, mean left ventricular ejection fraction 24.6 ± 7.7% and mean QRS duration of 163 ± 30 ms. In all, 50% were ischaemic [ischaemic cardiomyopathy (ICM)]. Scarred segments were associated with worse haemodynamics (dp/dtmax; 890 mmHg/s vs. 982 mmHg/s, P < 0.01). Delivering BiVENDO pacing in areas of electrical latency was associated with greater improvements in AHR (P < 0.01). Stimulating late activating tissue (LVLED >50%) achieved greater increases in AHR than non-late activating tissue (LVLED < 50%) (8.6 ± 9.6% vs. 16.1 ± 16.2%, P = 0.002). However, the LVENDO pacing location with the latest Q-LV, was associated with the optimal AHR in just 62% of cases. Identifying viable LVENDO tissue which displays late electrical activation is crucial to identifying the optimal BiVENDO pacing site. Stimulating late activating tissue (LVLED >50%) yields greater improvements in AHR however, the optimal location is frequently not the site of latest activation.

  10. Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: results of the adaptive CRT trial.

    PubMed

    Martin, David O; Lemke, Bernd; Birnie, David; Krum, Henry; Lee, Kathy Lai-Fun; Aonuma, Kazutaka; Gasparini, Maurizio; Starling, Randall C; Milasinovic, Goran; Rogers, Tyson; Sambelashvili, Alex; Gorcsan, John; Houmsse, Mahmoud

    2012-11-01

    In patients with sinus rhythm and normal atrioventricular conduction, pacing only the left ventricle with appropriate atrioventricular delays can result in superior left ventricular and right ventricular function compared with standard biventricular (BiV) pacing. To evaluate a novel adaptive cardiac resynchronization therapy ((aCRT) algorithm for CRT pacing that provides automatic ambulatory selection between synchronized left ventricular or BiV pacing with dynamic optimization of atrioventricular and interventricular delays. Patients (n = 522) indicated for a CRT-defibrillator were randomized to aCRT vs echo-optimized BiV pacing (Echo) in a 2:1 ratio and followed at 1-, 3-, and 6-month postrandomization. The study met all 3 noninferiority primary objectives: (1) the percentage of aCRT patients who improved in their clinical composite score at 6 months was at least as high in the aCRT arm as in the Echo arm (73.6% vs 72.5%, with a noninferiority margin of 12%; P = .0007); (2) aCRT and echo-optimized settings resulted in similar cardiac performance, as demonstrated by a high concordance correlation coefficient between aortic velocity time integrals at aCRT and Echo settings at randomization (concordance correlation coefficient = 0.93; 95% confidence interval 0.91-0.94) and at 6-month postrandomization (concordance correlation coefficient = 0.90; 95% confidence interval 0.87-0.92); and (3) aCRT did not result in inappropriate device settings. There were no significant differences between the arms with respect to heart failure events or ventricular arrhythmia episodes. Secondary end points showed similar benefit, and right-ventricular pacing was reduced by 44% in the aCRT arm. The aCRT algorithm is safe and at least as effective as BiV pacing with comprehensive echocardiographic optimization. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  11. Left atrial booster function in valvular heart disease.

    PubMed

    Heidenreich, F P; Shaver, J A; Thompson, M E; Leonard, J J

    1970-09-01

    This study was designed to assess atrial booster pump action in valvular heart disease and to dissect booster pump from reservoir-conduit functions. In five patients with aortic stenosis and six with mitral stenosis, sequential atrioventricular (A-V) pacing was instituted during the course of diagnostic cardiac catheterization. Continuous recording of valvular gradient allowed estimation of flow for each cardiac cycle by transposition of the Gorlin formula. Left ventricular ejection time and left ventricular stroke work in aortic stenosis or left ventricular mean systolic pressure in mitral stenosis were also determined. Control observations were recorded during sequential A-V pacing with well-timed atrial systole. Cardiac cycles were then produced with no atrial contraction but undisturbed atrial reservoir function by intermittently interrupting the atrial pacing stimulus during sequential A-V pacing. This intervention significantly reduced valvular gradient, flow, left ventricular ejection time, and left ventricular mean systolic pressure or stroke work. Cardiac cycles were then produced with atrial booster action eliminated by instituting synchronous A-V pacing. The resultant simultaneous contraction of the atrium and ventricle not only eliminated effective atrial systole but also placed atrial systole during the normal period of atrial reservoir function. This also significantly reduced all the hemodynamic measurements. However, comparison of the magnitude of change from these two different pacing interventions showed no greater impairment of hemodynamic state when both booster pump action and reservoir function were impaired than when booster pump action alone was impaired. The study confirms the potential benefit of well placed atrial booster pump action in valvular heart disease in man.

  12. The implantable cardioverter defibrillator: technology, indications, and impact on cardiovascular survival.

    PubMed

    Bhatia, Atul; Cooley, Ryan; Berger, Marcie; Blanck, Zalmen; Dhala, Anwer; Sra, Jasbir; Axtell-Mcbride, Kathleen; Vandervort, Cheryl; Akhtar, Masood

    2004-06-01

    Since the introduction of the implantable cardioverter defibrillator (ICD) for the management of patients with high risk of arrhythmic SCD, there has been increasing use of this device. Its basic promise to effectively terminate ventricular tachycardia (VT)-ventricular fibrillation (VF) has been repeatedly met. In several randomized trials, the ICD has been shown to be superior to conventional anti-arrhythmic therapy, both in patients with documented VT-VF (secondary prevention) and those with high risk such as left ventricular ejection fraction and no prior sustained VT-VF (primary prevention). In both groups, the ICD showed overall and cardiac mortality reduction. The device now can more accurately detect VT-VF and differentiate these from other arrhythmias through a series of algorithms and direct-chamber sensing. Therapy options include painless antitachycardia pacing, low-energy cardioversion, and high-energy defibrillation. The technique implant is now simple as a pacemaker with one lead attached to an active (hot) can functioning as the other electrode. Among other improvements is its weight, volume, multiprogrammability, and storage of information,dual-chamber pacing and sensing, dual-chamber defibrillation, and addition of biventricular pacing for cardiac synchronization. It is anticipated that further improvement in ICD technology will take place and the list of indications will grow.

  13. Feasibility of dual-chamber (DDD) pacing via a single-pass (VDD) pacing lead employing a floating atrial ring (dipole): case series, future considerations, and refinements.

    PubMed

    Kassotis, John; Voigt, Louis; Mongwa, Mbu; Reddy, C V R

    2005-01-01

    The objective of this study was to assess the feasibility of DDD pacing from a standard single-pass VDD pacemaker system. Over the past 2 decades significant advances have been made in the development of single-pass VDD pacing systems. These have been shown in long-term prospective studies to effectively preserve atrioventricular (AV)synchrony in patients with AV block and normal sinus node function. What remains problematic is the development of a single-pass pacing system capable of DDD pacing. Such a lead configuration would be useful in those patients with peripheral venous anomalies and in younger patients with congenital anomalies, which may require lead revisions in the future. In addition, with the increased use of resynchronization (biventricular pacing) therapy, the availability of a reliable single-pass lead will minimize operative time, enhance patient safety, and minimize the amount of hardware within the heart. The feasibility of DDD pacing via a Medtronic Capsure VDD-2 (Model #5038) pacing lead was evaluated. Twenty patients who presented with AV block and normal sinus node function were recruited for this study. Atrial pacing thresholds and sensitivities were assessed intraoperatively in the supine position with various respiratory maneuvers. Five patients who agreed to participate in long-term follow-up received a dual-chamber generator and were evaluated periodically over a 12-month period. Mean atrial sensitivity was 2.35 +/- 0.83 mV at the time of implantation. Effective atrial stimulation was possible in all patients at the time of implantation (mean stimulation threshold 3.08 +/- 1.04 V at 0.5 ms [bipolar], 3.34 +/- 0.95 V at 0.5 ms [unipolar]). Five of the 20 patients received a Kappa KDR701 generator, and atrial electrical properties were followed up over a 1-year period. There was no significant change in atrial pacing threshold or incidence of phrenic nerve stimulation over the 1-year follow-up. A standard single-pass VDD pacing lead system was capable of DDD pacing intraoperatively and during long-term follow-up. Despite higher than usual thresholds via the atrial dipole, pacemaker telemetry revealed < 10% use of atrial pacing dipole over a 12-month period, which would minimally deplete the pacemaker's battery. In addition, the telemetry confirmed appropriate sensing and pacing of the atrial dipole throughout the study period. At this time such systems can serve as back-up DDD pacing systems with further refinements required to optimize atrial thresholds in all patients.

  14. Effects of angiotensin-neprilysin inhibition compared to angiotensin inhibition on ventricular arrhythmias in reduced ejection fraction patients under continuous remote monitoring of implantable defibrillator devices.

    PubMed

    de Diego, Carlos; González-Torres, Luis; Núñez, José María; Centurión Inda, Raúl; Martin-Langerwerf, David A; Sangio, Antonio D; Chochowski, Piotr; Casasnovas, Pilar; Blazquéz, Julio C; Almendral, Jesús

    2018-03-01

    Angiotensin-neprilysin inhibition compared to angiotensin inhibition decreased sudden cardiac death in patients with reduced ejection fraction heart failure (rEFHF). The precise mechanism remains unclear. The purpose of this study was to explore the effect of angiotensin-neprilysin inhibition on ventricular arrhythmias compared to angiotensin inhibition in rEFHF patients with an implantable cardioverter-defibrillator (ICD) and remote monitoring. We prospectively included 120 patients with ICD and (1) New York Heart Association functional class ≥II; (2) left ventricular ejection fraction ≤40%; and (3) remote monitoring. For 9 months, patients received 100% angiotensin inhibition with angiotensin-converting enzyme inhibitor (ACEi) or angiotensin receptor blocker (ARB), beta-blockers, and mineraloid antagonist. Subsequently, ACEi or ARB was changed to sacubitril-valsartan in all patients, who were followed for 9 months. Appropriate shocks, nonsustained ventricular tachycardia (NSVT), premature ventricular contraction (PVC) burden, and biventricular pacing percentage were analyzed. Patients were an average age of 69 ± 8 years and had mean left ventricular ejection fraction of 30.4% ± 4% (82% ischemic). Use of beta-blockers (98%), mineraloid antagonist (97%) and antiarrhythmic drugs was similar before and after sacubitril-valsartan. Sacubitril-valsartan significantly decreased NSVT episodes (5.4 ± 0.5 vs 15 ± 1.7 in angiotensin inhibition; P <.002), sustained ventricular tachycardia, and appropriate ICD shocks (0.8% vs 6.7% in angiotensin inhibition; P <.02). PVCs per hour decreased after sacubitril-valsartan (33 ± 12 vs 78 ± 15 in angiotensin inhibition; P <.0003) and was associated with increased biventricular pacing percentage (from 95% ± 6% to 98.8% ± 1.3%; P <.02). Angiotensin-neprilysin inhibition decreased ventricular arrhythmias and appropriate ICD shocks in rEFHF patients under home monitoring compared to angiotensin inhibition. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Self-regulated learning of important information under sequential and simultaneous encoding conditions.

    PubMed

    Middlebrooks, Catherine D; Castel, Alan D

    2018-05-01

    Learners make a number of decisions when attempting to study efficiently: they must choose which information to study, for how long to study it, and whether to restudy it later. The current experiments examine whether documented impairments to self-regulated learning when studying information sequentially, as opposed to simultaneously, extend to the learning of and memory for valuable information. In Experiment 1, participants studied lists of words ranging in value from 1-10 points sequentially or simultaneously at a preset presentation rate; in Experiment 2, study was self-paced and participants could choose to restudy. Although participants prioritized high-value over low-value information, irrespective of presentation, those who studied the items simultaneously demonstrated superior value-based prioritization with respect to recall, study selections, and self-pacing. The results of the present experiments support the theory that devising, maintaining, and executing efficient study agendas is inherently different under sequential formatting than simultaneous. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  16. Adapting the Training Site to Training Needs. Self-Paced Instructional Module. Module Number VII-A.

    ERIC Educational Resources Information Center

    King, Sylvester; Brooks, Kent

    One of 33 self-paced instructional modules for training industry services leaders to provide guidance in the performance of manpower services by public agencies to new and expanding private industry, this module contains three sequential learning activities on adapting the training site to training needs. The first learning activity is designed to…

  17. Factors influencing pacing in triathlon

    PubMed Central

    Wu, Sam SX; Peiffer, Jeremiah J; Brisswalter, Jeanick; Nosaka, Kazunori; Abbiss, Chris R

    2014-01-01

    Triathlon is a multisport event consisting of sequential swim, cycle, and run disciplines performed over a variety of distances. This complex and unique sport requires athletes to appropriately distribute their speed or energy expenditure (ie, pacing) within each discipline as well as over the entire event. As with most physical activity, the regulation of pacing in triathlon may be influenced by a multitude of intrinsic and extrinsic factors. The majority of current research focuses mainly on the Olympic distance, whilst much less literature is available on other triathlon distances such as the sprint, half-Ironman, and Ironman distances. Furthermore, little is understood regarding the specific physiological, environmental, and interdisciplinary effects on pacing. Therefore, this article discusses the pacing strategies observed in triathlon across different distances, and elucidates the possible factors influencing pacing within the three specific disciplines of a triathlon. PMID:25258562

  18. Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

    PubMed

    Konta, Laura; Chubb, Mark Henry; Bostock, Julian; Rogers, Jan; Rosenthal, Eric

    2016-02-01

    Epicardial pacemaker implantation is the favored approach in children weighing <10 kg in many units. The high incidence of premature failure and fractures with earlier epicardial leads led our unit to undertake transvenous pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. Between 1987 and 2003, 37 neonates and infants-median age 6.7 months (1 day to 3 years) and median weight 4.6 kg (2.7-10 kg)-had a permanent transvenous pacing system implanted. Pacing leads were placed into the right ventricular apex/outflow tract through a subclavian vein puncture with a redundant loop in the atrium. Three patients were lost to follow-up, 4 patients died from complications of cardiac surgery, and 2 patients had their system removed. At long-term follow-up in 28 patients at a median of 17.2 (range, 11.2-27.4) years, 10 patients have a single chamber ventricular pacemaker, 14 a dual chamber pacemaker, 3 a biventricular pacemaker, and 1 has a single chamber implantable cardioverter defibrillator. Subclavian vein patency was assessed in 26 patients. The overall subclavian vein occlusion rate was 10 of 13 (77%) <5 kg and 2 of 13 (15%) >5 kg during long-term follow-up. After a median of 14.3 (range, 13.4-17.6) years of pacing, 7 patients continue with their original lead. Transvenous pacing in infants <10 kg results in encouraging short- and long-term clinical outcomes. Subclavian vein occlusion remains an important complication, occurring predominantly in those weighing <5 kg. © 2016 American Heart Association, Inc.

  19. Systematic review and meta-analysis of left ventricular endocardial pacing in advanced heart failure: Clinically efficacious but at what cost?

    PubMed

    Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier

    2018-04-01

    Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.

  20. Incidence and Time Course for Developing Heart Failure With High-Burden Right Ventricular Pacing.

    PubMed

    Merchant, Faisal M; Hoskins, Michael H; Musat, Dan L; Prillinger, Julie B; Roberts, Gregory J; Nabutovsky, Yelena; Mittal, Suneet

    2017-06-01

    Although right ventricular pacing can contribute to cardiomyopathy, the impact of complete atrioventricular block (cAVB) on heart failure (HF) development in pacemaker patients has not been well characterized. We evaluated the incidence and time course for developing HF after pacemaker implantation for cAVB. A MarketScan database identified patients undergoing dual-chamber pacemaker implantation from 2008 to 2014. Patients with cAVB were identified by an atrioventricular node ablation or diagnosis of third-degree AVB. Patients with ≥1 year of continuous MarketScan enrollment before and after implant and without a previous diagnosis of HF were dichotomized into those with cAVB and without AVB. The primary end point was new HF assessed over acute (0-6 months) and chronic (6 months to 4 years) phases post-pacemaker implantation. The cohort included 6994 cAVB patients and 14 208 patients without AVB, followed for 2.35 years (interquartile range, 1.62-3.39 years). After adjustment for baseline covariates, patients with cAVB experienced an increased risk of new-onset HF in the acute phase (hazard ratio, 1.62; 95% confidence interval, 1.48-1.79; P <0.001). Although the risk of HF remained elevated among those with cAVB in the chronic phase, the effect was attenuated (hazard ratio, 1.16; 95% confidence interval, 1.08-1.25; P <0.001). After pacemaker implantation, younger patients (≤55 years of age) and those with an antecedent history of atrial fibrillation experienced the highest risk of HF associated with cAVB. Patients with a diagnosis of cAVB, and thus presumed to have a higher burden of right ventricular pacing, experienced an increased risk of new-onset HF after pacemaker implantation compared with those without AVB. Better tools are needed to identify patients at high risk of developing HF in the setting of right ventricular pacing and to determine whether these patients benefit from upfront biventricular pacing. © 2017 American Heart Association, Inc.

  1. Survival After Rate-Responsive Programming in Patients With Cardiac Resynchronization Therapy-Defibrillator Implants Is Associated With a Novel Parameter: The Heart Rate Score.

    PubMed

    Olshansky, Brian; Richards, Mark; Sharma, Arjun; Wold, Nicholas; Jones, Paul; Perschbacher, David; Wilkoff, Bruce L

    2016-08-01

    Rate-responsive pacing (DDDR) versus nonrate-responsive pacing (DDD) has shown no survival benefit for patients undergoing cardiac resynchronization therapy defibrillator (CRT-D) implants. The heart rate score (HRSc), an indicator of heart rate variation, may predict survival. We hypothesized that high-risk HRSc CRT-D patients will have improved survival with DDDR versus DDD alone. All CRT-D patients in LATITUDE remote monitoring (2006-2011), programmed DDD, had HRSc calculated at first data upload after implant (median 1.4 months). Patients subsequently reprogrammed to DDDR 7.6 median months later were compared with a propensity-matched DDD group and followed for 21.4 median months by remote monitoring. Data were adjusted for age, sex, lower rate limit, percent atrial pacing, percent biventricular pacing, and implant year. The social security death index was used to identify deaths. Remote monitoring provided programming and histogram data. DDDR programming in CRT-D patients was associated with improved survival (adjusted hazard ratio =0.77; P<0.001). However, only those with baseline HRSc ≥70% (2308/6164) had improved HRSc with DDDR (from 88±9% to 78±15%; P<0.001) and improved survival (hazard ratio =0.74; P<0.001). Patients with a high baseline HRSc and significant improvement over time were more likely to survive (hazard ratio =0.63; P=0.006). For patients with HRSc <70%, DDDR reprogramming increased the HRSc from 46±11% to 50±15% (P<0.001); survival did not change. The HRSc did not change with DDD pacing over time. In CRT-D patients with HRSc ≥70%, DDDR reprogramming improved the HRSc and was associated with survival. Patients with lower HRSc had no change in survival with DDDR programming. © 2016 American Heart Association, Inc.

  2. Inappropriate shock and battery switching to "End of Life" in a patient with biventricular ICD during magnetic resonance imaging.

    PubMed

    Atar, İlyas; Bal, Uğur; Ertan, Çağatay; Özin, Bülent; Müderrisoğlu, Haldun

    2016-01-01

    Presence of a cardiac pacemaker or implantable cardioverter defibrillator (ICD) is a relative contraindication to magnetic resonance imaging (MRI). Biventricular ICDs are often used in the treatment of advanced heart failure; however, reports on experience with biventricular ICDs are lacking in the literature. In this case report, we describe a pacemaker-dependent patient with a biventricular ICD on whom an MRI of the lumbar spine was performed without having realized the presence of the ICD.

  3. Parsing the Passive: Comparing Children with Specific Language Impairment to Sequential Bilingual Children

    ERIC Educational Resources Information Center

    Marinis, Theodoros; Saddy, Douglas

    2013-01-01

    Twenty-five monolingual (L1) children with specific language impairment (SLI), 32 sequential bilingual (L2) children, and 29 L1 controls completed the Test of Active & Passive Sentences-Revised (van der Lely 1996) and the Self-Paced Listening Task with Picture Verification for actives and passives (Marinis 2007). These revealed important…

  4. Use of an Active-Fixation Coronary Sinus Lead to Implant a Biventricular Pacemaker via the Femoral Vein

    PubMed Central

    Shandling, Adrian; Donohue, Daniel; Tobias, Serge; Wu, Iris; Brar, Ramandeep

    2010-01-01

    Cardiac resynchronization therapy, which involves the placement of a pacing lead in the right atrium and in each ventricle, is effective in treating heart failure that is caused by left bundle branch block and cardiomyopathy. The left ventricular lead is usually placed into a lateral branch of the coronary sinus via the subclavian route. When the subclavian route is unavailable, insertion of a standard, passive-fixation coronary sinus lead via the femoral approach is feasible; however, the likelihood of subsequent dislodgment is high. Herein, we describe the placement of a novel, self-retaining, active-fixation coronary sinus lead—the Attain StarFix® Model 4195 OTW Lead—in an elderly heart-failure patient, via the femoral approach. We believe that this is the 1st report of this procedure. PMID:20200636

  5. Anodal right ventricular capture during left ventricular stimulation in CRT-implantable cardioverter defibrillators.

    PubMed

    Thibault, Bernard; Roy, Denis; Guerra, Peter G; Macle, Laurent; Dubuc, Marc; Gagné, Pierre; Greiss, Isabelle; Novak, Paul; Furlani, Aldo; Talajic, Mario

    2005-07-01

    Cardiac resynchronization therapy (CRT) has been shown to improve symptoms of patients with moderate to severe heart failure. Optimal CRT involves biventricular or left ventricular (LV) stimulation alone, atrio-ventricular (AV) delay optimization, and possibly interventricular timing adjustment. Recently, anodal capture of the right ventricle (RV) has been described for patients with CRT-pacemakers. It is unknown whether the same phenomenon exists in CRT systems associated with defibrillators (CRT-ICD). The RV leads used in these systems are different from pacemaker leads: they have a larger diameter and shocking coils, which may affect the occurrence of anodal capture. We looked for anodal RV capture during LV stimulation in 11 consecutive patients who received a CRT-ICD system with RV leads with a true bipolar design. Fifteen patients who had RV leads with an integrated design were used as controls. Anodal RV and LV thresholds were determined at pulse width (pw) durations of 0.2, 0.5, and 1.0 ms. RV anodal capture during LV pacing was found in 11/11 patients at some output with true bipolar RV leads versus 0/15 patients with RV leads with an integrated bipolar design. Anodal RV capture threshold was more affected by changes in pw duration than LV capture threshold. In CRT-ICD systems, RV leads with a true bipolar design with the proximal ring also used as the anode for LV pacing are associated with a high incidence of anodal RV capture during LV pacing. This may affect the clinical response to alternative resynchronization methods using single LV stimulation or interventricular delay programming.

  6. HeartWare HVAD for Biventricular Support in Children and Adolescents: The Stanford Experience.

    PubMed

    Stein, Mary Lyn; Yeh, Justin; Reinhartz, Olaf; Rosenthal, David N; Kaufman, Beth D; Almond, Chris S; Hollander, Seth A; Maeda, Katsuhide

    2016-01-01

    Despite increasing use of mechanical circulatory support in children, experience with biventricular device implantation remains limited. We describe our experience using the HeartWare HVAD to provide biventricular support to three patients and compare these patients with five patients supported with HeartWare left ventricular assist device (LVAD). At the end of the study period, all three biventricular assist device (BiVAD) patients had been transplanted and were alive. LVAD patients were out of bed and ambulating a median of 10.5 days postimplantation. The BiVAD patients were out of bed a median of 31 days postimplantation. Pediatric patients with both left ventricular and biventricular heart failure can be successfully bridged to transplantation with the HeartWare HVAD. Rapid improvement in functional status following HVAD implantation for isolated left ventricular support is seen. Patients supported with BiVAD also demonstrate functional recovery, albeit more modestly. In the absence of infection, systemic inflammatory response raises concern for inadequate support.

  7. Mechanisms of decreased left ventricular preload during continuous positive pressure ventilation in ARDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhainaut, J.F.; Devaux, J.Y.; Monsallier, J.F.

    1986-07-01

    Continuous positive pressure ventilation is associated with a reduction in left ventricular preload and cardiac output, but the mechanisms responsible are controversial. The decrease in left ventricular preload may result exclusively from a decreased systemic venous return due to increased pleural pressure, or from an additional effect such as decreased left ventricular compliance. To determine the mechanisms responsible, we studied the changes in cardiac output induced by continuous positive pressure ventilation in eight patients with the adult respiratory distress syndrome. We measured cardiac output by thermodilution, and biventricular ejection fraction by equilibrium gated blood pool scintigraphy. Biventricular end-diastolic volumes weremore » then calculated by dividing stroke volume by ejection fraction. As positive end-expiratory pressure increased from 0 to 20 cm H/sub 2/O, stroke volume and biventricular end-diastolic volumes fell about 25 percent, and biventricular ejection fraction remained unchanged. At 20 cm H/sub 2/O positive end-expiratory pressure, volume expansion for normalizing cardiac output restored biventricular end-diastolic volumes without markedly changing biventricular end-diastolic transmural pressures. The primary cause of the reduction in left ventricular preload with continuous positive pressure ventilation appears to be a fall in venous return and hence in right ventricular stroke volume, without evidence of change in left ventricular diastolic compliance.« less

  8. Minimally invasive surgical implantation of left ventricular epicardial leads for ventricular resynchronization using video-assisted thoracoscopy.

    PubMed

    Fernández, Angel L; García-Bengochea, José B; Ledo, Ramiro; Vega, Marino; Amaro, Antonio; Alvarez, Julián; Rubio, José; Sierra, Juan; Sánchez, Daniel

    2004-04-01

    Cardiac resynchronization via left ventricular or biventricular pacing is an option for selected patients with ventricular systolic dysfunction and widened QRS complex. Stimulation through a coronary vein is the technique of choice for left ventricular pacing, but this approach results in a failure rate of approximately 8%. We describe our initial experience with minimally invasive surgical implantation of left ventricular epicardial leads using video-assisted thoracoscopy. A total of 14 patients with congestive heart failure, NYHA functional class 3.2 (0.6) and mean ejection fraction 22.9 (6.8)% were included in this study. Left bundle branch block, QRS complex >140 ms and abnormal septal motion were observed in all cases. Epicardial leads were implanted on the left ventricular free wall under general anesthesia using video-assisted thoracoscopic surgery. Lead implantation was successful in 13 patients. Conversion to a small thoracotomy was necessary in one patient. All patients were extubated in the operating room. None of the patients died during their hospital stay. Follow-up showed reversal of ventricular asynchrony and significant improvement in ejection fraction and functional class. Minimally invasive surgery for ventricular resynchronization using video-assisted thoracoscopy in selected patients is a safe procedure that makes it possible to choose the best site for lead implantation and provides adequate short- and medium-term stimulation.

  9. Constant DI pacing suppresses cardiac alternans formation in numerical cable models

    NASA Astrophysics Data System (ADS)

    Zlochiver, S.; Johnson, C.; Tolkacheva, E. G.

    2017-09-01

    Cardiac repolarization alternans describe the sequential alternation of the action potential duration (APD) and can develop during rapid pacing. In the ventricles, such alternans may rapidly turn into life risking arrhythmias under conditions of spatial heterogeneity. Thus, suppression of alternans by artificial pacing protocols, or alternans control, has been the subject of numerous theoretical, numerical, and experimental studies. Yet, previous attempts that were inspired by chaos control theories were successful only for a short spatial extent (<2 cm) from the pacing electrode. Previously, we demonstrated in a single cell model that pacing with a constant diastolic interval (DI) can suppress the formation of alternans at high rates of activation. We attributed this effect to the elimination of feedback between the pacing cycle length and the last APD, effectively preventing restitution-dependent alternans from developing. Here, we extend this idea into cable models to study the extent by which constant DI pacing can control alternans during wave propagation conditions. Constant DI pacing was applied to ventricular cable models of up to 5 cm, using human kinetics. Our results show that constant DI pacing significantly shifts the onset of both cardiac alternans and conduction blocks to higher pacing rates in comparison to pacing with constant cycle length. We also demonstrate that constant DI pacing reduces the propensity of spatially discordant alternans, a precursor of wavebreaks. We finally found that the protective effect of constant DI pacing is stronger for increased electrotonic coupling along the fiber in the sense that the onset of alternans is further shifted to higher activation rates. Overall, these results support the potential clinical applicability of such type of pacing in improving protocols of implanted pacemakers, in order to reduce the risk of life-threatening arrhythmias. Future research should be conducted in order to experimentally validate these promising results.

  10. A 2:1 AV rhythm: an adverse effect of a long AV delay during DDI pacing and its prevention by the ventricular intrinsic preference algorithm in DDD mode.

    PubMed

    Minamiguchi, Hitoshi; Oginosawa, Yasushi; Kohno, Ritsuko; Tamura, Masahito; Takeuchi, Masaaki; Otsuji, Yutaka; Abe, Haruhiko

    2012-07-01

    A 91-year-old woman received a dual-chamber pacemaker for sick sinus syndrome and intermittently abnormal atrioventricular (AV) conduction. The pacemaker was set in DDI mode with a 350-ms AV delay to preserve intrinsic ventricular activity. She complained of palpitation during AV sequential pacing. The electrocardiogram showed a 2:1 AV rhythm from 1:1 ventriculoatrial (VA) conduction during ventricular pacing in DDI mode with a long AV interval. After reprogramming of the pacemaker in DDD mode with a 250-ms AV interval and additional 100-ms prolongation of the AV interval by the ventricular intrinsic preference function, VA conduction disappeared and the patient's symptom were alleviated without increasing unnecessary right ventricular pacing. ©2011, The Authors. Journal compilation ©2011 Wiley Periodicals, Inc.

  11. Non-invasive electromechanical activation imaging as a tool to study left ventricular dyssynchronous patients: Implication for CRT therapy.

    PubMed

    Dawoud, Fady; Spragg, David D; Berger, Ronald D; Cheng, Alan; Horáček, B Milan; Halperin, Henry R; Lardo, Albert C

    2016-01-01

    Electromechanical de-coupling is hypothesized to explain non-response of dyssynchrony patient to cardiac resynchronization therapy (CRT). In this pilot study, we investigated regional electromechanical uncoupling in 10 patients referred for CRT using two non-invasive electrical and mechanical imaging techniques (CMR tissue tracking and ECGI). Reconstructed regional electrical and mechanical activation captured delayed LBBB propagation direction from septal to anterior/inferior and finally to lateral walls as well as from LV apical to basal. All 5 responders demonstrated significantly delayed mechanical and electrical activation on the lateral LV wall at baseline compared to the non-responders (P<.05). On follow-up ECGI, baseline electrical activation patterns were preserved in native rhythm and global LV activation time was reduced with biventricular pacing. The combination of novel imaging techniques of ECGI and CMR tissue tracking can be used to assess spatial concordance of LV electrical and mechanical activation to gain insight into electromechanical coupling. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    PubMed

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. The pathophysiology of heart failure: a tale of two old paradigms revisited.

    PubMed

    Ashrafian, Houman; Williams, Lynne; Frenneaux, Michael P

    2008-04-01

    Although our current appreciation of the detrimental role of neurohumoral activation in heart failure (HF) has been intellectually appealing and has led to neurohumoral antagonism that has reduced morbidity and mortality from HF, the persisting disability and death rates remain unacceptably high. In the search for novel strategies to improve on these outcomes, we must reacquaint ourselves with basic cardiac physiology at levels ranging from the molecular to the systemic in order to identify new targets for the treatment of HF. This approach has already begun to yield results; in this review, two such aspects will be focused on: diastolic ventricular interaction and cardiac energetics. These two examples will be used to illuminate how fundamental research has elucidated age-old, although mechanistically elusive, principles (for example, the Frank-Starling law), explained why existing and emerging therapeutic approaches (for example, biventricular pacing in HF) have proved successful, and successfully identified novel therapy modes (for example, perhexiline as an energy augmentation agent).

  14. Total artificial heart implantation for biventricular failure due to eosinophilic myocarditis.

    PubMed

    Kawabori, Masashi; Kurihara, Chitaru; Miller, Yair; Heck, Kent A; Bogaev, Roberta C; Civitello, Andrew B; Cohn, William E; Frazier, O H; Morgan, Jeffrey A

    2017-09-01

    Idiopathic hypereosinophilic syndrome is a condition of unknown etiology characterized by proliferation of eosinophils and their infiltration into tissues. Although cardiac involvement is rare, eosinophilic myocarditis can lead to life-threating fulminant congestive heart failure. Treatment of patients with eosinophilic myocarditis is challenging as heart failure can be caused by biventricular dysfunction. To our knowledge, this is the first case reported in the literature describing a patient with acute severe biventricular heart failure caused by eosinophilic myocarditis with mural left ventricular apical thrombus who was successfully treated with implantation of a total artificial heart as a bridge to heart transplant.

  15. Right Ventricular Failure Post LVAD Implantation Corrected with Biventricular Support: An In Vitro Model.

    PubMed

    Shehab, Sajad; Allida, Sabine M; Davidson, Patricia M; Newton, Phillip J; Robson, Desiree; Jansz, Paul C; Hayward, Christopher S

    Right ventricular failure after left ventricular assist device (LVAD) implantation is associated with high mortality. Management remains limited to pharmacologic therapy and temporary mechanical support. Delayed right ventricular assist device (RVAD) support after LVAD implantation is associated with poorer outcomes. With the advent of miniaturized, durable, continuous flow ventricular assist device systems, chronic RVAD and biventricular assist device (BiVAD) support has been used with some success. The purpose of this study was to assess combined BiVAD and LVAD with delayed RVAD support within a four-elemental mock circulatory loop (MCL) simulating the human cardiovascular system. Our hypothesis was that delayed continuous flow RVAD (RVAD) would produce similar hemodynamic and flow parameters to those of initial BiVAD support. Using the MCL, baseline biventricular heart failure with elevated right and left filling pressures with low cardiac output was simulated. The addition of LVAD within a biventricular configuration improved cardiac output somewhat, but was associated with persistent right heart failure with elevated right-sided filling pressures. The addition of an RVAD significantly improved LVAD outputs and returned filling pressures to normal throughout the circulation. In conclusion, RVAD support successfully restored hemodynamics and flow parameters of biventricular failure supported with isolated LVAD with persistent elevated right atrial pressure.

  16. Cardiac resynchronization therapy by multipoint pacing improves response of left ventricular mechanics and fluid dynamics: a three-dimensional and particle image velocimetry echo study.

    PubMed

    Siciliano, Mariachiara; Migliore, Federico; Badano, Luigi; Bertaglia, Emanuele; Pedrizzetti, Gianni; Cavedon, Stefano; Zorzi, Alessandro; Corrado, Domenico; Iliceto, Sabino; Muraru, Denisa

    2017-11-01

    To characterize the effect of multipoint pacing (MPP) compared to biventricular pacing (BiV) on left ventricle (LV) mechanics and intraventricular fluid dynamics by three-dimensional echocardiography (3DE) and echocardiographic particle imaging velocimetry (Echo-PIV). In 11 consecutive patients [8 men; median age 65 years (57-75)] receiving cardiac resynchronization therapy (CRT) with a quadripolar LV lead (Quartet,St.Jude Medical,Inc.), 3DE and Echo-PIV data were collected for each pacing configuration (CRT-OFF, BiV, and MPP) at follow-up after 6 months. 3DE data included LV volumes, LV ejection fraction (LVEF), strain, and systolic dyssynchrony index (SDI). Echo-PIV was used to evaluate the directional distribution of global blood flow momentum, ranging from zero, when flow force is predominantly along the base-apex direction, up to 90° when it becomes transversal. MPP resulted in significant reduction in end-diastolic and end-systolic volumes compared with both CRT-OFF (P = 0.02; P = 0.008, respectively) and BiV (P = 0.04; P = 0.03, respectively). LVEF and cardiac output were significant superior in MPP compared with CRT-OFF, but similar between MPP and BiV. Statistical significant differences when comparing global longitudinal and circumferential strain and SDI with MPP vs. CRT-OFF were observed (P = 0.008; P = 0.008; P = 0.01, respectively). There was also a trend towards improvement in strain between BiV and MPP that did not reach statistical significance. MPP reflected into a significant reduction of the deviation of global blood flow momentum compared with both CRT-OFF and BiV (P = 0.002) indicating a systematic increase of longitudinal alignment from the base-apex orientation of the haemodynamic forces. These preliminary results suggest that MPP resulted in significant improvement of LV mechanics and fluid dynamics compared with BiV. However, larger studies are needed to confirm this hypothesis. © Crown copyright 2016.

  17. Large animal model of functional tricuspid regurgitation in pacing induced end-stage heart failure.

    PubMed

    Malinowski, Marcin; Proudfoot, Alistair G; Langholz, David; Eberhart, Lenora; Brown, Michael; Schubert, Hans; Wodarek, Jeremy; Timek, Tomasz A

    2017-06-01

    Functional tricuspid regurgitation (FTR) is common in patients with advanced heart failure and frequently complicates left ventricular assist device implantation yet remains poorly understood. We set out to establish large animal model of FTR that could serve as a research platform to investigate the pathogenesis of FTR associated with end-stage heart failure. : Through right thoracotomy, ten adult sheep underwent implantation of pacemaker with epicardial LV lead, five sonomicrometry crystals on the right ventricle, and left and right ventricular telemetry pressure sensors during a beating heart off-pump procedure. After 5 ± 1 days of recovery, baseline haemodynamic, echocardiographic and sonomicrometry data were collected. Animals were paced thereafter at a rate of 220-240 beats/min until the development of heart failure and concomitant tricuspid regurgitation. : Three animals died during early recovery period and one during the pacing phase. Six surviving animals were paced for a mean of 14 ± 5 days. Cardiac function was significantly depressed compared to baseline, with LV ejection fraction falling from 69 ± 2% to 22 ± 4% ( P  < 0.001) and RV fractional area change from 52 ± 11% to 25 ± 9% ( P  = 0.005). All animals developed significant enlargement of tricuspid annulus (from 29.5 ± 1.6 to 36.5 ± 4.5 mm; P  = 0.01) and right ventricle (from 21.9 ± 0.2 to 30.3 ± 0.6 mm; P  = 0.03). Sonomicrometry derived contractility of RV free wall was depressed and at least moderate tricuspid insufficiency developed in all animals. : Biventricular dysfunction, tricuspid annular dilatation and significant FTR were observed in our model of ovine tachycardia induced cardiomyopathy. This animal model reflects the clinical situation of end-stage heart failure patients presenting for mechanical support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Repetitive nonreentrant ventriculoatrial synchrony: An underrecognized cause of pacemaker-related arrhythmia.

    PubMed

    Sharma, Parikshit S; Kaszala, Karoly; Tan, Alex Y; Koneru, Jayanthi N; Shepard, Richard; Ellenbogen, Kenneth A; Huizar, Jose F

    2016-08-01

    Similar to endless loop tachycardia (ELT), repetitive nonreentrant ventriculoatrial synchrony (RNRVAS) is a ventriculoatrial (VA) synchrony pacemaker-mediated arrhythmia. RNRVAS was first described in 1990 and can only occur in the presence of retrograde VA conduction and dual-chamber or cardiac resynchronization devices with tracking (P-synchronous ventricular pacing such as DDD, DDDR) or nontracking pacing modes that allow AV-sequential pacing (DDI, DDIR). RNRVAS is promoted by (1) high lower rate limit or any feature that allows rapid pacing, (2) long AV intervals, or (3) long postventricular atrial refractory period (PVARP). In contrast to ELT, RNRVAS is a less well-recognized form of pacemaker-mediated arrhythmia; thus, unlike ELT, there are no specific device algorithms to prevent, recognize, and terminate RNRVAS. However, RNRVAS has been recently shown to occur frequently. We present a series of cases, some of which were found fortuitously. Owing to its clinical implications, we propose that algorithms should be developed to prevent, identify, and terminate RNRVAS. Published by Elsevier Inc.

  19. Master Skills Check List and Diagnostics.

    ERIC Educational Resources Information Center

    Cherokee Nation of Oklahoma, Tahlequah.

    This publication contains master skills checklists originating from a project to develop instructional materials which are geared to individualized, self-paced learning strategies for Cherokee adults. These checklists break down learning into discrete components that can be sequentially mastered by the student. The master skills checklists are a…

  20. Left bundle branch block, an old-new entity.

    PubMed

    Breithardt, Günter; Breithardt, Ole-Alexander

    2012-04-01

    Left bundle branch block (LBBB) is generally associated with a poorer prognosis in comparison to normal intraventricular conduction, but also in comparison to right bundle branch block which is generally considered to be benign in the absence of an underlying cardiac disorder like congenital heart disease. LBBB may be the first manifestation of a more diffuse myocardial disease. The typical surface ECG feature of LBBB is a prolongation of QRS above 0.11 s in combination with a delay of the intrinsic deflection in leads V5 and V6 of more than 60 ms and no septal q waves in leads I, V5, and V6 due to the abnormal septal activation from right to left. LBBB may induce abnormalities in left ventricular performance due to abnormal asynchronous contraction patterns which can be compensated by biventricular pacing (resynchronization therapy). Asynchronous electrical activation of the ventricles causes regional differences in workload which may lead to asymmetric hypertrophy and left ventricular dilatation, especially due to increased wall mass in late-activated regions, which may aggravate preexisting left ventricular pumping performance or even induce it. Of special interest are patients with LBBB and normal left ventricular dimensions and normal ejection fraction at rest but who may present with an abnormal increase in pulmonary artery pressure during exercise, production of lactate during high-rate pacing, signs of ischemia on myocardial scintigrams (but no coronary artery narrowing), and abnormal ultrastructural findings on myocardial biopsy. For this entity, the term latent cardiomyopathy had been suggested previously.

  1. The total artificial heart for biventricular heart failure and beyond.

    PubMed

    Kasirajan, Vigneshwar; Tang, Daniel G; Katlaps, Gundars J; Shah, Keyur B

    2012-05-01

    Treatment options for late-stage biventricular heart failure are limited but include medical therapy with intravenous inotropes, biventricular assist devices (Bi-VADs) and the total artificial heart (TAH). In this manuscript, we review the indications, surgical techniques and outcomes for the TAH. The TAH offers biventricular replacement, rather than 'assistance', as the device is placed orthotopically after excision of the entire ventricular myocardium and all four native valves. In contrast to patients with Bi-VADs, patients with the TAH have no postoperative inotrope requirements, arrhythmias or inflow/outflow cannulae-related complications. Additionally, patients participate in rehabilitation early after device placement and the development of a portable drive may facilitate hospital discharge in the USA. Furthermore, total heart replacement may be ideal for heart failure associated with unique anatomical and mechanical complications. The TAH is an effective therapeutic option for the treatment of patients dying of heart failure who may not be suitable candidates for left ventricular assist devices.

  2. Creating Shape Templates for Patient Specific Biventricular Modeling in Congenital Heart Disease

    PubMed Central

    Gilbert, Kathleen; Farrar, Genevieve; Cowan, Brett R.; Suinesiaputra, Avan; Occleshaw, Christopher; Pontré, Beau; Perry, James; Hegde, Sanjeet; Marsden, Alison; Omens, Jeff; McCulloch, Andrew; Young, Alistair A.

    2018-01-01

    Survival rates for infants with congenital heart disease (CHD) are improving, resulting in a growing population of adults with CHD. However, the analysis of left and right ventricular function is very time-consuming owing to the variety of congenital morphologies. Efficient customization of patient geometry and function depends on high quality shape templates specifically designed for the application. In this paper, we combine a method for creating finite element shape templates with an interactive template customization to patient MRI examinations. This enables different templates to be chosen depending on patient morphology. To demonstrate this pipeline, a new biventricular template with 162 elements was created and tested in place of an existing 82-element template. The method was able to provide fast interactive biventricular analysis with 0.31 sec per edit response time. The new template was customized to 13 CHD patients with similar biventricular topology, showing improved performance over the previous template and good agreement with clinical indices. PMID:26736353

  3. Vocal cord collapse during phrenic nerve-paced respiration in congenital central hypoventilation syndrome.

    PubMed

    Domanski, Mark C; Preciado, Diego A

    2012-01-01

    Phrenic nerve pacing can be used to treat congenital central hypoventilation syndrome (CCHS). We report how the lack of normal vocal cord tone during phrenic paced respiration can result in passive vocal cord collapse and produce obstructive symptoms. We describe a case of passive vocal cord collapse during phrenic nerve paced respiration in a patient with CCHS. As far as we know, this is the first report of this etiology of airway obstruction. The patient, a 7-year-old with CCHS and normal waking vocal cord movement, continued to require nightly continuous positive airway pressure (CPAP) despite successful utilization of phrenic nerve pacers. On direct laryngoscopy, the patient's larynx was observed while the diaphragmatic pacers were sequentially engaged. No abnormal vocal cord stimulation was witnessed during engaging of either phrenic nerve stimulator. However, the lack of normal inspiratory vocal cord abduction during phrenic nerve-paced respiration resulted in vocal cord collapse and partial obstruction due to passive adduction of the vocal cords through the Bernoulli effect. Bilateral phrenic nerve stimulation resulted in more vocal cord collapse than unilateral stimulation. The lack of vocal cord abduction on inspiration presents a limit to phrenic nerve pacers.

  4. Critically Underdeveloped Left Heart Morphology Associated with Prematurity and Low Birth Weight: Conditional Staged Rehabilitation Towards Biventricular Repair and Time-Related Growth of Left Heart Structures.

    PubMed

    Ahmad, Fareed; Mangano, Robert; Shore, Shirah; Polimenakos, Anastasios

    2017-10-01

    This is a case report of premature low birth weight infant with hypoplasia of left heart structures and a large malaligned VSD who underwent successful staged approach of biventricular repair. We obtained qualitative and quantitative echocardiographic, MRI, and conventional catheterization data to support stepwise strategy towards LV rehabilitation to sustain adequate cardiac output. A thorough and intense follow-up has shown significant growth of left heart structures and favorable clinical status following staged biventricular repair. Our data indicate usefulness of qualitative and quantitative advanced complimentary multi-imaging modalities in predicting the postnatal growth potential of critically underdeveloped left heart structures.

  5. Biventricular assist device for scombroid poisoning with refractory myocardial dysfunction: a bridge to recovery.

    PubMed

    Grinda, Jean-Michel; Bellenfant, Florence; Brivet, François Gilles; Carel, Yvan; Deloche, Alain

    2004-09-01

    We report the usefulness of biventricular mechanical circulatory support in a 36-yr-old woman with refractory myocardial dysfunction resulting from scombroid poisoning. Case report. Medical and surgical university care units. A previously healthy 36-yr-old woman with severe myocardial dysfunction unresponsive to epinephrine (1.3 microg/kg/min) and dobutamine (18 microg/kg/min) after the ingestion of cooked fresh tuna. Implantation at day 3 of a biventricular assist device consisting of two paracorporeal pneumatic pumps set at 70 beats/min to reach an output of 5.6 L/min during 8 days. The biventricular mechanical circulatory assist device allowed weaning of the inotropic drugs, maintenance of end-organ function, and support of the patient until myocardial recovery. The patient was successfully explanted 11 days after ingestion. Cardiac function had totally recovered, but a stroke was noted. At 3-yrs follow-up, there was no cardiac or neurologic sequela. This report describes severe myocardial dysfunction secondary to scombroid poisoning and demonstrates the usefulness of a mechanical circulatory assist device as a bridge to recovery.

  6. Total artificial heart in the pediatric patient with biventricular heart failure.

    PubMed

    Park, S S; Sanders, D B; Smith, B P; Ryan, J; Plasencia, J; Osborn, M B; Wellnitz, C M; Southard, R N; Pierce, C N; Arabia, F A; Lane, J; Frakes, D; Velez, D A; Pophal, S G; Nigro, J J

    2014-01-01

    Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m(2), thus, limiting pediatric application of this device. This unique case report shares this pediatric institution's first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m(2)) below the recommendation of 1.7 m(2). A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would fit, as well as postoperative complications in this smaller pediatric patient.

  7. Global Bi-ventricular endocardial distribution of activation rate during long duration ventricular fibrillation in normal and heart failure canines.

    PubMed

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Han, Yanxin; Wang, Yilong; Huang, Shangwei; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2017-04-13

    The objective of this study was to detect differences in the distribution of the left and right ventricle (LV & RV) activation rate (AR) during short-duration ventricular fibrillation (SDVF, <1 min) and long-duration ventricular fibrillation VF (LDVF, >1 min) in normal and heart failure (HF) canine hearts. Ventricular fibrillation (VF) was electrically induced in six healthy dogs (control group) and six dogs with right ventricular pacing-induced congestive HF (HF group). Two 64-electrode basket catheters deployed in the LV and RV were used for global endocardium electrical mapping. The AR of VF was estimated by fast Fourier transform analysis from each electrode. In the control group, the LV was activated faster than the RV in the first 20 s, after which there was no detectable difference in the AR between them. When analyzing the distribution of the AR within the bi-ventricles at 3 min of LDVF, the posterior LV was activated fastest, while the anterior was slowest. In the HF group, a detectable AR gradient existed between the two ventricles within 3 min of VF, with the LV activating more quickly than the RV. When analyzing the distribution of the AR within the bi-ventricles at 3 min of LDVF, the septum of the LV was activated fastest, while the anterior was activated slowest. A global bi-ventricular endocardial AR gradient existed within the first 20 s of VF but disappeared in the LDVF in healthy hearts. However, the AR gradient was always observed in both SDVF and LDVF in HF hearts. The findings of this study suggest that LDVF in HF hearts can be maintained differently from normal hearts, which accordingly should lead to the development of different management strategies for LDVF resuscitation.

  8. Auditory Imagery Shapes Movement Timing and Kinematics: Evidence from a Musical Task

    ERIC Educational Resources Information Center

    Keller, Peter E.; Dalla Bella, Simone; Koch, Iring

    2010-01-01

    The role of anticipatory auditory imagery in music-like sequential action was investigated by examining timing accuracy and kinematics using a motion capture system. Musicians responded to metronomic pacing signals by producing three unpaced taps on three vertically aligned keys at the given tempo. Taps triggered tones in two out of three blocked…

  9. The Cardiovascular Effects of Obesity on Ventricular Function and Mass in Patients after Tetralogy of Fallot Repair.

    PubMed

    Fogel, Mark A; Pawlowski, Thomas; Keller, Marc S; Cohen, Meryl S; Goldmuntz, Elizabeth; Diaz, Laura; Li, Christine; Whitehead, Kevin K; Harris, Matthew A

    2015-08-01

    To determine the cardiovascular effects of obesity on patients with tetralogy of Fallot (TOF) repair. Ventricular performance measures were compared between obese (body mass index [BMI] ≥95%), overweight (85% ≤BMI <95%), and normal weight subjects (BMI <85%) in a retrospective review of patients with TOF who underwent cardiac magnetic resonance from 2005-2010. Significance was P < .05. Of 260 consecutive patients with TOF, 32 were obese (12.3%), 48 were overweight (18.5%), and 180 were normal weight (69.2%). Biventricular mass was increased in obese compared with normal weight patients with right ventricular mass more affected than left ventricular mass. Obese patients demonstrated decreased biventricular end-diastolic volume (EDV) and stroke volume (SV) when indexed to body surface area (BSA) with an increased heart rate when compared with normal weight patients; cardiac index, ejection fraction, and pulmonary regurgitation fraction were similar. When indexed to ideal BSA, biventricular EDV and SV were similar. EDV and SV for overweight patients were nearly identical to normal weight patients with ventricular mass in between the other 2 groups. Approximately 12% of patients after TOF repair referred for cardiac magnetic resonance in a tertiary referral center are obese with increased biventricular mass. Obese patients and normal weight patients have similar cardiac indices, however, when indexed to actual BSA, obese patients demonstrate decreased EDV and SV with increased heart rate and similar cardiac indices. When indexed to ideal BSA, no differences in biventricular volumes were noted. Copyright © 2015. Published by Elsevier Inc.

  10. Biventricular Takotsubo cardiomyopathy in Graves hyperthyroidism.

    PubMed

    Perkins, Matthew J; Schachter, David T

    2014-03-01

    Graves hyperthyroidism is commonly seen in clinical practice and Takotsubo stress cardiomyopathy is an increasingly recognized cardiac complication of physical or emotional stress. We report the rare case of a patient with Graves hyperthyroidism that was complicated by severe biventricular takotsubo cardiomyopathy, which was demonstrated on heart catheterization. After appropriate pharmacologic treatment of her hyperthyroidism, she had complete resolution of her cardiomyopathy.

  11. Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study.

    PubMed

    Kantharia, Bharat K; Freedman, Roger A; Hoekenga, David; Tomassoni, Gery; Worley, Seth; Sorrentino, Robert; Steinhaus, David; Wolkowicz, Joel M; Syed, Zaffer A

    2007-11-01

    Different pacing sites and various algorithms have been utilized to prevent atrial fibrillation (AF) in pacemaker recipients. However, the optimal pacing rate settings have not yet been established. In this randomized, prospective, multicentre, single-blinded, cross over study, rate-adaptive pacing at a high base rate (BR) in patients, age 60 years or above, or a history of paroxysmal AF, who underwent dual-chamber (DDD) pacemaker implantation for standard pacing indications, was evaluated for prevention of AF. In the study cohort of 145 patients implanted with DDD pacemakers with a programmable rest rate (RR) feature, the BR/RR settings were sequentially but randomly adjusted as follows: 60 bpm/Off for the baseline quarter (initial 3 months) and then to either 'A-B-C' or 'C-B-A' settings (A = 70/65 bpm, B = 70/Off, C = 80/65 bpm) for the subsequent quarters each of 3 months duration. Data on automatic mode switch episodes, device diagnostics, and a questionnaire evaluating pacemaker awareness and palpitations were collected. Ninety-nine patients, mean age 77 +/- 10 years, who completed the study protocol and followed for 12 months did not show significant differences in the number of mode switch episodes between any settings used. The percentage of atrial pacing was lower during baseline pacing compared to settings A, B, and C (P < 0.0001). Setting C produced a higher percentage of atrial pacing than A and B (P < 0.01). Although a higher percentage of atrial pacing correlated with a lower incidence of mode switch episodes, there was no statistically significant difference in the number of mode switch episodes between settings A, B, and C. There were no significant differences in the questionnaire scores relating to pacemaker awareness or palpitation. Overdrive single-site pacing in the right atrium achieved by programming analysed settings in the present study did not reduce AF as assessed by mode switch episodes. Additionally, no change in the symptoms of arrhythmia or awareness of pacing was seen.

  12. Hematocrit Levels, Blood Testing, and Blood Transfusion in Infants After Heart Surgery.

    PubMed

    Delgado-Corcoran, Claudia; Wolpert, Katherine H; Lucas, Kathryn; Bodily, Stephanie; Presson, Angela P; Bratton, Susan L

    2016-11-01

    To determine whether judicious blood testing impacts timing or amount of packed RBC transfusions in infants after heart surgery. A retrospective study comparing before and after initiation of a quality improvement process. A university-affiliated cardiac ICU at a tertiary care children's hospital. Infants less than 1 year old with Risk Adjustment for Congenital Heart Surgery category 4, 5, 6, or d-transposition of great arteries (Risk Adjustment for Congenital Heart Surgery 3) consecutively treated during 2010 through 2013. A quality improvement process implemented in 2011 to decrease routine laboratory testing after surgery. Fifty-two infants preintervention and 214 postintervention had similar age, weight, proportion of cyanotic lesions, and surgical complexity. Infants with single versus biventricular physiology were compared separately. The number of laboratory tests per patient adjusted for cardiac ICU length of stay (laboratory tests/patient/day) was significantly lower in postintervention populations for single and biventricular groups (9 vs 15 and 10 vs 15, respectively; p < 0.001). The proportion of single ventricle patients transfused post- and preintervention was not statistically different (72% vs 90%; p = 0.130). Transfusion in the biventricular groups was the same over time (65% vs 65%). Time to first transfusion was significantly longer in the postintervention single ventricle group (4 vs 1 d; p < 0.001), and was not statistically different in the biventricular patients (4 vs 7 d; p = 0.058). The median hematocrit level at first transfusion was significantly lower (37% vs 40%; p = 0.004) postintervention in the cyanotic population, but did not differ in the biventricular group (31% vs 31%; p = 0.840). In infants after heart surgery, blood testing targeted to individual needs significantly decreased the number of blood tests, but did not significantly decrease postoperative blood transfusion.

  13. Unbalanced atrioventricular septal defect: definition and decision making.

    PubMed

    Overman, David M; Baffa, Jeanne M; Cohen, Meryl S; Mertens, Luc; Gremmels, David B; Jegatheeswaram, Anusha; McCrindle, Brian W; Blackstone, Eugene H; Morell, Victor O; Caldarone, Christopher; Williams, William G; Pizarro, Christian

    2010-04-01

    Unbalanced atrioventricular septal defect is an uncommon lesion with widely varying anatomic manifestations. When unbalance is severe, diagnosis and treatment is straightforward, directed toward single-ventricle palliation. Milder forms, however, pose a challenge to current diagnostic and therapeutic approaches. The transition from anatomies that are capable of sustaining biventricular physiology to those that cannot is obscure, resulting in uneven application of surgical strategy and excess mortality. Imprecise assessments of ventricular competence have dominated clinical decision making in this regard. Malalignment of the atrioventricular junction and its attendant derangement of inflow physiology is a critical factor in determining the feasibility of biventricular repair in the setting of unbalanced atrioventricular septal defect. The atrioventricular valve index accurately identifies unbalanced atrioventricular septal defect and also brings into focus a zone of transition from anatomies that can support a biventricular end state and those that cannot.

  14. A systematic approach to designing reliable VV optimization methodology: assessment of internal validity of echocardiographic, electrocardiographic and haemodynamic optimization of cardiac resynchronization therapy.

    PubMed

    Kyriacou, Andreas; Li Kam Wa, Matthew E; Pabari, Punam A; Unsworth, Beth; Baruah, Resham; Willson, Keith; Peters, Nicholas S; Kanagaratnam, Prapa; Hughes, Alun D; Mayet, Jamil; Whinnett, Zachary I; Francis, Darrel P

    2013-08-10

    In atrial fibrillation (AF), VV optimization of biventricular pacemakers can be examined in isolation. We used this approach to evaluate internal validity of three VV optimization methods by three criteria. Twenty patients (16 men, age 75 ± 7) in AF were optimized, at two paced heart rates, by LVOT VTI (flow), non-invasive arterial pressure, and ECG (minimizing QRS duration). Each optimization method was evaluated for: singularity (unique peak of function), reproducibility of optimum, and biological plausibility of the distribution of optima. The reproducibility (standard deviation of the difference, SDD) of the optimal VV delay was 10 ms for pressure, versus 8 ms (p=ns) for QRS and 34 ms (p<0.01) for flow. Singularity of optimum was 85% for pressure, 63% for ECG and 45% for flow (Chi(2)=10.9, p<0.005). The distribution of pressure optima was biologically plausible, with 80% LV pre-excited (p=0.007). The distributions of ECG (55% LV pre-excitation) and flow (45% LV pre-excitation) optima were no different to random (p=ns). The pressure-derived optimal VV delay is unaffected by the paced rate: SDD between slow and fast heart rate is 9 ms, no different from the reproducibility SDD at both heart rates. Using non-invasive arterial pressure, VV delay optimization by parabolic fitting is achievable with good precision, satisfying all 3 criteria of internal validity. VV optimum is unaffected by heart rate. Neither QRS minimization nor LVOT VTI satisfy all validity criteria, and therefore seem weaker candidate modalities for VV optimization. AF, unlinking interventricular from atrioventricular delay, uniquely exposes resynchronization concepts to experimental scrutiny. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    PubMed

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P < 0.001). The accuracy of the axis shift method was 66.4%, which was significantly lower than the modified Ammann algorithm (P < 0.001) and similar to the original one (P = 0.412). However, in the ECGs with QRS axis shift, 96.8% were correctly classified. LV preactivation or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall could elevate the accuracies of the modified Ammann algorithm and the QRS axis shift method. The accuracy of the modified Ammann algorithm is greatly improved. The QRS axis shift method can help diagnose LV capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  16. Seventeen-month-long paracorporeal biventricular mechanical support as a bridge to transplantation for severe dilated cardiomyopathy.

    PubMed

    Kitamura, Tadashi; Torii, Shinzo; Oka, Norihiko; Horai, Tetsuya; Itatani, Keiichi; Yoshii, Takeshi; Nakamura, Yuki; Shibata, Miyuki; Tamura, Tomoki; Araki, Haruna; Matsunaga, Yoshikiyo; Miyaji, Kagami

    2015-03-01

    The long-term management of paracorporeal biventricular assist devices (BiVAD) is difficult because of significant risks of bleeding, thrombosis, and infection. Here we report the case of a 41-year-old woman with severe dilated cardiomyopathy who developed serious cerebral bleeding after receiving a paracorporeal BiVAD but recovered well after treatment. She eventually underwent cardiac transplantation 17 months after implantation of the paracorporeal BiVAD.

  17. Sympathoinhibition and hypotension in carotid sinus hypersensitivity

    NASA Technical Reports Server (NTRS)

    Smith, M. L.; Ellenbogen, K. A.; Eckberg, D. L.

    1992-01-01

    Carotid sinus reflex hypersensitivity is a known cause of syncope in humans. The condition is characterized by cardioinhibition and vasodepression, each to varying degrees. The extent and importance of sympathoinhibition has not been determined in patients with carotid sinus hypersensitivity. This study reports on the extent of sympathoinhibition measured directly directly during carotid massage with and without atrioventricular sequential pacing, in a patient with symptomatic carotid sinus reflex hypersensitivity. Carotid massage elicited asystole, hypotension and complete inhibition of muscle sympathetic nerve activity. Carotid massage during atrioventricular pacing produced similar sympathoinhibition, but with minimal hypotension. Therefore, sympathoinhibition did not contribute importantly to the hypotension during carotid massage in the supine position in this patient. Further investigations are required to elucidate the relation of sympathoinhibition to hypotension in patients with carotid sinus hypersensitivity in the upright position.

  18. Neurodevelopmental Outcome in Children after Fetal Cardiac Intervention for Aortic Stenosis with Evolving Hypoplastic Left Heart Syndrome.

    PubMed

    Laraja, Kristin; Sadhwani, Anjali; Tworetzky, Wayne; Marshall, Audrey C; Gauvreau, Kimberlee; Freud, Lindsay; Hass, Cara; Dunbar-Masterson, Carolyn; Ware, Janice; Lafranchi, Terra; Wilkins-Haug, Louise; Newburger, Jane W

    2017-05-01

    To characterize neurodevelopmental outcomes after fetal aortic valvuloplasty for evolving hypoplastic left heart syndrome and determine the risk factors for adverse neurodevelopment. Questionnaires were mailed to families of children who underwent fetal aortic valvuloplasty from 2000 to 2012, and medical records were reviewed retrospectively. The primary outcome was the General Adaptive Composite score of the Adaptive Behavior Assessment System Questionnaire-Second Edition. Other questionnaires included the Behavior Assessment System for Children, Behavior Rating Inventory of Executive Function, Ages and Stages, and Pediatric Quality of Life Inventory. Among 69 eligible subjects, 52 (75%) completed questionnaires at median age of 5.5 (range 1.3-12) years; 30 (58%) had biventricular status circulation. The General Adaptive Composite mean score (92 ± 17) was lower than population norms (P < .001) and similar to published reports in patients with hypoplastic left heart syndrome without fetal intervention; scores in the single ventricular versus biventricular group were 97 ± 19 vs 89 ± 14, respectively (P = .10). On multivariable analysis, independent predictors of a lower General Adaptive Composite score were total hospital duration of stay in the first year of life (P = .001) and, when forced into the model, biventricular status (P = .02). For all other neurodevelopmental questionnaires (Behavior Assessment System for Children, Behavior Rating Inventory of Executive Function, Ages and Stages, Pediatric Quality of Life Inventory), most subscale scores for patients with biventricular and single ventricular status were similar. Children who underwent fetal aortic valvuloplasty have neurodevelopmental delay, similar to patients with hypoplastic left heart syndrome without fetal intervention. Achievement of biventricular circulation was not associated with better outcomes. We infer that innate patient factors and morbidity during infancy have the greatest effect on neurodevelopmental outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Investigation of mechanisms and non-pharmacological therapy of cardiac arrhythmias

    NASA Astrophysics Data System (ADS)

    Vago, Hajnalka

    Learning of mechanisms of arrhythmias may contribute substantially to the development of effective pharmacological and non-pharmacological therapeutic methods. Clinical relevance of endothelin-1 (ET-1), a strong vasoconstrictor and arrhythmogenic endogenous substrate, is not clarified yet. In our experimental studies, performed in the in situ canine heart, electrophysiological effects and the role in the pathomechanism of malignant ventricular tachyarrhythmias of endogenous and exogenous ET-1 was investigated. It has been proven in the in vivo ischaemia-reperfusion canine heart model, that during reperfusion ET-1 and big-ET levels increase in the coronary sinus, however there was no correlation between endothelin levels and electrophysiological changes. ET A-receptor antagonist darusentan does not prevent electrophysiological changes and development of ventricular tachyarrhythmias during ischaemia and reperfusion. On the contrary, during ischaemia endogenous ET-1 tends to show balancing effect. It has been proven that administration of high dose intracoronary ET-1 bolus has dual, ischaemic and direct, electrophysiological effect. It has been shown for the first time, that ET-1 causes monophasic action potential (MAP) and T-wave alternant. Our clinical study leads to the conclusion that previous atrial fibrillation, absence of preoperative beta-blocker treatment and combined heart surgery are strong predictors of atrial fibrillation following open heart surgery. The basis of new nonpharmacological therapies is the learning of pathomechanisms of arrhythmias and in some cases heart failure, which is an arrhythmogenic substrate. In our experimental study reliable MAP measurements, suitable for investigation of arrhythmogenesis, were performed for the first time using fractally coated ablation catheters during spontaneous rate and during stimulations. It has been proven that radiofrequency ablation affects significantly MAP parameters. In Hungary, we were the first to apply effectively biatrial pacemaker and biatrial cardioverter defibrillator for the prevention of paroxysmal atrial fibrillation. In the majority of patients frequency of paroxysmal atrial fibrillation decreased significantly due to biatrial stimulation or combined pharmacological and resynchronisation therapy. Parasymphathetic cardiac neurostimulation is a promising new non-pharmacological treatment option in certain types of arrhythmias. In our clinical study we were able to stimulate cardiac parasympathetic nerves innervating atrioventricular node achieving ventricular rate control during atrial tachyarrhythmias with chronically implanted coronary sinus lead. In our study biventricular pacemakers and cardioverter defibrillators were applied successfully in the treatment of drug refractory congestive heart failure combined with inter- and/or intraventricular conduction disturbances. AV sequential left sided chronic pacing using a single lead located in the coronary sinus has not been previously reported. Left sided DDD pacing was effective chronically in the improvement of the functional stage of patient suffering from congestive heart disease combined with left bundle branch block and binodal disease. Parallel with the investigation of pathomechanism of life-threatening ventricular tachyarrhythmias and the most common, clinically relevant atrial fibrillation due to recent technical development, we were able to support nonpharmacological therapeutic modalities, gaining popularity in clinical management, with novel observations.

  20. Accelerated heart function recovery after therapeutic plasma exchange in patient treated with biventricular mechanical circulatory support for severe peripartum cardiomyopathy.

