Sample records for sequential injection system

  1. Therapeutic effect for liver-metastasized tumor by sequential intravenous injection of anionic polymer and cationic lipoplex of siRNA.

    PubMed

    Hattori, Yoshiyuki; Arai, Shohei; Kikuchi, Takuto; Ozaki, Kei-Ichi; Kawano, Kumi; Yonemochi, Etsuo

    2016-04-01

    Previously, we developed a novel siRNA transfer method to the liver by sequential intravenous injection of anionic polymer and cationic liposome/siRNA complex (cationic lipoplex). In this study, we investigated whether siRNA delivered by this sequential injection could significantly suppress mRNA expression of the targeted gene in liver metastasis and inhibit tumor growth. When cationic lipoplex was intravenously injected into mice bearing liver metastasis of human breast tumor MCF-7 at 1 min after intravenous injection of chondroitin sulfate C (CS) or poly-l-glutamic acid (PGA), siRNA was accumulated in tumor-metastasized liver. In terms of a gene silencing effect, sequential injections of CS or PGA plus cationic lipoplex of luciferase siRNA could reduce luciferase activity in liver MCF-7-Luc metastasis. Regarding the side effects, sequential injections of CS plus cationic lipoplex did not exhibit hepatic damage or induction of inflammatory cytokines in serum after repeated injections, but sequential injections of PGA plus cationic lipoplex did. Finally, sequential injections of CS plus cationic lipoplex of protein kinase N3 siRNA could suppress tumor growth in the mice bearing liver metastasis. From these findings, sequential injection of CS and cationic lipoplex of siRNA might be a novel systemic method of delivering siRNA to liver metastasis.

  2. Polymeric microchip for the simultaneous determination of anions and cations by hydrodynamic injection using a dual-channel sequential injection microchip electrophoresis system.

    PubMed

    Gaudry, Adam J; Nai, Yi Heng; Guijt, Rosanne M; Breadmore, Michael C

    2014-04-01

    A dual-channel sequential injection microchip capillary electrophoresis system with pressure-driven injection is demonstrated for simultaneous separations of anions and cations from a single sample. The poly(methyl methacrylate) (PMMA) microchips feature integral in-plane contactless conductivity detection electrodes. A novel, hydrodynamic "split-injection" method utilizes background electrolyte (BGE) sheathing to gate the sample flows, while control over the injection volume is achieved by balancing hydrodynamic resistances using external hydrodynamic resistors. Injection is realized by a unique flow-through interface, allowing for automated, continuous sampling for sequential injection analysis by microchip electrophoresis. The developed system was very robust, with individual microchips used for up to 2000 analyses with lifetimes limited by irreversible blockages of the microchannels. The unique dual-channel geometry was demonstrated by the simultaneous separation of three cations and three anions in individual microchannels in under 40 s with limits of detection (LODs) ranging from 1.5 to 24 μM. From a series of 100 sequential injections the %RSDs were determined for every fifth run, resulting in %RSDs for migration times that ranged from 0.3 to 0.7 (n = 20) and 2.3 to 4.5 for peak area (n = 20). This system offers low LODs and a high degree of reproducibility and robustness while the hydrodynamic injection eliminates electrokinetic bias during injection, making it attractive for a wide range of rapid, sensitive, and quantitative online analytical applications.

  3. Microfluidic Device for Sequential Injection and Flushing of Solutions and its Application to Immunosensing

    NASA Astrophysics Data System (ADS)

    Nashida, Norihiro; Suzuki, Hiroaki

    A microfluidic system with injecting and flushing functions was developed. In the system, hydrophilic flow channels have a dry-film photoresist layer which facilitates the introduction of solutions from four injection ports. The injection and flushing of solutions are controlled by valves operated by electrowetting. The valves consist of gold working electrodes in the flow channels or a through-hole in the glass substrate. Solutions can be sequentially introduced through the injection ports into a reaction chamber and flushed through a valve in the through-hole. Necessary immunoassay steps can be conducted on the chip, and a target antibody can be detected electrochemically.

  4. Sequential intravenous injection of anionic polymer and cationic lipoplex of siRNA could effectively deliver siRNA to the liver.

    PubMed

    Hattori, Yoshiyuki; Arai, Shohei; Okamoto, Ryou; Hamada, Megumi; Kawano, Kumi; Yonemochi, Etsuo

    2014-12-10

    In this study, we developed novel siRNA transfer method to the liver by sequential intravenous injection of anionic polymer and cationic liposome/cholesterol-modified siRNA complex (cationic lipoplex). When cationic lipoplex was intravenously injected into mice, the accumulation of siRNA was mainly observed in the lungs. In contrast, when cationic lipoplex was intravenously injected at 1 min after intravenous injection of poly-L-glutamic acid (PGA) or chondroitin sulfate C (CS), siRNA was accumulated in the liver. In terms of suppression of gene expression in vivo, apolipoprotein B (ApoB) mRNA in the liver and low-density-lipoprotein (LDL) and very low-density-lipoprotein (VLDL) cholesterol level in serum were reduced at 48 h after single sequential injection of PGA or CS plus cationic lipoplex of cholesterol-modified ApoB siRNA. Furthermore, sequential injections of PGA plus cationic lipoplex of cholesterol-modified luciferase siRNA could reduce luciferase activity in tumor xenografts bearing liver metastasis of human breast tumor MCF-7-Luc. From these findings, sequential injection of anionic polymer and cationic lipoplex of siRNA might produce a systemic vector of siRNA to the liver. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Sequential injection-bead injection-lab-on-valve coupled to high-performance liquid chromatography for online renewable micro-solid-phase extraction of carbamate residues in food and environmental samples.

    PubMed

    Vichapong, Jitlada; Burakham, Rodjana; Srijaranai, Supalax; Grudpan, Kate

    2011-07-01

    A sequential injection-bead injection-lab-on-valve system was hyphenated to HPLC for online renewable micro-solid-phase extraction of carbamate insecticides. The carbamates studied were isoprocarb, methomyl, carbaryl, carbofuran, methiocarb, promecarb, and propoxur. LiChroprep(®) RP-18 beads (25-40 μm) were employed as renewable sorbent packing in a microcolumn situated inside the LOV platform mounted above the multiposition valve of the sequential injection system. The analytes sorbed by the microcolumn were eluted using 80% acetonitrile in 0.1% acetic acid before online introduction to the HPLC system. Separation was performed on an Atlantis C-18 column (4.6 × 150 mm, 5 μm) utilizing gradient elution with a flow rate of 1.0 mL/min and a detection wavelength at 270 nm. The sequential injection system offers the means of performing automated handling of sample preconcentration and matrix removal. The enrichment factors ranged between 20 and 125, leading to limits of detection (LODs) in the range of 1-20 μg/L. Good reproducibility was obtained with relative standard deviations of <0.7 and 5.4% for retention time and peak area, respectively. The developed method has been successfully applied to the determination of carbamate residues in fruit, vegetable, and water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Determination of nitrite and nitrate in water samples by an automated hydrodynamic sequential injection method.

    PubMed

    Somnam, Sarawut; Jakmunee, Jaroon; Grudpan, Kate; Lenghor, Narong; Motomizu, Shoji

    2008-12-01

    An automated hydrodynamic sequential injection (HSI) system with spectrophotometric detection was developed. Thanks to the hydrodynamic injection principle, simple devices can be used for introducing reproducible microliter volumes of both sample and reagent into the flow channel to form stacked zones in a similar fashion to those in a sequential injection system. The zones were then pushed to the detector and a peak profile was recorded. The determination of nitrite and nitrate in water samples by employing the Griess reaction was chosen as a model. Calibration graphs with linearity in the range of 0.7 - 40 muM were obtained for both nitrite and nitrate. Detection limits were found to be 0.3 muM NO(2)(-) and 0.4 muM NO(3)(-), respectively, with a sample throughput of 20 h(-1) for consecutive determination of both the species. The developed system was successfully applied to the analysis of water samples, employing simple and cost-effective instrumentation and offering higher degrees of automation and low chemical consumption.

  7. Development of enantioselective chemiluminescence flow- and sequential-injection immunoassays for alpha-amino acids.

    PubMed

    Silvaieh, Hossein; Schmid, Martin G; Hofstetter, Oliver; Schurig, Volker; Gübitz, Gerald

    2002-01-01

    The development of an enantioselective flow-through chemiluminescence immunosensor for amino acids is described. The approach is based on a competitive assay using enantioselective antibodies. Two different instrumental approaches, a flow-injection (FIA) and a sequential-injection system (SIA), are used. Compared to the flow-injection technique, the sequential injection-mode showed better repeatability. Both systems use an immunoreactor consisting of a flow cell packed with immobilized haptens. The haptens (4-amino-L- or D-phenylalanine) are immobilized onto a hydroxysuccinimide-activated polymer (Affi-prep 10) via a tyramine spacer. Stereoselective antibodies, raised against 4-amino-L- or D-phenylalanine, are labeled with an acridinium ester. Stereoselective inhibition of binding of the acridinum-labeled antibodies to the immobilized hapten by amino acids takes place. Chiral recognition was observed not only for the hapten molecule but also for a series of different amino acids. One assay cycle including regeneration takes 6:30 min in the FIA mode and 4:40 min in the SIA mode. Using D-phenylalanine as a sample, the detection limit was found to be 6.13 pmol/ml (1.01 ng/ml) for the flow-injection immunoassay (FIIA) and 1.76 pmol/ml (0.29 ng/ml ) for the sequential-injection immunoassay (SIIA) which can be lowered to 0.22 pmol/ml (0.036 ng/ml) or 0.064 pmol/ml (0.01 ng/ml) by using a stopped flow system. The intra-assay repeatability was found to be about 5% RSD and the inter-assay repeatability below 6% (within 3 days).

  8. Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system.

    PubMed

    Stefan-van Staden, Raluca-Ioana; Bokretsion, Rahel Girmai; van Staden, Jacobus F; Aboul-Enein, Hassan Y

    2006-01-01

    Carbon paste based biosensors for the determination of creatine and creatinine have been integrated into a sequential injection system. Applying the multi-enzyme sequence of creatininase (CA), and/or creatinase (CI) and sarcosine oxidase (SO), hydrogen peroxide has been detected amperometrically. The linear concentration ranges are of pmol/L to nmol/L magnitude, with very low limits of detection. The proposed SIA system can be utilized reliably for the on-line simultaneous detection of creatine and creatinine in pharmaceutical products, as well as in serum samples, with a rate of 34 samples per hour and RSD values better than 0.16% (n=10).

  9. Determination of ambroxol hydrochloride, methylparaben and benzoic acid in pharmaceutical preparations based on sequential injection technique coupled with monolithic column.

    PubMed

    Satínský, Dalibor; Huclová, Jitka; Ferreira, Raquel L C; Montenegro, Maria Conceição B S M; Solich, Petr

    2006-02-13

    The porous monolithic columns show high performance at relatively low pressure. The coupling of short monoliths with sequential injection technique (SIA) results in a new approach to implementation of separation step to non-separation low-pressure method. In this contribution, a new separation method for simultaneous determination of ambroxol, methylparaben and benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith SpeedROD RP-18e, 50-4.6 mm column with 10 mm precolumn and a FIAlab 3000 system with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-tetrahydrofuran-0.05M acetic acid (10:10:90, v/v/v), pH 3.75 adjusted with triethylamine, flow rate 0.48 mlmin(-1), UV-detection was at 245 nm. The analysis time was <11 min. A new SIC method was validated and compared with HPLC. The method was found to be useful for the routine analysis of the active compounds ambroxol and preservatives (methylparaben or benzoic acid) in various pharmaceutical syrups and drops.

  10. Monitoring lipase/esterase activity by stopped flow in a sequential injection analysis system using p-nitrophenyl butyrate.

    PubMed

    Pliego, Jorge; Mateos, Juan Carlos; Rodriguez, Jorge; Valero, Francisco; Baeza, Mireia; Femat, Ricardo; Camacho, Rosa; Sandoval, Georgina; Herrera-López, Enrique J

    2015-01-27

    Lipases and esterases are biocatalysts used at the laboratory and industrial level. To obtain the maximum yield in a bioprocess, it is important to measure key variables, such as enzymatic activity. The conventional method for monitoring hydrolytic activity is to take out a sample from the bioreactor to be analyzed off-line at the laboratory. The disadvantage of this approach is the long time required to recover the information from the process, hindering the possibility to develop control systems. New strategies to monitor lipase/esterase activity are necessary. In this context and in the first approach, we proposed a lab-made sequential injection analysis system to analyze off-line samples from shake flasks. Lipase/esterase activity was determined using p-nitrophenyl butyrate as the substrate. The sequential injection analysis allowed us to measure the hydrolytic activity from a sample without dilution in a linear range from 0.05-1.60 U/mL, with the capability to reach sample dilutions up to 1000 times, a sampling frequency of five samples/h, with a kinetic reaction of 5 min and a relative standard deviation of 8.75%. The results are promising to monitor lipase/esterase activity in real time, in which optimization and control strategies can be designed.

  11. Monitoring Lipase/Esterase Activity by Stopped Flow in a Sequential Injection Analysis System Using p-Nitrophenyl Butyrate

    PubMed Central

    Pliego, Jorge; Mateos, Juan Carlos; Rodriguez, Jorge; Valero, Francisco; Baeza, Mireia; Femat, Ricardo; Camacho, Rosa; Sandoval, Georgina; Herrera-López, Enrique J.

    2015-01-01

    Lipases and esterases are biocatalysts used at the laboratory and industrial level. To obtain the maximum yield in a bioprocess, it is important to measure key variables, such as enzymatic activity. The conventional method for monitoring hydrolytic activity is to take out a sample from the bioreactor to be analyzed off-line at the laboratory. The disadvantage of this approach is the long time required to recover the information from the process, hindering the possibility to develop control systems. New strategies to monitor lipase/esterase activity are necessary. In this context and in the first approach, we proposed a lab-made sequential injection analysis system to analyze off-line samples from shake flasks. Lipase/esterase activity was determined using p-nitrophenyl butyrate as the substrate. The sequential injection analysis allowed us to measure the hydrolytic activity from a sample without dilution in a linear range from 0.05–1.60 U/mL, with the capability to reach sample dilutions up to 1000 times, a sampling frequency of five samples/h, with a kinetic reaction of 5 min and a relative standard deviation of 8.75%. The results are promising to monitor lipase/esterase activity in real time, in which optimization and control strategies can be designed. PMID:25633600

  12. In vivo comparison of simultaneous versus sequential injection technique for thermochemical ablation in a porcine model.

    PubMed

    Cressman, Erik N K; Shenoi, Mithun M; Edelman, Theresa L; Geeslin, Matthew G; Hennings, Leah J; Zhang, Yan; Iaizzo, Paul A; Bischof, John C

    2012-01-01

    To investigate simultaneous and sequential injection thermochemical ablation in a porcine model, and compare them to sham and acid-only ablation. This IACUC-approved study involved 11 pigs in an acute setting. Ultrasound was used to guide placement of a thermocouple probe and coaxial device designed for thermochemical ablation. Solutions of 10 M acetic acid and NaOH were used in the study. Four injections per pig were performed in identical order at a total rate of 4 mL/min: saline sham, simultaneous, sequential, and acid only. Volume and sphericity of zones of coagulation were measured. Fixed specimens were examined by H&E stain. Average coagulation volumes were 11.2 mL (simultaneous), 19.0 mL (sequential) and 4.4 mL (acid). The highest temperature, 81.3°C, was obtained with simultaneous injection. Average temperatures were 61.1°C (simultaneous), 47.7°C (sequential) and 39.5°C (acid only). Sphericity coefficients (0.83-0.89) had no statistically significant difference among conditions. Thermochemical ablation produced substantial volumes of coagulated tissues relative to the amounts of reagents injected, considerably greater than acid alone in either technique employed. The largest volumes were obtained with sequential injection, yet this came at a price in one case of cardiac arrest. Simultaneous injection yielded the highest recorded temperatures and may be tolerated as well as or better than acid injection alone. Although this pilot study did not show a clear advantage for either sequential or simultaneous methods, the results indicate that thermochemical ablation is attractive for further investigation with regard to both safety and efficacy.

  13. Sequential Injection/Electrochemical Immunoassay for Quantifying the Pesticide Metabolite 3, 5, 6-Trichloro-2-Pyridinol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Guodong; Riechers, Shawn L.; Timchalk, Chuck

    2005-12-04

    An automated and sensitive sequential injection electrochemical immunoassay was developed to monitor a potential insecticide biomarker, 3, 5, 6-trichloro-2-pyridinol. The current method involved a sequential injection analysis (SIA) system equipped with a thin-layer electrochemical flow cell and permanent magnet, which was used to fix 3,5,6-trichloro-2-pyridinol (TCP) antibody coated magnetic beads (TCP-Ab-MBs) in the reaction zone. After competitive immunoreactions among TCP-Ab-MBs, TCP analyte, and horseradish peroxidase (HRP) labeled TCP, a 3, 3?, 5, 5?-tetramethylbenzidine dihydrochloride and hydrogen peroxide (TMB-H2O2) substrate solution was injected to produce an electroactive enzymatic product. The activity of HRP tracers was monitored by a square wave voltammetricmore » scanning electroactive enzymatic product in the thin-layer flow cell. The voltammetric characteristics of the substrate and the enzymatic product were investigated under batch conditions, and the parameters of the immunoassay were optimized in the SIA system. Under the optimal conditions, the system was used to measure as low as 6 ng L-1 (ppt) TCP, which is around 50-fold lower than the value indicated by the manufacturer of the TCP RaPID Assay? kit (0.25 ug/L, colorimetric detection). The performance of the developed immunoassay system was successfully evaluated on tap water and river water samples spiked with TCP. This technique could be readily used for detecting other environmental contaminants by developing specific antibodies against contaminants and is expected to open new opportunities for environmental and biological monitoring.« less

  14. Accelerated drug release and clearance of PEGylated epirubicin liposomes following repeated injections: a new challenge for sequential low-dose chemotherapy

    PubMed Central

    Yang, Qiang; Ma, Yanling; Zhao, Yongxue; She, Zhennan; Wang, Long; Li, Jie; Wang, Chunling; Deng, Yihui

    2013-01-01

    Background Sequential low-dose chemotherapy has received great attention for its unique advantages in attenuating multidrug resistance of tumor cells. Nevertheless, it runs the risk of producing new problems associated with the accelerated blood clearance phenomenon, especially with multiple injections of PEGylated liposomes. Methods Liposomes were labeled with fluorescent phospholipids of 1,2-dipalmitoyl-snglycero-3-phosphoethanolamine-N-(7-nitro-2-1,3-benzoxadiazol-4-yl) and epirubicin (EPI). The pharmacokinetics profile and biodistribution of the drug and liposome carrier following multiple injections were determined. Meanwhile, the antitumor effect of sequential low-dose chemotherapy was tested. To clarify this unexpected phenomenon, the production of polyethylene glycol (PEG)-specific immunoglobulin M (IgM), drug release, and residual complement activity experiments were conducted in serum. Results The first or sequential injections of PEGylated liposomes within a certain dose range induced the rapid clearance of subsequently injected PEGylated liposomal EPI. Of note, the clearance of EPI was two- to three-fold faster than the liposome itself, and a large amount of EPI was released from liposomes in the first 30 minutes in a complement-activation, direct-dependent manner. The therapeutic efficacy of liposomal EPI following 10 days of sequential injections in S180 tumor-bearing mice of 0.75 mg EPI/kg body weight was almost completely abolished between the sixth and tenth day of the sequential injections, even although the subsequently injected doses were doubled. The level of PEG-specific IgM in the blood increased rapidly, with a larger amount of complement being activated while the concentration of EPI in blood and tumor tissue was significantly reduced. Conclusion Our investigation implied that the accelerated blood clearance phenomenon and its accompanying rapid leakage and clearance of drug following sequential low-dose injections may reverse the unique pharmacokinetic–toxicity profile of liposomes which deserved our attention. Therefore, a more reasonable treatment regime should be selected to lessen or even eliminate this phenomenon. PMID:23576868

  15. Development of a sequential injection-square wave voltammetry method for determination of paraquat in water samples employing the hanging mercury drop electrode.

    PubMed

    dos Santos, Luciana B O; Infante, Carlos M C; Masini, Jorge C

    2010-03-01

    This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 µL s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), µA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): i(p) = (-20.5 ± 0.3)C (paraquat) - (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 µg L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.

  16. Sequential injection spectrophotometric determination of oxybenzone in lipsticks.

    PubMed

    Salvador, A; Chisvert, A; Camarasa, A; Pascual-Martí, M C; March, J G

    2001-08-01

    A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. Ethanol was also used as carrier in the SI system. Seventy-two injections per hour can be performed, which means a sample frequency of 24 h(-1) if three replicates are measured for each sample.

  17. Pre-evaluation of metal ions as a catalyst on chemiluminometric sequential injection analysis with luminol-H2O2 system.

    PubMed

    Takayanagi, Toshio; Inaba, Yuya; Kanzaki, Hiroyuki; Jyoichi, Yasutaka; Motomizu, Shoji

    2009-09-15

    Catalytic effect of metal ions on luminol chemiluminescence (CL) was investigated by sequential injection analysis (SIA). The SIA system was set up with two solenoid micropumps, an eight-port selection valve, and a photosensor module with a fountain-type chemiluminescence cell. The SIA system was controlled and the CL signals were collected by a LabVIEW program. Aqueous solutions of luminol, H(2)O(2), and a sample solution containing metal ion were sequentially aspirated to the holding coil, and the zones were immediately propelled to the detection cell. After optimizing the parameters using 1 x 10(-5)M Fe(3+) solution, catalytic effect of some metal species was compared. Among 16 metal species examined, relatively strong CL responses were obtained with Fe(3+), Fe(2+), VO(2+), VO(3)(-), MnO(4)(-), Co(2+), and Cu(2+). The limits of detection by the present SIA system were comparable to FIA systems. Permanganate ion showed the highest CL sensitivity among the metal species examined; the calibration graph for MnO(4)(-) was linear at the concentration level of 10(-8)M and the limit of detection for MnO(4)(-) was 4.0 x 10(-10)M (S/N=3).

  18. Sequential injection system with multi-parameter analysis capability for water quality measurement.

    PubMed

    Kaewwonglom, Natcha; Jakmunee, Jaroon

    2015-11-01

    A simple sequential injection (SI) system with capability to determine multi-parameter has been developed for the determination of iron, manganese, phosphate and ammonium. A simple and compact colorimeter was fabricated in the laboratory to be employed as a detector. The system was optimized for suitable conditions for determining each parameter by changing software program and without reconfiguration of the hardware. Under the optimum conditions, the methods showed linear ranges of 0.2-10 mg L(-1) for iron and manganese determinations, and 0.3-5.0 mg L(-1) for phosphate and ammonium determinations, with correlation coefficients of 0.9998, 0.9973, 0.9987 and 0.9983, respectively. The system provided detection limits of 0.01, 0.14, 0.004 and 0.02 mg L(-1) for iron, manganese, phosphate and ammonium, respectively. The proposed system has good precision, low chemical consumption and high throughput. It was applied for monitoring water quality of Ping river in Chiang Mai, Thailand. Recoveries of the analysis were obtained in the range of 82-119%. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate.

    PubMed

    Khongpet, Wanpen; Pencharee, Somkid; Puangpila, Chanida; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai; Jakmunee, Jaroon

    2018-01-15

    A microfluidic hydrodynamic sequential injection (μHSI) spectrophotometric system was designed and fabricated. The system was built by laser engraving a manifold pattern on an acrylic block and sealing with another flat acrylic plate to form a microfluidic channel platform. The platform was incorporated with small solenoid valves to obtain a portable setup for programmable control of the liquid flow into the channel according to the HSI principle. The system was demonstrated for the determination of phosphate using a molybdenum blue method. An ascorbic acid, standard or sample, and acidic molybdate solutions were sequentially aspirated to fill the channel forming a stack zone before flowing to the detector. Under the optimum condition, a linear calibration graph in the range of 0.1-6mg P L -1 was obtained. The detection limit was 0.1mgL -1 . The system is compact (5.0mm thick, 80mm wide × 140mm long), durable, portable, cost-effective, and consumes little amount of chemicals (83μL each of molybdate and ascorbic acid, 133μL of the sample solution and 1.7mL of water carrier/run). It was applied for the determination of phosphate content in extracted soil samples. The percent recoveries of the analysis were obtained in the range of 91.2-107.3. The results obtained agreed well with those of the batch spectrophotometric method. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    ERIC Educational Resources Information Center

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  1. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    ERIC Educational Resources Information Center

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  2. Sequential Injection Chromatography with an Ultra-short Monolithic Column for the Low-Pressure Separation of α-Tocopherol and γ-Oryzanol in Vegetable Oils and Nutrition Supplements.

    PubMed

    Thaithet, Sujitra; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai

    2017-01-01

    A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R s = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R 2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.

  3. Sequential injection redox or acid-base titration for determination of ascorbic acid or acetic acid.

    PubMed

    Lenghor, Narong; Jakmunee, Jaroon; Vilen, Michael; Sara, Rolf; Christian, Gary D; Grudpan, Kate

    2002-12-06

    Two sequential injection titration systems with spectrophotometric detection have been developed. The first system for determination of ascorbic acid was based on redox reaction between ascorbic acid and permanganate in an acidic medium and lead to a decrease in color intensity of permanganate, monitored at 525 nm. A linear dependence of peak area obtained with ascorbic acid concentration up to 1200 mg l(-1) was achieved. The relative standard deviation for 11 replicate determinations of 400 mg l(-1) ascorbic acid was 2.9%. The second system, for acetic acid determination, was based on acid-base titration of acetic acid with sodium hydroxide using phenolphthalein as an indicator. The decrease in color intensity of the indicator was proportional to the acid content. A linear calibration graph in the range of 2-8% w v(-1) of acetic acid with a relative standard deviation of 4.8% (5.0% w v(-1) acetic acid, n=11) was obtained. Sample throughputs of 60 h(-1) were achieved for both systems. The systems were successfully applied for the assays of ascorbic acid in vitamin C tablets and acetic acid content in vinegars, respectively.

