Sample records for sequential injection chromatography

  1. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    ERIC Educational Resources Information Center

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  2. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    PubMed

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Sub-1min separation in sequential injection chromatography for determination of synthetic water-soluble dyes in pharmaceutical formulation.

    PubMed

    Davletbaeva, Polina; Chocholouš, Petr; Bulatov, Andrey; Šatínský, Dalibor; Solich, Petr

    2017-09-05

    Sequential Injection Chromatography (SIC) evolved from fast and automated non-separation Sequential Injection Analysis (SIA) into chromatographic separation method for multi-element analysis. However, the speed of the measurement (sample throughput) is due to chromatography significantly reduced. In this paper, a sub-1min separation using medium polar cyano monolithic column (5mm×4.6mm) resulted in fast and green separation with sample throughput comparable with non-separation flow methods The separation of three synthetic water-soluble dyes (sunset yellow FCF, carmoisine and green S) was in a gradient elution mode (0.02% ammonium acetate, pH 6.7 - water) with flow rate of 3.0mLmin -1 corresponding with sample throughput of 30h -1 . Spectrophotometric detection wavelengths were set to 480, 516 and 630nm and 10Hz data collection rate. The performance of the separation was described and discussed (peak capacities 3.48-7.67, peak symmetries 1.72-1.84 and resolutions 1.42-1.88). The method was represented by validation parameters: LODs of 0.15-0.35mgL -1 , LOQs of 0.50-1.25mgL -1 , calibration ranges 0.50-150.00mgL -1 (r>0.998) and repeatability at 10.0mgL -1 of RSD≤0.98% (n=6). The method was used for determination of the dyes in "forest berries" colored pharmaceutical cough-cold formulation. The sample matrix - pharmaceuticals and excipients were not interfering with vis determination because of no retention in the separation column and colorless nature. The results proved the concept of fast and green chromatography approach using very short medium polar monolithic column in SIC. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Determination of ambroxol hydrochloride, methylparaben and benzoic acid in pharmaceutical preparations based on sequential injection technique coupled with monolithic column.

    PubMed

    Satínský, Dalibor; Huclová, Jitka; Ferreira, Raquel L C; Montenegro, Maria Conceição B S M; Solich, Petr

    2006-02-13

    The porous monolithic columns show high performance at relatively low pressure. The coupling of short monoliths with sequential injection technique (SIA) results in a new approach to implementation of separation step to non-separation low-pressure method. In this contribution, a new separation method for simultaneous determination of ambroxol, methylparaben and benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith SpeedROD RP-18e, 50-4.6 mm column with 10 mm precolumn and a FIAlab 3000 system with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-tetrahydrofuran-0.05M acetic acid (10:10:90, v/v/v), pH 3.75 adjusted with triethylamine, flow rate 0.48 mlmin(-1), UV-detection was at 245 nm. The analysis time was <11 min. A new SIC method was validated and compared with HPLC. The method was found to be useful for the routine analysis of the active compounds ambroxol and preservatives (methylparaben or benzoic acid) in various pharmaceutical syrups and drops.

  5. Sequential Injection Chromatography with an Ultra-short Monolithic Column for the Low-Pressure Separation of α-Tocopherol and γ-Oryzanol in Vegetable Oils and Nutrition Supplements.

    PubMed

    Thaithet, Sujitra; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai

    2017-01-01

    A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R s = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R 2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.

  6. Sequential injection-bead injection-lab-on-valve coupled to high-performance liquid chromatography for online renewable micro-solid-phase extraction of carbamate residues in food and environmental samples.

    PubMed

    Vichapong, Jitlada; Burakham, Rodjana; Srijaranai, Supalax; Grudpan, Kate

    2011-07-01

    A sequential injection-bead injection-lab-on-valve system was hyphenated to HPLC for online renewable micro-solid-phase extraction of carbamate insecticides. The carbamates studied were isoprocarb, methomyl, carbaryl, carbofuran, methiocarb, promecarb, and propoxur. LiChroprep(®) RP-18 beads (25-40 μm) were employed as renewable sorbent packing in a microcolumn situated inside the LOV platform mounted above the multiposition valve of the sequential injection system. The analytes sorbed by the microcolumn were eluted using 80% acetonitrile in 0.1% acetic acid before online introduction to the HPLC system. Separation was performed on an Atlantis C-18 column (4.6 × 150 mm, 5 μm) utilizing gradient elution with a flow rate of 1.0 mL/min and a detection wavelength at 270 nm. The sequential injection system offers the means of performing automated handling of sample preconcentration and matrix removal. The enrichment factors ranged between 20 and 125, leading to limits of detection (LODs) in the range of 1-20 μg/L. Good reproducibility was obtained with relative standard deviations of <0.7 and 5.4% for retention time and peak area, respectively. The developed method has been successfully applied to the determination of carbamate residues in fruit, vegetable, and water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Two-column sequential injection chromatography--new approach for fast and effective analysis and its comparison with gradient elution chromatography.

    PubMed

    Chocholous, Petr; Satínský, Dalibor; Sklenárová, Hana; Solich, Petr

    2010-05-23

    This work presents novel approach in low-pressure chromatography flow systems--two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab, USA) with two commercially available monolithic columns the "first column" Chromolith Flash RP-18e (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith RP-18e (10 mm x 4.6 mm i.d.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 microL of filtered supernatant was injected on each column (2 x 10 microL). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 microg mL(-1) for paracetamol, at 0.5 microg mL(-1) for caffeine and at 0.7 microg mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.). Copyright 2010 Elsevier B.V. All rights reserved.

  8. Enhanced capabilities of separation in Sequential Injection Chromatography--fused-core particle column and its comparison with narrow-bore monolithic column.

    PubMed

    Chocholouš, Petr; Kosařová, Lucie; Satínský, Dalibor; Sklenářová, Hana; Solich, Petr

    2011-08-15

    In the Sequential Injection Chromatography (SIC) only monolithic columns for chromatographic separations have been used so far. This article presents the first use of fused-core particle packed column in an attempt to extend of the chromatographic capabilities of the SIC system. A new fused-core particle column (2.7 μm) Ascentis(®) Express C18 (Supelco™ Analytical) 30 mm × 4.6 mm brings high separation efficiency within flow rates and pressures comparable to monolithic column Chromolith(®) Performance RP-18e 100-3 (Merck(®)) 100 mm × 3 mm. Both columns matches the conditions of the commercially produced SIC system - SIChrom™ (8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with 4 mL reservoir - maximal work pressure 1000 PSI) (FIAlab(®), USA). The system was tested by the separation of four estrogens with similar structure and an internal standard - ethylparaben. The mobile phase composed of acetonitrile/water (40/60 (v/v)) was pumped isocratic at flow rate 0.48 mL min(-1). Spectrophotometric detection was performed at wavelength of 225 nm and injected volume of sample solutions was 10 μL. The chromatographic characteristics of both columns were compared. Obtained results and conclusions have shown that both fused-core particle column and longer narrow shaped monolithic column bring benefits into the SIC method. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Comprehensive analysis of pharmaceutical products using simultaneous mixed-mode (ion-exchange/reversed-phase) and hydrophilic interaction liquid chromatography.

    PubMed

    Kazarian, Artaches A; Nesterenko, Pavel N; Soisungnoen, Phimpha; Burakham, Rodjana; Srijaranai, Supalax; Paull, Brett

    2014-08-01

    Liquid chromatographic assays were developed using a mixed-mode column coupled in sequence with a hydrophilic interaction liquid chromatography column to allow the simultaneous comprehensive analysis of inorganic/organic anions and cations, active pharmaceutical ingredients, and excipients (carbohydrates). The approach utilized dual sample injection and valve-mediated column switching and was based upon a single high-performance liquid chromatography gradient pump. The separation consisted of three distinct sequential separation mechanisms, namely, (i) ion-exchange, (ii) mixed-mode interactions under an applied dual gradient (reversed-phase/ion-exchange), and (iii) hydrophilic interaction chromatography. Upon first injection, the Scherzo SS C18 column (Imtakt) provided resolution of inorganic anions and cations under isocratic conditions, followed by a dual organic/salt gradient to elute active pharmaceutical ingredients and their respective organic counterions and potential degradants. At the top of the mixed-mode gradient (high acetonitrile content), the mobile phase flow was switched to a preconditioned hydrophilic interaction liquid chromatography column, and the standard/sample was reinjected for the separation of hydrophilic carbohydrates, some of which are commonly known excipients in drug formulations. The approach afforded reproducible separation and resolution of up to 23 chemically diverse solutes in a single run. The method was applied to investigate the composition of commercial cough syrups (Robitussin®), allowing resolution and determination of inorganic ions, active pharmaceutical ingredients, excipients, and numerous well-resolved unknown peaks. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Ratio of sequential chromatograms for quantitative analysis and peak deconvolution: Application to standard addition method and process monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Synovec, R.E.; Johnson, E.L.; Bahowick, T.J.

    1990-08-01

    This paper describes a new technique for data analysis in chromatography, based on taking the point-by-point ratio of sequential chromatograms that have been base line corrected. This ratio chromatogram provides a robust means for the identification and the quantitation of analytes. In addition, the appearance of an interferent is made highly visible, even when it coelutes with desired analytes. For quantitative analysis, the region of the ratio chromatogram corresponding to the pure elution of an analyte is identified and is used to calculate a ratio value equal to the ratio of concentrations of the analyte in sequential injections. For themore » ratio value calculation, a variance-weighted average is used, which compensates for the varying signal-to-noise ratio. This ratio value, or equivalently the percent change in concentration, is the basis of a chromatographic standard addition method and an algorithm to monitor analyte concentration in a process stream. In the case of overlapped peaks, a spiking procedure is used to calculate both the original concentration of an analyte and its signal contribution to the original chromatogram. Thus, quantitation and curve resolution may be performed simultaneously, without peak modeling or curve fitting. These concepts are demonstrated by using data from ion chromatography, but the technique should be applicable to all chromatographic techniques.« less

  11. Therapeutic effect for liver-metastasized tumor by sequential intravenous injection of anionic polymer and cationic lipoplex of siRNA.

    PubMed

    Hattori, Yoshiyuki; Arai, Shohei; Kikuchi, Takuto; Ozaki, Kei-Ichi; Kawano, Kumi; Yonemochi, Etsuo

    2016-04-01

    Previously, we developed a novel siRNA transfer method to the liver by sequential intravenous injection of anionic polymer and cationic liposome/siRNA complex (cationic lipoplex). In this study, we investigated whether siRNA delivered by this sequential injection could significantly suppress mRNA expression of the targeted gene in liver metastasis and inhibit tumor growth. When cationic lipoplex was intravenously injected into mice bearing liver metastasis of human breast tumor MCF-7 at 1 min after intravenous injection of chondroitin sulfate C (CS) or poly-l-glutamic acid (PGA), siRNA was accumulated in tumor-metastasized liver. In terms of a gene silencing effect, sequential injections of CS or PGA plus cationic lipoplex of luciferase siRNA could reduce luciferase activity in liver MCF-7-Luc metastasis. Regarding the side effects, sequential injections of CS plus cationic lipoplex did not exhibit hepatic damage or induction of inflammatory cytokines in serum after repeated injections, but sequential injections of PGA plus cationic lipoplex did. Finally, sequential injections of CS plus cationic lipoplex of protein kinase N3 siRNA could suppress tumor growth in the mice bearing liver metastasis. From these findings, sequential injection of CS and cationic lipoplex of siRNA might be a novel systemic method of delivering siRNA to liver metastasis.

  12. Determination of yeast assimilable nitrogen content in wine fermentations by sequential injection analysis with spectrophotometric detetection.

    PubMed

    Muik, Barbara; Edelmann, Andrea; Lendl, Bernhard; Ayora-Cañada, María José

    2002-09-01

    An automated method for measuring the primary amino acid concentration in wine fermentations by sequential injection analysis with spectrophotometric detection was developed. Isoindole-derivatives from the primary amino acid were formed by reaction with o-phthaldialdehyde and N-acetyl- L-cysteine and measured at 334 nm with respect to a baseline point at 700 nm to compensate the observed Schlieren effect. As the reaction kinetic was strongly matrix dependent the analytical readout at the final reaction equilibrium has been evaluated. Therefore four parallel reaction coils were included in the flow system to be capable of processing four samples simultaneously. Using isoleucine as the representative primary amino acid in wine fermentations a linear calibration curve from 2 to 10 mM isoleucine, corresponding to 28 to 140 mg nitrogen/L (N/L) was obtained. The coefficient of variation of the method was 1.5% at a throughput of 12 samples per hour. The developed method was successfully used to monitor two wine fermentations during alcoholic fermentation. The results were in agreement with an external reference method based on high performance liquid chromatography. A mean-t-test showed no significant differences between the two methods at a confidence level of 95%.

  13. On-line hyphenation of solid-phase extraction to chromatographic separation of sulfonamides with fused-core columns in sequential injection chromatography.

    PubMed

    Batista, Alex D; Chocholouš, Petr; Satínský, Dalibor; Solich, Petr; Rocha, Fábio R P

    2015-02-01

    On-line sample pretreatment (clean-up and analyte preconcentration) is for the first time coupled to sequential injection chromatography. The approach combines anion-exchange solid-phase extraction and the highly effective pentafluorophenylpropyl (F5) fused-core particle column for separation of eight sulfonamide antibiotics with similar structures (sulfathiazole, sulfanilamide, sulfacetamide, sulfadiazine, sulfamerazine, sulfadimidine, sulfamethoxazole and sulfadimethoxine). The stationary phase was selected after a critical comparison of the performance achieved by three fused-core reversed phase columns (Ascentis(®) Express RP-Amide, Phenyl-Hexyl, and F5) and two monolithic columns (Chromolith(®) High Resolution RP-18 and CN). Acetonitrile and acetate buffer pH 5.0 at 0.60 mL min(-1) were used as mobile phase to perform the separations before spectrophotometric detection. The first mobile phase was successfully used as eluent from SPE column ensuring transfer of a narrow zone to the chromatographic column. Enrichment factors up to 39.2 were achieved with a 500 µL sample volume. The developed procedure showed analysis time <10.5 min, resolutions >1.83 with peak symmetry ≤1.52, LODs between 4.9 and 27 µg L(-1), linear response ranges from 30.0 to 1000.0 µg L(-1) (r(2)>0.996) and RSDs of peak heights <2.9% (n=6) at a 100 µg L(-1) level and enabled the screening control of freshwater samples contaminated at the 100 µg L(-1) level. The proposed approach expanded the analytical potentiality of SIC and avoided the time-consuming batch sample pretreatment step, thus minimizing risks of sample contamination and analyte losses. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. A rapid method for the simultaneous quantification of the major tocopherols, carotenoids, free and esterified sterols in canola (Brassica napus) oil using normal phase liquid chromatography.

    PubMed

    Flakelar, Clare L; Prenzler, Paul D; Luckett, David J; Howitt, Julia A; Doran, Gregory

    2017-01-01

    A normal phase high performance liquid chromatography (HPLC) method was developed to simultaneously quantify several prominent bioactive compounds in canola oil vis. α-tocopherol, γ-tocopherol, δ-tocopherol, β-carotene, lutein, β-sitosterol, campesterol and brassicasterol. The use of sequential diode array detection (DAD) and tandem mass spectrometry (MS/MS) allowed direct injection of oils, diluted in hexane without derivatisation or saponification, greatly reducing sample preparation time, and permitting the quantification of both free sterols and intact sterol esters. Further advantages over existing methods included increased analytical selectivity, and a chromatographic run time substantially less than other reported normal phase methods. The HPLC-DAD-MS/MS method was applied to freshly extracted canola oil samples as well as commercially available canola, palm fruit, sunflower and olive oils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Simultaneous determination of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wang, Yuanyuan; Li, Xiaowei; Zhang, Zhiwen; Ding, Shuangyang; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong; Xia, Xi

    2016-02-01

    A sensitive, confirmatory ultra-high performance liquid chromatography-tandem mass spectrometric method was developed and validated to detect 23 veterinary drugs and metabolites (nitroimidazoles, benzimidazoles, and chloramphenicol components) in bovine milk. Compounds of interest were sequentially extracted from milk with acetonitrile and basified acetonitrile using sodium chloride to induce liquid-liquid partition. The extract was purified on a mixed mode solid-phase extraction cartridge. Using rapid polarity switching in electrospray ionization, a single injection was capable of detecting both positively and negatively charged analytes in a 9 min chromatography run time. Recoveries based on matrix-matched calibrations and isotope labeled internal standards for milk ranged from 51.7% to 101.8%. The detection limits and quantitation limits of the analytical method were found to be within the range of 2-20 ng/kg and 5-50 ng/kg, respectively. The recommended method is simple, specific, and reliable for the routine monitoring of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Sequential intravenous injection of anionic polymer and cationic lipoplex of siRNA could effectively deliver siRNA to the liver.

    PubMed

    Hattori, Yoshiyuki; Arai, Shohei; Okamoto, Ryou; Hamada, Megumi; Kawano, Kumi; Yonemochi, Etsuo

    2014-12-10

    In this study, we developed novel siRNA transfer method to the liver by sequential intravenous injection of anionic polymer and cationic liposome/cholesterol-modified siRNA complex (cationic lipoplex). When cationic lipoplex was intravenously injected into mice, the accumulation of siRNA was mainly observed in the lungs. In contrast, when cationic lipoplex was intravenously injected at 1 min after intravenous injection of poly-L-glutamic acid (PGA) or chondroitin sulfate C (CS), siRNA was accumulated in the liver. In terms of suppression of gene expression in vivo, apolipoprotein B (ApoB) mRNA in the liver and low-density-lipoprotein (LDL) and very low-density-lipoprotein (VLDL) cholesterol level in serum were reduced at 48 h after single sequential injection of PGA or CS plus cationic lipoplex of cholesterol-modified ApoB siRNA. Furthermore, sequential injections of PGA plus cationic lipoplex of cholesterol-modified luciferase siRNA could reduce luciferase activity in tumor xenografts bearing liver metastasis of human breast tumor MCF-7-Luc. From these findings, sequential injection of anionic polymer and cationic lipoplex of siRNA might produce a systemic vector of siRNA to the liver. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. In vivo comparison of simultaneous versus sequential injection technique for thermochemical ablation in a porcine model.

    PubMed

    Cressman, Erik N K; Shenoi, Mithun M; Edelman, Theresa L; Geeslin, Matthew G; Hennings, Leah J; Zhang, Yan; Iaizzo, Paul A; Bischof, John C

    2012-01-01

    To investigate simultaneous and sequential injection thermochemical ablation in a porcine model, and compare them to sham and acid-only ablation. This IACUC-approved study involved 11 pigs in an acute setting. Ultrasound was used to guide placement of a thermocouple probe and coaxial device designed for thermochemical ablation. Solutions of 10 M acetic acid and NaOH were used in the study. Four injections per pig were performed in identical order at a total rate of 4 mL/min: saline sham, simultaneous, sequential, and acid only. Volume and sphericity of zones of coagulation were measured. Fixed specimens were examined by H&E stain. Average coagulation volumes were 11.2 mL (simultaneous), 19.0 mL (sequential) and 4.4 mL (acid). The highest temperature, 81.3°C, was obtained with simultaneous injection. Average temperatures were 61.1°C (simultaneous), 47.7°C (sequential) and 39.5°C (acid only). Sphericity coefficients (0.83-0.89) had no statistically significant difference among conditions. Thermochemical ablation produced substantial volumes of coagulated tissues relative to the amounts of reagents injected, considerably greater than acid alone in either technique employed. The largest volumes were obtained with sequential injection, yet this came at a price in one case of cardiac arrest. Simultaneous injection yielded the highest recorded temperatures and may be tolerated as well as or better than acid injection alone. Although this pilot study did not show a clear advantage for either sequential or simultaneous methods, the results indicate that thermochemical ablation is attractive for further investigation with regard to both safety and efficacy.

  18. Accelerated drug release and clearance of PEGylated epirubicin liposomes following repeated injections: a new challenge for sequential low-dose chemotherapy

    PubMed Central

    Yang, Qiang; Ma, Yanling; Zhao, Yongxue; She, Zhennan; Wang, Long; Li, Jie; Wang, Chunling; Deng, Yihui

    2013-01-01

    Background Sequential low-dose chemotherapy has received great attention for its unique advantages in attenuating multidrug resistance of tumor cells. Nevertheless, it runs the risk of producing new problems associated with the accelerated blood clearance phenomenon, especially with multiple injections of PEGylated liposomes. Methods Liposomes were labeled with fluorescent phospholipids of 1,2-dipalmitoyl-snglycero-3-phosphoethanolamine-N-(7-nitro-2-1,3-benzoxadiazol-4-yl) and epirubicin (EPI). The pharmacokinetics profile and biodistribution of the drug and liposome carrier following multiple injections were determined. Meanwhile, the antitumor effect of sequential low-dose chemotherapy was tested. To clarify this unexpected phenomenon, the production of polyethylene glycol (PEG)-specific immunoglobulin M (IgM), drug release, and residual complement activity experiments were conducted in serum. Results The first or sequential injections of PEGylated liposomes within a certain dose range induced the rapid clearance of subsequently injected PEGylated liposomal EPI. Of note, the clearance of EPI was two- to three-fold faster than the liposome itself, and a large amount of EPI was released from liposomes in the first 30 minutes in a complement-activation, direct-dependent manner. The therapeutic efficacy of liposomal EPI following 10 days of sequential injections in S180 tumor-bearing mice of 0.75 mg EPI/kg body weight was almost completely abolished between the sixth and tenth day of the sequential injections, even although the subsequently injected doses were doubled. The level of PEG-specific IgM in the blood increased rapidly, with a larger amount of complement being activated while the concentration of EPI in blood and tumor tissue was significantly reduced. Conclusion Our investigation implied that the accelerated blood clearance phenomenon and its accompanying rapid leakage and clearance of drug following sequential low-dose injections may reverse the unique pharmacokinetic–toxicity profile of liposomes which deserved our attention. Therefore, a more reasonable treatment regime should be selected to lessen or even eliminate this phenomenon. PMID:23576868

  19. Polymeric microchip for the simultaneous determination of anions and cations by hydrodynamic injection using a dual-channel sequential injection microchip electrophoresis system.

    PubMed

    Gaudry, Adam J; Nai, Yi Heng; Guijt, Rosanne M; Breadmore, Michael C

    2014-04-01

    A dual-channel sequential injection microchip capillary electrophoresis system with pressure-driven injection is demonstrated for simultaneous separations of anions and cations from a single sample. The poly(methyl methacrylate) (PMMA) microchips feature integral in-plane contactless conductivity detection electrodes. A novel, hydrodynamic "split-injection" method utilizes background electrolyte (BGE) sheathing to gate the sample flows, while control over the injection volume is achieved by balancing hydrodynamic resistances using external hydrodynamic resistors. Injection is realized by a unique flow-through interface, allowing for automated, continuous sampling for sequential injection analysis by microchip electrophoresis. The developed system was very robust, with individual microchips used for up to 2000 analyses with lifetimes limited by irreversible blockages of the microchannels. The unique dual-channel geometry was demonstrated by the simultaneous separation of three cations and three anions in individual microchannels in under 40 s with limits of detection (LODs) ranging from 1.5 to 24 μM. From a series of 100 sequential injections the %RSDs were determined for every fifth run, resulting in %RSDs for migration times that ranged from 0.3 to 0.7 (n = 20) and 2.3 to 4.5 for peak area (n = 20). This system offers low LODs and a high degree of reproducibility and robustness while the hydrodynamic injection eliminates electrokinetic bias during injection, making it attractive for a wide range of rapid, sensitive, and quantitative online analytical applications.

  20. Advantages of core-shell particle columns in Sequential Injection Chromatography for determination of phenolic acids.

    PubMed

    Chocholouš, Petr; Vacková, Jana; Srámková, Ivana; Satínský, Dalibor; Solich, Petr

    2013-01-15

    Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1) (r>0.997) and a system precision of 10 mg L(-1) with a RSD ≤ 1.65%. The high performance of the chromatography process with the RP-Amide column under optimised conditions was highlighted and well documented (HETP values ≤ 10 μm, peak symmetry ≤ 1.33, resolution ≥ 1.87 and time for one analysis <8.0 min). The results of these experiments confirmed the benefits of extending chromatographic selectivity using core-shell particle column technology in a SIC manifold. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. CLOSED-LOOP STRIPPING ANALYSIS (CLSA) OF ...

    EPA Pesticide Factsheets

    Synthetic musk compounds are used as inexpensive fragrance materials for the production of perfumes and as additives to soap, detergent, and shampoo. They have been found in surface water, fish tissues, and human breast milk. The ubiquity of this class of compounds in the environment is attributable to high use and release into the environment. Current techniques for separating these compounds from fish tissues require tedious sample clean-up procedures. To obtain fat-free extracts, gel permeation chromatography (GPC), column chromatography using alumina, and silica gel, and thin layer chromatography (TLC clean-up procedures are frequently employed. Despite the considerable effort and resources devoted to these processes, a fraction of the lipids and lipid-like compounds frequently remains in the extracts. These low-level lipids foul injection liners, contaminate columns, and yield elevated baselines during gas chromatographic analysis of synthetic musk compounds. In this study, a simple method for the determination of synthetic musk compounds in fish tissues has been developed. Closed-loop stripping of saponified fish tissues in a I -L Wheaton purge- and-trap vessel, is used to strip compounds with high vapor pressures such as synthetic musks from the matrix onto a solid sorbent (Abselut Nexus). This technique is useful for screening biological tissues that contain lipids for musk compounds. Analytes are desorbed from the sorbent trap sequentially with polar an

  2. Microfluidic Device for Sequential Injection and Flushing of Solutions and its Application to Immunosensing

    NASA Astrophysics Data System (ADS)

    Nashida, Norihiro; Suzuki, Hiroaki

    A microfluidic system with injecting and flushing functions was developed. In the system, hydrophilic flow channels have a dry-film photoresist layer which facilitates the introduction of solutions from four injection ports. The injection and flushing of solutions are controlled by valves operated by electrowetting. The valves consist of gold working electrodes in the flow channels or a through-hole in the glass substrate. Solutions can be sequentially introduced through the injection ports into a reaction chamber and flushed through a valve in the through-hole. Necessary immunoassay steps can be conducted on the chip, and a target antibody can be detected electrochemically.

  3. Sequential extractions of selenium soils from Stewart Lake: total selenium and speciation measurements with ICP-MS detection.

    PubMed

    Ponce de León, Claudia A; DeNicola, Katie; Montes Bayón, Maria; Caruso, Joseph A

    2003-06-01

    Different techniques have been employed in order to evaluate the most efficient procedure for the extraction of selenium from soil as required for speciation. Selenium contaminated sediments from Stewart Lake Wetland, California were used. A strong acid mineralization of the samples gives quantitative total selenium, which is then used to estimate recoveries for the milder extraction methods. The different extraction methodologies involve the sequential use of water, buffer (phosphate, pH 7) and either acid solution (e.g. HNO3 or HCl) or basic solutions (e.g. ammonium acetate, NaOH or TMAH). Pyrophosphate extraction was also evaluated and showed that selenium was not associated with humic acids. The extractants were subsequently analyzed by size exclusion chromatography (SEC) with UV (254 and 400 nm) and on-line ICP-MS detection; anion exchange chromatography, and ion-pair reversed phase chromatography with ICP-MS detection. For sequential extractions the extraction efficiencies showed that the basic extractions were more efficient than the acidic. The difference between the acidic and the basic extraction efficiency is carried to the sulfite extraction, suggesting that whatever is not extracted by the acid is subsequently extracted by the sulfite. The species identified with the different chromatographies were selenate, selenite, elemental selenium and some organic selenium.

  4. QUANTITATIVE ANALYSIS OF 68 POLAR COMPOUNDS FROM TEN CHEMICAL CLASSES BY DIRECT AQUEOUS INJECTION GAS CHROMATOGRAPHY

    EPA Science Inventory

    Porous polymer packings have been used successfully in many applications of direct aqueous injection gas chromatography. The authors have expanded the use of aqueous injection to the quantitative analysis of 68 alcohols, acetates, ketones, ethers, sulfides, aldehydes, diols, dion...

  5. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    ERIC Educational Resources Information Center

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  6. Sequential injection analysis with chemiluminescence detection for rapid monitoring of commercial Calendula officinalis extractions.

    PubMed

    Hughes, Rachel R; Scown, David; Lenehan, Claire E

    2015-01-01

    Plant extracts containing high levels of antioxidants are desirable due to their reported health benefits. Most techniques capable of determining the antioxidant activity of plant extracts are unsuitable for rapid at-line analysis as they require extensive sample preparation and/or long analysis times. Therefore, analytical techniques capable of real-time or pseudo real-time at-line monitoring of plant extractions, and determination of extraction endpoints, would be useful to manufacturers of antioxidant-rich plant extracts. To develop a reliable method for the rapid at-line extraction monitoring of antioxidants in plant extracts. Calendula officinalis extracts were prepared from dried flowers and analysed for antioxidant activity using sequential injection analysis (SIA) with chemiluminescence (CL) detection. The intensity of CL emission from the reaction of acidic potassium permanganate with antioxidants within the extract was used as the analytical signal. The SIA-CL method was applied to monitor the extraction of C. officinalis over the course of a batch extraction to determine the extraction endpoint. Results were compared with those from ultra high performance liquid chromatography (UHPLC). Pseudo real-time, at-line monitoring showed the level of antioxidants in a batch extract of Calendula officinalis plateaued after 100 min of extraction. These results correlated well with those of an offline UHPLC study. SIA-CL was found to be a suitable method for pseudo real-time monitoring of plant extractions and determination of extraction endpoints with respect to antioxidant concentrations. The method was applied at-line in the manufacturing industry. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Expanding Lipidome Coverage Using LC-MS/MS Data-Dependent Acquisition with Automated Exclusion List Generation

    NASA Astrophysics Data System (ADS)

    Koelmel, Jeremy P.; Kroeger, Nicholas M.; Gill, Emily L.; Ulmer, Candice Z.; Bowden, John A.; Patterson, Rainey E.; Yost, Richard A.; Garrett, Timothy J.

    2017-05-01

    Untargeted omics analyses aim to comprehensively characterize biomolecules within a biological system. Changes in the presence or quantity of these biomolecules can indicate important biological perturbations, such as those caused by disease. With current technological advancements, the entire genome can now be sequenced; however, in the burgeoning fields of lipidomics, only a subset of lipids can be identified. The recent emergence of high resolution tandem mass spectrometry (HR-MS/MS), in combination with ultra-high performance liquid chromatography, has resulted in an increased coverage of the lipidome. Nevertheless, identifications from MS/MS are generally limited by the number of precursors that can be selected for fragmentation during chromatographic elution. Therefore, we developed the software IE-Omics to automate iterative exclusion (IE), where selected precursors using data-dependent topN analyses are excluded in sequential injections. In each sequential injection, unique precursors are fragmented until HR-MS/MS spectra of all ions above a user-defined intensity threshold are acquired. IE-Omics was applied to lipidomic analyses in Red Cross plasma and substantia nigra tissue. Coverage of the lipidome was drastically improved using IE. When applying IE-Omics to Red Cross plasma and substantia nigra lipid extracts in positive ion mode, 69% and 40% more molecular identifications were obtained, respectively. In addition, applying IE-Omics to a lipidomics workflow increased the coverage of trace species, including odd-chained and short-chained diacylglycerides and oxidized lipid species. By increasing the coverage of the lipidome, applying IE to a lipidomics workflow increases the probability of finding biomarkers and provides additional information for determining etiology of disease.

  8. Development of enantioselective chemiluminescence flow- and sequential-injection immunoassays for alpha-amino acids.

    PubMed

    Silvaieh, Hossein; Schmid, Martin G; Hofstetter, Oliver; Schurig, Volker; Gübitz, Gerald

    2002-01-01

    The development of an enantioselective flow-through chemiluminescence immunosensor for amino acids is described. The approach is based on a competitive assay using enantioselective antibodies. Two different instrumental approaches, a flow-injection (FIA) and a sequential-injection system (SIA), are used. Compared to the flow-injection technique, the sequential injection-mode showed better repeatability. Both systems use an immunoreactor consisting of a flow cell packed with immobilized haptens. The haptens (4-amino-L- or D-phenylalanine) are immobilized onto a hydroxysuccinimide-activated polymer (Affi-prep 10) via a tyramine spacer. Stereoselective antibodies, raised against 4-amino-L- or D-phenylalanine, are labeled with an acridinium ester. Stereoselective inhibition of binding of the acridinum-labeled antibodies to the immobilized hapten by amino acids takes place. Chiral recognition was observed not only for the hapten molecule but also for a series of different amino acids. One assay cycle including regeneration takes 6:30 min in the FIA mode and 4:40 min in the SIA mode. Using D-phenylalanine as a sample, the detection limit was found to be 6.13 pmol/ml (1.01 ng/ml) for the flow-injection immunoassay (FIIA) and 1.76 pmol/ml (0.29 ng/ml ) for the sequential-injection immunoassay (SIIA) which can be lowered to 0.22 pmol/ml (0.036 ng/ml) or 0.064 pmol/ml (0.01 ng/ml) by using a stopped flow system. The intra-assay repeatability was found to be about 5% RSD and the inter-assay repeatability below 6% (within 3 days).

  9. Evaluation of Quantitative Performance of Sequential Immobilized Metal Affinity Chromatographic Enrichment for Phosphopeptides

    PubMed Central

    Sun, Zeyu; Hamilton, Karyn L.; Reardon, Kenneth F.

    2014-01-01

    We evaluated a sequential elution protocol from immobilized metal affinity chromatography (SIMAC) employing gallium-based immobilized metal affinity chromatography (IMAC) in conjunction with titanium-dioxide-based metal oxide affinity chromatography (MOAC). The quantitative performance of this SIMAC enrichment approach, assessed in terms of repeatability, dynamic range, and linearity, was evaluated using a mixture composed of tryptic peptides from caseins, bovine serum albumin, and phosphopeptide standards. While our data demonstrate the overall consistent performance of the SIMAC approach under various loading conditions, the results also revealed that the method had limited repeatability and linearity for most phosphopeptides tested, and different phosphopeptides were found to have different linear ranges. These data suggest that, unless additional strategies are used, SIMAC should be regarded as a semi-quantitative method when used in large-scale phosphoproteomics studies in complex backgrounds. PMID:24096195

  10. Determination of picloram in natural waters employing sequential injection square wave voltammetry using the hanging mercury drop electrode.

    PubMed

    Dos Santos, Luciana B O; Masini, Jorge C

    2007-05-15

    This paper describes the development of a sequential injection analysis method to automate the determination of picloram by square wave voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. To perform these tasks, an 800muL monosegment is formed, composed by 400muL of sample and 400muL of conditioning/standard solution, in medium of 0.10molL(-1) H(2)SO(4). Homogenization of the monosegment is achieved by three flow reversals. After homogenization the mixture zone is injected toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode, at a flow rate of 50muLs(-1). After a suitable delay time, the potential is scanned from -0.5 to -1.0V versus Ag/AgCl at frequency of 300Hz and pulse height of 25mV. The linear dynamic range is observed for picloram concentrations between 0.10 and 2.50mgL(-1) fitting to the linear equation I(p)=(-2.19+/-0.03)C(picloram)+(0.096+/-0.039), with R(2)=0.9996, for which the slope is given in muALmg(-1). The detection and quantification limits are 0.036 and 0.12mgL(-1), respectively. The sampling frequency is 37h(-1) when the standard addition protocol is followed, but can be increased to 41h(-1) if the protocol to obtain in-line external calibration curve is used for quantification. The method was applied for determination of picloram in spiked water samples and the accuracy was evaluated by comparison with high performance liquid chromatography using molecular absorption at 220nm for detection. No evidences of statistically significant differences between the two methods were observed.

  11. Solvent system selectivities in countercurrent chromatography using Salicornia gaudichaudiana metabolites as practical example with off-line electrospray mass-spectrometry injection profiling.

    PubMed

    Costa, Fernanda das Neves; Jerz, Gerold; Figueiredo, Fabiana de Souza; Winterhalter, Peter; Leitão, Gilda Guimarães

    2015-03-13

    For the development of an efficient two-stage isolation process for high-speed countercurrent chromatography (HSCCC) with focus on principal metabolites from the ethyl acetate extract of the halophyte plant Salicornia gaudichaudiana, separation selectivities of two different biphasic solvent systems with similar polarities were evaluated using the elution and extrusion approach. Efficiency in isolation of target compounds is determined by the solvent system selectivity and their chronological use in multiple separation steps. The system n-hexane-ethyl acetate-methanol-water (0.5:6:0.5:6, v/v/v/v) resulted in a comprehensive separation of polyphenolic glycosides. The system n-hexane-n-butanol-water (1:1:2, v/v/v) was less universal but was highly efficient in the fractionation of positional isomers such as di-substituted cinnamic acid quinic acid derivatives. Multiple metabolite detection performed on recovered HSCCC tube fractions was done with rapid mass-spectrometry profiling by sequential off-line injections to electrospray mass-spectrometry (ESI-MS/MS). Selective ion traces of metabolites delivered reconstituted preparative HSCCC runs. Molecular weight distribution of target compounds in single HSCCC tube fractions and MS/MS fragment data were available. Chromatographic areas with strong co-elution effects and fractions of pure recoverable compounds were visualized. In total 11 metabolites have been identified and monitored. Result of this approach was a fast isolation protocol for S. gaudichaudiana metabolites using two solvent systems in a strategic sequence. The process could easily be scaled-up to larger lab-scale or industrial recovery. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Determination of nitrite and nitrate in water samples by an automated hydrodynamic sequential injection method.

    PubMed

    Somnam, Sarawut; Jakmunee, Jaroon; Grudpan, Kate; Lenghor, Narong; Motomizu, Shoji

    2008-12-01

    An automated hydrodynamic sequential injection (HSI) system with spectrophotometric detection was developed. Thanks to the hydrodynamic injection principle, simple devices can be used for introducing reproducible microliter volumes of both sample and reagent into the flow channel to form stacked zones in a similar fashion to those in a sequential injection system. The zones were then pushed to the detector and a peak profile was recorded. The determination of nitrite and nitrate in water samples by employing the Griess reaction was chosen as a model. Calibration graphs with linearity in the range of 0.7 - 40 muM were obtained for both nitrite and nitrate. Detection limits were found to be 0.3 muM NO(2)(-) and 0.4 muM NO(3)(-), respectively, with a sample throughput of 20 h(-1) for consecutive determination of both the species. The developed system was successfully applied to the analysis of water samples, employing simple and cost-effective instrumentation and offering higher degrees of automation and low chemical consumption.

  13. Sequential capillary electrophoresis analysis using optically gated sample injection and UV/vis detection.

    PubMed

    Liu, Xiaoxia; Tian, Miaomiao; Camara, Mohamed Amara; Guo, Liping; Yang, Li

    2015-10-01

    We present sequential CE analysis of amino acids and L-asparaginase-catalyzed enzyme reaction, by combing the on-line derivatization, optically gated (OG) injection and commercial-available UV-Vis detection. Various experimental conditions for sequential OG-UV/vis CE analysis were investigated and optimized by analyzing a standard mixture of amino acids. High reproducibility of the sequential CE analysis was demonstrated with RSD values (n = 20) of 2.23, 2.57, and 0.70% for peak heights, peak areas, and migration times, respectively, and the LOD of 5.0 μM (for asparagine) and 2.0 μM (for aspartic acid) were obtained. With the application of the OG-UV/vis CE analysis, sequential online CE enzyme assay of L-asparaginase-catalyzed enzyme reaction was carried out by automatically and continuously monitoring the substrate consumption and the product formation every 12 s from the beginning to the end of the reaction. The Michaelis constants for the reaction were obtained and were found to be in good agreement with the results of traditional off-line enzyme assays. The study demonstrated the feasibility and reliability of integrating the OG injection with UV/vis detection for sequential online CE analysis, which could be of potential value for online monitoring various chemical reaction and bioprocesses. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    PubMed

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  15. Stability of tacrolimus solutions in polyolefin containers.

    PubMed

    Lee, Jun H; Goldspiel, Barry R; Ryu, Sujung; Potti, Gopal K

    2016-02-01

    Results of a study to determine the stability of tacrolimus solutions stored in polyolefin containers under various temperature conditions are reported. Triplicate solutions of tacrolimus (0.001, 0.01, and 0.1 mg/mL) in 0.9% sodium chloride injection or 5% dextrose injection were prepared in polyolefin containers. Some samples were stored at room temperature (20-25 °C); others were refrigerated (2-8 °C) for 20 hours and then stored at room temperature for up to 28 hours. The solutions were analyzed by stability-indicating high-performance liquid chromatography (HPLC) assay at specified time points over 48 hours. Solution pH was measured and containers were visually inspected at each time point. Stability was defined as retention of at least 90% of the initial tacrolimus concentration. All tested solutions retained over 90% of the initial tacrolimus concentration at all time points, with the exception of the 0.001-mg/mL solution prepared in 0.9% sodium chloride injection, which was deemed unstable beyond 24 hours. At all evaluated concentrations, mean solution pH values did not change significantly over 48 hours; no particle formation was detected. During storage in polyolefin bags at room temperature, a 0.001-mg/mL solution of tacrolimus was stable for 24 hours when prepared in 0.9% sodium chloride injection and for at least 48 hours when prepared in 5% dextrose injection. Solutions of 0.01 and 0.1 mg/mL prepared in either diluent were stable for at least 48 hours, and the 0.01-mg/mL tacrolimus solution was also found to be stable throughout a sequential temperature protocol. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  16. Microfabricated thermal modulator for comprehensive two-dimensional micro gas chromatography: design, thermal modeling, and preliminary testing.

    PubMed

    Kim, Sung-Jin; Reidy, Shaelah M; Block, Bruce P; Wise, Kensall D; Zellers, Edward T; Kurabayashi, Katsuo

    2010-07-07

    In comprehensive two-dimensional gas chromatography (GC x GC), a modulator is placed at the juncture between two separation columns to focus and re-inject eluting mixture components, thereby enhancing the resolution and the selectivity of analytes. As part of an effort to develop a microGC x microGC prototype, in this report we present the design, fabrication, thermal operation, and initial testing of a two-stage microscale thermal modulator (microTM). The microTM contains two sequential serpentine Pyrex-on-Si microchannels (stages) that cryogenically trap analytes eluting from the first-dimension column and thermally inject them into the second-dimension column in a rapid, programmable manner. For each modulation cycle (typically 5 s for cooling with refrigeration work of 200 J and 100 ms for heating at 10 W), the microTM is kept approximately at -50 degrees C by a solid-state thermoelectric cooling unit placed within a few tens of micrometres of the device, and heated to 250 degrees C at 2800 degrees C s(-1) by integrated resistive microheaters and then cooled back to -50 degrees C at 250 degrees C s(-1). Thermal crosstalk between the two stages is less than 9%. A lumped heat transfer model is used to analyze the device design with respect to the rates of heating and cooling, power dissipation, and inter-stage thermal crosstalk as a function of Pyrex-membrane thickness, air-gap depth, and stage separation distance. Experimental results are in agreement with trends predicted by the model. Preliminary tests using a conventional capillary column interfaced to the microTM demonstrate the capability for enhanced sensitivity and resolution as well as the modulation of a mixture of alkanes.

  17. Simultaneous versus Sequential Intratympanic Steroid Treatment for Severe-to-Profound Sudden Sensorineural Hearing Loss.

    PubMed

    Yoo, Myung Hoon; Lim, Won Sub; Park, Joo Hyun; Kwon, Joong Keun; Lee, Tae-Hoon; An, Yong-Hwi; Kim, Young-Jin; Kim, Jong Yang; Lim, Hyun Woo; Park, Hong Ju

    2016-01-01

    Severe-to-profound sudden sensorineural hearing loss (SSNHL) has a poor prognosis. We aimed to compare the efficacy of simultaneous and sequential oral and intratympanic steroids for this condition. Fifty patients with severe-to-profound SSNHL (>70 dB HL) were included from 7 centers. The simultaneous group (27 patients) received oral and intratympanic steroid injections for 2 weeks. The sequential group (23 patients) was treated with oral steroids for 2 weeks and intratympanic steroids for the subsequent 2 weeks. Pure-tone averages (PTA) and word discrimination scores (WDS) were compared before treatment and 2 weeks and 1 and 2 months after treatment. Treatment outcomes according to the modified American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) criteria were also analyzed. The improvement in PTA and WDS at the 2-week follow-up was 23 ± 21 dB HL and 20 ± 39% in the simultaneous group and 31 ± 29 dB HL and 37 ± 42% in the sequential group; this was not statistically significant. Complete or partial recovery at the 2-week follow-up was observed in 26% of the simultaneous group and 30% of the sequential group; this was also not significant. The improvement in PTA and WDS at the 2-month follow-up was 40 ± 20 dB HL and 37 ± 35% in the simultaneous group and 41 ± 25 dB HL and 48 ± 41% in the sequential group; this was not statistically significant. Complete or partial recovery at the 2-month follow-up was observed in 33% of the simultaneous group and 35% of the sequential group; this was also not significant. Seven patients in the sequential group did not need intratympanic steroid injections for sufficient improvement after oral steroids alone. Simultaneous oral/intratympanic steroid treatment yielded a recovery similar to that produced by sequential treatment. Because the addition of intratympanic steroids can be decided upon based on the improvement after an oral steroid, the sequential regimen can be recommended to avoid unnecessary intratympanic injections. © 2017 S. Karger AG, Basel.

  18. Fractionation of sheep cheese whey by a scalable method to sequentially isolate bioactive proteins.

    PubMed

    Pilbrow, Jodi; Bekhit, Alaa El-Din A; Carne, Alan

    2016-07-15

    This study reports a procedure for the simultaneous purification of glyco(caseino)macropeptide, immunoglobulin, lactoperoxidase, lactoferrin, α-lactalbumin and β-lactoglobulin from sheep cheese sweet whey, an under-utilized by-product of cheese manufacture generated by an emerging sheep dairy industry in New Zealand. These proteins have recognized value in the nutrition, biomedical and health-promoting supplements industries. A sequential fractionation procedure using economical anion and cation exchange chromatography on HiTrap resins was evaluated. The whey protein fractionation is performed under mild conditions, requires only the adjustment of pH between ion exchange chromatography steps, does not require buffer exchange and uses minimal amounts of chemicals. The purity of the whey protein fractions generated were analyzed by reversed phase-high performance liquid chromatography and the identity of the proteins was confirmed by mass spectrometry. This scalable procedure demonstrates that several proteins of recognized value can be fractionated in reasonable yield and purity from sheep cheese whey in one streamlined process. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. A Method To Determine the Kinetics of Solute Mixing in Liquid/Liquid Formulation Dual-Chamber Syringes.

    PubMed

    Werk, Tobias; Mahler, Hanns-Christian; Ludwig, Imke Sonja; Luemkemann, Joerg; Huwyler, Joerg; Hafner, Mathias

    Dual-chamber syringes were originally designed to separate a solid substance and its diluent. However, they can also be used to separate liquid formulations of two individual drug products, which cannot be co-formulated due to technical or regulatory issues. A liquid/liquid dual-chamber syringe can be designed to achieve homogenization and mixing of both solutions prior to administration, or it can be used to sequentially inject both solutions. While sequential injection can be easily achieved by a dual-chamber syringe with a bypass located at the needle end of the syringe barrel, mixing of the two fluids may provide more challenges. Within this study, the mixing behavior of surrogate solutions in different dual-chamber syringes is assessed. Furthermore, the influence of parameters such as injection angle, injection speed, agitation, and sample viscosity were studied. It was noted that mixing was poor for the commercial dual-chamber syringes (with a bypass designed as a longitudinal ridge) when the two liquids significantly differ in their physical properties (viscosity, density). However, an optimized dual-chamber syringe design with multiple bypass channels resulted in improved mixing of liquids. Dual-chamber syringes were originally designed to separate a solid substance and its diluent. However, they can also be used to separate liquid formulations of two individual drug products. A liquid/liquid dual-chamber syringe can be designed to achieve homogenization and mixing of both solutions prior to administration, or it can be used to sequentially inject both solutions. While sequential injection can be easily achieved by a dual-chamber syringe with a bypass located at the needle end of the syringe barrel, mixing of the two fluids may provide more challenges. Within this study, the mixing behavior of surrogate solutions in different dual-chamber syringes is assessed. Furthermore, the influence of parameters such as injection angle, injection speed, agitation, and sample viscosity were studied. It was noted that mixing was poor for the commercially available dual-chamber syringes when the two liquids significantly differ in viscosity and density. However, an optimized dual-chamber syringe design resulted in improved mixing of liquids. © PDA, Inc. 2017.

  20. Use of Activated Carbon to Control Volatilization of Organic Contaminants from the Indiana Harbor Confined Disposal Facility

    DTIC Science & Technology

    2012-09-01

    PAHs (17 priority pollutant PAHs) were extracted from sediment by USEPA SW-846 Method 3545 and analyzed by gas chromatography /mass spectrometry...slurry at concentrations of 0.025, 0.05, and 0.10 g/L. The carbon- sediment mixture was equilibrated by tumbling in zero headspace jars for 15 minutes...cooled injection gas chromatography injection system at -40 °C. Once the analytes were transferred, the injection port was heated to 240 °C and

  1. Development of a sequential injection-square wave voltammetry method for determination of paraquat in water samples employing the hanging mercury drop electrode.

    PubMed

    dos Santos, Luciana B O; Infante, Carlos M C; Masini, Jorge C

    2010-03-01

    This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 µL s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), µA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): i(p) = (-20.5 ± 0.3)C (paraquat) - (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 µg L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.

  2. Consequences of on-line dialysis on polyelectrolyte molar masses determined by size-exclusion chromatography with light scattering detection.

    PubMed

    Radke, Wolfgang

    2016-02-01

    Size-exclusion chromatography with light scattering detection experiments conducted on poly(acrylic acid) neutralized to different degrees or using hydroxides with different counterions suggest that the same counterion and degree of neutralization is observed at the detector, irrespective of salt concentration, degree of neutralization and counterion at the time of injection. This strongly supports that during the chromatographic experiment the counterions of the polyelectrolyte are exchanged with those of the eluent, resulting in an effective dialysis of the polyelectrolyte solution during the size-exclusion chromatography experiment. Consequently, the refractive index increment determined by a refractive index detector equals the refractive index increment obtained after excessive dialysis against the pure eluent. Therefore, the species detected and characterized by light scattering coupled to size-exclusion chromatography are not identical to the species injected into the chromatographic system. Despite this structural change during the chromatographic experiments, the correct molar mass for the injected species is obtained by size-exclusion chromatography with light scattering detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Efficient flow injection and sequential injection methods for spectrophotometric determination of oxybenzone in sunscreens based on reaction with Ni(II).

    PubMed

    Chisvert, A; Salvador, A; Pascual-Martí, M C; March, J G

    2001-04-01

    Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LOD are adequate to the analysis requirements. The sample frequency obtained by FI is three-fold higher than that of SI analysis. SI is less reagent-consuming than FI.

  4. [Profile-effect on quality control of Houttuynia cordata injection].

    PubMed

    Lu, Hong-mei; Liang, Yi-zeng; Qian, Pin

    2005-12-01

    To find corresponding relationship between the fingerprint of Houttuynia cordata injections from different factories and their effects. Houttuynia cordata injections from six different factories were determined by gas chromatography (GC) and gas chromatography-mass spectra (GC-MS), and GC fingerprints were classified by hierarchical clustering. The anti-inflammatory activity of Houttuynia cordata injections was characterized through the rat pleurisy model induced by carrageenin and the mice ear edema model by dimethylbenzene. The anti-inflammatory effect of the injections from the first class factories on the two model was significant, while those from the second class not. GC-MS analysis result indicated that main effect compounds in Houttuynia cordata injections are methyl n-nonyl ketone, decanoylacetaldehyde, lauryl aldehyde, capryl aldehyde, beta-pinene, beta-linalool, 1-nonanol, 4-terpineol, alpha-terpineol, bornyl acetate, n-decanoic acid and acetic acid, geraniol ester etc. There is corresponding relationship between the fingerprint of Houttuynia cordata injections and effect to a certain extent.

  5. Effect of injection matrix concentration on peak shape and separation efficiency in ion chromatography.

    PubMed

    Zhang, Ya; Lucy, Charles A

    2014-12-05

    In HPLC, injection of solvents that differ from the eluent can result in peak broadening due to solvent strength mismatch or viscous fingering. Broadened, distorted or even split analyte peaks may result. Past studies of this injection-induced peak distortion in reversed phase (RPLC) and hydrophilic interaction (HILIC) liquid chromatography have led to the conclusion that the sample should be injected in the eluent or a weaker solvent. However, there have been no studies of injection-induced peak distortion in ion chromatography (IC). To address this, injection-induced effects were studied for six inorganic anions (F-, Cl-, NO2-, Br-, NO3- and SO4(2-)) on a Dionex AS23 IC column using a HCO3-/CO3(2-) eluent. The VanMiddlesworth-Dorsey injection sensitivity parameter (s) showed that IC of anions has much greater tolerance to the injection matrix (HCO3-/CO3(2-) herein) mismatch than RPLC or HILIC. Even when the injection contained a ten-fold greater concentration of HCO3-/CO3(2-) than the eluent, the peak shapes and separation efficiencies of six analyte ions did not change significantly. At more than ten-fold greater matrix concentrations, analyte anions that elute near the system peak of the matrix were distorted, and in the extreme cases exhibited a small secondary peak on the analyte peak front. These studies better guide the degree of dilution needed prior to IC analysis of anions. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Recent Electrochemical and Optical Sensors in Flow-Based Analysis

    PubMed Central

    Chailapakul, Orawon; Ngamukot, Passapol; Yoosamran, Alongkorn; Siangproh, Weena; Wangfuengkanagul, Nattakarn

    2006-01-01

    Some recent analytical sensors based on electrochemical and optical detection coupled with different flow techniques have been chosen in this overview. A brief description of fundamental concepts and applications of each flow technique, such as flow injection analysis (FIA), sequential injection analysis (SIA), all injection analysis (AIA), batch injection analysis (BIA), multicommutated FIA (MCFIA), multisyringe FIA (MSFIA), and multipumped FIA (MPFIA) were reviewed.

  7. Integrating qualitative and quantitative characterization of traditional Chinese medicine injection by high-performance liquid chromatography with diode array detection and tandem mass spectrometry.

    PubMed

    Xie, Yuan-yuan; Xiao, Xue; Luo, Juan-min; Fu, Chan; Wang, Qiao-wei; Wang, Yi-ming; Liang, Qiong-lin; Luo, Guo-an

    2014-06-01

    The present study aims to describe and exemplify an integrated strategy of the combination of qualitative and quantitative characterization of a multicomponent mixture for the quality control of traditional Chinese medicine injections with the example of Danhong injection (DHI). The standardized chemical profile of DHI has been established based on liquid chromatography with diode array detection. High-performance liquid chromatography coupled with time-of-flight mass spectrometry and high-performance liquid chromatography with electrospray multistage tandem ion-trap mass spectrometry have been developed to identify the major constituents in DHI. The structures of 26 compounds including nucleotides, phenolic acids, and flavonoid glycosides were identified or tentatively characterized. Meanwhile, the simultaneous determination of seven marker constituents, including uridine, adenosine, danshensu, protocatechuic aldehyde, p-coumaric acid, rosmarinic acid, and salvianolic acid B, in DHI was performed by multiwavelength detection based on high-performance liquid chromatography with diode array detection. The integrated qualitative and quantitative characterization strategy provided an effective and reliable pattern for the comprehensive and systematic characterization of the complex traditional Chinese medicine system. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. High-pressure liquid chromatography with direct injection of gas sample.

    PubMed

    Astanin, Anton I; Baram, Grigory I

    2017-06-09

    The conventional method of using liquid chromatography to determine the composition of a gaseous mixture entails dissolving vapors in a suitable solvent, then obtaining a chromatograph of the resulting solution. We studied the direct introduction of a gaseous sample into a C18 reversed-phase column, followed by separation of the components by HPLC with UV detection. Since the chromatography was performed at high pressure, vapors readily dissolved in the eluent and the substances separated in the column as effectively as in liquid samples. Samples were injected into the column in two ways: a) through the valve without a flow stop; b) after stopping the flow and relieving all pressure. We showed that an injectable gas volume could reach 70% of column dead volume. When an injected gaseous sample volume was less than 10% of the column dead volume, the resulting peaks were symmetrical and the column efficiency was high. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Multidimensional gas chromatography in combination with accurate mass, tandem mass spectrometry, and element-specific detection for identification of sulfur compounds in tobacco smoke.

    PubMed

    Ochiai, Nobuo; Mitsui, Kazuhisa; Sasamoto, Kikuo; Yoshimura, Yuta; David, Frank; Sandra, Pat

    2014-09-05

    A method is developed for identification of sulfur compounds in tobacco smoke extract. The method is based on large volume injection (LVI) of 10μL of tobacco smoke extract followed by selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography (GC) coupled to a hybrid quadrupole time-of-flight mass spectrometer (Q-TOF-MS) using electron ionization (EI) and positive chemical ionization (PCI), with parallel sulfur chemiluminescence detection (SCD). In order to identify each individual sulfur compound, sequential heart-cuts of 28 sulfur fractions from (1)D GC to (2)D GC were performed with the three MS detection modes (SCD/EI-TOF-MS, SCD/PCI-TOF-MS, and SCD/PCI-Q-TOF-MS). Thirty sulfur compounds were positively identified by MS library search, linear retention indices (LRI), molecular mass determination using PCI accurate mass spectra, formula calculation using EI and PCI accurate mass spectra, and structure elucidation using collision activated dissociation (CAD) of the protonated molecule. Additionally, 11 molecular formulas were obtained for unknown sulfur compounds. The determined values of the identified and unknown sulfur compounds were in the range of 10-740ngmg total particulate matter (TPM) (RSD: 1.2-12%, n=3). Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Crystallization efficiencies of inorganic polyphosphate oligomers reacted with magnesium and calcium cations using anion-exchange chromatography with particulate formation-laser scattering detector.

    PubMed

    Ando, Masaki; Imadzu, Sakiyo; Kitagawa, Shinya; Ohtani, Hajime

    2010-08-06

    A particulate formation-laser scattering detector (PFLSD) was developed and used for evaluating the crystallization efficiency of inorganic polyphosphates (PPs) that reacted with either magnesium or calcium cations. As the solutions for reactive crystallization, 0.5 M ammonium buffer (pH 9.6) containing either 0.15 M MgCl(2) or 0.15 M CaCl(2) (MAP: magnesium ammonium phosphate and HAP: hydroxyapatite solution) were used. In the case of mono- and diphosphate (P1 and P2), the significant dependences of the particulate formation efficiency on various types of both P1/P2 and MAP/HAP reaction solutions were observed with the direct sample injection mode. The PFLSD was hyphenated with the anion-exchange chromatography and the dependence of the particulate formation efficiency on the polymerization degree (n(p)) of PP oligomers, separated chromatographically, was evaluated sequentially. The significant suppression of the particulate formation for PP oligomers was clearly confirmed, i.e., the MAP and HAP reaction solutions did not produce the particulates of the PP oligomers having an n(p) value of more than 3 and 5, respectively. As the overall tendency, the particulate formation efficiency in the case of the HAP solution was superior to that in the case of the MAP solution. Copyright 2010 Elsevier B.V. All rights reserved.

  11. Rapid quantitative detection of glucose content in glucose injection by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-10-20

    This work investigates an automated technique for rapid detecting the glucose content in glucose injection by reaction headspace gas chromatography (HS-GC). This method is based on the oxidation reaction of glucose in glucose injection with potassium dichromate. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively detected by GC. The results show that the relative standard deviation (RSD) of the present method was within 2.91%, and the measured glucose contents in glucose injection closely match those quantified by the reference method (relative differences <6.45%). The new HS-GC technique is rapid, practical and can be used to the batch detection of the glucose content in glucose injection related applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Imaging the photoinduced charge injection in CdS/TiO2 nanoparticles by the sequential fluorescence mapping method

    NASA Astrophysics Data System (ADS)

    Frederice, Rafael; Lencione, Diego; Gehlen, Marcelo H.

    2017-03-01

    The combination of a sensitizer and TiO2 nanoparticles forming a photocatalytic material is a central issue in many fields of applied photochemistry. The charge injection of emissive sensitizers into the conduction band of the semiconductor TiO2 may form a photoactive region that becomes dark, or it has a very low emission signal due to the generation of sensitizer radicals. However, by sequential coupling of a selected photoredox dye, such as resazurin, the dark region may become fluorescent at the interfaces where the charge injection has taken place due to the concomitant formation of fluorescent resorufin by cascade electron transfer. Using this strategy and a total internal reflection fluorescence microscopy (TIRFM) image, the charge injection in TiO2/CdS and SiO2/TiO2/CdS nanoparticles is investigated The method allows the charge injection efficiency of the excited CdS into TiO2 to be evaluated qualitatively, explaining the differences observed for these photocatalytic materials in H2 generation.

  13. Imaging the photoinduced charge injection in CdS/TiO2 nanoparticles by the sequential fluorescence mapping method.

    PubMed

    Frederice, Rafael; Lencione, Diego; Gehlen, Marcelo H

    2017-02-10

    The combination of a sensitizer and TiO 2 nanoparticles forming a photocatalytic material is a central issue in many fields of applied photochemistry. The charge injection of emissive sensitizers into the conduction band of the semiconductor TiO 2 may form a photoactive region that becomes dark, or it has a very low emission signal due to the generation of sensitizer radicals. However, by sequential coupling of a selected photoredox dye, such as resazurin, the dark region may become fluorescent at the interfaces where the charge injection has taken place due to the concomitant formation of fluorescent resorufin by cascade electron transfer. Using this strategy and a total internal reflection fluorescence microscopy (TIRFM) image, the charge injection in TiO 2 /CdS and SiO 2 /TiO 2 /CdS nanoparticles is investigated The method allows the charge injection efficiency of the excited CdS into TiO 2 to be evaluated qualitatively, explaining the differences observed for these photocatalytic materials in H 2 generation.

  14. Sequential Injection Analysis for Optimization of Molecular Biology Reactions

    PubMed Central

    Allen, Peter B.; Ellington, Andrew D.

    2011-01-01

    In order to automate the optimization of complex biochemical and molecular biology reactions, we developed a Sequential Injection Analysis (SIA) device and combined this with a Design of Experiment (DOE) algorithm. This combination of hardware and software automatically explores the parameter space of the reaction and provides continuous feedback for optimizing reaction conditions. As an example, we optimized the endonuclease digest of a fluorogenic substrate, and showed that the optimized reaction conditions also applied to the digest of the substrate outside of the device, and to the digest of a plasmid. The sequential technique quickly arrived at optimized reaction conditions with less reagent use than a batch process (such as a fluid handling robot exploring multiple reaction conditions in parallel) would have. The device and method should now be amenable to much more complex molecular biology reactions whose variable spaces are correspondingly larger. PMID:21338059

  15. Sequential injection spectrophotometric determination of oxybenzone in lipsticks.

    PubMed

    Salvador, A; Chisvert, A; Camarasa, A; Pascual-Martí, M C; March, J G

    2001-08-01

    A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. Ethanol was also used as carrier in the SI system. Seventy-two injections per hour can be performed, which means a sample frequency of 24 h(-1) if three replicates are measured for each sample.

  16. Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system.

    PubMed

    Stefan-van Staden, Raluca-Ioana; Bokretsion, Rahel Girmai; van Staden, Jacobus F; Aboul-Enein, Hassan Y

    2006-01-01

    Carbon paste based biosensors for the determination of creatine and creatinine have been integrated into a sequential injection system. Applying the multi-enzyme sequence of creatininase (CA), and/or creatinase (CI) and sarcosine oxidase (SO), hydrogen peroxide has been detected amperometrically. The linear concentration ranges are of pmol/L to nmol/L magnitude, with very low limits of detection. The proposed SIA system can be utilized reliably for the on-line simultaneous detection of creatine and creatinine in pharmaceutical products, as well as in serum samples, with a rate of 34 samples per hour and RSD values better than 0.16% (n=10).

  17. Preparation and Biological Study of 68Ga-DOTA-alendronate

    PubMed Central

    Fakhari, Ashraf; Jalilian, Amir R.; Johari-Daha, Fariba; Shafiee-Ardestani, Mehdi; Khalaj, Ali

    2016-01-01

    Objective(s): In line with previous research on the development of conjugated bisphosphonate ligands as new bone-avid agents, in this study, DOTA-conjugated alendronate (DOTA-ALN) was synthesized and evaluated after labeling with gallium-68 (68Ga). Methods: DOTA-ALN was synthesized and characterized, followed by 68Ga-DOTA-ALN preparation, using DOTA-ALN and 68GaCl3 (pH: 4-5) at 92-95° C for 10 min. Stability tests, hydroxyapatite assay, partition coefficient calculation, biodistribution studies, and imaging were performed on the developed agent in normal rats. Results: The complex was prepared with high radiochemical purity (>99% as depicted by radio thin-layer chromatography; specific activity: 310-320 GBq/mmol) after solid phase purification and was stabilized for up to 90 min with a log P value of -2.91. Maximum ligand binding (65%) was observed in the presence of 50 mg of hydroxyapatite; a major portion of the activity was excreted through the kidneys. With the exception of excretory organs, gastrointestinal tract organs, including the liver, intestine, and colon, showed significant uptake; however, the bone uptake was low (<1%) at 30 min after the injection. The data were also confirmed by sequential imaging at 30-90 min following the intravenous injection. Conclusion: The high solubility and anionic properties of the complex led to major renal excretion and low hydroxyapatite uptake; therefore, the complex failed to demonstrate bone imaging behaviors. PMID:27408898

  18. Preparation and Biological Study of (68)Ga-DOTA-alendronate.

    PubMed

    Fakhari, Ashraf; Jalilian, Amir R; Johari-Daha, Fariba; Shafiee-Ardestani, Mehdi; Khalaj, Ali

    2016-01-01

    In line with previous research on the development of conjugated bisphosphonate ligands as new bone-avid agents, in this study, DOTA-conjugated alendronate (DOTA-ALN) was synthesized and evaluated after labeling with gallium-68 ((68)Ga). DOTA-ALN was synthesized and characterized, followed by (68)Ga-DOTA-ALN preparation, using DOTA-ALN and (68)GaCl3 (pH: 4-5) at 92-95° C for 10 min. Stability tests, hydroxyapatite assay, partition coefficient calculation, biodistribution studies, and imaging were performed on the developed agent in normal rats. The complex was prepared with high radiochemical purity (>99% as depicted by radio thin-layer chromatography; specific activity: 310-320 GBq/mmol) after solid phase purification and was stabilized for up to 90 min with a log P value of -2.91. Maximum ligand binding (65%) was observed in the presence of 50 mg of hydroxyapatite; a major portion of the activity was excreted through the kidneys. With the exception of excretory organs, gastrointestinal tract organs, including the liver, intestine, and colon, showed significant uptake; however, the bone uptake was low (<1%) at 30 min after the injection. The data were also confirmed by sequential imaging at 30-90 min following the intravenous injection. The high solubility and anionic properties of the complex led to major renal excretion and low hydroxyapatite uptake; therefore, the complex failed to demonstrate bone imaging behaviors.

  19. Determination of technetium-99 in environmental samples: a review.

    PubMed

    Shi, Keliang; Hou, Xiaolin; Roos, Per; Wu, Wangsuo

    2012-01-04

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, (99)Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. (99)Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO(4)(-). A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of (99)Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of (99)Tc. Due to the extremely low concentration of (99)Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of (99)Tc are the most important issues governing the accurate determination of (99)Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for (99)Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of (99)Tc using solid extraction or ion exchange chromatography for separation of (99)Tc, employing flow injection or sequential injection approaches are also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Depth treatment of coal-chemical engineering wastewater by a cost-effective sequential heterogeneous Fenton and biodegradation process.

    PubMed

    Fang, Yili; Yin, Weizhao; Jiang, Yanbin; Ge, Hengjun; Li, Ping; Wu, Jinhua

    2018-05-01

    In this study, a sequential Fe 0 /H 2 O 2 reaction and biological process was employed as a low-cost depth treatment method to remove recalcitrant compounds from coal-chemical engineering wastewater after regular biological treatment. First of all, a chemical oxygen demand (COD) and color removal efficiency of 66 and 63% was achieved at initial pH of 6.8, 25 mmol L -1 of H 2 O 2 , and 2 g L -1 of Fe 0 in the Fe 0 /H 2 O 2 reaction. According to the gas chromatography-mass spectrometer (GC-MS) and gas chromatography-flame ionization detector (GC-FID) analysis, the recalcitrant compounds were effectively decomposed into short-chain organic acids such as acetic, propionic, and butyric acids. Although these acids were resistant to the Fe 0 /H 2 O 2 reaction, they were effectively eliminated in the sequential air lift reactor (ALR) at a hydraulic retention time (HRT) of 2 h, resulting in a further decrease of COD and color from 120 to 51 mg L -1 and from 70 to 38 times, respectively. A low operational cost of 0.35 $ m -3 was achieved because pH adjustment and iron-containing sludge disposal could be avoided since a total COD and color removal efficiency of 85 and 79% could be achieved at an original pH of 6.8 by the above sequential process with a ferric ion concentration below 0.8 mg L -1 after the Fe 0 /H 2 O 2 reaction. It indicated that the above sequential process is a promising and cost-effective method for the depth treatment of coal-chemical engineering wastewaters to satisfy discharge requirements.

  1. A strategy for comprehensive identification of sequential constituents using ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometer, application study on chlorogenic acids in Flos Lonicerae Japonicae.

    PubMed

    Zhang, Jia-yu; Wang, Zi-jian; Li, Yun; Liu, Ying; Cai, Wei; Li, Chen; Lu, Jian-qiu; Qiao, Yan-jiang

    2016-01-15

    The analytical methodologies for evaluation of multi-component system in traditional Chinese medicines (TCMs) have been inadequate or unacceptable. As a result, the unclarity of multi-component hinders the sufficient interpretation of their bioactivities. In this paper, an ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap (UPLC-LTQ-Orbitrap)-based strategy focused on the comprehensive identification of TCM sequential constituents was developed. The strategy was characterized by molecular design, multiple ion monitoring (MIM), targeted database hits and mass spectral trees similarity filter (MTSF), and even more isomerism discrimination. It was successfully applied in the HRMS data-acquisition and processing of chlorogenic acids (CGAs) in Flos Lonicerae Japonicae (FLJ), and a total of 115 chromatographic peaks attributed to 18 categories were characterized, allowing a comprehensive revelation of CGAs in FLJ for the first time. This demonstrated that MIM based on molecular design could improve the efficiency to trigger MS/MS fragmentation reactions. Targeted database hits and MTSF searching greatly facilitated the processing of extremely large information data. Besides, the introduction of diagnostic product ions (DPIs) discrimination, ClogP analysis, and molecular simulation, raised the efficiency and accuracy to characterize sequential constituents especially position and geometric isomers. In conclusion, the results expanded our understanding on CGAs in FLJ, and the strategy could be exemplary for future research on the comprehensive identification of sequential constituents in TCMs. Meanwhile, it may propose a novel idea for analyzing sequential constituents, and is promising for quality control and evaluation of TCMs. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Application of a novel large-volume injection method using a stomach-shaped inlet liner in capillary gas chromatographic trace analysis of dioxins in human milk and plasma.

    PubMed

    Saito, Koichi; Ohmura, Atsuko; Takekuma, Mikiko; Sasano, Ryoichi; Matsuki, Yasuhiko; Nakazawa, Hiroyuki

    2007-06-01

    A newly developed large-volume injection (LVI) technique that employs a unique stomach-shaped inlet liner (SSIL) inside of a programmable temperature vaporizer was used for the determination of trace amounts of dioxins in human milk and plasma. The initial temperature and the initial dwelling time of the inlet and the kind of solvent used were found to be critical in determining the analytical sensitivity of dioxins due to the loss of these relatively volatile compounds during solvent vaporization. Human milk and plasma were purified and fractionated by pre-packed multi-layered silica-gel chromatography and activated carbon silica-gel column chromatography. A 20-microL aliquot of the fraction collected from the chromatography with toluene was directly applied to the LVI system in high-resolution gas chromatography/high-resolution mass spectrometry. Excellent correlation (r > 0.97) between the values obtained by the LVI method using the SSIL device and those by the conventional regular-volume splitless injection method was obtained for PCDDs, PCDFs and non-ortho PCBs in human milk and plasma samples.

  3. Sequential elution process

    DOEpatents

    Kingsley, I.S.

    1987-01-06

    A process and apparatus are disclosed for the separation of complex mixtures of carbonaceous material by sequential elution with successively stronger solvents. In the process, a column containing glass beads is maintained in a fluidized state by a rapidly flowing stream of a weak solvent, and the sample is injected into this flowing stream such that a portion of the sample is dissolved therein and the remainder of the sample is precipitated therein and collected as a uniform deposit on the glass beads. Successively stronger solvents are then passed through the column to sequentially elute less soluble materials. 1 fig.