    PubMed

    Łasińska-Kowaraa, Magdalena; Lango, Romuald; Kowalik, Maciej; Jarmoszewicz, Krzysztof

    2014-12-01

    We describe a case of severe peripartum cardiomyopathy treated with biventricular mechanical circulatory support, where rapid haemodynamic recovery was observed after therapeutic plasma exchange, used as an adjunct to the inhibition of prolactin release. The patient recovered and after 2 months was discharged from the hospital without clinical symptoms of heart disease. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Engaging in paced mating, but neither exploratory, anti-anxiety, nor social behavior, increases 5α-reduced progestin concentrations in midbrain, hippocampus, striatum, and cortex

    PubMed Central

    Frye, Cheryl A; Paris, Jason J; Rhodes, Madeline E

    2010-01-01

    Sequential actions of 17β-estradiol (E2) and progesterone (P4) in the hypothalamus and the P4 metabolite, 5α-pregnan-3α-ol-20-one (3α,5α-THP), in the midbrain ventral tegmental area (VTA) respectively mediate the initiation and intensity of lordosis of female rats and mayalso modulate anxiety and social behaviors, through actions in these, and/or other brain regions. Biosynthesis of E2, P4, and 3α,5α-THP can also occur in brain, independent of peripheral gland secretion, in response to environmental/behavioral stimuli. The extent to which engaging in tasks related to reproductive behaviors and/or mating increased E2 or progestin concentrations in brain was investigated. In Experiment 1, proestrous rats were randomly assigned to be tested in individual tasks, including the open field, elevated plus maze, partner preference, social interaction, or no test control, in conjunction with paced mating or no mating. Engaging in paced mating, but not other behaviors, significantly increased dihydroprogesterone (DHP) and 3α,5α-THP levels in midbrain, hippocampus, striatum, and cortex. In Experiment 2, proestrous rats were tested in the combinations of the above tasks (open field and elevated plus maze, partner preference, and social interaction) with or without paced mating. As in Experiment 1, only engaging in paced mating increased DHP and 3α,5α-THP concentrations in midbrain, hippocampus, striatum, and cortex. Thus, paced mating enhances concentrations of 5α-reduced progestins in brain areas associated with reproduction (midbrain), as well as exploration/anxiety (hippocampus and striatum) and social behavior (cortex). PMID:17379660

  2. Interdependence of right ventricular systolic function and left ventricular filling and its association with outcome for patients with pulmonary hypertension.

    PubMed

    Motoji, Yoshiki; Tanaka, Hidekazu; Fukuda, Yuko; Sano, Hiroyuki; Ryo, Keiko; Imanishi, Junichi; Miyoshi, Tatsuya; Sawa, Takuma; Mochizuki, Yasuhide; Matsumoto, Kensuke; Emoto, Noriaki; Hirata, Ken-ichi

    2015-04-01

    Although impaired right ventricular (RV) performance has been associated with adverse outcomes for pulmonary hypertension (PH) patients, the relationship between bi-ventricular interdependence and outcomes is not yet fully understood. We studied 96 PH patients. RV systolic function was assessed by means of RV free-wall longitudinal speckle-tracking strain (RV-free), and left ventricular (LV) filling as early diastolic transmitral flow velocity (TMF-E). RV-free ≤19 % and TMF-E <60 cm/s were adopted as pre-defined cut-offs for RV systolic dysfunction and LV under-filling, respectively, associated with worse outcomes. Long-term outcome was tracked over 2.2 years. RV-free correlated significantly with TMF-E (r = 0.57, p < 0.001).TMF-E and RV-free were significantly lower in patients with than in those without cardiac events. RV systolic dysfunction and LV under-filling was observed in 35 patients. These features were associated with worse long-term survival compared to other sub-groups (log-rank p = 0.012). A sequential Cox model based on clinical variables including world health organization functional class IV and brain natriuretic peptide >150 pg/dl (χ(2) = 1.2) was improved by the addition of RV-free (χ(2) = 5.5, p = 0.04) as well as of TMF-E (χ(2) = 11.5, p = 0.01). In conclusions, RV systolic function was shown to correlate significantly with LV filling in PH patients. In addition, not only assessment of RV systolic function, but also of a combined bi-ventricular parameter comprising RV systolic function and LV filling may well have clinical implications for more successful management of PH patients.

  3. Right Ventricle Dysfunction and Pre Implantation Vasopressors in Refractory ARDS Supported by VV-ECMO.

    PubMed

    Lazzeri, Chiara; Bonizzoli, Manuela; Cianchi, Giovanni; Batacchi, Stefano; Guetti, Cristiana; Cozzolino, Morena; Bernardo, Pasquale; Peris, Adriano

    2017-10-31

    Acute respiratory distress syndrome (ARDS) has been shown to be frequently associated with haemodynamic instability requiring the use of vasopressors. To date, there is still some uncertainty in the use of veno-venous Extracorporeal Membrane Oxygenation (VV-ECMO) in haemodynamically unstable ARDS patients. We therefore assessed whether patients receiving pre ECMO vasopressors had a worse prognosis and, furthermore, we reviewed the factors associated with the use of pre ECMO vasopressors in 92 consecutive patients with refractory ARDS treated with VV-ECMO. All patients were submitted to an echocardiogram before implantation. In our series, 55 patients (59.7%) were given a vasopressor. Septic shock is the main cause of vasopressor requirement (45.5%). When compared with patients without vasopressors, the subgroup under vasopressors showed a significantly higher sequential organ failure assessment (SOFA) score (p=0.040), a lower pH (p=0.013), lower pO2 values (p=0.030) and higher lactate levels (p=0.024). A higher incidence of right ventricular (RV) dysfunction and of biventricular dysfunction were observed in patients under vasopressors (p=0.018 and p=0.036, respectively). The intensive care unit (ICU) mortality rate was 43.4% (40/92) with no difference between the two subgroups. In refractory ARDS requiring VV-ECMO infusion of vasopressors is needed in a high proportion of patients, who did not exhibit a worse prognosis when compared to haemodynamically stable patients. Pre ECMO echocardiography helps in characterising these patients since they showed a higher incidence of RV (and biventricular) dysfunction. According to our data, in ARDS patients refractory to conventional treatment, haemodynamic instability should not be considered a contraindication to VV-ECMO support. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  4. Important knowledge for parents of children with heart disease: parent, nurse, and physician views.

    PubMed

    Daily, Joshua; FitzGerald, Mike; Downing, Kimberly; King, Eileen; del Rey, Javier Gonzalez; Ittenbach, Richard; Marino, Bradley

    2016-01-01

    Parental understanding of their children's heart disease is inadequate, which may contribute to poor health outcomes. The purpose of this study was to determine what parental knowledge is important in the care of children with heart disease from the perspective of parents, nurses, and physicians. Focus groups were formed with parents of children with single ventricle congenital heart disease (CHD), biventricular CHD, and heart transplantation, and with nurses and physicians who provide care for these children. A nominal group technique was used to identify and prioritise important parental knowledge items and themes. The voting data for each theme were reported by participant type--parent, nurse, and physician--and patient diagnosis--single ventricle CHD, biventricular CHD, and heart transplantation. The following three themes were identified as important by all groups: recognition of and response to clinical deterioration, medications, and prognosis and plan. Additional themes that were unique to specific groups included the following: medical team members and interactions (parents), tests and labs (parents), neurodevelopmental outcomes and interventions (physicians), lifelong disease requiring lifelong follow-up (physicians and nurses), and diagnosis, physiology, and interventions (single ventricle and biventricular CHD). Parents, nurses, and physicians have both common and unique views regarding what parents should know to effectively care for their children with single ventricle CHD, biventricular CHD, or heart transplantation. Specific targeted parental education that incorporates these findings should be provided to each group. Further development of questionnaires regarding parental knowledge with appropriate content validity is warranted.

  5. Factors affecting death and progression towards next stage following modified Blalock-Taussig shunt in neonates.

    PubMed

    Alsoufi, Bahaaldin; Gillespie, Scott; Mori, Makoto; Clabby, Martha; Kanter, Kirk; Kogon, Brian

    2016-07-01

    The modified Blalock-Taussig shunt (BTS) is utilized to palliate neonates born with restrictive pulmonary blood flow including those with single ventricle (SV) or biventricular (BV) cardiac anomalies. We aim in the current study to report palliation outcomes of neonates with BTS and to examine factors affecting death and progression to the subsequent stage of palliation or repair. Between 2002 and 2012, 341 patients underwent BTS including 175 with SV and 166 with BV anomalies. Competing risk analysis modelled events after BTS (death or transplantation, transition to Glenn shunt or biventricular repair) and examined risk factors affecting outcomes. SV patients had a higher incidence of extracorporeal membrane oxygenation (ECMO) support requirement (12 vs 4%, P = 0.004) and unplanned cardiac reoperation (14 vs 7%, P = 0.051) than their BV counterparts. Additionally, hospital mortality was higher in SV than in BV patients (15 vs 3%, P < 0.001). In SV patients, competing risk analysis showed that, 2 years following BTS, 27% of patients had died or received transplantation and 73% had undergone the Glenn shunt. On multivariable analysis, factors associated with time until death or transplantation prior to Glenn were cardiopulmonary bypass [hazard ratio (HR) 3.6 (2.0-6.4), P < 0.001], unplanned cardiac reoperation [HR 2.4 (1.3-4.6), P = 0.007], pulmonary atresia [HR 2.0 (1.1-3.7), P = 0.026] and the shunt size/weight ratio [HR 1.3 (1.1-1.4) per 0.1 increase, P = 0.001]. In BV patients, competing risk analysis showed that, 2 years following BTS, 13% of patients had died or received transplantation, 85% had undergone biventricular repair and 2% were alive without biventricular repair. On multivariable analysis, factors associated with time until death or transplantation prior to biventricular repair were genetic syndromes and extracardiac malformations [HR 6.1 (2.0-18.2), P = 0.001], weight ≤2.5 kg [HR 5.6 (2.0-16.0), P = 0.001] and male gender [HR 3.4 (1.1-11.0), P = 0.041]. Palliation with BTS continues to be associated with significant operative morbidity and mortality. In addition to hospital death, there is an important interstage attrition risk prior to subsequent palliation or biventricular repair. Inherent patient characteristics (i.e. genetic syndromes and low weight) and anatomical details (i.e. SV, pulmonary atresia and concomitant cardiac anomalies) are associated with worse survival. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Passive control of a biventricular assist device with compliant inflow cannulae.

    PubMed

    Gregory, Shaun David; Pearcy, Mark John; Timms, Daniel

    2012-08-01

    Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow balancing Starling response is diminished in both ventricles. The reliability of sensor and sensorless-based control systems which aim to control VAD flow based on preload has limitations, and, thus, an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a CIC could potentially be used as a passive control system to prevent suction events in rotary left, right, and biventricular support. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Detecting Subclinical Biventricular Impairment in Scleroderma Patients by Use of Pulsed-Wave Tissue Doppler Imaging

    PubMed Central

    Can, Ilknur; Onat, Ahmet Mesut; Aytemir, Kudret; Akdogan, Ali; Ureten, Kemal; Kiraz, Sedat; Ertenli, Ihsan; Tokgozoglu, Lale; Oto, Ali

    2009-01-01

    Systemic scleroderma is a disease that is characterized by excessive fibroblastic activity and collagen deposition in various organs, including the heart. We sought to evaluate the limits of biventricular function as derived noninvasively from pulsed-wave tissue Doppler imaging (TDI) of tricuspid and mitral annular motion in patients who had scleroderma. We enrolled 24 patients with scleroderma (study group; mean age, 49 ± 11 yr; 20 women) and 24 healthy participants (control group; mean age, 51 ± 9 yr; 19 women). Persons with cardiovascular risk factors were excluded. We obtained images by conventional echocardiography and by pulsed-wave TDI, measuring the respective peak systolic velocities (S, Sm) and peak early (E, Em) and late (A, Am) diastolic velocities. Mean Sm, mean Em, and mean Am were averages of the 4 measured sites (anterior, inferior, lateral, and septal). We calculated noninvasive estimates of left ventricular (LV) filling pressure by dividing E velocities (from the mitral inflow) by Em velocities (E/Em ratios). Biventricular regional Sm, regional LV myocardial Em, and ratios of myocardial Em/atrial component velocity (Em/Am) for the LV, and mean Sm, mean Em, and mean Em/mean Am ratios for the LV were significantly lower in the study group. The E/Em ratio was higher in the study group (7.3 ± 2.6 vs 5.2 ± 1.0, P = 0.01). Global LV systolic and diastolic function did not differ between the groups. Tissue Doppler imaging complements conventional echocardiography in detecting subclinical biventricular impairment in patients with scleroderma who have normal global measurements. PMID:19436783

  8. Echocardiography for cardiac resynchronization therapy: recommendations for performance and reporting--a report from the American Society of Echocardiography Dyssynchrony Writing Group endorsed by the Heart Rhythm Society.

    PubMed

    Gorcsan, John; Abraham, Theodore; Agler, Deborah A; Bax, Jeroen J; Derumeaux, Genevieve; Grimm, Richard A; Martin, Randy; Steinberg, Jonathan S; Sutton, Martin St John; Yu, Cheuk-Man

    2008-03-01

    Echocardiography plays an evolving and important role in the care of heart failure patients treated with biventricular pacing, or cardiac resynchronization therapy (CRT). Numerous recent published reports have utilized echocardiographic techniques to potentially aide in patient selection for CRT prior to implantation and to optimized device settings afterwards. However, no ideal approach has yet been found. This consensus report evaluates the contemporary applications of echocardiography for CRT including relative strengths and technical limitations of several techniques and proposes guidelines regarding current and possible future clinical applications. Principal methods advised to qualify abnormalities in regional ventricular activation, known as dyssynchrony, include longitudinal velocities by color-coded tissue Doppler and the difference in left ventricular to right ventricular ejection using routine pulsed Doppler, or interventricular mechanical delay. Supplemental measures of radial dynamics which may be of additive value include septal-to-posterior wall delay using M-mode in patients with non-ischemic disease with technically high quality data, or using speckle tracking radial strain. A simplified post-CRT screening for atrioventricular optimization using Doppler mitral inflow velocities is also proposed. Since this is rapidly changing field with new information being added frequently, future modification and refinements in approach are anticipated to continue.

  9. A new electrocardiogram algorithm for diagnosing loss of ventricular capture during cardiac resynchronisation therapy.

    PubMed

    Ganière, Vincent; Domenichini, Giulia; Niculescu, Viviana; Cassagneau, Romain; Defaye, Pascal; Burri, Haran

    2013-03-01

    The prerequisite for cardiac resynchronization therapy (CRT) is ventricular capture, which may be verified by analysis of the surface electrocardiogram (ECG). Few algorithms exist to diagnose loss of ventricular capture. Electrocardiograms from 126 CRT patients were analysed during biventricular (BV), right ventricular (RV), and left ventricular (LV) pacing. An algorithm evaluating QRS narrowing in the limb leads and increasing negativity in lead I to diagnose changes in ventricular capture was devised, prospectively validated, and compared with two existing algorithms. Performance of the algorithm according to ventricular lead position was also assessed. Our algorithm had an accuracy of 88% to correctly identify the changes in ventricular capture (either loss or gain of RV or LV capture). The algorithm had a sensitivity of 94% and a specificity of 96% with an accuracy of 96% for identifying loss of LV capture (the most clinically relevant change), and compared favourably with the existing algorithms. Performance of the algorithms was not significantly affected by RV or LV lead position. A simple two-step algorithm evaluating QRS width in the limb leads and changes in negativity in lead I can accurately diagnose the lead responsible for intermittent loss of ventricular capture in CRT. This simple tool may be of particular use outside the setting of specialized device clinics.

  10. Spanish Pacemaker Registry. Thirteenth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2015).

    PubMed

    Pombo Jiménez, Marta; Cano Pérez, Óscar; Fidalgo Andrés, María Luisa; Lorente Carreño, Diego; Coma Samartín, Raúl

    2016-12-01

    We describe the results of the analysis of the devices implanted and conveyed to the Spanish Pacemaker Registry in 2015. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. We received information from 111 hospitals, with a total of 12 555 cards, representing 32.1% of all the estimated activity. The use of conventional generators and resynchronization devices was 820 and 73 units per million population, respectively. The mean age of the patients receiving an implantation was 77.7 years, and more than 50% of the devices were implanted in patients over 80 years of age. Overall, 58.6% of the implants and 58.8% of the replacements were performed in men. All of the endocardial leads employed were bipolar, 81.5% had an active fixation system, and 16.5% were compatible with magnetic resonance. Although dual chamber sequential pacing continues to be more widespread, pacing with VVI/R mode is used because up to 23.8% of the patients with sinus node disease are in sinus rhythm, as are 24.1% of those with atrioventricular block. The total use of pacemaker generators in Spain has increased by about 5% with respect to 2014. The majority of the leads implanted are of active fixation, and less than 20% are protected from magnetic resonance. The factors directly related to the selection of pacing mode are age and sex. In around 20% of patients, the choice of the pacing mode could be improved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Sequential processing deficits in schizophrenia: relationship to neuropsychology and genetics.

    PubMed

    Hill, S Kristian; Bjorkquist, Olivia; Carrathers, Tarra; Roseberry, Jarett E; Hochberger, William C; Bishop, Jeffrey R

    2013-12-01

    Utilizing a combination of neuropsychological and cognitive neuroscience approaches may be essential for characterizing cognitive deficits in schizophrenia and eventually assessing cognitive outcomes. This study was designed to compare the stability of select exemplars for these approaches and their correlations in schizophrenia patients with stable treatment and clinical profiles. Reliability estimates for serial order processing were comparable to neuropsychological measures and indicate that experimental serial order processing measures may be less susceptible to practice effects than traditional neuropsychological measures. Correlations were moderate and consistent with a global cognitive factor. Exploratory analyses indicated a potentially critical role of the Met allele of the Catechol-O-methyltransferase (COMT) Val158Met polymorphism in externally paced sequential recall. Experimental measures of serial order processing may reflect frontostriatal dysfunction and be a useful supplement to large neuropsychological batteries. © 2013.

  12. Sequential Processing Deficits in Schizophrenia: Relationship to Neuropsychology and Genetics

    PubMed Central

    Hill, S. Kristian; Bjorkquist, Olivia; Carrathers, Tarra; Roseberry, Jarett E.; Hochberger, William C.; Bishop, Jeffrey R.

    2014-01-01

    Utilizing a combination of neuropsychological and cognitive neuroscience approaches may be essential for characterizing cognitive deficits in schizophrenia and eventually assessing cognitive outcomes. This study was designed to compare the stability of select exemplars for these approaches and their correlations in schizophrenia patients with stable treatment and clinical profiles. Reliability estimates for serial order processing were comparable to neuropsychological measures and indicate that experimental serial order processing measures may be less susceptible to practice effects than traditional neuropsychological measures. Correlations were moderate and consistent with a global cognitive factor. Exploratory analyses indicated a potentially critical role of the Met allele of the Catechol-O-methyltransferase (COMT) Val158Met polymorphism in externally paced sequential recall. Experimental measures of serial order processing may reflect frontostriatal dysfunction and be a useful supplement to large neuropsychological batteries. PMID:24119464

  13. Effects of milrinone and epinephrine or dopamine on biventricular function and hemodynamics in right heart failure after pulmonary regurgitation.

    PubMed

    Hyldebrandt, Janus Adler; Agger, Peter; Sivén, Eleonora; Wemmelund, Kristian Borup; Heiberg, Johan; Frederiksen, Christian Alcaraz; Ravn, Hanne Berg

    2015-09-01

    Right ventricular failure (RVF) secondary to pulmonary regurgitation (PR) impairs right ventricular (RV) function and interrupts the interventricular relationship. There are few recommendations for the medical management of severe RVF after prolonged PR. PR was induced in 16 Danish landrace pigs by plication of the pulmonary valve leaflets. Twenty-three pigs served as controls. At reexamination the effect of milrinone, epinephrine, and dopamine was evaluated using biventricular conductance and pulmonary catheters. Seventy-nine days after PR was induced, RV end-diastolic volume index (EDVI) had increased by 33% (P = 0.006) and there was a severe decrease in the load-independent measurement of contractility (PRSW) (-58%; P = 0.003). Lower cardiac index (CI) (-28%; P < 0.0001), mean arterial pressure (-15%; P = 0.01) and mixed venous oxygen saturation (SvO2) (36%; P < 0.0001) were observed compared with the control group. The interventricular septum deviated toward the left ventricle (LV). Milrinone improved RV-PRSW and CI and maintained systemic pressure while reducing central venous pressure (CVP). Epinephrine and dopamine further improved biventricular PRSW and CI equally in a dose-dependent manner. Systemic and pulmonary pressures were higher in the dopamine-treated animals compared with epinephrine-treated animals. None of the treatments improved stroke volume index (SVI) despite increases in contractility. Strong correlation was detected between SVI and LV-EDVI, but not SVI and biventricular contractility. In RVF due to PR, milrinone significantly improved CI, SvO2, and CVP and increased contractility in the RV. Epinephrine and dopamine had equal inotropic effect, but a greater vasopressor effect was observed for dopamine. SV was unchanged due to inability of both treatments to increase LV-EDVI. Copyright © 2015 the American Physiological Society.

  14. Functional and geometrical interference and interdependency between the right and left ventricle in cor pulmonale: an experimental study on simultaneous measurement of biventricular geometry of acute right ventricular pressure overload.

    PubMed

    Yamashita, H; Onodera, S; Imamoto, T; Obara, A; Tanazawa, S; Takashio, T; Morimoto, H; Inoue, H

    1989-10-01

    To clarify the effects of right ventricular (RV) pressure overload on functional and geometrical interference and interdependency between the right and left ventricle, both ventricular internal diameters were measured by the microcrystal technique during lycopodium induced pulmonary embolization in the dog. By repeated embolization, RV systolic pressure was increased progressively until it reached a peak value of about 60-70 mmHg, then it began to fall. At the same time, the hemodynamics deteriorated progressively resulting in death. During the experiment, gradual leftward displacement of the interventricular septum (IVS) without any change in left ventricular (LV) free wall geometry was observed. In pulmonary embolic shock, which showed a fall in LV pressure to about 60 mmHg and cardiac output to about 40% of control, the leftward displacement of IVS became marked, and the cooperative movement of IVS to LV contraction disappeared. The IVS position during acute RV pressure overload was able to account for the transseptal pressure gradient. The importance of IVS position and motion in cardiac function during acute RV pressure overload was stressed. Furthermore, to establish the theoretical treatment in acute cardiopulmonary resuscitation, ligation of the descending aorta (AoL) or norepinephrine ("N") or isoproterenol ("I") administration were examined in a canine pulmonary embolic shock model. AoL or "N" improved the deteriorated hemodynamics with restoration of biventricular geometry. However, "I" did not restore the biventricular geometry despite the transiently improved hemodynamics, and the experimental animals were unable to survive. These results suggest the importance of the maintainance of systemic pressure for the restoration of failed RV function. Further integrated studies are required to understand biventricular interference and interdependency.

  15. Radiofrequency catheter ablation of idiopathic ventricular arrhythmias originating from intramural foci in the left ventricular outflow tract: efficacy of sequential versus simultaneous unipolar catheter ablation.

    PubMed

    Yamada, Takumi; Maddox, William R; McElderry, H Thomas; Doppalapudi, Harish; Plumb, Vance J; Kay, G Neal

    2015-04-01

    Idiopathic ventricular arrhythmias (VAs) originating from the left ventricular outflow tract (LVOT) sometimes require catheter ablation from the endocardial and epicardial sides for their elimination, suggesting the presence of intramural VA foci. This study investigated the efficacy of sequential and simultaneous unipolar radiofrequency catheter ablation from the endocardial and epicardial sides in treating intramural LVOT VAs. Fourteen consecutive LVOT VAs, which required sequential or simultaneous irrigated unipolar radiofrequency ablation from the endocardial and epicardial sides for their elimination, were studied. The first ablation was performed at the site with the earliest local ventricular activation and best pace map on the endocardial or epicardial side. When the first ablation was unsuccessful, the second ablation was delivered on the other surface. If this sequential unipolar ablation failed, simultaneous unipolar ablation from both sides was performed. The first ablation was performed on the epicardial side in 9 VAs and endocardial side in 5 VAs. The intramural LVOT VAs were successfully eliminated by the sequential (n=9) or simultaneous (n=5) unipolar catheter ablation. Simultaneous ablation was most likely to be required for the elimination of the VAs when the distance between the endocardial and epicardial ablation sites was >8 mm and the earliest local ventricular activation time relative to the QRS onset during the VAs of <-30 ms was recorded at those ablation sites. LVOT VAs originating from intramural foci could usually be eliminated by sequential unipolar radiofrequency ablation and sometimes required simultaneous ablation from both the endocardial and epicardial sides. © 2015 American Heart Association, Inc.

  16. [Initial experience with a new blood pump].

    PubMed

    Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A

    1990-12-01

    A new type of blood pump was tested in calves for 6 hours. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotating on an eccentric shaft, describes a trochoidal path, thus creating a gap seal, the gap measuring a constant 10-35 microns. The pump is driven by a watercooled DC motor. For right ventricular assist, a cannula is inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assists. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 31 at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hours, and returned to 16 mg/dl after 6 hours. From these preliminary results it is concluded that this new rotary blood pump may be suitable as a circulatory assist device.

  17. Rotacor: a new rotary blood pump.

    PubMed

    Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A

    1990-01-01

    A new rotary blood pump was tested in calves for 6 hr. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotates on an eccentric shaft in a trochoidal path, thus creating a gap seal. The pump is driven by a water-cooled DC motor. For right ventricular assist, a cannula was inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assist. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 3 L at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hr, when it started to chop again; after 6 hr it was 16 mg/dl. From these preliminary results it is concluded that this new type of blood pump may be suitable as a circulatory assist device.

  18. Economic Value and Cost-Effectiveness of Cardiac Resynchronization Therapy Among Patients With Mild Heart Failure: Projections From the REVERSE Long-Term Follow-Up.

    PubMed

    Gold, Michael R; Padhiar, Amie; Mealing, Stuart; Sidhu, Manpreet K; Tsintzos, Stelios I; Abraham, William T

    2017-03-01

    This study investigated the cost effectiveness of early cardiac resynchronization therapy (CRT) implantation among patients with mild heart failure (HF). The differential cost effectiveness between CRT using a defibrillator (CRT-Ds) and CRT using a pacemaker (CRT-P) was also assessed. Cardiac resynchronization has been shown to be cost effective in New York Heart Association (NYHA) functional classes III/IV but is less studied in class II HF. The incremental costs of early CRT implementation in mild HF compared with the costs potentially avoided because of delaying disease progression to advanced HF are also unknown. Finally, combined biventricular pacing and defibrillator (CRT-D) devices are more expensive than biventricular pacemakers (CRT-P), but the relative cost effectiveness is controversial. Data from the 5-year follow-up phase of REVERSE (REsynchronization reVErses Remodeling in Systolic Left vEntricular Dysfunction) were used. The economics were evaluated from the U.S. Medicare perspective based on published clinical projections. Probabilistic estimates yielded $8,840/quality-adjusted life year (QALY) gained (95% confidence interval [CI]: $6,705 to $10,804/QALY gained) for CRT-ON versus CRT-OFF (i.e., programmed "ON" or "OFF" at pre-specified post-implantation timings) and $43,678/QALY gained for CRT-D versus CRT-P (95% CI: $35,164 to $53,589/QALY gained) over the patient's lifetime. Results were robust to choice of patient subgroup and alterations of ±10% to key model parameters. An "early" CRT-D class II strategy totaled $95,292 compared with $91,511 for a "late" implantation. An "early" implant offered on average 1.00 year of additional survival for $3,781, resulting in an ICER of $3,795/LY gained. This study demonstrates CRT cost effectiveness in mild HF. The incremental CRT-D costs are justified by the anticipated benefits, despite increased procurement costs and shorter generator longevities. "Early" CRT-D implants have essential cost parity with "late" implants while increasing the patient's survival. (REsynchronization reVErses Remodeling in Systolic Left vEntricular Dysfunction [REVERSE]; NCT00271154). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. The Importance of Purkinje Activation in Long Duration Ventricular Fibrillation

    PubMed Central

    Huang, Jian; Dosdall, Derek J.; Cheng, Kang‐An; Li, Li; Rogers, Jack M.; Ideker, Raymond E.

    2014-01-01

    Background The mechanisms that maintain long duration ventricular fibrillation (LDVF) are unclear. The difference in distribution of the Purkinje system in dogs and pigs was explored to determine if Purkinje activation propagates to stimulate working myocardium (WM) during LDVF and WM pacing. Methods and Results In‐vivo extracellular recordings were made from 1044 intramural plunge and epicardial plaque electrodes in 6 pig and 6 dog hearts. Sinus activation propagated sequentially from the endocardium to the epicardium in dogs but not pigs. During epicardial pacing, activation propagated along the endocardium and traversed the LV wall almost parallel to the epicardium in dogs, but in pigs propagated away from the pacing site approximately perpendicular to the epicardium. After 1 minute of VF, activation rate near the endocardium was significantly faster than near the epicardium in dogs (P<0.01) but not pigs (P>0.05). From 2 to 10 minutes of LDVF, recordings exhibiting Purkinje activations were near the endocardium in dogs (P<0.01) but were scattered transmurally in pigs, and the WM activation rate in recordings in which Purkinje activations were present was significantly faster than the WM activation rate in recordings in which Purkinje activations were absent (P<0.01). In 10 isolated perfused dog hearts, the LV endocardium was exposed and 2 microelectrodes were inserted into Purkinje and adjacent myocardial cells. After 5 minutes of LDVF, mean Purkinje activation rate was significantly faster than mean WM activation rate (P<0.01). Conclusion These extracellular and intracellular findings about activation support the hypothesis that Purkinje activation propagates to stimulate WM during sinus rhythm, pacing, and LDVF. PMID:24584738

  20. Total artificial heart implantation in a young Marfan syndrome patient.

    PubMed

    Rao, Prashant; Keenan, Jack B; Rajab, Taufiek K; Kim, Samuel; Smith, Richard; Amabile, Orazio; Khalpey, Zain

    2018-03-01

    Cardiovascular complications represent the leading cause of morbidity and mortality in patients with Marfan syndrome. Here, we describe a unique case where a total artificial heart was implanted in a young Marfan syndrome woman. A 22-year-old postpartum African American female with Marfan syndrome developed multiple severe valve dysfunction and biventricular failure that was refractory to medical management. She previously had a Bentall procedure for Type A aortic dissection and repair of a Type B dissection. We implanted a total artificial heart with a good outcome. Total artificial heart is a durable option for severe biventricular failure and multiple valvular dysfunction as a bridge to transplant in a young patient with Marfan syndrome.

  1. Biventricular and atrial diastolic function assessment using conventional echocardiography and tissue-Doppler imaging in adults with Marfan syndrome.

    PubMed

    Kiotsekoglou, Anatoli; Moggridge, James C; Bijnens, Bart H; Kapetanakis, Venediktos; Alpendurada, Francisco; Mullen, Michael J; Saha, Samir; Nassiri, Dariush K; Camm, John; Sutherland, George R; Child, Anne H

    2009-12-01

    Previous studies provided evidence about left ventricular systolic and diastolic dysfunction in adults with Marfan syndrome (MFS). However, in the literature, data on right ventricular and bi-atrial diastolic function are limited. We aimed to investigate whether, in the absence of significant valvular disease, diastolic dysfunction is present not only in both ventricles but also in the atrial cavities. Seventy-two adult unoperated MFS patients and 73 controls without significant differences in age, sex, and body surface area from the patient group were studied using two-dimensional, pulsed, and colour-Doppler and tissue-Doppler imaging (TDI). Biventricular early filling measurements were significantly decreased in MFS patients when compared with controls (P < 0.001). Pulsed TDI early filling measurements obtained from five mitral annular regions and over the lateral tricuspid valve corner were significantly reduced in the patient group (P < 0.001). Indices reflecting atrial function at the reservoir, conduit and contractile phases were also significantly decreased in MFS patients (P < 0.001). This study demonstrated significant biventricular diastolic and biatrial systolic and diastolic dysfunction in MFS patients. Our findings suggest that MFS affects diastolic function independently. Diastolic abnormalities could be attributed to fibrillin-1 deficiency and dysregulation of transforming growth factor-beta activity in the cardiac extracellular matrix.

  2. Bi-ventricular finite element model of right ventricle overload in the healthy rat heart.

    PubMed

    Masithulela, Fulufhelo

    2016-11-25

    The recognition of RV overpressure is critical to human life, as this may signify morbidity and mortality. Right ventricle (RV) dysfunction is understood to have an impact on the performance of the left ventricle (LV), but the mechanisms remain poorly understood. It is understood that ventricular compliance has the ability to affect cardiac performance. In this study, a bi-ventricular model of the rat heart was used in preference to other, single-ventricle models. Finite element analysis (FEA) of the bi-ventricular model provides important information on the function of the healthy heart. The passive myocardium was modelled as a nearly incompressible, hyperelastic, transversely isotropic material using finite element (FE) methods. Bi-ventricular geometries of healthy rat hearts reconstructed from magnetic resonance images were imported in Abaqus©. In simulating the normal passive filling of the rat heart, pressures of 4.8 kPa and 0.0098 kPa were applied to the inner walls of the LV and RV respectively. In addition, to simulate the overpressure of the RV, pressures of 2.4 kPa and 4.8 kPa were applied to the endocardial walls of the LV and RV respectively. As boundary conditions, the circumferential and longitudinal displacements at the base were set to zero. The radial displacements at the base were left free. The results show that the average circumferential stress at the mid-wall in the overloaded model increased from 2.8 kPa to 18.2 kPa. The average longitudinal stress increased from 1.5 kPa to 9.7 kPa. Additionally, in the radial direction, the average stress increased from 0.1 kPa to 0.6 kPa in the mid-wall. The average circumferential strain was found to be 0.138 and 0.100 on the endocardium of the over pressured and healthy model respectively. The average circumferential stress at the epicardium, mid-wall and endocardium in the case of a normal heart is 10 times lower than in the overloaded heart model. The finite analysis method is able to provide insights into the behaviour of the over pressured model (myocardium). In the overloaded model the high stresses and strains were observed on the septal wall. The bi-ventricular model was shown to provide useful information relating to the over pressured ventricle. The possible heart dysfunction may be attributable to high stress and strain in the over pressured heart.

  3. The Infant with Aortic Arch Hypoplasia and Small Left Heart Structures: Echocardiographic Indices of Mitral and Aortic Hypoplasia Predicting Successful Biventricular Repair.

    PubMed

    Plymale, Jennifer M; Frommelt, Peter C; Nugent, Melodee; Simpson, Pippa; Tweddell, James S; Shillingford, Amanda J

    2017-08-01

    In infants with aortic arch hypoplasia and small left-sided cardiac structures, successful biventricular repair is dependent on the adequacy of the left-sided structures. Defining accurate thresholds of echocardiographic indices predictive of successful biventricular repair is paramount to achieving optimal outcomes. We sought to identify pre-operative echocardiographic indices of left heart size that predict intervention-free survival in infants with small left heart structures undergoing primary aortic arch repair to establish biventricular circulation (BVC). Infants ≤2 months undergoing aortic arch repair from 1999 to 2010 with aortic and/or mitral valve hypoplasia, (Z-score ≤-2) were included. Pre-operative and follow-up echocardiograms were reviewed. Primary outcome was successful biventricular circulation (BVC), defined as freedom from death, transplant, or single ventricular conversion at 1 year. Need for catheter based or surgical re-intervention (RI), valve annular growth, and significant late aortic or mitral valve obstruction were additional outcomes. Fifty one of 73 subjects (79%) had successful BVC and were free of RI at 1 year. Seven subjects failed BVC; four of those died. The overall 1 year survival for the cohort was 95%. Fifteen subjects underwent a RI but maintained BVC. In univariate analysis, larger transverse aorta (p = 0.006) and aortic valve (p = 0.02) predicted successful BVC without RI. In CART analysis, the combination of mitral valve (MV) to tricuspid valve (TV) ratio ≤0.66 with an aortic valve (AV) annulus Z-score ≤-3 had the greatest power to predict BVC failure (sensitivity 71%, specificity 94%). In those with successful BVC, the combination of both AV and MV Z-score ≤-2.5 increased the odds of RI (OR 3.8; CI 1.3-11.4). Follow-up of non-RI subjects revealed improvement in AV and MV Z-score (median AV annulus changed over time from -2.34 to 0.04 (p < 0.001) and MV changed from -2.88 to -1.41 (p < 0.001), but residual mitral valve stenosis and aortic arch obstruction were present in one-third of subjects. In this cohort of infants requiring initial aortic arch repair with concomitant small left heart structures, successful BVC can be predicted from combined echocardiographic indices. In this complex population, 1 year survival is high, but the need for RI and the presence of residual lesions are common.

  4. A comparative analysis between the effects of galactose and glucose supplementation on endurance performance.

    PubMed

    Macdermid, Paul W; Stannard, Stephen; Rankin, Dean; Shillington, David

    2012-02-01

    To determine beneficial effects of short-term galactose (GAL) supplementation over a 50:50 glucose-maltodextrin (GLUC) equivalent on self-paced endurance cycling performance. On 2 separate occasions, subjects performed a 100-km self-paced time trial (randomized and balanced order). This was interspersed with four 1-km and four 4-km maximal efforts reflecting the physical requirements of racing. Before each trial 38±3 g of GAL or GLUC was ingested in a 6% concentrate fluid form 1 hr preexercise and then during exercise at a rate of 37±3 g/hr. Performance variables were recorded for all 1- and 4-km efforts, all interspersed intervals, and the total 100-km distance. Noninvasive indicators of work intensity (heart rate [HR] and rating of perceived exertion) were also recorded. Times taken to complete the 100-km performance trial were 8,298±502 and 8,509±578 s (p=.132), with mean power outputs of 271±37 and 256±45 W (p=.200), for GAL and GLUC, respectively. Mean HR did not differ (GAL 157±7 and GLUC 157±7 beats/min, p=.886). A main effect of carbohydrate (CHO) type on time to complete 4-km efforts occurred, with no CHO Type×Effort Order interaction observed. No main effect of CHO type or interaction of CHO Type×Sequential Order occurred for 1-km efforts. A 6% GAL drink does not enhance performance time during a self-paced cycling performance trial in highly trained endurance cyclists compared with a formula typically used by endurance athletes but may improve the ability to produce intermediate self-paced efforts.

  5. Differentiation of ventricular and supraventricular tachycardias based on the analysis of the first postpacing interval after sequential anti-tachycardia pacing in implantable cardioverter-defibrillator patients.

    PubMed

    Arenal, Angel; Ortiz, Mercedes; Peinado, Rafael; Merino, Jose L; Quesada, Aurelio; Atienza, Felipe; Alberola, Arcadio García; Ormaetxe, Jose; Castellanos, Eduardo; Rodriguez, Juan C; Pérez, Nicasio; García, Javier; Boluda, Luis; del Prado, Mario; Artés, Antonio

    2007-03-01

    Current discrimination algorithms do not completely avoid inappropriate tachycardia detection. This study analyzes the discrimination capability of the changes of the first postpacing interval (FPPI) after successive bursts of anti-tachycardia pacing (ATP) trains in implantable cardioverter-defibrillator (ICD)-recorded tachycardias. We included 50 ICD patients in this prospective study. We hypothesized that the FPPI variability (FPPIV) when comparing bursts with different numbers of beats would be shorter in ventricular tachycardias (VTs) compared with supraventricular tachycardias (SVTs). The ATP (5-10 pulses, 91% of tachycardia cycle length) was programmed for tachycardias >240 ms. Anti-tachycardia pacing was delivered during 37 sinus tachycardias (STs) in an exercise test, 96 induced VTs in an electrophysiological study, and 198 spontaneous episodes (144 VTs and 54 SVTs). The FPPI remained stable after all ATP bursts in VT but changed continuously in SVT; when comparing bursts of 5 and 10 pulses, the FPPIV was shorter in VT (34 +/- 65 vs.138 +/- 69, P<.0001, in all T and 12 +/- 20 vs. 138 +/- 69, P<.0001, in T>or=320 ms) than in SVT. In T>or=320 ms an FPPIV

  6. Current Surgical Outcomes of Congenital Heart Surgery for Patients With Down Syndrome in Japan.

    PubMed

    Hoashi, Takaya; Hirahara, Norimichi; Murakami, Arata; Hirata, Yasutaka; Ichikawa, Hajime; Kobayashi, Junjiro; Takamoto, Shinichi

    2018-01-25

    Current surgical outcomes of congenital heart surgery for patients with Down syndrome are unclear.Methods and Results:Of 29,087 operations between 2008 and 2012 registered in the Japan Congenital Cardiovascular Surgery Database (JCCVSD), 2,651 were carried out for patients with Down syndrome (9%). Of those, 5 major biventricular repair procedures [ventricular septal defect repair (n=752), atrioventricular septal defect repair (n=452), patent ductus arteriosus closure (n=184), atrial septal defect repair (n=167), tetralogy of Fallot (TOF) repair (n=108)], as well as 2 major single ventricular palliations [bidirectional Glenn (n=21) and Fontan operation (n=25)] were selected and their outcomes were compared. The 90-day and in-hospital mortality rates for all 5 major biventricular repair procedures and bidirectional Glenn were similarly low in patients with Down syndrome compared with patients without Down syndrome. On the other hand, mortality after Fontan operation in patients with Down syndrome was significantly higher than in patients without Down syndrome (42/1,558=2.7% vs. 3/25=12.0%, P=0.005). Although intensive management of pulmonary hypertension is essential, analysis of the JCCVSD revealed favorable early prognostic outcomes after 5 major biventricular procedures and bidirectional Glenn in patients with Down syndrome. Indication of the Fontan operation for patients with Down syndrome should be carefully decided.

  7. Is hydrotherapy an appropriate form of exercise for elderly patients with biventricular systolic heart failure?

    PubMed Central

    Sveälv, Bente Grüner; Täng, Margareta Scharin; Cider, Åsa

    2012-01-01

    Hydrotherapy (exercise in warm water) is considered to be a safe and beneficial method to use in the rehabilitation of stable heart failure patients, but there is little information on the effect of the increased venous return and enhanced preload in elderly patients with biventricular heart failure. We present a case of an elderly man who was recruited to participate in a hydrotherapy study. We compared echocardiographic data during warm water immersion with land measurements, and observed increases in stroke volume from 32 mL (land) to 42 mL (water), left ventricular ejection fraction from 22% to 24%, left ventricular systolic velocity from 4.8 cm/s to 5.0 cm/s and left atrioventricular plane displacement from 2.1 mm to 2.2 mm. By contrast, right ventricular systolic velocity decreased from 11.2 cm/s to 8.4 cm/s and right atrioventricular plane displacement from 8.1 mm to 4.7 mm. The tricuspid pressure gradient rose from 18 mmHg on land to 50 mmHg during warm water immersion. Thus, although left ventricular systolic function was relatively unaffected during warm water immersion, we observed a decrease in right ventricular function with an augmented right ventricular pressure. We recommend further investigations to observe the cardiac effect of warm water immersion on patients with biventricular systolic heart failure and at risk of elevated right ventricular pressure. PMID:23341846

  8. Churg-Strauss syndrome associated with rapid deterioration of left ventricular diastolic dysfunction and conduction disturbance.

    PubMed

    Chin, Jung Yeon; Yi, Jeong Eun; Youn, Ho-Joong

    2013-10-01

    Cardiac involvement in Churg-Strauss syndrome (CSS) is a major cause of mortality. Here we report a case of a 75-year-old woman with eosinophilic endomyocarditis due to CSS. An electrocardiogram showed intraventricular conduction delay, and echocardiography showed an impaired relaxation pattern and biventricular apical thickening. Magnetic resonance imaging revealed subendocardial delayed enhancement with biventricular apical thrombi. Endomyocardial biopsy showed perivascular eosinophilic infiltration. Despite resolution of the hypereosinophilia after steroid therapy, her left ventricular (LV) diastolic function worsened into a restrictive pattern and she died with a ventricular escape rhythm on her 14th day in the hospital. This case is unusual in that there was rapid progression of the LV diastolic dysfunction and conduction disturbance due to CSS. © 2013, Wiley Periodicals, Inc.

  9. Machines versus medication for biventricular heart failure: focus on the total artificial heart.

    PubMed

    Arabia, Francisco A; Moriguchi, Jaime D

    2014-09-01

    The medical/surgical management of advanced heart failure has evolved rapidly over the last few decades. With better understanding of heart failure pathophysiology, new pharmacological agents have been introduced that have resulted in improvements in survival. For those patients that fail to improve, mechanical circulatory support with left ventricular assist devices and total artificial hearts (TAHs) have served as a beneficial bridge to transplantation. The TAH has continued to play a significant role as a bridge to transplantation in patients with biventricular failure and more selected indications that could not be completely helped with left ventricular assist devices. Improved survival with the TAH has resulted in more patients benefiting from this technology. Improvements will eventually lead to a totally implantable device that will permanently replace the failing human heart.

  10. Do implantable cardioverter defibrillators improve survival in patients with severe left ventricular systolic dysfunction after coronary artery bypass graft surgery?

    PubMed

    Fazal, Iftikhar A; Bates, Matthew G D; Matthews, Iain G; Turley, Andrew J

    2011-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether implantable cardioverter defibrillators (ICD) improve survival in patients with severe left ventricular systolic dysfunction (LVSD) after coronary artery bypass graft (CABG) surgery. ICDs are designed to terminate potentially fatal cardiac tachyarrhythmias. A right ventricular lead is mandatory for detection, pacing and defibrillation capabilities. Dual chamber ICDs have an additional right atrial lead and are used for patients with conventional atrioventricular pacing indications. More sophisticated, biventricular devices exist to provide cardiac resynchronisation therapy (CRT) in addition to defibrillation (CRT-D). ICDs have been extensively investigated in patients with LVSD post myocardial infarction and in patients with non-ischaemic cardiomyopathy for both secondary prevention (history of ventricular arrhythmias) and primary prevention (deemed high risk for ventricular arrhythmias). This best evidence topic aims to review the evidence and its applicability to patients post CABG. Nine hundred and sixteen papers were identified using the search method outlined. Eight randomised controlled trials, two meta-analyses, and one non-randomised trial, in addition to international guidelines presented the best evidence to answer the clinical question. The current evidence base and guidelines suggest that ICDs should be considered for all patients with LVSD [ejection fraction (EF) ≤30-40%] receiving optimal pharmacological management, who are ≥40 days post MI [four weeks for National Institute for Health and Clinical Excellence (NICE)] and in New York Heart Association (NYHA) class I-III. UK NICE guidelines require in addition; non-sustained ventricular tachycardia (NSVT) on a Holter monitor and inducible ventricular tachycardia at electrophysiological study for EF between 30 and 35%; or a QRS >120 ms if EF <30%. The North American guidelines recommend EF <30% as a threshold for those with NYHA class I symptoms. The evidence is applicable to patients post CABG, provided all the other criteria are met. European Society of Cardiology (ESC) guidelines recommend waiting at least three months (consensus opinion) after revascularisation prior to assessment for an ICD, to allow time for potential recovery of ventricular function.

  11. Reduced capacity of cardiac efferent sympathetic neurons to release noradrenaline and modify cardiac function in tachycardia-induced canine heart failure.

    PubMed

    Cardinal, R; Nadeau, R; Laurent, C; Boudreau, G; Armour, J A

    1996-09-01

    To investigate the capacity of efferent sympathetic neurons to modulate the failing heart, stellate ganglion stimulation was performed in dogs with biventricular heart failure induced by rapid ventricular pacing (240 beats/min) for 4-6 weeks. Less noradrenaline was released from cardiac myoneural junctions into coronary sinus blood in response to left stellate ganglion stimulation in anesthetized failing heart preparations (582 pg/mL, lower and upper 95% confidence intervals of 288 and 1174 pg/mL, n = 19) compared with healthy heart preparations (6391 pg/mL, 95% confidence intervals of 4180 and 9770 pg/mL, n = 14; p < 0.001). There was substantial adrenaline extraction by failing hearts (49 +/- 6%), although it was slightly lower than in healthy heart preparations (65 +/- 9%, p = 0.055). In contrast with healthy heart preparations, no net release of adrenaline occurred during stellate ganglion stimulation in any of the failing heart preparations, and ventricular tissue levels of adrenaline fell below the sensitivity limit of the HPLC technique. In failing heart preparations, maximal electrical stimulation of right or left stellate ganglia resulted in minimal augmentation of left ventricular intramyocardial (17%) and chamber (12%) systolic pressures. These indices were augmented by 145 and 97%, respectively, following exogenous noradrenaline administration. Thus, the cardiac efferent sympathetic neurons' reduced capacity to release noradrenaline and modify cardiac function can contribute to reduction of sympathetic support to the failing heart.

  12. Right ventricle myectomy.

    PubMed

    Borisov, Konstantin V

    2017-07-01

    Right ventricular (RV) hypertrophy is common in patients with hypertrophic cardiomyopathy (HCM), and is associated with more severe disease. Conventional surgical strategies such as the traditional Morrow procedure pose a particularly high risk to patients with severe hypertrophy and RV obstruction, for whom the most appropriate therapeutic approach has not yet been established. We have proposed a new technique for surgical correction in patients with hypertrophic obstructive cardiomyopathy and severe hypertrophy, which involves approaching the area of obstruction by entering through the conal part of the RV. This novel technique provides effective elimination of biventricular obstruction and the precise removal of the areas of septal fibrosis in patients with hypertrophic obstructive cardiomyopathy. The current literature review analyzes the indications and various techniques for performing a RV myectomy, and presents the results of follow-up assessments in patients with biventricular obstruction and severe hypertrophy.

  13. Personal digital assistant-based, internet-enabled remote communication system for a wearable pneumatic biventricular assist device.

    PubMed

    Nam, Kyoung Won; Lee, Jung Joo; Hwang, Chang Mo; Choi, Seong Wook; Son, Ho Sung; Sun, Kyung

    2007-11-01

    Currently, personal mobile communication devices have become quite common, and the applications of such devices have expanded quickly. Remote communication systems might be employed for the telemonitoring of patients or the operating status of their medical devices. In this article, we describe the development of a mobile-based artificial heart telemanagement system for use in a wearable extracorporeal pneumatic biventricular assist device, which is capable of telemonitoring and telecontrolling the operating status of the ventricular assist device from any site. The system developed herein utilized small mobile phones for the client device and adopted a standard transmission control protocol/Internet protocol communication protocol for the purposes of telecommunication. The results of in vitro and animal experiments showed that the telemanagement system developed herein operated in accordance with the desired parameters.

  14. White Matter Volume Predicts Language Development in Congenital Heart Disease

    PubMed Central

    Rollins, Caitlin K.; Asaro, Lisa A.; Akhondi-Asl, Alireza; Kussman, Barry D.; Rivkin, Michael J.; Bellinger, David C.; Warfield, Simon K.; Wypij, David; Newburger, Jane W.; Soul, Janet S.

    2016-01-01

    Objective To determine whether brain volume is reduced at one year and whether these volumes are associated with neurodevelopment in biventricular congenital heart disease (CHD) repaired in infancy. Study design Infants with biventricular CHD (n = 48) underwent brain magnetic resonance imaging (MRI) and neurodevelopmental testing with the Bayley Scales of Infant Development-II (BSID-II) and the MacArthur-Bates Communicative Development Inventories (CDI) at one year. A multi-template based probabilistic segmentation algorithm was applied to volumetric MRI data. We compared volumes with those of 13 healthy control infants of comparable ages. In the CHD group, we measured Spearman correlations between neurodevelopmental outcomes and the residuals from linear regression of the volumes on corrected chronological age at MRI and sex. Results Compared with controls, CHD infant had reductions of 54 mL in total brain (P = 0.009), 40 mL in cerebral white matter (P < 0.001), and 1.2 mL in brainstem (P = 0.003) volumes. Within the CHD group, brain volumes were not correlated with BSID-II scores but did correlate positively with CDI language development. Conclusion Infants with biventricular CHD show total brain volume reductions at one year of age, driven by differences in cerebral white matter. White matter volume correlates with language development, but not broader developmental indices. These findings suggest that abnormalities in white matter development detected months after corrective heart surgery may contribute to language impairment. Trial registration ClinicalTrials.gov: NCT00006183 PMID:27837950

  15. The future of mechanical circulatory support for advanced heart failure.

    PubMed

    Marinescu, Karolina K; Uriel, Nir; Adatya, Sirtaz

    2016-05-01

    Mechanical circulatory support (MCS) has become the main focus of heart replacement therapy for end stage heart failure patients. Advances in technology are moving towards miniaturization, biventricular support devices, complete internalization, improved hemocompatibility profiles, and responsiveness to cardiac loading conditions. This review will discuss the recent advances and investigational devices in MCS for advanced heart failure. The demand for both short-term and long-term durable devices for advanced heart failure is increasing. The current devices are still fraught with an unacceptably high incidence of gastrointestinal bleeding and thromboembolic and infectious complications. New devices are on the horizon focusing on miniaturization, versatility for biventricular support, improved hemocompatibility, use of alternate energy sources, and incorporation of continuous hemodynamic monitoring. The role for MCS in advanced heart replacement therapy is steadily increasing. With the advent of newer generation devices on the horizon, the potential exists for MCS to surpass heart transplantation as the primary therapy for advanced heart failure.

  16. Biventricular hypertrophy and heart failure as initial presentation of Cushing's disease

    PubMed Central

    Hey, Thomas Morris; Dahl, Jordi Sanchez; Brix, Thomas Heiberg; Søndergaard, Eva Vad

    2013-01-01

    We present a unique case of a 32-year-old woman with severe biventricular hypertrophy and acute heart failure with reduced left ventricular ejection fraction of 25–30% due to Cushing's disease. The patient was admitted to a specialised cardiac unit and treated with conventional therapy against heart failure. The department of endocrinology was consulted because of clinical suspicion of Cushing's syndrome. Initial biochemistry indicated the presence of adrenocorticotropic hormone (ACTH) dependent Cushing's syndrome and a dexamethasone suppression test confirmed the diagnosis. A cerebral MRI scan revealed a pituitary adenoma and a sinus petrosus inferior catheterisation confirmed increased production of ACTH from the pituitary. The patient was referred to the neurosurgical department and the adenoma was successfully removed by transsphenoidalic catheterisation and ablation. Five months following the initial hospitalisation the patient was nearly in full recovery with respect to her cardiac function and biochemically there were no signs of Cushing's syndrome. PMID:24186856

  17. Visual narrative structure.

    PubMed

    Cohn, Neil

    2013-04-01

    Narratives are an integral part of human expression. In the graphic form, they range from cave paintings to Egyptian hieroglyphics, from the Bayeux Tapestry to modern day comic books (Kunzle, 1973; McCloud, 1993). Yet not much research has addressed the structure and comprehension of narrative images, for example, how do people create meaning out of sequential images? This piece helps fill the gap by presenting a theory of Narrative Grammar. We describe the basic narrative categories and their relationship to a canonical narrative arc, followed by a discussion of complex structures that extend beyond the canonical schema. This demands that the canonical arc be reconsidered as a generative schema whereby any narrative category can be expanded into a node in a tree structure. Narrative "pacing" is interpreted as a reflection of various patterns of this embedding: conjunction, left-branching trees, center-embedded constituencies, and others. Following this, diagnostic methods are proposed for testing narrative categories and constituency. Finally, we outline the applicability of this theory beyond sequential images, such as to film and verbal discourse, and compare this theory with previous approaches to narrative and discourse. Copyright © 2012 Cognitive Science Society, Inc.

  18. White Matter Volume Predicts Language Development in Congenital Heart Disease.

    PubMed

    Rollins, Caitlin K; Asaro, Lisa A; Akhondi-Asl, Alireza; Kussman, Barry D; Rivkin, Michael J; Bellinger, David C; Warfield, Simon K; Wypij, David; Newburger, Jane W; Soul, Janet S

    2017-02-01

    To determine whether brain volume is reduced at 1 year of age and whether these volumes are associated with neurodevelopment in biventricular congenital heart disease (CHD) repaired in infancy. Infants with biventricular CHD (n = 48) underwent brain magnetic resonance imaging (MRI) and neurodevelopmental testing with the Bayley Scales of Infant Development-II and the MacArthur-Bates Communicative Development Inventories at 1 year of age. A multitemplate based probabilistic segmentation algorithm was applied to volumetric MRI data. We compared volumes with those of 13 healthy control infants of comparable ages. In the group with CHD, we measured Spearman correlations between neurodevelopmental outcomes and the residuals from linear regression of the volumes on corrected chronological age at MRI and sex. Compared with controls, infants with CHD had reductions of 54 mL in total brain (P = .009), 40 mL in cerebral white matter (P <.001), and 1.2 mL in brainstem (P = .003) volumes. Within the group with CHD, brain volumes were not correlated with Bayley Scales of Infant Development-II scores but did correlate positively with MacArthur-Bates Communicative Development Inventory language development. Infants with biventricular CHD show total brain volume reductions at 1 year of age, driven by differences in cerebral white matter. White matter volume correlates with language development, but not broader developmental indices. These findings suggest that abnormalities in white matter development detected months after corrective heart surgery may contribute to language impairment. ClinicalTrials.gov: NCT00006183. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. The Role of Echocardiography in the Optimization of Cardiac Resynchronization Therapy: Current Evidence and Future Perspectives.

    PubMed

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Athanasiou, Antonios; Livanis, Efthimios; Voudris, Vassilis

    2017-01-01

    Cardiac resynchronization therapy (CRT) has become a mainstay in the management of heart failure. Up to one-third of patients who received resynchronization devices do not experience the full benefits of CRT. The clinical factors influencing the likelihood to respond to the therapy are wide QRS complex, left bundle branch block, female gender, non-ischaemic cardiomyopathy (highest responders), male gender, ischaemic cardiomyopathy (moderate responders) and narrow QRS complex, non-left bundle branch block (lowest, non-responders). This review provides a conceptual description of the role of echocardiography in the optimization of CRT. A literature survey was performed using PubMed database search to gather information regarding CRT and echocardiography. A total of 70 studies met selection criteria for inclusion in the review. Echocardiography helps in the initial selection of the patients with dyssynchrony, which will benefit the most from optimal biventricular pacing and provides a guide to left ventricular (LV) lead placement during implantation. Different echocardiographic parameters have shown promise and can offer the possibility of patient selection, response prediction, lead placement optimization strategies and optimization of device configurations. LV ejection fraction along with specific electrocardiographic criteria remains the cornerstone of CRT patient selection. Echocardiography is a non-invasive, cost-effective, highly reproducible method with certain limitations and accuracy that is affected by measurement errors. Echocardiography can assist with the identification of the appropriate electromechanical substrate of CRT response and LV lead placement. The targeted approach can improve the haemodynamic response, as also the patient-specific parameters estimation.

  20. The Role of Echocardiography in the Optimization of Cardiac Resynchronization Therapy: Current Evidence and Future Perspectives

    PubMed Central

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Athanasiou, Antonios; Livanis, Efthimios; Voudris, Vassilis

    2017-01-01

    Background: Cardiac resynchronization therapy (CRT) has become a mainstay in the management of heart failure. Up to one-third of patients who received resynchronization devices do not experience the full benefits of CRT. The clinical factors influencing the likelihood to respond to the therapy are wide QRS complex, left bundle branch block, female gender, non-ischaemic cardiomyopathy (highest responders), male gender, ischaemic cardiomyopathy (moderate responders) and narrow QRS complex, non-left bundle branch block (lowest, non-responders). Objective: This review provides a conceptual description of the role of echocardiography in the optimization of CRT. Method: A literature survey was performed using PubMed database search to gather information regarding CRT and echocardiography. Results: A total of 70 studies met selection criteria for inclusion in the review. Echocardiography helps in the initial selection of the patients with dyssynchrony, which will benefit the most from optimal biventricular pacing and provides a guide to left ventricular (LV) lead placement during implantation. Different echocardiographic parameters have shown promise and can offer the possibility of patient selection, response prediction, lead placement optimization strategies and optimization of device configurations. Conclusion: LV ejection fraction along with specific electrocardiographic criteria remains the cornerstone of CRT patient selection. Echocardiography is a non-invasive, cost-effective, highly reproducible method with certain limitations and accuracy that is affected by measurement errors. Echocardiography can assist with the identification of the appropriate electromechanical substrate of CRT response and LV lead placement. The targeted approach can improve the haemodynamic response, as also the patient-specific parameters estimation. PMID:29387277

  1. [Cardiac resynchronization therapy for heart failure - from experimental pacing to evidence-based therapy].

    PubMed

    Götze, S; Butter, C; Fleck, E

    2006-01-01

    Within the last decade, cardiac resynchronization therapy (CRT) has become an evidence-based cornerstone for a subset of patients with chronic heart failure. For those, who suffer from ischemic or non-ischemic cardiomyopathies at NYHA III or IV, have sinus rhythm, a left bundle branch block and a left ventricular ejection fraction below 35%, CRT has evolved as an important treatment option with promising results. Numerous studies have shown that in these patients pacemaker-mediated correction of intra- and interventicular conduction disturbances can improve not only clinical symptoms, exercise tolerance and the frequency of hospitalizations, but even more important the overall mortality. These clinical results are due to several functional aspects. In the failing heart characteristic intra- and interventricular alterations in electrical conduction result in mechanical asynchrony that leads to an abnormal contraction of the left ventricle with delayed activation of the lateral wall, a paradoxical septal movement, a reduced diastolic filling and a mitral regurgitation due to dyssynchrony of papillary muscle activation. It is conceivable that these functional changes have fatal consequences for the failing heart. AV-optimized left- or biventricular stimulation by modern pacemakers can correct the pathological dyssynchrony, thereby improving cardiac function and clinical outcome in these patients. Although tremendous progress in cardiac resynchronization therapy has been made during the last decade, a couple of questions still need to be resolved. Critical issues are the identification of patients, who will predictably benefit from CRT, the value of CRT-pacemakers versus CRT-ICDs, and the usefullness of CRT in patients with atrial fibrillation.

  2. Structural pathways and prevention of heart failure and sudden death.

    PubMed

    Pacifico, Antonio; Henry, Philip D

    2003-07-01

    We review the macroscopic and microscopic anatomy of myocardial disease associated with heart failure (HF) and sudden cardiac death (SCD) and focus on the prevention of SCD in light of its structural pathways. Compared to patients without SCD, patients with SCD exhibit 5- to 6-fold increases in the risks of ventricular arrhythmias and SCD. Epidemiologically, left ventricular hypertrophy by ECG or echocardiography acts as a potent dose-dependent SCD predictor. Dyslipidemia, a coronary disease risk factor, independently predicts echocardiographic hypertrophy. In adult SCD autopsy studies, increases in heart weight and severe coronary disease are constant findings, whereas rates of acute coronary thrombi vary remarkably. The microscopic myocardial anatomy of SCD is incompletely defined but may include prevalent changes of advanced myocardial disease, including cardiomyocyte hypertrophy, cardiomyocyte apoptosis, fibroblast hyperplasia, diffuse and focal matrix protein accumulation, and recruitment of inflammatory cells. Hypertrophied cardiomyocytes express "fetospecific" genetic programs that can account for acquired long QT physiology with risk for polymorphic ventricular arrhythmias. Structural heart disease associated with HF and high SCD risk is causally related to an up-regulation of the adrenergic renin-angiotensin-aldosterone pathway. In outcome trials, suppression of this pathway with combinations of beta-blockers, angiotensin-converting enzyme inhibitors, angiotensin-II receptor blockers, and mineralocorticoid receptor blockers have achieved substantial total mortality and SCD reductions. Contrarily, trials with ion channel-active agents that are not known to reduce structural heart disease have failed to reduce these risks. Device therapy effectively prevents SCD, but whether biventricular pacing-induced remodeling decreases left ventricular mass remains uncertain.

  3. Time Course of Electrical Remodeling of Native Conduction After Cardiac Resynchronization Therapy and Its Impact on Clinical Outcome.

    PubMed

    Cvijić, Marta; Žižek, David; Antolič, Bor; Zupan, Igor

    2017-03-01

    Cardiac resynchronization therapy (CRT) induces structural and electrical remodeling (ER) in heart failure (HF) patients. Our aim was to assess time course of ER of native conduction and mechanical remodeling after CRT and impact of CRT-induced ER on clinical outcome. We prospectively included 62 patients (aged 66 ± 10 years). Echocardiographic and ECG parameters were measured at baseline and 1, 3, 6, 9, and 12 months after implantation. Biventricular pacing was temporary inhibited during each follow-up to record intrinsic ECG. ER was defined as a decrease in native pre-implantation QRS duration ≥10 ms. During follow-up HF hospitalizations, cardiovascular death and transplantation (combined end point) were recorded. There were significant changes in intrinsic ECG parameters during follow-up; the narrowing of QRS duration was already observed after 1 month (median 185 ms [interquartile range (IQR) 175-194] vs 180 ms [170-194]; P < .001). Left ventricular (LV) volumes decreased only after 3 months of CRT (median end-systolic volume 167 mL [137-206] vs 140 mL [112-196]; P < .001). Only patients with ER (n = 24) exhibited significant mechanical remodeling and showed superior survival free from the combined end point compared with patients without ER (log-rank P = .028). Electrical remodeling of native conduction precedes detectable left ventricular structural changes after CRT. ER of native conduction is associated with better clinical outcome following CRT. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Successful support of biventricular heart failure patients by new EXCOR® Adult pumps with bileaflet valves: a prospective study.

    PubMed

    Schmack, Bastian; Weymann, Alexander; Ruschitzka, Frank; Autschbach, Rüdiger; Raake, Philip W; Jurrmann, Nadine; Menon, Ares K; Karck, Matthias; Wilhelm, Markus J; Ruhparwar, Arjang

    2018-05-01

    The Berlin Heart EXCOR ® Adult biventricular assist device (BiVAD) is an approved mechanical circulatory support for patients with end-stage biventricular heart failure. In this prospective post-market clinical follow-up study, we present the first clinical experience of the new EXCOR ® Adult pump with bileaflet (BL) valves in Europe. After CE-mark approval in August 2014, a total of 12 patients were enrolled with a mean age of 44 years ± 11 (range 21-58 years). The majority of patients (n = 11) were in INTERMACS level 1 or 2. Eight patients had a median pre-operative extracorporeal life support (ECLS) of 6 days (range 1-37 days). Primary end point was survival, either to heart transplantation (HTx), recovery or alive at 12 months on device, whichever occurred first. Secondary end point was the number of adverse events throughout EXCOR ® BiVAD support. Median support time up to last follow-up on EXCOR ® BiVAD device was 248 days (range 57-381 days) and patient survival at 1 year was 92%. Half of the EXCOR ® BiVAD patients (n = 6) were transplanted and five patients were still on support at 1 year post-implantation. Complications during EXCOR ® BiVAD support were thoracic bleeding, exit site infection and ischemic cerebrovascular incidents in three cases, respectively. The new EXCOR ® Adult pump with BL provides pulsatile high cardiac output with excellent outcome and successful bridging to HTx, particularly in critically ill patients with INTERMACS level 1 or 2 at the time of implantation.

  5. Biventricular non-compaction with predominant right ventricular involvement, reduced left ventricular systolic and diastolic function, and pulmonary hypertension in a Hispanic male.

    PubMed

    Said, Sarmad; Cooper, Chad J; Quevedo, Karla; Rodriguez, Emmanuel; Hernandez, German T

    2013-01-01

    Male, 22 FINAL DIAGNOSIS: Cardiomyopathy Symptoms: Shortness of breath • dispnoea • chest discomfort - Clinical Procedure: Echocardiogram • cardiac MRI Specialty: Cardiology. Challenging differential diagnosis. Non-compaction cardiomyopathy (NCM) is a rare congenital cardiomyopathy characterized by increased trabeculation in one or more segments of the ventricle. The left ventricle is most commonly affected. However, biventricular involvement or right ventricle predominance has also been described. Clinical features of NCM are non-specific and can range from being asymptomatic to symptoms of congestive heart failure, arrhythmia, and systemic thromboembolism. 22-year-old Hispanic male presented with two month history of chest discomfort. Laboratory workup revealed an elevated brain-natriuretic-peptide of 1768 pg/ml. ECG and chest x-ray was nonspecific. Transthoracic echocardiogram revealed prominent trabeculae and spongiform appearance of the left ventricle (LV) with an ejection-fraction of 15-20%; 5 of 9 segments of the LV were trabeculated with deep intertrabecular recesses also involving the right ventricle (RV) with demonstrated blood flow in these recesses on color-doppler. The biventricular spongiform appearance was morphologically suggestive for NCM with involvement of the RV. Confirmatory cardiac MRI was performed, demonstrating excessive trabeculation of the left-ventricular apex and mid-ventricular segments. Hypertrabecularion was exhibited at the apical and lateral wall of the RV. Cardiac catheterization showed an intact cardiac vessel system. The patient was discharged on heart failure treatment and was placed on the heart transplantation list. NCM is a unique disorder resulting in serious and severe complications. The majority of the reported cases describe the involvement of the left ventricle. However, the right ventricle should be taken into careful consideration. The early diagnosis may help to increase the event-free survival.

  6. Effects of milrinone and epinephrine or dopamine on biventricular function and hemodynamics in an animal model with right ventricular failure after pulmonary artery banding.