  4. A Simple Automated Method for the Determination of Nitrate and Nitrite in Infant Formula and Milk Powder Using Sequential Injection Analysis

    PubMed Central

    Pistón, Mariela; Mollo, Alicia; Knochen, Moisés

    2011-01-01

    A fast and efficient automated method using a sequential injection analysis (SIA) system, based on the Griess, reaction was developed for the determination of nitrate and nitrite in infant formulas and milk powder. The system enables to mix a measured amount of sample (previously constituted in the liquid form and deproteinized) with the chromogenic reagent to produce a colored substance whose absorbance was recorded. For nitrate determination, an on-line prereduction step was added by passing the sample through a Cd minicolumn. The system was controlled from a PC by means of a user-friendly program. Figures of merit include linearity (r2 > 0.999 for both analytes), limits of detection (0.32 mg kg−1 NO3-N, and 0.05 mg kg−1 NO2-N), and precision (sr%) 0.8–3.0. Results were statistically in good agreement with those obtained with the reference ISO-IDF method. The sampling frequency was 30 hour−1 (nitrate) and 80 hour−1 (nitrite) when performed separately. PMID:21960750

  5. Sequential capillary electrophoresis analysis using optically gated sample injection and UV/vis detection.

    PubMed

    Liu, Xiaoxia; Tian, Miaomiao; Camara, Mohamed Amara; Guo, Liping; Yang, Li

    2015-10-01

    We present sequential CE analysis of amino acids and L-asparaginase-catalyzed enzyme reaction, by combing the on-line derivatization, optically gated (OG) injection and commercial-available UV-Vis detection. Various experimental conditions for sequential OG-UV/vis CE analysis were investigated and optimized by analyzing a standard mixture of amino acids. High reproducibility of the sequential CE analysis was demonstrated with RSD values (n = 20) of 2.23, 2.57, and 0.70% for peak heights, peak areas, and migration times, respectively, and the LOD of 5.0 μM (for asparagine) and 2.0 μM (for aspartic acid) were obtained. With the application of the OG-UV/vis CE analysis, sequential online CE enzyme assay of L-asparaginase-catalyzed enzyme reaction was carried out by automatically and continuously monitoring the substrate consumption and the product formation every 12 s from the beginning to the end of the reaction. The Michaelis constants for the reaction were obtained and were found to be in good agreement with the results of traditional off-line enzyme assays. The study demonstrated the feasibility and reliability of integrating the OG injection with UV/vis detection for sequential online CE analysis, which could be of potential value for online monitoring various chemical reaction and bioprocesses. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. SR high-speed K-edge subtraction angiography in the small animal (abstract)

    NASA Astrophysics Data System (ADS)

    Takeda, T.; Akisada, M.; Nakajima, T.; Anno, I.; Ueda, K.; Umetani, K.; Yamaguchi, C.

    1989-07-01

    To assess the ability of the high-speed K-edge energy subtraction system which was made at beamline 8C of Photon Factory, Tsukuba, we performed an animal experiment. Rabbits were used for the intravenous K-edge subtraction angiography. In this paper, the actual images of the artery obtained by this system, are demonstrated. The high-speed K-edge subtraction system consisted of movable silicon (111) monocrystals, II-ITV, and digital memory system. Image processing was performed by 68000-IP computer. The monochromatic x-ray beam size was 50×60 mm. Photon energy above and below iodine K edge was changed within 16 ms and 32 frames of images were obtained sequentially. The rabbits were anaesthetized by phenobarbital and a 5F catheter was inserted into inferior vena cava via the femoral vein. 1.5 ml/kg of contrast material (Conlaxin H) was injected at the rate of 0.5 ml/kg/s. TV images were obtained 3 s after the starting point of injection. By using this system, the clear K-edge subtracted images were obtained sequentially as a conventional DSA system. The quality of the images were better than that obtained by DSA. The dynamical blood flow was analyzed, and the best arterial image could be selected from the sequential images. The structures of aortic arch, common carotid arteries, right subclavian artery, and internal thoracic artery were obtained at the chest. Both common carotid arteries and vertebral arteries were recorded at the neck. The diameter of about 0.3-0.4 mm artery could be clearly revealed. The high-speed K-edge subtraction system demonstrates the very sharp arterial images clearly and dynamically.

  7. Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensor.

    PubMed

    Saetear, Phoonthawee; Khamtau, Kittiwut; Ratanawimarnwong, Nuanlaor; Sereenonchai, Kamonthip; Nacapricha, Duangjai

    2013-10-15

    This work presents the simultaneous determination of sucrose and phosphate by using sequential injection (SI) system with a low cost paired emitter-detector diode (PEDD) light sensor. The PEDD uses two 890 nm LEDs. Measurement of sucrose in Brix unit was carried out based on the detection of light refraction occurring at the liquid interface (the schlieren effect) between the sucrose solution and water. Phosphate was measured from the formation of calcium phosphate with turbidimetric detection. With careful design of the loading sequence and volume (sample--precipitating reagent--sample), simultaneous detection of sucrose and phosphate was accomplished with the single PEDD detector. At the optimized condition, linear calibrations from 1 to 7 Brix sucrose and from 50 to 200mg PO4(3-)L(-1) were obtained. Good precision at lower than 2% RSD (n=10) for both analytes with satisfactory throughput of 21 injections h(-1) was achieved. The method was successfully applied for the determination of sucrose and phosphate in cola drinks. The proposed method is readily applicable for automation and is found to be an alternative method to conventional procedures for on-line quality control process in cola drink industry. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  8. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    PubMed

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  9. The sequential injection system with adsorptive stripping voltammetric detection.

    PubMed

    Kubiak, W W; Latonen, R M; Ivaska, A

    2001-03-16

    Two sequential injection systems have been developed for adsorptive stripping voltammetric measurement. One is for substances adsorbing at mercury, e.g. riboflavin. In this case, a simple arrangement with only sample aspiration is needed. Reproducibility was 3% and detection limit 0.07 muM. The measuring system was applied to determination of riboflavin in vitamin pills and to study the photodegradation process of riboflavin in aqueous solutions. In the second case, metal ions were determined. They have to be complexed before deposition on the mercury surface. Thus, both the sample and the ligand have to be aspirated in the system. In this case, the reproducibility was approximately 6% and the detection limit <0.1 ppm for cadmium, lead and copper when complexation with oxine was used. Dimethylglyoxime was used in determination of nickel and cobalt and nioxime complexes were used in determination of nickel and copper. With these complexing agents, the reproducibility was the same as with oxine, but the metals could be determined at concentrations lower than 0.01 ppm. Application of two ligands in a SIA system with AdSV detection was also studied. Simultaneous determination of copper, lead, cadmium and cobalt was possible by using oxine and dimethylglyoxime. Copper and nickel were simultaneously determined by using dimethylglyoxime and nioxime.

  10. Enhanced capabilities of separation in Sequential Injection Chromatography--fused-core particle column and its comparison with narrow-bore monolithic column.

    PubMed

    Chocholouš, Petr; Kosařová, Lucie; Satínský, Dalibor; Sklenářová, Hana; Solich, Petr

    2011-08-15

    In the Sequential Injection Chromatography (SIC) only monolithic columns for chromatographic separations have been used so far. This article presents the first use of fused-core particle packed column in an attempt to extend of the chromatographic capabilities of the SIC system. A new fused-core particle column (2.7 μm) Ascentis(®) Express C18 (Supelco™ Analytical) 30 mm × 4.6 mm brings high separation efficiency within flow rates and pressures comparable to monolithic column Chromolith(®) Performance RP-18e 100-3 (Merck(®)) 100 mm × 3 mm. Both columns matches the conditions of the commercially produced SIC system - SIChrom™ (8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with 4 mL reservoir - maximal work pressure 1000 PSI) (FIAlab(®), USA). The system was tested by the separation of four estrogens with similar structure and an internal standard - ethylparaben. The mobile phase composed of acetonitrile/water (40/60 (v/v)) was pumped isocratic at flow rate 0.48 mL min(-1). Spectrophotometric detection was performed at wavelength of 225 nm and injected volume of sample solutions was 10 μL. The chromatographic characteristics of both columns were compared. Obtained results and conclusions have shown that both fused-core particle column and longer narrow shaped monolithic column bring benefits into the SIC method. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Simultaneous versus Sequential Intratympanic Steroid Treatment for Severe-to-Profound Sudden Sensorineural Hearing Loss.

    PubMed

    Yoo, Myung Hoon; Lim, Won Sub; Park, Joo Hyun; Kwon, Joong Keun; Lee, Tae-Hoon; An, Yong-Hwi; Kim, Young-Jin; Kim, Jong Yang; Lim, Hyun Woo; Park, Hong Ju

    2016-01-01

    Severe-to-profound sudden sensorineural hearing loss (SSNHL) has a poor prognosis. We aimed to compare the efficacy of simultaneous and sequential oral and intratympanic steroids for this condition. Fifty patients with severe-to-profound SSNHL (>70 dB HL) were included from 7 centers. The simultaneous group (27 patients) received oral and intratympanic steroid injections for 2 weeks. The sequential group (23 patients) was treated with oral steroids for 2 weeks and intratympanic steroids for the subsequent 2 weeks. Pure-tone averages (PTA) and word discrimination scores (WDS) were compared before treatment and 2 weeks and 1 and 2 months after treatment. Treatment outcomes according to the modified American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) criteria were also analyzed. The improvement in PTA and WDS at the 2-week follow-up was 23 ± 21 dB HL and 20 ± 39% in the simultaneous group and 31 ± 29 dB HL and 37 ± 42% in the sequential group; this was not statistically significant. Complete or partial recovery at the 2-week follow-up was observed in 26% of the simultaneous group and 30% of the sequential group; this was also not significant. The improvement in PTA and WDS at the 2-month follow-up was 40 ± 20 dB HL and 37 ± 35% in the simultaneous group and 41 ± 25 dB HL and 48 ± 41% in the sequential group; this was not statistically significant. Complete or partial recovery at the 2-month follow-up was observed in 33% of the simultaneous group and 35% of the sequential group; this was also not significant. Seven patients in the sequential group did not need intratympanic steroid injections for sufficient improvement after oral steroids alone. Simultaneous oral/intratympanic steroid treatment yielded a recovery similar to that produced by sequential treatment. Because the addition of intratympanic steroids can be decided upon based on the improvement after an oral steroid, the sequential regimen can be recommended to avoid unnecessary intratympanic injections. © 2017 S. Karger AG, Basel.

  12. Tenascin-C Prevents Articular Cartilage Degeneration in Murine Osteoarthritis Models.

    PubMed

    Matsui, Yuriyo; Hasegawa, Masahiro; Iino, Takahiro; Imanaka-Yoshida, Kyoko; Yoshida, Toshimichi; Sudo, Akihiro

    2018-01-01

    Objective The objective of this study was to determine whether intra-articular injections of tenascin-C (TNC) could prevent cartilage damage in murine models of osteoarthritis (OA). Design Fluorescently labeled TNC was injected into knee joints and its distribution was examined at 1 day, 4 days, 1 week, 2 weeks, and 4 weeks postinjection. To investigate the effects of TNC on cartilage degeneration after surgery to knee joints, articular spaces were filled with 100 μg/mL (group I), 10 μg/mL (group II) of TNC solution, or control (group III). TNC solution of 10 μg/mL was additionally injected twice after 3 weeks (group IV) or weekly after 1 week, 2 weeks, and 3 weeks (group V). Joint tissues were histologically assessed using the Mankin score and the modified Chambers system at 2 to 8 weeks after surgery. Results Exogenous TNC was maintained in the cartilage and synovium for 1 week after administration. Histological scores in groups I and II were better than scores in group III at 4 and 6 weeks, but progressive cartilage damage was seen in all groups 8 weeks postoperatively. Sequential TNC injections (groups IV and V) showed significantly better Mankin score than single injection (group II) at 8 weeks. Conclusion TNC administered exogenously remained in the cartilage of knee joints for 1 week, and could decelerate articular cartilage degeneration in murine models of OA. We also showed that sequential administration of TNC was more effective than a single injection. TNC could be an important molecule for prevention of articular cartilage damage.

  13. On-line sequential injection-capillary electrophoresis for near-real-time monitoring of extracellular lactate in cell culture flasks.

    PubMed

    Alhusban, Ala A; Gaudry, Adam J; Breadmore, Michael C; Gueven, Nuri; Guijt, Rosanne M

    2014-01-03

    Cell culture has replaced many in vivo studies because of ethical and regulatory measures as well as the possibility of increased throughput. Analytical assays to determine (bio)chemical changes are often based on end-point measurements rather than on a series of sequential determinations. The purpose of this work is to develop an analytical system for monitoring cell culture based on sequential injection-capillary electrophoresis (SI-CE) with capacitively coupled contactless conductivity detection (C(4)D). The system was applied for monitoring lactate production, an important metabolic indicator, during mammalian cell culture. Using a background electrolyte consisting of 25mM tris(hydroxymethyl)aminomethane, 35mM cyclohexyl-2-aminoethanesulfonic acid with 0.02% poly(ethyleneimine) (PEI) at pH 8.65 and a multilayer polymer coated capillary, lactate could be resolved from other compounds present in media with relative standard deviations 0.07% for intraday electrophoretic mobility and an analysis time of less than 10min. Using the human embryonic kidney cell line HEK293, lactate concentrations in the cell culture medium were measured every 20min over 3 days, requiring only 8.73μL of sample per run. Combining simplicity, portability, automation, high sample throughput, low limits of detection, low sample consumption and the ability to up- and outscale, this new methodology represents a promising technique for near real-time monitoring of chemical changes in diverse cell culture applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. A Method To Determine the Kinetics of Solute Mixing in Liquid/Liquid Formulation Dual-Chamber Syringes.

    PubMed

    Werk, Tobias; Mahler, Hanns-Christian; Ludwig, Imke Sonja; Luemkemann, Joerg; Huwyler, Joerg; Hafner, Mathias

    Dual-chamber syringes were originally designed to separate a solid substance and its diluent. However, they can also be used to separate liquid formulations of two individual drug products, which cannot be co-formulated due to technical or regulatory issues. A liquid/liquid dual-chamber syringe can be designed to achieve homogenization and mixing of both solutions prior to administration, or it can be used to sequentially inject both solutions. While sequential injection can be easily achieved by a dual-chamber syringe with a bypass located at the needle end of the syringe barrel, mixing of the two fluids may provide more challenges. Within this study, the mixing behavior of surrogate solutions in different dual-chamber syringes is assessed. Furthermore, the influence of parameters such as injection angle, injection speed, agitation, and sample viscosity were studied. It was noted that mixing was poor for the commercial dual-chamber syringes (with a bypass designed as a longitudinal ridge) when the two liquids significantly differ in their physical properties (viscosity, density). However, an optimized dual-chamber syringe design with multiple bypass channels resulted in improved mixing of liquids. Dual-chamber syringes were originally designed to separate a solid substance and its diluent. However, they can also be used to separate liquid formulations of two individual drug products. A liquid/liquid dual-chamber syringe can be designed to achieve homogenization and mixing of both solutions prior to administration, or it can be used to sequentially inject both solutions. While sequential injection can be easily achieved by a dual-chamber syringe with a bypass located at the needle end of the syringe barrel, mixing of the two fluids may provide more challenges. Within this study, the mixing behavior of surrogate solutions in different dual-chamber syringes is assessed. Furthermore, the influence of parameters such as injection angle, injection speed, agitation, and sample viscosity were studied. It was noted that mixing was poor for the commercially available dual-chamber syringes when the two liquids significantly differ in viscosity and density. However, an optimized dual-chamber syringe design resulted in improved mixing of liquids. © PDA, Inc. 2017.

  15. [Studies on a sequential injection renewable surface reflectance spectrophotometric system using a microchip flow cell].

    PubMed

    Wang, Jian-ya; Fang, Zhao-lun

    2002-02-01

    A microchip flow cell was developed for flow injection renewable surface assay by reflectance spectrophotometry. The flow cell was coupled to a sequential injection system and optical fiber photometric detection system. The flow cell featured a three-layer structure. The flow channel was cut into a silicone rubber membrance which formed the middle layer, and a porous filter was inlayed across a widened section of the channel to trap microbeads introduced into the flow cell. The area of the detection window of the flow cell was approximately 3.6 mm2, the volume of the bead trapped in the flow cell was 2.2 microL, the depth of the bead layer was 600 microns. A multistrand bifurcated optical fiber was coupled with incident light, detector and flow cell. The chromogenic reaction of Cr(VI) with 1,5-diphenylcarbohydrazide (DPC) which was adsorbed on trapped Polysorb C-18 beads was used as a model reaction to optimize the flow cell design and the experimental system. The reflectance of the renewable reaction surface was monitored at 540 nm. With 100 microL sample loaded and 1.0 mL.min-1 carrier flow rate, the linear response range was 0-0.6 microgram.mL-1 Cr(VI). A detection limit (3 sigma) of 6 ng.mL-1, precision of 1.5% RSD(n = 11), and a throughput of 64 samples per hour were achieved. Considerations in system and flow cell design, the influence of depth of the bead layer, weight of beads used, and the flow rates of carrier stream on the performance were discussed.

  16. A flow system for the spectrophotometric determination of lead in different types of waters using ion-exchange for pre-concentration and elimination of interferences.

    PubMed

    Mesquita, Raquel B R; Fernandes, Sílvia M V; Rangel, António O S S

    2004-02-06

    A flow system for the spectrophotometric determination of lead in natural and waste waters is proposed. The determination is based on the colorimetric reaction between malachite green and iodide, followed by the formation of a ternary complex between those reagents and lead cations. The developed flow system includes a lead pre-concentration step in a column packed with a cationic resin (Chelex 100) operating in a sequential injection mode. To improve the mixture of sample and reagents, a flow injection approach was adopted for the colorimetric determination. This way a hybrid flow system, involving both sequential and flow injection concepts was designed. Another feature of the proposed system is the efficient elimination of major interferent species, such as cadmium and copper. The elimination of cadmium interference is obtained by complexing Cd(2+) with chloride and retaining the formed negatively charged complexes in an anionic resin, AG1 X-8. As for copper, with the presence of both ionic resins as well as the conditions for cadmium elimination, it no longer acts as an interferent. Different ranges of lead concentration (50-300 and 300-1000mugl(-1)) can be determined with minor changes in the controlling software, useful for application to both natural and waste waters. Therefore, a detection limit of 25mugl(-1) was achieved. Repeatability was evaluated from 10 consecutive determinations being the results better than 4%. The recoveries of lead spikes added to the samples ranged from 93 to 102%. The sampling frequency was 17 and 24 determinations per hour, for 50-300 and 300-1000mugl(-1) ranges, respectively.

  17. Dynamic fractionation of trace metals in soil and sediment samples using rotating coiled column extraction and sequential injection microcolumn extraction: a comparative study.

    PubMed

    Rosende, Maria; Savonina, Elena Yu; Fedotov, Petr S; Miró, Manuel; Cerdà, Víctor; Wennrich, Rainer

    2009-09-15

    Dynamic fractionation has been recognized as an appealing alternative to conventional equilibrium-based sequential extraction procedures (SEPs) for partitioning of trace elements (TE) in environmental solid samples. This paper reports the first attempt for harmonization of flow-through dynamic fractionation using two novel methods, the so-called sequential injection microcolumn (SIMC) extraction and rotating coiled column (RCC) extraction. In SIMC extraction, a column packed with the solid sample is clustered in a sequential injection system, while in RCC, the particulate matter is retained under the action of centrifugal forces. In both methods, the leachants are continuously pumped through the solid substrates by the use of either peristaltic or syringe pumps. A five-step SEP was selected for partitioning of Cu, Pb and Zn in water soluble/exchangeable, acid-soluble, easily reducible, easily oxidizable and moderately reducible fractions from 0.2 to 0.5 g samples at an extractant flow rate of 1.0 mL min(-1) prior to leachate analysis by inductively coupled plasma-atomic emission spectrometry. Similarities and discrepancies between both dynamic approaches were ascertained by fractionation of TE in certified reference materials, namely, SRM 2711 Montana Soil and GBW 07311 sediment, and two real soil samples as well. Notwithstanding the different extraction conditions set by both methods, similar trends of metal distribution were in generally found. The most critical parameters for reliable assessment of mobilizable pools of TE in worse-case scenarios are the size-distribution of sample particles, the density of particles, the content of organic matter and the concentration of major elements. For reference materials and a soil rich in organic matter, the extraction in RCC results in slightly higher recoveries of environmentally relevant fractions of TE, whereas SIMC leaching is more effective for calcareous soils.

  18. Combined treatment in punctate inner choroidopathy

    PubMed Central

    Terelak-Borys, Barbara; Zagajewska, Katarzyna; Jankowska-Lech, Irmina; Tesla, Piotr; Grabska-Liberek, Iwona

    2016-01-01

    Purpose The purpose of this study was to describe a combination treatment for choroidal neovascular (CNV) membrane, secondary to punctate inner choroidopathy (PIC). Patient and methods A 44-year-old female patient was diagnosed with PIC complicated by the development of recurrent juxtafoveal neovascular membrane. The treatment included a sequence of monotherapy regimens: systemic steroid therapy, photodynamic therapy, and intravitreal injections of vascular endothelial growth factor (VEGF) inhibitor (anti-VEGF). Owing to the CNV membrane resistance to various types of monotherapy, a combination treatment consisting of local injections of steroid underneath the Tenon’s capsule and intravitreal anti-VEGF injections was used. Results Systemic steroid therapy resulted in rapid local improvement with a very short remission period. No positive effects of photodynamic therapy were observed. Sequential anti-VEGF injections led to remission periods of several months. Permanent regression of CNV membrane was achieved following combined local application of steroid and intravitreal anti-VEGF injections. Conclusion A combination treatment including steroid and anti-VEGF medication characterized by anti-inflammatory and antiangiogenic effects may be a very beneficial option for the treatment of recurrent CNV membrane as a complication of PIC. PMID:27729795

  19. Efficient flow injection and sequential injection methods for spectrophotometric determination of oxybenzone in sunscreens based on reaction with Ni(II).

    PubMed

    Chisvert, A; Salvador, A; Pascual-Martí, M C; March, J G

    2001-04-01

    Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LOD are adequate to the analysis requirements. The sample frequency obtained by FI is three-fold higher than that of SI analysis. SI is less reagent-consuming than FI.

  20. Brain serotonin content - Increase following ingestion of carbohydrate diet.

    NASA Technical Reports Server (NTRS)

    Fernstrom, J. D.; Wurtman, R. J.

    1971-01-01

    In the rat, the injection of insulin or the consumption of carbohydrate causes sequential increases in the concentrations of tryptophan in the plasma and the brain and of serotonin in the brain. Serotonin-containing neurons may thus participate in systems whereby the rat brain integrates information about the metabolic state in its relation to control of homeostasis and behavior.

  1. Time-lapse evaluation of human embryo development in single versus sequential culture media--a sibling oocyte study.

    PubMed

    Ciray, Haydar Nadir; Aksoy, Turan; Goktas, Cihan; Ozturk, Bilgen; Bahceci, Mustafa

    2012-09-01

    To compare the dynamics of early development between embryos cultured in single and sequential media. Randomized, comparative study. Private IVF centre. A total of 446 metaphase II oocytes from 51 couples who underwent oocyte retrieval procedure for intracytoplasmic sperm injection. Forty-nine resulted in embryo transfer. Oocytes were split between single and sequential media produced by the same manufacturer and cultured in a time-lapse incubator. Morphokinetic parameters until the embryos reached the 5-cell stage (t5), utilization, clinical pregnancy and implantation rates. Embryos cultured in single media were advanced from the first mitosis cycle and reached 2- to 5-cell stages earlier. There was not any difference between the durations for cell cycle two (cc2 = t3-t2) and s2 (t4-t3). The utilization, clinical pregnancy and implantation rates did not differ between groups. The proportion of cryopreserved day 6 embryos to two pronuclei oocytes was significantly higher in sequential than in single media. Morphokinetics of embryo development vary between single and sequential culture media at least until the 5-cell stage. The overall clinical and embryological parameters remain similar regardless of the culture system.

  2. Optimization of 64-MDCT urography: effect of dual-phase imaging with furosemide on collecting system opacification and radiation dose.

    PubMed

    Portnoy, Orith; Guranda, Larisa; Apter, Sara; Eiss, David; Amitai, Marianne Michal; Konen, Eli

    2011-11-01

    The purpose of this study was to compare opacification of the urinary collecting system and radiation dose associated with three-phase 64-MDCT urographic protocols and those associated with a split-bolus dual-phase protocol including furosemide. Images from 150 CT urographic examinations performed with three scanning protocols were retrospectively evaluated. Group A consisted of 50 sequentially registered patients who underwent a three-phase protocol with saline infusion. Group B consisted of 50 sequentially registered patients who underwent a reduced-radiation three-phase protocol with saline. Group C consisted of 50 sequentially registered patients who underwent a dual-phase split-bolus protocol that included a low-dose furosemide injection. Opacification of the urinary collecting system was evaluated with segmental binary scoring. Contrast artifacts were evaluated, and radiation doses were recorded. Results were compared by analysis of variance. A significant reduction in mean effective radiation dose was found between groups A and B (p < 0.001) and between groups B and C (p < 0.001), resulting in 65% reduction between groups A and C (p < 0.001). This reduction did not significantly affect opacification score in any of the 12 urinary segments (p = 0.079). In addition, dense contrast artifacts overlying the renal parenchyma observed with the three-phase protocols (groups A and B) were avoided with the dual-phase protocol (group C) (p < 0.001). A dual-phase protocol with furosemide injection is the preferable technique for CT urography. In comparison with commonly used three-phase protocols, the dual-phase protocol significantly reduces radiation exposure dose without reduction in image quality.