  4. Inference and analysis of xenon outflow curves under multi-pulse injection in two-dimensional chromatography.

    PubMed

    Shu-Jiang, Liu; Zhan-Ying, Chen; Yin-Zhong, Chang; Shi-Lian, Wang; Qi, Li; Yuan-Qing, Fan

    2013-10-11

    Multidimensional gas chromatography is widely applied to atmospheric xenon monitoring for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). To improve the capability for xenon sampling from the atmosphere, sampling techniques have been investigated in detail. The sampling techniques are designed by xenon outflow curves which are influenced by many factors, and the injecting condition is one of the key factors that could influence the xenon outflow curves. In this paper, the xenon outflow curves of single-pulse injection in two-dimensional gas chromatography has been tested and fitted as a function of exponential modified Gaussian distribution. An inference formula of the xenon outflow curve for six-pulse injection is derived, and the inference formula is also tested to compare with its fitting formula of the xenon outflow curve. As a result, the curves of both the one-pulse and six-pulse injections obey the exponential modified Gaussian distribution when the temperature of the activated carbon column's temperature is 26°C and the flow rate of the carrier gas is 35.6mLmin(-1). The retention time of the xenon peak for one-pulse injection is 215min, and the peak width is 138min. For the six-pulse injection, however, the retention time is delayed to 255min, and the peak width broadens to 222min. According to the inferred formula of the xenon outflow curve for the six-pulse injection, the inferred retention time is 243min, the relative deviation of the retention time is 4.7%, and the inferred peak width is 225min, with a relative deviation of 1.3%. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Díaz, Laura; Llorca-Pórcel, Julio; Valor, Ignacio

    2008-08-22

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for the detection of pesticides in tap and treated wastewater was developed and validated according to the ISO/IEC 17025:1999. Key features of this method include direct injection of 100 microL of sample, an 11 min separation by means of a rapid resolution liquid chromatography system with a 4.6 mm x 50 mm, 1.8 microm particle size reverse phase column and detection by electrospray ionization (ESI) MS-MS. The limits of detection were below 15 ng L(-1) and correlation coefficients for the calibration curves in the range of 30-2000 ng L(-1) were higher than 0.99. Precision was always below 20% and accuracy was confirmed by external evaluation. The main advantages of this method are direct injection of sample without preparative procedures and low limits of detection that fulfill the requirements established by the current European regulations governing pesticide detection.

  6. The Goldilocks Principle in Phase Labeling. Minimalist and Orthogonal Phase Tagging for Chromatography-Free Mitsunobu Reaction.

    PubMed

    Szigeti, Mariann; Dobi, Zoltán; Soós, Tibor

    2018-03-02

    An inexpensive and chromatography-free Mitsunobu methodology has been developed using low molecular weight and orthogonally phase-tagged reagents, a tert-butyl-tagged highly apolar phosphine, and a water-soluble DIAD analogue. The byproduct of the Mitsunobu reactions can be removed by sequential liquid-liquid extractions using traditional solvents such as hexanes, MeOH, water, and EtOAc. Owing to the orthogonal phase labeling, the spent reagents can be regenerated. This new variant of the Mitsunobu reaction promises to provide an alternative and complementary solution for the well-known separation problem of the Mitsunobu reaction without having to resort to expensive, large molecular weight reagents and chromatography.

  7. Pharmacokinetic-pharmacodynamic study of subcutaneous injection of depot nandrolone decanoate using dried blood spots sampling coupled with ultrapressure liquid chromatography tandem mass spectrometry assays.

    PubMed

    Singh, Gurmeet K S; Turner, Leo; Desai, Reena; Jimenez, Mark; Handelsman, David J

    2014-07-01

    Testosterone (T) and nandrolone (N) esters require deep im injections by medical personnel but these often deposit injectate into sc fat so that more convenient sc self-administration may be feasible. To investigate the feasibility and pharmacology of sc injection of N decanoate in healthy men using dried blood spot (DBS) for frequent blood sampling without clinic visits. Healthy male volunteers received 100 mg N decanoate by a single sc injection. Finger-prick capillary blood was spotted onto filter paper before injection daily at home for 21 d and stored at room temperature. Venous whole blood was also spotted onto filter paper before and weekly for 3 wk after injection. DBS were extracted for assay of N and T by liquid chromatography tandem mass spectrometry in a single batch with serum concentrations estimated with adjustment for capillary blood sample volume and hematocrit to define peak (N) or nadir (T) time and concentration from individual daily measurements. Daily serum N peaked 2.50 ± 0.25 (SEM) ng/mL at a median (range) of 6 (4-13) days causing a reduction in serum T from 3.50 ± 0.57 ng/mL at baseline to a nadir of 0.38 ± 0.13 (SEM) ng/mL (89 ± 3% suppression) at a median (range) of 8 (5-16) days. Simultaneously sampled capillary, venous whole blood, and serum gave almost identical results for serum T and N. Finger-pricks and sc injections were well tolerated. This study demonstrates that A) DBS sampling with liquid chromatography mass spectrometry steroid analysis achieves frequent time sampling in the community without requiring clinic visits, venesection, or frozen serum storage, and B) androgen esters in an oil vehicle can be delivered effectively by sc injection, thus avoiding the need for medically supervised deep-im injections.

  8. Stochastic approach for an unbiased estimation of the probability of a successful separation in conventional chromatography and sequential elution liquid chromatography.

    PubMed

    Ennis, Erin J; Foley, Joe P

    2016-07-15

    A stochastic approach was utilized to estimate the probability of a successful isocratic or gradient separation in conventional chromatography for numbers of sample components, peak capacities, and saturation factors ranging from 2 to 30, 20-300, and 0.017-1, respectively. The stochastic probabilities were obtained under conditions of (i) constant peak width ("gradient" conditions) and (ii) peak width increasing linearly with time ("isocratic/constant N" conditions). The isocratic and gradient probabilities obtained stochastically were compared with the probabilities predicted by Martin et al. [Anal. Chem., 58 (1986) 2200-2207] and Davis and Stoll [J. Chromatogr. A, (2014) 128-142]; for a given number of components and peak capacity the same trend is always observed: probability obtained with the isocratic stochastic approach

  9. Monitoring lipase/esterase activity by stopped flow in a sequential injection analysis system using p-nitrophenyl butyrate.

    PubMed

    Pliego, Jorge; Mateos, Juan Carlos; Rodriguez, Jorge; Valero, Francisco; Baeza, Mireia; Femat, Ricardo; Camacho, Rosa; Sandoval, Georgina; Herrera-López, Enrique J

    2015-01-27

    Lipases and esterases are biocatalysts used at the laboratory and industrial level. To obtain the maximum yield in a bioprocess, it is important to measure key variables, such as enzymatic activity. The conventional method for monitoring hydrolytic activity is to take out a sample from the bioreactor to be analyzed off-line at the laboratory. The disadvantage of this approach is the long time required to recover the information from the process, hindering the possibility to develop control systems. New strategies to monitor lipase/esterase activity are necessary. In this context and in the first approach, we proposed a lab-made sequential injection analysis system to analyze off-line samples from shake flasks. Lipase/esterase activity was determined using p-nitrophenyl butyrate as the substrate. The sequential injection analysis allowed us to measure the hydrolytic activity from a sample without dilution in a linear range from 0.05-1.60 U/mL, with the capability to reach sample dilutions up to 1000 times, a sampling frequency of five samples/h, with a kinetic reaction of 5 min and a relative standard deviation of 8.75%. The results are promising to monitor lipase/esterase activity in real time, in which optimization and control strategies can be designed.

  10. Monitoring Lipase/Esterase Activity by Stopped Flow in a Sequential Injection Analysis System Using p-Nitrophenyl Butyrate

    PubMed Central

    Pliego, Jorge; Mateos, Juan Carlos; Rodriguez, Jorge; Valero, Francisco; Baeza, Mireia; Femat, Ricardo; Camacho, Rosa; Sandoval, Georgina; Herrera-López, Enrique J.

    2015-01-01

    Lipases and esterases are biocatalysts used at the laboratory and industrial level. To obtain the maximum yield in a bioprocess, it is important to measure key variables, such as enzymatic activity. The conventional method for monitoring hydrolytic activity is to take out a sample from the bioreactor to be analyzed off-line at the laboratory. The disadvantage of this approach is the long time required to recover the information from the process, hindering the possibility to develop control systems. New strategies to monitor lipase/esterase activity are necessary. In this context and in the first approach, we proposed a lab-made sequential injection analysis system to analyze off-line samples from shake flasks. Lipase/esterase activity was determined using p-nitrophenyl butyrate as the substrate. The sequential injection analysis allowed us to measure the hydrolytic activity from a sample without dilution in a linear range from 0.05–1.60 U/mL, with the capability to reach sample dilutions up to 1000 times, a sampling frequency of five samples/h, with a kinetic reaction of 5 min and a relative standard deviation of 8.75%. The results are promising to monitor lipase/esterase activity in real time, in which optimization and control strategies can be designed. PMID:25633600

  11. Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry.

    PubMed

    Hasegawa, Chika; Kumazawa, Takeshi; Uchigasaki, Seisaku; Lee, Xiao-Pen; Sato, Keizo; Terada, Masaru; Kurosaki, Kunihiko

    2011-10-01

    Dextromethorphan was extracted from human plasma samples (100 μL) using MonoTip C(18) tips, which are packed with C(18)-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 μL of distilled water and 50 μL of 1 mol/L glycine-sodium hydroxide buffer (pH 10). The mixture was extracted to the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 μm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug. © Springer-Verlag 2011

  12. Comparison of simultaneous and sequential administration of fentanyl-propofol for surgical abortion: a randomized single-blinded controlled trial.

    PubMed

    Gao, Wei; Sha, Baoyong; Zhao, Yuan; Fan, Zhe; Liu, Lin; Shen, Xin

    2017-08-01

    Propofol lipid emulsion (PLE) is a nanosized sedative, and it is used with a combination of salted antalgic prodrug, fentanyl citrate (FC). To illustrate the synergistic effect of mixing, we compared the sedation/analgesia resulting from simultaneous and sequential administration in surgically induced abortion (No. ChiCTR-IPC-15006153). Simultaneous group showed lower bispectral index, blood pressure, and heart rate, when cannula was inserted into the uterus. It also showed less frequency of hypertension, sinus tachycardia, movement, pain at the injection site, and additional FC. Therefore, premixing of PLE and FC enhanced the sedation and analgesia; stabilized the hemodynamics; lessened the incidence of movement and injection pain; and reduced the requirement of drugs.

  13. Sequential Injection/Electrochemical Immunoassay for Quantifying the Pesticide Metabolite 3, 5, 6-Trichloro-2-Pyridinol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Guodong; Riechers, Shawn L.; Timchalk, Chuck

    2005-12-04

    An automated and sensitive sequential injection electrochemical immunoassay was developed to monitor a potential insecticide biomarker, 3, 5, 6-trichloro-2-pyridinol. The current method involved a sequential injection analysis (SIA) system equipped with a thin-layer electrochemical flow cell and permanent magnet, which was used to fix 3,5,6-trichloro-2-pyridinol (TCP) antibody coated magnetic beads (TCP-Ab-MBs) in the reaction zone. After competitive immunoreactions among TCP-Ab-MBs, TCP analyte, and horseradish peroxidase (HRP) labeled TCP, a 3, 3?, 5, 5?-tetramethylbenzidine dihydrochloride and hydrogen peroxide (TMB-H2O2) substrate solution was injected to produce an electroactive enzymatic product. The activity of HRP tracers was monitored by a square wave voltammetricmore » scanning electroactive enzymatic product in the thin-layer flow cell. The voltammetric characteristics of the substrate and the enzymatic product were investigated under batch conditions, and the parameters of the immunoassay were optimized in the SIA system. Under the optimal conditions, the system was used to measure as low as 6 ng L-1 (ppt) TCP, which is around 50-fold lower than the value indicated by the manufacturer of the TCP RaPID Assay? kit (0.25 ug/L, colorimetric detection). The performance of the developed immunoassay system was successfully evaluated on tap water and river water samples spiked with TCP. This technique could be readily used for detecting other environmental contaminants by developing specific antibodies against contaminants and is expected to open new opportunities for environmental and biological monitoring.« less

  14. Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

    PubMed Central

    Sadeghi, Ramezan; Kobarfard, Farzad; Yazdanpanah, Hassan; Eslamizad, Samira; Bayate, Mitra

    2016-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and water for injection. Dispersive liquid-liquid microextraction procedure combined with gas chromatography-mass spectrometry was used for the extraction and determination of PAHs in the samples. Under the optimized conditions, the range of extraction recoveries and relative standard deviations (RSDs) of PAHs in water using internal standard (anthracene-d10) were in the range of 71-90% and 4-16%, respectively. Limit of detection for different PAHs were between 0.03 and 0.1 ngmL-1. The concentration of PAHs in all tap water as well as water for injection samples were lower than the limit of quantification of PAHs. This is the first study addressing the occurrence of PAHs in water for injection samples in Iran using dispersive liquid-liquid micro extraction procedure combined with gas chromatography-mass spectrometry. PMID:27642318

  15. Simultaneous injection-effective mixing analysis of palladium.

    PubMed

    Teshima, Norio; Noguchi, Daisuke; Joichi, Yasutaka; Lenghor, Narong; Ohno, Noriko; Sakai, Tadao; Motomizu, Shoji

    2010-01-01

    A novel concept of simultaneous injection-effective mixing analysis (SIEMA) is proposed, and a SIEMA method applied to the spectrophotometric determination of palladium using a water-soluble chromogenic reagent has been demonstrated. The flow configuration of SIEMA is a hybrid format of flow injection analysis (FIA), sequential injection analysis (SIA) and multicommutation in flow-based analysis. Sample and reagent solutions are aspirated into each holding coil through each solenoid valve by a syringe pump, and then the zones are simultaneously dispensed (injected) into a mixing coil by reversed flow toward a detector through a confluence point. This results in effective mixing and rapid detection with low reagent consumption.

  16. Differential effects of progesterone and genital stimulation on sequential inhibition of estrous behavior and progesterone receptor expression in the rat brain.

    PubMed

    Gómez-Camarillo, Madaí A; Beyer, Carlos; Lucio, Rosa Angélica; García-Juárez, Marcos; González-Arenas, Aliesha; Camacho-Arroyo, Ignacio; Komisaruk, Barry R; González-Flores, Oscar

    2011-05-30

    The effect of genital stimulation, either by vaginocervical stimulation (VCS) using a calibrated vaginal probe combined with manual flank stimulation (FS), or by mounts performed by the male, on the hypothalamus and preoptic area concentration of the progesterone receptors A (PR-A) and B (PR-B) was assessed in ovariectomized (ovx) estrogen-primed rats. VCS/FS or stimulation provided by male mounts, even without intromission, significantly decreased PR-B concentration in the hypoythalamus. Down regulation of PR produced by genital stimulation was quantitatively similar to that elicited by progesterone (P) administration. Bilateral or unilateral transection of the pelvic or the pudendal nerves prevented down regulation elicited by VCS/FS. Repeated VCS/FS elicited lordosis behavior in most ovx estrogen primed rats, but the lordosis intensity was lower than that observed in response to P. P administered to ovx estrogen primed rats, induced sequential inhibition, i.e., failure to display estrous behavior in response to a second P injection (24h after the initial P injection). VCS/FS failed to elicit sequential inhibition, since rats responded with normal estrous behavior to the second injection of P. This suggests that down regulation by VCS, by contrast with P, failed to inhibit the subpopulation of PR involved in the facilitation of estrous behavior by P. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Development of Lingzhi or Reishi medicinal mushroom, Ganoderma lucidum (Higher Basidiomycetes) polysaccharides injection formulation.

    PubMed

    Jiang, Yuji; He, Anle; Liu, Yanhong; Xie, Baogui; Li, Ye; Deng, Youjin; Liu, Xinrui; Liu, Qichao

    2014-01-01

    Biochemical and pharmacological research has demonstrated that Lingzhi or Reishi medicinal mushroom Ganoderma lucidum polysaccharides (GLPS) have significant anticancer, antitumor, and antioxidant activities. To investigate the effect of injecting GLPS into hosts for clinical studies, aqueous polysaccharide extracts from G. lucidum fruit bodies were purified by deproteinization using the Sevage method, anion-exchange chromatography elution (cellulose DEAE-52 chromatography), dialysis, ethanol precipitation, and active carbon and millipore membrane filtration techniques. The purified GLPS were used for injection in mice. Polysaccharide indexes, protein, tannin, heavy metal, arsenic salt, oxalate, potassium ion, resin, pH, ignition residue measurements, evaluation criterion for allergic reactions, and total solids content of the GLPS injection were all performed using the reference methods in the Chinese Pharmacopoeia. Our results showed that polysaccharide was the key component of injection mixtures. The ignition residue and total solids content in the injection mixture were 1.4% and 2.4%, respectively. The other indices were all within the expected safety ranges. Furthermore, studies from mice functional assays showed that the injection mixture improved the antifatigue capacity of mice without any effect on weight loss/gain. In addition, the injection mixture was safe, which was confirmed by allergy testing in guinea pigs. The development of a GLPS injection offers a novel approach for future medicinal mushroom utilization and holds great commercial promise.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Derenzo, Stephen E.; Moses, William W.

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method ofmore » liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.« less

  19. The Determination of Pesticidal and Non-Pesticidal Organotin Compounds by in situ Ethylation and Capillary Gas Chromatography with Pulsed Flame Photometric Detection

    EPA Science Inventory

    The concurrent determination of pesticidal and non-pesticidal organotin compounds in several water matrices, using a simultaneous in situ ethylation and liquid-liquid extraction followed by splitless injection mode capillary gas chromatography with pulsed flame photometric detect...

  20. Characterization of phenolic amides from cortex lycii by ultra high-performance liquid chromatography coupled with LTQ-Orbitrap mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography (UPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The...

  1. Differentiating organic and conventional sage by chromatographic and mass spectrometry flow-injection fingerprints

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography (UPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The...

  2. Ultra-trace level determination of diquat and paraquat residues in surface and drinking water using ion-pair liquid chromatography with tandem mass spectrometry: a comparison of direct injection and solid-phase extraction methods.

    PubMed

    Oh, Jin-Aa; Lee, Jun-Bae; Lee, Soo-Hyung; Shin, Ho-Sang

    2014-10-01

    Direct injection and solid-phase extraction methods for the determination of diquat and paraquat in surface and drinking water were developed using liquid chromatography with tandem mass spectrometry. The signal intensities of analytes based on six ion-pairing reagents were compared with each other, and 12.5 mM nonafluoropentanoic acid was selected as the best suited amongst them. A clean-up method was developed using Oasis hydrophilic-lipophilic balance; this was compared to the direct injection method, with respect to limits of detection, interference, precision, and accuracy. Limits of quantification of diquat and paraquat were 0.03 and 0.01 μg/L using the direct injection method, and 0.002 and 0.001 μg/L using the hydrophilic-lipophilic balance method. When the hydrophilic-lipophilic balance method was used to analyze target compounds in 114 surface water and 30 drinking water samples, paraquat and diquat were detected within a concentration range of 0.001-0.12 and 0.002-0.038 μg/L in surface water, respectively. When the direct injection method was used to analyze target compounds in the same samples, the detected concentrations of paraquat and diquat were within 25% in samples being >0.015 μg/L using the hydrophilic-lipophilic balance method. The liquid chromatography with tandem mass spectrometry method using direct injection can thus be used for routine monitoring of paraquat and diquat in surface and drinking water. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Sequential injection gas guns for accelerating projectiles

    DOEpatents

    Lacy, Jeffrey M [Idaho Falls, ID; Chu, Henry S [Idaho Falls, ID; Novascone, Stephen R [Idaho Falls, ID

    2011-11-15

    Gas guns and methods for accelerating projectiles through such gas guns are described. More particularly, gas guns having a first injection port located proximate a breech end of a barrel and a second injection port located longitudinally between the first injection port and a muzzle end of the barrel are described. Additionally, modular gas guns that include a plurality of modules are described, wherein each module may include a barrel segment having one or more longitudinally spaced injection ports. Also, methods of accelerating a projectile through a gas gun, such as injecting a first pressurized gas into a barrel through a first injection port to accelerate the projectile and propel the projectile down the barrel past a second injection port and injecting a second pressurized gas into the barrel through the second injection port after passage of the projectile and to further accelerate the projectile are described.

  4. Energetic electron injections and dipolarization events in Mercury's magnetotail: Substorm dynamics

    NASA Astrophysics Data System (ADS)

    Dewey, R. M.; Slavin, J. A.; Raines, J. M.; Imber, S.; Baker, D. N.; Lawrence, D. J.

    2017-12-01

    Despite its small size, Mercury's terrestrial-like magnetosphere experiences brief, yet intense, substorm intervals characterized by features similar to at Earth: loading/unloading of the tail lobes with open magnetic flux, dipolarization of the magnetic field at the inner edge of the plasma sheet, and, the focus of this presentation, energetic electron injection. We use the Gamma-Ray Spectrometer's high-time resolution (10 ms) energetic electron measurements to determine the relationship between substorm activity and energetic electron injections coincident with dipolarization fronts in the magnetotail. These dipolarizations were detected on the basis of their rapid ( 2 s) increase in the northward component of the tail magnetic field (ΔBz 30 nT), which typically persists for 10 s. We estimate the typical flow channel to be 0.15 RM, planetary convection speed of 750 km/s, cross-tail potential drop of 7 kV, and flux transport of 0.08 MWb for each dipolarization event, suggesting multiple simultaneous and sequential dipolarizations are required to unload the >1 MWb of magnetic flux typically returned to the dayside magnetosphere during a substorm interval. Indeed, while we observe most dipolarization-injections to be isolated or in small chains of events (i.e., 1-3 events), intervals of sawtooth-like injections with >20 sequential events are also present. The typical separation between dipolarization-injection events is 10 s. Magnetotail dipolarization, in addition to being a powerful source of electron acceleration, also plays a significant role in the substorm process at Mercury.

  5. Differentiating organic from conventional peppermints using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were tested for their potential in differentiating organic and conventional peppermint samples. Ten organic and ten conventional peppermint samples were examined using HPLC-UV and FI...

  6. IDENTIFICATION OF BIS(2-CHLOROETHYL) ETHER HYDROLYSIS PRODUCTS BY DIRECT AQUEOUS INJECTION GC/FT-IR

    EPA Science Inventory

    Gas chromatography coupled to Fourier-transform infrared spectroscopy (GC/FT-IR) is rapidly becoming an accepted analytical technique complementary to GC/mass spectroscopy for identifying organic compounds in mixtures at low to moderate concentrations. irect aqueous injection (DA...

  7. Method for the quantification of vanadyl porphyrins in fractions of crude oils by High Performance Liquid Chromatography-Flow Injection-Inductively Coupled Plasma Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Wandekoken, Flávia G.; Duyck, Christiane B.; Fonseca, Teresa C. O.; Saint'Pierre, Tatiana D.

    2016-05-01

    High performance liquid chromatography hyphenated by flow injection to inductively coupled plasma mass spectrometry (HPLC-FI-ICP-MS) was used to investigate V linked to porphyrins present in fractions of crude oil. First, the crude oil sample was submitted to fractionation by preparative liquid chromatography with UV detection, at the porphyrin Soret band wavelength (400 nm). The obtained porphyrin fractions were then separated in a 250 mm single column, in the HPLC, and eluted with different mobile phases (methanol or methanol:toluene (80:20; v:v)). The quantification of V-porphyrins in the fractions eluted from HPLC was carried out by online measuring the 51V isotope in the ICP-MS, against vanadyl octaethylporphine standard solutions (VO-OEP), prepared in the same solvent as the mobile phase, and injected post-column directly into the plasma. A 20 μg L- 1 Ge in methanol was used as internal standard for minimizing non-spectral interference, such as short-term variations due to injection. The mathematical treatment of the signal based on Fast Fourier Transform smoothing algorithm was employed to improve the precision. The concentrations of V as V-porphyrins were between 2.7 and 11 mg kg- 1 in the fractions, which were close to the total concentration of V in the porphyrin fractions of the studied crude oil.

  8. The Determination of Pesticidal and Non-Pesticidal Organotin Compounds in Water Matrices by in situ Ethylation and Gas Chromatography with Pulsed Flame Photometric Detection

    EPA Science Inventory

    The concurrent determination of pesticidal and non-pesticidal organotin compounds in several water matrices, using a simultaneous in situ ethylation and liquid-liquid extraction followed by splitless injection mode capillary gas chromatography with pulsed flame photometric detect...

  9. On-line DNA analysis system with rapid thermal cycling

    DOEpatents

    Swerdlow, Harold P.; Wittwer, Carl T.

    1999-01-01

    An apparatus particularly suited for subjecting biological samples to any necessary sample preparation tasks, subjecting the sample to rapid thermal cycling, and then subjecting the sample to subsequent on-line analysis using one or more of a number of analytical techniques. The apparatus includes a chromatography device including an injection means, a chromatography pump, and a chromatography column. In addition, the apparatus also contains a capillary electrophoresis device consisting of a capillary electrophoresis column with an inlet and outlet end, a means of injection, and means of applying a high voltage to cause the differential migration of species of interest through the capillary column. Effluent from the liquid chromatography column passes over the inlet end of the capillary electrophoresis column through a tee structure and when the loading of the capillary electrophoresis column is desired, a voltage supply is activated at a precise voltage and polarity over a specific duration to cause sample species to be diverted from the flowing stream to the capillary electrophoresis column. A laser induced fluorescence detector preferably is used to analyze the products separated while in the electrophoresis column.

  10. On-line DNA analysis system with rapid thermal cycling

    DOEpatents

    Swerdlow, H.P.; Wittwer, C.T.

    1999-08-10

    This application describes an apparatus particularly suited for subjecting biological samples to any necessary sample preparation tasks, subjecting the sample to rapid thermal cycling, and then subjecting the sample to subsequent on-line analysis using one or more of a number of analytical techniques. The apparatus includes a chromatography device including an injection means, a chromatography pump, and a chromatography column. In addition, the apparatus also contains a capillary electrophoresis device consisting of a capillary electrophoresis column with an inlet and outlet end, a means of injection, and means of applying a high voltage to cause the differential migration of species of interest through the capillary column. Effluent from the liquid chromatography column passes over the inlet end of the capillary electrophoresis column through a tee structure and when the loading of the capillary electrophoresis column is desired, a voltage supply is activated at a precise voltage and polarity over a specific duration to cause sample species to be diverted from the flowing stream to the capillary electrophoresis column. A laser induced fluorescence detector preferably is used to analyze the products separated while in the electrophoresis column. 6 figs.

  11. Design of LabVIEW®-based software for the control of sequential injection analysis instrumentation for the determination of morphine

    PubMed Central

    Lenehan, Claire E.; Lewis, Simon W.

    2002-01-01

    LabVIEW®-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 × 10-10 to 5 × 10-6 M) with a line of best fit of y=1.05x+8.9164 (R2 =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 × 10-8 M). The limit of detection (3σ) was determined as 5 × 10-11 M morphine. PMID:18924729

  12. Design of LabVIEW-based software for the control of sequential injection analysis instrumentation for the determination of morphine.

    PubMed

    Lenehan, Claire E; Barnett, Neil W; Lewis, Simon W

    2002-01-01

    LabVIEW-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 x 10(-10) to 5 x 10(-6) M) with a line of best fit of y=1.05(x)+8.9164 (R(2) =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 x 10(-8) M). The limit of detection (3sigma) was determined as 5 x 10(-11) M morphine.

  13. Electrochemical oxidation coupled with liquid chromatography and mass spectrometry to study the oxidative stability of active pharmaceutical ingredients in solution: A comparison of off-line and on-line approaches.

    PubMed

    Torres, Susana; Brown, Roland; Zelesky, Todd; Scrivens, Garry; Szucs, Roman; Hawkins, Joel M; Taylor, Mark R

    2016-11-30

    Stability studies of pharmaceutical drug products and pharmaceutical active substances are important to research and development in order to fully understand and maintain product quality and safety throughout its shelf-life. Oxidative forced degradation studies are among the different types of stability studies performed by the pharmaceutical industry in order to understand the intrinsic stability of drug molecules. We have been comparing the use of electrochemistry as an alternative oxidative forced degradation method to traditional forced degradation and accelerated stability studies. Using the electrochemical degradation approach the substrate oxidation takes place in a commercially available electrochemical cell and the effluent of the cell can be either a) directly infused into the mass spectrometer or b) injected in a chromatographic column for separation of the different products formed prior to the mass spectrometry analysis. To enable the study of large numbers of different experimental conditions and molecules we developed a new dual pump automated electrochemical screening platform. This system used a HPLC pump and autosampler to load and wash the electrochemical cell and deliver the oxidized sample plug to a second injection loop. This system enabled the automatic sequential analyses of large numbers of different solutions under varied experimental conditions without need for operator intervention during the run sequence. Here we describe the system and evaluate its performance using a test molecule with well characterized stability and compare results to those obtained using an off-line electrochemistry approach. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Effects of large volume injection of aliphatic alcohols as sample diluents on the retention of low hydrophobic solutes in reversed-phase liquid chromatography.

    PubMed

    David, Victor; Galaon, Toma; Aboul-Enein, Hassan Y

    2014-01-03

    Recent studies showed that injection of large volume of hydrophobic solvents used as sample diluents could be applied in reversed-phase liquid chromatography (RP-LC). This study reports a systematic research focused on the influence of a series of aliphatic alcohols (from methanol to 1-octanol) on the retention process in RP-LC, when large volumes of sample are injected on the column. Several model analytes with low hydrophobic character were studied by RP-LC process, for mobile phases containing methanol or acetonitrile as organic modifiers in different proportions with aqueous component. It was found that starting with 1-butanol, the aliphatic alcohols can be used as sample solvents and they can be injected in high volumes, but they may influence the retention factor and peak shape of the dissolved solutes. The dependence of the retention factor of the studied analytes on the injection volume of these alcohols is linear, with a decrease of its value as the sample volume is increased. The retention process in case of injecting up to 200μL of upper alcohols is dependent also on the content of the organic modifier (methanol or acetonitrile) in mobile phase. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. The Functions of BRCA2 in Homologous Recombinational Repair

    DTIC Science & Technology

    2005-07-01

    human Rad5l, Rad51B and Rad51C proteins 5 homogeneity using spermidine precipitation and sequential column chromatography with hydroxyapatite , Q-Sepharose...G. G., Albala, J. S., Shen, Z., ovary mutants for XRCC4, Ku86, and DNA-PKcs (the XR -1 and Schild, D. (1998) Nucleic Acids Res. 26, 1179-1184 oh 11

  16. Online solid-phase extraction with high-performance liquid chromatography and mass spectrometry for the determination of five tannins in traditional Chinese medicine injections.

    PubMed

    Sun, Meng; Lin, Yuanyuan; Zhang, Jie; Zheng, Shaohua; Wang, Sicen

    2016-03-01

    A rapid analytical method based on online solid-phase extraction with high-performance liquid chromatography and mass spectrometry has been established and applied to the determination of tannin compounds that may cause adverse effects in traditional Chinese medicine injections. Different solid-phase extraction sorbents have been compared and the elution buffer was optimized. The performance of the method was verified by evaluation of recovery (≥40%), repeatability (RSD ≤ 6%), linearity (r(2) ≥ 0.993), and limit of quantification (≤0.35 μg/mL). Five tannin compounds, gallic acid, cianidanol, gallocatechin gallate, ellagic acid, and penta-O-galloylglucose, were identified with concentrations ranging from 3.1-37.4 μg/mL in the analyzed traditional Chinese medicine injections. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. High performance liquid chromatography determination of dexamethasone in plasma to evaluate its systemic absorption following intra-space pterygomandibular injection of twin-mix (mixture of 2 % lignocaine with 1:200,000 epinephrine and 4 mg dexamethasone): randomized control trial.

    PubMed

    Bhargava, Darpan; Deshpande, Ashwini; Thomas, Shaji; Sharma, Yogesh; Khare, Piush; Sahu, Sanjeev Kumar; Dubey, Suyash; Pandey, Ankit; Sreekumar, K

    2016-09-01

    To determine systemic absorption of dexamethasone by detection of plasma concentration using high performance liquid chromatography following its administration along with local anesthetic agent as a mixture via pterygomandibular space. A prospective randomized double-blind clinical study was undertaken to analyze the plasma concentration of dexamethasone after intra-space pterygomandibular injection along with local anesthesia. The study was performed as per split mouth model where the mandibular quadrant allocation was done on a random basis considering each of the 30 patients is included in the two study interventions (SS and CS). For the study site (SS) procedures, dexamethasone was administered as a mixture (2 % lignocaine with 1:200,000 epinephrine and 4 mg dexamethasone) intra-space. In the control site (CS) procedures, a regular standard inferior alveolar nerve block was administered, and dexamethasone was given as intramuscular injection. The plasma dexamethasone determination was done in venous blood 30- and 60-min post injection using high performance liquid chromatography (HPLC). The clinical parameters like pain; swelling; and mouth opening on the first, third, and seventh post-operative day were analyzed and compared. No significant difference was found in the clinical parameters assessed; comparative evaluation showed less swelling in the SS interventions. The plasma concentration of dexamethasone for the CS interventions was 226 ± 47 ng/ml at 30-min and 316 ± 81.6 ng/ml at 60-min post injection, and for SS, it was 221 ± 81.6 ng/ml at 30-min and 340 ± 105 ng/ml at 60-min post injection. On inter-site (CS and SS) comparison, no statistically significant difference was ascertained in dexamethasone plasma concentration at 30-min post injection (P = 0.77) and at 60-min post injection. (P = 0.32). Intra-space (pterygomandibular space) administration of dexamethasone can achieve statistically similar plasma concentration of the drug as when the same dose is administered intramuscularly with demonstration of similar clinical effects.

  18. Tenascin-C Prevents Articular Cartilage Degeneration in Murine Osteoarthritis Models.

    PubMed

    Matsui, Yuriyo; Hasegawa, Masahiro; Iino, Takahiro; Imanaka-Yoshida, Kyoko; Yoshida, Toshimichi; Sudo, Akihiro

    2018-01-01

    Objective The objective of this study was to determine whether intra-articular injections of tenascin-C (TNC) could prevent cartilage damage in murine models of osteoarthritis (OA). Design Fluorescently labeled TNC was injected into knee joints and its distribution was examined at 1 day, 4 days, 1 week, 2 weeks, and 4 weeks postinjection. To investigate the effects of TNC on cartilage degeneration after surgery to knee joints, articular spaces were filled with 100 μg/mL (group I), 10 μg/mL (group II) of TNC solution, or control (group III). TNC solution of 10 μg/mL was additionally injected twice after 3 weeks (group IV) or weekly after 1 week, 2 weeks, and 3 weeks (group V). Joint tissues were histologically assessed using the Mankin score and the modified Chambers system at 2 to 8 weeks after surgery. Results Exogenous TNC was maintained in the cartilage and synovium for 1 week after administration. Histological scores in groups I and II were better than scores in group III at 4 and 6 weeks, but progressive cartilage damage was seen in all groups 8 weeks postoperatively. Sequential TNC injections (groups IV and V) showed significantly better Mankin score than single injection (group II) at 8 weeks. Conclusion TNC administered exogenously remained in the cartilage of knee joints for 1 week, and could decelerate articular cartilage degeneration in murine models of OA. We also showed that sequential administration of TNC was more effective than a single injection. TNC could be an important molecule for prevention of articular cartilage damage.

  19. Dynamic fractionation of trace metals in soil and sediment samples using rotating coiled column extraction and sequential injection microcolumn extraction: a comparative study.

    PubMed

    Rosende, Maria; Savonina, Elena Yu; Fedotov, Petr S; Miró, Manuel; Cerdà, Víctor; Wennrich, Rainer

    2009-09-15

    Dynamic fractionation has been recognized as an appealing alternative to conventional equilibrium-based sequential extraction procedures (SEPs) for partitioning of trace elements (TE) in environmental solid samples. This paper reports the first attempt for harmonization of flow-through dynamic fractionation using two novel methods, the so-called sequential injection microcolumn (SIMC) extraction and rotating coiled column (RCC) extraction. In SIMC extraction, a column packed with the solid sample is clustered in a sequential injection system, while in RCC, the particulate matter is retained under the action of centrifugal forces. In both methods, the leachants are continuously pumped through the solid substrates by the use of either peristaltic or syringe pumps. A five-step SEP was selected for partitioning of Cu, Pb and Zn in water soluble/exchangeable, acid-soluble, easily reducible, easily oxidizable and moderately reducible fractions from 0.2 to 0.5 g samples at an extractant flow rate of 1.0 mL min(-1) prior to leachate analysis by inductively coupled plasma-atomic emission spectrometry. Similarities and discrepancies between both dynamic approaches were ascertained by fractionation of TE in certified reference materials, namely, SRM 2711 Montana Soil and GBW 07311 sediment, and two real soil samples as well. Notwithstanding the different extraction conditions set by both methods, similar trends of metal distribution were in generally found. The most critical parameters for reliable assessment of mobilizable pools of TE in worse-case scenarios are the size-distribution of sample particles, the density of particles, the content of organic matter and the concentration of major elements. For reference materials and a soil rich in organic matter, the extraction in RCC results in slightly higher recoveries of environmentally relevant fractions of TE, whereas SIMC leaching is more effective for calcareous soils.

  20. Achieving high peak capacity production for gas chromatography and comprehensive two-dimensional gas chromatography by minimizing off-column peak broadening.

    PubMed

    Wilson, Ryan B; Siegler, W Christopher; Hoggard, Jamin C; Fitz, Brian D; Nadeau, Jeremy S; Synovec, Robert E

    2011-05-27

    By taking into consideration band broadening theory and using those results to select experimental conditions, and also by reducing the injection pulse width, peak capacity production (i.e., peak capacity per separation time) is substantially improved for one dimensional (1D-GC) and comprehensive two dimensional (GC×GC) gas chromatography. A theoretical framework for determining the optimal linear gas velocity (the linear gas velocity producing the minimum H), from experimental parameters provides an in-depth understanding of the potential for GC separations in the absence of extra-column band broadening. The extra-column band broadening is referred to herein as off-column band broadening since it is additional band broadening not due to the on-column separation processes. The theory provides the basis to experimentally evaluate and improve temperature programmed 1D-GC separations, but in order to do so with a commercial 1D-GC instrument platform, off-column band broadening from injection and detection needed to be significantly reduced. Specifically for injection, a resistively heated transfer line is coupled to a high-speed diaphragm valve to provide a suitable injection pulse width (referred to herein as modified injection). Additionally, flame ionization detection (FID) was modified to provide a data collection rate of 5kHz. The use of long, relatively narrow open tubular capillary columns and a 40°C/min programming rate were explored for 1D-GC, specifically a 40m, 180μm i.d. capillary column operated at or above the optimal average linear gas velocity. Injection using standard auto-injection with a 1:400 split resulted in an average peak width of ∼1.5s, hence a peak capacity production of 40peaks/min. In contrast, use of modified injection produced ∼500ms peak widths for 1D-GC, i.e., a peak capacity production of 120peaks/min (a 3-fold improvement over standard auto-injection). Implementation of modified injection resulted in retention time, peak width, peak height, and peak area average RSD%'s of 0.006, 0.8, 3.4, and 4.0%, respectively. Modified injection onto the first column of a GC×GC coupled with another high-speed valve injection onto the second column produced an instrument with high peak capacity production (500-800peaks/min), ∼5-fold to 8-fold higher than typically reported for GC×GC. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. A UHPLC-MS/MS method for profiling multifunctional steroids in human hair.

    PubMed

    Dong, Zhen; Wang, Caihong; Zhang, Jinlan; Wang, Zhe

    2017-08-01

    It is important to profile steroids in many physiological and pathological processes. Recently, hair has been used for the long-term measurement of endogenous steroid hormones. Analyzing hair has advantages of being noninvasive and time sequential compared with other bio-specimens. Liquid chromatography-mass spectrometry (LC-MS) techniques have been widely used over the past decades; however, it is challenging to profile estrogens in hair by LC-MS, and more comprehensive steroid profiling is required. In this paper, an ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to simultaneously profile 28 multifunctional steroids, including corticosteroids (n = 6), estrogens (n = 13), androgens (n = 5) and progestogens (n = 4), in human scalp hair in a single run. To optimize the sample preparation procedure, we evaluated extraction time, post-incubation purification and hair fragment length; 30 mg hair samples were washed with hexane, cut into 5 mm pieces and incubated in methanol for 18 h at 25 °C. Methanol extraction derivatized using Girard P and dansyl chloride reagent was analyzed within 25 min using an automated injection program combined with a diverter valve switch and step analysis (AIDSA). The method was well validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, matrix effect and recovery, and was successfully applied to a steroid profile from male and female hairs. Significant differences were observed between genders. In addition, steroids showed a declining trend from the proximal to more distal hair segments; thus, care should be taken when obtaining hair samples for analysis to account for this difference in steroid levels along the length of hair. Graphical Abstract The workflow of the estabished UHPLC-MS/MS method.

  2. Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts from urban dust and diesel standard reference materials using a 2D-LC/2D-GC system.

    PubMed

    Ahmed, Trifa M; Lim, Hwanmi; Bergvall, Christoffer; Westerholm, Roger

    2013-10-01

    A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.

  3. Generating multiple independent retention index data in dual-secondary column comprehensive two-dimensional gas chromatography.

    PubMed

    Bieri, Stefan; Marriott, Philip J

    2006-12-01

    A method producing simultaneously three retention indexes for compounds has been developed for comprehensive two-dimensional gas chromatography by using a dual secondary column approach (GC x 2GC). For this purpose, the primary flow of the first dimension column was equally diverted into two secondary microbore columns of identical geometry by means of a three-way flow splitter positioned after the longitudinally modulated cryogenic system. This configuration produced a pair of comprehensive two-dimensional chromatograms and generated retention data on three different stationary phases in a single run. First dimension retention indexes were determined on a polar SolGel-Wax column under linear programmed-temperature conditions according to the van den Dool approach using primary alcohol homologues as the reference scale. Calculation of pseudoisothermal retention indexes in both second dimensions was performed on low-polarity 5% phenyl equivalent polysilphenylene/siloxane (BPX5) and 14% cyanopropylphenyl/86% dimethylpolysiloxane (BP10) columns. To construct a retention correlation map in the second dimension separation space upon which KovAts indexes can be derived, two methods exploiting "isovolatility" relationships of alkanes were developed. The first involved 15 sequential headspace samplings of selected n-alkanes by solid-phase microextraction (SPME), with each sampling followed by their injection into the GC at predetermined times during the chromatographic run. The second method extended the second dimension retention map and consisted of repetitive introduction of SPME-sampled alkane mixtures at various isothermal conditions incremented over the temperature program range. Calculated second dimension retention indexes were compared with experimental values obtained in conventional one-dimensional GC. A case study mixture including 24 suspected allergens (i.e., fragrance ingredients) was used to demonstrate the feasibility and potential of retention index information in comprehensive 2D-GC.

  4. Evaluation of a direct injection nebulizer interface for flow injection analysis and high performance liquid chromatography with inductively coupled plasma-atomic emission spectroscopic detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaFreniere, K.E.

    A direct injection nebulizer (DIN) was designed, developed, and evaluated to determine its potential utilization as an effective interface for flow injection analysis (FIA) and high performance liquid chromatography (HPLC) coupled with inductively coupled plasma-atomic emission spectroscopic detection. The analytical figures of merit for the DIN when used as an interface for FIA-ICP-AES were found to be comparable to or better than those obtained with conventional pneumatic nebulization in terms of limits of detection (LODs), reproducibility, linearity, and interelement effects. Stable plasma operation was maintained for the DIN sample introduction of a variety of pure organic solvents, including acetonitrile, methanol,more » methylisobutylketone, and pyridine. The HPLC-DIN-ICP-AES facility was specifically applied for the speciation of inorganic and organometallic species contained in synthetic mixtures, vanilla extracts, and a variety of energy-related materials, such as shale oil process water, coal extracts, shale oil, crude oil, and an SRC II. Suggestions for future research are also considered. 227 refs., 44 figs., 15 tabs.« less

  5. Analysis of Anthrax Immune Globulin Intravenous with Antimicrobial Treatment in Injection Drug Users, Scotland, 2009-2010.

    PubMed

    Cui, Xizhong; Nolen, Leisha D; Sun, Junfeng; Booth, Malcolm; Donaldson, Lindsay; Quinn, Conrad P; Boyer, Anne E; Hendricks, Katherine; Shadomy, Sean; Bothma, Pieter; Judd, Owen; McConnell, Paul; Bower, William A; Eichacker, Peter Q

    2017-01-01

    We studied anthrax immune globulin intravenous (AIG-IV) use from a 2009-2010 outbreak of Bacillus anthracis soft tissue infection in injection drug users in Scotland, UK, and we compared findings from 15 AIG-IV recipients with findings from 28 nonrecipients. Death rates did not differ significantly between recipients and nonrecipients (33% vs. 21%). However, whereas only 8 (27%) of 30 patients at low risk for death (admission sequential organ failure assessment score of 0-5) received AIG-IV, 7 (54%) of the 13 patients at high risk for death (sequential organ failure assessment score of 6-11) received treatment. AIG-IV recipients had surgery more often and, among survivors, had longer hospital stays than did nonrecipients. AIG-IV recipients were sicker than nonrecipients. This difference and the small number of higher risk patients confound assessment of AIG-IV effectiveness in this outbreak.

  6. Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification

    PubMed Central

    Murphy, Patrick J. M.; Stone, Orrin J.; Anderson, Michelle E.

    2011-01-01

    In contrast to other chromatographic methods for purifying proteins (e.g. gel filtration, affinity, and ion exchange), hydrophobic interaction chromatography (HIC) commonly requires experimental determination (referred to as screening or "scouting") in order to select the most suitable chromatographic medium for purifying a given protein 1. The method presented here describes an automated approach to scouting for an optimal HIC media to be used in protein purification. HIC separates proteins and other biomolecules from a crude lysate based on differences in hydrophobicity. Similar to affinity chromatography (AC) and ion exchange chromatography (IEX), HIC is capable of concentrating the protein of interest as it progresses through the chromatographic process. Proteins best suited for purification by HIC include those with hydrophobic surface regions and able to withstand exposure to salt concentrations in excess of 2 M ammonium sulfate ((NH4)2SO4). HIC is often chosen as a purification method for proteins lacking an affinity tag, and thus unsuitable for AC, and when IEX fails to provide adequate purification. Hydrophobic moieties on the protein surface temporarily bind to a nonpolar ligand coupled to an inert, immobile matrix. The interaction between protein and ligand are highly dependent on the salt concentration of the buffer flowing through the chromatography column, with high ionic concentrations strengthening the protein-ligand interaction and making the protein immobile (i.e. bound inside the column) 2. As salt concentrations decrease, the protein-ligand interaction dissipates, the protein again becomes mobile and elutes from the column. Several HIC media are commercially available in pre-packed columns, each containing one of several hydrophobic ligands (e.g. S-butyl, butyl, octyl, and phenyl) cross-linked at varying densities to agarose beads of a specific diameter 3. Automated column scouting allows for an efficient approach for determining which HIC media should be employed for future, more exhaustive optimization experiments and protein purification runs 4. The specific protein being purified here is recombinant green fluorescent protein (GFP); however, the approach may be adapted for purifying other proteins with one or more hydrophobic surface regions. GFP serves as a useful model protein, due to its stability, unique light absorbance peak at 397 nm, and fluorescence when exposed to UV light 5. Bacterial lysate containing wild type GFP was prepared in a high-salt buffer, loaded into a Bio-Rad DuoFlow medium pressure liquid chromatography system, and adsorbed to HiTrap HIC columns containing different HIC media. The protein was eluted from the columns and analyzed by in-line and post-run detection methods. Buffer blending, dynamic sample loop injection, sequential column selection, multi-wavelength analysis, and split fraction eluate collection increased the functionality of the system and reproducibility of the experimental approach. PMID:21968976

  7. Differentiating organically and conventionally grown oregano using ultraperformance liquid chromatography mass spectrometry (UPLC-MS), headspace gas chromatography with flame ionization detection (headspace-GC-FID), and flow injection mass spectrum (FIMS) fingerprints combined with multivariate data analysis.

    PubMed

    Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy

    2014-08-13

    Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.

  8. Use of nitrogen to remove solvent from through oven transfer adsorption desorption interface during analysis of polycyclic aromatic hydrocarbons by large volume injection in gas chromatography.

    PubMed

    Áragón, Alvaro; Toledano, Rosa M; Cortés, José M; Vázquez, Ana M; Villén, Jesús

    2014-04-25

    The through oven transfer adsorption desorption (TOTAD) interface allows large volume injection (LVI) in gas chromatography and the on-line coupling of liquid chromatography and gas chromatography (LC-GC), enabling the LC step to be carried out in normal as well as in reversed phase. However, large amounts of helium, which is both expensive and scarce, are necessary for solvent elimination. We describe how slight modification of the interface and the operating mode allows nitrogen to be used during the solvent elimination steps. In order to evaluate the performance of the new system, volumes ranging from 20 to 100μL of methanolic solutions of four polycyclic aromatic hydrocarbons (PAHs) were sampled. No significant differences were found in the repeatability and sensitivity of the analyses of standard PAH solutions when using nitrogen or helium. The performance using the proposed modification was similar and equally satisfactory when using nitrogen or helium for solvent elimination in the TOTAD interface. In conclusion, the use of nitrogen will make analyses less expensive. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. The CE-Way of Thinking: "All Is Relative!".

    PubMed

    Schmitt-Kopplin, Philippe; Fekete, Agnes

    2016-01-01

    Over the last two decades the development of capillary electrophoresis instruments lead to systems with programmable sampler, separation column, separation buffer, and detection devices comparable visually in many aspects to the setup of classical chromatography.Two processes make capillary electrophoresis essentially different from chromatography and are the basis of the CE-way of thinking, namely, the injection type and the liquid flow within the capillary. (1) When the injection is made hydrodynamically (such as in most of the found applications in the literature), the injected volumes are directly dependent on the type and size of the separation capillary. (2) The buffer velocity is not pressure driven as in liquid chromatography but electrokinetically governed by the quality of the capillary surface (separation buffer dependant surface charge) inducing an electroosmotic flow (EOF). The EOF undergoes small variations and is not necessarily identical from one separation or day to the other. The direct consequence is an apparent nonreproducible migration time of the analytes, even though the own velocity of the ions is the same.The effective mobility (field strength normalized velocity) of the ions is a possible parameterization from acquired timescale to effective mobility-scale electropherograms leading to a reproducible visualization and better quantification with a direct relation to structural characters of the analytes (i.e., charge and size-see chapter on semiempirical modelization).

  10. Drug delivery into the cochlear apex: Improved control to sequentially affect finely spaced regions along the entire length of the cochlear spiral.

    PubMed

    Lichtenhan, J T; Hartsock, J; Dornhoffer, J R; Donovan, K M; Salt, A N

    2016-11-01

    Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Drug delivery into the cochlear apex: Improved control to sequentially affect finely spaced regions along the entire length of the cochlear spiral

    PubMed Central

    Lichtenhan, JT; Hartsock, J; Dornhoffer, JR; Donovan, KM; Salt, AN

    2016-01-01

    Background Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. New method Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Results Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Conclusions Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. PMID:27506463

  12. Clean-up of a pesticide-lanolin mixture by gel permeation chromatography.

    PubMed

    López-Mesas, M; Crespi, M; Brach, J; Mullender, J P

    2000-12-01

    In this study, the efficiency of a clean-up method by gel permeation chromatography (GPC) for the separation of pesticides from lanolin is analyzed. The pesticides analyzed belong to two different families, organophosphorous and synthetic pyrethroids. Lanolin, a standard mixture of the pesticides, and a lanolin-pesticides mixture are injected in a GPC column. The recoveries and elution times from the GPC column of lanolin (by a gravimetric method) and pesticides (by gas chromatography-electron capture detector) are determined. From this column, a good separation of the lanolin-pesticides mixture is observed.

  13. A novel high-throughput method for supported liquid extraction of retinol and alpha-tocopherol from human serum and simultaneous quantitation by liquid chromatography tandem mass spectrometry.

    PubMed

    Hinchliffe, Edward; Rudge, James; Reed, Paul

    2016-07-01

    Measurement of vitamin A (retinol) and E (alpha-tocopherol) in UK clinical laboratories is currently performed exclusively by high-performance liquid chromatography with ultraviolet detection. We investigated whether retinol and alpha-tocopherol could be measured simultaneously by liquid chromatography tandem mass spectrometry. Serum samples (100 μL) were extracted using Isolute + Supported Liquid Extraction plates. Chromatography was performed on a Phenomenex Kinetex Biphenyl 2.6 μm, 50 × 2.1 mm column, and liquid chromatography tandem mass spectrometry on a Waters Acquity TQD. Injection-to-injection time was 4.3 min. The assay was validated according to published guidelines. Patient samples were used to compare liquid chromatography tandem mass spectrometry and high-performance liquid chromatography with ultraviolet detection methods. For retinol and alpha-tocopherol, respectively, the assay was linear up to 6.0 and 80.0 μmol/L, and lower limit of quantification was 0.07 and 0.26 μmol/L. Intra and interassay imprecision were within desirable analytical specifications. Analysis of quality control material aligned to NIST SRM 968e, and relative spiked recovery from human serum, both yielded results within 15% of target values. Method comparison with high-performance liquid chromatography with ultraviolet detection methodology demonstrated a negative bias for retinol and alpha-tocopherol by the liquid chromatography tandem mass spectrometry method. Analysis of United Kingdom National External Quality Assurance Scheme samples yielded mean bias from the target value of +3.0% for retinol and -11.2% for alpha-tocopherol. We have developed a novel, high-throughput method for extraction of retinol and alpha-tocopherol from human serum followed by simultaneous quantitation by liquid chromatography tandem mass spectrometry. The method offers a rapid, sensitive, specific and cost-effective alternative to high-performance liquid chromatography with ultraviolet detection methodology, and is suitable for routine clinical monitoring of patients predisposed to fat-soluble vitamin malabsorption. © The Author(s) 2015.

  14. Purification of α-glucosidase from mouse intestine by countercurrent chromatography coupled with a reverse micelle solvent system.

    PubMed

    He, Kai; Zou, Zongyao; Hu, Yinran; Yang, Yong; Xiao, Yubo; Gao, Pincao; Li, Xuegang; Ye, Xiaoli

    2016-02-01

    Countercurrent chromatography coupled with a reverse micelle solvent was applied to separate α-glucosidase, which is stable at pH 6.0-8.8, 15-50°C. The separation conditions are as follows: stationary phase: pH 4.0 Tris-HCl buffer phase containing 50 mM Tris-HCl and 50 mM KCl; mobile phase A: isooctane containing 50 mM anionic surfactant sodium di(2-ethylhexyl)sulfosuccinate; mobile phase B: 50 mM Tris-HCl buffer containing 500 mM KCl (pH 8.0); In total, 25 mL (23.9 mg) crude enzyme was injected through the injection valve, the enzymatic reaction and sodium dodecylsulfate polyacrylamide gel electrophoresis results imply that the activity of purified α-glucosidase is 6.63-fold higher than that of the crude enzyme. Therefore, countercurrent chromatography coupled with a reverse micelle solvent is capable for protein separation and enrichment. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Pseudolinear gradient ultrahigh-pressure liquid chromatography using an injection valve assembly.

    PubMed

    Xiang, Yanqiao; Liu, Yansheng; Stearns, Stanley D; Plistil, Alex; Brisbin, Martin P; Lee, Milton L

    2006-02-01

    The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).

  16. Determination of Parabens by Injection-Port Derivatization Coupled With Gas-Chromatography-Mass Spectrometry and Matrix Solid Phase Dispersion

    NASA Astrophysics Data System (ADS)

    Djatmika, Rosalina; Ding, Wang-Hsien; Sulistyarti, Hermin

    2018-01-01

    A rapid determination of four parabens preservatives (methyl paraben, ethyl paraben, propyl paraben, and butyl paraben) in marketed seafood is presented. Analytes were extracted and purified using matrix solid-phase dispersion (MSPD) method, followed by Injection port acylation gas chromatography-mass spectrometry (GC-MS) with acetic anhydride reagent. In this method, acylation of parabens was performed by acetic anhydride at GC injection-port generating reduction of the time-consuming sample-processing steps, and the amount of toxic reagents and solvents. The parameters affecting this method such as injection port temperature, purge-off time and acylation (acetic anhydride) volume were studied. In addition, the MSPD influence factors (including the amount of dispersant and clean-up co-sorbent, as well as the volume of elution solvent) were also investigated. After MSPD method and Injection port acylation applied, good linearity of analytes was achieved. The limits of quantitation (LOQs) were 0.2 to 1.0 ng/g (dry weight). Compared with offline derivatization commonly performed, injection port acylation employs a rapid, simple, low-cost and environmental-friendly derivatization process. The optimized method has been successfully applied for the analysis of parabens in four kind of marketed seafood. Preliminary results showed that the total concentrations of four selected parabens ranged from 16.7 to 44.7 ng/g (dry weight).

  17. Sequential extraction procedure for determination of uranium, thorium, radium, lead and polonium radionuclides by alpha spectrometry in environmental samples

    NASA Astrophysics Data System (ADS)

    Oliveira, J. M.; Carvalho, F. P.

    2006-01-01

    A sequential extraction technique was developed and tested for common naturally-occurring radionuclides. This technique allows the extraction and purification of uranium, thorium, radium, lead, and polonium radionuclides from the same sample. Environmental materials such as water, soil, and biological samples can be analyzed for those radionuclides without matrix interferences in the quality of radioelement purification and in the radiochemical yield. The use of isotopic tracers (232U, 229Th, 224Ra, 209Po, and stable lead carrier) added to the sample in the beginning of the chemical procedure, enables an accurate control of the radiochemical yield for each radioelement. The ion extraction procedure, applied after either complete dissolution of the solid sample with mineral acids or co-precipitation of dissolved radionuclide with MnO2 for aqueous samples, includes the use of commercially available pre-packed columns from Eichrom® and ion exchange columns packed with Bio-Rad resins, in altogether three chromatography columns. All radioactive elements but one are purified and electroplated on stainless steel discs. Polonium is spontaneously plated on a silver disc. The discs are measured using high resolution silicon surface barrier detectors. 210Pb, a beta emitter, can be measured either through the beta emission of 210Bi, or stored for a few months and determined by alpha spectrometry through the in-growth of 210Po. This sequential extraction chromatography technique was tested and validated with the analysis of certified reference materials from the IAEA. Reproducibility was tested through repeated analysis of the same homogeneous material (water sample).

  18. Evaluation of injection methods for fast, high peak capacity separations with low thermal mass gas chromatography.

    PubMed

    Fitz, Brian D; Mannion, Brandyn C; To, Khang; Hoac, Trinh; Synovec, Robert E

    2015-05-01

    Low thermal mass gas chromatography (LTM-GC) was evaluated for rapid, high peak capacity separations with three injection methods: liquid, headspace solid phase micro-extraction (HS-SPME), and direct vapor. An Agilent LTM equipped with a short microbore capillary column was operated at a column heating rate of 250 °C/min to produce a 60s separation. Two sets of experiments were conducted in parallel to characterize the instrumental platform. First, the three injection methods were performed in conjunction with in-house built high-speed cryo-focusing injection (HSCFI) to cryogenically trap and re-inject the analytes onto the LTM-GC column in a narrower band. Next, the three injection methods were performed natively with LTM-GC. Using HSCFI, the peak capacity of a separation of 50 nl of a 73 component liquid test mixture was 270, which was 23% higher than without HSCFI. Similar peak capacity gains were obtained when using the HSCFI with HS-SPME (25%), and even greater with vapor injection (56%). For the 100 μl vapor sample injected without HSCFI, the preconcentration factor, defined as the ratio of the maximum concentration of the detected analyte peak relative to the analyte concentration injected with the syringe, was determined to be 11 for the earliest eluting peak (most volatile analyte). In contrast, the preconcentration factor for the earliest eluting peak using HSCFI was 103. Therefore, LTM-GC is demonstrated to natively provide in situ analyte trapping, although not to as great an extent as with HSCFI. We also report the use of LTM-GC applied with time-of-flight mass spectrometry (TOFMS) detection for rapid, high peak capacity separations from SPME sampled banana peel headspace. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. [Determination of aspirin and free salicylic acid in lysinipirine injection by high performance liquid chromatography].

    PubMed

    Dong, Yu; Zhao, Yuan-zheng; Zhang, Yi-na

    2002-05-01

    The contents of aspirin and free salicylic acid in lysinipirine injection were determined by high performance liquid chromatography (HPLC). A Hypersil BDS C18 column was used with the mobile phase of methanol-water-acetic acid (35:65:3, volume ratio) and the detection wavelength of 280 nm. The average recoveries of aspirin and salicylic acid added were 99.27% (RSD = 0.8%) and 99.61%(RSD = 1.3%), respectively. The calibration curves had good linearity in the range of 0.028 g/L -0.141 mg/L and 0.77 mg/L -3.85 mg/L, and the correlation coefficients were 0.9999 and 0.9998 for aspirin and salicylic acid respectively.

  20. Optimization of throughput in semipreparative chiral liquid chromatography using stacked injection.

    PubMed

    Taheri, Mohammadreza; Fotovati, Mohsen; Hosseini, Seyed-Kiumars; Ghassempour, Alireza

    2017-10-01

    An interesting mode of chromatography for preparation of pure enantiomers from pure samples is the method of stacked injection as a pseudocontinuous procedure. Maximum throughput and minimal production costs can be achieved by the use of total chiral column length in this mode of chromatography. To maximize sample loading, often touching bands of the two enantiomers is automatically achieved. Conventional equations show direct correlation between touching-band loadability and the selectivity factor of two enantiomers. The important question for one who wants to obtain the highest throughput is "How to optimize different factors including selectivity, resolution, run time, and loading of the sample in order to save time without missing the touching-band resolution?" To answer this question, tramadol and propranolol were separated on cellulose 3,5-dimethyl phenyl carbamate, as two pure racemic mixtures with low and high solubilities in mobile phase, respectively. The mobile phase composition consisted of n-hexane solvent with alcohol modifier and diethylamine as the additive. A response surface methodology based on central composite design was used to optimize separation factors against the main responses. According to the stacked injection properties, two processes were investigated for maximizing throughput: one with a poorly soluble and another with a highly soluble racemic mixture. For each case, different optimization possibilities were inspected. It was revealed that resolution is a crucial response for separations of this kind. Peak area and run time are two critical parameters in optimization of stacked injection for binary mixtures which have low solubility in the mobile phase. © 2017 Wiley Periodicals, Inc.

  1. An integrated process for the recovery of high added-value compounds from olive oil using solid support free liquid-liquid extraction and chromatography techniques.

    PubMed

    Angelis, Apostolis; Hamzaoui, Mahmoud; Aligiannis, Nektarios; Nikou, Theodora; Michailidis, Dimitris; Gerolimatos, Panagiotis; Termentzi, Aikaterini; Hubert, Jane; Halabalaki, Maria; Renault, Jean-Hugues; Skaltsounis, Alexios-Léandros

    2017-03-31

    An integrated extraction and purification process for the direct recovery of high added value compounds from extra virgin olive oil (EVOO) is proposed by using solid support free liquid-liquid extraction and chromatography techniques. Two different extraction methods were developed on a laboratory-scale Centrifugal Partition Extractor (CPE): a sequential strategy consisting of several "extraction-recovery" cycles and a continuous strategy based on stationary phase co-current elution. In both cases, EVOO was used as mobile phase diluted in food grade n-hexane (feed mobile phase) and the required biphasic system was obtained by adding ethanol and water as polar solvents. For the sequential process, 17.5L of feed EVOO containing organic phase (i.e. 7L of EVOO treated) were extracted yielding 9.5g of total phenolic fraction corresponding to a productivity of 5.8g/h/L of CPE column. Regarding the second approach, the co-current process, 2L of the feed oil phase (containing to 0.8L of EVOO) were treated at 100mL/min yielding 1.03g of total phenolic fraction corresponding to a productivity of 8.9g/h/L of CPE column. The total phenolic fraction was then fractionated by using stepwise gradient elution Centrifugal Partition Chromatography (CPC). The biphasic solvent systems were composed of n-hexane, ethyl acetate, ethanol and water in different proportions (X/Y/2/3, v/v). In a single run of 4h on a column with a capacity of 1L, 910mg of oleocanthal, 882mg of oleacein, 104mg of hydroxytyrosol were successfully recovered from 5g of phenolic extract with purities of 85%, 92% and 90%, respectively. CPC fractions were then submitted to orthogonal chromatographic steps (adsorption on silica gel or size exclusion chromatography) leading to the isolation of additional eleven compounds belonging to triterpens, phenolic compounds and secoiridoids. Among them, elenolic acid ethylester was found to be new compound. Thin Layer Chromatography (TLC), Nuclear magnetic Resonance (NMR) and High Performance Liquid Chromatography - Diode Array Detector (HPLC-DAD) were used for monitoring and evaluation purposes throughout the entire procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Pre-evaluation of metal ions as a catalyst on chemiluminometric sequential injection analysis with luminol-H2O2 system.

    PubMed

    Takayanagi, Toshio; Inaba, Yuya; Kanzaki, Hiroyuki; Jyoichi, Yasutaka; Motomizu, Shoji

    2009-09-15

    Catalytic effect of metal ions on luminol chemiluminescence (CL) was investigated by sequential injection analysis (SIA). The SIA system was set up with two solenoid micropumps, an eight-port selection valve, and a photosensor module with a fountain-type chemiluminescence cell. The SIA system was controlled and the CL signals were collected by a LabVIEW program. Aqueous solutions of luminol, H(2)O(2), and a sample solution containing metal ion were sequentially aspirated to the holding coil, and the zones were immediately propelled to the detection cell. After optimizing the parameters using 1 x 10(-5)M Fe(3+) solution, catalytic effect of some metal species was compared. Among 16 metal species examined, relatively strong CL responses were obtained with Fe(3+), Fe(2+), VO(2+), VO(3)(-), MnO(4)(-), Co(2+), and Cu(2+). The limits of detection by the present SIA system were comparable to FIA systems. Permanganate ion showed the highest CL sensitivity among the metal species examined; the calibration graph for MnO(4)(-) was linear at the concentration level of 10(-8)M and the limit of detection for MnO(4)(-) was 4.0 x 10(-10)M (S/N=3).

  3. Apparatus and method for performing microfluidic manipulations for chemical analysis

    DOEpatents

    Ramsey, J. Michael

    1999-01-01

    A microchip apparatus and method provide fluidic manipulations for a variety of applications, including sample injection for microchip liquid chromatography. The microchip is fabricated using standard photolithographic procedures and chemical wet etching, with the substrate and cover plate joined using direct bonding. Capillary electrophoresis is performed in channels formed in the substrate. Injections are made by electro-osmotically pumping sample through the injection channel that crosses the separation channel, followed by a switching of the potentials to force a plug into the separation channel.

  4. Apparatus and method for performing microfluidic manipulations for chemical analysis

    DOEpatents

    Ramsey, J. Michael

    2002-01-01

    A microchip apparatus and method provide fluidic manipulations for a variety of applications, including sample injection for microchip liquid chromatography. The microchip is fabricated using standard photolitographic procedures and chemical wet etching, with the substrate and cover plate joined using direct bonding. Capillary electrophoresis is performed in channels formed in the substrate. Injections are made by electro-osmotically pumping sample through the injection channel that crosses the separation channel, followed by a switching of the potentials to force a plug into the separation channel.

  5. Determination of isoxaflutole (balance) and its metabolites in water using solid phase extraction followed by high-performance liquid chromatography with ultraviolet or mass spectrometry.

    PubMed

    Lin, Chung-Ho; Lerch, Robert N; Thurman, E Michael; Garrett, Harold E; George, Milon F

    2002-10-09

    Balance (isoxaflutole, IXF) belongs to a new family of herbicides referred to as isoxazoles. IXF has a very short soil half-life (<24 h), degrading to a biologically active diketonitrile (DKN) metabolite that is more polar and considerably more stable. Further degradation of the DKN metabolite produces a nonbiologically active benzoic acid (BA) metabolite. Analytical methods using solid phase extraction followed by high-performance liquid chromatography-UV (HPLC-UV) or high-performance liquid chromatography-mass spectrometry (HPLC-MS) were developed for the analysis of IXF and its metabolites in distilled deionized water and ground water samples. To successfully detect and quantify the BA metabolite by HPLC-UV from ground water samples, a sequential elution scheme was necessary. Using HPLC-UV, the mean recoveries from sequential elution of the parent and its two metabolites from fortified ground water samples ranged from 68.6 to 101.4%. For HPLC-MS, solid phase extraction of ground water samples was performed using a polystyrene divinylbenzene polymer resin. The mean HPLC-MS recoveries of the three compounds from ground water samples spiked at 0.05-2 microg/L ranged from 100.9 to 110.3%. The limits of quantitation for HPLC-UV are approximately 150 ng/L for IXF, 100 ng/L for DKN, and 250 ng/L for BA. The limit of quantitation by HPLC-MS is 50 ng/L for each compound. The methods developed in this work can be applied to determine the transport and fate of Balance in the environment.

  6. Comparative analysis of monoclonal antibody N-glycosylation using stable isotope labelling and UPLC-fluorescence-MS.

    PubMed

    Millán Martín, Silvia; Delporte, Cédric; Farrell, Amy; Navas Iglesias, Natalia; McLoughlin, Niaobh; Bones, Jonathan

    2015-03-07

    A twoplex method using (12)C6 and (13)C6 stable isotope analogues (Δmass = 6 Da) of 2-aminobenzoic acid (2-AA) is described for quantitative analysis of N-glycans present on monoclonal antibodies and other glycoproteins using ultra performance liquid chromatography with sequential fluorescence and accurate mass tandem quadrupole time of flight (QToF) mass spectrometric detection.

  7. Crocheted ETFE-reactor for on-line post-column photoderivatization of diclofenac in high-performance liquid chromatography.

    PubMed

    Kuhlmann, O; Krauss, G J

    1997-12-01

    A sensitive and selective bioanalytical method for diclofenac using reversed-phase HPLC and fluorescence detection is described. Diclofenac was detected as its fluorescent derivative after on-line post-column photoderivatization. Irradiation with UV light of diclofenac in aqueous solutions leads to the sequential loss of both chlorine substituents and ring closure. The major product, carbazole-1-acetic acid, was detected by a fluorescence detector using an excitation wavelength of 286 nm and an emission wavelength of 360 nm. The self-made reactor was a crocheted ethylene and tetrafluoroethylene (ETFE, named TEFZEL) capillary, 20 m in length, wound directly around a 253.7 nm UV lamp. The capillary was crocheted in order to overcome peak widening. Chromatographic separation was achieved by using a Regis SPS 100 RP-8 column (5 microm; 150 mm x 4.6 mm i.d.) and a LiChrospher 100 RP-18 (5 microm) guard column from E. Merck. The detection limit was 1 ng ml(-1) at an injection volume of 20 microl. Daily relative standard deviations (RSD) were 5.5%, (73 ng diclofenac/ml, n = 9), and 5.1% (405 ng diclofenac/ml, n = 6), respectively. Chromatograms of human aqueous humor and human serum containing diclofenac, and figures showing the time dependent increase/decrease of the photoderivatization product, are shown.

  8. Microcellular injection molding process for producing lightweight thermoplastic polyurethane with customizable properties

    NASA Astrophysics Data System (ADS)

    Ellingham, Thomas; Kharbas, Hrishikesh; Manitiu, Mihai; Scholz, Guenter; Turng, Lih-Sheng

    2018-03-01

    A three-stage molding process involving microcellular injection molding with core retraction and an "out-of-mold" expansion was developed to manufacture thermoplastic polyurethane into lightweight foams of varying local densities, microstructures, and mechanical properties in the same microcellular injection molded part. Two stages of cavity expansion through sequential core retractions and a third expansion in a separate mold at an elevated temperature were carried out. The densities varied from 0.25 to 0.42 g/cm3 (77% to 62% weight reduction). The mechanical properties varied as well. Cyclic compressive strengths and hysteresis loss ratios, together with the microstructures, were characterized and reported.

  9. Efficient spin-current injection in single-molecule magnet junctions

    NASA Astrophysics Data System (ADS)

    Xie, Haiqing; Xu, Fuming; Jiao, Hujun; Wang, Qiang; Liang, J.-Q.

    2018-01-01

    We study theoretically spin transport through a single-molecule magnet (SMM) in the sequential and cotunneling regimes, where the SMM is weakly coupled to one ferromagnetic and one normal-metallic leads. By a master-equation approach, it is found that the spin polarization injected from the ferromagnetic lead is amplified and highly polarized spin-current can be generated, due to the exchange coupling between the transport electron and the anisotropic spin of the SMM. Moreover, the spin-current polarization can be tuned by the gate or bias voltage, and thus an efficient spin injection device based on the SMM is proposed in molecular spintronics.

  10. Development and Validation of a Fast Procedure to Analyze Amoxicillin in River Waters by Direct-Injection LC-MS/MS

    ERIC Educational Resources Information Center

    Homem, Vera; Alves, Arminda; Santos, Lu´cia

    2014-01-01

    A laboratory application with a strong component in analytical chemistry was designed for undergraduate students, in order to introduce a current problem in the environmental science field, the water contamination by antibiotics. Therefore, a simple and rapid method based on direct injection and high performance liquid chromatography-tandem mass…

  11. Automation of flow injection gas diffusion-ion chromatography for the nanomolar determination of methylamines and ammonia in seawater and atmospheric samples

    PubMed Central

    Gibb, Stuart W.; Wood, John W.; Fauzi, R.; Mantoura, C.

    1995-01-01

    The automation and improved design and performance of Flow Injection Gas Diffusion-Ion Chromatography (FIGD-IC), a novel technique for the simultaneous analysis of trace ammonia (NH3) and methylamines (MAs) in aqueous media, is presented. Automated Flow Injection Gas Diffusion (FIGD) promotes the selective transmembrane diffusion of MAs and NH3 from aqueous sample under strongly alkaline (pH > 12, NaOH), chelated (EDTA) conditions into a recycled acidic acceptor stream. The acceptor is then injected onto an ion chromatograph where NH3 and the MAs are fully resolved as their cations and detected conductimetrically. A versatile PC interfaced control unit and data capture unit (DCU) are employed in series to direct the selonoid valve switching sequence, IC operation and collection of data. Automation, together with other modifications improved both linearily (R2 > 0.99 MAs 0-100 nM, NH3 0-1000 nM) and precision (<8%) of FIGD-IC at nanomolar concentrations, compared with the manual procedure. The system was successfully applied to the determination of MAs and NH3 in seawater and in trapped particulate and gaseous atmospheric samples during an oceanographic research cruise. PMID:18925047

  12. Dual cloud point extraction coupled with hydrodynamic-electrokinetic two-step injection followed by micellar electrokinetic chromatography for simultaneous determination of trace phenolic estrogens in water samples.