    PubMed

    Hyldebrandt, Janus Adler; Sivén, Eleonora; Agger, Peter; Frederiksen, Christian Alcaraz; Heiberg, Johan; Wemmelund, Kristian Borup; Ravn, Hanne Berg

    2015-07-01

    Right ventricular (RV) failure due to chronic pressure overload is a main determinant of outcome in congenital heart disease. Medical management is challenging because not only contractility but also the interventricular relationship is important for increasing cardiac output. This study evaluated the effect of milrinone alone and in combination with epinephrine or dopamine on hemodynamics, ventricular performance, and the interventricular relationship. RV failure was induced in 21 Danish landrace pigs by pulmonary artery banding. After 10 wk, animals were reexamined using biventricular pressure-volume conductance catheters. The maximum pressure in the RV increased by 113% (P < 0.0001) and end-diastolic volume by 43% (P < 0.002), while left ventricular (LV) pressure simultaneously decreased (P = 0.006). Concomitantly, mean arterial pressure (MAP; -16%, P = 0.01), cardiac index (CI; -23%, P < 0.0001), and mixed venous oxygen saturation (SvO2 ; -40%, P < 0.0001) decreased. Milrinone increased CI (11%, P = 0.008) and heart rate (HR; 21%, P < 0.0001). Stroke volume index (SVI) decreased (7%, P = 0.03), although RV contractility was improved. The addition of either epinephrine or dopamine further increased CI and HR in a dose-dependent manner but without any significant differences between the two interventions. A more pronounced increase in biventricular contractility was observed in the dopamine-treated animals. LV volume was reduced in both the dopamine and epinephrine groups with increasing doses In the failing pressure overloaded RV, milrinone improved CI and increased contractility. Albeit additional dose-dependent effects of both epinephrine and dopamine on CI and contractility, neither of the interventions improved SVI due to reduced filling of the LV. Copyright © 2015 the American Physiological Society.

  7. Atrial isomerism: a surgical experience.

    PubMed

    Sinzobahamvya, N; Arenz, C; Brecher, A M; Urban, A E

    1999-06-01

    Most publications on atrial isomerism are autopsy or case reports. The authors review 41 consecutive children operated on from 1980 through to 1996 with emphasis on associated cardiac anomalies, surgical procedures and outcome. Left atrial isomerism was present in 23 patients. Interruption of the inferior vena cava (56%), atrio-ventricular septal defect (47%), common atrium (38%) and cor triatriatum sinistrum (30%) were the most common diagnoses. Biventricular repair was achieved in 17 children and total cavo-pulmonary connection in two. Three underwent staged palliation: modified Blalock-Taussig shunt for two and bidirectional Glenn anastomosis for one. The remainder received a cardiac pacemaker. One patient died early after repair. Two underwent reoperation to correct a regurgitant left atrio-ventricular valve: one of these, in another hospital, had peroperative death. Three died later. Actuarial survival rate after repair and total cavo-pulmonary connection that was stabilized after 2 years was 84%. In the 18 children with right atrial isomerism, pulmonary atresia or stenosis predominated (89%) with discordant ventriculo-arterial connection (72%), atrio-ventricular septal defect (72%), 'single' ventricle (55%) and extracardiac total anomalous pulmonary venous drainage (50%). Biventricular repair was achieved in two patients and complete Fontan circulation in eight. The other eight underwent various staged palliative procedures and correction of extracardiac total anomalous pulmonary venous drainage. Five patients died postoperatively: two in our unit after modified Blalock-Taussig shunt and total cavo-pulmonary connection, three in other hospitals after repair (n = 1) and Fontan (n = 2). Five died later. One was lost for review. Survival after repair and Fontan stabilized after 6 months at 49%. In conclusion, the cardiovascular malformations associated with left atrial isomerism can often be successfully corrected. Those accompanying right atrial isomerism usually preclude a biventricular repair, require staged palliation and carry a poor prognosis.

  8. Micro-structurally detailed model of a therapeutic hydrogel injectate in a rat biventricular cardiac geometry for computational simulations

    PubMed Central

    Sirry, Mazin S.; Davies, Neil H.; Kadner, Karen; Dubuis, Laura; Saleh, Muhammad G.; Meintjes, Ernesta M.; Spottiswoode, Bruce S.; Zilla, Peter; Franz, Thomas

    2013-01-01

    Biomaterial injection based therapies have showed cautious success in restoration of cardiac function and prevention of adverse remodelling into heart failure after myocardial infarction (MI). However, the underlying mechanisms are not well understood. Computational studies utilised simplified representations of the therapeutic myocardial injectates. Wistar rats underwent experimental infarction followed by immediate injection of polyethylene glycol hydrogel in the infarct region. Hearts were explanted, cryo-sectioned and the region with the injectate histologically analysed. Histological micrographs were used to reconstruct the dispersed hydrogel injectate. Cardiac magnetic resonance imaging (CMRI) data from a healthy rat were used to obtain an end-diastolic biventricular geometry which was subsequently adjusted and combined with the injectate model. The computational geometry of the injectate exhibited microscopic structural details found the in situ. The combination of injectate and cardiac geometry provides realistic geometries for multiscale computational studies of intra-myocardial injectate therapies for the rat model that has been widely used for MI research. PMID:23682845

  9. Neonatal aortic stenosis.

    PubMed

    Drury, Nigel E; Veldtman, Gruschen R; Benson, Lee N

    2005-09-01

    Neonatal aortic stenosis is a complex and heterogeneous condition, defined as left ventricular outflow tract obstruction at valvular level, presenting and often requiring treatment in the first month of life. Initial presentation may be catastrophic, necessitating hemodynamic, respiratory and metabolic resuscitation. Subsequent management is focused on maintaining systemic blood flow, either via a univentricular Norwood palliation or a biventricular route, in which the effective aortic valve area is increased by balloon dilation or surgical valvotomy. In infants with aortic annular hypoplasia but adequately sized left ventricle, the Ross-Konno procedure is also an attractive option. Outcomes after biventricular management have improved in recent years as a consequence of better patient selection, perioperative management and advances in catheter technology. Exciting new developments are likely to significantly modify the natural history of this disorder, including fetal intervention for the salvage of the hypoplastic left ventricle; 3D echocardiography providing better definition of valve morphology and aiding patient selection for a surgical or catheter-based intervention; and new transcutaneous approaches, such as duel beam echo, to perforate the valve.

  10. Self-paced brain-computer interface control of ambulation in a virtual reality environment.

    PubMed

    Wang, Po T; King, Christine E; Chui, Luis A; Do, An H; Nenadic, Zoran

    2012-10-01

    Spinal cord injury (SCI) often leaves affected individuals unable to ambulate. Electroencephalogram (EEG) based brain-computer interface (BCI) controlled lower extremity prostheses may restore intuitive and able-body-like ambulation after SCI. To test its feasibility, the authors developed and tested a novel EEG-based, data-driven BCI system for intuitive and self-paced control of the ambulation of an avatar within a virtual reality environment (VRE). Eight able-bodied subjects and one with SCI underwent the following 10-min training session: subjects alternated between idling and walking kinaesthetic motor imageries (KMI) while their EEG were recorded and analysed to generate subject-specific decoding models. Subjects then performed a goal-oriented online task, repeated over five sessions, in which they utilized the KMI to control the linear ambulation of an avatar and make ten sequential stops at designated points within the VRE. The average offline training performance across subjects was 77.2 ± 11.0%, ranging from 64.3% (p = 0.001 76) to 94.5% (p = 6.26 × 10(-23)), with chance performance being 50%. The average online performance was 8.5 ± 1.1 (out of 10) successful stops and 303 ± 53 s completion time (perfect = 211 s). All subjects achieved performances significantly different than those of random walk (p < 0.05) in 44 of the 45 online sessions. By using a data-driven machine learning approach to decode users' KMI, this BCI-VRE system enabled intuitive and purposeful self-paced control of ambulation after only 10 minutes training. The ability to achieve such BCI control with minimal training indicates that the implementation of future BCI-lower extremity prosthesis systems may be feasible.

  11. Work-related psychosocial risk factors and mental health problems amongst nurses at a university hospital in Estonia: a cross-sectional study.

    PubMed

    Freimann, Tiina; Merisalu, Eda

    2015-07-01

    Rapid changes in the Estonian health care system have placed extra pressure on the nursing profession, but the potential impacts of psychosocial changes have not been investigated. We aimed to explore the work-related psychosocial risk factors and their relationships with mental health problems (MHPs) amongst nurses at the university hospital in Estonia. A cross-sectional survey was undertaken amongst registered nurses at Tartu University Hospital (TUH). Psychosocial work factors and MHPs (stress, somatic symptoms, depressive symptoms and burnout) were measured using version two of the Copenhagen Psychosocial Questionnaire (COPSOQ II). Descriptive statistics and Pearson's r correlation with sequential Bonferroni correction were used to analyse the data. The analysis was based on 404 nurses (45% of the full-time working population of nurses). The highest mean scores recorded for the positive work-related psychosocial factors studied were meaning of work, role clarity, social relationships and mutual trust between employees. The highest scores for the negative factors studied were the demands for hiding emotions, work pace, cognitive and emotional demands. Stress and burnout showed the highest mean scores amongst the MHPs. Quantitative and emotional demands were positively related to all of the studied MHPs, while work pace and role conflicts had a positive correlation with stress and burnout. All of the studied negative psychosocial factors were significantly correlated with burnout. work-related psychosocial risk factors such as quantitative demands work load, emotional demands, work pace and role conflicts, had significant positive relationships with MHPS in nurses in Estonia, and may contribute to high levels of stress as well as burnout amongst nurses: . © 2015 the Nordic Societies of Public Health.

  12. Validation of a defibrillation lead ventricular volume measurement compared to three-dimensional echocardiography.

    PubMed

    Haines, David E; Wong, Wilson; Canby, Robert; Jewell, Coty; Houmsse, Mahmoud; Pederson, David; Sugeng, Lissa; Porterfield, John; Kottam, Anil; Pearce, John; Valvano, Jon; Michalek, Joel; Trevino, Aron; Sagar, Sandeep; Feldman, Marc D

    2017-10-01

    There is increasing evidence that using frequent invasive measures of pressure in patients with heart failure results in improved outcomes compared to traditional measures. Admittance, a measure of volume derived from preexisting defibrillation leads, is proposed as a new technique to monitor cardiac hemodynamics in patients with an implantable defibrillator. The purpose of this study was to evaluate the accuracy of a new ventricular volume sensor (VVS, CardioVol) compared with 3-dimenssional echocardiography (echo) in patients with an implantable defibrillator. Twenty-two patients referred for generator replacement had their defibrillation lead attached to VVS to determine the level of agreement to a volume measurement standard (echo). Two opposite hemodynamic challenges were sequentially applied to the heart (overdrive pacing and dobutamine administration) to determine whether real changes in hemodynamics could be reliably and repeatedly assessed with VVS. Equivalence of end-diastolic volume (EDV) and stroke volume (SV) determined by both methods was also assessed. EDV and SV were compared using VVS and echo. VVS tracked expected physiologic trends. EDV was modulated -10% by overdrive pacing (14 mL). SV was modulated -13.7% during overdrive pacing (-6 mL) and increased over baseline +14.6% (+8 mL) with dobutamine. VVS and echo mean EDVs were found statistically equivalent, with margin of equivalence 13.8 mL (P <.05). Likewise, mean SVs were found statistically equivalent with margin of equivalence 15.8 mL (P <.05). VVS provides an accurate method for ventricular volume assessment using chronically implanted defibrillator leads and is statistically equivalent to echo determination of mean EDV and SV. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Topology and Dynamics of the Zebrafish Segmentation Clock Core Circuit

    PubMed Central

    Schröter, Christian; Isakova, Alina; Hens, Korneel; Soroldoni, Daniele; Gajewski, Martin; Jülicher, Frank; Maerkl, Sebastian J.; Deplancke, Bart; Oates, Andrew C.

    2012-01-01

    During vertebrate embryogenesis, the rhythmic and sequential segmentation of the body axis is regulated by an oscillating genetic network termed the segmentation clock. We describe a new dynamic model for the core pace-making circuit of the zebrafish segmentation clock based on a systematic biochemical investigation of the network's topology and precise measurements of somitogenesis dynamics in novel genetic mutants. We show that the core pace-making circuit consists of two distinct negative feedback loops, one with Her1 homodimers and the other with Her7:Hes6 heterodimers, operating in parallel. To explain the observed single and double mutant phenotypes of her1, her7, and hes6 mutant embryos in our dynamic model, we postulate that the availability and effective stability of the dimers with DNA binding activity is controlled in a “dimer cloud” that contains all possible dimeric combinations between the three factors. This feature of our model predicts that Hes6 protein levels should oscillate despite constant hes6 mRNA production, which we confirm experimentally using novel Hes6 antibodies. The control of the circuit's dynamics by a population of dimers with and without DNA binding activity is a new principle for the segmentation clock and may be relevant to other biological clocks and transcriptional regulatory networks. PMID:22911291

  14. Testosterone, territorial response, and song in seasonally breeding tropical and temperate stonechats.

    PubMed

    Apfelbeck, Beate; Mortega, Kim G; Flinks, Heiner; Illera, Juan Carlos; Helm, Barbara

    2017-04-17

    Testosterone facilitates physiological, morphological, and behavioral changes required for breeding in male vertebrates. However, testosterone concentrations and the link between its seasonal changes and those in reproductive behaviors vary greatly among species. To better understand the impact of tropical and temperate environments and life history factors on this variation, we have compared testosterone, territorial behavior and song performance across sequential stages of the breeding season in males of 16 closely related taxa of East African tropical and West European temperate stonechats (Saxicola spp), which all breed during a short breeding season, but differ in migratory behavior, seasonal territory-acquisition and pace of life. We found that generally, the profiles of testosterone and territorial behavior were similar across latitudes. African stonechats with a slow pace of life had equally high peak testosterone concentrations and responded as aggressively to an intruder as European stonechats with a fast pace of life. However, song performance at the beginning of the breeding season was lower in African than in European stonechats. The differences in song performance were not associated with variation in testosterone levels between tropical and temperate stonechats. The results suggest a very similar role for testosterone as a mediator of high intensity territorial aggression during the fertile period of females in tropical and temperate stonechats, which all are highly seasonal, locally synchronous breeders. A potential explanation may be high risk of extra-pair copulations which has been associated with synchronous breeding. Interestingly, an association was not consistent for song performance. Our data suggest that song performance can be disassociated from peak testosterone levels depending on its role in breeding behavior. Despite similar testosterone levels, European males, which early in the breeding season acquire territories and mates, showed greater song performance than African stonechats, which maintain year-round territories and pair-bonds. Taken together, our study comparing related taxa of old world songbirds suggests that short breeding seasons may be a major selective force for high peak testosterone levels during breeding regardless of latitude and pace of life, but that particular behaviors, in our case song, can be uncoupled from peak testosterone levels.

  15. [Aspergillus fumigatus endocarditis in a patient with a biventricular pacemaker].

    PubMed

    Cuesta, José M; Fariñas, María C; Rodilla, Irene G; Salesa, Ricardo; de Berrazueta, José R

    2005-05-01

    Aspergillus fumigatus endocarditis is one of the rarest and severest complications in cardiological patients. We describe a patient with an intracardial pacemaker who was diagnosed as having Aspergillus fumigatus endocarditis. Postmortem examination showed a large, Aspergillus-infected thrombus encased in the right ventricle, pulmonary trunk and main pulmonary branches.

  16. Impact of Tricuspid Regurgitation on the Success of Atrioventricular Node Ablation for Rate Control in Patients With Atrial Fibrillation: The Node Blast Study.

    PubMed

    Reddy, Yeruva Madhu; Gunda, Sampath; Vallakati, Ajay; Kanmanthareddy, Arun; Pillarisetti, Jayasree; Atkins, Donita; Bommana, Sudharani; Emert, Martin P; Pimentel, Rhea; Dendi, Raghuveer; Berenbom, Loren D; Lakkireddy, Dhanunjaya

    2015-09-15

    Atrioventricular node (AVN) ablation is an effective treatment for symptomatic patients with atrial arrhythmias who are refractory to rhythm and rate control strategies where optimal ventricular rate control is desired. There are limited data on the predictors of failure of AVN ablation. Our objective was to identify the predictors of failure of AVN ablation. This is an observational single-center study of consecutive patients who underwent AVN ablation in a large academic center. Baseline characteristics, procedural variables, and outcomes of AVN ablation were collected. AVN "ablation failure" was defined as resumption of AVN conduction resulting in recurrence of either rapid ventricular response or suboptimal biventricular pacing. A total of 247 patients drug refractory AF who underwent AVN ablation at our center with a mean age of 71 ± 12 years with 46% being males were included. Ablation failure was seen in 11 (4.5%) patients. There were no statistical differences between patients with "ablation failure" versus "ablation success" in any of the baseline clinical variables. Patients with moderate-to-severe tricuspid regurgitation (TR) were much more likely to have ablation failure than those with ablation success (8 [73%] vs 65 [27%]; p = 0.003). All 11 patients with ablation failure had a successful redo procedure, 9 with right and 2 with the left sided approach. On multivariate analysis, presence of moderate-to-severe TR was found to be the only predictor of failure of AVN ablation (odds ratio 9.1, confidence interval 1.99 to 42.22, p = 0.004). In conclusion, moderate-to-severe TR is a strong and independent predictor of failure of AVN ablation. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. MitraClip in CRT non-responders with severe mitral regurgitation.

    PubMed

    Seifert, Martin; Schau, Thomas; Schoepp, Maren; Arya, Anita; Neuss, Michael; Butter, Christian

    2014-11-15

    Severe mitral regurgitation (MR) ≥ 3+ and left ventricular dyssynchrony in heart failure patients are markers of CRT non response. The MitraClip (MC) implantation is a therapy for MR ≥ 3+ in patients with high surgical risk of mitral valve reconstruction. We investigated 42 patients with CRT and MR ≥ 3+ who received an MC device at our center. One and two year mortality rates were compared with the predicted mortality by Seattle Heart Failure Model (SHFM) and meta-analysis global group in chronic heart failure (MAGGIC), using the baseline characteristics of patients at the time of MC implantation. The median time interval between CRT and MC implantation was 20.1 (4.5-43.3) months. In 19 patients we observed a functional regurgitation with normal leaflets and in 23 patients a degenerative mechanism for mitral regurgitation. There was no change in mean QRS duration by biventricular pacing or MC implantation. The use of MC led to significant reductions in: median N-terminal pro-brain natriuretic peptide (NT-proBNP) level (pg/ml) from 3923 to 2636 (p = 0.02), tricuspid regurgitation pressure gradient (TRPG) from 43 to 35 mmHg (p = 0.019) and in left ventricular end-diastolic volume (LVEDV) by MC (p = 0.008). At the 2 year follow-up interval the all-cause mortality was 25%. MC implantation leads to an improvement of NT-proBNP level, TRPG and LVEDV in both functional and degenerative MR but does not influence QRS duration. Two year all-cause mortality was 25% and did not differ significantly from that predicted by SHFM and MAGGIC. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Modifying Ventricular Fibrillation by Targeted Rotor Substrate Ablation: Proof-of-Concept from Experimental Studies to Clinical VF

    PubMed Central

    KRUMMEN, DAVID E.; HAYASE, JUSTIN; VAMPOLA, STEPHEN P.; HO, GORDON; SCHRICKER, AMIR A.; LALANI, GAUTAM G.; BAYKANER, TINA; COE, TAYLOR M.; CLOPTON, PAUL; RAPPEL, WOUTER-JAN; OMENS, JEFFREY H.; NARAYAN, SANJIV M.

    2016-01-01

    Introduction Recent work has suggested a role for organized sources in sustaining ventricular fibrillation (VF). We assessed whether ablation of rotor substrate could modulate VF inducibility in canines, and used this proof-of-concept as a foundation to suppress antiarrhythmic drug-refractory clinical VF in a patient with structural heart disease. Methods and Results In 9 dogs, we introduced 64-electrode basket catheters into one or both ventricles, used rapid pacing at a recorded induction threshold to initiate VF, and then defibrillated after 18±8 seconds. Endocardial rotor sites were identified from basket recordings using phase mapping, and ablation was performed at nonrotor (sham) locations (7 ± 2 minutes) and then at rotor sites (8 ± 2 minutes, P = 0.10 vs. sham); the induction threshold was remeasured after each. Sham ablation did not alter canine VF induction threshold (preablation 150 ± 16 milliseconds, postablation 144 ± 16 milliseconds, P = 0.54). However, rotor site ablation rendered VF noninducible in 6/9 animals (P = 0.041), and increased VF induction threshold in the remaining 3. Clinical proof-of-concept was performed in a patient with repetitive ICD shocks due to VF refractory to antiarrhythmic drugs. Following biventricular basket insertion, VF was induced and then defibrillated. Mapping identified 4 rotors localized at borderzone tissue, and rotor site ablation (6.3 ± 1.5 minutes/site) rendered VF noninducible. The VF burden fell from 7 ICD shocks in 8 months preablation to zero ICD therapies at 1 year, without antiarrhythmic medications. Conclusions Targeted rotor substrate ablation suppressed VF in an experimental model and a patient with refractory VF. Further studies are warranted on the efficacy of VF source modulation. PMID:26179310

  19. Atrial fibrillation in cardiac resynchronization therapy with a defibrillator: a risk factor for mortality, appropriate and inappropriate shocks.

    PubMed

    van Boven, Nick; Theuns, Dominic; Bogaard, Kjell; Ruiter, Jaap; Kimman, Geert; Berman, Lily; VAN DER Ploeg, Tjeerd; Kardys, Isabella; Umans, Victor

    2013-10-01

    Knowledge about predictive factors for mortality and (in)appropriate shocks in cardiac resynchronization therapy with a defibrillator (CRT-D) should be available and updated to predict clinical outcome. We retrospectively analyzed 543 consecutive patients assigned to CRT-D in 2 tertiary medical centers. The aim of this study was to assess risk factors for all-cause mortality, appropriate and inappropriate shocks. Mean follow-up time was 3.2 (±1.8) years. A total of 110 (20%) patients died, 71 (13%) received ≥1 appropriate shocks, and 33 (6.1%) received ≥1 inappropriate shocks. No patients received a His bundle ablation and biventricular pacing percentage was not analyzed. Multivariable Cox regression analysis showed that a history of atrial fibrillation (AF) (HR 1.74 CI 1.06-2.86), higher creatinine (HR 1.12; CI 1.08-1.16), and a poorer left ventricular ejection fraction (LVEF) (HR 0.97; CI 0.94-1.01) independently predict all-cause mortality. In the entire cohort, history of AF and secondary prevention were independent predictors of appropriate shocks and variables associated with inappropriate shocks were history of AF and QRS ≥150 milliseconds. In primary prevention patients, history of AF also predicted appropriate shocks as did ischemic cardiomyopathy and poorer LVEF. History of AF, QRS ≥150 milliseconds, and lower creatinine were associated with inappropriate shocks in this subgroup. Appropriate shocks increased mortality risk, but inappropriate shocks did not. In symptomatic CHF patients treated with CRT-D, history of AF is an independent risk factor not only for mortality, but also for appropriate and inappropriate shocks. Further efforts in AF management may optimize the care in CRT-D patients. © 2013 Wiley Periodicals, Inc.

  20. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    PubMed

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  1. Clinical trials update: IMPROVEMENT-HF, COPERNICUS, MUSTIC, ASPECT-II, APRICOT and HEART.

    PubMed

    Witte, K; Thackray, S; Clark, A L; Cooklin, M; Cleland, J G

    2000-12-01

    Important new studies relevant to the field of heart failure reported at the annual congress of the European Society of Cardiology (ESC), held in Amsterdam in August 2000, are reviewed. The IMPROVEMENT of Heart Failure survey investigated the knowledge and perceptions of over 1300 primary care physicians from 14 ESC member nations and the actual practice in over 11000 of their patients. Guidelines and clinical practice were compared. The survey suggested, in this large sample, that the quality of care was higher than previous smaller surveys have suggested but have also identified important deficiencies in knowledge and management that should be rectified. The COPERNICUS study demonstrated that carvedilol was remarkably well tolerated even in patients with very severe heart failure and that treatment was associated with a substantial reduction in mortality even among patients that would conventionally not be considered, by many, for beta-blocker therapy. The MUSTIC trial suggested that cardiac resynchronisation using biventricular pacing improved patients symptomatically whether or not the patient was in atrial fibrillation. Morbidity and mortality studies of cardiac resynchronisation are now underway. The ASPECT-II and APRICOT-II studies investigated the role of warfarin, aspirin and their combination for the long-term management of myocardial infarction. One interpretation of the data from these studies is that the combination of aspirin and warfarin is about as effective as warfarin alone but with a much higher incidence of side effects. Warfarin alone appeared superior to aspirin alone. In summary, the annual congress of the ESC provided important new information for clinical practice and, to date, was, by far, the most important cardiology congress in the world this year.

  2. The influence of right ventricular stimulation on acute response to cardiac resynchronisation therapy.

    PubMed

    Wu, L; de Roest, G J; Hendriks, M L; van Rossum, A C; de Cock, C C; Allaart, C P

    2016-01-01

    The contribution of right ventricular (RV) stimulation to cardiac resynchronisation therapy (CRT) remains controversial. RV stimulation might be associated with adverse haemodynamic effects, dependent on intrinsic right bundle branch conduction, presence of scar, RV function and other factors which may partly explain non-response to CRT. This study investigates to what degree RV stimulation modulates response to biventricular (BiV) stimulation in CRT candidates and which baseline factors, assessed by cardiac magnetic resonance imaging, determine this modulation. Forty-one patients (24 (59 %) males, 67 ± 10 years, QRS 153 ± 22 ms, 21 (51 %) ischaemic cardiomyopathy, left ventricular (LV) ejection fraction 25 ± 7 %), who successfully underwent temporary stimulation with pacing leads in the RV apex (RVapex) and left ventricular posterolateral (PL) wall were included. Stroke work, assessed by a conductance catheter, was used to assess acute haemodynamic response during baseline conditions and RVapex, PL (LV) and PL+RVapex (BiV) stimulation. Compared with baseline, stroke work improved similarly during LV and BiV stimulation (∆+ 51 ± 42 % and ∆+ 48 ± 47 %, both p < 0.001), but individual response showed substantial differences between LV and BiV stimulation. Multivariate analysis revealed that RV ejection fraction (β = 1.01, p = 0.02) was an independent predictor for stroke work response during LV stimulation, but not for BiV stimulation. Other parameters, including atrioventricular delay and scar presence and localisation, did not predict stroke work response in CRT. The haemodynamic effect of addition of RVapex stimulation to LV stimulation differs widely among patients receiving CRT. Poor RV function is associated with poor response to LV but not BiV stimulation.

  3. Airway Complications of Total Artificial Heart.

    PubMed

    Pathak, Vikas; Donovan, Colin; Malhotra, Rajiv

    2017-02-01

    The total artificial heart is the mechanical device which is used as a bridge to the heart transplant in patients with biventricular failure. Due to the mechanical nature of the device, patients receiving total artificial heart (TAH) require to be on anticoagulation therapy. Hemorrhage and coagulopathy are few of the known complications of TAH.

  4. Total Artificial Heart as Bridge to Heart Transplantation in Chagas Cardiomyopathy: Case Report.

    PubMed

    Ruzza, A; Czer, L S C; De Robertis, M; Luthringer, D; Moriguchi, J; Kobashigawa, J; Trento, A; Arabia, F

    2016-01-01

    Chagas disease (CD) is becoming an increasingly recognized cause of dilated cardiomyopathy outside of Latin America, where it is endemic, due to population shifts and migration. Heart transplantation (HTx) is a therapeutic option for end-stage cardiomyopathy due to CD, but may be considered a relative contraindication due to potential reactivation of the causative organism with immunosuppression therapy. The total artificial heart (TAH) can provide mechanical circulatory support in decompensated patients with severe biventricular dysfunction until the time of HTx, while avoiding immunosuppressive therapy and removing the organ most affected by the causative organism. We report herein a patient with CD and severe biventricular dysfunction, who had mechanical circulatory support with a TAH for more than 6 months, followed by successful orthotopic HTx and treatment with benznidazole for 3 months. The patient had no evidence of recurrent disease in the transplanted heart based on endomyocardial biopsy up to 1 year post-transplantation, and remains alive more than 30 months after insertion of a TAH and 24 months after HTx. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Heterotaxy syndrome: impact of ventricular morphology on resource utilization.

    PubMed

    Amula, Venugopal; Ellsworth, German L; Bratton, Susan L; Arrington, Cammon B; Witte, Madolin K

    2014-01-01

    Patients with heterotaxy syndrome (HS) have significant cardiac and extracardiac anomalies that impact outcome. To improve the management of this complex patient population, we performed a comprehensive analysis of their anatomic and clinical features along with an evaluation of resource utilization data. The objectives were to describe anatomic and clinical features of patients with HS syndrome treated at a single center from 1992 to 2011 focusing on the impact of ventricular morphology (univentricular [UV] vs. biventricular [BV]) on clinical outcomes and resource utilization. Clinical and echocardiographic data from patients with HS were abstracted from medical records. Health care costs were indexed to inflation. Seventy-eight patients were identified with HS ranging in age from 1 day to 29 years old. UV morphology was present in 46 patients (59 %), most commonly with right-ventricular dominance (36 of 46). The presence of extra cardiac anomalies did not differ between the UV and BV groups (82 vs. 78 %) nor did morbidities, such as need for enteral tube feedings (47 vs. 25 %) or pacemaker placement (24 vs. 25 %). Mortality was 28 % in the entire cohort: 39 % in univentricuar patients versus 10.5 % in those with biventricular anatomy. Hospital length of stay for medical illnesses was similar in both groups, but length of stay after surgery was significantly longer in UV than BV patients. Among survivors, UV patients had greater median hospital costs (TeX 67,732, p < 0.001), but when this was adjusted for mortality and variable follow-up, there were no differences in health care costs within the first year of life. Significant health care dollars are used to manage children with HS, the majority of which involve expenses related to surgical care. Although patients with biventricular morphology have better survival, morbidity and resource utilization are similar to those for UV patients especially within the first year of life.

  6. Impaired Right, Left, or Biventricular Function and Resting Oxygen Saturation Are Associated With Mortality in Eisenmenger Syndrome: A Clinical and Cardiovascular Magnetic Resonance Study.

    PubMed

    Jensen, Annette S; Broberg, Craig S; Rydman, Riikka; Diller, Gerhard-Paul; Li, Wei; Dimopoulos, Konstantinos; Wort, Stephen J; Pennell, Dudley J; Gatzoulis, Michael A; Babu-Narayan, Sonya V

    2015-12-01

    Patients with Eisenmenger syndrome (ES) have better survival, despite similar pulmonary vascular pathology, compared with other patients with pulmonary arterial hypertension. Cardiovascular magnetic resonance (CMR) is useful for risk stratification in idiopathic pulmonary arterial hypertension, whereas it has not been evaluated in ES. We studied CMR together with other noninvasive measurements in ES to evaluate its potential role as a noninvasive risk stratification test. Between 2003 and 2005, 48 patients with ES, all with a post-tricuspid shunt, were enrolled in a prospective, longitudinal, single-center study. All patients underwent a standardized baseline assessment with CMR, blood test, echocardiography, and 6-minute walk test and were followed up for mortality until the end of December 2013. Twelve patients (25%) died during follow-up, mostly from heart failure (50%). Impaired ventricular function (right or left ventricular ejection fraction) was associated with increased risk of mortality (lowest quartile: right ventricular ejection fraction, <40%; hazard ratio, 4.4 [95% confidence interval, 1.4-13.5]; P=0.01 and left ventricular ejection fraction, <50%; hazard ratio, 6.6 [95% confidence interval, 2.1-20.8]; P=0.001). Biventricular impairment (lowest quartile left ventricular ejection fraction, <50% and right ventricular ejection fraction, <40%) conveyed an even higher risk of mortality (hazard ratio, 8.0 [95% confidence interval, 2.5-25.1]; P=0.0004). No other CMR or noninvasive measurement besides resting oxygen saturation (hazard ratio, 0.90 [0.83-0.97]/%; P=0.007) was associated with mortality. Impaired right, left, or biventricular systolic function derived from baseline CMR and resting oxygen saturation are associated with mortality in adult patients with ES. CMR is a useful noninvasive tool, which may be incorporated in the risk stratification assessment of ES during lifelong follow-up. © 2015 American Heart Association, Inc.

  7. Bridge to transplantation using paracorporeal biventricular assist devices or the syncardia temporary total artificial heart: is there a difference?

    PubMed

    Nguyen, A; Pozzi, M; Mastroianni, C; Léger, P; Loisance, D; Pavie, A; Leprince, P; Kirsch, M

    2015-06-01

    Biventricular support can be achieved using paracorporeal ventricular assist devices (p-BiVAD) or the Syncardia temporary total artificial heart (t-TAH). The purpose of the present study was to compare survival and morbidity between these devices. Data from 2 French neighboring hospitals were reviewed. Between 1996 and 2009, 148 patients (67 p-BiVADs and 81 t-TAH) underwent primary, planned biventricular support. There were 128 (86%) males aged 44±13 years. Preoperatively, p-BiVAD recipients had significantly lower systolic and diastolic blood pressures, more severe hepatic cytolysis and higher white blood cell counts than t-TAH recipients. In contrast, t-TAH patients had significantly higher rates of pre-implant ECLS and hemofiltration. Mean support duration was 79±100 days for the p-BiVAD group and 71±92 for t-TAH group (P=0.6). Forty two (63%) p-BiVAD recipients were bridged to transplantation (39, 58%) or recovery (3, 5%), whereas 51 (63%) patients underwent transplantation in the t-TAH group. Death on support was similar between groups (p-BiVAD, 26 (39%); t-TAH, 30 (37%); P=0.87). Survival while on device was not significantly different between patient groups and multivariate analysis showed that only preimplant diastolic blood pressure and alanine amino-transferase levels were significant predictors of death. Post-transplant survival in the p-BiVAD group was 76±7%, 70±8%, and 58±9% at 1, 3, and 5 years after transplantation, respectively, and was similar to that of the t-TAH group (77±6%, 72±6%, and 70±7%, P=0.60). Survival while on support and up to 5 years after heart transplantation was not significantly different in patients supported by p-BiVADs or t-TAH. Multivariate analysis revealed that survival while on transplantation was not affected by the type of device implanted.

  8. Accurate means of detecting and characterizing abnormal patterns of ventricular activation by phase image analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Botvinick, E.H.; Frais, M.A.; Shosa, D.W.

    1982-08-01

    The ability of scintigraphic phase image analysis to characterize patterns of abnormal ventricular activation was investigated. The pattern of phase distribution and sequential phase changes over both right and left ventricular regions of interest were evaluated in 16 patients with normal electrical activation and wall motion and compared with those in 8 patients with an artificial pacemaker and 4 patients with sinus rhythm with the Wolff-Parkinson-White syndrome and delta waves. Normally, the site of earliest phase angle was seen at the base of the interventricular septum, with sequential change affecting the body of the septum and the cardiac apex andmore » then spreading laterally to involve the body of both ventricles. The site of earliest phase angle was located at the apex of the right ventricle in seven patients with a right ventricular endocardial pacemaker and on the lateral left ventricular wall in one patient with a left ventricular epicardial pacemaker. In each case the site corresponded exactly to the position of the pacing electrode as seen on posteroanterior and left lateral chest X-ray films, and sequential phase changes spread from the initial focus to affect both ventricles. In each of the patients with the Wolff-Parkinson-White syndrome, the site of earliest ventricular phase angle was located, and it corresponded exactly to the site of the bypass tract as determined by endocardial mapping. In this way, four bypass pathways, two posterior left paraseptal, one left lateral and one right lateral, were correctly localized scintigraphically. On the basis of the sequence of mechanical contraction, phase image analysis provides an accurate noninvasive method of detecting abnormal foci of ventricular activation.« less

  9. Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation.

    PubMed

    Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias

    2016-10-21

    The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].

  10. Biventricular support with the Jarvik 2000 axial flow pump: a feasibility study.

    PubMed

    Radovancevic, Branislav; Gregoric, Igor D; Tamez, Daniel; Vrtovec, Bojan; Tuzun, Egemen; Chee, Hyun Keun; Moore, Sheila; Jarvik, Robert K; Frazier, O H

    2003-01-01

    Patients with congestive heart failure who are supported with a left ventricular assist device (LVAD) may experience right ventricular dysfunction or failure that requires support with a right ventricular assist device (RVAD). To determine the feasibility of using a clinically available axial flow ventricular assist device as an RVAD, we implanted Jarvik 2000 pumps in the left ventricle and right atrium of two Corriente crossbred calves (approximately 100 kg each) by way of a left thoracotomy and then analyzed the hemodynamic effects in the mechanically fibrillated heart at various LVAD and RVAD speeds. Right atrial implantation of the device required no modification of either the device or the surgical technique used for left ventricular implantation. Satisfactory biventricular support was achieved during fibrillation as evidenced by an increase in mean aortic pressure from 34 mm Hg with the pumps off to 78 mm Hg with the pumps generating a flow rate of 4.8 L/min. These results indicate that the Jarvik 2000 pump, which can provide chronic circulatory support and can be powered by external batteries, is a feasible option for right ventricular support after LVAD implantation and is capable of completely supporting the circulation in patients with global heart failure.

  11. Presentation Time Concerning System-Paced Multimedia Instructions and the Superiority of Learner Pacing

    ERIC Educational Resources Information Center

    Stiller, Klaus D.; Petzold, Kirstin; Zinnbauer, Peter

    2011-01-01

    The superiority of learner-paced over system-paced instructions was demonstrated in multiple experiments. In these experiments, the system-paced presentations were highly speeded, causing cognitive overload, while the learner-paced instructions allowed adjustments of the presentational flow to the learner's needs by pacing facilities, mostly…

  12. Cardiovascular Disease in Acromegaly.

    PubMed

    Sharma, Morali D; Nguyen, Anh V; Brown, Spandana; Robbins, Richard J

    2017-01-01

    In patients with acromegaly, chronic excess of growth hormone (GH) and insulin-like growth factor-1 (IGF-1) leads to the development of acromegalic cardiomyopathy. Its main features are biventricular hypertrophy, diastolic dysfunction, and in later stages, systolic dysfunction and congestive heart failure. Surgical and/or pharmacological treatment of acromegaly and control of cardiovascular risk factors help reverse some of these pathophysiologic changes and decrease the high risk of cardiovascular complications.

  13. New Heart Failure Treatment Capability for Remote Environments

    DTIC Science & Technology

    2013-06-01

    valve in a cycle manner. Control of the absolute pressure, rate of actuation and resistance in the 19 drive lines were the manner in which...Hegde SS, Lowe JE. Sensing Lead Insulation Fractures Following Implantable Cardioverter-Defibrillator Placement. ASAIO Journal 1993;39:M711-M714...14:45-46,1985. Anstadt MP, Galbraith TA, Murray KD, Howanitz EP, Myerowitz PD: Bridge to Cardiac Transplantation Using Prosthetic Biventricular

  14. Veno-venous extracorporeal membrane oxygenation using an innovative dual-lumen cannula following implantation of a total artificial heart.

    PubMed

    Youdle, Jemma; Penn, Sarah; Maunz, Olaf; Simon, Andre

    2017-01-01

    We report our first clinical use of the new Protek Duo TM cannula for peripheral veno-venous extra-corporeal life support (ECLS). A 53-year-old male patient underwent implantation of a total artificial heart (TAH) for biventricular failure. However, due to the development of post-operative respiratory dysfunction, the patient required ECLS for six days.

  15. Right-Dominant Unbalanced Atrioventricular Septal Defect: Echocardiography in Surgical Decision Making.

    PubMed

    Arunamata, Alisa; Balasubramanian, Sowmya; Mainwaring, Richard; Maeda, Katsuhide; Selamet Tierney, Elif Seda

    2017-03-01

    Management of right-dominant atrioventricular septal defect (AVSD) remains a challenge given the spectrum of ventricular hypoplasia. The purpose of this study was to assess whether reported echocardiographic indices and additional measurements were associated with operative strategy in right-dominant AVSD. A blinded observer retrospectively reviewed preoperative echocardiograms of patients who underwent surgery for right-dominant AVSD (January 2000 to July 2013). Ventricular dimensions, atrioventricular valve index (AVVI; left valve area/right valve area), and right ventricular (RV)/left ventricular (RV/LV) inflow angle were measured. A second observer measured a subset of studies to assess agreement. Pearson correlation analysis was performed to examine the relationship between ventricular septal defect size (indexed to body surface area) and RV/LV inflow angle in systole. A separate validation cohort was identified using the same methodology (August 2013 to July 2016). Of 46 patients with right-dominant AVSD (median age, 1 day; range, 0-11 months), overall survival was 76% at 7 years. Twenty-eight patients (61%) underwent single-ventricle palliation and had smaller LV dimensions and volumes, AVVIs (P = .005), and RV/LV inflow angles in systole (P = .007) compared with those who underwent biventricular operations. Three patients undergoing biventricular operations underwent transplantation or died and had lower indexed LV end-diastolic volumes compared with the remaining patients (P = .005). Interobserver agreement for the measured echocardiographic indices was good (intraclass correlation coefficient = 0.70-0.95). Ventricular septal defect size and RV/LV inflow angle in systole had a strong negative correlation (r = -0.7, P < .001). In the validation cohort (n = 12), RV/LV inflow angle in systole ≤ 114° yielded sensitivity of 100% and AVVI ≤ 0.70 yielded sensitivity of 88% for single-ventricle palliation. Mortality remains high among patients with right-dominant AVSD. RV/LV inflow angle in systole and AVVI are reproducible measurements that may be used in conjunction with several echocardiographic parameters to support suitability for a biventricular operation in right-dominant AVSD. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  16. Large-Animal Biventricular Working Heart Perfusion System with Low Priming Volume-Comparison between in vivo and ex vivo Cardiac Function.

    PubMed

    Abicht, Jan-Michael; Mayr, Tanja Axinja Jelena; Jauch, Judith; Guethoff, Sonja; Buchholz, Stefan; Reichart, Bruno; Bauer, Andreas

    2018-01-01

    Existing large-animal, ex vivo, cardiac perfusion models are restricted in their ability to establish an ischemia/reperfusion condition as seen in cardiac surgery or transplantation. Other working heart systems only challenge one ventricle or require a substantially larger priming volume. We describe a novel biventricular cardiac perfusion system with reduced priming volume. Juvenile pig hearts were cardiopleged, explanted, and reperfused ex vivo after 150 minutes of cold ischemia. Autologous whole blood was used as perfusate (minimal priming volume 350 mL). After 15 minutes of Langendorff perfusion (LM), the system was switched into a biventricular working mode (WM) and studied for 3 hours. During reperfusion, complete unloading of both ventricles and constant-pressure coronary perfusion was achieved. During working mode perfusion, the preload and afterload pressure of both ventricles was controlled within the targeted physiologic range. Functional parameters such as left ventricular work index were reduced in ex vivo working mode (in vivo: 787 ± 186 vs. 1 h WM 498 ± 66 mm Hg·mL/g·min; p  < 0.01), but remained stable throughout the following study period (3 h WM 517 ± 103 mm Hg·mL/g·min; p  = 0.63). Along with the elevated workload during WM, myocardial metabolism and oxygen consumption increased compared with LM (0.021 ± 0.08 vs. 0.06 ± 0.01 mL/min/g; 1 h after reperfusion). Histologic examination of the myocardium revealed no structural damage. In the ex vivo perfusion system, stable hemodynamic and metabolic conditions can be established for a period of 3 hours while functional and blood parameters are easily accessible. Moreover, because of the minimal priming volume, the novel ex vivo cardiac perfusion circuit allows for autologous perfusion, using the limited amount of blood available from the organ donating animal. Georg Thieme Verlag KG Stuttgart · New York.

  17. Benefit of warm water immersion on biventricular function in patients with chronic heart failure

    PubMed Central

    Grüner Sveälv, Bente; Cider, Åsa; Täng, Margareta Scharin; Angwald, Eva; Kardassis, Dimitris; Andersson, Bert

    2009-01-01

    Background Regular physical activity and exercise are well-known cardiovascular protective factors. Many elderly patients with heart failure find it difficult to exercise on land, and hydrotherapy (training in warm water) could be a more appropriate form of exercise for such patients. However, concerns have been raised about its safety. The aim of this study was to investigate, with echocardiography and Doppler, the acute effect of warm water immersion (WWI) and effect of 8 weeks of hydrotherapy on biventricular function, volumes and systemic vascular resistance. A secondary aim was to observe the effect of hydrotherapy on brain natriuretic peptide (BNP). Methods Eighteen patients [age 69 ± 8 years, left ventricular ejection fraction 31 ± 9%, peakVO2 14.6 ± 4.5 mL/kg/min] were examined with echocardiography on land and in warm water (34°C). Twelve of these patients completed 8 weeks of control period followed by 8 weeks of hydrotherapy twice weekly. Results During acute WWI, cardiac output increased from 3.1 ± 0.8 to 4.2 ± 0.9 L/min, LV tissue velocity time integral from 1.2 ± 0.4 to 1.7 ± 0.5 cm and right ventricular tissue velocity time integral from 1.6 ± 0.6 to 2.5 ± 0.8 cm (land vs WWI, p < 0.0001, respectively). Heart rate decreased from 73 ± 12 to 66 ± 11 bpm (p < 0.0001), mean arterial pressure from 92 ± 14 to 86 ± 16 mmHg (p < 0.01), and systemic vascular resistance from 31 ± 7 to 22 ± 5 resistant units (p < 0.0001). There was no change in the cardiovascular response or BNP after 8 weeks of hydrotherapy. Conclusion Hydrotherapy was well tolerated by all patients. The main observed cardiac effect during acute WWI was a reduction in heart rate, which, together with a decrease in afterload, resulted in increases in systolic and diastolic biventricular function. Although 8 weeks of hydrotherapy did not improve cardiac function, our data support the concept that exercise in warm water is an acceptable regime for patients with heart failure. PMID:19580653

  18. Graves' disease presenting as bi-ventricular heart failure with severe pulmonary hypertension and pre-eclampsia in pregnancy--a case report and review of the literature.

    PubMed

    Sabah, Khandker Mohammad Nurus; Chowdhury, Abdul Wadud; Islam, Mohammad Shahidul; Cader, Fathima Aaysha; Kawser, Shamima; Hosen, Md Imam; Saleh, Mohammed Abaye Deen; Alam, Md Shariful; Chowdhury, Mohammad Monjurul Kader; Tabassum, Humayara

    2014-11-18

    Graves' disease, a well-known cause of hyperthyroidism, is an autoimmune disease with multi-system involvement. More prevalent among young women, it appears as an uncommon cardiovascular complication during pregnancy, posing a diagnostic challenge, largely owing to difficulty in detecting the complication, as a result of a low index of suspicion of Graves' disease presenting during pregnancy. Globally, cardiovascular disease is an important factor for pregnancy-related morbidity and mortality. Here, we report a case of Graves' disease detected for the first time in pregnancy, in a patient presenting with bi- ventricular heart failure, severe pulmonary hypertension and pre- eclampsia. Emphasis is placed on the spectrum of clinical presentations of Graves' disease, and the importance of considering this thyroid disorder as a possible aetiological factor for such a presentation in pregnancy. A 30-year-old Bangladeshi-Bengali woman, in her 28th week of pregnancy presented with severe systemic hypertension, bi-ventricular heart failure and severe pulmonary hypertension with a moderately enlarged thyroid gland. She improved following the administration of high dose intravenous diuretics, and delivered a premature female baby of low birth weight per vaginally, twenty four hours later. Pre-eclampsia was diagnosed on the basis of hypertension first detected in the third trimester, 3+ oedema and mild proteinuria. Electrocardiography revealed sinus tachycardia with incomplete right bundle branch block and echocardiography showed severe pulmonary hypertension with an estimated pulmonary arterial systolic pressure of 73 mm Hg, septal and anterior wall hypokinesia with an ejection fraction of 51%, grade I mitral and tricuspid regurgitation. Thyroid function tests revealed a biochemically hyperthyroid state and positive anti- thyroid peroxidase antibodies was found. (99m)Technetium pertechnetate thyroid scans demonstrated diffuse toxic goiter as evidenced by an enlarged thyroid gland with intense radiotracer concentration all over the gland. The clinical and biochemical findings confirmed the diagnosis of Graves' disease. Graves' disease is an uncommon cause of bi-ventricular heart failure and severe pulmonary hypertension in pregnancy, and a high index of clinical suspicion is paramount to its effective diagnosis and treatment.

  19. Gestures in an Intelligent User Interface

    NASA Astrophysics Data System (ADS)

    Fikkert, Wim; van der Vet, Paul; Nijholt, Anton

    In this chapter we investigated which hand gestures are intuitive to control a large display multimedia interface from a user's perspective. Over the course of two sequential user evaluations, we defined a simple gesture set that allows users to fully control a large display multimedia interface, intuitively. First, we evaluated numerous gesture possibilities for a set of commands that can be issued to the interface. These gestures were selected from literature, science fiction movies, and a previous exploratory study. Second, we implemented a working prototype with which the users could interact with both hands and the preferred hand gestures with 2D and 3D visualizations of biochemical structures. We found that the gestures are influenced to significant extent by the fast paced developments in multimedia interfaces such as the Apple iPhone and the Nintendo Wii and to no lesser degree by decades of experience with the more traditional WIMP-based interfaces.

  20. The Effects of Similarity on High-Level Visual Working Memory Processing.

    PubMed

    Yang, Li; Mo, Lei

    2017-01-01

    Similarity has been observed to have opposite effects on visual working memory (VWM) for complex images. How can these discrepant results be reconciled? To answer this question, we used a change-detection paradigm to test visual working memory performance for multiple real-world objects. We found that working memory for moderate similarity items was worse than that for either high or low similarity items. This pattern was unaffected by manipulations of stimulus type (faces vs. scenes), encoding duration (limited vs. self-paced), and presentation format (simultaneous vs. sequential). We also found that the similarity effects differed in strength in different categories (scenes vs. faces). These results suggest that complex real-world objects are represented using a centre-surround inhibition organization . These results support the category-specific cortical resource theory and further suggest that centre-surround inhibition organization may differ by category.

  1. Temporary atrial epicardial pacing as prophylaxis against atrial fibrillation after heart surgery: a meta-analysis.

    PubMed

    Daoud, Emile G; Snow, Rick; Hummel, John D; Kalbfleisch, Steven J; Weiss, Raul; Augostini, Ralph

    2003-02-01

    Recent studies have reported the use of temporary epicardial atrial pacing as prophylaxis for postoperative atrial fibrillation (AF). The aim of this study was to assess the effect of pacing therapies for prevention of postoperative AF using meta-analysis. Using a computerized MEDLINE search, eight pacing prophylaxis trials with 776 patients were included in the meta-analysis. Trials compared control patients to patients randomized to right atrial, left atrial, or biatrial pacing used in conjunction with either fixed high-rate pacing or overdrive pacing. Overdrive biatrial pacing (OR 2.6, CI 1.4-4.8), overdrive right atrial pacing (OR 1.8, CI 1.1-2.7), and fixed high-rate biatrial pacing (OR 2.5, CI 1.3-5.1) demonstrated a significant antiarrhythmic effect for prevention of AF after open heart surgery. Furthermore, studies investigating overdrive left atrial pacing and fixed high-rate right atrial pacing have been underpowered to assess efficacy. Biatrial overdrive and fixed high-rate pacing and right atrial fixed high-rate pacing reduced the risk of new-onset AF after open heart surgery, and the relative risk reduction is approximately 2.5-fold. These results imply that various pacing algorithms are useful as a nonpharmacologic method to prevent postoperative AF.

  2. 42 CFR 460.60 - PACE organizational structure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false PACE organizational structure. 460.60 Section 460.60 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... ELDERLY (PACE) PACE Administrative Requirements § 460.60 PACE organizational structure. (a) A PACE...

  3. 42 CFR 460.6 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Basis... enrolled in a PACE program. PACE stands for programs of all-inclusive care for the elderly. PACE center is... care for the elderly that is operated by an approved PACE organization and that provides comprehensive...

  4. 42 CFR 460.6 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Basis... enrolled in a PACE program. PACE stands for programs of all-inclusive care for the elderly. PACE center is... care for the elderly that is operated by an approved PACE organization and that provides comprehensive...

  5. 42 CFR 460.180 - Medicare payment to PACE organizations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Medicare payment to PACE organizations. 460.180... FOR THE ELDERLY (PACE) Payment § 460.180 Medicare payment to PACE organizations. (a) Principle of payment. Under a PACE program agreement, CMS makes a prospective monthly payment to the PACE organization...

  6. Flail anterior tricuspid valve leaflet in a neonate: association with maternal antiphospholipid syndrome.

    PubMed

    Tarca, Adrian J; Eckersley, Luke; Kothari, Darshan

    2017-10-01

    This brief report describes a case of flail anterior tricuspid valve leaflet in a neonate associated with maternal antiphospholipid syndrome. Fetal echocardiography at 27 weeks of gestation showed competent atrioventricular valves with biventricular echogenic chordae. Fetal distress was noted at delivery, and echocardiography showed a flail anterior leaflet of the tricuspid valve with severe regurgitation. Possible causation and implications of maternal antiphospholipid syndrome are discussed.

  7. Arrhythmogenic ventricular cardiomyopathy: A paradigm shift from right to biventricular disease

    PubMed Central

    Saguner, Ardan M; Brunckhorst, Corinna; Duru, Firat

    2014-01-01

    Arrhythmogenic ventricular cardiomyopathy (AVC) is generally referred to as arrhythmogenic right ventricular (RV) cardiomyopathy/dysplasia and constitutes an inherited cardiomyopathy. Affected patients may succumb to sudden cardiac death (SCD), ventricular tachyarrhythmias (VTA) and heart failure. Genetic studies have identified causative mutations in genes encoding proteins of the intercalated disk that lead to reduced myocardial electro-mechanical stability. The term arrhythmogenic RV cardiomyopathy is somewhat misleading as biventricular involvement or isolated left ventricular (LV) involvement may be present and thus a broader term such as AVC should be preferred. The diagnosis is established on a point score basis according to the revised 2010 task force criteria utilizing imaging modalities, demonstrating fibrous replacement through biopsy, electrocardiographic abnormalities, ventricular arrhythmias and a positive family history including identification of genetic mutations. Although several risk factors for SCD such as previous cardiac arrest, syncope, documented VTA, severe RV/LV dysfunction and young age at manifestation have been identified, risk stratification still needs improvement, especially in asymptomatic family members. Particularly, the role of genetic testing and environmental factors has to be further elucidated. Therapeutic interventions include restriction from physical exercise, beta-blockers, sotalol, amiodarone, implantable cardioverter-defibrillators and catheter ablation. Life-long follow-up is warranted in symptomatic patients, but also asymptomatic carriers of pathogenic mutations. PMID:24772256

  8. Long-term Results After Open Mitral Commissurotomy for a One-Month-Old Infant With Mitral Stenosis.

    PubMed

    Kitaichi, Takashi; Sugano, Mikio; Arase, Hiroki; Kawatani, Yohei; Kameta, Kanako; Kurobe, Hirotsugu; Fujimoto, Eiki; Ono, Akemi; Hayabuchi, Yasunobu; Fujita, Hiroshi; Sogabe, Hitoshi; Kitagawa, Tetsuya

    2017-01-01

    The strategy for an infant with congenital mitral stenosis should be determined by three important factors: left ventricular volume, the degree of the systemic outflow tract obstruction, and the type of mitral valve dysfunction. A successful staged biventricular repair in early infancy for a patient who had congenital mitral stenosis with short chordae, hypoplastic left ventricle and coarctation of the aorta, and the long-term results are described. There were the following important hemodynamic factors that led to the successful biventricular repair in the patient. Total systemic output was barely supplied through the hypoplastic left ventricle after closure of the ductus arteriosus on admission. The neonate underwent repair of coarctation of the aorta alone as the initial stage at 9 days after birth. Also, spontaneous closure of the foramen ovale following repair of coarctation of the aorta accelerated the progressive left ventricular growth. Open mitral commissurotomy with an interatrial fenestration using the modified Brawley's approach was performed for a 40-day-old infant. Good left ventricular growth and good mitral valve function have been observed for 18 years after open mitral commissurotomy. Appropriate early augmentation of left ventricular inflow through the mitral valve might be effective for growth of a hypoplastic left ventricle. J. Med. Invest. 64: 187-191, February, 2017.

  9. 42 CFR 460.34 - Duration of PACE program agreement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Program Agreement § 460.34 Duration of PACE program agreement. An agreement is...

  10. 42 CFR 460.34 - Duration of PACE program agreement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Program Agreement § 460.34 Duration of PACE program agreement. An agreement is...

  11. Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs.

    PubMed

    Shinbane, Jerold S; Colletti, Patrick M; Shellock, Frank G

    2011-10-27

    Advances in cardiac device technology have led to the first generation of magnetic resonance imaging (MRI) conditional devices, providing more diagnostic imaging options for patients with these devices, but also new controversies. Prior studies of pacemakers in patients undergoing MRI procedures have provided groundwork for design improvements. Factors related to magnetic field interactions and transfer of electromagnetic energy led to specific design changes. Ferromagnetic content was minimized. Reed switches were modified. Leads were redesigned to reduce induced currents/heating. Circuitry filters and shielding were implemented to impede or limit the transfer of certain unwanted electromagnetic effects. Prospective multicenter clinical trials to assess the safety and efficacy of the first generation of MR conditional cardiac pacemakers demonstrated no significant alterations in pacing parameters compared to controls. There were no reported complications through the one month visit including no arrhythmias, electrical reset, inhibition of generator output, or adverse sensations. The safe implementation of these new technologies requires an understanding of the well-defined patient and MR system conditions. Although scanning a patient with an MR conditional device following the strictly defined patient and MR system conditions appears straightforward, issues related to patients with pre-existing devices remain complex. Until MR conditional devices are the routine platform for all of these devices, there will still be challenging decisions regarding imaging patients with pre-existing devices where MRI is required to diagnose and manage a potentially life threatening or serious scenario. A range of other devices including ICDs, biventricular devices, and implantable physiologic monitors as well as guidance of medical procedures using MRI technology will require further biomedical device design changes and testing. The development and implementation of cardiac MR conditional devices will continue to require the expertise and collaboration of multiple disciplines and will need to prove safety, effectiveness, and cost effectiveness in patient care.

  12. Does permanent atrial fibrillation modify response to cardiac resynchronization therapy in heart failure patients?

    PubMed

    Abreu, Ana; Oliveira, Mário; Silva Cunha, Pedro; Santa Clara, Helena; Portugal, Guilherme; Gonçalves Rodrigues, Inês; Santos, Vanessa; Morais, Luís; Selas, Mafalda; Soares, Rui; Branco, Luísa; Ferreira, Rui; Mota Carmo, Miguel

    2017-10-01

    The benefits of cardiac resynchronization therapy (CRT) documented in heart failure (HF) may be influenced by atrial fibrillation (AF). We aimed to compare CRT response in patients in AF and in sinus rhythm (SR). We prospectively studied 101 HF patients treated by CRT. Rates of clinical, echocardiographic and functional response, baseline NYHA class and variation, left ventricular ejection fraction, volumes and mass, atrial volumes, cardiopulmonary exercise test (CPET) duration (CPET dur), peak oxygen consumption (VO 2 max) and ventilatory efficiency (VE/VCO 2 slope) were compared between AF and SR patients, before and at three and six months after implantation of a CRT device. All patients achieved ≥95% biventricular pacing, and 5.7% underwent atrioventricular junction ablation. Patients were divided into AF (n=35) and SR (n=66) groups; AF patients were older, with larger atrial volumes and lower CPET dur and VO 2 max before CRT. The percentages of clinical and echocardiographic responders were similar in the two groups, but there were more functional responders in the AF group (71% vs. 39% in SR patients; p=0.012). In SR patients, left atrial volume and left ventricular mass were significantly reduced (p=0.015 and p=0.021, respectively), whereas in AF patients, CPET dur (p=0.003) and VO 2 max (p=0.001; 0.083 age-adjusted) showed larger increases. Clinical and echocardiographic response rates were similar in SR and AF patients, with a better functional response in AF. Improvement in left ventricular function and volumes occurred in both groups, but left ventricular mass reduction and left atrial reverse remodeling were seen exclusively in SR patients (ClinicalTrials.gov identifier: NCT02413151; FCT code: PTDC/DES/120249/2010). Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Effect of study design on the reported effect of cardiac resynchronization therapy (CRT) on quantitative physiological measures: stratified meta-analysis in narrow-QRS heart failure and implications for planning future studies.

    PubMed

    Jabbour, Richard J; Shun-Shin, Matthew J; Finegold, Judith A; Afzal Sohaib, S M; Cook, Christopher; Nijjer, Sukhjinder S; Whinnett, Zachary I; Manisty, Charlotte H; Brugada, Josep; Francis, Darrel P

    2015-01-06

    Biventricular pacing (CRT) shows clear benefits in heart failure with wide QRS, but results in narrow QRS have appeared conflicting. We tested the hypothesis that study design might have influenced findings. We identified all reports of CRT-P/D therapy in subjects with narrow QRS reporting effects on continuous physiological variables. Twelve studies (2074 patients) met these criteria. Studies were stratified by presence of bias-resistance steps: the presence of a randomized control arm over a single arm, and blinded outcome measurement. Change in each endpoint was quantified using a standardized effect size (Cohen's d). We conducted separate meta-analyses for each variable in turn, stratified by trial quality. In non-randomized, non-blinded studies, the majority of variables (10 of 12, 83%) showed significant improvement, ranging from a standardized mean effect size of +1.57 (95%CI +0.43 to +2.7) for ejection fraction to +2.87 (+1.78 to +3.95) for NYHA class. In the randomized, non-blinded study, only 3 out of 6 variables (50%) showed improvement. For the randomized blinded studies, 0 out of 9 variables (0%) showed benefit, ranging from -0.04 (-0.31 to +0.22) for ejection fraction to -0.1 (-0.73 to +0.53) for 6-minute walk test. Differences in degrees of resistance to bias, rather than choice of endpoint, explain the variation between studies of CRT in narrow-QRS heart failure addressing physiological variables. When bias-resistance features are implemented, it becomes clear that these patients do not improve in any tested physiological variable. Guidance from studies without careful planning to resist bias may be far less useful than commonly perceived. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  14. Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs

    PubMed Central

    2011-01-01

    Advances in cardiac device technology have led to the first generation of magnetic resonance imaging (MRI) conditional devices, providing more diagnostic imaging options for patients with these devices, but also new controversies. Prior studies of pacemakers in patients undergoing MRI procedures have provided groundwork for design improvements. Factors related to magnetic field interactions and transfer of electromagnetic energy led to specific design changes. Ferromagnetic content was minimized. Reed switches were modified. Leads were redesigned to reduce induced currents/heating. Circuitry filters and shielding were implemented to impede or limit the transfer of certain unwanted electromagnetic effects. Prospective multicenter clinical trials to assess the safety and efficacy of the first generation of MR conditional cardiac pacemakers demonstrated no significant alterations in pacing parameters compared to controls. There were no reported complications through the one month visit including no arrhythmias, electrical reset, inhibition of generator output, or adverse sensations. The safe implementation of these new technologies requires an understanding of the well-defined patient and MR system conditions. Although scanning a patient with an MR conditional device following the strictly defined patient and MR system conditions appears straightforward, issues related to patients with pre-existing devices remain complex. Until MR conditional devices are the routine platform for all of these devices, there will still be challenging decisions regarding imaging patients with pre-existing devices where MRI is required to diagnose and manage a potentially life threatening or serious scenario. A range of other devices including ICDs, biventricular devices, and implantable physiologic monitors as well as guidance of medical procedures using MRI technology will require further biomedical device design changes and testing. The development and implementation of cardiac MR conditional devices will continue to require the expertise and collaboration of multiple disciplines and will need to prove safety, effectiveness, and cost effectiveness in patient care. PMID:22032338

  15. Bachmann's Bundle Pacing not Only Improves Interatrial Conduction but Also Reduces the Need for Ventricular Pacing.

    PubMed

    Sławuta, Agnieszka; Kliś, Magdalena; Skoczyński, Przemysław; Bańkowski, Tomasz; Moszczyńska-Stulin, Joanna; Gajek, Jacek

    2016-01-01

    Patients treated for sick sinus syndrome may have interatrial conduction disorder leading to atrial fibrillation. This study was aimed to assess the influence of the atrial pacing site on interatrial and atrioventricular conduction as well as the percentage of ventricular pacing in patients with sick sinus syndrome implanted with atrioventricular pacemaker. The study population: 96 patients (58 females, 38 males) aged 74.1 ± 11.8 years were divided in two groups: Group 1 (n = 44) with right atrial appendage pacing and group 2 (n = 52) with Bachmann's area pacing. We assessed the differences in atrioventricular conduction in sinus rhythm and atrial 60 and 90 bpm pacing, P-wave duration and percentage of ventricular pacing. No differences in baseline P-wave duration in sinus rhythm between the groups (102.4 ± 17 ms vs. 104.1 ± 26 ms, p = ns.) were noted. Atrial pacing 60 bpm resulted in longer P-wave in group 1 vs. group 2 (138.3 ± 21 vs. 106.1 ± 15 ms, p < 0.01). The differences between atrioventricular conduction time during sinus rhythm and atrial pacing at 60 and 90 bpm were significantly longer in patients with right atrial appendage vs. Bachmann's pacing (44.1 ± 17 vs. 9.2 ± 7 ms p < 0.01 and 69.2 ± 31 vs. 21.4 ± 12 ms p < 0.05, respectively). The percentage of ventricular pacing was higher in group 1 (21 vs. 4%, p < 0.01). Bachmann's bundle pacing decreases interatrial and atrioventricular conduction delay. Moreover, the frequency-dependent atrioventricular conduction lengthening is much less pronounced during Bachmann's bundle pacing. Right atrial appendage pacing in sick sinus syndrome patients promotes a higher percentage of ventricular pacing.

  16. 42 CFR 460.32 - Content and terms of PACE program agreement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Program Agreement § 460.32 Content and terms of PACE program agreement. (a...

  17. 42 CFR 460.90 - PACE benefits under Medicare and Medicaid.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Services § 460.90 PACE benefits under Medicare and Medicaid. If a Medicare...

  18. Multi-Leu PACE4 Inhibitor Retention within Cells Is PACE4 Dependent and a Prerequisite for Antiproliferative Activity

    PubMed Central

    Ly, Kévin; Levesque, Christine; Kwiatkowska, Anna; Ait-Mohand, Samia; Desjardins, Roxane; Guérin, Brigitte; Day, Robert

    2015-01-01

    The overexpression as well as the critical implication of the proprotein convertase PACE4 in prostate cancer progression has been previously reported and supported the development of peptide inhibitors. The multi-Leu peptide, a PACE4-specific inhibitor, was further generated and its capability to be uptaken by tumor xenograft was demonstrated with regard to its PACE4 expression status. To investigate whether the uptake of this inhibitor was directly dependent of PACE4 levels, uptake and efflux from cancer cells were evaluated and correlations were established with PACE4 contents on both wild type and PACE4-knockdown cell lines. PACE4-knockdown associated growth deficiencies were established on the knockdown HepG2, Huh7, and HT1080 cells as well as the antiproliferative effects of the multi-Leu peptide supporting the growth capabilities of PACE4 in cancer cells. PMID:26114115

  19. Applicability of the iterative technique for cardiac resynchronization therapy optimization: full-disclosure, 50-sequential-patient dataset of transmitral Doppler traces, with implications for future research design and guidelines.

    PubMed

    Jones, Siana; Shun-Shin, Matthew J; Cole, Graham D; Sau, Arunashis; March, Katherine; Williams, Suzanne; Kyriacou, Andreas; Hughes, Alun D; Mayet, Jamil; Frenneaux, Michael; Manisty, Charlotte H; Whinnett, Zachary I; Francis, Darrel P

    2014-04-01

    Full-disclosure study describing Doppler patterns during iterative atrioventricular delay (AVD) optimization of biventricular pacemakers (cardiac resynchronization therapy, CRT). Doppler traces of the first 50 eligible patients undergoing iterative Doppler AVD optimization in the BRAVO trial were examined. Three experienced observers classified conformity to guideline-described patterns. Each observer then selected the optimum AVD on two separate occasions: blinded and unblinded to AVD. Four Doppler E-A patterns occurred: A (always merged, 18% of patients), B (incrementally less fusion at short AVDs, 12%), C (full separation at short AVDs, as described by the guidelines, 28%), and D (always separated, 42%). In Groups A and D (60%), the iterative guidelines therefore cannot specify one single AVD. On the kappa scale (0 = chance alone; 1 = perfect agreement), observer agreement for the ideal AVD in Classes B and C was poor (0.32) and appeared worse in Groups A and D (0.22). Blinding caused the scattering of the AVD selected as optimal to widen (standard deviation rising from 37 to 49 ms, P < 0.001). By blinding 28% of the selected optimum AVDs were ≤60 or ≥200 ms. All 50 Doppler datasets are presented, to support future methodological testing. In most patients, the iterative method does not clearly specify one AVD. In all the patients, agreement on the ideal AVD between skilled observers viewing identical images is poor. The iterative protocol may successfully exclude some extremely unsuitable AVDs, but so might simply accepting factory default. Irreproducibility of the gold standard also prevents alternative physiological optimization methods from being validated honestly.