  3. Sequential determination of multi-nutrient elements in natural water samples with a reverse flow injection system.

    PubMed

    Lin, Kunning; Ma, Jian; Yuan, Dongxing; Feng, Sichao; Su, Haitao; Huang, Yongming; Shangguan, Qipei

    2017-05-15

    An integrated system was developed for automatic and sequential determination of NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ in natural waters based on reverse flow injection analysis combined with spectrophotometric detection. The system operation was controlled by a single chip microcomputer and laboratory-programmed software written in LabVIEW. The experimental parameters for each nutrient element analysis were optimized based on a univariate experimental design, and interferences from common ions were evaluated. The upper limits of the linear range (along with detection limit, µmolL -1 ) of the proposed method was 20 (0.03), 200 (0.7), 12 (0.3), 5 (0.03), 5 (0.03), 9 (0.2) µmolL -1 , for NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ , respectively. The relative standard deviations were below 5% (n=9-13) and the recoveries varied from 88.0±1.0% to 104.5±1.0% for spiked water samples. The sample throughput was about 20h -1 . This system has been successfully applied for the determination of multi-nutrient elements in different kinds of water samples and showed good agreement with reference methods (slope 1.0260±0.0043, R 2 =0.9991, n=50). Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Coupled Hydro-Mechanical Modeling of Fluid Geological Storage

    NASA Astrophysics Data System (ADS)

    Castelletto, N.; Garipov, T.; Tchelepi, H. A.

    2013-12-01

    The accurate modeling of the complex coupled physical processes occurring during the injection and the post-injection period is a key factor for assessing the safety and the feasibility of anthropogenic carbon dioxide (CO2) sequestration in subsurface formations. In recent years, it has become widely accepted the importance of the coupling between fluid flow and geomechanical response in constraining the sustainable pressure buildup caused by fluid injection relative to the caprock sealing capacity, induced seismicity effects and ground surface stability [e.g., Rutqvist, 2012; Castelletto et al., 2013]. Here, we present a modeling approach based on a suitable combination of Finite Volumes (FVs) and Finite Elements (FEs) to solve the coupled system of partial differential equations governing the multiphase flow in a deformable porous medium. Specifically, a FV method is used for the flow problem while the FE method is adopted to address the poro-elasto-plasticity equations. The aim of the present work is to compare the performance and the robustness of unconditionally stable sequential-implicit schemes [Kim et al., 2011] and the fully-implicit method in solving the algebraic systems arising from the discretization of the governing equations, for both normally conditioned and severely ill-conditioned problems. The two approaches are tested against well-known analytical solutions and experimented with in a realistic application of CO2 injection in a synthetic aquifer. References: - Castelletto N., G. Gambolati, and P. Teatini (2013), Geological CO2 sequestration in multi-compartment reservoirs: Geomechanical challenges, J. Geophys. Res. Solid Earth, 118, 2417-2428, doi:10.1002/jgrb.50180. - Kim J., H. A. Tchelepi, and R. Juanes (2011), Stability, accuracy and efficiency of sequential methods for coupled flow and geomechanics, SPE J., 16(2), 249-262. - Rutqvist J. (2012), The geomechanics of CO2 storage in deep sedimentary formations, Geotech. Geol. Eng., 30, 525-551.

  5. Drug injection into fat tissue with a laser based microjet injector

    NASA Astrophysics Data System (ADS)

    Han, Tae-hee; Hah, Jung-moo; Yoh, Jack J.

    2011-05-01

    We have investigated a new micro drug jet injector using laser pulse energy. An infrared laser beam of high energy (˜3 J/pulse) is focused inside a driving fluid in a small chamber. The pulse then induces various energy releasing processes, and generates fast microjets through a micronozzle. The elastic membrane of this system plays an important role in transferring mechanical pressure and protecting drug from heat release. In this paper, we offer the sequential images of microjet generation taken by a high speed camera as an evidence of the multiple injections via single pulse. Furthermore, we test the proposed system to penetrate soft animal tissues in order to evaluate its feasibility as an advanced transdermal drug delivery method.

  6. Recent Electrochemical and Optical Sensors in Flow-Based Analysis

    PubMed Central

    Chailapakul, Orawon; Ngamukot, Passapol; Yoosamran, Alongkorn; Siangproh, Weena; Wangfuengkanagul, Nattakarn

    2006-01-01

    Some recent analytical sensors based on electrochemical and optical detection coupled with different flow techniques have been chosen in this overview. A brief description of fundamental concepts and applications of each flow technique, such as flow injection analysis (FIA), sequential injection analysis (SIA), all injection analysis (AIA), batch injection analysis (BIA), multicommutated FIA (MCFIA), multisyringe FIA (MSFIA), and multipumped FIA (MPFIA) were reviewed.

  7. Simultaneous determination of rutin and ascorbic acid in a sequential injection lab-at-valve system.

    PubMed

    Al-Shwaiyat, Mohammed Khair E A; Miekh, Yuliia V; Denisenko, Tatyana A; Vishnikin, Andriy B; Andruch, Vasil; Bazel, Yaroslav R

    2018-02-05

    A green, simple, accurate and highly sensitive sequential injection lab-at-valve procedure has been developed for the simultaneous determination of ascorbic acid (Asc) and rutin using 18-molybdo-2-phosphate Wells-Dawson heteropoly anion (18-MPA). The method is based on the dependence of the reaction rate between 18-MPA and reducing agents on the solution pH. Only Asc is capable of interacting with 18-MPA at pH 4.7, while at pH 7.4 the reaction with both Asc and rutin proceeds simultaneously. In order to improve the precision and sensitivity of the analysis, to minimize reagent consumption and to remove the Schlieren effect, the manifold for the sequential injection analysis was supplemented with external reaction chamber, and the reaction mixture was segmented. By the reduction of 18-MPA with reducing agents one- and two-electron heteropoly blues are formed. The fraction of one-electron heteropoly blue increases at low concentrations of the reducer. Measurement of the absorbance at a wavelength corresponding to the isobestic point allows strictly linear calibration graphs to be obtained. The calibration curves were linear in the concentration ranges of 0.3-24mgL -1 and 0.2-14mgL -1 with detection limits of 0.13mgL -1 and 0.09mgL -1 for rutin and Asc, respectively. The determination of rutin was possible in the presence of up to a 20-fold molar excess of Asc. The method was applied to the determination of Asc and rutin in ascorutin tablets with acceptable accuracy and precision (1-2%). Copyright © 2017 Elsevier B.V. All rights reserved.

  8. LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes.

    PubMed

    Economou, Anastasios; Voulgaropoulos, Anastasios

    2003-01-01

    The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming of the experimental sequence was performed in LabVIEW 5.1. The sequence of operations included formation of the mercury film, electrolytic or adsorptive accumulation of the analyte on the electrode surface, recording of the voltammetric current-potential response, and cleaning of the electrode. The stripping step was carried out by applying a square-wave (SW) potential-time excitation signal to the working electrode. The instrument allowed unattended operation since multiple-step sequences could be readily implemented through the purpose-built software. The utility of the analyser was tested for the determination of copper(II), cadmium(II), lead(II) and zinc(II) by SWASV and of nickel(II), cobalt(II) and uranium(VI) by SWAdSV.

  9. LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes

    PubMed Central

    Economou, Anastasios; Voulgaropoulos, Anastasios

    2003-01-01

    The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming of the experimental sequence was performed in LabVIEW 5.1. The sequence of operations included formation of the mercury film, electrolytic or adsorptive accumulation of the analyte on the electrode surface, recording of the voltammetric current-potential response, and cleaning of the electrode. The stripping step was carried out by applying a square-wave (SW) potential-time excitation signal to the working electrode. The instrument allowed unattended operation since multiple-step sequences could be readily implemented through the purpose-built software. The utility of the analyser was tested for the determination of copper(II), cadmium(II), lead(II) and zinc(II) by SWASV and of nickel(II), cobalt(II) and uranium(VI) by SWAdSV. PMID:18924623

  10. Sequential injection system with in-line solid phase extraction and soil mini-column for determination of zinc and copper in soil leachates.

    PubMed

    Paluch, Justyna; Mesquita, Raquel B R; Cerdà, Víctor; Kozak, Joanna; Wieczorek, Marcin; Rangel, António O S S

    2018-08-01

    A sequential injection (SI) system equipped with in-line solid phase extraction column and in-line soil mini-column is proposed for determination of zinc and copper in soil leachates. The spectrophotometric determination (560 nm) is based on the reaction of both analytes with 1-(2-Pyridylazo)-2-naphthol (PAN). Zinc is determined after retaining copper on a cationic resin (Chelex100) whereas copper is determined from the difference of the absorbance measured for both analytes, introduced into the system with the use of a different channel, and zinc absorbance. The influence of several potential interferences was studied. Using the developed method, zinc and copper were determined within the concentration ranges of 0.005-0.300 and 0.011-0.200 mg L -1 , and with a relative standard deviation lower than 6.0% and 5.1%, respectively. The detection limits are 1.4 and 3.0 µg/L for determination of zinc and copper, respectively. The developed SI method was verified by the determination of both analytes in synthetic and certified reference materials of water samples, and applied to the determination of the analytes in rain water and soil leachates from laboratory scale soil core column and in-line soil mini-column. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. A LabVIEW®-based software for the control of the AUTORAD platform: a fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis.

    PubMed

    Barbesi, Donato; Vicente Vilas, Víctor; Millet, Sylvain; Sandow, Miguel; Colle, Jean-Yves; Aldave de Las Heras, Laura

    2017-01-01

    A LabVIEW ® -based software for the control of the fully automated multi-sequential flow injection analysis Lab-on-Valve (MSFIA-LOV) platform AutoRAD performing radiochemical analysis is described. The analytical platform interfaces an Arduino ® -based device triggering multiple detectors providing a flexible and fit for purpose choice of detection systems. The different analytical devices are interfaced to the PC running LabVIEW ® VI software using USB and RS232 interfaces, both for sending commands and receiving confirmation or error responses. The AUTORAD platform has been successfully applied for the chemical separation and determination of Sr, an important fission product pertinent to nuclear waste.

  12. Imaging the photoinduced charge injection in CdS/TiO2 nanoparticles by the sequential fluorescence mapping method

    NASA Astrophysics Data System (ADS)

    Frederice, Rafael; Lencione, Diego; Gehlen, Marcelo H.

    2017-03-01

    The combination of a sensitizer and TiO2 nanoparticles forming a photocatalytic material is a central issue in many fields of applied photochemistry. The charge injection of emissive sensitizers into the conduction band of the semiconductor TiO2 may form a photoactive region that becomes dark, or it has a very low emission signal due to the generation of sensitizer radicals. However, by sequential coupling of a selected photoredox dye, such as resazurin, the dark region may become fluorescent at the interfaces where the charge injection has taken place due to the concomitant formation of fluorescent resorufin by cascade electron transfer. Using this strategy and a total internal reflection fluorescence microscopy (TIRFM) image, the charge injection in TiO2/CdS and SiO2/TiO2/CdS nanoparticles is investigated The method allows the charge injection efficiency of the excited CdS into TiO2 to be evaluated qualitatively, explaining the differences observed for these photocatalytic materials in H2 generation.

  13. Imaging the photoinduced charge injection in CdS/TiO2 nanoparticles by the sequential fluorescence mapping method.

    PubMed

    Frederice, Rafael; Lencione, Diego; Gehlen, Marcelo H

    2017-02-10

    The combination of a sensitizer and TiO 2 nanoparticles forming a photocatalytic material is a central issue in many fields of applied photochemistry. The charge injection of emissive sensitizers into the conduction band of the semiconductor TiO 2 may form a photoactive region that becomes dark, or it has a very low emission signal due to the generation of sensitizer radicals. However, by sequential coupling of a selected photoredox dye, such as resazurin, the dark region may become fluorescent at the interfaces where the charge injection has taken place due to the concomitant formation of fluorescent resorufin by cascade electron transfer. Using this strategy and a total internal reflection fluorescence microscopy (TIRFM) image, the charge injection in TiO 2 /CdS and SiO 2 /TiO 2 /CdS nanoparticles is investigated The method allows the charge injection efficiency of the excited CdS into TiO 2 to be evaluated qualitatively, explaining the differences observed for these photocatalytic materials in H 2 generation.

  14. Sequential Injection Analysis for Optimization of Molecular Biology Reactions

    PubMed Central

    Allen, Peter B.; Ellington, Andrew D.

    2011-01-01

    In order to automate the optimization of complex biochemical and molecular biology reactions, we developed a Sequential Injection Analysis (SIA) device and combined this with a Design of Experiment (DOE) algorithm. This combination of hardware and software automatically explores the parameter space of the reaction and provides continuous feedback for optimizing reaction conditions. As an example, we optimized the endonuclease digest of a fluorogenic substrate, and showed that the optimized reaction conditions also applied to the digest of the substrate outside of the device, and to the digest of a plasmid. The sequential technique quickly arrived at optimized reaction conditions with less reagent use than a batch process (such as a fluid handling robot exploring multiple reaction conditions in parallel) would have. The device and method should now be amenable to much more complex molecular biology reactions whose variable spaces are correspondingly larger. PMID:21338059

  15. Speciation of chromium (VI) and total chromium determination in welding dust samples by flow-injection analysis coupled to atomic absorption spectrometry.

    PubMed

    Girard, L; Hubert, J

    1996-11-01

    We have studied the speciation of chromium (VI) in stainless-steel welding dusts. The approach used for the analysis of Cr(VI) and total Cr relies on a flow-injection analyzer (FIA) equipped with two different sequential detectors. The system measures Cr(VI). by colorimetry (with 1,5-diphenyl carbohydrazide) and total chromium content by flame atomic absorption spectroscopy (AAS). The extraction of the samples of welding-fume dusts is achieved in a buffer solution (acetic acid and sodium acetate at pH 4). This extraction procedure gives a 96% recovery of chromium (VI). The FIA-AAS system that has been described is also more sensitive, has a lower detection limit (0.005 mug ml(-1)) and gives a better precision (< 1%) than other equivalent systems that have been previously described.

  16. Sequential injection titration method using second-order signals: determination of acidity in plant oils and biodiesel samples.

    PubMed

    del Río, Vanessa; Larrechi, M Soledad; Callao, M Pilar

    2010-06-15

    A new concept of flow titration is proposed and demonstrated for the determination of total acidity in plant oils and biodiesel. We use sequential injection analysis (SIA) with a diode array spectrophotometric detector linked to chemometric tools such as multivariate curve resolution-alternating least squares (MCR-ALS). This system is based on the evolution of the basic specie of an acid-base indicator, alizarine, when it comes into contact with a sample that contains free fatty acids. The gradual pH change in the reactor coil due to diffusion and reaction phenomenona allows the sequential appearance of both species of the indicator in the detector coil, recording a data matrix for each sample. The SIA-MCR-ALS method helps to reduce the amounts of sample, the reagents and the time consumed. Each determination consumes 0.413ml of sample, 0.250ml of indicator and 3ml of carrier (ethanol) and generates 3.333ml of waste. The frequency of the analysis is high (12 samples h(-1) including all steps, i.e., cleaning, preparing and analysing). The utilized reagents are of common use in the laboratory and it is not necessary to use the reagents of perfect known concentration. The method was applied to determine acidity in plant oil and biodiesel samples. Results obtained by the proposed method compare well with those obtained by the official European Community method that is time consuming and uses large amounts of organic solvents.

  17. A novel dual-valve sequential injection manifold (DV-SIA) for automated liquid-liquid extraction. Application for the determination of picric acid.

    PubMed

    Skrlíková, Jana; Andruch, Vasil; Sklenárová, Hana; Chocholous, Petr; Solich, Petr; Balogh, Ioseph S

    2010-05-07

    A novel dual-valve sequential injection system (DV-SIA) for online liquid-liquid extraction which resolves the main problems of LLE utilization in SIA has been designed. The main idea behind this new design was to construct an SIA system by connecting two independent units, one for aqueous-organic mixture flow and the second specifically for organic phase flow. As a result, the DV-SIA manifold consists of an Extraction unit and a Detection unit. Processing a mixture of aqueous-organic phase in the Extraction unit and a separated organic phase in the Detection unit solves the problems associated with the change of phases having different affinities to the walls of the Teflon tubing used in the SI-system. The developed manifold is a simple, user-friendly and universal system built entirely from commercially available components. The system can be used for a variety of samples and organic solvents and is simple enough to be easily handled by operators less familiar with flow systems. The efficiency of the DV-SIA system is demonstrated by the extraction of picric acid in the form of an ion associate with 2-[2-(4-methoxy-phenylamino)-vinyl]-1,3,3-trimethyl-3H-indolium reagent, with subsequent spectrophotometric detection. The suggested DV-SIA concept can be expected to stimulate new experiments in analytical laboratories and can be applied to the elaboration of procedures for the determination of other compounds extractable by organic solvents. It could thus form a basis for the design of simple, single-purpose commercial instruments used in LLE procedures. 2010 Elsevier B.V. All rights reserved.

  18. Sequential elution process

    DOEpatents

    Kingsley, I.S.

    1987-01-06

    A process and apparatus are disclosed for the separation of complex mixtures of carbonaceous material by sequential elution with successively stronger solvents. In the process, a column containing glass beads is maintained in a fluidized state by a rapidly flowing stream of a weak solvent, and the sample is injected into this flowing stream such that a portion of the sample is dissolved therein and the remainder of the sample is precipitated therein and collected as a uniform deposit on the glass beads. Successively stronger solvents are then passed through the column to sequentially elute less soluble materials. 1 fig.

  19. Determination of yeast assimilable nitrogen content in wine fermentations by sequential injection analysis with spectrophotometric detetection.

    PubMed

    Muik, Barbara; Edelmann, Andrea; Lendl, Bernhard; Ayora-Cañada, María José

    2002-09-01

    An automated method for measuring the primary amino acid concentration in wine fermentations by sequential injection analysis with spectrophotometric detection was developed. Isoindole-derivatives from the primary amino acid were formed by reaction with o-phthaldialdehyde and N-acetyl- L-cysteine and measured at 334 nm with respect to a baseline point at 700 nm to compensate the observed Schlieren effect. As the reaction kinetic was strongly matrix dependent the analytical readout at the final reaction equilibrium has been evaluated. Therefore four parallel reaction coils were included in the flow system to be capable of processing four samples simultaneously. Using isoleucine as the representative primary amino acid in wine fermentations a linear calibration curve from 2 to 10 mM isoleucine, corresponding to 28 to 140 mg nitrogen/L (N/L) was obtained. The coefficient of variation of the method was 1.5% at a throughput of 12 samples per hour. The developed method was successfully used to monitor two wine fermentations during alcoholic fermentation. The results were in agreement with an external reference method based on high performance liquid chromatography. A mean-t-test showed no significant differences between the two methods at a confidence level of 95%.

  20. Split Flow Online Solid-Phase Extraction Coupled with Inductively Coupled Plasma Mass Spectrometry System for One-Shot Data Acquisition of Quantification and Recovery Efficiency.

    PubMed

    Furukawa, Makoto; Takagai, Yoshitaka

    2016-10-04

    Online solid-phase extraction (SPE) coupled with inductively coupled plasma mass spectrometry (ICPMS) is a useful tool in automatic sequential analysis. However, it cannot simultaneously quantify the analytical targets and their recovery percentages (R%) in one-shot samples. We propose a system that simultaneously acquires both data in a single sample injection. The main flowline of the online solid-phase extraction is divided into main and split flows. The split flow line (i.e., bypass line), which circumvents the SPE column, was placed on the main flow line. Under program-controlled switching of the automatic valve, the ICPMS sequentially measures the targets in a sample before and after column preconcentration and determines the target concentrations and the R% on the SPE column. This paper describes the system development and two demonstrations to exhibit the analytical significance, i.e., the ultratrace amounts of radioactive strontium ( 90 Sr) using commercial Sr-trap resin and multielement adsorbability on the SPE column. This system is applicable to other flow analyses and detectors in online solid phase extraction.

  1. Sequential variable fuel injection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weglarz, M.W.; Vincent, M.T.; Prestel, J.F.

    This patent describes a fuel injection system for an engine of an automotive vehicle including cylinders, a spark plug for each of the cylinders, a distributor electrically connected to the spark plug, a throttle body having a throttle valve connected to the engine to allow or prevent air to the cylinders, a fuel source at least one fuel line connected to the fuel source, fuel injectors connected to the fuel line for delivering fuel to the cylinders, a sensor located near the distributor for sensing predetermined states of the distributor, and an electronic control unit (ECU) electrically connected to themore » sensor, distributor and fuel injectors. It comprises calculating a desired total injector on time for current engine conditions; calculating a variable injection time (VIT) and a turn on time based on the VIT; and firing the fuel injectors at the calculated turn on time for the calculated total injector on time.« less

  2. Dual nozzle single pump fuel injection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, C.

    1992-02-25

    This patent describes an improvement in a fuel injection system in a stratified charge hybrid internal combustion engine including a main combustion chamber, a precombustion chamber connected with the main chamber, fuel injectors in the main combustion chamber and precombustion chamber which open at higher and lower pressure levels respectively to sequentially inject fuel into the prechamber and the main chamber, timed spark ignition means in the prechamber for ignition of the fuel-air mixture therein, and an engine driven and timed fuel injection pump having a variable output capacity that varies with power level position, the injection pump is suppliedmore » by a low pressure charging pump. The improvement comprises: a shuttle valve including a bore therein; a shuttle spool means positioned within the bore defining a prechamber supply chamber on one side thereof and a spool activation chamber on the opposite side thereof the spool means having a first and second position; biasing means urging the spool towards it first position with the spool actuation chamber at its minimum volume; first conduit means connecting charging pressure to the prechamber supply camber in the first position oil the spool means; second conduit means connecting the injection pump to spool actuation chamber; third conduit means connecting the spool actuating chamber with the main injector; forth conduit means connecting the prechamber supply chamber with the prechamber injector; the initial charge from the injection pump actuates the spool means from its fir to its second position.« less

  3. A new rat model of portal hypertension induced by intraportal injection of microspheres

    PubMed Central

    Li, Xiang-Nong; Benjamin, IS; Alexander, B

    1998-01-01

    AIM: To produce a new rat model of portal hypertension by intraportal injection of microspheres. METHODS: Measured aliquots of single or different-sized microspheres (15, 40, 80μm) were injected into the portal vein to block intrahepatic portal radicals. The resultant changes in arterial,portal,hepatic venous and splenic pulp pressures were monitored. The liver and lungs were excised for histological examination. RESULTS: Portal venous pressure was elevated from basal value of 0.89-1.02 kPa to a steady-state of 1.98-3.19 kPa following the sequential injections of single- or different-sized microspheres, with a markedly lowered mean arterial pressure. However, a small-dose injection of 80 μm microspheres (1.8 × 105) produced a steady-state portal venous pressure of 2.53 × 0.17 kPa, and all rats showed normal arterial pressures. In addition, numerous microspheres were found in the lungs in all experimental groups. CONCLUSION: Portal hypertension can be reproduced in rats by intraportal injection of microspheres at a small dose of 80 μm (1.8 × 105). Intrahepatic portal-systemic shunts probably exist in the normal rat liver. PMID:11819236

  4. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    PubMed

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Deltoid Injections of Risperidone Long-acting Injectable in Patients with Schizophrenia

    PubMed Central

    Quiroz, Jorge A.; Rusch, Sarah; Thyssen, An; Kushner, Stuart

    2011-01-01

    Background Risperidone long-acting injectable was previously approved for treatment of schizophrenia as biweekly injections in the gluteal muscle only. We present data on local injection-site tolerability and safety of risperidone long-acting injectable and comparability of systemic exposure of deltoid versus gluteal injections. Methods Risperidone long-acting injectable was administered in an open-label, single-dose, two-way crossover study, with patients randomized to receive either 25mg gluteal/37.5mg deltoid crossover in two treatment periods or 50mg gluteal/50mg deltoid injections crossover; each treatment period was separated by an 85-day observation period (Study 1) and an open-label, multiple-dose study (4 sequential 37.5mg or 50mg deltoid injections every 2 weeks) (Study 2). The pharmacokinetic results from both the studies have already been published. Results In Study 1 (n=170), the majority of patients had no local injection-site findings, based on investigator and patient-rated evaluations. In Study 2 (n=53), seven of the 51 patients who received at least two deltoid injections discontinued (primary endpoint). However, none of the discontinuations were due to injection-site related reasons. The 90-percent upper confidence limit of the true proportion of injection-site issue withdrawals was 5.7 percent. No moderate or severe injection-site reactions were reported. Conclusion Intramuscular injections via the deltoid and gluteal sites are equivalent routes of administration of risperidone long-acting injectable with respect to local injection-site tolerability. The overall safety and tolerability profile of risperidone long-acting injectable was comparable when administered as an intramuscular injection in the deltoid (37.5mg and 50mg) and gluteal (25mg and 50mg) sites. PMID:21779538

  6. Comparison of simultaneous and sequential administration of fentanyl-propofol for surgical abortion: a randomized single-blinded controlled trial.

    PubMed

    Gao, Wei; Sha, Baoyong; Zhao, Yuan; Fan, Zhe; Liu, Lin; Shen, Xin

    2017-08-01

    Propofol lipid emulsion (PLE) is a nanosized sedative, and it is used with a combination of salted antalgic prodrug, fentanyl citrate (FC). To illustrate the synergistic effect of mixing, we compared the sedation/analgesia resulting from simultaneous and sequential administration in surgically induced abortion (No. ChiCTR-IPC-15006153). Simultaneous group showed lower bispectral index, blood pressure, and heart rate, when cannula was inserted into the uterus. It also showed less frequency of hypertension, sinus tachycardia, movement, pain at the injection site, and additional FC. Therefore, premixing of PLE and FC enhanced the sedation and analgesia; stabilized the hemodynamics; lessened the incidence of movement and injection pain; and reduced the requirement of drugs.