    PubMed

    Wen, Yingying; Li, Jinhua; Liu, Junshen; Lu, Wenhui; Ma, Jiping; Chen, Lingxin

    2013-07-01

    A dual cloud point extraction (dCPE) off-line enrichment procedure coupled with a hydrodynamic-electrokinetic two-step injection online enrichment technique was successfully developed for simultaneous preconcentration of trace phenolic estrogens (hexestrol, dienestrol, and diethylstilbestrol) in water samples followed by micellar electrokinetic chromatography (MEKC) analysis. Several parameters affecting the extraction and online injection conditions were optimized. Under optimal dCPE-two-step injection-MEKC conditions, detection limits of 7.9-8.9 ng/mL and good linearity in the range from 0.05 to 5 μg/mL with correlation coefficients R(2) ≥ 0.9990 were achieved. Satisfactory recoveries ranging from 83 to 108% were obtained with lake and tap water spiked at 0.1 and 0.5 μg/mL, respectively, with relative standard deviations (n = 6) of 1.3-3.1%. This method was demonstrated to be convenient, rapid, cost-effective, and environmentally benign, and could be used as an alternative to existing methods for analyzing trace residues of phenolic estrogens in water samples.

  13. Dispersive liquid-liquid microextraction for the determination of nitrophenols in soils by microvial insert large volume injection-gas chromatography-mass spectrometry.

    PubMed

    Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M

    2016-07-22

    A rapid and sensitive procedure for the determination of six NPs in soils by gas chromatography and mass spectrometry (GC-MS) is proposed. Ultrasound assisted extraction (UAE) is used for NP extraction from soil matrices to an organic solvent, while the environmentally friendly technique dispersive liquid-liquid microextraction (DLLME) is used for the preconcentration of the resulting UAE extracts. NPs were derivatized by applying an "in-situ" acetylation procedure, before being injected into the GC-MS system using microvial insert large volume injection (LVI). Several parameters affecting UAE, DLLME, derivatization and injection steps were investigated. The optimized procedure provided recoveries of 86-111% from spiked samples. Precision values of the procedure (expressed as relative standard deviation, RSD) lower than 12%, and limits of quantification ranging from 1.3 to 2.6ngg(-1), depending on the compound, were obtained. Twenty soil samples, obtained from military, industrial and agricultural areas, were analyzed by the proposed method. Two of the analytes were quantified in two of the samples obtained from industrial areas, at concentrations in the 4.8-9.6ngg(-1) range. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Effectiveness of leukocyte immunotherapy in primary recurrent spontaneous abortion (RSA).

    PubMed

    Gharesi-Fard, Behrouz; Zolghadri, Jaleh; Foroughinia, Leila; Tavazoo, Fahimeh; Samsami Dehaghani, Alamtaj

    2007-09-01

    Recurrent spontaneous abortion (RSA) is defined as three or more sequential abortions before the twentieth week of gestation. There are evidences to support an allo-immunologic mechanism for RSA. One of the methods for treatment of RSA is leukocyte therapy; however there is still controversy about effectiveness of this method. To evaluate the effectiveness of leukocyte therapy for treatment of RSA. Ninety two non-pregnant women with at least three sequential abortions (60 primary & 32 secondary aborters) recognized as RSA were referred to our Laboratory for immunotherapy. All the cases were immunized by isolated lymphocytes from their husbands. Fifty to 100 million washed and resuspended mononuclear cells were injected by I.V., S.C., and I.D. route. The result of each injection was checked by WBC cross matching between couples after four weeks of injections. Immunization was repeated in fifth week to a maximum of 3 times if needed. Eighty one age-matched non-pregnant RSA women (52 primary and 29 secondary aborters) with at least three sequential abortions were also included in this study as controls. The control group was not immunized. 67 out of 92 (72.8%) immunized cases and 44 out of 81 controls (54.3%) showed a successful outcome of pregnancy (p<0.02). Comparison of primary and secondary aborters indicated a significantly better outcome only in primary (75% vs. 42.3%. p<0.001) but not in secondary aborters (68.8% vs. 75.9%, p = 0.7). The present investigation showed the effectiveness of leukocyte therapy in primary but not in secondary RSA patients. Despite the current controversy and limitation of leukocyte therapy in RSA, the results of our investigation provide evidence supporting the use of allo-immunization in improving the outcome of pregnancy in primary RSA patients.

  15. Simultaneous determination of rutin and ascorbic acid in a sequential injection lab-at-valve system.

    PubMed

    Al-Shwaiyat, Mohammed Khair E A; Miekh, Yuliia V; Denisenko, Tatyana A; Vishnikin, Andriy B; Andruch, Vasil; Bazel, Yaroslav R

    2018-02-05

    A green, simple, accurate and highly sensitive sequential injection lab-at-valve procedure has been developed for the simultaneous determination of ascorbic acid (Asc) and rutin using 18-molybdo-2-phosphate Wells-Dawson heteropoly anion (18-MPA). The method is based on the dependence of the reaction rate between 18-MPA and reducing agents on the solution pH. Only Asc is capable of interacting with 18-MPA at pH 4.7, while at pH 7.4 the reaction with both Asc and rutin proceeds simultaneously. In order to improve the precision and sensitivity of the analysis, to minimize reagent consumption and to remove the Schlieren effect, the manifold for the sequential injection analysis was supplemented with external reaction chamber, and the reaction mixture was segmented. By the reduction of 18-MPA with reducing agents one- and two-electron heteropoly blues are formed. The fraction of one-electron heteropoly blue increases at low concentrations of the reducer. Measurement of the absorbance at a wavelength corresponding to the isobestic point allows strictly linear calibration graphs to be obtained. The calibration curves were linear in the concentration ranges of 0.3-24mgL -1 and 0.2-14mgL -1 with detection limits of 0.13mgL -1 and 0.09mgL -1 for rutin and Asc, respectively. The determination of rutin was possible in the presence of up to a 20-fold molar excess of Asc. The method was applied to the determination of Asc and rutin in ascorutin tablets with acceptable accuracy and precision (1-2%). Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Miniaturizing and automation of free acidity measurements for uranium (VI)-HNO3 solutions: Development of a new sequential injection analysis for a sustainable radio-analytical chemistry.

    PubMed

    Néri-Quiroz, José; Canto, Fabrice; Guillerme, Laurent; Couston, Laurent; Magnaldo, Alastair; Dugas, Vincent

    2016-10-01

    A miniaturized and automated approach for the determination of free acidity in solutions containing uranium (VI) is presented. The measurement technique is based on the concept of sequential injection analysis with on-line spectroscopic detection. The proposed methodology relies on the complexation and alkalimetric titration of nitric acid using a pH 5.6 sodium oxalate solution. The titration process is followed by UV/VIS detection at 650nm thanks to addition of Congo red as universal pH indicator. Mixing sequence as well as method validity was investigated by numerical simulation. This new analytical design allows fast (2.3min), reliable and accurate free acidity determination of low volume samples (10µL) containing uranium/[H(+)] moles ratio of 1:3 with relative standard deviation of <7.0% (n=11). The linearity range of the free nitric acid measurement is excellent up to 2.77molL(-1) with a correlation coefficient (R(2)) of 0.995. The method is specific, presence of actinide ions up to 0.54molL(-1) does not interfere on the determination of free nitric acid. In addition to automation, the developed sequential injection analysis method greatly improves the standard off-line oxalate complexation and alkalimetric titration method by reducing thousand fold the required sample volume, forty times the nuclear waste per analysis as well as the analysis time by eight fold. These analytical parameters are important especially in nuclear-related applications to improve laboratory safety, personnel exposure to radioactive samples and to drastically reduce environmental impacts or analytical radioactive waste. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. The CE way of thinking: "all is relative!".

    PubMed

    Schmitt-Kopplin, Philippe; Fekete, Agnes

    2008-01-01

    Over the last two decades, the development of capillary electrophoresis (CE) instruments has lead to systems with programmable samplers, separation columns, separation buffers, and detection devices comparable visually in many aspects to the setup of classical chromatography. Two characteristics make CE essentially different from chromatography and are the basis of the CE way of thinking: first is the injection type and the liquid flow within the capillary. When the injection is made hydrodynamically (such as in most of the applications found in the literature), the injected volumes are directly dependent on the type and size of the separation capillary. The second characteristic is that in CE, buffer velocity is not pressure-driven, as in liquid chromatography, but is electrokinetically governed by the quality of the capillary surface (separation buffer dependent surface charge) inducing an electroosmotic flow (EOF). The EOF undergoes small variations and is not necessarily identical from one separation or day to the other. The direct consequence is that the migration time of the analytes apparently nonreproducible, although the velocity of the ions is the same. The effective mobility (field strength normalized velocity) of the ions is a possible parameterization from acquired time-scale to effective mobility-scale electropherograms leading to a reproducible visualization and better quantification with a direct relation to structural characters of the analytes (i.e., charge and size; see Chapter 23).

  18. Injection order effects on efficacy of calcium chloride and sodium tripolyphosphate in controlling the pink color defect in uncured, intact turkey breast.

    PubMed

    Claus, James R; Sawyer, Christopher A; Vogel, Kurt D

    2010-04-01

    An experiment was conducted to test sequential injection of sodium tripolyphosphate (STP; 0.5% meat weight basis, mwb) followed by injection with or without addition of calcium chloride (CaCl(2), 500 ppm mwb), and to test the effect of post-injection delay prior to cooking. A second experiment evaluated the impact of injection order and delay time between independent addition of CaCl(2) (500 ppm mwb) and STP (0.5% mwb). Turkey was formulated without an added pink generating ligand (NONE), with nicotinamide (NIC; 0.1% mwb), or with sodium nitrite (NIT; 10 ppm mwb). A white colloid was observed in the extracellular space of treatments containing both STP and CaCl(2.) Addition of CaCl(2) decreased nitrosylhemochrome but did not reduce levels of nicotinamide hemochrome or CIE a(*) values. Injection order or delay between injections did not contribute to controlling the pink defect in cooked, intact turkey breast. Published by Elsevier Ltd.

  19. Immunogenicity of simultaneous versus sequential administration of a 23-valent pneumococcal polysaccharide vaccine and a quadrivalent influenza vaccine in older individuals: A randomized, open-label, non-inferiority trial.

    PubMed

    Nakashima, Kei; Aoshima, Masahiro; Ohfuji, Satoko; Yamawaki, Satoshi; Nemoto, Masahiro; Hasegawa, Shinya; Noma, Satoshi; Misawa, Masafumi; Hosokawa, Naoto; Yaegashi, Makito; Otsuka, Yoshihito

    2018-03-21

    It is unclear whether simultaneous administration of a 23-valent pneumococcal polysaccharide vaccine (PPSV23) and a quadrivalent influenza vaccine (QIV) produces immunogenicity in older individuals. This study tested the hypothesis that the pneumococcal antibody response elicited by simultaneous administration of PPSV23 and QIV in older individuals is not inferior to that elicited by sequential administration of PPSV23 and QIV. We performed a single-center, randomized, open-label, non-inferiority trial comprising 162 adults aged ≥65 years randomly assigned to either the simultaneous (simultaneous injections of PPSV23 and QIV) or sequential (control; PPSV23 injected 2 weeks after QIV vaccination) groups. Pneumococcal immunoglobulin G (IgG) titers of serotypes 23F, 3, 4, 6B, 14, and 19A were assessed. The primary endpoint was the serotype 23F response rate (a ≥2-fold increase in IgG concentrations 4-6 weeks after PPSV23 vaccination). With the non-inferiority margin set at 20% fewer patients, the response rate of serotype 23F in the simultaneous group (77.8%) was not inferior to that of the sequential group (77.6%; difference, 0.1%; 90% confidence interval, -10.8% to 11.1%). None of the pneumococcal IgG serotype titers were significantly different between the groups 4-6 weeks after vaccination. Simultaneous administration did not show a significant decrease in seroprotection odds ratios for H1N1, H3N2, or B/Phuket influenza strains other than B/Texas. Additionally, simultaneous administration did not increase adverse reactions. Hence, simultaneous administration of PPSV23 and QIV shows an acceptable immunogenicity that is comparable to sequential administration without an increase in adverse reactions. (This study was registered with ClinicalTrials.gov [NCT02592486]).

  20. Visual detection and sequential injection determination of aluminium using a cinnamoyl derivative.

    PubMed

    Elečková, Lenka; Alexovič, Michal; Kuchár, Juraj; Balogh, Ioseph S; Andruch, Vasil

    2015-02-01

    A cinnamoyl derivative, 3-[4-(dimethylamino)cinnamoyl]-4-hydroxy-6-methyl-3,4-2H-pyran-2-one, was used as a ligand for the determination of aluminium. Upon the addition of an acetonitrile solution of the ligand to an aqueous solution containing Al(III) and a buffer solution at pH 8, a marked change in colour from yellow to orange is observed. The colour intensity is proportional to the concentration of Al(III); thus, the 'naked-eye' detection of aluminium is possible. The reaction is also applied for sequential injection determination of aluminium. Beer׳s law is obeyed in the range from 0.055 to 0.66 mg L(-1) of Al(III). The limit of detection, calculated as three times the standard deviation of the blank test (n=10), was found to be 4 μg L(-1) for Al(III). The method was applied for the determination of aluminium in spiked water samples and pharmaceutical preparations. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Determination of iodopropynyl butylcarbamate in cosmetic formulations utilizing pulsed splitless injection, gas chromatography with electron capture detector.

    PubMed

    Palmer, Kevin B; LaFon, William; Burford, Mark D

    2017-09-22

    Current analytical methodology for iodopropynyl butylcarbamate (IPBC) analysis focuses on the use of liquid chromatography and mass spectrometer (LC-MS), but the high instrumentation and operator investment required has resulted in the need for a cost effective alternative methodology. Past publications investigating gas chromatography with electron capture detector (GC-ECD) for IPBC quantitation proved largely unsuccessful, likely due to the preservatives limited thermal stability. The use of pulsed injection techniques commonly used for trace analysis of thermally labile pharmaceutical compounds was successfully adapted for IPBC analysis and utilizes the selectivity of GC-ECD analysis. System optimization and sample preparation improvements resulted in substantial performance and reproducibility gains. Cosmetic formulations preserved with IPBC (50-100ppm) were solvated in toluene/isopropyl alcohol and quantified over the 0.3-1.3μg/ml calibration range. The methodology was robust (relative standard deviation 4%), accurate (98% recovery), and sensitive (limit of detection 0.25ng/ml) for use in routine testing of cosmetic formulation preservation. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Ionic liquid and aqueous two-phase extraction based on salting-out coupled with high-performance liquid chromatography for the determination of seven rare ginsenosides in Xue-Sai-Tong injection.

    PubMed

    Li, Lan-Jie; Jin, Yong-Ri; Wang, Xiao-Zhong; Liu, Ying; Wu, Qian; Shi, Xiao-Lei; Li, Xu-Wen

    2015-09-01

    A method of ionic liquid salt aqueous two-phase extraction coupled with high-performance liquid chromatography has been developed for the analysis of seven rare ginsenosides including Rg6 , F4 , 20(S)-Rg3 , 20(R)-Rg3 , Rk3 , Rk1 , and Rg5 in Xue-Sai-Tong injection. The injection was mixed with ionic liquid 1-butyl-3-methylimidazolium bromide aqueous solution, and a mixture was obtained. With the addition of sodium dodecyl sulfate and dipotassium phosphate into the mixture, the aqueous two-phase mixture was formed after ultrasonic treatment and centrifuged. Rare ginsenosides were extracted into the upper phase. To obtain a high extraction factors, various influences were considered systematically, such as the volume of ionic liquid, the category and amount of salts, the amount of sodium dodecyl sulfate, the pH value of system, and the time of ultrasonic treatment. Under the optimal condition, rare ginsenosides in Xue-Sai-Tong injection were enriched and detected, the recoveries of seven rare ginsenosides ranged from 90.05 to 112.55%, while relative standard deviations were lower than 2.50%. The developed method was reliable, rapid and sensitive for the determination of seven rare ginsenosides in the injections. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Single column comprehensive analysis of pharmaceutical preparations using dual-injection mixed-mode (ion-exchange and reversed-phase) and hydrophilic interaction liquid chromatography.

    PubMed

    Kazarian, Artaches A; Taylor, Mark R; Haddad, Paul R; Nesterenko, Pavel N; Paull, Brett

    2013-12-01

    The comprehensive separation and detection of hydrophobic and hydrophilic active pharmaceutical ingredients (APIs), their counter-ions (organic, inorganic) and excipients, using a single mixed-mode chromatographic column, and a dual injection approach is presented. Using a mixed-mode Thermo Fisher Acclaim Trinity P1 column, APIs, their counter-ions and possible degradants were first separated using a combination of anion-exchange, cation-exchange and hydrophobic interactions, using a mobile phase consisting of a dual organic modifier/salt concentration gradient. A complementary method was also developed using the same column for the separation of hydrophilic bulk excipients, using hydrophilic interaction liquid chromatography (HILIC) under high organic solvent mobile phase conditions. These two methods were then combined within a single gradient run using dual sample injection, with the first injection at the start of the applied gradient (mixed-mode retention of solutes), followed by a second sample injection at the end of the gradient (HILIC retention of solutes). Detection using both ultraviolet absorbance and refractive index enabled the sensitive detection of APIs and UV-absorbing counter-ions, together with quantitative determination of bulk excipients. The developed approach was applied successfully to the analysis of a dry powder inhalers (Flixotide(®), Spiriva(®)), enabling comprehensive quantification of all APIs and excipients in the sample. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. A novel liquid chromatography Orbitrap mass spectrometry method with full scan for simultaneous determination of multiple bioactive constituents of Shenkang injection in rat tissues: Application to tissue distribution and pharmacokinetic studies.

    PubMed

    Yang, Jie; Sun, Zhi; Li, Duolu; Duan, Fei; Li, Zhuolun; Lu, Jingli; Shi, Yingying; Xu, Tanye; Zhang, Xiaojian

    2018-06-07

    Shenkang injection is a traditional Chinese formula with good curative effect on chronic renal failure. In this paper, a novel, rapid and sensitive ultra high performance liquid chromatography coupled with Q Exactive hybrid quadrupole orbitrap high resolution accurate mass spectrometry was developed and validated for simultaneous determination of seven bioactive constituents of Shenkang injection in rat plasma and tissues after intravenous administration. Acetonitrile was used as protein precipitation agent in biological samples dispose with carbamazepine as internal standard. The chromatographic separation was carried out on a C 18 column with a gradient mobile phase consisting of acetonitrile and water (containing 0.1% formic acid). The MS analysis was performed in the full scan positive and negative ion mode. The lower limits of quantification for the seven analytes in rat plasma and tissues were 0.1-10 ng/mL. The validated method was successfully applied to tissue distribution and pharmacokinetic studies of Shenkang injection after intravenous administration. The results of the tissue distribution study showed that the high concentration of seven constituents were primarily in the kidney tract. This is the first time to report the application of Q-Orbitrap with full scan mass spectrometry in tissue distribution and pharmacokinetic studies of Shenkang injection. This article is protected by copyright. All rights reserved.

  5. Use of Protein G Microcolumns in Chromatographic Immunoassays: A Comparison of Competitive Binding Formats

    PubMed Central

    Pfaunmiller, Erika L.; Anguizola, Jeanethe A.; Milanuk, Mitchell L.; Carter, NaTasha; Hage, David S.

    2016-01-01

    Affinity microcolumns containing protein G were used as general platforms for creating chromatographic-based competitive binding immunoassays. Human serum albumin (HSA) was used as a model target for this work and HSA tagged with a near infrared fluorescent dye was utilized as the label. The protein G microcolumns were evaluated for use in several assay formats, including both solution-based and column-based competitive binding immunoassays and simultaneous or sequential injection formats. All of these methods were characterized by using the same amounts of labeled HSA and anti-HSA antibodies per sample, as chosen for the analysis of a protein target in the low-to-mid ng/mL range. The results were used to compare these formats in terms of their response, precision, limits of detection, and analysis time. All these methods gave detection limits in the range of 8–19 ng/mL and precisions ranging from ± 5% to ± 10% when using an injection flow rate of 0.10 mL/min. The column-based sequential injection immunoassay provided the best limit of detection and the greatest change in response at low target concentrations, while the solution-based simultaneous injection method had the broadest linear and dynamic ranges. These results provided valuable guidelines that can be employed to develop and extend the use of protein G microcolumns and these competitive binding formats to other protein biomarkers or biological agents of clinical or pharmaceutical interest. PMID:26777776

  6. Time-lapse evaluation of human embryo development in single versus sequential culture media--a sibling oocyte study.

    PubMed

    Ciray, Haydar Nadir; Aksoy, Turan; Goktas, Cihan; Ozturk, Bilgen; Bahceci, Mustafa

    2012-09-01

    To compare the dynamics of early development between embryos cultured in single and sequential media. Randomized, comparative study. Private IVF centre. A total of 446 metaphase II oocytes from 51 couples who underwent oocyte retrieval procedure for intracytoplasmic sperm injection. Forty-nine resulted in embryo transfer. Oocytes were split between single and sequential media produced by the same manufacturer and cultured in a time-lapse incubator. Morphokinetic parameters until the embryos reached the 5-cell stage (t5), utilization, clinical pregnancy and implantation rates. Embryos cultured in single media were advanced from the first mitosis cycle and reached 2- to 5-cell stages earlier. There was not any difference between the durations for cell cycle two (cc2 = t3-t2) and s2 (t4-t3). The utilization, clinical pregnancy and implantation rates did not differ between groups. The proportion of cryopreserved day 6 embryos to two pronuclei oocytes was significantly higher in sequential than in single media. Morphokinetics of embryo development vary between single and sequential culture media at least until the 5-cell stage. The overall clinical and embryological parameters remain similar regardless of the culture system.

  7. A fatal case of systemic fat embolism resulting from gluteal injections of vitamin e for cosmetic enhancement.

    PubMed

    Mendoza-Morales, R C; Camberos-Nava, E V; Luna-Rosas, A; Garcés-Ramírez, L; De la Cruz, F; García-Dolores, F

    2016-02-01

    Recently in Mexico the number of cosmetic surgeries has increased. These procedures are often carried out by unqualified people using obsolete and contraindicated products such as injectable oil, which cause uncorrectable disfigurement or more serious complications, even death, after reaching the systemic circulation. We report the case of a fat embolism syndrome (FES) caused by injections of vitamin E (tocopherol) in order to increase the volume of the buttocks. This case of a FES caused by injections of vitamin E was confirmed by gas chromatography coupled to mass spectrometry. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. A METHOD FOR AUTOMATED ANALYSIS OF 10 ML WATER SAMPLES CONTAINING ACIDIC, BASIC, AND NEUTRAL SEMIVOLATILE COMPOUNDS LISTED IN USEPA METHOD 8270 BY SOLID PHASE EXTRACTION COUPLED IN-LINE TO LARGE VOLUME INJECTION GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    Data is presented showing the progress made towards the development of a new automated system combining solid phase extraction (SPE) with gas chromatography/mass spectrometry for the single run analysis of water samples containing a broad range of acid, base and neutral compounds...

  9. Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensor.

    PubMed

    Saetear, Phoonthawee; Khamtau, Kittiwut; Ratanawimarnwong, Nuanlaor; Sereenonchai, Kamonthip; Nacapricha, Duangjai

    2013-10-15

    This work presents the simultaneous determination of sucrose and phosphate by using sequential injection (SI) system with a low cost paired emitter-detector diode (PEDD) light sensor. The PEDD uses two 890 nm LEDs. Measurement of sucrose in Brix unit was carried out based on the detection of light refraction occurring at the liquid interface (the schlieren effect) between the sucrose solution and water. Phosphate was measured from the formation of calcium phosphate with turbidimetric detection. With careful design of the loading sequence and volume (sample--precipitating reagent--sample), simultaneous detection of sucrose and phosphate was accomplished with the single PEDD detector. At the optimized condition, linear calibrations from 1 to 7 Brix sucrose and from 50 to 200mg PO4(3-)L(-1) were obtained. Good precision at lower than 2% RSD (n=10) for both analytes with satisfactory throughput of 21 injections h(-1) was achieved. The method was successfully applied for the determination of sucrose and phosphate in cola drinks. The proposed method is readily applicable for automation and is found to be an alternative method to conventional procedures for on-line quality control process in cola drink industry. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  10. Development of a 3-step straight-through purification strategy combining membrane adsorbers and resins.

    PubMed

    Hughson, Michael D; Cruz, Thayana A; Carvalho, Rimenys J; Castilho, Leda R

    2017-07-01

    The pressures to efficiently produce complex biopharmaceuticals at reduced costs are driving the development of novel techniques, such as in downstream processing with straight-through processing (STP). This method involves directly and sequentially purifying a particular target with minimal holding steps. This work developed and compared six different 3-step STP strategies, combining membrane adsorbers, monoliths, and resins, to purify a large, complex, and labile glycoprotein from Chinese hamster ovary cell culture supernatant. The best performing pathway was cation exchange chromatography to hydrophobic interaction chromatography to affinity chromatography with an overall product recovery of up to 88% across the process and significant clearance of DNA and protein impurities. This work establishes a platform and considerations for the development of STP of biopharmaceutical products and highlights its suitability for integration with single-use technologies and continuous production methods. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:931-940, 2017. © 2017 American Institute of Chemical Engineers.

  11. Semi-automated hydrophobic interaction chromatography column scouting used in the two-step purification of recombinant green fluorescent protein.

    PubMed

    Stone, Orrin J; Biette, Kelly M; Murphy, Patrick J M

    2014-01-01

    Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in development other of HIC-compatible protein purification schemes.

  12. Sequential determination of fat- and water-soluble vitamins in Rhodiola imbricata root from trans-Himalaya with rapid resolution liquid chromatography/tandem mass spectrometry.

    PubMed

    Tayade, Amol B; Dhar, Priyanka; Kumar, Jatinder; Sharma, Manu; Chaurasia, Om P; Srivastava, Ravi B

    2013-07-30

    A rapid method was developed to determine both types of vitamins in Rhodiola imbricata root for the accurate quantification of free vitamin forms. Rapid resolution liquid chromatography/tandem mass spectrometry (RRLC-MS/MS) with electrospray ionization (ESI) source operating in multiple reactions monitoring (MRM) mode was optimized for the sequential analysis of nine water-soluble vitamins (B1, B2, two B3 vitamins, B5, B6, B7, B9, and B12) and six fat-soluble vitamins (A, E, D2, D3, K1, and K2). Both types of vitamins were separated by ion-suppression reversed-phase liquid chromatography with gradient elution within 30 min and detected in positive ion mode. Deviations in the intra- and inter-day precision were always below 0.6% and 0.3% for recoveries and retention time. Intra- and inter-day relative standard deviation (RSD) values of retention time for water- and fat-soluble vitamin were ranged between 0.02-0.20% and 0.01-0.15%, respectively. The mean recoveries were ranged between 88.95 and 107.07%. Sensitivity and specificity of this method allowed the limits of detection (LOD) and limits of quantitation (LOQ) of the analytes at ppb levels. The linear range was achieved for fat- and water-soluble vitamins at 100-1000 ppb and 10-100 ppb. Vitamin B-complex and vitamin E were detected as the principle vitamins in the root of this adaptogen which would be of great interest to develop novel foods from the Indian trans-Himalaya. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. High Performance Liquid Chromatography

    NASA Astrophysics Data System (ADS)

    Talcott, Stephen

    High performance liquid chromatography (HPLC) has many applications in food chemistry. Food components that have been analyzed with HPLC include organic acids, vitamins, amino acids, sugars, nitrosamines, certain pesticides, metabolites, fatty acids, aflatoxins, pigments, and certain food additives. Unlike gas chromatography, it is not necessary for the compound being analyzed to be volatile. It is necessary, however, for the compounds to have some solubility in the mobile phase. It is important that the solubilized samples for injection be free from all particulate matter, so centrifugation and filtration are common procedures. Also, solid-phase extraction is used commonly in sample preparation to remove interfering compounds from the sample matrix prior to HPLC analysis.

  14. Injection port derivatization following ion-pair hollow fiber-protected liquid-phase microextraction for determining acidic herbicides by gas chromatography/mass spectrometry.

    PubMed

    Wu, Jingming; Lee, Hian Kee

    2006-10-15

    Injection port derivatization following ion-pair hollow fiber-protected liquid-phase microextraction (LPME) for the trace determination of acidic herbicides (2,4-dichlorobenzoic acid, 2,4-dichlorophenoxyacetic acid, 2-(2,4-dichlorophenoxy)propionic acid, 3,5-dichlorobenzoic acid, 2-(2,4,5-trichlorophenoxy)propionic acid) in aqueous samples by gas chromatography/mass spectrometry (GC/MS) was developed. Prior to GC injection port derivatization, acidic herbicides were converted into their ion-pair complexes with tetrabutylammonium chloride in aqueous samples and then extracted by 1-octanol impregnated in the hollow fiber. Upon injection, ion pairs of acidic herbicides were quantitatively derivatized to their butyl esters in the GC injection port. Thus, several parameters related to the derivatization process (i.e., injection temperature, purge-off time) were evaluated, and main parameters affecting the hollow fiber-protected LPME procedure such as extraction organic solvent, ion-pair reagent type, pH of aqueous medium, concentration of ion-pair reagent, sodium chloride concentration added to the aqueous medium, stirring speed, and extraction time profile, optimized. At the selected extraction and derivatization conditions, no matrix effects were observed. This method proved good repeatability (RSDs <12.3%, n = 6) and good linearity (r2 > or = 0.9939) for spiked deionized water samples for five analytes. The limits of detection were in the range of 0.51-13.7 ng x L(-1) (S/N =3) under GC/MS selected ion monitoring mode. The results demonstrated that injection port derivatization following ion-pair hollow fiber-protected LPME was a simple, rapid, and accurate method for the determination of trace acidic herbicides from aqueous samples. In addition, this method proved to be environmentally friendly since it completely avoided open derivatization with potentially hazardous reagents.

  15. Multiple injection mode with or without repeated sample injections: Strategies to enhance productivity in countercurrent chromatography.

    PubMed

    Müller, Marco; Wasmer, Katharina; Vetter, Walter

    2018-06-29

    Countercurrent chromatography (CCC) is an all liquid based separation technique typically used for the isolation and purification of natural compounds. The simplicity of the method makes it easy to scale up CCC separations from analytical to preparative and even industrial scale. However, scale-up of CCC separations requires two different instruments with varying coil dimensions. Here we developed two variants of the CCC multiple injection mode as an alternative to increase the throughput and enhance productivity of a CCC separation when using only one instrument. The concept is based on the parallel injection of samples at different points in the CCC column system and the simultaneous separation using one pump only. The wiring of the CCC setup was modified by the insertion of a 6-port selection valve, multiple T-pieces and sample loops. Furthermore, the introduction of storage sample loops enabled the CCC system to be used with repeated injection cycles. Setup and advantages of both multiple injection modes were shown by the isolation of the furan fatty acid 11-(3,4-dimethyl-5-pentylfuran-2-yl)-undecanoic acid (11D5-EE) from an ethyl ester oil rich in 4,7,10,13,16,19-docosahexaenoic acid (DHA-EE). 11D5-EE was enriched in one step from 1.9% to 99% purity. The solvent consumption per isolated amount of analyte could be reduced by ∼40% compared to increased throughput CCC and by ∼5% in the repeated multiple injection mode which also facilitated the isolation of the major compound (DHA-EE) in the sample. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Electropolymerized fluorinated aniline-based fiber for headspace solid-phase microextraction and gas chromatographic determination of benzaldehyde in injectable pharmaceutical formulations.

    PubMed

    Mohammadi, Ali; Mohammadi, Somayeh; Bayandori Moghaddam, Abdolmajid; Masoumi, Vahideh; Walker, Roderick B

    2014-10-01

    In this study, a simple method was developed and validated to detect trace levels of benzaldehyde in injectable pharmaceutical formulations by solid-phase microextraction coupled with gas chromatography-flame ionization detector. Polyaniline was electrodeposited on a platinum wire in trifluoroacetic acid solvent by cyclic voltammetry technique. This fiber shows high thermal and mechanical stability and high performance in extraction of benzaldehyde. Extraction and desorption time and temperature, salt effect and gas chromatography parameters were optimized as key parameters. At the optimum conditions, the fiber shows good linearity between peak area ratio of benzaldehyde/3-chlorobenzaldehyde and benzaldehyde concentration in the range of 50-800 ng/mL with percent relative standard deviation values ranging from 0.75 to 8.64% (n = 3). The limits of quantitation and detection were 50 and 16 ng/mL, respectively. The method has the requisite selectivity, sensitivity, accuracy and precision to assay benzaldehyde in injectable pharmaceutical dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Separation and determination of estrogen in the water environment by high performance liquid chromatography-fourier transform infrared spectroscopy

    PubMed Central

    Zheng, Bei; Li, Wentao; Li, Hongyan; Liu, Lin; Lei, Pei; Ge, Xiaopeng; Yu, Zhiyong; Zhou, Yiqi

    2016-01-01

    The components for connecting high-performance liquid chromatography (HPLC) with Fourier-transform infrared spectroscopy (FTIR) were investigated to determine estrogen in the water environment, including heating for atomization, solvent removal, sample deposition, drive control, spectrum collection, chip swap, cleaning and drying. Results showed that when the atomization temperature was increased to 388 K, the interference of mobile phase components (methanol, H2O, acetonitrile, and NaH2PO4) were completely removed in the IR measurement of estrogen, with 0.999 of similarity between IR spectra obtained after separation and corresponding to the standard IR spectra. In experiments with varying HPLC injection volumes, high similarity for IR spectra was obtained at 20 ul injection volume at 0.01 mg/L BPA while a useful IR spectrum for 10 ng/L BPA was obtained at 80 ul injection volume. In addition, estrogen concentrations in the natural water samples were calculated semi-quantitatively from the peak intensities of IR spectrum in the mid-infrared region. PMID:27577974

  18. Separation and determination of estrogen in the water environment by high performance liquid chromatography-fourier transform infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Zheng, Bei; Li, Wentao; Li, Hongyan; Liu, Lin; Lei, Pei; Ge, Xiaopeng; Yu, Zhiyong; Zhou, Yiqi

    2016-08-01

    The components for connecting high-performance liquid chromatography (HPLC) with Fourier-transform infrared spectroscopy (FTIR) were investigated to determine estrogen in the water environment, including heating for atomization, solvent removal, sample deposition, drive control, spectrum collection, chip swap, cleaning and drying. Results showed that when the atomization temperature was increased to 388 K, the interference of mobile phase components (methanol, H2O, acetonitrile, and NaH2PO4) were completely removed in the IR measurement of estrogen, with 0.999 of similarity between IR spectra obtained after separation and corresponding to the standard IR spectra. In experiments with varying HPLC injection volumes, high similarity for IR spectra was obtained at 20 ul injection volume at 0.01 mg/L BPA while a useful IR spectrum for 10 ng/L BPA was obtained at 80 ul injection volume. In addition, estrogen concentrations in the natural water samples were calculated semi-quantitatively from the peak intensities of IR spectrum in the mid-infrared region.

  19. Planar micromixer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fiechtner, Gregory J; Singh, Anup K; Wiedenman, Boyd J

    2008-03-18

    The present embodiment describes a laminar-mixing embodiment that utilizes simple, three-dimensional injection. Also described is the use of the embodiment in combination with wide and shallow sections of channel to affect rapid mixing in microanalytical systems. The shallow channel sections are constructed using all planar micromachining techniques, including those based on isotropic etching. The planar construction enables design using minimum dispersion concepts that, in turn, enable simultaneous mixing and injection into subsequent chromatography channels.

  20. Measuring Compartment Size and Gas Solubility in Marine Mammals

    DTIC Science & Technology

    2014-09-30

    analyzed by gas chromatography . Injection of the sample into the gas chromatograph is done using a sample loop to minimize volume injection error. We...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Measuring Compartment Size and Gas Solubility in Marine...study is to develop methods to estimate marine mammal tissue compartment sizes, and tissue gas solubility. We aim to improve the data available for

  1. Chemometric Deconvolution of Continuous Electrokinetic Injection Micellar Electrokinetic Chromatography Data for the Quantitation of Trinitrotoluene in Mixtures of Other Nitroaromatic Compounds

    DTIC Science & Technology

    2014-02-24

    Suite 600 Washington, DC 20036 NRL/MR/ 6110 --14-9521 Approved for public release; distribution is unlimited. 1Science & Engineering Apprenticeship...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/ 6110 --14-9521 Chemometric Deconvolution of Continuous Electrokinetic Injection Micellar... Engineering Apprenticeship Program American Society for Engineering Education Washington, DC Kevin Johnson Navy Technology Center for Safety and

  2. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Laborda, Francisco; Medrano, Jesús; Castillo, Juan R.

    2004-06-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ.

  3. Evaluation of a direct injection nebulizer interface for flow injection analysis and high performance liquid chromatography with inductively coupled plasma-atomic emission spectroscopic detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaFreniere, K.E.

    A direct injection nebulizer (DIN) was designed, developed and evaluated to determine its potential utilization as an effective interface for flow injection analysis (FIA) and high performance liquid chromatography (HPLC) coupled with inductively coupled plasma-atomic emission spectroscopic detection. The analytical figures of merit for the DIN when used as an interface for FIA-ICP-AES were found to be comparable to or better than those obtained with conventional pneumatic nebulization in terms of limits of detection (LODs), reproducibility, linearity, and interelement effects. In the HPLC mode, the LODDs were found to be comparable to those obtained by continuous-flow sample introduction into themore » ICP, or inferior by up to only a factor of four. Stable plasma operation was maintained for the DIN sample introduction of a variety of pure organic solvents, including acetonitrile, methanol, methyl-isobutylketone, and pyridine. The HPLC-DIN-ICP-AES facility was specifically applied for the speciation of inorganic and organo-metallic species contained in synthetic mixtures, vanilla extracts and a variety of energy-related materials, such as shale oil process water, coal extracts, shale oil, crude oil, and an SRC II. Suggestions for future research are also considered.« less

  4. Differentiating Organic and Conventional Sage by Chromatographic and Mass Spectrometry Flow-Injection Fingerprints Combined with Principal Component Analysis

    PubMed Central

    Gao, Boyan; Lu, Yingjian; Sheng, Yi; Chen, Pei; Yu, Liangli (Lucy)

    2013-01-01

    High performance liquid chromatography (HPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The individual components in the sage samples were also characterized with an ultra-performance liquid chromatography with a quadrupole-time of flight mass spectrometer (UPLC Q-TOF MS). The results suggested that both HPLC and FIMS fingerprints combined with PCA could differentiate organic and conventional sage samples effectively. FIMS may serve as a quick test capable of distinguishing organic and conventional sages in 1 min, and could potentially be developed for high-throughput applications; whereas HPLC fingerprints could provide more chemical composition information with a longer analytical time. PMID:23464755

  5. Modified electrokinetic sample injection method in chromatography and electrophoresis analysis

    DOEpatents

    Davidson, J. Courtney; Balch, Joseph W.

    2001-01-01

    A sample injection method for horizontal configured multiple chromatography or electrophoresis units, each containing a number of separation/analysis channels, that enables efficient introduction of analyte samples. This method for loading when taken in conjunction with horizontal microchannels allows much reduced sample volumes and a means of sample stacking to greatly reduce the concentration of the sample. This reduction in the amount of sample can lead to great cost savings in sample preparation, particularly in massively parallel applications such as DNA sequencing. The essence of this method is in preparation of the input of the separation channel, the physical sample introduction, and subsequent removal of excess material. By this method, sample volumes of 100 nanoliter to 2 microliters have been used successfully, compared to the typical 5 microliters of sample required by the prior separation/analysis method.

  6. A simple dual online ultra-high pressure liquid chromatography system (sDO-UHPLC) for high throughput proteome analysis.

    PubMed

    Lee, Hangyeore; Mun, Dong-Gi; Bae, Jingi; Kim, Hokeun; Oh, Se Yeon; Park, Young Soo; Lee, Jae-Hyuk; Lee, Sang-Won

    2015-08-21

    We report a new and simple design of a fully automated dual-online ultra-high pressure liquid chromatography system. The system employs only two nano-volume switching valves (a two-position four port valve and a two-position ten port valve) that direct solvent flows from two binary nano-pumps for parallel operation of two analytical columns and two solid phase extraction (SPE) columns. Despite the simple design, the sDO-UHPLC offers many advantageous features that include high duty cycle, back flushing sample injection for fast and narrow zone sample injection, online desalting, high separation resolution and high intra/inter-column reproducibility. This system was applied to analyze proteome samples not only in high throughput deep proteome profiling experiments but also in high throughput MRM experiments.

  7. Comprehensive analysis of chemical constituents in Xingxiong injection by high performance liquid chromatography coupled with mass spectrometry.

    PubMed

    Guo, Long; Dou, Li-Li; Duan, Li; Liu, Ke; Bi, Zhi-Ming; Li, Ping; Liu, E-Hu

    2015-09-01

    Xingxiong injection (XXI) is a widely used Chinese herbal formula prepared by the folium ginkgo extract and ligustrazine for the treatment of cardiovascular and cerebrovascular diseases. Compared with the pharmacological studies, chemical analysis and quality control studies on this formula are relatively limited. In the present study, a high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (HPLC-QTOF MS) method was applied to comprehensive analysis of constituents in XXI. According to the fragmentation rules and previous reports, thirty ginkgo flavonoids, four ginkgo terpene lactones, and one alkaloid were identified. A high performance liquid chromatography coupled with triple quadrupole mass spectrometry (HPLC-QQQ MS) method was then applied to quantify ten major constituents in XXI. The method validation results indicated that the developed method had desirable specificity, linearity, precision and accuracy. The total contents of ginkgo flavonoids were about 22.05-25.51 μg·mL(-1) and the ginkgo terpene lactones amounts were about 4.41-8.70 μg·mL(-1) in six batches of XXI samples, respectively. Furthermore, cosine ratio algorithm and distance measurements were employed to evaluate the similarity of XXI samples, and the results demonstrated a high-quality consistency. This work could provide comprehensive information on the quality control of Xingxiong injection, which be helpful in the establishment of a rational quality control standard. Copyright © 2015 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  8. Simple and rapid analysis of endocrine disruptors in liquid medicines and intravenous injection solutions by automated in-tube solid-phase microextraction/high performance liquid chromatography.

    PubMed

    Mitani, Kurie; Narimatsu, Shizuo; Izushi, Fumio; Kataoka, Hiroyuki

    2003-07-14

    A simple and rapid method was developed for analyzing contamination of endocrine disruptors in liquid medicines and intravenous injection solutions. Endocrine disrupting compounds such as bisphenol A (BPA), alkylphenols and phthalates were quantitated by on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography (in-tube SPME/HPLC) with UV detection. The liquid medicines and intravenous injection solutions could be used directly without any pretreatment, and the BPA, alkylphenols and phthalates in these solutions were automatically analyzed. The limits of quantification for these compounds were 1-10 ng/ml. Recoveries of these compounds spiked to the intravenous injection solutions was over 80%, except for some phthalates. Di-n-butyl phthalate (DBP) was detected at a concentration of 7-60 ng/ml in most intravenous injection solutions in plastic containers, but it was not detected in solutions in glass bottles. Diethyl phthalate, di-n-propyl phthalate, DBP and di-2-ethylhexyl phthalate (DEHP) were also detected in syrup, lotion and eye drops in plastic containers. On the other hand, BPA and alkylphenols were not detected at all in these solutions. DEHP contamination from an administration set increased when total vitamin formulation was added to the infusion solution. DEHP was easily leached from polyvinyl chloride tubing by polysorbate 80. The in-tube SPME/HPLC method is simple, rapid and automatic, and it provides a useful tool for the screening and determination of endocrine disruptor contamination in liquid medicines and intravenous injection solutions.

  9. Demonstration and Evaluation of Solid Phase Microextraction for the Assessment of Bioavailability and Contaminant Mobility. ESTCP Cost and Performance Report

    DTIC Science & Technology

    2012-08-01

    subsequent chemical analysis (into acetonitrile for high-performance liquid chromatography [ HPLC ] analysis or hexane for gas chromatography [GC... analysis ) is rapid and complete. In this work, PAHs were analyzed by Waters 2795 HPLC with fluorescent detection (USEPA Method 8310) and PCBs were...detection limits by direct water injection versus SPME with PDMS and coefficient of variation and correlation coefficient for SPME. Analysis by HPLC

  10. Determination of a Jet Fuel Metal Deactivator by High Performance Liquid Chromatography

    DTIC Science & Technology

    1983-06-01

    bonded phase chromatography (Reference 2). 73 AFWAL-TR-82-2128 Bonded phase packings offer distinct advantages over other packings: a. Irreversible...were then oven dried and placed in a dessicator for cooling and storage until use. The bottles were subsequently silanized with "Glas-TREET" ( Alltech ... advantages of a loop injector are: (1) The volume injected is far more repeatable since a fixed volume loop has a constant volume and is flushed with a

  11. A high pressure liquid chromatography method for separation of prolactin forms.

    PubMed

    Bell, Damon A; Hoad, Kirsten; Leong, Lillian; Bakar, Juwaini Abu; Sheehan, Paul; Vasikaran, Samuel D

    2012-05-01

    Prolactin has multiple forms and macroprolactin, which is thought not to be bioavailable, can cause a raised serum prolactin concentration. Gel filtration chromatography (GFC) is currently the gold standard method for separating macroprolactin, but is labour-intensive. Polyethylene glycol (PEG) precipitation is suitable for routine use but may not always be accurate. We developed a high pressure liquid chromatography (HPLC) assay for macroprolactin measurement. Chromatography was carried out using an Agilent Zorbax GF-250 (9.4 × 250 mm, 4 μm) size exclusion column and 50 mmol/L Tris buffer with 0.15 mmol/L NaCl at pH 7.2 as mobile phase, with a flow rate of 1 mL/min. Serum or plasma was diluted 1:1 with mobile phase and filtered and 100 μL injected. Fractions of 155 μL were collected for prolactin measurement and elution profile plotted. The area under the curve of each prolactin peak was calculated to quantify each prolactin form, and compared with GFC. Clear separation of monomeric-, big- and macroprolactin forms was achieved. Quantification was comparable to GFC and precision was acceptable. Total time from injection to collection of the final fraction was 16 min. We have developed an HPLC method for quantification of macroprolactin, which is rapid and easy to perform and therefore can be used for routine measurement.

  12. Simulation of elution profiles in liquid chromatography - II: Investigation of injection volume overload under gradient elution conditions applied to second dimension separations in two-dimensional liquid chromatography.

    PubMed

    Stoll, Dwight R; Sajulga, Ray W; Voigt, Bryan N; Larson, Eli J; Jeong, Lena N; Rutan, Sarah C

    2017-11-10

    An important research direction in the continued development of two-dimensional liquid chromatography (2D-LC) is to improve the detection sensitivity of the method. This is especially important in applications where injection of large volumes of effluent from the first dimension ( 1 D) column into the second dimension ( 2 D) column leads to severe 2 D peak broadening and peak shape distortion. For example, this is common when coupling two reversed-phase columns and the organic solvent content of the 1 D mobile phase overwhelms the 2 D column with each injection of 1 D effluent, leading to low resolution in the second dimension. In a previous study we validated a simulation approach based on the Craig distribution model and adapted from the work of Czok and Guiochon [1] that enabled accurate simulation of simple isocratic and gradient separations with very small injection volumes, and isocratic separations with mismatched injection and mobile phase solvents [2]. In the present study we have extended this simulation approach to simulate separations relevant to 2D-LC. Specifically, we have focused on simulating 2 D separations where gradient elution conditions are used, there is mismatch between the sample solvent and the starting point in the gradient elution program, injection volumes approach or even exceed the dead volume of the 2 D column, and the extent of sample loop filling is varied. To validate this simulation we have compared results from simulations and experiments for 101 different conditions, including variation in injection volume (0.4-80μL), loop filling level (25-100%), and degree of mismatch between sample organic solvent and the starting point in the gradient elution program (-20 to +20% ACN). We find that that the simulation is accurate enough (median errors in retention time and peak width of -1.0 and -4.9%, without corrections for extra-column dispersion) to be useful in guiding optimization of 2D-LC separations. However, this requires that real injection profiles obtained from 2D-LC interface valves are used to simulate the introduction of samples into the 2 D column. These profiles are highly asymmetric - simulation using simple rectangular pulses leads to peak widths that are far too narrow under many conditions. We believe the simulation approach developed here will be useful for addressing practical questions in the development of 2D-LC methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. The duration of hyaluronidase and optimal timing of hyaluronic acid (HA) filler reinjection after hyaluronidase injection.

    PubMed

    Kim, H J; Kwon, S B; Whang, K U; Lee, J S; Park, Y L; Lee, S Y

    2018-02-01

    Hyaluronidase injection is a commonly performed treatment for overcorrection or misplacement of hyaluronic acid (HA) filler. Many patients often wants the HA filler reinjection after the use of hyaluronidase, though the optimal timing of reinjection of HA filler still remains unknown. To provide the optimal time interval between hyaluronidase injections and HA filler reinjections. 6 Sprague-Dawley rats were injected with single monophasic HA filler. 1 week after injection, the injected sites were treated with hyaluronidase. Then, HA fillers were reinjected sequentially with differing time intervals from 30 minutes to 14 days. 1 hour after the reinjection of the last HA filler, all injection sites were excised for histologic evaluation. 3 hours after reinjection of HA filler, the appearance of filler material became evident again, retaining its shape and volume. 6 hours after reinjection, the filler materials restored almost its original volume and there were no significant differences from the positive control. Our data suggest that the hyaluronidase loses its effect in dermis and subcutaneous tissue within 3-6 hours after the injection and successful engraftment of reinjected HA filler can be accomplished 6 hours after the injection.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Xiangmei; Mort, Andrew

    A comore » mmercial apple pectin was sequentially digested with the cloned enzymes endopolygalacturonase, galactanase, arabinofuranosidase, xylogalacturonase, and rhamnogalacturonan hydrolase. The rhamnogalacturonan hydrolase-generated oligosaccharides were separated by ultrafiltration, anion exchange, and size-exclusion chromatography. Fractions from the ion exchange chromatography were pooled, lyophilized, and screened by MALDI-TOF MS. An oligosaccharide (RGP14P3) was identified and its structure, α -D-Gal p A- ( 1 → 2 ) - α -L-Rha p - ( 1 → 4 ) - α -D-Gal p A- ( 1 → 2 ) - α -L-Rha p - ( 1 → 4 ) - α -D-Gal p A, determined by 1D and 2D NMR spectrometry. This oligosaccharide probably represents a direct connection between homogalacturonan and rhamnogalacturonan in pectin. Alternatively, it could indicate that the nonreducing end of rhamnogalacturonan starts with a galacturonic acid residue.« less

  15. New evidences on efficacy of boronic acid-based derivatization method to identify sugars in plant material by gas chromatography-mass spectrometry.

    PubMed

    Faraco, Marianna; Fico, Daniela; Pennetta, Antonio; De Benedetto, Giuseppe E

    2016-10-01

    This work presents an analytical procedure based on gas chromatography-mass spectrometry which allows the determination of aldoses (glucose, mannose, galactose, arabinose, xylose, fucose, rhamnose) and chetoses (fructose) in plant material. One peak for each target carbohydrate was obtained by using an efficient derivatization employing methylboronic acid and acetic anhydride sequentially, whereas the baseline separation of the analytes was accomplished using an ionic liquid capillary column. First, the proposed method was optimized and validated. Successively, it was applied to identify the carbohydrates present in plant material. Finally, the procedure was successfully applied to samples from a XVII century painting, thus highlighting the occurrence of starch glue and fruit tree gum as polysaccharide materials. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Fast batch injection analysis system for on-site determination of ethanol in gasohol and fuel ethanol.

    PubMed

    Pereira, Polyana F; Marra, Mariana C; Munoz, Rodrigo A A; Richter, Eduardo M

    2012-02-15

    A simple, accurate and fast (180 injections h(-1)) batch injection analysis (BIA) system with multiple-pulse amperometric detection has been developed for selective determination of ethanol in gasohol and fuel ethanol. A sample aliquot (100 μL) was directly injected onto a gold electrode immersed in 0.5 mol L(-1) NaOH solution (unique reagent). The proposed BIA method requires minimal sample manipulation and can be easily used for on-site analysis. The results obtained with the BIA method were compared to those obtained by gas-chromatography and similar results were obtained (at 95% of confidence level). Published by Elsevier B.V.

  17. Development of a split-flow system for high precision variable sample introduction in supercritical fluid chromatography.

    PubMed

    Sakai, Miho; Hayakawa, Yoshihiro; Funada, Yasuhiro; Ando, Takashi; Fukusaki, Eiichiro; Bamba, Takeshi

    2017-09-15

    In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔP columnsideinsplitless and ΔP columnsideinsplit , respectively, where ΔP columnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop. Copyright © 2017. Published by Elsevier B.V.

  18. Bioactive Lipidic Extracts from Octopus (Paraoctopus limaculatus): Antimutagenicity and Antiproliferative Studies

    PubMed Central

    Moreno-Félix, Carolina; Wilson-Sánchez, Griselda; Cruz-Ramírez, Susana-Gabriela; Velázquez-Contreras, Carlos; Plascencia-Jatomea, Maribel; Acosta, Ana; Machi-Lara, Lorena; Aldana-Madrid, María-Lourdes; Ezquerra-Brauer, Josafat-Marina; Rocha-Alonzo, Fernando; Burgos-Hernández, Armando

    2013-01-01

    Fractions from an organic extract from fresh octopus (Paraoctopus limaculatus) were studied for biological activities such as antimutagenic and antiproliferative properties using Salmonella tester strains TA98 and TA100 with metabolic activation (S9) and a cancer cell line (B-cell lymphoma), respectively. A chloroform extract obtained from octopus tentacles was sequentially fractionated using thin layer chromatography (TLC), and each fraction was tested for antimutagenic and antiproliferative activities. Organic extract reduced the number of revertants caused by aflatoxin B1 showing a dose-response type of relationship. Sequential TLC fractionation of the active extracts produced several antimutagenic and/or antiproliferative fractions. Based on the results obtained, the isolated fractions obtained from octopus contain compounds with chemoprotective properties that reduce the mutagenicity of AFB1 and proliferation of cancer cell lines. PMID:23401709

  19. Contamination of injectable solutions with 2-mercaptobenzothiazole leached from rubber closures.

    PubMed

    Reepmeyer, J C; Juhl, Y H

    1983-11-01

    An impurity, discovered in a sample of digoxin injectable solution commercially packaged in a syringe for single-dose delivery, was found to originate from the rubber closure of the syringe and was identified as 2-mercaptobenzothiazole, a common accelerator for rubber vulcanization. Several similarly packaged injectable solutions of a variety of drugs from various manufacturers were examined and over half contained 2-mercaptobenzothiazole. The compound was identified by UV spectrophotometry (including a pH-dependent shift in its absorbance maximum), by mass spectrometry, and by comparison with standard 2-mercaptobenzothiazole using silica gel and reverse-phase high-performance liquid chromatography (HPLC). The presence of this impurity in injectable solutions may have implications with regard to toxicity and may interfere with the assay of digoxin injectable solution by HPLC.

  20. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C.J. Miller; G. Elias; N.C. Schmitt

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that weremore » used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.« less

  1. 9 CFR 113.43 - Detection of chlamydial agents.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... in a filed Outline of Production. (a) The yolk sac of 6-day-old chicken embryos shall be injected. Three groups of 10 embryos shall be used sequentially. (1) The inoculum for each embryo in the first... embryos shall be harvested, pooled, homogenized as a 20 percent suspension in phosphate buffered saline...

  2. 9 CFR 113.43 - Detection of chlamydial agents.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... in a filed Outline of Production. (a) The yolk sac of 6-day-old chicken embryos shall be injected. Three groups of 10 embryos shall be used sequentially. (1) The inoculum for each embryo in the first... embryos shall be harvested, pooled, homogenized as a 20 percent suspension in phosphate buffered saline...

  3. 9 CFR 113.43 - Detection of chlamydial agents.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... in a filed Outline of Production. (a) The yolk sac of 6-day-old chicken embryos shall be injected. Three groups of 10 embryos shall be used sequentially. (1) The inoculum for each embryo in the first... embryos shall be harvested, pooled, homogenized as a 20 percent suspension in phosphate buffered saline...

  4. 9 CFR 113.43 - Detection of chlamydial agents.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... in a filed Outline of Production. (a) The yolk sac of 6-day-old chicken embryos shall be injected. Three groups of 10 embryos shall be used sequentially. (1) The inoculum for each embryo in the first... embryos shall be harvested, pooled, homogenized as a 20 percent suspension in phosphate buffered saline...

  5. Generic HPLC platform for automated enzyme reaction monitoring: Advancing the assay toolbox for transaminases and other PLP-dependent enzymes.

    PubMed

    Börner, Tim; Grey, Carl; Adlercreutz, Patrick

    2016-08-01

    Methods for rapid and direct quantification of enzyme kinetics independent of the substrate stand in high demand for both fundamental research and bioprocess development. This study addresses the need for a generic method by developing an automated, standardizable HPLC platform monitoring reaction progress in near real-time. The method was applied to amine transaminase (ATA) catalyzed reactions intensifying process development for chiral amine synthesis. Autosampler-assisted pipetting facilitates integrated mixing and sampling under controlled temperature. Crude enzyme formulations in high and low substrate concentrations can be employed. Sequential, small (1 µL) sample injections and immediate detection after separation permits fast reaction monitoring with excellent sensitivity, accuracy and reproducibility. Due to its modular design, different chromatographic techniques, e.g. reverse phase and size exclusion chromatography (SEC) can be employed. A novel assay for pyridoxal 5'-phosphate-dependent enzymes is presented using SEC for direct monitoring of enzyme-bound and free reaction intermediates. Time-resolved changes of the different cofactor states, e.g. pyridoxal 5'-phosphate, pyridoxamine 5'-phosphate and the internal aldimine were traced in both half reactions. The combination of the automated HPLC platform with SEC offers a method for substrate-independent screening, which renders a missing piece in the assay and screening toolbox for ATAs and other PLP-dependent enzymes. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. A Simple Automated Method for the Determination of Nitrate and Nitrite in Infant Formula and Milk Powder Using Sequential Injection Analysis

    PubMed Central

    Pistón, Mariela; Mollo, Alicia; Knochen, Moisés

    2011-01-01

    A fast and efficient automated method using a sequential injection analysis (SIA) system, based on the Griess, reaction was developed for the determination of nitrate and nitrite in infant formulas and milk powder. The system enables to mix a measured amount of sample (previously constituted in the liquid form and deproteinized) with the chromogenic reagent to produce a colored substance whose absorbance was recorded. For nitrate determination, an on-line prereduction step was added by passing the sample through a Cd minicolumn. The system was controlled from a PC by means of a user-friendly program. Figures of merit include linearity (r2 > 0.999 for both analytes), limits of detection (0.32 mg kg−1 NO3-N, and 0.05 mg kg−1 NO2-N), and precision (sr%) 0.8–3.0. Results were statistically in good agreement with those obtained with the reference ISO-IDF method. The sampling frequency was 30 hour−1 (nitrate) and 80 hour−1 (nitrite) when performed separately. PMID:21960750

  7. LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes.

    PubMed

    Economou, Anastasios; Voulgaropoulos, Anastasios

    2003-01-01

    The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming of the experimental sequence was performed in LabVIEW 5.1. The sequence of operations included formation of the mercury film, electrolytic or adsorptive accumulation of the analyte on the electrode surface, recording of the voltammetric current-potential response, and cleaning of the electrode. The stripping step was carried out by applying a square-wave (SW) potential-time excitation signal to the working electrode. The instrument allowed unattended operation since multiple-step sequences could be readily implemented through the purpose-built software. The utility of the analyser was tested for the determination of copper(II), cadmium(II), lead(II) and zinc(II) by SWASV and of nickel(II), cobalt(II) and uranium(VI) by SWAdSV.

  8. LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes

    PubMed Central

    Economou, Anastasios; Voulgaropoulos, Anastasios

    2003-01-01

    The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming of the experimental sequence was performed in LabVIEW 5.1. The sequence of operations included formation of the mercury film, electrolytic or adsorptive accumulation of the analyte on the electrode surface, recording of the voltammetric current-potential response, and cleaning of the electrode. The stripping step was carried out by applying a square-wave (SW) potential-time excitation signal to the working electrode. The instrument allowed unattended operation since multiple-step sequences could be readily implemented through the purpose-built software. The utility of the analyser was tested for the determination of copper(II), cadmium(II), lead(II) and zinc(II) by SWASV and of nickel(II), cobalt(II) and uranium(VI) by SWAdSV. PMID:18924623

  9. Sequential injection system with multi-parameter analysis capability for water quality measurement.

    PubMed

    Kaewwonglom, Natcha; Jakmunee, Jaroon

    2015-11-01

    A simple sequential injection (SI) system with capability to determine multi-parameter has been developed for the determination of iron, manganese, phosphate and ammonium. A simple and compact colorimeter was fabricated in the laboratory to be employed as a detector. The system was optimized for suitable conditions for determining each parameter by changing software program and without reconfiguration of the hardware. Under the optimum conditions, the methods showed linear ranges of 0.2-10 mg L(-1) for iron and manganese determinations, and 0.3-5.0 mg L(-1) for phosphate and ammonium determinations, with correlation coefficients of 0.9998, 0.9973, 0.9987 and 0.9983, respectively. The system provided detection limits of 0.01, 0.14, 0.004 and 0.02 mg L(-1) for iron, manganese, phosphate and ammonium, respectively. The proposed system has good precision, low chemical consumption and high throughput. It was applied for monitoring water quality of Ping river in Chiang Mai, Thailand. Recoveries of the analysis were obtained in the range of 82-119%. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Deferiprone, a non-toxic reagent for determination of iron in samples via sequential injection analysis

    NASA Astrophysics Data System (ADS)

    Pragourpun, Kraivinee; Sakee, Uthai; Fernandez, Carlos; Kruanetr, Senee

    2015-05-01

    We present for the first time the use of deferiprone as a non-toxic complexing agent for the determination of iron by sequential injection analysis in pharmaceuticals and food samples. The method was based on the reaction of Fe(III) and deferiprone in phosphate buffer at pH 7.5 to give a Fe(III)-deferiprone complex, which showed a maximum absorption at 460 nm. Under the optimum conditions, the linearity range for iron determination was found over the range of 0.05-3.0 μg mL-1 with a correlation coefficient (r2) of 0.9993. The limit of detection and limit of quantitation were 0.032 μg mL-1 and 0.055 μg mL-1, respectively. The relative standard deviation (%RSD) of the method was less than 5.0% (n = 11), and the percentage recovery was found in the range of 96.0-104.0%. The proposed method was satisfactorily applied for the determination of Fe(III) in pharmaceuticals, water and food samples with a sampling rate of 60 h-1.

  11. Sequential PLD in oxygen/argon gas mixture of Al-doped ZnO thin films with improved electrical and optical properties

    NASA Astrophysics Data System (ADS)

    Coman, Tudor; Timpu, Daniel; Nica, Valentin; Vitelaru, Catalin; Rambu, Alicia Petronela; Stoian, George; Olaru, Mihaela; Ursu, Cristian

    2017-10-01

    Highly conductive transparent Al-doped ZnO (AZO) thin films were obtained at room temperature through sequential PLD (SPLD) from Zn and Al metallic targets in an oxygen/argon gas mixture. We have investigated the structural, electrical and optical properties as a function of the oxygen/argon pressure ratio in the chamber. The measured Hall carrier concentration was found to increase with argon injection from 1.3 × 1020 to 6.7 × 1020 cm-3, while the laser shots ratio for Al/Zn targets ablation was kept constant. This increase was attributed to an enhancement of the substitution doping into the ZnO lattice. The argon injection also leads to an increase of the Hall mobility up to 20 cm2 V-1 s-1, attributed to a reduction of interstitial-type defects. Thus, the approach of using an oxygen/argon gas mixture during SPLD from metallic targets allows obtaining at room temperature AZO samples with high optical transmittance (about 90%) and low electrical resistivity (down to 5.1 × 10-4 Ω cm).

  12. Structural characterization of alkali-soluble polysaccharides from Panax ginseng C. A. Meyer

    PubMed Central

    Ji, Li; Jie, Zhenjing; Ying, Xin; Yue, Qi; Zhou, Yifa

    2018-01-01

    Panax ginseng C. A. Meyer (ginseng) has been widely used as a herb and functional food in the world. Polysaccharides are the main active components of ginseng. In this paper, the polysaccharides were sequentially extracted by 50 mM Na2CO3, 1 M KOH and 4 M KOH from ginseng roots treated sequentially with hot water, α-amylase and ethylenediaminetetraacetic acid extraction. Na2CO3-soluble ginseng polysaccharide (NGP) was fractionated into one neutral and three acidic fractions by anion exchange and gel permeation chromatography. Fourier transform infrared, NMR and methylation analysis indicated acidic fractions in NGP were highly branched rhamnogalacturonan-I domains, with  → 4)-α-GalpA-(1 → 2)-α-Rhap-(1 → disaccharide repeating units as backbone and β-1,4-galactan, α-1,5/1,3,5-arabinan and type II arabinogalactan as side chains. 1-KGP (1 M KOH-soluble ginseng polysaccharide) and 4-KGP (4 M KOH-soluble ginseng polysaccharide) were mainly composed of hemicellulose besides starch-like polysaccharides and minor pectin. Antibody detection, enzymic hydrolysis, high performance anion exchange chromatography and methylation analysis demonstrated xylan was the major component in 1-KGP, while xyloglucan was predominant in 4-KGP. Comparing the polysaccharides obtained by different solvent extractions, we have a comprehensive understanding about total ginseng polysaccharides. PMID:29657770

  13. Monolithic Integration of Two-Dimensional Liquid Chromatography-Capillary Electrophoresis and Electrospray Ionization on a Microfluidic Device

    PubMed Central

    Chambers, Andrew G.; Mellors, J. Scott; Henley, W. Hampton; Ramsey, J. Michael

    2011-01-01

    A microfluidic device capable of two-dimensional reversed-phase liquid chromatography-capillary electrophoresis with integrated electrospray ionization (LC-CE-ESI) for mass spectrometry (MS)-based proteomic applications is described. Traditional instrumentation was used for the LC sample injection and delivery of the LC mobile phase. The glass microfabricated device incorporated a sample-trapping region and an LC channel packed with reversed-phase particles. Rapid electrokinetic injections of the LC effluent into the CE dimension were performed at a cross channel intersection. The CE separation channel terminated at a corner of the square device, which functioned as an integrated electrospray tip. In addition to LC-CE-ESI, this device was used for LC-ESI without any instrumental modifications. To evaluate the system, LC-MS and LC-CE-MS analysis of protein digests were performed and compared. PMID:21214194

  14. Determination of highly protein bound drugs in plasma using high-performance liquid chromatography and column switching, exemplified by the retinoids.

    PubMed

    Wyss, R; Bucheli, F

    1988-12-02

    During method development for the determination of either isotretinoin, tretinoin and their 4-oxo-metabolites, or etretinate, acitretin and 13-cis-acitretin in plasma using high-performance liquid chromatography and column switching, recovery problems arose, when undiluted plasma samples were injected directly onto the precolumn. These recovery problems may be due to the strong binding of the retinoids to different plasma proteins. Measures to overcome this strong protein binding, such as variation of the injection solution composition and the purge mobile phase, were systematically investigated. Best recoveries were obtained by diluting of plasma with 9 mM sodium hydroxide-acetonitrile (8:2, v/v) and protein precipitation with ethanol for the isotretinoin and etretinate series, respectively, in combination with the use of a purge mobile phase containing ammonium acetate and 10-20% acetonitrile. Less effective was the use of a longer precolumn or heating of the precolumn.

  15. Simultaneous enantioselective quantification of fluoxetine and norfluoxetine in human milk by direct sample injection using 2-dimensional liquid chromatography-tandem mass spectrometry.

    PubMed

    Alvim, Joel; Lopes, Bianca Rebelo; Cass, Quezia Bezerra

    2016-06-17

    A two-dimensional liquid chromatography system coupled to triple quadrupole tandem mass spectrometer (2D LC-MS/MS) was employed for the simultaneously quantification of fluoxetine (FLX) and norfluoxetine (NFLX) enantiomers in human milk by direct injection of samples. A restricted access media of bovine serum albumin octadecyl column (RAM-BSAC18) was used in the first dimension for the milk proteins depletion, while an antibiotic-based chiral column was used in the second dimension. The results herein described show good selectivity, extraction efficiency, accuracy, and precision with limits of quantification in the order of 7.5ngmL(-1)for the FLX enantiomers and 10.0ngmL(-1) for NFLX enantiomers. Furthermore, it represents a practical tool in terms of sustainability for the sample preparation of such a difficult matrix. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Analysis of polycyclic aromatic hydrocarbons in water and beverages using membrane-assisted solvent extraction in combination with large volume injection-gas chromatography-mass spectrometric detection.

    PubMed

    Rodil, Rosario; Schellin, Manuela; Popp, Peter

    2007-09-07

    Membrane-assisted solvent extraction (MASE) in combination with large volume injection-gas chromatography-mass spectrometry (LVI-GC-MS) was applied for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. The MASE conditions were optimized for achieving high enrichment of the analytes from aqueous samples, in terms of extraction conditions (shaking speed, extraction temperature and time), extraction solvent and composition (ionic strength, sample pH and presence of organic solvent). Parameters like linearity and reproducibility of the procedure were determined. The extraction efficiency was above 65% for all the analytes and the relative standard deviation (RSD) for five consecutive extractions ranged from 6 to 18%. At optimized conditions detection limits at the ng/L level were achieved. The effectiveness of the method was tested by analyzing real samples, such as river water, apple juice, red wine and milk.

  17. Comparison of intraosseous and infiltration injections for venous lidocaine blood concentrations and heart rate changes after injection of 2% lidocaine with 1:100,000 epinephrine.

    PubMed

    Wood, Mark; Reader, Al; Nusstein, John; Beck, Mike; Padgett, David; Weaver, Joel

    2005-06-01

    The purpose of this prospective, randomized study was to compare the venous blood levels of lidocaine and heart rate changes after intraosseous and infiltration injections of 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. Using a crossover design, 20 subjects randomly received an intraosseous and infiltration injection at two separate appointments. The heart rate was measured using a pulse oximeter. Venous blood samples were collected before the injections and at 2, 5, 10, 15, 20, 25, 30, 45, and 60 min after the injections. The blinded plasma samples were analyzed for lidocaine concentrations using high-performance liquid chromatography (HPLC). The intraosseous injection resulted in a statistically significant increase in heart rate, when compared to the infiltration injection, during solution deposition and for 2 min after the injection. The plasma levels of lidocaine were not statistically different for maxillary anterior intraosseous and infiltration injections when using 1.8 ml of 2% lidocaine with 1:100,000 epinephrine.

  18. On-line sequential injection-capillary electrophoresis for near-real-time monitoring of extracellular lactate in cell culture flasks.

    PubMed

    Alhusban, Ala A; Gaudry, Adam J; Breadmore, Michael C; Gueven, Nuri; Guijt, Rosanne M

    2014-01-03

    Cell culture has replaced many in vivo studies because of ethical and regulatory measures as well as the possibility of increased throughput. Analytical assays to determine (bio)chemical changes are often based on end-point measurements rather than on a series of sequential determinations. The purpose of this work is to develop an analytical system for monitoring cell culture based on sequential injection-capillary electrophoresis (SI-CE) with capacitively coupled contactless conductivity detection (C(4)D). The system was applied for monitoring lactate production, an important metabolic indicator, during mammalian cell culture. Using a background electrolyte consisting of 25mM tris(hydroxymethyl)aminomethane, 35mM cyclohexyl-2-aminoethanesulfonic acid with 0.02% poly(ethyleneimine) (PEI) at pH 8.65 and a multilayer polymer coated capillary, lactate could be resolved from other compounds present in media with relative standard deviations 0.07% for intraday electrophoretic mobility and an analysis time of less than 10min. Using the human embryonic kidney cell line HEK293, lactate concentrations in the cell culture medium were measured every 20min over 3 days, requiring only 8.73μL of sample per run. Combining simplicity, portability, automation, high sample throughput, low limits of detection, low sample consumption and the ability to up- and outscale, this new methodology represents a promising technique for near real-time monitoring of chemical changes in diverse cell culture applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate.

    PubMed

    Khongpet, Wanpen; Pencharee, Somkid; Puangpila, Chanida; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai; Jakmunee, Jaroon

    2018-01-15

    A microfluidic hydrodynamic sequential injection (μHSI) spectrophotometric system was designed and fabricated. The system was built by laser engraving a manifold pattern on an acrylic block and sealing with another flat acrylic plate to form a microfluidic channel platform. The platform was incorporated with small solenoid valves to obtain a portable setup for programmable control of the liquid flow into the channel according to the HSI principle. The system was demonstrated for the determination of phosphate using a molybdenum blue method. An ascorbic acid, standard or sample, and acidic molybdate solutions were sequentially aspirated to fill the channel forming a stack zone before flowing to the detector. Under the optimum condition, a linear calibration graph in the range of 0.1-6mg P L -1 was obtained. The detection limit was 0.1mgL -1 . The system is compact (5.0mm thick, 80mm wide × 140mm long), durable, portable, cost-effective, and consumes little amount of chemicals (83μL each of molybdate and ascorbic acid, 133μL of the sample solution and 1.7mL of water carrier/run). It was applied for the determination of phosphate content in extracted soil samples. The percent recoveries of the analysis were obtained in the range of 91.2-107.3. The results obtained agreed well with those of the batch spectrophotometric method. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Sequential injection titration method using second-order signals: determination of acidity in plant oils and biodiesel samples.