  20. Current state of total artificial heart therapy and introduction of the most important total artificial heart systems.

    PubMed

    Spiliopoulos, Sotirios; Hergesell, Vera; Wasler, Andrae; Dapunt, Otto

    2018-06-14

    Due to the declining instances of organ donation, total artificial heart (TAH) therapy is of increasing importance for the management of end-stage biventricular heart failure. We introduce the currently most important established and novel TAH systems (SynCardia, CARMAT, ReinHeart, BiVACOR), report clinical outcomes and discuss technical requirements for the successful implementation of TAH therapy as an alternative to cardiac transplantation.

  1. Diaphragm pacing after bilateral implantation of intradiaphragmatic phrenic stimulation electrodes through a transmediastinal endoscopic minimally invasive approach: pilot animal data.

    PubMed

    Assouad, Jalal; Masmoudi, Hicham; Gonzalez-Bermejo, Jesus; Morélot-Panzini, Capucine; Diop, Moustapha; Grunenwald, Dominique; Similowski, Thomas

    2012-08-01

    Phrenic nerve stimulation for diaphragm pacing allows patients with central respiratory paralysis to be weaned from mechanical ventilation. Two procedures are available, either intrathoracic (bilateral thoracotomy) or intradiaphragmatic (four ports laparoscopy). The present experimental work assesses the feasibility, safety and efficacy of a trans-mediastinal implantation of intradiaphragmatic phenic nerve stimulation electrodes using a flexible gastroscope through a cervical incision. We operated on nine ewes. After selective bronchial intubation, we dissected the latero-tracheal space and opened both mediastinal pleura. We then introduced a flexible gastroscope into the pleural cavities, in a sequential manner. The phrenic nerves were located and followed up to the diaphragm dome. Electrodes loaded within a long, pliable needle were introduced through the adjacent intercostal space and implanted in each hemidiaphragm, at a 'tendinous' location (as close as possible to the entry of the nerve in the central tendon), and at a more lateral 'muscular' location. Postoperatively, the animals were ventilated using bilateral phrenic nerve stimulation. After euthanasia, abdominal verification of the electrodes position was performed through a laparotomy. The mediastinal and pleural parts of the procedure were uneventful. The insertion of electrodes was associated with transdiaphragmatic puncture and small abdominal haematomas in the first two animals studied. After a slight modification of the insertion technique, this was not observed anymore. Phrenic nerve stimulation produced efficient ventilation, with tidal volumes significantly higher when delivered at the tendinous site than at the muscular site. The trans-mediastinal implantation of intradiaphragmatic phrenic nerve stimulation electrodes is feasible, appears reasonably safe, and allows efficient ventilation.

  2. Influence of Pacing by Periodic Auditory Stimuli on Movement Continuation: Comparison with Self-regulated Periodic Movement

    PubMed Central

    Ito, Masanori; Kado, Naoki; Suzuki, Toshiaki; Ando, Hiroshi

    2013-01-01

    [Purpose] The purpose of this study was to investigate the influence of external pacing with periodic auditory stimuli on the control of periodic movement. [Subjects and Methods] Eighteen healthy subjects performed self-paced, synchronization-continuation, and syncopation-continuation tapping. Inter-onset intervals were 1,000, 2,000 and 5,000 ms. The variability of inter-tap intervals was compared between the different pacing conditions and between self-paced tapping and each continuation phase. [Results] There were no significant differences in the mean and standard deviation of the inter-tap interval between pacing conditions. For the 1,000 and 5,000 ms tasks, there were significant differences in the mean inter-tap interval following auditory pacing compared with self-pacing. For the 2,000 ms syncopation condition and 5,000 ms task, there were significant differences from self-pacing in the standard deviation of the inter-tap interval following auditory pacing. [Conclusion] These results suggest that the accuracy of periodic movement with intervals of 1,000 and 5,000 ms can be improved by the use of auditory pacing. However, the consistency of periodic movement is mainly dependent on the inherent skill of the individual; thus, improvement of consistency based on pacing is unlikely. PMID:24259932

  3. Functional characteristics of left ventricular synchronization via right ventricular outflow-tract pacing detected by two-dimensional strain echocardiography.

    PubMed

    Hirayama, Yasutaka; Kawamura, Yuichiro; Sato, Nobuyuki; Saito, Tatsuya; Tanaka, Hideichi; Saijo, Yasuaki; Kikuchi, Kenjiro; Ohori, Katsumi; Hasebe, Naoyuki

    2017-02-01

    Recently, due to the detrimental effects on the ventricular function associated with right ventricular apical (RVA) pacing, right ventricular septal (RVS) pacing has become the preferred pacing method. However, the term RVS pacing refers to both right ventricular outflow-tract (RVOT) and mid-septal (RVMS) pacing, leading to a misinterpretation of the results of clinical studies. The purpose of this study, therefore, was to elucidate the functional differences of RVA, RVOT, and RVMS pacing in patients with atrioventricular block. We compared the QRS duration, global longitudinal strain (GLS), and left ventricular (LV) synchronization parameters at the three pacing sites in 47 patients. The peak systolic strain (PSS) time delay between the earliest and latest segments among the 18 LV segments and standard deviation (SD) of the time to the PSS were also calculated for the 18 LV segments at each pacing site using two-dimensional (2D) strain echocardiography. RVMS pacing was associated with a significantly shorter QRS duration compared with RVA and RVOT pacing (154.4±21.4 vs 186.5±19.9 and 171.1±21.5 ms, P <0.001). In contrast, RVOT pacing revealed a greater GLS (-14.69±4.92 vs -13.12±4.76 and -13.51±4.81%, P <0.001), shorter PSS time delay between the earliest and latest segments (236.0±87.9 vs 271.3±102.9 and 281.9±126.6%, P =0.007), and shorter SD of the time to the PSS (70.8±23.8 vs 82.7±30.8 and 81.5±33.7 ms, P =0.002) compared with RVA and RVMS pacing. These results suggest that the functional characteristics of RVOT pacing may be a more optimal pacing site than RVMS, regardless of the pacing QRS duration, in patients with atrioventricular conduction disorders.

  4. Altering Pace Control and Pace Regulation: Attentional Focus Effects during Running.

    PubMed

    Brick, Noel E; Campbell, Mark J; Metcalfe, Richard S; Mair, Jacqueline L; Macintyre, Tadhg E

    2016-05-01

    To date, there are no published studies directly comparing self-controlled (SC) and externally controlled (EC) pace endurance tasks. However, previous research suggests pace control may impact on cognitive strategy use and effort perceptions. The primary aim of this study was to investigate the effects of manipulating perception of pace control on attentional focus, physiological, and psychological outcomes during running. The secondary aim was to determine the reproducibility of self-paced running performance when regulated by effort perceptions. Twenty experienced endurance runners completed four 3-km time trials on a treadmill. Subjects completed two SC pace trials, one perceived exertion clamped (PE) trial, and one EC pace time trial. PE and EC were completed in a counterbalanced order. Pacing strategy for EC and perceived exertion instructions for PE replicated the subjects' fastest SC time trial. Subjects reported a greater focus on cognitive strategies such as relaxing and optimizing running action during EC than during SC. The mean HR was 2% lower during EC than that during SC despite an identical pacing strategy. Perceived exertion did not differ between the three conditions. However, increased internal sensory monitoring coincided with elevated effort perceptions in some subjects during EC and a 10% slower completion time for PE (13.0 ± 1.6 min) than that for SC (11.8 ± 1.2 min). Altering pace control and pace regulation impacted on attentional focus. External control over pacing may facilitate performance, particularly when runners engage attentional strategies conducive to improved running efficiency. However, regulating pace based on effort perceptions alone may result in excessive monitoring of bodily sensations and a slower running speed. Accordingly, attentional focus interventions may prove beneficial for some athletes to adopt task-appropriate attentional strategies to optimize performance.

  5. Accelerated graft dysfunction in heart transplant patients with persistent atrioventricular conduction block.

    PubMed

    Lee, William; Tay, Andre; Walker, Bruce D; Kuchar, Dennis L; Hayward, Christopher S; Spratt, Phillip; Subbiah, Rajesh N

    2016-12-01

    Bradyarrhythmia following heart transplantation is common-∼7.5-24% of patients require permanent pacemaker (PPM) implantation. While overall mortality is similar to their non-paced counterparts, the effects of chronic right ventricular pacing (CRVP) in heart transplant patients have not been studied. We aim to examine the effects of CRVP on heart failure and mortality in heart transplant patients. Records of heart transplant recipients requiring PPM at St Vincent's Hospital, Sydney, Australia between January 1990 and January 2015 were examined. Patient's without a right ventricular (RV) pacing lead or a follow-up time of <1 year were excluded. Patients with pre-existing abnormal left ventricular function (<50%) were analysed separately. Patients were grouped by pacing dependence (100% pacing dependent vs. non-pacing dependent). The primary endpoint was clinical or echocardiographic heart failure (<35%) in the first 5 years post-PPM. Thirty-three of 709 heart transplant recipients were studied. Two patients had complete RV pacing dependence, and the remaining 31 patients had varying degrees of pacing requirement, with an underlying ventricular escape rhythm. The primary endpoint occurred significantly more in the pacing-dependent group; 2 (100%) compared with 2 (6%) of the non pacing dependent group (P < 0.0001 by log-rank analysis, HR = 24.58). Non-pacing-dependent patients had reversible causes for heart failure, unrelated to pacing. In comparison, there was no other cause of heart failure in the pacing-dependent group. Permanent atrioventricular block is rare in the heart transplant population. We have demonstrated CRVP as a potential cause of accelerated graft failure in pacing-dependent heart transplant patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  6. Prospective randomized study to assess the efficacy of site and rate of atrial pacing on long-term progression of atrial fibrillation in sick sinus syndrome: Septal Pacing for Atrial Fibrillation Suppression Evaluation (SAFE) Study.

    PubMed

    Lau, Chu-Pak; Tachapong, Ngarmukos; Wang, Chun-Chieh; Wang, Jing-Feng; Abe, Haruhiko; Kong, Chi-Woon; Liew, Reginald; Shin, Dong-Gu; Padeletti, Luigi; Kim, You-Ho; Omar, Razali; Jirarojanakorn, Kreingkrai; Kim, Yoon-Nyun; Chen, Mien-Cheng; Sriratanasathavorn, Charn; Munawar, Muhammad; Kam, Ruth; Chen, Jan-Yow; Cho, Yong-Keun; Li, Yi-Gang; Wu, Shu-Lin; Bailleul, Christophe; Tse, Hung-Fat

    2013-08-13

    Atrial-based pacing is associated with lower risk of atrial fibrillation (AF) in sick sinus syndrome compared with ventricular pacing; nevertheless, the impact of site and rate of atrial pacing on progression of AF remains unclear. We evaluated whether long-term atrial pacing at the right atrial (RA) appendage versus the low RA septum with (ON) or without (OFF) a continuous atrial overdrive pacing algorithm can prevent the development of persistent AF. We randomized 385 patients with paroxysmal AF and sick sinus syndrome in whom a pacemaker was indicated to pacing at RA appendage ON (n=98), RA appendage OFF (n=99), RA septum ON (n=92), or RA septum OFF (n=96). The primary outcome was the occurrence of persistent AF (AF documented at least 7 days apart or need for cardioversion). Demographic data were homogeneous across both pacing site (RA appendage/RA septum) and atrial overdrive pacing (ON/OFF). After a mean follow-up of 3.1 years, persistent AF occurred in 99 patients (25.8%; annual rate of persistent AF, 8.3%). Alternative site pacing at the RA septum versus conventional RA appendage (hazard ratio=1.18; 95% confidence interval, 0.79-1.75; P=0.65) or continuous atrial overdrive pacing ON versus OFF (hazard ratio=1.17; 95% confidence interval, 0.79-1.74; P=0.69) did not prevent the development of persistent AF. In patients with paroxysmal AF and sick sinus syndrome requiring pacemaker implantation, an alternative atrial pacing site at the RA septum or continuous atrial overdrive pacing did not prevent the development of persistent AF. URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00419640.

  7. Comparison of total artificial heart and biventricular assist device support as bridge-to-transplantation.

    PubMed

    Cheng, Allen; Trivedi, Jaimin R; Van Berkel, Victor H; Massey, H Todd; Slaughter, Mark S

    2016-10-01

    The use of left ventricular assist devices (LVAD) has increased significantly in the last decade. However, right heart dysfunction remains a problem despite the improved outcomes with continuous-flow LVADs. Surgical options for bridge to transplantation (BTT) in patients with biventricular failure are total artificial heart (TAH) or biventricular support (BiVAD). This study examines the differences in pre- and post-transplantation outcomes and survival in patients with TAH or BiVAD support as BTT. The United Network of Organ Sharing database was retrospectively queried from January 2005 to December 2014 to identify adult patients undergoing heart transplantation (n = 17,022). Patients supported with either TAH (n = 212) or BiVAD (n = 366) at the time of transplantation were evaluated. Pre- and post-transplantation Kaplan-Meier survival curves were examined. Cox regression model was used to study the hazard ratios of the association between TAH versus BiVAD support and post-transplant survival. The median age of the study groups was 49.8 ± 12.9 (TAH) and 47.2 ± 13.9 (BiVAD) years (range 18-74 years). There were more men, 87% versus 74%, in the TAH group (p < 0.0001) with greater body mass index, 27.3 ± 5.2 versus 25.6 ± 4.7 (p < 0.0001), compared to those with BiVADs. Creatinine was higher, 1.7 + 1.2 versus 1.3 + 0.8 mg/dL (p < 0.0001), in the TAH group before transplant. The 30-day, one-, and three-year post-transplantation survival was 88%, 78%, and 67%, respectively, for patients with TAH support versus 93%, 83%, and 73% (p = 0.06) for patients with BiVAD support. Cox regression model shows pre-transplant creatinine (HR = 1.21, p = 0.008) is associated with a lower post-transplant survival. TAH is not associated with a worse post-transplant survival (p = 0.1). There was no difference in wait-list survival in patients supported with TAH or BiVAD (p = 0.8). Although there has been a recent increase in the use of the TAH as BTT, BiVAD support remains a viable option with similar post-transplant survival. © 2016 Wiley Periodicals, Inc.

  8. 42 CFR 460.90 - PACE benefits under Medicare and Medicaid.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE benefits under Medicare and Medicaid. 460.90 Section 460.90 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... FOR THE ELDERLY (PACE) PACE Services § 460.90 PACE benefits under Medicare and Medicaid. If a Medicare...

  9. Safety of the Wearable Cardioverter Defibrillator (WCD) in Patients with Implanted Pacemakers.

    PubMed

    Schmitt, Joern; Abaci, Guezine; Johnson, Victoria; Erkapic, Damir; Gemein, Christopher; Chasan, Ritvan; Weipert, Kay; Hamm, Christian W; Klein, Helmut U

    2017-03-01

    The wearable cardioverter defibrillator (WCD) is an important approach for better risk stratification, applied to patients considered to be at high risk of sudden arrhythmic death. Patients with implanted pacemakers may also become candidates for use of the WCD. However, there is a potential risk that pacemaker signals may mislead the WCD detection algorithm and cause inappropriate WCD shock delivery. The aim of the study was to test the impact of different types of pacing, various right ventricular (RV) lead positions, and pacing modes for potential misleading of the WCD detection algorithm. Sixty patients with implanted pacemakers received the WCD for a short time and each pacing mode (AAI, VVI, and DDD) was tested for at least 30 seconds in unipolar and bipolar pacing configuration. In case of triggering the WCD detection algorithm and starting the sequence of arrhythmia alarms, shock delivery was prevented by pushing of the response buttons. In six of 60 patients (10%), continuous unipolar pacing in DDD mode triggered the WCD detection algorithm. In no patient, triggering occurred with bipolar DDD pacing, unipolar and bipolar AAI, and VVI pacing. Triggering was independent of pacing amplitude, RV pacing lead position, and pulse generator implantation site. Unipolar DDD pacing bears a high risk of false triggering of the WCD detection algorithm. Other types of unipolar pacing and all bipolar pacing modes do not seem to mislead the WCD detection algorithm. Therefore, patients with no reprogrammable unipolar DDD pacing should not become candidates for the WCD. © 2016 Wiley Periodicals, Inc.

  10. Variables affecting the manifestation of and intensity of pacing behavior: A preliminary case study in zoo-housed polar bears.

    PubMed

    Cless, Isabelle T; Lukas, Kristen E

    2017-09-01

    High-speed video analysis was used to quantify two aspects of gait in 10 zoo-housed polar bears. These two variables were then examined as to how they differed in the conditions of pacing versus locomoting for each bear. Percent difference calculations measured the difference between pacing and locomoting data for each bear. We inferred that the higher the percent difference between pacing and locomoting in a given subject, the more intense the pacing may be. The percent difference values were analyzed alongside caregiver survey data defining the locations, frequency, and anticipatory nature of pacing in each bear, as well as each bear's age and sex, to determine whether any variables were correlated. The frequency and intensity of pacing behavior were not correlated. However, location of pacing was significantly correlated both with the subjects' age and whether or not the subject was classified as an anticipatory pacer. Bears appeared to select specific spots within their exhibits to pace, and the location therefore seemed tied to underlying motivation for the behavior. Additionally, bears that were classified in the survey as pacing anticipatorily displayed significantly more intense pacing behavior as quantified by gait analysis. © 2017 Wiley Periodicals, Inc.

  11. Universal ventricular coordinates: A generic framework for describing position within the heart and transferring data.

    PubMed

    Bayer, Jason; Prassl, Anton J; Pashaei, Ali; Gomez, Juan F; Frontera, Antonio; Neic, Aurel; Plank, Gernot; Vigmond, Edward J

    2018-04-01

    Being able to map a particular set of cardiac ventricles to a generic topologically equivalent representation has many applications, including facilitating comparison of different hearts, as well as mapping quantities and structures of interest between them. In this paper we describe Universal Ventricular Coordinates (UVC), which can be used to describe position within any biventricular heart. UVC comprise four unique coordinates that we have chosen to be intuitive, well defined, and relevant for physiological descriptions. We describe how to determine these coordinates for any volumetric mesh by illustrating how to properly assign boundary conditions and utilize solutions to Laplace's equation. Using UVC, we transferred scalar, vector, and tensor data between four unstructured ventricular meshes from three different species. Performing the mappings was very fast, on the order of a few minutes, since mesh nodes were searched in a KD tree. Distance errors in mapping mesh nodes back and forth between meshes were less than the size of an element. Analytically derived fiber directions were also mapped across meshes and compared, showing  < 5° difference over most of the ventricles. The ability to transfer gradients was also demonstrated. Topologically variable structures, like papillary muscles, required further definition outside of the UVC framework. In conclusion, UVC can aid in transferring many types of data between different biventricular geometries. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  12. Left heart bypass support with the Rotaflow Centrifugal Pump® as a bridge to decision and recovery in an adult.

    PubMed

    Kashiwa, Koichi; Nishimura, Takashi; Saito, Aya; Kubo, Hitoshi; Fukaya, Aoi; Tamai, Hisayoshi; Yambe, Tomoyuki; Kyo, Shunei; Ono, Minoru

    2012-06-01

    Since left heart bypass or biventricular circulatory assist with an extracorporeal centrifugal pump as a bridge to decision or recovery sometimes requires long-time support, the long-term durability of extracorporeal centrifugal pumps is crucial. The Rotaflow Centrifugal Pump(®) (MAQUET Cardiopulmonary AG, Hirrlingen, Germany) is one of the centrifugal pumps available for long-term use in Japan. However, there have been few reports of left heart bypass or biventricular circulatory support over the mid-term. This is a case report of left heart bypass support with the Rotaflow Centrifugal Pump(®) as a bridge to decision and recovery for an adult patient who could not be weaned from cardiopulmonary bypass and percutaneous cardiopulmonary support after cardiac surgery. We could confirm that the patient's consciousness level was normal; however, the patient could not be weaned from the left heart bypass support lasting 1 month. Therefore, the circulatory assist device was switched to the extracorporeal Nipro ventricular assist device (VAD). This time, left heart bypass support could be maintained for 30 days using a single Rotaflow Centrifugal Pump(®). There were no signs of hemolysis during left heart bypass support. The Rotaflow Centrifugal Pump(®) itself may be used as a device for a bridge to decision or recovery before using a VAD in cardiogenic shock patients.

  13. High pulmonary vascular resistance in addition to low right ventricular stroke work index effectively predicts biventricular assist device requirement.

    PubMed

    Imamura, Teruhiko; Kinugawa, Koichiro; Kinoshita, Osamu; Nawata, Kan; Ono, Minoru

    2016-03-01

    Although the right ventricular stroke work index (RVSWI) is a good index for RV function, a low RVSWI is not necessarily an indicator for the need for a right ventricular assist device at the time of left VAD implantation. We here aimed to determine a more precise indicator for the need for a biventricular assist device (BiVAD). In total, 116 patients (mean age, 38 ± 14 years), who underwent hemodynamic assessments preoperatively including 12 BiVAD patients, and had been followed at our institute from 2003 to 2015, were included. Multivariate logistic regression analysis indicated that RVSWI and pulmonary vascular resistance (PVR) were independent predictors of BiVAD requirement (P < 0.05 for both). In addition, all patients were classified into 4 groups: (1) normal (RVSWI > 5 g/m, PVR < 3.7 WU), (2) pulmonary hypertension (RVSWI > 5, PVR > 3.7), (3) RV failure (RVSWI < 5, PVR < 3.7), and (4) both pulmonary hypertension and RV failure (RVSWI < 5, PVR > 3.7), and examined. Most of the patients in Group 4 (75 %), with acutely depressed hemodynamics and inflammatory responses in the myocardium, required BiVAD. Overall, patients with BiVAD had a worse survival rate as compared with those with LVAD alone. In conclusion, high PVR in addition to low RVSWI effectively predicts BiVAD requirement.

  14. 42 CFR 460.122 - PACE organization's appeals process.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Rights § 460.122 PACE organization's appeals process. For purposes...

  15. 42 CFR 460.122 - PACE organization's appeals process.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Rights § 460.122 PACE organization's appeals process. For purposes...

  16. 42 CFR 460.170 - Reinstatement in PACE.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Enrollment and Disenrollment § 460.170 Reinstatement in PACE. (a) A previously...

  17. 42 CFR 460.170 - Reinstatement in PACE.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Enrollment and Disenrollment § 460.170 Reinstatement in PACE. (a) A previously...

  18. Effects of pacing magnitudes and forms on bistability width in a modeled ventricular tissue

    NASA Astrophysics Data System (ADS)

    Huang, Xiaodong; Liu, Xuemei; Zheng, Lixian; Mi, Yuanyuan; Qian, Yu

    2013-07-01

    Bistability in periodically paced cardiac tissue is relevant to cardiac arrhythmias and its control. In the present paper, one-dimensional tissue of the phase I Luo-Rudy model is numerically investigated. The effects of various parameters of pacing signals on bistability width are studied. The following conclusions are obtained: (i) Pacing can be classified into two types: pulsatile and sinusoidal types. Pulsatile pacing reduces bistability width as its magnitude is increased. Sinusoidal pacing increases the width as its amplitude is increased. (ii) In a pacing period the hyperpolarizing part plays a more important role than the depolarizing part. Variations of the hyperpolarizing ratio in a period evidently change the width of bistability and its variation tendency. (iii) A dynamical mechanism is proposed to qualitatively explain the phenomena, which reveals the reason for the different effects of pulsatile and sinusoidal pacing on bistability. The methods for changing bistability width by external pacing may help control arrhythmias in cardiology.

  19. Predictors of temporary epicardial pacing wires use after valve surgery

    PubMed Central

    2014-01-01

    Background Although temporary cardiac pacing is infrequently needed, temporary epicardial pacing wires are routinely inserted after valve surgery. As they are associated with infrequent, but life threatening complications, and the decreased need for postoperative pacing in a group of low risk patients; this study aims to identify the predictors of temporary cardiac pacing after valve surgery. Methods A retrospective analysis of data collected prospectively on 400 consecutive valve surgery patients between May 2002 and December 2012 was performed. Patients were grouped according to avoidance or insertion of temporary pacing wires, and were further subdivided according to temporary cardiac pacing need. Multiple logistic regression was used to determine the predictors of temporary cardiac pacing. Results 170 (42.5%) patients did not have insertion of temporary pacing wires and none of them needed temporary pacing. 230 (57.5%) patients had insertion of temporary pacing wires and among these, only 55 (23.9%) required temporary pacing who were compared with the remaining 175 (76.1%) patients in the main analysis. The determinants of temporary cardiac pacing (adjusted odds ratios; 95% confidence interval) were as follows: increased age (1.1; 1.1, 1.3, p = 0.002), New York Heart Association class III- IV (5.6; 1.6, 20.2, p = 0.008) , pulmonary artery pressure ≥ 50 mmHg (22.0; 3.4, 142.7, p = 0.01), digoxin use (8.0; 1.3, 48.8, p = 0.024), multiple valve surgery (13.5; 1.5, 124.0, p = 0.021), aorta cross clamp time ≥ 60 minutes (7.8; 1.6, 37.2, p = 0.010), and valve annulus calcification (7.9; 2.0, 31.7, p = 0.003). Conclusion Although limited by sample size, the present results suggest that routine use of temporary epicardial pacing wires after valve surgery is only necessary for high risk patients. Preoperative identification and aggressive management of predictors of temporary cardiac pacing and the possible modulation of intraoperative techniques can decrease the need of temporary cardiac pacing. Prospective randomized controlled studies on a larger number of patients are necessary to draw solid conclusions regarding the selective use of temporary epicardial pacing wires in valve surgery. PMID:24521215

  20. 42 CFR 460.30 - Program agreement requirement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Program Agreement § 460.30 Program agreement requirement. (a) A PACE organization must...

  1. 42 CFR 460.30 - Program agreement requirement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Program Agreement § 460.30 Program agreement requirement. (a) A PACE organization must...

  2. 42 CFR 460.50 - Termination of PACE program agreement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Sanctions, Enforcement Actions, and Termination § 460.50 Termination of PACE...

  3. 42 CFR 460.50 - Termination of PACE program agreement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Sanctions, Enforcement Actions, and Termination § 460.50 Termination of PACE...

  4. 42 CFR 460.180 - Medicare payment to PACE organizations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Payment § 460.180 Medicare payment to PACE organizations. (a) Principle of...

  5. DefenseLink Special: Travels with Pace, March 2006

    Science.gov Websites

    Us Travels with Pace Chairman of the Joint Chiefs of Staff Marine Gen. Peter Pace U.S. Marine Gen . Peter Pace, chairman of the Joint Chiefs of Staff, speaks to students attending the Turkish War College U.S. Air Force Staff Sgt. D. Myles Cullen Hi-Res Pace Wraps Up Visit to Allied Nations WASHINGTON

  6. Effect of short-term rapid ventricular pacing followed by pacing interruption on arterial blood pressure in healthy pigs and pigs with tachycardiomyopathy.

    PubMed

    Skrzypczak, P; Zyśko, D; Pasławska, U; Noszczyk-Nowak, A; Janiszewski, A; Gajek, J; Nicpoń, J; Kiczak, L; Bania, J; Zacharski, M; Tomaszek, A; Jankowska, E A; Ponikowski, P; Witkiewicz, W

    2014-01-01

    Ventricular tachycardia may lead to haemodynamic deterioration and, in the case of long term persistence, is associated with the development of tachycardiomyopathy. The effect of ventricular tachycardia on haemodynamics in individuals with tachycardiomyopathy, but being in sinus rhythm has not been studied. Rapid ventricular pacing is a model of ventricular tachycardia. The aim of this study was to determine the effect of rapid ventricular pacing on blood pressure in healthy animals and those with tachycardiomyopathy. A total of 66 animals were studied: 32 in the control group and 34 in the study group. The results of two groups of examinations were compared: the first performed in healthy animals (133 examinations) and the second performed in animals paced for at least one month (77 examinations). Blood pressure measurements were taken during chronic pacing--20 min after onset of general anaesthesia, in baseline conditions (20 min after pacing cessation or 20 min after onset of general anaesthesia in healthy animals) and immediately after short-term rapid pacing. In baseline conditions significantly higher systolic and diastolic blood pressure was found in healthy animals than in those with tachycardiomyopathy. During an event of rapid ventricular pacing, a significant decrease in systolic and diastolic blood pressure was found in both groups of animals. In the group of chronically paced animals the blood pressure was lower just after restarting ventricular pacing than during chronic pacing. Cardiovascular adaptation to ventricular tachycardia develops with the length of its duration. Relapse of ventricular tachycardia leads to a blood pressure decrease more pronounced than during chronic ventricular pacing.

  7. Anatomical approach to permanent His bundle pacing: Optimizing His bundle capture.

    PubMed

    Vijayaraman, Pugazhendhi; Dandamudi, Gopi

    2016-01-01

    Permanent His bundle pacing is a physiological alternative to right ventricular pacing. In this article we describe our approach to His bundle pacing in patients with AV nodal and intra-Hisian conduction disease. It is essential for the implanters to understand the anatomic variations of the His bundle course and its effect on the type of His bundle pacing achieved. We describe several case examples to illustrate our anatomical approach to permanent His bundle pacing in this article. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Higher sympathetic nerve activity during ventricular (VVI) than during dual-chamber (DDD) pacing

    NASA Technical Reports Server (NTRS)

    Taylor, J. A.; Morillo, C. A.; Eckberg, D. L.; Ellenbogen, K. A.

    1996-01-01

    OBJECTIVES: We determined the short-term effects of single-chamber ventricular pacing and dual-chamber atrioventricular (AV) pacing on directly measured sympathetic nerve activity. BACKGROUND: Dual-chamber AV cardiac pacing results in greater cardiac output and lower systemic vascular resistance than does single-chamber ventricular pacing. However, it is unclear whether these hemodynamic advantages result in less sympathetic nervous system outflow. METHODS: In 13 patients with a dual-chamber pacemaker, we recorded the electrocardiogram, noninvasive arterial pressure (Finapres), respiration and muscle sympathetic nerve activity (microneurography) during 3 min of underlying basal heart rate and 3 min of ventricular and AV pacing at rates of 60 and 100 beats/min. RESULTS: Arterial pressure was lowest and muscle sympathetic nerve activity was highest at the underlying basal heart rate. Arterial pressure increased with cardiac pacing and was greater with AV than with ventricular pacing (change in mean blood pressure +/- SE: 10 +/- 3 vs. 2 +/- 2 mm Hg at 60 beats/min; 21 +/- 5 vs. 14 +/- 2 mm Hg at 100 beats/min; p < 0.05). Sympathetic nerve activity decreased with cardiac pacing and the decline was greater with AV than with ventricular pacing (60 beats/min -40 +/- 11% vs. -17 +/- 7%; 100 beats/min -60 +/- 9% vs. -48 +/- 10%; p < 0.05). Although most patients showed a strong inverse relation between arterial pressure and muscle sympathetic nerve activity, three patients with severe left ventricular dysfunction (ejection fraction < or = 30%) showed no relation between arterial pressure and sympathetic activity. CONCLUSIONS: Short-term AV pacing results in lower sympathetic nerve activity and higher arterial pressure than does ventricular pacing, indicating that cardiac pacing mode may influence sympathetic outflow simply through arterial baroreflex mechanisms. We speculate that the greater incidence of adverse outcomes in patients treated with single-chamber ventricular rather than dual-chamber pacing may be due in part to increased sympathetic nervous outflow.

  9. Optimizing local capture of atrial fibrillation by rapid pacing: study of the influence of tissue dynamics.

    PubMed

    Uldry, Laurent; Virag, Nathalie; Jacquemet, Vincent; Vesin, Jean-Marc; Kappenberger, Lukas

    2010-12-01

    While successful termination by pacing of organized atrial tachycardias has been observed in patients, rapid pacing of AF can induce a local capture of the atrial tissue but in general no termination. The purpose of this study was to perform a systematic evaluation of the ability to capture AF by rapid pacing in a biophysical model of the atria with different dynamics in terms of conduction velocity (CV) and action potential duration (APD). Rapid pacing was applied during 30 s at five locations on the atria, for pacing cycle lengths in the range 60-110% of the mean AF cycle length (AFCL(mean)). Local AF capture could be achieved using rapid pacing at pacing sites located distal to major anatomical obstacles. Optimal pacing cycle lengths were found in the range 74-80% AFCL(mean) (capture window width: 14.6 ± 3% AFCL(mean)). An increase/decrease in CV or APD led to a significant shrinking/stretching of the capture window. Capture did not depend on AFCL, but did depend on the atrial substrate as characterized by an estimate of its wavelength, a better capture being achieved at shorter wavelengths. This model-based study suggests that a proper selection of the pacing site and cycle length can influence local capture results and that atrial tissue properties (CV and APD) are determinants of the response to rapid pacing.

  10. Right Ventricular Outflow Tract Septal Pacing Is Superior to Right Ventricular Apical Pacing

    PubMed Central

    Zou, Cao; Song, Jianping; Li, Hui; Huang, Xingmei; Liu, Yuping; Zhao, Caiming; Shi, Xin; Yang, Xiangjun

    2015-01-01

    Background The effects of right ventricular apical pacing (RVAP) and right ventricular outflow tract (RVOT) septal pacing on atrial and ventricular electrophysiology have not been thoroughly compared. Methods and Results To identify a more favorable pacing strategy with fewer adverse effects, 80 patients who had complete atrioventricular block with normal cardiac function and who were treated with either RVAP (n=42) or RVOT septal pacing (n=38) were recruited after an average of 2 years of follow‐up. The data from electrocardiography and echocardiography performed before pacemaker implantation and at the end of follow‐up were collected. The patients in the RVOT septal pacing and RVAP groups showed similar demographic and clinical characteristics before pacing treatments. After a mean follow‐up of 2 years, the final maximum P‐wave duration; P‐wave dispersion; Q‐, R‐, and S‐wave complex duration; left atrial volume index; left ventricular end‐systolic diameter; ratio of transmitral early diastolic filling velocity to mitral annular early diastolic velocity; and interventricular mechanical delay in the RVOT septal pacing group were significantly less than those in the RVAP group (P<0.05). The final left ventricular ejection fraction of the RVOT septal pacing group was significantly higher than that of the RVAP group (P<0.05). Conclusions Compared with RVAP, RVOT septal pacing has fewer adverse effects regarding atrial electrical activity and structure in patients with normal cardiac function. PMID:25896891

  11. EM connectomics reveals axonal target variation in a sequence-generating network

    PubMed Central

    Narayanan, Rajeevan T; Svara, Fabian; Egger, Robert; Oberlaender, Marcel; Denk, Winfried; Long, Michael A

    2017-01-01

    The sequential activation of neurons has been observed in various areas of the brain, but in no case is the underlying network structure well understood. Here we examined the circuit anatomy of zebra finch HVC, a cortical region that generates sequences underlying the temporal progression of the song. We combined serial block-face electron microscopy with light microscopy to determine the cell types targeted by HVC(RA) neurons, which control song timing. Close to their soma, axons almost exclusively targeted inhibitory interneurons, consistent with what had been found with electrical recordings from pairs of cells. Conversely, far from the soma the targets were mostly other excitatory neurons, about half of these being other HVC(RA) cells. Both observations are consistent with the notion that the neural sequences that pace the song are generated by global synaptic chains in HVC embedded within local inhibitory networks. DOI: http://dx.doi.org/10.7554/eLife.24364.001 PMID:28346140

  12. 42 CFR 460.24 - Limit on number of PACE program agreements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.24 Limit on number of...

  13. 42 CFR 460.24 - Limit on number of PACE program agreements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.24 Limit on number of...

  14. Interatrial septum versus right atrial appendage pacing for prevention of atrial fibrillation : A meta-analysis of randomized controlled trials.

    PubMed

    Zhang, L; Jiang, H; Wang, W; Bai, J; Liang, Y; Su, Y; Ge, J

    2017-07-28

    Interatrial septum (IAS) pacing seems to be a promising strategy for the prevention of atrial fibrillation (AF); however, studies have yielded conflicting results. This meta-analysis was to compare IAS with right atrial appendage (RAA) pacing on the prevention of postpacing AF occurrence. Pubmed, MEDLINE, EMBASE and Web of Science databases were searched through October 2016 for randomized controlled trials comparing IAS with RAA pacing on the prevention of AF. Data concerning study design, patient characteristics and outcomes were extracted. Risk ratio (RR), weighted mean differences (WMD) or standardized mean differences (SMD) were calculated using fixed or random effects models. A total of 12 trials involving 1146 patients with dual-chamber pacing were included. Although IAS was superior to RAA pacing in terms of reducing the number of AF episodes (SMD = -0.29, P = 0.05), AF burden (SMD = -0.41, P = 0.008) and P -wave duration (WMD = -34.45 ms, P < 0.0001), neither permanent AF occurrence (RR = 0.94, P = 0.58) nor recurrences of AF (RR = 0.88, P = 0.36) were reduced by IAS pacing. Nevertheless, no differences were observed concerning all-cause death (RR = 1.04, P = 0.88), procedure-related events (RR = 1.17, P = 0.69) and pacing parameters between IAS and RAA pacing in the follow-up period. IAS pacing is safe and as well tolerated as RAA pacing. Although IAS pacing may fail to prevent permanent AF occurrence and recurrences of AF, it is able to not only improve interatrial conduction, but also reduce AF burden.

  15. Effects of septal pacing on P wave characteristics: the value of three-dimensional echocardiography.

    PubMed

    Szili-Torok, Tamas; Bruining, Nico; Scholten, Marcoen; Kimman, Geert-Jan; Roelandt, Jos; Jordaens, Luc

    2003-01-01

    Interatrial septum (IAS) pacing has been proposed for the prevention of paroxysmal atrial fibrillation. IAS pacing is usually guided by fluoroscopy and P wave analysis. The authors have developed a new approach for IAS pacing using intracardiac echocardiography (ICE), and examined its effects on P wave characteristics. Cross-sectional images are acquired during pullback of the ICE transducer from the superior vena cava into the inferior vena cava by an electrocardiogram- and respiration-gated technique. The right atrium and IAS are then three-dimensionally reconstructed, and the desired pacing site is selected. After lead placement and electrical testing, another three-dimensional reconstruction is performed to verify the final lead position. The study included 14 patients. IAS pacing was achieved at seven suprafossal (SF) and seven infrafossal (IF) lead locations, all confirmed by three-dimensional imaging. IAS pacing resulted in a significant reduction of P wave duration as compared to sinus rhythm (99.7 +/- 18.7 vs 140.4 +/- 8.8 ms; P < 0.01). SF pacing was associated with a greater reduction of P wave duration than IF pacing (56.1 +/- 9.9 vs 30.2 +/- 13.6 ms; P < 0.01). P wave dispersion remained unchanged during septal pacing as compared to sinus rhythm (21.4 +/- 16.1 vs 13.5 +/- 13.9 ms; NS). Three-dimensional intracardiac echocardiography can be used to guide IAS pacing. SF pacing was associated with a greater decrease in P wave duration, suggesting that it is a preferable location to decrease interatrial conduction delay.

  16. Pacing a data transfer operation between compute nodes on a parallel computer

    DOEpatents

    Blocksome, Michael A [Rochester, MN

    2011-09-13

    Methods, systems, and products are disclosed for pacing a data transfer between compute nodes on a parallel computer that include: transferring, by an origin compute node, a chunk of an application message to a target compute node; sending, by the origin compute node, a pacing request to a target direct memory access (`DMA`) engine on the target compute node using a remote get DMA operation; determining, by the origin compute node, whether a pacing response to the pacing request has been received from the target DMA engine; and transferring, by the origin compute node, a next chunk of the application message if the pacing response to the pacing request has been received from the target DMA engine.

  17. Pacing in Olympic track races: competitive tactics versus best performance strategy.

    PubMed

    Thiel, Christian; Foster, Carl; Banzer, Winfried; De Koning, Jos

    2012-01-01

    The purpose of this study was to describe pacing strategies in the 800 to 10,000-m Olympic finals. We asked 1) if Olympic finals differed from World Records, 2) how variable the pace was, 3) whether runners faced catastrophic events, and 4) for the winning strategy. Publically available data from the Beijing 2008 Olympic Games gathered by four transponder antennae under the 400-m track were analysed to extract descriptors of pacing strategies. Individual pacing patterns of 133 finalists were visualised using speed by distance plots. Six of eight plots differed from the patterns reported for World Records. The coefficient of running speed variation was 3.6-11.4%. In the long distance finals, runners varied their pace every 100 m by a mean 1.6-2.7%. Runners who were 'dropped' from the field achieved a stable running speed and displayed an endspurt. Top contenders used variable pacing strategies to separate themselves from the field. All races were decided during the final lap. Olympic track finalists employ pacing strategies which are different from World Record patterns. The observed micro- and macro-variations of pace may have implications for training programmes. Dropping off the pace of the leading group is an active step, and the result of interactive psychophysiological decision making.

  18. Meta-Analysis of Single-Case Research Design Studies on Instructional Pacing.

    PubMed

    Tincani, Matt; De Mers, Marilyn

    2016-11-01

    More than four decades of research on instructional pacing has yielded varying and, in some cases, conflicting findings. The purpose of this meta-analysis was to synthesize single-case research design (SCRD) studies on instructional pacing to determine the relative benefits of brisker or slower pacing. Participants were children and youth with and without disabilities in educational settings, excluding higher education. Tau-U, a non-parametric statistic for analyzing data in SCRD studies, was used to determine effect size estimates. The article extraction yielded 13 instructional pacing studies meeting contemporary standards for high quality SCRD research. Eleven of the 13 studies reported small to large magnitude effects when two or more pacing parameters were compared, suggesting that instructional pacing is a robust instructional variable. Brisker instructional pacing with brief inter-trial interval (ITI) produced small increases in correct responding and medium to large reductions in challenging behavior compared with extended ITI. Slower instructional pacing with extended wait-time produced small increases in correct responding, but also produced small increases in challenging behavior compared with brief wait-time. Neither brief ITI nor extended wait-time meets recently established thresholds for evidence-based practice, highlighting the need for further instructional pacing research. © The Author(s) 2016.

  19. A Case of Loeffler's Endocarditis Associated with Churg-Strauss Syndrome

    PubMed Central

    Seo, Jeong-Sook; Kim, Dae-Hee; Kang, Duk-Hyun; Song, Jae-Kwan

    2010-01-01

    Loeffler's endocarditis is generally caused by hypereosinophilic syndrome. It is a restrictive cardiomyopathy characterized with eosinophilia and eosionophilic penetration leading to the fibrous thickening of endocardium of both ventricles, apical obliteration and heart failure. We report a case of a 23-year-old male with Loeffler's endocarditis caused by Churg-Strauss syndrome. The echocardiogram showed that biventricular failure with large thrombus in left ventricle. His symptoms and typical echocardiographic findings markedly improved within 2 months after treatment for Churg-Strauss syndrome. PMID:20661332

  20. A first step beyond traditional boundaries: destination therapy with the SynCardia total artificial heart.

    PubMed

    Spiliopoulos, Sotirios; Koerfer, Reiner; Tenderich, Gero

    2014-06-01

    The SynCardia total artificial heart is currently used as a bridge to transplantation therapy in cases of irreversible, acute or chronic, biventricular heart failure. We describe the implementation of this technology in the context of destination therapy in a patient with an end-stage heart failure on grounds of primary amyloidosis. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Relationship between left atrium catheter contact force and pacing threshold.

    PubMed

    Barrio-López, Teresa; Ortiz, Mercedes; Castellanos, Eduardo; Lázaro, Carla; Salas, Jefferson; Madero, Sergio; Almendral, Jesús

    2017-08-01

    The purpose of this study is to analyze the relationship between contact force (CF) and pacing threshold in left atrium (LA). Six to ten LA sites were studied in 28 consecutive patients with atrial fibrillation undergoing pulmonary vein isolation. Median CF, bipolar and unipolar electrogram voltage, impedance, and bipolar and unipolar thresholds for consistent constant capture and for consistent intermittent capture were measured at each site. Pacing threshold measurements were performed at 188 LA sites. Both unipolar and bipolar pacing thresholds correlated significantly with median CF; however, unipolar pacing threshold correlated better (unipolar: Pearson R -0.45; p < 0.001; Spearman Rho -0.62; p < 0.001, bipolar: Pearson R -0.39; p < 0.001; Spearman Rho -0.52; p < 0.001). Consistent constant capture threshold had better correlation with median CF than consistent intermittent capture threshold for both unipolar and bipolar pacing (Pearson R -0.45; p < 0.001 and Spearman Rho -0.62; p < 0.001 vs. Pearson R -0.35; p < 0.001; Spearman Rho -0.52; p < 0.001). The best pacing threshold cutoff point to detect a good CF (>10 g) was 3.25 mA for unipolar pacing with 69% specificity and 73% sensitivity. Both increased to 80% specificity and 74% sensitivity for sites with normal bipolar voltage and a pacing threshold cutoff value of 2.85 mA. Pacing thresholds correlate with CF in human not previously ablated LA. Since the combination of a normal bipolar voltage and a unipolar pacing threshold <2.85 mA provide reasonable parameters of validity, pacing threshold could be of interest as a surrogate for CF in LA.

  2. Risk perception influences athletic pacing strategy.

    PubMed

    Micklewright, Dominic; Parry, David; Robinson, Tracy; Deacon, Greg; Renfree, Andrew; St Clair Gibson, Alan; Matthews, William J

    2015-05-01

    The objective of this study is to examine risk taking and risk perception associations with perceived exertion, pacing, and performance in athletes. Two experiments were conducted in which risk perception was assessed using the domain-specific risk taking (DOSPERT) scale in 20 novice cyclists (experiment 1) and 32 experienced ultramarathon runners (experiment 2). In experiment 1, participants predicted their pace and then performed a 5-km maximum effort cycling time trial on a calibrated Kingcycle mounted bicycle. Split times and perceived exertion were recorded every kilometer. In experiment 2, each participant predicted their split times before running a 100-km ultramarathon. Split times and perceived exertion were recorded at seven checkpoints. In both experiments, higher and lower risk perception groups were created using median split of DOSPERT scores. In experiment 1, pace during the first kilometer was faster among lower risk perceivers compared with higher risk perceivers (t(18) = 2.0, P = 0.03) and faster among higher risk takers compared with lower risk takers (t(18) = 2.2, P = 0.02). Actual pace was slower than predicted pace during the first kilometer in both the higher risk perceivers (t(9) = -4.2, P = 0.001) and lower risk perceivers (t(9) = -1.8, P = 0.049). In experiment 2, pace during the first 36 km was faster among lower risk perceivers compared with higher risk perceivers (t(16) = 2.0, P = 0.03). Irrespective of risk perception group, actual pace was slower than predicted pace during the first 18 km (t(16) = 8.9, P < 0.001) and from 18 to 36 km (t(16) = 4.0, P < 0.001). In both experiments, there was no difference in performance between higher and lower risk perception groups. Initial pace is associated with an individual's perception of risk, with low perceptions of risk being associated with a faster starting pace. Large differences between predicted and actual pace suggest that the performance template lacks accuracy, perhaps indicating greater reliance on momentary pacing decisions rather than preplanned strategy.

  3. The effect of visitor number and spice provisioning in pacing expression by jaguars evaluated through a case study.

    PubMed

    Vidal, L S; Guilherme, F R; Silva, V F; Faccio, M C S R; Martins, M M; Briani, D C

    2016-06-01

    Captive animals exhibit stereotypic pacing in response to multiple causes, including the inability to escape from human contact. Environmental enrichment techniques can minimize pacing expression. By using an individual-based approach, we addressed whether the amount of time two males and a female jaguar (Panthera onca) devote to pacing varied with the number of visitors and tested the effectiveness of cinnamon and black pepper in reducing pacing. The amount of time that all jaguars engaged in pacing increased significantly with the number of visitors. Despite the difference between the males regarding age and housing conditions, both devoted significantly less time to pacing following the addition of both spices, which indicates their suitability as enrichment techniques. Mean time devoted to pacing among the treatments did not differ for the female. Our findings pointed out to the validity of individual-based approaches, as they can reveal how suitable olfactory stimuli are to minimizing stereotypies irrespective of particular traits.

  4. The efficacy of self-paced study in multitrial learning.

    PubMed

    de Jonge, Mario; Tabbers, Huib K; Pecher, Diane; Jang, Yoonhee; Zeelenberg, René

    2015-05-01

    In 2 experiments we investigated the efficacy of self-paced study in multitrial learning. In Experiment 1, native speakers of English studied lists of Dutch-English word pairs under 1 of 4 imposed fixed presentation rate conditions (24 × 1 s, 12 × 2 s, 6 × 4 s, or 3 × 8 s) and a self-paced study condition. Total study time per list was equated for all conditions. We found that self-paced study resulted in better recall performance than did most of the fixed presentation rates, with the exception of the 12 × 2 s condition, which did not differ from the self-paced condition. Additional correlational analyses suggested that the allocation of more study time to difficult pairs than to easy pairs might be a beneficial strategy for self-paced learning. Experiment 2 was designed to test this hypothesis. In 1 condition, participants studied word pairs in a self-paced fashion without any restrictions. In the other condition, participants studied word pairs in a self-paced fashion but total study time per item was equated. The results showed that allowing self-paced learners to freely allocate study time over items resulted in better recall performance. (c) 2015 APA, all rights reserved).

  5. 42 CFR 460.102 - Interdisciplinary team.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Interdisciplinary team. 460.102 Section 460.102... ELDERLY (PACE) PACE Services § 460.102 Interdisciplinary team. (a) Basic requirement. A PACE organization must meet the following requirements: (1) Establish an interdisciplinary team at each Pace center to...

  6. 42 CFR 460.102 - Interdisciplinary team.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Interdisciplinary team. 460.102 Section 460.102... ELDERLY (PACE) PACE Services § 460.102 Interdisciplinary team. (a) Basic requirement. A PACE organization must meet the following requirements: (1) Establish an interdisciplinary team at each Pace center to...

  7. 42 CFR 460.102 - Interdisciplinary team.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Interdisciplinary team. 460.102 Section 460.102... ELDERLY (PACE) PACE Services § 460.102 Interdisciplinary team. (a) Basic requirement. A PACE organization must meet the following requirements: (1) Establish an interdisciplinary team at each Pace center to...

  8. 42 CFR 460.102 - Interdisciplinary team.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Interdisciplinary team. 460.102 Section 460.102... ELDERLY (PACE) PACE Services § 460.102 Interdisciplinary team. (a) Basic requirement. A PACE organization must meet the following requirements: (1) Establish an interdisciplinary team at each Pace center to...

  9. 42 CFR 460.102 - Interdisciplinary team.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Interdisciplinary team. 460.102 Section 460.102... ELDERLY (PACE) PACE Services § 460.102 Interdisciplinary team. (a) Basic requirement. A PACE organization must meet the following requirements: (1) Establish an interdisciplinary team at each Pace center to...

  10. Spatial resolution of pace mapping of idiopathic ventricular tachycardia/ectopy originating in the right ventricular outflow tract.

    PubMed

    Bogun, Frank; Taj, Majid; Ting, Michael; Kim, Hyungjin Myra; Reich, Stephen; Good, Eric; Jongnarangsin, Krit; Chugh, Aman; Pelosi, Frank; Oral, Hakan; Morady, Fred

    2008-03-01

    Pace mapping has been used to identify the site of origin of focal ventricular arrhythmias. The spatial resolution of pace mapping has not been adequately quantified using currently available three-dimensional mapping systems. The purpose of this study was to determine the spatial resolution of pace mapping in patients with idiopathic ventricular tachycardia or premature ventricular contractions originating in the right ventricular outflow tract. In 16 patients with idiopathic ventricular tachycardia/ectopy from the right ventricular outflow tract, comparisons and classifications of pace maps were performed by two observers (good pace map: match >10/12 leads; inadequate pace map: match < or =10/12 leads) and a customized MATLAB 6.0 program (assessing correlation coefficient and normalized root mean square of the difference (nRMSd) between test and template signals). With an electroanatomic mapping system, the correlation coefficient of each pace map was correlated with the distance between the pacing site and the effective ablation site. The endocardial area within the 10-ms activation isochrone was measured. The ablation procedure was effective in all patients. Sites with good pace maps had a higher correlation coefficient and lower nRMSd than sites with inadequate pace maps (correlation coefficient: 0.96 +/- 0.03 vs 0.76 +/- 0.18, P <.0001; nRMSd: 0.41 +/- 0.16 vs 0.89 +/- 0.39, P <.0001). Using receiver operating characteristic curves, appropriate cutoff values were >0.94 for correlation coefficient (sensitivity 81%, specificity 89%) and < or =0.54 for nRMSd (sensitivity 76%, specificity 80%). Good pace maps were located a mean of 7.3 +/- 5.0 mm from the effective ablation site and had a mean activation time of -24 +/- 7 ms. However, in 3 (18%) of 16 patients, the best pace map was inadequate at the effective ablation site, with an endocardial activation time at these sites of -25 +/- 12 ms. Pace maps with correlation coefficient > or =0.94 were confined to an area of 1.8 +/- 0.6 cm2. The 10-ms isochrone measured 1.2 +/- 0.7 cm2. The spatial resolution of a good pace map for targeting ventricular tachycardia/ectopy is 1.8 cm2 in the right ventricular outflow tract and therefore is inferior to the spatial resolution of activation mapping as assessed by isochronal activation. In approximately 20% of patients, pace mapping is unreliable in identifying the site of origin, possibly due a deeper site of origin and preferential conduction via fibers connecting the focus to the endocardial surface.

  11. Comparison of DDD versus VVIR pacing modes in elderly patients with atrioventricular block.

    PubMed

    Kılıçaslan, Barış; Vatansever Ağca, Fahriye; Kılıçaslan, Esin Evren; Kınay, Ozan; Tigen, Kürşat; Cakır, Cayan; Nazlı, Cem; Ergene, Oktay

    2012-06-01

    Dual-chamber pacing is believed to have an advantage over single-chamber ventricular pacing. The aim of this study was to determine whether elderly patients who have implanted pacemakers for complete atrioventricular block gain significant benefits from dual-chamber (DDD) pacemakers compared with single chamber ventricular (VVIR) pacemakers. This study was designed as a randomized, two-period crossover study-each pacing mode was maintained for 1 month. Thirty patients (16 men, mean age 68.87 ± 6.89 years) with implanted DDD pacemakers were submitted to a standard protocol, which included an interview, pacemaker syndrome assessment, health related quality of life (HRQoL) questionnaires assessed by an SF-36 test, 6-minute walk test (6MWT), and transthoracic echocardiographic examinations. All of these parameters were obtained on both DDD and VVIR mode pacing. Paired data were compared. HRQoL scores were similar, and 6MWT results did not differ between the two groups. VVIR pacing elicited significant enlargement of the left atrium and impaired left ventricular diastolic functions as compared with DDD pacing. Two patients reported subclinical pacemaker syndrome, but this was not statistically significant. Our study revealed that in active elderly patients with complete heart block, DDD pacing and VVIR pacing yielded similar improvements in QoL and exercise performance. However, after a short follow-up period, we noted that VVIR pacing caused significant left atrial enlargement and impaired left ventricular diastolic functions.

  12. Symptoms of chronic fatigue syndrome/myalgic encephalopathy are not determined by activity pacing when measured by the chronic pain coping inventory.

    PubMed

    Thompson, D P; Antcliff, D; Woby, S R

    2018-03-01

    Chronic fatigue syndrome/myalgic encephalopathy (CFS/ME) is a chronic illness which can cause significant fatigue, pain and disability. Activity pacing is frequently advocated as a beneficial coping strategy, however, it is unclear whether pacing is significantly associated with symptoms in people with CFS/ME. The first aim of this study was therefore to explore the cross-sectional associations between pacing and levels of pain, disability and fatigue. The second aim was to explore whether changes in activity pacing following participation in a symptom management programme were related to changes in clinical outcomes. Cross-sectional study exploring the relationships between pacing, pain, disability and fatigue (n=114) and pre-post treatment longitudinal study of a cohort of patients participating in a symptom management programme (n=35). Out-patient physiotherapy CFS/ME service. One-hundred and fourteen adult patients with CFS/ME. Pacing was assessed using the chronic pain coping inventory. Pain was measured using a Numeric Pain Rating Scale, fatigue with the Chalder Fatigue Scale and disability with the Fibromyalgia Impact Questionnaire. No significant associations were observed between activity pacing and levels of pain, disability or fatigue. Likewise, changes in pacing were not significantly associated with changes in pain, disability or fatigue following treatment. Activity pacing does not appear to be a significant determinant of pain, fatigue or disability in people with CFS/ME when measured with the chronic pain coping index. Consequently, the utility and measurement of pacing require further investigation. Copyright © 2017 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  13. Influence of pacing site characteristics on response to cardiac resynchronization therapy.

    PubMed

    Wong, Jorge A; Yee, Raymond; Stirrat, John; Scholl, David; Krahn, Andrew D; Gula, Lorne J; Skanes, Allan C; Leong-Sit, Peter; Klein, George J; McCarty, David; Fine, Nowell; Goela, Aashish; Islam, Ali; Thompson, Terry; Drangova, Maria; White, James A

    2013-07-01

    Transmural scar occupying left ventricular (LV) pacing regions has been associated with reduced response to cardiac resynchronization therapy (CRT). However, spatial influences of lead tip delivery relative to scar at both pacing sites remain poorly explored. This study evaluated scar distribution relative to LV and right ventricular (RV) lead tip placement through coregistration of late gadolinium enhancement MRI and cardiac computed tomographic (CT) findings. Influences on CRT response were assessed by serial echocardiography. Sixty patients receiving CRT underwent preimplant late gadolinium enhancement MRI, postimplant cardiac CT, and serial echocardiography. Blinded segmental evaluations of mechanical delay, percentage scar burden, and lead tip location were performed. Response to CRT was defined as a reduction in LV end-systolic volume ≥15% at 6 months. The mean age and LV ejection fraction were 64±9 years and 25±7%, respectively. Mean scar volume was higher among CRT nonresponders for both the LV (23±23% versus 8±14% [P=0.01]) and RV pacing regions (40±32% versus 24±30% [P=0.04]). Significant pacing region scar was identified in 13% of LV pacing regions and 37% of RV pacing regions. Absence of scar in both regions was associated with an 81% response rate compared with 55%, 25%, and 0%, respectively, when the RV, LV, or both pacing regions contained scar. LV pacing region dyssynchrony was not predictive of response. Myocardial scar occupying the LV pacing region is associated with nonresponse to CRT. Scar occupying the RV pacing region is encountered at higher frequency and seems to provide a more intermediate influence on CRT response.

  14. DDD versus VVIR pacing in patients, ages 70 and over, with complete heart block.

    PubMed

    Ouali, Sana; Neffeti, Elyes; Ghoul, Karima; Hammas, Sami; Kacem, Slim; Gribaa, Rim; Remedi, Fahmi; Boughzela, Essia

    2010-05-01

    Dual-chamber pacing is believed to have an advantage over single-chamber ventricular pacing. The aim of the study was to determine whether elderly patients with implanted pacemaker for complete atrioventricular block gain significant benefit from dual-chamber (DDD) compared with single-chamber ventricular demand (VVIR). The study was designed as a double-blind randomized two-period crossover study-each pacing mode was maintained for 3 months. Thirty patients (eight men, mean age 76.5 +/- 4.3 years) with implanted PM were submitted to a standard protocol, which included an interview, functional class assessment, quality of life (QoL) questionnaires, 6-minute walk test, and transthoracic echocardiographic examinations. QoL was measured by the SF-36. All these parameters were obtained on DDD mode pacing and VVIR mode pacing. Paired data were compared. QoL was significantly different between the two groups and showed the best values in DDD. Overall, no patient preferred VVIR mode, 18 preferred DDD mode, and 12 expressed no preference. No differences in mean walking distances were observed between patients with single-chamber and dual-chamber pacing. VVI pacing elicited marked decrease in left ventricle ejection fraction and significant enlargement of the left atrium. DDD pacing resulted in significant increase of the peak systolic velocities in lateral mitral annulus and septal mitral annulus. Early diastolic velocities on both sides of mitral annulus did not change. In active elderly patients with complete heart block, DDD pacing is associated with improved quality of life and systolic ventricular function compared with VVI pacing.

  15. 42 CFR 460.186 - PACE premiums.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false PACE premiums. 460.186 Section 460.186 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE...

  16. "U-Pace" Instruction: Improving Student Success by Integrating Content Mastery and Amplified Assistance

    ERIC Educational Resources Information Center

    Reddy, Diane M.; Pfeiffer, Heidi M.; Fleming, Raymond; Ports, Katie A.; Pedrick, Laura E.; Barnack-Tavlaris, Jessica L.; Jirovec, Danielle L.; Helion, Alicia M.; Swain, Rodney A.

    2013-01-01

    "U-Pace," an instructional intervention, has potential for widespread implementation because student behavior recorded in any learning management system is used by "U-Pace" instructors to tailor coaching of student learning based on students' strengths and motivations. "U-Pace" utilizes an online learning environment…

  17. Unintended Outcomes of University-Community Partnerships: Building Organizational Capacity with PACE International Partners

    ERIC Educational Resources Information Center

    Lloyd, Kate; Clark, Lindie; Hammersley, Laura; Baker, Michaela; Rawlings-Sanaei, Felicity; D'ath, Emily

    2015-01-01

    Professional and Community Engagement (PACE) at Macquarie University provides experiential opportunities for students and staff to contribute to more just, inclusive and sustainable societies by engaging in activities with partner organizations. PACE International offers a range of opportunities with partners overseas. Underpinning PACE is a…

  18. A Sequential Phase 2b Trial Design for Evaluating Vaccine Efficacy and Immune Correlates for Multiple HIV Vaccine Regimens

    PubMed Central

    Gilbert, Peter B.; Grove, Douglas; Gabriel, Erin; Huang, Ying; Gray, Glenda; Hammer, Scott M.; Buchbinder, Susan P.; Kublin, James; Corey, Lawrence; Self, Steven G.

    2012-01-01

    Five preventative HIV vaccine efficacy trials have been conducted over the last 12 years, all of which evaluated vaccine efficacy (VE) to prevent HIV infection for a single vaccine regimen versus placebo. Now that one of these trials has supported partial VE of a prime-boost vaccine regimen, there is interest in conducting efficacy trials that simultaneously evaluate multiple prime-boost vaccine regimens against a shared placebo group in the same geographic region, for accelerating the pace of vaccine development. This article proposes such a design, which has main objectives (1) to evaluate VE of each regimen versus placebo against HIV exposures occurring near the time of the immunizations; (2) to evaluate durability of VE for each vaccine regimen showing reliable evidence for positive VE; (3) to expeditiously evaluate the immune correlates of protection if any vaccine regimen shows reliable evidence for positive VE; and (4) to compare VE among the vaccine regimens. The design uses sequential monitoring for the events of vaccine harm, non-efficacy, and high efficacy, selected to weed out poor vaccines as rapidly as possible while guarding against prematurely weeding out a vaccine that does not confer efficacy until most of the immunizations are received. The evaluation of the design shows that testing multiple vaccine regimens is important for providing a well-powered assessment of the correlation of vaccine-induced immune responses with HIV infection, and is critically important for providing a reasonably powered assessment of the value of identified correlates as surrogate endpoints for HIV infection. PMID:23181167

  19. Elevated Endomyocardial Biopsy Macrophage-Related Markers in Intractable Myocardial Diseases.

    PubMed

    Hayashi, Yuka; Hanawa, Haruo; Jiao, Shuang; Hasegawa, Go; Ohno, Yukako; Yoshida, Kaori; Suzuki, Tomoyasu; Kashimura, Takeshi; Obata, Hiroaki; Tanaka, Komei; Watanabe, Tohru; Minamino, Tohru

    2015-12-01

    Tissue macrophages can be activated by endogenous danger signals released from cells that are stressed or injured, leading to infiltration of inflammatory macrophages and neutrophils. We postulated that macrophage-related markers might be closely associated with the existence of endogenous danger signals, reflecting ongoing tissue injury in the absence of foreign substances. This study was designed to assess the ability of macrophage-related markers in endomyocardial biopsies to predict ongoing cardiac injury in non-inflammatory myocardial diseases. We examined levels of macrophage-related markers (CD68, CD163, CD45) in endomyocardial biopsies from patients (n = 86) with various myocardial diseases by quantitative reverse transcription-polymerase chain reaction (n = 78) and immunohistochemistry (n = 56). Thirty-three patients without inflammatory cardiac disease such as myocarditis and sarcoidosis were classified as "improved" or "non-improved" defined as a 10% increase in left ventricular ejection fraction by echocardiograph and a value greater than 30% at the time of follow-up. All macrophage-related (MacR) markers levels were not higher in non-improved dilated cardiomyopathy (DCM) patients than improved patients. However, patients with cardiac amyloidosis, cardiac Fabry disease, mitochondrial cardiomyopathy, and biventricular arrhythmogenic right ventricular cardiomyopathy (ARVC), which were categorized as "non-improvement diseases," had elevated macrophage-related markers compared to improved patients. Macrophage-related markers levels were increased in endomyocardial biopsy samples of patients with intractable myocardial diseases such as amyloidosis, mitochondrial disease, Fabry disease, and biventricular ARVC.

  20. Cardiac mechanics and heart rate variability in patients with systemic sclerosis: the association that we should not miss.

    PubMed

    Zlatanovic, Maja; Tadic, Marijana; Celic, Vera; Ivanovic, Branislava; Stevanovic, Ana; Damjanov, Nemanja

    2017-01-01

    We aimed to determine left ventricular (LV) and right ventricular (RV) structure, function and mechanics, as well as heart rate variability (HRV), and their relationship, in patients with systemic sclerosis (SSc). The study included 41 SSc patients and 30 age-matched healthy volunteers. All the patients underwent clinical examination, serological tests, pulmonary function testing, 24-h Holter monitoring and complete two-dimensional echocardiography including strain analysis. The parameters of LV structure (interventricular septum thickness and LV mass index) and RV structure (RV wall thickness) were significantly higher in SSc patients. LV and RV diastolic function (estimated by mitral and tricuspid E/e' ratio) was significantly impaired in SSc group comparing with the healthy controls. LV and RV longitudinal function was significantly deteriorated in SSc patients. LV circumferential strain was also significantly lower in SSc group, whereas LV radial strain was similar between the observed groups. All parameters of time and frequency domain of HRV were decreased in SSc patients. LV and RV cardiac remodeling parameters, particularly diastolic function and longitudinal strain, were associated with HRV indices without regard to the main demographic or the clinical and echocardiographic characteristics. Rodnan Skin Score was also independently associated with biventricular cardiac remodeling in SSc patients. LV and RV structure, function and mechanics, as well as autonomic nervous function, were significantly impaired in SSc patients. There is the significant association between biventricular cardiac remodeling and autonomic function in these patients, which could be useful for their everyday clinical assessment.

  1. Complications leading to surgical revision in implantable cardioverter defibrillator patients: comparison of patients with single-chamber, dual-chamber, and biventricular devices.

    PubMed

    Duray, Gabor Z; Schmitt, Joern; Cicek-Hartvig, Sule; Hohnloser, Stefan H; Israel, Carsten W

    2009-03-01

    Implantable cardioverter defibrillator (ICD) technology has become more complex, particularly with respect to biventricular resynchronization devices. The incidence of hardware-related complications in single (SC)-, dual (DC)-, and triple (BiV)-chamber devices requiring surgical revision has not been investigated systematically. We analysed data from consecutive ICD recipients implanted between January 2000 and December 2007 with respect to the need of surgical re-intervention for device- or lead-related complications. Generator exchanges due to normal battery depletion were not considered. From 816 patients (81% male, 69% ischaemic cardiomyopathy, 48% secondary prevention ICDs) followed for 31 +/- 24 months (2118 cumulative patient-years), 98 patients underwent 110 revisions (5.2% per patient-year). Complications included lead-related revision procedures in 81 cases and generator-related problems in 29 cases. The annual incidence of surgical revision due to complications was 11.8% in BiV compared with 4.9% in SC and 4.1% in DC patients (P = 0.002). This higher revision rate was mainly caused by lead-related complications. Implantation of a BiV system was an independent risk factor of the need for surgical revision (relative risk 2.37, 95% confidence interval 1.38-4.04). Even with long-lasting operator experience, complications requiring surgical revision remain a clinically important problem of ICD therapy. The incidence of complications is significantly higher in BiV resynchronization devices than in SC and DC systems.