  7. Sequential Systemic Administrations of Combretastatin A4 Phosphate and Radioiodinated Hypericin Exert Synergistic Targeted Theranostic Effects with Prolonged Survival on SCID Mice Carrying Bifocal Tumor Xenografts

    PubMed Central

    Li, Junjie; Cona, Marlein Miranda; Chen, Feng; Feng, Yuanbo; Zhou, Lin; Zhang, Guozhi; Nuyts, Johan; de Witte, Peter; Zhang, Jian; Yu, Jie; Oyen, Raymond; Verbruggen, Alfons; Ni, Yicheng

    2013-01-01

    Objectives: Based on the soil-to-seeds principle, we explored the small-molecular sequential dual-targeting theranostic strategy (SMSDTTS) for prolonged survival and imaging detectability in a xenograft tumor model. Materials and Methods: Thirty severe combined immunodeficiency (SCID) mice bearing bilateral radiation-induced fibrosarcoma-1 (RIF-1) subcutaneously were divided into group A of SMSDTTS with sequential intravenous injections of combretastatin A4 phosphate (CA4P) and 131I-iodohypericin (131I-Hyp) at a 24 h interval; group B of single targeting control with CA4P and vehicle of 131I-Hyp; and group C of vehicle control (10 mice per group). Tumoricidal events were monitored by in vivo magnetic resonance imaging (MRI) and planar gamma scintiscan, and validated by ex vivo autoradiography and histopathology. Besides, 9 mice received sequential intravenous injections of CA4P and 131I-Hyp were subjected to biodistribution analysis at 24, 72 and 120 h. Results: Gamma counting revealed fast clearance of 131I-Hyp from normal organs but intense accumulation in necrotic tumor over 120 h. After only one treatment, significantly prolonged survival (p<0.001) was found in group A compared to group B and C with median survival of 33, 22, and 21 days respectively. Tumor volume on day 15 was 2.0 ± 0.89, 5.66 ± 1.66, and 5.02 ± 1.0 cm3 with tumor doubling time 7.8 ± 2.8, 4.4 ± 0.67, and 4.5 ± 0.5 days respectively. SMSDTTS treated tumors were visualized as hot spots on gamma scintiscans, and necrosis over tumor ratio remained consistently high on MRI, autoradiography and histology. Conclusion: The synergistic antitumor effects, multifocal targetability, simultaneous theranostic property, and good tolerance of the SMSDTTS were evident in this experiment, which warrants further development for preclinical and clinical applications. PMID:23423247

  8. Simultaneous injection-effective mixing analysis of palladium.

    PubMed

    Teshima, Norio; Noguchi, Daisuke; Joichi, Yasutaka; Lenghor, Narong; Ohno, Noriko; Sakai, Tadao; Motomizu, Shoji

    2010-01-01

    A novel concept of simultaneous injection-effective mixing analysis (SIEMA) is proposed, and a SIEMA method applied to the spectrophotometric determination of palladium using a water-soluble chromogenic reagent has been demonstrated. The flow configuration of SIEMA is a hybrid format of flow injection analysis (FIA), sequential injection analysis (SIA) and multicommutation in flow-based analysis. Sample and reagent solutions are aspirated into each holding coil through each solenoid valve by a syringe pump, and then the zones are simultaneously dispensed (injected) into a mixing coil by reversed flow toward a detector through a confluence point. This results in effective mixing and rapid detection with low reagent consumption.

  9. Differential effects of progesterone and genital stimulation on sequential inhibition of estrous behavior and progesterone receptor expression in the rat brain.

    PubMed

    Gómez-Camarillo, Madaí A; Beyer, Carlos; Lucio, Rosa Angélica; García-Juárez, Marcos; González-Arenas, Aliesha; Camacho-Arroyo, Ignacio; Komisaruk, Barry R; González-Flores, Oscar

    2011-05-30

    The effect of genital stimulation, either by vaginocervical stimulation (VCS) using a calibrated vaginal probe combined with manual flank stimulation (FS), or by mounts performed by the male, on the hypothalamus and preoptic area concentration of the progesterone receptors A (PR-A) and B (PR-B) was assessed in ovariectomized (ovx) estrogen-primed rats. VCS/FS or stimulation provided by male mounts, even without intromission, significantly decreased PR-B concentration in the hypoythalamus. Down regulation of PR produced by genital stimulation was quantitatively similar to that elicited by progesterone (P) administration. Bilateral or unilateral transection of the pelvic or the pudendal nerves prevented down regulation elicited by VCS/FS. Repeated VCS/FS elicited lordosis behavior in most ovx estrogen primed rats, but the lordosis intensity was lower than that observed in response to P. P administered to ovx estrogen primed rats, induced sequential inhibition, i.e., failure to display estrous behavior in response to a second P injection (24h after the initial P injection). VCS/FS failed to elicit sequential inhibition, since rats responded with normal estrous behavior to the second injection of P. This suggests that down regulation by VCS, by contrast with P, failed to inhibit the subpopulation of PR involved in the facilitation of estrous behavior by P. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. A Telescopic and Microscopic Examination of Acceleration in the June 2015 Geomagnetic Storm: Magnetospheric Multiscale and Van Allen Probes Study of Substorm Particle Injection

    NASA Technical Reports Server (NTRS)

    Baker, D. N.; Jaynes, A. N.; Turner, D. L.; Nakamura, R.; Schmid, D.; Mauk, B. H.; Cohen, I. J.; Fennell, J. F.; Blake, J. B.; Strangeway, R. J.; hide

    2016-01-01

    An active storm period in June 2015 showed that particle injection events seen sequentially by the four (MagnetosphericMultiscale) MMS spacecraft subsequently fed the enhancement of the outer radiation belt observed by Van Allen Probes mission sensors. Several episodes of significant southward interplanetary magnetic field along with a period of high solar wind speed (Vsw 500kms) on 22 June occurred following strong interplanetary shock wave impacts on the magnetosphere. Key events on 22 June 2015 show that the magnetosphere progressed through a sequence of energy-loading and stress-developing states until the entire system suddenly reconfigured at 19:32 UT. Energetic electrons, plasma, and magnetic fields measured by the four MMS spacecraft revealed clear dipolarization front characteristics. It was seen that magnetospheric substorm activity provided a seed electron population as observed by MMS particle sensors as multiple injections and related enhancements in electron flux.

  11. Sequential injection gas guns for accelerating projectiles

    DOEpatents

    Lacy, Jeffrey M [Idaho Falls, ID; Chu, Henry S [Idaho Falls, ID; Novascone, Stephen R [Idaho Falls, ID

    2011-11-15

    Gas guns and methods for accelerating projectiles through such gas guns are described. More particularly, gas guns having a first injection port located proximate a breech end of a barrel and a second injection port located longitudinally between the first injection port and a muzzle end of the barrel are described. Additionally, modular gas guns that include a plurality of modules are described, wherein each module may include a barrel segment having one or more longitudinally spaced injection ports. Also, methods of accelerating a projectile through a gas gun, such as injecting a first pressurized gas into a barrel through a first injection port to accelerate the projectile and propel the projectile down the barrel past a second injection port and injecting a second pressurized gas into the barrel through the second injection port after passage of the projectile and to further accelerate the projectile are described.

  12. Energetic electron injections and dipolarization events in Mercury's magnetotail: Substorm dynamics

    NASA Astrophysics Data System (ADS)

    Dewey, R. M.; Slavin, J. A.; Raines, J. M.; Imber, S.; Baker, D. N.; Lawrence, D. J.

    2017-12-01

    Despite its small size, Mercury's terrestrial-like magnetosphere experiences brief, yet intense, substorm intervals characterized by features similar to at Earth: loading/unloading of the tail lobes with open magnetic flux, dipolarization of the magnetic field at the inner edge of the plasma sheet, and, the focus of this presentation, energetic electron injection. We use the Gamma-Ray Spectrometer's high-time resolution (10 ms) energetic electron measurements to determine the relationship between substorm activity and energetic electron injections coincident with dipolarization fronts in the magnetotail. These dipolarizations were detected on the basis of their rapid ( 2 s) increase in the northward component of the tail magnetic field (ΔBz 30 nT), which typically persists for 10 s. We estimate the typical flow channel to be 0.15 RM, planetary convection speed of 750 km/s, cross-tail potential drop of 7 kV, and flux transport of 0.08 MWb for each dipolarization event, suggesting multiple simultaneous and sequential dipolarizations are required to unload the >1 MWb of magnetic flux typically returned to the dayside magnetosphere during a substorm interval. Indeed, while we observe most dipolarization-injections to be isolated or in small chains of events (i.e., 1-3 events), intervals of sawtooth-like injections with >20 sequential events are also present. The typical separation between dipolarization-injection events is 10 s. Magnetotail dipolarization, in addition to being a powerful source of electron acceleration, also plays a significant role in the substorm process at Mercury.

  13. Electrochemical immunoassay for vitellogenin based on sequential injection using antigen-immobilized magnetic microbeads.

    PubMed

    Hirakawa, Koji; Katayama, Masaaki; Soh, Nobuaki; Nakano, Koji; Imato, Toshihiko

    2006-01-01

    A rapid and sensitive immunoassay for the determination of vitellogenin (Vg) is described. The method involves a sequential injection analysis (SIA) system equipped with an amperometric detector and a neodymium magnet. Magnetic beads, onto which an antigen (Vg) was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of magnetic beads in an immunoreaction cell were controlled by means of the neodymium magnet and by adjusting the flow of the carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an alkaline phosphatase (ALP) labeled anti-Vg monoclonal antibody between the fraction of Vg immobilized on the magnetic beads and Vg in the sample solution. The immobilization of Vg on the beads involved coupling an amino group moiety of Vg with the magnetic beads after activation of a carboxylate moiety on the surface of magnetic beads that had been coated with a polylactate film. The Vg-immobilized magnetic beads were introduced and trapped in the immunoreaction cell equipped with the neodymium magnet; a Vg sample solution containing an ALP labeled anti-Vg antibody at a constant concentration and a p-aminophenyl phosphate (PAPP) solution were sequentially introduced into the immunoreaction cell. The product of the enzyme reaction of PAPP with ALP on the antibody, paminophenol, was transported to an amperometric detector, the applied voltage of which was set at +0.2 V vs. an Ag/AgCl reference electrode. A sigmoid calibration curve was obtained when the logarithm of the concentration of Vg was plotted against the peak current of the amperometric detector using various concentrations of standard Vg sample solutions (0-500 ppb). The time required for the analysis is less than 15 min.

  14. Design of LabVIEW®-based software for the control of sequential injection analysis instrumentation for the determination of morphine

    PubMed Central

    Lenehan, Claire E.; Lewis, Simon W.

    2002-01-01

    LabVIEW®-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 × 10-10 to 5 × 10-6 M) with a line of best fit of y=1.05x+8.9164 (R2 =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 × 10-8 M). The limit of detection (3σ) was determined as 5 × 10-11 M morphine. PMID:18924729

  15. Design of LabVIEW-based software for the control of sequential injection analysis instrumentation for the determination of morphine.

    PubMed

    Lenehan, Claire E; Barnett, Neil W; Lewis, Simon W

    2002-01-01

    LabVIEW-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 x 10(-10) to 5 x 10(-6) M) with a line of best fit of y=1.05(x)+8.9164 (R(2) =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 x 10(-8) M). The limit of detection (3sigma) was determined as 5 x 10(-11) M morphine.

  16. Single peak parameters technique for simultaneous measurements: Spectrophotometric sequential injection determination of Fe(II) and Fe(III).

    PubMed

    Kozak, J; Paluch, J; Węgrzecka, A; Kozak, M; Wieczorek, M; Kochana, J; Kościelniak, P

    2016-02-01

    Spectrophotometric sequential injection system (SI) is proposed to automate the method of simultaneous determination of Fe(II) and Fe(III) on the basis of parameters of a single peak. In the developed SI system, sample and mixture of reagents (1,10-phenanthroline and sulfosalicylic acid) are introduced into a vessel, where in an acid environment (pH≅3) appropriate compounds of Fe(II) and Fe(III) with 1,10-phenanthroline and sulfosalicylic acid are formed, respectively. Then, in turn, air, sample, EDTA and sample again, are introduced into a holding coil. After the flow reversal, a segment of air is removed from the system by an additional valve and as EDTA replaces sulfosalicylic acid forming a more stable colorless compound with Fe(III), a complex signal is registered. Measurements are performed at wavelength 530 nm. The absorbance measured at minimum of the negative peak and the area or the absorbance measured at maximum of the signal can be used as measures corresponding to Fe(II) and Fe(III) concentrations, respectively. The time of the peak registration is about 2 min. Two-component calibration has been applied to analysis. Fe(II) and Fe(III) can be determined within the concentration ranges of 0.04-4.00 and 0.1-5.00 mg L(-1), with precision less than 2.8% and 1.7% (RSD), respectively and accuracy better than 7% (RE). The detection limit is 0.04 and 0.09 mg L(-1) for Fe(II) and Fe(III), respectively. The method was applied to analysis of artesian water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. A 1000+ channel bionic communication system.

    PubMed

    Schulman, Joseph H; Mobley, J Phil; Wolfe, James; Stover, Howard; Krag, Adrian

    2006-01-01

    The wireless electronic nervous system interface known as the functional electrical stimulation-battery powered bion system is being developed at the Alfred Mann Foundation. It contains a real-time propagated wave micro-powered multichannel communication system. This system is designed to send bi-directional messages between an external master controller unit (MCU), and each one of a group of injectable stimulator-sensor battery powered bion implants (BPB). The system is capable of communicating in each direction about 90 times per second using a structure of 850 time slots within a repeating 11 millisecond time window. The system's total Time Division Multiple Access (TDMA) communication capability is about 77,000 two-way communications per second on a single 5 MHz wide radio channel. Each time slot can be used by one BPB, or shared alternately by two or more BPBs. Each bidirectional communication consists of a 15 data bit message sent from the MCU sequentially to each BPB and 10 data bit message sent sequentially from each BPB to the MCU. Redundancy bits are included to provide error detection and correction. This communication system is designed to draw only a few microamps from the 3.6 volt, 3.0 mAHr lithium ion (LiIon) battery contained in each BPB, and the majority of the communications circuitry is contained within a 1.4x5 mm integrated circuit.

  18. Application of silver nanoparticles to the chemiluminescence determination of cefditoren pivoxil using the luminol-ferricyanide system.

    PubMed

    Alarfaj, Nawal A; Aly, Fatma A; El-Tohamy, Maha F

    2015-02-01

    A new simple, accurate and sensitive sequential injection analysis chemiluminescence (CL) detection method for the determination of cefditoren pivoxil (CTP) has been developed. The developed method was based on the enhancement effect of silver nanoparticles on the CL signal arising from a luminol-potassium ferricyanide reaction in the presence of CTP. The optimum conditions relevant to the effect of luminol, potassium ferricyanide and silver nanoparticle concentrations were investigated. The proposed method showed linear relationships between relative CL intensity and the investigated drug concentration at the range 0.001-5000 ng/mL, (r = 0.9998, n = 12) with a detection limit of 0.5 pg/mL and quantification limit of 0.001 ng/mL. The relative standard deviation was 1.6%. The proposed method was employed for the determination of CTP in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated. In addition, the interference of some related cephalosporins was tested. No interference was recorded. The obtained sequential injection analysis-CL results were statistically compared with those from a reported method and did not show any significant differences. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Analysis of Anthrax Immune Globulin Intravenous with Antimicrobial Treatment in Injection Drug Users, Scotland, 2009-2010.

    PubMed

    Cui, Xizhong; Nolen, Leisha D; Sun, Junfeng; Booth, Malcolm; Donaldson, Lindsay; Quinn, Conrad P; Boyer, Anne E; Hendricks, Katherine; Shadomy, Sean; Bothma, Pieter; Judd, Owen; McConnell, Paul; Bower, William A; Eichacker, Peter Q

    2017-01-01

    We studied anthrax immune globulin intravenous (AIG-IV) use from a 2009-2010 outbreak of Bacillus anthracis soft tissue infection in injection drug users in Scotland, UK, and we compared findings from 15 AIG-IV recipients with findings from 28 nonrecipients. Death rates did not differ significantly between recipients and nonrecipients (33% vs. 21%). However, whereas only 8 (27%) of 30 patients at low risk for death (admission sequential organ failure assessment score of 0-5) received AIG-IV, 7 (54%) of the 13 patients at high risk for death (sequential organ failure assessment score of 6-11) received treatment. AIG-IV recipients had surgery more often and, among survivors, had longer hospital stays than did nonrecipients. AIG-IV recipients were sicker than nonrecipients. This difference and the small number of higher risk patients confound assessment of AIG-IV effectiveness in this outbreak.

  20. Drug delivery into the cochlear apex: Improved control to sequentially affect finely spaced regions along the entire length of the cochlear spiral.

    PubMed

    Lichtenhan, J T; Hartsock, J; Dornhoffer, J R; Donovan, K M; Salt, A N

    2016-11-01

    Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Drug delivery into the cochlear apex: Improved control to sequentially affect finely spaced regions along the entire length of the cochlear spiral

    PubMed Central

    Lichtenhan, JT; Hartsock, J; Dornhoffer, JR; Donovan, KM; Salt, AN

    2016-01-01

    Background Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. New method Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Results Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Conclusions Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. PMID:27506463

  2. Spectrophotometric determination of sulphate in automotive fuel ethanol by sequential injection analysis using dimethylsulphonazo(III) reaction.

    PubMed

    de Oliveira, Fabio Santos; Korn, Mauro

    2006-01-15

    A sensitive SIA method was developed for sulphate determination in automotive fuel ethanol. This method was based on the reaction of sulphate with barium-dimethylsulphonazo(III) leading to a decrease on the magnitude of analytical signal monitored at 665 nm. Alcohol fuel samples were previously burned up to avoid matrix effects for sulphate determinations. Binary sampling and stop-flow strategies were used to increase the sensitivity of the method. The optimization of analytical parameter was performed by response surface method using Box-Behnker and central composite designs. The proposed sequential flow procedure permits to determine up to 10.0mg SO(4)(2-)l(-1) with R.S.D. <2.5% and limit of detection of 0.27 mg l(-1). The method has been successfully applied for sulphate determination in automotive fuel alcohol and the results agreed with the reference volumetric method. In the optimized condition the SIA system carried out 27 samples per hour.

  3. Electrochemical immunoassay on a microfluidic device with sequential injection and flushing functions.

    PubMed

    Nashida, Norihiro; Satoh, Wataru; Fukuda, Junji; Suzuki, Hiroaki

    2007-06-15

    An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human alpha-fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.

  4. Two-column sequential injection chromatography--new approach for fast and effective analysis and its comparison with gradient elution chromatography.

    PubMed

    Chocholous, Petr; Satínský, Dalibor; Sklenárová, Hana; Solich, Petr

    2010-05-23

    This work presents novel approach in low-pressure chromatography flow systems--two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab, USA) with two commercially available monolithic columns the "first column" Chromolith Flash RP-18e (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith RP-18e (10 mm x 4.6 mm i.d.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 microL of filtered supernatant was injected on each column (2 x 10 microL). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 microg mL(-1) for paracetamol, at 0.5 microg mL(-1) for caffeine and at 0.7 microg mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.). Copyright 2010 Elsevier B.V. All rights reserved.

  5. Three-Dimensional Changes in the Midface Following Malar Calcium Hydroxyapatite Injection in a Cadaver Model.

    PubMed

    Gatherwright, James R; Brown, Matthew S; Katira, Kristopher M; Rowe, David J

    2015-08-01

    Three-dimensional (3D) changes in the midface following malar calcium hydroxyapatite (CaHa) injection have not been systematically analyzed. The authors analyzed 3D volume changes in midface and naso-labial fold (NLF) volume, as well as lateral movement in the NLF/naso-labial crease (NLC) junction following malar injection of CaHa in a cadaver model. A single surgeon injected CaHa in the supraperiosteal plane. Sequential images were obtained with the VECTRA 3D system pre- and post-1.5- and 3-cc CaHa injections. All measurements were performed by a single examiner. Injection location was verified anatomically. Injections were performed in 16 fresh cadaver hemi-faces. Maximal increases in projection were centered on the malar injection site, with associated decreases in projection and volume in the infero-medial locations. Relative mean increases in volume of 3.16 cc and 4.94 cc were observed following the 1.5-cc and 3-cc injections, respectively. There was a relative decrease in the volume of the NLF of -0.3 cc and -0.4 cc following the 1.5- and 3-cc injections, respectively. Injection of CaHa was associated with lateral movements of the NLF-NLC junction at the level of the nasal sill, philtral columns, and oral commissure, measuring 2.7, 2.5, and 1.9 mm and 2.8, 2.9, and 2.4 mm following the 1.5- and 3-cc injections, respectively. Anatomical dissection verified the location in the supraperiosteal space and within the middle malar fat pad. Following malar CaHa injection, 3D photographic analysis showed a measureable lifting effect with recruitment of ptotic tissue and lateral movement of the NLF-NLC junction in a cadaver model. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  6. Automatic weld torch guidance control system

    NASA Technical Reports Server (NTRS)

    Smaith, H. E.; Wall, W. A.; Burns, M. R., Jr.

    1982-01-01

    A highly reliable, fully digital, closed circuit television optical, type automatic weld seam tracking control system was developed. This automatic tracking equipment is used to reduce weld tooling costs and increase overall automatic welding reliability. The system utilizes a charge injection device digital camera which as 60,512 inidividual pixels as the light sensing elements. Through conventional scanning means, each pixel in the focal plane is sequentially scanned, the light level signal digitized, and an 8-bit word transmitted to scratch pad memory. From memory, the microprocessor performs an analysis of the digital signal and computes the tracking error. Lastly, the corrective signal is transmitted to a cross seam actuator digital drive motor controller to complete the closed loop, feedback, tracking system. This weld seam tracking control system is capable of a tracking accuracy of + or - 0.2 mm, or better. As configured, the system is applicable to square butt, V-groove, and lap joint weldments.

  7. Microcellular injection molding process for producing lightweight thermoplastic polyurethane with customizable properties

    NASA Astrophysics Data System (ADS)

    Ellingham, Thomas; Kharbas, Hrishikesh; Manitiu, Mihai; Scholz, Guenter; Turng, Lih-Sheng

    2018-03-01

    A three-stage molding process involving microcellular injection molding with core retraction and an "out-of-mold" expansion was developed to manufacture thermoplastic polyurethane into lightweight foams of varying local densities, microstructures, and mechanical properties in the same microcellular injection molded part. Two stages of cavity expansion through sequential core retractions and a third expansion in a separate mold at an elevated temperature were carried out. The densities varied from 0.25 to 0.42 g/cm3 (77% to 62% weight reduction). The mechanical properties varied as well. Cyclic compressive strengths and hysteresis loss ratios, together with the microstructures, were characterized and reported.

  8. Efficient spin-current injection in single-molecule magnet junctions

    NASA Astrophysics Data System (ADS)

    Xie, Haiqing; Xu, Fuming; Jiao, Hujun; Wang, Qiang; Liang, J.-Q.

    2018-01-01

    We study theoretically spin transport through a single-molecule magnet (SMM) in the sequential and cotunneling regimes, where the SMM is weakly coupled to one ferromagnetic and one normal-metallic leads. By a master-equation approach, it is found that the spin polarization injected from the ferromagnetic lead is amplified and highly polarized spin-current can be generated, due to the exchange coupling between the transport electron and the anisotropic spin of the SMM. Moreover, the spin-current polarization can be tuned by the gate or bias voltage, and thus an efficient spin injection device based on the SMM is proposed in molecular spintronics.

  9. Automated solid-phase extraction hyphenated to voltammetry for the determination of quercetin using magnetic nanoparticles and sequential injection lab-on-valve approach.

    PubMed

    Wang, Yang; Wang, Lu; Tian, Tian; Hu, Xiaoya; Yang, Chun; Xu, Qin

    2012-05-21

    In this study, an automated sequential injection lab-on-valve (SI-LOV) system was designed for the on-line matrix removal and preconcentration of quercetin. Octadecyl functionalized magnetic silica nanoparticles were prepared and packed into the microcolumn of the LOV as adsorbents. After being adsorbed through hydrophobic interaction, the analyte was eluted and subsequently introduced into the electrochemical flow cell by voltammetric quantification. The main parameters affecting the performance of solid-phase extraction, such as sample pH and flow rate, eluent solution and volume, accumulation potential and accumulation time were investigated in detail. Under the optimum experimental conditions, a linear calibration curve was obtained in the range of 1.0 × 10(-8) to 1 × 10(-5) mol L(-1) with R(2) = 0.9979. The limit of detection (LOD) and limit of quantitation (LOQ) were 1.3 × 10(-9) and 4.3 × 10(-9) mol L(-1), respectively. The relative standard deviation (RSD) for the determination of 1.0 × 10(-6) mol L(-1) quercetin was found to be 2.9% (n = 11) along with a sampling frequency of 40 h(-1). The applicability and reliability of the automated method described here had been applied to the determination of quercetin in human urine and red wine samples through recovery experiments, and the obtained results were in good agreement with those obtained by the HPLC method.

  10. Effectiveness of leukocyte immunotherapy in primary recurrent spontaneous abortion (RSA).

    PubMed

    Gharesi-Fard, Behrouz; Zolghadri, Jaleh; Foroughinia, Leila; Tavazoo, Fahimeh; Samsami Dehaghani, Alamtaj

    2007-09-01

    Recurrent spontaneous abortion (RSA) is defined as three or more sequential abortions before the twentieth week of gestation. There are evidences to support an allo-immunologic mechanism for RSA. One of the methods for treatment of RSA is leukocyte therapy; however there is still controversy about effectiveness of this method. To evaluate the effectiveness of leukocyte therapy for treatment of RSA. Ninety two non-pregnant women with at least three sequential abortions (60 primary & 32 secondary aborters) recognized as RSA were referred to our Laboratory for immunotherapy. All the cases were immunized by isolated lymphocytes from their husbands. Fifty to 100 million washed and resuspended mononuclear cells were injected by I.V., S.C., and I.D. route. The result of each injection was checked by WBC cross matching between couples after four weeks of injections. Immunization was repeated in fifth week to a maximum of 3 times if needed. Eighty one age-matched non-pregnant RSA women (52 primary and 29 secondary aborters) with at least three sequential abortions were also included in this study as controls. The control group was not immunized. 67 out of 92 (72.8%) immunized cases and 44 out of 81 controls (54.3%) showed a successful outcome of pregnancy (p<0.02). Comparison of primary and secondary aborters indicated a significantly better outcome only in primary (75% vs. 42.3%. p<0.001) but not in secondary aborters (68.8% vs. 75.9%, p = 0.7). The present investigation showed the effectiveness of leukocyte therapy in primary but not in secondary RSA patients. Despite the current controversy and limitation of leukocyte therapy in RSA, the results of our investigation provide evidence supporting the use of allo-immunization in improving the outcome of pregnancy in primary RSA patients.

  11. Sub-1min separation in sequential injection chromatography for determination of synthetic water-soluble dyes in pharmaceutical formulation.