    PubMed

    del Río, Vanessa; Larrechi, M Soledad; Callao, M Pilar

    2010-06-15

    A new concept of flow titration is proposed and demonstrated for the determination of total acidity in plant oils and biodiesel. We use sequential injection analysis (SIA) with a diode array spectrophotometric detector linked to chemometric tools such as multivariate curve resolution-alternating least squares (MCR-ALS). This system is based on the evolution of the basic specie of an acid-base indicator, alizarine, when it comes into contact with a sample that contains free fatty acids. The gradual pH change in the reactor coil due to diffusion and reaction phenomenona allows the sequential appearance of both species of the indicator in the detector coil, recording a data matrix for each sample. The SIA-MCR-ALS method helps to reduce the amounts of sample, the reagents and the time consumed. Each determination consumes 0.413ml of sample, 0.250ml of indicator and 3ml of carrier (ethanol) and generates 3.333ml of waste. The frequency of the analysis is high (12 samples h(-1) including all steps, i.e., cleaning, preparing and analysing). The utilized reagents are of common use in the laboratory and it is not necessary to use the reagents of perfect known concentration. The method was applied to determine acidity in plant oil and biodiesel samples. Results obtained by the proposed method compare well with those obtained by the official European Community method that is time consuming and uses large amounts of organic solvents.

  1. Multiplex gas chromatography for use in space craft

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.

    1985-01-01

    Gas chromatography is a powerful technique for the analysis of gaseous mixtures. Some limitations in this technique still exist which can be alleviated with multiplex gas chromatography (MGC). In MGC, rapid multiple sample injections are made into the column without having to wait for one determination to be finished before taking a new sample. The resulting data must then be reduced using computational methods such as cross correlation. In order to efficiently perform multiplexgas chromatography, experiments in the laboratory and on board future space craft, skills, equipment, and computer software were developed. Three new techniques for modulating, i.e., changing, sample concentrations were demonstrated by using desorption, decomposition, and catalytic modulators. In all of them, the need for a separate gas stream as the carrier was avoided by placing the modulator at the head of the column to directly modulate a sample stream. Finally, the analysis of an environmental sample by multiplex chromatography was accomplished by employing silver oxide to catalytically modulate methane in ambient air.

  2. Recent Advance in Liquid Chromatography/Mass Spectrometry Techniques for Environmental Analysis in Japan

    PubMed Central

    Suzuki, Shigeru

    2014-01-01

    The techniques and measurement methods developed in the Environmental Survey and Monitoring of Chemicals by Japan’s Ministry of the Environment, as well as a large amount of knowledge archived in the survey, have led to the advancement of environmental analysis. Recently, technologies such as non-target liquid chromatography/high resolution mass spectrometry and liquid chromatography with micro bore column have further developed the field. Here, the general strategy of a method developed for the liquid chromatography/mass spectrometry (LC/MS) analysis of environmental chemicals with a brief description is presented. Also, a non-target analysis for the identification of environmental pollutants using a provisional fragment database and “MsMsFilter,” an elemental composition elucidation tool, is presented. This analytical method is shown to be highly effective in the identification of a model chemical, the pesticide Bendiocarb. Our improved micro-liquid chromatography injection system showed substantially enhanced sensitivity to perfluoroalkyl substances, with peak areas 32–71 times larger than those observed in conventional LC/MS. PMID:26819891

  3. Injectable 3-D Fabrication of Medical Electronics at the Target Biological Tissues

    NASA Astrophysics Data System (ADS)

    Jin, Chao; Zhang, Jie; Li, Xiaokang; Yang, Xueyao; Li, Jingjing; Liu, Jing

    2013-12-01

    Conventional transplantable biomedical devices generally request sophisticated surgery which however often causes big trauma and serious pain to the patients. Here, we show an alternative way of directly making three-dimensional (3-D) medical electronics inside the biological body through sequential injections of biocompatible packaging material and liquid metal ink. As the most typical electronics, a variety of medical electrodes with different embedded structures were demonstrated to be easily formed at the target tissues. Conceptual in vitro experiments provide strong evidences for the excellent performances of the injectable electrodes. Further in vivo animal experiments disclosed that the formed electrode could serve as both highly efficient ECG (Electrocardiograph) electrode and stimulator electrode. These findings clarified the unique features and practicability of the liquid metal based injectable 3-D fabrication of medical electronics. The present strategy opens the way for directly manufacturing electrophysiological sensors or therapeutic devices in situ via a truly minimally invasive approach.

  4. Attenuation-difference radar tomography: results of a multiple-plane experiment at the U.S. Geological Survey Fractured-Rock Research Site, Mirror Lake, New Hampshire

    USGS Publications Warehouse

    Lane, J.W.; Day-Lewis, F. D.; Harris, J.M.; Haeni, F.P.; Gorelick, S.M.

    2000-01-01

    Attenuation-difference, borehole-radar tomography was used to monitor a series of sodium chloride tracer injection tests conducted within the FSE, wellfield at the U.S. Geological Survey Fractured-Rock Hydrology Research Site in Grafton County, New Hampshire, USA. Borehole-radar tomography surveys were conducted using the sequential-scanning and injection method in three boreholes that form a triangular prism of adjoining tomographic image planes. Results indicate that time-lapse tomography methods provide high-resolution images of tracer distribution in permeable zones.

  5. Determination of low-molecular-weight dicarboxylic acids in atmospheric aerosols by injection-port derivatization and gas chromatography-mass spectrometry.

    PubMed

    Hsu, Ching-Lin; Ding, Wang-Hsien

    2009-12-15

    A rapid and environmental-friendly injection-port derivatization with gas chromatography-mass spectrometry (GC-MS) method was developed to determine selected low-molecular weight (LMW) dicarboxylic acids (from C2 to C10) in atmospheric aerosol samples. The parameters related to the derivatization process (i.e., type of ion-pair reagent, injection-port temperature and concentration of ion-pair reagent) were optimized. Tetrabutylammonium hydroxide (TBA-OH) 20 mM in methanol gave excellent yield for di-butyl ester dicarboxylate derivatives at injection-port temperature at 300 degrees C. Solid-phase extraction (SPE) method instead of rotary evaporation was used to concentrate analytes from filter extracts. The recovery from filter extracts ranged from 78 to 95% with relative standard deviation (RSD) less than 12%. Limits of quantitation (LOQs) ranged from 25 to 250 pg/m(3). The concentrations of di-carboxylated C2-C5 and total C6-C10 in particles of atmospheric aerosols ranged from 91.9 to 240, 11.3 to 56.7, 9.2 to 49.2, 8.7 to 35.3 and n.d. to 37.8 ng/m(3), respectively. Oxalic acid (C2) was the dominant LMW-dicarboxylic acids detected in aerosol samples. The quantitative results were comparable to the results obtained by the off-line derivatization.

  6. Evaluation of Flow-Injection Tandem Mass Spectrometry for Rapid and High-Throughput Quantitative Determination of B-Vitamins in Nutritional Supplements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhandari, Deepak; Van Berkel, Gary J

    2012-01-01

    The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45more » min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.« less

  7. Optimization of large-volume injection for the determination of polychlorinated biphenyls in children's fast-food menus by low-resolution mass spectrometry.

    PubMed

    Esteve-Turrillas, Francesc A; Caupos, Emilie; Llorca, Isabel; Pastor, Agustín; de la Guardia, Miguel

    2008-03-26

    This study includes the determination of five indicator polychlorinated biphenyls (PCBs) (52, 101, 153, 138, and 180), six non-ortho PCBs (35, 80, 81, 77, 126, and 169), and two mono-ortho PCBs (28 and 118) in fast food for children. A freeze-dried sample of 10 g is extracted by using pressurized n-hexane in two 5 min cycles at 120 degrees C and 100 mbar. Fatty extracts were cleaned up by means of acetonitrile/n-hexane partitioning and gel-permeation chromatography. The fractionation of non-ortho, mono-ortho, and indicator PCBs was made on graphitized carbon solid-phase extraction cartridges by using n-hexane, n-hexane/toluene (99:1, v/v), and toluene as elution solvents. Gas chromatography coupled to tandem mass spectrometry and large-volume injections with a programmed-temperature vaporizer (PTV-LV) were used to increase sensitivity and selectivity of the PCB determination. The PTV-LV injection settings, that is, vaporizing temperature, vaporizing time, and purge flow, were optimized by using a central composite design. A 15-40 times increased sensitivity was reached as compared with that obtained with the conventional 1 microL splitless injection. The limits of detection achieved were between 0.3 and 1.2 pg/g, and repeatability data, as relative standard deviation varied, ranged from 2 to 9% for the 0.05 ng/mL PCB level.

  8. Spatial and Temporal Distribution of Imidacloprid Within the Crown of Eastern Hemlock

    PubMed Central

    Turcotte, Richard M.; Lagalante, Anthony; Jones, Jonathan; Cook, Frank; Elliott, Thomas; Billings, Anthony A.

    2017-01-01

    Systemic imidacloprid is the most widely used insecticide to control the hemlock woolly adelgid, Adelges tsugae Annand (Hemiptera: Adelgidae), an exotic pest of eastern hemlock, Tsuga canadensis (L.) Carriére in the United States. This study was conducted to 1) determine the effect of treatment timing (spring vs. fall) and application method (trunk injection vs. soil injection) on the spatial and temporal distribution of imidacloprid within the crown of A. tsugae-free eastern hemlock using a competitive enzyme-linked immunosorbent assay (ELISA), 2) compare ELISA to gas chromatography-mass spectrometry (GC/MS) for the detection of imidacloprid in xylem fluid, and 3) determine the concentration of imidacloprid in leaf tissue using high performance liquid chromatography with tandem mass spectrometric (LC/MS/MS) detection methods. Xylem fluid concentrations of imidacloprid were found to be significantly higher for spring applications than for fall applications and for trunk injections than soil injections in the first year posttreatment. A total of 69% of samples analyzed by ELISA gave 1.8 times higher concentrations of imidacloprid than those found by GC/MS, leading to evidence of a matrix effect and overestimation of imidacloprid in xylem fluid by ELISA. A comparison of the presence of imidacloprid with xylem fluid and in leaf tissue on the same branch showed significant differences, suggesting that imidacloprid moved intermittently within the crown of eastern hemlock. PMID:28130463

  9. Preparation, in vitro release, and pharmacokinetics in rabbits of lyophilized injection of sorafenib solid lipid nanoparticles

    PubMed Central

    Zhang, Hong; Zhang, Fu-Ming; Yan, Shi-Jun

    2012-01-01

    Sorafenib solid lipid nanoparticles (S-SLN) were prepared by emulsion evaporation–solidification at low temperature. Morphology was examined by transmission electron microscope. Particle size and zeta potential were determined by laser granularity equipment. Encapsulation efficiency (EE) was detected by Sephadex gel chromatography and high-performance liquid chromatography (HPLC). The in vitro release profile of S-SLN was studied with dialysis technology. The lyophilized injection of S-SLN was prepared by freeze drying and analyzed by differential scanning calorimetry. The plasma concentration of sorafenib in blood was determined by HPLC. The solid lipid nanoparticles assumed a spherical shape with an even distribution of diameter and particle size 108.23 ± 7.01 nm (n = 3). The polydispersity index, zeta potential, and EE were determined to be 0.25 ± 0.02, −16.37 ± 0.65 mV, and 93.49% ± 1.87%, respectively (n = 3). The in vitro release accorded with the Weibull distribution model. An equal volume of 15% (w/v) mannitol performed better as the protective agent for a lyophilized injection of S-SLN with a new material phase formation. The pharmacokinetic processes of sorafenib solution and lyophilized injection of S-SLN in vivo were in accordance with the two-compartment and one-compartment models, respectively. S-SLN nanoparticles are thus considered a promising drug-delivery system. PMID:22787390

  10. Post-Injection Delirium/Sedation Syndrome after Olanzapine Long-Acting Intramuscular Injection - Who is at Risk?

    PubMed

    Łukasik-Głębocka, Magdalena; Sommerfeld, Karina; Teżyk, Artur; Panieński, Paweł; Żaba, Czesław; Zielińska-Psuja, Barbara

    2015-09-01

    The post-injection olanzapine delirium/sedation syndrome (PDSS) was observed in a 60-year-old Caucasian, schizophrenic, non-smoker and underweight [body mass index (BMI), 18.2 kg/m(2) ] women after the fourth intramuscular injection of 405 mg olanzapine pamoate. Clinical symptoms of PDSS were similar to those of acute oral olanzapine intoxication. The patient received supportive treatment and recovered fully. High olanzapine concentrations in serum, with maximum level of 698 ng/mL, were confirmed by liquid chromatography with tandem mass spectrometry (LC-MS/MS). The authors wonder whether a low BMI and advanced age may predispose patients to PDSS occurrence. © 2015 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  11. Analysis of catecholamines in urine by unique LC/MS suitable ion-pairing chromatography.

    PubMed

    Bergmann, Marianne L; Sadjadi, Seyed; Schmedes, Anne

    2017-07-01

    The catecholamines, epinephrine (E) and norepinephrine (NE) are small polar, hydrophilic molecules, posing significant challenges to liquid chromatography - tandem mass spectrometry (LC-MS/MS) method development. Specifically, these compounds show little retention on conventional reversed-phase liquid chromatography columns. This work presents development and validation of an LC-MS/MS method for determining catecholamines in urine, based on a new approach to ion-pairing chromatography (IPC), in which the ion-pairing reagent (IPR), 1-Heptane Sulfonic Acid (HSA), is added to the extracted samples instead of the mobile phases. A Hamilton STARlet workstation carried out the solid phase extraction of urine samples. The extracted samples were diluted with 60mmol/L HSA and injected on a Kinetex core-shell biphenyl column with conventional LC-MS/MS suitable mobile phases. Chromatographic separation of E and NE was achieved successfully with very stable retention times (RT). In 484 injections, the RTs were steady with a CV of less than ±4%. Furthermore, HSA was separated from E and NE, allowing HSA to be diverted to waste instead of entering the mass spectrometer ion chamber. The method was validated with good analytical performance, and even though the analysis for urinary catecholamines is increasingly being replaced by plasma free metanephrines in diagnosing pheochromocytomas, this work represents the application of a new analytical technique that can be transferred to other small polar molecules, that are difficult to chromatograph on traditional reversed phase columns. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Phantom auditory sensation in rats: an animal model for tinnitus.

    PubMed

    Jastreboff, P J; Brennan, J F; Coleman, J K; Sasaki, C T

    1988-12-01

    In order to measure tinnitus induced by sodium salicylate injections, 84 pigmented rats, distributed among 14 groups in five experiments, were used in a conditioned suppression paradigm. In Experiment 1, all groups were trained with a conditioned stimulus (CS) consisting of the offset of a continuous background noise. One group began salicylate injections before Pavlovian training, a second group started injections after training, and a control group received daily saline injections. Resistance to extinction was profound when injections started before training, but minimal when initiated after training, which suggests that salicylate-induced effects acquired differential conditioned value. In Experiment 2 we mimicked the salicylate treatments by substituting a 7 kHz tone in place of respective injections, resulting in effects equivalent to salicylate-induced behavior. In a third experiment we included a 3 kHz CS, and again replicated the salicylate findings. In Experiment 4 we decreased the motivational level, and the sequential relation between salicylate-induced effects and suppression training was retained. Finally, no salicylate effects emerged when the visual modality was used. These findings support the demonstration of phantom auditory sensations in animals.

  13. Effects of neostriatal 6-OHDA lesion on performance in a rat sequential reaction time task.

    PubMed

    Domenger, D; Schwarting, R K W

    2008-10-31

    Work in humans and monkeys has provided evidence that the basal ganglia, and the neurotransmitter dopamine therein, play an important role for sequential learning and performance. Compared to primates, experimental work in rodents is rather sparse, largely due to the fact that tasks comparable to the human ones, especially serial reaction time tasks (SRTT), had been lacking until recently. We have developed a rat model of the SRTT, which allows to study neural correlates of sequential performance and motor sequence execution. Here, we report the effects of dopaminergic neostriatal lesions, performed using bilateral 6-hydroxydopamine injections, on performance of well-trained rats tested in our SRTT. Sequential behavior was measured in two ways: for one, the effects of small violations of otherwise well trained sequences were examined as a measure of attention and automation. Secondly, sequential versus random performance was compared as a measure of sequential learning. Neurochemically, the lesions led to sub-total dopamine depletions in the neostriatum, which ranged around 60% in the lateral, and around 40% in the medial neostriatum. These lesions led to a general instrumental impairment in terms of reduced speed (response latencies) and response rate, and these deficits were correlated with the degree of striatal dopamine loss. Furthermore, the violation test indicated that the lesion group conducted less automated responses. The comparison of random versus sequential responding showed that the lesion group did not retain its superior sequential performance in terms of speed, whereas they did in terms of accuracy. Also, rats with lesions did not improve further in overall performance as compared to pre-lesion values, whereas controls did. These results support previous results that neostriatal dopamine is involved in instrumental behaviour in general. Also, these lesions are not sufficient to completely abolish sequential performance, at least when acquired before lesion as tested here.

  14. Determination of ephedrine and pseudoephedrine by field-amplified sample injection capillary electrophoresis.

    PubMed

    Deng, Dongli; Deng, Hao; Zhang, Lichun; Su, Yingying

    2014-04-01

    A simple and rapid capillary electrophoresis method was developed for the separation and determination of ephedrine (E) and pseudoephedrine (PE) in a buffer solution containing 80 mM of NaH2PO4 (pH 3.0), 15 mM of β-cyclodextrin and 0.3% of hydroxypropyl methylcellulose. The field-amplified sample injection (FASI) technique was applied to the online concentration of the alkaloids. With FASI in the presence of a low conductivity solvent plug (water), an approximately 1,000-fold improvement in sensitivity was achieved without any loss of separation efficiency when compared to conventional sample injection. Under these optimized conditions, a baseline separation of the two analytes was achieved within 16 min and the detection limits for E and PE were 0.7 and 0.6 µg/L, respectively. Without expensive instruments or labeling of the compounds, the limits of detection for E and PE obtained by the proposed method are comparable with (or even lower than) those obtained by capillary electrophoresis laser-induced fluorescence, liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry. The method was validated in terms of precision, linearity and accuracy, and successfully applied for the determination of the two alkaloids in Ephedra herbs.

  15. Evaluation of phenolic compounds in virgin olive oil by direct injection in high-performance liquid chromatography with fluorometric detection.

    PubMed

    Selvaggini, Roberto; Servili, Maurizio; Urbani, Stefania; Esposto, Sonia; Taticchi, Agnese; Montedoro, GianFrancesco

    2006-04-19

    Hydrophilic phenols are the most abundant natural antioxidants of virgin olive oil (VOO), in which tocopherols and carotenes are also present. The prevalent classes of hydrophilic phenols found in VOO are phenyl alcohols, phenolic acids, secoiridoids such as the dialdehydic form of decarboxymethyl elenolic acid linked to (3,4-dihydroxyphenyl)ethanol or (p-hydroxypheny1)ethanol (3,4-DHPEA-EDA or p-HPEA-EDA) and an isomer of the oleuropein aglycon (3,4-DHPEA-EA), lignans such as (+)-1-acetoxypinoresinol and (+)-pinoresinol, and flavonoids. A new method for the analysis of VOO hydrophilic phenols by direct injection in high-performance liquid chromatography (HPLC) with the use of a fluorescence detector (FLD) has been proposed and compared with the traditional liquid-liquid extraction technique followed by the HPLC analysis utilizing a diode array detector (DAD) and a FLD. Results show that the most important classes of phenolic compounds occurring in VOO can be evaluated using HPLC direct injection. The efficiency of the new method, as compared to the liquid-liquid extraction, was higher to quantify phenyl alcohols, lignans, and 3,4-DHPEA-EA and lower for the evaluation of 3,4-DHPEA-EDA and p-HPEA-EDA.

  16. Thin layer chromatography-ion mobility spectrometry (TLC-IMS).

    PubMed

    Ilbeigi, Vahideh; Tabrizchi, Mahmoud

    2015-01-06

    Ion mobility spectrometry (IMS) is a fast and sensitive analytical method which operates at the atmospheric pressure. To enhance the capability of IMS for the analysis of mixtures, it is often used with preseparation techniques, such as GC or HPLC. Here, we report for the first time the coupling of the thin-layer chromatography and IMS. A variety of coupling schemes were tried that included direct electrospray from the TLC strip tip, indirect electrospray from a needle connected to the TLC strip, introducing the moving solvent into the injection port, and, the simplest way, offline introduction of scratched or cut pieces of strips into the IMS injection port. In this study a special solvent tank was designed and the TLC strip was mounted horizontally where the solvent would flow down. A very small funnel right below the TLC tip collected the solvent and transferred it to a needle via a capillary tubing. Using the TLC-ESI-IMS technique, acceptable separations were achieved for two component mixtures of morphine-papaverine and acridine-papaverine. A special injection port was designed to host the pieces cut off the TLC. The method was successfully used to identify each spot on the TLC by IMS in a few seconds.

  17. Improving the accuracy of hyaluronic acid molecular weight estimation by conventional size exclusion chromatography.

    PubMed

    Shanmuga Doss, Sreeja; Bhatt, Nirav Pravinbhai; Jayaraman, Guhan

    2017-08-15

    There is an unreasonably high variation in the literature reports on molecular weight of hyaluronic acid (HA) estimated using conventional size exclusion chromatography (SEC). This variation is most likely due to errors in estimation. Working with commercially available HA molecular weight standards, this work examines the extent of error in molecular weight estimation due to two factors: use of non-HA based calibration and concentration of sample injected into the SEC column. We develop a multivariate regression correlation to correct for concentration effect. Our analysis showed that, SEC calibration based on non-HA standards like polyethylene oxide and pullulan led to approximately 2 and 10 times overestimation, respectively, when compared to HA-based calibration. Further, we found that injected sample concentration has an effect on molecular weight estimation. Even at 1g/l injected sample concentration, HA molecular weight standards of 0.7 and 1.64MDa showed appreciable underestimation of 11-24%. The multivariate correlation developed was found to reduce error in estimations at 1g/l to <4%. The correlation was also successfully applied to accurately estimate the molecular weight of HA produced by a recombinant Lactococcus lactis fermentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Microbial Degradation of Alkyl Carbazoles in Norman Wells Crude Oil

    PubMed Central

    Fedorak, Phillip M.; Westlake, Donald W. S.

    1984-01-01

    Norman Wells crude oil was fractionated by sequential alumina and silicic acid column chromatography methods. The resulting nitrogen-rich fraction was analyzed by gas chromatography-mass spectrometry and showed 26 alkyl (C1 to C5) carbazoles to be the predominant compounds. An oil-degrading mixed bacterial culture was enriched on carbazole to enhance its ability to degrade nitrogen heterocycles. This culture was used to inoculate a series of flasks of mineral medium and Norman Wells crude oil. Residual oil was recovered from these cultures after incubation at 25°C for various times. The nitrogen-rich fraction was analyzed by capillary gas chromatography, using a nitrogen-specific detector. Most of the C1-, C2-, and C3- carbazoles and one of the C4-isomers were degraded within 8 days. No further degradation occurred when incubation was extended to 28 days. The general order of susceptibility of the isomers to biodegradation was C1 > C2 > C3 > C4. The carbazole-enriched culture was still able to degrade n-alkanes, isoprenoids, aromatic hydrocarbons, and sulfur heterocycles in the crude soil. PMID:16346524

  19. Evaluation of automated sample preparation, retention time locked gas chromatography-mass spectrometry and data analysis methods for the metabolomic study of Arabidopsis species.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Rumpel, Klaus; Dugardeyn, Jasper; Van Der Straeten, Dominique; Xu, Guowang; Sandra, Pat

    2011-05-27

    In this paper, automated sample preparation, retention time locked gas chromatography-mass spectrometry (GC-MS) and data analysis methods for the metabolomics study were evaluated. A miniaturized and automated derivatisation method using sequential oximation and silylation was applied to a polar extract of 4 types (2 types×2 ages) of Arabidopsis thaliana, a popular model organism often used in plant sciences and genetics. Automation of the derivatisation process offers excellent repeatability, and the time between sample preparation and analysis was short and constant, reducing artifact formation. Retention time locked (RTL) gas chromatography-mass spectrometry was used, resulting in reproducible retention times and GC-MS profiles. Two approaches were used for data analysis. XCMS followed by principal component analysis (approach 1) and AMDIS deconvolution combined with a commercially available program (Mass Profiler Professional) followed by principal component analysis (approach 2) were compared. Several features that were up- or down-regulated in the different types were detected. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Comparison of two cell lysis procedures for recovery of microcystins in water samples from silver lake in Dover, Delaware, with microcystin producing cyanobacterial accumulations

    USGS Publications Warehouse

    Loftin, Keith A.; Meyer, Michael T.; Rubio, Fernando; Kamp, Lisa; Humphries, Edythe; Whereat, Ed

    2008-01-01

    A collaboration was developed between Abraxis, LLC, the State of Delaware Department of Natural Resources and Environmental Control Division of Water Resources Environmental Laboratory, the University of Delaware, and the United States Geological Survey to investigate the efficacy of the QuikLyse procedure developed by Abraxis, LLC as an alternative cell-lysis technique suitable for use with an existing liquid chromatography/tandem mass spectrometry research method developed at the United States Geological Survey Organic Geochemistry Research Laboratory to analyze cyanotoxins. A comparison of three sequential freeze/thaw cycles versus QuikLyse, a proprietary chemical lysis procedure was conducted on four water samples collected from Silver Lake in Dover, Delaware. Results from the Abraxis Microcystins-DM enzyme-linked immunosorbent assay and liquid chromatography/tandem mass spectrometry were tabulated as a function of the cell lysis technique. Stastical comparison of percent relative standard deviations showed no significant difference (alpha = 0.05) between both cell-lysis techniques when measured by enzyme-linked immunosorbent assay or liquid chromatography/tandem mass spectrometry for three of the four samples.

  1. Validation of a method for simultaneous determination of nitroimidazoles, benzimidazoles and chloramphenicols in swine tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Xia, Xi; Wang, Yuanyuan; Wang, Xia; Li, Yun; Zhong, Feng; Li, Xiaowei; Huang, Yaoling; Ding, Shuangyang; Shen, Jianzhong

    2013-05-31

    This paper presents a sensitive and confirmatory multi-residue method for the analysis of 23 veterinary drugs and metabolites belonging to three classes (nitroimidazoles, benzimidazoles, and chloramphenicols) in porcine muscle, liver, and kidney. After extracted with ethyl acetate and basic ethyl acetate sequentially, the crude extracts were defatted with hexane and further purified using Oasis MCX solid-phase extraction cartridges. Rapid determination was carried out by ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry. Data acquisition was performed under positive and negative mode simultaneously. Recoveries based on matrix-matched calibrations for meat, liver, and kidney ranged from 50.6 to 108.1%. The method quantification limits were in the range of 3-100ng/kg. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Structure of a Rhamnogalacturonan Fragment from Apple Pectin: Implications for Pectin Architecture

    DOE PAGES

    Wu, Xiangmei; Mort, Andrew

    2014-01-01

    A comore » mmercial apple pectin was sequentially digested with the cloned enzymes endopolygalacturonase, galactanase, arabinofuranosidase, xylogalacturonase, and rhamnogalacturonan hydrolase. The rhamnogalacturonan hydrolase-generated oligosaccharides were separated by ultrafiltration, anion exchange, and size-exclusion chromatography. Fractions from the ion exchange chromatography were pooled, lyophilized, and screened by MALDI-TOF MS. An oligosaccharide (RGP14P3) was identified and its structure, α -D-Gal p A- ( 1 → 2 ) - α -L-Rha p - ( 1 → 4 ) - α -D-Gal p A- ( 1 → 2 ) - α -L-Rha p - ( 1 → 4 ) - α -D-Gal p A, determined by 1D and 2D NMR spectrometry. This oligosaccharide probably represents a direct connection between homogalacturonan and rhamnogalacturonan in pectin. Alternatively, it could indicate that the nonreducing end of rhamnogalacturonan starts with a galacturonic acid residue.« less

  3. Qualitative and quantitative temporal analysis of licit and illicit drugs in wastewater in Australia using liquid chromatography coupled to mass spectrometry.

    PubMed

    Bade, Richard; White, Jason M; Gerber, Cobus

    2018-01-01

    The combination of qualitative and quantitative bimonthly analysis of pharmaceuticals and illicit drugs using liquid chromatography coupled to mass spectrometry is presented. A liquid chromatography-quadrupole time of flight instrument equipped with Sequential Window Acquisition of all THeoretical fragment-ion spectra (SWATH) was used to qualitatively screen 346 compounds in influent wastewater from two wastewater treatment plants in South Australia over a 14-month period. A total of 100 compounds were confirmed and/or detected using this strategy, with 61 confirmed in all samples including antidepressants (amitriptyline, dothiepin, doxepin), antipsychotics (amisulpride, clozapine), illicit drugs (cocaine, methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA)), and known drug adulterants (lidocaine and tetramisole). A subset of these compounds was also included in a quantitative method, analyzed on a liquid chromatography-triple quadrupole mass spectrometer. The use of illicit stimulants (methamphetamine) showed a clear decrease, levels of opioid analgesics (morphine and methadone) remained relatively stable, while the use of new psychoactive substances (methylenedioxypyrovalerone (MDPV) and Alpha PVP) varied with no visible trend. This work demonstrates the value that high-frequency sampling combined with quantitative and qualitative analysis can deliver. Graphical abstract Temporal analysis of licit and illicit drugs in South Australia.

  4. Separation and preconcentration of the rare-earth elements and yttrium from geological materials by ion-exchange and sequential acid elution

    USGS Publications Warehouse

    Crock, J.G.; Lichte, F.E.; Riddle, G.O.; Beech, C.L.

    1986-01-01

    The abundance of rare-earth elements (REE) and yttrium in geological materials is generally low, and most samples contain elements that interfere in the determination of the REE and Y, so a separation and/or preconcentration step is often necessary. This is often achieved by ion-exchange chromatography with either nitric or hydrochloric acid. It is advantageous, however, to use both acids sequentially. The final solution thus obtained contains only the REE and Y, with minor amounts of Al, Ba, Ca, Sc, Sr and Ti. Elements that potentially interfere, such as Be, Co, Cr, Fe, Mn, Th, U, V and Zr, are virtually eliminated. Inductively-coupled argon plasma atomic-emission spectroscopy can then be used for a final precise and accurate measurement. The method can also be used with other instrumental methods of analysis. ?? 1986.

  5. Screening antimutagenic and antiproliferative properties of extracts isolated from Jackfruit pulp (Artocarpus heterophyllus Lam).

    PubMed

    Ruiz-Montañez, G; Burgos-Hernández, A; Calderón-Santoyo, M; López-Saiz, C M; Velázquez-Contreras, C A; Navarro-Ocaña, A; Ragazzo-Sánchez, J A

    2015-05-15

    The present focused on the study of the antimutagenic and antiproliferative potential of pulp Jackfruit (Artocarpus heterophyllus Lam) extract, using Salmonella typhimurium tester strains TA98 and TA100 with metabolic activation (S9) and a cancer cell line M12.C3.F6 (murine B-cell lymphoma), respectively. Jackfruit pulp extract was sequentially fractionated by chromatography (RP-HPLC) and each fraction was tested for antimutagenic and antiproliferative activities. The organic extracts obtained from Jackfruit pulp reduced the number of revertants caused by aflatoxin B1 (AFB1) and proliferation of cells M12.C3.F6; a dose-response relationship was showed. Sequential RP-HPLC fractionation of the active extracts produced both antimutagenic and/or antiproliferative fractions. These results suggested that the Jackfruit contained compounds with chemoprotective properties to reduce the mutagenicity of AFB1, also proliferation of a cancer cell line. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Effect of nicergoline on cerebral blood flow

    PubMed Central

    Iliff, L. D.; Boulay, G. H. Du; Marshall, John; Russell, R. W. Ross; Symon, Lindsay

    1977-01-01

    Cerebral blood flow (CBF) was measured before and after intravenous injection of the cerebral vasodilator nicergoline in 13 patients with cerebrovascular disease. CBF increased in seven. The possibility that the effect of the drug in the remainder may have been masked by a fall of CBF which occurs during sequential measurement of patients at rest is discussed. PMID:925694

  7. Remediation of DNAPL through Sequential In Situ Chemical Oxidation and Bioaugmentation

    DTIC Science & Technology

    2009-04-01

    Specific Electrode Field Field-filtered, ICP - PSC 0.05 mg/L 125 mL plastic nitric acid to pHɚ 28 days cool to 4oC Ion Chromatography 25310 C PSC 0.2...oxidized by MnO2 at a significant rate; however, MnO2 reacted rapidly with oxalic acid ; • Complete dechlorination occurred only in microcosms...controller PLFA phospholipid fatty acid ppb parts per billion PTA pilot test area PVC polyvinyl chloride QAPP quality assurance project plan QA

  8. Cyclic nucleotide content of tobacco BY-2 cells.

    PubMed

    Richards, Helen; Das, Swadipa; Smith, Christopher J; Pereira, Louisa; Geisbrecht, Alan; Devitt, Nicola J; Games, David E; van Geyschem, Jan; Gareth Brenton, A; Newton, Russell P

    2002-11-01

    The cyclic nucleotide content of cultured tobacco bright yellow-2 (BY-2) cells was determined, after freeze-killing, perchlorate extraction and sequential chromatography, by radioimmunoassay. The identities of the putative cyclic nucleotides, adenosine 3',5'-cyclic monophosphate (cyclic AMP), guanosine 3',5'-cyclic monophosphate (cyclic GMP) and cytidine 3',5'-cyclic monophosphate (cyclic CMP) were unambiguously confirmed by tandem mass spectrometry. The potential of BY-2 cell cultures as a model system for future investigations of cyclic nucleotide function in higher plants is discussed.

  9. A direct and fast method to monitor lipid oxidation progress in model fatty acid methyl esters by high-performance size-exclusion chromatography.

    PubMed

    Márquez-Ruiz, G; Holgado, F; García-Martínez, M C; Dobarganes, M C

    2007-09-21

    A new method based on high-performance size-exclusion chromatography (HPSEC) is proposed to quantitate primary and secondary oxidation compounds in model fatty acid methyl esters (FAMEs). The method consists on simply injecting an aliquot sample in HPSEC, without preliminary isolation procedures neither addition of standard internal. Four groups of compounds can be quantified, namely, unoxidised FAME, oxidised FAME monomers including hydroperoxides, FAME dimers and FAME polymers. Results showed high repeatability and sensitivity, and substantial advantages versus determination of residual substrate by gas-liquid chromatography. Applicability of the method is shown through selected data obtained by numerous oxidation experiments on pure FAME, mainly methyl linoleate, at ambient and moderate temperatures.

  10. Determination of erythromycin in human plasma, using column liquid chromatography with a polymeric packing material, alkaline mobile phase and amperometric detection.

    PubMed

    Nilsson, L G; Walldorf, B; Paulsen, O

    1987-12-25

    A method based on column liquid chromatography was developed for determination of plasma concentrations of erythromycin. PRP-1, a polymeric type of packing material suitable for chromatography and amperometric detection at high pH, was used. The effect of pH on the column performance and on the electrochemical response was studied. A pH of ca. 10 was found to be optimal. After extraction with tert.-butyl methyl ether, plasma concentrations down to 0.2 mumol/l could be measured, using automated sample injection. Oleandomycin was used as internal standard. The method was used for determination of plasma concentrations in a pharmacokinetic study under steady-state conditions.

  11. Identification of inorganic improvised explosive devices using sequential injection capillary electrophoresis and contactless conductivity detection.

    PubMed

    Blanco, Gustavo A; Nai, Yi H; Hilder, Emily F; Shellie, Robert A; Dicinoski, Greg W; Haddad, Paul R; Breadmore, Michael C

    2011-12-01

    A simple sequential injection capillary electrophoresis (SI-CE) instrument with capacitively coupled contactless conductivity detection (C(4)D) has been developed for the rapid separation of anions relevant to the identification of inorganic improvised explosive devices (IEDs). Four of the most common explosive tracer ions, nitrate, perchlorate, chlorate, and azide, and the most common background ions, chloride, sulfate, thiocyanate, fluoride, phosphate, and carbonate, were chosen for investigation. Using a separation electrolyte comprising 50 mM tris(hydroxymethyl)aminomethane, 50 mM cyclohexyl-2-aminoethanesulfonic acid, pH 8.9 and 0.05% poly(ethyleneimine) (PEI) in a hexadimethrine bromide (HDMB)-coated capillary it was possible to partially separate all 10 ions within 90 s. The combination of two cationic polymer additives (PEI and HDMB) was necessary to achieve adequate selectivity with a sufficiently stable electroosmotic flow (EOF), which was not possible with only one polymer. Careful optimization of variables affecting the speed of separation and injection timing allowed a further reduction of separation time to 55 s while maintaining adequate efficiency and resolution. Software control makes high sample throughput possible (60 samples/h), with very high repeatability of migration times [0.63-2.07% relative standard deviation (RSD) for 240 injections]. The separation speed does not compromise sensitivity, with limits of detection ranging from 23 to 50 μg·L(-1) for all the explosive residues considered, which is 10× lower than those achieved by indirect absorbance detection and 2× lower than those achieved by C(4)D using portable benchtop instrumentation. The combination of automation, high sample throughput, high confidence of peak identification, and low limits of detection makes this methodology ideal for the rapid identification of inorganic IED residues.

  12. Coupled Hydro-Mechanical Modeling of Fluid Geological Storage

    NASA Astrophysics Data System (ADS)

    Castelletto, N.; Garipov, T.; Tchelepi, H. A.

    2013-12-01

    The accurate modeling of the complex coupled physical processes occurring during the injection and the post-injection period is a key factor for assessing the safety and the feasibility of anthropogenic carbon dioxide (CO2) sequestration in subsurface formations. In recent years, it has become widely accepted the importance of the coupling between fluid flow and geomechanical response in constraining the sustainable pressure buildup caused by fluid injection relative to the caprock sealing capacity, induced seismicity effects and ground surface stability [e.g., Rutqvist, 2012; Castelletto et al., 2013]. Here, we present a modeling approach based on a suitable combination of Finite Volumes (FVs) and Finite Elements (FEs) to solve the coupled system of partial differential equations governing the multiphase flow in a deformable porous medium. Specifically, a FV method is used for the flow problem while the FE method is adopted to address the poro-elasto-plasticity equations. The aim of the present work is to compare the performance and the robustness of unconditionally stable sequential-implicit schemes [Kim et al., 2011] and the fully-implicit method in solving the algebraic systems arising from the discretization of the governing equations, for both normally conditioned and severely ill-conditioned problems. The two approaches are tested against well-known analytical solutions and experimented with in a realistic application of CO2 injection in a synthetic aquifer. References: - Castelletto N., G. Gambolati, and P. Teatini (2013), Geological CO2 sequestration in multi-compartment reservoirs: Geomechanical challenges, J. Geophys. Res. Solid Earth, 118, 2417-2428, doi:10.1002/jgrb.50180. - Kim J., H. A. Tchelepi, and R. Juanes (2011), Stability, accuracy and efficiency of sequential methods for coupled flow and geomechanics, SPE J., 16(2), 249-262. - Rutqvist J. (2012), The geomechanics of CO2 storage in deep sedimentary formations, Geotech. Geol. Eng., 30, 525-551.

  13. Sequential Systemic Administrations of Combretastatin A4 Phosphate and Radioiodinated Hypericin Exert Synergistic Targeted Theranostic Effects with Prolonged Survival on SCID Mice Carrying Bifocal Tumor Xenografts

    PubMed Central

    Li, Junjie; Cona, Marlein Miranda; Chen, Feng; Feng, Yuanbo; Zhou, Lin; Zhang, Guozhi; Nuyts, Johan; de Witte, Peter; Zhang, Jian; Yu, Jie; Oyen, Raymond; Verbruggen, Alfons; Ni, Yicheng

    2013-01-01

    Objectives: Based on the soil-to-seeds principle, we explored the small-molecular sequential dual-targeting theranostic strategy (SMSDTTS) for prolonged survival and imaging detectability in a xenograft tumor model. Materials and Methods: Thirty severe combined immunodeficiency (SCID) mice bearing bilateral radiation-induced fibrosarcoma-1 (RIF-1) subcutaneously were divided into group A of SMSDTTS with sequential intravenous injections of combretastatin A4 phosphate (CA4P) and 131I-iodohypericin (131I-Hyp) at a 24 h interval; group B of single targeting control with CA4P and vehicle of 131I-Hyp; and group C of vehicle control (10 mice per group). Tumoricidal events were monitored by in vivo magnetic resonance imaging (MRI) and planar gamma scintiscan, and validated by ex vivo autoradiography and histopathology. Besides, 9 mice received sequential intravenous injections of CA4P and 131I-Hyp were subjected to biodistribution analysis at 24, 72 and 120 h. Results: Gamma counting revealed fast clearance of 131I-Hyp from normal organs but intense accumulation in necrotic tumor over 120 h. After only one treatment, significantly prolonged survival (p<0.001) was found in group A compared to group B and C with median survival of 33, 22, and 21 days respectively. Tumor volume on day 15 was 2.0 ± 0.89, 5.66 ± 1.66, and 5.02 ± 1.0 cm3 with tumor doubling time 7.8 ± 2.8, 4.4 ± 0.67, and 4.5 ± 0.5 days respectively. SMSDTTS treated tumors were visualized as hot spots on gamma scintiscans, and necrosis over tumor ratio remained consistently high on MRI, autoradiography and histology. Conclusion: The synergistic antitumor effects, multifocal targetability, simultaneous theranostic property, and good tolerance of the SMSDTTS were evident in this experiment, which warrants further development for preclinical and clinical applications. PMID:23423247

  14. Sequential Bayesian Geostatistical Inversion and Evaluation of Combined Data Worth for Aquifer Characterization at the Hanford 300 Area

    NASA Astrophysics Data System (ADS)

    Murakami, H.; Chen, X.; Hahn, M. S.; Over, M. W.; Rockhold, M. L.; Vermeul, V.; Hammond, G. E.; Zachara, J. M.; Rubin, Y.

    2010-12-01

    Subsurface characterization for predicting groundwater flow and contaminant transport requires us to integrate large and diverse datasets in a consistent manner, and quantify the associated uncertainty. In this study, we sequentially assimilated multiple types of datasets for characterizing a three-dimensional heterogeneous hydraulic conductivity field at the Hanford 300 Area. The datasets included constant-rate injection tests, electromagnetic borehole flowmeter tests, lithology profile and tracer tests. We used the method of anchored distributions (MAD), which is a modular-structured Bayesian geostatistical inversion method. MAD has two major advantages over the other inversion methods. First, it can directly infer a joint distribution of parameters, which can be used as an input in stochastic simulations for prediction. In MAD, in addition to typical geostatistical structural parameters, the parameter vector includes multiple point values of the heterogeneous field, called anchors, which capture local trends and reduce uncertainty in the prediction. Second, MAD allows us to integrate the datasets sequentially in a Bayesian framework such that it updates the posterior distribution, as a new dataset is included. The sequential assimilation can decrease computational burden significantly. We applied MAD to assimilate different combinations of the datasets, and then compared the inversion results. For the injection and tracer test assimilation, we calculated temporal moments of pressure build-up and breakthrough curves, respectively, to reduce the data dimension. A massive parallel flow and transport code PFLOTRAN is used for simulating the tracer test. For comparison, we used different metrics based on the breakthrough curves not used in the inversion, such as mean arrival time, peak concentration and early arrival time. This comparison intends to yield the combined data worth, i.e. which combination of the datasets is the most effective for a certain metric, which will be useful for guiding the further characterization effort at the site and also the future characterization projects at the other sites.

  15. Deltoid Injections of Risperidone Long-acting Injectable in Patients with Schizophrenia

    PubMed Central

    Quiroz, Jorge A.; Rusch, Sarah; Thyssen, An; Kushner, Stuart

    2011-01-01

    Background Risperidone long-acting injectable was previously approved for treatment of schizophrenia as biweekly injections in the gluteal muscle only. We present data on local injection-site tolerability and safety of risperidone long-acting injectable and comparability of systemic exposure of deltoid versus gluteal injections. Methods Risperidone long-acting injectable was administered in an open-label, single-dose, two-way crossover study, with patients randomized to receive either 25mg gluteal/37.5mg deltoid crossover in two treatment periods or 50mg gluteal/50mg deltoid injections crossover; each treatment period was separated by an 85-day observation period (Study 1) and an open-label, multiple-dose study (4 sequential 37.5mg or 50mg deltoid injections every 2 weeks) (Study 2). The pharmacokinetic results from both the studies have already been published. Results In Study 1 (n=170), the majority of patients had no local injection-site findings, based on investigator and patient-rated evaluations. In Study 2 (n=53), seven of the 51 patients who received at least two deltoid injections discontinued (primary endpoint). However, none of the discontinuations were due to injection-site related reasons. The 90-percent upper confidence limit of the true proportion of injection-site issue withdrawals was 5.7 percent. No moderate or severe injection-site reactions were reported. Conclusion Intramuscular injections via the deltoid and gluteal sites are equivalent routes of administration of risperidone long-acting injectable with respect to local injection-site tolerability. The overall safety and tolerability profile of risperidone long-acting injectable was comparable when administered as an intramuscular injection in the deltoid (37.5mg and 50mg) and gluteal (25mg and 50mg) sites. PMID:21779538

  16. [Pharmacokinetics and safety of aripiprazole long-acting injection, following multiple deltoid administrations in schizophrenia patients in Japan].

    PubMed

    Ishigooka, Jun; Noda, Takamasa; Nishiyama, Kosuke; Tamaru, Noriko; Shima, Tomoko; Yamasaki, Yumiko; Tadori, Yoshihiro

    2016-06-01

    Aripiprazole once-monthly (AOM) was previously approved for treatment of schizophrenia as monthly injections in the gluteal muscle. The deltoid muscle provides a more accessible injection site. The present study was conducted in Japanese schizophrenia patients as a 24-week, open-label trial that assessed the pharmacokinetics and safety of 5 sequential doses of AOM 400 mg (AOM 400) once every 4 weeks administered in the deltoid muscle. Patients treated with an oral atypical antipsychotic (other than aripiprazole) continued to receive their pre-study medication up to 14 days after the first AOM 400 injection. The completion rate was 76.5% (n = 13/17). Mean aripiprazole plasma C(min) almost reached steady-state by the fourth AOM 400 injection. After the fifth AOM 400 injection, mean aripiprazole AUC(28d), C(max) and C(min) were 165 μg x h/ml, 331 ng/ml and 201 ng/ml, respectively, which were similar to previously published pharmacokinetic parameters after the fifth gluteal injection of AOM 400. The most common treatment-emergent adverse event (TEAE) was injection site pain (35.3%). Most TEAEs were classified as mild in intensity. In conclusion, the deltoid injection of AOM can be considered an alternative route of administration, as deltoid and gluteal injections are interchangeable in terms of aripiprazole plasma concentrations, with no additional safety issues.

  17. Online spectrophotometric determination of Fe(II) and Fe(III) by flow injection combined with low pressure ion chromatography

    NASA Astrophysics Data System (ADS)

    Chen, Shujuan; Li, Nan; Zhang, Xinshen; Yang, Dongjing; Jiang, Heimei

    2015-03-01

    A simple and new low pressure ion chromatography combined with flow injection spectrophotometric procedure for determining Fe(II) and Fe(III) was established. It is based on the selective adsorption of low pressure ion chromatography column to Fe(II) and Fe(III), the online reduction reaction of Fe(III) and the reaction of Fe(II) in sodium acetate with phenanthroline, resulting in an intense orange complex with a suitable absorption at 515 nm. Various chemical (such as the concentration of colour reagent, eluant and reductive agent) and instrumental parameters (reaction coil length, reductive coil length and wavelength) were studied and were optimized. Under the optimum conditions calibration graph of Fe(II)/Fe(III) was linear in the Fe(II)/Fe(III) range of 0.040-1.0 mg/L. The detection limit of Fe(III) and Fe(II) was respectively 3.09 and 1.55 μg/L, the relative standard deviation (n = 10) of Fe(II) and Fe(III) 1.89% and 1.90% for 0.5 mg/L of Fe(II) and Fe(III) respectively. About 2.5 samples in 1 h can be analyzed. The interfering effects of various chemical species were studied. The method was successfully applied in the determination of water samples.

  18. Identification of di(ethylhexyl) phthalate as impurity in the analysis by using chromatography gas tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Pusfitasari, Eka Dian; Hendarsyah, Hendris; Salahuddin, Ariani, Novita

    2017-01-01

    Di(ethylhexyl) phthalate (DEHP) is a plasticizer commonly used in plastics. Physically DEHP has a low vapor pressure. DEHP can seep into the liquid in direct contact with the plastic wrapping materials, and typically can occur rapidly if extractable into food or non-polar solvents, such as oil, once the food is packaged in PVC packaging materials. DEHP has been analyzed by using gas chromatography which has a high sensitivity level. If the equipment used for the analysis is made from plastic containing DEHP, then it may be possible that DEHP can be extracted and appear on the outcome of the injection. It can interfere with the process of analysis, especially for the analysis of food samples. This study has identified the present of DEHP in the blank injection performed by Gas Chromatography tandem Mass Spectrometry with Selected Ion Monitoring mode (SIM). Researchers are required to verify whether the gas chromatographic system used is ready for the analysis process. In addition, the comparison and calculation of the intensity of the ion fragmentation spectra generated by mass spectrometry detector can be used for the qualitative determination to ensure the presence of the target compound. In this study is also discussed the differences between the high-intensity fragmentation of DEHP and dioctyl phthalate (DOP).

  19. Identification of the Allergenic Ingredients in Reduning Injection by Ultrafiltration and High-Performance Liquid Chromatography.

    PubMed

    Wang, Fang; Li, Cun-yu; Zheng, Yun-feng; Li, Hong-yang; Xiao, Wei; Peng, Guo-ping

    2016-01-01

    Reduning injection is a traditional Chinese medicine injection which has multiple functions such as clearing heat, dispelling wind, and detoxification. Although Reduning injection was widely utilized, reports of its allergenicity emerged one after another. However, there is little research on its allergenic substances. The aim of this study is to evaluate the sensitization of Reduning injection and explore the underlying cause of the anaphylactic reaction. The main ingredients in Reduning injection were analyzed before and after ultrafiltration. Ultrafiltrate Reduning injection, unfiltered Reduning injection, egg albumin, Tween-80, and nine effective components in Reduning injection were utilized to sensitize guinea pigs. The serum 5-hydroxytryptamine level was used to assess the sensitization effect of Reduning injection. We found a significant decrease in Tween-80 content comparing to other components in the injection after ultrafiltration. Unfiltered Reduning injection, Tween-80, chlorogenic acid, and cryptochlorogenin acid caused remarkable anaphylactoid reaction on guinea pigs while ultrafiltration Reduning resulted in a significantly lower degree of sensitization. Our results suggest that ultrafiltration could significantly reduce the sensitization of Reduning injection, which is likely due to the decrease of Tween-80. We also conjectured that the form of chlorogenic acid and cryptochlorogenin acid within the complex solution mixture may also affect the sensitizing effect.

  20. Comparison of liquid chromatographic and bioassay procedures for determining depletion of intramuscularly injected tylosin.

    PubMed

    Moats, W A; Harris, E W; Steele, N C

    1985-01-01

    Crossbred pigs weighing 80-110 kg were injected intramuscularly in the ham with 8.8 mg/kg tylosin. Animals were slaughtered in groups of 3 at intervals of 4 h, and 1, 2, 4, and 8 days after injection, and samples of blood, injected muscle, uninjected muscle, liver, and kidney were analyzed by liquid chromatography (LC) and by bioassay using Sarcina lutea as the test organism. The LC method was far more sensitive with a detection limit of less than 0.1 ppm, while the detection limit by bioassay was about 0.5 ppm in tissue. Results by bioassay and LC sometimes differed considerably for tissue samples. Residues in all tissues were below the tolerance limit of 0.2 ppm at 24 h, except in the injected muscle in one animal. Residues were not detected in any tissue of any animal at 48 h after treatment.

  1. Effect of short-term sequential administration of nonsteroidal anti-inflammatory drugs on the stomach and proximal portion of the duodenum in healthy dogs.

    PubMed

    Dowers, Kristy L; Uhrig, Samantha R; Mama, Khursheed R; Gaynor, James S; Hellyer, Peter W

    2006-10-01

    To evaluate effects of injection with a nonsteroidal anti-inflammatory drug (NSAID) followed by oral administration of an NSAID on the gastrointestinal tract (GIT) of healthy dogs. 6 healthy Walker Hounds. In a randomized, crossover design, dogs were administered 4 treatments consisting of an SC injection of an NSAID or control solution (day 0), followed by oral administration of an NSAID or inert substance for 4 days (days 1 through 4). Treatment regimens included carprofen (4 mg/kg) followed by inert substance; saline (0.9% NaCl) solution followed by deracoxib (4 mg/kg); carprofen (4 mg/kg) followed by carprofen (4 mg/kg); and carprofen (4 mg/kg) followed by deracoxib (4 mg/kg). Hematologic, serum biochemical, and fecal evaluations were conducted weekly, and clinical scores were obtained daily. Endoscopy of the GIT was performed before and on days 1, 2, and 5 for each treatment. Lesions were scored by use of a 6-point scale. No significant differences existed for clinical data, clinicopathologic data, or lesion scores in the esophagus, cardia, or duodenum. For the gastric fundus, antrum, and lesser curvature, an effect of time was observed for all treatments, with lesions worsening from before to day 2 of treatments but improving by day 5. Sequential administration of NSAIDs in this experiment did not result in clinically important gastroduodenal ulcers. A larger study to investigate the effect of sequential administration of NSAIDs for longer durations and in dogs with signs of acute and chronic pain is essential to substantiate these findings.

  2. Semi-Automated Hydrophobic Interaction Chromatography Column Scouting Used in the Two-Step Purification of Recombinant Green Fluorescent Protein

    PubMed Central

    Murphy, Patrick J. M.

    2014-01-01

    Background Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Methods and Results Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conclusions Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in development other of HIC-compatible protein purification schemes. PMID:25254496

  3. Atomic Force Microscope Mediated Chromatography

    NASA Technical Reports Server (NTRS)

    Anderson, Mark S.

    2013-01-01

    The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a sliding plate system, consisting of two flat surfaces, one of which has a recessed channel. A fluid flow is produced by axially sliding one plate past another, where the fluid has mechanical shear forces imposed at each point along the channel length. The shear-induced flow rates are very reproducible, and do not have pressure or voltage gradient limitations. SDC opens up a new range of enhanced separation kinetics by permitting the sample confinement with submicron dimensions. Small, highly confined liquid is advantageous for chromatographic separation because the separation rate is known to scale according to the square of the confined sample diameter. In addition, because shear-driven flows are not limited by fluid velocity, shear-driven liquid chromatography may provide up to 100,000 plate efficiency.

  4. Direct large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry determination of artificial sweeteners sucralose and acesulfame in well water.

    PubMed

    Wu, Minghuo; Qian, Yichao; Boyd, Jessica M; Hrudey, Steve E; Le, X Chris; Li, Xing-Fang

    2014-09-12

    Acesulfame (ACE) and sucralose (SUC) have become recognized as ideal domestic wastewater contamination indicators. Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) analysis is commonly used; however, the sensitivity of SUC is more than two orders of magnitude lower than that of ACE, limiting the routine monitoring of SUC. To address this issue, we examined the ESI behavior of both ACE and SUC under various conditions. ACE is ionic in aqueous solution and efficiently produces simple [M-H](-) ions, but SUC produces multiple adduct ions, limiting its sensitivity. The formic acid (FA) adducts of SUC [M+HCOO](-) are sensitively and reproducibly generated under the LC-MS conditions. When [M+HCOO](-) is used as the precursor ion for SUC detection, the sensitivity increases approximately 20-fold compared to when [M-H](-) is the precursor ion. To further improve the limit of detection (LOD), we integrated the large volume injection approach (500μL injection) with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), which reduced the method detection limit (MDL) to 0.2ng/L for ACE and 5ng/L for SUC. To demonstrate the applicability of this method, we analyzed 100 well water samples collected in Alberta. ACE was detected in 24 wells at concentrations of 1-1534ng/L and SUC in 8 wells at concentrations of 65-541ng/L. These results suggest that wastewater is the most likely source of ACE and SUC impacts in these wells, suggesting the need for monitoring the quality of domestic well water. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Method development and application of offline two-dimensional liquid chromatography/quadrupole time-of-flight mass spectrometry-fast data directed analysis for comprehensive characterization of the saponins from Xueshuantong Injection.

    PubMed

    Yang, Wenzhi; Zhang, Jingxian; Yao, Changliang; Qiu, Shi; Chen, Ming; Pan, Huiqin; Shi, Xiaojian; Wu, Wanying; Guo, Dean

    2016-09-05

    Xueshuantong Injection (XSTI), derived from Notoginseng total saponins, is a popular traditional Chinese medicine injection for the treatment of thrombus-resultant diseases. Current knowledge on its therapeutic basis is limited to five major saponins, whereas those minor ones are rarely investigated. We herein develop an offline two-dimensional liquid chromatography/quadrupole time-of-flight mass spectrometry-fast data directed analysis (offline 2D LC/QTOF-Fast DDA) approach to systematically characterize the saponins contained in XSTI. Key parameters affecting chromatographic separation in 2D LC (including stationary phase, mobile phase, column temperature, and gradient elution program) and the detection by QTOF MS (involving spray voltage, cone voltage, and ramp collision energy) were optimized in sequence. The configured offline 2D LC system showed an orthogonality of 0.84 and a theoretical peak capacity of 8976. Total saponins in XSTI were fractionated into eleven samples by the first-dimensional hydrophilic interaction chromatography, which were further analyzed by reversed-phase UHPLC/QTOF-Fast DDA in negative ion mode. The fragmentation features evidenced from 36 saponin reference standards, high-accuracy MS and Fast-DDA-MS(2) data, elemental composition (C<80, H<120, O<50), double-bond equivalent (DBE 5-15), and searching an in-house library of Panax notoginseng, were simultaneously utilized for structural elucidation. Ultimately, 148 saponins were separated and characterized, and 80 have not been isolated from P. notoginseng. An in-depth depiction of the chemical composition of XSTI was achieved. The results obtained would benefit better understanding of the therapeutic basis and significant promotion on the quality standard of XSTI as well as other homologous products. Copyright © 2016. Published by Elsevier B.V.

  6. New drostanolone metabolites in human urine by liquid chromatography time-of-flight tandem mass spectrometry and their application for doping control.

    PubMed

    Liu, Yang; Lu, Jianghai; Yang, Sheng; Zhang, Qingying; Xu, Youxuan

    2016-04-01

    Drostanolone is one of the most frequently detected anabolic androgenic steroids in doping control analysis. Here, we studied drostanolone urinary metabolic profiles using liquid chromatography quadruple time of flight mass spectrometry (LC-QTOF-MS) in full scan and targeted MS/MS modes with accurate mass measurement. The drug was administered to one healthy male volunteer and liquid-liquid extraction along with direct-injection were used to analyze urine samples. Chromatographic peaks for potential metabolites were identified with the theoretical [M-H](-) as a target ion in a full scan experiment and actual deprotonated ions were analyzed in targeted MS/MS mode. Eleven metabolites including five new sulfates, five glucuronide conjugates, and one free metabolite were confirmed for drostanolone. Due to the absence of useful fragment ions to illustrate the steroid ring structure of drostanolone phase II metabolites, gas chromatography mass spectrometry (GC-MS) was used to obtain structural details of the trimethylsilylated phase I metabolite released after enzymatic hydrolysis and a potential structure was proposed using a combined MS approach. Metabolite detection times were recorded and S4 (2α-methyl-5α-androstan-17-one-6β-ol-3α-sulfate) and G1 (2α-methyl-5α-androstan-17-one-3α-glucuronide) were thought to be new potential biomarkers for drostanolone misuse which can be detected up to 24days by liquid-liquid extraction and 7days by direct-injection analysis after intramuscular injection. S4 and G1 were also detected in two drostanolone-positive routine urine samples. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Brain serotonin content - Increase following ingestion of carbohydrate diet.

    NASA Technical Reports Server (NTRS)

    Fernstrom, J. D.; Wurtman, R. J.

    1971-01-01

    In the rat, the injection of insulin or the consumption of carbohydrate causes sequential increases in the concentrations of tryptophan in the plasma and the brain and of serotonin in the brain. Serotonin-containing neurons may thus participate in systems whereby the rat brain integrates information about the metabolic state in its relation to control of homeostasis and behavior.

  8. Argentation chromatography coupled to ultrahigh-resolution mass spectrometry for the separation of a heavy crude oil.

    PubMed

    Molnárné Guricza, Lilla; Schrader, Wolfgang

    2017-02-10

    Simplification of highly complex mixtures such as crude oil by using chromatographic methods makes it possible to get more detailed information about the composition of the analyte. Separation by argentation chromatography can be achieved based on the interaction of different strength between the silver ions (Ag + ) immobilized through a spacer on the silica gel surface and the π-bonds of the analytes. Heavy crude oils contain compounds with a high number of heteroatoms (N, O, S) and a high degree of unsaturation thus making them the perfect analyte for argentation chromatography. The direct coupling of argentation chromatography and ultrahigh-resolution mass spectrometry allows to continuously tracking the separation of the many different compounds by retention time and allows sensitive detection on a molecular level. Direct injection of a heavy crude oil into a ultrahigh-resolution mass spectrometer showed components with DBE of up to 25, whereas analytes with DBE of up to 35 could be detected only after separation with argentation chromatography. The reduced complexity achieved by the separation helps increasing the information depth. Copyright © 2016. Published by Elsevier B.V.

  9. Simultaneous concentration and purification through gradient deformation chromatography

    NASA Technical Reports Server (NTRS)

    Velayudhan, A.; Hendrickson, R. L.; Ladisch, M. R.; Mitchell, C. A. (Principal Investigator)

    1995-01-01

    Mobile-phase additives, commonly used to modulate absorbate retention in gradient elution chromatography, are usually assumed to be either linearly retained or unretained. Previous theoretical work from our laboratory has shown that these modulators, such as salts in ion-exchange and hydrophobic interaction chromatography and organic modifiers in reversed-phase chromatography, can absorb nonlinearly, giving rise to gradient deformation. Consequently, adsorbate peaks that elute in the vicinity of the head of the deformed gradient may exhibit unusual shapes, form shoulders, and/or be concentrated. These effects for a reversed-phase sorbent with aqueous acetonitrile (ACN) as the modulator are verified experimentally. Gradient deformation is demonstrated experimentally and agrees with simulations based on ACN isotherm parameters that are independently determined from batch equilibrium studies using the layer model. Unusual absorbate peak shapes were found experimentally for single-component injections of phenylalanine, similar to those calculated by the simulations. A binary mixture of tryptophan and phenylalanine is used to demonstrate simultaneous concentration and separation, again in agreement with simulations. The possibility of gradient deformation in ion-exchange and hydrophobic interaction chromatography is discussed.

  10. Instrument platforms for nano liquid chromatography.

    PubMed

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-11-20

    The history of liquid chromatography started more than a century ago and miniaturization and automation are two leading trends in this field. Nanocolumn liquid chromatography (nano LC) and largely synonymous capillary liquid chromatography (capillary LC) are the most recent results of this process where miniaturization of column dimensions and sorbent particle size play crucial role. Very interesting results achieved in the research of extremely miniaturized LC columns at the end of the last century lacked distinctive raison d'être and only advances in mass spectrometry brought a real breakthrough. Configuration of nano LC-electrospray ionization mass spectrometry (LC-ESI-MS) has become a basic tool in bioanalytical chemistry, especially in proteomics. This review discusses and summarizes past and current trends in the realization of nano liquid chromatography (nano LC) platforms. Special attention is given to the mobile phase delivery under nanoflow rates (isocratic, gradient) and sample injection to the nanocolumn. Available detection techniques applied in nano LC separations are also briefly discussed. We followed up the key themes from the original scientific reports over gradual improvements up to the contemporary commercial solutions. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Sequential injection ionic liquid dispersive liquid-liquid microextraction for thallium preconcentration and determination with flame atomic absorption spectrometry.

    PubMed

    Anthemidis, Aristidis N; Ioannou, Kallirroy-Ioanna G

    2012-08-01

    A novel, automatic on-line sequential injection dispersive liquid-liquid microextraction (SI-DLLME) method, based on 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim][PF(6)]) ionic liquid as an extractant solvent was developed and demonstrated for trace thallium determination by flame atomic absorption spectrometry. The ionic liquid was on-line fully dispersed into the aqueous solution in a continuous flow format while the TlBr(4)(-) complex was easily migrated into the fine droplets of the extractant due to the huge contact area of them with the aqueous phase. Furthermore, the extractant was simply retained onto the surface of polyurethane foam packed into a microcolumn. No specific conditions like low temperature are required for extractant isolation. All analytical parameters of the proposed method were investigated and optimized. For 15 mL of sample solution, an enhancement factor of 290, a detection limit of 0.86 μg L(-1) and a precision (RSD) of 2.7% at 20.0 μg L(-1) Tl(I) concentration level, was obtained. The developed method was evaluated by analyzing certified reference materials while good recoveries from environmental and biological samples proved that present method was competitive in practical applications.

  12. Sequential injection redox or acid-base titration for determination of ascorbic acid or acetic acid.

    PubMed

    Lenghor, Narong; Jakmunee, Jaroon; Vilen, Michael; Sara, Rolf; Christian, Gary D; Grudpan, Kate

    2002-12-06

    Two sequential injection titration systems with spectrophotometric detection have been developed. The first system for determination of ascorbic acid was based on redox reaction between ascorbic acid and permanganate in an acidic medium and lead to a decrease in color intensity of permanganate, monitored at 525 nm. A linear dependence of peak area obtained with ascorbic acid concentration up to 1200 mg l(-1) was achieved. The relative standard deviation for 11 replicate determinations of 400 mg l(-1) ascorbic acid was 2.9%. The second system, for acetic acid determination, was based on acid-base titration of acetic acid with sodium hydroxide using phenolphthalein as an indicator. The decrease in color intensity of the indicator was proportional to the acid content. A linear calibration graph in the range of 2-8% w v(-1) of acetic acid with a relative standard deviation of 4.8% (5.0% w v(-1) acetic acid, n=11) was obtained. Sample throughputs of 60 h(-1) were achieved for both systems. The systems were successfully applied for the assays of ascorbic acid in vitamin C tablets and acetic acid content in vinegars, respectively.

  13. Iodine speciation in coastal and inland bathing waters and seaweeds extracts using a sequential injection standard addition flow-batch method.

    PubMed

    Santos, Inês C; Mesquita, Raquel B R; Bordalo, Adriano A; Rangel, António O S S

    2015-02-01

    The present work describes the development of a sequential injection standard addition method for iodine speciation in bathing waters and seaweeds extracts without prior sample treatment. Iodine speciation was obtained by assessing the iodide and iodate content, the two inorganic forms of iodine in waters. For the determination of iodide, an iodide ion selective electrode (ISE) was used. The indirect determination of iodate was based on the spectrophotometric determination of nitrite (Griess reaction). For the iodate measurement, a mixing chamber was employed (flow batch approach) to explore the inherent efficient mixing, essential for the indirect determination of iodate. The application of the standard addition method enabled detection limits of 0.14 µM for iodide and 0.02 µM for iodate, together with the direct introduction of the target water samples, coastal and inland bathing waters. The results obtained were in agreement with those obtained by ICP-MS and a colorimetric reference procedure. Recovery tests also confirmed the accuracy of the developed method which was effectively applied to bathing waters and seaweed extracts. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Marker retention in the cochlea following injections through the round window membrane

    PubMed Central

    Salt, Alec N.; Sirjani, Davud B.; Hartsock, Jared J.; Gill, Ruth M.; Plontke, Stefan K.

    2007-01-01

    Local delivery of drugs to the inner ear is increasingly being used in both clinical and experimental studies. Although direct injection of drugs into perilymph appears to be the most promising way of administering drugs quantitatively, no studies have yet demonstrated the pharmacokinetics in perilymph following direct injections. In this study, we have investigated the retention of substance in perilymph following a single injection into the basal turn of scala tympani (ST). The substance injected was a marker, trimethylphenylammonium (TMPA) that can be detected in low concentrations with ion-selective microelectrodes. Perilymph pharmacokinetics of TMPA was assessed using sequential apical sampling to obtain perilymph for analysis. The amount of TMPA retained in perilymph was compared for different injection and sampling protocols. TMPA concentrations measured in fluid samples were close to those predicted by simulations when the injection pipette was sealed into the bony wall of ST but were systematically lower when the injection pipette was inserted through the round window membrane (RWM). In the latter condition it was estimated that over 60% of the injected TMPA was lost due to leakage of perilymph around the injection pipette at a rate estimated to be 0.09 μL/min. The effects of leakage during and after injections through the RWM were dramatically reduced when the round window niche was filled with 1% sodium hyaluronate gel before penetrating the RWM with the injection pipette. The findings demonstrate that in order to perform quantitative drug injections into perilymph, even small rates of fluid leakage at the injection site must be controlled. PMID:17662546

  15. Determination of low molecular weight alcohols including fusel oil in various samples by diethyl ether extraction and capillary gas chromatography.

    PubMed

    Woo, Kang-Lyung

    2005-01-01

    Low molecular weight alcohols including fusel oil were determined using diethyl ether extraction and capillary gas chromatography. Twelve kinds of alcohols were successfully resolved on the HP-FFAP (polyethylene glycol) capillary column. The diethyl ether extraction method was very useful for the analysis of alcohols in alcoholic beverages and biological samples with excellent cleanliness of the resulting chromatograms and high sensitivity compared to the direct injection method. Calibration graphs for all standard alcohols showed good linearity in the concentration range used, 0.001-2% (w/v) for all alcohols. Salting out effects were significant (p < 0.01) for the low molecular weight alcohols methanol, isopropanol, propanol, 2-butanol, n-butanol and ethanol, but not for the relatively high molecular weight alcohols amyl alcohol, isoamyl alcohol, and heptanol. The coefficients of variation of the relative molar responses were less than 5% for all of the alcohols. The limits of detection and quantitation were 1-5 and 10-60 microg/L for the diethyl ether extraction method, and 10-50 and 100-350 microg/L for the direct injection method, respectively. The retention times and relative retention times of standard alcohols were significantly shifted in the direct injection method when the injection volumes were changed, even with the same analysis conditions, but they were not influenced in the diethyl ether extraction method. The recoveries by the diethyl ether extraction method were greater than 95% for all samples and greater than 97% for biological samples.

  16. Determination of Total Petroleum Hydrocarbons in Australian Groundwater Through the Improvised Gas Chromatography-Flame Ionization Detection Technique.

    PubMed

    Faustorilla, Maria Vilma; Chen, Zuliang; Dharmarajan, Rajarathnam; Naidu, Ravendra

    2017-09-01

    Assessment of total petroleum hydrocarbons (TPHs) from contaminated sites demands routine and reliable measurement at trace levels. However, the detection limits of these methods need to be improved. This study developed the programmable temperature vaporization-large volume injection (PTV-LVI) method to quantify TPHs through gas chromatography-flame ionization detection. This configuration enhances the method sensitivity for trace level detections through large volume injections and pre-concentration of analytes along the injection liner. The method was evaluated for the three commonly observed hydrocarbon fractions: C10-C14, C15-C28 and C29-C36. In comparison with conventional injection methods (splitless and pulsed splitless), PTV-LVI showed R2 values > 0.999 with enhanced limits of detection and limits of quantification values. The method was applied to real samples for routine environmental monitoring of TPHs in an Australian contaminated site characterized by refueling station. Analysis of groundwater samples in the area showed a wide range of TPH concentrations as follows: 66-1,546,000 (C10-C14), 216-22,762 (C15-C28) and 105-2,103 (C29-C36) μg/L. This method has detected trace levels, thereby measuring a wider concentration range of TPHs. These more accurate measurements can lead to the appropriate application of risk assessments and remediation techniques. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Isolation and structural determination of squalene synthase inhibitor from Prunus mume fruit.

    PubMed

    Choi, Sung-Won; Hur, Nam-Yoon; Ahn, Soon-Cheol; Kim, Dong-Seob; Lee, Jae-Kwon; Kim, Dae-Ok; Park, Seung-Kook; Kim, Byung-Yong; Baik, Moo-Yeol

    2007-12-01

    Squalene synthase plays an important role in the cholesterol biosynthetic pathway. Inhibiting this enzyme in hypercholesterolemia can lower not only plasma cholesterol but also plasma triglyceride levels. A squalene synthase inhibitor was screened from Prunus mume fruit, and then purified via sequential processes of ethanol extraction, HP-20 column chromatography, ethyl acetate extraction, silica gel column chromatography, and crystallization. The squalene synthase inhibitor was identified as chlorogenic acid with a molecular mass of 354 Da and a molecular formula of C16H18O9 based on UV spectrophotometry, 1H and 13C NMRs, and mass spectrometry. Chlorogenic acid inhibited the squalene synthase of pig liver with an IC50 level of 100 nM. Since chlorogenic acid was an effective inhibitor against the squalene synthase of an animal source, it may be a potential therapeutic agent for hypercholesterolemia.

  18. Purification and Characterization of a Fibrinolytic Enzyme from Bacillus pumilus 2.g Isolated from Gembus, an Indonesian Fermented Food

    PubMed Central

    Afifah, Diana Nur; Sulchan, Muhammad; Syah, Dahrul; Yanti; Suhartono, Maggy Thenawidjaja; Kim, Jeong Hwan

    2014-01-01

    Bacillus pumilus 2.g isolated from gembus, an Indonesian fermented soybean cake, secretes several proteases that have strong fibrinolytic activities. A fibrinolytic enzyme with an apparent molecular weight of 20 kDa was purified from the culture supernatant of B. pumilus 2.g by sequential application of ammonium sulfate precipitation, ion-exchange chromatography, and hydrophobic chromatography. The partially purified enzyme was stable between pH 5 and pH 9 and temperature of less than 60°C. Fibrinolytic activity was increased by 5 mM MgCl2 and 5 mM CaCl2 but inhibited by 1 mM phenylmethylsulfonyl fluoride (PMSF), 1 mM sodium dodecyl sulfate (SDS), and 1 mM ethylenediaminetetraacetic acid (EDTA). The partially purified enzyme quickly degraded the α and β chains of fibrinogen but was unable to degrade the γ chain. PMID:25320719

  19. Optimization of the separation of lysergic acid diethylamide in urine by a sweeping technique using micellar electrokinetic chromatography.