  2. Comparative Effect of Levosimendan and Milrinone in Cardiac Surgery Patients With Pulmonary Hypertension and Left Ventricular Dysfunction.

    PubMed

    Mishra, Abhi; Kumar, Bhupesh; Dutta, Vikas; Arya, V K; Mishra, Anand Kumar

    2016-06-01

    To compare the effects of levosimendan with milrinone in cardiac surgical patients with pulmonary hypertension and left ventricular dysfunction. A prospective, randomized study. Tertiary care teaching hospital. The study included patients with valvular heart disease and pulmonary artery hypertension undergoing valve surgery. Forty patients were allocated randomly to receive either milrinone, 50 µg/kg bolus followed by infusion at a rate of 0.5 µg/kg/min (group 1), or levosimendan, 10 µg/kg bolus followed by infusion at a rate of 0.1 µg/kg/min (group 2) for 24 hours after surgery. Hemodynamic parameters were measured using a pulmonary artery catheter, and biventricular functions were assessed using echocardiography. Mean pulmonary artery pressures and the pulmonary vascular resistance index were comparable between the 2 groups at several time points in the intensive care unit. Biventricular function was comparable between both groups. Postcardiopulmonary bypass right ventricular systolic and diastolic functions decreased in both groups compared with baseline, whereas 6 hours postbypass left ventricular ejection fraction improved in patients with stenotic valvular lesions. Levosimendan use was associated with higher heart rate, increased cardiac index, decreased systemic vascular resistance index, and increased requirement of norepinephrine infusion compared with milrinone. The results of this study demonstrated that levosimendan was not clinically better than milrinone. Levosimendan therapy resulted in a greater increase in heart rate, decrease in systemic vascular resistance, and a greater need for norepinephrine than in patients who received milrinone. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. A left ventricular epicardial to right ventricular endocardial dominant frequency gradient exists in human ventricular fibrillation.

    PubMed

    Torres, Jose Luis; Shah, Bindi K; Greenberg, Richard M; Deger, Florin Titus; Gerstenfeld, Edward P

    2010-10-01

    We hypothesized that in patients with left ventricular dysfunction undergoing implant of a biventricular ICD, the local dominant frequency during early induced ventricular fibrillation would be higher at an epicardial left ventricular position compared to an endocardial right ventricular position. Patients undergoing implant of a biventricular ICD were studied. During ventricular fibrillation induction, bipolar electrograms were recorded from leads at an epicardial left ventricular position and an endocardial right ventricular position. Overlapping 2-s fast Fourier transforms were obtained for 6 s of ventricular fibrillation. The dominant frequency and organizational index were compared. Thirty-four patients (20 men, age 64 ± 11 years) underwent 57 inductions of ventricular fibrillation. Eighteen patients had non-ischemic dilated cardiomyopathy and 16 had ischemic dilated cardiomyopathy. The dominant frequency was higher at a lateral epicardial left ventricular position than an apical endocardial right ventricular position in 18 patients with non-ischemic dilated cardiomyopathy (LV epicardial 5.34 ± 0.37 Hz, RV endocardial 5.09 ± 0.41 Hz, p < 0.001), but not in 16 patients with ischemic dilated cardiomyopathy (LV epicardial 4.99 ± 0.57 Hz, RV epicardial 4.87 ± 0.65 Hz, p = 0.094). In patients with non-ischemic dilated cardiomyopathy, there is a dominant frequency gradient during early ventricular fibrillation induced at ICD testing from the lateral left ventricular epicardium to the apical right ventricular endocardium.

  4. An unsupervised approach for measuring myocardial perfusion in MR image sequences

    NASA Astrophysics Data System (ADS)

    Discher, Antoine; Rougon, Nicolas; Preteux, Francoise

    2005-08-01

    Quantitatively assessing myocardial perfusion is a key issue for the diagnosis, therapeutic planning and patient follow-up of cardio-vascular diseases. To this end, perfusion MRI (p-MRI) has emerged as a valuable clinical investigation tool thanks to its ability of dynamically imaging the first pass of a contrast bolus in the framework of stress/rest exams. However, reliable techniques for automatically computing regional first pass curves from 2D short-axis cardiac p-MRI sequences remain to be elaborated. We address this problem and develop an unsupervised four-step approach comprising: (i) a coarse spatio-temporal segmentation step, allowing to automatically detect a region of interest for the heart over the whole sequence, and to select a reference frame with maximal myocardium contrast; (ii) a model-based variational segmentation step of the reference frame, yielding a bi-ventricular partition of the heart into left ventricle, right ventricle and myocardium components; (iii) a respiratory/cardiac motion artifacts compensation step using a novel region-driven intensity-based non rigid registration technique, allowing to elastically propagate the reference bi-ventricular segmentation over the whole sequence; (iv) a measurement step, delivering first-pass curves over each region of a segmental model of the myocardium. The performance of this approach is assessed over a database of 15 normal and pathological subjects, and compared with perfusion measurements delivered by a MRI manufacturer software package based on manual delineations by a medical expert.

  5. Pacing for neurally mediated syncope: is placebo powerless?

    PubMed

    Brignole, M; Sutton, R

    2007-01-01

    After two recent controlled trials failed to prove superiority of cardiac pacing over placebo in patients affected by neurally mediated syncope, a widely accepted opinion is that cardiac pacing therapy is not very effective and that a strong placebo effect exists. To measure the effect of placebo pacing therapy. We compared the recurrence rate of syncope during placebo vs. no treatment in controlled trials of drug or pacing therapy. Syncope recurred in 38% of 252 patients randomized to placebo pooled from five trials vs. 34% of 881 patients randomized to no treatment pooled from eight trials. The corresponding recurrence rate with active cardiac pacing was 15% in 203 patients from six trials. Placebo is not an effective therapy for neurally mediated syncope. Different selection criteria in patients who are candidates for cardiac pacing-for example, presence, absence, or severity of the cardioinhibitory reflex may separate positive from negative trials.

  6. PACE (Revised). Resource Guide. Research & Development Series No. 240D.

    ERIC Educational Resources Information Center

    Ashmore, M. Catherine; Pritz, Sandra G.

    This resource guide contains information on the Program for Acquiring Competence in Entrepreneurship (PACE) materials, a glossary, and listings of sources of information. Introductory materials include a description of PACE, information on use of PACE materials, and objectives of the 18 units for all three levels at which they are developed. An…

  7. A Study of Instructional Methods Used in Fast-Paced Classes

    ERIC Educational Resources Information Center

    Lee, Seon-Young; Olszewski-Kubilius, Paula

    2006-01-01

    This study involved 15 secondary-level teachers who taught fast-paced classes at a university based summer program and similar regularly paced classes in their local schools in order to examine how teachers differentiate or modify instructional methods and content selections for fast-paced classes. Interviews were conducted with the teachers…

  8. Predicting Successful Completion Using Student Delay Indicators in Undergraduate Self-Paced Online Courses

    ERIC Educational Resources Information Center

    Lim, Janine M.

    2016-01-01

    Self-paced online courses meet flexibility and learning needs of many students, but skepticism persists regarding the quality and the tendency for students to procrastinate in self-paced courses. Research is needed to understand procrastination and delay patterns of students in online self-paced courses to predict successful completion and…

  9. Further evidence for the role of gap junctions in the delayed antiarrhythmic effect of cardiac pacing.

    PubMed

    Miskolczi, Gottfried; Gönczi, Márton; Kovács, Mária; Seprényi, György; Végh, Ágnes

    2015-07-01

    The objective of this study was to provide evidence that gap junctions are involved in the delayed antiarrhythmic effect of cardiac pacing. Twenty-four dogs were paced through the right ventricle (4 × 5 min, rate of 240 beats/min) 24 h prior to a 25 min occlusion of the left anterior descending coronary artery. Some of these paced dogs were infused with 50 (n = 7) or 100 μmol/L (n = 7) of the gap junction uncoupler carbenoxolone (CBX), prior to and during the occlusion. Ten sham-paced dogs, subjected only to occlusion, served as the controls. Cardiac pacing markedly reduced the number of ectopic beats and episodes of ventricular tachycardia (VT), as well the incidence of VT and ventricular fibrillation during occlusion. The changes in severity of ischaemia and tissue electrical resistance were also less marked compared with the unpaced controls. Pacing also preserved the permeability of gap junctions, the phosphorylation of connexin43, and the structural integrity of the intercalated discs. The closing of gap junctions with CBX prior to and during ischaemia markedly attenuated or even abolished these protective effects of pacing. Our results support the previous findings that gap junctions play a role in the delayed antiarrhythmic effect of cardiac pacing.

  10. Differential effects of film on preschool children's behaviour dependent on editing pace.

    PubMed

    Kostyrka-Allchorne, Katarzyna; Cooper, Nicholas R; Gossmann, Anna Maria; Barber, Katy J; Simpson, Andrew

    2017-05-01

    Evidence on how the pace of television and film editing affects children's behaviour and attention is inconclusive. We examined whether a fast-paced film affected how preschool-aged children interacted with toys. The study comprised 70 children (36 girls) aged two to four-and-a-half years who attended preschools in Essex, United Kingdom. The children were paired up and tested with either a fast- or a slow-paced film of a narrator reading a children's story. The fast-paced version had 102 camera cuts and 16 still images, and the slow-paced version had 22 camera cuts and four still images. Each dyad took part in two video-recorded free-play sessions, before and after they watched one of the specially edited four-minute films. The number of toys the children played with before and after the film sessions was recorded. Before they watched the films, the children's behaviour did not differ between the groups. However, after watching the film, the children in the fast-paced group shifted their attention between toys more frequently than the children who watched the slow-paced film. Even a brief exposure to differently paced films had an immediate effect on how the children interacted with their toys. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  11. Pacing and Self-regulation: Important Skills for Talent Development in Endurance Sports.

    PubMed

    Elferink-Gemser, Marije T; Hettinga, Florentina J

    2017-07-01

    Pacing has been characterized as a multifaceted goal-directed process of decision making in which athletes need to decide how and when to invest their energy during the race, a process essential for optimal performance. Both physiological and psychological characteristics associated with adequate pacing and performance are known to develop with age. Consequently, the multifaceted skill of pacing might be under construction throughout adolescence, as well. Therefore, the authors propose that the complex skill of pacing is a potential important performance characteristic for talented youth athletes that needs to be developed throughout adolescence. To explore whether pacing is a marker for talent and how talented athletes develop this skill in middle-distance and endurance sports, they aim to bring together literature on pacing and literature on talent development and self-regulation of learning. Subsequently, by applying the cyclical process of self-regulation to pacing, they propose a practical model for the development of performance in endurance sports in youth athletes. Not only is self-regulation essential throughout the process of reaching the long-term goal of athletic excellence, but it also seems crucial for the development of pacing skills within a race and the development of a refined performance template based on previous experiences. Coaches and trainers are advised to incorporate pacing as a performance characteristic in their talent-development programs by stimulating their athletes to reflect, plan, monitor, and evaluate their races on a regular basis to build performance templates and, as such, improve their performance.

  12. Interatrial septum pacing guided by three-dimensional intracardiac echocardiography.

    PubMed

    Szili-Torok, Tamas; Kimman, Geert Jan P; Scholten, Marcoen F; Ligthart, Jurgen; Bruining, Nico; Theuns, Dominic A M J; Klootwijk, Peter J; Roelandt, Jos R T C; Jordaens, Luc J

    2002-12-18

    Currently, the interatrial septum (IAS) pacing site is indirectly selected by fluoroscopy and P-wave analysis. The aim of the present study was to develop a novel approach for IAS pacing using intracardiac echocardiography (ICE). Interatrial septum pacing may be beneficial for the prevention of paroxysmal atrial fibrillation. Cross-sectional images are acquired during a pull-back of the ICE transducer from the superior vena cava into the inferior vena cava by an electrocardiogram- and respiration-gated technique. Both atria are then reconstructed using three-dimensional (3D) imaging. Using an "en face" view of the IAS, the desired pacing site is selected. Following lead placement and electrical testing, another 3D reconstruction is performed to verify the final lead position. Twelve patients were included in this study. The IAS pacing was achieved in all patients including six suprafossal (SF) and six infrafossal (IF) lead locations all confirmed by 3D imaging. The mean duration times of atrial lead implantation and fluoroscopy were 70 +/- 48.9 min and 23.7 +/- 20.6 min, respectively. The IAS pacing resulted in a significant reduction of the P-wave duration as compared to sinus rhythm (98.9 +/- 19.3 ms vs. 141.3 +/- 8.6 ms; p < 0.002). The SF pacing showed a greater reduction of the P-wave duration than IF pacing (59.4 +/- 6.6 ms vs. 30.2 +/- 13.6 ms; p < 0.004). Three-dimensional ICE is a feasible tool for guiding IAS pacing.

  13. PACE4 is an important driver of ZR-75-1 estrogen receptor-positive breast cancer proliferation and tumor progression.

    PubMed

    Panet, François; Couture, Frédéric; Kwiatkowska, Anna; Desjardins, Roxane; Guérin, Brigitte; Day, Robert

    2017-08-01

    Breast cancer is the most frequent and deadly malignancy in women worldwide. Despite national screening programs combined with new treatments relapse rate remain high and new therapies are needed. From previous work, we identified PACE4, a member of the proprotein convertase (PCs) family of endoproteases, as a novel therapeutic target in prostate cancer. In the present study we asked the question if PACE4 could also be a potential target in breast cancer. In clinical samples of breast adenocarcinoma, we observed a specific overexpression of PACE4 in the estrogen-receptor (ER) positive subtype. We therefore looked for a breast cancer cell line model which would be representative and thus focused on the ZR-75-1 since it both expresses PACE4 and is estrogen-receptor positive. We compared stable knockdowns of furin, PACE4 and PC7 in the estrogen-receptor-positive cell line ZR-75-1 to evaluate their respective contribution to cell growth and tumor progression. PACE4 was the only PC displaying an impact on cell growth. A PACE4 peptide-based inhibitor (C23) was tested and shown to decrease proliferation of ZR-75-1 cells in cell based assays. C23 also had potent effects of tumor progression in vivo on xenografts of the ZR-75-1 cell line in athymic nude mice. Thus, PACE4-silencing and systemic administration of a PACE4 inhibitor resulted in hindered tumor progression with reduction in proliferative indices and increased cell quiescence assessed with biomarkers. Our results suggest that PACE4 is a promising target for estrogen-receptor-positive breast cancer. Copyright © 2017 Elsevier GmbH. All rights reserved.

  14. Impact of high-grade Atrioventricular block and cumulative frequent pacing on atrial arrhythmias.

    PubMed

    Wali, Eisha; Deshmukh, Amrish; Bukari, Abdallah; Broman, Michael; Aziz, Zaid; Beaser, Andrew; Upadhyay, Gaurav; Nayak, Hemal M; Tung, Roderick; Ozcan, Cevher

    2018-06-21

    The relationship between high-grade AV block (HGAVB) with cumulative frequent pacing and risk of atrial arrhythmias (AAs) has not been well characterized. We hypothesized HGAVB and pacing may have significant impact on incidence and prevalence of AAs by modulating atrial substrate. To determine impact of HGAVB and pacing on AAs including atrial fibrillation (AF), atrial flutter (AFL), and atrial tachycardia (AT). All consecutive patients who underwent dual chamber pacemaker implantation for HGAVB from 2005 to 2011 at the University of Chicago were included. AAs and percent of pacing were detected through device interrogation. Patients' data were collected from electronic medical records and clinic visits. A total of 166 patients (mean age 71±15 years; 54% female, 56% African-American) were studied. AF was documented in 27% of patients before pacemaker implantation. During a mean 5.8±2.2 years of follow-up, 47% had device-detected AF, 10% AFL and 26% AT. New-onset AF was documented in 40 of the 122 patients without prior AF (33%). Continuous (≥99%) right ventricular pacing was associated with significantly decreased AF prevalence (34% versus 59%, p = 0.005), and correlated with lower incidence (26% versus 41%, p = 0.22). Pacing suppressed AF in 14% of patients with baseline AF; those patients had lower atrial pacing (3.2% versus 45%, p < 0.0001). Left atrial dilation was the only independent predictor of AF with frequent pacing (p = 0.009). HGAVB is associated with high incidence and prevalence of AAs with and without pacing. Cumulative frequent (≥99%) ventricular pacing reduces risk of AF in patients with HGAVB. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Prevalence of conduction delay of the right atrium in patients with SSS: implications for pacing site selection.

    PubMed

    Verlato, Roberto; Zanon, Francesco; Bertaglia, Emanuele; Turrini, Pietro; Baccillieri, Maria Stella; Baracca, Enrico; Bongiorni, Maria Grazia; Zampiero, Aldo; Zonzin, Pietro; Pascotto, Pietro; Venturini, Diego; Corbucci, Giorgio

    2007-09-01

    To evaluate the prevalence of severe right atrial conduction delay in patients with sinus node dysfunction (SND) and atrial fibrillation (AF) and the effects of pacing in the right atrial appendage (RAA) and in the inter-atrial septum (IAS). Forty-two patients (15 male, 72 +/- 7 years) underwent electrophysiologic study to measure the difference between the conduction time from RAA to coronary sinus ostium during stimulation at 600 ms and after extrastimulus (DeltaCTos). Patients were classified as group A if DeltaCTos > 60 ms and group B if < 60 ms. Each Group was randomized to RAA/IAS pacing and algorithms ON/OFF. Fifteen patients (36%, group A) had DeltaCTos = 76 +/- 11 ms and 27 patients (64%, group B) had DeltaCTos = 36 +/- 20 ms. Twenty-two patients were paced at the RAA and 20 at the IAS. During the study, no AF recurrences were reported in 11 of 42 (26%) patients, independently of RAA or IAS pacing. Patients from group A and RAA pacing had 0.79 +/- 0.81 episodes of AF/day during DDD, which increased to 1.52 +/- 1.41 episodes of AF/day during DDDR + Alg (P = 0.046). Those with IAS pacing had 0.5 +/- 0.24 episodes of AF/day during DDD, which decreased to 0.06 +/- 0.08 episodes of AF/day during DDDR + Alg (P = 0.06). In group B, no differences were reported between pacing sites and pacing modes. Severe right atrial conduction delay is present in one-third of patients with SND and AF: continuous pacing at the IAS is superior to RAA for AF recurrences. In patients without severe conduction delay, no differences between pacing site or mode were observed.

  16. Abnormal biventricular performance in asymptomatic adolescents late after repaired Tetralogy of Fallot: Combined two-dimensional speckle tracking and three-dimensional echocardiography study.

    PubMed

    Weng, Ken-Pen; Hung, Yu-Chi; Huang, Shih-Hui; Wu, Huang-Wei; Chien, Kuang-Jen; Lin, Chu-Chuan; Peng, Hsu-Hsia; Wu, Ming-Ting

    2018-02-01

    The aim of this prospective study was to assess biventricular performance in asymptomatic adolescents with repaired tetralogy of Fallot (TOF) using 2D speckle tracking and real time 3D echocardiography simultaneously. We studied 31 patients with repaired TOF (M/F: 22/9, age: 16.1 ± 6.1 yrs) who had history of cardiac surgery with mean follow-up duration of 12.8 years, and 32 age- and sex-matched normal individuals (M/F: 23/9, age: 16.6 ± 5.1 yrs). All subjects underwent speckle tracking and 3D echocardiography, electrocardiogram, treadmill, and blood sampling for measurement of brain natriuretic peptide (BNP). Compared to the control group, the TOF group had higher BNP level (31.8 ± 21.4 vs 14.1 ± 12.4 pg/ml, p < 0.01), lower peak oxygen consumption (8.4 ± 1.7 vs 9.9 ± 1.6 ml/kg/min, p < 0.05), and longer QRS duration (126 ± 30 vs 82 ± 9 ms, p < 0.01). Patients with repaired TOF had significantly impaired right ventricle (RV) global and all six regional longitudinal strain and strain rate than normal controls. Left ventricle (LV) global and mainly apical regional longitudinal strain and strain rate were reduced in patients with repaired TOF. There was a significant correlation of global longitudinal strain (r = 0.456, p = 0.01) and global time to peak longitudinal strain (r = 0.484, p < 0.01) between LV and RV in patients with repaired TOF. In terms of 3D echo cardiographic volume data, patients with repaired TOF had lower LV stroke volume index (p < 0.05), but higher RV end diastolic volume index (p < 0.01), RV end systolic volume index (p < 0.01), RV stroke volume index (p < 0.01), and pulmonary regurgitation fraction (p < 0.01) than normal controls. Our results suggest asymptomatic adolescents with repaired TOF had abnormal biventricular myocardial performance, as demonstrated by combined 2D speckle-tracking and 3D echocardiography. The implications of these findings for management of adolescents late after repaired TOF remain to be determined. Copyright © 2017. Published by Elsevier Taiwan LLC.

  17. The Syncardia™ total artificial heart: in vivo, in vitro, and computational modeling studies

    PubMed Central

    Slepian, Marvin J.; Alemu, Yared; Soares, João Silva; Smith, Richard G.; Einav, Shmuel; Bluestein, Danny

    2014-01-01

    The SynCardia™ total artificial heart (TAH) is the only FDA-approved TAH in the world. The SynCardia™ TAH is a pneumatically driven, pulsatile system capable of flows of >9 L/min. The TAH is indicated for use as a bridge to transplantation (BTT) in patients at imminent risk of death from non-reversible bi-ventricular failure. In the Pivotal US approval trial the TAH achieved a BTT rate of >79%. Recently a multi-center, post-market approval study similarly demonstrated a comparable BTT rate. A major milestone was recently achieved for the TAH, with over 1100 TAHs having been implanted to date, with the bulk of implantation occurring at an ever increasing rate in the past few years. The TAH is most commonly utilized to save the lives of patients dying from end-stage bi-ventricular heart failure associated with ischemic or non-ischemic dilated cardiomyopathy. Beyond progressive chronic heart failure, the TAH has demonstrated great efficacy in supporting patients with acute irreversible heart failure associated with massive acute myocardial infarction. In recent years several diverse clinical scenarios have also proven to be well served by the TAH including severe heart failure associated with advanced congenital heart disease. failed or burned-out transplants, infiltrative and restrictive cardiomyopathies and failed ventricular assist devices. Looking to the future a major unmet need remains in providing total heart support for children and small adults. As such, the present TAH design must be scaled to fit the smaller patient, while providing equivalent, if not superior flow characteristics, shear profiles and overall device thrombogenicity. To aid in the development of a new “pediatric,” TAH an engineering methodology known as “Device Thrombogenicity Emulation (DTE)”, that we have recently developed and described, is being employed. Recently, to further our engineering understanding of the TAH, as steps towards next generation designs we have: (1) assessed of the degree of platelet reactivity induced by the present clinical 70 cc TAH using a closed loop platelet activity state assay, (2) modeled the motion of the TAH pulsatile mobile diaphragm, and (3) performed fluid-structure interactions and assessment of the flow behavior through inflow and outflow regions of the TAH fitted with modern bi-leaflet heart valves. Developing a range of TAH devices will afford biventricular replacement therapy to a wide range of patients, for both short and long-term therapy. PMID:23305813

  18. First clinical use of a bioprosthetic total artificial heart: report of two cases.

    PubMed

    Carpentier, Alain; Latrémouille, Christian; Cholley, Bernard; Smadja, David M; Roussel, Jean-Christian; Boissier, Elodie; Trochu, Jean-Noël; Gueffet, Jean-Pierre; Treillot, Michèle; Bizouarn, Philippe; Méléard, Denis; Boughenou, Marie-Fazia; Ponzio, Olivier; Grimmé, Marc; Capel, Antoine; Jansen, Piet; Hagège, Albert; Desnos, Michel; Fabiani, Jean-Noël; Duveau, Daniel

    2015-10-17

    The development of artificial hearts in patients with end-stage heart disease have been confronted with the major issues of thromboembolism or haemorrhage. Since valvular bioprostheses are associated with a low incidence of these complications, we decided to use bioprosthetic materials in the construction of a novel artificial heart (C-TAH). We report here the device characteristics and its first clinical applications in two patients with end-stage dilated cardiomyopathy. The aim of the study was to evaluate safety and feasibility of the CARMAT TAH for patients at imminent risk of death from biventricular heart failure and not eligible for transplant. The C-TAH is an implantable electro-hydraulically actuated pulsatile biventricular pump. All components, batteries excepted, are embodied in a single device positioned in the pericardial sac after excision of the native ventricles. We selected patients admitted to hospital who were at imminent risk of death, having irreversible biventricular failure, and not eligible for heart transplantation, from three cardiac surgery centres in France. The C-TAH was implanted in two male patients. Patient 1, aged 76 years, had the C-TAH implantation on Dec 18, 2013; patient 2, aged 68 years, had the implantation on Aug 5, 2014. The cardiopulmonary bypass times for C-TAH implantation were 170 min for patient 1 and 157 min for patient 2. Both patients were extubated within the first 12 postoperative hours and had a rapid recovery of their respiratory and circulatory functions as well as a normal mental status. Patient 1 presented with a tamponade on day 23 requiring re-intervention. Postoperative bleeding disorders prompted anticoagulant discontinuation. The C-TAH functioned well with a cardiac output of 4·8-5·8 L/min. On day 74, the patient died due to a device failure. Autopsy did not detect any relevant thrombus formation within the bioprosthesis nor the different organs, despite a 50-day anticoagulant-free period. Patient 2 experienced a transient period of renal failure and a pericardial effusion requiring drainage, but otherwise uneventful postoperative course. He was discharged from the hospital on day 150 after surgery with a wearable system without technical assistance. After 4 months at home, the patient suffered low cardiac output. A change of C-TAH was attempted but the patient died of multiorgan failure. This preliminary experience could represent an important contribution to the development of total artificial hearts using bioprosthetic materials. CARMAT SA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Pacing, Pixels, and Paper: Flexibility in Learning Words from Flashcards

    ERIC Educational Resources Information Center

    Sage, Kara; Rausch, Joseph; Quirk, Abigail; Halladay, Lauren

    2016-01-01

    The present study focused on how self-control over pace might help learners successfully extract information from digital learning aids. Past research has indicated that too much control over pace can be overwhelming, but too little control over pace can be ineffective. Within the popular self-testing domain of flashcards, we sought to elucidate…

  20. Effects of Modality and Pace on Achievement, Mental Effort, and Positive Affect in Multimedia Learning Environments

    ERIC Educational Resources Information Center

    Izmirli, Serkan; Kurt, Adile Askim

    2016-01-01

    The purpose of the study was to examine the effects of instruction given with different multimedia modalities (written text + animation or narration + animation) on the academic achievement, cognitive load, and positive affect in different paces (learner-paced or system-paced); 97 freshmen university students divided into four groups taught in…

  1. The effects of husbandry training on stereotypic pacing in captive African wild dogs (Lycaon pictus).

    PubMed

    Shyne, Amanda; Block, Martin

    2010-01-01

    To examine the effects of operant conditioning on stereotypic pacing in 3 female African wild dogs located at the Franklin Park Zoo in Boston, this study made recordings of pacing behavior immediately following individual sessions of husbandry training and 2 no-training conditions. The study found significant differences in the percentage of observations spent in stereotypic pacing behaviors for all 3 dogs among the 3 different conditions. The authors discuss the data in terms of the contribution of motivated tasks to the effects and the role of food deprivation in the expression of stereotypic pacing. The study suggests that even short periods of training may improve the African wild dogs' welfare by reducing stereotypic pacing following the conditioning sessions.

  2. Rate-dependent Loss of Capture during Ventricular Pacing.

    PubMed

    Wang, Jingfeng; Chen, Haiyan; Su, Yangang; Ge, Junbo

    2015-01-01

    A 63-year-old patient who had undergone atrial septal defect surgical repair received implantation of a single chamber VVI pacemaker for long RR intervals during atrial fibrillation. One week later, an intermittent loss of capture and sensing failure was detected at a pacing rate of 70 beats/min. However, a successful capture was observed during rapid pacing. Consequently, the pacing rate was temporarily adjusted to 90 beats/min. At the 3-month follow-up, the pacemaker was shown to be functioning properly independent of the pacing rate. An echocardiogram showed that the increased pacing rates were accompanied by a reduction in the right ventricular outflow tract dimension. The pacemaker was then permanently programmed at a lower rate of 60 beats/min.

  3. Risk Stratification of Future Left Ventricular Dysfunction for Patients with Indications for Right Ventricular Pacing due to Bradycardia.

    PubMed

    Ooka, Junichi; Tanaka, Hidekazu; Hatani, Yutaka; Hatazawa, Keiko; Matsuzoe, Hiroki; Shimoura, Hiroyuki; Sano, Hiroyuki; Sawa, Takuma; Motoji, Yoshiki; Mochizuki, Yasuhide; Ryo-Koriyama, Keiko; Matsumoto, Kensuke; Fukuzawa, Koji; Hirata, Ken-Ichi

    2017-10-21

    Although right ventricular (RV) pacing is the only effective treatment for patients with symptomatic bradycardia, it creates left ventricular (LV) dyssynchrony, which can induce LV dysfunction and heart failure. The current criterion for consideration of cardiac resynchronization therapy (CRT) is LV ejection fraction (LVEF) ≤ 35%, but indication for CRT in patients required for RV pacing with LVEF > 35% remains unclear.We studied 40 patients, all LVEF ≥ 35%, who had undergone implantable cardioverter-defibrillator implantation with RV pacing < 5%. Echocardiography was performed at baseline and during RV pacing. LV dyssynchrony was defined as anteroseptal-to-posterior wall delay from the mid-LV short-axis view using two-dimensional speckle-tracking radial strain (significant: ≥ 130 ms). Patients were divided into two groups based on baseline LVEF: normal LVEF ( ≥ 50%; n = 20) and mildly reduced LVEF (35-50%; n = 20).LVEF and LV dyssynchrony in patients with mildly reduced LVEF deteriorated significantly during RV pacing compared to those in patients with normal LVEF. Moreover, changes in LV dyssynchrony during RV pacing significantly correlated with changes in LVEF (r = -0.44, P < 0.01). Multivariate logistic regression analysis showed that baseline LVEF was the only independent predictor and baseline LVEF < 48% predictive of significant LV dyssynchrony during RV pacing.The extent of RV pacing-induced LV dysfunction may be associated with baseline LV function. These adverse effects on patients with mildly reduced LVEF of 35-50% and indications for RV pacing due to bradycardia can thus be prevented by CRT.

  4. Catheter Ablation of Focal Atrial Tachycardia Using Remote Magnetic Navigation.

    PubMed

    Webster, Mark; Pasupati, Sanjeevan; Lever, Nigel; Stiles, Martin

    2018-05-01

    This first-in-human study evaluated the safety and technical feasibility of the Tempo temporary cardiac pacing lead (BioTrace Medical), which includes a novel fixation mechanism and soft tip. Complications of temporary pacing leads include dislodgment, arrhythmias, and ventricular perforation. Temporary pacing applications have increased with transcatheter aortic valve replacement (TAVR) growth, for rapid pacing during balloon valvuloplasty (BAV) and valve deployment, and for periprocedural bradyarrhythmia support. Eligible patients required temporary pacing for TAVR, BAV, or electrophysiology (EP) procedures. Transthoracic echocardiograms were obtained at baseline and 24 hours after lead removal. Safety was defined as freedom from pericardial effusion requiring intervention or evidence of tamponade. Technical feasibility involved successful intracardiac delivery and pace capture. Additional evaluations included pacing threshold (PCT), rapid pacing, dislodgment, or sustained ventricular arrhythmias. Follow-up was to 30 days. Twenty-five patients (60% female; mean age, 64 ± 19 years) underwent 13 TAVRs (7 Sapien 3 valves [Edwards Lifesciences], 4 CoreValves [Medtronic], and 2 Lotus valves [Boston Scientific]), 11 EP procedures, and 1 BAV at two New Zealand centers from January 2016 to June 2016. Safety was met in all patients, with no device-related adverse events. Technical feasibility was achieved in 23 cases (92%); 2 patients had unsuitable anatomy. No patient had lead dislodgment or sustained ventricular arrhythmias, and the final procedural PCT was 0.7 ± 0.5 mA. Rapid pacing was successful in all cases. Five patients had successful postprocedural use up to 5 days. This first-in-human study demonstrates the safety and technical feasibility of the Tempo lead, providing stable periprocedural temporary pacing support.

  5. Pacing: a concept analysis of the chronic pain intervention.

    PubMed

    Jamieson-Lega, Kathryn; Berry, Robyn; Brown, Cary A

    2013-01-01

    The intervention of pacing is regularly recommended for chronic pain patients. However, pacing is poorly defined and appears to be interpreted in varying, potentially contradictory manners within the field of chronic pain. This conceptual lack of clarity has implications for effective service delivery and for researchers' ability to conduct rigorous study. An examination of the background literature demonstrates that while pacing is often one part of a multidisciplinary pain management program, outcome research is hindered by a lack of a clear and shared definition of this currently ill-defined construct. To conduct a formal concept analysis of the term 'pacing'. A standardized concept analysis process (including literature scoping to identify all uses of the concept, analysis to determine defining attributes of the concept and identification of model, borderline and contrary cases) was used to determine what the concept of pacing does and does not represent within the current evidence base. A conceptual model including the core attributes of action, time, balance, learning and self-management emerged. From these attributes, an evidence-based definition for pacing was composed and distributed to stakeholders for review. After consideration of stakeholder feedback, the emergent definition of pacing was finalized as follows: "Pacing is an active self-management strategy whereby individuals learn to balance time spent on activity and rest for the purpose of achieving increased function and participation in meaningful activities". The findings of the present concept analysis will help to standardize the use and definition of the term pacing across disciplines for the purposes of both pain management and research.

  6. A Closer Look at Split Visual Attention in System- and Self-Paced Instruction in Multimedia Learning

    ERIC Educational Resources Information Center

    Schmidt-Weigand, Florian; Kohnert, Alfred; Glowalla, Ulrich

    2010-01-01

    Two experiments examined visual attention distribution in learning from text and pictures. Participants watched a 16-step multimedia instruction on the formation of lightning. In Experiment 1 (N=90) the instruction was system-paced (fast, medium, slow pace), while it was self-paced in Experiment 2 (N=31). In both experiments the text modality was…

  7. Helping Girls Get Back on Track: An Implementation Study of the PACE Center for Girls

    ERIC Educational Resources Information Center

    Treskon, Louisa; Millenky, Megan; Freedman, Lily

    2017-01-01

    PACE Center for Girls is a unique program that provides academic and social services to girls ages 11 to 18. Girls eligible for PACE exhibit multiple health, safety, and delinquency risk factors, such as poor academic performance, exposure to abuse or violence, truancy, risky sexual behavior, and substance abuse. PACE seeks to help them onto a…

  8. What Pace Is Best? Assessing Adults' Learning from Slideshows and Video

    ERIC Educational Resources Information Center

    Sage, Kara

    2014-01-01

    When acquiring information from a 2D platform, self-control and/or optimal pacing may help reduce cognitive load and enhance learning outcomes. In the present research, adults viewed novel action sequences via one of four learning media: (1) self-paced slideshows, where viewers advanced through slides at their own pace by clicking a mouse, (2)…

  9. 77 FR 28900 - Amended Certification Regarding Eligibility to Apply for Worker Adjustment Assistance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-16

    ... Enterprises, Inc., Fitzgerald, Georgia TA-W-81,004C Pace American Enterprises, Inc., Lebanon, Oregon TA-W-81... Enterprises, Inc., Lebanon, Oregon (TA-W- 81,004C); and Pace American Enterprises, Inc., Hurricane, Utah (TA-W...., Fitzgerald, Georgia (TA-W-81,004B), Pace American Enterprises, Inc., Lebanon, Oregon (TA-W-81,004C), Pace...

  10. The Manipulation of Pace within Endurance Sport

    PubMed Central

    Skorski, Sabrina; Abbiss, Chris R.

    2017-01-01

    In any athletic event, the ability to appropriately distribute energy is essential to prevent premature fatigue prior to the completion of the event. In sport science literature this is termed “pacing.” Within the past decade, research aiming to better understand the underlying mechanisms influencing the selection of an athlete's pacing during exercise has dramatically increased. It is suggested that pacing is a combination of anticipation, knowledge of the end-point, prior experience and sensory feedback. In order to better understand the role each of these factors have in the regulation of pace, studies have often manipulated various conditions known to influence performance such as the feedback provided to participants, the starting strategy or environmental conditions. As with all research there are several factors that should be considered in the interpretation of results from these studies. Thus, this review aims at discussing the pacing literature examining the manipulation of: (i) energy expenditure and pacing strategies, (ii) kinematics or biomechanics, (iii) exercise environment, and (iv) fatigue development. PMID:28289392

  11. Forms of work organization and associations with shoulder disorders: Results from a French working population.

    PubMed

    Bodin, Julie; Garlantézec, Ronan; Costet, Nathalie; Descatha, Alexis; Fouquet, Natacha; Caroly, Sandrine; Roquelaure, Yves

    2017-03-01

    The aim of this study was to identify forms of work organization in a French region and to study associations with the occurrence of symptomatic and clinically diagnosed shoulder disorders in workers. Workers were randomly included in this cross-sectional study from 2002 to 2005. Sixteen organizational variables were assessed by a self-administered questionnaire: i.e. shift work, job rotation, repetitiveness of tasks, paced work/automatic rate, work pace dependent on quantified targets, permanent controls or surveillance, colleagues' work and customer demand, and eight variables measuring decision latitude. Five forms of work organization were identified using hierarchical cluster analysis (HCA) of variables and HCA of workers: low decision latitude with pace constraints, medium decision latitude with pace constraints, low decision latitude with low pace constraints, high decision latitude with pace constraints and high decision latitude with low pace constraints. There were significant associations between forms of work organization and symptomatic and clinically-diagnosed shoulder disorders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. 42 CFR 460.162 - Voluntary disenrollment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Enrollment and Disenrollment § 460.162 Voluntary disenrollment. A PACE...

  13. 42 CFR 460.162 - Voluntary disenrollment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Enrollment and Disenrollment § 460.162 Voluntary disenrollment. A PACE...

  14. Perioperative Care of the Patient With the Total Artificial Heart.

    PubMed

    Yaung, Jill; Arabia, Francisco A; Nurok, Michael

    2017-05-01

    Advanced heart failure continues to be a leading cause of morbidity and mortality despite improvements in pharmacologic therapy. High demand for cardiac transplantation and shortage of donor organs have led to an increase in the utilization of mechanical circulatory support devices. The total artificial heart is an effective biventricular assist device that may be used as a bridge to transplant and that is being studied for destination therapy. This review discusses the history, indications, and perioperative management of the total artificial heart with emphasis on the postoperative concerns.

  15. [Clinical development of the automatic implantable defibrillator over 35 years: A success story].

    PubMed

    Steinbeck, G

    2015-06-01

    After 12 years of development and experimental evaluation, the first automatic implantable cardioverter-defibrillator (ICD) was implanted in man on February 4, 1980. This overview describes the technical and functional developments over 35 years from a simple shock-box, weighing 292 g, to the sophisticated 80 g device of today, delivering graded therapy to sustained ventricular arrhythmias and biventricular stimulation to treat heart failure. Finally, a special tribute is given to Michel Mirowski, one of the inventors of the ICD, as scientist and physician dedicated to patient care.

  16. Transferring PACE Assessments Upon Home Sale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    National Renewable Energy Laboratory; Coughlin, Jason; Fuller, Merrian

    A significant barrier to investing in renewable energy and comprehensive energy efficiency improvements to homes across the country is the initial capital cost. Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing this upfront cost issue. Recently, the White House cited PACE programs as an important element of its 'Recovery through Retrofit' plan. The residential PACE model involves the creation of a special clean energy financing district that homeowners elect to opt into. Once opted in, the local government (usually at the city or county level) finances the upfrontmore » investment of the renewable energy installation and/or energy efficiency improvements. A special lien is attached to the property and the assessment is paid back as a line item on the property tax bill. As of April 2010, 17 states have passed legislation to allow their local governments to create PACE programs, two already have the authority to set up PACE programs, and over 10 additional states are actively developing enabling legislation. This policy brief analyzes one of the advantages of PACE, which is the transferability of the special assessment from one homeowner to the next when the home is sold. This analysis focuses on the potential for the outstanding lien to impact the sales negotiation process, rather than the legal nature of the lien transfer itself. The goal of this paper is to consider what implications a PACE lien may have on the home sales negotiation process so that it can be addressed upfront rather than risk a future backlash to PACE programs. If PACE programs do expand at a rapid rate, the chances are high that there will be other cases where prospective buyers uses PACE liens to negotiate lower home prices or require repayment of the lien as a condition of sale. As a result, PACE programs should highlight this issue as a potential risk factor for the sake of full disclosure. A good example of this is in Boulder County where the following statement is included in the ClimateSmart PACE program materials: 'Please Note: There is no legal requirement that the loan be paid off when you refinance or sell your home. However, this may be an item subject to negotiation with a future buyer and may also be a matter of negotiation with the mortgage lender.' Such candid disclosure for what might be a low risk event can be debated. However, a selling point of PACE programs is the transferability of the lien to the new homeowner. To the degree this benefit is questioned, PACE programs may end up looking more like home equity loan financing, with the associated debt repaid at closing, rather than property-based financing that remains with the improved home. While it is possible that upfront disclosure might negatively impact participation rates in PACE programs, it also will protect the integrity of a PACE program in later years if such situations come to pass. Ideally, this will become less of an issue over time as more homebuyers understand the positive economic and societal benefits of owning a home with clean energy features.« less

  17. [Management of surgery patients with implanted cardiac pacemakers].

    PubMed

    Ugljen, R; Dadić, D; Ferek-Petrić, B; Jelić, I; Letica, D; Anić, D; Husar, J

    1995-01-01

    Patients having cardiac pacemaker implanted may be subjected to various general surgery procedures. Application of electrosurgery for the purpose of resection and coagulation, provides a high frequency electric field which produces electric voltage on the electrodes of the pacing system. This voltage may be detected within the pacing system, and various arrhythmias can be provoked in correlation with underlying rhythm and mode of pacing. Preoperative patient control and proper pacemaker programming can prevent the pacing malfunctions due to the electrosurgery application. Appropriate positioning of the neutral electrode in relation to the pacing system avoids the electric fields intersection and decreases their interference.

  18. Enact legislation supporting residential property assessed clean energy financing (PACE)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saha, Devashree

    Congress should enact legislation that supports residential property assessed clean energy (PACE) programs in the nation’s states and metropolitan areas. Such legislation should require the Federal Housing Finance Agency (FHFA) to allow Fannie Mae and Freddie Mac to purchase residential mortgages with PACE assessments while at the same time providing responsible underwriting standards and a set of benchmarks for residential PACE assessments in order to minimize financial risks to mortgage holders. Congressional support of residential PACE financing will improve energy efficiency, encourage job creation, and foster economic growth in the nation’s state and metropolitan areas.

  19. Bachmann bundle pacing reduces atrial electromechanical delay in type 1 myotonic dystrophy patients.

    PubMed

    Russo, Vincenzo; Rago, Anna; Papa, Andrea Antonio; Arena, Giulia; Politano, Luisa; Nigro, Gerardo

    2018-04-01

    Atrial electromechanical delay (AEMD) is an echocardiographic parameter correlated with the onset of supraventricular arrhythmias in several clinical conditions. Inter-atrial septal pacing in the region of Bachmann's bundle (BB) has been shown to be safe and feasible in myotonic dystrophy type 1 (DM1) patients, with a low rate of sensing and pacing defects. The aim of this study was to assess the impact of temporary BB pacing compared with right atrial appendage (RAA) pacing on AEMD in DM1 patients undergoing pacemaker (PM) implantation for cardiac rhythm abnormalities. The study enrolled 70 consecutive DM1 patients undergoing PM implantation for cardiac rhythm abnormalities in accordance with the current guidelines. Seventy age- and sex-matched non-DM1 patients undergoing dual-chamber PM implantation for cardiac rhythm abnormalities were used as controls. The atrial pacing lead was temporarily positioned in the RAA and on the right side of the inter-atrial septum in the region of Bachmann's bundle. For each site (BB and RAA), temporary atrial pacing in the AAI mode was established at 10 beats per minute above the sinus rate and a detailed trans-thoracic echocardiogram with tissue Doppler (TDI) analysis was recorded after at least 10 min of atrial pacing to evaluate AEMD. Temporary RAA pacing did not show statistically significant differences in inter-AEMD (48.2 ± 17.8 vs 50.5 ± 16.5 ms; P = 0.8), intra-left AEMD (43.3 ± 15.5 vs 44.6 ± 15.8 ms; P = 0.1), or intra-right-AEMD (14.1 ± 4.2 vs 15.4 ± 5.8 ms; P = 0.9), in comparison with sinus rhythm. Temporary BB pacing determined a significantly lower inter-AEMD (36.1 ± 17.1 vs 50.5 ± 16.5 ms; P = 0.001) and intra-left AEMD (32.5 ± 15.2 vs 44.6 ± 15.8 ms; P = 0.001) values in comparison with temporary RAA pacing. No statistically significant difference was found in intra-right AEMD (12.2 ± 4.6 vs 15.4 ± 5.8 ms; P = 0.2). In the control group, neither temporary RAA pacing nor temporary BB pacing showed statistically significant differences in inter-AEMD, intra-left AEMD, or intra-right AEMD values in comparison with sinus rhythm. In DM1 patients undergoing dual-chamber PM implantation, atrial pacing in the Bachmann bundle region is associated with significantly lower echocardiographic indices of atrial electromechanical delay (inter-AEMD and intra-left AEMD) in comparison with RAA pacing.

  20. 42 CFR 460.12 - Application requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.12 Application requirements. (a...

  1. 42 CFR 460.104 - Participant assessment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Services § 460.104 Participant assessment. (a) Initial comprehensive assessment—(1...

  2. 42 CFR 460.12 - Application requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.12 Application requirements. (a...

  3. The effect of aging on pacing strategies of cross-country skiers and the role of performance level.

    PubMed

    Nikolaidis, Pantelis Theodoros; Villiger, Elias; Rosemann, Thomas; Knechtle, Beat

    2018-01-01

    The participation of master cross-country (XC) skiers in training and competition has increased during the last decades; however, little is known yet about whether these athletes differ from their younger counterparts in aspects of performance such as pacing. Therefore, the aim of the present study was to examine the combined effect of age and performance (race time) on pacing in cross-country (XC) skiing. We analyzed all finishers ( n  = 79,722) in 'Vasaloppet' from 2012 to 2017, the largest cross-country skiing race in the world, classified according to their race time into 10 groups: 3-4 h, 4-5 h, ..., 12-13 h. A trivial main effect of sex on total pace range was observed ( p  < 0.001, η 2  = 0.002), where women (44.1 ± 10.2%) had larger total pace range than men (40.9 ± 11.8%). A large main effect of performance group on total pace range was shown ( p  < 0.001, η 2  = 0.160), where the smallest total pace range was 21.8 ± 1.9% (3-4 h group) and the largest 50.1 ± 9.9% (10-11 h group). A trivial sex×performance group interaction on total pace range was found ( p  < 0.001, η 2  = 0.001) with the largest sex difference in pacing shown in 9-10 h group. A trivial and small main effect of age was found in women ( p  < 0.001, η 2  = 0.005) and men ( p  < 0.001, η 2  = 0.011), respectively, where the masters had smaller total pace range than their younger counterparts. A trivial age group×performance group interaction on total pace range was observed in both women ( p  < 0.001, η 2  = 0.008) and men ( p  < 0.001, η 2  = 0.006) with smaller differences among age groups in the faster performance groups. In summary, master XC skiers adopted a relatively even pacing independently from their race time and the differences in pacing from the younger XC skiers were more pronounced in the slower masters. These findings suggest that exercise attenuates the decline of performance in master XC skiers as shown by the similar pacing strategies between fast master XC skiers and their younger counterparts.

  4. 42 CFR 460.172 - Documentation of disenrollment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Enrollment and Disenrollment § 460.172 Documentation of disenrollment. A PACE...

  5. Helping Girls Get Back on Track: An Implementation Study of the PACE Center for Girls. Executive Summary

    ERIC Educational Resources Information Center

    Treskon, Louisa; Millenky, Megan; Freedman, Lily

    2017-01-01

    PACE Center for Girls is a unique program that provides academic and social services to girls ages 11 to 18. Girls eligible for PACE exhibit multiple health, safety, and delinquency risk factors, such as poor academic performance, exposure to abuse or violence, truancy, risky sexual behavior, and substance abuse. PACE seeks to help them onto a…

  6. Assessing the PACE of California residential solar deployment: Impacts of Property Assessed Clean Energy programs on residential solar photovoltaic deployment in California, 2010-2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deason, Jeff; Murphy, Sean

    A new study by Berkeley Lab found that residential Property Assessed Clean Energy (R-PACE) programs increased deployment of residential solar photovoltaic (PV) systems in California, raising it by about 7-12% in cities that adopt these programs. R-PACE is a financing mechanism that uses a voluntary property tax assessment, paid off over time, to facilitate energy improvements and, in some jurisdictions, water and resilience measures. While previous studies demonstrated that early, regional R-PACE programs increased solar PV deployment, this new analysis is the first to demonstrate these impacts from the large, statewide R-PACE programs dominating the California market today, which usemore » private capital to fund the upfront costs of the improvements. Berkeley Lab estimated the impacts using econometric techniques on two samples: -Large cities only, allowing annual demographic and economic data as control variables -All California cities, without these annual data Analysis of both samples controls for several factors other than R-PACE that would be expected to drive solar PV deployment. We infer that on average, cities with R-PACE programs were associated with greater solar PV deployment in our study period (2010-2015). In the large cities sample, solar PV deployment in jurisdictions with R-PACE programs was higher by 1.1 watts per owner-occupied household per month, or 12%. Across all cities, solar PV deployment in jurisdictions with R-PACE programs was higher by 0.6 watts per owner-occupied household per month, or 7%. The large cities results are statistically significant at conventional levels; the all-cities results are not. The estimates imply that the majority of solar PV deployment financed by R-PACE programs would likely not have occurred in their absence. Results suggest that R-PACE programs have increased PV deployment in California even in relatively recent years, as R-PACE programs have grown in market share and as alternate approaches for financing solar PV have developed. The U.S. Department of Energy’s Building Technologies Office supported this research.« less

  7. Dynamic and dual-site atrial pacing in the prevention of atrial fibrillation: The STimolazione Atrial DInamica Multisito (STADIM) Study.

    PubMed

    De Simone, Antonio; Senatore, Gaetano; Donnici, Giovanni; Turco, Pietro; Romano, Enrico; Gazzola, Carlo; Stabile, G

    2007-01-01

    The impact of new algorithms to consistently pace the atrium on the prevention of atrial fibrillation (AF) remains unclear. Our randomized, crossover study compared the efficacy of single- and dual-site atrial pacing, with versus without dynamic atrial overdrive pacing in preventing AF. We studied 72 patients (mean age = 69.6 +/- 6.5 years, 34 men) with sick sinus syndrome (SSS) and paroxysmal or persistent AF, who received dual-chamber pacemakers (PM) equipped with an AF prevention algorithm and two atrial leads placed in the right atrial appendage (RAA), by passive fixation, and in the coronary sinus ostium (CS), by active fixation, respectively. At implant, the patients were randomly assigned to unipolar CS versus RAA pacing. The PM was programmed in DDDR mode 1 month after implant. Each patient underwent four study phases of equal duration: (1) unipolar, single site (CS or RAA) pacing with the AF algorithm ON (atrial lower rate = 0 ppm); (2) unipolar, single site pacing with the AF algorithm OFF (atrial lower rate = 70 bpm); (3) bipolar, dual-site pacing with AF algorithm ON; (4) bipolar, dual-site pacing with the AF algorithm OFF. Among 40 patients (56%), who completed the follow-up (15 +/- 4 months) no difference was observed in the mean number of automatic mode switch (AMS) corrected for the duration of follow-up, in unipolar (5.6 +/- 22.8 vs 2.6 +/- 5.5) or bipolar mode (3.3 +/- 12.7 vs 2.1 +/- 4.9) with, respectively, the algorithm OFF or ON. With the AF prevention algorithm ON, the percentage of atrial pacing increased significantly from 78.7 +/- 22.1% to 92.4 +/- 4.9% (P < 0.001), while the average ventricular heart rate was significantly lower with the algorithm ON (62.4 +/- 17.5 vs 79.9 +/- 3 bpm (P < 0.001). The AF prevention algorithm increased the percentage of atrial pacing significantly, regardless of the atrial pulse configuration and pacing site, while maintaining a slower ventricular heart rate. It had no impact on the number of AMS in the unipolar and bipolar modes in patients with SSS.

  8. Quantitative Analysis of Electro-Anatomical Maps: Application to an Experimental Model of Left Bundle Branch Block/Cardiac Resynchronization Therapy

    PubMed Central

    Duchateau, Nicolas; Kostantyn Butakov, Constantine Butakoff; Andreu, David; Fernández-Armenta, Juan; Bijnens, Bart; Berruezo, Antonio; Sitges, Marta; Camara, Oscar

    2017-01-01

    Electro-anatomical maps (EAMs) are commonly acquired in clinical routine for guiding ablation therapies. They provide voltage and activation time information on a 3-D anatomical mesh representation, making them useful for analyzing the electrical activation patterns in specific pathologies. However, the variability between the different acquisitions and anatomies hampers the comparison between different maps. This paper presents two contributions for the analysis of electrical patterns in EAM data from biventricular surfaces of cardiac chambers. The first contribution is an integrated automatic 2-D disk representation (2-D bull’s eye plot) of the left ventricle (LV) and right ventricle (RV) obtained with a quasi-conformal mapping from the 3-D EAM meshes, that allows an analysis of cardiac resynchronization therapy (CRT) lead positioning, interpretation of global (total activation time), and local indices (local activation time (LAT), surrogates of conduction velocity, inter-ventricular, and transmural delays) that characterize changes in the electrical activation pattern. The second contribution is a set of indices derived from the electrical activation: speed maps, computed from LAT values, to study the electrical wave propagation, and histograms of isochrones to analyze regional electrical heterogeneities in the ventricles. We have applied the proposed methods to look for the underlying physiological mechanisms of left bundle branch block (LBBB) and CRT, with the goal of optimizing the therapy by improving CRT response. To better illustrate the benefits of the proposed tools, we created a set of synthetically generated and fully controlled activation patterns, where the proposed representation and indices were validated. Then, the proposed analysis tools are used to analyze EAM data from an experimental swine model of induced LBBB with an implanted CRT device. We have analyzed and compared the electrical activation patterns at baseline, LBBB, and CRT stages in four animals: two without any structural disease and two with an induced infarction. By relating the CRT lead location with electrical dyssynchrony, we evaluated current hypotheses about lead placement in CRT and showed that optimal pacing sites should target the RV lead close to the apex and the LV one distant from it. PMID:29164019

  9. Effects of enhanced pacing modalities on health care resource utilization and costs in bradycardia patients: An analysis of the randomized MINERVA trial.

    PubMed

    Boriani, Giuseppe; Manolis, Antonis S; Tukkie, Raymond; Mont, Lluis; Pürerfellner, Helmut; Santini, Massimo; Inama, Giuseppe; Serra, Paolo; Gulizia, Michele; Samoilenko, Igor Vasilyevich; Wolff, Claudia; Holbrook, Reece; Gavazza, Federica; Padeletti, Luigi

    2015-06-01

    Many patients who suffer from bradycardia and need cardiac pacing also have atrial fibrillation (AF). New pacemaker algorithms, such as atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), have been specifically designed to reduce AF occurrence and duration and to minimize the detrimental effects of right ventricular pacing. The randomized MINimizE Right Ventricular pacing to prevent Atrial fibrillation and heart failure trial established that DDDRP + MVP pacing modality reduced permanent AF in bradycardia patients as compared with standard dual-chamber pacing (DDDR). The aim of this study was to estimate the cost savings due to lower AF-related health care utilization events based on health care costs from the United States and the European Union. Dual-chamber pacemaker patients with a history of paroxysmal or persistent AF were randomly assigned to receive DDDR (n = 385) or the advanced features (DDDRP + MVP; n = 383). We used published health care costs from the United States and the European Union (Italy, Spain, and the United Kingdom) to estimate the costs associated with AF-related hospitalizations and emergency visits. The rate of AF-related hospitalizations was significantly lower in the DDDRP + MVP group than in the conventional pacemaker group (DDDR group; 42% reduction; incidence rate ratio 0.58). Similarly, a significant reduction of 68% was observed for AF-related emergency department visits (incidence rate ratio 0.32; P < .001). As a consequence, DDDRP + MVP could potentially reduce health care costs by 40%-44%. Over a ten-year period, the cost savings per 100 patients ranged from $35,702 in the United Kingdom to $121,831 in the United States. New pacing algorithms such as DDDRP + MVP used in the MINimizE Right Ventricular pacing to prevent Atrial fibrillation and heart failure trial successfully reduced AF-related health care utilization, resulting in significant cost savings to payers. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. The effect of atrial-based pacing on exercise capacity as measured by the 6-minute walk test: a substudy of the Canadian Trial of Physiological Pacing (CTOPP).

    PubMed

    Baranchuk, Adrian; Healey, Jeff S; Thorpe, Kevin E; Morillo, Carlos A; Nair, Girish; Crystal, Eugene; Kerr, Charles R; Connolly, Stuart J

    2007-08-01

    Although several randomized trials have detected no reduction in major cardiovascular events with the routine use of dual-chamber as opposed to ventricular pacemakers, many individuals continue to advocate their use as a means of improving exercise capacity. The Canadian Trial of Physiological Pacing (CTOPP) trial is the largest trial comparing ventricular pacing to atrial-based pacing (atrial or dual-chamber) in patients with bradycardia. All patients in this trial were asked to complete a 6-minute hall walk test (6MWT) at the time of their first study follow-up. The distance walked in 6 minutes and the patient's heart rate before and immediately after the walk were recorded. Of the 2568 patients in the CTOPP, 76% completed the 6MWT. The mean distance walked was 350 +/- 127 m in the ventricular pacing group and 356 +/- 127 m in the atrial-based group (P = NS). Similarly, there was no difference in the change in heart rate between the two groups (17 +/- 13 vs. 18 +/- 12 bpm: P = NS). However, among patients with an unpaced heart rate of

  11. 42 CFR 460.116 - Explanation of rights.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Rights § 460.116 Explanation of rights. (a) Written policies. A PACE...

  12. 42 CFR 460.116 - Explanation of rights.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Rights § 460.116 Explanation of rights. (a) Written policies. A PACE...

  13. The Effect of Right Ventricular Apical and Nonapical Pacing on the Short- and Long-Term Changes in Left Ventricular Ejection Fraction: A Systematic Review and Meta-Analysis of Randomized-Controlled Trials.

    PubMed

    Hussain, Mohammad Akhtar; Furuya-Kanamori, Luis; Kaye, Gerald; Clark, Justin; Doi, Suhail A R

    2015-09-01

    The right ventricular apex (RVA) is the traditional lead site for chronic pacing but in some patients may cause impaired left ventricular (LV) systolic function over time. Comparisons with right ventricular nonapical (RVNA) pacing sites have generated inconsistent results and recent meta-analyses have demonstrated unclear benefit due to heterogeneity across studies. A systematic search for randomized controlled trials that compared LV ejection fraction (LVEF) outcomes between RVNA and RVA pacing was performed up to October 2014. Twenty-four studies (n = 1,628 patients) met the inclusion criteria. To avoid between study heterogeneity two homogenous groups were created; group 1 where studies reported a difference (in favor of RVNA pacing) and group 2 where studies reported no difference between pacing sites. For group 1, weighted mean difference between RVNA and RVA pacing in terms of LVEF at follow-up was 5.40% (95% confidence interval [CI]: 3.94-6.87), related in part to group one's RVA arm demonstrating a significant reduction (mean loss -3.31%; 95% CI: -6.19 to -0.43) in LVEF between study baseline and end of follow-up. Neither of these finding were seen in group 2. Weighted regression modeling demonstrated that inclusion of poor baseline LVEF (<40%) in combination with greater than 12 months follow-up was three times more common in group 1 compared to group 2 (weighted relative risk 2.82; 95% CI: 1.03-7.72; P = 0.043). In patients requiring chronic right ventricular pacing where there is inclusion of impaired baseline LVEF (<40%), RVA pacing is associated with deterioration in LV function relative to RVNA pacing. © 2015 Wiley Periodicals, Inc.

  14. Validation of criteria for selective his bundle and para-hisian permanent pacing.

    PubMed

    Cantù, F; De Filippo, P; Cardano, P; De Luca, A; Gavazzi, A

    2006-12-01

    His Bundle (HB) pacing is a valid alternative to right ventricular pacing for patients with preserved His-ventricle conduction who are candidates for permanent stimulation. Permanent pacing in the HB area enables Selective HB pacing (SHBP) or para-Hisian pacing (PHP) to be achieved. The aim of our study was to draw up a set of easy criteria to differentiate and validate the two kinds of stimulations according to the pacing output and the ECG/EKG signals. From February to July 2005, 17 patients eligible for a pacemaker (PM) procedure underwent implantation with the Medtronic SelectSecure lead (Medtronic, Minneapolis, MN, USA) screwed into the HB area.SHBP was defined when the intrinsic QRS was equal, in both duration and morphology, to the paced QRS, the His-Ventricular (H-V) interval was equal to Pace-Ventricular interval (Vp-V) and, at low output, only the HB was captured, while increasing the output resulted in both the HB and right ventricular (RV) being captured (widening of QRS at high output). Conversely, PHP was defined when the intrinsic QRS differed from the paced one, either in morphology or in duration and, at high output, both the RV and HB were captured (non-SHBP), while decreasing the output resulted in losing HB capture (widening of QRS at low output). According to these criteria, SHBP was achieved in 11 patients, while in the remaining 6, PHP was obtained. No adverse events were reported. The above criteria enabled SHBP and PHP to be validated easily and clearly. A longer follow-up will be needed in order to ascertain whether the clinical outcome of these two approaches differs.

  15. A proteomic approach reveals transient association of reticulocalbin-3, a novel member of the CREC family, with the precursor of subtilisin-like proprotein convertase, PACE4

    PubMed Central

    Tsuji, Akihiko; Kikuchi, Yayoi; Sato, Yukimi; Koide, Shizuyo; Yuasa, Keizo; Nagahama, Masami; Matsuda, Yoshiko

    2006-01-01

    SPCs (subtilisin-like proprotein convertases) are a family of seven structurally related serine endoproteases that are involved in the proteolytic activation of proproteins. In an effort to examine the substrate protein for PACE4 (paired basic amino-acid-cleaving enzyme-4), an SPC, a potent protein inhibitor of PACE4, an α1-antitrypsin RVRR (Arg-Val-Arg-Arg) variant, was expressed in GH4C1 cells. Ectopic expression of the RVRR variant caused accumulation of the 48 kDa protein in cells. Sequence analysis indicates that the 48 kDa protein is a putative Ca2+-binding protein, RCN-3 (reticulocalbin-3), which had previously been predicted by bioinformatic analysis of cDNA from the human hypothalamus. RCN-3 is a member of the CREC (Cab45/reticulocalbin/ERC45/calumenin) family of multiple EF-hand Ca2+-binding proteins localized to the secretory pathway. The most interesting feature of the RCN-3 sequence is the presence of five Arg-Xaa-Xaa-Arg motifs, which represents the target sequence of SPCs. Biosynthetic studies showed that RCN-3 is transiently associated with proPACE4, but not with mature PACE4. Inhibition of PACE4 maturation by a Ca2+ ionophore resulted in accumulation of the proPACE4–RCN-3 complex in cells. Furthermore, autoactivation and secretion of PACE4 was increased upon co-expression with RCN-3. Our findings suggest that selective and transient association of RCN-3 with the precursor of PACE4 plays an important role in the biosynthesis of PACE4. PMID:16433634

  16. Role of apamin-sensitive small conductance calcium-activated potassium currents in long-term cardiac memory in rabbits.

    PubMed

    Yin, Dechun; Chen, Mu; Yang, Na; Wu, Adonis Z; Xu, Dongzhu; Tsai, Wei-Chung; Yuan, Yuan; Tian, Zhipeng; Chan, Yi-Hsin; Shen, Changyu; Chen, Zhenhui; Lin, Shien-Fong; Weiss, James N; Chen, Peng-Sheng; Everett, Thomas H

    2018-05-01

    Apamin-sensitive small conductance calcium-activated K current (I KAS ) is up-regulated during ventricular pacing and masks short-term cardiac memory (CM). The purpose of this study was to determine the role of I KAS in long-term CM. CM was created with 3-5 weeks of ventricular pacing and defined by a flat or inverted T wave off pacing. Epicardial optical mapping was performed in both paced and normal ventricles. Action potential duration (APD 80 ) was determined during right atrial pacing. Ventricular stability was tested before and after I KAS blockade. Four paced hearts and 4 normal hearts were used for western blotting and histology. There were no significant differences in either echocardiographic parameters or fibrosis levels between groups. Apamin induced more APD 80 prolongation in CM than in normal ventricles (mean [95% confidence interval]: 9.6% [8.8%-10.5%] vs 3.1% [1.9%-4.3%]; P <.001). Apamin significantly lengthened APD 80 in the CM model at late activation sites, indicating significant I KAS up-regulation at those sites. The CM model also had altered Ca 2+ handling, with the 50% Ca 2+ transient duration and amplitude increased at distal sites compared to a proximal site (near the pacing site). After apamin, the CM model had increased ventricular fibrillation (VF) inducibility (paced vs control: 33/40 (82.5%) vs 7/20 (35%); P <.001) and longer VF durations (124 vs 26 seconds; P <.001). Chronic ventricular pacing increases Ca 2+ transients at late activation sites, which activates I KAS to maintain repolarization reserve. I KAS blockade increases VF vulnerability in chronically paced rabbit ventricles. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Pulmonary vein isolation using a pace-capture-guided versus an adenosine-guided approach: effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study.

    PubMed

    Andrade, Jason G; Pollak, Scott J; Monir, George; Khairy, Paul; Dubuc, Marc; Roy, Denis; Talajic, Mario; Deyell, Marc; Rivard, Léna; Thibault, Bernard; Guerra, Peter G; Nattel, Stanley; Macle, Laurent

    2013-12-01

    Atrial fibrillation recurrence after pulmonary vein (PV) isolation is associated with PV to left atrium reconduction. We prospectively studied the use of 2 procedural techniques designed to facilitate identification of residual gaps within the index ablation line. After wide circumferential PV isolation, 40 patients received additional ablation targeted at locations of left atrial capture during high-output pacing (pace-capture group), while 40 patients underwent adenosine testing with targeted ablation at sites of dormant conduction (adenosine group). Patients were followed up at 3, 6, and 12 months. After PV isolation, high-output pace-capture was documented in 39 PVs (25%; 50% of patients) in the pace-capture group. Dormant conduction was unmasked in 34 PVs (22%; 53% of patients) in the adenosine group. A subset of 25 patients in the pace-capture group underwent adenosine testing without targeted ablation of dormant conduction. In these patients, only 10 out of 86 PVs (11.6%; 24% of patients) demonstrated dormant conduction after the elimination of local pace-capture. At a follow-up of 329±124 days, the single procedure off antiarrhythmic drug freedom from recurrent atrial fibrillation was 67.5% in the adenosine group and 65.0% in the pace-capture group (P=0.814). Procedure duration and fluoroscopy time were significantly longer in the pace-capture group (P=0.002 and P<0.001), whereas radiofrequency ablation time was comparable (P=0.192). The use of high-output pacing post-PV isolation results in a significant reduction in the incidence of dormant conduction with a comparable long-term freedom from recurrent atrial fibrillation (versus adenosine-guided ablation). The use of these approaches requires evaluation in a long-term prospective randomized study. [corrected].

  18. 42 CFR 460.18 - CMS evaluation of applications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.18 CMS evaluation of applications...

  19. 42 CFR 460.22 - Service area designation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.22 Service area designation. (a) An...