    PubMed

    Davletbaeva, Polina; Chocholouš, Petr; Bulatov, Andrey; Šatínský, Dalibor; Solich, Petr

    2017-09-05

    Sequential Injection Chromatography (SIC) evolved from fast and automated non-separation Sequential Injection Analysis (SIA) into chromatographic separation method for multi-element analysis. However, the speed of the measurement (sample throughput) is due to chromatography significantly reduced. In this paper, a sub-1min separation using medium polar cyano monolithic column (5mm×4.6mm) resulted in fast and green separation with sample throughput comparable with non-separation flow methods The separation of three synthetic water-soluble dyes (sunset yellow FCF, carmoisine and green S) was in a gradient elution mode (0.02% ammonium acetate, pH 6.7 - water) with flow rate of 3.0mLmin -1 corresponding with sample throughput of 30h -1 . Spectrophotometric detection wavelengths were set to 480, 516 and 630nm and 10Hz data collection rate. The performance of the separation was described and discussed (peak capacities 3.48-7.67, peak symmetries 1.72-1.84 and resolutions 1.42-1.88). The method was represented by validation parameters: LODs of 0.15-0.35mgL -1 , LOQs of 0.50-1.25mgL -1 , calibration ranges 0.50-150.00mgL -1 (r>0.998) and repeatability at 10.0mgL -1 of RSD≤0.98% (n=6). The method was used for determination of the dyes in "forest berries" colored pharmaceutical cough-cold formulation. The sample matrix - pharmaceuticals and excipients were not interfering with vis determination because of no retention in the separation column and colorless nature. The results proved the concept of fast and green chromatography approach using very short medium polar monolithic column in SIC. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Miniaturizing and automation of free acidity measurements for uranium (VI)-HNO3 solutions: Development of a new sequential injection analysis for a sustainable radio-analytical chemistry.

    PubMed

    Néri-Quiroz, José; Canto, Fabrice; Guillerme, Laurent; Couston, Laurent; Magnaldo, Alastair; Dugas, Vincent

    2016-10-01

    A miniaturized and automated approach for the determination of free acidity in solutions containing uranium (VI) is presented. The measurement technique is based on the concept of sequential injection analysis with on-line spectroscopic detection. The proposed methodology relies on the complexation and alkalimetric titration of nitric acid using a pH 5.6 sodium oxalate solution. The titration process is followed by UV/VIS detection at 650nm thanks to addition of Congo red as universal pH indicator. Mixing sequence as well as method validity was investigated by numerical simulation. This new analytical design allows fast (2.3min), reliable and accurate free acidity determination of low volume samples (10µL) containing uranium/[H(+)] moles ratio of 1:3 with relative standard deviation of <7.0% (n=11). The linearity range of the free nitric acid measurement is excellent up to 2.77molL(-1) with a correlation coefficient (R(2)) of 0.995. The method is specific, presence of actinide ions up to 0.54molL(-1) does not interfere on the determination of free nitric acid. In addition to automation, the developed sequential injection analysis method greatly improves the standard off-line oxalate complexation and alkalimetric titration method by reducing thousand fold the required sample volume, forty times the nuclear waste per analysis as well as the analysis time by eight fold. These analytical parameters are important especially in nuclear-related applications to improve laboratory safety, personnel exposure to radioactive samples and to drastically reduce environmental impacts or analytical radioactive waste. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Injection order effects on efficacy of calcium chloride and sodium tripolyphosphate in controlling the pink color defect in uncured, intact turkey breast.

    PubMed

    Claus, James R; Sawyer, Christopher A; Vogel, Kurt D

    2010-04-01

    An experiment was conducted to test sequential injection of sodium tripolyphosphate (STP; 0.5% meat weight basis, mwb) followed by injection with or without addition of calcium chloride (CaCl(2), 500 ppm mwb), and to test the effect of post-injection delay prior to cooking. A second experiment evaluated the impact of injection order and delay time between independent addition of CaCl(2) (500 ppm mwb) and STP (0.5% mwb). Turkey was formulated without an added pink generating ligand (NONE), with nicotinamide (NIC; 0.1% mwb), or with sodium nitrite (NIT; 10 ppm mwb). A white colloid was observed in the extracellular space of treatments containing both STP and CaCl(2.) Addition of CaCl(2) decreased nitrosylhemochrome but did not reduce levels of nicotinamide hemochrome or CIE a(*) values. Injection order or delay between injections did not contribute to controlling the pink defect in cooked, intact turkey breast. Published by Elsevier Ltd.

  14. Immunogenicity of simultaneous versus sequential administration of a 23-valent pneumococcal polysaccharide vaccine and a quadrivalent influenza vaccine in older individuals: A randomized, open-label, non-inferiority trial.

    PubMed

    Nakashima, Kei; Aoshima, Masahiro; Ohfuji, Satoko; Yamawaki, Satoshi; Nemoto, Masahiro; Hasegawa, Shinya; Noma, Satoshi; Misawa, Masafumi; Hosokawa, Naoto; Yaegashi, Makito; Otsuka, Yoshihito

    2018-03-21

    It is unclear whether simultaneous administration of a 23-valent pneumococcal polysaccharide vaccine (PPSV23) and a quadrivalent influenza vaccine (QIV) produces immunogenicity in older individuals. This study tested the hypothesis that the pneumococcal antibody response elicited by simultaneous administration of PPSV23 and QIV in older individuals is not inferior to that elicited by sequential administration of PPSV23 and QIV. We performed a single-center, randomized, open-label, non-inferiority trial comprising 162 adults aged ≥65 years randomly assigned to either the simultaneous (simultaneous injections of PPSV23 and QIV) or sequential (control; PPSV23 injected 2 weeks after QIV vaccination) groups. Pneumococcal immunoglobulin G (IgG) titers of serotypes 23F, 3, 4, 6B, 14, and 19A were assessed. The primary endpoint was the serotype 23F response rate (a ≥2-fold increase in IgG concentrations 4-6 weeks after PPSV23 vaccination). With the non-inferiority margin set at 20% fewer patients, the response rate of serotype 23F in the simultaneous group (77.8%) was not inferior to that of the sequential group (77.6%; difference, 0.1%; 90% confidence interval, -10.8% to 11.1%). None of the pneumococcal IgG serotype titers were significantly different between the groups 4-6 weeks after vaccination. Simultaneous administration did not show a significant decrease in seroprotection odds ratios for H1N1, H3N2, or B/Phuket influenza strains other than B/Texas. Additionally, simultaneous administration did not increase adverse reactions. Hence, simultaneous administration of PPSV23 and QIV shows an acceptable immunogenicity that is comparable to sequential administration without an increase in adverse reactions. (This study was registered with ClinicalTrials.gov [NCT02592486]).

  15. Visual detection and sequential injection determination of aluminium using a cinnamoyl derivative.

    PubMed

    Elečková, Lenka; Alexovič, Michal; Kuchár, Juraj; Balogh, Ioseph S; Andruch, Vasil

    2015-02-01

    A cinnamoyl derivative, 3-[4-(dimethylamino)cinnamoyl]-4-hydroxy-6-methyl-3,4-2H-pyran-2-one, was used as a ligand for the determination of aluminium. Upon the addition of an acetonitrile solution of the ligand to an aqueous solution containing Al(III) and a buffer solution at pH 8, a marked change in colour from yellow to orange is observed. The colour intensity is proportional to the concentration of Al(III); thus, the 'naked-eye' detection of aluminium is possible. The reaction is also applied for sequential injection determination of aluminium. Beer׳s law is obeyed in the range from 0.055 to 0.66 mg L(-1) of Al(III). The limit of detection, calculated as three times the standard deviation of the blank test (n=10), was found to be 4 μg L(-1) for Al(III). The method was applied for the determination of aluminium in spiked water samples and pharmaceutical preparations. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Monitoring variations of dimethyl sulfide and dimethylsulfoniopropionate in seawater and the atmosphere based on sequential vapor generation and ion molecule reaction mass spectrometry.

    PubMed

    Iyadomi, Satoshi; Ezoe, Kentaro; Ohira, Shin-Ichi; Toda, Kei

    2016-04-01

    To monitor the fluctuations of dimethyl sulfur compounds at the seawater/atmosphere interface, an automated system was developed based on sequential injection analysis coupled with vapor generation-ion molecule reaction mass spectrometry (SIA-VG-IMRMS). Using this analytical system, dissolved dimethyl sulfide (DMS(aq)) and dimethylsulfoniopropionate (DMSP), a precursor to DMS in seawater, were monitored together sequentially with atmospheric dimethyl sulfide (DMS(g)). A shift from the equilibrium point between DMS(aq) and DMS(g) results in the emission of DMS to the atmosphere. Atmospheric DMS emitted from seawater plays an important role as a source of cloud condensation nuclei, which influences the oceanic climate. Water samples were taken periodically and dissolved DMS(aq) was vaporized for analysis by IMRMS. After that, DMSP was hydrolyzed to DMS and acrylic acid, and analyzed in the same manner as DMS(aq). The vaporization behavior and hydrolysis of DMSP to DMS were investigated to optimize these conditions. Frequent (every 30 min) determination of the three components, DMS(aq)/DMSP (nanomolar) and DMS(g) (ppbv), was carried out by SIA-VG-IMRMS. Field analysis of the dimethyl sulfur compounds was undertaken at a coastal station, which succeeded in showing detailed variations of the compounds in a natural setting. Observed concentrations of the dimethyl sulfur compounds both in the atmosphere and seawater largely changed with time and similar variations were repeatedly observed over several days, suggesting diurnal variations in the DMS flux at the seawater/atmosphere interface.

  17. Use of Protein G Microcolumns in Chromatographic Immunoassays: A Comparison of Competitive Binding Formats

    PubMed Central

    Pfaunmiller, Erika L.; Anguizola, Jeanethe A.; Milanuk, Mitchell L.; Carter, NaTasha; Hage, David S.

    2016-01-01

    Affinity microcolumns containing protein G were used as general platforms for creating chromatographic-based competitive binding immunoassays. Human serum albumin (HSA) was used as a model target for this work and HSA tagged with a near infrared fluorescent dye was utilized as the label. The protein G microcolumns were evaluated for use in several assay formats, including both solution-based and column-based competitive binding immunoassays and simultaneous or sequential injection formats. All of these methods were characterized by using the same amounts of labeled HSA and anti-HSA antibodies per sample, as chosen for the analysis of a protein target in the low-to-mid ng/mL range. The results were used to compare these formats in terms of their response, precision, limits of detection, and analysis time. All these methods gave detection limits in the range of 8–19 ng/mL and precisions ranging from ± 5% to ± 10% when using an injection flow rate of 0.10 mL/min. The column-based sequential injection immunoassay provided the best limit of detection and the greatest change in response at low target concentrations, while the solution-based simultaneous injection method had the broadest linear and dynamic ranges. These results provided valuable guidelines that can be employed to develop and extend the use of protein G microcolumns and these competitive binding formats to other protein biomarkers or biological agents of clinical or pharmaceutical interest. PMID:26777776

  18. A weight modification sequential method for VSC-MTDC power system state estimation

    NASA Astrophysics Data System (ADS)

    Yang, Xiaonan; Zhang, Hao; Li, Qiang; Guo, Ziming; Zhao, Kun; Li, Xinpeng; Han, Feng

    2017-06-01

    This paper presents an effective sequential approach based on weight modification for VSC-MTDC power system state estimation, called weight modification sequential method. The proposed approach simplifies the AC/DC system state estimation algorithm through modifying the weight of state quantity to keep the matrix dimension constant. The weight modification sequential method can also make the VSC-MTDC system state estimation calculation results more ccurate and increase the speed of calculation. The effectiveness of the proposed weight modification sequential method is demonstrated and validated in modified IEEE 14 bus system.

  19. Selective sequential precipitation of dissolved metals in mine drainage from coal mine

    NASA Astrophysics Data System (ADS)

    Yim, Giljae; Bok, Songmin; Ji, Sangwoo; Oh, Chamteut; Cheong, Youngwook; Han, Youngsoo; Ahn, Joosung

    2017-04-01

    In abandoned mines in Korea, a large amount of mine drainage continues to flow out and spread pollution. In purification of the mine drainage a massive amount of sludge is generated as waste. Since this metal sludge contains high Fe, Al and Mn oxides, developing the treatment method to recover homogeneous individual metal with high purity may beneficial to recycle waste metals as useful resources and reduce the amount of sludge production. In this regard, we established a dissolved metals selective precipitation process to treat Waryong Industry's mine drainage. The process that selectively precipitates metals dissolved in mine drainage is a continuous Fe-buffer-Al process, and each process consists of the neutralization tank, the coagulation tank, and the settling tank. Based on this process, this study verified the operational applicability of the Fe and Al selective precipitation. Our previous study revealed that high-purity Fe and Al precipitates could be recovered at a flow rate of 1.5 ton/day, while the lower purity was achieved when the rate was increased to about 3 ton/day due to the difficulty in reagent dosage control. In the current study was conducted to increase the capacity of the system to recover Fe and Al as high-purity precipitates at a flow rate of 10 ton/day with the ensured continuous operations by introducing an automatic reagent injection system. The previous study had a difficulty in controlling the pH and operating system continuously due to the manually controlled reagent injection system. To upgrade this and ensure the optimal pH in a stable way, a continuous reagent injection system was installed. The result of operation of the 10 ton/day system confirmed that the scaled-up process could maintain the stable recovery rates and purities of precipitates on site.

  20. Vaccine allergy and pseudo-allergy.

    PubMed

    Ponvert, Claude; Scheinmann, Pierre

    2003-01-01

    Allergic and pseudo-allergic reactions to vaccines frequently involve the skin, and can be generalized systemic symptoms (urticaria/angioedema, serum sickness, flares of eczema) or localized at the sites of vaccination (persistent nodules, abcesses, granulomas). Diagnosis of Arthus-type reactions is based on clinical history and specific IgM/IgG anti-toxoid determination. For other local reactions, diagnostic value of non-immediate responses in skin tests varies with clinical symptoms and substances involved. Immediate responses in skin tests and specific IgE determination have good diagnostic and/or predictive value in anaphylaxis and immediate/accelerated urticaria/angioedema to toxoid-, pneumococcus-, and egg- and gelatin-containing vaccines. Diagnosis of reactions to dextran in BCG is based on specific IgM/IgG determination. Most non-immediate generalized reactions result from non-specific inflammation, except for gelatin-containing vaccines, but the diagnostic value of immuno-allergological tests with the vaccines and gelatin are controversial. Withholding booster injections is advised if specific IgM/IgG levels are high. If the levels are low, sequential injections of vaccines containing a single vaccinating agent are usually tolerated. However, injections of the vaccine should be performed using a " desensitization " procedure in patients reporting anaphylaxis and immediate/accelerated urticaria/angioedema.

  1. Investigation of arsenic removal in batch wise water treatments by means of sequential hydride generation flow injection analysis.

    PubMed

    Toda, Kei; Takaki, Mari; Hashem, Md Abul

    2008-08-01

    Arsenic water pollution is a big issue worldwide. Determination of inorganic arsenic in each oxidation state is important because As(III) is much more toxic than As(V). An automated arsenic measurement system was developed based on complete vaporization of As by a sequential procedure and collection/preconcentration of the vaporized AsH(3), which was subsequently measured by a flow analysis. The automated sensitive method was applied to monitoring As(III) and As(V) concentrations in contaminated water standing overnight. Behaviors of arsenics were investigated in different conditions, and unique time dependence profiles were obtained. For example, in the standing of anaerobic water samples, the As(III) concentration immediately began decreasing whereas dead time was observed in the removal of As(V). In normal groundwater conditions, most arsenic was removed from the water simply by standing overnight. To obtain more effective removal, the addition of oxidants and use of steel wools were investigated. Simple batch wise treatments of arsenic contaminated water were demonstrated, and detail of the transitional changes in As(III) and As(V) were investigated.

  2. The duration of hyaluronidase and optimal timing of hyaluronic acid (HA) filler reinjection after hyaluronidase injection.

    PubMed

    Kim, H J; Kwon, S B; Whang, K U; Lee, J S; Park, Y L; Lee, S Y

    2018-02-01

    Hyaluronidase injection is a commonly performed treatment for overcorrection or misplacement of hyaluronic acid (HA) filler. Many patients often wants the HA filler reinjection after the use of hyaluronidase, though the optimal timing of reinjection of HA filler still remains unknown. To provide the optimal time interval between hyaluronidase injections and HA filler reinjections. 6 Sprague-Dawley rats were injected with single monophasic HA filler. 1 week after injection, the injected sites were treated with hyaluronidase. Then, HA fillers were reinjected sequentially with differing time intervals from 30 minutes to 14 days. 1 hour after the reinjection of the last HA filler, all injection sites were excised for histologic evaluation. 3 hours after reinjection of HA filler, the appearance of filler material became evident again, retaining its shape and volume. 6 hours after reinjection, the filler materials restored almost its original volume and there were no significant differences from the positive control. Our data suggest that the hyaluronidase loses its effect in dermis and subcutaneous tissue within 3-6 hours after the injection and successful engraftment of reinjected HA filler can be accomplished 6 hours after the injection.

  3. Method development for the determination of arsenic by sequential injection/anodic stripping voltammetry using long-lasting gold-modified screen-printed carbon electrode.

    PubMed

    Punrat, Eakkasit; Chuanuwatanakul, Suchada; Kaneta, Takashi; Motomizu, Shoji; Chailapakul, Orawon

    2013-11-15

    An automated method has been developed for determining the concentration of inorganic arsenic. The technique uses sequential injection/anodic stripping voltammetry with a long-lasting gold-modified screen-printed carbon electrode. The long-lasting gold electrode was electrochemically deposited onto a screen-printed carbon electrode at a potential of -0.5 V vs. Ag/AgCl in a supporting electrolyte solution of 1M hydrochloric acid. Under optimal conditions and the applied potentials, the electrode demonstrated that it can be used for a long time without a renewal process. The linear range for the determination of arsenic(III) was 1-100 μg L(-1), and the limit of detection (LOD) in standard solutions was as low as 0.03 μg L(-1) for a deposition time of 120 s and sample volume of 1 mL. This method was used to determine the concentration of arsenic(III) in water samples with satisfactory results. The LOD in real samples was found to be 0.5 μg L(-1). In addition, speciation between arsenic(III) and arsenic(V) has been achieved with the proposed method using deposition potentials of -0.5 V and -1.5 V for the determination of the arsenic(III) concentration and the total arsenic concentration, respectively; the results were acceptable. The proposed method is an automated system that offers a less expensive alternative for determining trace amounts of inorganic arsenic. © 2013 Elsevier B.V. All rights reserved.

  4. Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype.

    PubMed

    Herbst, Daniel P

    2014-09-01

    Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient's systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26-33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique.

  5. Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype

    PubMed Central

    Herbst, Daniel P.

    2014-01-01

    Abstract: Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient’s systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26–33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique. PMID:26357790

  6. Expanding Lipidome Coverage Using LC-MS/MS Data-Dependent Acquisition with Automated Exclusion List Generation

    NASA Astrophysics Data System (ADS)

    Koelmel, Jeremy P.; Kroeger, Nicholas M.; Gill, Emily L.; Ulmer, Candice Z.; Bowden, John A.; Patterson, Rainey E.; Yost, Richard A.; Garrett, Timothy J.

    2017-05-01

    Untargeted omics analyses aim to comprehensively characterize biomolecules within a biological system. Changes in the presence or quantity of these biomolecules can indicate important biological perturbations, such as those caused by disease. With current technological advancements, the entire genome can now be sequenced; however, in the burgeoning fields of lipidomics, only a subset of lipids can be identified. The recent emergence of high resolution tandem mass spectrometry (HR-MS/MS), in combination with ultra-high performance liquid chromatography, has resulted in an increased coverage of the lipidome. Nevertheless, identifications from MS/MS are generally limited by the number of precursors that can be selected for fragmentation during chromatographic elution. Therefore, we developed the software IE-Omics to automate iterative exclusion (IE), where selected precursors using data-dependent topN analyses are excluded in sequential injections. In each sequential injection, unique precursors are fragmented until HR-MS/MS spectra of all ions above a user-defined intensity threshold are acquired. IE-Omics was applied to lipidomic analyses in Red Cross plasma and substantia nigra tissue. Coverage of the lipidome was drastically improved using IE. When applying IE-Omics to Red Cross plasma and substantia nigra lipid extracts in positive ion mode, 69% and 40% more molecular identifications were obtained, respectively. In addition, applying IE-Omics to a lipidomics workflow increased the coverage of trace species, including odd-chained and short-chained diacylglycerides and oxidized lipid species. By increasing the coverage of the lipidome, applying IE to a lipidomics workflow increases the probability of finding biomarkers and provides additional information for determining etiology of disease.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morishita, Sadaharu; Goto, Tetsuya; Nagase, Masaaki

    Multiprocesses in a single plasma process chamber with high throughput require precise, sequential, high-speed alteration of partial pressures of multiple gas species. A conventional gas-distribution system cannot realize this because the system seriously overshoots gas pressure immediately following valve operation. Furthermore, chamber volume and conductance of gas piping between the system and chamber should both be considered because they delay the stabilizing time of gas pressure. Therefore, the authors proposed a new gas-distribution system without overshoot by controlling gas flow rate based on pressure measurement, as well as a method of pulse-controlled gas injection immediately following valve operation. Time variationmore » of measured partial pressure agrees well with a calculation based on an equivalent-circuit model that represents the chamber and gas piping between the system and chamber. Using pulse-controlled gas injection, the stabilizing time can be reduced drastically to 0.6 s for HBr added to pure Ar plasma, and 0.7 s for O{sub 2} added to Ar/HBr plasma; without the pulse control, the stabilizing times are 3 and 7 s, respectively. In the O{sub 2} addition case, rapid stabilization can be achieved during the period of line/space pattern etching of poly-Si on a thin SiO{sub 2} film. This occurs without anomalous etching of the underlying SiO{sub 2} film or the Si substrate near the sidewall, thus obtaining a wide process margin with high throughput.« less

  8. pH-based fiber optic biosensors for use in clinical and biotechnological applications

    NASA Astrophysics Data System (ADS)

    Mueller, Cord; Hitzmann, Bernd; Schubert, Florian; Scheper, Thomas

    1995-05-01

    The development of pH-based fiber optic biosensors and their uses in clinical and biotechnological applications are described. Based on a pH-sensitive optode, different biosensors for urea, penicillin, glucose and creatinine were developed. A multichannel modular fluorimeter was used to measure signals from up to three optodes simultaneously. The pH value and the buffer capacity are critical factors for biosensors based on pH probes and influence the biosensor signal. A flow injection analysis (FIA) system is used to eliminate the latter influences. With this integrated system, samples can be analyzed sequentially by the injection of a defined volume of each sample into a continuously flowing buffer stream that transports the samples to the sensors. The complex signal is transformed and analyzed by a computer system. Characteristic features of the FIA peak give information about the buffer capacity in the solution. With the help of intelligent computing (neural networks) it is possible to recognize these features and relate them to the respective buffer capacity to obtain more accurate values. Various applications of these biosensors are discussed. The pH optode is also used to monitor enzymatic reactions in non aqueous solvents. In this case the production of acetic acid can be detected on line.

  9. Advantages of core-shell particle columns in Sequential Injection Chromatography for determination of phenolic acids.

    PubMed

    Chocholouš, Petr; Vacková, Jana; Srámková, Ivana; Satínský, Dalibor; Solich, Petr

    2013-01-15

    Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1) (r>0.997) and a system precision of 10 mg L(-1) with a RSD ≤ 1.65%. The high performance of the chromatography process with the RP-Amide column under optimised conditions was highlighted and well documented (HETP values ≤ 10 μm, peak symmetry ≤ 1.33, resolution ≥ 1.87 and time for one analysis <8.0 min). The results of these experiments confirmed the benefits of extending chromatographic selectivity using core-shell particle column technology in a SIC manifold. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. 9 CFR 113.43 - Detection of chlamydial agents.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... in a filed Outline of Production. (a) The yolk sac of 6-day-old chicken embryos shall be injected. Three groups of 10 embryos shall be used sequentially. (1) The inoculum for each embryo in the first... embryos shall be harvested, pooled, homogenized as a 20 percent suspension in phosphate buffered saline...

  11. 9 CFR 113.43 - Detection of chlamydial agents.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... in a filed Outline of Production. (a) The yolk sac of 6-day-old chicken embryos shall be injected. Three groups of 10 embryos shall be used sequentially. (1) The inoculum for each embryo in the first... embryos shall be harvested, pooled, homogenized as a 20 percent suspension in phosphate buffered saline...

  12. 9 CFR 113.43 - Detection of chlamydial agents.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... in a filed Outline of Production. (a) The yolk sac of 6-day-old chicken embryos shall be injected. Three groups of 10 embryos shall be used sequentially. (1) The inoculum for each embryo in the first... embryos shall be harvested, pooled, homogenized as a 20 percent suspension in phosphate buffered saline...

  13. 9 CFR 113.43 - Detection of chlamydial agents.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... in a filed Outline of Production. (a) The yolk sac of 6-day-old chicken embryos shall be injected. Three groups of 10 embryos shall be used sequentially. (1) The inoculum for each embryo in the first... embryos shall be harvested, pooled, homogenized as a 20 percent suspension in phosphate buffered saline...

  14. Deferiprone, a non-toxic reagent for determination of iron in samples via sequential injection analysis

    NASA Astrophysics Data System (ADS)

    Pragourpun, Kraivinee; Sakee, Uthai; Fernandez, Carlos; Kruanetr, Senee

    2015-05-01

    We present for the first time the use of deferiprone as a non-toxic complexing agent for the determination of iron by sequential injection analysis in pharmaceuticals and food samples. The method was based on the reaction of Fe(III) and deferiprone in phosphate buffer at pH 7.5 to give a Fe(III)-deferiprone complex, which showed a maximum absorption at 460 nm. Under the optimum conditions, the linearity range for iron determination was found over the range of 0.05-3.0 μg mL-1 with a correlation coefficient (r2) of 0.9993. The limit of detection and limit of quantitation were 0.032 μg mL-1 and 0.055 μg mL-1, respectively. The relative standard deviation (%RSD) of the method was less than 5.0% (n = 11), and the percentage recovery was found in the range of 96.0-104.0%. The proposed method was satisfactorily applied for the determination of Fe(III) in pharmaceuticals, water and food samples with a sampling rate of 60 h-1.