    PubMed

    Fang, Ching; Liu, Ju-Tsung; Lin, Cheng-Huang

    2002-07-25

    The separation and on-line concentrations of lysergic acid diethylamide (LSD), iso-lysergic acid diethylamide (iso-LSD) and lysergic acid N,N-methylpropylamide (LAMPA) in human urine were investigated by capillary electrophoresis-fluorescence spectroscopy using sodium dodecyl sulfate (SDS) as an anionic surfactant. A number of parameters such as buffer pH, SDS concentration, Brij-30 concentration and the content of organic solvent used in separation, were optimized. The techniques of sweeping-micellar electrokinetic chromatography (sweeping-MEKC) and cation-selective exhaustive injection-sweep-micellar electrokinetic chromatography (CSEI-sweep-MEKC) were used for determining on-line concentrations. The advantages and disadvantages of this procedure with respect to sensitivity, precision and simplicity are discussed and compared. Copyright 2002 Elsevier Science BV.

  20. Supercritical-fluid extraction and chromatography-mass spectrometry for analysis of mycotoxins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, R.D.; Udseth, H.R.

    1982-07-01

    The use of direct supercritical-fluid injection-mass spectrometry for the rapid analysis of mycotoxins of the tricothecene group is demonstrated. A solution containing diacetoxyscirpenol or T-2 toxin is injected into a fluid consisting primarily of pentane or carbon dioxide and is rapidly brought to supercritical conditions. Direct injection of the fluid stream into a chemical ionization source allows thermally labile compounds to be analyzed. Under these conditions trichothecene mass spectra showing significant (M + 1)/sup +/ ions and distinctive fragmentation patterns are obtained. Detection limits are in the subnanogram range. Direct analysis from complex substrates using selective supercritical-fluid extraction is proposed.more » 4 figures.« less

  1. Combined treatment in punctate inner choroidopathy

    PubMed Central

    Terelak-Borys, Barbara; Zagajewska, Katarzyna; Jankowska-Lech, Irmina; Tesla, Piotr; Grabska-Liberek, Iwona

    2016-01-01

    Purpose The purpose of this study was to describe a combination treatment for choroidal neovascular (CNV) membrane, secondary to punctate inner choroidopathy (PIC). Patient and methods A 44-year-old female patient was diagnosed with PIC complicated by the development of recurrent juxtafoveal neovascular membrane. The treatment included a sequence of monotherapy regimens: systemic steroid therapy, photodynamic therapy, and intravitreal injections of vascular endothelial growth factor (VEGF) inhibitor (anti-VEGF). Owing to the CNV membrane resistance to various types of monotherapy, a combination treatment consisting of local injections of steroid underneath the Tenon’s capsule and intravitreal anti-VEGF injections was used. Results Systemic steroid therapy resulted in rapid local improvement with a very short remission period. No positive effects of photodynamic therapy were observed. Sequential anti-VEGF injections led to remission periods of several months. Permanent regression of CNV membrane was achieved following combined local application of steroid and intravitreal anti-VEGF injections. Conclusion A combination treatment including steroid and anti-VEGF medication characterized by anti-inflammatory and antiangiogenic effects may be a very beneficial option for the treatment of recurrent CNV membrane as a complication of PIC. PMID:27729795

  2. HIGH-SPEED GC/MS FOR AIR ANALYSIS

    EPA Science Inventory

    High speed or fast gas chromatography (FGC) consists of narrow bandwidth injection into a high-speed carrier gas stream passing through a short column leading to a fast detector. Many attempts have been made to demonstrate FGC, but until recently no practical method for routin...

  3. Issues surrounding lethal injection as a means of capital punishment.

    PubMed

    Romanelli, Frank; Whisman, Tyler; Fink, Joseph L

    2008-12-01

    Lethal injection as a method of state-sanctioned capital punishment was initially proposed in the United States in 1977 and used for the first time in 1982. Most lethal injection protocols use a sequential drug combination of sodium thiopental, pancuronium bromide, and potassium chloride. Lethal injection was originally introduced as a more humane form of execution compared with existing mechanical methods such as electrocution, toxic gassing, hanging, or firing squad. Lethal injection has not, however, been without controversy. Several states are considering whether lethal injection meets constitutional scrutiny forbidding cruel and unusual punishment. Recently in the case of Ralph Baze and Thomas C. Bowling, Petitioners, v John D. Rees, Commissioner, Kentucky Department of Corrections et al, the United States Supreme Court upheld the constitutionality of the lethal injection protocol as carried out in the Commonwealth of Kentucky. Most of the debate has surrounded the dosing and procedures used in lethal injection and whether the drug combinations and measures for administering the drugs truly produce a timely, pain-free, and fail-safe death. Many have also raised issues regarding the "medicalization" of execution and the ethics of health care professionals' participation in any part of the lethal injection process. As a result of all these issues, the future of lethal injection as a means of execution in the United States is under significant scrutiny. Outcomes of ongoing legislative and judicial reviews might result in cessation of lethal injection in totality or in alterations involving specific drug combinations or administration procedures.

  4. Identification and characterization of gadolinium(III) complexes in biological tissue extracts.

    PubMed

    Kahakachchi, Chethaka L; Moore, Dennis A

    2010-07-01

    The gadolinium species present in a rat kidney following intravenous administration of a gadolinium-based magnetic resonance contrast agent (Optimark™, Gadoversetamide injection) to a rat was examined in the present study. The major gadolinium species in the supernatant of the rat kidney tissue extracts was determined by reversed-phase liquid chromatography with online inductively coupled plasma optical emission spectrometry (HPLC-ICP-OES). The identity of the compound was established by liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) detection. The principal gadolinium(III) complex in a rat kidney tissue extract was identified as Gd-DTPA-BMEA 24 Hrs and 7 days after a single intravenous injection of Optimark™ (gadoversetamide; Gd-DTPA-BMEA) at a dose of 5 mmol Gd/kg body weight. The study demonstrated for the first time the feasibility of the use of two complementary techniques, HPLC-ICP-OES and HPLC-ESI-MS to study the in vivo behavior of gadolinium-based magnetic resonance contrast media.

  5. An analog neural hardware implementation using charge-injection multipliers and neutron-specific gain control.

    PubMed

    Massengill, L W; Mundie, D B

    1992-01-01

    A neural network IC based on a dynamic charge injection is described. The hardware design is space and power efficient, and achieves massive parallelism of analog inner products via charge-based multipliers and spatially distributed summing buses. Basic synaptic cells are constructed of exponential pulse-decay modulation (EPDM) dynamic injection multipliers operating sequentially on propagating signal vectors and locally stored analog weights. Individually adjustable gain controls on each neutron reduce the effects of limited weight dynamic range. A hardware simulator/trainer has been developed which incorporates the physical (nonideal) characteristics of actual circuit components into the training process, thus absorbing nonlinearities and parametric deviations into the macroscopic performance of the network. Results show that charge-based techniques may achieve a high degree of neural density and throughput using standard CMOS processes.

  6. [Study for the revision of analytical method for tris (2,3-dibromopropyl) phosphate with restriction in textiles].

    PubMed

    Mimura, Mayumi; Nakashima, Harunobu; Yoshida, Jin; Yoshida, Toshiaki; Kawakami, Tsuyoshi; Isama, Kazuo

    2014-01-01

    The official analytical method for tris(2,3-dibromopropyl)phosphate (TDBPP), which is banned from use in textile products by the "Act on Control of Household Products Containing Harmful Substances", requires revision. This study examined an analytical method for TDBPP by GC/MS using a capillary column. Thermal decomposition of TDBPP was observed by GC/MS measurement using capillary column, unlike in the case of gas chromatography/flame photometric detector (GC/FPD) measurement based on a direct injection method using a capillary megabore column. A quadratic curve, Y=2572X(1.416), was obtained for the calibration curve of GC/FPD in the concentration range 2.0-100 μg/mL. The detection limit was 1.0 μg/mL under S/N=3. The reproducibility for repetitive injections was satisfactory. A pretreatment method was established using methanol extraction, followed by liquid-liquid partition and purification with a florisil cartridge column. The recovery rate of this method was ~100%. TDBPP was not detected in any of the five commercial products that this study analyzed. To understand the cause of TDBPP decomposition during GC/MS (electron ionization; EI) measurement using capillary column, GC/MS (chemical ionization; CI), GC/FPD, and gas chromatography/flame ionization detector (GC/FID) measurements were conducted. It was suggested that TDBPP might thermally decompose both during GC injection, especially through a splitless injection method, and in the column or ion sources. To attempt GC/MS measurement, an injection part comprising quartz liner was used and the column length was halved (15 m); thus, only one peak could be obtained.

  7. Ultra-performance liquid chromatography/tandem mass spectrometric quantification of structurally diverse drug mixtures using an ESI-APCI multimode ionization source.

    PubMed

    Yu, Kate; Di, Li; Kerns, Edward; Li, Susan Q; Alden, Peter; Plumb, Robert S

    2007-01-01

    We report in this paper an ultra-performance liquid chromatography/tandem mass spectrometric (UPLC(R)/MS/MS) method utilizing an ESI-APCI multimode ionization source to quantify structurally diverse analytes. Eight commercial drugs were used as test compounds. Each LC injection was completed in 1 min using a UPLC system coupled with MS/MS multiple reaction monitoring (MRM) detection. Results from three separate sets of experiments are reported. In the first set of experiments, the eight test compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes (ESI+, ESI-, APCI-, and APCI+) during an LC run. Approximately 8-10 data points were collected across each LC peak. This was insufficient for a quantitative analysis. In the second set of experiments, four compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes during an LC run. Approximately 15 data points were obtained for each LC peak. Quantification results were obtained with a limit of detection (LOD) as low as 0.01 ng/mL. For the third set of experiments, the eight test compounds were analyzed as a batch. During each LC injection, a single compound was analyzed. The mass spectrometer was detecting at a particular ionization mode during each LC injection. More than 20 data points were obtained for each LC peak. Quantification results were also obtained. This single-compound analytical method was applied to a microsomal stability test. Compared with a typical HPLC method currently used for the microsomal stability test, the injection-to-injection cycle time was reduced to 1.5 min (UPLC method) from 3.5 min (HPLC method). The microsome stability results were comparable with those obtained by traditional HPLC/MS/MS.

  8. A new rat model of portal hypertension induced by intraportal injection of microspheres

    PubMed Central

    Li, Xiang-Nong; Benjamin, IS; Alexander, B

    1998-01-01

    AIM: To produce a new rat model of portal hypertension by intraportal injection of microspheres. METHODS: Measured aliquots of single or different-sized microspheres (15, 40, 80μm) were injected into the portal vein to block intrahepatic portal radicals. The resultant changes in arterial,portal,hepatic venous and splenic pulp pressures were monitored. The liver and lungs were excised for histological examination. RESULTS: Portal venous pressure was elevated from basal value of 0.89-1.02 kPa to a steady-state of 1.98-3.19 kPa following the sequential injections of single- or different-sized microspheres, with a markedly lowered mean arterial pressure. However, a small-dose injection of 80 μm microspheres (1.8 × 105) produced a steady-state portal venous pressure of 2.53 × 0.17 kPa, and all rats showed normal arterial pressures. In addition, numerous microspheres were found in the lungs in all experimental groups. CONCLUSION: Portal hypertension can be reproduced in rats by intraportal injection of microspheres at a small dose of 80 μm (1.8 × 105). Intrahepatic portal-systemic shunts probably exist in the normal rat liver. PMID:11819236

  9. Miniaturised electrically actuated high pressure injection valve for portable capillary liquid chromatography.

    PubMed

    Li, Yan; Pace, Kirsten; Nesterenko, Pavel N; Paull, Brett; Stanley, Roger; Macka, Mirek

    2018-04-01

    A miniaturised high pressure 6-port injection valve has been designed and evaluated for its performance in order to facilitate the development of portable capillary high performance liquid chromatography (HPLC). The electrically actuated valve features a very small size (65 × 19 × 19mm) and light weight (33g), and therefore can be easily integrated in a miniaturised modular capillary LC system suited for portable field analysis. The internal volume of the injection valve was determined as 98 nL. The novel conical shape of the stator and rotor and the spring-loaded rotor performed well up to 32MPa (4641psi), the maximum operating pressure investigated. Suitability for application was demonstrated using a miniaturised capillary LC system applied to the chromatographic separation of a mixture of biogenic amines and common cations. The RSD (relative standard deviation) values of retention times and peak areas of 6 successive runs were 0.5-0.7% and 1.8-2.8% for the separation of biogenic amines, respectively, and 0.1-0.2% and 2.1-3.0% for the separation of cations, respectively. This performance was comparable with bench-top HPLC systems thus demonstrating the applicability of the valve for use in portable and miniaturised capillary HPLC systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Rapid determination of piracetam in human plasma and cerebrospinal fluid by micellar electrokinetic chromatography with sample direct injection.

    PubMed

    Yeh, Hsin-Hua; Yang, Yuan-Han; Ko, Ju-Yun; Chen, Su-Hwei

    2006-07-07

    A simple micellar electrokinetic chromatography (MEKC) method with UV detection at 200 nm for analysis of piracetam in plasma and in cerebrospinal fluid (CSF) by direct injection without any sample pretreatment is described. The separation of piracetam from biological matrix was performed at 25 degrees C using a background electrolyte consisting of Tris buffer with sodium dodecyl sulfate (SDS) as the electrolyte solution. Several parameters affecting the separation of the drug from biological matrix were studied, including the pH and concentrations of the Tris buffer and SDS. Under optimal MEKC condition, good separation with high efficiency and short analyses time is achieved. Using imidazole as an internal standard (IS), the linear ranges of the method for the determination of piracetam in plasma and in CSF were all between 5 and 500 microg/mL; the detection limit of the drug in plasma and in CSF (signal-to-noise ratio=3; injection 0.5 psi, 5s) was 1.0 microg/mL. The applicability of the proposed method for determination of piracetam in plasma and CSF collected after intravenous administration of 3g piracetam every 6h and oral administration 1.2g every 6h in encephalopathy patients with aphasia was demonstrated.

  11. Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikova, Olga S; Kertesz, Vilmos; Van Berkel, Gary J

    This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of thismore » coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.« less

  12. Identification and differentiation of methcathinone analogs by gas chromatography-mass spectrometry.

    PubMed

    Tsujikawa, Kenji; Mikuma, Toshiyasu; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki

    2013-08-01

    To overcome a number of challenges involved in analyzing methcathinone (MC) analogues, we performed gas chromatography-mass spectrometry (GC-MS) analysis, including sample preparation, of nine MC analogues - 4-methylmethcathinone, three positional isomers of fluoromethcathinones, 4-methoxymethcathinone, N-ethylcathinone, N,N-dimethylcathinone, buphedrone, and pentedrone. The MC analogues underwent dehydrogenation when the free bases were analyzed using splitless injection. Most of this thermal degradation was prevented using split injection. This indicated that a shorter residence time in the hot injector prevented decomposition. Uniquely, 2-fluoromethcathinone degraded to another product in a process that could not be prevented by the split injection. Replacing the liner with a new, clean one was also effective in preventing thermal degradation. Most of the analytes showed a substantial loss (>30%) when the free base solution in ethyl acetate was evaporated under a nitrogen stream. Adding a small amount of dimethylformamide as a solvent keeper had a noticeable effect, but it did not completely prevent the loss. Three positional isomers of fluoromethcathinones were separated with baseline resolution by heptafluorobutyrylation with a slow column heating rate (8 °C/min) using a non-polar DB-5 ms capillary column. These results will be useful for the forensic analysis of MC analogues in confiscated materials. Copyright © 2012 John Wiley & Sons, Ltd.

  13. Single well tracer method to evaluate enhanced recovery

    DOEpatents

    Sheely, Jr., Clyde Q.; Baldwin, Jr., David E.

    1978-01-01

    Data useful to evaluate the effectiveness of or to design an enhanced recovery process (the recovery process involving mobilizing and moving hydrocarbons through a hydrocarbon-bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well) are obtained by a process which comprises sequentially: determining hydrocarbon saturation in the formation in a volume in the formation near a well bore penetrating the formation, injecting sufficient of the mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore penetrating the formation, and determining by the single well tracer method a hydrocarbon saturation profile in a volume from which hydrocarbons are moved. The single well tracer method employed is disclosed by U.S. Pat. No. 3,623,842. The process is useful to evaluate surfactant floods, water floods, polymer floods, CO.sub.2 floods, caustic floods, micellar floods, and the like in the reservoir in much less time at greatly reduced costs, compared to conventional multi-well pilot test.

  14. Development of an efficient fractionation method for the preparative separation of sesquiterpenoids from Tussilago farfara by counter-current chromatography.

    PubMed

    Song, Kwangho; Lee, Kyoung Jin; Kim, Yeong Shik

    2017-03-17

    A novel application of counter-current chromatography (CCC) to enrich plant extracts using direct and continuous injection (CCC-DCI) was developed to fractionate sesquiterpenoids from the buds of Tussilago farfara L. In this study, an n-hexane-acetonitrile-water (HAcW) solvent system was separately pumped into the CCC column, and an extraction solution (45% acetonitrile) was directly and continuously injected into the CCC column. Since the extraction solution was used as a mobile phase in this method, solvent consumption could be greatly reduced. To enrich the extraction solution (315.9g/5.4L), only 4.2L water, 4.6L acetonitrile, and 1.2L n-hexane were used, including the extraction step. Finally, 6.8g of a sesquiterpenoid-enriched (STE) fraction was obtained from the crude extract (315.9g) of Tussilago farfara (1kg) in a single CCC run with a separation time of 8.5h. The sample injection capacity of CCC-DCI was greater than 300g; this amount of sample could not be handled in conventional CCC or other fractionation methods with the same column volume. Moreover, three major sesquiterpenoids (1: tussilagone, 2: 14-acetoxy-7β-(3'-ethyl cis-crotonoyloxy)-1α-(2'-methylburyryloxy)-notonipetranone, and 3: 7β-(3'-ethyl cis-crotonoyloxy)-1α-(2'-methylburyryloxy)-3, 14-dehydro-Z-notonipetranone) were purified from the STE fraction by CCC, and their chemical structures were elucidated by 1 H NMR and 13 C NMR. A quantification study was conducted, and the contents of compounds 1-3 in the CCC-DCI fraction were higher than those of conventional multi-step fractionations performed in series: solvent partitioning and open column chromatography. Furthermore, the average CCC-DCI recoveries were 96.1% (1), 96.9% (2), and 94.6% (3), whereas the open column chromatography recoveries were 77.7% (1), 66.5% (2), and 58.4% (3). The developed method demonstrates that CCC is a useful technique for enriching target components from natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Qualitative and quantitative analysis of hyaluronan oligosaccharides with high performance thin layer chromatography using reagent-free derivatization on amino-modified silica and electrospray ionization-quadrupole time-of-flight mass spectrometry coupling on normal phase.

    PubMed

    Rothenhöfer, Martin; Scherübl, Rosmarie; Bernhardt, Günther; Heilmann, Jörg; Buschauer, Armin

    2012-07-27

    Purified oligomers of hyalobiuronic acid are indispensable tools to elucidate the physiological and pathophysiological role of hyaluronan degradation by various hyaluronidase isoenzymes. Therefore, we established and validated a novel sensitive, convenient, rapid, and cost-effective high performance thin layer chromatography (HPTLC) method for the qualitative and quantitative analysis of small saturated hyaluronan oligosaccharides consisting of 2-4 hyalobiuronic acid moieties. The use of amino-modified silica as stationary phase allows a simple reagent-free in situ derivatization by heating, resulting in a very low limit of detection (7-19 pmol per band, depending on the analyzed saturated oligosaccharide). By this derivatization procedure for the first time densitometric quantification of the analytes could be performed by HPTLC. The validated method showed a quantification limit of 37-71 pmol per band and was proven to be superior in comparison to conventional detection of hyaluronan oligosaccharides. The analytes were identified by hyphenation of normal phase planar chromatography to mass spectrometry (TLC-MS) using electrospray ionization. As an alternative to sequential techniques such as high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), the validated HPTLC quantification method can easily be automated and is applicable to the analysis of multiple samples in parallel. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Automated solid-phase extraction of phenolic acids using layered double hydroxide-alumina-polymer disks.

    PubMed

    Ghani, Milad; Palomino Cabello, Carlos; Saraji, Mohammad; Manuel Estela, Jose; Cerdà, Víctor; Turnes Palomino, Gemma; Maya, Fernando

    2018-01-26

    The application of layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disks for solid-phase extraction is reported for the first time. Al 2 O 3 is embedded in a polymer matrix followed by an in situ metal-exchange process to obtain a layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disk with excellent flow-through properties. The extraction performance of the prepared disks is evaluated as a proof of concept for the automated extraction using sequential injection analysis of organic acids (p-hydroxybenzoic acid, 3,4-dihydroxybenzoic acid, gallic acid) following an anion-exchange mechanism. After the solid-phase extraction, phenolic acids were quantified by reversed-phase high-performance liquid chromatography with diode-array detection using a core-shell silica-C18 stationary phase and isocratic elution (acetonitrile/0.5% acetic acid in pure water, 5:95, v/v). High sensitivity and reproducibility were obtained with limits of detection in the range of 0.12-0.25 μg/L (sample volume, 4 mL), and relative standard deviations between 2.9 and 3.4% (10 μg/L, n = 6). Enrichment factors of 34-39 were obtained. Layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disks had an average lifetime of 50 extractions. Analyte recoveries ranged from 93 to 96% for grape juice and nonalcoholic beer samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. N-linked glycoprotein analysis using dual-extraction ultrahigh-performance liquid chromatography and electrospray tandem mass spectrometry.

    PubMed

    Siu, S O; Lam, Maggie P Y; Lau, Edward; Yeung, William S B; Cox, David M; Chu, Ivan K

    2010-01-01

    Although reverse-phase liquid chromatography (RP-LC) is a common technique for peptide separation in shotgun proteomics and glycoproteomics, it often provides unsatisfactory results for the analysis of glycopeptides and glycans. This bias against glycopeptides makes it difficult to study glycoproteins. By coupling mass spectrometry (MS) with a combination of RP-LC and normal-phase (NP)-LC as an integrated front-end separation system, we demonstrate that effective identification and characterization of both peptides and glycopeptides mixtures, and their constituent glycan structures, can be achieved from a single sample injection event.

  18. [Simultaneous analysis of aromatic aldehydes and coumarins with high pressure liquid chromatography. Application to wines and brandies stored in oak barrels].

    PubMed

    Salagoity-Auguste, M H; Tricard, C; Sudraud, P

    1987-04-17

    Aromatic aldehydes (vanillin, syringaldehyde, coniferaldehyde and sinapaldehyde) and coumarins (esculetin, umbelliferone, scopoletin and methylumbelliferone) are natural wood compounds. Storage of wines and brandies in oak barrels increases notably aldehydes and coumarins (particularly scopoletin) concentrations. These compounds were separated by high-performance liquid chromatography, on hydrocarbon bonded reversed-phase packings, with a water-acetonitrile elution gradient. They were first extracted from wines and brandies by diethyl ether and then injected on chromatographic column. A double detection was used to determine simultaneously aromatic aldehydes and coumarins by UV absorption and fluorescence respectively.

  19. Residue depletion of tilmicosin in cattle after subcutaneous administration.

    PubMed

    Jiang, Haiyang; Ding, Shuangyang; Li, Jiancheng; An, Dianjin; Li, Cun; Shen, Jianzhong

    2006-07-12

    A study of tissue residue depletion of tilmicosin in cattle was conducted after a single subcutaneous injection at the therapeutic level of 10 mg per kg body weight. Eighteen cross cattle were treated with the tilmicosin oil formulation (30%). Three treated animals (two males and one female) were selected randomly to be scarified at 1, 7, 14, 28, and 35 days withdrawal after injection. Samples of the injection site and of muscle, liver, kidney, and fat were collected. Tilmicosin residue concentrations were determined using a high-performance liquid chromatography (HPLC) method with a UV detector at 290 nm. Using a statistical method recommended by the Committee for Veterinary Medical Products of European Medical Evaluation Agency, the withdrawal time of 34 days was established when all tissue residues except samples in the injection site were below the accepted maximum residue limits.

  20. RAPID DETERMINATION OF ACTINIDES IN URINE BY INDUCTIVELY-COUPLED PLASMA MASS SPECTROMETRY AND ALPHA SPECTROMETRY: A HYBRID APPROACH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.; Jones, V.

    2009-05-27

    A new rapid separation method that allows separation and preconcentration of actinides in urine samples was developed for the measurement of longer lived actinides by inductively coupled plasma mass spectrometry (ICP-MS) and short-lived actinides by alpha spectrometry; a hybrid approach. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration, if required, is performed using a streamlined calcium phosphate precipitation. Similar technology has been applied to separate actinides prior to measurement by alpha spectrometry, but this new method has been developed with elution reagents now compatible with ICP-MS as well. Purified solutions are splitmore » between ICP-MS and alpha spectrometry so that long- and short-lived actinide isotopes can be measured successfully. The method allows for simultaneous extraction of 24 samples (including QC samples) in less than 3 h. Simultaneous sample preparation can offer significant time savings over sequential sample preparation. For example, sequential sample preparation of 24 samples taking just 15 min each requires 6 h to complete. The simplicity and speed of this new method makes it attractive for radiological emergency response. If preconcentration is applied, the method is applicable to larger sample aliquots for occupational exposures as well. The chemical recoveries are typically greater than 90%, in contrast to other reported methods using flow injection separation techniques for urine samples where plutonium yields were 70-80%. This method allows measurement of both long-lived and short-lived actinide isotopes. 239Pu, 242Pu, 237Np, 243Am, 234U, 235U and 238U were measured by ICP-MS, while 236Pu, 238Pu, 239Pu, 241Am, 243Am and 244Cm were measured by alpha spectrometry. The method can also be adapted so that the separation of uranium isotopes for assay is not required, if uranium assay by direct dilution of the urine sample is preferred instead. Multiple vacuum box locations may be set-up to supply several ICP-MS units with purified sample fractions such that a high sample throughput may be achieved, while still allowing for rapid measurement of short-lived actinides by alpha spectrometry.« less

  1. 40 CFR 63.365 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for Volatile Alcohols in Water By Direct Aqueous-Injection Gas Chromatography, (incorporated by... be determined by either: (A) Weighing the ethylene oxide gas cylinder(s) used to charge the... mass of gas charged by the weight percent ethylene oxide present in the gas. (B) Installing calibrated...

  2. A prospective randomized study comparing two commercially available types of human embryo culture media: G1-PLUS™/G2-PLUS™ sequential medium (Vitrolife) and the GL BLAST™ sole medium (Ingamed).

    PubMed

    Ceschin, Ianae I; Ribas, Mariana H; Ceschin, Alvaro P; Nishikawa, Lucileine; Rocha, Claudia C; Pic-Taylor, Aline; Baroneza, José Eduardo

    2016-03-01

    To check the efficacy of two types of commercially available embryo culture medium: G1-PLUS™/G2-PLUS™ sequential (Vitrolife, Gothenburg, Sweden) and GV BLAST™ sole (Ingamed, Maringá, Brazil) with regards to fertilization, cleavage, blastocyst and pregnancy rates. Prospective and randomized study conducted from March to July 2015, using the medical records of 60 patients submitted to Intracytoplasmic Sperm Injection techniques (ICSI). Data regarding the age of patients, together with fertilization, cleavage, blastocyst and pregnancy rates, were collected and compared in relation to the: G1-PLUS™/G2-PLUS™ sequential and GV BLAST™ sole mediums. The data were tabulated and compared using the Pearson's Chi-Square test (95% CI). There was no significant difference when comparing patients divided into higher and lower fertility age. No significant statistical difference was noted between the fertilization rates (P=0.59), cleavage (P=0.91), evolution to blastocyst (P=0.33) and total pregnancy (P=0.83) when comparing the embryos cultured in the different media analysed. We conclude that the G1-PLUS™/G2-PLUS™ sequential and GV BLAST™ sole mediums are equally effective with regards to fertilization, cleavage, blastocyst development and total pregnancy rates.

  3. A novel sequential process for remediating rare-earth wastewater.

    PubMed

    Cui, Mingcan; Jang, Min; Kang, Kyounglim; Kim, Dukmin; Snyder, Shane A; Khim, Jeehyeong

    2016-02-01

    A novel and economic sequential process consisting of precipitation, adsorption, and oxidation was developed to remediate actual rare-earth (RE) wastewater containing various toxic pollutants, including radioactive species. In the precipitation step, porous air stones (PAS) containing waste oyster shell (WOS), PASWOS, was prepared and used to precipitate most heavy metals with >97% removal efficiencies. The SEM-EDS analysis revealed that PAS plays a key role in preventing the surface coating of precipitants on the surface of WOS and in releasing the dissolved species of WOS successively. For the adsorption step, a polyurethane (PU) impregnated by coal mine drainage sludge (CMDS), PUCMDS, was synthesized and applied to deplete fluoride (F), arsenic (As), uranium (U), and thorium (Th) that remained after precipitation. The continuous-mode sequential process using PAS(WOS), PU(CMDS), and ozone (O3) had 99.9-100% removal efficiencies of heavy metals, 99.3-99.9% of F and As, 95.8-99.4% of U and Th, and 92.4% of COD(Cr) for 100 days. The sequential process can treat RE wastewater economically and effectively without stirred-tank reactors, pH controller, continuous injection of chemicals, and significant sludge generation, as well as the quality of the outlet met the EPA recommended limits. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Microbial degradation of alkyl carbazoles in Norman Wells crude oil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fedorak, P.M.; Westlake, D.W.S.

    Norman Wells crude oil was fractionated by sequential alumina and silicic acid column chromatography methods. The resulting nitrogen-rich fraction was analyzed by gas chromatography-mass spectrometry and showed 26 alkyl (C/sub 1/ to C/sub 5/) carbazoles to be the predominant compounds. An oil-degrading mixed bacterial culture was enriched on carbazole to enhance its ability to degrade nitrogen heterocycles. This culture was used to inoculate a series of flasks of mineral medium and Norman Wells crude oil. Residual oil was recovered from these cultures after incubation at 25/sup 0/C for various times. The nitrogen-rich fraction was analyzed by capillary gas chromatography, usingmore » a nitrogen-specific detector. Most of the C/sub 1/-, C/sub 2/-, and C/sub 3/- carbazoles and one of the C/sub 4/-isomers were degraded within 8 days. No further degradation occurred when incubation was extended to 28 days. The general order of susceptibility of the isomers to biodegradation was C/sub 1/ > C/sub 2/ > C/sub 3/ > C/sub 4/. The carbazole-enriched culture was still able to degrade n-alkanes, isoprenoids, aromatic hydrocarbons, and sulfur heterocycles in the crude soil. 26 references.« less

  5. Rapid characterization of the chemical constituents of Cortex Fraxini by homogenate extraction followed by UHPLC coupled with Fourier transform ion cyclotron resonance mass spectrometry and GC-MS.

    PubMed

    Wang, Yinan; Han, Fei; Song, Aihua; Wang, Miao; Zhao, Min; Zhao, Chunjie

    2016-11-01

    Cortex Fraxini is an important traditional Chinese medicine. In this work, a rapid and reliable homogenate extraction method was applied for the fast extraction for Cortex Fraxini, and the method was optimized by response surface methodology. Ultra high performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry and gas chromatography with mass spectrometry were established for the separation and characterization of the constituents of Cortex Fraxini. Liquid chromatography separation was conducted on a C 18 column (150 mm × 2.1 mm, 1.8 μm), and gas chromatography separation was performed on a capillary with a 5% phenyl-methylpolysiloxane stationary phase (30 m × 0.25 mm × 0.25 mm) by injection of silylated samples. According to the results, 33 chemical compounds were characterized by liquid chromatography with mass spectrometry, and 11 chemical compounds were characterized by gas chromatography with mass spectrometry, and coumarins were the major components characterized by both gas chromatography with mass spectrometry and liquid chromatography with mass spectrometry. The proposed homogenate extraction was an efficient and rapid method, and coumarins, phenylethanoid glycosides, iridoid glycosides, phenylpropanoids, and lignans were the main constituents of Cortex Fraxini. This work laid the foundation for further study of Cortex Fraxini and will be helpful for the rapid extraction and characterization of ingredients in other traditional Chinese medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Structural profiling of individual glycosphingolipids in a single thin-layer chromatogram by multiple sequential immunodetection matched with Direct IR-MALDI-o-TOF mass spectrometry.

    PubMed

    Souady, Jamal; Soltwisch, Jens; Dreisewerd, Klaus; Haier, Jörg; Peter-Katalinić, Jasna; Müthing, Johannes

    2009-11-15

    The thin-layer chromatography (TLC) immunoenzyme overlay assay is a widely used tool for antibody-mediated identification of glycosphingolipids (GSLs) in mixtures. However, because the majority of GSLs is left unexamined in a chromatogram of a single assay, we developed a novel method that permits detection of various GSLs by sequential multiple immunostaining combined with individual coloring of GSLs in the same chromatogram. Specific staining was achieved by means of primary anti-GSL antibodies, directed against lactosylceramide, globotriaosylceramide, and globotetraosylceramide, in conjunction with alkaline phosphatase (AP)- or horseradish peroxidase (HRP)-conjugated secondary antibodies together with the appropriate chromogenic substrates. Triple coloring with 5-bromo-4-chloro-3-indolyl phosphate (BCIP)-AP, Fast Red-AP, and 3,3'-diaminobenzidine (DAB)-HRP resulted in blue, red, and black precipitates, respectively, following three sequential immunostaining rounds. Structures of antibody-detected GSLs were determined by direct coupling of TLC with infrared matrix-assisted laser desorption/ionization orthogonal time-of-flight mass spectrometry. This combinatorial technique was used to demonstrate structural GSL profiling of crude lipid extracts from human hepatocellular cancer. This powerful technology allows efficient structural characterization of GSLs in small tissue samples and marks a further step forward in the emerging field of glycosphingolipidomics.

  7. Simultaneous analysis for water- and fat-soluble vitamins by a novel single chromatography technique unifying supercritical fluid chromatography and liquid chromatography.

    PubMed

    Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi

    2014-10-03

    Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system. Copyright © 2014. Published by Elsevier B.V.

  8. Determination of void volume in normal phase liquid chromatography.

    PubMed

    Jiang, Ping; Wu, Di; Lucy, Charles A

    2014-01-10

    Void volume is an important fundamental parameter in chromatography. Little prior discussion has focused on the determination of void volume in normal phase liquid chromatography (NPLC). Various methods to estimate the total void volume are compared: pycnometry; minor disturbance method based on injection of weak solvent; tracer pulse method; hold-up volume based on unretained compounds; and accessible volume based on Martin's rule and its descendants. These are applied to NPLC on silica, RingSep and DNAP columns. Pycnometry provides a theoretically maximum value for the total void volume and should be performed at least once for each new column. However, pycnometry does not reflect the volume of adsorbed strong solvent on the stationary phase, and so only yields an accurate void volume for weaker mobile phase conditions. 1,3,5-Tri-t-butyl benzene (TTBB) results in hold-up volumes that are convenient measures of the void volume for all eluent conditions on charge-transfer columns (RingSep and DNAP), but is weakly retained under weak eluent conditions on silica. Injection of the weak mobile phase component (hexane) may be used to determine void volume, but care must be exercised to select the appropriate disturbance feature. Accessible volumes, that are determined using a homologous series, are always biased low, and are not recommended as a measure of the void volume. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Scale-up protein separation on stainless steel wide bore toroidal columns in the type-J counter-current chromatography.

    PubMed

    Guan, Yue Hugh; Hewitson, Peter; van den Heuvel, Remco N A M; Zhao, Yan; Siebers, Rick P G; Zhuang, Ying-Ping; Sutherland, Ian

    2015-12-11

    Manufacturing high-value added biotech biopharmaceutical products (e.g. therapeutic proteins) requires quick-to-develop, GMP-compliant, easy-to-scale and cost effective preparatory chromatography technologies. In this work, we describe the construction and testing of a set of 5-mm inner diameter stainless steel toroidal columns for use on commercially available preparatory scale synchronous J-type counter-current chromatography (CCC) machinery. We used a 20.2m long column with an aqueous two-phase system containing 14% (w/w) PEG1000 and 14% (w/w) potassium phosphate at pH 7, and tested a sample loading of 5% column volume and a mobile phase flow rate of 20ml/min. We then satisfactorily demonstrated the potential for a weekly protein separation and preparation throughput of ca. 11g based on a normal weekly routine for separating a pair of model proteins by making five stacked injections on a single portion of stationary phase with no stripping. Compared to our previous 1.6mm bore PTFE toroidal column, the present columns enlarged the nominal column processing throughput by nearly 10. For an ideal model protein injection modality, we observed a scaling up factor of at least 21. The 2 scales of protein separation and purification steps were realized on the same commercial CCC device. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. EPA Method 538: Determination of Selected Organic Contaminants in Drinking Water by Direct Aqueous Injection-Liquid Chromatography/Tandem Mass Spectrometry (DAI-LC/MS/MS)

    EPA Pesticide Factsheets

    EPA’s Selected Analytical Methods for Environmental Remediation and Recovery (SAM) lists this method for preparation and analysis of drinking water samples to detect and measure acephate, diisopropyl methylphosphonate (DIMP), methamidophos and thiofanox.

  11. Determination of lysergic acid diethylamide (LSD) in mouse blood by capillary electrophoresis/ fluorescence spectroscopy with sweeping techniques in micellar electrokinetic chromatography.

    PubMed

    Fang, Ching; Liu, Ju-Tsung; Chou, Shiu-Huey; Lin, Cheng-Huang

    2003-03-01

    The separation and on-line concentration of lysergic acid diethylamide (LSD) in mouse blood was achieved by means of capillary electrophoresis/fluorescence spectroscopy using sodium dodecyl sulfate (SDS) as the surfactant. Techniques involving on-line sample concentration, including sweeping micellar electrokinetic chromatography (sweeping-MEKC) and cation-selective exhaustive injection-sweep-micellar electrokinetic chromatography (CSEI-sweep-MEKC) were applied; the optimum on-line concentration and separation conditions were determined. In the analysis of an actual sample, LSD was found in a blood sample from a test mouse (0.1 mg LSD fed to a 20 g mouse; approximately 1/10 to the value of LD(50)). As a result, 120 and 30 ng/mL of LSD was detected at 20 and 60 min, respectively, after ingestion of the doses.

  12. Determination of tetraalkyllead compounds in gasoline by liquid chromatography-atomic absorption spectrometry

    USGS Publications Warehouse

    Messman, J.D.; Rains, T.C.

    1981-01-01

    A liquid chromatography-atomic absorption spectrometry (LC-AAS) hybrid analytical technique is presented for metal speciation measurements on complex liquid samples. The versatility and inherent metal selectivity of the technique are Illustrated by the rapid determination of five tetraalkyllead compounds in commercial gasoline. Separation of the individual tetraalkyllead species is achieved by reversed-phase liquid chromatography using an acetonitrile/water mobile phase. The effluent from the liquid Chromatograph Is introduced directly into the aspiration uptake capillary of the nebulizer of an air/acetylene flame atomic absorption spectrometer. Spectral interferences due to coeluting hydrocarbon matrix constituents were not observed at the 283.3-nm resonance line of lead used for analysis. Detection limits of this LC-AAS hydrid analytical technique, based on a 20-??L injection, are approximately 10 ng Pb for each tetraalkyllead compound.

  13. Continuous inline blending of antimisting kerosene

    NASA Technical Reports Server (NTRS)

    Parikh, P.; Yavrouian, A.; Sarohia, V.

    1985-01-01

    A continuous inline blender was developed to blend polymer slurries with a stream of jet A fuel. The viscosity of the slurries ranged widely. The key element of the blender was a static mixer placed immediately downstream of the slurry injection point. A positive displacement gear pump for jet A was employed, and a progressive cavity rotary screw pump was used for slurry pumping. Turbine flow meters were employed for jet A metering while the slurry flow rate was calibrated against the pressure drop in the injection tube. While using one of the FM-9 variant slurries, a provision was made for a time delay between the addition of slurry and the addition of amine sequentially into the jet A stream.

  14. Optimization of 64-MDCT urography: effect of dual-phase imaging with furosemide on collecting system opacification and radiation dose.

    PubMed

    Portnoy, Orith; Guranda, Larisa; Apter, Sara; Eiss, David; Amitai, Marianne Michal; Konen, Eli

    2011-11-01

    The purpose of this study was to compare opacification of the urinary collecting system and radiation dose associated with three-phase 64-MDCT urographic protocols and those associated with a split-bolus dual-phase protocol including furosemide. Images from 150 CT urographic examinations performed with three scanning protocols were retrospectively evaluated. Group A consisted of 50 sequentially registered patients who underwent a three-phase protocol with saline infusion. Group B consisted of 50 sequentially registered patients who underwent a reduced-radiation three-phase protocol with saline. Group C consisted of 50 sequentially registered patients who underwent a dual-phase split-bolus protocol that included a low-dose furosemide injection. Opacification of the urinary collecting system was evaluated with segmental binary scoring. Contrast artifacts were evaluated, and radiation doses were recorded. Results were compared by analysis of variance. A significant reduction in mean effective radiation dose was found between groups A and B (p < 0.001) and between groups B and C (p < 0.001), resulting in 65% reduction between groups A and C (p < 0.001). This reduction did not significantly affect opacification score in any of the 12 urinary segments (p = 0.079). In addition, dense contrast artifacts overlying the renal parenchyma observed with the three-phase protocols (groups A and B) were avoided with the dual-phase protocol (group C) (p < 0.001). A dual-phase protocol with furosemide injection is the preferable technique for CT urography. In comparison with commonly used three-phase protocols, the dual-phase protocol significantly reduces radiation exposure dose without reduction in image quality.

  15. SR high-speed K-edge subtraction angiography in the small animal (abstract)

    NASA Astrophysics Data System (ADS)

    Takeda, T.; Akisada, M.; Nakajima, T.; Anno, I.; Ueda, K.; Umetani, K.; Yamaguchi, C.

    1989-07-01

    To assess the ability of the high-speed K-edge energy subtraction system which was made at beamline 8C of Photon Factory, Tsukuba, we performed an animal experiment. Rabbits were used for the intravenous K-edge subtraction angiography. In this paper, the actual images of the artery obtained by this system, are demonstrated. The high-speed K-edge subtraction system consisted of movable silicon (111) monocrystals, II-ITV, and digital memory system. Image processing was performed by 68000-IP computer. The monochromatic x-ray beam size was 50×60 mm. Photon energy above and below iodine K edge was changed within 16 ms and 32 frames of images were obtained sequentially. The rabbits were anaesthetized by phenobarbital and a 5F catheter was inserted into inferior vena cava via the femoral vein. 1.5 ml/kg of contrast material (Conlaxin H) was injected at the rate of 0.5 ml/kg/s. TV images were obtained 3 s after the starting point of injection. By using this system, the clear K-edge subtracted images were obtained sequentially as a conventional DSA system. The quality of the images were better than that obtained by DSA. The dynamical blood flow was analyzed, and the best arterial image could be selected from the sequential images. The structures of aortic arch, common carotid arteries, right subclavian artery, and internal thoracic artery were obtained at the chest. Both common carotid arteries and vertebral arteries were recorded at the neck. The diameter of about 0.3-0.4 mm artery could be clearly revealed. The high-speed K-edge subtraction system demonstrates the very sharp arterial images clearly and dynamically.

  16. Concomitant or sequential administration of live attenuated japanese encephalitis chimeric virus vaccine and yellow fever 17D vaccine

    PubMed Central

    Nasveld, Peter E; Marjason, Joanne; Bennett, Sonya; Aaskov, John; Elliott, Suzanne; McCarthy, Karen; Kanesa-thasan, Niranjan; Feroldi, Emmanuel

    2010-01-01

    A randomized, double-blind, study was conducted to evaluate the safety, tolerability and immunogenicity of a live attenuated Japanese encephalitis chimeric virus vaccine (JE-CV) co-administered with live attenuated yellow fever (YF) vaccine (YF-17D strain; Stamaril®, Sanofi Pasteur) or administered sequentially. Participants (n = 108) were randomized to receive: YF followed by JE-CV 30 days later, JE followed by YF 30 days later, or the co-administration of JE and YF followed or preceded by placebo 30 days later or earlier. Placebo was used in a double-dummy fashion to ensure masking. Neutralizing antibody titers against JE-CV, YF-17D and selected wild-type JE virus strains was determined using a 50% serum-dilution plaque reduction neutralization test (PRNT50). Seroconversion was defined as the appearance of a neutralizing antibody titer above the assay cut-off post-immunization when not present pre-injection at day 0, or a least a four-fold rise in neutralizing antibody titer measured before the pre-injection day 0 and later post vaccination samples. There were no serious adverse events. Most adverse events (AEs) after JE vaccination were mild to moderate in intensity, and similar to those reported following YF vaccination. Seroconversion to JE-CV was 100% and 91% in the JE/YF and YF/JE sequential vaccination groups, respectively, compared with 96% in the co-administration group. All participants seroconverted to YF vaccine and retained neutralizing titers above the assay cut-off at month six. Neutralizing antibodies against JE vaccine were detected in 82–100% of participants at month six. These results suggest that both vaccines may be successfully co-administered simultaneously or 30 days apart. PMID:20864814

  17. Electrochemical immunoassay for vitellogenin based on sequential injection using antigen-immobilized magnetic microbeads.

    PubMed

    Hirakawa, Koji; Katayama, Masaaki; Soh, Nobuaki; Nakano, Koji; Imato, Toshihiko

    2006-01-01

    A rapid and sensitive immunoassay for the determination of vitellogenin (Vg) is described. The method involves a sequential injection analysis (SIA) system equipped with an amperometric detector and a neodymium magnet. Magnetic beads, onto which an antigen (Vg) was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of magnetic beads in an immunoreaction cell were controlled by means of the neodymium magnet and by adjusting the flow of the carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an alkaline phosphatase (ALP) labeled anti-Vg monoclonal antibody between the fraction of Vg immobilized on the magnetic beads and Vg in the sample solution. The immobilization of Vg on the beads involved coupling an amino group moiety of Vg with the magnetic beads after activation of a carboxylate moiety on the surface of magnetic beads that had been coated with a polylactate film. The Vg-immobilized magnetic beads were introduced and trapped in the immunoreaction cell equipped with the neodymium magnet; a Vg sample solution containing an ALP labeled anti-Vg antibody at a constant concentration and a p-aminophenyl phosphate (PAPP) solution were sequentially introduced into the immunoreaction cell. The product of the enzyme reaction of PAPP with ALP on the antibody, paminophenol, was transported to an amperometric detector, the applied voltage of which was set at +0.2 V vs. an Ag/AgCl reference electrode. A sigmoid calibration curve was obtained when the logarithm of the concentration of Vg was plotted against the peak current of the amperometric detector using various concentrations of standard Vg sample solutions (0-500 ppb). The time required for the analysis is less than 15 min.

  18. Liquid chromatography mass spectrometry determination of perfluoroalkyl acids in environmental solid extracts after phospholipid removal and on-line turbulent flow chromatography purification.

    PubMed

    Mazzoni, M; Polesello, S; Rusconi, M; Valsecchi, S

    2016-07-01

    An on-line TFC (Turbulent Flow Chromatography) clean up procedures coupled with UHPLC-MS/MS (Ultra High Performance Liquid Chromatography Mass Spectrometry) multi-residue method was developed for the simultaneous determination of 8 perfluroalkyl carboxylic acids (PFCA, from 5 to 12 carbon atoms) and 3 perfluoroalkyl sulfonic acids (PFSA, from 4 to 8 carbon atoms) in environmental solid matrices. Fast sample preparation procedure was based on a sonication-assisted extraction with acetonitrile. Phospholipids in biological samples were fully removed by an off-line SPE purification before injection, using HybridSPE(®) Phospholipid Ultra cartridges. The development of the on-line TFC clean-up procedure regarded the choice of the stationary phase, the optimization of the mobile phase composition, flow rate and injected volume. The validation of the optimized method included the evaluation of matrix effects, accuracy and reproducibility. Signal suppression in the analysis of fortified extracts ranged from 1 to 60%, and this problem was overcome by using isotopic dilution. Since no certified reference materials were available for PFAS in these matrices, accuracy was evaluated by recoveries on spiked clam samples which were 98-133% for PFCAs and 40-60% for PFSAs. MLDs and MLQs ranged from 0.03 to 0.3ngg(-1) wet weight and from 0.1 to 0.9ngg(-1) wet weight respectively. Repeatability (intra-day precision) and reproducibility (inter-day precision) showed RSD from 3 to 13% and from 4 to 27% respectively. Validated on-line TFC/UHPLC-MS/MS method has been applied for the determination of perfluoroalkyl acids in different solid matrices (sediment, fish, bivalves and bird yolk). Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Sequential variable fuel injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weglarz, M.W.; Vincent, M.T.; Prestel, J.F.

    This patent describes a fuel injection system for an engine of an automotive vehicle including cylinders, a spark plug for each of the cylinders, a distributor electrically connected to the spark plug, a throttle body having a throttle valve connected to the engine to allow or prevent air to the cylinders, a fuel source at least one fuel line connected to the fuel source, fuel injectors connected to the fuel line for delivering fuel to the cylinders, a sensor located near the distributor for sensing predetermined states of the distributor, and an electronic control unit (ECU) electrically connected to themore » sensor, distributor and fuel injectors. It comprises calculating a desired total injector on time for current engine conditions; calculating a variable injection time (VIT) and a turn on time based on the VIT; and firing the fuel injectors at the calculated turn on time for the calculated total injector on time.« less

  20. Analysis of selected antibiotics in surface freshwater and seawater using direct injection in liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Bayen, Stéphane; Yi, Xinzhu; Segovia, Elvagris; Zhou, Zhi; Kelly, Barry C

    2014-04-18

    Emerging contaminants such as antibiotics have received recent attention as they have been detected in natural waters and health concerns over potential antibiotic resistance. With the purpose to investigate fast and high-throughput analysis, and eventually the continuous on-line analysis of emerging contaminants, this study presents results on the analysis of seven selected antibiotics (sulfadiazine, sulfamethazine, sulfamerazine, sulfamethoxazole, chloramphenicol, lincomycin, tylosin) in surface freshwater and seawater using direct injection of a small sample volume (20μL) in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Notably, direct injection of seawater in the LC-ESI-MS/MS was made possible on account of the post-column switch on the system, which allows diversion of salt-containing solutions flushed out of the column to the waste. Mean recoveries based on the isotope dilution method average 95±14% and 96±28% amongst the compounds for spiked freshwater and seawater, respectively. Linearity across six spiking levels was assessed and the response was linear (r(2)>0.99) for all compounds. Direct injection concentrations were compared for real samples to those obtained with the conventional SPE-based analysis and both techniques concurs on the presence/absence and levels of the compounds in real samples. These results suggest direct injection is a reliable method to detect antibiotics in both freshwater and seawater. Method detection limits for the direct injection technique (37pg/L to 226ng/L in freshwater, and from 16pg/to 26ng/L in seawater) are sufficient for a number of environmental applications, for example the fast screening of water samples for ecological risk assessments. In the present study of real samples, this new method allowed for example the positive detection of some compounds (e.g. lincomycin) down to the sub ng/L range. The direct injection method appears to be relatively cheaper and faster, requires a smaller sample size, and is more robust to equipment cross-contamination as compared to the conventional SPE-based method. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Optimizations of packed sorbent and inlet temperature for large volume-direct aqueous injection-gas chromatography to determine high boiling volatile organic compounds in water.

    PubMed

    Yu, Bofan; Song, Yonghui; Han, Lu; Yu, Huibin; Liu, Yang; Liu, Hongliang

    2014-08-22

    For the expanded application area, fast trace analysis of certain high boiling point (i.e., 150-250 °C) volatile organic compounds (HVOCs) in water, a large volume-direct aqueous injection-gas chromatography (LV-DAI-GC) method was optimized for the following parameters: packed sorbent for sample on-line pretreatment, inlet temperature and detectors configuration. Using the composite packed sorbent self-prepared with lithium chloride and a type of diatomite, the method enabled safe injection of an approximately 50-100 μL sample at an inlet temperature of 150 °C in the splitless mode and separated HVOCs from water matrix in 2 min. Coupled with a flame ionization detector (FID), an electron capture detector (ECD) and a flame photometric detector (FPD), the method could simultaneously quantify 27 HVOCs that belong to seven subclasses (i.e., halogenated aliphatic hydrocarbons, chlorobenzenes, nitrobenzenes, anilines, phenols, polycyclic aromatic hydrocarbons and organic sulfides) in 26 min. Injecting a 50 μL sample without any enrichment step, such as cryotrap focusing, the limits of quantification (LOQs) for the 27 HVOCs was 0.01-3 μg/L. Replicate analyses of the 27 HVOCs spiked source and river water samples exhibited good precision (relative standard deviations ≤ 11.3%) and accuracy (relative errors ≤ 17.6%). The optimized LV-DAI-GC was robust and applicable for fast determination and automated continuous monitoring of HVOCs in surface water. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Investigation of modulation parameters in multiplexing gas chromatography.

    PubMed

    Trapp, Oliver

    2010-10-22

    Combination of information technology and separation sciences opens a new avenue to achieve high sample throughputs and therefore is of great interest to bypass bottlenecks in catalyst screening of parallelized reactors or using multitier well plates in reaction optimization. Multiplexing gas chromatography utilizes pseudo-random injection sequences derived from Hadamard matrices to perform rapid sample injections which gives a convoluted chromatogram containing the information of a single sample or of several samples with similar analyte composition. The conventional chromatogram is obtained by application of the Hadamard transform using the known injection sequence or in case of several samples an averaged transformed chromatogram is obtained which can be used in a Gauss-Jordan deconvolution procedure to obtain all single chromatograms of the individual samples. The performance of such a system depends on the modulation precision and on the parameters, e.g. the sequence length and modulation interval. Here we demonstrate the effects of the sequence length and modulation interval on the deconvoluted chromatogram, peak shapes and peak integration for sequences between 9-bit (511 elements) and 13-bit (8191 elements) and modulation intervals Δt between 5 s and 500 ms using a mixture of five components. It could be demonstrated that even for high-speed modulation at time intervals of 500 ms the chromatographic information is very well preserved and that the separation efficiency can be improved by very narrow sample injections. Furthermore this study shows that the relative peak areas in multiplexed chromatograms do not deviate from conventionally recorded chromatograms. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Spatial and Temporal Distribution of Imidacloprid Within the Crown of Eastern Hemlock.

    PubMed

    Turcotte, Richard M; Lagalante, Anthony; Jones, Jonathan; Cook, Frank; Elliott, Thomas; Billings, Anthony A; Park, Yong-Lak

    2017-01-01

    Systemic imidacloprid is the most widely used insecticide to control the hemlock woolly adelgid, Adelges tsugae Annand (Hemiptera: Adelgidae), an exotic pest of eastern hemlock, Tsuga canadensis (L.) Carriére in the United States. This study was conducted to 1) determine the effect of treatment timing (spring vs. fall) and application method (trunk injection vs. soil injection) on the spatial and temporal distribution of imidacloprid within the crown of A. tsugae-free eastern hemlock using a competitive enzyme-linked immunosorbent assay (ELISA), 2) compare ELISA to gas chromatography-mass spectrometry (GC/MS) for the detection of imidacloprid in xylem fluid, and 3) determine the concentration of imidacloprid in leaf tissue using high performance liquid chromatography with tandem mass spectrometric (LC/MS/MS) detection methods. Xylem fluid concentrations of imidacloprid were found to be significantly higher for spring applications than for fall applications and for trunk injections than soil injections in the first year posttreatment. A total of 69% of samples analyzed by ELISA gave 1.8 times higher concentrations of imidacloprid than those found by GC/MS, leading to evidence of a matrix effect and overestimation of imidacloprid in xylem fluid by ELISA. A comparison of the presence of imidacloprid with xylem fluid and in leaf tissue on the same branch showed significant differences, suggesting that imidacloprid moved intermittently within the crown of eastern hemlock. Published by Oxford University Press on behalf of the Entomological Society of America 2017. This work is written by US Government employees and is in the public domain in the US.

  4. Preparation and evaluation of Lu-177 phytate Complex for Radiosynovectomy

    PubMed Central

    Yousefnia, Hassan; Jalilian, Amir Reza; Zolghadri, Samaneh

    2014-01-01

    Lu-177 of 2.6-3 GBq/mg specific activity was obtained by irradiation of natural Lu2O3 sample with thermal neutron flux of 4 × 1013 n/cm/s. The product was converted into chloride form which was further used for labeling of Lu-177 phytate complex successfully with high radiochemical purity (>99.9%, instant thin layer chromatography, MeOH: H2O: Acetic acid, 4:4:2, as mobile phase). The complex stability and viscosity were checked in the final solution up to 7 days. The prepared complex solution (100 μCi/100 μl) was injected intra-articularly to the male rat knee joint. Leakage of radioactivity from the injection site and its distribution in organs were investigated up to 7 days. Approximately, all injected dose has remained in injection site 7 days after injection. The complex was proved to be a feasible agent for cavital radiotherapy in oncology and rheumatology. PMID:25191108

  5. Evaluation of Bufadienolides as the Main Antitumor Components in Cinobufacin Injection for Liver and Gastric Cancer Therapy.

    PubMed

    Wei, Xiaolu; Si, Nan; Zhang, Yuefei; Zhao, Haiyu; Yang, Jian; Wang, Hongjie; Wang, Lianmei; Han, Linyu; Bian, Baolin

    2017-01-01

    Cinobufacin injection, also known as huachansu, is a preparation form of Cinobufacini made from Cinobufacin extract liquid. Despite that Cinobufacin injection is shown to shrink liver and gastric tumors, improving patient survival and life quality, the effective components in Cinobufacin remain elusive. In this study, we aim to screen antitumor components from Cinobufacin injection to elucidate the most effective antitumor components for treatment of liver and gastric cancers. High performance liquid chromatography (HPLC) and LC-MS/MS analysis were used to separate and determine the components in Cinobufacin injection. Inhibition rates of various components in Cinobufacin injection on liver and gastric cancer cells were determined with MTT assay; Hepatocellular carcinoma and gastric cancer models were used to assess the antitumor effect of the compounds in vivo. The major constituents in Cinobufacin injection include peptides, nucleic acids, tryptamines and bufotalins. MTT assay revealed that bufadienolides had the best antitumor activity, with peptides being the second most effective components. Bufadienolides showed significant inhibition rates on gastric and hepatocellular tumour growth in vivo. Bufadienolides are the most effective components in Cinobufacini injection for the treatment of liver and gastric cancers. This discovery can greatly facilitate further research in improving the therapeutic effects of Cinobufacin injection, meanwhile reducing its adverse reaction.

  6. Solid State Television Camera (CID)

    NASA Technical Reports Server (NTRS)

    Steele, D. W.; Green, W. T.

    1976-01-01

    The design, development and test are described of a charge injection device (CID) camera using a 244x248 element array. A number of video signal processing functions are included which maximize the output video dynamic range while retaining the inherently good resolution response of the CID. Some of the unique features of the camera are: low light level performance, high S/N ratio, antiblooming, geometric distortion, sequential scanning and AGC.

  7. Kinetics of the neuroinflammation-oxidative stress correlation in rat brain following the injection of fibrillar amyloid-beta onto the hippocampus in vivo.

    PubMed

    Rosales-Corral, Sergio; Tan, Dun-Xian; Reiter, Russel J; Valdivia-Velázquez, Miguel; Acosta-Martínez, J Pablo; Ortiz, Genaro G

    2004-05-01

    The purpose of this study was to describe-following the injection of a single intracerebral dose of fibrillar amyloid-beta(1-40) in vivo-some correlations between proinflammatory cytokines and oxidative stress indicators in function of time, as well as how these variables fit in a regression model. We found a positive, significant correlation between interleukin (IL)-1beta or IL-6 and the activity of the glutathione peroxidase enzyme (GSH-Px), but IL-1beta or IL-6 maintained a strong, negative correlation with the lipid peroxidation (LPO). The first 12 h marked a positive correlation between IL-6 and tumor necrosis factor-alpha (TNF-alpha), but starting from the 36 h, this relationship became negative. We found also particular patterns of behavior through the time for IL-1beta, nitrites and IL-6, with parallel or sequential interrelationships. Results shows clearly that, in vivo, the fibrillar amyloid-beta (Abeta) disrupts the oxidative balance and initiate a proinflammatory response, which in turn feeds the oxidative imbalance in a coordinated, sequential way. This work contributes to our understanding of the positive feedbacks, focusing the "cytokine cycle" along with the oxidative stress mediators in a complex, multicellular, and interactive environment.

  8. The sequential injection system with adsorptive stripping voltammetric detection.

    PubMed

    Kubiak, W W; Latonen, R M; Ivaska, A

    2001-03-16

    Two sequential injection systems have been developed for adsorptive stripping voltammetric measurement. One is for substances adsorbing at mercury, e.g. riboflavin. In this case, a simple arrangement with only sample aspiration is needed. Reproducibility was 3% and detection limit 0.07 muM. The measuring system was applied to determination of riboflavin in vitamin pills and to study the photodegradation process of riboflavin in aqueous solutions. In the second case, metal ions were determined. They have to be complexed before deposition on the mercury surface. Thus, both the sample and the ligand have to be aspirated in the system. In this case, the reproducibility was approximately 6% and the detection limit <0.1 ppm for cadmium, lead and copper when complexation with oxine was used. Dimethylglyoxime was used in determination of nickel and cobalt and nioxime complexes were used in determination of nickel and copper. With these complexing agents, the reproducibility was the same as with oxine, but the metals could be determined at concentrations lower than 0.01 ppm. Application of two ligands in a SIA system with AdSV detection was also studied. Simultaneous determination of copper, lead, cadmium and cobalt was possible by using oxine and dimethylglyoxime. Copper and nickel were simultaneously determined by using dimethylglyoxime and nioxime.

  9. A 400 MHz Wireless Neural Signal Processing IC With 625 $\\times$ On-Chip Data Reduction and Reconfigurable BFSK/QPSK Transmitter Based on Sequential Injection Locking.

    PubMed

    Teng, Kok-Hin; Wu, Tong; Liu, Xiayun; Yang, Zhi; Heng, Chun-Huat

    2017-06-01

    An 8-channel wireless neural signal processing IC, which can perform real-time spike detection, alignment, and feature extraction, and wireless data transmission is proposed. A reconfigurable BFSK/QPSK transmitter (TX) at MICS/MedRadio band is incorporated to support different data rate requirement. By using an Exponential Component-Polynomial Component (EC-PC) spike processing unit with an incremental principal component analysis (IPCA) engine, the detection of neural spikes with poor SNR is possible while achieving 625× data reduction. For the TX, a dual-channel at 401 MHz and 403.8 MHz are supported by applying sequential injection locked techniques while attaining phase noise of -102 dBc/Hz at 100 kHz offset. From the measurement, error vector magnitude (EVM) of 4.60%/9.55% with power amplifier (PA) output power of -15 dBm is achieved for the QPSK at 8 Mbps and the BFSK at 12.5 kbps. Fabricated in 65 nm CMOS with an active area of 1 mm 2 , the design consumes a total current of 5  ∼ 5.6 mA with a maximum energy efficiency of 0.7 nJ/b.

  10. Bioremediation of PAHs contaminated river sediment by an integrated approach with sequential injection of co-substrate and electron acceptor: Lab-scale study.

    PubMed

    Liu, Tongzhou; Zhang, Zhen; Dong, Wenyi; Wu, Xiaojing; Wang, Hongjie

    2017-11-01

    In this study, the feasibility of employing an integrated bioremediation approach in contaminated river sediment was evaluated. Sequential addition of co-substrate (acetate) and electron acceptor (NO 3 - ) in a two-phase treatment was capable of effectively removing polycyclic aromatic hydrocarbons (PAHs) in river sediment. The residual concentration of total PAHs decreased to far below effect range low (ERL) value within 91 days of incubation, at which concentration it could rarely pose biological impairment. The biodegradation of high molecular weight PAHs were found to be mainly occurred in the sediment treated with co-substrates (i.e. acetate or methanol), in which acetate was found to be more suitable for PAHs degradation. The role of co-substrates in influencing PAHs biodegradation was tentatively discussed herein. Additionally, the sediment odorous problem and blackish appearance were intensively addressed by NO 3 - injection. The results of this study demonstrated that integrating two or more approaches/processes would be a helpful option in sediment remediation. It can lead to a more effective remediation performance, handle multiple contamination issues, as well as mitigate environmental risks caused by one of the single methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Prime-boost vaccination with plasmid and adenovirus gene vaccines control HER2/neu+ metastatic breast cancer in mice.

    PubMed

    Wang, Xiaoyan; Wang, Jian-Ping; Rao, Xiao-Mei; Price, Janet E; Zhou, Heshan S; Lachman, Lawrence B

    2005-01-01

    Once metastasis has occurred, the possibility of completely curing breast cancer is unlikely, particularly for the 30 to 40% of cancers overexpressing the gene for HER2/neu. A vaccine targeting p185, the protein product of the HER2/neu gene, could have therapeutic application by controlling the growth and metastasis of highly aggressive HER2/neu+ cells. The purpose of this study was to determine the effectiveness of two gene vaccines targeting HER2/neu in preventive and therapeutic tumor models. The mouse breast cancer cell line A2L2, which expresses the gene for rat HER2/neu and hence p185, was injected into the mammary fat pad of mice as a model of solid tumor growth or was injected intravenously as a model of lung metastasis. SINCP-neu, a plasmid containing Sindbis virus genes and the gene for rat HER2/neu, and Adeno-neu, an E1,E2a-deleted adenovirus also containing the gene for rat HER2/neu, were tested as preventive and therapeutic vaccines. Vaccination with SINCP-neu or Adeno-neu before tumor challenge with A2L2 cells significantly inhibited the growth of the cells injected into the mammary fat or intravenously. Vaccination 2 days after tumor challenge with either vaccine was ineffective in both tumor models. However, therapeutic vaccination in a prime-boost protocol with SINCP-neu followed by Adeno-neu significantly prolonged the overall survival rate of mice injected intravenously with the tumor cells. Naive mice vaccinated using the same prime-boost protocol demonstrated a strong serum immunoglobulin G response and p185-specific cellular immunity, as shown by the results of ELISPOT (enzyme-linked immunospot) analysis for IFNgamma. We report herein that vaccination of mice with a plasmid gene vaccine and an adenovirus gene vaccine, each containing the gene for HER2/neu, prevented growth of a HER2/neu-expressing breast cancer cell line injected into the mammary fat pad or intravenously. Sequential administration of the vaccines in a prime-boost protocol was therapeutically effective when tumor cells were injected intravenously before the vaccination. The vaccines induced high levels of both cellular and humoral immunity as determined by in vitro assessment. These findings indicate that clinical evaluation of these vaccines, particularly when used sequentially in a prime-boost protocol, is justified.

  12. Analysis of benzo(a)pyrene in airborne particulates by gas chromatography

    NASA Technical Reports Server (NTRS)

    Luedecke, E.

    1976-01-01

    A routine method was developed to measure benzo(a)pyrene in airborne particulates. Samples were collected on a filter and the organic portion was extracted with cyclohexane. The polynuclear hydrocarbon (PNHC) fraction was separated from the aliphatics by column chromatography. An internal standard was added to the extract and a portion of it was injected into a gas chromatograph. Although the gas chromatographic method has often been reported in the literature, satisfactory separation of benzo(a)pyrene and benzo(e)pyrene has not been achieved. With the introduction of a nematic liquid crystal as the stationary phase good separation is now possible.

  13. Highly selective solid-phase extraction and large volume injection for the robust gas chromatography-mass spectrometric analysis of TCA and TBA in wines.

    PubMed

    Insa, S; Anticó, E; Ferreira, V

    2005-09-30

    A reliable solid-phase extraction (SPE) method for the simultaneous determination of 2,4,6-trichloroanisole (TCA) and 2,4,6-tribromoanisole (TBA) in wines has been developed. In the proposed procedure 50 mL of wine are extracted in a 1 mL cartridge filled with 50 mg of LiChrolut EN resins. Most wine volatiles are washed up with 12.5 mL of a water:methanol solution (70%, v/v) containing 1% of NaHCO3. Analytes are further eluted with 0.6 mL of dichloromethane. A 40 microL aliquot of this extract is directly injected into a PTV injector operated in the solvent split mode, and analysed by gas chromatography (GC)-ion trap mass spectrometry using the selected ion storage mode. The solid-phase extraction, including sample volume and rinsing and elution solvents, and the large volume GC injection have been carefully evaluated and optimized. The resulting method is precise (RSD (%) < 6% at 100 ng L(-1)), sensitive (LOD were 0.2 and 0.4 ng/L for TCA and TBA, respectively), robust (the absolute recoveries of both analytes are higher than 80% and consistent wine to wine) and friendly to the GC-MS system (the extract is clean, simple and free from non-volatiles).

  14. Human Growth Hormone Delivery with a Microneedle Transdermal System: Preclinical Formulation, Stability, Delivery and PK of Therapeutically Relevant Doses

    PubMed Central

    Ameri, Mahmoud; Kadkhodayan, Miryam; Nguyen, Joe; Bravo, Joseph A.; Su, Rebeca; Chan, Kenneth; Samiee, Ahmad; Daddona, Peter E.

    2014-01-01

    This study evaluated the feasibility of coating formulated recombinant human growth hormone (rhGH) on a titanium microneedle transdermal delivery system, Zosano Pharma (ZP)-hGH, and assessed preclinical patch delivery performance. Formulation rheology and surface activity were assessed by viscometry and contact angle measurement. rhGH liquid formulation was coated onto titanium microneedles by dip-coating and drying. The stability of coated rhGH was determined by size exclusion chromatography-high performance liquid chromatography (SEC-HPLC). Preclinical delivery and pharmacokinetic studies were conducted in female hairless guinea pigs (HGP) using rhGH coated microneedle patches at 0.5 and 1 mg doses and compared to Norditropin® a commercially approved rhGH subcutaneous injection. Studies demonstrated successful rhGH formulation development and coating on microneedle arrays. The ZP-hGH patches remained stable at 40 °C for six months with no significant change in % aggregates. Pharmacokinetic studies showed that the rhGH-coated microneedle patches, delivered with high efficiency and the doses delivered indicated linearity with average Tmax of 30 min. The absolute bioavailability of the microneedle rhGH patches was similar to subcutaneous Norditropin® injections. These results suggest that ZP-transdermal microneedle patch delivery of rhGH is feasible and may offer an effective and patient-friendly alternative to currently marketed rhGH injectables. PMID:24838219

  15. Electrochemical attosyringe.

    PubMed

    Laforge, François O; Carpino, James; Rotenberg, Susan A; Mirkin, Michael V

    2007-07-17

    The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10(-18) to 10(-12) liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems.

  16. Electrochemical attosyringe

    PubMed Central

    Laforge, François O.; Carpino, James; Rotenberg, Susan A.; Mirkin, Michael V.

    2007-01-01

    The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10−18 to 10−12 liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems. PMID:17620612

  17. Rapid isolation of biomarkers for compound specific radiocarbon dating using high-performance liquid chromatography and flow injection analysis-atmospheric pressure chemical ionisation mass spectrometry.

    PubMed

    Smittenberg, Rienk H; Hopmans, Ellen C; Schouten, Stefan; Sinninghe Damsté, Jaap S

    2002-11-29

    Repeated semi-preparative normal-phase HPLC was performed to isolate selected biomarkers from sediment extracts for radiocarbon analysis. Flow injection analysis-mass spectrometry was used for rapid analysis of collected fractions to evaluate the separation procedure, taking only 1 min per fraction. In this way 100-1000 microg of glycerol dialkyl glycerol tetraethers, sterol fractions and chlorophyll-derived phytol were isolated from typically 100 g of marine sediment, i.e., in sufficient quantities for radiocarbon analysis, without significant carbon isotopic fractionation or contamination.

  18. PULSED SPLITLESS AND LARGE-VOLUME INJECTION IN CAPILLARY GAS CHROMATOGRAPHY MASS SPECTROMETRY FOR THE DETERMINATION OF ULTRA-TRACE LEVEL PESTICIDE RESIDUES

    EPA Science Inventory

    The possible presence of ultra-trace levels (sub- parts per trillion) of pesticides in pristine aquatic environments (e.g., alpine lakes) would raise questions regarding potential effects on biota. One hypothesis is that agricultural pesticides that are heavily applied in the San...

  19. RAPID AND PRECISE METHOD FOR MEASURING STABLE CARBON ISOTOPE RATIOS OF DISSOLVED INORGANIC CARBON

    EPA Science Inventory

    We describe a method for rapid preparation, concentration and stable isotopic analysis of dissolved inorganic carbon (d13C-DIC). Liberation of CO2 was accomplished by placing 100 ?l phosphoric acid and 0.9 ml water in an evacuated 1.7-ml gas chromatography (GC) injection vial. Fo...

  20. Flow Injection Analysis and Liquid Chromatography for Multifunctional Chemical Analysis (MCA) Systems

    ERIC Educational Resources Information Center

    Mayo, Ana V.; Loegel, Thomas N.; Bretz, Stacey Lowery; Danielson, Neil D.

    2013-01-01

    The large class sizes of first-year chemistry labs makes it challenging to provide students with hands-on access to instrumentation because the number of students typically far exceeds the number of research-grade instruments available to collect data. Multifunctional chemical analysis (MCA) systems provide a viable alternative for large-scale…

  1. A selective and sensitive method for quantitation of lysergic acid diethylamide (LSD) in whole blood by gas chromatography-ion trap tandem mass spectrometry.