  20. 42 CFR 460.20 - Notice of CMS determination.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.20 Notice of CMS determination. (a...

  1. 42 CFR 460.71 - Oversight of direct participant care.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Administrative Requirements § 460.71 Oversight of direct participant care...

  2. 42 CFR 460.94 - Required services for Medicare participants.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Services § 460.94 Required services for Medicare participants. (a) Except...

  3. 42 CFR 460.18 - CMS evaluation of applications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.18 CMS evaluation of applications...

  4. 42 CFR 460.22 - Service area designation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.22 Service area designation. (a) An...

  5. 42 CFR 460.94 - Required services for Medicare participants.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Services § 460.94 Required services for Medicare participants. (a) Except...

  6. 42 CFR 460.20 - Notice of CMS determination.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.20 Notice of CMS determination. (a...

  7. Effects of generation mode in fMRI adaptations of semantic fluency: Paced production and overt speech

    PubMed Central

    Basho, Surina; Palmer, Erica D.; Rubio, Miguel A.; Wulfeck, Beverly; Müller, Ralph-Axel

    2007-01-01

    Verbal fluency is a widely used neuropsychological paradigm. In fMRI implementations, conventional unpaced (self-paced) versions are suboptimal due to uncontrolled timing of responses, and overt responses carry the risk of motion artifact. We investigated the behavioral and neurofunctional effects of response pacing and overt speech in semantic category-driven word generation. Twelve right-handed adults (8 female) ages 21–37 were scanned in four conditions each: Paced-Overt, Paced-Covert, Unpaced-Overt, and Unpaced-Covert. There was no significant difference in the number of exemplars generated between overt versions of the paced and unpaced conditions. Imaging results for category-driven word generation overall showed left-hemispheric activation in inferior frontal cortex, premotor cortex, cingulate gyrus, thalamus, and basal ganglia. Direct comparison of generation modes revealed significantly greater activation for the paced compared to unpaced conditions in right superior temporal, bilateral middle frontal, and bilateral anterior cingulate cortex, including regions associated with sustained attention, motor planning, and response inhibition. Covert (compared to overt) conditions showed significantly greater effects in right parietal and anterior cingulate, as well as left middle temporal and superior frontal regions. We conclude that paced overt paradigms are useful adaptations of conventional semantic fluency in fMRI, given their superiority with regard to control over and monitoring of behavioral responses. However, response pacing is associated with additional non-linguistic effects related to response inhibition, motor preparation, and sustained attention. PMID:17292926

  8. Capture of activation during ventricular arrhythmia using distributed stimulation.

    PubMed

    Meunier, Jason M; Ramalingam, Sanjiv; Lin, Shien-Fong; Patwardhan, Abhijit R

    2007-04-01

    Results of previous studies suggest that pacing strength stimuli can capture activation during ventricular arrhythmia locally near pacing sites. The existence of spatio-temporal distribution of excitable gap during arrhythmia suggests that multiple and timed stimuli delivered over a region may permit capture over larger areas. Our objective in this study was to evaluate the efficacy of using spatially distributed pacing (DP) to capture activation during ventricular arrhythmia. Data were obtained from rabbit hearts which were placed against a lattice of parallel wires through which biphasic pacing stimuli were delivered. Electrical activity was recorded optically. Pacing stimuli were delivered in sequence through the parallel wires starting with the wire closest to the apex and ending with one closest to the base. Inter-stimulus delay was based on conduction velocity. Time-frequency analysis of optical signals was used to determine variability in activation. A decrease in standard deviation of dominant frequencies of activation from a grid of locations that spanned the captured area and a concurrence with paced frequency were used as an index of capture. Results from five animals showed that the average standard deviation decreased from 0.81 Hz during arrhythmia to 0.66 Hz during DP at pacing cycle length of 125 ms (p = 0.03) reflecting decreased spatio-temporal variability in activation during DP. Results of time-frequency analysis during these pacing trials showed agreement between activation and paced frequencies. These results show that spatially distributed and timed stimulation can be used to modify and capture activation during ventricular arrhythmia.

  9. A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia

    PubMed Central

    Michel, Miriam; Egender, Friedemann; Heßling, Vera; Dähnert, Ingo; Gebauer, Roman

    2016-01-01

    Background Postoperative junctional ectopic tachycardia (JET) occurs frequently after pediatric cardiac surgery. R-wave synchronized atrial (AVT) pacing is used to re-establish atrioventricular synchrony. AVT pacing is complex, with technical pitfalls. We sought to establish and to test a low-cost simulation model suitable for training and analysis in AVT pacing. Methods A simulation model was developed based on a JET simulator, a simulation doll, a cardiac monitor, and a pacemaker. A computer program simulated electrocardiograms. Ten experienced pediatric cardiologists tested the model. Their performance was analyzed using a testing protocol with 10 working steps. Results Four testers found the simulation model realistic; 6 found it very realistic. Nine claimed that the trial had improved their skills. All testers considered the model useful in teaching AVT pacing. The simulation test identified 5 working steps in which major mistakes in performance test may impede safe and effective AVT pacing and thus permitted specific training. The components of the model (exclusive monitor and pacemaker) cost less than $50. Assembly and training-session expenses were trivial. Conclusions A realistic, low-cost simulation model of AVT pacing is described. The model is suitable for teaching and analyzing AVT pacing technique. PMID:26943363

  10. Right Ventricular Pacing for Assessment of Cavo-Tricuspid Isthmus Block.

    PubMed

    Venkataraman, Ganesh; Wish, Marc; Friehling, Ted; Strickberger, S Adam

    2016-01-01

    Background: Cavo-tricuspid isthmus (CTI) dependent atrial flutter is typically treated with cardiac ablation. Standard techniques to assess CTI block after ablation can be technically challenging. Right ventricular (RV) pacing may allow for another technique to assess CTI block after ablation. Objective: The purpose of this study was to evaluate RV pacing as a method to assess CTI block after ablation of CTI dependent atrial flutter, and define endpoints of ablation using this technique. Methods: 28 patients undergoing ablation of CTI dependent atrial flutter with intact ventriculoatrial (VA) conduction were prospectively enrolled in this study and underwent the RV pacing protocol, as well as standard coronary sinus (CS) pacing techniques to assess CTI block. Results: The mean trans-isthmus conduction interval during CS pacing (TICI CS ) at 600 and 400ms after CTI ablation was 168 +/- 9ms and 175 +/- 18ms, respectively. The mean trans-isthmus conduction interval during RV pacing (TICI RV ) at 600ms and 400ms after CTI ablation was 109 +/- 5ms and 111 +/- 5ms, respectively. A TICI RV >100ms was associated with a successful outcome after CTI ablation. Conclusions: RV pacing may add incremental value in the assessment of CTI block in patients undergoing ablation of CTI dependent atrial flutter.

  11. Kinematic hand parameters in front crawl at different paces of swimming.

    PubMed

    Samson, Mathias; Monnet, Tony; Bernard, Anthony; Lacouture, Patrick; David, Laurent

    2015-11-05

    The aim of this study was to investigate the evolution of kinematic hand parameters (sweepback angle, angle of attack, velocity, acceleration and orientation of the hand relative to the absolute coordinate system) throughout an aquatic stroke and to study the possible modifications caused by a variation of the swimming pace. Seventeen competitive swimmers swam at long distance, middle distance and sprint paces. Parameters were calculated from the trajectory of seven markers on the hand measured with an optoelectronic system. Results showed that kinematic hand parameters evolve differently depending on the pace. Angle of attack, sweepback angle, acceleration and orientation of the hand do not vary significantly. The velocity of the hand increases when the pace increases, but only during the less propulsive phases (entry and stretch and downsweep to catch). The more the pace increases and the more the absolute durations of the entry and stretch and downsweep to catch phases decrease. Absolute durations of the insweep and upsweep phases remain constant. During these phases, the propulsive hand forces calculated do not vary significantly when the pace increases. The increase of swimming pace is then explained by the swimmer's capacity to maintain propulsive phases rather than increasing the force generation within each cycle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. PACE and the Medicare+Choice risk-adjusted payment model.

    PubMed

    Temkin-Greener, H; Meiners, M R; Gruenberg, L

    2001-01-01

    This paper investigates the impact of the Medicare principal inpatient diagnostic cost group (PIP-DCG) payment model on the Program of All-Inclusive Care for the Elderly (PACE). Currently, more than 6,000 Medicare beneficiaries who are nursing home certifiable receive care from PACE, a program poised for expansion under the Balanced Budget Act of 1997. Overall, our analysis suggests that the application of the PIP-DCG model to the PACE program would reduce Medicare payments to PACE, on average, by 38%. The PIP-DCG payment model bases its risk adjustment on inpatient diagnoses and does not capture adequately the risk of caring for a population with functional impairments.

  13. Implantable cardioverter defibrillator does not cure the heart.

    PubMed

    Sławuta, Agnieszka; Boczar, Krzysztof; Ząbek, Andrzej; Gajek, Jacek; Lelakowski, Jacek; Vijayaraman, Pugazhendhi; Małecka, Barbara

    2018-01-23

    A man with non-ischemic cardiomyopathy, EF 22%, permanent AF and ICD was admitted for elective device replacement. The need for the optimization of the ventricular rate and avoidance of right ventricular pacing made it necessary to up-grade the existing pacing system using direct His bundle pacing and dual chamber ICD. This enabled the regularization of ventricular rate, avoiding the RV pacing and optimize the beta-blocker dose. The one month follow-up already showed reduction in left ventricle diameter, improvement in ejection fraction, NYHA class decrease to II. The His bundle pacing enabled the optimal treatment of the patient resulting in excellent clinical improvement.

  14. The PACE trial: It's time to broaden perceptions and move on.

    PubMed

    Petrie, Keith J; Weinman, John

    2017-08-01

    The continued critiques of the PACE trial highlight how differing beliefs about the causes of chronic fatigue syndrome still influence how scientific studies in this area are accepted and evaluated. Causal beliefs about chronic fatigue syndrome and a modern version of Cartesian dualism are important in understanding the reaction to the PACE trial. The continued debate on the PACE trial seems to miss the fact that science is incremental. An unfortunate outcome of the PACE controversy and intimidation of researchers may be less research in the area. It is time to move on from criticism and collect more data on effective treatments.

  15. 42 CFR 460.150 - Eligibility to enroll in a PACE program.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Enrollment and Disenrollment § 460.150 Eligibility to enroll in a...

  16. 42 CFR 460.28 - Notice of CMS determination on waiver requests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.28 Notice of...

  17. 42 CFR 460.28 - Notice of CMS determination on waiver requests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Organization Application and Waiver Process § 460.28 Notice of...

  18. 42 CFR 460.150 - Eligibility to enroll in a PACE program.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Participant Enrollment and Disenrollment § 460.150 Eligibility to enroll in a...

  19. Colony pace: a life-history trait affecting social insect epidemiology.

    PubMed

    Buechel, Séverine Denise; Schmid-Hempel, Paul

    2016-01-13

    Among colonies of social insects, the worker turnover rate (colony 'pace') typically shows considerable variation. This has epidemiological consequences for parasites, because in 'fast-paced' colonies, with short-lived workers, the time of parasite residence in a given host will be reduced, and further transmission may thus get less likely. Here, we test this idea and ask whether pace is a life-history strategy against infectious parasites. We infected bumblebees (Bombus terrestris) with the infectious gut parasite Crithidia bombi, and experimentally manipulated birth and death rates to mimic slow and fast pace. We found that fewer workers and, importantly, fewer last-generation workers that are responsible for rearing sexuals were infected in colonies with faster pace. This translates into increased fitness in fast-paced colonies, as daughter queens exposed to fewer infected workers in the nest are less likely to become infected themselves, and have a higher chance of founding their own colonies in the next year. High worker turnover rate can thus act as a strategy of defence against a spreading infection in social insect colonies. © 2016 The Author(s).

  20. PACE4 regulates proliferation, migration and invasion in human breast cancer MDA-MB-231 cells.

    PubMed

    Wang, Feifei; Wang, Lin; Pan, Jihong

    2015-01-01

    PACE4 is one of the proprotein convertases (PC) that participate in the post-translational activation of inactive proteins, leading to mature, biologically active proteins. The processing reactions occur in pairs of basic amino acids. PACE4 is an extracellular PC that binds to growth factors and several components of the extracellular matrix contributing to tumor progression. In the present study, the PACE4 gene was silenced by small interfering RNA (siRNA), and the knockdown human breast cancer MDA-MB-231 cells showed significantly reduced proliferation, migration and invasion rates. Flow cytometry analysis indicated that downregulation of PACE4 increases the percentage of cells arrested at the G0/G1 phase. Moreover, the expression of genes involved in cell growth, invasion and adhesion, i.e., IGF-2, MMP9 and MPZL2 was significantly decreased following siRNA-mediated silencing of PACE4. Taken together, these results indicate that PACE4 plays an important role in human breast cancer, and that it might represent a novel target for breast cancer therapy.

  1. Experience With a Long-term Pulsatile Ventricular Assist Device as a Bridge to Heart Transplant in Adults.

    PubMed

    Gómez Bueno, Manuel; Segovia Cubero, Javier; Serrano Fiz, Santiago; Ugarte Basterrechea, Juan; Hernández Pérez, Francisco José; Goirigolzarri Artaza, Josebe; Castedo Mejuto, Evaristo; Burgos Lázaro, Raúl; García Montero, Carlos; Moñivas Palomero, Vanessa; Mingo Santos, Susana; González Román, Ana Isabel; Álvarez Avelló, José Manuel; Vidal Fernández, Mercedes; Forteza Gil, Alberto; Alonso-Pulpón, Luis

    2017-09-01

    Most long-term ventricular assist devices (VADs) that are currently implanted are intracorporeal continuous-flow devices. Their main limitations include their high cost and inability to provide biventricular support. The aim of this study was to describe the results of using paracorporeal pulsatile-flow VADs as a bridge to transplant (BTT) in adult patients. Retrospective analysis of the characteristics, complications, and outcomes of a single-center case series of consecutive patients treated with the EXCOR VAD as BTT between 2009 and 2015. During the study period, 25 VADs were implanted, 6 of them biventricular. Ventricular assist devices were indicated directly as a BTT in 12 patients and as a bridge to decision in 13 due to the presence of potentially reversible contraindications or chance of heart function recovery. Twenty patients (80%) were successfully bridged to heart transplant after a median of 112 days (range, 8-239). The main complications included infectious (52% of patients), neurological events (32%, half of them fatal), bleeding (28%), and VAD malfunction requiring component replacement (28%). Eighty percent of patients with the EXCOR VAD as BTT achieved the goal after an average of almost 4 months of support. The most frequent complications were infectious, and the most severe were neurological. In our enivonment, the use of these pulsatile-flow VAD as BTT is a feasible strategy that obtains similar outcomes to those of intracorporeal continuous-flow devices. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Feasibility of Biventricular Repair in Right Dominant Unbalanced Atrioventricular Septal Defect: A New Echocardiographic Metric to Refine Surgical Decision-Making.

    PubMed

    Lugones, Ignacio; Biancolini, María Fernanda; Biancolini, Julio César; Dios, Ana M S de; Lugones, Germán

    2017-07-01

    Unbalanced forms of atrioventricular septal defect continue to be challenging and present poor surgical outcomes. Echocardiographic indicators such as atrioventricular valve index, right ventricle/left ventricle inflow angle, and size of the ventricular septal defect have been identified as relevant discriminators that may guide surgical strategy. Our purpose is to describe another metric to refine surgical decision-making. We outline a geometrical description of the anatomic features of atrioventricular septal defect and describe equations that help explain the interplay between the main echocardiographic variables. A new metric called "indexed ventricular septal defect" is defined as the size of the defect in relation to the valve diameter. We derive a final equation relating this index with the atrioventricular valve index and the right ventricle/left ventricle inflow angle. In the light of that equation, we discuss the interdependence of variables and employ data from a Congenital Heart Surgeons' Society study to set the limits of the new index. Combined use of indexed ventricular septal defect and atrioventricular valve index might help clarify surgical decision-making in patients with mild and moderate unbalance (modified atrioventricular valve index between 0.2 and 0.39). For indexed ventricular septal defect smaller than 0.2, biventricular repair may be recommended. Between 0.2 and 0.35, this strategy could probably be achieved depending on other factors. However, other strategies should be considered for those patients showing an indexed ventricular septal defect between 0.35 and 0.5. For values above 0.5 to 0.55, univentricular palliation might be a reasonable strategy.

  3. Utility of a super-flexible three-dimensional printed heart model in congenital heart surgery.

    PubMed

    Hoashi, Takaya; Ichikawa, Hajime; Nakata, Tomohiro; Shimada, Masatoshi; Ozawa, Hideto; Higashida, Akihiko; Kurosaki, Kenichi; Kanzaki, Suzu; Shiraishi, Isao

    2018-05-28

    The objective of this study was to assess the utility of 3D printed heart models of congenital heart disease for preoperative surgical simulation. Twenty patient-specific 3D models were created between March 2015 and August 2017. All operations were performed by a young consultant surgeon who had no prior experience with complex biventricular repair. All 15 patients with balanced ventricles had outflow tract malformations (double-outlet right ventricle in 7 patients, congenitally corrected transposition of great arteries in 5, transposition of great arteries in 1, interrupted aortic arch Type B in 1, tetralogy of Fallot with pulmonary atresia and major aortopulmonary collateral arteries in 1). One patient had hypoplastic left heart complex, and the remaining 4 patients had a functional single ventricle. The median age at operation was 1.4 (range 0.1-5.9) years. Based on a multislice computed tomography data set, the 3D models were made of polyurethane resins using stereolithography as the printing technology and vacuum casting as the manufacturing method. All but 4 patients with a functional single ventricle underwent complete biventricular repair. The median cardiopulmonary bypass time and aortic cross-clamp time were 345 (110-570) min and 114 (35-293) min, respectively. During the median follow-up period of 1.3 (0.1-2.5) years, no mortality was observed. None of the patients experienced surgical heart block or systemic ventricular outflow tract obstruction. Three-dimensional printed heart models showed potential utility, especially in understanding the relationship between intraventricular communications and great vessels, as well as in simulation for creating intracardiac pathways.

  4. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    PubMed

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P < .001), but there was substantial overlap with pace capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete loss of pace capture directly along the circumferential ablation line correlates with entrance block in 95% of vein pairs and can be achieved without circular mapping catheter guidance. Thus, pace capture along the ablation line can be used to identify conduction gaps. Interestingly, more RF ablation energy was required to achieve loss of pace capture along the ablation line than for entrance block into PVs. Further study is warranted to determine whether this method results in more durable ablation lesions that reduce recurrence of AF. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Optogenetic pacing in Drosophila melanogaster (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Alex, Aneesh; Li, Airong; Men, Jing; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2016-03-01

    A non-invasive, contact-less cardiac pacing technology can be a powerful tool in basic cardiac research and in clinics. Currently, electrical pacing is the gold standard for cardiac pacing. Although highly effective in controlling the cardiac function, the invasive nature, non-specificity to cardiac tissues and possible tissue damage limits its capabilities. Optical pacing of heart is a promising alternative, which is non-invasive and more specific, has high spatial and temporal precision, and avoids shortcomings in electrical stimulation. Optical coherence tomography has been proved to be an effective technique in non-invasive imaging in vivo with ultrahigh resolution and imaging speed. In the last several years, non-invasive specific optical pacing in animal hearts has been reported in quail, zebrafish, and rabbit models. However, Drosophila Melanogaster, which is a significant model with orthologs of 75% of human disease genes, has rarely been studied concerning their optical pacing in heart. Here, we combined optogenetic control of Drosophila heartbeat with optical coherence microscopy (OCM) technique for the first time. The light-gated cation channel, channelrhodopsin-2 (ChR2) was specifically expressed by transgene as a pacemaker in drosophila heart. By stimulating the pacemaker with 472 nm pulsed laser light at different frequencies, we achieved non-invasive and more specific optical control of the Drosophila heart rhythm, which demonstrates the wide potential of optical pacing for studying cardiac dynamics and development. Imaging capability of our customized OCM system was also involved to observe the pacing effect visually. No tissue damage was found after long exposure to laser pulses, which proved the safety of optogenetic control of Drosophila heart.

  6. Pacing-induced chronic atrial fibrillation impairs sinus node function in dogs. Electrophysiological remodeling.

    PubMed

    Elvan, A; Wylie, K; Zipes, D P

    1996-12-01

    We assessed the effects of pacing-induced chronic atrial fibrillation (AF) on sinus node function, intra-atrial conduction, and atrial refractoriness. In 15 mongrel dogs (20 to 30 kg), AV nodal block was produced by radiofrequency catheter ablation, and a ventricular-inhibited (VVI) pacemaker (Minix 8330, Medtronic) was implanted and programmed to pace at 80 pulses per minute. In 11 of these dogs, right atrial endocardial pacing leads were connected to a pulse generator (Itrel 7432, Medtronic) and set at a rate of 20 Hz to induce AF. Corrected sinus node recovery time, P-wave duration, 24-hour Holter ECG to assess AF duration, maximal heart rate in response to isoproterenol (10 micrograms/min), intrinsic heart rate after administration of atropine (0.04 mg/kg) and propranolol (0.1 mg/kg), and atrial effective refractory periods (ERPs) were obtained at baseline (EPS-1) and after 2 to 6 weeks (EPS-2) of VVI pacing alone (n = 4) or VVI pacing and rapid atrial pacing (n = 11). At EPS-2, corrected sinus node recovery time and P-wave duration were prolonged, maximal heart rate and intrinsic heart rate were decreased, atrial ERPs were shortened, and the duration of AF was increased significantly compared with EPS-1. These changes partially reversed toward baseline 1 week after conversion to sinus rhythm. Sinus node function and AF inducibility observed in the control dogs that underwent ventricular pacing alone (n = 4) did not change. Pacing-induced chronic AF induces sinus node dysfunction, prolongs intra-atrial conduction time, shortens atrial refractoriness, and perpetuates AF, changes that reverse gradually after termination of AF.

  7. Pacing: A concept analysis of a chronic pain intervention

    PubMed Central

    Jamieson-Lega, Kathryn; Berry, Robyn; Brown, Cary A

    2013-01-01

    BACKGROUND: The intervention of pacing is regularly recommended for chronic pain patients. However, pacing is poorly defined and appears to be interpreted in varying, potentially contradictory manners within the field of chronic pain. This conceptual lack of clarity has implications for effective service delivery and for researchers’ ability to conduct rigorous study. An examination of the background literature demonstrates that while pacing is often one part of a multidisciplinary pain management program, outcome research is hindered by a lack of a clear and shared definition of this currently ill-defined construct. OBJECTIVES: To conduct a formal concept analysis of the term ‘pacing’. METHODS: A standardized concept analysis process (including literature scoping to identify all uses of the concept, analysis to determine defining attributes of the concept and identification of model, borderline and contrary cases) was used to determine what the concept of pacing does and does not represent within the current evidence base. RESULTS: A conceptual model including the core attributes of action, time, balance, learning and self-management emerged. From these attributes, an evidence-based definition for pacing was composed and distributed to stakeholders for review. After consideration of stakeholder feedback, the emergent definition of pacing was finalized as follows: “Pacing is an active self-management strategy whereby individuals learn to balance time spent on activity and rest for the purpose of achieving increased function and participation in meaningful activities”. CONCLUSION: The findings of the present concept analysis will help to standardize the use and definition of the term pacing across disciplines for the purposes of both pain management and research. PMID:23717825

  8. Determination of the optimal atrioventricular interval in sick sinus syndrome during DDD pacing.

    PubMed

    Kato, Masaya; Dote, Keigo; Sasaki, Shota; Goto, Kenji; Takemoto, Hiroaki; Habara, Seiji; Hasegawa, Daiji; Matsuda, Osamu

    2005-09-01

    Although the AAI pacing mode has been shown to be electromechanically superior to the DDD pacing mode in sick sinus syndrome (SSS), there is evidence suggesting that during AAI pacing the presence of natural ventricular activation pattern is not enough for hemodynamic benefit to occur. Myocardial performance index (MPI) is a simply measurable Doppler-derived index of combined systolic and diastolic myocardial performance. The aim of this study was to investigate whether AAI pacing mode is electromechanically superior to the DDD mode in patients with SSS by using Doppler-derived MPI. Thirty-nine SSS patients with dual-chamber pacing devices were evaluated by using Doppler echocardiography in AAI mode and DDD mode. The optimal atrioventricular (AV) interval in DDD mode was determined and atrial stimulus-R interval was measured in AAI mode. The ratio of the atrial stimulus-R interval to the optimal AV interval was defined as relative AV interval (rAVI) and the ratio of MPI in AAI mode to that in DDD mode was defined as relative MPI (rMPI). The rMPI was significantly correlated with atrial stimulus-R interval and rAVI (r = 0.57, P = 0.0002, and r = 0.67, P < 0.0001, respectively). A cutoff point of 1.73 for rAVI provided optimum sensitivity and specificity for rMPI >1 based on the receiver operator curves. Even though the intrinsic AV conduction is moderately prolonged, some SSS patients with dual-chamber pacing devices benefit from the ventricular pacing with optimal AV interval. MPI is useful to determine the optimal pacing mode in acute experiment.

  9. Pace Speaks Across America - February 21 2007 - U.S. Department of Defense

    Science.gov Websites

    Washington State, Oregon, Alaska and Florida. Pace Discusses Force Levels, Military Challenges WASHINGTON Iraq, force levels or tour lengths, Marine Gen. Peter Pace is eager to answer frankly and completely

  10. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  11. [Clinical experiences with four newly developed, surface modified stimulation electrodes].

    PubMed

    Winter, U J; Fritsch, J; Liebing, J; Höpp, H W; Hilger, H H

    1993-05-01

    Newly developed pacing electrodes with so-called porous surfaces promise a significantly improved post-operative pacing and sensing threshold. We therefore investigated four newly developed leads (ELA-PMCF-860 n = 10; Biotronik-60/4-DNP n = 10, CPI-4010 n = 10, Intermedics-421-03-Biopore n = 6) connected to two different pacing devices (Intermedics NOVA II, Medtronic PASYS) in 36 patients (18 men, 18 women, age: 69.7 +/- 9.8 years) suffering from symptomatic bradycardia. The individual electrode maturation process was investigated by means of repeated measurements of pacing threshold, electrode impedance in acute, subacute, and chronic phase, as well as energy consumption and sensing behavior in the chronic phase. However, with the exception of the 4010, the investigated leads showed largely varying values of the pacing threshold with individual peaks occurring from the second up to the 13th week. All leads had nearly similar chronic pacing thresholds (PMCF 0.13 +/- 0.07; DNP 0.25 +/- 0.18; Biopore 0.15 +/- 0.05; 4010 0.14 +/- 0.05 ms). Impedance measurements revealed higher, but not significantly different values for the DNP (PMCF 582 +/- 112, DNP 755 +/- 88, Biopore 650 +/- 15, 4010 718 +/- 104 Ohm). Despite differing values for pacing threshold and impedance, the energy consumption in the chronic phase during threshold-adapted, but secure stimulation (3 * impulse-width at pacing threshold) were comparable.

  12. Staying Connected on the Road: A Comparison of Different Types of Smart Phone Use in a Driving Simulator

    PubMed Central

    McNabb, Jaimie; Gray, Rob

    2016-01-01

    Previous research on smart phone use while driving has primarily focused on phone calls and texting. Drivers are now increasingly using their phone for other activities during driving, in particular social media, which have different cognitive demands. The present study compared the effects of four different smart phone tasks on car-following performance in a driving simulator. Phone tasks were chosen that vary across two factors: interaction medium (text vs image) and task pacing (self-paced vs experimenter-paced) and were as follows: Text messaging with the experimenter (text/other-paced), reading Facebook posts (text/self-paced), exchanging photos with the experimenter via Snapchat (image, experimenter -paced), and viewing updates on Instagram (image, experimenter -paced). Drivers also performed a driving only baseline. Brake reaction times (BRTs) were significantly greater in the text-based conditions (Mean = 1.16 s) as compared to both the image-based conditions (Mean = 0.92 s) and the baseline (0.88 s). There was no significant difference between BRTs in the image-based and baseline conditions and there was no significant effect of task-pacing. Similar results were obtained for Time Headway variability. These results are consistent with the picture superiority effect found in memory research and suggest that image-based interfaces could provide safer ways to “stay connected” while driving than text-based interfaces. PMID:26886099

  13. Antiarrhythmic properties of atrial pacing.

    PubMed

    Kliś, Magdalena; Sławuta, Agnieszka; Gajek, Jacek

    2017-01-01

    Bradycardia, atrial stretch and dilatation, autonomic nervous system disorders, and the presence of triggers such as atrial premature contractions, are factors which predispose a person to paroxysmal AF. Atrial pacing not only eliminates bradycardia but also prevents atrial premature contractions and dispersion of refractoriness, which are a substrate for atrial fibrillation. As the prolonged duration of atrial activation during pacing, especially from locations changing the physiological pattern of this activation (right atrium lateral wall, right atrium appendage), negatively influences both a mechanical and an electrical function of the atria, the atrial pacing site affects an atrial arrhythmogenesis. A conventional atrial lead location in the right atrium appendage causes non-physiological activation propagation, resulting in a prolongation of the activation time of both atria. This location is optimal according to a passive fixation of the atrial lead but the available contemporary active fixation leads could potentially be located in any area of the atrium. There is growing evidence of the benefit of pacing, imitating the physiological propagation of impulses within the atria. It seems that the Bachmann's bundle pacing is the best pacing site within the atria, not only positively influencing the atrial mechanical function but also best fulfilling the so-called atrial resynchronization function, in particular in patients with interatrial conduction delay. It can be effectively achieved using only one atrial electrode, and the slight shortening of atrioventricular conduction provides an additional benefit of this atrial pacing site.

  14. Interaction between spiral and paced waves in cardiac tissue

    PubMed Central

    Agladze, Konstantin; Kay, Matthew W.; Krinsky, Valentin; Sarvazyan, Narine

    2010-01-01

    For prevention of lethal arrhythmias, patients at risk receive implantable cardioverter-defibrillators, which use high-frequency antitachycardia pacing (ATP) to convert tachycardias to a normal rhythm. One of the suggested ATP mechanisms involves paced-induced drift of rotating waves followed by their collision with the boundary of excitable tissue. This study provides direct experimental evidence of this mechanism. In monolayers of neonatal rat cardiomyocytes in which rotating waves of activity were initiated by premature stimuli, we used the Ca2+-sensitive indicator fluo 4 to observe propagating wave patterns. The interaction of the spiral tip with a paced wave was then monitored at a high spatial resolution. In the course of the experiments, we observed spiral wave pinning to local heterogeneities within the myocyte layer. High-frequency pacing led, in a majority of cases, to successful termination of spiral activity. Our data show that 1) stable spiral waves in cardiac monolayers tend to be pinned to local heterogeneities or areas of altered conduction, 2) overdrive pacing can shift a rotating wave from its original site, and 3) the wave break, formed as a result of interaction between the spiral tip and a paced wave front, moves by a paced-induced drift mechanism to an area where it may become unstable or collide with a boundary. The data were complemented by numerical simulations, which was used to further analyze experimentally observed behavior. PMID:17384124

  15. Staying Connected on the Road: A Comparison of Different Types of Smart Phone Use in a Driving Simulator.

    PubMed

    McNabb, Jaimie; Gray, Rob

    2016-01-01

    Previous research on smart phone use while driving has primarily focused on phone calls and texting. Drivers are now increasingly using their phone for other activities during driving, in particular social media, which have different cognitive demands. The present study compared the effects of four different smart phone tasks on car-following performance in a driving simulator. Phone tasks were chosen that vary across two factors: interaction medium (text vs image) and task pacing (self-paced vs experimenter-paced) and were as follows: Text messaging with the experimenter (text/other-paced), reading Facebook posts (text/self-paced), exchanging photos with the experimenter via Snapchat (image, experimenter-paced), and viewing updates on Instagram (image, experimenter-paced). Drivers also performed a driving only baseline. Brake reaction times (BRTs) were significantly greater in the text-based conditions (Mean = 1.16 s) as compared to both the image-based conditions (Mean = 0.92 s) and the baseline (0.88 s). There was no significant difference between BRTs in the image-based and baseline conditions and there was no significant effect of task-pacing. Similar results were obtained for Time Headway variability. These results are consistent with the picture superiority effect found in memory research and suggest that image-based interfaces could provide safer ways to "stay connected" while driving than text-based interfaces.

  16. 42 CFR 460.76 - Transportation services.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Transportation services. 460.76 Section 460.76... ELDERLY (PACE) PACE Administrative Requirements § 460.76 Transportation services. (a) Safety, accessibility, and equipment. A PACE organization's transportation services must be safe, accessible, and...

  17. 42 CFR 460.76 - Transportation services.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Transportation services. 460.76 Section 460.76... ELDERLY (PACE) PACE Administrative Requirements § 460.76 Transportation services. (a) Safety, accessibility, and equipment. A PACE organization's transportation services must be safe, accessible, and...

  18. 42 CFR 460.76 - Transportation services.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Transportation services. 460.76 Section 460.76... ELDERLY (PACE) PACE Administrative Requirements § 460.76 Transportation services. (a) Safety, accessibility, and equipment. A PACE organization's transportation services must be safe, accessible, and...

  19. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    PubMed

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of pacing as part of device therapy for atrial arrhythmias.

  20. Effect of right ventricular pacing lead site on left ventricular function in patients with high-grade atrioventricular block: results of the Protect-Pace study.

    PubMed

    Kaye, Gerald C; Linker, Nicholas J; Marwick, Thomas H; Pollock, Lucy; Graham, Laura; Pouliot, Erika; Poloniecki, Jan; Gammage, Michael

    2015-04-07

    Chronic right ventricle (RV) apical (RVA) pacing is standard treatment for an atrioventricular (AV) block but may be deleterious to left ventricle (LV) systolic function. Previous clinical studies of non-apical pacing have produced conflicting results. The aim of this randomized, prospective, international, multicentre trial was to compare change in LV ejection fraction (LVEF) between right ventricular apical and high septal (RVHS) pacing over a 2-year study period. We randomized 240 patients (age 74 ± 11 years, 67% male) with a high-grade AV block requiring >90% ventricular pacing and preserved baseline LVEF >50%, to receive pacing at the RVA (n = 120) or RVHS (n = 120). At 2 years, LVEF decreased in both the RVA (57 ± 9 to 55 ± 9%, P = 0.047) and the RVHS groups (56 ± 10 to 54 ± 10%, P = 0.0003). However, there was no significant difference in intra-patient change in LVEF between confirmed RVA (n = 85) and RVHS (n = 83) lead position (P = 0.43). There were no significant differences in heart failure hospitalization, mortality, the burden of atrial fibrillation, or plasma brain natriutetic peptide levels between the two groups. A significantly greater time was required to place the lead in the RVHS position (70 ± 25 vs. 56 ± 24 min, P < 0.0001) with longer fluoroscopy times (11 ± 7 vs. 5 ± 4 min, P < 0.0001). In patients with a high-grade AV block and preserved LV function requiring a high percentage of ventricular pacing, RVHS pacing does not provide a protective effect on left ventricular function over RVA pacing in the first 2 years. ClinicalTrials.gov number NCT00461734. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  1. A Pilot Study on the Effects of Slow Paced Breathing on Current Food Craving.

    PubMed

    Meule, Adrian; Kübler, Andrea

    2017-03-01

    Heart rate variability biofeedback (HRV-BF) involves slow paced breathing (approximately six breaths per minute), thereby maximizing low-frequent heart rate oscillations and baroreflex gain. Mounting evidence suggests that HRV-BF promotes symptom reductions in a variety of physical and mental disorders. It may also positively affect eating behavior by reducing food cravings. The aim of the current study was to investigate if slow paced breathing can be useful for attenuating momentary food craving. Female students performed paced breathing either at six breaths per minute (n = 32) or at nine breaths per minute (n = 33) while watching their favorite food on the computer screen. Current food craving decreased during a first resting period, increased during paced breathing, and decreased during a second resting period in both conditions. Although current hunger increased in both conditions during paced breathing as well, it remained elevated after the second resting period in the nine breaths condition only. Thus, breathing rate did not influence specific food craving, but slow paced breathing appeared to have a delayed influence on state hunger. Future avenues are suggested for the study of HRV-BF in the context of eating behavior.

  2. Optogenetic pacing in Drosophila melanogaster

    PubMed Central

    Alex, Aneesh; Li, Airong; Tanzi, Rudolph E.; Zhou, Chao

    2015-01-01

    Electrical stimulation is currently the gold standard for cardiac pacing. However, it is invasive and nonspecific for cardiac tissues. We recently developed a noninvasive cardiac pacing technique using optogenetic tools, which are widely used in neuroscience. Optogenetic pacing of the heart provides high spatial and temporal precisions, is specific for cardiac tissues, avoids artifacts associated with electrical stimulation, and therefore promises to be a powerful tool in basic cardiac research. We demonstrated optogenetic control of heart rhythm in a well-established model organism, Drosophila melanogaster. We developed transgenic flies expressing a light-gated cation channel, channelrhodopsin-2 (ChR2), specifically in their hearts and demonstrated successful optogenetic pacing of ChR2-expressing Drosophila at different developmental stages, including the larva, pupa, and adult stages. A high-speed and ultrahigh-resolution optical coherence microscopy imaging system that is capable of providing images at a rate of 130 frames/s with axial and transverse resolutions of 1.5 and 3.9 μm, respectively, was used to noninvasively monitor Drosophila cardiac function and its response to pacing stimulation. The development of a noninvasive integrated optical pacing and imaging system provides a novel platform for performing research studies in developmental cardiology. PMID:26601299

  3. Heart rate autonomic regulation system at rest and during paced breathing among patients with CRPS as compared to age-matched healthy controls.

    PubMed

    Bartur, Gadi; Vatine, Jean-Jacques; Raphaely-Beer, Noa; Peleg, Sara; Katz-Leurer, Michal

    2014-09-01

    The objective of this study is to assess the autonomic nerve heart rate regulation system at rest and its immediate response to paced breathing among patients with complex regional pain syndrome (CRPS) as compared with age-matched healthy controls. Quasiexperimental. Outpatient clinic. Ten patients with CRPS and 10 age- and sex-matched controls. Participants underwent Holter ECG (NorthEast Monitoring, Inc., Maynard, MA, USA) recording during rest and biofeedback-paced breathing session. Heart rate variability (HRV), time, and frequency measures were assessed. HRV and time domain values were significantly lower at rest among patients with CRPS as compared with controls. A significant association was noted between pain rank and HRV frequency measures at rest and during paced breathing; although both groups reduced breathing rate significantly during paced breathing, HRV time domain parameters increased only among the control group. The increased heart rate and decreased HRV at rest in patients with CRPS suggest a general autonomic imbalance. The inability of the patients to increase HRV time domain values during paced breathing may suggest that these patients have sustained stress response with minimal changeability in response to slow-paced breathing stimuli. Wiley Periodicals, Inc.

  4. Positive pacing in elite IRONMAN triathletes.

    PubMed

    Angehrn, Nicole; Rüst, Christoph A.; Nikolaidis, Pantelis T.; Rosemann, Thomas; Knechtle, Beat

    2016-12-31

    Pacing is known to influence athletic performance. For the Ironman triathlon program, a positive pacing strategy, i.e., the continuous decrease of speed over time was recommended. By analyzing split times, we assessed the pacing strategies of the top 100 finishers of the cycling part of 13 Ironman races and of the running part of 11 Ironman races taking place in 2014. Furthermore, sex-associated differences in performance and pacing strategies were calculated. We analyzed 7,687 cycling and 11,894 running split times of 1,392 triathletes (1,263 men, 129 women). Changes in speed were assessed using mixed-effects regression analyses. A continuous decrease in speed was observed during cycling in 10/13 races, and during running in 11/11 races. In 6/13 races, women decreased their speed during cycling significantly more than men. The running part showed no significant difference of changes in speed between the sexes. In summary, in the Ironman races evaluated, a positive pacing strategy was adopted in most races. Women were slower than men in 6/13 cycling races, but there was no difference between men and women in the run splits. Women used the same pacing strategy as men.

  5. Towards PACE Atmospheric Correction, Aerosol and Cloud Products: Making Use of Expanded Spectral, Angular and Polarimetric Information.

    NASA Astrophysics Data System (ADS)

    Remer, L. A.; Boss, E.; Ahmad, Z.; Cairns, B.; Chowdhary, J.; Coddington, O.; Davis, A. B.; Dierssen, H. M.; Diner, D. J.; Franz, B. A.; Frouin, R.; Gao, B. C.; Garay, M. J.; Heidinger, A.; Ibrahim, A.; Kalashnikova, O. V.; Knobelspiesse, K. D.; Levy, R. C.; Omar, A. H.; Meyer, K.; Platnick, S. E.; Seidel, F. C.; van Diedenhoven, B.; Werdell, J.; Xu, F.; Zhai, P.; Zhang, Z.

    2017-12-01

    NASA's Science Team for the Plankton, Aerosol, Clouds, ocean Ecosystem (PACE) mission is concluding three years of study exploring the science potential of expanded spectral, angular and polarization capability for space-based retrievals of water leaving radiance, aerosols and clouds. The work anticipates future development of retrievals to be applied to the PACE Ocean Color Instrument (OCI) and/or possibly a PACE Multi-Angle Polarimeter (MAP). In this presentation we will report on the Science Team's accomplishments associated with the atmosphere (significant efforts are also directed by the ST towards the ocean). Included in the presentation will be sensitivity studies that explore new OCI capabilities for aerosol and cloud layer height, aerosol absorption characterization, cloud property retrievals, and how we intend to move from heritage atmospheric correction algorithms to make use of and adjust to OCI's hyperspectral and UV wavelengths. We will then address how capabilities will improve with the PACE MAP, how these capabilities from both OCI and MAP correspond to specific societal benefits from the PACE mission, and what is still needed to close the gaps in our understanding before the PACE mission can realize its full potential.

  6. Is Self-Paced Instruction Really Worth It?

    ERIC Educational Resources Information Center

    Roberson, J. A.; Crowe, C. T.

    1975-01-01

    Describes a self-paced, learning-for-mastery course in undergraduate fluid mechanics. Includes the method of course assessment, method of student evaluation, and a description of the instructor's role and work load. Summarizes aspects of self-paced instruction considered favorable and unfavorable. (GS)

  7. 42 CFR 460.76 - Transportation services.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Administrative Requirements § 460.76 Transportation services. (a) Safety... participants. (2) Handling emergency situations. (e) Changes in care plan. As part of the interdisciplinary...

  8. 42 CFR 460.76 - Transportation services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Administrative Requirements § 460.76 Transportation services. (a) Safety... participants. (2) Handling emergency situations. (e) Changes in care plan. As part of the interdisciplinary...

  9. 42 CFR 460.62 - Governing body.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE... patient care responsibilities. (5) Fiscal operations. (6) Development of policies on participant health and safety, including a comprehensive, systemic operational plan to ensure the health and safety of...

  10. Notation system and overlay diagrams for the analysis of paced electrocardiograms.

    PubMed

    Bernstein, A D; Parsonnet, V

    1983-01-01

    With the advent of adaptive dual-chamber pacing, the interaction between the pacemaker and the heart is becoming increasingly complex and the interpretation of paced electrocardiograms more difficult. We have developed a set of notation conventions for use in teaching and rhythm-strip analysis. Easily-drawn symbols delineate successful, unsuccessful, and inhibited pacing and sensing events as well as refractory and blanking periods. Another application is to generate movable transparent overlays after programming a pacemaker, to be used in interpreting subsequent rhythm strips.

  11. Comparison of right ventricular septal pacing and right ventricular apical pacing in patients receiving cardiac resynchronization therapy defibrillators: the SEPTAL CRT Study

    PubMed Central

    Leclercq, Christophe; Sadoul, Nicolas; Mont, Lluis; Defaye, Pascal; Osca, Joaquim; Mouton, Elisabeth; Isnard, Richard; Habib, Gilbert; Zamorano, Jose; Derumeaux, Genevieve; Fernandez-Lozano, Ignacio; Dupuis, Jean-Marc; Rouleau, Frédéric; Tassin, Aude; Bordachar, Pierre; Clémenty, Jacques; Lafitte, Stephane; Ploux, Sylvan; Reant, Patricia; Ritter, Philippe; Defaye, Pascal; Jacon, Peggy; Mondesert, Blandine; Saunier, Carole; Vautrin, Estelle; Kacet, Salem; Guedon-Moreau, Laurence; Klug, Didier; Kouakam, Claude; Marechaux, Sylvestre; Marquie, Christelle; Polge, Anne Sophie; Richardson, Marjorie; Chevallier, Philippe; De Breyne, Brigitte; Lotek, Marcin M.; Nonin, Emilie; Pineau, Julien; Deharo, Jean-Claude; Bastard, Emilie; Franceschi, Frédéric; Habib, Gilbert; Jego, Christophe; Peyrouse, Eric; Prevot, Sebastien; Saint-Joseph, Hôpital; Bremondy, Michel; Faure, Jacques; Ferracci, Ange; Lefevre, Jean; Pisapia, Andre; Davy, Jean-Marc; Cransac, Frederic; Cung, Tien Tri; Georger, Frederic; Pasquie, Jean-Luc; Raczka, Franck; Sportouch-Dukhan, Catherine; Sadoul, Nicolas; Blangy, Hugues; Bruntz, Jean-François; Freysz, Luc; Groben, Laurent; Huttin, Olivier; Bammert, Antoine; Burban, Marc; Cebron, Jean-Pierre; Gras, Daniel; Frank, Robert; Duthoit, Guillaume; Hidden-Lucet, Françoise; Himbert, Caroline; Isnard, Richard; Lacotte, Jérôme; Pousset, Françoise; Zerah, Thierry; Leclercq, Christophe; Bellouin, Annaïk; Crocq, Christophe; Deplace, Christian; Donal, Erwan; Hamon, Cécile; Mabo, Philippe; Romain, Olivier; Solnon, Aude; Frederic, Anselme; Bauer, Fabrice; Bernard, Mathieu; Godin, Benedicte; Kurtz, Baptiste; Savoure, Arnaud; Copie, Xavier; Lascault, Gilles; Paziaud, Olivier; Piot, Olivier; Touche, Thierry; Delay, Toulouse Marc; Chilon, Talia; Detis, Nicolas; Duparc, Alexandre; Hebrard, Aurélien; Massabuau, Pierre; Maury, Philippe; Mondoly, Pierre; Rumeau, Philippe; Pasteur, Clinique; Boveda, Serge; Adrover, Laurence; Combes, Nicolas; Deplagne, Antoine; Marco-Baertich, Isabelle; Fondard, Olivier; Martínez, Juan Gabriel; Ibañez Criado, José Luis; Ortuño, Diego; Mont, Lluis; Berruezo, Antonio; Eduard, Belu; Martín, Ana; Merschon, Franco M.; Sitges, Marta; Tolosana, José María; Vidal, Bárbara; Hebron, H. Valle; i Mitjans, Angel Moya; Rodriguez, Oscar Alcalde; Rodriguez Palomares, José Fernando; Rivas, Nuria; Teixidó, Gisela; de Hierro, H. Puerta; Lozano, Ignacio Fernández; Ruiz Bautista, Maria Lorena; Castro, Victor; Cavero, Miguel Angel; Gutierrez, Carlos; Ros, Natalia; de la Victoria, H. Virgen; Alzueta Rodriguez, Francisco Javier; Cabrera, Fernando; Cordero, Alberto Barrera; Peña, José Luis; de Valme Sevilla, H.; Gonzáles, Juan Lealdel Ojo; Garcia Medina, Mª Dolores; Jiménez, Ricardo Pavón; Villagomez, David; de la Salud Toledo, H. Virgen; Castellanos Martinez, Eduardo; Alcalá, Juan; Maicas, Carolina; Arias Palomares, Miguel Angel; Puchol, Alberto; Valencia, H. La Fé; OscaAsensi, Joaquim; Carmona, Anastasio Quesada; De Carranza, Mª José Sancho-Tello; De Ros, José Olagüe; Pareja, Enrique Castro; Pérez, Oscar Cano; Saez, Ana Osa; Hortega, H. Rio; Guilarte, Benito Herreros; Muñoz San Jose, Juan Francisco; Pérez Sanz, Teresa Myriam; Logeart, Damien; Gil, Maria Lopez; Leclercq, Christophe; Lozano, Ignacio Fernandez; de Hierro, H. Puerta; Derumeaux, Genevieve

    2016-01-01

    Abstract Aims Cardiac resynchronization therapy (CRT) is a recommended treatment of heart failure (HF) patients with depressed left ventricular ejection fraction and wide QRS. The optimal right ventricular (RV) lead position being a matter of debate, we sought to examine whether RV septal (RVS) pacing was not inferior to RV apical (RVA) pacing on left ventricular reverse remodelling in patients receiving a CRT-defibrillator. Methods and results Patients (n = 263, age = 63.4 ± 9.5 years) were randomly assigned in a 1:1 ratio to RVS (n = 131) vs. RVA (n = 132) pacing. Left ventricular end-systolic volume (LVESV) reduction between baseline and 6 months was not different between the two groups (−25.3 ± 39.4 mL in RVS group vs. −29.3 ± 44.5 mL in RVA group, P = 0.79). Right ventricular septal pacing was not non-inferior (primary endpoint) to RVA pacing with regard to LVESV reduction (average difference = −4.06 mL; P = 0.006 with a −20 mL non-inferiority margin). The percentage of ‘echo-responders’ defined by LVESV reduction >15% between baseline and 6 months was similar in both groups (50%) with no difference in the time to first HF hospitalization or death (P = 0.532). Procedural or device-related serious adverse events occurred in 68 patients (RVS = 37) with no difference between the two groups (P = 0.401). Conclusion This study demonstrates that septal RV pacing in CRT is non-inferior to apical RV pacing for LV reverse remodelling at 6 months with no difference in the clinical outcome. No recommendation for optimal RV lead position can hence be drawn from this study. ClinicalTrials. gov number NCT 00833352. PMID:26374852

  12. Reduction in unnecessary ventricular pacing fails to affect hard clinical outcomes in patients with preserved left ventricular function: a meta-analysis.

    PubMed

    Shurrab, Mohammed; Healey, Jeff S; Haj-Yahia, Saleem; Kaoutskaia, Anna; Boriani, Giuseppe; Carrizo, Aldo; Botto, Gianluca; Newman, David; Padeletti, Luigi; Connolly, Stuart J; Crystal, Eugene

    2017-02-01

    Several pacing modalities across multiple manufacturers have been introduced to minimize unnecessary right ventricular pacing. We conducted a meta-analysis to assess whether ventricular pacing reduction modalities (VPRM) influence hard clinical outcomes in comparison to standard dual-chamber pacing (DDD). An electronic search was performed using Cochrane Central Register, PubMed, Embase, and Scopus. Only randomized controlled trials (RCT) were included in this analysis. Outcomes of interest included: frequency of ventricular pacing (VP), incident persistent/permanent atrial fibrillation (PerAF), all-cause hospitalization and all-cause mortality. Odds ratios (OR) were reported for dichotomous variables. Seven RCTs involving 4119 adult patients were identified. Ventricular pacing reduction modalities were employed in 2069 patients: (MVP, Medtronic Inc.) in 1423 and (SafeR, Sorin CRM, Clamart) in 646 patients. Baseline demographics and clinical characteristics were similar between VPRM and DDD groups. The mean follow-up period was 2.5 ± 0.9 years. Ventricular pacing reduction modalities showed uniform reduction in VP in comparison to DDD groups among all individual studies. The incidence of PerAF was similar between both groups {8 vs. 10%, OR 0.84 [95% confidence interval (CI) 0.57; 1.24], P = 0.38}. Ventricular pacing reduction modalities showed no significant differences in comparison to DDD for all-cause hospitalization or all-cause mortality [9 vs. 11%, OR 0.82 (95% CI 0.65; 1.03), P= 0.09; 6 vs. 6%, OR 0.97 (95% CI 0.74; 1.28), P = 0.84, respectively]. Novel VPRM measures effectively reduce VP in comparison to standard DDD. When actively programmed, VPRM did not improve clinical outcomes and were not superior to standard DDD programming in reducing incidence of PerAF, all-cause hospitalization, or all-cause mortality.

  13. Angiotensin-converting enzyme and matrix metalloproteinase inhibition with developing heart failure: comparative effects on left ventricular function and geometry

    NASA Technical Reports Server (NTRS)

    McElmurray, J. H. 3rd; Mukherjee, R.; New, R. B.; Sampson, A. C.; King, M. K.; Hendrick, J. W.; Goldberg, A.; Peterson, T. J.; Hallak, H.; Zile, M. R.; hide

    1999-01-01

    The progression of congestive heart failure (CHF) is left ventricular (LV) myocardial remodeling. The matrix metalloproteinases (MMPs) contribute to tissue remodeling and therefore MMP inhibition may serve as a useful therapeutic target in CHF. Angiotensin converting enzyme (ACE) inhibition favorably affects LV myocardial remodeling in CHF. This study examined the effects of specific MMP inhibition, ACE inhibition, and combined treatment on LV systolic and diastolic function in a model of CHF. Pigs were randomly assigned to five groups: 1) rapid atrial pacing (240 beats/min) for 3 weeks (n = 8); 2) ACE inhibition (fosinopril, 2.5 mg/kg b.i.d. orally) and rapid pacing (n = 8); 3) MMP inhibition (PD166793 2 mg/kg/day p.o.) and rapid pacing (n = 8); 4) combined ACE and MMP inhibition (2.5 mg/kg b.i.d. and 2 mg/kg/day, respectively) and rapid pacing (n = 8); and 5) controls (n = 9). LV peak wall stress increased by 2-fold with rapid pacing and was reduced in all treatment groups. LV fractional shortening fell by nearly 2-fold with rapid pacing and increased in all treatment groups. The circumferential fiber shortening-systolic stress relation was reduced with rapid pacing and increased in the ACE inhibition and combination groups. LV myocardial stiffness constant was unchanged in the rapid pacing group, increased nearly 2-fold in the MMP inhibition group, and was normalized in the ACE inhibition and combination treatment groups. Increased MMP activation contributes to the LV dilation and increased wall stress with pacing CHF and a contributory downstream mechanism of ACE inhibition is an effect on MMP activity.

  14. Correlation between the sudden jump-like increases of the atrio-Hisian interval induced during burst atrial pacing and during programmed atrial stimulation in patients with atrioventricular nodal reentrant tachycardia.

    PubMed

    Bayraktarova, Iskra H; Stoyanov, Milko K; Kunev, Boyan T; Shalganov, Tchavdar N

    To study the correlation between the sudden prolongations of the atrio-Hisian (AH) interval with ≥50 ms during burst and programmed atrial stimulation, and to define whether the AH jump during burst atrial pacing is a reliable diagnostic criterion for dual AV nodal physiology. Retrospective data on 304 patients with preliminary ECG diagnosis of AV nodal reentrant tachycardia (AVNRT), confirmed during electrophysiological study, was analyzed for the presence of AH jump during burst and programmed atrial stimulation, and for correlation between the pacing modes for inducing the jump. Wilcoxon signed-ranks test and Spearman's bivariate correlation coefficient were applied, significant was P-value <0.05. The population was aged 48.5 ± 15.7 (12-85) years; males were 38.5%. AH jump occurred during burst atrial pacing in 81% of the patients, and during programmed stimulation - in 78%, P = 0.366. In 63.2% AH jump was induced by both pacing modes; in 17.8% - only by burst pacing; in 14.8% - only by programmed pacing; in 4.2% there was no inducible jump. There was negative correlation between both pacing modes, ρ = -0.204, Р<0.001. Burst and programmed atrial stimulation separately prove the presence of dual AV nodal physiology in 81 and 78% of the patients with AVNRT, respectively. There is negative correlation between the two pacing modes, allowing the combination of the two methods to prove diagnostic in 95.8% of the patients. Copyright © 2017 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  15. DDD(R)-pacing, but not AAI(R)-pacing induces left ventricular desynchronization in patients with sick sinus syndrome: tissue-Doppler and 3D echocardiographic evaluation in a randomized controlled comparison.

    PubMed

    Albertsen, Andi Eie; Nielsen, Jens Cosedis; Poulsen, Steen Hvitfeldt; Mortensen, Peter Thomas; Pedersen, Anders Kirstein; Hansen, Peter Steen; Jensen, Henrik Kjaerulf; Egeblad, Henrik

    2008-02-01

    Increasing evidence from randomized trials and experimental studies indicates that right ventricular (RV) pacing may induce congestive heart failure. We studied regional left ventricular (LV) dyssynchrony and global LV function in 50 consecutive patients with sick sinus syndrome (SSS) randomized to either atrial pacing [AAI(R)] or dual chamber RV-pacing [DDD(R)]. Fifty consecutive patients were randomized to AAI(R) or DDD(R)-pacing. Tissue-Doppler imaging was used to quantify LV dyssynchrony in terms of number of segments with delayed longitudinal contraction (DLC). Left ventricular ejection fraction (LVEF) was measured using three-dimensional echocardiography. Dyssynchrony was more pronounced in the DDD(R)-group than in the AAI(R)-group at the 12 months follow-up (P < 0.05). This reflected a significant increase of dyssynchrony in the DDD(R)-group from baseline to the 12 months follow-up (1.3 +/- 1 to 2.1 +/- 1 segments displaying DLC per patient), P < 0.05. No change was observed in the AAI(R)-group (1.6 +/- 2 to 1.3 +/- 2 segments displaying DLC per patient, NS). No difference in LVEF, NYHA or NT-proBNP was observed between AAI(R)- and DDD(R)-mode after 12 months of pacing although LVEF decreased significantly in the DDD(R)-group from baseline (63.1 +/- 8%) to the 12 months follow-up (59.3 +/- 8%, P < 0.05), while LVEF remained unchanged in the AAI(R)-group (61.5 +/- 11% at baseline vs. 62.3 +/- 7% after 12 months, NS. In patients with SSS, DDD(R)-pacing but not AAI(R)-pacing induces significant LV desynchronization and reduction of LVEF.

  16. Comparison of right ventricular septal pacing and right ventricular apical pacing in patients receiving cardiac resynchronization therapy defibrillators: the SEPTAL CRT Study.

    PubMed

    Leclercq, Christophe; Sadoul, Nicolas; Mont, Lluis; Defaye, Pascal; Osca, Joaquim; Mouton, Elisabeth; Isnard, Richard; Habib, Gilbert; Zamorano, Jose; Derumeaux, Genevieve; Fernandez-Lozano, Ignacio

    2016-02-01

    Cardiac resynchronization therapy (CRT) is a recommended treatment of heart failure (HF) patients with depressed left ventricular ejection fraction and wide QRS. The optimal right ventricular (RV) lead position being a matter of debate, we sought to examine whether RV septal (RVS) pacing was not inferior to RV apical (RVA) pacing on left ventricular reverse remodelling in patients receiving a CRT-defibrillator. Patients (n = 263, age = 63.4 ± 9.5 years) were randomly assigned in a 1:1 ratio to RVS (n = 131) vs. RVA (n = 132) pacing. Left ventricular end-systolic volume (LVESV) reduction between baseline and 6 months was not different between the two groups (-25.3 ± 39.4 mL in RVS group vs. -29.3 ± 44.5 mL in RVA group, P = 0.79). Right ventricular septal pacing was not non-inferior (primary endpoint) to RVA pacing with regard to LVESV reduction (average difference = -4.06 mL; P = 0.006 with a -20 mL non-inferiority margin). The percentage of 'echo-responders' defined by LVESV reduction >15% between baseline and 6 months was similar in both groups (50%) with no difference in the time to first HF hospitalization or death (P = 0.532). Procedural or device-related serious adverse events occurred in 68 patients (RVS = 37) with no difference between the two groups (P = 0.401). This study demonstrates that septal RV pacing in CRT is non-inferior to apical RV pacing for LV reverse remodelling at 6 months with no difference in the clinical outcome. No recommendation for optimal RV lead position can hence be drawn from this study. NCT 00833352. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  17. Different regions of latest electrical activation during left bundle-branch block and right ventricular pacing in cardiac resynchronization therapy patients determined by coronary venous electro-anatomic mapping.

    PubMed

    Mafi Rad, Masih; Blaauw, Yuri; Dinh, Trang; Pison, Laurent; Crijns, Harry J; Prinzen, Frits W; Vernooy, Kevin

    2014-11-01

    Current targeted left ventricular (LV) lead placement strategy is directed at the latest activated region during intrinsic activation. However, cardiac resynchronization therapy (CRT) is most commonly applied by simultaneous LV and right ventricular (RV) pacing without contribution from intrinsic conduction. Therefore, targeting the LV lead to the latest activated region during RV pacing might be more appropriate. We investigated the difference in LV electrical activation sequence between left bundle-branch block (LBBB) and RV apex (RVA) pacing using coronary venous electro-anatomic mapping (EAM). Twenty consecutive CRT candidates with LBBB underwent intra-procedural coronary venous EAM during intrinsic activation and RVA pacing using EnSite NavX. Left ventricular lead placement was aimed at the latest activated region during LBBB according to current recommendations. In all patients, LBBB was associated with a circumferential LV activation pattern, whereas RVA pacing resulted in activation from the apex of the heart to the base. In 10 of 20 patients, RVA pacing shifted the latest activated region relative to LBBB. In 18 of 20 patients, the LV lead was successfully positioned in the latest activated region during LBBB. For the whole study population, LV lead electrical delay, expressed as percentage of QRS duration, was significantly shorter during RVA pacing than during LBBB (72 ± 13 vs. 82 ± 5%, P = 0.035). Right ventricular apex pacing alters LV electrical activation pattern in CRT patients with LBBB, and shifts the latest activated region in a significant proportion of these patients. These findings warrant reconsideration of the current practice of LV lead targeting for CRT. © 2014 The Authors. European Journal of Heart Failure © 2014 European Society of Cardiology.

  18. Kinetics of atrial repolarization alternans in a free-behaving ovine model.

    PubMed

    Jousset, Florian; Tenkorang, Joanna; Vesin, Jean-Marc; Pascale, Patrizio; Ruchat, Patrick; Rollin, Anne Garderes; Fromer, Martin; Narayan, Sanjiv M; Pruvot, Etienne

    2012-09-01

    Kinetics of Atrial Repolarization Alternans. Repolarization alternans (Re-ALT), a beat-to-beat alternation in action potential repolarization, promotes dispersion of repolarization, wavebreaks, and reentry. Recently, Re-ALT has been shown to play an important role in the transition from rapid pacing to atrial fibrillation (AF) in humans. The detailed kinetics of atrial Re-ALT, however, has not been reported so far. We developed a chronic free-behaving ovine pacing model to study the kinetics of atrial Re-ALT as a function of pacing rate. Thirteen sheep were chronically implanted with 2 pacemakers for the recording of broadband right atrial unipolar electrograms and delivery of rapid pacing protocols. Beat-to-beat differences in the atrial T-wave apex amplitude as a measure of Re-ALT and activation time were analyzed at incremental pacing rates until the effective refractory period (ERP) defined as stable 2:1 capture. Atrial Re-ALT appeared intermittently but without periodicity, and increased in amplitude as a function of pacing rate until ERP. Intermittent 2:1 atrial capture was observed at pacing cycle lengths 40 ms above ERP, and increased in duration as a function of pacing rate. Episodes of rapid pacing-induced AF were rare, and were preceded by Re-ALT or complex oscillations of atrial repolarization, but without intermittent capture. We show in vivo that atrial Re-ALT developed and increased in magnitude with rate until stable 2:1 capture. In rare instances where capture failure did not occur, Re-ALT and complex oscillations of repolarization surged and preceded AF initiation. (J Cardiovasc Electrophysiol, Vol. 23, pp. 1003-1012, September 2012). © 2012 Wiley Periodicals, Inc.

  19. Cardiac pacing for severe childhood neurally mediated syncope with reflex anoxic seizures

    PubMed Central

    McLeod, K; Wilson, N; Hewitt, J; Norrie, J; Stephenson, J

    1999-01-01

    OBJECTIVE—To determine whether permanent cardiac pacing could prevent syncope and seizures in children with frequent severe neurally mediated syncope, and if so whether dual chamber pacing was superior to single chamber ventricular pacing.
METHODS—Dual chamber pacemakers were implanted into 12 children (eight male, four female) aged 2-14 years (median 2.8 years) with frequent episodes of reflex anoxic seizures and a recorded prolonged asystole during an attack. The pacemaker was programmed to sensing only (ODO), single chamber ventricular pacing with hysteresis (VVI), and dual chamber pacing with rate drop response (DDD) for four month periods, with each patient allocated to one of the six possible sequences of these modes, according to chronological order of pacemaker implantation. The parent and patient were blinded to the pacemaker mode and asked to record all episodes of syncope or presyncope ("near miss" events). The doctor analysing the results was blinded to the patient and pacemaker mode.
RESULTS—One patient was withdrawn from the study after the pacemaker was removed because of infection. In the remaining children, both dual chamber and single chamber pacing significantly reduced the number of syncopal episodes compared with sensing only (p = 0.0078 for both). VVI was as effective as DDD for preventing syncope, but DDD was superior to VVI in reducing near miss events (p = 0.016).
CONCLUSIONS—Permanent pacing is an effective treatment for children with severe neurally mediated syncope and reflex anoxic seizures. VVI is as effective as DDD in preventing syncope and seizures, but DDD is superior in preventing overall symptoms.


Keywords: syncope; reflex anoxic seizures; pacing; paediatric cardiology PMID:10573501

  20. 77 FR 3958 - Mortgage Assets Affected by PACE Programs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-26

    ... of home improvement projects (e.g., home insulation, solar panels, geothermal energy units, etc... (``ANPR'') concerning mortgage assets affected by Property Assessed Clean Energy (``PACE'') programs and... February 28, 2011, that deal with property assessed clean energy (PACE) programs.'' In response to and...

  1. On the Effectiveness of a Neural Network for Adaptive External Pacing.

    ERIC Educational Resources Information Center

    Montazemi, Ali R.; Wang, Feng

    1995-01-01

    Proposes a neural network model for an intelligent tutoring system featuring adaptive external control of student pacing. An experiment was conducted, and students using adaptive external pacing experienced improved mastery learning and increased motivation for time management. Contains 66 references. (JKP)

  2. A self-paced brain-computer interface for controlling a robot simulator: an online event labelling paradigm and an extended Kalman filter based algorithm for online training.

    PubMed

    Tsui, Chun Sing Louis; Gan, John Q; Roberts, Stephen J

    2009-03-01

    Due to the non-stationarity of EEG signals, online training and adaptation are essential to EEG based brain-computer interface (BCI) systems. Self-paced BCIs offer more natural human-machine interaction than synchronous BCIs, but it is a great challenge to train and adapt a self-paced BCI online because the user's control intention and timing are usually unknown. This paper proposes a novel motor imagery based self-paced BCI paradigm for controlling a simulated robot in a specifically designed environment which is able to provide user's control intention and timing during online experiments, so that online training and adaptation of the motor imagery based self-paced BCI can be effectively investigated. We demonstrate the usefulness of the proposed paradigm with an extended Kalman filter based method to adapt the BCI classifier parameters, with experimental results of online self-paced BCI training with four subjects.

  3. Electrocardiograms with pacemakers: accuracy of computer reading.

    PubMed

    Guglin, Maya E; Datwani, Neeta

    2007-04-01

    We analyzed the accuracy with which a computer algorithm reads electrocardiograms (ECGs) with electronic pacemakers (PMs). Electrocardiograms were screened for the presence of electronic pacing spikes. Computer-derived interpretations were compared with cardiologists' readings. Computer-drawn interpretations required revision by cardiologists in 61.3% of cases. In 18.4% of cases, the ECG reading algorithm failed to recognize the presence of a PM. The misinterpretation of paced beats as intrinsic beats led to multiple secondary errors, including myocardial infarctions in varying localization. The most common error in computer reading was the failure to identify an underlying rhythm. This error caused frequent misidentification of the PM type, especially when the presence of normal sinus rhythm was not recognized in a tracing with a DDD PM tracking the atrial activity. The increasing number of pacing devices, and the resulting number of ECGs with pacing spikes, mandates the refining of ECG reading algorithms. Improvement is especially needed in the recognition of the underlying rhythm, pacing spikes, and mode of pacing.