  15. Sequential PLD in oxygen/argon gas mixture of Al-doped ZnO thin films with improved electrical and optical properties

    NASA Astrophysics Data System (ADS)

    Coman, Tudor; Timpu, Daniel; Nica, Valentin; Vitelaru, Catalin; Rambu, Alicia Petronela; Stoian, George; Olaru, Mihaela; Ursu, Cristian

    2017-10-01

    Highly conductive transparent Al-doped ZnO (AZO) thin films were obtained at room temperature through sequential PLD (SPLD) from Zn and Al metallic targets in an oxygen/argon gas mixture. We have investigated the structural, electrical and optical properties as a function of the oxygen/argon pressure ratio in the chamber. The measured Hall carrier concentration was found to increase with argon injection from 1.3 × 1020 to 6.7 × 1020 cm-3, while the laser shots ratio for Al/Zn targets ablation was kept constant. This increase was attributed to an enhancement of the substitution doping into the ZnO lattice. The argon injection also leads to an increase of the Hall mobility up to 20 cm2 V-1 s-1, attributed to a reduction of interstitial-type defects. Thus, the approach of using an oxygen/argon gas mixture during SPLD from metallic targets allows obtaining at room temperature AZO samples with high optical transmittance (about 90%) and low electrical resistivity (down to 5.1 × 10-4 Ω cm).

  16. High-performance serial block-face SEM of nonconductive biological samples enabled by focal gas injection-based charge compensation.

    PubMed

    Deerinck, T J; Shone, T M; Bushong, E A; Ramachandra, R; Peltier, S T; Ellisman, M H

    2018-05-01

    A longstanding limitation of imaging with serial block-face scanning electron microscopy is specimen surface charging. This charging is largely due to the difficulties in making biological specimens and the resins in which they are embedded sufficiently conductive. Local accumulation of charge on the specimen surface can result in poor image quality and distortions. Even minor charging can lead to misalignments between sequential images of the block-face due to image jitter. Typically, variable-pressure SEM is used to reduce specimen charging, but this results in a significant reduction to spatial resolution, signal-to-noise ratio and overall image quality. Here we show the development and application of a simple system that effectively mitigates specimen charging by using focal gas injection of nitrogen over the sample block-face during imaging. A standard gas injection valve is paired with a precisely positioned but retractable application nozzle, which is mechanically coupled to the reciprocating action of the serial block-face ultramicrotome. This system enables the application of nitrogen gas precisely over the block-face during imaging while allowing the specimen chamber to be maintained under high vacuum to maximise achievable SEM image resolution. The action of the ultramicrotome drives the nozzle retraction, automatically moving it away from the specimen area during the cutting cycle of the knife. The device described was added to a Gatan 3View system with minimal modifications, allowing high-resolution block-face imaging of even the most charge prone of epoxy-embedded biological samples. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  17. Simple systems for treating pumped, turbid water with flocculants and a geotextile dewatering bag.

    PubMed

    Kang, Jihoon; McLaughlin, Richard A

    2016-11-01

    Pumping sediment-laden water from excavations is often necessary on construction sites. This water is often treated by pumping it through geotextile dewatering bags. The bags are not designed to filter the fine sediments that create high turbidity, but dosing with a flocculant prior to the bag could result in greater turbidity control. This study compared two systems for introducing flocculant: passive dosing of commercial solid biopolymer (chitosan) and injection of dissolved polyacrylamide (PAM) in a length of corrugated pipe connected to the bag. The biopolymer system consisted of sequential porous socks containing a "charging agent" followed by chitosan in the corrugated pipe with two levels of dosing. The dissolved PAM was injected into turbid water at a flow-weighted concentration at 1 mg L(-1). For each treatment, sediment-laden turbid water in the range of 2000 to 3500 nephelometric turbidity units (NTU) was pumped into the upstream of corrugated pipe and samples were taken from pipe entrance, pipe exit, and dewatering bag exit. Without flocculant treatment, the dewatering bag reduced turbidity by 70% but the addition of flocculant increased the turbidity reduction up to 97% relative to influent. At the pipe exit, the low-dose biopolymer was less effective in reducing turbidity (37%) but it was equally effective as the high-dose biopolymer or PAM injection after the bag. Our results suggest that a relatively simple treatment with flocculants, either passively or actively, can be very effective in reducing turbidity for pumped water on construction sites. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Injectable 3-D Fabrication of Medical Electronics at the Target Biological Tissues

    NASA Astrophysics Data System (ADS)

    Jin, Chao; Zhang, Jie; Li, Xiaokang; Yang, Xueyao; Li, Jingjing; Liu, Jing

    2013-12-01

    Conventional transplantable biomedical devices generally request sophisticated surgery which however often causes big trauma and serious pain to the patients. Here, we show an alternative way of directly making three-dimensional (3-D) medical electronics inside the biological body through sequential injections of biocompatible packaging material and liquid metal ink. As the most typical electronics, a variety of medical electrodes with different embedded structures were demonstrated to be easily formed at the target tissues. Conceptual in vitro experiments provide strong evidences for the excellent performances of the injectable electrodes. Further in vivo animal experiments disclosed that the formed electrode could serve as both highly efficient ECG (Electrocardiograph) electrode and stimulator electrode. These findings clarified the unique features and practicability of the liquid metal based injectable 3-D fabrication of medical electronics. The present strategy opens the way for directly manufacturing electrophysiological sensors or therapeutic devices in situ via a truly minimally invasive approach.

  19. Attenuation-difference radar tomography: results of a multiple-plane experiment at the U.S. Geological Survey Fractured-Rock Research Site, Mirror Lake, New Hampshire

    USGS Publications Warehouse

    Lane, J.W.; Day-Lewis, F. D.; Harris, J.M.; Haeni, F.P.; Gorelick, S.M.

    2000-01-01

    Attenuation-difference, borehole-radar tomography was used to monitor a series of sodium chloride tracer injection tests conducted within the FSE, wellfield at the U.S. Geological Survey Fractured-Rock Hydrology Research Site in Grafton County, New Hampshire, USA. Borehole-radar tomography surveys were conducted using the sequential-scanning and injection method in three boreholes that form a triangular prism of adjoining tomographic image planes. Results indicate that time-lapse tomography methods provide high-resolution images of tracer distribution in permeable zones.

  20. Treatment of menopausal symptoms with three low-dose continuous sequential 17β-estradiol/progesterone parenteral monthly formulations using novel non-polymeric microsphere technology

    PubMed Central

    Cortés-Bonilla, Manuel; Bernardo-Escudero, Roberto; Alonso-Campero, Rosalba; Francisco-Doce, María T.; Hernández-Valencia, Marcelino; Celis-González, Cuauhtémoc; Márquez-Oñate, Ricardo; Chedraui, Peter; Uribe, Juan A.

    2015-01-01

    Abstract Objective: To analyze the short-term efficacy and safety over menopausal symptoms of three low-dose continuous sequential 17β-estradiol (E)/progesterone (P) parental monthly formulations using novel non-polymeric microspheres. Methods: This was a multicenter, randomized, single blinded study in which peri- and postmenopausal women were assigned to receive a monthly intramuscular injection of 0.5 mg E + 15 mg P (Group A, n = 34), 1 mg E + 20 mg P (Group B, n = 24) or 1 mg E + 30 mg P (Group C, n = 26) for 6 months. Primary efficacy endpoints included mean change in the frequency and severity of hot flushes and the effect over urogenital atrophy symptoms at 3 and 6 months. Safety variables included changes in the rate of amenorrhea, endometrial thickness and histopathology, and local and systemic adverse events. Results: Compared to baseline at month 6, the three treatment schemes significantly decreased the rate of urogenital atrophy symptoms and the frequency (mean number per day) and severity (mean number graded as moderate and severe per month) of hot flushes. No differences in studied efficacy parameters were observed between studied groups at baseline or at the end of the study. For all groups the most frequent adverse event was pain at the injection site; however they were all rated as mild. At the end of the study peri- and postmenopausal women displayed no significant changes in endometrial thickness or histopathology in all treated groups. The rate of amenorrhea at the end of the study decreased for all studied groups yet was less evident among postmenopausal women as compared to perimenopausal ones. Conclusions: The three low-dose continuous sequential intramuscular monthly treatments of E/P using novel microsphere technology were effective at reducing menopausal symptoms at short-term with a low rate of adverse events. More long-term and comparative research is warranted to support our positive findings. PMID:26062108

  1. Intra-tumor distribution of PEGylated liposome upon repeated injection: No possession by prior dose.

    PubMed

    Nakamura, Hiroyuki; Abu Lila, Amr S; Nishio, Miho; Tanaka, Masao; Ando, Hidenori; Kiwada, Hiroshi; Ishida, Tatsuhiro

    2015-12-28

    Liposomes have proven to be a viable means for the delivery of chemotherapeutic agents to solid tumors. However, significant variability has been detected in their intra-tumor accumulation and distribution, resulting in compromised therapeutic outcomes. We recently examined the intra-tumor accumulation and distribution of weekly sequentially administered oxaliplatin (l-OHP)-containing PEGylated liposomes. In that study, the first and second doses of l-OHP-containing PEGylated liposomes were distributed diversely and broadly within tumor tissues, resulting in a potent anti-tumor efficacy. However, little is known about the mechanism underlying such a diverse and broad liposome distribution. Therefore, in the present study, we investigated the influence of dosage interval on the intra-tumor accumulation and distribution of "empty" PEGylated liposomes. Intra-tumor distribution of sequentially administered "empty" PEGylated liposomes was altered in a dosing interval-dependent manner. In addition, the intra-tumor distribution pattern was closely related to the chronological alteration of tumor blood flow as well as vascular permeability in the growing tumor tissue. These results suggest that the sequential administrations of PEGylated liposomes in well-spaced intervals might allow the distribution to different areas and enhance the total bulk accumulation within tumor tissue, resulting in better therapeutic efficacy of the encapsulated payload. This study may provide useful information for a better design of therapeutic regimens involving multiple administrations of nanocarrier drug delivery systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Phantom auditory sensation in rats: an animal model for tinnitus.

    PubMed

    Jastreboff, P J; Brennan, J F; Coleman, J K; Sasaki, C T

    1988-12-01

    In order to measure tinnitus induced by sodium salicylate injections, 84 pigmented rats, distributed among 14 groups in five experiments, were used in a conditioned suppression paradigm. In Experiment 1, all groups were trained with a conditioned stimulus (CS) consisting of the offset of a continuous background noise. One group began salicylate injections before Pavlovian training, a second group started injections after training, and a control group received daily saline injections. Resistance to extinction was profound when injections started before training, but minimal when initiated after training, which suggests that salicylate-induced effects acquired differential conditioned value. In Experiment 2 we mimicked the salicylate treatments by substituting a 7 kHz tone in place of respective injections, resulting in effects equivalent to salicylate-induced behavior. In a third experiment we included a 3 kHz CS, and again replicated the salicylate findings. In Experiment 4 we decreased the motivational level, and the sequential relation between salicylate-induced effects and suppression training was retained. Finally, no salicylate effects emerged when the visual modality was used. These findings support the demonstration of phantom auditory sensations in animals.

  3. Effects of neostriatal 6-OHDA lesion on performance in a rat sequential reaction time task.

    PubMed

    Domenger, D; Schwarting, R K W

    2008-10-31

    Work in humans and monkeys has provided evidence that the basal ganglia, and the neurotransmitter dopamine therein, play an important role for sequential learning and performance. Compared to primates, experimental work in rodents is rather sparse, largely due to the fact that tasks comparable to the human ones, especially serial reaction time tasks (SRTT), had been lacking until recently. We have developed a rat model of the SRTT, which allows to study neural correlates of sequential performance and motor sequence execution. Here, we report the effects of dopaminergic neostriatal lesions, performed using bilateral 6-hydroxydopamine injections, on performance of well-trained rats tested in our SRTT. Sequential behavior was measured in two ways: for one, the effects of small violations of otherwise well trained sequences were examined as a measure of attention and automation. Secondly, sequential versus random performance was compared as a measure of sequential learning. Neurochemically, the lesions led to sub-total dopamine depletions in the neostriatum, which ranged around 60% in the lateral, and around 40% in the medial neostriatum. These lesions led to a general instrumental impairment in terms of reduced speed (response latencies) and response rate, and these deficits were correlated with the degree of striatal dopamine loss. Furthermore, the violation test indicated that the lesion group conducted less automated responses. The comparison of random versus sequential responding showed that the lesion group did not retain its superior sequential performance in terms of speed, whereas they did in terms of accuracy. Also, rats with lesions did not improve further in overall performance as compared to pre-lesion values, whereas controls did. These results support previous results that neostriatal dopamine is involved in instrumental behaviour in general. Also, these lesions are not sufficient to completely abolish sequential performance, at least when acquired before lesion as tested here.

  4. An Interactive Excel Program for Tracking a Single Droplet in Crossflow Computation

    NASA Technical Reports Server (NTRS)

    Urip, E.; Yang, S. L.; Marek, C. J.

    2002-01-01

    Spray jet in crossflow has been a subject of research because of its wide application in systems involving pollutant dispersion, jet mixing in the dilution zone of combustors, and fuel injection strategies. The focus of this work is to investigate dispersion of a 2-dimensional atomized spray jet into a 2-dimensional crossflow. A quick computational method is developed using available software. The spreadsheet can be used for any 2D droplet trajectory problem where the drop is injected into the free stream eventually coming to the free stream conditions. During the transverse injection of a spray into high velocity airflow, the droplets (carried along and deflected by a gaseous stream of co-flowing air) are subjected to forces that affect their motion in the flow field. Based on the Newton's Second Law of motion, four ordinary differential equations were used. These equations were then solved by a fourth-order Runge-Kutta method using Excel software. Visual basic programming and Excel macrocode to produce the data facilitate Excel software to plot graphs describing the droplet's motion in the flow field. This program computes and plots the data sequentially without forcing users to open other types of plotting programs. A user's manual on how to use the program is also included in this report.

  5. Effect of nicergoline on cerebral blood flow

    PubMed Central

    Iliff, L. D.; Boulay, G. H. Du; Marshall, John; Russell, R. W. Ross; Symon, Lindsay

    1977-01-01

    Cerebral blood flow (CBF) was measured before and after intravenous injection of the cerebral vasodilator nicergoline in 13 patients with cerebrovascular disease. CBF increased in seven. The possibility that the effect of the drug in the remainder may have been masked by a fall of CBF which occurs during sequential measurement of patients at rest is discussed. PMID:925694

  6. Identification of inorganic improvised explosive devices using sequential injection capillary electrophoresis and contactless conductivity detection.

    PubMed

    Blanco, Gustavo A; Nai, Yi H; Hilder, Emily F; Shellie, Robert A; Dicinoski, Greg W; Haddad, Paul R; Breadmore, Michael C

    2011-12-01

    A simple sequential injection capillary electrophoresis (SI-CE) instrument with capacitively coupled contactless conductivity detection (C(4)D) has been developed for the rapid separation of anions relevant to the identification of inorganic improvised explosive devices (IEDs). Four of the most common explosive tracer ions, nitrate, perchlorate, chlorate, and azide, and the most common background ions, chloride, sulfate, thiocyanate, fluoride, phosphate, and carbonate, were chosen for investigation. Using a separation electrolyte comprising 50 mM tris(hydroxymethyl)aminomethane, 50 mM cyclohexyl-2-aminoethanesulfonic acid, pH 8.9 and 0.05% poly(ethyleneimine) (PEI) in a hexadimethrine bromide (HDMB)-coated capillary it was possible to partially separate all 10 ions within 90 s. The combination of two cationic polymer additives (PEI and HDMB) was necessary to achieve adequate selectivity with a sufficiently stable electroosmotic flow (EOF), which was not possible with only one polymer. Careful optimization of variables affecting the speed of separation and injection timing allowed a further reduction of separation time to 55 s while maintaining adequate efficiency and resolution. Software control makes high sample throughput possible (60 samples/h), with very high repeatability of migration times [0.63-2.07% relative standard deviation (RSD) for 240 injections]. The separation speed does not compromise sensitivity, with limits of detection ranging from 23 to 50 μg·L(-1) for all the explosive residues considered, which is 10× lower than those achieved by indirect absorbance detection and 2× lower than those achieved by C(4)D using portable benchtop instrumentation. The combination of automation, high sample throughput, high confidence of peak identification, and low limits of detection makes this methodology ideal for the rapid identification of inorganic IED residues.

  7. Determination of essential elements in beverages, herbal infusions and dietary supplements using a new straightforward sequential approach based on flame atomic absorption spectrometry.

    PubMed

    Gómez-Nieto, Beatriz; Gismera, Mª Jesús; Sevilla, Mª Teresa; Procopio, Jesús R

    2017-03-15

    A simple method based on FAAS was developed for the sequential multi-element determination of Cu, Zn, Mn, Mg and Si in beverages and food supplements with successful results. The main absorption lines for Cu, Zn and Si and secondary lines for Mn and Mg were selected to carry out the measurements. The sample introduction was performed using a flow injection system. Using the choice of the absorption line wings, the upper limit of the linear range increased up to 110mgL -1 for Mg, 200mgL -1 for Si and 13mgL -1 for Zn. The determination of the five elements was carried out, in triplicate, without the need of additional sample dilutions and/or re-measurements, using less than 3.5mL of sample to perform the complete analysis. The LODs were 0.008mgL -1 for Cu, 0.017mgL -1 for Zn, 0.011mgL -1 for Mn, 0.16mgL -1 for Si and 0.11mgL -1 for Mg. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Mathematical modeling heat and mass transfer processes in porous media

    NASA Astrophysics Data System (ADS)

    Akhmed-Zaki, Darkhan

    2013-11-01

    On late development stages of oil-fields appears a complex problem of oil-recovery reduction. One of solution approaches is injecting of surfactant together with water in the form of active impurities into the productive layer - for decreasing oil viscosity and capillary forces between ``oil-water'' phases system. In fluids flow the surfactant can be in three states: dissolved in water, dissolved in oil and adsorbed on pore channels' walls. The surfactant's invasion into the reservoir is tracked by its diffusion with reservoir liquid and mass-exchange with two phase (liquid and solid) components of porous structure. Additionally, in this case heat exchange between fluids (injected, residual) and framework of porous medium has practical importance for evaluating of temperature influences on enhancing oil recovery. Now, the problem of designing an adequate mathematical model for describing a simultaneous flowing heat and mass transfer processes in anisotropic heterogeneous porous medium -surfactant injection during at various temperature regimes has not been fully researched. In this work is presents a 2D mathematical model of surfactant injections into the oil reservoir. Description of heat- and mass transfer processes in a porous media is done through differential and kinetic equations. For designing a computational algorithm is used modify version of IMPES method. The sequential and parallel computational algorithms are developed using an adaptive curvilinear meshes which into account heterogeneous porous structures. In this case we can evaluate the boundaries of our process flows - fronts (``invasion'', ``heat'' and ``mass'' transfers), according to the pressure, temperature, and concentration gradient changes.

  9. Study of severe scorpion envenoming following subcutaneous venom injection into dogs: Hemodynamic and concentration/effect analysis.

    PubMed

    Elatrous, Souheil; Ouanes-Besbes, Lamia; Ben Sik-Ali, Habiba; Hamouda, Zineb; BenAbdallah, Saoussen; Tilouche, Nejla; Jalloul, Faten; Fkih-Hassen, Mohamed; Dachraoui, Fahmi; Ouanes, Islem; Abroug, Fekri

    2015-09-15

    To evaluate the dose-effects of Androctonus australis hector (Aah) venom injected subcutaneously on hemodynamics and neurohormonal secretions, 10 anesthetized and ventilated mongrel dogs, were split in two groups (n = 5/group). Subcutaneous injection was done with either 0.2 mg/kg or 0.125 mg/kg of the purified G50 scorpion toxic fraction. Hemodynamic parameters using right heart catheter were recorded and plasma concentrations of catecholamine, troponin, and serum toxic fraction were measured sequentially from baseline to 120 min. We identified the dose of toxic fraction evoking characteristic hemodynamic perturbation of severe envenomation, the time-lapse to envenomation, and the associated plasma level. The injection of 0.125 mg/kg toxic fraction was not associated with significant variations in hemodynamic parameters, whereas the 0.2 mg/kg dose caused envenomation characterized by significant increase in plasma catecholamines, increased pulmonary artery occluded pressure, mean arterial pressure, and systemic vascular resistance (p < 0.05), in association with sustained decline in cardiac output (p < 0.001). Envenomation occurred by the 30th minute, and the corresponding concentration of toxic fraction was 1.14 ng/ml. The current experiment allowed the identification of the sub-lethal dose (0.2 mg/kg) of the toxic fraction of Aah administered by the subcutaneous route. Two parameters with potential clinical relevance were also uncovered: the time-lapse to envenomation and the corresponding concentration of toxic fraction. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Design, fabrication and test of a pneumatically controlled, renewable, microfluidic bead trapping device for sequential injection analysis applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shao, Guocheng; Lu, Donglai; Fu, Zhifeng

    This paper describes the design, fabrication, and testing of a pneumatically controlled,renewable, microfluidic device for conducting bead-based assays in an automated sequential injection analysis system. The device used a “brick wall”-like pillar array (pillar size: 20 μm length X 50 μm width X 45 μm height) with 5 μm gaps between the pillars serving as the micro filter. The flow channel where bead trapping occurred is 500 μm wide X 75 μm deep. An elastomeric membrane and an air chamber were located underneath the flow channel. By applying pressure to the air chamber, the membrane is deformed and pushed upwardmore » against the filter structure. This effectively traps beads larger than 5 μm and creates a “bed” or micro column of beads that can be perfused and washed with liquid samples and reagents. Upon completion of the assay process, the pressure is released and the beads are flushed out from underneath the filter structure to renew the device. Mouse IgG was used as a model analyte to test the feasibility of using the proposed device for immunoassay applications. Resulting microbeads from an on-chip fluorescent immunoassay were individually examined using flow cytometry. The results show that the fluorescence signal intensity distribution is fairly narrow indicating high chemical reaction uniformity among the beads population. Electrochemical onchip assay was also conducted. A detection limit of 0.1 ng/mL1 ppb was achieved and good device reliability and repeatability were demonstrated. The novel microfluidic-based beadstrapping device thus opens up a new pathway to design micro-bead based biosensor immunoassays for clinical and othervarious applications.« less

  11. Monitoring glucose, calcium, and magnesium levels in saliva as a non-invasive analysis by sequential injection multi-parametric determination.

    PubMed

    Machado, Ana; Maneiras, Rui; Bordalo, Adriano A; Mesquita, Raquel B R

    2018-08-15

    The use of saliva for diagnose and surveillance of systemic illnesses, and general health has been arousing great interest worldwide, emerging as a highly desirable goal in healthcare. The collection is non-invasive, stress-free, inexpensive, and simple representing a major asset. Glucose, calcium, and magnesium concentration are three major parameters evaluated in clinical context due to their essential role in a wide range of biochemical reactions, and consequently many health disorders. In this work, a spectrophotometric sequential injection method is described for the fast screening of glucose, calcium, and magnesium in saliva samples. The glucose determination reaction involves the oxidation of the aldehyde functional group present in glucose with simultaneous reduction of 3,5-dinitrosalicylic acid (DNS) to 3-amino, 5-nitrosalicylic acid under alkaline conditions, followed by the development of colour. The determination of both metals is based on their reaction with cresolphtalein complexone (CPC), and the interference of calcium in the magnesium determination minimized by ethylene glycol-bis[β-aminoethyl ether]-N,N,N',N'-tetraacetic acid (EGTA). The developed multi-parametric method enabled dynamic ranges of 50 - 300 mg/dL for glucose, 0.1 - 2 mg/dL for calcium, and 0.1 - 0.5 mg/dL for magnesium. Determination rates of 28, 60, 52 h -1 were achieved for glucose, calcium, and magnesium, respectively. Less than 300 µL of saliva is required for the multi-parametric determination due to saliva viscosity and inherent necessity of dilution prior to analysis. RSDs lower than 5% were obtained, and the results agreed with those obtained by reference methods, while recovery tests confirmed its accuracy. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Solid-phase based on-chip DNA purification through a valve-free stepwise injection of multiple reagents employing centrifugal force combined with a hydrophobic capillary barrier pressure.

    PubMed

    Zhang, Hainan; Tran, Hong Hanh; Chung, Bong Hyun; Lee, Nae Yoon

    2013-03-21

    In this paper, we demonstrate a simple technique for sequentially introducing multiple sample liquids into microchannels driven by centrifugal force combined with a hydrophobic barrier pressure and apply the technique for performing solid-phase based on-chip DNA purification. Three microchannels with varying widths, all equipped with independent sample reservoirs at the inlets, were fabricated on a hydrophobic elastomer, poly(dimethylsiloxane) (PDMS). First, glass beads were packed inside the reaction chamber, and a whole cell containing the DNA extract was introduced into the widest channel by applying centrifugal force for physical adsorption of the DNA onto the glass beads. Next, washing and elution solutions were sequentially introduced into the intermediate and narrowest microchannels, respectively, by gradually increasing the amount of centrifugal force. Through a precise manipulation of the centrifugal force, the DNA adsorbed onto the glass beads was successfully washed and eluted in a continuous manner without the need to introduce each solution manually. A stepwise injection of liquids was successfully demonstrated using multiple ink solutions, the results of which corresponded well with the theoretical analyses. As a practical application, the D1S80 locus of human genomic DNA, which is widely used for forensic purposes, was successfully purified using the microdevice introduced in this study, as demonstrated through successful target amplification. This will pave the way for the construction of a control-free valve system for realizing on-chip DNA purification, which is one of the most labor-intensive and hard-to-miniaturize components, on a greatly simplified and miniaturized platform employing hydrophobic PDMS.

  13. Effects of Combined Simultaneous and Sequential Endostar and Cisplatin Treatment in a Mice Model of Gastric Cancer Peritoneal Metastases.