    PubMed

    Libong, Danielle; Bouchonnet, Stéphane; Ricordel, Ivan

    2003-01-01

    A gas chromatography-ion trap tandem mass spectrometry (GC-ion trap MS-MS) method for detection and quantitation of LSD in whole blood is presented. The sample preparation process, including a solid-phase extraction step with Bond Elut cartridges, was performed with 2 mL of whole blood. Eight microliters of the purified extract was injected with a cold on-column injection method. Positive chemical ionization was performed using acetonitrile as reagent gas; LSD was detected in the MS-MS mode. The chromatograms obtained from blood extracts showed the great selectivity of the method. GC-MS quantitation was performed using lysergic acid methylpropylamide as the internal standard. The response of the MS was linear for concentrations ranging from 0.02 ng/mL (detection threshold) to 10.0 ng/mL. Several parameters such as the choice of the capillary column, the choice of the internal standard and that of the ionization mode (positive CI vs. EI) were rationalized. Decomposition pathways under both ionization modes were studied. Within-day and between-day stability were evaluated.

  2. Offline Solid-phase Extraction Large-volume Injection-Gas chromatography for the Analysis of Mineral Oil-saturated Hydrocarbons in Commercial Vegetable Oils.

    PubMed

    Liu, Lingling; Huang, Hua; Wu, Yanwen; Li, Bingning; Ouyang, Jie

    2017-09-01

    An offline solid-phase extraction (SPE) approach combined with a large-volume injection (LVI)-gas chromatography-flame ionization detector (LVI-GC-FID) is improved for routine analysis of mineral oil saturated hydrocarbons (MOSH) in vegetable oils. The key procedure of the method consists in using offline SPE columns for MOSH purification. The SPE column packed with 1% Ag-activated silica gel was used to separate MOSH from triglycerides and olefins in variety of vegetable oils. The eluent of MOSH fraction was only 3 mL and the concentration step was quick with little evaporation loss. The limit of quantification (LOQ) of the method was 2.5 mg/kg and the linearity ranged from 2 to 300 mg/kg. The accuracy was assessed by measuring the recoveries from spiked oil samples and was higher than 90%. Twenty-seven commercial vegetable oils were analyzed, and different levels of MOSH contamination were detected with the highest being 259.4 mg/kg. The results suggested that it is necessary to routinely detect mineral oil contamination in vegetable oils for food safety.

  3. Method and apparatus for scientific analysis under low temperature vacuum conditions

    DOEpatents

    Winefordner, James D.; Jones, Bradley T.

    1990-01-01

    A method and apparatus for scientific analysis of a sample under low temperature vacuum conditions uses a vacuum chamber with a conveyor belt disposed therein. One end of the conveyor belt is a cool end in thermal contact with the cold stage of a refrigerator, whereas the other end of the conveyor belt is a warm end spaced from the refrigerator. A septum allows injection of a sample into the vacuum chamber on top of the conveyor belt for spectroscopic or other analysis. The sample freezes on the conveyor belt at the cold end. One or more windows in the vacuum chamber housing allow spectroscopic analysis of the sample. Following the spectroscopic analysis, the conveyor belt may be moved such that the sample moves toward the warm end of the conveyor belt where upon it evaporates, thereby cleaning the conveyor belt. Instead of injecting the sample by way of a septum and use of a syringe and needle, the present device may be used in series with capillary-column gas chromatography or micro-bore high performance liquid chromatography.

  4. Identification of polar, ionic, and highly water soluble organic pollutants in untreated industrial wastewaters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castillo, M.; Alonso, M.C.; Riu, J.

    1999-04-15

    This paper presents a generic protocol for the determination of polar, ionic, and highly water soluble organic pollutants on untreated industrial wastewaters involving the use of two different solid-phase extraction (SPE) methodologies followed by liquid chromatography-mass spectrometry (LC-MS). Untreated industrial wastewaters might contain natural and synthetic dissolved organic compounds with total organic carbon (TOC) values varying between 100 and 3000 mg/L. All polar, ionic and highly water soluble compounds comprising more than 95% of the organic content and with major contribution to the total toxicity of the sample cannot be analyzed by conventional gas chromatography-mass spectrometry (GC-MS), and LC-MS ismore » a good alternative. In this work two extraction procedures were used to obtain fractionated extracts of the nonionic polar compounds: a polymeric Isolute ENV + SPE cartridge for the preconcentration of anionic analytes and a sequential solid-phase extraction (SSPE) method percolating the samples first in octadecylsilica cartridge in series with the polymeric Lichrolut EN cartridge. Average recoveries ranging from 72% to 103% were obtained for a variety of 23 different analytes. Determination of nonionic pollutants was accomplished by reverse-phase liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), while anionic compounds were analyzed by ion pair chromatography-electrospray-mass spectrometry (IP-ESI-MS) and LC-ESI-MS. This protocol was applied to a pilot survey of textile and tannery wastewaters leading to the identification and quantification of 33 organic pollutants.« less

  5. Lipidomics by Supercritical Fluid Chromatography

    PubMed Central

    Laboureur, Laurent; Ollero, Mario; Touboul, David

    2015-01-01

    This review enlightens the role of supercritical fluid chromatography (SFC) in the field of lipid analysis. SFC has been popular in the late 1980s and 1990s before almost disappearing due to the commercial success of liquid chromatography (LC). It is only 20 years later that a regain of interest appeared when new commercial instruments were introduced. As SFC is fully compatible with the injection of extracts in pure organic solvent, this technique is perfectly suitable for lipid analysis and can be coupled with either highly universal (UV or evaporative light scattering) or highly specific (mass spectrometry) detection methods. A short history of the use of supercritical fluids as mobile phase for the separation oflipids will be introduced first. Then, the advantages and drawbacks of SFC are discussed for each class of lipids (fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, prenols, polyketides) defined by the LIPID MAPS consortium. PMID:26090714

  6. Ultrafast gas chromatography method with direct injection for the quantitative determination of benzene, toluene, ethylbenzene, and xylenes in commercial gasoline.

    PubMed

    Miranda, Nahieh Toscano; Sequinel, Rodrigo; Hatanaka, Rafael Rodrigues; de Oliveira, José Eduardo; Flumignan, Danilo Luiz

    2017-04-01

    Benzene, toluene, ethylbenzene, and xylenes are some of the most hazardous constituents found in commercial gasoline samples; therefore, these components must be monitored to avoid toxicological problems. We propose a new routine method of ultrafast gas chromatography coupled to flame ionization detection for the direct determination of benzene, toluene, ethylbenzene, and xylenes in commercial gasoline. This method is based on external standard calibration to quantify each compound, including the validation step of the study of linearity, detection and quantification limits, precision, and accuracy. The time of analysis was less than 3.2 min, with quantitative statements regarding the separation and quantification of all compounds in commercial gasoline samples. Ultrafast gas chromatography is a promising alternative method to official analytical techniques. Government laboratories could consider using this method for quality control. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Non-planar microfabricated gas chromatography column

    DOEpatents

    Lewis, Patrick R.; Wheeler, David R.

    2007-09-25

    A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

  8. [Separation of alkaloids in tea by high-speed counter-current chromatography].

    PubMed

    Yuan, L; Fu, R; Zhang, T; Deng, J; Li, X

    1998-07-01

    Alkaloids extracted from the green tea were separated by high-speed counter-current chromatography. A series of experiments have been performed to investigate effects of different solvent system. A system of CHCl3-CH3OH-NaH2PO4(23 mmol/L) = (4:3:2) was selected, in which the upper phase was used as the stationary phase, and the lower phase as mobile phase. When acidity of solvent system is pH 5.6, three chemical components are very efficiently isolated by one injection of 50 mg sample mixture. Analyzing the eluted fractions by TLC, we know that one is caffeine, and the other is theophylline. In comparing the separation results by high-speed counter-current chromatography with those by TLC, the advantages of this method is verified. It should find wide applications of this technology for the separation of crude mixture of plant components.

  9. Isolation of Three Triterpene Saponins, Including Two New Oleanane Derivatives, from Soldanella alpina and Hydrophilic Interaction Liquid Chromatography-Evaporative Light Scattering Detection of these Three Saponins in Four Soldenella Species.

    PubMed

    Haller, Julia; Schwaiger, Stefan; Stuppner, Hermann; Gafner, Frank; Ganzera, Markus

    2017-11-01

    The genus Soldanella is one of the few endemic to Europe. Some of its species have relevance in local traditional medicine. Earlier work has indicated the possible presence of saponins in S. alpina. To investigate S. alpina and other related species for the occurrence of saponins. Following sequential extraction with n-hexane, dichloromethane and ethyl acetate the subsequent methanolic extract of S. alpina roots was fractionated after solvent precipitation using fast centrifugal partition chromatography and column chromatography. Structures were elucidated by LC-MS n , high-resolution MS, hydrolysis experiments and one-dimensional (1D)- and two-dimensional (2D)-NMR. A hydrophilic interaction liquid chromatography method was developed to quantitate saponins in the leaves and roots of four Soldanella species. Three triterpene saponins, two of them new natural products, were isolated from S. alpina. Based on an epoxyoleanal aglycone substituted with four sugar units, they were analytically quantitated using a Kinetex 2.6 μm hydrophilic interaction liquid chromatography (HILIC) column together with a mobile phase comprising of ammonium acetate, water and acetonitrile. Method validation confirmed that the assay meets all requirements in respect to linearity, accuracy, sensitivity and precision. All four Soldanella species investigated contained the three saponins. The lowest total level of the three saponins (1.09%) was observed in S. montana leaves while the highest saponin content (5.14%) was determined in S. alpina roots. The detection of saponins within the genus Soldanella is an indication that further phytochemical examination of this genus may reveal more secondary metabolites of interest. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Neutron reflectivity measurement of protein A-antibody complex at the solid-liquid interface.

    PubMed

    Mazzer, Alice R; Clifton, Luke A; Perevozchikova, Tatiana; Butler, Paul D; Roberts, Christopher J; Bracewell, Daniel G

    2017-05-26

    Chromatography is a ubiquitous unit operation in the purification of biopharmaceuticals yet few studies have addressed the biophysical characterisation of proteins at the solution-resin interface. Chromatography and other adsorption and desorption processes have been shown to induce protein aggregation which is undesirable in biopharmaceutical products. In order to advance understanding of how adsorption processes might impact protein stability, neutron reflectivity was used to characterise the structure of adsorbed immunoglobulin G (IgG) on model surfaces. In the first model system, IgG was adsorbed directly to silica and demonstrated a side-on orientation with high surface contact. A maximum dimension of 60Å in the surface normal direction and high density surface coverage were observed under pH 4.1 conditions. In chromatography buffers, pH was found to influence IgG packing density and orientation at the solid-liquid interface. In the second model system, which was designed to mimic an affinity chromatography surface, protein A was attached to a silica surface to produce a configuration representative of a porous glass chromatography resin. Interfacial structure was probed during sequential stages from ligand attachment, through to IgG binding and elution. Adsorbed IgG structures extended up to 250Å away from the surface and showed dependence on surface blocking strategies. The data was suggestive of two IgG molecules bound to protein A with a somewhat skewed orientation and close proximity to the silica surface. The findings provide insight into the orientation of adsorbed antibody structures under conditions encountered during chromatographic separations. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  11. Successful pregnancy after spermatid injection.

    PubMed

    Bernabeu, R; Cremades, N; Takahashi, K; Sousa, M

    1998-07-01

    We present nine cases of spermatid intracytoplasmic injection for the treatment of non-obstructive azoospermia. In eight cases, no elongated spermatids or spermatozoa were found in previous spermiograms or testicular biopsies. In these patients, treatment was performed using ejaculated (n = 6) and testicular (n = 2) retrieved round spermatids (Sa type). In cases where ejaculated round spermatids were used, they were isolated on the day before oocyte retrieval and left in culture for 24 h before intracytoplasmic sperm injection (ICSI). No pregnancy was obtained in either group, although culturing seemed to increase the fertilization rate. In one other case, elongated spermatids were observed in the previous spermiogram and thus a normal ICSI procedure was scheduled. However, on the day of oocyte retrieval, no spermatids could be recovered from fresh sequential ejaculates, and a testicular open biopsy was then performed. Both round and elongated spermatids were found in the testicular tissue, but only the more mature germinal cells (Sb2) were injected. From this case, a normal pregnancy was obtained which resulted in the birth by Caesarean section at 37 weeks of gestation of a normal healthy baby girl, weighing 2700 g.

  12. Development of a sensitive and rapid method for rifampicin impurity analysis using supercritical fluid chromatography.

    PubMed

    Li, Wei; Wang, Jun; Yan, Zheng-Yu

    2015-10-10

    A novel simple, fast and efficient supercritical fluid chromatography (SFC) method was developed and compared with RPLC method for the separation and determination of impurities in rifampicin. The separation was performed using a packed diol column and a mobile phase B (modifier) consisting of methanol with 0.1% ammonium formate (w/v) and 2% water (v/v). Overall satisfactory resolutions and peak shapes for rifampicin quinone (RQ), rifampicin (RF), rifamycin SV (RSV), rifampicin N-oxide (RNO) and 3-formylrifamycinSV (3-FR) were obtained by optimization of the chromatography system. With gradient elution of mobile phase, all of the impurities and the active were separated within 4 min. Taking full advantage of features of SFC (such as particular selectivity, non-sloping baseline in gradient elution, and without injection solvent effects), the method was successfully used for determination of impurities in rifampicin, with more impurity peaks detected, better resolution achieved and much less analysis time needed compared with conventional reversed-phase liquid chromatography (RPLC) methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Simultaneous achiral-chiral analysis of pharmaceutical compounds using two-dimensional reversed phase liquid chromatography-supercritical fluid chromatography.

    PubMed

    Venkatramani, C J; Al-Sayah, Mohammad; Li, Guannan; Goel, Meenakshi; Girotti, James; Zang, Lisa; Wigman, Larry; Yehl, Peter; Chetwyn, Nik

    2016-02-01

    A new interface was designed to enable the coupling of reversed phase liquid chromatography (RPLC) and supercritical fluid chromatography (SFC). This online two-dimensional chromatographic system utilizing RPLC in the first dimension and SFC in the second was developed to achieve simultaneous achiral and chiral analysis of pharmaceutical compounds. The interface consists of an eight-port, dual-position switching valve with small volume C-18 trapping columns. The peaks of interest eluting from the first RPLC dimension column were effectively focused as sharp concentration pulses on small volume C-18 trapping column/s and then injected onto the second dimension SFC column. The first dimension RPLC separation provides the achiral purity result, and the second dimension SFC separation provides the chiral purity result (enantiomeric excess). The results are quantitative enabling simultaneous achiral, chiral analysis of compounds. The interface design and proof of concept demonstration are presented. Additionally, comparative studies to conventional SFC and case studies of the applications of 2D LC-SFC in pharmaceutical analysis is presented. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Establishment of A431 cell membrane chromatography-RPLC method for screening target components from Radix Caulophylli.

    PubMed

    Hou, Xiaofang; Wang, Sicen; Hou, Jingjing; He, Langchong

    2011-03-01

    We describe here an analytical method of A431 cell membrane chromatography (A431/CMC) (CMC, cell membrane chromatography) combined with RPLC for recognition, separation, and identification of target components from traditional Chinese medicines (TCMs) Radix Caulophylli. The A431 cells with high expressed epidermal growth factor receptor (EGFR) were used to prepare the stationary phase in the CMC model. Retention fractions on the A431-CMC model were collected using an automated fraction collection and injection module (FC/I). Each fraction was analyzed by RPLC under the optimized conditions. Gefitinib and erlotinib were used as standard compounds to investigate the suitability and reliability of the A431 cell membrane chromatography-RPLC method prior to screening target component from Radix Caulophylli total alkaloids. The results indicated that caulophine and taspine were the target component acting on the epidermal growth factor receptor. This method could be an efficient way in drug discovery using natural medicinal herbs as a source of novel compounds. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Determination of endocrine disrupting chemicals and antiretroviral compounds in surface water: A disposable sorptive sampler with comprehensive gas chromatography - Time-of-flight mass spectrometry and large volume injection with ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wooding, Madelien; Rohwer, Egmont R; Naudé, Yvette

    2017-05-05

    Many rural dwellers and inhabitants of informal settlements in South Africa are without access to treated water and collect untreated water from rivers and dams for personal use. Endocrine disrupting chemicals (EDCs) have been detected in surface water and wildlife of South Africa. EDCs are often present in complex environmental matrices at ultra-trace levels complicating detection thereof. We report a simplified multi-residue approach for the detection and quantification of EDCs, emerging EDCs, and antiretroviral drugs in surface water. A low cost (less than one US dollar), disposable, sorptive extraction sampler was prepared in-house. The disposable samplers consisted of polydimethylsiloxane (PDMS) tubing fashioned into a loop which was then placed in water samples to concentrate EDCs and emerging pollutants. The PDMS samplers were thermally desorbed directly in the inlet of a GC, thereby eliminating the need for expensive consumable cryogenics. Comprehensive gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was used for compound separation and identification. Linear retention indices of EDCs and emerging pollutants were determined on a proprietary Crossbond ® phase Rtx ® -CLPesticides II GC capillary column. In addition, large volume injection of surface water into an ultra-performance liquid chromatograph tandem mass spectrometer (UPLC-MS/MS) was used as complementary methodology for the detection of less volatile compounds. Large volume injection reduced tedious and costly sample preparation steps. Limits of detection for the GC method ranged from 1 to 98pg/l and for the LC method from 2 to 135ng/l. Known and emerging EDCs such as pharmaceuticals, personal care products and pesticides, as well as the antiretroviral compounds, efavirenz and nevirapine, were detected in surface water from South Africa at concentration levels ranging from 0.16ng/l to 227ng/l. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Lingzhi or Reishi Medicinal Mushroom, Ganoderma lucidum (Agaricomycetes), Inhibits Candida Biofilms: A Metabolomic Approach.

    PubMed

    Bhardwaj, Anuja; Gupta, Payal; Kumar, Navin; Mishra, Jigni; Kumar, Ajai; Rakhee, Rajput; Misra, Kshipra

    2017-01-01

    This article presents a comparative gas chromatography (GC)-mass spectrometry (MS)-based metabolomic analysis of mycelia and fruiting bodies of the medicinal mushroom Ganoderma lucidum. Three aqueous extracts-mycelia, fruiting bodies, and a mixture of them-and their sequential fractions (methanolic and ethyl acetate), prepared using an accelerated solvent extractor, were characterized by GC-MS to determine volatile organic compounds and by high-performance thin-layer chromatography to quantify ascorbic acid, a potent antioxidant. In addition, these extracts and fractions were assessed against Candida albicans and C. glabrata biofilms via the XTT reduction assay, and their antioxidant potential was evaluated. Application of chemometrics (hierarchical cluster analysis and principal component analysis) to GC data revealed variability in volatile organic compound profiles among G. lucidum extracts and fractions. The mycelial aqueous extract demonstrated higher anti-Candida activity and ascorbic acid content among all the extracts and fractions. Thus, this study illustrates the preventive effect of G. lucidum against C. albicans and C. glabrata biofilms along with its nutritional value.

  17. [Isolation and purification of seven catechin compounds from fresh tea leaves by semi-preparative liquid chromatography].

    PubMed

    Gong, Zhihong; Chen, Si; Gao, Jiangtao; Li, Meihong; Wang, Xiaxia; Lin, Jun; Yu, Xiaomin

    2017-11-08

    An effective and simple method was established to simultaneously purify seven tea catechins (gallocatechin (GC), epigallocatechin (EGC), catechin (C), epigallocatechin-3- O -gallate (EGCG), epicatechin (EC), epigallocatechin-3- O -(3- O -methyl)-gallate (EGCG3"Me) and epicatechin-3- O -gallate (ECG)) from fresh tea leaves by semi-preparative high performance liquid chromatography (HPLC). Fresh leaves of Tieguanyin tea were successively extracted with methanol and chloroform. Then crude catechins were precipitated from the aqueous fraction of chloroform extraction by adding lead subacetate. Crude catechins were used for the isolation of the seven target catechin compounds by semi-preparative HPLC. Methanol-water and acetonitrile-water were sequentially used as mobile phases. After two rounds of semi-preparative HPLC, all target compounds were achieved with high purities (>90%). The proposed method was tested on two additional tea cultivars and showed similar results. This method demonstrated a simple and efficient strategy based on solvent extraction, ion precipitation and semi-preparative HPLC for the preparation of multiple catechins from tea leaves.

  18. Highly informative multiclass profiling of lipids by ultra-high performance liquid chromatography - Low resolution (quadrupole) mass spectrometry by using electrospray ionization and atmospheric pressure chemical ionization interfaces.

    PubMed

    Beccaria, Marco; Inferrera, Veronica; Rigano, Francesca; Gorynski, Krzysztof; Purcaro, Giorgia; Pawliszyn, Janusz; Dugo, Paola; Mondello, Luigi

    2017-08-04

    A simple, fast, and versatile method, using an ultra-high performance liquid chromatography system coupled with a low resolution (single quadrupole) mass spectrometer was optimized to perform multiclass lipid profiling of human plasma. Particular attention was made to develop a method suitable for both electrospray ionization and atmospheric pressure chemical ionization interfaces (sequentially in positive- and negative-ion mode), without any modification of the chromatographic conditions (mobile phase, flow-rate, gradient, etc.). Emphasis was given to the extrapolation of the structural information based on the fragmentation pattern obtained using atmospheric pressure chemical ionization interface, under each different ionization condition, highlighting the complementary information obtained using the electrospray ionization interface, of support for related molecule ions identification. Furthermore, mass spectra of phosphatidylserine and phosphatidylinositol obtained using the atmospheric pressure chemical ionization interface are reported and discussed for the first time. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.

    PubMed

    Nagatsu, T; Oka, K; Kato, T

    1979-07-21

    A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.

  20. Structural features and antitumor activity of a purified polysaccharide extracted from Sargassum horneri.

    PubMed

    Shao, Ping; Liu, Jia; Chen, Xiaoxiao; Fang, Zhongxiang; Sun, Peilong

    2015-02-01

    A polysaccharide fraction (SHPSA) was obtained from Sargassum horneri by hot-water extraction and sequential purification of anion-exchange chromatography and gel-filtration chromatography. SHPSA was found to be a neutral polysaccharide fraction with an average molecular weight of 5.78×10(5) Da and composed of T-D-Glcp, 1,3-D-Glcp, 1,6-D-Glcp and 1,3,6-D-Glcp in a molar percentage of 1.00:4.17:1.17:0.89, respectively. Based on the results from chemical analysis, NMR, and SHPSA was determined to be a glucan with β-(1→6) side chains linked to a β-(1→3) backbone with relatively few branch points. Moreover, SHPSA could inhibit the growth of human colon cancer DLD cells in a dose-dependent manner by inducing the apoptosis of DLD cells. So, SHPSA was promising for future use as a natural antitumor agent. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Purification and characterization of a strong fibrinolytic enzyme (nattokinase) in the vegetable cheese natto, a popular soybean fermented food in Japan.

    PubMed

    Fujita, M; Nomura, K; Hong, K; Ito, Y; Asada, A; Nishimuro, S

    1993-12-30

    A strong fibrinolytic enzyme (nattokinase) was purified from the vegetable cheese natto. Nattokinase was extracted from natto with saline and isolated by sequential use of hydrophobic chromatography on Butyl-Toyopearl, ion-exchange chromatography on CM-Toyopearl, and gel-filtration on Sephadex G-50. The isolated protein gave a single sharp band on SDS-PAGE either before or after reduction. The sequence, as determined by automated Edman degradation of the uncleaved molecule and its enzymatically derived peptide, consisted of a total 275 amino acid residues (M.W = 27,728) and exhibited a high homology with the subtilisins. The purified nattokinase digested not only fibrin but also several synthetic substrates. Among the synthetic substrates, the most sensitive substrate was Suc-Ala-Ala-Pro-Phe-pNA for subtilisin. PMSF inhibited both the fibrinolytic activity and the amidolytic activity. The results indicate that nattokinase is a subtilisin-like serine protease.

  2. Purification and characterization of a novel lignin peroxidase from white-rot fungus Phanerochaete sordida YK-624.

    PubMed

    Sugiura, Mutsumi; Hirai, Hirofumi; Nishida, Tomoaki

    2003-07-29

    We characterized kinetics and substrate oxidation of a novel lignin peroxidase (YK-LiP) isolated from white-rot fungus Phanerochaete sordida YK-624. YK-LiP enzyme was identified and purified to homogeneity by anion-exchange chromatography and gel permeation chromatography. The molecular mass of YK-LiP was approximately 50 kDa, and the absorption spectrum of YK-LiP was almost the same as that of the LiP (Pc-LiP) from Phanerochaete chrysosporium. Steady-state kinetics of veratryl alcohol oxidation by YK-LiP (unlike that by Pc-LiP) revealed a bi-reactant sequential mechanism, although reactivity of YK-LiP to various monomeric substituted aromatic compounds was similar to that of Pc-LiP. Degradation of dimeric lignin model compounds was more effective by YK-LiP than by Pc-LiP, and the oxidation rate of sinapyl alcohol oligomer by YK-LiP was much faster than that by Pc-LiP.

  3. Isolation and characterization of a new zinc-binding protein from albacore tuna plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyke, B.; Hegenauer, J.; Saltman, P.

    1987-06-02

    The protein responsible for sequestering high levels of zinc in the plasma of the albacore tuna (Thunnus alalunga) has been isolated by sequential chromatography. The glycoprotein has a molecular weight of 66,000. Approximately 8.2% of its amino acid residues are histidines. Equilibrium dialysis experiments show it to bind 3 mol of zinc/mol of protein. The stoichiometric constant for the association of zinc with a binding site containing three histidines was determined to be 10/sup 9.4/. This protein is different from albumin and represents a previously uncharacterized zinc transport protein.

  4. Method for gasification of deep, thin coal seams. [DOE patent

    DOEpatents

    Gregg, D.W.

    1980-08-29

    A method of gasification of coal in deep, thin seams by using controlled bending subsidence to confine gas flow to a region close to the unconsumed coal face is given. The injection point is moved sequentially around the perimeter of a coal removal area from a production well to sweep out the area to cause the controlled bending subsidence. The injection holes are drilled vertically into the coal seam through the overburden or horizontally into the seam from an exposed coal face. The method is particularly applicable to deep, thin seams found in the eastern United States and at abandoned strip mines where thin seams were surface mined into a hillside or down a modest dip until the overburden became too thick for further mining.

  5. Method for gasification of deep, thin coal seams

    DOEpatents

    Gregg, David W.

    1982-01-01

    A method of gasification of coal in deep, thin seams by using controlled bending subsidence to confine gas flow to a region close to the unconsumed coal face. The injection point is moved sequentially around the perimeter of a coal removal area from a production well to sweep out the area to cause the controlled bending subsidence. The injection holes are drilled vertically into the coal seam through the overburden or horizontally into the seam from an exposed coal face. The method is particularly applicable to deep, thin seams found in the eastern United States and at abandoned strip mines where thin seams were surface mined into a hillside or down a modest dip until the overburden became too thick for further mining.

  6. Drug injection into fat tissue with a laser based microjet injector

    NASA Astrophysics Data System (ADS)

    Han, Tae-hee; Hah, Jung-moo; Yoh, Jack J.

    2011-05-01

    We have investigated a new micro drug jet injector using laser pulse energy. An infrared laser beam of high energy (˜3 J/pulse) is focused inside a driving fluid in a small chamber. The pulse then induces various energy releasing processes, and generates fast microjets through a micronozzle. The elastic membrane of this system plays an important role in transferring mechanical pressure and protecting drug from heat release. In this paper, we offer the sequential images of microjet generation taken by a high speed camera as an evidence of the multiple injections via single pulse. Furthermore, we test the proposed system to penetrate soft animal tissues in order to evaluate its feasibility as an advanced transdermal drug delivery method.

  7. Identification of a major 50-kDa molecular weight human B-cell growth factor with Tac antigen-inducing activity on B cells.

    PubMed

    Kawano, M; Matsushima, K; Oppenheim, J J

    1987-08-01

    A bioassay was developed using human small B cells adherent to anti-human IgM (anti-mu)-coated wells. These B cells were stimulated to proliferate by culture supernatants of concanavalin A (Con A)-activated human peripheral blood lymphocytes (Con A Sup) even in the presence of high concentrations of anti-mu coated on assay wells. Human B-cell growth factor (BCGF) activities were partially purified from Con A Sup. Preparative chromatography (Sephacryl S-200 and isoelectrofocusing) yielded a major peak of BCGF activity for B cells adherent to anti-mu-coated wells with a molecular weight of 50,000 (50 kDa) and a pI 7.6. The 50-kDa BCGF was further purified by sequential chromatography using DEAE-Sephacel, CM-Sepharose, Sephacryl S-200, CM-high performance liquid chromatography (HPLC), and hydroxyapatite (HA)-HPLC. The HA-HPLC-purified 50-kDa BCGF was free of interleukin-1 (IL-1), interleukin-2 (IL-2), and interferon activities, but could support growth of BCL1 cells, similar to BCGF-II. Neither IL-1 nor interferon-gamma had any growth-stimulating effect in our B-cell proliferation assay with or without BCGF in Iscove's synthetic assay medium. BCGF-induced proliferation of B cells adherent to anti-mu-coated wells could be markedly augmented by the simultaneous or sequential addition of recombinant human IL-2 (rIL-2). When cultured for 3 days with 50-kDa BCGF, about 40% of B cells adherent to anti-mu-coated wells expressed Tac antigen, and monoclonal anti-Tac antibody inhibited rIL-2 enhancement of proliferation of 50-kDa BCGF-preactivated B cells. In addition, 50-kDa BCGF could induce Tac antigen on an Epstein-Barr virus-transformed B-cell line (ORSON) in the presence of a suboptimal dose of phorbol myristate acetate (PMA) and also on a natural killer-like cell line (YT cells). We have therefore identified a major 50-kDa BCGF activity with Tac antigen-inducing activity that also has a synergistic effect with IL-2 on normal B-cell proliferation.

  8. Small scale separation of isoxazole structurally related analogues by chiral supercritical fluid chromatography.

    PubMed

    Zehani, Yasmine; Lemaire, Lucas; Millet, Regis; Lipka, Emmanuelle

    2017-07-07

    Chromatographic preparative enantioseparation is now the preferred method to obtain milligram amounts of pure enantiomers in the first step of the development of a therapeutic molecule. Supercritical fluid chromatography has many advantages over liquid chromatography and was therefore chosen for the small scale enantioseparation of four original 3-carboxamido-5-aryl isoxazole molecules, ligands of the CB2 cannabinoid receptors. The preparation of about 10mg of each of the eight enantiomers was achieved successfully on a Chiralpak ® AD-H (tris-3,5-dimethylphenylcarbamate of amylose) polysaccharide based stationary phase with various percentages of ethanol as a co-solvent, through mixed-stream injections and touching-band approach. For the all compounds, no peak distortion is observed during the volume overloading, in spite of the injection mode. Production rate (mgmin -1 ), productivity (kilogram of racemate separated per kilogram of CSP per day (kkd)) and solvent usage were found higher and environmental factors (E Factor) were found lower for compounds 1 and 3. The yields of each purified enantiomer were comprised between 60 and 94%. In order to improve the limit of detection calculated with the diode array detector, the hyphenation with an evaporating light scattering detector was explored and a factor of ten was won. Lastely, the enantiomeric excess and achiral purity of each of the eight individual enantiomer generated was determined and found higher than 98%. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Preparation of fatty acid methyl esters for gas-liquid chromatography[S

    PubMed Central

    Ichihara, Ken'ichi; Fukubayashi, Yumeto

    2010-01-01

    A convenient method using commercial aqueous concentrated HCl (conc. HCl; 35%, w/w) as an acid catalyst was developed for preparation of fatty acid methyl esters (FAMEs) from sterol esters, triacylglycerols, phospholipids, and FFAs for gas-liquid chromatography (GC). An 8% (w/v) solution of HCl in methanol/water (85:15, v/v) was prepared by diluting 9.7 ml of conc. HCl with 41.5 ml of methanol. Toluene (0.2 ml), methanol (1.5 ml), and the 8% HCl solution (0.3 ml) were added sequentially to the lipid sample. The final HCl concentration was 1.2% (w/v). This solution (2 ml) was incubated at 45°C overnight or heated at 100°C for 1–1.5 h. The amount of FFA formed in the presence of water derived from conc. HCl was estimated to be <1.4%. The yields of FAMEs were >96% for the above lipid classes and were the same as or better than those obtained by saponification/methylation or by acid-catalyzed methanolysis/methylation using commercial anhydrous HCl/methanol. The method developed here could be successfully applied to fatty acid analysis of various lipid samples, including fish oils, vegetable oils, and blood lipids by GC. PMID:19759389

  10. Acaricidal and repellent effects of Cnidium officinale-derived material against Dermanyssus gallinae (Acari: Dermanyssidae).

    PubMed

    Kim, Hyun Kyung; Lee, Seung Ju; Hwang, Bang-Yeon; Yoon, Jong Ung; Kim, Gil-Hah

    2018-04-01

    The acaricidal activity of a methanolic extract and fractions from the rhizome of Cnidium officinale against Dermanyssus gallinae adults was investigated. The C. officinale methanolic extract exhibited 100% acaricidal activity after 48 h of treatment at a dose of 4000 ppm. The acaricidal constituents of the plant were sequentially partitioned with several solvents and then purified using silica gel column chromatography and high-performance liquid chromatography. Gas chromatography-mass spectrometry and nuclear magnetic resonance spectroscopy revealed (Z)-ligustilide as a constituent of C. officinale. Acaricidal activity was examined in three experimental tests (spray, fumigation and contact), with the spraying method being the most effective. The methanolic extract of C. officinale showed both contact and fumigant activities, though only fumigant activity was observed with (Z)-ligustilide. The fumigant effects of the methanolic extract and (Z)-ligustilide caused 86.5 and 62.6% mortality, respectively, of D. gallinae adults at 48 h. Among (Z)-ligustilide, acaricides (bifenthrin, cypermethrin and spinosad) and butylidenephthalide, bifenthrin displayed the highest acaricidal activity, and the activity of butylidenephthalide was 2.3-fold higher than that of (Z)-ligustilide. These results suggest that C. officinale-derived material can be used for the development of a control agent for D. gallinae.

  11. Two-dimensional liquid chromatography consisting of twelve second-dimension columns for comprehensive analysis of intact proteins.

    PubMed

    Ren, Jiangtao; Beckner, Matthew A; Lynch, Kyle B; Chen, Huang; Zhu, Zaifang; Yang, Yu; Chen, Apeng; Qiao, Zhenzhen; Liu, Shaorong; Lu, Joann J

    2018-05-15

    A comprehensive two-dimensional liquid chromatography (LCxLC) system consisting of twelve columns in the second dimension was developed for comprehensive analysis of intact proteins in complex biological samples. The system consisted of an ion-exchange column in the first dimension and the twelve reverse-phase columns in the second dimension; all thirteen columns were monolithic and prepared inside 250 µm i.d. capillaries. These columns were assembled together through the use of three valves and an innovative configuration. The effluent from the first dimension was continuously fractionated and sequentially transferred into the twelve second-dimension columns, while the second-dimension separations were carried out in a series of batches (six columns per batch). This LCxLC system was tested first using standard proteins followed by real-world samples from E. coli. Baseline separation was observed for eleven standard proteins and hundreds of peaks were observed for the real-world sample analysis. Two-dimensional liquid chromatography, often considered as an effective tool for mapping proteins, is seen as laborious and time-consuming when configured offline. Our online LCxLC system with increased second-dimension columns promises to provide a solution to overcome these hindrances. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis.

    PubMed

    Quintana, José Benito; Miró, Manuel; Estela, José Manuel; Cerdà, Víctor

    2006-04-15

    In this paper, the third generation of flow injection analysis, also named the lab-on-valve (LOV) approach, is proposed for the first time as a front end to high-performance liquid chromatography (HPLC) for on-line solid-phase extraction (SPE) sample processing by exploiting the bead injection (BI) concept. The proposed microanalytical system based on discontinuous programmable flow features automated packing (and withdrawal after single use) of a small amount of sorbent (<5 mg) into the microconduits of the flow network and quantitative elution of sorbed species into a narrow band (150 microL of 95% MeOH). The hyphenation of multisyringe flow injection analysis (MSFIA) with BI-LOV prior to HPLC analysis is utilized for on-line postextraction treatment to ensure chemical compatibility between the eluate medium and the initial HPLC gradient conditions. This circumvents the band-broadening effect commonly observed in conventional on-line SPE-based sample processors due to the low eluting strength of the mobile phase. The potential of the novel MSFI-BI-LOV hyphenation for on-line handling of complex environmental and biological samples prior to reversed-phase chromatographic separations was assessed for the expeditious determination of five acidic pharmaceutical residues (viz., ketoprofen, naproxen, bezafibrate, diclofenac, and ibuprofen) and one metabolite (viz., salicylic acid) in surface water, urban wastewater, and urine. To this end, the copolymeric divinylbenzene-co-n-vinylpyrrolidone beads (Oasis HLB) were utilized as renewable sorptive entities in the micromachined unit. The automated analytical method features relative recovery percentages of >88%, limits of detection within the range 0.02-0.67 ng mL(-1), and coefficients of variation <11% for the column renewable mode and gives rise to a drastic reduction in operation costs ( approximately 25-fold) as compared to on-line column switching systems.

  13. Isolation and identification of human metabolites from a novel anti-tumor candidate drug 5-chlorogenic acid injection by HPLC-HRMS/MSn and HPLC-SPE-NMR.

    PubMed

    Ren, Tiankun; Wang, Yanan; Wang, Caihong; Zhang, Mengtian; Huang, Wang; Jiang, Jiandong; Li, Wenbin; Zhang, Jinlan

    2017-12-01

    A novel anti-tumor candidate drug, 5-chlorogenic acid (5-CQA) injection, was used for the treatment of malignant glioma in clinical trial (phase I) in China. The isolation and identification of the metabolites of 5-CQA injection in humans were investigated in the present study. Urine and feces samples obtained after intramuscular administration of 5-CQA injection to healthy adults have been analyzed by high-performance liquid chromatography coupled with high-resolution mass and multiple-stage mass spectrometry (HPLC-HRMS/MS n ). No metabolite was detected in human feces; however, in human urine, a total of six metabolites were identified including isomerized 5-CQA (P1 and P2), hydrolyzed 5-CQA (M1and M2), and methylated 5-CQA (M3 and M4). Among them, M3 and M4 were the main metabolites and target analytes for human mass balance study. Additionally, the structure of M3 and M4 was characterized by high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance (HPLC-SPE-NMR), and the results demonstrated that the methoxy group of M3 and M4 was exclusively attributed to C-3' and C-4', respectively. Due to the unavailability of commercial reference, the pure products of M3 and M4 were synthesized by 5-CQA methylation and followed by isolation and purification. Moreover, the potential activity of M3 and M4 on malignant glioma was predicted using a reverse molecular docking analysis on eight malignant glioma-related pathways. The results showed that M3 and M4 had various interactions against malignant glioma-related targets. Our study provides an insight into the metabolism of 5-CQA injection in humans and supports the clinical human mass balance study. Graphical abstract ᅟ.

  14. Stability of Dalteparin 1,000 Unit/mL in 0.9% Sodium Chloride for Injection in Polypropylene Syringes.

    PubMed

    Kirkham, Kylian; Munson, Jessica M; McCluskey, Susan V; Graner, Kevin K

    2017-01-01

    The stability of dalteparin 1,000 units/mL in 0.9% sodium chloride for injection stored in polypropylene syringes under refrigeration was examined. Dalteparin 1,000-units/mL syringes were prepared by adding 9 mL of 0.9% sodium chloride for injection to 1 mL of dalteparin sodium 10,000 unit/mL from commercial single-use syringes. Compounded solutions in 0.5-mL aliquots were transferred to 1-mL polypropylene syringes and sealed with a Luer lock tip cap and stored at refrigerated temperatures (2°C to 8°C) with ambient fluorescent light exposure. Syringes from three batches of dalteparin 1,000 units/mL were potency tested in duplicate by a stability-indicating high-performance liquid chromatography assay using a 0.5-mL sample at specified intervals. Visual and pH testing were performed on each batch. Samples were visually inspected for container integrity, color, and clarity. Samples for pH testing were prepared using a 1:1 dilution of dalteparin 1,000 units/mL in sterile water for injection and underwent duplicate analysis at each time point. High-performance liquid chromatography analyses showed a remaining percent of the initial dalteparin content at day 30 of 94.88% ± 2.11%. Samples remained colorless and clear with no signs of container compromise and no visual particulate matter at each time point. Throughout the 30-day study period, pH values remained within 0.3-pH units from the initial value of 5.84. Dalteparin 1,000 unit/mL in 0.9% sodium chloride for injection, packaged in 1-mL polypropylene syringes was stable for at least 30 days while stored at refrigerated conditions with ambient fluorescent light exposure. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  15. A systematic investigation of sample diluents in modern supercritical fluid chromatography.

    PubMed

    Desfontaine, Vincent; Tarafder, Abhijit; Hill, Jason; Fairchild, Jacob; Grand-Guillaume Perrenoud, Alexandre; Veuthey, Jean-Luc; Guillarme, Davy

    2017-08-18

    This paper focuses on the possibility to inject large volumes (up to 10μL) in ultra-high performance supercritical fluid chromatography (UHPSFC) under generic gradient conditions. Several injection and method parameters have been individually evaluated (i.e. analyte concentration, injection volume, initial percentage of co-solvent in the gradient, nature of the weak needle wash solvent, nature of the sample diluent, nature of the column and of the analyte). The most critical parameters were further investigated using in a multivariate approach. The overall results suggested that several aprotic solvents including methyl tert-butyl ether (MTBE), dichloromethane, acetonitrile or cyclopentyl methyl ether (CPME) were well adapted for the injection of large volume in UHPSFC, while MeOH was generally the worst alternative. However, the nature of the stationary phase also had a strong impact and some of these diluents did not perform equally on each column. This was due to the existence of a competition in the adsorption of the analyte and the diluent on the stationary phase. This observation introduced the idea that the sample diluent should not only be chosen according to the analyte but also to the column chemistry to limit the interactions between the diluent and the ligands. Other important characteristics of the "ideal" SFC sample diluent were finally highlighted. Aprotic solvents with low viscosity are preferable to avoid strong solvent effects and viscous fingering, respectively. In the end, the authors suggest that the choice of the sample diluent should be part of the method development, as a function of the analyte and the selected stationary phase. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. [Detection of rifampicin concentration in cerebrospinal fluid by online enrichment and restricted-access media coupled with high-performance liquid chromatography].

    PubMed

    Yang, Xiaoping; Zhang, Xiaohui; Huang, Yanping; Wang, Rong; Xia, Hua; Li, Wenbin; Guo, YouMin

    2015-11-01

    To establish a method for detecting rifampicin in human cerebrospinal fluid (CSF) with restricted access media coupled with high-performance liquid chromatography that allows online direct sample injection and enrichment. We used the column of restricted access media as the pre-treatment column and a C18 column as the analytical column. The mobile phase of pre-treatment column was water-methanol (95:5,V/V) and the flow rate was 1 mL/min; the mobile phase of the analytical column was methanol-acetonitrile-10 mmol/L ammonuium acetate (volume ratio of 60:5:35). The detection wavelength was 254 nm and the column temperature was set at 25 degrees celsius;. For an injection volume of 100 µL, the peak area of rifampicin was 5.33 times that for an injection volume of 20 µL, and the limit of detection was effectively improved. The calibration curve showed an excellent linear relationship (r=0.9997) between rifampicin concentrations and peak areas within the concentration range of 0.25 to 8 µg/mL in CSF. The limits of detection and quantification was 0.07 µg/mL and 0.25 µg/mL, respecetively, with intra-day and inter-day assay precisions and relative standard deviation (RSD%) all below 5%. The recoveries of rifampicin at 3 blank spiked levels (low, medium, and high) ranged from 87.69% to 102.11%. In patients taking oral rifampicin at the dose of 10 mg/kg, the average rifampicin concentration was 0.29 in the CSF at 2 h after medication. The method we established is simple and fast for detecting rifampicin in CSF and allows direct online injection and enrichment with good detection precisions and accuracies.

  17. Rapid and sensitive liquid chromatography-tandem mass spectrometric method for the quantitative determination of potentially harmful substance 5,5'-oxydimethylenebis (2-furfural) in traditional Chinese medicine injections.

    PubMed

    Zang, Qingce; Gao, Yang; Huang, Luojiao; He, Jiuming; Lin, Sheng; Jin, Hongtao; Zhang, Ruiping; Abliz, Zeper

    2018-03-01

    With the rapid development and wide application of traditional Chinese medicine injection (TCMI), a number of adverse events of some TCMIs have incessantly been reported and have drawn broad attention in recent years. Establishing effective and practical analytical methods for safety evaluation and quality control of TCMI can help to improve the safety of TCMIs in clinical applications. In this study, a sensitive and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and validated for the quantitative determination of potentially harmful substance 5,5'-oxydimethylenebis (2-furfural, OMBF) in TCMI samples. Chromatographic separation was performed on a C18 reversed-phase column (150 mm × 2.1 mm, 5 µm) by gradient elution, using methanol-water containing 0.1% formic acid as mobile phase at the flow rate of 0.3 mL/min. MS/MS detection was performed on a triple quadrupole mass spectrometer with positive electrospray ionization in the multiple reaction-monitoring mode. The method was sensitive with a limit of quantification of 0.3 ng/mL and linear over the range of 0.3-30 ng/mL ( r =0.9998). Intra- and inter-day precision for analyte was <9.52% RSD with recoveries in the range 88.0-109.67% at three concentration levels. The validated method was successfully applied to quantitatively determine the compound OMBF in TCMIs and glucose injections. Our study indicates that this method is simple, sensitive, practicable and reliable, and could be applied for safety evaluation and quality control of TCMIs and glucose injections.

  18. Rapid and sensitive screening and selective quantification of antibiotics in human urine by two-dimensional ultraperformance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    PubMed

    Wang, He-Xing; Wang, Bin; Zhou, Ying; Jiang, Qing-Wu

    2014-12-01

    A rapid and sensitive method for the screening and selective quantification of antibiotics in urine by two-dimensional ultraperformance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry was developed. This method allowed the injection of 200 μL urine extract. The 200-μL injection volume used in this method increased the absolute sensitivity for target antibiotics in solvent by an average 13.3 times, with a range from 8.4 to 28.5 times, compared with the 10-μL conventional injection volume. A 96-well solid phase extraction procedure was established to eliminate the contamination on the chromatographic column resulting from the large-volume injection and increase the throughput of sample preparation. Fourteen target antibiotics from six common categories (β-lactams, quinolones, tetracyclines, macrolides, sulfonamides, and chloramphenicols) were selected as model compounds, and a database containing an additional 74 antibiotics was compiled for posttarget screening. The limit of detection of the target antibiotics, defined as a signal-to-noise ratio of 3, ranged from 0.04 to 1.99 ng/mL. The mean interday recoveries ranged between 79.6 and 121.3 %, with a relative standard deviation from 2.9 to 18.3 % at three spiking levels of 20 ng/mL, 50 ng/mL, and 100 ng/mL. This method was successfully applied in 60 real urine samples from schoolchildren aged 8-11 years, and four target antibiotics (azithromycin, sulfadiazine, trimethoprim, and oxytetracycline) and two posttarget antibiotics (sulfadimidine and cefaclor) were found in the urine samples. This method can be used as a large-scale biomonitoring tool for exposure of the human population to antibiotics.

  19. Anandamide enhances extracellular levels of adenosine and induces sleep: an in vivo microdialysis study.

    PubMed

    Murillo-Rodriguez, Eric; Blanco-Centurion, Carlos; Sanchez, Cristina; Piomelli, Daniele; Shiromani, Priyattam J

    2003-12-15

    The principal component of marijuana, delta-9-tetrahydrocannabinol increases sleep in humans. Endogenous cannabinoids, such as N-arachidonoylethanolamine (anandamide), also increase sleep. However, the mechanism by which these molecules promote sleep is not known but might involve a sleep-inducing molecule such as adenosine. Microdialysis samples were collected from the basal forebrain in order to detect levels of adenosine before and after injection of anandamide. Rats were implanted for sleep studies, and a cannula was placed in the basal forebrain to collect microdialysis samples. Samples were analyzed using high-performance liquid chromatography. Basic neuroscience research laboratory. Three-month-old male F344 rats. At the start of the lights-on period, animals received systemic injections of dimethyl sulfoxide (vehicle), anandamide, SR141716A (cannabinoid receptor 1 [CB1] antagonist), or SR141716A and anandamide. One hour after injections, microdialysis samples were collected (5 microL) from the basal forebrain every hour over a 20-minute period for 5 hours. The samples were immediately analyzed via high-performance liquid chromatography for adenosine levels. Sleep was also recorded continuously over the same period. Anandamide increased adenosine levels compared to vehicle controls with the peak levels being reached during the third hour after drug injection. There was a significant increase in slow-wave sleep during the third hour. The induction in sleep and the rise in adenosine were blocked by the CB1-receptor antagonist, SR141716A. Anandamide increased adenosine levels in the basal forebrain and also increased sleep. The soporific effects of anandamide were mediated by the CB1 receptor, since the effects were blocked by the CB1-receptor antagonist. These findings identify a potential therapeutic use of endocannabinoids to induce sleep in conditions where sleep may be severely attenuated.

  20. Simultaneous determination of Cr(III) and Cr(VI) in tannery wastewater using low pressure ion chromatography combined with flow injection spectrophotometry

    NASA Astrophysics Data System (ADS)

    Chen, Shujuan; Zhang, Xinshen; Yu, Lingyun; Wang, Li; Li, Hui

    2012-03-01

    Trivalent and hexavalent chromium have been successfully separated and determined using low pressure ion chromatography combined with flow injection spectrophotometric analysis (LPIC-FIA). A column packed with crosslinking starch microspheres was used for on-line separation of Cr(III) from Cr(VI) in a flow-injection system because of its absorptive effect on Cr(III). To determine the concentration of Cr(III) and Cr(VI) in samples, we used 3.0 mmol/L nitric acid to elute adsorbed Cr(III) from the column and then used ceric sulfate-sulfuric acid as oxidant to convert all Cr(III) into Cr(VI). Then, Cr(VI) directly came from the samples and Cr(VI) came from Cr(III) successively formed a amaranthine complex with diphenycarbazide and the complex shows a maximum absorption at 530 nm. Analytical parameters including the concentration of eluent and oxidant solution, oxidizing temperature, length of oxidizing reaction coil, reaction coil and injection coil, interfering effects, etc., were optimized. The limit of detection was 1.25 μg/L for Cr(VI) and 3.76 μg/L for Cr(III). The linear relationship between absorption with the concentration of Cr(VI) and Cr(III) was 0.001-1.000 mg/L and 0.030-1.000 mg/L with correlation coefficients of 0.9995 and 0.9994, respectively. The relative standard deviation of Cr(VI) and Cr(III) was 1.21% and 1.66%, respectively (n = 10). Major cations and anions did not show any interference. We validated this method through certified reference materials and through measuring the recovery in tannery wastewater.

  1. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    PubMed

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  2. [Studies on a sequential injection renewable surface reflectance spectrophotometric system using a microchip flow cell].

    PubMed

    Wang, Jian-ya; Fang, Zhao-lun

    2002-02-01

    A microchip flow cell was developed for flow injection renewable surface assay by reflectance spectrophotometry. The flow cell was coupled to a sequential injection system and optical fiber photometric detection system. The flow cell featured a three-layer structure. The flow channel was cut into a silicone rubber membrance which formed the middle layer, and a porous filter was inlayed across a widened section of the channel to trap microbeads introduced into the flow cell. The area of the detection window of the flow cell was approximately 3.6 mm2, the volume of the bead trapped in the flow cell was 2.2 microL, the depth of the bead layer was 600 microns. A multistrand bifurcated optical fiber was coupled with incident light, detector and flow cell. The chromogenic reaction of Cr(VI) with 1,5-diphenylcarbohydrazide (DPC) which was adsorbed on trapped Polysorb C-18 beads was used as a model reaction to optimize the flow cell design and the experimental system. The reflectance of the renewable reaction surface was monitored at 540 nm. With 100 microL sample loaded and 1.0 mL.min-1 carrier flow rate, the linear response range was 0-0.6 microgram.mL-1 Cr(VI). A detection limit (3 sigma) of 6 ng.mL-1, precision of 1.5% RSD(n = 11), and a throughput of 64 samples per hour were achieved. Considerations in system and flow cell design, the influence of depth of the bead layer, weight of beads used, and the flow rates of carrier stream on the performance were discussed.

  3. A flow system for the spectrophotometric determination of lead in different types of waters using ion-exchange for pre-concentration and elimination of interferences.

    PubMed

    Mesquita, Raquel B R; Fernandes, Sílvia M V; Rangel, António O S S

    2004-02-06

    A flow system for the spectrophotometric determination of lead in natural and waste waters is proposed. The determination is based on the colorimetric reaction between malachite green and iodide, followed by the formation of a ternary complex between those reagents and lead cations. The developed flow system includes a lead pre-concentration step in a column packed with a cationic resin (Chelex 100) operating in a sequential injection mode. To improve the mixture of sample and reagents, a flow injection approach was adopted for the colorimetric determination. This way a hybrid flow system, involving both sequential and flow injection concepts was designed. Another feature of the proposed system is the efficient elimination of major interferent species, such as cadmium and copper. The elimination of cadmium interference is obtained by complexing Cd(2+) with chloride and retaining the formed negatively charged complexes in an anionic resin, AG1 X-8. As for copper, with the presence of both ionic resins as well as the conditions for cadmium elimination, it no longer acts as an interferent. Different ranges of lead concentration (50-300 and 300-1000mugl(-1)) can be determined with minor changes in the controlling software, useful for application to both natural and waste waters. Therefore, a detection limit of 25mugl(-1) was achieved. Repeatability was evaluated from 10 consecutive determinations being the results better than 4%. The recoveries of lead spikes added to the samples ranged from 93 to 102%. The sampling frequency was 17 and 24 determinations per hour, for 50-300 and 300-1000mugl(-1) ranges, respectively.

  4. DETERMINATION OF PESTICIDES IN COMPOSITE DIETARY SAMPLES BY GAS CHROMATOGRAPHY/MASS SPECTROMETRY IN THE SELECTED ION MONITORING MODE USING A TEMPERATURE PROGRAMMABLE LARGE VOLUME INJECTOR WITH PRE-SEPARATION COLUMN

    EPA Science Inventory

    Use of a temperature-programmable pre-separation column in the gas chromatographic injection port permits determination of a wide range of semi-volatile pesticides including organochlorines, organophosphates, triazines, and anilines in fatty composite dietary samples while reduci...

  5. Simultaneous determination of the absolute configuration of twelve monosaccharide enantiomers from natural products in a single injection by UPLC-UV/MS method

    USDA-ARS?s Scientific Manuscript database

    In natural product chemistry, it is often crucial to determine sugar composition as well as the absolute configuration of each monosaccharide in glycosides. An ultra-performance liquid chromatography method using both photodiode array (PDA) and mass spectrometry detectors (UPLC-UV/MS) was developed....

  6. Measurement of Polycyclic Aromatic Hydrocarbons in Airborne Particulate Matter at Low Concentrations

    DTIC Science & Technology

    2012-03-01

    Soil & Water Colorimetric (diphenylcarbazide) 7199 Hexavalent Chromium by Ion Chromatography 218.6 Low level chelation & extraction NATTS...Hexane:Dichloromethane:Methanol Dionex ASE 200 Sample Concentration Evaporation in Ultrapure Nitrogen Stream Zymark Turbovap Solid Phase Extraction Supelco Custom...Glass Silica SPE Cartridge 1% Dichloromethane + 1% Acetone in Hexane GCMS Analysis Conventional Splitless Injection Selective Ion Monitoring

  7. Identification of a host compound and its practical applications: 4-allylanisole as a bark beetle repellent

    Treesearch

    J.L. Hayes; L.L. Ingram; B.L. Strom; L.M. Roton; M.W. Boyette; M.T. Walsh

    1994-01-01

    Gas chromatography/mass spectometry analysis of resin collected before and after injections of loblolly pines (Pinus taeda L.) with a fungicide mixture known to make pines more "attractive" to southern pine beetle, Dendroctonus frontalis Zimm., resulted in the identification of 4-allylanisole as a likely candidate for repellent effects....

  8. A reagentless amperometric biosensor for alcohol detection in column liquid chromatography based on co-immobilized peroxidase and alcohol oxidase in carbon paste.

    PubMed

    Johansson, K; Jönsson-Pettersson, G; Gorton, L; Marko-Varga, G; Csöregi, E

    1993-12-01

    A reagentless carbon paste electrode chemically modified with covalently bound alcohol oxidase and horse-radish peroxidase was examined as a selective sensor in flow injection and column liquid chromatography. A combination of carbodiimide, glutaraldehyde, and polyethyleneimine was used for immobilizing the enzymes in the paste. The surface of the electrodes was protected by first forming a layer of electropolymerized ortho-phenylenediamine followed by deposition of a cation exchange membrane (Eastman AQ 29D). The electrodes were used for detection of hydrogen peroxide, methanol, ethanol, propanol, isopropanol, and butanol. Preliminary investigations of the use of this sensor for bioprocess control are reported.

  9. An open-pattern droplet-in-oil planar array for single cell analysis based on sequential inkjet printing technology.

    PubMed

    Wang, Chenyu; Liu, Wenwen; Tan, Manqing; Sun, Hongbo; Yu, Yude

    2017-07-01

    Cellular heterogeneity represents a fundamental principle of cell biology for which a readily available single-cell research tool is urgently required. Here, we present a novel method combining cell-sized well arrays with sequential inkjet printing. Briefly, K562 cells with phosphate buffer saline buffer were captured at high efficiency (74.5%) in a cell-sized well as a "primary droplet" and sealed using fluorinated oil. Then, piezoelectric inkjet printing technology was adapted to precisely inject the cell lysis buffer and the fluorogenic substrate, fluorescein-di-β-D-galactopyranoside, as a "secondary droplet" to penetrate the sealing oil and fuse with the "primary droplet." We thereby successfully measured the intracellular β-galactosidase activity of K562 cells at the single-cell level. Our method allows, for the first time, the ability to simultaneously accommodate the high occupancy rate of single cells and sequential addition of reagents while retaining an open structure. We believe that the feasibility and flexibility of our method will enhance its use as a universal single-cell research tool as well as accelerate the adoption of inkjet printing in the study of cellular heterogeneity.

  10. Sequential photocatalyst-assisted digestion and vapor generation device coupled with anion exchange chromatography and inductively coupled plasma mass spectrometry for speciation analysis of selenium species in biological samples.

    PubMed

    Tsai, Yun-ni; Lin, Cheng-hsing; Hsu, I-hsiang; Sun, Yuh-chang

    2014-01-02

    We have developed an on-line sequential photocatalyst-assisted digestion and vaporization device (SPADVD), which operates through the nano-TiO2-catalyzed photo-oxidation and reduction of selenium (Se) species, for coupling between anion exchange chromatography (LC) and inductively coupled plasma mass spectrometry (ICP-MS) systems to provide a simple and sensitive hyphenated method for the speciation analysis of Se species without the need for conventional chemical digestion and vaporization techniques. Because our proposed on-line SPADVD allows both organic and inorganic Se species in the column effluent to be converted on-line into volatile Se products, which are then measured directly through ICP-MS, the complexity of the procedure and the probability of contamination arising from the use of additional chemicals are both low. Under the optimized conditions for SPADVD - using 1g of nano-TiO2 per liter, at pH 3, and illuminating for 80 s - we found that Se(IV), Se(VI), and selenomethionine (SeMet) were all converted quantitatively into volatile Se products. In addition, because the digestion and vaporization efficiencies of all the tested selenicals were improved when using our proposed on-line LC/SPADVD/ICP-MS system, the detection limits for Se(IV), Se(VI), and SeMet were all in the nanogram-per-liter range (based on 3σ). A series of validation experiments - analysis of neat and spiked extracted samples - indicated that our proposed methods could be applied satisfactorily to the speciation analysis of organic and inorganic Se species in the extracts of Se-enriched supplements. Copyright © 2013. Published by Elsevier B.V.

  11. Liquid chromatography, in combination with a quadrupole time-of-flight instrument (LC QTOF), with sequential window acquisition of all theoretical fragment-ion spectra (SWATH) acquisition: systematic studies on its use for screenings in clinical and forensic toxicology and comparison with information-dependent acquisition (IDA).

    PubMed

    Roemmelt, Andreas T; Steuer, Andrea E; Poetzsch, Michael; Kraemer, Thomas

    2014-12-02

    Forensic and clinical toxicological screening procedures are employing liquid chromatography-tandem mass spectrometry (LC-MS/MS) techniques with information-dependent acquisition (IDA) approaches more and more often. It is known that the complexity of a sample and the IDA settings might prevent important compounds from being triggered. Therefore, data-independent acquisition (DIA) methods should be more suitable for systematic toxicological analysis (STA). The DIA method sequential window acquisition of all theoretical fragment-ion spectra (SWATH), which uses Q1 windows of 20-35 Da for data-independent fragmentation, was systematically investigated for its suitability for STA. Quality of SWATH-generated mass spectra were evaluated with regard to mass error, relative abundance of the fragments, and library hits. With the Q1 window set to 20-25 Da, several precursors pass Q1 at the same time and are fragmented, thus impairing the library search algorithms to a different extent: forward fit was less affected than reverse fit and purity fit. Mass error was not affected. The relative abundance of the fragments was concentration dependent for some analytes and was influenced by cofragmentation, especially of deuterated analogues. Also, the detection rate of IDA compared to SWATH was investigated in a forced coelution experiment (up to 20 analytes coeluting). Even using several different IDA settings, it was observed that IDA failed to trigger relevant compounds. Screening results of 382 authentic forensic cases revealed that SWATH's detection rate was superior to IDA, which failed to trigger ∼10% of the analytes.

  12. Comparison of periodontal ligament injection and inferior alveolar nerve block in mandibular primary molars pulpotomy: a randomized control trial.

    PubMed

    Haghgoo, Roza; Taleghani, Ferial

    2015-05-01

    Inferior alveolar nerve block is a common technique for anesthesia of the primary mandibular molars. A number of disadvantages have been shown to be associated with this technique. Periodontal ligament (PDL) injection could be considered as an alternative to inferior alveolar nerve block. The aim of this study was to evaluate the effectiveness of PDL injection in the anesthesia of primary molar pulpotomy with mandibular block. This study was performed using a sequential double-blind randomized trial design. 80 children aged 3-7 years old who required pulpotomy in symmetrical mandibular primary molars were selected. The teeth of these children were anesthetized with periodontal injection on one side of the mandible and block on the other. Pulpotomy was performed on each patient during the same appointment. Signs of discomfort, including hand and body tension and eye movement, the verbal complaint and crying (SEM scale), were evaluated by a dental assistant who was blinded to the treatment allocation of the patients. Finally, the data were analyzed using the exact Fisher test and Pearson Chi-squared exact test. Success rate was 88/75 and 91/25 in the PDL injection and nerve block groups, respectively. There was no statistically significant difference between the two techniques (P = 0.250). Results showed that PDL injection can be used as an alternative to nerve block in pulpotomy of the mandibular primary molars.

  13. Pharmacokinetics of dinalbuphine sebacate and nalbuphine in human after intramuscular injection of dinalbuphine sebacate in an extended-release formulation.

    PubMed

    Tien, Yu En; Huang, Wen-Chuan; Kuo, Hui-Yuan; Tai, Lily; Uang, Yow-Shieng; Chern, Wendy H; Huang, Jin-Ding

    2017-11-01

    Nalbuphine is a semi-synthetic opioid indicated for the relief of moderate to severe pain. Its short half-life requires frequent injections in clinical practice, resulting in a greater incidence of adverse events. A prodrug of nalbuphine has been developed, dinalbuphine sebacate (DNS), dissolved in a simple oil-based injectable formulation, which could deliver and maintain an effective blood level of nalbuphine. An open-label, prospective, two-period study was performed in healthy volunteers to verify the extended blood concentration profile of nalbuphine. Twelve healthy Taiwanese were randomized to receive an intramuscular injection of 20 mg nalbuphine HCl and 150 mg DNS sequentially with a washout period of 5 days. To prevent DNS hydrolysis during sample analysis, the effect of four esterase inhibitors was evaluated in the quantitation of DNS in human whole blood and thenoyltrifluoroacetone was chosen. The bioavailability of nalbuphine from intramuscularly injected DNS relative to that from nalbuphine HCl was 85.4%. The mean absorption time of nalbuphine from DNS was 145.2 h. It took approximately 6 days for the complete release of DNS into the blood stream where DNS was rapidly hydrolysed to nalbuphine; suggesting a single injection of 150 mg DNS in our extended-release formulation could provide long-lasting pain relief. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Efficacy of premixed versus sequential administration of clonidine as an adjuvant to hyperbaric bupivacaine intrathecally in cesarean section

    PubMed Central

    Sachan, Prachee; Kumar, Nidhi; Sharma, Jagdish Prasad

    2014-01-01

    Background: Density of the drugs injected intrathecally is an important factor that influences spread in the cerebrospinal fluid. Mixing adjuvants with local anesthetics (LA) alters their density and hence their spread compared to when given sequentially in seperate syringes. Aims: To evaluate the efficacy of intrathecal administration of hyperbaric bupivacaine (HB) and clonidine as a mixture and sequentially in terms of block characteristics, hemodynamics, neonatal outcome, and postoperative pain. Setting and Design: Prospective randomized single blind study at a tertiary center from 2010 to 2012. Materials and Methods: Ninety full-term parturient scheduled for elective cesarean sections were divided into three groups on the basis of technique of intrathecal drug administration. Group M received mixture of 75 μg clonidine and 10 mg HB 0.5%. Group A received 75 μg clonidine after administration of 10 mg HB 0.5% through separate syringe. Group B received 75 μg clonidine before HB 0.5% (10 mg) through separate syringe. Statistical analysis used: Observational descriptive statistics, analysis of variance with Bonferroni multiple comparison post hoc test, and Chi-square test. Results: Time to achieve complete sensory and motor block was less in group A and B in which drugs were given sequentially. Duration of analgesia lasted longer in group B (474.3 ± 20.79 min) and group A (472.50 ± 22.11 min) than in group M (337 ± 18.22 min) with clinically insignificant influence on hemodynamic parameters and sedation. Conclusion: Sequential technique reduces time to achieve complete sensory and motor block, delays block regression, and significantly prolongs the duration of analgesia. However, it did not matter much whether clonidine was administered before or after HB. PMID:25886098

  15. Analyses of sulfonamide antibiotics by a successive anion- and cation-selective injection coupled to microemulsion electrokinetic chromatography.

    PubMed

    Lin, Yun-Ta; Liu, Yu-Wei; Cheng, Yi-Jie; Huang, Hsi-Ya

    2010-07-01

    In this study, an MEEKC was used to detect and analyze nine sulfonamide antibiotics. Owing to an insufficient sensitivity of on-column UV detection, a field-amplified sample injection, successive anion- and cation-selective injection, was used for the on-line concentration of the nine antibiotics. In the successive anion- and cation-selective injection mode, a leading water plug was introduced prior to anion injection, and then an acidic plug followed by a terminal water plug had to be used before subsequent cation injection. The results indicated some sulfonamides (sulfamonomethoxine, sulfamethazine, sulfamerazine and sulfadiazine) were determined as split signals in pairs, and this was likely due to the use of a longer acid plug (360 s) which caused the sulfonamide anions and cations to be stacked in two distinct zones of the leading water and acid plugs. Meanwhile, all the sulfonamides that were introduced either by anion or cation injection were stacked within the leading water plug when a shorter acid plug (210 s) was used. As a result, the nine sulfonamides were determined as single and symmetrical peaks with low LODs (0.9-4.2 microg/L). Furthermore, the MEEKC method was successfully applied for the detection of trace sulfonamide residues in several food and water samples.

  16. Dual nozzle single pump fuel injection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, C.

    1992-02-25

    This patent describes an improvement in a fuel injection system in a stratified charge hybrid internal combustion engine including a main combustion chamber, a precombustion chamber connected with the main chamber, fuel injectors in the main combustion chamber and precombustion chamber which open at higher and lower pressure levels respectively to sequentially inject fuel into the prechamber and the main chamber, timed spark ignition means in the prechamber for ignition of the fuel-air mixture therein, and an engine driven and timed fuel injection pump having a variable output capacity that varies with power level position, the injection pump is suppliedmore » by a low pressure charging pump. The improvement comprises: a shuttle valve including a bore therein; a shuttle spool means positioned within the bore defining a prechamber supply chamber on one side thereof and a spool activation chamber on the opposite side thereof the spool means having a first and second position; biasing means urging the spool towards it first position with the spool actuation chamber at its minimum volume; first conduit means connecting charging pressure to the prechamber supply camber in the first position oil the spool means; second conduit means connecting the injection pump to spool actuation chamber; third conduit means connecting the spool actuating chamber with the main injector; forth conduit means connecting the prechamber supply chamber with the prechamber injector; the initial charge from the injection pump actuates the spool means from its fir to its second position.« less

  17. Analytical validation applied to simultaneous determination of solvents dichloromethane (DCM), methyl isobutyl ketone (MIBK), tetrahydrofuran (THF) and toluene (TOL) in urine by headspace extraction and injection on chromatographic system with a flame ionization detector

    NASA Astrophysics Data System (ADS)

    Muna, E. D. M.; Pereira, R. P.

    2016-07-01

    The determination of the volatile organic solvents dichloromethane (DCM), methyl isobutyl ketone (MIBK), tetrahydrofuran (THF) and toluene (TOL) is applied on toxicological monitoring of employees in various industrial activities. The gas chromatography technique with flame ionization detector and headspace injection system has been applied. The analytical procedure developed allows the simultaneous determination of the above-mentioned solvents and the accuracy of the method was tested following the INMETRO guidelines through the DOQ-CGRE 008 Rev.04-July/2011.

  18. Tylosin depletion from edible pig tissues.

    PubMed

    Prats, C; El Korchi, G; Francesch, R; Arboix, M; Pérez, B

    2002-12-01

    The depletion of tylosin from edible pig tissues was studied following 5 days of intramuscular (i.m.) administration of 10 mg/kg of tylosin to 16 crossbreed pigs. Animals were slaughtered at intervals after treatment and samples of muscle, kidney, liver, skin+fat, and injection site were collected and analysed by high-performance liquid chromatography (HPLC). Seven days after the completion of treatment, the concentration of tylosin in kidney, skin+fat, and at the injection site was higher than the European Union maximal residue limit (MRL) of 100 microg/kg. Tylosin residues in all tissues were below the quantification limit (50 microg/kg) at 10 and 14 days post-treatment.

  19. A Telescopic and Microscopic Examination of Acceleration in the June 2015 Geomagnetic Storm: Magnetospheric Multiscale and Van Allen Probes Study of Substorm Particle Injection

    NASA Technical Reports Server (NTRS)

    Baker, D. N.; Jaynes, A. N.; Turner, D. L.; Nakamura, R.; Schmid, D.; Mauk, B. H.; Cohen, I. J.; Fennell, J. F.; Blake, J. B.; Strangeway, R. J.; hide

    2016-01-01

    An active storm period in June 2015 showed that particle injection events seen sequentially by the four (MagnetosphericMultiscale) MMS spacecraft subsequently fed the enhancement of the outer radiation belt observed by Van Allen Probes mission sensors. Several episodes of significant southward interplanetary magnetic field along with a period of high solar wind speed (Vsw 500kms) on 22 June occurred following strong interplanetary shock wave impacts on the magnetosphere. Key events on 22 June 2015 show that the magnetosphere progressed through a sequence of energy-loading and stress-developing states until the entire system suddenly reconfigured at 19:32 UT. Energetic electrons, plasma, and magnetic fields measured by the four MMS spacecraft revealed clear dipolarization front characteristics. It was seen that magnetospheric substorm activity provided a seed electron population as observed by MMS particle sensors as multiple injections and related enhancements in electron flux.

  20. Speciation analysis of mercury by solid-phase microextraction and multicapillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight-mass spectrometry.

    PubMed

    Jitaru, Petru; Adams, Freddy C

    2004-11-05

    This paper reports the development of an analytical approach for speciation analysis of mercury at ultra-trace levels on the basis of solid-phase microextraction and multicapillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight mass spectrometry. Headspace solid-phase microextraction with a carboxen/polydimethylsyloxane fiber is used for extraction/preconcentration of mercury species after derivatization with sodium tetraethylborate and subsequent volatilization. Isothermal separation of methylmercury (MeHg), inorganic mercury (Hg2+) and propylmercury (PrHg) used as internal standard is achieved within a chromatographic run below 45 s without the introduction of spectral skew. Method detection limits (3 x standard deviation criteria) calculated for 10 successive injections of the analytical reagent blank are 0.027 pg g(-1) (as metal) for MeHg and 0.27 pg g(-1) for Hg2+. The repeatability (R.S.D., %) is 3.3% for MeHg and 3.8% for Hg2+ for 10 successive injections of a standard mixture of 10pg. The method accuracy for MeHg and total mercury is validated through the analysis of marine and estuarine sediment reference materials. A comparison of the sediment data with those obtained by a purge-and-trap injection (PTI) method is also addressed. The analytical procedure is illustrated with some results for the ultra-trace level analysis of ice from Antarctica for which the accuracy is assessed by spike recovery experiments.

  1. Multicapillary Gas Chromatography-Temperature Modulated Metal Oxide Semiconductor Sensors Array Detector for Monitoring of Volatile Organic Compounds in Closed Atmosphere Using Gaussian Apodization Factor Analysis.

    PubMed

    Alinoori, Amir Hossein; Masoum, Saeed

    2018-05-22

    A unique metal oxide semiconductor sensor (MOS) array detector with eight sensors was designed and fabricated in a PTFE chamber as an interface for coupling with multicapillary gas chromatography. This design consists of eight transfer lines with equal length between the multicapillary columns (MCC) and sensors. The deactivated capillary columns were passed through each transfer line and homemade flow splitter to distribute the same gas flow on each sensor. Using the eight ports flow splitter design helps us to equal the length of carrier gas path and flow for each sensor, minimizing the dead volume of the sensor's chamber and increasing chromatographic resolution. In addition to coupling of MCC to MOS array detector and other considerations in hardware design, modulation of MOS temperature was used to increase sensitivity and selectivity, and data analysis was enhanced with adapted Gaussian apodization factor analysis (GAFA) as a multivariate curve resolution algorithm. Continues air sampling and injecting system (CASI) design provides a fast and easily applied method for continues injection of air sample with no additional sample preparation. The analysis cycle time required for each run is less than 300 s. The high sample load and sharp injection with the fast separation by MCC decrease the peak widths and improve detection limits. This homemade customized instrument is an alternative to other time-consuming and expensive technologies for continuous monitoring of outgassing in air samples.