  4. Pace of shifts in climate regions increases with global temperature

    NASA Astrophysics Data System (ADS)

    Mahlstein, Irina; Daniel, John S.; Solomon, Susan

    2013-08-01

    Human-induced climate change causes significant changes in local climates, which in turn lead to changes in regional climate zones. Large shifts in the world distribution of Köppen-Geiger climate classifications by the end of this century have been projected. However, only a few studies have analysed the pace of these shifts in climate zones, and none has analysed whether the pace itself changes with increasing global mean temperature. In this study, pace refers to the rate at which climate zones change as a function of amount of global warming. Here we show that present climate projections suggest that the pace of shifting climate zones increases approximately linearly with increasing global temperature. Using the RCP8.5 emissions pathway, the pace nearly doubles by the end of this century and about 20% of all land area undergoes a change in its original climate. This implies that species will have increasingly less time to adapt to Köppen zone changes in the future, which is expected to increase the risk of extinction.

  5. Impella™ Left Ventricular Assist Device for Acute Peripartum Cardiomyopathy After Cesarean Delivery.

    PubMed

    Padilla, Cesar; Hernandez Conte, Antonio; Ramzy, Danny; Sanchez, Michael; Zhao, Manxu; Park, Donald; Lubin, Lorraine

    2016-07-01

    Peripartum cardiomyopathy is a rare form of heart failure with significant perioperative implications. In this case report, we describe a 34-year-old gravida 5, parity 3, patient who was admitted for an elective cesarean delivery. During the delivery, the patient developed sudden cardiac arrest and was emergently intubated in the operating room. An emergent transesophageal echocardiogram revealed a left ventricular ejection fraction of 10% with global biventricular hypokinesis. Urgent multidisciplinary consultations led to the rapid implementation of the Impella™ 2.5 for ventricular support. The patient recovered ventricular function within 4 days and recovered to baseline function.

  6. A crisis of the heart: an acute reversible cardiomyopathy bridged to recovery in a patient with Addison's disease.

    PubMed

    Krishnamoorthy, Arun; Mentz, Robert J; Hyland, Kristen A; McMillan, Edward B; Patel, Chetan B; Milano, Carmelo A; Hernandez, Adrian F

    2013-01-01

    Primary adrenal insufficiency or Addison's disease is a rare disorder often difficult to diagnose on presentation by the nature of its associated nonspecific symptoms, such as nausea or weakness. Cardiovascular complications of the condition are usually limited to hypovolemic hypotension; however, we highlight here a rare, dramatic case of a fulminant adrenal crisis in a young man primarily marked by acute biventricular systolic failure and cardiogenic shock. The patient was successfully treated with corticosteroid replacement and bridged with temporary mechanical circulatory support to eventual complete the recovery of native myocardial function.

  7. In response to: Unsolved enigma of atrial myxoma with biventricular dysfunction.

    PubMed

    Dixit, Aanchal; Tewari, Prabhat; Soori, Rashmi; Agarwal, Surendra Kumar

    2018-01-01

    Thanks to Raut et al.[1] for appreciating our efforts in managing the case of biatrial myxomas. A brief discussion is warranted here on the types, size of cardiac myxomas, interleukin 6 (IL-6) levels, left ventricle (LV) dysfunction, and their relation. IL-6 is a pleiotropic cytokine with a variety of biologic activities, including differentiation of B cell, thymocytes, and T cells; activation of macrophages; and stimulation of hepatocyte to produce acute-phase proteins such as C-reactive protein.[2],[3] It is also said to have paracrine, endocrine, and autocrine growth functions.[3].

  8. Worldwide Experience with the Syncardia Total Artificial Heart in the Pediatric Population.

    PubMed

    Morales, David L S; Lorts, Angela; Rizwan, Raheel; Zafar, Farhan; Arabia, Francisco A; Villa, Chet R

    Individual centers have documented the use of the Syncardia Total Artificial Heart (TAH) in adolescents with heart failure; however, the number of patients at any given center is small. Herein, we describe the worldwide experience for all patients ≤21 years old supported with the TAH between May 2005 and May 2015 (n = 43). The number of patients experiencing a positive outcome at 60, 90, and 120 days were 30 (70%), 27 (63%), and 25 (58%), respectively. Successful bridge to transplantation varied by diagnosis, but outcomes reported are similar to adults supported with the TAH or biventricular assist devices.

  9. [Total artificial heart].

    PubMed

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  10. Adverse ventricular-ventricular interactions in right ventricular pressure load: Insights from pediatric pulmonary hypertension versus pulmonary stenosis.

    PubMed

    Driessen, Mieke M P; Hui, Wei; Bijnens, Bart H; Dragulescu, Andreea; Mertens, Luc; Meijboom, Folkert J; Friedberg, Mark K

    2016-06-01

    Right ventricular (RV) pressure overload has a vastly different clinical course in children with idiopathic pulmonary arterial hypertension (iPAH) than in children with pulmonary stenosis (PS). While RV function is well recognized as a key prognostic factor in iPAH, adverse ventricular-ventricular interactions and LV dysfunction are less well characterized and the pathophysiology is incompletely understood. We compared ventricular-ventricular interactions as hypothesized drivers of biventricular dysfunction in pediatric iPAH versus PS Eighteen iPAH, 16 PS patients and 18 age- and size-matched controls were retrospectively studied. Cardiac cycle events were measured by M-mode and Doppler echocardiography. Measurements were compared between groups using ANOVA with post hoc Dunnet's or ANCOVA including RV systolic pressure (RVSP; iPAH 96.8 ± 25.4 mmHg vs. PS 75.4 ± 18.9 mmHg; P = 0.011) as a covariate. RV-free wall thickening was prolonged in iPAH versus PS, extending beyond pulmonary valve closure (638 ± 76 msec vs. 562 ± 76 msec vs. 473 ± 59 msec controls). LV and RV isovolumetric relaxation were prolonged in iPAH (P < 0.001; LV 102.8 ± 24.1 msec vs. 63.1 ± 13.7 msec; RV 95 [61-165] vs. 28 [0-43]), associated with adverse septal kinetics; characterized by rightward displacement in early systole and leftward displacement in late RV systole (i.e., early LV diastole). Early LV diastolic filling was decreased in iPAH (73 ± 15.9 vs. PS 87.4 ± 14.4 vs. controls 95.8 ± 12.5 cm/sec; P = 0.004). Prolonged RVFW thickening, prolonged RVFW isovolumetric times, and profound septal dyskinesia are associated with interventricular mechanical discoordination and decreased early LV filling in pediatric iPAH much more than PS These adverse mechanics affect systolic and diastolic biventricular efficiency in iPAH and may form the basis for worse clinical outcomes. We used clinically derived data to study the pathophysiology of ventricular-ventricular interactions in right ventricular pressure overload, demonstrating distinct differences between pediatric pulmonary arterial hypertension (iPAH) and pulmonary stenosis (PS). Altered timing of right ventricular free wall contraction and profound septal dyskinesia are associated with interventricular mechanical discoordination and decreased early LV filling in iPAH much more than PS These adverse mechanics affect systolic and diastolic biventricular efficiency, independent of right ventricular systolic pressure. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  11. Cardiac optogenetic pacing in drosophila melanogaster using red-shifted opsins (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Electrical pacing is the current gold standard for investigation of mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, this method requires an invasive surgical procedure to implant the pacing electrodes. Recently, optogenetic pacing has been developed as an alternative, non-invasive method for heartbeat pacing in animals. It induces heartbeats by shining pulsed light on transgene-generated microbial opsins which in turn activate light gated ion channels in animal hearts. However, commonly used opsins, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we expressed recently engineered red-shifted opsins, ReaChR and CsChrimson, in the heart of a well-developed animal model, Drosophila melanogaster, for the first time. Optogenetic pacing was successfully conducted in both ReaChR and CsChrimson flies at their larval, pupal, and adult stages using 617 nm excitation light pulse, enabling a much deeper tissue penetration compared to blue stimulation light. A customized high speed and ultrahigh resolution OCM system was used to non-invasively monitor the heartbeat pacing in Drosophila. Compared to previous studies on optogenetic pacing of Drosophila, higher penetration depth of optogenetic excitation light was achieved in opaque late pupal flies. Lower stimulating power density is needed for excitation at each developmental stage of both groups, which improves the safety of this technique for heart rhythm studies.

  12. [The effect of atrial pacing on left ventricular diastolic function and BNP levels in patients with DDD pacemaker].

    PubMed

    Apali, Zeynep; Bayata, Serdar; Yeşil, Murat; Arikan, Erdinç; Postaci, Nursen

    2010-08-01

    We aimed to investigate the effect of atrial pacing on left ventricular diastolic function and brain natriuretic peptide (BNP) levels in patients with DDD pacemaker. Thirty patients with complete atrio-ventricular (AV) block and DDD pacemaker were included. All patients had normal left ventricular systolic function. Echocardiographic diastolic function parameters (transmitral and tissue Doppler velocities during early (E and E') and late (A and A') filling) and NT-pro-BNP levels were evaluated prospectively during atrial sensing and pacing periods. Echocardiographic data were compared with paired sample t test and NT-pro-BNP levels were compared with Wilcoxon test. Echocardiographic E/A, E'/A', E/E' ratios were calculated as 0.72+/-0.34, 0.61+/-0.21 and 8.76+/-2.58 during atrial sensing period. Same parameters were found as 0.71+/-0.23, 0.64+/-0.16 and 8.93+/-3.16 respectively during atrial pacing period. Echocardiographic left ventricular diastolic function parameters were not significantly different during atrial pacing and atrial sensing periods. Median plasma NT-pro-BNP levels were measured as 142 pg/ml (min-max 47-563 pg/ml) and 147 pg/ml (min-max 33-1035 pg/ml) during atrial sensing and pacing periods respectively. These levels were not significantly different (p=0.86). The result of this study has shown that, atrial pacing has not any additional detrimental effect on left ventricular diastolic function parameters in paced patients with normal left ventricular systolic function.

  13. 42 CFR 460.16 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false [Reserved] 460.16 Section 460.16 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  14. 42 CFR 460.66 - Training.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Training. 460.66 Section 460.66 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  15. 42 CFR 460.14 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false [Reserved] 460.14 Section 460.14 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  16. 42 CFR 460.16 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false [Reserved] 460.16 Section 460.16 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  17. 42 CFR 460.66 - Training.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Training. 460.66 Section 460.66 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  18. 42 CFR 460.14 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false [Reserved] 460.14 Section 460.14 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  19. 42 CFR 460.10 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Purpose. 460.10 Section 460.10 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  20. 42 CFR 460.10 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Purpose. 460.10 Section 460.10 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  1. The Student Experience of PACE at Macquarie University: Understanding Motivations for Learning

    ERIC Educational Resources Information Center

    McLachlan, Kath; Rawlings-Sanaei, Felicity; Mason, Colina; Haski-Levanthal, Debbie; Nabeel, Hussein

    2017-01-01

    Professional and Community Engagement (PACE) at Macquarie University offers undergraduate students experiential learning opportunities with local, regional and international partners. Through PACE, students work on mutually beneficial projects that both meet the partner's organizational goals and enable students to strengthen graduate capabilities…

  2. Self-Paced Economics Instruction: A Large-Scale Disaggregated Evaluation

    ERIC Educational Resources Information Center

    Soper, John C.; Thorton, Richard M.

    1976-01-01

    This paper reports on an evaluation of the Sterling Institute self-paced macroeconomics course at Northern Illinois University. Results show that a completely self-paced teaching format for macroeconomics is inferior to a well-directed, concept-oriented, graduate-student instructed, lecture-discussion taught course. (Author/RM)

  3. Web Tools: Keeping Learners on Pace

    ERIC Educational Resources Information Center

    Kosloski, Mickey

    2016-01-01

    One of the greatest challenges in teaching technology and engineering is pacing. Some students grasp new technological concepts quickly, while others need repetition and may struggle to keep pace. This poses an obstacle for the technology and engineering teacher, and is particularly true when teaching students to build a website. However, there…

  4. Achievement Monitoring of Individually Paced Instruction. Final Report.

    ERIC Educational Resources Information Center

    Pinsky, Paul D.

    A study was made to monitor achievement of individually paced instruction. The project concentrated on designing testing procedures in group paced instructional programs to provide information to student, teachers, parents and administrators which could be used in both a formative and summative evaluation. The three objectives of the project were:…

  5. A Meta-Analysis of Individualized Instruction in Dental Education.

    ERIC Educational Resources Information Center

    Dacanay, Lakshmi S; Cohen, Peter A.

    1992-01-01

    Meta-analysis of 34 comparative studies on conventional vs. individualized instruction (II) found most favored the latter but with small-moderate overall effect. Pacing had significant effect, with teacher-pacing more effective than student-paced learning. On average, II required less time than conventional teaching. Additional research on this…

  6. 42 CFR 460.64 - Personnel qualifications for staff with direct participant contact.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Administrative Requirements § 460.64 Personnel... frail or elderly population; (4) Meet a standardized set of competencies for the specific position...

  7. 42 CFR 460.106 - Plan of care.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Plan of care. 460.106 Section 460.106 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE...

  8. 42 CFR 460.64 - Personnel qualifications for staff with direct participant contact.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF HEALTH AND HUMAN SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PACE Administrative Requirements § 460.64 Personnel... frail or elderly population; (4) Meet a standardized set of competencies for the specific position...

  9. A review of optical pacing with infrared light

    NASA Astrophysics Data System (ADS)

    Ford, S. M.; Watanabe, M.; Jenkins, M. W.

    2018-02-01

    Optical pacing (OP) uses pulsed infrared light to initiate heartbeats in electrically excitable cardiac tissues without employing exogenous agents. OP is an alternative approach to electrical pacing that may overcome some its disadvantages for some applications. In this review, we discuss the initial demonstrations, mechanisms, safety, advantages and applications of OP.

  10. 42 CFR 460.100 - Emergency care.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Emergency care. 460.100 Section 460.100 Public...) PACE Services § 460.100 Emergency care. (a) Written plan. A PACE organization must establish and maintain a written plan to handle emergency care. The plan must ensure that CMS, the State, and PACE...

  11. 42 CFR 460.100 - Emergency care.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Emergency care. 460.100 Section 460.100 Public...) PACE Services § 460.100 Emergency care. (a) Written plan. A PACE organization must establish and maintain a written plan to handle emergency care. The plan must ensure that CMS, the State, and PACE...

  12. 42 CFR 460.100 - Emergency care.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Emergency care. 460.100 Section 460.100 Public...) PACE Services § 460.100 Emergency care. (a) Written plan. A PACE organization must establish and maintain a written plan to handle emergency care. The plan must ensure that CMS, the State, and PACE...

  13. Pacing from the right ventricular septum: is there a danger to the coronary arteries?

    PubMed

    Teh, Andrew W; Medi, Caroline; Rosso, Raphael; Lee, Geoffrey; Gurvitch, Ronen; Mond, Harry G

    2009-07-01

    Pacing from right ventricular (RV) septal sites has been suggested as an alternative to RV apical pacing in an attempt to avoid long-term adverse consequences on left ventricular function. Concern has been raised as to the relationship of the left anterior descending coronary artery (LAD) to pacing leads in these positions. We retrospectively analyzed three cases in which patients with RV active-fixation leads in situ also had coronary angiography. Multiple fluoroscopic views were used to determine the relationship of the lead tip at various pacing sites to the coronary arteries. A lead placed on the anterior wall was in close proximity to the LAD, whereas septal and free wall positioning was not. Placement of RV active-fixation leads on the septum avoids potential coronary artery compromise.

  14. A self-paced motor imagery based brain-computer interface for robotic wheelchair control.

    PubMed

    Tsui, Chun Sing Louis; Gan, John Q; Hu, Huosheng

    2011-10-01

    This paper presents a simple self-paced motor imagery based brain-computer interface (BCI) to control a robotic wheelchair. An innovative control protocol is proposed to enable a 2-class self-paced BCI for wheelchair control, in which the user makes path planning and fully controls the wheelchair except for the automatic obstacle avoidance based on a laser range finder when necessary. In order for the users to train their motor imagery control online safely and easily, simulated robot navigation in a specially designed environment was developed. This allowed the users to practice motor imagery control with the core self-paced BCI system in a simulated scenario before controlling the wheelchair. The self-paced BCI can then be applied to control a real robotic wheelchair using a protocol similar to that controlling the simulated robot. Our emphasis is on allowing more potential users to use the BCI controlled wheelchair with minimal training; a simple 2-class self paced system is adequate with the novel control protocol, resulting in a better transition from offline training to online control. Experimental results have demonstrated the usefulness of the online practice under the simulated scenario, and the effectiveness of the proposed self-paced BCI for robotic wheelchair control.

  15. Did recent world record marathon runners employ optimal pacing strategies?

    PubMed

    Angus, Simon D

    2014-01-01

    We apply statistical analysis of high frequency (1 km) split data for the most recent two world-record marathon runs: Run 1 (2:03:59, 28 September 2008) and Run 2 (2:03:38, 25 September 2011). Based on studies in the endurance cycling literature, we develop two principles to approximate 'optimal' pacing in the field marathon. By utilising GPS and weather data, we test, and then de-trend, for each athlete's field response to gradient and headwind on course, recovering standardised proxies for power-based pacing traces. The resultant traces were analysed to ascertain if either runner followed optimal pacing principles; and characterise any deviations from optimality. Whereas gradient was insignificant, headwind was a significant factor in running speed variability for both runners, with Runner 2 targeting the (optimal) parallel variation principle, whilst Runner 1 did not. After adjusting for these responses, neither runner followed the (optimal) 'even' power pacing principle, with Runner 2's macro-pacing strategy fitting a sinusoidal oscillator with exponentially expanding envelope whilst Runner 1 followed a U-shaped, quadratic form. The study suggests that: (a) better pacing strategy could provide elite marathon runners with an economical pathway to significant performance improvements at world-record level; and (b) the data and analysis herein is consistent with a complex-adaptive model of power regulation.

  16. Effect of right ventricular pacing on cardiac apex rotation assessed by a gyroscopic sensor.

    PubMed

    Marcelli, Emanuela; Cercenelli, Laura; Parlapiano, Mario; Fumero, Roberto; Bagnoli, Paola; Costantino, Maria Laura; Plicchi, Gianni

    2007-01-01

    To quantify cardiac apex rotation (CAR), the authors recently proposed the use of a Coriolis force sensor (gyroscope) as an alternative to other complex techniques. The aim of this study was to evaluate the effects of right ventricular (RV) pacing on CAR. A sheep heart was initially paced from the right atrium to induce a normal activation sequence at a fixed heart rate (AAI mode) and then an atrioventricular pacing was performed (DOO mode, AV delay = 60 ms). A small gyroscope was epicardially glued on the cardiac apex to measure the angular velocity (Ang V). From AAI to DOO pacing mode, an increase (+9.2%, p < 0.05) of the maximum systolic twisting velocity (Ang VMAX) and a marked decrease (-19.9%, p < 0.05) of the maximum diastolic untwisting velocity (Ang VMIN) resulted. RV pacing had negligible effects (-3.1%, p = 0.09) on the maximum angle of CAR, obtained by integrating Ang V. The hemodynamic parameters of systolic (LVdP/dtMAX) and diastolic (LVdP/dtMIN) cardiac function showed slight variations (-3.8%, p < 0.05 and +3.9%, p < 0.05, respectively). Results suggest that cardiac dyssynchrony induced by RV pacing can alter the normal physiological ventricular twist patterns, particularly affecting diastolic untwisting velocity.

  17. Feasibility of Leadless Cardiac Pacing Using Injectable Magnetic Microparticles

    PubMed Central

    Rotenberg, Menahem Y.; Gabay, Hovav; Etzion, Yoram; Cohen, Smadar

    2016-01-01

    A noninvasive, effective approach for immediate and painless heart pacing would have invaluable implications in several clinical scenarios. Here we present a novel strategy that utilizes the well-known mechano-electric feedback of the heart to evoke cardiac pacing, while relying on magnetic microparticles as leadless mechanical stimulators. We demonstrate that after localizing intravenously-injected magnetic microparticles in the right ventricular cavity using an external electromagnet, the application of magnetic pulses generates mechanical stimulation that provokes ventricular overdrive pacing in the rat heart. This temporary pacing consistently managed to revert drug-induced bradycardia, but could only last up to several seconds in the rat model, most likely due to escape of the particles between the applied pulses using our current experimental setting. In a pig model with open chest, MEF-based pacing was induced by banging magnetic particles and has lasted for a longer time. Due to overheating of the electromagnet, we intentionally terminated the experiments after 2 min. Our results demonstrate for the first time the feasibility of external leadless temporary pacing, using injectable magnetic microparticles that are manipulated by an external electromagnet. This new approach can have important utilities in clinical settings in which immediate and painless control of cardiac rhythm is required. PMID:27091192

  18. Extending the use of the pacing pulmonary artery catheter for safe minimally invasive cardiac surgery.

    PubMed

    Levin, Ricardo; Leacche, Marzia; Petracek, Michael R; Deegan, Robert J; Eagle, Susan S; Thompson, Annemarie; Pretorius, Mias; Solenkova, Nataliya V; Umakanthan, Ramanan; Brewer, Zachary E; Byrne, John G

    2010-08-01

    In this study, the therapeutic use of pacing pulmonary artery catheters in association with minimally invasive cardiac surgery was evaluated. A retrospective study. A single institutional university hospital. Two hundred twenty-four consecutive patients undergoing minimally invasive cardiac surgery through a small (5-cm) right anterolateral thoracotomy using fibrillatory arrest without aortic cross-clamping. Two hundred eighteen patients underwent mitral valve surgery (97%) alone or in combination with other procedures. Six patients underwent other cardiac operations. In all patients, the pacing pulmonary artery catheter was used intraoperatively to induce ventricular fibrillation during the cooling period, and in the postoperative period it also was used in 37 (17%) patients who needed to be paced, mainly for bradyarrhythmias (51%). There were no complications related to the insertion of the catheters. Six (3%) patients experienced a loss of pacing capture, and 2 (1%) experienced another complication requiring the surgical removal of the catheter. Seven (3%) patients needed postoperative implantation of a permanent pacemaker. In combination with minimally invasive cardiac surgery, pacing pulmonary artery catheters were therapeutically useful to induce ventricular fibrillatory arrest intraoperatively and for obtaining pacing capability in the postoperative period. Their use was associated with a low number of complications. Copyright 2010 Elsevier Inc. All rights reserved.

  19. Transdiaphragmatic pressure in quadriplegic individuals ventilated by diaphragmatic pacemaker.

    PubMed Central

    Garrido-García, H.; Martín-Escribano, P.; Palomera-Frade, J.; Arroyo, O.; Alonso-Calderón, J. L.; Mazaira-Alvarez, J.

    1996-01-01

    BACKGROUND: Electrophrenic pacing can be used in the management of ventilatory failure in quadriplegic patients. A study was undertaken to determine the pattern of transdiaphragmatic pressure (PDI) during the conditioning phase of electrophrenic pacing to see if it had a possible role in optimising the process of conditioning. METHODS: The tidal volume (TV) and PDI were measured in a group of six quadriplegic patients commencing ventilation by low frequency pulse stimulation (7-10 Hz) and low respiratory rate stimulation (< 10 breaths/min). RESULTS: Tidal volume increased between baseline and month 1 (4.33 ml/kg, p < 0.001) and between months 1 and 2 (3.00 ml/kg, p < 0.05) and then stabilised. PDI was higher during bilateral diaphragmatic pacing (mean (SD) 1.73 (0.30) kPa) than with either left (1.15 (0.34) kPa) or right (0.86 (0.37) kPa) unilateral pacing. PDI varied throughout the observation period, probably by interaction between recovery of the diaphragmatic fibres and the pacing regimen. CONCLUSIONS: Patients with quadriplegia due to high spinal injury can be maintained with ventilation by continuous electrophrenic pacing. The control criteria used in this study for pacing were tidal volume and the patient's tolerance, and the PDI measurement did not contribute any additional information to help with managing the conditioning process. PMID:8733497

  20. Time-Resolved Transposon Insertion Sequencing Reveals Genome-Wide Fitness Dynamics during Infection.

    PubMed

    Yang, Guanhua; Billings, Gabriel; Hubbard, Troy P; Park, Joseph S; Yin Leung, Ka; Liu, Qin; Davis, Brigid M; Zhang, Yuanxing; Wang, Qiyao; Waldor, Matthew K

    2017-10-03

    Transposon insertion sequencing (TIS) is a powerful high-throughput genetic technique that is transforming functional genomics in prokaryotes, because it enables genome-wide mapping of the determinants of fitness. However, current approaches for analyzing TIS data assume that selective pressures are constant over time and thus do not yield information regarding changes in the genetic requirements for growth in dynamic environments (e.g., during infection). Here, we describe structured analysis of TIS data collected as a time series, termed pattern analysis of conditional essentiality (PACE). From a temporal series of TIS data, PACE derives a quantitative assessment of each mutant's fitness over the course of an experiment and identifies mutants with related fitness profiles. In so doing, PACE circumvents major limitations of existing methodologies, specifically the need for artificial effect size thresholds and enumeration of bacterial population expansion. We used PACE to analyze TIS samples of Edwardsiella piscicida (a fish pathogen) collected over a 2-week infection period from a natural host (the flatfish turbot). PACE uncovered more genes that affect E. piscicida 's fitness in vivo than were detected using a cutoff at a terminal sampling point, and it identified subpopulations of mutants with distinct fitness profiles, one of which informed the design of new live vaccine candidates. Overall, PACE enables efficient mining of time series TIS data and enhances the power and sensitivity of TIS-based analyses. IMPORTANCE Transposon insertion sequencing (TIS) enables genome-wide mapping of the genetic determinants of fitness, typically based on observations at a single sampling point. Here, we move beyond analysis of endpoint TIS data to create a framework for analysis of time series TIS data, termed pattern analysis of conditional essentiality (PACE). We applied PACE to identify genes that contribute to colonization of a natural host by the fish pathogen Edwardsiella piscicida. PACE uncovered more genes that affect E. piscicida 's fitness in vivo than were detected using a terminal sampling point, and its clustering of mutants with related fitness profiles informed design of new live vaccine candidates. PACE yields insights into patterns of fitness dynamics and circumvents major limitations of existing methodologies. Finally, the PACE method should be applicable to additional "omic" time series data, including screens based on clustered regularly interspaced short palindromic repeats with Cas9 (CRISPR/Cas9). Copyright © 2017 Yang et al.

  1. Effects of gastric pacing on gastric emptying and plasma motilin

    PubMed Central

    Yang, Min; Fang, Dian-Chun; Li, Qian-Wei; Sun, Nian-Xu; Long, Qing-Lin; Sui, Jian-Feng; Gan, Lu

    2004-01-01

    AIM: To investigate the effects of gastric pacing on gastric emptying and plasma motilin level in a canine model of gastric motility disorders and the correlation between gastric emptying and plasma motilin level. METHODS: Ten healthy Mongrel dogs were divided into: experimental group of six dogs and control group of four dogs. A model of gastric motility disorders was established in the experimental group undergone truncal vagotomy combined with injection of glucagon. Gastric half-emptying time (GEt1/2) was monitored with single photon emission computerized tomography (SPECT), and the half-solid test meal was labeled with an isotope 99mTc sulfur colloid. Plasma motilin concentration was measured with radioimmunoassay (RIA) kit. Surface gastric pacing at 1.1-1.2 times the intrinsic slow-wave frequency and a superimposed series of high frequency pulses (10-30 Hz) was performed for 45 min daily for a month in conscious dogs. RESULTS: After surgery, GEt1/2 in dogs undergone truncal vagotomy was increased significantly from 56.35 ± 2.99 min to 79.42 ± 1.91 min (P < 0.001), but surface gastric pacing markedly accelerated gastric emptying and significantly decreased GEt1/2 to 64.94 ± 1.75 min (P < 0.001) in animals undergone vagotomy. There was a significant increase of plasma level of motilin at the phase of IMCIII (interdigestive myoelectrical complex, IMCIII) in the dogs undergone bilateral truncal vagotomy (baseline vs vagotomy, 184.29 ± 9.81 pg/ml vs 242.09 ± 17.22 pg/ml; P < 0.01). But plasma motilin concentration (212.55 ± 11.20 pg/ml; P < 0.02) was decreased significantly after a long-term treatment with gastric pacing. Before gastric pacing, GEt1/2 and plasma motilin concentration of the dogs undergone vagotomy showed a positive correlation (r = 0.867, P < 0.01), but after a long-term gastric pacing, GEt1/2 and motilin level showed a negative correlation (r = -0.733, P < 0.04). CONCLUSION: Surface gastric pacing with optimal pacing parameters can improve gastric emptying parameters and significantly accelerate gastric emptying and can resume or alter motor function in a canine model of motility disorders. Gastric emptying is correlated well with plasma motilin level before and after pacing, which suggests that motilin can modulate the mechanism of gastric pacing by altering gastric motility. PMID:14760770

  2. Study protocol for improving asthma outcomes through cross-cultural communication training for physicians: a randomized trial of physician training.

    PubMed

    Patel, Minal R; Thomas, Lara J; Hafeez, Kausar; Shankin, Matthew; Wilkin, Margaret; Brown, Randall W

    2014-06-16

    Massive resources are expended every year on cross-cultural communication training for physicians. Such training is a focus of continuing medical education nationwide and is part of the curriculum of virtually every medical school in America. There is a pressing need for evidence regarding the effects on patients of cross-cultural communication training for physicians. There is a need to understand the added benefit of such training compared to more general communication. We know of no rigorous study that has assessed whether cross-cultural communication training for physicians results in better health outcomes for their patients. The current study aims to answer this question by enhancing the Physician Asthma Care Education (PACE) program to cross cultural communication (PACE Plus), and comparing the effect of the enhanced program to PACE on the health outcomes of African American and Latino/Hispanic children with asthma. A three-arm randomized control trial is used to compare PACE Plus, PACE, and usual care. Both PACE and PACE Plus are delivered in two, two-hour sessions over a period of two weeks to 5-10 primary care physicians who treat African American and Latino/Hispanic children with asthma. One hundred twelve physicians and 1060 of their pediatric patients were recruited who self-identify as African American or Latino/Hispanic and experience persistent asthma. Physicians were randomized into receiving either the PACE Plus or PACE intervention or into the control group. The comparative effectiveness of PACE and PACE Plus on clinician's therapeutic and communication practices with the family/patient, children's urgent care use for asthma, asthma control, and quality of life, and parent/caretaker satisfaction with physician performance will be assessed. Data are collected via telephone survey and medical record review at baseline, 9 months following the intervention, and 21 months following the intervention. This study aims to reduce disparities in asthma outcomes among African American and Latino/Hispanic children through cross-cultural communication training of their physicians and assessing the added value of this training compared to general communication. The results of this study will provide important information about the value of cross-cultural training in helping to address persistent racial disparities in outcomes. ClinicalTrials.gov: NCT01251523 December 1, 2010.

  3. Progestin Concentrations Are Increased following Paced Mating in Midbrain, Hippocampus, Diencephalon, and Cortex of Rats in Behavioral Estrus, but Only in Midbrain of Diestrous Rats

    PubMed Central

    Frye, Cheryl A.; Rhodes, Madeline E.

    2013-01-01

    Background The progesterone (P4 ) metabolite, 5α-pregnan-3α-ol-20-one (3α,5α-THP), acts in the midbrain ventral tegmental area (VTA) to modulate the intensity and duration of lordosis. 3α,5α-THP can also have anti-anxiety and anti-stress effects in part through actions in the hippocampus. Separate reports indicate that manipulating 3α,5α-THP levels in the VTA or hippocampus respectively can influence lordosis and affective behavior. 3α,5α-THP levels can also be altered by behavioral experiences, such as mating or swim stress. Whether endogenous levels of 3α,5α-THP modulate and/or are increased in response to affective and/or reproductively-relevant behaviors was investigated. Methods In Experiment 1, rats in behavioral estrus or diestrus were individually tested sequentially in the open field, elevated plus maze, partner preference, social interaction, and paced mating tasks and levels of 17 β-estradiol (E2), P4, dihydroprogesterone (DHP), and 3α,5α-THP in serum, midbrain, hippocampus, diencephalon, and cortex were examined. In Experiments 2 and 3, rats in behavioral estrus or diestrus, were individually tested in the battery indicated above, with, or without, paced mating and tissues were collected immediately after testing for later assessment of endocrine measures. Results In Experiment 1, behavioral estrous, compared to diestrous, rats demonstrated more exploratory, anti-anxiety, social, and reproductive behaviors, and had higher levels of E2 and progestins in serum, midbrain, hippocampus, diencephalon, and cortex. In Experiment 2, in midbrain and hippocampus, levels of 3α,5α-THP and its precursor DHP were increased among rats in behavioral estrus that were mated. In diencephalon, and cortex, DHP levels were increased by mating. In Experiment 3, in midbrain, levels of 3α,5α-THP and its precursor DHP were increased among diestrous rats that were tested in the behavioral battery with mating as compared to those tested in the behavioral battery without mating. Conclusions Increased levels of 3α,5α-THP in behavioral estrus versus diestrous rats are associated with enhanced exploratory, anti-anxiety, social, and reproductive behaviors. Rats in behavioral estrus that are mated have further increases in 3α,5α-THP and/or DHP levels in midbrain, hippocampus, diencephalon, and cortex than do non-mated rats in behavioral estrus, whereas diestrous rats only show 3α,5α-THP increases in midbrain in response to behavioral testing that included mating. PMID:17028418

  4. Velocity distribution of women's 30-km cross-country skiing during Olympic Games from 2002-2014.

    PubMed

    Erdmann, Wlodzimierz S; Dancewicz-Nosko, Dorota; Giovanis, Vasilios

    2017-12-01

    Within several investigated endurance sport disciplines the distribution of load of the best competitors has a manner of evenly or slightly rising velocity values. Unfortunately many other competitors have usually diminishing values or when they are very poor they have evenly values. The aim of this study was to investigate distribution of velocity within 30-km cross-country female skiers. Cross-country skiing runs were investigated of Olympic Games 2002-2014 (Salt Lake City, Turin, Vancouver, Sochi). At every race two 15 km or three 10 km loops of the same vertical profile were taken into account. The competitors were divided onto: A - winners, B - medallists, C - competitors who obtained places 4 to 10 at the finish line (medium runners), D - competitors who obtained places 11 to 30 at the finish line (poor runners). Velocity data presented on the web pages of several institutions were utilized. The competitors had their velocity distributed in a manner with usually diminishing values. While comparing velocity of sequential loops with the mean velocity the difference for the poor runners reached the value of almost 6 %, which was too high. There was significant (usually negative) correlation coefficient between values of velocity deviation for the first and second loops and the mean value of velocity for the entire distance for the better runners and mixed, i.e. positive and negative values for the poorer runners. It was postulated investigations of velocity distribution should be introduced in coaching in order to inform competitors about their running. This advise is especially important for the poorer runners. Up to now cross country skiers run for themselves. It should be discussed whether the tactics used by road and track runners, i.e. running with pace makers, can be introduced in cross country skiing. Also the use of a drone during training can be used in order to maintain proper pace.

  5. Prevention of atrial fibrillation by inter-atrial septum pacing guided by electrophysiological testing, in patients with delayed interatrial conduction.

    PubMed

    Manolis, A G; Katsivas, A G; Vassilopoulos, C; Koutsogeorgis, D; Louvros, N E

    2002-04-01

    Interatrial septum (IAS) pacing seems efficient in synchronizing atrial depolarization in patients (pts) with delayed inter-atrial conduction, but its clinical role in preventing atrial tachyarrhythmias is still debated. This study was conducted in order to evaluate the clinical efficacy of IAS pacing guided by pace mapping of the IAS, as an alternative treatment modality in pts with drug refractory paroxysmal atrial fibrillation (PAF). We evaluated 29 pts (13 male, 16 female, 60 +/- 11 years), with drug refractory PAF, normal sinus node function and prolonged inter-atrial conduction time (P wave 142 +/- 10 ms). Multipolar catheters were inserted and the electrograms from the high right atrium (HRA) and proximal, middle and distal coronary sinus (CS) were recorded. The IAS was paced from multiple sites. The site of IAS where the timing between HRA and distal CS was <20 ms was considered the most suitable for synchronizing the atria. This site was found to be superior to the CS os. near the fossa ovalis in all pts. An active fixation atrial lead was positioned at this site and a standard lead was placed in the right ventricle. During IAS pacing, the P wave duration decreased significantly to 107 +/- 15 ms (P<0.001). At implant, the atrial sensing was 2.3 +/- 0.7 mV, the atrial pacing threshold was 0.95 +/- 0.15 V (0.5 ms) and the impedance was 760 +/- 80 Ohm. We evaluated the pts during four periods of 3 months duration each. The first period (control) was before pacemaker implantation, while the pts were under antiarrhythmic treatment. During the subsequent two periods, we evaluated the clinical efficacy of IAS pacing to prevent PAF recurrences, in AAT (75 bpm) and AAIR (75-140 bpm) mode, with random selection of the order and after discontinuation of antiarrhythmic treatment. During the fourth period, the same AAIR mode was assessed, but antiarrhythmic drugs were also administered. We compared the arrhythmia free interval among the four periods. The proportion of atrial paced beats in AAIR pacing mode plus antiarrhythmics was significantly higher compared with the drug-free period in AAIR mode (57 +/- 9% and 49 +/- 9% respectively, P=0017) and with AAT pacing mode (44 +/- 10%,(, P<0.001). In AAT mode, the arrhythmia free interval was 24.2 +/- 5.1 days, while it was 26.2 +/- 5.7 days in AAIR mode. These intervals did not differ significantly from the pre-implantation period (24.1 +/- 6.3 days). The arrhythmia free interval in AAIR pacing in combination with antiarrhythmic drug therapy was 38.7 +/- 8.1 days and this was significantly longer than the previous periods (P<0.05). Atrial septal pacing in combination with antiarrhythmic drug therapy reduced the incidence of PAF in pts with prolonged inter-atrial conduction times. Pace mapping of the IAS is an attractive technique to assess the shortest atrial activation time between HRA and distal CS. Whether placement of the atrial lead based on the shortest HRA--distal CS time is the best place in the IAS to prevent PAF still remains to be proven.

  6. PACE: Pharmacists use the power of communication in paediatric asthma.

    PubMed

    Elaro, Amanda; Shah, Smita; Pomare, Luca N; L Armour, Carol; Z Bosnic-Anticevich, Sinthia

    2014-10-01

    Paediatric asthma is a public health burden in Australia despite the availability of national asthma guidelines. Community pharmacy interventions focusing on paediatric asthma are scarce. Practitioner Asthma Communication and Education (PACE) is an evidence-based program, developed in the USA for general practice physicians, aimed at addressing the issues of poor clinician-patient communication in the management of paediatric asthma. This program has been shown to improve paediatric asthma management practices of general practitioners in the USA and Australia. The development of a PACE program for community pharmacists will fill a void in the current armamentarium for pharmacist-patient care. To adapt the educational program, PACE, to the community pharmacy setting. To test the feasibility of the new program for pharmacy and to explore its potential impact on pharmacists' communication skills and asthma related practices. Community pharmacies located within the Sydney metropolitan. The PACE framework was reviewed by the research team and amended in order to ensure its relevance within the pharmacy context, thereby developing PACE for Pharmacy. Forty-four pharmacists were recruited and trained in small groups in the PACE for Pharmacy workshops. Pharmacists' satisfaction and acceptability of the workshops, confidence in using communication strategies pre- and post-workshop and self-reported behaviour change post workshop were evaluated. Pharmacist self-reported changes in communication and teaching behaviours during a paediatric asthma consultation. All 44 pharmacists attended both workshops, completed pre- and post-workshop questionnaires and provided feedback on the workshops (100 % retention). The participants reported a high level of satisfaction and valued the interactive nature of the workshops. Following the PACE for Pharmacy program, pharmacists reported significantly higher levels in using the communication strategies, confidence in their application and their helpfulness. Pharmacists checked for written asthma self-management plan possession and inhaler device technique more regularly, and provided verbal instructions more frequently to paediatric asthma patients/carers at the initiation of a new medication. This study provides preliminary evidence that the PACE program can be translated into community pharmacy. PACE for Pharmacy positively affected self-reported communication and education behaviours of pharmacists. The high response rate shows that pharmacists are eager to expand on their clinical role in primary healthcare.

  7. Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents.

    PubMed

    O'Donnell, David; Sperzel, Johannes; Thibault, Bernard; Rinaldi, Christopher A; Pappone, Carlo; Gutleben, Klaus-Jürgen; Leclercq, Christopher; Razavi, Hedi; Ryu, Kyungmoo; Mcspadden, Luke C; Fischer, Avi; Tomassoni, Gery

    2017-04-01

    The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P < 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. Use of epicardial pacing wires after coronary artery bypass surgery.

    PubMed

    Sorensen, E R; Manna, D; McCourt, K

    1994-01-01

    To replicate a previous study that described the incidence and characteristics of patients after coronary artery bypass graft surgery who required the use of epicardial pacing wires and to explore the reasons for epicardial pacing wire use in this patient population. Ex post facto descriptive correlational. Cardiothoracic intensive care and step down units of a 500-bed medical center. Convenience sample of 196 patients after coronary artery bypass graft surgery, 165 who did not use the epicardial pacing wires and 31 who used the epicardial pacing wires to augment cardiac output, diagnose dysrhythmias, suppress dysrhythmias, or treat heart block. Patients receiving other surgical techniques in combination with coronary artery bypass graft surgery were not included. Recording of demographic and clinical data for all of the sample population, with additional data collected when the epicardial pacing wires were used. Independent t test and chi-square analysis were used to determine significance between the means and frequencies in the variables of the patients who used the epicardial pacing wires and those who did not. The significance level was set at 0.05. There were no statistically significant differences between the groups in terms of age or previous or recent myocardial infarction, which was opposite of the replicated study's findings. A statistically significant difference (p < 0.001) was found between the groups for the use of inotropic support, which was also opposite of the findings of that study. The group requiring epicardial pacing wire utilization demonstrated a greater need for diuretics in the preoperative phase than those who did not (p < 0.01), as well as a higher use of digitalis therapy before surgery (p < 0.01). Additionally, those who were paced experienced a greater cardiac output (p = 0.013) and cardiac index (p = 0.018) after pacing was initiated. The variation in findings between this study and the one replicated may be the result of variations in the patient populations, treatment practices, or preoperative condition. Replication of this study at a future date may reveal variables not identified here.

  9. Validation of electromechanical wave imaging in a canine model during pacing and sinus rhythm.

    PubMed

    Grondin, Julien; Costet, Alexandre; Bunting, Ethan; Gambhir, Alok; Garan, Hasan; Wan, Elaine; Konofagou, Elisa E

    2016-11-01

    Accurate determination of regional areas of arrhythmic triggers is of key interest to diagnose arrhythmias and optimize their treatment. Electromechanical wave imaging (EWI) is an ultrasound technique that can image the transient deformation in the myocardium after electrical activation and therefore has the potential to detect and characterize location of triggers of arrhythmias. The objectives of this study were to investigate the relationship between the electromechanical and the electrical activation of the left ventricular (LV) endocardial surface during epicardial and endocardial pacing and during sinus rhythm as well as to map the distribution of electromechanical delays. In this study, 6 canines were investigated. Two external electrodes were sutured onto the epicardial surface of the LV. A 64-electrode basket catheter was inserted through the apex of the LV. Ultrasound channel data were acquired at 2000 frames/s during epicardial and endocardial pacing and during sinus rhythm. Electromechanical and electrical activation maps were synchronously obtained from the ultrasound data and the basket catheter, respectively. The mean correlation coefficient between electromechanical and electrical activation was 0.81 for epicardial anterior pacing, 0.79 for epicardial lateral pacing, 0.69 for endocardial pacing, and 0.56 for sinus rhythm. The electromechanical activation sequence determined by EWI follows the electrical activation sequence and more specifically in the case of pacing. This finding is of key interest in the role that EWI can play in the detection of the anatomical source of arrhythmias and the planning of pacing therapies such as cardiovascular resynchronization therapy. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. Validation of Electromechanical Wave Imaging in a canine model during pacing and sinus rhythm

    PubMed Central

    Grondin, Julien; Costet, Alexandre; Bunting, Ethan; Gambhir, Alok; Garan, Hasan; Wan, Elaine; Konofagou, Elisa E.

    2016-01-01

    Background Accurate determination of regional areas of arrhythmic triggers is of key interest to diagnose arrhythmias and optimize their treatment. Electromechanical wave imaging (EWI) is an ultrasound technique that can image the transient deformation in the myocardium following electrical activation and therefore has the potential to detect and characterize location of triggers of arrhythmias. Objectives The objectives of this study are to investigate the relationship between electromechanical and electrical activation of the left-ventricular (LV) endocardial surface during epicardial and endocardial pacing as well as during sinus rhythm and also to investigate the distribution of electromechanical delays. Methods In this study, six canines were investigated. Two external electrodes were sutured onto the epicardial surface of the left ventricle (LV). A 64-electrode basket catheter was inserted through the apex of the LV. Ultrasound channel data were acquired at 2000 frames/s during epicardial and endocardial pacing as well as during sinus rhythm. Electromechanical and electrical activation maps were synchronously obtained from the ultrasound data and the basket catheter respectively. Results The mean correlation coefficient between electromechanical and electrical activation was R=0.81 for epicardial anterior pacing, R=0.79 for epicardial lateral pacing, R=0.69 for endocardial pacing and R=0.56 for sinus rhythm. Conclusions The electromechanical activation sequence determined by EWI follows the electrical activation sequence and more specifically in the case of pacing. This finding is of key interest in the role that EWI can play in the detection of the anatomical source of arrhythmias and the planning of pacing therapies such as cardiovascular resynchronization therapy. PMID:27498277

  11. Randomized, double-blind trial of simultaneous right and left atrial epicardial pacing for prevention of post-open heart surgery atrial fibrillation.

    PubMed

    Daoud, E G; Dabir, R; Archambeau, M; Morady, F; Strickberger, S A

    2000-08-15

    The purpose of this study was to assess simultaneous right and left atrial pacing as prophylaxis for postoperative atrial fibrillation. In a double-blind, randomized fashion, 118 patients who underwent open heart surgery were assigned to right atrial pacing at 45 bpm (RA-AAI; n=39), right atrial triggered pacing at a rate of >/=85 bpm (RA-AAT; n=38), or simultaneous right and left atrial triggered pacing at a rate of >/=85 bpm (Bi-AAT; n=41). Holter monitoring was performed for 4. 8+/-1.4 days after surgery to assess for episodes of atrial fibrillation lasting >5 minutes. The prevalence of postoperative atrial fibrillation was significantly less in the patients randomized to biatrial AAT pacing when compared with the other 2 pacing regimens (P=0.02). An episode of atrial fibrillation occurred in 4 (10%) of 41 patients in the Bi-AAT group compared with 11 (28%) of 39 patients in the RA-AAI group (P=0.03 versus Bi-AAT) and 12 (32%) of 38 patients in the RA-AAT group (P=0.01 versus Bi-AAT). There was no difference in the occurrence of atrial fibrillation between the right atrial AAI and AAT groups (P=0.8). There was no significant difference among the 3 groups with regard to the number of postoperative hospital days (7.3+/-4.2 days), morbidity (5.1%), or mortality rate (2.5%). Simultaneous right and left atrial triggered pacing is well tolerated and significantly reduces the prevalence of post-open heart surgery atrial fibrillation.

  12. Increased cardiac output elicits higher V̇O2max in response to self-paced exercise.

    PubMed

    Astorino, Todd Anthony; McMillan, David William; Edmunds, Ross Montgomery; Sanchez, Eduardo

    2015-03-01

    Recently, a self-paced protocol demonstrated higher maximal oxygen uptake versus the traditional ramp protocol. The primary aim of the current study was to further explore potential differences in maximal oxygen uptake between the ramp and self-paced protocols using simultaneous measurement of cardiac output. Active men and women of various fitness levels (N = 30, mean age = 26.0 ± 5.0 years) completed 3 graded exercise tests separated by a minimum of 48 h. Participants initially completed progressive ramp exercise to exhaustion to determine maximal oxygen uptake followed by a verification test to confirm maximal oxygen uptake attainment. Over the next 2 sessions, they performed a self-paced and an additional ramp protocol. During exercise, gas exchange data were obtained using indirect calorimetry, and thoracic impedance was utilized to estimate hemodynamic function (stroke volume and cardiac output). One-way ANOVA with repeated measures was used to determine differences in maximal oxygen uptake and cardiac output between ramp and self-paced testing. Results demonstrated lower (p < 0.001) maximal oxygen uptake via the ramp (47.2 ± 10.2 mL·kg(-1)·min(-1)) versus the self-paced (50.2 ± 9.6 mL·kg(-1)·min(-1)) protocol, with no interaction (p = 0.06) seen for fitness level. Maximal heart rate and cardiac output (p = 0.02) were higher in the self-paced protocol versus ramp exercise. In conclusion, data show that the traditional ramp protocol may underestimate maximal oxygen uptake compared with a newly developed self-paced protocol, with a greater cardiac output potentially responsible for this outcome.

  13. To pace or not to pace: a pilot study of four- and five-gaited Icelandic horses homozygous for the DMRT3 'Gait Keeper' mutation.

    PubMed

    Jäderkvist Fegraeus, K; Hirschberg, I; Árnason, T; Andersson, L; Velie, B D; Andersson, L S; Lindgren, G

    2017-12-01

    The Icelandic horse is a breed known mainly for its ability to perform the ambling four-beat gait 'tölt' and the lateral two-beat gait pace. The natural ability of the breed to perform these alternative gaits is highly desired by breeders. Therefore, the discovery that a nonsense mutation (C>A) in the DMRT3 gene was the main genetic factor for horses' ability to perform gaits in addition to walk, trot and canter was of great interest. Although several studies have demonstrated that homozygosity for the DMRT3 mutation is important for the ability to pace, only about 70% of the homozygous mutant (AA) Icelandic horses are reported to pace. The aim of the study was to genetically compare four- and five-gaited (i.e. horses with and without the ability to pace) AA Icelandic horses by performing a genome-wide association (GWA) analysis. All horses (n = 55) were genotyped on the 670K Axiom Equine Genotyping Array, and a GWA analysis was performed using the genabel package in r. No SNP demonstrated genome-wide significance, implying that the ability to pace goes beyond the presence of a single gene variant. Despite its limitations, the current study provides additional information regarding the genetic complexity of pacing ability in horses. However, to fully understand the genetic differences between four- and five-gaited AA horses, additional studies with larger sample materials and consistent phenotyping are needed. © 2017 Stichting International Foundation for Animal Genetics.

  14. Dual-dye optical mapping after myocardial infarction: does the site of ventricular stimulation alter the properties of electrical propagation?

    PubMed

    Saba, Samir; Mathier, Michael A; Mehdi, Haider; Liu, Tong; Choi, Bum-Rak; London, Barry; Salama, Guy

    2008-02-01

    Myocardial infarction (MI) disrupts electrical conduction in affected ventricular areas. We investigated the effect of MI on the regional voltage and calcium (Ca) signals and their propagation properties, with special attention to the effect of the site of ventricular pacing on these properties. New Zealand White rabbits were divided into four study groups: sham-operated (C, n = 6), MI with no pacing (MI, n = 7), MI with right ventricular pacing (MI + RV, n = 6), and MI with BIV pacing (MI + BIV, n = 7). At 4 weeks, hearts were excised, perfused, and optically mapped. As previously shown, systolic and diastolic dilation of the LV were prevented by BIV pacing, as was the reduction in LV fractional shortening. Four weeks after MI, optical mapping revealed markedly reduced action potential amplitudes and conduction velocities (CV) in MI zones, and these increased gradually in the border zone and normal myocardial areas. Also, Ca transients were absent in the infarcted areas and increased gradually 3-5 mm from the border of the normal zone. Neither BIV nor RV pacing affected these findings in any of the MI, border, or normal zones. MI has profound effects on the regional electrical and Ca signals and on their propagation properties in this rabbit model. The absence of differences in these parameters by study group suggests that altering the properties of myocardial electrical conduction and Ca signaling are unlikely mechanisms by which BIV pacing confers its benefits. Further studies into the regional, cellular, and molecular benefits of BIV pacing are therefore warranted.

  15. Influence of atrial substrate on local capture induced by rapid pacing of atrial fibrillation.

    PubMed

    Rusu, Alexandru; Jacquemet, Vincent; Vesin, Jean-Marc; Virag, Nathalie

    2014-05-01

    Preliminary studies showed that the septum area was the only location allowing local capture of both the atria during rapid pacing of atrial fibrillation (AF) from a single site. The present model-based study investigated the influence of atrial substrate on the ability to capture AF when pacing the septum. Three biophysical models of AF with an identical anatomy from human atria but with different AF substrates were used: (i) AF based on multiple wavelets, (ii) AF based on heterogeneities in vagal activation, (iii) AF based on heterogeneities in repolarization. A fourth anatomical model without Bachmann's bundle (BB) was also implemented. Rapid pacing was applied from the septum at pacing cycle lengths in the range of 50-100% of AF cycle length. Local capture was automatically assessed with 24 pairs of electrodes evenly distributed on the atrial surface. The results were averaged over 16 AF simulations. In the homogeneous substrate, AF capture could reach 80% of the atrial surface. Heterogeneities degraded the ability to capture during AF. In the vagal substrate, the capture tended to be more regular and the degradation of the capture was not directly related to the spatial extent of the heterogeneities. In the third substrate, heterogeneities induced wave anchorings and wavebreaks even in areas close to the pacing site, with a more dramatic effect on AF capture. Finally, BB did not significantly affect the ability to capture. Atrial fibrillation substrate had a significant effect on rapid pacing outcomes. The response to therapeutic pacing may therefore be specific to each patient.

  16. Difference Between Dormant Conduction Sites Revealed by Adenosine Triphosphate Provocation and Unipolar Pace-Capture Sites Along the Ablation Line After Pulmonary Vein Isolation.

    PubMed

    Kogawa, Rikitake; Okumura, Yasuo; Watanabe, Ichiro; Sonoda, Kazumasa; Sasaki, Naoko; Takahashi, Keiko; Iso, Kazuki; Nagashima, Koichi; Ohkubo, Kimie; Nakai, Toshiko; Kunimoto, Satoshi; Hirayama, Atsushi

    2016-01-01

    Dormant pulmonary vein (PV) conduction revealed by adenosine/adenosine triphosphate (ATP) provocation test and exit block to the left atrium by pacing from the PV side of the ablation line ("pace and ablate" method) are used to ensure durable pulmonary vein isolation (PVI). However, the mechanistic relation between ATP-provoked PV reconnection and the unexcitable gap along the ablation line is unclear.Forty-five patients with atrial fibrillation (AF) (paroxysmal: 31 patients, persistent: 14 patients; age: 61.1 ± 9.7 years) underwent extensive encircling PVI (EEPVI, 179 PVs). After completion of EEPVI, an ATP provocation test (30 mg, bolus injection) and unipolar pacing (output, 10 mA; pulse width, 2 ms) were performed along the previous EEPVI ablation line to identify excitable gaps. Dormant conduction was revealed in 29 (34 sites) of 179 PVs (16.2%) after EEP-VI (22/45 patients). Pace capture was revealed in 59 (89 sites) of 179 PVs (33.0%) after EEPVI (39/45 patients), and overlapping sites, ie, sites showing both dormant conduction and pace capture, were observed in 22 of 179 (12.3%) PVs (17/45 patients).Some of the ATP-provoked dormant PV reconnection sites were identical to the sites with excitable gaps revealed by pace capture, but most of the PV sites were differently distributed, suggesting that the main underling mechanism differs between these two forms of reconnection. These findings also suggest that performance of the ATP provocation test followed by the "pace and ablate" method can reduce the occurrence of chronic PV reconnections.

  17. Atrial septal pacing in small dogs: a pilot study.

    PubMed

    Jones, Ashley E; Estrada, Amara H; Pariaut, Romain; Sosa-Samper, Ivan; Shih, Andre C; Mincey, Brandy D; Moïse, N Sydney

    2014-09-01

    To determine the feasibility of atrial septal pacing via a delivery catheter-guided small non-retracting helix pacing lead. Six healthy beagles (8.3-12.9 kg). Using single plane fluoroscopic guidance, Medtronic(®) 3830 SelectSecure leads were connected to the atrial septum via Medtronic® Attain Select® II standard 90 Left Heart delivery catheter. Pacing threshold and lead impedance were measured at implantation. The Wenckebach point was tested via atrial pacing up to 220 paced pulses per minute (ppm). Thoracic radiographs were performed following implantation to identify the lead position, and repeated at 24 h, 1 month, and 3 months post-operatively. Macro-lead dislodgement occurred in two dogs at 24 h and in three dogs at one-month post-implantation. Lead impedance, measured at the time of implantation, ranged from 583 to 1421 Ω. The Wenckebach point was >220 ppm in four of the six dogs. The remaining two dogs had Wenckebach points of 120 and 190 ppm. This pilot study suggests the selected implantation technique and lead system were inadequate for secure placement in the atrial septum of these dogs. The possible reasons for inadequate stability include unsuitable lead design for this location, inadequate lead slack at the time of implantation and inadequate seating of the lead as evidenced by low impedance at the time of implantation. Other implantation techniques and/or pacing leads should be investigated to determine the optimal way of pacing the atria in small breed dogs that are prone to sinus node dysfunction. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Improving pacemaker therapy in congenital heart disease: contractility and resynchronization.

    PubMed

    Karpawich, Peter P

    2015-01-01

    Designed as effective therapy for patients with symptomatic bradycardia, implantable cardiac pacemakers initially served to improve symptoms and survival. With initial applications to the elderly and those with severe myocardial disease, extended longevity was not a major concern. However, with design technology advances in leads and generators since the 1980s, pacemaker therapy is now readily applicable to all age patients, including children with congenital heart defects. As a result, emphasis and clinical interests have advanced beyond simply quantity to quality of life. Adverse cardiac effects of pacing from right ventricular apical or epicardial sites with resultant left bundle branch QRS configurations have been recognized. As a result, and with the introduction of newer catheter-delivered pacing leads, more recent studies have focused on alternative or select pacing sites such as septal, outflow tract, and para-bundle of His. This is especially important in dealing with pacemaker therapy among younger patients and those with congenital heart disease, with expected decades of artificial cardiac stimulation, in which adverse myocellular changes secondary to pacing itself have been reported. As a correlate to these alternate or select pacing sites, applications of left ventricular pacing, either via the coronary sinus, intraseptal or epicardial, alone or in combination with right ventricular pacing, have gained interest for patients with heart failure. Although cardiac resynchronization pacing has, to date, had limited clinical applications among patients with congenital heart disease, the few published reports do indicate potential benefits as a bridge to cardiac transplant. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction

    PubMed Central

    Kim, Won Ho; Joung, Boyoung; Shim, Jaemin; Park, Jong Sung; Hwang, Eui-Seock; Pak, Hui-Nam; Kim, Sungsoon

    2010-01-01

    Purpose The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. Materials and Methods Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared. Results The baseline characteristics were comparable between the two groups, with a mean follow-up duration of 69 months. The incidence of death did not show statistical difference. However, the incidence of hospitalization for congestive heart failure (CHF) was significantly lower in the AAI(R) group (0%) than the DDD(R) group (8.8%, p = 0.03). Also, atrial fibrillation (AF) was found in 2.8% in the AAI(R) group, which was statistically different from 15.2% of patients in the DDD(R) group (p = 0.01). Four patients (5.5%) with AAI(R) developed AV block, and subsequently switched to DDD(R) pacing. The risk of AF was lower in the patients implanted with AAI(R) than those with DDD(R) [hazard ratio (HR), 0.84; 95% confidence interval, 0.72 to 0.97, p = 0.02]. Conclusion In patients with SND and intact AV conduction, AAI(R) pacing can achieve a better clinical outcome in terms of occurrence of CHF and AF than DDD(R) pacing. These findings support AAI(R) pacing as the preferred pacing mode in patients with SND and intact AV conduction. PMID:20879047

  20. Social Interaction in Self-Paced Distance Education

    ERIC Educational Resources Information Center

    Anderson, Terry; Upton, Lorne; Dron, Jon; Malone, Judi; Poelhuber, Bruno

    2015-01-01

    In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions…

  1. 42 CFR 423.4 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the term in § 422.2 of this chapter. MA-PD plan means an MA plan that provides qualified prescription... prescription drug plan, an MA-PD plan, a PACE Plan offering qualified prescription drug coverage, or a cost... PDP sponsor, MA organization offering a MA-PD plan, a PACE organization offering a PACE plan including...

  2. The Positive Alternative Credit Experience (PACE) Program a Quantitative Comparative Study

    ERIC Educational Resources Information Center

    Warren, Rebecca Anne

    2011-01-01

    The purpose of this quantitative comparative study was to evaluate the Positive Alternative Credit Experience (PACE) Program using an objectives-oriented approach to a formative program evaluation. The PACE Program was a semester-long high school alternative education program designed to serve students at-risk for academic failure or dropping out…

  3. PACE Instructor Guide. Level 1. Research & Development Series No. 240A.

    ERIC Educational Resources Information Center

    Ashmore, M. Catherine; Pritz, Sandra G.

    This teaching guide is designed for use in implementing the first level of a comprehensive entrepreneurship curriculum entitled: A Program for Acquiring Competence in Entrepreneurship (PACE). Designed for use with secondary students, the first level of PACE consists of 18 lessons that introduce students to the concepts involved in entrepreneurship…

  4. Application of PACE Principles for Population Health Management of Frail Older Adults.

    PubMed

    Stefanacci, Richard G; Reich, Shelley; Casiano, Alex

    2015-10-01

    To determine which practices would have the most impact on reducing hospital and emergency department admissions and nursing home placement among older adults with multiple comorbid conditions, a literature search and survey were conducted to identify and prioritize comprehensive care principles as practiced in the Program of All-inclusive Care for the Elderly (PACE). PACE medical directors and members of the PACE interdisciplinary team (IDT) were surveyed to gain their insights on the most impactful practices, which were identified as: End-of-Life Management, Caregiver Support, Management of Red Flags, Medication Management, Participant and Caregiver Health Care System Literacy, and Care Coordination. In addition, this research evaluated measures that could be used to assess an organization's level of success with regard to each of the 6 PACE practices identified. The results reported in this article, found through a survey with PACE medical directors and IDT members concerning effective interventions, can be viewed as strategies to improve care for older adults, enabling them to maintain their independence in the community, avoid the expense of facility-based care, and enhance their quality of life.

  5. The neural basis of audiomotor entrainment: an ALE meta-analysis

    PubMed Central

    Chauvigné, Léa A. S.; Gitau, Kevin M.; Brown, Steven

    2014-01-01

    Synchronization of body movement to an acoustic rhythm is a major form of entrainment, such as occurs in dance. This is exemplified in experimental studies of finger tapping. Entrainment to a beat is contrasted with movement that is internally driven and is therefore self-paced. In order to examine brain areas important for entrainment to an acoustic beat, we meta-analyzed the functional neuroimaging literature on finger tapping (43 studies) using activation likelihood estimation (ALE) meta-analysis with a focus on the contrast between externally-paced and self-paced tapping. The results demonstrated a dissociation between two subcortical systems involved in timing, namely the cerebellum and the basal ganglia. Externally-paced tapping highlighted the importance of the spinocerebellum, most especially the vermis, which was not activated at all by self-paced tapping. In contrast, the basal ganglia, including the putamen and globus pallidus, were active during both types of tapping, but preferentially during self-paced tapping. These results suggest a central role for the spinocerebellum in audiomotor entrainment. We conclude with a theoretical discussion about the various forms of entrainment in humans and other animals. PMID:25324765

  6. Acquired tricuspid valve stenosis due to intentionally redundant transvenous lead placement for VDD pacing in two small dogs.

    PubMed

    Gunther-Harrington, Catherine T; Michel, Adam O; Stern, Joshua A

    2015-12-01

    Placement of an endocardial VDD pacing lead in small dogs (<12 kg) may necessitate a redundant lead remaining looped in the right atrium for appropriate sensing and pacing. This report documented acquired tricuspid valve stenosis in two small dogs between 8 months and 4 years after VDD pacemaker placement for third-degree atrioventricular block. Echocardiography and Doppler echocardiography identified elevated transtricuspid flow velocities, prolonged pressure half-times, decreased valve leaflet excursions, and tricuspid regurgitation in both cases. Both cases were euthanized secondary to this pacing complication. Necropsy was performed in one case and confirmed adherence between the redundant lead loop, atrial and valve tissue. While VDD pacing in dogs has proven hemodynamic benefits, these benefits have not been demonstrated in terms of survival benefit or clinical signs. The requirement of redundant lead placement in small dogs for appropriate VDD lead function creates potential deleterious effects that should be weighed against the possible clinical value of VDD pacing in these patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Left heart pacing lead implantation using subxiphoid videopericardioscopy.

    PubMed

    Zenati, Marco A; Bonanomi, Gianluca; Chin, Albert K; Schwartzman, David

    2003-09-01

    Recent clinical data support the utility of left heart pacing. The transvenous approach for left heart pacing lead implantation is imperfect. A direct epicardial approach may have advantages, but heretofore its utility has been limited because of the requirement for thoracotomy. We sought to examine the feasibility of a method for epicardial lead implantation that did not require thoracotomy. In five large swine, percutaneous access to the epicardium was achieved with subxiphoid videopericardioscopy, using a device that marries endoscopy with a port through which pacing leads could be introduced. In each animal, standard, active fixation pacing leads were implanted onto the left atrium and ventricle. The atrial lead was implanted at the base of the appendage. The ventricular lead was implanted on the anterior, lateral, and inferior walls. Continuous direct visualization of the epicardium provided guidance for lead localization and fixation, including avoidance of complications such as trauma to epicardial coronary vessels. Capture thresholds were uniformly low. Postmortem examination demonstrated anatomically accurate, uncomplicated lead fixation. Using subxiphoid videopericardioscopy, uncomplicated, anatomically accurate left heart epicardial pacing lead implantation can be achieved without thoracotomy.

  8. Biventricular structural and functional responses to aortic constriction in a rabbit model of chronic right ventricular pressure overload.

    PubMed

    Apitz, Christian; Honjo, Osami; Humpl, Tilman; Li, Jing; Assad, Renato S; Cho, Mi Y; Hong, James; Friedberg, Mark K; Redington, Andrew N

    2012-12-01

    Chronic right ventricular (RV) pressure overload results in pathologic RV hypertrophy and diminished RV function. Although aortic constriction has been shown to improve systolic function in acute RV failure, its effect on RV responses to chronic pressure overload is unknown. Adjustable vascular banding devices were placed on the main pulmonary artery and descending aorta. In 5 animals (sham group), neither band was inflated. In 9 animals (PAB group), only the pulmonary arterial band was inflated, with adjustments on a weekly basis to generate systemic or suprasystemic RV pressure at 28 days. In 9 animals, both pulmonary arterial and aortic devices were inflated (PAB + AO group), the pulmonary arterial band as for the PAB group and the aortic band adjusted to increase proximal systolic blood pressure by approximately 20 mm Hg. Effects on the functional performance were assessed 5 weeks after surgery by conductance catheters, followed by histologic and molecular assessment. Contractile performance was significantly improved in the PAB + AO group versus the PAB group for both ventricles. Relative to sham-operated animals, both banding groups showed significant differences in myocardial histologic and molecular responses. Relative to the PAB group, the PAB + AO group showed significantly decreased RV cardiomyocyte diameter, decreased RV collagen content, and reduced RV expression of endothelin receptor type B, matrix metalloproteinase 9, and transforming growth factor β genes. Aortic constriction in an experimental model of chronic RV pressure overload not only resulted in improved biventricular systolic function but also improved myocardial remodeling. These data suggest that chronically increased left ventricular afterload leads to a more physiologically hypertrophic response in the pressure-overloaded RV. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  9. Right ventricular effects of intracoronary delivery of mesenchymal stem cells (MSC) in an animal model of pressure overload heart failure.