    PubMed

    Jia, Lin; Ren, Shuguang; Li, Tao; Wu, Jianing; Zhou, Xinliang; Zhang, Yan; Wu, Jianhua; Liu, Wei

    2017-01-01

    Objective . Aimed to study the effects of endostar and cisplatin using an in vivo imaging system (IVIS) in a model of peritoneal metastasis of gastric cancer. Methods . NUGC-4 gastric cancer cells transfected with luciferase gene (NUGC-4-Luc) were injected i.p. into nude mice. One week later, mice were randomly injected i.p.: group 1, cisplatin (d1-3) + endostar (d4-7); group 2, endostar (d1-4) + cisplatin (d5-7); group 3, endostar + cisplatin d1, 4, and 7; group 4, saline for two weeks. One week after the final administration, mice were sacrificed. Bioluminescent data, microvessel density (MVD), and lymphatic vessel density (LVD) were analyzed. Results . Among the four groups, there were no significant differences in the weights and in the number of cancer cell photons on days 1 and 8 ( P > 0.05). On day 15, the numbers in groups 3 and 1 were less than that in group 2 ( P < 0.05). On day 21, group 3 was significantly less than group 2 ( P < 0.05). MVD of group 4 was less than that of groups 1 and 2 ( P < 0.01). There was no significant difference between groups 2 and 3 ( P > 0.05) or in LVD number among the four groups ( P > 0.05). Conclusions . IVIS® was more useful than weight, volume of ascites, and number of peritoneal nodules. The simultaneous group was superior to sequential groups in killing cancer cells and inhibiting vascular endothelium. Cisplatin-endostar was superior to endostar-cisplatin in killing cancer cells, while the latter in inhibiting peritoneal vascular endothelium.

  14. Sequential Bayesian Geostatistical Inversion and Evaluation of Combined Data Worth for Aquifer Characterization at the Hanford 300 Area

    NASA Astrophysics Data System (ADS)

    Murakami, H.; Chen, X.; Hahn, M. S.; Over, M. W.; Rockhold, M. L.; Vermeul, V.; Hammond, G. E.; Zachara, J. M.; Rubin, Y.

    2010-12-01

    Subsurface characterization for predicting groundwater flow and contaminant transport requires us to integrate large and diverse datasets in a consistent manner, and quantify the associated uncertainty. In this study, we sequentially assimilated multiple types of datasets for characterizing a three-dimensional heterogeneous hydraulic conductivity field at the Hanford 300 Area. The datasets included constant-rate injection tests, electromagnetic borehole flowmeter tests, lithology profile and tracer tests. We used the method of anchored distributions (MAD), which is a modular-structured Bayesian geostatistical inversion method. MAD has two major advantages over the other inversion methods. First, it can directly infer a joint distribution of parameters, which can be used as an input in stochastic simulations for prediction. In MAD, in addition to typical geostatistical structural parameters, the parameter vector includes multiple point values of the heterogeneous field, called anchors, which capture local trends and reduce uncertainty in the prediction. Second, MAD allows us to integrate the datasets sequentially in a Bayesian framework such that it updates the posterior distribution, as a new dataset is included. The sequential assimilation can decrease computational burden significantly. We applied MAD to assimilate different combinations of the datasets, and then compared the inversion results. For the injection and tracer test assimilation, we calculated temporal moments of pressure build-up and breakthrough curves, respectively, to reduce the data dimension. A massive parallel flow and transport code PFLOTRAN is used for simulating the tracer test. For comparison, we used different metrics based on the breakthrough curves not used in the inversion, such as mean arrival time, peak concentration and early arrival time. This comparison intends to yield the combined data worth, i.e. which combination of the datasets is the most effective for a certain metric, which will be useful for guiding the further characterization effort at the site and also the future characterization projects at the other sites.

  15. Fuel system for rotary distributor fuel injection pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klopfer, K.H.; Kelly, W.W.

    1993-06-01

    In a fuel injection pump having a drive shaft, a pump rotor driven by the drive shaft, reciprocating pumping means with periodic intake and pumping strokes to periodically receive an intake charge of fuel and deliver fuel at high pressure for fuel injection is described; a distributor head with a plurality of angularly spaced distributor outlets, the pump rotor providing a distributor rotor with a distributor port connected to the pumping means, the distributor rotor being rotatably mounted in the distributor head for sequential registration of the distributor port with the distributor outlets for distributing said high pressure delivery ofmore » fuel thereto; a fuel system for supplying fuel to the pumping means, having an end chamber at one end of the pump rotor and a fuel supply pump driven by the drive shaft and having an inlet and outlet, the supply pump outlet being connected to the end chamber for supplying fuel thereto, and a pressure regulator for regulating the fuel pressure in the end chamber; and a control valve connected between the pumping means and the end chamber and selectively opened during the intake strokes to supply fuel to the pumping means from the end chamber and during the pumping strokes to spill fuel from the pumping means into the end chamber to terminate said high pressure delivery of fuel; the improvement wherein the fuel system comprises a fuel return passage connected in series with the end chamber downstream thereof, wherein the pressure regulator is mounted in the return passage for regulating the upstream fuel pressure, including the upstream fuel pressure within the end chamber, and is connected for conducting excess fuel for return to the supply pump inlet, and wherein the supply pump is driven by the drive shaft to supply fuel at a rate exceeding the rate of said high pressure delivery of fuel for fuel injection and to provide excess fuel flow continuously through the end chamber and return passage to the pressure regulator.« less

  16. Automated thermometric enzyme immunoassay of human proinsulin produced by Escherichia coli.

    PubMed

    Birnbaum, S; Bülow, L; Hardy, K; Danielsson, B; Mosbach, K

    1986-10-01

    We have determined and monitored the production and release of human proinsulin by genetically engineered Escherichia coli cells. Several M9 media samples were analyzed sequentially after centrifugation with the aid of a rapid automated flow-through thermometric enzyme-linked immunosorbent assay (TELISA) system. The response time was 7 min after sample injection and a single assay was complete after 13 min. Insulin concentrations in the range of 0.1-50 micrograms/ml could be determined. The TELISA method correlated well with conventional radioimmunoassay determinations. Standard curves were reproducible over a period of several days even when the immobilized antibody column was stored at 25 degrees C in the enzyme thermistor unit. Thus, immediate assay start up was possible.

  17. A Power-Efficient Wireless Capacitor Charging System Through an Inductive Link

    PubMed Central

    Lee, Hyung-Min; Ghovanloo, Maysam

    2014-01-01

    A power-efficient wireless capacitor charging system for inductively powered applications has been presented. A bank of capacitors can be directly charged from an ac source by generating a current through a series charge injection capacitor and a capacitor charger circuit. The fixed charging current reduces energy loss in switches, while maximizing the charging efficiency. An adaptive capacitor tuner compensates for the resonant capacitance variations during charging to keep the amplitude of the ac input voltage at its peak. We have fabricated the capacitor charging system prototype in a 0.35-μm 4-metal 2-poly standard CMOS process in 2.1 mm2 of chip area. It can charge four pairs of capacitors sequentially. While receiving 2.7-V peak ac input through a 2-MHz inductive link, the capacitor charging system can charge each pair of 1 μF capacitors up to ±2 V in 420 μs, achieving a high measured charging efficiency of 82%. PMID:24678284

  18. A Power-Efficient Wireless Capacitor Charging System Through an Inductive Link.

    PubMed

    Lee, Hyung-Min; Ghovanloo, Maysam

    2013-10-01

    A power-efficient wireless capacitor charging system for inductively powered applications has been presented. A bank of capacitors can be directly charged from an ac source by generating a current through a series charge injection capacitor and a capacitor charger circuit. The fixed charging current reduces energy loss in switches, while maximizing the charging efficiency. An adaptive capacitor tuner compensates for the resonant capacitance variations during charging to keep the amplitude of the ac input voltage at its peak. We have fabricated the capacitor charging system prototype in a 0.35- μ m 4-metal 2-poly standard CMOS process in 2.1 mm 2 of chip area. It can charge four pairs of capacitors sequentially. While receiving 2.7-V peak ac input through a 2-MHz inductive link, the capacitor charging system can charge each pair of 1 μ F capacitors up to ±2 V in 420 μ s, achieving a high measured charging efficiency of 82%.

  19. Synovial and systemic pharmacokinetics (PK) of triamcinolone acetonide (TA) following intra-articular (IA) injection of an extended-release microsphere-based formulation (FX006) or standard crystalline suspension in patients with knee osteoarthritis (OA).

    PubMed

    Kraus, V B; Conaghan, P G; Aazami, H A; Mehra, P; Kivitz, A J; Lufkin, J; Hauben, J; Johnson, J R; Bodick, N

    2018-01-01

    Intra-articular (IA) corticosteroids relieve osteoarthritis (OA) pain, but rapid absorption into systemic circulation may limit efficacy and produce untoward effects. We compared the pharmacokinetics (PK) of IA triamcinolone acetonide (TA) delivered as an extended-release, microsphere-based formulation (FX006) vs a crystalline suspension (TAcs) in knee OA patients. This Phase 2 open-label study sequentially enrolled 81 patients who received a single IA injection of FX006 (5 mL, 32 mg delivered dose, N = 63) or TAcs (1 mL, 40 mg, N = 18). Synovial fluid (SF) aspiration was attempted in each patient at baseline and one post-IA-injection visit (FX006: Week 1, Week 6, Week 12, Week 16 or Week 20; TAcs: Week 6). Blood was collected at baseline and multiple post-injection times. TA concentrations (validated LC-MS/MS, geometric means (GMs)), PK (non-compartmental analysis models), and adverse events (AEs) were assessed. SF TA concentrations following FX006 were quantifiable through Week 12 (pg/mL: 231,328.9 at Week 1; 3590.0 at Week 6; 290.6 at Week 12); post-TAcs, only two of eight patients had quantifiable SF TA at Week 6 (7.7 pg/mL). Following FX006, plasma TA gradually increased to peak (836.4 pg/mL) over 24 h and slowly declined to <110 pg/mL over Weeks 12-20; following TAcs, plasma TA peaked at 4 h (9628.8 pg/mL), decreased to 4991.1 pg/mL at 24 h, and was 149.4 pg/mL at Week 6, the last post-treatment time point assessed. AEs were similar between groups. In knee OA patients, microsphere-based TA delivery via a single IA injection prolonged SF joint residency, diminished peak plasma levels, and thus reduced systemic TA exposure relative to TAcs. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. [Pharmacokinetics and safety of aripiprazole long-acting injection, following multiple deltoid administrations in schizophrenia patients in Japan].

    PubMed

    Ishigooka, Jun; Noda, Takamasa; Nishiyama, Kosuke; Tamaru, Noriko; Shima, Tomoko; Yamasaki, Yumiko; Tadori, Yoshihiro

    2016-06-01

    Aripiprazole once-monthly (AOM) was previously approved for treatment of schizophrenia as monthly injections in the gluteal muscle. The deltoid muscle provides a more accessible injection site. The present study was conducted in Japanese schizophrenia patients as a 24-week, open-label trial that assessed the pharmacokinetics and safety of 5 sequential doses of AOM 400 mg (AOM 400) once every 4 weeks administered in the deltoid muscle. Patients treated with an oral atypical antipsychotic (other than aripiprazole) continued to receive their pre-study medication up to 14 days after the first AOM 400 injection. The completion rate was 76.5% (n = 13/17). Mean aripiprazole plasma C(min) almost reached steady-state by the fourth AOM 400 injection. After the fifth AOM 400 injection, mean aripiprazole AUC(28d), C(max) and C(min) were 165 μg x h/ml, 331 ng/ml and 201 ng/ml, respectively, which were similar to previously published pharmacokinetic parameters after the fifth gluteal injection of AOM 400. The most common treatment-emergent adverse event (TEAE) was injection site pain (35.3%). Most TEAEs were classified as mild in intensity. In conclusion, the deltoid injection of AOM can be considered an alternative route of administration, as deltoid and gluteal injections are interchangeable in terms of aripiprazole plasma concentrations, with no additional safety issues.

  1. A Critical Review of the Impacts of Leaking CO 2 Gas and Brine on Groundwater Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qafoku, Nikolla; Zheng, Liange; Bacon, Diana H.

    2015-09-30

    Geological carbon sequestration (GCS) is a global carbon emission reduction strategy involving the capture of CO 2 emitted from fossil fuel burning power plants, as well as the subsequent injection of the captured CO 2 gas into deep saline aquifers or depleted oil and gas reservoirs. A critical question that arises from the proposed GCS is the potential impacts of CO 2 injection on the quality of drinking-water systems overlying CO 2 sequestration storage sites. Although storage reservoirs are evaluated and selected based on their ability to safely and securely store emplaced fluids, leakage of CO 2 from storage reservoirsmore » is a primary risk factor and potential barrier to the widespread acceptance of geologic CO 2 sequestration (OR Harvey et al. 2013; Y-S Jun et al. 2013; DOE 2007). Therefore, a systematic understanding of how CO 2 leakage would affect the geochemistry of potable aquifers, and subsequently control or affect elemental and contaminant release via sequential and/or simultaneous abiotic and biotic processes and reactions is vital.« less

  2. Dynamic leaching and fractionation of trace elements from environmental solids exploiting a novel circulating-flow platform.

    PubMed

    Mori, Masanobu; Nakano, Koji; Sasaki, Masaya; Shinozaki, Haruka; Suzuki, Shiho; Okawara, Chitose; Miró, Manuel; Itabashi, Hideyuki

    2016-02-01

    A dynamic flow-through microcolumn extraction system based on extractant re-circulation is herein proposed as a novel analytical approach for simplification of bioaccessibility tests of trace elements in sediments. On-line metal leaching is undertaken in the format of all injection (AI) analysis, which is a sequel of flow injection analysis, but involving extraction under steady-state conditions. The minimum circulation times and flow rates required to determine the maximum bioaccessible pools of target metals (viz., Cu, Zn, Cd, and Pb) from lake and river sediment samples were estimated using Tessier's sequential extraction scheme and an acid single extraction test. The on-line AIA method was successfully validated by mass balance studies of CRM and real sediment samples. Tessier's test in on-line AI format demonstrated to be carried out by one third of extraction time (6h against more than 17 h by the conventional method), with better analytical precision (<9.2% against >15% by the conventional method) and significant decrease in blank readouts as compared with the manual batch counterpart. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Effect of short-term sequential administration of nonsteroidal anti-inflammatory drugs on the stomach and proximal portion of the duodenum in healthy dogs.

    PubMed

    Dowers, Kristy L; Uhrig, Samantha R; Mama, Khursheed R; Gaynor, James S; Hellyer, Peter W

    2006-10-01

    To evaluate effects of injection with a nonsteroidal anti-inflammatory drug (NSAID) followed by oral administration of an NSAID on the gastrointestinal tract (GIT) of healthy dogs. 6 healthy Walker Hounds. In a randomized, crossover design, dogs were administered 4 treatments consisting of an SC injection of an NSAID or control solution (day 0), followed by oral administration of an NSAID or inert substance for 4 days (days 1 through 4). Treatment regimens included carprofen (4 mg/kg) followed by inert substance; saline (0.9% NaCl) solution followed by deracoxib (4 mg/kg); carprofen (4 mg/kg) followed by carprofen (4 mg/kg); and carprofen (4 mg/kg) followed by deracoxib (4 mg/kg). Hematologic, serum biochemical, and fecal evaluations were conducted weekly, and clinical scores were obtained daily. Endoscopy of the GIT was performed before and on days 1, 2, and 5 for each treatment. Lesions were scored by use of a 6-point scale. No significant differences existed for clinical data, clinicopathologic data, or lesion scores in the esophagus, cardia, or duodenum. For the gastric fundus, antrum, and lesser curvature, an effect of time was observed for all treatments, with lesions worsening from before to day 2 of treatments but improving by day 5. Sequential administration of NSAIDs in this experiment did not result in clinically important gastroduodenal ulcers. A larger study to investigate the effect of sequential administration of NSAIDs for longer durations and in dogs with signs of acute and chronic pain is essential to substantiate these findings.

  4. Sequential injection ionic liquid dispersive liquid-liquid microextraction for thallium preconcentration and determination with flame atomic absorption spectrometry.

    PubMed

    Anthemidis, Aristidis N; Ioannou, Kallirroy-Ioanna G

    2012-08-01

    A novel, automatic on-line sequential injection dispersive liquid-liquid microextraction (SI-DLLME) method, based on 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim][PF(6)]) ionic liquid as an extractant solvent was developed and demonstrated for trace thallium determination by flame atomic absorption spectrometry. The ionic liquid was on-line fully dispersed into the aqueous solution in a continuous flow format while the TlBr(4)(-) complex was easily migrated into the fine droplets of the extractant due to the huge contact area of them with the aqueous phase. Furthermore, the extractant was simply retained onto the surface of polyurethane foam packed into a microcolumn. No specific conditions like low temperature are required for extractant isolation. All analytical parameters of the proposed method were investigated and optimized. For 15 mL of sample solution, an enhancement factor of 290, a detection limit of 0.86 μg L(-1) and a precision (RSD) of 2.7% at 20.0 μg L(-1) Tl(I) concentration level, was obtained. The developed method was evaluated by analyzing certified reference materials while good recoveries from environmental and biological samples proved that present method was competitive in practical applications.

  5. Iodine speciation in coastal and inland bathing waters and seaweeds extracts using a sequential injection standard addition flow-batch method.

    PubMed

    Santos, Inês C; Mesquita, Raquel B R; Bordalo, Adriano A; Rangel, António O S S

    2015-02-01

    The present work describes the development of a sequential injection standard addition method for iodine speciation in bathing waters and seaweeds extracts without prior sample treatment. Iodine speciation was obtained by assessing the iodide and iodate content, the two inorganic forms of iodine in waters. For the determination of iodide, an iodide ion selective electrode (ISE) was used. The indirect determination of iodate was based on the spectrophotometric determination of nitrite (Griess reaction). For the iodate measurement, a mixing chamber was employed (flow batch approach) to explore the inherent efficient mixing, essential for the indirect determination of iodate. The application of the standard addition method enabled detection limits of 0.14 µM for iodide and 0.02 µM for iodate, together with the direct introduction of the target water samples, coastal and inland bathing waters. The results obtained were in agreement with those obtained by ICP-MS and a colorimetric reference procedure. Recovery tests also confirmed the accuracy of the developed method which was effectively applied to bathing waters and seaweed extracts. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Marker retention in the cochlea following injections through the round window membrane

    PubMed Central

    Salt, Alec N.; Sirjani, Davud B.; Hartsock, Jared J.; Gill, Ruth M.; Plontke, Stefan K.

    2007-01-01

    Local delivery of drugs to the inner ear is increasingly being used in both clinical and experimental studies. Although direct injection of drugs into perilymph appears to be the most promising way of administering drugs quantitatively, no studies have yet demonstrated the pharmacokinetics in perilymph following direct injections. In this study, we have investigated the retention of substance in perilymph following a single injection into the basal turn of scala tympani (ST). The substance injected was a marker, trimethylphenylammonium (TMPA) that can be detected in low concentrations with ion-selective microelectrodes. Perilymph pharmacokinetics of TMPA was assessed using sequential apical sampling to obtain perilymph for analysis. The amount of TMPA retained in perilymph was compared for different injection and sampling protocols. TMPA concentrations measured in fluid samples were close to those predicted by simulations when the injection pipette was sealed into the bony wall of ST but were systematically lower when the injection pipette was inserted through the round window membrane (RWM). In the latter condition it was estimated that over 60% of the injected TMPA was lost due to leakage of perilymph around the injection pipette at a rate estimated to be 0.09 μL/min. The effects of leakage during and after injections through the RWM were dramatically reduced when the round window niche was filled with 1% sodium hyaluronate gel before penetrating the RWM with the injection pipette. The findings demonstrate that in order to perform quantitative drug injections into perilymph, even small rates of fluid leakage at the injection site must be controlled. PMID:17662546

  7. Effects of ammonium on uranium partitioning and kaolinite mineral dissolution.

    PubMed

    Emerson, Hilary P; Di Pietro, Silvina; Katsenovich, Yelena; Szecsody, Jim

    2017-02-01

    Ammonia gas injection is a promising technique for the remediation of uranium within the vadose zone. It can be used to manipulate the pH of a system and cause co-precipitation processes that are expected to remove uranium from the aqueous phase and decrease leaching from the solid phase. The work presented in this paper explores the effects of ammonium and sodium hydroxide on the partitioning of uranium and dissolution of the kaolinite mineral in simplified synthetic groundwaters using equilibrium batch sorption and sequential extraction experiments. It shows that there is a significant increase in uranium removal in systems with divalent cations present in the aqueous phase but not in sodium chloride synthetic groundwaters. Further, the initial conditions of the aqueous phase do not affect the dissolution of kaolinite. However, the type of base treatment does have an effect on mineral dissolution. Published by Elsevier Ltd.

  8. Stability of tacrolimus solutions in polyolefin containers.

    PubMed

    Lee, Jun H; Goldspiel, Barry R; Ryu, Sujung; Potti, Gopal K

    2016-02-01

    Results of a study to determine the stability of tacrolimus solutions stored in polyolefin containers under various temperature conditions are reported. Triplicate solutions of tacrolimus (0.001, 0.01, and 0.1 mg/mL) in 0.9% sodium chloride injection or 5% dextrose injection were prepared in polyolefin containers. Some samples were stored at room temperature (20-25 °C); others were refrigerated (2-8 °C) for 20 hours and then stored at room temperature for up to 28 hours. The solutions were analyzed by stability-indicating high-performance liquid chromatography (HPLC) assay at specified time points over 48 hours. Solution pH was measured and containers were visually inspected at each time point. Stability was defined as retention of at least 90% of the initial tacrolimus concentration. All tested solutions retained over 90% of the initial tacrolimus concentration at all time points, with the exception of the 0.001-mg/mL solution prepared in 0.9% sodium chloride injection, which was deemed unstable beyond 24 hours. At all evaluated concentrations, mean solution pH values did not change significantly over 48 hours; no particle formation was detected. During storage in polyolefin bags at room temperature, a 0.001-mg/mL solution of tacrolimus was stable for 24 hours when prepared in 0.9% sodium chloride injection and for at least 48 hours when prepared in 5% dextrose injection. Solutions of 0.01 and 0.1 mg/mL prepared in either diluent were stable for at least 48 hours, and the 0.01-mg/mL tacrolimus solution was also found to be stable throughout a sequential temperature protocol. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  9. Issues surrounding lethal injection as a means of capital punishment.

    PubMed

    Romanelli, Frank; Whisman, Tyler; Fink, Joseph L

    2008-12-01

    Lethal injection as a method of state-sanctioned capital punishment was initially proposed in the United States in 1977 and used for the first time in 1982. Most lethal injection protocols use a sequential drug combination of sodium thiopental, pancuronium bromide, and potassium chloride. Lethal injection was originally introduced as a more humane form of execution compared with existing mechanical methods such as electrocution, toxic gassing, hanging, or firing squad. Lethal injection has not, however, been without controversy. Several states are considering whether lethal injection meets constitutional scrutiny forbidding cruel and unusual punishment. Recently in the case of Ralph Baze and Thomas C. Bowling, Petitioners, v John D. Rees, Commissioner, Kentucky Department of Corrections et al, the United States Supreme Court upheld the constitutionality of the lethal injection protocol as carried out in the Commonwealth of Kentucky. Most of the debate has surrounded the dosing and procedures used in lethal injection and whether the drug combinations and measures for administering the drugs truly produce a timely, pain-free, and fail-safe death. Many have also raised issues regarding the "medicalization" of execution and the ethics of health care professionals' participation in any part of the lethal injection process. As a result of all these issues, the future of lethal injection as a means of execution in the United States is under significant scrutiny. Outcomes of ongoing legislative and judicial reviews might result in cessation of lethal injection in totality or in alterations involving specific drug combinations or administration procedures.

  10. An analog neural hardware implementation using charge-injection multipliers and neutron-specific gain control.

    PubMed

    Massengill, L W; Mundie, D B

    1992-01-01

    A neural network IC based on a dynamic charge injection is described. The hardware design is space and power efficient, and achieves massive parallelism of analog inner products via charge-based multipliers and spatially distributed summing buses. Basic synaptic cells are constructed of exponential pulse-decay modulation (EPDM) dynamic injection multipliers operating sequentially on propagating signal vectors and locally stored analog weights. Individually adjustable gain controls on each neutron reduce the effects of limited weight dynamic range. A hardware simulator/trainer has been developed which incorporates the physical (nonideal) characteristics of actual circuit components into the training process, thus absorbing nonlinearities and parametric deviations into the macroscopic performance of the network. Results show that charge-based techniques may achieve a high degree of neural density and throughput using standard CMOS processes.

  11. Single well tracer method to evaluate enhanced recovery

    DOEpatents

    Sheely, Jr., Clyde Q.; Baldwin, Jr., David E.

    1978-01-01

    Data useful to evaluate the effectiveness of or to design an enhanced recovery process (the recovery process involving mobilizing and moving hydrocarbons through a hydrocarbon-bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well) are obtained by a process which comprises sequentially: determining hydrocarbon saturation in the formation in a volume in the formation near a well bore penetrating the formation, injecting sufficient of the mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore penetrating the formation, and determining by the single well tracer method a hydrocarbon saturation profile in a volume from which hydrocarbons are moved. The single well tracer method employed is disclosed by U.S. Pat. No. 3,623,842. The process is useful to evaluate surfactant floods, water floods, polymer floods, CO.sub.2 floods, caustic floods, micellar floods, and the like in the reservoir in much less time at greatly reduced costs, compared to conventional multi-well pilot test.

  12. Solvent system selectivities in countercurrent chromatography using Salicornia gaudichaudiana metabolites as practical example with off-line electrospray mass-spectrometry injection profiling.