  2. Chemical Profiling of Re-Du-Ning Injection by Ultra-Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Quadrupole Time-of-Flight Mass Spectrometry through the Screening of Diagnostic Ions in MSE Mode

    PubMed Central

    Wang, Zhenzhong; Geng, Jianliang; Dai, Yi; Xiao, Wei; Yao, Xinsheng

    2015-01-01

    The broad applications and mechanism explorations of traditional Chinese medicine prescriptions (TCMPs) require a clear understanding of TCMP chemical constituents. In the present study, we describe an efficient and universally applicable analytical approach based on ultra-performance liquid chromatography coupled to electrospray ionization tandem quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q/TOF-MS) with the MSE (E denotes collision energy) data acquisition mode, which allowed the rapid separation and reliable determination of TCMP chemical constituents. By monitoring diagnostic ions in the high energy function of MSE, target peaks of analogous compounds in TCMPs could be rapidly screened and identified. “Re-Du-Ning” injection (RDN), a eutherapeutic traditional Chinese medicine injection (TCMI) that has been widely used to reduce fever caused by viral infections in clinical practice, was studied as an example. In total, 90 compounds, including five new iridoids and one new sesquiterpene, were identified or tentatively characterized by accurate mass measurements within 5 ppm error. This analysis was accompanied by MS fragmentation and reference standard comparison analyses. Furthermore, the herbal sources of these compounds were unambiguously confirmed by comparing the extracted ion chromatograms (EICs) of RDN and ingredient herbal extracts. Our work provides a certain foundation for further studies of RDN. Moreover, the analytical approach developed herein has proven to be generally applicable for profiling the chemical constituents in TCMPs and other complicated mixtures. PMID:25875968

  3. Successful outcome after intravenous gasoline injection.

    PubMed

    Domej, Wolfgang; Mitterhammer, Heike; Stauber, Rudolf; Kaufmann, Peter; Smolle, Karl Heinz

    2007-12-01

    Gasoline, ingested intentionally or accidentally, is toxic. The majority of reported cases of gasoline intoxication involve oral ingestion or inhalation. Data are scarce on complications and outcomes following hydrocarbon poisoning by intravenous injection. Following a suicide attempt by intravenous self-injection of 10 ml of gasoline, a 26-year-old medical student was admitted to the intensive care unit (ICU) with hemoptysis, symptoms of acute respiratory failure, chest pain, and severe abdominal cramps. Gas exchange was severely impaired and a chest x-ray indicated chemical pneumonitis. Initial treatment consisted of mechanical ventilation, supportive hyperventilation, administration of nitrogen oxide (NO), and prednisone. Unfortunately, the patient developed multi-organ dysfunction syndrome (MODS) complicated by life-threatening severe vasoplegia within 24 hours after gasoline injection. High doses of vasopressors along with massive amounts of parenteral fluids were necessary. Despite fluid replacement, renal function worsened and required hemofiltration on 5 sequential days. After 12 days of intensive care management, the patient recovered completely and was discharged to a psychiatric care facility. Intravenous gasoline injection causes major injury to the lungs, the organ bearing the first capillary bed encountered. Treatment of gasoline poisoning is symptomatic because no specific antidote is available. Early and aggressive supportive care may be conducive to a favorable outcome with minimal residual pulmonary sequelae.

  4. Development of septum-free injector for gas chromatography and its application to the samples with a high boiling point.

    PubMed

    Ito, Hiroshi; Hayakawa, Kazuichi; Yamamoto, Atsushi; Murase, Atsushi; Hayakawa, Kazumi; Kuno, Minoru; Inoue, Yoshinori

    2006-11-03

    A novel apparatus with a simple structure has been developed for introducing samples into the vaporizing chamber of a gas chromatograph. It requires no septum due to the gas sealing structure over the carrier gas supply line. The septum-free injector made it possible to use injection port temperatures as high as 450 degrees C. Repetitive injection of samples with boiling points below 300 degrees C resulted in peak areas with relative standard deviations between 1.25 and 3.28% (n=5) and good linearity (r(2)>0.9942) for the calibration curve. In the analysis of polycyclic aromatic hydrocarbons and a base oil, the peak areas of components with high boiling points increased as the injection port temperature was increased to 450 degrees C.

  5. Use of an injection port for thermochemolysis-gas chromatography/mass spectrometry: rapid profiling of biomaterials.

    PubMed

    Shadkami, Farzad; Helleur, Robert

    2009-07-31

    A simple and direct approach was developed for thermochemolytic analysis of a wide range of biomolecules present in plant materials using an injection port of a gas chromatograph/mass spectrometer (GC/MS) and a novel solids injector consisting of a coiled stainless steel wire placed inside a modified needle syringe. Optimum thermochemolysis (or Thermally Assisted Hydrolysis/Methylation) was achieved by using a suitable methanolic solution of trimethylsulfonium hydroxide (TMSH) or tetramethylammonium hydroxide (TMAH) with an injection port temperature of 350 degrees C. Intact, methylated flavonoids, saccharides, phenolic and fatty acids, lignin dimers and diterpene resin acids were identified. Samples include tea leaves, hemicelluloses, lignin isolates and herbal medicines. Unexpected chromatographic results using TMAH reagent revealed the presence of intact methylated trisaccharides (658 Da) and structurally informative dimer lignin markers.

  6. Development of a sensitive GC-C-IRMS method for the analysis of androgens.

    PubMed

    Polet, Michael; Van Gansbeke, Wim; Deventer, Koen; Van Eenoo, Peter

    2013-02-01

    The administration of anabolic steroids is one of the most important issues in doping control and is detectable through a change in the carbon isotopic composition of testosterone and/or its metabolites. Gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS), however, remains a very laborious and expensive technique and substantial amounts of urine are needed to meet the sensitivity requirements of the IRMS. This can be problematic because only a limited amount of urine is available for anti-doping analysis on a broad spectrum of substances. In this work we introduce a new type of injection that increases the sensitivity of GC-C-IRMS by a factor of 13 and reduces the limit of detection, simply by using solvent vent injections instead of splitless injection. This drastically reduces the amount of urine required. On top of that, by only changing the injection technique, the detection parameters of the IRMS are not affected and there is no loss in linearity. Copyright © 2012 John Wiley & Sons, Ltd.

  7. Three-Dimensional Changes in the Midface Following Malar Calcium Hydroxyapatite Injection in a Cadaver Model.

    PubMed

    Gatherwright, James R; Brown, Matthew S; Katira, Kristopher M; Rowe, David J

    2015-08-01

    Three-dimensional (3D) changes in the midface following malar calcium hydroxyapatite (CaHa) injection have not been systematically analyzed. The authors analyzed 3D volume changes in midface and naso-labial fold (NLF) volume, as well as lateral movement in the NLF/naso-labial crease (NLC) junction following malar injection of CaHa in a cadaver model. A single surgeon injected CaHa in the supraperiosteal plane. Sequential images were obtained with the VECTRA 3D system pre- and post-1.5- and 3-cc CaHa injections. All measurements were performed by a single examiner. Injection location was verified anatomically. Injections were performed in 16 fresh cadaver hemi-faces. Maximal increases in projection were centered on the malar injection site, with associated decreases in projection and volume in the infero-medial locations. Relative mean increases in volume of 3.16 cc and 4.94 cc were observed following the 1.5-cc and 3-cc injections, respectively. There was a relative decrease in the volume of the NLF of -0.3 cc and -0.4 cc following the 1.5- and 3-cc injections, respectively. Injection of CaHa was associated with lateral movements of the NLF-NLC junction at the level of the nasal sill, philtral columns, and oral commissure, measuring 2.7, 2.5, and 1.9 mm and 2.8, 2.9, and 2.4 mm following the 1.5- and 3-cc injections, respectively. Anatomical dissection verified the location in the supraperiosteal space and within the middle malar fat pad. Following malar CaHa injection, 3D photographic analysis showed a measureable lifting effect with recruitment of ptotic tissue and lateral movement of the NLF-NLC junction in a cadaver model. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  8. Sequential bottom-up assembly of mechanically stabilized synthetic cells by microfluidics

    NASA Astrophysics Data System (ADS)

    Weiss, Marian; Frohnmayer, Johannes Patrick; Benk, Lucia Theresa; Haller, Barbara; Janiesch, Jan-Willi; Heitkamp, Thomas; Börsch, Michael; Lira, Rafael B.; Dimova, Rumiana; Lipowsky, Reinhard; Bodenschatz, Eberhard; Baret, Jean-Christophe; Vidakovic-Koch, Tanja; Sundmacher, Kai; Platzman, Ilia; Spatz, Joachim P.

    2018-01-01

    Compartments for the spatially and temporally controlled assembly of biological processes are essential towards cellular life. Synthetic mimics of cellular compartments based on lipid-based protocells lack the mechanical and chemical stability to allow their manipulation into a complex and fully functional synthetic cell. Here, we present a high-throughput microfluidic method to generate stable, defined sized liposomes termed `droplet-stabilized giant unilamellar vesicles (dsGUVs)’. The enhanced stability of dsGUVs enables the sequential loading of these compartments with biomolecules, namely purified transmembrane and cytoskeleton proteins by microfluidic pico-injection technology. This constitutes an experimental demonstration of a successful bottom-up assembly of a compartment with contents that would not self-assemble to full functionality when simply mixed together. Following assembly, the stabilizing oil phase and droplet shells are removed to release functional self-supporting protocells to an aqueous phase, enabling them to interact with physiologically relevant matrices.

  9. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice

    NASA Astrophysics Data System (ADS)

    Evans, Eleanor; Sawiak, Stephen J.; Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T.

    2014-01-01

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time-activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration-time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18F-FDG respectively to ascertain the technique‧s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  10. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice.

    PubMed

    Evans, Eleanor; Sawiak, Stephen J; Ward, Alexander O; Buonincontri, Guido; Hawkes, Robert C; Carpenter, T Adrian

    2014-01-11

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time-activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration-time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18 F-FDG respectively to ascertain the technique's validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  11. Application of silver nanoparticles to the chemiluminescence determination of cefditoren pivoxil using the luminol-ferricyanide system.

    PubMed

    Alarfaj, Nawal A; Aly, Fatma A; El-Tohamy, Maha F

    2015-02-01

    A new simple, accurate and sensitive sequential injection analysis chemiluminescence (CL) detection method for the determination of cefditoren pivoxil (CTP) has been developed. The developed method was based on the enhancement effect of silver nanoparticles on the CL signal arising from a luminol-potassium ferricyanide reaction in the presence of CTP. The optimum conditions relevant to the effect of luminol, potassium ferricyanide and silver nanoparticle concentrations were investigated. The proposed method showed linear relationships between relative CL intensity and the investigated drug concentration at the range 0.001-5000 ng/mL, (r = 0.9998, n = 12) with a detection limit of 0.5 pg/mL and quantification limit of 0.001 ng/mL. The relative standard deviation was 1.6%. The proposed method was employed for the determination of CTP in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated. In addition, the interference of some related cephalosporins was tested. No interference was recorded. The obtained sequential injection analysis-CL results were statistically compared with those from a reported method and did not show any significant differences. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Sequential determination of multi-nutrient elements in natural water samples with a reverse flow injection system.

    PubMed

    Lin, Kunning; Ma, Jian; Yuan, Dongxing; Feng, Sichao; Su, Haitao; Huang, Yongming; Shangguan, Qipei

    2017-05-15

    An integrated system was developed for automatic and sequential determination of NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ in natural waters based on reverse flow injection analysis combined with spectrophotometric detection. The system operation was controlled by a single chip microcomputer and laboratory-programmed software written in LabVIEW. The experimental parameters for each nutrient element analysis were optimized based on a univariate experimental design, and interferences from common ions were evaluated. The upper limits of the linear range (along with detection limit, µmolL -1 ) of the proposed method was 20 (0.03), 200 (0.7), 12 (0.3), 5 (0.03), 5 (0.03), 9 (0.2) µmolL -1 , for NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ , respectively. The relative standard deviations were below 5% (n=9-13) and the recoveries varied from 88.0±1.0% to 104.5±1.0% for spiked water samples. The sample throughput was about 20h -1 . This system has been successfully applied for the determination of multi-nutrient elements in different kinds of water samples and showed good agreement with reference methods (slope 1.0260±0.0043, R 2 =0.9991, n=50). Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Sequential injection system with in-line solid phase extraction and soil mini-column for determination of zinc and copper in soil leachates.

    PubMed

    Paluch, Justyna; Mesquita, Raquel B R; Cerdà, Víctor; Kozak, Joanna; Wieczorek, Marcin; Rangel, António O S S

    2018-08-01

    A sequential injection (SI) system equipped with in-line solid phase extraction column and in-line soil mini-column is proposed for determination of zinc and copper in soil leachates. The spectrophotometric determination (560 nm) is based on the reaction of both analytes with 1-(2-Pyridylazo)-2-naphthol (PAN). Zinc is determined after retaining copper on a cationic resin (Chelex100) whereas copper is determined from the difference of the absorbance measured for both analytes, introduced into the system with the use of a different channel, and zinc absorbance. The influence of several potential interferences was studied. Using the developed method, zinc and copper were determined within the concentration ranges of 0.005-0.300 and 0.011-0.200 mg L -1 , and with a relative standard deviation lower than 6.0% and 5.1%, respectively. The detection limits are 1.4 and 3.0 µg/L for determination of zinc and copper, respectively. The developed SI method was verified by the determination of both analytes in synthetic and certified reference materials of water samples, and applied to the determination of the analytes in rain water and soil leachates from laboratory scale soil core column and in-line soil mini-column. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Validation of antibiotic residue tests for dairy goats.

    PubMed

    Zeng, S S; Hart, S; Escobar, E N; Tesfai, K

    1998-03-01

    The SNAP test, LacTek test (B-L and CEF), Charm Bacillus sterothermophilus var. calidolactis disk assay (BsDA), and Charm II Tablet Beta-lactam sequential test were validated using antibiotic-fortified and -incurred goat milk following the protocol for test kit validations of the U.S. Food and Drug Administration Center for Veterinary Medicine. SNAP, Charm BsDA, and Charm II Tablet Sequential tests were sensitive and reliable in detecting antibiotic residues in goat milk. All three assays showed greater than 90% sensitivity and specificity at tolerance and detection levels. However, caution should be taken in interpreting test results at detection levels. Because of the high sensitivity of these three tests, false-violative results could be obtained in goat milk containing antibiotic residues below the tolerance level. Goat milk testing positive by these tests must be confirmed using a more sophisticated methodology, such as high-performance liquid chromatography, before the milk is condemned. LacTek B-L test did not detect several antibiotics, including penicillin G, in goat milk at tolerance levels. However, LacTek CEF was excellent in detecting ceftiofur residue in goat milk.

  15. Sequential microwave superheated water extraction of mannans from spent coffee grounds.

    PubMed

    Passos, Cláudia P; Moreira, Ana S P; Domingues, M Rosário M; Evtuguin, Dmitry V; Coimbra, Manuel A

    2014-03-15

    The feasibility of using sequential microwave superheated water extraction (MAE) for the recovery of mannans from spent coffee grounds (SCG) was studied. Due to the high contents of mannose still present in the SCG residue left after two consecutive MAE, the unextracted material was re-suspended in water and submitted to a third microwave irradiation (MAE3) at 200 °C for 3 min. With MAE3, mannose recovery achieved 48%, increasing to 56% by MAE4, and reaching a maximum of 69% with MAE5. Glycosidic-linkage analysis showed that in MAE3 mainly galactomannans were recovered, while debranched galactomannans were recovered with MAE4 and MAE5. With increasing the number of extractions, the average degree of polymerization of the mannans decreased, as observed by size-exclusion chromatography and by methylation analysis. Scanning electron microscopy images showed a decrease on cell walls thickness. After final MAE5, the remaining un-extracted insoluble material, representing 22% of the initial SCG, was composed mainly by cellulose (84%). Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Soil and sediment sample analysis for the sequential determination of natural and anthropogenic radionuclides.

    PubMed

    Michel, H; Levent, D; Barci, V; Barci-Funel, G; Hurel, C

    2008-02-15

    A new sequential method for the determination of both natural (U, Th) and anthropogenic (Sr, Cs, Pu, Am) radionuclides has been developed for application to soil and sediment samples. The procedure was optimised using a reference sediment (IAEA-368) and reference soils (IAEA-375 and IAEA-326). Reference materials were first digested using acids (leaching), 'total' acids on hot plate, and acids in microwave in order to compare the different digestion technique. Then, the separation and purification were made by anion exchange resin and selective extraction chromatography: transuranic (TRU) and strontium (SR) resins. Natural and anthropogenic alpha radionuclides were separated by uranium and tetravalent actinide (UTEVA) resin, considering different acid elution medium. Finally, alpha and gamma semiconductor spectrometer and liquid scintillation spectrometer were used to measure radionuclide activities. The results obtained for strontium-90, cesium-137, thorium-232, uranium-238, plutonium-239+240 and americium-241 isotopes by the proposed method for the reference materials provided excellent agreement with the recommended values and good chemical recoveries. Plutonium isotopes in alpha spectrometry planchet deposits could be also analysed by ICPMS.

  17. Preparation and evaluation of diblock copolymer-grafted silica by sequential surface initiated-atom transfer radical polymerization for reverse-phase/ion-exchange mixed-mode chromatography.

    PubMed

    Bo, Chun Miao; Wang, Chaozhan; Wei, Yin Mao

    2017-12-01

    A novel approach that involved the grafting of diblock copolymer with two types of monomer onto substrate by sequential surface initiated-atom transfer radical polymerization was proposed to prepare a mixed-mode chromatographic stationary phase. The distinguishing feature of this method is that it can be applied in the preparation of various mixed-mode stationary phases. In this study, a new reverse-phase/ion-exchange stationary phase was prepared by grafting hydrophobic styrene and cationic sodium 4-styrenesulfonate by the proposed approach onto silica surface. The chromatographic properties of the prepared stationary phase were evaluated by the separation of benzene derivatives, anilines, and β-agonists, and by the effect of pH values and acetonitrile content on the retention. Compared with typical RP columns, the prepared stationary phase achieved the better resolution and higher selectivity at a shorter separation time and lower organic content. Moreover, the application of the prepared column was proved by separating widely distributed polar and charged compounds simultaneously. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Structure of the mouse glucocorticoid receptor: rapid analysis by size-exclusion high-performance liquid chromatography.

    PubMed

    LaPointe, M C; Chang, C H; Vedeckis, W V

    1986-04-22

    Gel-exclusion high-performance liquid chromatography (HPLC) has been used to separate the untransformed from the transformed glucocorticoid receptor (GC-R) extracted from mouse AtT-20 cells. With 200 mM potassium phosphate as the eluent, an efficient separation of the forms of the GC-R is attained in 15-20 min. The untransformed cytosolic GC-R elutes from the column with a Stokes radius (Rs) of 8.2-8.6 nm, as do the molybdate-stabilized GC-R, the purified untransformed GC-R, and the cross-linked cytosolic GC-R. GC-R transformed in vitro by either ammonium sulfate precipitation, KCl treatment, or G-25 chromatography elutes with an Rs of 5.7-6 nm. Also, GC-R extracted from the nucleus with either 0.3 M KCl or 2 mM sodium tungstate, or purified by two cycles of DNA-cellulose chromatography, has an Rs of 5.5-6.3 nm. The data are identical either in the presence or in the absence of 20 mM Na2MoO4, suggesting that molybdate is not causing aggregation to produce a larger Rs value than that of the native receptor. Vertical tube rotor sucrose gradient ultracentrifugation of cytosol produces three forms of the GC-R: 9.1 S, 5.2 S, and 3.8 S. Sequential analysis of the GC-R forms by HPLC and vertical tube rotor ultracentrifugation and vice versa allows for the hydrodynamic determination of molecular weight within a very short time period (2-3 h total).(ABSTRACT TRUNCATED AT 250 WORDS)

  19. A LabVIEW®-based software for the control of the AUTORAD platform: a fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis.

    PubMed

    Barbesi, Donato; Vicente Vilas, Víctor; Millet, Sylvain; Sandow, Miguel; Colle, Jean-Yves; Aldave de Las Heras, Laura

    2017-01-01

    A LabVIEW ® -based software for the control of the fully automated multi-sequential flow injection analysis Lab-on-Valve (MSFIA-LOV) platform AutoRAD performing radiochemical analysis is described. The analytical platform interfaces an Arduino ® -based device triggering multiple detectors providing a flexible and fit for purpose choice of detection systems. The different analytical devices are interfaced to the PC running LabVIEW ® VI software using USB and RS232 interfaces, both for sending commands and receiving confirmation or error responses. The AUTORAD platform has been successfully applied for the chemical separation and determination of Sr, an important fission product pertinent to nuclear waste.

  20. Enabling Microliquid Chromatography by Microbead Packing of Microchannels

    NASA Technical Reports Server (NTRS)

    Balvin, Manuel; Zheng, Yun

    2013-01-01

    The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

  1. High-throughput quantification for a drug mixture in rat plasma-a comparison of Ultra Performance liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Yu, Kate; Little, David; Plumb, Rob; Smith, Brian

    2006-01-01

    A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.

  2. "Dilute-and-inject" multi-target screening assay for highly polar doping agents using hydrophilic interaction liquid chromatography high resolution/high accuracy mass spectrometry for sports drug testing.

    PubMed

    Görgens, Christian; Guddat, Sven; Orlovius, Anne-Katrin; Sigmund, Gerd; Thomas, Andreas; Thevis, Mario; Schänzer, Wilhelm

    2015-07-01

    In the field of LC-MS, reversed phase liquid chromatography is the predominant method of choice for the separation of prohibited substances from various classes in sports drug testing. However, highly polar and charged compounds still represent a challenging task in liquid chromatography due to their difficult chromatographic behavior using reversed phase materials. A very promising approach for the separation of hydrophilic compounds is hydrophilic interaction liquid chromatography (HILIC). Despite its great potential and versatile advantages for the separation of highly polar compounds, HILIC is up to now not very common in doping analysis, although most manufacturers offer a variety of HILIC columns in their portfolio. In this study, a novel multi-target approach based on HILIC high resolution/high accuracy mass spectrometry is presented to screen for various polar stimulants, stimulant sulfo-conjugates, glycerol, AICAR, ethyl glucuronide, morphine-3-glucuronide, and myo-inositol trispyrophosphate after direct injection of diluted urine specimens. The usage of an effective online sample cleanup and a zwitterionic HILIC analytical column in combination with a new generation Hybrid Quadrupol-Orbitrap® mass spectrometer enabled the detection of highly polar analytes without any time-consuming hydrolysis or further purification steps, far below the required detection limits. The methodology was fully validated for qualitative and quantitative (AICAR, glycerol) purposes considering the parameters specificity; robustness (rRT < 2.0%); linearity (R > 0.99); intra- and inter-day precision at low, medium, and high concentration levels (CV < 20%); limit of detection (stimulants and stimulant sulfo-conjugates < 10 ng/mL; norfenefrine; octopamine < 30 ng/mL; AICAR < 10 ng/mL; glycerol 100 μg/mL; ETG < 100 ng/mL); accuracy (AICAR 103.8-105.5%, glycerol 85.1-98.3% at three concentration levels) and ion suppression/enhancement effects.

  3. Enabling Microliquid Chromatography by Microbead Packing of Microchannels

    NASA Technical Reports Server (NTRS)

    Balvin, Manuel; Zheng, Yun

    2014-01-01

    The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

  4. MODEL FOR NON-EQUILIBRIUM BINDING AND AFFINITY CHROMATOGRAPHY WITH CHARACTERIZATION OF 8-HYDROXYQUINOLINE IMMOBILIZED ON CONTROLLED PORE GLASS USING A FLOW INJECTION SYSTEM WITH A PACKED MICRO-COLUMN. (R826694C651)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  5. Analysis of Androgenic Steroids in Environmental Waters by Large-volume Injection Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Backe, Will J.; Ort, Christoph; Brewer, Alex J.; Field, Jennifer A.

    2014-01-01

    A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrices using direct large-volume injection (LVI) high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 88 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 360 ng/L. The method was demonstrated on a series of 1-hr composite wastewater influent samples collected over a day with the purpose of assessing temporal profiles of androgen loads in wastewater. Testosterone, androstenedione, boldenone, and nandrolone were detected in the sample series at concentrations up to 290 ng/L and loads up to 535 mg. Boldenone, a synthetic androgen, had a temporal profile that was strongly correlated to testosterone, a natural human androgen, suggesting its source may be endogenous. An analysis of the sample particulate fraction revealed detectable amounts of sorbed testosterone and androstenedione. Androstenedione sorbed to the particulate fraction accounted for an estimated five to seven percent of the total androstenedione mass. PMID:21391574

  6. Analysis of androgenic steroids in environmental waters by large-volume injection liquid chromatography tandem mass spectrometry.

    PubMed

    Backe, Will J; Ort, Christoph; Brewer, Alex J; Field, Jennifer A

    2011-04-01

    A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrixes using direct large-volume injection (LVI) high-performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 87.6 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 360 ng/L. The method was demonstrated on a series of 1 h composite wastewater influent samples collected over a day with the purpose of assessing temporal profiles of androgen loads in wastewater. Testosterone, androstenedione, boldenone, and nandrolone were detected in the sample series at concentrations up to 290 ng/L and loads up to 535 mg/h. Boldenone, a synthetic androgen, had a temporal profile that was strongly correlated to testosterone, a natural human androgen, suggesting its source may be endogenous. An analysis of the sample particulate fraction revealed detectable amounts of sorbed testosterone and androstenedione. Androstenedione sorbed to the particulate fraction accounted for an estimated 5 to 7% of the total androstenedione mass.

  7. Analysis of iodinated haloacetic acids in drinking water by reversed-phase liquid chromatography/electrospray ionization/tandem mass spectrometry with large volume direct aqueous injection.

    PubMed

    Li, Yongtao; Whitaker, Joshua S; McCarty, Christina L

    2012-07-06

    A large volume direct aqueous injection method was developed for the analysis of iodinated haloacetic acids in drinking water by using reversed-phase liquid chromatography/electrospray ionization/tandem mass spectrometry in the negative ion mode. Both the external and internal standard calibration methods were studied for the analysis of monoiodoacetic acid, chloroiodoacetic acid, bromoiodoacetic acid, and diiodoacetic acid in drinking water. The use of a divert valve technique for the mobile phase solvent delay, along with isotopically labeled analogs used as internal standards, effectively reduced and compensated for the ionization suppression typically caused by coexisting common inorganic anions. Under the optimized method conditions, the mean absolute and relative recoveries resulting from the replicate fortified deionized water and chlorinated drinking water analyses were 83-107% with a relative standard deviation of 0.7-11.7% and 84-111% with a relative standard deviation of 0.8-12.1%, respectively. The method detection limits resulting from the external and internal standard calibrations, based on seven fortified deionized water replicates, were 0.7-2.3 ng/L and 0.5-1.9 ng/L, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. A Microwave Flow Detector for Gradient Elution Liquid Chromatography.

    PubMed

    Ye, Duye; Wang, Weizheng; Moline, David; Islam, Md Saiful; Chen, Feng; Wang, Pingshan

    2017-10-17

    This study presents a microwave flow detector technique for liquid chromatography (LC) application. The detector is based on a tunable microwave interferometer (MIM) with a vector network analyzer (VNA) for signal measurement and a computer for system control. A microstrip-line-based 0.3 μL flow cell is built and incorporated into the MIM. With syringe pump injection, the detector is evaluated by measuring a few common chemicals in DI water at multiple frequencies from 0.98 to 7.09 GHz. Less than 30 ng minimum detectable quantity (MDQ) is demonstrated. An algorithm is provided and used to obtain sample dielectric permittivity at each frequency point. When connected to a commercial HPLC system and injected with a 10 μL aliquot of 10 000 ppm caffeine DI-water solution, the microwave detector yields a signal-to-noise ratio (SNR) up to 10 under isocratic and gradient elution operations. The maximum sampling rate is 20 Hz. The measurements show that MIM tuning, aided by a digital tunable attenuator (DTA), can automatically adjust MIM operation to retain detector sensitivity when mobile phase changes. Furthermore, the detector demonstrates a capability to quantify coeluted vitamin E succinate (VES) and vitamin D 3 (VD 3 ).

  9. Analysis of chlorophenoxy acid herbicides in water by large-volume on-line derivatization and gas chromatography-mass spectrometry.

    PubMed

    Ding, W H; Liu, C H; Yeh, S P

    2000-10-27

    This work presents a modified method to analyze chlorophenoxy acid herbicides in water samples. The herbicides 2,4-D (2,4-dichlorophenoxyacetic acid). Silvex (2,4,5-trichlorophenoxypropionic acid) and 2,4,5-T (2,4,5-trichlorophenoxyacetic acid) were used to evaluate the method. The method involves extraction of samples by a graphitized carbon black cartridge, and on-line derivatization in the GC injection port using a large-volume (10-20 microl) direct sample introduction (DSI) device with tetraalkylammonium salts. The analytes were then identified and quantitated by ion-trap gas chromatography-mass spectrometry. The large-volume DSI injection-port derivatization technique provides sensitivity, fast and reproducible results for chlorophenoxy acid herbicides residues, to quantitation at 0.1 to 0.2 microg/l in 500-ml water samples. An enhanced characteristic mass chromatogram of molecular ions of butylated chlorophenoxy acid herbicides with a significant chlorine isotope pattern by electron impact ionization MS allows us to determine herbicides residues at trace levels in aqueous samples. Recovery of the herbicide residues in spiked various water samples ranged from 70 to 99% while RSDs ranged from 1 to 13%.

  10. Method for the determination of carboxylic acids in industrial effluents using dispersive liquid-liquid microextraction with injection port derivatization gas chromatography-mass spectrometry.

    PubMed

    Makoś, Patrycja; Fernandes, Andre; Boczkaj, Grzegorz

    2017-09-29

    The paper presents a new method for the determination of 15 carboxylic acids in samples of postoxidative effluents from the production of petroleum bitumens using ion-pair dispersive liquid-liquid microextraction and gas chromatography coupled to mass spectrometry with injection port derivatization. Several parameters related to the extraction and derivatization efficiency were optimized. Under optimized experimental conditions, the obtained limit of detection and quantification ranged from 0.0069 to 1.12μg/mL and 0.014 to 2.24μg/mL, respectively. The precision (RSD ranged 1.29-6.42%) and recovery (69.43-125.79%) were satisfactory. Nine carboxylic acids at concentrations ranging from 0.10μg/mL to 15.06μg/mL were determined in the raw wastewater and in samples of effluents treated by various oxidation methods. The studies revealed a substantial increase of concentration of benzoic acids, in samples of wastewater after treatment, which confirms the need of carboxylic acids monitoring during industrial effluent treatment processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Simultaneous determination of ascorbic acid and caffeine in commercial soft drinks using reversed-phase ultraperformance liquid chromatography.

    PubMed

    Turak, Fatma; Güzel, Remziye; Dinç, Erdal

    2017-04-01

    A new reversed-phase ultraperformance liquid chromatography method with a photodiode array detector was developed for the quantification of ascorbic acid (AA) and caffeine (CAF) in 11 different commercial drinks consisting of one energy drink and 10 ice tea drinks. Separation of the analyzed AA and CAF with an internal standard, caffeic acid, was performed on a Waters BEH C 18 column (100 mm × 2.1 mm, 1.7 μm i.d.), using a mobile phase consisting of acetonitrile and 0.2M H 3 PO 4 (11:89, v/v) with a flow rate of 0.25 mL/min and an injection volume of 1.0 μL. Calibration graphs for AA and CAF were computed from the peak area ratio of AA/internal standard and CAF/internal standard detected at 244.0 nm and 273.6 nm, respectively. The developed reversed-phase ultraperformance liquid chromatography method was validated by analyzing standard addition samples. The proposed reversed-phase ultraperformance liquid chromatography method gave us successful results for the quantitative analysis of commercial drinks containing AA and CAF substances. Copyright © 2016. Published by Elsevier B.V.

  12. Extracting dielectric fixed charge density on highly doped crystalline-silicon surfaces using photoconductance measurements

    NASA Astrophysics Data System (ADS)

    To, A.; Hoex, B.

    2017-11-01

    A novel method for the extraction of fixed interface charge, Qf, and the surface recombination parameters, Sn0 and Sp0, from the injection-level dependent effective minority carrier lifetime measurements is presented. Unlike conventional capacitance-voltage measurements, this technique can be applied to highly doped surfaces provided the surface carrier concentration transitions into strong depletion or inversion with increased carrier injection. By simulating the injection level dependent Auger-corrected inverse lifetime curve of symmetrically passivated and diffused samples after sequential annealing and corona charging, it was revealed that Qf, Sn0, and Sp0 have unique signatures. Therefore, these important electronic parameters, in some instances, can independently be resolved. Furthermore, it was shown that this non-linear lifetime behaviour is exhibited on both p-type and n-type diffused inverted surfaces, by demonstrating the approach with phosphorous diffused n+pn+ structures and boron diffused p+np+ structures passivated with aluminium oxide (AlOx) and silicon nitride, respectively (SiNx). The results show that the approximation of a mid-gap Shockley-Read-Hall defect level with equal capture cross sections is able to, in the samples studied in this work, reproduce the observed injection level dependent lifetime behaviour.

  13. Flow analysis techniques for phosphorus: an overview.

    PubMed

    Estela, José Manuel; Cerdà, Víctor

    2005-04-15

    A bibliographical review on the implementation and the results obtained in the use of different flow analytical techniques for the determination of phosphorus is carried out. The sources, occurrence and importance of phosphorus together with several aspects regarding the analysis and terminology used in the determination of this element are briefly described. A classification as well as a brief description of the basis, advantages and disadvantages of the different existing flow techniques, namely; segmented flow analysis (SFA), flow injection analysis (FIA), sequential injection analysis (SIA), all injection analysis (AIA), batch injection analysis (BIA), multicommutated FIA (MCFIA), multisyringe FIA (MSFIA) and multipumped FIA (MPFIA) is also carried out. The most relevant manuscripts regarding the analysis of phosphorus by means of flow techniques are herein classified according to the detection instrumental technique used with the aim to facilitate their study and obtain an overall scope. Finally, the analytical characteristics of numerous flow-methods reported in the literature are provided in the form of a table and their applicability to samples with different matrixes, namely water samples (marine, river, estuarine, waste, industrial, drinking, etc.), soils leachates, plant leaves, toothpaste, detergents, foodstuffs (wine, orange juice, milk), biological samples, sugars, fertilizer, hydroponic solutions, soils extracts and cyanobacterial biofilms are tabulated.

  14. Quantitative analysis of the immunosuppressant CP-690,550 in whole blood by column-switching high-performance liquid chromatography and mass spectrometry detection.

    PubMed

    Paniagua, Ricardo; Campbell, Andrew; Changelian, Paul S; Reitz, Bruce A; Prakash, Chandra; Borie, Dominic C

    2005-10-01

    A fast and accurate method to quantify the new immunosuppressive JAK3 inhibitor CP-690,550 in whole blood using a dual-pump liquid chromatography-liquid chromatography-mass spectrometry (LC/LC-MS) system was developed and validated in nonhuman primate blood. Before injection, blood samples were prepared by precipitation with a reagent that included methanol and acetonitrile (30:70, vol/vol) along with the internal standard (CP-istd). Column-switching LC/LC-MS analysis used online extraction followed by separation on a C8 analytic column and MS detection of the [M + H] CP-690,550 (m/z = 313.1) and CP internal standard (m/z = 288.1). Linearity was always better than r = 0.99 (n = 7) for CP-690,550 (range 2.5-750 ng/mL), with a lower limit of quantification (LLOQ) of 2.5 ng/mL. The intrarun accuracy and precision ranged from 103.0% to 105.4% and 2.7% to 4.3%, respectively (n = 5), and the interday precision ranged from 8.7% to 11.1%, and the interday accuracy ranged from 98.1% to 103.8% of nominal values (n = 14). The injection repeatability for the method was 1.3% (n = 7). Except for the LLOQ, the intraday accuracy and precision in human blood were also within 15% (n = 5). The combination of simple sample preparation and short analytic run time of this sensitive procedure makes it effective for monitoring the concentration of CP-690,550 in whole blood in organ-transplant recipients.

  15. Determination of Aristolochic Acid in Botanicals and Dietary Supplements by Liquid Chromatography with Ultraviolet Detection and by Liquid Chromatography/Mass Spectrometry: Single Laboratory Validation Confirmation

    PubMed Central

    Trujillo, William A.; Sorenson, Wendy R.; La Luzerne, Paul; Austad, John W.; Sullivan, Darryl

    2008-01-01

    The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 μg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid Chromatography with ultraviolet detection (LC-UV) and LC/mass Spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 μg/g level, between 102 and 103% at the 10 μg/g level, and 104% at the 30 μg/g level. PMID:16915829

  16. Determination of aristolochic acid in botanicals and dietary supplements by liquid chromatography with ultraviolet detection and by liquid chromatography/mass spectrometry: single laboratory validation confirmation.

    PubMed

    Trujillo, William A; Sorenson, Wendy R; La Luzerne, Paul; Austad, John W; Sullivan, Darryl

    2006-01-01

    The presence of aristolochic acid in some dietary supplements is a concern to regulators and consumers. A method has been developed, by initially using a reference method as a guide, during single laboratory validation (SLV) for the determination of aristolochic acid I, also known as aristolochic acid A, in botanical species and dietary supplements at concentrations of approximately 2 to 32 microg/g. Higher levels were determined by dilution to fit the standard curve. Through the SLV, the method was optimized for quantification by liquid chromatography with ultraviolet detection (LC-UV) and LC/mass spectrometry (MS) confirmation. The test samples were extracted with organic solvent and water, then injected on a reverse phase LC column. Quantification was achieved with linear regression using a laboratory automation system. The SLV study included systematically optimizing the LC-UV method with regard to test sample size, fine grinding of solids, and solvent extraction efficiency. These parameters were varied in increments (and in separate optimization studies), in order to ensure that each parameter was individually studied; the test results include corresponding tables of parameter variations. In addition, the chromatographic conditions were optimized with respect to injection volume and detection wavelength. Precision studies produced overall relative standard deviation values from 2.44 up to 8.26% for aristolochic acid I. Mean recoveries were between 100 and 103% at the 2 microg/g level, between 102 and 103% at the 10 microg/g level, and 104% at the 30 microg/g level.

  17. Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment

    PubMed Central

    Groskreutz, Stephen R.; Weber, Stephen G.

    2016-01-01

    In this work we characterize the development of a method to enhance temperature-assisted on-column solute focusing (TASF) called two-stage TASF. A new instrument was built to implement two-stage TASF consisting of a linear array of three independent, electronically controlled Peltier devices (thermoelectric coolers, TECs). Samples are loaded onto the chromatographic column with the first two TECs, TEC A and TEC B, cold. In the two-stage TASF approach TECs A and B are cooled during injection. TEC A is heated following sample loading. At some time following TEC A’s temperature rise, TEC B’s temperature is increased from the focusing temperature to a temperature matching that of TEC A. Injection bands are focused twice on-column, first on the initial TEC, e.g. single-stage TASF, then refocused on the second, cold TEC. Our goal is to understand the two-stage TASF approach in detail. We have developed a simple yet powerful digital simulation procedure to model the effect of changing temperature in the two focusing zones on retention, band shape and band spreading. The simulation can predict experimental chromatograms resulting from spatial and temporal temperature programs in combination with isocratic and solvent gradient elution. To assess the two-stage TASF method and the accuracy of the simulation well characterized solutes are needed. Thus, retention factors were measured at six temperatures (25–75 °C) at each of twelve mobile phases compositions (0.05–0.60 acetonitrile/water) for homologs of n-alkyl hydroxylbenzoate esters and n-alkyl p-hydroxyphenones. Simulations accurately reflect experimental results in showing that the two-stage approach improves separation quality. For example, two-stage TASF increased sensitivity for a low retention solute by a factor of 2.2 relative to single-stage TASF and 8.8 relative to isothermal conditions using isocratic elution. Gradient elution results for two-stage TASF were more encouraging. Application of two-stage TASF increased peak height for the least retained solute in the test mixture by a factor of 3.2 relative to single-stage TASF and 22.3 compared to isothermal conditions for an injection four-times the column volume. TASF improved resolution and increased peak capacity; for a 12-minute separation peak capacity increased from 75 under isothermal conditions to 146 using single-stage TASF, and 185 for two-stage TASF. PMID:27836226

  18. Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment.

    PubMed

    Groskreutz, Stephen R; Weber, Stephen G

    2016-11-25

    In this work we characterize the development of a method to enhance temperature-assisted on-column solute focusing (TASF) called two-stage TASF. A new instrument was built to implement two-stage TASF consisting of a linear array of three independent, electronically controlled Peltier devices (thermoelectric coolers, TECs). Samples are loaded onto the chromatographic column with the first two TECs, TEC A and TEC B, cold. In the two-stage TASF approach TECs A and B are cooled during injection. TEC A is heated following sample loading. At some time following TEC A's temperature rise, TEC B's temperature is increased from the focusing temperature to a temperature matching that of TEC A. Injection bands are focused twice on-column, first on the initial TEC, e.g. single-stage TASF, then refocused on the second, cold TEC. Our goal is to understand the two-stage TASF approach in detail. We have developed a simple yet powerful digital simulation procedure to model the effect of changing temperature in the two focusing zones on retention, band shape and band spreading. The simulation can predict experimental chromatograms resulting from spatial and temporal temperature programs in combination with isocratic and solvent gradient elution. To assess the two-stage TASF method and the accuracy of the simulation well characterized solutes are needed. Thus, retention factors were measured at six temperatures (25-75°C) at each of twelve mobile phases compositions (0.05-0.60 acetonitrile/water) for homologs of n-alkyl hydroxylbenzoate esters and n-alkyl p-hydroxyphenones. Simulations accurately reflect experimental results in showing that the two-stage approach improves separation quality. For example, two-stage TASF increased sensitivity for a low retention solute by a factor of 2.2 relative to single-stage TASF and 8.8 relative to isothermal conditions using isocratic elution. Gradient elution results for two-stage TASF were more encouraging. Application of two-stage TASF increased peak height for the least retained solute in the test mixture by a factor of 3.2 relative to single-stage TASF and 22.3 compared to isothermal conditions for an injection four-times the column volume. TASF improved resolution and increased peak capacity; for a 12-min separation peak capacity increased from 75 under isothermal conditions to 146 using single-stage TASF, and 185 for two-stage TASF. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Preparation of 99Tcm-MAG3: no confirmation that sodium chloride injections from plastic containers affect radiochemical purity.

    PubMed

    Millar, A M; O'Brien, L M

    1998-05-01

    Reports have suggested that when sodium chloride injections from a plastic ampoule are used during the preparation of 99Tcm-mercaptoacetyltriglycine (99Tcm-MAG3), the radiochemical purity of the final product might be reduced. A study was therefore undertaken to examine the effect of sodium chloride injections from five manufacturers on the radiochemical purity and stability of 99Tcm-MAG3. One sodium chloride injection was supplied in a glass vial, three in plastic ampoules and one in a plastic infusion bag. Three batches of sodium chloride injections from each manufacturer were tested. The radiopharmaceutical was prepared at a radioactive concentration of 1.1 GBq in 10 ml according to the instructions of the manufacturer of TechneScan MAG3. Analysis of radiochemical purity was performed by high-performance liquid chromatography immediately after preparation and 6 h later. Using 95% as the minimum acceptable radiochemical purity, all the products were satisfactory over the 6 h test period. No manufacturer's sodium chloride injection was found to have a statistically significant effect on the radiochemical purity. Based on the 15 batches of sodium chloride injection tested, this study cannot confirm that sodium chloride injections from a plastic container affect the radiochemical purity of 99Tcm-MAG3. However, in view of the known sensitivity of some 99Tcm radiopharmaceuticals to external influences, it is probably good practice to test radiochemical purity when new batches of ancillary materials, such as sodium chloride injections, are introduced.

  20. Effects of 5,7-DHT Injection into the Optic Lobe on the Circadian Locomotor Rhythm in the Cricket, Gryllus bimaculatus.

    PubMed

    Germ, M; Tomioka, K

    1998-06-01

    The effect of direct 5,7-dihydroxytryptamine (5,7-DHT) injection into the medulla region of the optic lobe on the locomotor activity was investigated in the adult male cricket, Gryllus bimaculatus. After a 6 hr phase advance of a light-dark cycle, the 5,7-DHT injected animals needed significantly longer time for resynchronization to the new cycle (6.55 +/- 0.62 days) than the control, Ringer's solution injected animals (3.17 +/- 0.15 days; P < 0.001, t-test). Light induced a bout of activity (i.e., masking effect) when light-dark cycle was phase advanced by 6 hr and the duration of the masking effect was significantly longer in 5,7-DHT injected animals. An initial bout of the nocturnal activity was significantly greater in the 5,7-DHT injected animal. Under constant darkness, the freerunning periods of both groups were not significantly different. Under constant light, a significantly higher percentage of 5,7-DHT injected animals showed arrhythmicity compared with the control group. An analysis carried by high-pressure liquid chromatography with electro-chemical detection (HPLC-ECD) revealed that the serotonin content in the optic lobe was significantly reduced to less than 50% in the 5,7-DHT injected animals, even one month after the injection. These results suggest that serotonin plays important roles in the regulation of circadian locomotor rhythms of the cricket mainly by regulating the sensitivity of the photoreceptive system.

  1. Comprehensive two-dimensional chromatography with coupling of reversed phase high performance liquid chromatography and supercritical fluid chromatography.

    PubMed

    Stevenson, Paul G; Tarafder, Abhijit; Guiochon, Georges

    2012-01-13

    A 2D comprehensive chromatographic separation of blackberry sage fragrant oil was performed by using HPLC in the first dimension and SFC in the second. A C(18)-bonded silica column eluted with an ACN gradient was used in the HPLC dimension and an amino-bonded silica column eluted with ACN as a modifier in the SFC dimension. This 2D separation was completed in the off-line mode, the fractions from the HPLC column being collected and injected in the SFC column. The retention factors on the two columns have a -0.757 correlation coefficient. The method provides a practical peak capacity of 2400 in 280 min. The first eluted peaks in HPLC are the last ones eluted in SFC and vice versa. The results demonstrate that the coupling of an HPLC and an SFC separation have a great potential for 2D chromatographic separations. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Qian, Michael C.

    Gas chromatography (GC) has many applications in the analysis of food products. GC has been used for the determination of fatty acids, triglycerides, cholesterol, gases, water, alcohols, pesticides, flavor compounds, and many more. While GC has been used for other food components such as sugars, oligosaccharides, amino acids, peptides, and vitamins, these substances are more suited to analysis by high performance liquid chromatography. GC is ideally suited to the analysis of volatile substances that are thermally stable. Substances such as pesticides and flavor compounds that meet these criteria can be isolated from a food and directly injected into the GC. For compounds that are thermally unstable, too low in volatility, or yield poor chromatographic separation due to polarity, a derivatization step must be done before GC analysis. The two parts of the experiment described here include the analysis of alcohols that requires no derivatization step, and the analysis of fatty acids which requires derivatization. The experiments specify the use of capillary columns, but the first experiment includes conditions for a packed column.

  3. Neuropeptide-Y both Improves and Impairs Delayed Matching-to-Sample Performance in Rats

    DTIC Science & Technology

    1991-01-01

    Neuropeptide Y distribution in the 422 THOMAS AND AHLERS rat brain. Science 221:877-879; 1983. of animal learning. In: Roitblat , H. L.; Bever, T. G.; Terrace, H...Sources of proactive interference in memory. Hillsdale, NJ: Erlbaum; 1976. animal memory. J. Exp. Psychol. (Anim. Behav.) 1456-70; 1988. 32. Roitblat , H...memory processing by neuropeptide Y varies with brain 33. Roitblat , H. L., Scopatz, R. A. Sequential effects in pigeons de- injection site. Brain Res

  4. Direct probing of chromatography columns by laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    McGuffin, V. L.

    1992-12-01

    This report summarizes the progress and accomplishments of this research project from 1 Sep. 1989 to 28 Feb. 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe in supercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  5. Early detection of osteoarthritis in rabbits using MRI with a double-contrast agent.

    PubMed

    Onishi, Okihiro; Ikoma, Kazuya; Kido, Masamitsu; Kabuto, Yukichi; Ueshima, Keiichiro; Matsuda, Ken-Ichi; Tanaka, Masaki; Kubo, Toshikazu

    2018-03-13

    Articular cartilage degeneration has been evaluated by magnetic resonance imaging (MRI). However, this method has several problems, including its time-consuming nature and the requirement of a high magnetic field or specialized hardware. The purpose of this study was to sequentially assess early degenerative changes in rabbit knee articular cartilage using MRI with a new double-contrast agent. We induced osteoarthritis (OA) in the right knee of rabbits by anterior cruciate ligament transection and partial medial meniscectomy. Proton density-weighted images and T 2 -calculated images were obtained before and after contrast agent injection into the knee. The signal intensity ratio (SIR) values on the proton density-weighted images were calculated by dividing the signal intensity of the articular cartilage by that of joint fluid. Six rabbits were examined using MRI at 2 (designated 2-w OA) and 4 weeks (4-w OA) after the operation. Histological examination was performed 4 weeks after the operation. One rabbit was histologically examined 2 weeks after the operation. The control consisted of six rabbits that were not subjected to the operation. The SIR values, T 2 values and the thicknesses of the cartilage of the 2-w OA, 4-w OA and the control before and after contrast agent injection were analyzed. The Mankin score and OARSI (Osteoarthritis Research Society International) score were used for the histological evaluation. Significant differences in the SIR and T 2 values of the medial and lateral condyles of the femur were found between the control and the 4-w OA only after contrast agent injection. No significant differences were found in the SIR and T 2 values before contrast agent injection between the control, the 2-w OA and 4-w OA. The thickness of the articular cartilage revealed no significant differences. In the histological assessment, the Mankin score and OARSI score sequentially increased from the control to the 4-w OA. We evaluated the SIR and T 2 values of the knees in a rabbit OA model and a control model using a new double-contrast agent. MRI with this agent enabled OA detection earlier than using conventional MRI.

  6. Suppression of linalool acetate production in Lavandula x intermedia.

    PubMed

    Desautels, Amy; Biswas, Kamal; Lane, Alexander; Boeckelmann, Astrid; Mahmoud, Soheil S

    2009-11-01

    Linalool acetate, one of the major constituent of several essential oils, is heat-labile and decomposes upon exposure to the high injector temperature during gas chromatography. Here we report the development of an improved method for detection of this compound by gas chromatography mass spectrometry (GCMS) using cold on-column injection of the sample. By using this sensitive method, it has been demonstrated that a lavandin (L. x intermedia) mutant accumulates trace quantities of linalool acetate and camphor and higher amounts of cineole and borneol compared to its parent. This plant, which very likely carries a point mutation in one or more of the genes involved in essential oil production, provides a unique tool for investigating regulation of essential oil biogenesis in plants.

  7. In situ ionic liquid dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry for the determination of organophosphorus pesticides.

    PubMed

    Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M

    2018-07-20

    Nine organophosphorus pesticides (OPPs) were determined in environmental waters from different origins using in situ ionic liquid dispersive liquid microextraction (IL-DLLME). This preconcentration technique was coupled to gas chromatography-mass spectrometry (GC-MS) using microvial insert thermal desorption, an approach that uses a thermal desorption injector as sample introduction system. The parameters affecting both the microextraction and sample injection steps were optimized. The proposed method showed good precision, with RSD values ranging from 4.1 to 9.7%, accuracy with recoveries in the 85-118% range, and sensitivity with DLs ranging from 5 to 16 ng L -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Serotonin syndrome following sibutramine poisoning in a child, with sequential quantification of sibutramine and its primary and secondary amine metabolites in plasma.

    PubMed

    Bucaretchi, Fábio; de Capitani, Eduardo Mello; Mello, Sueli Moreira; Lanaro, Rafael; Barros, Roberta F; Fernandes, Luciane C R; da Costa, José Luiz; Hyslop, Stephen

    2009-07-01

    To report a case of serotonin syndrome (SS) after sibutramine overdose in a child. A 4-year-old girl was admitted 25 h after accidentally ingesting approximately 27 pills of sibutramine (15 mg, approximately 23 mg/kg). The child developed clinical features suggestive of SS, including diaphoresis, tachycardia, hypertension, agitation, insomnia, incoordination, hypertonia (lower limbs > upper limbs), and hallucinations. Serum creatine phosphokinase levels reached a peak on day 3 (2,577 U/L, reference value <145), suggesting mild rhabdomyolysis. No relevant changes were detected in other laboratory examinations or in the electrocardiogram throughout the period of hospitalization. The quantification of sibutramine and the active metabolites, M1 (mono-desmethyl sibutramine) and M2 (di-desmethyl sibutramine), by liquid chromatography/electrospray ionization tandem mass spectrometry in six sequential samples collected from 25 to 147 h post-ingestion revealed a nonlinear decrease in the log-scale plasma concentrations. Treatment was only supportive and involved prolonged sedation to control the agitation, sleeplessness, and hypertension; no cyproheptadine was used. The patient was discharged on day 6 and follow-up revealed no sequelae. To our knowledge, this is the first report of SS after sibutramine overdose in a child, with sequential monitoring of the plasma levels of the drug and its two active metabolites. The growing consumption of weight reducing pills may increase the risk of unintentional acute toxic exposures in children.

  9. Comparison of two methods for purification of enterocin B, a bacteriocin produced by Enterococcus faecium W3.

    PubMed

    Dündar, Halil; Atakay, Mehmet; Çelikbıçak, Ömür; Salih, Bekir; Bozoğlu, Faruk

    2015-01-01

    This study aimed to compare two different approaches for the purification of enterocin B from Enterococcus faecium strain W3 based on the observation that the bacteriocin was found both in cell associated form and in culture supernatant. The first approach employed ammonium sulfate precipitation, cation-exchange chromatography, and sequential reverse-phase high-performance liquid chromatography. The latter approach exploited a pH-mediated cell adsorption-desorption method to extract cell-bound bacteriocin, and one run of reverse-phase chromatography. The first method resulted in purification of enterocin B with a recovery of 4% of the initial bacteriocin activity found in culture supernatant. MALDI-TOF MS analysis and de novo peptide sequencing of the purified bacteriocin confirmed that the active peptide was enterocin B. The second method achieved the purification of enterocin B with a higher recovery (16%) and enabled us to achieve pure bacteriocin within a shorter period of time by avoiding time consuming purification protocols. The purity and identity of the active peptide were confirmed again by matrix-assisted laser desorption/ionization time-of flight (MALDI-TOF) mass spectrometry (MS) analysis. Although both approaches were satisfactory to obtain a sufficient amount of enterocin B for use in MS and amino acid sequence analysis, the latter was proved to be applicable in large-scale and rapid purification of enterocin B.

  10. Influence of sodium carbonate on decomposition of formic acid by pulsed discharge plasma inside bubble in water

    NASA Astrophysics Data System (ADS)

    Iwabuchi, Masashi; Takahashi, Katsuyuki; Takaki, Koichi; Satta, Naoya

    2016-07-01

    The influence of sodium carbonate on the decomposition of formic acid by discharge inside bubbles in water was investigated experimentally. Oxygen or argon gases were injected into the water through a vertically positioned glass tube, in which the high-voltage wire electrode was placed to generate plasmas at low applied voltage. The concentration of formic acid was determined by ion chromatography. In the case of sodium carbonate additive, the pH increased owing to the decomposition of the formic acid. In the case of oxygen injection, the percentage of conversion of formic acid increased with increasing pH because the reaction rate of ozone with formic acid increased with increasing pH. In the case of argon injection, the percentage of conversion was not affected by the pH owing to the high rate loss of hydroxyl radicals.

  11. Computational fluid dynamics study of viscous fingering in supercritical fluid chromatography.

    PubMed

    Subraveti, Sai Gokul; Nikrityuk, Petr; Rajendran, Arvind

    2018-01-26

    Axi-symmetric numerical simulations are carried out to study the dynamics of a plug introduced through a mixed-stream injection in supercritical fluid chromatographic columns. The computational fluid dynamics model developed in this work takes into account both the hydrodynamics and adsorption equilibria to describe the phenomena of viscous fingering and plug effect that contribute to peak distortions in mixed-stream injections. The model was implemented into commercial computational fluid dynamics software using user-defined functions. The simulations describe the propagation of both the solute and modifier highlighting the interplay between the hydrodynamics and plug effect. The simulated peaks showed good agreement with experimental data published in the literature involving different injection volumes (5 μL, 50 μL, 1 mL and 2 mL) of flurbiprofen on Chiralpak AD-H column using a mobile phase of CO 2 and methanol. The study demonstrates that while viscous fingering is the main source of peak distortions for large-volume injections (1 mL and 2 mL) it has negligible impact on small-volume injections (5 μL and 50 μL). Band broadening in small-volume injections arise mainly due to the plug effect. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  12. Barley as a green factory for the production of functional Flt3 ligand.

    PubMed

    Erlendsson, Lýdur S; Muench, Marcus O; Hellman, Ulf; Hrafnkelsdóttir, Soffía M; Jonsson, Anders; Balmer, Yves; Mäntylä, Einar; Orvar, Björn L

    2010-02-01

    Biologically active recombinant human Flt3 ligand was expressed and isolated from transgenic barley seeds. Its expression is controlled by a tissue specific promoter that confines accumulation of the recombinant protein to the endosperm tissue of the seed. The recombinant Flt3 ligand variant expressed in the seeds contains an HQ-tag for affinity purification on immobilized metal ion affinity chromatography (IMAC) resin. The tagged protein was purified from seed extracts to near homogeneity using sequential chromatography on IMAC affinity resin and cation exchange resin. We also show that the recombinant Flt3 ligand protein undergoes posttranslational modifications: it is a glycoprotein containing alpha-1,3-fucose and alpha-1,2-xylose. The HQ-tagged Flt3 ligand variant exhibits comparable biological activity to commercial Flt3 ligand. This is the first report showing expression and accumulation of recombinant human growth factor in barley seeds with a yield of active protein similar to a bacterial expression system. The present results demonstrate that plant molecular farming is a viable approach for the bioproduction of human-derived growth factors.

  13. High-performance liquid chromatography-mass spectrometry-based acetylcholinesterase assay for the screening of inhibitors in natural extracts.

    PubMed

    de Jong, Camiel F; Derks, Rico J E; Bruyneel, Ben; Niessen, Wilfried; Irth, Hubertus

    2006-04-21

    The present paper describes a High-performance liquid chromatography-mass spectrometry (LC-MS) methodology for the screening of acetylcholinesterase (AChE) inhibitors in natural extracts. AChE activity of sample components is monitored by a post-column biochemical assay that is based on the separate, sequential mixing of AChE and acetylcholine, respectively, with the HPLC eluate. AChE inhibitors are detected by measuring a decrease of product formation using electrospray MS. Ammonium bicarbonate was used as buffer in order to achieve optimum compatibility between biochemical assay and MS detection conditions. The assay is robust and stable for over 13 h and compares favourably with other AChE assays in terms of stability and sensitivity. IC(50) values of 9-aminoacridine, galanthamine, gallamine, (-)-huperzine A and thioflavin T were determined to be 0.12, 0.38, 6.4, 0.46 and 3.2 microM, respectively. The assay was used to effectively identify an AChE inhibitor present in a crude extract of Narcissus c.v. "Bridal Crown".

  14. Neanderthal medics? Evidence for food, cooking, and medicinal plants entrapped in dental calculus

    NASA Astrophysics Data System (ADS)

    Hardy, Karen; Buckley, Stephen; Collins, Matthew J.; Estalrrich, Almudena; Brothwell, Don; Copeland, Les; García-Tabernero, Antonio; García-Vargas, Samuel; de la Rasilla, Marco; Lalueza-Fox, Carles; Huguet, Rosa; Bastir, Markus; Santamaría, David; Madella, Marco; Wilson, Julie; Cortés, Ángel Fernández; Rosas, Antonio

    2012-08-01

    Neanderthals disappeared sometime between 30,000 and 24,000 years ago. Until recently, Neanderthals were understood to have been predominantly meat-eaters; however, a growing body of evidence suggests their diet also included plants. We present the results of a study, in which sequential thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) and pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) were combined with morphological analysis of plant microfossils, to identify material entrapped in dental calculus from five Neanderthal individuals from the north Spanish site of El Sidrón. Our results provide the first molecular evidence for inhalation of wood-fire smoke and bitumen or oil shale and ingestion of a range of cooked plant foods. We also offer the first evidence for the use of medicinal plants by a Neanderthal individual. The varied use of plants that we have identified suggests that the Neanderthal occupants of El Sidrón had a sophisticated knowledge of their natural surroundings which included the ability to select and use certain plants.

  15. Neanderthal medics? Evidence for food, cooking, and medicinal plants entrapped in dental calculus.

    PubMed

    Hardy, Karen; Buckley, Stephen; Collins, Matthew J; Estalrrich, Almudena; Brothwell, Don; Copeland, Les; García-Tabernero, Antonio; García-Vargas, Samuel; de la Rasilla, Marco; Lalueza-Fox, Carles; Huguet, Rosa; Bastir, Markus; Santamaría, David; Madella, Marco; Wilson, Julie; Cortés, Angel Fernández; Rosas, Antonio

    2012-08-01

    Neanderthals disappeared sometime between 30,000 and 24,000 years ago. Until recently, Neanderthals were understood to have been predominantly meat-eaters; however, a growing body of evidence suggests their diet also included plants. We present the results of a study, in which sequential thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) and pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) were combined with morphological analysis of plant microfossils, to identify material entrapped in dental calculus from five Neanderthal individuals from the north Spanish site of El Sidrón. Our results provide the first molecular evidence for inhalation of wood-fire smoke and bitumen or oil shale and ingestion of a range of cooked plant foods. We also offer the first evidence for the use of medicinal plants by a Neanderthal individual. The varied use of plants that we have identified suggests that the Neanderthal occupants of El Sidrón had a sophisticated knowledge of their natural surroundings which included the ability to select and use certain plants.

  16. Mineral oil barrier sequential polymer treatment for recycled paper products in food packaging

    NASA Astrophysics Data System (ADS)

    Paul, Uttam C.; Fragouli, Despina; Bayer, Ilker S.; Mele, Elisa; Conchione, Chiara; Cingolani, Roberto; Moret, Sabrina; Athanassiou, Athanassia

    2017-01-01

    Recycled cellulosic paperboards may include mineral oils after the recycle process, which together with their poor water resistance limit their use as food packaging materials. In this work, we demonstrate that a proper functionalization of the recycled paper with two successive polymer treatments, imposes a mineral oil migration barrier and simultaneously renders it waterproof and grease resistant, making it an ideal material for food contact. The first poly (methyl methacrylate) treatment penetrates the paper network and creates a protective layer around every fiber, permitting thus the transformation of the paperboard to a hydrophobic material throughout its thickness, reducing at the same time the mineral oil migration. Subsequently, the second layer with a cyclic olefin copolymer fills the open pores of the surface, and reduces the mineral oil hydrocarbons migration at levels below those proposed by the BMEL. Online liquid chromatography-gas chromatography coupled with flame ionization detection quantitatively demonstrate that this dual functional treatment prevents the migration of both saturated (mineral oil saturated hydrocarbons) and aromatic hydrocarbon (mineral oil aromatic hydrocarbons) mineral oils from the recycled paperboard to a dry food simulant.

  17. Radiochemical determination of 241Am and Pu(alpha) in environmental materials.

    PubMed

    Warwick, P E; Croudace, I W; Oh, J S

    2001-07-15

    Americium-241 and plutonium determinations will become of greater importance over the coming decades as 137Cs and 241Pu decay. The impact of 137Cs on environmental chronology has been great, but its potency is waning as it decays and diffuses. Having 241Am and Pu as unequivocal markers for the 1963 weapon fallout maximum is important for short time scale environmental work, but a fast and reliable procedure is required for their separation. The developed method described here begins by digesting samples using a lithium borate fusion although an aqua regia leachate is also effective in many instances. Isolation of the Am and Pu is then achieved using a combination of extraction chromatography and conventional anion exchange chromatography. The whole procedure has been optimized, validated, and assessed for safety. The straightforwardness of this technique permits the analysis of large numbers of samples and makes 241Am-based techniques for high-resolution sediment accumulation rate studies attractive. In addition, the technique can be employed for the sequential measurement of Pu and Am in environmental surveillance programs, potentially reducing analytical costs and turnround times.

  18. Simplex optimization of headspace factors for headspace gas chromatography determination of residual solvents in pharmaceutical products.

    PubMed

    Grodowska, Katarzyna; Parczewski, Andrzej

    2013-01-01

    The purpose of the present work was to find optimum conditions of headspace gas chromatography (HS-GC) determination of residual solvents which usually appear in pharmaceutical products. Two groups of solvents were taken into account in the present examination. Group I consisted of isopropanol, n-propanol, isobutanol, n-butanol and 1,4-dioxane and group II included cyclohexane, n-hexane and n-heptane. The members of the groups were selected in previous investigations in which experimental design and chemometric methods were applied. Four factors were taken into consideration in optimization which describe HS conditions: sample volume, equilibration time, equilibrium temperature and NaCl concentration in a sample. The relative GC peak area served as an optimization criterion which was considered separately for each analyte. Sequential variable size simplex optimization strategy was used and the progress of optimization was traced and visualized in various ways simultaneously. The optimum HS conditions appeared different for the groups of solvents tested, which proves that influence of experimental conditions (factors) depends on analyte properties. The optimization resulted in significant signal increase (from seven to fifteen times).

  19. Characterization of solid-phase microextraction and gas chromatography for the analysis of gasoline tracers in different microenvironments.

    PubMed

    Ceballos, Diana; Zielinska, Barbara; Fujita, Eric; Sagebiel, John

    2007-03-01

    Gasoline tracers were collected on solid-phase microextraction (SPME) fibers and analyzed by capillary gas chromatography with photoionization detector (GC/PID). This was part of a larger study to quantify personal exposure to motor vehicle gasoline evaporative and combustive emissions in high-end exposure microenvironments (MEs). The SPME fiber selected for this application was a 75-microm carboxen/polydimethylsiloxane. Sequential 10-min samples were collected for measurement of benzene, toluene, ethylbenzene, and ortho-, meta-, and para-xylene in different MEs in Atlanta, GA, in summer 2002 and Reno, NV, in spring 2003. Field calibrations were performed with certified gas standards in 1-L Tedlar bags for varying concentrations and exposure times. SPME detection limits were approximately 0.2 ppbv with a precision of 3-17% and accuracy of 30%. A dynamic system was designed for temperature and relative humidity calibrations, with corrections for the effects of these variables performed when necessary. SPME data compared satisfactorily with integrated canister samples, continuous PID, and field portable mass spectrometer data.

  20. Structural characterization of hemicelluloses and topochemical changes in Eucalyptus cell wall during alkali ethanol treatment.

    PubMed

    Li, Han-Yin; Sun, Shao-Ni; Zhou, Xia; Peng, Feng; Sun, Run-Cang

    2015-06-05

    Eucalyptus was sequentially extracted with 70% ethanol containing 0.4, 1.0, 2.0, 3.0, and 5.0% NaOH for 2h at 80°C. The chemical composition and structural features of the hemicellulosic fractions obtained were comparatively characterized by the combination of high-performance anion-exchange chromatography, gel permeation chromatography, Fourier transform infrared, and nuclear magnetic resonance spectroscopies. Furthermore, the main component distribution and their changes in cell wall were investigated by confocal Raman microscopy. Based on the Fourier transform infrared and nuclear magnetic resonance analyses, the hemicelluloses extracted from Eucalyptus mainly have a linear backbone of (1→4)-linked-β-d-xylopyranosyl residues decorated with branch at O-2 of 4-O-methyl-α-glucuronic acid unit. Raman analysis revealed that the dissolution of hemicelluloses was different in the morphological regions, and the hemicelluloses released mainly originated from the secondary wall. The information obtained from the study conducted by combining chemical characterization with ultrastructure provides important basis for studying the mechanism of the alkali treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Improved Quantitation of Gluten in Wheat Starch for Celiac Disease Patients by Gel-Permeation High-Performance Liquid Chromatography with Fluorescence Detection (GP-HPLC-FLD).

    PubMed

    Scherf, Katharina Anne; Wieser, Herbert; Koehler, Peter

    2016-10-12

    Purified wheat starch (WSt) is commonly used in gluten-free products for celiac disease (CD) patients. It is mostly well-tolerated, but doubts about its safety for CD patients persist. One reason may be that most ELISA kits primarily recognize the alcohol-soluble gliadin fraction of gluten, but insufficiently target the alcohol-insoluble glutenin fraction. To address this problem, a new sensitive method based on the sequential extraction of gliadins, glutenins, and gluten from WSt followed by gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD) was developed. It revealed that considerable amounts of glutenins were present in most WSt. The gluten contents quantitated by GP-HPLC-FLD as sum of gliadins and glutenins were higher than those by R5 ELISA (gluten as gliadin content multiplied by a factor of 2) in 19 out of 26 WSt. Despite its limited selectivity, GP-HPLC-FLD may be applied as confirmatory method to ELISA to quantitate gluten in WSt.

  2. Rapid purification of staphylococcal enterotoxin B by high-pressure liquid chromatography.

    PubMed Central

    Strickler, M P; Neill, R J; Stone, M J; Hunt, R E; Brinkley, W; Gemski, P

    1989-01-01

    The Staphylococcus aureus enterotoxins represent a group of proteins that cause emesis and diarrhea in humans and other primates. We have developed a rapid two-step high-pressure liquid chromatography (HPLC) procedure for purification of staphylococcal enterotoxin B (SEB). Sterile filtrates (2.5 liters) of strain 10-275 were adsorbed directly onto a reversed-phase column (50 mm by 30 cm Delta Pak; 300 A [30 nm], 15 microns, C18). SEB was obtained by using a unique sequential gradient system. First, an aqueous ammonium acetate to acetonitrile gradient followed by an aqueous trifluoroacetic acid (TFA) wash was used to remove contaminants. A subsequent TFA to acetonitrile-TFA gradient eluted the bound SEB. Further purification was obtained by rechromatography on a cation-exchange column. From 35 to 45% of the SEB in starting filtrates was recovered. Analysis by immunoblotting of samples separated on sodium dodecyl sulfate-polyacrylamide gels indicated that HPLC-purified SEB exhibited immunological and biochemical properties similar to those of the SEB standard. Induction of an emetic response in rhesus monkeys showed that the HPLC-purified toxin also retained biological activity. Images PMID:2745678

  3. Purification and partial characterization of a novel antibacterial agent (Bac1829) Produced by Staphylococcus aureus KSI1829.

    PubMed Central

    Crupper, S S; Iandolo, J J

    1996-01-01

    A novel antimicrobial agent from Staphylococcus aureus KSI1829, designated Bac1829, was purified by sequential steps of ammonium sulfate precipitation, Sephadex G-50 gel filtration chromatography, and hydrophobic interaction chromatography. Purified Bac1829 has a molecular mass of 6,418 +/- 2 Da. The peptide in heat stable, since full biological activity is retained after heating at 95 degrees C for 15 min, and it is destroyed by digestion with proteases. Amino acid sequence analysis revealed a high concentration of Ala and Gly residues, which respectively comprised 24 and 19% of the total amino acid content. Additionally, high levels of hydrophobic amino acids were present, accounting for the hydrophobic nature of Bac1829. Purified Bac1829 killed exponentially growing Corynebacterium renale in a dose-dependent manner by a bactericidal mode of action. A partial inhibitory spectrum analysis revealed that the following organisms were sensitive to the inhibitory activity of Bac1829: S. aureus RN4220, Streptococcus suis, Corynebacterium pseudotuberculosis, C. renale, Corynebacterium diptheriae, Haemophilus parasuis, Bordetella pertussis, Bordetella bronchoseptica, Moraxella bovis, and Pasteurella multocida. PMID:8795206

  4. Comparison of Periodontal Ligament Injection and Inferior Alveolar Nerve Block in Mandibular Primary Molars Pulpotomy: A Randomized Control Trial

    PubMed Central

    Haghgoo, Roza; Taleghani, Ferial

    2015-01-01

    Background: Inferior alveolar nerve block is a common technique for anesthesia of the primary mandibular molars. A number of disadvantages have been shown to be associated with this technique. Periodontal ligament (PDL) injection could be considered as an alternative to inferior alveolar nerve block. The aim of this study was to evaluate the effectiveness of PDL injection in the anesthesia of primary molar pulpotomy with mandibular block. Methods: This study was performed using a sequential double-blind randomized trial design. 80 children aged 3-7 years old who required pulpotomy in symmetrical mandibular primary molars were selected. The teeth of these children were anesthetized with periodontal injection on one side of the mandible and block on the other. Pulpotomy was performed on each patient during the same appointment. Signs of discomfort, including hand and body tension and eye movement, the verbal complaint and crying (SEM scale), were evaluated by a dental assistant who was blinded to the treatment allocation of the patients. Finally, the data were analyzed using the exact Fisher test and Pearson Chi-squared exact test. Results: Success rate was 88/75 and 91/25 in the PDL injection and nerve block groups, respectively. There was no statistically significant difference between the two techniques (P = 0.250). Conclusion: Results showed that PDL injection can be used as an alternative to nerve block in pulpotomy of the mandibular primary molars. PMID:26028895

  5. Sequential Actions of Rab5 and Rab7 Regulate Endocytosis in the Xenopus Oocyte

    PubMed Central

    Mukhopadhyay, Amitabha; Barbieri, Alejandro M.; Funato, Kouichi; Roberts, Richard; Stahl, Philip D.