    PubMed

    Molina, Ezequiel J; Palma, Jon; Gupta, Dipin; Gaughan, John P; Houser, Steven; Macha, Mahender

    2009-12-01

    In a rat model of left ventricular pressure overload hypertrophy with biventricular failure, we studied the effects of intracoronary delivery of mesenchymal stem cells (MCS) upon right ventricular hemodynamic performance, profiles of local inflammation and apoptosis, and determinants of extracellular matrix remodeling. Sprague-Dawley rats underwent aortic banding and were followed by echocardiography. After a decrease in left ventricular fractional shortening of 25% from the baseline (relative 50% reduction), animals were randomized to an intracoronary injection of MSC (n=28) or PBS (n=20). Right ventricular hemodynamic assessment and measurement of local inflammatory markers, proapoptotic factors, and determinants of extracellular matrix remodeling were performed on post-transplantation day 7, 14, 21 or 28. MSC injection improved right ventricular systolic function in the MSC group compared to the control group (mean+/-SD, max dP/dt 772+/-272 mm Hg/s vs. 392+/-132 at 28 days, P<0.01). Diastolic function was similarly improved (mean+/-SD, max -dP/dt -558+/-171 mm Hg/s vs. -327+/-131 at 28 days, P<0.05). Right ventricular levels of IL-1, IL-6, TNF-alpha, bax, bak and p38 were significantly decreased in the MSC treated animals. Expression of MMP-3, MMP-6, MMP-9, TIMP-1 and TIMP-3 declined in the MSC group compared with controls after 28 days. In this model of left ventricular pressure overload hypertrophy and biventricular failure, intracoronary delivery of MSC was associated with an improvement in the right ventricular hemodynamic performance, profiles of local inflammation and apoptosis, and determinants of extracellular matrix remodeling.

  10. Cardiac Impairment Evaluated by Transesophageal Echocardiography and Invasive Measurements in Rats Undergoing Sinoaortic Denervation

    PubMed Central

    Sirvente, Raquel A.; Irigoyen, Maria C.; Souza, Leandro E.; Mostarda, Cristiano; La Fuente, Raquel N.; Candido, Georgia O.; Souza, Pamella R. M.; Medeiros, Alessandra; Mady, Charles; Salemi, Vera M. C.

    2014-01-01

    Background Sympathetic hyperactivity may be related to left ventricular (LV) dysfunction and baro- and chemoreflex impairment in hypertension. However, cardiac function, regarding the association of hypertension and baroreflex dysfunction, has not been previously evaluated by transesophageal echocardiography (TEE) using intracardiac echocardiographic catheter. Methods and Results We evaluated exercise tests, baroreflex sensitivity and cardiovascular autonomic control, cardiac function, and biventricular invasive pressures in rats 10 weeks after sinoaortic denervation (SAD). The rats (n = 32) were divided into 4 groups: 16 Wistar (W) with (n = 8) or without SAD (n = 8) and 16 spontaneously hypertensive rats (SHR) with (n = 8) or without SAD (SHRSAD) (n = 8). Blood pressure (BP) and heart rate (HR) did not change between the groups with or without SAD; however, compared to W, SHR groups had higher BP levels and BP variability was increased. Exercise testing showed that SHR had better functional capacity compared to SAD and SHRSAD. Echocardiography showed left ventricular (LV) concentric hypertrophy; segmental systolic and diastolic biventricular dysfunction; indirect signals of pulmonary arterial hypertension, mostly evident in SHRSAD. The end-diastolic right ventricular (RV) pressure increased in all groups compared to W, and the end-diastolic LV pressure increased in SHR and SHRSAD groups compared to W, and in SHRSAD compared to SAD. Conclusions Our results suggest that baroreflex dysfunction impairs cardiac function, and increases pulmonary artery pressure, supporting a role for baroreflex dysfunction in the pathogenesis of hypertensive cardiac disease. Moreover, TEE is a useful and feasible noninvasive technique that allows the assessment of cardiac function, particularly RV indices in this model of cardiac disease. PMID:24828834

  11. A compliant, banded outflow cannula for decreased afterload sensitivity of rotary right ventricular assist devices.

    PubMed

    Gregory, Shaun D; Schummy, Emma; Pearcy, Mark; Pauls, Jo P; Tansley, Geoff; Fraser, John F; Timms, Daniel

    2015-02-01

    Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm(5) until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm(5) ) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm(5) . Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Single-centre experience with the Thoratec paracorporeal ventricular assist device for patients with primary cardiac failure.

    PubMed

    Kirsch, Matthias; Vermes, Emmanuelle; Damy, Thibaud; Nakashima, Kuniki; Sénéchal, Mélanie; Boval, Bernadette; Drouet, Ludovic; Loisance, Daniel

    2009-01-01

    Temporary mechanical circulatory support may be indicated in some patients with cardiac failure refractory to conventional therapy, as a bridge to myocardial recovery or transplantation. To evaluate outcomes in cardiogenic shock patients managed by the primary use of a paracorporeal ventricular assist device (p-VAD). We did a retrospective analysis of demographics, clinical characteristics and survival of patients assisted with a Thoratec p-VAD. p-VADs were used in 84 patients with cardiogenic shock secondary to acute myocardial infarction (35%), idiopathic (31%) or ischaemic (12%) cardiomyopathy, myocarditis or other causes (23%). Before implantation, 23% had cardiac arrest, 38% were on a ventilator and 31% were on an intra-aortic balloon pump. Cardiac index was 1.6+/-0.5 L/min/m(2) and total bilirubin levels were 39+/-59 micromol/L. During support, 29 patients (35%) died in the intensive care unit and seven (10%) died after leaving. Forty-seven patients (56%) were weaned or transplanted, with one still under support. Despite significantly more advanced preoperative end-organ dysfunction, survival rates were similar in patients with biventricular devices (74%) and those undergoing isolated left ventricular support (24%) (63% versus 45%, respectively; p=0.2). Actuarial survival estimates after transplantation were 78.7+/-6.3%, 73.4+/-6.9% and 62.6+/-8.3% at 1, 3 and 5 years, respectively. Our experience validates the use of p-VAD as a primary device to support patients with cardiogenic shock. In contrast to short-term devices, p-VADs provide immediate ventricular unloading and pulsatile perfusion in a single procedure. Biventricular support should be used liberally in patients with end-organ dysfunction.

  13. Rotor Stability Separates Sustained Ventricular Fibrillation From Self-Terminating Episodes in Humans

    PubMed Central

    Krummen, David E.; Hayase, Justin; Morris, David J.; Ho, Jeffrey; Smetak, Miriam R.; Clopton, Paul; Rappel, Wouter-Jan; Narayan, Sanjiv M.

    2014-01-01

    Objective We mapped human ventricular fibrillation (VF) to define mechanistic differences between episodes requiring defibrillation versus those that spontaneously terminate. Background VF is a leading cause of mortality, yet episodes may also self-terminate. We hypothesized that the initial maintenance of human VF is dependent upon the formation and stability of VF rotors. Methods We enrolled 26 consecutive patients (age 64±10 years, n=13 with LV dysfunction) during ablation procedures for ventricular arrhythmias, using 64-electrode basket catheters in both ventricles to map VF prior to prompt defibrillation per IRB-approved protocol. Fifty-two inductions were attempted and 36 VF episodes were observed. Phase analysis was applied to identify bi-ventricular rotors in the first 10 seconds or until VF terminated, whichever came first (11.4±2.9 seconds to defibrillator charging). Results Rotors were present in 16 of 19 patients with VF, and in all patients with sustained VF. Sustained, but not self-limiting VF, was characterized by greater rotor stability: (1) rotors were present in 68±17% of cycles in sustained versus 11±18% of cycles in self-limiting VF (p<0.001); with (2) maximum continuous rotations greater in sustained (17±11, range 7–48) versus self-limiting VF (1.1±1.4, range 0–4, p<0.001). Additionally, biventricular rotor locations in sustained VF were conserved across multiple inductions (7/7 patients, p=0.025). Conclusions In patients with and without structural heart disease, the formation of stable rotors identifies individuals whose VF requires defibrillation from those in whom VF spontaneously self-terminates. Future work should define the mechanisms that stabilize rotors and evaluate whether rotor modulation may reduce subsequent VF risk. PMID:24794115

  14. Deferasirox, deferiprone and desferrioxamine treatment in thalassemia major patients: cardiac iron and function comparison determined by quantitative magnetic resonance imaging

    PubMed Central

    Pepe, Alessia; Meloni, Antonella; Capra, Marcello; Cianciulli, Paolo; Prossomariti, Luciano; Malaventura, Cristina; Putti, Maria Caterina; Lippi, Alma; Romeo, Maria Antonietta; Bisconte, Maria Grazia; Filosa, Aldo; Caruso, Vincenzo; Quarta, Antonella; Pitrolo, Lorella; Missere, Massimiliano; Midiri, Massimo; Rossi, Giuseppe; Positano, Vincenzo; Lombardi, Massimo; Maggio, Aurelio

    2011-01-01

    Background Oral deferiprone was suggested to be more effective than subcutaneous desferrioxamine for removing heart iron. Oral once-daily chelator deferasirox has recently been made commercially available but its long-term efficacy on cardiac iron and function has not yet been established. Our study aimed to compare the effectiveness of deferasirox, deferiprone and desferrioxamine on myocardial and liver iron concentrations and bi-ventricular function in thalassemia major patients by means of quantitative magnetic resonance imaging. Design and Methods From the first 550 thalassemia subjects enrolled in the Myocardial Iron Overload in Thalassemia network, we retrospectively selected thalassemia major patients who had been receiving one chelator alone for longer than one year. We identified three groups of patients: 24 treated with deferasirox, 42 treated with deferiprone and 89 treated with desferrioxamine. Myocardial iron concentrations were measured by T2* multislice multiecho technique. Biventricular function parameters were quantitatively evaluated by cine images. Liver iron concentrations were measured by T2* multiecho technique. Results The global heart T2* value was significantly higher in the deferiprone (34±11ms) than in the deferasirox (21±12 ms) and the desferrioxamine groups (27±11 ms) (P=0.0001). We found higher left ventricular ejection fractions in the deferiprone and the desferrioxamine versus the deferasirox group (P=0.010). Liver iron concentration, measured as T2* signal, was significantly lower in the desferrioxamine versus the deferiprone and the deferasirox group (P=0.004). Conclusions The cohort of patients treated with oral deferiprone showed less myocardial iron burden and better global systolic ventricular function compared to the patients treated with oral deferasirox or subcutaneous desferrioxamine. PMID:20884710

  15. Risk stratification in patients with advanced heart failure requiring biventricular assist device support as a bridge to cardiac transplantation.

    PubMed

    Cheng, Richard K; Deng, Mario C; Tseng, Chi-hong; Shemin, Richard J; Kubak, Bernard M; MacLellan, W Robb

    2012-08-01

    Prior studies have identified risk factors for survival in patients with end-stage heart failure (HF) requiring left ventricular assist device (LVAD) support. However, patients with biventricular HF may represent a unique cohort. We retrospectively evaluated a consecutive cohort of 113 adult, end-stage HF patients at University of California Los Angeles Medical Center who required BIVAD support between 2000 and 2009. Survival to transplant was 66.4%, with 1-year actuarial survival of 62.8%. All patients were Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Level 1 or 2 and received Thoratec (Pleasanton, CA) paracorporeal BIVAD as a bridge to transplant. Univariate analyses showed dialysis use, ventilator use, extracorporal membrane oxygenation use, low cardiac output, preserved LV ejection fraction (restrictive physiology), normal-to-high sodium, low platelet count, low total cholesterol, low high-density and high-density lipoprotein, low albumin, and elevated aspartate aminotransferase were associated with increased risk of death. We generated a scoring system for survival to transplant. Our final model, with age, sex, dialysis, cholesterol, ventilator, and albumin, gave a C-statistic of 0.870. A simplified system preserved a C-statistic of 0.844. Patients were divided into high-risk or highest-risk groups (median respective survival, 367 and 17 days), with strong discrimination between groups for death. We have generated a scoring system that offers high prognostic ability for patients requiring BIVAD support and hope that it may assist in clinical decision making. Further studies are needed to prospectively validate our scoring system. Copyright © 2012 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  16. Relationship Between Habitual Exercise and Performance on Cardiopulmonary Exercise Testing Differs Between Children With Single and Biventricular Circulations.

    PubMed

    O'Byrne, Michael L; Desai, Sanyukta; Lane, Megan; McBride, Michael; Paridon, Stephen; Goldmuntz, Elizabeth

    2017-03-01

    Increasing habitual exercise has been associated with improved cardiopulmonary exercise testing (CPET) performance, specifically maximal oxygen consumption in children with operatively corrected congenital heart disease. This has not been studied in children following Fontan palliation, a population in whom CPET performance is dramatically diminished. A single-center cross-sectional study with prospective and retrospective data collection was performed that assessed habitual exercise preceding a clinically indicated CPET in children and adolescents with Fontan palliation, transposition of the great arteries following arterial switch operation (TGA), and normal cardiac anatomy without prior operation. Data from contemporaneous clinical reports and imaging studies were collected. The association between percent predicted VO 2max and habitual exercise duration adjusted for known covariates was tested. A total of 175 subjects (75 post-Fontan, 20 with TGA, and 80 with normal cardiac anatomy) were enrolled. VO 2max was lower in the Fontan group than patients with normal cardiac anatomy (p < 0.0001) or TGA (p < 0.0001). In Fontan subjects, both univariate and multivariate analysis failed to demonstrate a significant association between habitual exercise and VO 2max (p = 0.6), in sharp contrast to cardiac normal subjects. In multivariate analysis, increasing age was the only independent risk factor associated with decreasing VO 2max in the Fontan group (p = 0.003). Habitual exercise was not associated with VO 2max in subjects with a Fontan as compared to biventricular circulation. Further research is necessary to understand why their habitual exercise is ineffective and/or what aspects of the Fontan circulation disrupt this association.

  17. Cerebral blood flow velocity and neurodevelopmental outcome in infants undergoing surgery for congenital heart disease.

    PubMed

    Cheng, Henry H; Wypij, David; Laussen, Peter C; Bellinger, David C; Stopp, Christian D; Soul, Janet S; Newburger, Jane W; Kussman, Barry D

    2014-07-01

    Cerebral blood flow velocity (CBFV) measured by transcranial Doppler sonography has provided information on cerebral perfusion in patients undergoing infant heart surgery, but no studies have reported a relationship to early postoperative and long-term neurodevelopmental outcomes. CBFV was measured in infants undergoing biventricular repair without aortic arch reconstruction as part of a trial of hemodilution during cardiopulmonary bypass (CPB); CBFV (Vm, mean; Vs, systolic; Vd, end-diastolic) in the middle cerebral artery and change in Vm (rVm) were measured intraoperatively and up to 18 hours post-CPB. Neurodevelopmental outcomes, measured at 1 year of age, included the psychomotor development index (PDI) and mental development index (MDI) of the Bayley Scales of Infant Development-II. CBFV was measured in 100 infants; 43 with D-transposition of the great arteries, 36 with tetralogy of Fallot, and 21 with ventricular septal defects. Lower Vm, Vs, Vd, and rVm at 18 hours post-CPB were independently related to longer intensive care unit duration of stay (p<0.05). In the 85 patients who returned for neurodevelopmental testing, lower Vm, Vs, Vd, and rVm at 18 hours post-CPB were independently associated with lower PDI (p<0.05) and MDI (p<0.05, except Vs: p=0.06) scores. Higher Vs and rVm at 18 hours post-CPB were independently associated with increased incidence of brain injury on magnetic resonance imaging in 39 patients. Postoperative CBFV after biventricular repair is related to early postoperative and neurodevelopmental outcomes at 1 year of age, possibly indicating that low CBFV is a marker of suboptimal postoperative hemodynamics and cerebral perfusion. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Cerebral Blood Flow Velocity and Neurodevelopmental Outcome in Infants Undergoing Surgery for Congenital Heart Disease

    PubMed Central

    Cheng, Henry H.; Wypij, David; Laussen, Peter C.; Bellinger, David C.; Stopp, Christian D.; Soul, Janet S.; Newburger, Jane W.; Kussman, Barry D.

    2014-01-01

    Background Cerebral blood flow velocity (CBFV) measured by transcranial Doppler sonography has provided information on cerebral perfusion in patients undergoing infant heart surgery, but no studies have reported a relationship to early postoperative and long-term neurodevelopmental outcomes. Methods CBFV was measured in infants undergoing biventricular repair without aortic arch reconstruction as part of a trial of hemodilution during cardiopulmonary bypass (CPB). CBFV (Vm, mean; Vs, systolic; Vd, end-diastolic) in the middle cerebral artery and change in Vm (rVm) were measured intraoperatively and up to 18 hours post-CPB. Neurodevelopmental outcomes, measured at 1 year of age, included the Psychomotor Development Index (PDI) and Mental Development Index (MDI) of the Bayley Scales of Infant Development-II. Results CBFV was measured in 100 infants: 43 with D-transposition of the great arteries, 36 with tetralogy of Fallot, and 21 with ventricular septal defects. Lower Vm, Vs, Vd, and rVm at18 hours post-CPB were independently related to longer ICU duration of stay (P<0.05). In the 85 patients who returned for neurodevelopmental testing, lower Vm, Vs, Vd and rVm at 18 hours post-CPB were independently associated with lower PDI (P<0.05) and MDI (P<0.05, except Vs: P=0.06) scores. Higher Vs and rVm at 18 hours post-CPB were independently associated with increased incidence of brain injury on MRI in 39 patients. Conclusions Postoperative CBFV after biventricular repair is related to early postoperative and neurodevelopmental outcomes at 1 year of age, possibly indicating that low CBFV is a marker of suboptimal postoperative hemodynamics and cerebral perfusion. PMID:24820395

  19. Outcomes of hospitalization in adults with Fontan palliation: The Mayo Clinic experience.

    PubMed

    Egbe, Alexander; Khan, Arooj R; Al-Otaibi, Mohamad; Said, Sameh M; Connolly, Heidi M

    2018-04-01

    The outcomes of hospitalization in the Fontan population have not been specifically studied. The purpose of this study was to describe outcomes of hospitalization (frequency and indications for hospitalization, and in-hospital mortality) in this population and to determine how these outcomes differ from those of other adults with congenital heart disease (CHD). This was a retrospective study of adult Fontan patients hospitalized at Mayo Clinic Rochester in 1990-2015. We selected age- and gender-matched control group of patients with repaired CHD and biventricular circulation hospitalized within the study period. A total of 367 Fontan patients (age 31±7 years and 259 [71%] with atriopulmonary Fontan) had 853 hospital admissions in 4 years (58 hospitalizations per 100 patient-years). The most common indications were arrhythmia (n=188, 22%), heart failure (n=169, 20%), and cardiac surgery (n=133, 16%). Overall in-hospital mortality was 4% (n=38), and the highest in-hospital mortality occurred in patients hospitalized for cardiac surgery (n=15, 11%) and heart failure (n=13, 8%). In comparison to the repaired CHD and biventricular circulation group, the Fontan group had more frequent hospitalizations (22 vs 58 per 100 patient-years, P<.001) and higher overall in-hospital mortality (1% vs 5%, P<.001), mortality after cardiac surgery (2% vs 11%, P=.01), and mortality for heart failure-related hospitalizations (2% vs 8%, P=.04). Adults with Fontan palliation had more frequent hospitalization and in-hospital mortality compared to the rest of the CHD population. Arrhythmia and heart failure were the most common indications for hospitalization. Perhaps optimal management of heart failure and arrhythmia may improve outcomes in this population. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Evidence Suggesting that the Cardiomyocyte Circadian Clock Modulates Responsiveness of the Heart to Hypertrophic Stimuli in Mice

    PubMed Central

    Durgan, David J.; Tsai, Ju-Yun; Grenett, Maximiliano H.; Pat, Betty M.; Ratcliffe, William F.; Villegas-Montoya, Carolina; Garvey, Merissa E.; Nagendran, Jeevan; Dyck, Jason R.B.; Bray, Molly S.; Gamble, Karen L.; Gimble, Jeffrey M.; Young, Martin E.

    2011-01-01

    Circadian dyssynchrony of an organism (at the whole body level) with its environment, either through light/dark cycle or genetic manipulation of clock genes, augments various cardiometabolic diseases. The cardiomyocyte circadian clock has recently been shown to influence multiple myocardial processes, ranging from transcriptional regulation and energy metabolism, to contractile function. We therefore reasoned that chronic dyssychrony of the cardiomyocyte circadian clock with its environment would precipitate myocardial maladaptation to a circadian challenge (simulated shift work; SSW). To test this hypothesis, 2 and 20 month old wild-type and CCM (Cardiomyocyte Clock Mutant; a model with genetic temporal suspension of the cardiomyocyte circadian clock at the active-to-sleep phase transition) mice were subjected to chronic (16-wks) bi-weekly 12-hr phase shifts in the light/dark cycle (i.e., SSW). Assessment of adaptation/maladaptation at whole body homeostatic, gravimetric, humoral, histological, transcriptional, and cardiac contractile function levels revealed essentially identical responses between wild-type and CCM littermates. However, CCM hearts exhibit increased bi-ventricular weight, cardiomyocyte size, and molecular markers of hypertrophy (anf, mcip1) independent of aging and/or SSW. Similarly, a second genetic model of selective temporal suspension of the cardiomyocyte circadian clock (Cardiomyocyte-specific BMAL1 Knockout [CBK] mice) exhibits increased bi-ventricular weight and mcip1 expression. Wild-type mice exhibit 5-fold greater cardiac hypertrophic growth (and 6-fold greater anf mRNA induction) when challenged with the hypertrophic agonist isoproterenol at the active-to-sleep phase transition, relative to isoproterenol administration at the sleep-to-active phase transition. This diurnal variation was absent in CCM mice. Collectively, these data suggest that the cardiomyocyte circadian clock likely influences responsiveness of the heart to hypertrophic stimuli. PMID:21452915

  1. Relationship between habitual exercise and performance on cardio-pulmonary exercise testing differs between children with single and bi-ventricular circulation

    PubMed Central

    O'Byrne, Michael L; Desai, Sanyukta; Lane, Megan; McBride, Michael; Paridon, Stephen; Goldmuntz, Elizabeth

    2016-01-01

    Background Increasing habitual exercise has been associated with improved cardiopulmonary exercise testing (CPET) performance, specifically maximal oxygen consumption in children with operatively corrected congenital heart disease. This has not been studied in children following Fontan palliation, a population in whom CPET performance is dramatically diminished. Methods A single-center cross-sectional study with prospective and retrospective data collection was performed that assessed habitual exercise preceding a clinically indicated CPET in children and adolescents with Fontan palliation, transposition of the great arteries following arterial switch operation (TGA), and normal cardiac anatomy without prior operation. Data from contemporaneous clinical reports and imaging studies were collected. The association between percent predicted VO2max and habitual exercise duration adjusted for known covariates was tested. Results A total of 175 subjects (75 post Fontan, 20 with TGA, and 80 with normal cardiac anatomy) were enrolled. VO2max was lower in the Fontan group than patients with normal cardiac anatomy (p<0.0001) or TGA (p<0.0001). In Fontan subjects, both univariate and multivariate analysis failed to demonstrate a significant association between habitual exercise and VO2max (p=0.6), in sharp contrast to cardiac normal subjects. In multivariate analysis, increasing age was the only independent risk factor associated with decreasing VO2max in the Fontan group (p=0.003). Discussion Habitual exercise was not associated with VO2max in subjects with a Fontan as compared to biventricular circulation. Further research is necessary to understand why their habitual exercise is ineffective and/or what aspects of the Fontan circulation disrupt this association. PMID:27878634

  2. Biventricular Heart Remodeling After Percutaneous or Surgical Pulmonary Valve Implantation: Evaluation by Cardiac Magnetic Resonance.

    PubMed

    Secchi, Francesco; Resta, Elda C; Cannaò, Paola M; Pluchinotta, Francesca; Piazza, Luciane; Butera, Gianfranco; Carminati, Mario; Sardanelli, Francesco

    2017-11-01

    The aim of this study was to evaluate the impact of percutaneous pulmonary valve implantation (PPVI) and surgical pulmonary valve replacement (SPVR) on biventricular and pulmonary valve function using cardiac magnetic resonance. Thirty-five patients aged 20±8 years (mean±SD) underwent PPVI, whereas 16 patients aged 30±11 years underwent SPVR. Cardiac magnetic resonance examinations were performed before and after the procedures with an average follow-up interval of 10 months. Cine steady-state free precession sequences for cardiac function and phase-contrast sequences for pulmonary flow were performed. The right ventricle (RV) and left ventricle (LV) functions were evaluated using a dedicated software. The RV end-diastolic volume index (mL/m) decreased significantly after PPVI and SPVR, from 74 to 64 (P=0.030) and from 137 to 83 (P=0.001), respectively. The RV ejection fraction increased significantly after SPVR, from 47% to 53% (P=0.038). The LV end-diastolic volume index increased significantly after PPVI, from 66 to 76 mL/m (P<0.001). The LV stroke volume index increased significantly after PPVI, from 34 to 43 mL/m (P=0.004). The analysis of bivariate correlations showed that in patients undergoing SPVR the RV changes after the procedure were positively correlated to LV changes in terms of end-systolic volume index (r=0587; P=0.017) and ejection fraction (r=0.681; P=0.004). A RV volumetric reduction and a positive effect on ventricular-ventricular interaction were observed after both PPVI and SPVR. After PPVI, a positive volumetric LV remodeling was found. No LV remodeling was found after SPVR. After both procedures, the replaced pulmonary valve functioned well.

  3. A bioprosthetic total artificial heart for end-stage heart failure: Results from a pilot study.

    PubMed

    Latrémouille, Christian; Carpentier, Alain; Leprince, Pascal; Roussel, Jean-Christian; Cholley, Bernard; Boissier, Elodie; Epailly, Eric; Capel, Antoine; Jansen, Piet; Smadja, David M

    2018-01-01

    The electro-hydraulically actuated Carmat total artificial heart (C-TAH) is designed to replace the heart in patients with end-stage heart failure, either as bridge to transplant or destination therapy. It provides pulsatile flow and contains bio-prosthetic blood contacting materials. A clinical feasibility study was conducted to evaluate the C-TAH safety and performance. Hospitalized patients, at imminent risk of death from irreversible biventricular failure despite optimal medical management, and not eligible for transplant or eligible but on extracorporeal life support, were enrolled. The primary endpoint was 30-days survival. Four patients were implanted with the C-TAH, three as destination therapy (ages 76, 68, 74) and one as bridge to transplant (age 58). They had implant times of 74, 270, 254 and 20 days respectively. All patients were free from hemolysis, clinical neurologic events, clinical evidence of thrombus and device-related infections. Hemodynamic and physical recovery allowed two patients to be discharged home for a cumulative duration of 7 months. The anticoagulation management strategy comprised initial unfractionated heparin, from postoperative day 2, followed by low molecular weight heparin and aspirin. An increased D-dimer level was observed in all patients during months 1 to 4. Temporary suspension of heparin anticoagulation resulted in thrombocytopenia and increased fibrin monomer, reversed by resuming anticoagulation with heparin. Causes of death were device-related (2 cases), respiratory failure and multi-organ failure. Preliminary clinical results with the C-TAH demonstrated good safety and performance profiles in patients suffering from biventricular failure, which need to be confirmed in a pivotal study. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  4. Conservation law for self-paced movements.

    PubMed

    Huh, Dongsung; Sejnowski, Terrence J

    2016-08-02

    Optimal control models of biological movements introduce external task factors to specify the pace of movements. Here, we present the dual to the principle of optimality based on a conserved quantity, called "drive," that represents the influence of internal motivation level on movement pace. Optimal control and drive conservation provide equivalent descriptions for the regularities observed within individual movements. For regularities across movements, drive conservation predicts a previously unidentified scaling law between the overall size and speed of various self-paced hand movements in the absence of any external tasks, which we confirmed with psychophysical experiments. Drive can be interpreted as a high-level control variable that sets the overall pace of movements and may be represented in the brain as the tonic levels of neuromodulators that control the level of internal motivation, thus providing insights into how internal states affect biological motor control.

  5. Acquired tricuspid valve stenosis associated with two ventricular endocardial pacing leads in a dog.

    PubMed

    Tompkins, Emily; Dulake, Michelle I; Ghaffari, Shadie; Nakamura, Reid K

    2015-01-01

    Acquired tricuspid valve stenosis (TVS) is a rare complication of endocardial pacing lead implantation in humans that has only been described once previously in the veterinary literature in a dog with excessive lead redundancy. A 12 yr old terrier presented with right-sided congestive heart failure 6 mo after implantation of a second ventricular endocardial pacing lead. The second lead was placed due to malfunction of the first lead, which demonstrated abnormally low impedance. Transthoracic echocardiography identified hyperechoic tissue associated with the pacing leads as they crossed the tricuspid valve annulus as well as a stenotic tricuspid inflow pattern via spectral Doppler interrogation. Medical management was ultimately unsuccessful and the dog was euthanized 6 wk after TVS was diagnosed. The authors report the first canine case of acquired TVS associated with two ventricular endocardial pacing leads.

  6. Ocean-atmosphere science from the NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission

    NASA Astrophysics Data System (ADS)

    Werdell, J.

    2016-12-01

    The new NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a strategic climate continuity activity that will not only extend key heritage ocean color, cloud, and aerosol data records, but also enable new insight into oceanographic and atmospheric responses to Earth's changing climate. The primary PACE instrument will be a spectroradiometer that spans the ultraviolet to shortwave infrared region at 5 nm resolution with a ground sample distance of 1 km at nadir. This payload will likely be complemented by a multi-angle polarimeter with a similar spectral range. Scheduled for launch in 2022, this PACE instrument pair will revolutionize studies of global biogeochemistry and carbon cycles in the ocean-atmosphere system. Here, I present a PACE mission overview, with focus on instrument characteristics, core and advanced data products, and overarching science objectives.

  7. How to Sync to the Beat of a Persistent Fractal Metronome without Falling Off the Treadmill?

    PubMed Central

    Roerdink, Melvyn; Daffertshofer, Andreas; Marmelat, Vivien; Beek, Peter J.

    2015-01-01

    In rehabilitation, rhythmic acoustic cues are often used to improve gait. However, stride-time fluctuations become anti-persistent with such pacing, thereby deviating from the characteristic persistent long-range correlations in stride times of self-paced walking healthy adults. Recent studies therefore experimented with metronomes with persistence in interbeat intervals and successfully evoked persistent stride-time fluctuations. The objective of this study was to examine how participants couple their gait to a persistent metronome, evoking persistently longer or shorter stride times over multiple consecutive strides, without wandering off the treadmill. Twelve healthy participants walked on a treadmill in self-paced, isochronously paced and non-isochronously paced conditions, the latter with anti-persistent, uncorrelated and persistent correlations in interbeat intervals. Stride-to-stride fluctuations of stride times, stride lengths and stride speeds were assessed with detrended fluctuation analysis, in conjunction with an examination of the coupling between stride times and stride lengths. Stride-speed fluctuations were anti-persistent for all conditions. Stride-time and stride-length fluctuations were persistent for self-paced walking and anti-persistent for isochronous pacing. Both stride times and stride lengths changed from anti-persistence to persistence over the four non-isochronous metronome conditions, accompanied by an increasingly stronger coupling between these gait parameters, with peak values for the persistent metronomes. These results revealed that participants were able to follow the beat of a persistent metronome without falling off the treadmill by strongly coupling stride-length fluctuations to the stride-time fluctuations elicited by persistent metronomes, so as to prevent large positional displacements along the treadmill. For self-paced walking, in contrast, this coupling was very weak. In combination, these results challenge the premise that persistent metronomes in gait rehabilitation would evoke stride-to-stride dynamics reminiscent of self-paced walking healthy adults. Future studies are recommended to include an analysis of the interrelation between stride times and stride lengths in addition to the correlational structure of either one in isolation. PMID:26230254

  8. How to Sync to the Beat of a Persistent Fractal Metronome without Falling Off the Treadmill?

    PubMed

    Roerdink, Melvyn; Daffertshofer, Andreas; Marmelat, Vivien; Beek, Peter J

    2015-01-01

    In rehabilitation, rhythmic acoustic cues are often used to improve gait. However, stride-time fluctuations become anti-persistent with such pacing, thereby deviating from the characteristic persistent long-range correlations in stride times of self-paced walking healthy adults. Recent studies therefore experimented with metronomes with persistence in interbeat intervals and successfully evoked persistent stride-time fluctuations. The objective of this study was to examine how participants couple their gait to a persistent metronome, evoking persistently longer or shorter stride times over multiple consecutive strides, without wandering off the treadmill. Twelve healthy participants walked on a treadmill in self-paced, isochronously paced and non-isochronously paced conditions, the latter with anti-persistent, uncorrelated and persistent correlations in interbeat intervals. Stride-to-stride fluctuations of stride times, stride lengths and stride speeds were assessed with detrended fluctuation analysis, in conjunction with an examination of the coupling between stride times and stride lengths. Stride-speed fluctuations were anti-persistent for all conditions. Stride-time and stride-length fluctuations were persistent for self-paced walking and anti-persistent for isochronous pacing. Both stride times and stride lengths changed from anti-persistence to persistence over the four non-isochronous metronome conditions, accompanied by an increasingly stronger coupling between these gait parameters, with peak values for the persistent metronomes. These results revealed that participants were able to follow the beat of a persistent metronome without falling off the treadmill by strongly coupling stride-length fluctuations to the stride-time fluctuations elicited by persistent metronomes, so as to prevent large positional displacements along the treadmill. For self-paced walking, in contrast, this coupling was very weak. In combination, these results challenge the premise that persistent metronomes in gait rehabilitation would evoke stride-to-stride dynamics reminiscent of self-paced walking healthy adults. Future studies are recommended to include an analysis of the interrelation between stride times and stride lengths in addition to the correlational structure of either one in isolation.

  9. Different horse's paces during hippotherapy on spatio-temporal parameters of gait in children with bilateral spastic cerebral palsy: A feasibility study.

    PubMed

    Antunes, Fabiane Nunes; Pinho, Alexandre Severo do; Kleiner, Ana Francisca Rozin; Salazar, Ana Paula; Eltz, Giovana Duarte; de Oliveira Junior, Alcyr Alves; Cechetti, Fernanda; Galli, Manuela; Pagnussat, Aline Souza

    2016-12-01

    Hippotherapy is often carried out for the rehabilitation of children with Cerebral Palsy (CP), with the horse riding at a walking pace. This study aimed to explore the immediate effects of a hippotherapy protocol using a walk-trot pace on spatio-temporal gait parameters and muscle tone in children with Bilateral Spastic CP (BS-CP). Ten children diagnosed with BS-CP and 10 healthy aged-matched children (reference group) took part in this study. The children with BS-CP underwent two sessions of hippotherapy for one week of washout between them. Two protocols (lasting 30min) were applied on separate days: Protocol 1: the horse's pace was a walking pace; and Protocol 2: the horse's pace was a walk-trot pace. Children from the reference group were not subjected to treatment. A wireless inertial measurement unit measured gait spatio-temporal parameters before and after each session. The Modified Ashworth Scale was applied for muscle tone measurement of hip adductors. The participants underwent the gait assessment on a path with surface irregularities (ecological context). The comparisons between BS-CP and the reference group found differences in all spatio-temporal parameters, except for gait velocity. Within-group analysis of children with BS-CP showed that the swing phase did not change after the walk pace and after the walk-trot pace. The percentage of rolling phase and double support improved after the walk-trot. The spasticity of the hip adductors was significantly reduced as an immediate result of both protocols, but this decrease was more evident after the walk-trot. The walk-trot protocol is feasible and is able to induce an immediate effect that improves the gait spatio-temporal parameters and the hip adductors spasticity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Can body surface microvolt T-wave alternans distinguish concordant and discordant intracardiac alternans?

    PubMed

    Floré, Vincent; Claus, Piet; Symons, Rolf; Smith, Godfrey L; Sipido, Karin R; Willems, Rik

    2013-08-01

    There is convincing experimental evidence that cellular action potential duration (APD) alternans is arrhythmogenic but its relationship with body surface microvolt T-wave alternans (MTWA) remains unclear. We investigated the relationship between MTWA and APD alternans induced by alternating cycle length (CL) pacing in a pig model. In 10 pigs, catheters in the right atrium (RA) and right (RV) and left ventricle (LV) allowed pacing and recording of monophasic action potentials (MAP). During RA pacing at stable 500-ms CL, LV was paced at alternating CL (505 ms and 495 ms). Changing the alternating LV (A-LV) pacing delay changes the size of the region with alternating ventricular activation. Spectral analysis of intracardiac MAP was correlated with body surface MTWA. In a similar setup (during alternating pacing in RV and LV), we investigated concordant versus discordant APD alternans. Pacing the LV with subtle alternating cycle lengths at short A-LV delay leads to broad QRS (97 ± 10 ms), body surface MTWA (mean Valt 4.2 ± 1.8 µV), and positive RR-interval alternans. At longer A-LV delay, not resulting in QRS widening (68 ± 5 ms), body surface RR alternans was absent but MTWA remained detectable and was even more pronounced (8.7 ± 5.1 µV, P < 0.01). During both concordant and discordant pacing MTWA was present. The precordial leads were better for detecting discordant APD alternans (8.0 ± 2.9 µV and 12.8 ± 4.52 µV, P = 0.02). MTWA is a potent technique to detect subtle and isolated intracardiac APD alternans that is artificially induced by alternating pacing. In the same model, discordant activation alternans can only be discriminated from concordant when using a quantifying approach of MTWA analysis. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  11. Ventilation patterns mimicking COPD in patients with diaphragmatic pacing for Ondine's curse. [/sup 133/Xe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makhija, M.C.; Bronfman, H.J.; Lange, R.C.

    1978-10-01

    Ventilation was studied with /sup 133/Xe in 18 patients with central hypoventilation (Ondine's Curse) in whom diaphragmatic pacers were implanted. Three distinct patterns emerged: Type I, improvement in ventilation on the paced side (11 of 18 patients); Type II, improvement on both the paced and unpaced side (4 of 18); and Type III, no improvement (3 of 18). With the pacer off, many of these patients have patterns that mimic chronic obstructive pulmonary disease and that revert to normal with pacing. This retention, clearly reversible, cannot reflect permanent airways or airspace disease.

  12. Sawtooth pacing by real-time auxiliary power control in a tokamak plasma.

    PubMed

    Goodman, T P; Felici, F; Sauter, O; Graves, J P

    2011-06-17

    In the standard scenario of tokamak plasma operation, sawtooth crashes are the main perturbations that can trigger performance-degrading, and potentially disruption-generating, neoclassical tearing modes. This Letter demonstrates sawtooth pacing by real-time control of the auxiliary power. It is shown that the sawtooth crash takes place in a reproducible manner shortly after the removal of that power, and this can be used to precisely prescribe, i.e., pace, the individual sawteeth. In combination with preemptive stabilization of the neoclassical tearing modes, sawtooth pacing provides a new sawtooth control paradigm for improved performance in burning plasmas.

  13. High frequency pacing of edge localized modes by injection of lithium granules in DIII-D H-mode discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bortolon, A.; Maingi, R.; Mansfield, D. K.

    A newly installed Lithium Granule Injector (LGI) was used to pace edge localized modes (ELM) in DIII-D. ELM pacing efficiency was studied injecting lithium granules of nominal diameter 0.3–0.9mm, speed of 50–120 m s -1 and average injection rates up to 100 Hz for 0.9mm granules and up to 700 Hz for 0.3mm granules. The efficiency of ELM triggering was found to depend strongly on size of the injected granules, with triggering efficiency close to 100% obtained with 0.9mm diameter granules, lower with smaller sizes, and weakly depending on granule velocity. Robust ELM pacing was demonstrated in ITER-like plasmas formore » the entire shot length, at ELM frequencies 3–5 times larger than the ‘natural’ ELM frequency observed in reference discharges. Within the range of ELM frequencies obtained, the peak ELM heat flux at the outer strike point was reduced with increasing pacing frequency. The peak heat flux reduction at the inner strike point appears to saturate at high pacing frequency. Lithium was found in the plasma core, with a concurrent reduction of metallic impurities and carbon. Altogether, high frequency ELM pacing using the lithium granule injection appears to be compatible with both H-mode energy confinement and attractive H-mode pedestal characteristics, but further assessment is need« less

  14. Optimal pacing strategy: from theoretical modelling to reality in 1500-m speed skating.

    PubMed

    Hettinga, F J; De Koning, J J; Schmidt, L J I; Wind, N A C; Macintosh, B R; Foster, C

    2011-01-01

    Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing profile. Seven national-level speed-skaters performed a SP 1500-m which was analysed by obtaining velocity (every 100 m) and body position (every 200 m) with video to calculate total mechanical power output. Together with gross efficiency and aerobic kinetics, obtained in separate trials, data were used to calculate aerobic and anaerobic power output profiles. An energy flow model was applied to SP, simulating a range of pacing strategies, and a theoretically optimal pacing profile was imposed in a second race (IM). Final time for IM was ∼2 s slower than SP. Total power distribution per lap differed, with a higher power over the first 300 m for IM (637.0 (49.4) vs 612.5 (50.0) W). Anaerobic parameters did not differ. The faster first lap resulted in a higher aerodynamic drag coefficient and perhaps a less effective push-off. Experienced athletes have a well-developed performance template, and changing pacing strategy towards a theoretically optimal fast start protocol had negative consequences on speed-skating technique and did not result in better performance.

  15. Will the Conscious-Subconscious Pacing Quagmire Help Elucidate the Mechanisms of Self-Paced Exercise? New Opportunities in Dual Process Theory and Process Tracing Methods.

    PubMed

    Micklewright, Dominic; Kegerreis, Sue; Raglin, John; Hettinga, Florentina

    2017-07-01

    The extent to which athletic pacing decisions are made consciously or subconsciously is a prevailing issue. In this article we discuss why the one-dimensional conscious-subconscious debate that has reigned in the pacing literature has suppressed our understanding of the multidimensional processes that occur in pacing decisions. How do we make our decisions in real-life competitive situations? What information do we use and how do we respond to opponents? These are questions that need to be explored and better understood, using smartly designed experiments. The paper provides clarity about key conscious, preconscious, subconscious and unconscious concepts, terms that have previously been used in conflicting and confusing ways. The potential of dual process theory in articulating multidimensional aspects of intuitive and deliberative decision-making processes is discussed in the context of athletic pacing along with associated process-tracing research methods. In attempting to refine pacing models and improve training strategies and psychological skills for athletes, the dual-process framework could be used to gain a clearer understanding of (1) the situational conditions for which either intuitive or deliberative decisions are optimal; (2) how intuitive and deliberative decisions are biased by things such as perception, emotion and experience; and (3) the underlying cognitive mechanisms such as memory, attention allocation, problem solving and hypothetical thought.

  16. The effect of hyperkalaemia on cardiac rhythm devices.

    PubMed

    Barold, S Serge; Herweg, Bengt

    2014-04-01

    In patients with pacemakers, hyperkalaemia causes three important abnormalities that usually become manifest when the K level exceeds 7 mEq/L: (i) widening of the paced QRS complex from delayed intraventricular conduction velocity, (ii) Increased atrial and ventricular pacing thresholds that may cause failure to capture. In this respect, the atria are more susceptible to loss of capture than the ventricles, and (iii) Increased latency (usually with ventricular pacing) manifested by a greater delay of the interval from the pacemaker stimulus to the onset of depolarization. First-degree ventricular pacemaker exit block may progress to second-degree Wenckebach (type I) exit block characterized by gradual prolongation of the interval from the pacemaker stimulus to the onset of the paced QRS complex ultimately resulting in an ineffectual stimulus. The disturbance may then progress to 2 : 1, 3 : 1 pacemaker exit block, etc., and eventually to complete exit block with total lack of capture. Ventricular undersensing is uncommonly observed because of frequent antibradycardia pacing. During managed ventricular pacing, hyperkalaemia-induced marked first-degree atrioventricular block may induce a pacemaker syndrome. With implantable cardioverter-defibrillators (ICDs) oversensing of the paced or spontaneous T-wave may occur. The latter may cause inappropriate shocks. A raised impedance from the right ventricular coil to the superior vena cava coil may become an important sign of hyperkalaemia in the asymptomatic or the minimally symptomatic ICD patient.

  17. High frequency pacing of edge localized modes by injection of lithium granules in DIII-D H-mode discharges

    DOE PAGES

    Bortolon, A.; Maingi, R.; Mansfield, D. K.; ...

    2016-04-08

    A newly installed Lithium Granule Injector (LGI) was used to pace edge localized modes (ELM) in DIII-D. ELM pacing efficiency was studied injecting lithium granules of nominal diameter 0.3–0.9mm, speed of 50–120 m s -1 and average injection rates up to 100 Hz for 0.9mm granules and up to 700 Hz for 0.3mm granules. The efficiency of ELM triggering was found to depend strongly on size of the injected granules, with triggering efficiency close to 100% obtained with 0.9mm diameter granules, lower with smaller sizes, and weakly depending on granule velocity. Robust ELM pacing was demonstrated in ITER-like plasmas formore » the entire shot length, at ELM frequencies 3–5 times larger than the ‘natural’ ELM frequency observed in reference discharges. Within the range of ELM frequencies obtained, the peak ELM heat flux at the outer strike point was reduced with increasing pacing frequency. The peak heat flux reduction at the inner strike point appears to saturate at high pacing frequency. Lithium was found in the plasma core, with a concurrent reduction of metallic impurities and carbon. Altogether, high frequency ELM pacing using the lithium granule injection appears to be compatible with both H-mode energy confinement and attractive H-mode pedestal characteristics, but further assessment is need« less

  18. PACE and the Federal Housing Finance Agency (FHFA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimring, Mark; Fuller, Merrian

    The FHFA regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On June 18, 2009, James B. Lockhart III, then Director of FHFA, released a letter expressing concern about the negative impact of energy loan tax assessment programs (ELTAPs) - also known as Property Assessed Clean Energy (PACE) programs - on both the housing finance system and homeowner program participants. Subsequently, a number of PACE proponents responded to the concerns laid out in the FHFA letter. In early Fall 2009, word circulated that FHFA was planning to follow its June letter withmore » guidance to other agencies, possibly including Fannie Mae and Freddie Mac, discouraging them from buying loans on properties subject to PACE-type assessment liens. This triggered a second round of stakeholder letters, several of which were addressed to President Obama. On October 18, 2009, the White House, in what some believe was an attempt to obviate the need for FHFA guidance, released a Policy Framework for PACE Financing Programs that outlined best practices guidance for homeowner and lender protection. As of February 2010, FHFA and the GSEs have agreed to monitor PACE programs and work with stakeholders and the Administration to consider additional guidance beyond the Policy Framework and to collect more information on PACE program efficacy and risks. A summary of the communications timeline and highlights of the communications are provided.« less

  19. Modeling Parenting Programs as an Interim Service for Families Waiting for Children's Mental Health Treatment.

    PubMed

    Cunningham, Charles E; Rimas, Heather; Chen, Yvonne; Deal, Ken; McGrath, Patrick; Lingley-Pottie, Patricia; Reid, Graham J; Lipman, Ellen; Corkum, Penny

    2015-01-01

    Using a discrete choice conjoint experiment, we explored the design of parenting programs as an interim strategy for families waiting for children's mental health treatment. Latent class analysis yielded 4 segments with different design preferences. Simulations predicted the Fast-Paced Personal Contact segment, 22.1% of the sample, would prefer weekly therapist-led parenting groups. The Moderate-Paced Personal Contact segment (24.7%) preferred twice-monthly therapist-led parenting groups with twice-monthly lessons. The Moderate-Paced E-Contact segment (36.3%), preferred weekly to twice-monthly contacts, e-mail networking, and a program combining therapist-led sessions with the support of a computerized telephone e-coach. The Slow-Paced E-Contact segment (16.9%) preferred an approach combining monthly therapist-led sessions, e-coaching, and e-mail networking with other parents. Simulations predicted 45.3% of parents would utilize an option combining 5 therapist coaching calls with 5 e-coaching calls, a model that could reduce costs and extend the availability of interim services. Although 41.0% preferred weekly pacing, 58% were predicted to choose an interim parenting service conducted at a twice-monthly to monthly pace. The results of this study suggest that developing interim services reflecting parental preferences requires a choice of formats that includes parenting groups, telephone-coached distance programs, and e-coaching options conducted at a flexible pace.

  20. Farewell to the Chairman - Marine Gen. Peter Pace

    Science.gov Websites

    oath of office from Marine Gen. Peter Pace, who retired after more than 40 years active duty military wife Lynne after giving the general his retirement certificate. Defense Dept. photo by Cherie A solutions, Marine Gen. Peter Pace said here today as he retired from the Marine Corps after more than 40

  1. Challenge of Engaging All Students via Self-Paced Interactive Electronic Learning Tutorials for Introductory Physics

    ERIC Educational Resources Information Center

    DeVore, Seth; Marshman, Emily; Singh, Chandralekha

    2017-01-01

    As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar…

  2. Interaction Equivalency in Self-Paced Online Learning Environments: An Exploration of Learner Preferences

    ERIC Educational Resources Information Center

    Rhode, Jason F.

    2009-01-01

    This mixed methods study explored the dynamics of interaction within a self-paced online learning environment. It used rich media and a mix of traditional and emerging asynchronous computer-mediated communication tools to determine what forms of interaction learners in a self-paced online course value most and what impact they perceive interaction…

  3. How Pacing of Multimedia Instructions Can Influence Modality Effects: A Case of Superiority of Visual Texts

    ERIC Educational Resources Information Center

    Stiller, Klaus D.; Freitag, Annika; Zinnbauer, Peter; Freitag, Christian

    2009-01-01

    "Present text accompanying pictures aurally to promote learning" is a well established principle of instructional design. But recently, it was shown that under certain conditions visual texts can be preferable. Instructional pacing seems to be one of these conditions that mediate effects. Especially, enabling learners to pace an…

  4. Meeting the Needs of Able Learners through Flexible Pacing. ERIC Digest #464.

    ERIC Educational Resources Information Center

    ERIC Clearinghouse on Handicapped and Gifted Children, Reston, VA.

    This information sheet, based on "Flexible Pacing for Able Learners" by Neil Daniel and June Cox, defines flexible pacing as any program in which students are taught material that is appropriately challenging for their ability and allows them to move forward in the curriculum as they master content and skill. The document outlines…

  5. Consistency of Students' Pace in Online Learning

    ERIC Educational Resources Information Center

    Hershkovitz, Arnon; Nachmias, Rafi

    2009-01-01

    The purpose of this study is to investigate the consistency of students' behavior regarding their pace of actions over sessions within an online course. Pace in a session is defined as the number of logged actions divided by session length (in minutes). Log files of 6,112 students were collected, and datasets were constructed for examining pace…

  6. Child and Parental Outcomes Following Involvement in a Preventive Intervention: Efficacy of the PACE Program

    ERIC Educational Resources Information Center

    Begle, Angela Moreland; Dumas, Jean E.

    2011-01-01

    This study evaluated whether engagement (i.e., attendance and quality of participation) in the Parenting our Children to Excellence (PACE) program predicted positive child and parent outcomes. PACE in an 8-week preventive intervention aimed at parents of preschool children. The study investigated the relation of engagement to outcomes in an…

  7. Development of a Student-Paced Course in General Pathology Utilizing a Computer Managed Evaluation System.

    ERIC Educational Resources Information Center

    Kent, Thomas H.; And Others

    The advantages, feasibility and problems associated with a student-paced course were investigated, and a computer managed evaluation system compared to paper and pencil testing mode. The development of a self-paced course was facilitated by explicit behavior objectives, a variety of learning materials referenced to the objectives and a large pool…

  8. Effect of "U-Pace" Instruction on Academic Success, Learning, and Perceptions in Younger and Older Undergraduates

    ERIC Educational Resources Information Center

    Fleming, Raymond; Barth, Dylan; Weber, Nicole; Pedrick, Laura E.; Kienzler, Sarah E.; Reddy, Diane M.

    2018-01-01

    A randomized controlled trial was conducted to determine the efficacy of "U-Pace" instruction for older undergraduates, ages 25 and older, and younger undergraduates, ages 18 to 24. Additionally, change in learner perceptions across the semester, an outcome not reported in the literature on "U-Pace" instruction, was…

  9. Keeping Pace with K-12 Online & Blended Learning: An Annual Review of Policy and Practice, 2013

    ERIC Educational Resources Information Center

    Watson, John; Murin, Amy; Vashaw, Lauren; Gemin, Butch; Rapp, Chris

    2013-01-01

    This is the 10th annual "Keeping Pace" report. "Keeping Pace" has several goals: (1) add to the body of knowledge about online education policy and practice, and make recommendations for advances; (2) serve as a reference source for information about programs and policies across the country, both for policymakers and…

  10. Processing Coordinate Subject-Verb Agreement in L1 and L2 Greek

    PubMed Central

    Kaltsa, Maria; Tsimpli, Ianthi M.; Marinis, Theodoros; Stavrou, Melita

    2016-01-01

    The present study examines the processing of subject-verb (SV) number agreement with coordinate subjects in pre-verbal and post-verbal positions in Greek. Greek is a language with morphological number marked on nominal and verbal elements. Coordinate SV agreement, however, is special in Greek as it is sensitive to the coordinate subject's position: when pre-verbal, the verb is marked for plural while when post-verbal the verb can be in the singular. We conducted two experiments, an acceptability judgment task with adult monolinguals as a pre-study (Experiment 1) and a self-paced reading task as the main study (Experiment 2) in order to obtain acceptance as well as processing data. Forty adult monolingual speakers of Greek participated in Experiment 1 and a hundred and forty one in Experiment 2. Seventy one children participated in Experiment 2: 30 Albanian-Greek sequential bilingual children and 41 Greek monolingual children aged 10–12 years. The adult data in Experiment 1 establish the difference in acceptability between singular VPs in SV and VS constructions reaffirming our hypothesis. Meanwhile, the adult data in Experiment 2 show that plural verbs accelerate processing regardless of subject position. The child online data show that sequential bilingual children have longer reading times (RTs) compared to the age-matched monolingual control group. However, both child groups follow a similar processing pattern in both pre-verbal and post-verbal constructions showing longer RTs immediately after a singular verb when the subject was pre-verbal indicating a grammaticality effect. In the post-verbal coordinate subject sentences, both child groups showed longer RTs on the first subject following the plural verb due to the temporary number mismatch between the verb and the first subject. This effect was resolved in monolingual children but was still present at the end of the sentence for bilingual children indicating difficulties to reanalyze and integrate information. Taken together, these findings demonstrate that (a) 10–12 year-old sequential bilingual children are sensitive to number agreement in SV coordinate constructions parsing sentences in the same way as monolingual children even though their vocabulary abilities are lower than that of age-matched monolingual peers and (b) bilinguals are slower in processing overall. PMID:27242577

  11. Pacing strategies during the swim, cycle and run disciplines of sprint, Olympic and half-Ironman triathlons.

    PubMed

    Wu, Sam Shi Xuan; Peiffer, Jeremiah J; Brisswalter, Jeanick; Nosaka, Kazunori; Lau, Wing Yin; Abbiss, Chris R

    2015-05-01

    This study investigated the influence of distance on self-selected pacing during the swim, cycle and run disciplines of sprint, Olympic and half-Ironman (HIM) distance triathlon races. Eight trained male triathletes performed the three individual races in <2 months. Participants' bikes were fitted with Schoberer Rad Meßtechnik to monitor speed, power output and heart rate during the cycle discipline. Global positioning system was worn to determine speed and heart rate during the swim and run disciplines. An even swim pacing strategy was adopted across all distances. A more stochastic pacing was observed during the HIM cycle [standard deviation of exposure variation analysis (EVASD) = 3.21 ± 0.61] when compared with the sprint cycle discipline (EVASD = 3.84 ± 0.44, p = 0.018). Only 20.9 ± 4.1 % of the cycling time was spent more than 10 % above the mean power output in the HIM, compared with 43.8 ± 2.9 % (p = 0.002) and 37.7 ± 11.1 % (p = 0.039) during the sprint and Olympic distance triathlons, respectively. Conversely, 13.6 ± 5.1 % of the cycling time was spent 5-10 % below the mean power output during the HIM, compared with 5.9 ± 1.2 % (p = 0.034) and 8.0 ± 5.1 % (p = 0.045) during the sprint and Olympic distance triathlons, respectively. A negative pacing strategy was adopted during the sprint distance run, compared with positive pacing strategy during the Olympic and HIM. Results of this study suggest that pacing strategies during triathlon are highly influenced by distance and discipline, and highlight the importance of developing pacing strategies based on distance, strengths and individual fitness.

  12. Extraction of SelectSecure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block.

    PubMed

    Shepherd, Emma; Stuart, Graham; Martin, Rob; Walsh, Mark A

    2015-06-01

    SelectSecure™ pacing leads (Medtronic Inc) are increasingly being used in pediatric patients and adults with structural congenital heart disease. The 4Fr lead is ideal for patients who may require lifelong pacing and can be advantageous for patients with complex anatomy. The purpose of this study was to compare the extraction of SelectSecure leads with conventional (stylette-driven) pacing leads in patients with structural congenital heart disease and congenital atrioventricular block. The data on lead extractions from pediatric and adult congenital heart disease (ACHD) patients from August 2004 to July 2014 at Bristol Royal Hospital for Children and the Bristol Heart Institute were reviewed. Multivariable regression analysis was used to determine whether conventional pacing leads were associated with a more difficult extraction process. A total of 57 patients underwent pacemaker lead extractions (22 SelectSecure, 35 conventional). No deaths occurred. Mean age at the time of extraction was 17.6 ± 10.5 years, mean weight was 47 ± 18 kg, and mean lead age was 5.6 ± 2.6 years (range 1-11 years). Complex extraction (partial extraction/femoral extraction) was more common in patients with conventional pacing leads at univariate (P < .01) and multivariate (P = .04) levels. Lead age was also a significant predictor of complex extraction (P < .01). SelectSecure leads can be successfully extracted using techniques that are used for conventional pacing leads. They are less likely to be partially extracted and are less likely to require extraction using a femoral approach compared with conventional pacing leads. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study.

    PubMed

    Ritter, Philippe; Duray, Gabor Z; Steinwender, Clemens; Soejima, Kyoko; Omar, Razali; Mont, Lluís; Boersma, Lucas V A; Knops, Reinoud E; Chinitz, Larry; Zhang, Shu; Narasimhan, Calambur; Hummel, John; Lloyd, Michael; Simmers, Timothy Alexander; Voigt, Andrew; Laager, Verla; Stromberg, Kurt; Bonner, Matthew D; Sheldon, Todd J; Reynolds, Dwight

    2015-10-01

    Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker. Patients having Class I or II indication for VVI pacing underwent implantation of a Micra transcatheter pacing system, from the femoral vein and fixated in the right ventricle using four protractible nitinol tines. Prespecified objectives were >85% freedom from unanticipated serious adverse device events (safety) and <2 V 3-month mean pacing capture threshold at 0.24 ms pulse width (efficacy). Patients were implanted (n = 140) from 23 centres in 11 countries (61% male, age 77.0 ± 10.2 years) for atrioventricular block (66%) or sinus node dysfunction (29%) indications. During mean follow-up of 1.9 ± 1.8 months, the safety endpoint was met with no unanticipated serious adverse device events. Thirty adverse events related to the system or procedure occurred, mostly due to transient dysrhythmias or femoral access complications. One pericardial effusion without tamponade occurred after 18 device deployments. In 60 patients followed to 3 months, mean pacing threshold was 0.51 ± 0.22 V, and no threshold was ≥2 V, meeting the efficacy endpoint (P < 0.001). Average R-wave was 16.1 ± 5.2 mV and impedance was 650.7 ± 130 ohms. Early assessment shows the transcatheter pacemaker can safely and effectively be applied. Long-term safety and benefit of the pacemaker will further be evaluated in the trial. ClinicalTrials.gov ID NCT02004873. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  14. The Longitudinal Study of Aging in Human Young Adults: Knowledge Gaps and Research Agenda.

    PubMed

    Moffitt, Terrie E; Belsky, Daniel W; Danese, Andrea; Poulton, Richie; Caspi, Avshalom

    2017-02-01

    To prevent onset of age-related diseases and physical and cognitive decline, interventions to slow human aging and extend health span must eventually be applied to people while they are still young and healthy. Yet most human aging research examines older adults, many with chronic disease, and little is known about aging in healthy young humans. This article explains how this knowledge gap is a barrier to extending health span and puts forward the case that geroscience should invest in researching the pace of aging in young adults. As one illustrative example, we describe an initial effort to study the pace of aging in a young-adult birth cohort by using repeated waves of biomarkers collected across the third and fourth decades to quantify the pace of coordinated physiological deterioration across multiple organ systems (eg, pulmonary, periodontal, cardiovascular, renal, hepatic, metabolic, and immune function). Findings provided proof of principle that it is possible to quantify individual variation in the pace of aging in young adults still free of age-related diseases. This article articulates research needs to improve longitudinal measurement of the pace of aging in young people, to pinpoint factors that slow or speed the pace of aging, to compare pace of aging against genomic clocks, to explain slow-aging young adults, and to apply pace of aging in preventive clinical trials of antiaging therapies. This article puts forward a research agenda to fill the knowledge gap concerning lifelong causes of aging. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Detecting Outliers in Marathon Data by Means of the Andrews Plot

    NASA Astrophysics Data System (ADS)

    Stehlík, Milan; Wald, Helmut; Bielik, Viktor; Petrovič, Juraj

    2011-09-01

    For an optimal race performance, it is important, that the runner keeps steady pace during most of the time of the competition. First time runners or athletes without many competitions often experience an "blow out" after a few kilometers of the race. This could happen, because of strong emotional experiences or low control of running intensity. Competition pace of half marathon of the middle level recreational athletes is approximately 10 sec quicker than their training pace. If an athlete runs the first third of race (7 km) at a pace that is 20 sec quicker than is his capacity (trainability), he would experience an "blow out" in the last third of the race. This would be reflected by reducing the running intensity and inability to keep steady pace in the last kilometers of the race and in the final time as well. In sports science, there are many diagnostic methods ([3], [2], [6]) that are used for prediction of optimal race pace tempo and final time. Otherwise there is lacking practical evidence of diagnostics methods and its use in the field (competition, race). One of the conditions that needs to be carried out is that athletes have not only similar final times, but it is important that they keep constant pace as much as possible during whole race. For this reason it is very important to find outliers. Our experimental group consisted of 20 recreational trained athletes (mean age 32,6 years±8,9). Before the race the athletes were instructed to run on the basis of their subjective feeling and previous experience. The data (running pace of each kilometer, average and maximal heart rate of each kilometer) were collected by GPS-enabled personal trainer Forerunner 305.

  16. Pacing-induced congenital heart defects assessed by OCT (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ford, Stephanie M.; McPheeters, Matt T.; Wang, Yves T.; Gu, Shi; Doughman, Yong Qiu; Strainic, James P.; Rollins, Andrew M.; Watanabe, Michiko; Jenkins, Michael W.

    2016-03-01

    The role of hemodynamics in early heart development is poorly understood. In order to successfully assess the impact of hemodynamics on development, we need to monitor and perturb blood flow, and quantify the resultant effects on morphology. Here, we have utilized cardiac optical pacing to create regurgitant flow in embryonic hearts and OCT to quantify regurgitation percentage and resultant morphology. Embryonic quail in a shell-less culture were optically paced at 3 Hz (well above the intrinsic rate or 1.33-1.67 Hz) on day 2 of development (3-4 weeks human) for 5 minutes. The pacing fatigued the heart and led to a prolonged period (> 1 hour) of increased regurgitant flow. Embryos were kept alive until day 3 (cardiac looping - 4-5 weeks human) or day 8 (4 chambered heart - 8 weeks human) to quantify resultant morphologic changes with OCT. All paced embryos imaged at day 3 displayed cardiac defects. The extent of regurgitant flow immediately after pacing was correlated with cardiac cushion size 24-hours post pacing (p-value < 0.01) with higher regurgitation leading to smaller cushions. Almost all embryos (16/18) surviving to day 8 exhibited congenital heart defects (CHDs) including 11/18 with valve defects, 5/18 with ventricular septal defects and 5/18 with hypoplastic right ventricles. Our data suggests that regurgitant flow leads to smaller cushions, which develop into abnormal valves and septa. Our model produces similar phenotypes as found in our fetal alcohol syndrome and velo-cardio-facial/DiGeorge syndrome models suggesting that hemodynamics plays a role in these syndromes as well. Utilizing OCT and optical pacing to understand hemodynamics in development is an important step towards determining CHD mechanisms and ultimately developing earlier treatments.

  17. Understanding pacing postconditioning-mediated cardiac protection: a role of oxidative stress and a synergistic effect of adenosine.

    PubMed

    Babiker, Fawzi A; Al-Jarallah, Aishah; Joseph, Shaji

    2017-05-01

    We and others have demonstrated a protective role for pacing postconditioning (PPC) against ischemia/reperfusion (I/R) injury in the heart; however, the underlying mechanisms behind these protective effects are not completely understood. In this study, we wanted to further characterize PPC-mediated cardiac protection, specifically identify optimal pacing sites; examine the role of oxidative stress; and test the existence of a potential synergistic effect between PPC and adenosine. Isolated rat hearts were subjected to coronary occlusion followed by reperfusion. PPC involved three, 30 s, episodes of alternating left ventricular (LV) and right atrial (RA) pacing. Multiple pacing protocols with different pacing electrode locations were used. To test the involvement of oxidative stress, target-specific agonists or antagonists were infused at the beginning of reperfusion. Hemodynamic data were digitally recorded, and cardiac enzymes, oxidant, and antioxidant status were chemically measured. Pacing at the LV or RV but not at the heart apex or base significantly (P < 0.001) protected against ischemia-reperfusion injury. PPC-mediated protection was completely abrogated in the presence of reactive oxygen species (ROS) scavenger, ebselen; peroxynitrite (ONOO - ) scavenger, uric acid; and nitric oxide synthase inhibitor, L-NAME. Nitric oxide (NO) donor, snap, however significantly (P < 0.05) protected the heart against I/R injury in the absence of PPC. The protective effects of PPC were significantly improved by adenosine. PPC-stimulated protection can be achieved by alternating LV and RA pacing applied at the beginning of reperfusion. NO, ROS, and the product of their interaction ONOO - play a significant role in PPC-induced cardiac protection. Finally, the protective effects of PPC can be synergized with adenosine.

  18. [The use of auto mode switching in patients with sick sinus syndrome].

    PubMed

    Vlasínová, J

    2005-01-01

    At present the dual chamber pacing, originally developed for patients with AV blockades, is widely used also for patients with Sick sinus syndrome (tachycardic-bradycardic type). But these patients often cause therapeutical problems to their physicians. In these cases either antiarrhythmic therapy is necessary to prevent recurrent supraventricular tachycardias (which are cause of rapid ventricular pacing) or in the case of failure of AA therapy the pacing mode has to be changed to DDI/R, which excludes physiological VAT pacing. The Auto Mode Switching (AMS) function ensures adequate ventricular pacing rate in the time of SV arrhythmias. Effects of dual chamber pacemakers equipped with AMS were studied in a group of patients with paroxysmal atrial fibrilation and/or atrial flutter. Therapy brings effects in lower of expenses due to less frequent visits at the physician, lower rate of rehospitalizations and lower need for powerful AA therapy.

  19. A Self-paced Course in Pharmaceutical Mathematics Using Web-based Databases

    PubMed Central

    Bourne, David W.A.; Davison, A. Machelle

    2006-01-01

    Objective To transform a pharmaceutical mathematics course to a self-paced instructional format using Web-accessed databases for student practice and examination preparation. Design The existing pharmaceutical mathematics course was modified from a lecture style with midsemester and final examinations to a self-paced format in which students had multiple opportunities to complete online, nongraded self-assessments as well as in-class module examinations. Assessment Grades and course evaluations were compared between students taking the class in lecture format with midsemester and final examinations and students taking the class in the self-paced instructional format. The number of times it took students to pass examinations was also analyzed. Conclusions Based on instructor assessment and student feedback, the course succeeded in giving students who were proficient in pharmaceutical mathematics a chance to progress quickly and students who were less skillful the opportunity to receive instruction at their own pace and develop mathematical competence. PMID:17149445

  20. The PACES Summer Science Trek: A Pre-College Science

    NASA Technical Reports Server (NTRS)

    Smith, Michelle B.

    1997-01-01

    The University of Texas at El Paso (UTEP) received five-year funding to form the Pan American Center for Earth and Environmental Studies (PACES) in July 1995. PACES has as its goals to conduct research contributing to NASA's Mission to Planet Earth and to develop skilled scientists and engineers. PACES seeks to gain a more comprehensive understanding of geological, ecological and environmental processes and changes taking place in the southwestern United States and northern Mexico region. The PACES center has collaborative ties with two NASA field center (Goddard Space Flight Center and Ames Research Center) and the Jet Propulsion Laboratory. The original proposal contained no provision for outreach programs. However, at a meeting in the fall of 1995, Dan Goldin, NASA Administrator, issued the challenge that in order to accomplish NASA's goals to educate more of the citizenry in science and engineering, the Centers should take a broader perspective aimed at younger children.

Top