    1997-01-01

    To explore the role of GTPases in endocytosis, we developed an assay using Xenopus oocytes injected with recombinant proteins to follow the uptake of the fluid phase marker HRP. HRP uptake was inhibited in cells injected with GTPγS or incubated with aluminum fluoride, suggesting a general role for GTPases in endocytosis. Injection of Rab5 into oocytes, as well as Rab5:Q79L, a mutant with decreased GTPase activity, increased HRP uptake. Injection of Rab5:S34N, the dominant-negative mutant, inhibited HRP uptake. Injection of N-ethylmaleimide–sensitive factor (NSF) stimulated HRP uptake, and ATPase-defective NSF mutants inhibited HRP uptake when coinjected with Rab5:Q79L, confirming a requirement for NSF in endocytosis. Surprisingly, injection of Rab7:WT stimulated both uptake and degradation/activation of HRP. The latter appears to be due to enhanced transport to a late endosomal/prelysosomal degradative compartment that is monensin sensitive. Enhancement of uptake by Rab7 appears to function via an Rab5-sensitive pathway in oocytes since the stimulatory effect of Rab7 was blocked by coinjection of Rab5:S34N. Stimulation of uptake by Rab5 was blocked by Rab5:S34N but not by Rab7:T22N. Our results suggest that Rab7, while functioning downstream of Rab5, may be rate limiting for endocytosis in oocytes. PMID:9087439

  6. Modular separation-based fiber-optic sensors for remote in situ monitoring.

    PubMed

    Dickens, J; Sepaniak, M

    2000-02-01

    A modular separation-based fiber-optic sensor (SBFOS) with an integrated electronically controlled injection device is described for potential use in remote environmental monitoring. An SBFOS is a chemical monitor that integrates the separation selectivity and versatility afforded by capillary electrophoresis with the remote and high sensitivity capabilities of fiber-optic-based laser-induced fluorescence sensing. The detection module of the SBFOS accommodates all essential sensing components for dual-optical fiber, on-capillary fluorescence detection. An injection module, similar to injection platforms on micro-analysis chips, is also integrated to the SBFOS. The injection module allows for electronically controlled injection of the sample onto the separation capillary. The design and operational characteristics of the modular SBFOS are discussed in this paper. A micellar electrokinetic capillary chromatography mode of separation is employed to evaluate the potential of the sensor for in situ monitoring of neutral toxins (aflatoxins). The analytical figures of merit for the modular SBFOS include analysis times of between 5 and 10 min, separation efficiencies of approximately 10(4) theoretical plates, detection limits for aflatoxins in the mid-to-low nanomolar range, and controllable operation that results in sensor performance that is largely immune to sample matrix effects.

  7. Testing a fall risk model for injection drug users.

    PubMed

    Pieper, Barbara; Templin, Thomas N; Goldberg, Allon

    2012-01-01

    Fall risk is a critical component of clinical assessment and has not been examined for persons who have injected illicit drugs and are aging. The aim of this study was to test and develop the Fall Risk Model for Injection Drug Users by examining the relationships among injection drug use, chronic venous insufficiency, lower extremity impairments (i.e., decreased ankle range of motion, reduced calf muscle endurance, and leg pain), age and other covariates, and the Tinetti balance and gait total score as a measure of fall risk. A cross-sectional comparative design was used with four crossed factors. Standardized instruments were used to assess the variables. Moderated multiple regression with linear and quadratic trends in age was used to examine the nature of the relationship between the Tinetti balance and gait total and age and the potential moderating role of injection drug use. A prespecified series of models was tested. Participants (n = 713) were men (46.9%) and women with a mean age of 46.26 years and primarily African American (61.7%) in methadone treatment centers. The fall risk of a 48-year-old leg injector was comparable with the fall risk of a 69-year-old who had not injected drugs. Variables were added to the model sequentially, resulting in some lost significance of some when they were explained by subsequent variables. Final significant variables in the model were employment status, number of comorbidities, ankle range of motion, leg pain, and calf muscle endurance. Fall risk was associated with route of drug use. Lower extremity impairments accounted for the effects of injection drug use and chronic venous insufficiency on risk for falls. Further understanding of fall risk in injection users is necessary as they age, attempt to work, and participate in activities.

  8. Measurement of imidacloprid in xylem fluid from eastern hemlock (Tsuga canadensis) by derivitization/GC/MS and ELISA

    Treesearch

    Anthony Lagalante; Peter Greenbacker; Jonathan Jones; Richard Turcotte; Bradley Onken

    2007-01-01

    Imidacloprid is a nonvolatile insecticide and its direct quantification is not possible by gas chromatography. In order to ascertain imidacloprid levels in soil and trunk injection treated trees, a sensitive and selective method has been developed using GC/MS to measure the imidacloprid levels in xylem fluid exudates. In May 2005, a stand of hemlock trees in West...

  9. HPLC/EC (High Pressure Liquid Chromatography/Electrochemical Detection) Studies of Selected Explosive Components, Nitroanilines, and Nitrophenols with Dual Electrode Electrochemical Detection.

    DTIC Science & Technology

    1985-09-01

    advantage of HPLC/EC for the separation and detection of electroactive species is well documented in the literature (1-5). It has been demonstrated that...Zorbax, Alltech Spherisorb or BAS Biophase columns. The injection valve was a Rheodyne Model 7120 fitted with a 20 pL loop and mounted vertically for

  10. Quantitative analysis of 23-hydroxybetulinic acid in mouse plasma using electrospray liquid chromatography/mass spectrometry.

    PubMed

    Yang, Min; Wang, Guang Ji; Wang, Su Jun; Li, Xiao Tian; Xu, Yu Ping; Wang, Song Pei; Xiang, Jing De; Pan, Shang Ren; Cao, Guo Xian; Ye, Wen Cai

    2005-01-01

    23-Hydroxybetulinic acid is a newly isolated derivative of betulinic acid. The agent exhibits potential anti-tumor activity and functions in this regard via apoptosis. In support of pharmacokinetic and toxicological evaluations, a new assay based on liquid chromatography/mass spectrometry (LC/MS) was developed for the quantitative analysis of 23-hydroxybetulinic acid. Sample preparation consisted of extraction of the plasma by the addition of methylene chloride followed by centrifugation. Aliquots of the supernatant were analyzed using an isocratic reversed-phase high-performance liquid chromatography (HPLC) system coupled to a negative ion electrospray mass spectrometer. Molecules of 23-hydroxybetulinic acid and the internal standard limonin were detected using selected ion monitoring at m/z 471 and 469, respectively. The limit of detection of 23-hydroxybetulinic acid was 0.05 pg (0.11 fmol) injected on-column (10 pg/mL, 5 microL injection volume), and the limit of quantitation was 10 pg (21.19 fmol, 2 ng/mL, 5 muL injection volume). 23-Hydroxybetulinic acid was stable in plasma samples at -20 degrees C for at least 3 weeks. The intra-day and inter-day coefficients of variation of the assay were 3.0 and 4.8%, respectively. The utility of the assay was demonstrated by measuring 23-hydroxybetulinicacid in mouse plasma following intragastric administration (IG) in vivo. Pharmacokinetic parameters were calculated using the 3P97 pharmacokinetic software package. A two-compartment, first-order model was selected for pharmacokinetic modeling. The result showed that after IG of 200 mg/kg 23-hydroxybetulinic acid, the plasma concentrations reached peaks at 2 h with C(max) of 3.1 microg/mL. The 200 mg/kg 23-hydroxybetulinic acid suspension IG doses were found to have long elimination half-lives of 25.6 h and low bioavailability of 2.3%. No interference was noted due to endogenous substances. These analytical methods should be of value in future studies related to the development and characterization of 23-hydroxybetulinic acid. Copyright 2005 John Wiley & Sons, Ltd.

  11. In situ laser-induced photochemical silver substrate synthesis and sequential SERS detection in a flow cell.

    PubMed

    Herman, Krisztian; Szabó, László; Leopold, Loredana F; Chiş, Vasile; Leopold, Nicolae

    2011-05-01

    A new, simple, and effective approach for multianalyte sequential surface-enhanced Raman scattering (SERS) detection in a flow cell is reported. The silver substrate was prepared in situ by laser-induced photochemical synthesis. By focusing the laser on the 320 μm inner diameter glass capillary at 0.5 ml/min continuous flow of 1 mM silver nitrate and 10 mM sodium citrate mixture, a SERS active silver spot on the inner wall of the glass capillary was prepared in a few seconds. The test analytes, dacarbazine, 4-(2-pyridylazo)resorcinol (PAR) complex with Cu(II), and amoxicillin, were sequentially injected into the flow cell. Each analyte was adsorbed to the silver surface, enabling the recording of high intensity SERS spectra even at 2 s integration times, followed by desorption from the silver surface and being washed away from the capillary. Before and after each analyte passed the detection window, citrate background spectra were recorded, and thus, no "memory effects" perturbed the SERS detection. A good reproducibility of the SERS spectra obtained under flow conditions was observed. The laser-induced photochemically synthesized silver substrate enables high Raman enhancement, is characterized by fast preparation with a high success rate, and represents a valuable alternative for silver colloids as SERS substrate in flow approaches.

  12. Hyphenation of ultra high performance supercritical fluid chromatography with atmospheric pressure chemical ionisation high resolution mass spectrometry: Part 1. Study of the coupling parameters for the analysis of natural non-polar compounds.

    PubMed

    Duval, Johanna; Colas, Cyril; Pecher, Virginie; Poujol, Marion; Tranchant, Jean-François; Lesellier, Eric

    2017-08-04

    An analytical method based on Ultra-High-Performance Supercritical Fluid Chromatography (UHPSFC) coupled with Atmospheric Pressure Chemical Ionization - High-resolution mass spectrometry (APCI-Q-TOF-HRMS) was developed for compounds screening from oily samples. The hyphenation was made using a commercial UHPLC device coupled to a CO 2 pump in order to perform the chromatographic analysis. An adaptation of the injection system for compressible fluids was accomplished for this coupling: this modification of the injection sequence was achieved to prevent unusual variations of the injected volume related to the use of a compressible fluid. UHPSFC-HRMS hyphenation was optimized to enhance the response of the varied compounds from a seed extract (anthraquinones, free fatty acids, diacylglycerols, hydroxylated triacylglycerols and triacylglycerols). No split was used prior to the APCI ionization source, allowing introducing all the compounds in the spectrometer, ensuring a better sensitivity for minor compounds. The effects of a mechanical make-up (T-piece) added before this ionization source was discussed in terms of standard deviation of response, response intensity and fragmentation percentage. The location of the T-piece with regards to the backpressure regulator (BPR), the flow rate and the nature of the make-up solvent were studied. Results show that the effects of the studied parameters depend on the nature of the compounds, whereas the make-up addition favours the robustness of the mass response (quantitative aspect). Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Isotope-dilution gas chromatography-mass spectrometry coupled with injection-port butylation for the determination of 4-t-octylphenol, 4-nonylphenols and bisphenol A in human urine.

    PubMed

    Chung, Shuang-Hung; Ding, Wang-Hsien

    2018-02-05

    An analytical method that utilizes isotope-dilution gas chromatography-mass spectrometry (ID-GC-MS) coupled with injection-port butylation was developed. The method was validated, and confirmed to be able to determine the presence of three commonly detected endocrine-disrupting chemicals (EDCs: 4-tert-octylphenol (4-t-OP), 4-nonylphenols (4-NPs) and bisphenol A (BPA)) in human urine with high precision and accuracy. After sample preparation by solid-phase extraction, the extract was introduced into GC-MS via injection-port butylation. The butylated target analytes were identified and quantified by using ion-trap mass spectrometry operating in the selected-ion-storage mode, and employing the measurement of peak area ratios of the butylated target analytes and labeled-analogues in the samples and calibration standards. The labeled-analogues were also used to correct the variations associated with the analysis and matrix effect. The limits of quantitation (LOQs) ranged from 0.1 to 0.3ng/mL. High precisions for both intra- and inter-day analysis ranged from 1 to 6%, and excellent accuracy (mean recovery) ranged from 92 to 105% on two concentration levels. In human urine, the total concentrations of three selected EDCs varied from 1.28 to 7.14ng/mL. 4-NPs were detected within all collected samples. The developed method allows accurate analysis of trace-level of EDCs in urine, and these target EDCs could act as useful biomarkers to assess exposure in biomonitoring studies and programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Kinetic Titration Series with Biolayer Interferometry

    PubMed Central

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647

  15. Kinetic titration series with biolayer interferometry.

    PubMed

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1-42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations.

  16. Selection of adsorption traps for in situ gas chromatographic analysis of polar regolith volatiles on board of the Luna-Resource lander

    NASA Astrophysics Data System (ADS)

    Aseev, Sergey; Gerasimov, Mikhail; Zaitsev, Maxim

    Investigation of volatile species in the polar regions of the Moon is an important task for better understanding of its evolution and for further exploration, in particular, to provide resources for future permanent stations. Gas chromatographic complex of Space Research Institute of the Russian Academy of Science is focused on measurements of volatile compounds composition, supposedly existing in the polar regions of the Moon in the area of Luna-Resource probe landing (2017). Also, this devise can be used on the Mars in the area of ExoMars landing mission (2018). One of the features of this gas analytical system is the use of adsorption traps, which can retain volatile compounds continuously coming into the gas chromatograph as a result of pyrolysis of the regolith sample and shortly release them for injection into chromatographic system for analysis. To improve sensitivity and analytical properties of the gas chromatograph, it’s necessary to provide concentrated injection of all the volatile components, which were released during pyrolysis of the regolith sample. It takes ~15 minutes to complete this pyrolysis operation. Such permanent gases as noble gases and N2, Ar, CO on the left hand have low dynamic viscosity, which cause their short retention time in adsorption traps, but on the right hand - these gases are released from the soil sample close to the end of the heating cycle. Summarizing these principles, we can say that 5 minutes of trapping for specified gases is efficient enough for their accumulation with consequent heating of adsorption trap up to 150°C to produce concentrated injection of all these compounds to the analytical columns of gas chromatography system. In the most of space missions (Viking, Phoenix, MSL, Rosetta), which use gas chromatography as the main method for in situ chemical analysis of volatiles, chromatography columns are usually mounted in parallel scheme. It is well known that water has a negative influence on analytical characteristics of several chromatography columns types. This can take place because water can fill absorption pours, and this can result in column’s retention time and capacity variation. The use of adsorption traps can preserve chromatography columns from negative influence of some compounds and improve threshold of detection by several orders of magnitude in the analysis of volatiles composition of planetary soils, as well as in direct atmospheric measurements. The paper is dedicated to the investigation of typical retention time for noble and permanent gases, such as CO2, CO, CH4, N2, Ar on the adsorbents Carbosieve, PoraPak Q and Molsieve 5A , depending on their cooling temperature. Based on results of the measurements we developed and tested new experimental techniques suitable for analysis of different adsorbents types, which can be used as a new basis for future adsorption traps. Acknowledgements: This work was supported in part by P-22 Program of the RAS.

  17. Targeted Drug Delivery in the Suprachoroidal Space by Swollen Hydrogel Pushing.

    PubMed

    Jung, Jae Hwan; Desit, Patcharin; Prausnitz, Mark R

    2018-04-01

    The purpose is to target model drug particles to the posterior region of the suprachoroidal space (SCS) of the eye controlled via pushing by hydrogel swelling. A particle formulation containing 1% hyaluronic acid (HA) with fluorescent polymer particles and a hydrogel formulation containing 4% HA were introduced in a single syringe as two layers without mixing, and injected sequentially into the SCS of the rabbit eye ex vivo and in vivo using a microneedle. Distribution of particles in the eye was determined by microscopy. During injection, the particle formulation was pushed toward the middle of the SCS by the viscous hydrogel formulation, but less than 12% of particles reached the posterior SCS. After injection, the particle formulation was pushed further toward the macula and optic nerve in the posterior SCS by hydrogel swelling and spreading. Heating the eye to 37°C, or injecting in vivo decreased viscosity and mechanical strength of the hydrogel, thereby allowing it to swell and flow further in the SCS. A high salt concentration (9% NaCl) in the hydrogel formulation further increased hydrogel swelling due to osmotic flow into the hydrogel. In this way, up to 76% of particles were delivered to the posterior SCS from an injection made near the limbus. This study shows that model drug particles can be targeted to the posterior SCS by HA hydrogel swelling and pushing without particle functionalization or administering external driving forces.

  18. Histopathological Alterations after Single Epidural Injection of Ropivacaine, Methylprednizolone Acetate, or Contrast Material in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kitsou, Maria-Chrysanthi; Kostopanagiotou, Georgia; Kalimeris, Konstantinos

    Purpose: The consequences from the injection of different types of drugs in the epidural space remains unknown. Increasing evidence suggests that localized inflammation, fibrosis, and arachnoiditis can complicate sequential epidural blockades, or even epidural contrast injection. We investigate the in vivo effect of epidural injections in the epidural space in an animal model. Materials and Methods: A group of ten male adult pigs, five punctures to each at distinct vertebral interspaces under general anesthesia, were examined, testing different drugs, used regularly in the epidural space (iopamidol, methylprednisolone acetate, ropivacaine). Each site was marked with a percutaneous hook wire marker. Histologicalmore » analysis of the epidural space, the meninges, and the underlying spinal cord of the punctured sites along with staining for caspase-3 followed 20 days later. Results: The epidural space did not manifest adhesions or any other pathology, and the outer surface of the dura was not impaired in any specimen. The group that had the contrast media injection showed a higher inflammation response compared to the other groups (P = 0.001). Positive staining for caspase-3 was limited to <5% of neurons with all substances used. Conclusion: No proof of arachnoiditis and/or fibrosis was noted in the epidural space with the use of the above-described drugs. A higher inflammation rate was noted with the use of contrast media.« less

  19. Measurement of density and affinity for dopamine D2 receptors by a single positron emission tomography scan with multiple injections of [11C]raclopride

    PubMed Central

    Ikoma, Yoko; Watabe, Hiroshi; Hayashi, Takuya; Miyake, Yoshinori; Teramoto, Noboru; Minato, Kotaro; Iida, Hidehiro

    2010-01-01

    Positron emission tomography (PET) with [11C]raclopride has been used to investigate the density (Bmax) and affinity (Kd) of dopamine D2 receptors related to several neurological and psychiatric disorders. However, in assessing the Bmax and Kd, multiple PET scans are necessary under variable specific activities of administered [11C]raclopride, resulting in a long study period and unexpected physiological variations. In this paper, we have developed a method of multiple-injection graphical analysis (MI-GA) that provides the Bmax and Kd values from a single PET scan with three sequential injections of [11C]raclopride, and we validated the proposed method by performing numerous simulations and PET studies on monkeys. In the simulations, the three-injection protocol was designed according to prior knowledge of the receptor kinetics, and the errors of Bmax and Kd estimated by MI-GA were analyzed. Simulations showed that our method could support the calculation of Bmax and Kd, despite a slight overestimation compared with the true magnitudes. In monkey studies, we could calculate the Bmax and Kd of diseased or normal striatum in a 150 mins scan with the three-injection protocol of [11C]raclopride. Estimated Bmax and Kd values of D2 receptors in normal or partially dopamine-depleted striatum were comparable to the previously reported values. PMID:19904285

  20. Microbially Enhanced Oil Recovery by Sequential Injection of Light Hydrocarbon and Nitrate in Low- And High-Pressure Bioreactors.

    PubMed

    Gassara, Fatma; Suri, Navreet; Stanislav, Paul; Voordouw, Gerrit

    2015-10-20

    Microbially enhanced oil recovery (MEOR) often involves injection of aqueous molasses and nitrate to stimulate resident or introduced bacteria. Use of light oil components like toluene, as electron donor for nitrate-reducing bacteria (NRB), offers advantages but at 1-2 mM toluene is limiting in many heavy oils. Because addition of toluene to the oil increased reduction of nitrate by NRB, we propose an MEOR technology, in which water amended with light hydrocarbon below the solubility limit (5.6 mM for toluene) is injected to improve the nitrate reduction capacity of the oil along the water flow path, followed by injection of nitrate, other nutrients (e.g., phosphate) and a consortium of NRB, if necessary. Hydrocarbon- and nitrate-mediated MEOR was tested in low- and high-pressure, water-wet sandpack bioreactors with 0.5 pore volumes of residual oil in place (ROIP). Compared to control bioreactors, those with 11-12 mM of toluene in the oil (gained by direct addition or by aqueous injection) and 80 mM of nitrate in the aqueous phase produced 16.5 ± 4.4% of additional ROIP (N = 10). Because toluene is a cheap commodity chemical, HN-MEOR has the potential to be a cost-effective method for additional oil production even in the current low oil price environment.

  1. A novel sample preparation procedure for effect-directed analysis of micro-contaminants of emerging concern in surface waters.

    PubMed

    Osorio, Victoria; Schriks, Merijn; Vughs, Dennis; de Voogt, Pim; Kolkman, Annemieke

    2018-08-15

    A novel sample preparation procedure relying on Solid Phase Extraction (SPE) combining different sorbent materials on a sequential-based cartridge was optimized and validated for the enrichment of 117 widely diverse contaminants of emerging concern (CECs) from surface waters (SW) and further combined chemical and biological analysis on subsequent extracts. A liquid chromatography coupled to high resolution tandem mass spectrometry LC-(HR)MS/MS protocol was optimized and validated for the quantitative analysis of organic CECs in SW extracts. A battery of in vitro CALUX bioassays for the assessment of endocrine, metabolic and genotoxic interference and oxidative stress were performed on the same SW extracts. Satisfactory recoveries ([70-130]%) and precision (< 30%) were obtained for the majority of compounds tested. Internal standard calibration curves used for quantification of CECs, achieved the linearity criteria (r 2 > 0.99) over three orders of magnitude. Instrumental limits of detection and method limits of quantification were of [1-96] pg injected and [0.1-58] ng/L, respectively; while corresponding intra-day and inter-day precision did not exceed 11% and 20%. The developed procedure was successfully applied for the combined chemical and toxicological assessment of SW intended for drinking water supply. Levels of compounds varied from < 10 ng/L to < 500 ng/L. Endocrine (i.e. estrogenic and anti-androgenic) and metabolic interference responses were observed. Given the demonstrated reliability of the validated sample preparation method, the authors propose its integration in an effect-directed analysis procedure for a proper evaluation of SW quality and hazard assessment of CECs. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. PCSK9 inhibition with alirocumab reduces lipoprotein(a) levels in nonhuman primates by lowering apolipoprotein(a) production rate.

    PubMed

    Croyal, Mikaël; Tran, Thi-Thu-Trang; Blanchard, Rose Hélène; Le Bail, Jean-Christophe; Villard, Elise F; Poirier, Bruno; Aguesse, Audrey; Billon-Crossouard, Stéphanie; Ramin-Mangata, Stéphane; Blanchard, Valentin; Nativel, Brice; Chemello, Kévin; Khantalin, Ilya; Thedrez, Aurélie; Janiak, Philip; Krempf, Michel; Boixel, Christophe; Lambert, Gilles; Guillot, Etienne

    2018-05-31

    Therapeutic antibodies targeting proprotein convertase subtilisin kexin type 9 (PCSK9) (e.g. alirocumab) lower low-density lipoprotein cholesterol (LDL-C) and lipoprotein (a) [Lp(a)] levels in clinical trials. We recently showed that PCSK9 enhances apolipoprotein(a) [apo(a)] secretion from primary human hepatocytes but does not affect Lp(a) cellular uptake. Here, we aimed to determine how PCSK9 neutralization modulates Lp(a) levels in vivo Six nonhuman primates (NHP) were treated with alirocumab or a control antibody (IgG1) in a crossover protocol. After the lowering of lipids reached steady state, NHP received an intravenous injection of [ 2 H 3 ]-leucine, and blood samples were collected sequentially over 48 h. Enrichment of apolipoproteins in [ 2 H 3 ]-leucine was assessed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Kinetic parameters were calculated using numerical models with the SAAMII software. Compared with IgG1, alirocumab significantly reduced total cholesterol (TC) (-28%), LDL-C (-67%), Lp(a) (-56%), apolipoprotein B100 (apoB100) (-53%), and apo(a) (-53%). Alirocumab significantly increased the fractional catabolic rate of apoB100 (+29%) but not that of apo(a). Conversely, alirocumab sharply and significantly reduced the production rate (PR) of apo(a) (-42%), but not significantly that of apoB100, compared with IgG1, respectively.In line with the observations made in human hepatocytes, the present kinetic study establishes that PCSK9 neutralization with alirocumab efficiently reduces circulating apoB100 and apo(a) levels by distinct mechanisms: apoB primarily by enhancing its catabolism and apo(a) primarily by lowering its production. © 2018 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohn, J.S.; Wagner, D.A.; Cohn, S.D.

    Six normolipidemic male subjects, after an 8-h overnight fast, were given a bolus injection and then a 15-h constant intravenous infusion of (D3)L-leucine. Subjects were studied in the fasted state and on a second occasion in the fed state (small, physiological meals were given every hour for 15 h). Apolipoproteins were isolated by preparative gradient gel electrophoresis from plasma lipoproteins separated by sequential ultracentrifugation. Incorporation of (D3)L-leucine into apolipoproteins was monitored by negative ionization, gas chromatography-mass spectrometry. Production rates were determined by multiplying plasma apolipoprotein pool sizes by fractional production rates calculated as the rate of isotopic enrichment (IE) ofmore » each protein as a fraction of IE achieved by VLDL (d less than 1.006 g/ml) apo B-100 at plateau. VLDL apo B-100 production was greater, and LDL (1.019 less than d less than 1.063 g/ml) apo B-100 production was less in the fed compared with the fasted state (9.9 +/- 1.7 vs. 6.4 +/- 1.7 mg/kg per d, P less than 0.01, and 8.9 +/- 1.2 vs. 13.1 +/- 1.2 mg/kg per d, P less than 0.05, respectively). No mean change was observed in high density lipoprotein apo A-I production. We conclude that: (a) this stable isotope, endogenous-labeling technique, for the first time allows for the in vivo measurement of apolipoprotein production in the fasted and fed state; and (b) since LDL apo B-100 production was greater than VLDL apo B-100 production in the fasted state, this study provides in vivo evidence that LDL apo B-100 can be produced independently of VLDL apo B-100 in normolipidemic subjects.« less

  4. Structural and spectrophotometric characterization of 2-[4-(dimethylamino)styryl]-1-ethylquinolinium iodide as a reagent for sequential injection determination of tungsten

    NASA Astrophysics Data System (ADS)

    Bazel, Yaroslav; Lešková, Martina; Rečlo, Michal; Šandrejová, Jana; Simon, András; Fizer, Maksym; Sidey, Vasyl

    2018-05-01

    Structure, spectrophotometric and protolytic properties of the styryl dye 2-[4-(dimethylamino)styryl]-1-ethylquinolinium iodide (R) as well as its complex with tungsten were studied. The selective protonation of dimethylamino group was confirmed by density functional theory investigation through the computation of Fukui function, NPA partial atomic charges, and NICS(0) aromaticity indexes. The TD-DFT study explains the experimental change of color by excluding the dimethylamino group from HOMO orbital upon protonation. The acid dissociation constant, the optimum wavelength and the molar absorptivity of R were found to be: 3.02, 501 nm and 4.0 × 104 L mol-1 cm-1, respectively. The protolytic properties of the reagent were found to change significantly in the presence of tungsten(VI). Analysis of bond critical points between the anions and Quinaldine Red cation gives the selectivity raw HWO4- > MoO4-> H2VO4- > ReO4- > ClO4-, that perfectly match with the experimental data. Based on this observation, a non-extractive sequential-injection spectrophotometric method for the determination of tungsten was developed. The absorbance of the colored extracts obeys Beer's law up to 55.2 mg L-1 of W at 520 nm wavelength. The limit of detection calculated from a blank test (n = 10) based on 3 s was 0.96 mg L-1. The developed method was applied for the determination of tungsten in model samples.

  5. Sequential changes in the expression of Wnt- and Notch-related genes in the vagina and uterus of ovariectomized mice after estrogen exposure.

    PubMed

    Nakamura, Takeshi; Miyagawa, Shinichi; Katsu, Yoshinao; Sato, Tomomi; Iguchi, Taisen; Ohta, Yasuhiko

    2012-01-01

    Estrogen regulates morphological changes in reproductive organs, such as the vagina and uterus, during the estrous cycles in mice. Estrogen depletion by ovariectomy in adults results in atrophy accompanied by apoptosis in vaginal and uterine cells, while estrogen treatment following ovariectomy elicits cell proliferation in both organs. Sequential changes in mRNA expression of wingless-related MMTV integration site (Wnt) and Notch signaling genes were analyzed in the vagina and uterus of ovariectomized adult mice after a single injection of 17β-estradiol to provide understanding over the molecular basis of differences in response to estrogen in these organs. We found estrogen-dependent up-regulation of Wnt4, Wnt5a and p21 and down-regulation of Wnt11, hairy/enhancer-of-split related with YRPW motif-1 (Hey1) and delta-like 4 (Dll4) in the vagina, and up-regulation of Wnt4, Wnt5a, Hey1, Heyl, Dll1, p21 and p53 and down-regulation of Wnt11, Hey2 and Dll4 in the uterus. The expression of Wnt4, Hey1, Hey2, Heyl, Dll1 and p53 showed different patterns after the estrogen injection. Expression patterns for Wnt5a, Wnt11, Dll4 and p21 in the vagina and uterus were similar, suggesting that these genes are involved in the proliferation of cells in both those organs in mice.

  6. Automated solid-phase extraction hyphenated to voltammetry for the determination of quercetin using magnetic nanoparticles and sequential injection lab-on-valve approach.

    PubMed

    Wang, Yang; Wang, Lu; Tian, Tian; Hu, Xiaoya; Yang, Chun; Xu, Qin

    2012-05-21

    In this study, an automated sequential injection lab-on-valve (SI-LOV) system was designed for the on-line matrix removal and preconcentration of quercetin. Octadecyl functionalized magnetic silica nanoparticles were prepared and packed into the microcolumn of the LOV as adsorbents. After being adsorbed through hydrophobic interaction, the analyte was eluted and subsequently introduced into the electrochemical flow cell by voltammetric quantification. The main parameters affecting the performance of solid-phase extraction, such as sample pH and flow rate, eluent solution and volume, accumulation potential and accumulation time were investigated in detail. Under the optimum experimental conditions, a linear calibration curve was obtained in the range of 1.0 × 10(-8) to 1 × 10(-5) mol L(-1) with R(2) = 0.9979. The limit of detection (LOD) and limit of quantitation (LOQ) were 1.3 × 10(-9) and 4.3 × 10(-9) mol L(-1), respectively. The relative standard deviation (RSD) for the determination of 1.0 × 10(-6) mol L(-1) quercetin was found to be 2.9% (n = 11) along with a sampling frequency of 40 h(-1). The applicability and reliability of the automated method described here had been applied to the determination of quercetin in human urine and red wine samples through recovery experiments, and the obtained results were in good agreement with those obtained by the HPLC method.

  7. Compatibility of azathioprine sodium with intravenous fluids.

    PubMed

    Johnson, C A; Porter, W A

    1981-06-01

    The effects of storage containers, diluent, temperature, and illumination on the stability and compatibility of azathioprine sodium were studied. Reconstituted solutions were stored in the manufacturer's vial and a plastic syringe. Diluted solutions were stored in mini-bags mixed with standard intravenous solutions (5% dextrose injection, 0.9% sodium chloride injection, and 0.45% sodium chloride injection). Samples were stored at 4 degrees C in the dark and at 23 degrees C under constant illumination. Samples containing an internal standard, 6-methylmercaptopurine, were assayed by ion exchange chromatography at 0, 8, and 16 days. Accelerated decomposition studies at 70 degrees C also were performed to determine the chromatographic method's capability for separating azathioprine from its breakdown products. No solutions or admixtures differed significantly (p greater than 0.13) from initial concentrations after 16 days at 23 degrees C under constant illumination. Mixture with 5% dextrose injection caused precipitation by day 16. Azathioprine sodium reconstituted and stored in the manufacturer's vial or a plastic syringe at 4 degrees C formed a precipitate by day 4. Sterility is the limiting factor determining suitability for use of azathioprine solutions kept less than four days.

  8. [Application of fingerprint chromatogram in quality control of Shen-Mai injection].

    PubMed

    Shi, Xian-zhe; Yang, Jun; Zhao, Chun-xia; Xiong, Jian-hui; Xu, Guo-wang

    2002-07-01

    The theory and practice of traditional Chinese medicine require some comprehensive methods to assess quality of the Chinese herbal medication. Fingerprint chromatogram is one of the feasible approaches to evaluate the quality of Chinese herbal medication. So the fingerprint chromatogram of Shen-Mai injection was established by using reversed-phase high performance liquid chromatography. The chromatographic conditions were as follows: a Hypersil C18 column was used; the mobile phase was composed of water (A) and acetontrile (B) with linear gradient elution (0-50 min, 5%-95% B, volume fraction); the flow rate was 1.0 mL/min and the UV absorbance detection was set at 202 nm. The peak-area ratios of twenty-three fingerprint peaks and internal standard (diphenyl) were taken as the criteria for quality control. The quality differences in various batches and various manufacturers of Shen-Mai injections were investigated by projection discriminance based on principal component analysis. The results show the method developed is convenient, reliable and applicable for the quality control analysis of Shen-Mai injection.

  9. Stability of methadone hydrochloride in 0.9% sodium chloride injection in single-dose plastic containers.

    PubMed

    Denson, D D; Crews, J C; Grummich, K W; Stirm, E J; Sue, C A

    1991-03-01

    The stability of methadone hydrochloride in 0.9% sodium chloride injection in flexible polyvinyl chloride containers was studied. Commercially available methadone hydrochloride 20 mg/mL and 25-mL single-dose bags of 0.9% sodium chloride injection were used. Six samples each were prepared at methadone hydrochloride concentrations of 1, 2, and 5 mg/mL. The solutions were stored at room temperature and were not protected from light. Immediately after preparation and after two, three, and four weeks of storage, each of the 18 samples was divided into three aliquots, each of which was analyzed in duplicate for methadone hydrochloride concentration by gas chromatography. There was less than 10% change in methadone hydrochloride concentration in any sample throughout the four-week study period. Methadone hydrochloride at concentrations of 1, 2, and 5 mg/mL prepared in commercially available flexible polyvinyl chloride containers of 0.9% sodium chloride injection and stored at room temperature without deliberate protection from light is stable for at least four weeks.

  10. Preparation and biocompatibility study of in situ forming polymer implants in rat brains.

    PubMed

    Nasongkla, Norased; Boongird, Atthaporn; Hongeng, Suradej; Manaspon, Chawan; Larbcharoensub, Noppadol

    2012-02-01

    We describe the development of polymer implants that were designed to solidify once injected into rat brains. These implants comprised of glycofurol and copolymers of D: ,L: -lactide (LA), ε-caprolactone and poly(ethylene glycol) (PLECs). Scanning electron microscopy (SEM) and gel permeation chromatography (GPC) showed that the extent of implant degradation was increased with LA: content in copolymers. SEM analysis revealed the formation of porosity on implant surface as the degradation proceeds. PLEC with 19.3% mole of LA: was chosen to inject in rat brains at the volume of 10, 25 and 40 μl. Body weights, hematological and histopathological data of rats treated with implants were evaluated on day 3, 6, 14, 30 and 45 after the injection. Polymer solution at the injection volume of 10 μl were tolerated relatively well compared to those of 25 and 40 μl as confirmed by higher body weight and healing action (fibrosis tissue) 30 days after treatment. The results from this study suggest a possible application as drug delivery systems that can bypass the blood brain barrier.

  11. Determination of suspected allergens in cosmetic products by headspace-programmed temperature vaporization-fast gas chromatography-quadrupole mass spectrometry.

    PubMed

    del Nogal Sánchez, Miguel; Pérez-Pavón, José Luis; Moreno Cordero, Bernardo

    2010-07-01

    In the present work, a strategy for the qualitative and quantitative analysis of 24 volatile compounds listed as suspected allergens in cosmetics by the European Union is reported. The list includes benzyl alcohol, limonene, linalool, methyl 2-octynoate, beta-citronellol, geraniol, citral (two isomers), 7-hydroxycitronellal, anisyl alcohol, cinnamal, cinnamyl alcohol, eugenol, isoeugenol (two isomers), coumarin, alpha-isomethyl ionone, lilial, alpha-amylcinnamal, lyral, alpha-amylcinnamyl alcohol, farnesol (three isomers), alpha-hexyl cinnamal, benzyl cinnamate, benzyl benzoate, and benzyl salicylate. The applicability of a headspace (HS) autosampler in combination with a gas chromatograph (GC) equipped with a programmable temperature vaporizer (PTV) and a quadrupole mass spectrometry (qMS) detector is explored. By using a headspace sampler, sample preparation is reduced to introducing the sample into the vial. This reduces the analysis time and the experimental errors associated with this step of the analytical process. Two different injection techniques were used: solvent-vent injection and hot-split injection. The first offers a way to improve sensitivity at the same time maintaining the simple headspace instrumentation and it is recommended for compounds at trace levels. The use of a liner packed with Tenax-TA allowed the compounds of interest to be retained during the venting process. The signals obtained when hot-split injection was used allowed quantification of all the compounds according to the thresholds of the European Cosmetics Directive. Monodimensional gas chromatography coupled to a conventional quadrupole mass spectrometry detector was used and the 24 analytes were separated appropriately along a run time of about 12 min. Use of the standard addition procedure as a quantification technique overcame the matrix effect. It should be emphasized that the method showed good precision and accuracy. Furthermore, it is rapid, simple, and--in view of the results--highly suitable for the determination of suspected allergens in different cosmetic products.

  12. Digital Image Speckle Correlation for the Quantification of the Cosmetic Treatment with Botulinum Toxin Type A (BTX-A)

    NASA Astrophysics Data System (ADS)

    Bhatnagar, Divya; Conkling, Nicole; Rafailovich, Miriam; Dagum, Alexander

    2012-02-01

    The skin on the face is directly attached to the underlying muscles. Here, we successfully introduce a non-invasive, non-contact technique, Digital Image Speckle Correlation (DISC), to measure the precise magnitude and duration of facial muscle paralysis inflicted by BTX-A. Subjective evaluation by clinicians and patients fail to objectively quantify the direct effect and duration of BTX-A on the facial musculature. By using DISC, we can (a) Directly measure deformation field of the facial skin and determine the locus of facial muscular tension(b)Quantify and monitor muscular paralysis and subsequent re-innervation following injection; (c) Continuously correlate the appearance of wrinkles and muscular tension. Two sequential photographs of slight facial motion (frowning, raising eyebrows) are taken. DISC processes the images to produce a vector map of muscular displacement from which spatially resolved information is obtained regarding facial tension. DISC can track the ability of different muscle groups to contract and can be used to predict the site of injection, quantify muscle paralysis and the rate of recovery following BOTOX injection.

  13. Redesigning flow injection after 40 years of development: Flow programming.

    PubMed

    Ruzicka, Jaromir Jarda

    2018-01-01

    Automation of reagent based assays, by means of Flow Injection (FI), is based on sample processing, in which a sample flows continuously towards and through a detector for quantification of the target analyte. The Achilles heel of this methodology, the legacy of Auto Analyzer®, is continuous reagent consumption, and continuous generation of chemical waste. However, flow programming, assisted by recent advances in precise pumping, combined with the lab-on-valve technique, allows the FI manifold to be designed around a single confluence point through which sample and reagents are sequentially directed by means of a series of flow reversals. This approach results in sample/reagent mixing analogous to the traditional FI, reduces sample and reagent consumption, and uses the stop flow technique for enhancement of the yield of chemical reactions. The feasibility of programmable Flow Injection (pFI) is documented by example of commonly used spectrophotometric assays of, phosphate, nitrate, nitrite and glucose. Experimental details and additional information are available in online tutorial http://www.flowinjectiontutorial.com/. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Concentration determination of urinary metabolites of N,N-dimethylacetamide by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Yamamoto, Shinobu; Matsumoto, Akiko; Yui, Yuko; Miyazaki, Shota; Kumagai, Shinji; Hori, Hajime; Ichiba, Masayoshi

    2018-03-27

    N,N-Dimethylacetamide (DMAC) is widely used in industry as a solvent. It can be absorbed through human skin. Therefore, it is necessary to determine exposure to DMAC via biological monitoring. However, the precision of traditional gas chromatography (GC) is low due to the thermal decomposition of metabolites in the high-temperature GC injection port. To overcome this problem, we have developed a new method for the simultaneous separation and quantification of urinary DMAC metabolites using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Urine samples were diluted 10-fold in formic acid, and 1-μl aliquots were injected into the LC-MS/MS equipment. A C18 reverse-phase Octa Decyl Silyl (ODS) column was used as the analytical column, and the mobile phase consisted of a mixture of methanol and aqueous formic acid solution. Urinary concentrations of DMAC and its known metabolites (N-hydroxymethyl-N-methylacetamide (DMAC-OH), N-methylacetamide (NMAC), and S- (acetamidomethyl) mercapturic acid (AMMA) ) were determined in a single run. The dynamic ranges of the calibration curves were 0.05-5 mg/l (r≥0.999) for all four compounds. The limits of detection for DMAC, DMAC-OH, NMAC, and AMMA in urine were 0.04, 0.02, 0.05, and 0.02 mg/l, respectively. Within-run accuracies were 96.5%-109.6% with relative standard deviations of precision being 3.43%-10.31%. The results demonstrated that the proposed method could successfully quantify low concentrations of DMAC and its metabolites with high precision. Hence, this method is useful for evaluating DMAC exposure. In addition, this method can be used to examine metabolite behaviors in human bodies after exposure and to select appropriate biomarkers.

  15. Concentration determination of urinary metabolites of N,N-dimethylacetamide by high-performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Yamamoto, Shinobu; Matsumoto, Akiko; Yui, Yuko; Miyazaki, Shota; Kumagai, Shinji; Hori, Hajime; Ichiba, Masayoshi

    2017-01-01

    Objectives: N,N-Dimethylacetamide (DMAC) is widely used in industry as a solvent. It can be absorbed through human skin. Therefore, it is necessary to determine exposure to DMAC via biological monitoring. However, the precision of traditional gas chromatography (GC) is low due to the thermal decomposition of metabolites in the high-temperature GC injection port. To overcome this problem, we have developed a new method for the simultaneous separation and quantification of urinary DMAC metabolites using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methods: Urine samples were diluted 10-fold in formic acid, and 1-μl aliquots were injected into the LC-MS/MS equipment. A C18 reverse-phase Octa Decyl Silyl (ODS) column was used as the analytical column, and the mobile phase consisted of a mixture of methanol and aqueous formic acid solution. Results: Urinary concentrations of DMAC and its known metabolites (N-hydroxymethyl-N-methylacetamide (DMAC-OH), N-methylacetamide (NMAC), and S- (acetamidomethyl) mercapturic acid (AMMA) ) were determined in a single run. The dynamic ranges of the calibration curves were 0.05-5 mg/l (r≥0.999) for all four compounds. The limits of detection for DMAC, DMAC-OH, NMAC, and AMMA in urine were 0.04, 0.02, 0.05, and 0.02 mg/l, respectively. Within-run accuracies were 96.5%-109.6% with relative standard deviations of precision being 3.43%-10.31%. Conclusions: The results demonstrated that the proposed method could successfully quantify low concentrations of DMAC and its metabolites with high precision. Hence, this method is useful for evaluating DMAC exposure. In addition, this method can be used to examine metabolite behaviors in human bodies after exposure and to select appropriate biomarkers. PMID:29213009

  16. Problems and solutions of polyethylene glycol co-injection method in multiresidue pesticide analysis by gas chromatography-mass spectrometry: evaluation of instability phenomenon in type II pyrethroids and its suppression by novel analyte protectants.

    PubMed

    Akutsu, Kazuhiko; Kitagawa, Yoko; Yoshimitsu, Masato; Takatori, Satoshi; Fukui, Naoki; Osakada, Masakazu; Uchida, Kotaro; Azuma, Emiko; Kajimura, Keiji

    2018-05-01

    Polyethylene glycol 300 is commonly used as a base material for "analyte protection" in multiresidue pesticide analysis via gas chromatography-mass spectrometry. However, the disadvantage of the co-injection method using polyethylene glycol 300 is that it causes peak instability in α-cyano pyrethroids (type II pyrethroids) such as fluvalinate. In this study, we confirmed the instability phenomenon in type II pyrethroids and developed novel analyte protectants for acetone/n-hexane mixture solution to suppress the phenomenon. Our findings revealed that among the examined additive compounds, three lipophilic ascorbic acid derivatives, 3-O-ethyl-L-ascorbic acid, 6-O-palmitoyl-L-ascorbic acid, and 6-O-stearoyl-L-ascorbic acid, could effectively stabilize the type II pyrethroids in the presence of polyethylene glycol 300. A mixture of the three ascorbic acid derivatives and polyethylene glycol 300 proved to be an effective analyte protectant for multiresidue pesticide analysis. Further, we designed and evaluated a new combination of analyte protectant compounds without using polyethylene glycol or the troublesome hydrophilic compounds. Consequently, we obtained a set of 10 medium- and long-chain saturated fatty acids as an effective analyte protectant suitable for acetone/n-hexane solution that did not cause peak instability in type II pyrethroids. These analyte protectants will be useful in multiresidue pesticide analysis by gas chromatography-mass spectrometry in terms of ruggedness and reliable quantitativeness. Graphical abstract Comparison of effectiveness of the addition of lipophilic derivatives of ascorbic acid in controlling the instability phenomenon of fluvalinate with polyethylene glycol 300.

  17. Molecularly imprinted-solid phase extraction combined with simultaneous derivatization and dispersive liquid-liquid microextraction for selective extraction and preconcentration of methamphetamine and ecstasy from urine samples followed by gas chromatography.

    PubMed

    Djozan, Djavanshir; Farajzadeh, Mir Ali; Sorouraddin, Saeed Mohammad; Baheri, Tahmineh

    2012-07-27

    In this study, a developed technique was reported for extraction and pre-concentration of methamphetamine (MAMP) and 3,4-methylenedioxymethamphetamine (MDMA, ecstasy) from urine samples using molecularly imprinted-solid phase extraction (MISPE) along with simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME). Molecularly imprinted microspheres as sorbent in solid phase extraction (SPE) procedure were synthesized using precipitation polymerization with MAMP as the template. Aqueous solution of the target analytes was passed through MAMP-MIP cartridge and the adsorbed analytes were then eluted with methanol. The collected eluate was mixed with butylchloroformate which served as the derivatization reagent as well as the extraction solvent. The mixture was immediately injected into deionized water. After centrifugation, 1 μL of the settled organic phase was injected into gas chromatography-flame ionization detection (GC-FID) or gas chromatography-mass spectrometry (GC-MS). Various experimental parameters affecting the performance of both of the steps (MISPE and DLLME) were thoroughly investigated. The calibration graphs were linear in the ranges of 10-1500 ng mL(-1) (MAMP) and 50-1500 ng mL(-1) (MDMA), and the detection limits (LODs) were 2 and 18 ng mL(-1), respectively. The relative standard deviations (%RSDs) obtained for six repeated experiments (100 ng mL(-1) of each drug) were 5.1% and 6.8% for MAMP and MDMA, respectively. The relative recoveries obtained for the analytes in human urine samples, spiked with different levels of each drug, were within the range of 80-88%. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Micelle to solvent stacking of organic cations in micellar electrokinetic chromatography with sodium dodecyl sulfate.

    PubMed

    Quirino, Joselito P; Aranas, Agnes T

    2011-10-14

    The on-line sample concentration technique, micelle to solvent stacking (MSS), was studied for small organic cations (quaternary ammonium herbicides, β-blocker drugs, and tricyclic antidepressant drugs) in reversed migration micellar electrokinetic chromatography. Electrokinetic chromatography was carried out in fused silica capillaries with a background solution of sodium dodecyl sulfate (SDS) in a low pH phosphate buffer. MSS was performed using anionic SDS micelles in the sample solution for analyte transport and methanol or acetonitrile as organic solvent in the background solution for analyte effective electrophoretic mobility reversal. The solvent also allowed for the separation of the analyte test mixtures. A model for focusing and separation was developed and the mobility reversal that involved micelle collapse was experimentally verified. The effect of analyte retention factor was observed by changing the % organic solvent in the background solution or the concentration of SDS in the sample matrix. With an injection length of 31.9 cm (77% of effective capillary length) for the 7 test drugs, the LODs (S/N=3) of 5-14 ng/mL were 101-346-fold better when compared to typical injection. The linearity (R(2), range=0.025-0.8 μg/mL), intraday and interday repeatability (%RSD, n=10) were ≥0.988, <6.0% and <8.5%, respectively. In addition, analysis of spiked urine samples after 10-fold dilution with the sample matrix yielded LODs=0.02-0.10 μg/mL. These LODs are comparable to published electrophoretic methods that required off-line sample concentration. However, the practicality of the technique for more complex samples will rely on dedicated sample preparation schemes. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Highly selective micro-sequential injection lab-on-valve (muSI-LOV) method for the determination of ultra-trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometry.

    PubMed

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard; Hansen, Elo Harald

    2006-10-01

    A highly selective procedure is proposed for the determination of ultra-trace level concentrations of nickel in saline aqueous matrices exploiting a micro-sequential injection Lab-On-Valve (muSI-LOV) sample pretreatment protocol comprising bead injection separation/pre-concentration and detection by electrothermal atomic absorption spectrometry (ETAAS). Based on the dimethylglyoxime (DMG) reaction used for nickel analysis, the sample, as contained in a pH 9.0 buffer, is, after on-line merging with the chelating reagent, transported to a reaction coil attached to one of the external ports of the LOV to assure sufficient reaction time for the formation of Ni(DMG)(2) chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio of hydrophilic and lipophilic monomers. Following elution by a 50-muL methanol plug in an air-segmented modality, the nickel is finally quantified by ETAAS. Under the optimized conditions and for a sample volume of 1.8 mL, a retention efficiency of 70 % and an enrichment factor of 25 were obtained. The proposed methodology showed a high tolerance to the commonly encountered alkaline earth matrix elements in environmental waters, that is, calcium and magnesium, and was successfully applied for the determination of nickel in an NIST standard reference material (NIST 1640-Trace elements in natural water), household tap water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6 %. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05.

  20. Development of a dynamic coupled hydro-geomechanical code and its application to induced seismicity

    NASA Astrophysics Data System (ADS)

    Miah, Md Mamun

    This research describes the importance of a hydro-geomechanical coupling in the geologic sub-surface environment from fluid injection at geothermal plants, large-scale geological CO2 sequestration for climate mitigation, enhanced oil recovery, and hydraulic fracturing during wells construction in the oil and gas industries. A sequential computational code is developed to capture the multiphysics interaction behavior by linking a flow simulation code TOUGH2 and a geomechanics modeling code PyLith. Numerical formulation of each code is discussed to demonstrate their modeling capabilities. The computational framework involves sequential coupling, and solution of two sub-problems- fluid flow through fractured and porous media and reservoir geomechanics. For each time step of flow calculation, pressure field is passed to the geomechanics code to compute effective stress field and fault slips. A simplified permeability model is implemented in the code that accounts for the permeability of porous and saturated rocks subject to confining stresses. The accuracy of the TOUGH-PyLith coupled simulator is tested by simulating Terzaghi's 1D consolidation problem. The modeling capability of coupled poroelasticity is validated by benchmarking it against Mandel's problem. The code is used to simulate both quasi-static and dynamic earthquake nucleation and slip distribution on a fault from the combined effect of far field tectonic loading and fluid injection by using an appropriate fault constitutive friction model. Results from the quasi-static induced earthquake simulations show a delayed response in earthquake nucleation. This is attributed to the increased total stress in the domain and not accounting for pressure on the fault. However, this issue is resolved in the final chapter in simulating a single event earthquake dynamic rupture. Simulation results show that fluid pressure has a positive effect on slip nucleation and subsequent crack propagation. This is confirmed by running a sensitivity analysis that shows an increase in injection well distance results in delayed slip nucleation and rupture propagation on the fault.

  1. The leaf volatile constituents of Isatis tinctoria by Solid-Phase Microextraction and Gas chromatography/Mass Spectrometry.

    PubMed

    Condurso, Cettina; Verzera, Antonella; Romeo, Vincenza; Ziino, Marisa; Trozzi, Alessandra; Ragusa, Salvatore

    2006-08-01

    The leaf volatile constituents of Isatis tinctoria L. (Brassicaceae) have been studied by Solid-Phase Microextraction and Gas chromatography/Mass Spectrometry (SPME/GC-MS). Seventy components were fully characterized by mass spectra, linear retention indices, and injection of standards; the average composition (ppm) as single components and classes of substances is reported. Aliphatic hydrocarbons, acids, alcohols, aldehydes and esters, aromatic aldehydes, esters and ethers, furans, isothiocyanates and thiocyanates, sulfurated compounds, nitriles, terpenes and sesquiterpenes were identified. Leaf volatiles in Isatis tinctoria L. were characterized by a high amount of isothiocyanates which accounted for about 40 % of the total volatile fraction. Isothiocyanates are important and characteristic flavour compounds in Brassica vegetables and the cancer chemo-protective attributes are recently responsible for their growing interest.

  2. Determination of sucralose in Splenda and a sugar-free beverage using high-performance anion-exchange chromatography with pulsed amperometric detection.

    PubMed

    Hanko, Valoran P; Rohrer, Jeffrey S

    2004-07-14

    Sucralose is a chlorinated carbohydrate nonnutritive sweetener of food and beverage products. The determination of sucralose in food and beverages is important to ensure consistency in product quality. Sucralose was determined in two commercial products without sample preparation using high-performance anion-exchange (HPAE) chromatography coupled with pulsed amperometric detection (PAD). Sucralose was determined with a 10 min isocratic separation. To determine sucralose and other carbohydrates (e.g., dextrose) simultaneously, a gradient separation was developed. The linear range of electrochemical response extended over 3 orders of magnitude, from 0.01 (LOD) to 40 microM (16 microg/mL; 25 microL injection). High precision, high spike recovery, and method ruggedness were observed for both samples.

  3. Strategy for large-scale isolation of enantiomers in drug discovery.

    PubMed

    Leek, Hanna; Thunberg, Linda; Jonson, Anna C; Öhlén, Kristina; Klarqvist, Magnus

    2017-01-01

    A strategy for large-scale chiral resolution is illustrated by the isolation of pure enantiomer from a 5kg batch. Results from supercritical fluid chromatography will be presented and compared with normal phase liquid chromatography. Solubility of the compound in the supercritical mobile phase was shown to be the limiting factor. To circumvent this, extraction injection was used but shown not to be efficient for this compound. Finally, a method for chiral resolution by crystallization was developed and applied to give diastereomeric salt with an enantiomeric excess of 99% at a 91% yield. Direct access to a diverse separation tool box will be shown to be essential for solving separation problems in the most cost and time efficient way. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Separation and determination of peptide metabolite of Bacillus licheniformis in a microbial fuel cell by high-speed capillary micellar electrokinetic chromatography.

    PubMed

    Wang, Wei; Bai, Ruiguang; Cai, Xiaoyu; Lin, Ping; Ma, Lihong

    2017-11-01

    A method using high-speed capillary micellar electrokinetic chromatography and a microbial fuel cell was applied to determine the metabolite of the peptides released by Bacillus licheniformis. Two peptides, l-carnosine and l-alanyl-l-glutamine were used as the substrate to feed Bacillus licheniformis in a microbial fuel cell. The metabolism process of the bacterium was monitored by analyzing the voltage outputs of the microbial fuel cell. A home-made spontaneous injection device was applied to perform high-speed capillary micellar electrokinetic chromatography. Under the optimized conditions, tryptophan, glycine, valine, tyrosine and the two peptides could be rapidly separated within 2.5 min with micellar electrokinetic chromatography mode. Then the method was applied to analyze the solutions sampled from the microbial fuel cell. After 92 h running, valine, as the metabolite, was successfully detected with concentration 3.90 × 10 -5 M. The results demonstrated that Bacillus licheniformis could convert l-carnosine and l-alanyl-l-glutamine into valine. The method employed in this work was proved to have great potential in analysis of metabolites, such as amino acids, for microorganisms. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Microwave assisted saponification (MAS) followed by on-line liquid chromatography (LC)-gas chromatography (GC) for high-throughput and high-sensitivity determination of mineral oil in different cereal-based foodstuffs.

    PubMed

    Moret, Sabrina; Scolaro, Marianna; Barp, Laura; Purcaro, Giorgia; Conte, Lanfranco S

    2016-04-01

    A high throughput, high-sensitivity procedure, involving simultaneous microwave-assisted extraction (MAS) and unsaponifiable extraction, followed by on-line liquid chromatography (LC)-gas chromatography (GC), has been optimised for rapid and efficient extraction and analytical determination of mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH) in cereal-based products of different composition. MAS has the advantage of eliminating fat before LC-GC analysis, allowing an increase in the amount of sample extract injected, and hence in sensitivity. The proposed method gave practically quantitative recoveries and good repeatability. Among the different cereal-based products analysed (dry semolina and egg pasta, bread, biscuits, and cakes), egg pasta packed in direct contact with recycled paperboard had on average the highest total MOSH level (15.9 mg kg(-1)), followed by cakes (10.4 mg kg(-1)) and bread (7.5 mg kg(-1)). About 50% of the pasta and bread samples and 20% of the biscuits and cake samples had detectable MOAH amounts. The highest concentrations were found in an egg pasta in direct contact with recycled paperboard (3.6 mg kg(-1)) and in a milk bread (3.6 mg kg(-1)). Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Simultaneous analysis of tert-butylhydroquinone, tert-butylquinone, butylated hydroxytoluene, 2-tert-butyl-4-hydroxyanisole, 3-tert-butyl-4-hydroxyanisole, α-tocopherol, γ-tocopherol, and δ-tocopherol in edible oils by normal-phase high performance liquid chromatography.

    PubMed

    Li, Jun; Bi, Yanlan; Sun, Shangde; Peng, Dan

    2017-11-01

    A normal-phase high performance liquid chromatography method for the simultaneous determination of tert-butylhydroquinone, tert-butylquinone, butylated hydroxytoluene, 2-tert-butyl-4-hydroxyanisole, 3-tert-butyl-4-hydroxyanisole, α-tocopherol, γ-tocopherol, and δ-tocopherol in edible oils was investigated. A silica column was used to separate the analytes with the gradient elution. An ultraviolet-visible detector was set at dual wavelengths mode (280 and 310nm). The column temperature was 30°C. The analytes were directly extracted with methanol. Results showed that the normal-phase high performance liquid chromatography method performed well with wide liner ranges (0.10∼500.00μg/mL, R 2 >0.9998), low limits of detection and quantitation (below 0.40 and 1.21μg/mL, respectively), and good recoveries (81.38∼102.34% in soybean oils and 83.03∼100.79% in lard, respectively). The reduction of tert-butylquinone caused by the reverse-phase high performance liquid chromatography during the injection was avoided with the current normal-phase method. The two isomers of butylated hydroxyanisole can also be separated with good resolution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Simultaneous determination of aflatoxin B₁, B₂, G₁, and G₂ in corn powder, edible oil, peanut butter, and soy sauce by liquid chromatography with tandem mass spectrometry utilizing turbulent flow chromatography.

    PubMed

    Fan, Sufang; Li, Qiang; Zhang, Xiaoguang; Cui, Xiaobin; Zhang, Dongsheng; Zhang, Yan

    2015-05-01

    A novel fully automated method based on dual column switching using turbulent flow chromatography followed by liquid chromatography with tandem mass spectrometry was developed for the determination of aflatoxin B1 , B2 , G1 , and G2 in corn powder, edible oil, peanut butter, and soy sauce samples. After ultrasound-assisted extraction, samples were directly injected to the chromatographic system and the analytes were concentrated into the clean-up loading column. Through purge switching, the analytes were transferred to the analytical column for subsequent detection by mass spectrometry. Different types of TurboFlow(TM) columns, transfer flow rate, transfer time were optimized. The limits of detection and quantification of this method ranged between 0.2-2.0 and 0.5-4.0 μg/kg for aflatoxins in different matrixes, respectively. Recoveries of aflatoxins were in range of 83-108.1% for all samples, matrix effects were in range of 34.1-104.7%. The developed method has been successfully applied in the analysis of aflatoxin B1 , B2 , G1 , and G2 in real samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Thermal cracking of poly α-olefin aviation lubricating base oil

    NASA Astrophysics Data System (ADS)

    Fei, Yiwei; Wu, Nan; Ma, Jun; Hao, Jingtuan

    2018-02-01

    Thermal cracking of poly α-olefin (PAO) was conducted under different temperatures among 190 °C to 300 °C. The reacted mixtures were sequentially detected by gas chromatography-mass spectrometer (GC/MS). A series of small molecular normal alkanes, branched alkanes and olefins were identified. PAO perfect structure of aligned comb-likely side-chains has been seriously cracked under high temperatures. Property changes about kinematic viscosity and pour point of PAO samples reacted under high temperatures were also investigated. The appearance of small molecular compounds weakened the thermal stability, viscosity temperature performance and low temperature fluidity of PAO samples. Property of PAO samples was deteriorated due to thermal cracking under high temperatures.

  9. Nitrous Oxide Explosive Hazards

    DTIC Science & Technology

    2008-05-01

    Supercritical Fluid Extraction- Capillary Gas Chromatography (SFE-GC) With a Conventional Split/Splitless Injection Port”, Journal of Chromatographic...Aromatic Hydrocarbons from Environmental Solids Using Supercritical Fluids ”, Steven B. Hawthorne and David J. Miller, Anal. Chem. 59, pp 1705-1708, 1987...Katayama, T., J. Supercrit . Fluids , 1990, 3, 78-84. 30. “ Supercritical Fluid Extraction of Fungal Oil Using CO2, N2O, CHF3, and SF6”, Keiji Sakaki

  10. METHOD 521: DETERMINATION OF NITROSAMINES IN DRINKING WATER BY SOLID PHASE EXTRACTION AND CAPILLARY COLUMN GAS CHROMATOGRAPHY WITH LARGE VOLUME INJECTION AND CHEMICAL IONIZATION TANDEM MASS SPECTROMETRY (MS/MS)

    EPA Science Inventory

    NDMA is an emerging drinking water contaminant that is of interest to EPA and the environmental community. Its presence in drinking water is a potential health concern, because the EPA's IRIS data base lists the concentration of NDMA required to result in a one in one million li...

  11. Airborne Human Odorants: Detection, Dispersion and Characterization

    DTIC Science & Technology

    2012-03-01

    begin this research. To allow the quantification of various human odorants we first calibrated the gas chromatography -mass spectrometry system that...odorants we have chosen for study are emitted from the body in axillary sweat which is a complex mixture of water, protein, lipids and other small...will be employed to quantify odorants collected from various headspaces . Experiment 1: a.) Calibration of GC-MS system was performed by injecting

  12. Easy and Fast Method for the Determination of Biogenic Amines in Fish and Fish Products with Liquid Chromatography Coupled to Orbitrap Tandem Mass Spectrometry.

    PubMed

    Kaufmann, Anton; Maden, Kathryn

    2018-03-01

    A quantitative method for the determination of biogenic amines was developed. The method is characterized by the virtual absence of sample cleanup and does not require a derivatization reaction. Diluted extracts are centrifuged, filtrated, and directly injected into an ultra-HPLC column, which is coupled to a single-stage high-resolution mass spectrometer (Orbitrap). The chromatography is based on a reversed-phase column and an eluent containing an ion-pairing agent (heptafluorobutyric acid). The high sensitivity of the instrument permits the injection of very diluted extracts, which ensures stable retention times and the virtual absence of signal suppression effects. In addition, the quantification of histamine (a regulated compound) is further aided by the use of an isotopically labeled internal standard. The method was validated for three fish-based matrixes. Both the sample processing and the analytical measurement are very fast; hence, the methodology is ideal for high-throughput work. In addition, the method is significantly more selective than conventional methods (i.e., derivatization followed by LC with UV/fluorescence (FL) detection) for biogenic amines. A comparison showed that LC-UV/FL methods can produce false-positive findings due to coeluting matrix compounds.

  13. Ultrasound extracted flavonoids from four varieties of Portuguese red grape skins determined by reverse-phase high-performance liquid chromatography with electrochemical detection.

    PubMed

    Novak, Ivana; Janeiro, Patricia; Seruga, Marijan; Oliveira-Brett, Ana Maria

    2008-12-23

    Several flavonoids present in red grape skins from four varieties of Portuguese grapes were determined by reverse-phase high-performance liquid chromatography (RP-HPLC) with electrochemical detection (ECD). Extraction of flavonoids from red grape skins was performed by ultrasonication, and hydrochloric acid in methanol was used as extraction solvent. The developed RP-HPLC method used combined isocratic and gradient elution with amperometric detection with a glassy carbon-working electrode. Good peak resolution was obtained following direct injection of a sample of red grape extract in a pH 2.20 mobile phase. Eleven different flavonoids: cyanidin-3-O-glucoside (kuromanin), delphinidin-3-O-glucoside (myrtillin), petunidin-3-O-glucoside, peonidin-3-O-glucoside, malvidin-3-O-glucoside (oenin), (+)-catechin, rutin, fisetin, myricetin, morin and quercetin, can be separated in a single run by direct injection of sample solution. The limit of detection obtained for these compounds by ECD was 20-90 pg/L, 1000 times lower when compared with photodiode array (PDA) limit of detection of 12-55 ng/L. RP-HPLC-ECD was characterized by an excellent sensitivity and selectivity, and appropriate for the simultaneous determination of these electroactive phenolic compounds present in red grape skins.

  14. Quantification of γ-Aminobutyric Acid in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    PubMed

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively.

  15. Bulk derivatization and direct injection of human cerebrospinal fluid for trace-level quantification of endogenous estrogens using trap-and-elute liquid chromatography with tandem mass spectrometry.

    PubMed

    Fan, Hui; Papouskova, Barbora; Lemr, Karel; Wigginton, Jane G; Schug, Kevin A

    2014-08-01

    Although there are existing methods for determining estrogen in human bodily fluids including blood plasma and serum, very little information is available regarding estrogen levels in human cerebrospinal fluid (CSF), which is critical to assess in studies of neuroprotective functions and diffusion of neuroprotective estrogens across the blood-brain barrier. To address this problem, a liquid chromatography with tandem mass spectrometry method for the simultaneous quantification of four endogenous estrogens (estrone, 17α-estradiol, 17β-estradiol, and estriol) in human CSF was developed. An aliquot (300 μL) of human CSF was bulk derivatized using dansyl chloride in the sample and 10 μL was directly injected onto a restricted-access media trap column for protein removal. No off-line sample extraction or cleanup was needed. The limits of detection of estrone, 17α-estradiol, 17β-estradiol, and estriol were 17, 28, 13, and 30 pg/mL, respectively, which is in the parts-per-trillion regime. The method was then applied to human CSF collected from ischemic trauma patients. Endogenous estrogens were detected and quantified, demonstrating the effectiveness of this method. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. ELECTRICALLY ACTUATED, PRESSURE-DRIVEN LIQUID CHROMATOGRAPHY SEPARATIONS IN MICROFABRICATED DEVICES

    PubMed Central

    Fuentes, Hernan V.; Woolley, Adam T.

    2012-01-01

    Electrolysis-based micropumps integrated with microfluidic channels in micromachined glass substrates are presented. Photolithography combined with wet chemical etching and thermal bonding enabled the fabrication of multi-layer devices containing electrically actuated micropumps interfaced with sample and mobile phase reservoirs. A stationary phase was deposited on the microchannel walls by coating with 10% (w/w) chlorodimethyloctadecylsilane in toluene. Pressure-balanced injection was implemented by controlling the electrolysis time and voltage applied in the two independent micropumps. Current fluctuations in the micropumps due to the stochastic formation of bubbles on the electrode surfaces were determined to be the main cause of variation between separations. On-chip electrochemical pumping enabled the loading of pL samples with no dead volume between injection and separation. A mobile phase composed of 70% acetonitrile and 30% 50 mM acetate buffer (pH 5.45) was used for the chromatographic separation of three fluorescently labeled amino acids in <40 s with an efficiency of >3000 theoretical plates in a 2.5-cm-long channel. Our results demonstrate the potential of electrochemical micropumps integrated with microchannels to perform rapid chromatographic separations in a microfabricated platform. Importantly, these devices represent a significant step toward the development of miniaturized and fully integrated liquid chromatography systems. PMID:17960281

  17. Electrically actuated, pressure-driven liquid chromatography separations in microfabricated devices.

    PubMed

    Fuentes, Hernan V; Woolley, Adam T

    2007-11-01

    Electrolysis-based micropumps integrated with microfluidic channels in micromachined glass substrates are presented. Photolithography combined with wet chemical etching and thermal bonding enabled the fabrication of multi-layer devices containing electrically actuated micropumps interfaced with sample and mobile phase reservoirs. A stationary phase was deposited on the microchannel walls by coating with 10% (w/w) chlorodimethyloctadecylsilane in toluene. Pressure-balanced injection was implemented by controlling the electrolysis time and voltage applied in the two independent micropumps. Current fluctuations in the micropumps due to the stochastic formation of bubbles on the electrode surfaces were determined to be the main cause of variation between separations. On-chip electrochemical pumping enabled the loading of pL samples with no dead volume between injection and separation. A mobile phase composed of 70% acetonitrile and 30% 50 mM acetate buffer (pH 5.45) was used for the chromatographic separation of three fluorescently labeled amino acids in <40 s with an efficiency of >3000 theoretical plates in a 2.5 cm-long channel. Our results demonstrate the potential of electrochemical micropumps integrated with microchannels to perform rapid chromatographic separations in a microfabricated platform. Importantly, these devices represent a significant step toward the development of miniaturized and fully integrated liquid chromatography systems.

  18. True ion pick (TIPick): a denoising and peak picking algorithm to extract ion signals from liquid chromatography/mass spectrometry data.

    PubMed

    Ho, Tsung-Jung; Kuo, Ching-Hua; Wang, San-Yuan; Chen, Guan-Yuan; Tseng, Yufeng J

    2013-02-01

    Liquid Chromatography-Time of Flight Mass Spectrometry has become an important technique for toxicological screening and metabolomics. We describe TIPick a novel algorithm that accurately and sensitively detects target compounds in biological samples. TIPick comprises two main steps: background subtraction and peak picking. By subtracting a blank chromatogram, TIPick eliminates chemical signals of blank injections and reduces false positive results. TIPick detects peaks by calculating the S(CC(INI)) values of extracted ion chromatograms (EICs) without considering peak shapes, and it is able to detect tailing and fronting peaks. TIPick also uses duplicate injections to enhance the signals of the peaks and thus improve the peak detection power. Commonly seen split peaks caused by either saturation of the mass spectrometer detector or a mathematical background subtraction algorithm can be resolved by adjusting the mass error tolerance of the EICs and by comparing the EICs before and after background subtraction. The performance of TIPick was tested in a data set containing 297 standard mixtures; the recall, precision and F-score were 0.99, 0.97 and 0.98, respectively. TIPick was successfully used to construct and analyze the NTU MetaCore metabolomics chemical standards library, and it was applied for toxicological screening and metabolomics studies. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Quantification of four major metabolites of embryotoxic N-methyl- and N-ethyl-2-pyrrolidone in human urine by cooled-injection gas chromatography and isotope dilution mass spectrometry.

    PubMed

    Schindler, Birgit K; Koslitz, Stephan; Meier, Swetlana; Belov, Vladimir N; Koch, Holger M; Weiss, Tobias; Brüning, Thomas; Käfferlein, Heiko U

    2012-04-17

    N-Methyl- and N-ethyl-2-pyrollidone (NMP and NEP) are frequently used industrial solvents and were shown to be embryotoxic in animal experiments. We developed a sensitive, specific, and robust analytical method based on cooled-injection (CIS) gas chromatography and isotope dilution mass spectrometry to analyze 5-hydroxy-N-ethyl-2-pyrrolidone (5-HNEP) and 2-hydroxy-N-ethylsuccinimide (2-HESI), two newly identified presumed metabolites of NEP, and their corresponding methyl counterparts (5-HNMP, 2-HMSI) in human urine. The urine was spiked with deuterium-labeled analogues of these metabolites. The analytes were separated from urinary matrix by solid-phase extraction and silylated prior to quantification. Validation of this method was carried out by using both, spiked pooled urine samples and urine samples from 56 individuals of the general population with no known occupational exposure to NMP and NEP. Interday and intraday imprecision was better than 8% for all metabolites, while the limits of detection were between 5 and 20 μg/L depending on the analyte. The high sensitivity of the method enables us to quantify NMP and NEP metabolites at current environmental exposures by human biomonitoring.

  20. [Determination of olive oil content in olive blend oil by headspace gas chromatography-mass spectrometry].

    PubMed

    Jiang, Wanfeng; Zhang, Ning; Zhang, Fengyan; Yang, Zhao

    2017-07-08

    A method for the determination of the content of olive oil in olive blend oil by headspace gas chromatography-mass spectrometry (SH-GC/MS) was established. The amount of the sample, the heating temperature, the heating time, the amount of injection, the injection mode and the chromatographic column were optimized. The characteristic compounds of olive oil were found by chemometric method. A sample of 1.0 g was placed in a 20 mL headspace flask, and heated at 180℃ for 2700 s. Then, 1.0 mL headspace gas was taken into the instrument. An HP-88 chromatographic column was used for the separation and the analysis was performed by GC/MS. The results showed that the linear range was 0-100%(olive oil content). The linear correlation coefficient ( r 2 ) was more than 0.995, and the limits of detection were 1.26%-2.13%. The deviations of olive oil contents in the olive blend oil were from -0.65% to 1.02%, with the relative deviations from -1.3% to 6.8% and the relative standard deviations from 1.18% to 4.26% ( n =6). The method is simple, rapid, environment friendly, sensitive and accurate. It is suitable for the determination of the content of olive oil in olive blend oil.

Top