    PubMed

    Costa, Fernanda das Neves; Jerz, Gerold; Figueiredo, Fabiana de Souza; Winterhalter, Peter; Leitão, Gilda Guimarães

    2015-03-13

    For the development of an efficient two-stage isolation process for high-speed countercurrent chromatography (HSCCC) with focus on principal metabolites from the ethyl acetate extract of the halophyte plant Salicornia gaudichaudiana, separation selectivities of two different biphasic solvent systems with similar polarities were evaluated using the elution and extrusion approach. Efficiency in isolation of target compounds is determined by the solvent system selectivity and their chronological use in multiple separation steps. The system n-hexane-ethyl acetate-methanol-water (0.5:6:0.5:6, v/v/v/v) resulted in a comprehensive separation of polyphenolic glycosides. The system n-hexane-n-butanol-water (1:1:2, v/v/v) was less universal but was highly efficient in the fractionation of positional isomers such as di-substituted cinnamic acid quinic acid derivatives. Multiple metabolite detection performed on recovered HSCCC tube fractions was done with rapid mass-spectrometry profiling by sequential off-line injections to electrospray mass-spectrometry (ESI-MS/MS). Selective ion traces of metabolites delivered reconstituted preparative HSCCC runs. Molecular weight distribution of target compounds in single HSCCC tube fractions and MS/MS fragment data were available. Chromatographic areas with strong co-elution effects and fractions of pure recoverable compounds were visualized. In total 11 metabolites have been identified and monitored. Result of this approach was a fast isolation protocol for S. gaudichaudiana metabolites using two solvent systems in a strategic sequence. The process could easily be scaled-up to larger lab-scale or industrial recovery. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Digital coding of Shuttle TV

    NASA Technical Reports Server (NTRS)

    Habibi, A.; Batson, B.

    1976-01-01

    Space Shuttle will be using a field-sequential color television system for the first few missions, but the present plans are to switch to a NTSC color TV system for future missions. The field-sequential color TV system uses a modified black and white camera, producing a TV signal with a digital bandwidth of about 60 Mbps. This article discusses the characteristics of the Shuttle TV systems and proposes a bandwidth-compression technique for the field-sequential color TV system that could operate at 13 Mbps to produce a high-fidelity signal. The proposed bandwidth-compression technique is based on a two-dimensional DPCM system that utilizes temporal, spectral, and spatial correlation inherent in the field-sequential color TV imagery. The proposed system requires about 60 watts and less than 200 integrated circuits.

  14. Analysis of filter tuning techniques for sequential orbit determination

    NASA Technical Reports Server (NTRS)

    Lee, T.; Yee, C.; Oza, D.

    1995-01-01

    This paper examines filter tuning techniques for a sequential orbit determination (OD) covariance analysis. Recently, there has been a renewed interest in sequential OD, primarily due to the successful flight qualification of the Tracking and Data Relay Satellite System (TDRSS) Onboard Navigation System (TONS) using Doppler data extracted onboard the Extreme Ultraviolet Explorer (EUVE) spacecraft. TONS computes highly accurate orbit solutions onboard the spacecraft in realtime using a sequential filter. As the result of the successful TONS-EUVE flight qualification experiment, the Earth Observing System (EOS) AM-1 Project has selected TONS as the prime navigation system. In addition, sequential OD methods can be used successfully for ground OD. Whether data are processed onboard or on the ground, a sequential OD procedure is generally favored over a batch technique when a realtime automated OD system is desired. Recently, OD covariance analyses were performed for the TONS-EUVE and TONS-EOS missions using the sequential processing options of the Orbit Determination Error Analysis System (ODEAS). ODEAS is the primary covariance analysis system used by the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD). The results of these analyses revealed a high sensitivity of the OD solutions to the state process noise filter tuning parameters. The covariance analysis results show that the state estimate error contributions from measurement-related error sources, especially those due to the random noise and satellite-to-satellite ionospheric refraction correction errors, increase rapidly as the state process noise increases. These results prompted an in-depth investigation of the role of the filter tuning parameters in sequential OD covariance analysis. This paper analyzes how the spacecraft state estimate errors due to dynamic and measurement-related error sources are affected by the process noise level used. This information is then used to establish guidelines for determining optimal filter tuning parameters in a given sequential OD scenario for both covariance analysis and actual OD. Comparisons are also made with corresponding definitive OD results available from the TONS-EUVE analysis.

  15. A prospective randomized study comparing two commercially available types of human embryo culture media: G1-PLUS™/G2-PLUS™ sequential medium (Vitrolife) and the GL BLAST™ sole medium (Ingamed).

    PubMed

    Ceschin, Ianae I; Ribas, Mariana H; Ceschin, Alvaro P; Nishikawa, Lucileine; Rocha, Claudia C; Pic-Taylor, Aline; Baroneza, José Eduardo

    2016-03-01

    To check the efficacy of two types of commercially available embryo culture medium: G1-PLUS™/G2-PLUS™ sequential (Vitrolife, Gothenburg, Sweden) and GV BLAST™ sole (Ingamed, Maringá, Brazil) with regards to fertilization, cleavage, blastocyst and pregnancy rates. Prospective and randomized study conducted from March to July 2015, using the medical records of 60 patients submitted to Intracytoplasmic Sperm Injection techniques (ICSI). Data regarding the age of patients, together with fertilization, cleavage, blastocyst and pregnancy rates, were collected and compared in relation to the: G1-PLUS™/G2-PLUS™ sequential and GV BLAST™ sole mediums. The data were tabulated and compared using the Pearson's Chi-Square test (95% CI). There was no significant difference when comparing patients divided into higher and lower fertility age. No significant statistical difference was noted between the fertilization rates (P=0.59), cleavage (P=0.91), evolution to blastocyst (P=0.33) and total pregnancy (P=0.83) when comparing the embryos cultured in the different media analysed. We conclude that the G1-PLUS™/G2-PLUS™ sequential and GV BLAST™ sole mediums are equally effective with regards to fertilization, cleavage, blastocyst development and total pregnancy rates.

  16. A novel sequential process for remediating rare-earth wastewater.

    PubMed

    Cui, Mingcan; Jang, Min; Kang, Kyounglim; Kim, Dukmin; Snyder, Shane A; Khim, Jeehyeong

    2016-02-01

    A novel and economic sequential process consisting of precipitation, adsorption, and oxidation was developed to remediate actual rare-earth (RE) wastewater containing various toxic pollutants, including radioactive species. In the precipitation step, porous air stones (PAS) containing waste oyster shell (WOS), PASWOS, was prepared and used to precipitate most heavy metals with >97% removal efficiencies. The SEM-EDS analysis revealed that PAS plays a key role in preventing the surface coating of precipitants on the surface of WOS and in releasing the dissolved species of WOS successively. For the adsorption step, a polyurethane (PU) impregnated by coal mine drainage sludge (CMDS), PUCMDS, was synthesized and applied to deplete fluoride (F), arsenic (As), uranium (U), and thorium (Th) that remained after precipitation. The continuous-mode sequential process using PAS(WOS), PU(CMDS), and ozone (O3) had 99.9-100% removal efficiencies of heavy metals, 99.3-99.9% of F and As, 95.8-99.4% of U and Th, and 92.4% of COD(Cr) for 100 days. The sequential process can treat RE wastewater economically and effectively without stirred-tank reactors, pH controller, continuous injection of chemicals, and significant sludge generation, as well as the quality of the outlet met the EPA recommended limits. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Anterograde and retrograde tracing with high molecular weight biotinylated dextran amine through thalamocortical and corticothalamic pathways.

    PubMed

    Zhang, Wenjie; Xu, Dongsheng; Cui, Jingjing; Jing, Xianghong; Xu, Nenggui; Liu, Jianhua; Bai, Wanzhu

    2017-02-01

    Biotinylated dextran amine (BDA) has been used for neural pathway tracing in the central nervous system for many decades, in which high molecular weight BDA appeared to be transported predominantly in the anterograde direction and less in the retrograde direction. In the current study, we reexamined the properties of neural labeling with high molecular weight BDA through a reciprocal neural pathway between thalamus and somatosensory cortex. After injection of BDA into the ventral posteromedial nucleus of thalamus (VPM) in the rat, the BDA labeling was sequentially examined on somatosensory cortex at 3, 5, 7, 10, and 14 survival days. Both of anterogradely labeled axonal terminals and retrogradely labeled neuronal cell bodies were observed simultaneously on the somatosensory cortex. With the increasing of survival times after injection, morphological changes occurred on the labeled axonal arbors and neuronal dendrites, in which the high quality of BDA labeling appeared on the tenth survival day. These results indicate that high molecular weight BDA is not only a sensitive anterograde tracer but also an excellent retrograde marker to be used for tracing through thalamocortical and corticothalamic pathways. And the detailed structure of neural labeling with BDA similar to Golgi-like resolution can be obtained at optimal survival times of animals after the injection of high molecular weight BDA. © 2016 Wiley Periodicals, Inc.

  18. A remediation performance model for enhanced metabolic reductive dechlorination of chloroethenes in fractured clay till

    NASA Astrophysics Data System (ADS)

    Manoli, Gabriele; Chambon, Julie C.; Bjerg, Poul L.; Scheutz, Charlotte; Binning, Philip J.; Broholm, Mette M.

    2012-04-01

    A numerical model of metabolic reductive dechlorination is used to describe the performance of enhanced bioremediation in fractured clay till. The model is developed to simulate field observations of a full scale bioremediation scheme in a fractured clay till and thereby to assess remediation efficiency and timeframe. A relatively simple approach is used to link the fermentation of the electron donor soybean oil to the sequential dechlorination of trichloroethene (TCE) while considering redox conditions and the heterogeneous clay till system (clay till matrix, fractures and sand stringers). The model is tested on lab batch experiments and applied to describe sediment core samples from a TCE-contaminated site. Model simulations compare favorably to field observations and demonstrate that dechlorination may be limited to narrow bioactive zones in the clay matrix around fractures and sand stringers. Field scale simulations show that the injected donor is expected to be depleted after 5 years, and that without donor re-injection contaminant rebound will occur in the high permeability zones and the mass removal will stall at 18%. Long remediation timeframes, if dechlorination is limited to narrow bioactive zones, and the need for additional donor injections to maintain dechlorination activity may limit the efficiency of ERD in low-permeability media. Future work should address the dynamics of the bioactive zones, which is essential to understand for predictions of long term mass removal.

  19. Sequential Pumping and Tracing Experiments Using Packer Systems in a Chalk Aquifer

    NASA Astrophysics Data System (ADS)

    Goderniaux, P.; Poulain, A.

    2016-12-01

    The hydraulic characterization of subsurface geological unit is crucial for many hydrogeological applications. The quantification and the spatial distribution of the related parameters is however not always straightforward. As a consequence, parameters values are often considered as homogeneous over the thickness of an aquifer unit. To try to catch the possible heterogeneity, sequential tracer and pumping tests have been performed between two piezometers, using inflatable packer systems to isolate and study specific sections of the boreholes. The experimental site is composed of two 50m-deep piezometers located in a chalk aquifer, in South-West Belgium. The boreholes are not equipped with any casing or screen, to allow the use of the packers. The chalk is characterized by a high porosity, which enables the storage of large quantities of groundwater, and by fractures where fast preferential flow occurs. Recordings made with a borehole camera system has evidenced the presence of many fractures along the borehole, with a mean density of 2 fractures by meter. The frequency of fracture occurrences is however variable along the borehole. Pumping and tracer tests have been performed (1) using the whole borehole depth, and (2) over specific 1-meter sections, isolated with packers. Results confirm that flow and transport parameters are heterogeneous within the chalk aquifer unit. Groundwater head variations, induced by water pumping or injection, and tracer transfer times are variable according to the studied borehole section. Tests are still going on, and the objective is to have measurements over the whole borehole, to be used for numerical interpretation.

  20. Continuous inline blending of antimisting kerosene

    NASA Technical Reports Server (NTRS)

    Parikh, P.; Yavrouian, A.; Sarohia, V.

    1985-01-01

    A continuous inline blender was developed to blend polymer slurries with a stream of jet A fuel. The viscosity of the slurries ranged widely. The key element of the blender was a static mixer placed immediately downstream of the slurry injection point. A positive displacement gear pump for jet A was employed, and a progressive cavity rotary screw pump was used for slurry pumping. Turbine flow meters were employed for jet A metering while the slurry flow rate was calibrated against the pressure drop in the injection tube. While using one of the FM-9 variant slurries, a provision was made for a time delay between the addition of slurry and the addition of amine sequentially into the jet A stream.

  1. Concomitant or sequential administration of live attenuated japanese encephalitis chimeric virus vaccine and yellow fever 17D vaccine

    PubMed Central

    Nasveld, Peter E; Marjason, Joanne; Bennett, Sonya; Aaskov, John; Elliott, Suzanne; McCarthy, Karen; Kanesa-thasan, Niranjan; Feroldi, Emmanuel

    2010-01-01

    A randomized, double-blind, study was conducted to evaluate the safety, tolerability and immunogenicity of a live attenuated Japanese encephalitis chimeric virus vaccine (JE-CV) co-administered with live attenuated yellow fever (YF) vaccine (YF-17D strain; Stamaril®, Sanofi Pasteur) or administered sequentially. Participants (n = 108) were randomized to receive: YF followed by JE-CV 30 days later, JE followed by YF 30 days later, or the co-administration of JE and YF followed or preceded by placebo 30 days later or earlier. Placebo was used in a double-dummy fashion to ensure masking. Neutralizing antibody titers against JE-CV, YF-17D and selected wild-type JE virus strains was determined using a 50% serum-dilution plaque reduction neutralization test (PRNT50). Seroconversion was defined as the appearance of a neutralizing antibody titer above the assay cut-off post-immunization when not present pre-injection at day 0, or a least a four-fold rise in neutralizing antibody titer measured before the pre-injection day 0 and later post vaccination samples. There were no serious adverse events. Most adverse events (AEs) after JE vaccination were mild to moderate in intensity, and similar to those reported following YF vaccination. Seroconversion to JE-CV was 100% and 91% in the JE/YF and YF/JE sequential vaccination groups, respectively, compared with 96% in the co-administration group. All participants seroconverted to YF vaccine and retained neutralizing titers above the assay cut-off at month six. Neutralizing antibodies against JE vaccine were detected in 82–100% of participants at month six. These results suggest that both vaccines may be successfully co-administered simultaneously or 30 days apart. PMID:20864814

  2. Immunogenicity and safety of zoster vaccine live administered with quadrivalent influenza virus vaccine.

    PubMed

    Levin, Myron J; Buchwald, Ulrike K; Gardner, Julie; Martin, Jason; Stek, Jon E; Brown, Elizabeth; Popmihajlov, Zoran

    2018-01-02

    Randomized, blinded, placebo-controlled trial to evaluate the safety and immunogenicity of ZOSTAVAX™ (ZV) administered concomitantly with quadrivalent inactivated influenza vaccine (IIV4) in adults≥50years of age (NCT02519855). Overall, 440 participants were randomized into the Concomitant Group (CG) and 442 into the Sequential Group (SG). The CG received ZV and IIV4 at separate injection sites on Day 1 and matching placebo at Week 4. The SG received placebo and IIV4 (2015-2016 influenza season) at separate injection sites on Day 1 and ZV at Week 4. Varicella-zoster virus (VZV) antibody geometric mean titer (GMT) and geometric mean fold-rise (GMFR) from baseline to 4weeks postvaccination, measured by glycoprotein enzyme-linked immunosorbent assay (gpELISA) and adjusted for age and prevaccination titer. Influenza strain-specific GMT at baseline and 4weeks postvaccination was measured by hemagglutination inhibition (HAI) assay. Injection-site and systemic adverse experiences (AEs) within 28days following any vaccination and serious AEs throughout the study. The adjusted VZV antibody GMT ratio (CG/SG) was 0.87 (95%CI: 0.80, 0.95), meeting the prespecified noninferiority criterion. The VZV antibody GMFR in the CG was 1.9 (95%CI: 1.76, 2.05), meeting the acceptability criterion. Influenza antibody GMT ratios for A/H1N1, A/H3N2, B/Yamagata and B/Victoria were 1.02 (95%CI: 0.88, 1.18), 1.10 (95%CI: 0.94, 1.29), 1.00 (95%CI: 0.88, 1.14), and 0.99 (95%CI: 0.87, 1.13), respectively. The frequency of vaccine-related injection-site and systemic AEs was comparable between groups. No vaccine-related serious AE was observed. The concomitant administration of ZV and IIV4 to adults≥50years of age induced VZV-specific and influenza-specific antibody responses that were comparable to those following administration of either vaccine alone, and was generally well tolerated. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Solid State Television Camera (CID)

    NASA Technical Reports Server (NTRS)

    Steele, D. W.; Green, W. T.

    1976-01-01

    The design, development and test are described of a charge injection device (CID) camera using a 244x248 element array. A number of video signal processing functions are included which maximize the output video dynamic range while retaining the inherently good resolution response of the CID. Some of the unique features of the camera are: low light level performance, high S/N ratio, antiblooming, geometric distortion, sequential scanning and AGC.

  4. Kinetics of the neuroinflammation-oxidative stress correlation in rat brain following the injection of fibrillar amyloid-beta onto the hippocampus in vivo.

    PubMed

    Rosales-Corral, Sergio; Tan, Dun-Xian; Reiter, Russel J; Valdivia-Velázquez, Miguel; Acosta-Martínez, J Pablo; Ortiz, Genaro G

    2004-05-01

    The purpose of this study was to describe-following the injection of a single intracerebral dose of fibrillar amyloid-beta(1-40) in vivo-some correlations between proinflammatory cytokines and oxidative stress indicators in function of time, as well as how these variables fit in a regression model. We found a positive, significant correlation between interleukin (IL)-1beta or IL-6 and the activity of the glutathione peroxidase enzyme (GSH-Px), but IL-1beta or IL-6 maintained a strong, negative correlation with the lipid peroxidation (LPO). The first 12 h marked a positive correlation between IL-6 and tumor necrosis factor-alpha (TNF-alpha), but starting from the 36 h, this relationship became negative. We found also particular patterns of behavior through the time for IL-1beta, nitrites and IL-6, with parallel or sequential interrelationships. Results shows clearly that, in vivo, the fibrillar amyloid-beta (Abeta) disrupts the oxidative balance and initiate a proinflammatory response, which in turn feeds the oxidative imbalance in a coordinated, sequential way. This work contributes to our understanding of the positive feedbacks, focusing the "cytokine cycle" along with the oxidative stress mediators in a complex, multicellular, and interactive environment.

  5. A 400 MHz Wireless Neural Signal Processing IC With 625 $\\times$ On-Chip Data Reduction and Reconfigurable BFSK/QPSK Transmitter Based on Sequential Injection Locking.

    PubMed

    Teng, Kok-Hin; Wu, Tong; Liu, Xiayun; Yang, Zhi; Heng, Chun-Huat

    2017-06-01

    An 8-channel wireless neural signal processing IC, which can perform real-time spike detection, alignment, and feature extraction, and wireless data transmission is proposed. A reconfigurable BFSK/QPSK transmitter (TX) at MICS/MedRadio band is incorporated to support different data rate requirement. By using an Exponential Component-Polynomial Component (EC-PC) spike processing unit with an incremental principal component analysis (IPCA) engine, the detection of neural spikes with poor SNR is possible while achieving 625× data reduction. For the TX, a dual-channel at 401 MHz and 403.8 MHz are supported by applying sequential injection locked techniques while attaining phase noise of -102 dBc/Hz at 100 kHz offset. From the measurement, error vector magnitude (EVM) of 4.60%/9.55% with power amplifier (PA) output power of -15 dBm is achieved for the QPSK at 8 Mbps and the BFSK at 12.5 kbps. Fabricated in 65 nm CMOS with an active area of 1 mm 2 , the design consumes a total current of 5  ∼ 5.6 mA with a maximum energy efficiency of 0.7 nJ/b.

  6. Bioremediation of PAHs contaminated river sediment by an integrated approach with sequential injection of co-substrate and electron acceptor: Lab-scale study.

    PubMed

    Liu, Tongzhou; Zhang, Zhen; Dong, Wenyi; Wu, Xiaojing; Wang, Hongjie

    2017-11-01

    In this study, the feasibility of employing an integrated bioremediation approach in contaminated river sediment was evaluated. Sequential addition of co-substrate (acetate) and electron acceptor (NO 3 - ) in a two-phase treatment was capable of effectively removing polycyclic aromatic hydrocarbons (PAHs) in river sediment. The residual concentration of total PAHs decreased to far below effect range low (ERL) value within 91 days of incubation, at which concentration it could rarely pose biological impairment. The biodegradation of high molecular weight PAHs were found to be mainly occurred in the sediment treated with co-substrates (i.e. acetate or methanol), in which acetate was found to be more suitable for PAHs degradation. The role of co-substrates in influencing PAHs biodegradation was tentatively discussed herein. Additionally, the sediment odorous problem and blackish appearance were intensively addressed by NO 3 - injection. The results of this study demonstrated that integrating two or more approaches/processes would be a helpful option in sediment remediation. It can lead to a more effective remediation performance, handle multiple contamination issues, as well as mitigate environmental risks caused by one of the single methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Evaluation of an injectable polymeric delivery system for controlled and localized release of biological factors to promote therapeutic angiogenesis

    NASA Astrophysics Data System (ADS)

    Rocker, Adam John

    Cardiovascular disease remains as the leading cause of death worldwide and is frequently associated with partial or full occlusion of coronary arteries. Currently, angioplasty and bypass surgery are the standard approaches for treating patients with these ischemic heart conditions. However, a large number of patients cannot undergo these procedures. Therapeutic angiogenesis provides a minimally invasive tool for treating cardiovascular diseases by inducing new blood vessel growth from the existing vasculature. Angiogenic growth factors can be delivered locally through gene, cell, and protein therapy. Natural and synthetic polymer growth factor delivery systems are under extensive investigation due their widespread applications and promising therapeutic potential. Although biocompatible, natural polymers often suffer from batch-to-batch variability which can cause unpredictable growth factor release rates. Synthetic polymers offer advantages for growth factor delivery as they can be easily modified to control release kinetics. During the angiogenesis process, vascular endothelial growth factor (VEGF) is necessary to initiate neovessel formation while platelet-derived growth factor (PDGF) is needed later to help stabilize and mature new vessels. In the setting of myocardial infarction, additional anti-inflammatory cytokines like IL-10 are needed to help optimize cardiac repair and limit the damaging effects of inflammation following infarction. To meet these angiogenic and anti-inflammatory needs, an injectable polymer delivery system created from a sulfonated reverse thermal gel encapsulating micelle nanoparticles was designed and evaluated. The sulfonate groups on the thermal gel electrostatically bind to VEGF which controls its release rate, while the micelles are loaded with PDGF and are slowly released as the gel degrades. IL-10 was loaded into the system as well and diffused from the gel over time. An in vitro release study was performed which demonstrated the sequential release capabilities of the polymer system. The ability of the polymer system to induce new blood vessel formation was analyzed in vivo using a subcutaneous injection mouse model. Histological assessment was used to quantify blood vessel formation and an inflammatory response which showed that the polymer delivery system demonstrated a significant increase in functional and mature vessel formation while significantly reducing inflammation.

  8. Prime-boost vaccination with plasmid and adenovirus gene vaccines control HER2/neu+ metastatic breast cancer in mice.

    PubMed

    Wang, Xiaoyan; Wang, Jian-Ping; Rao, Xiao-Mei; Price, Janet E; Zhou, Heshan S; Lachman, Lawrence B

    2005-01-01

    Once metastasis has occurred, the possibility of completely curing breast cancer is unlikely, particularly for the 30 to 40% of cancers overexpressing the gene for HER2/neu. A vaccine targeting p185, the protein product of the HER2/neu gene, could have therapeutic application by controlling the growth and metastasis of highly aggressive HER2/neu+ cells. The purpose of this study was to determine the effectiveness of two gene vaccines targeting HER2/neu in preventive and therapeutic tumor models. The mouse breast cancer cell line A2L2, which expresses the gene for rat HER2/neu and hence p185, was injected into the mammary fat pad of mice as a model of solid tumor growth or was injected intravenously as a model of lung metastasis. SINCP-neu, a plasmid containing Sindbis virus genes and the gene for rat HER2/neu, and Adeno-neu, an E1,E2a-deleted adenovirus also containing the gene for rat HER2/neu, were tested as preventive and therapeutic vaccines. Vaccination with SINCP-neu or Adeno-neu before tumor challenge with A2L2 cells significantly inhibited the growth of the cells injected into the mammary fat or intravenously. Vaccination 2 days after tumor challenge with either vaccine was ineffective in both tumor models. However, therapeutic vaccination in a prime-boost protocol with SINCP-neu followed by Adeno-neu significantly prolonged the overall survival rate of mice injected intravenously with the tumor cells. Naive mice vaccinated using the same prime-boost protocol demonstrated a strong serum immunoglobulin G response and p185-specific cellular immunity, as shown by the results of ELISPOT (enzyme-linked immunospot) analysis for IFNgamma. We report herein that vaccination of mice with a plasmid gene vaccine and an adenovirus gene vaccine, each containing the gene for HER2/neu, prevented growth of a HER2/neu-expressing breast cancer cell line injected into the mammary fat pad or intravenously. Sequential administration of the vaccines in a prime-boost protocol was therapeutically effective when tumor cells were injected intravenously before the vaccination. The vaccines induced high levels of both cellular and humoral immunity as determined by in vitro assessment. These findings indicate that clinical evaluation of these vaccines, particularly when used sequentially in a prime-boost protocol, is justified.

  9. Developing a Self-Report-Based Sequential Analysis Method for Educational Technology Systems: A Process-Based Usability Evaluation

    ERIC Educational Resources Information Center

    Lin, Yi-Chun; Hsieh, Ya-Hui; Hou, Huei-Tse

    2015-01-01

    The development of a usability evaluation method for educational systems or applications, called the self-report-based sequential analysis, is described herein. The method aims to extend the current practice by proposing self-report-based sequential analysis as a new usability method, which integrates the advantages of self-report in survey…

  10. A sequential adaptation technique and its application to the Mark 12 IFF system

    NASA Astrophysics Data System (ADS)

    Bailey, John S.; Mallett, John D.; Sheppard, Duane J.; Warner, F. Neal; Adams, Robert

    1986-07-01

    Sequential adaptation uses only two sets of receivers, correlators, and A/D converters which are time multiplexed to effect spatial adaptation in a system with (N) adaptive degrees of freedom. This technique can substantially reduce the hardware cost over what is realizable in a parallel architecture. A three channel L-band version of the sequential adapter was built and tested for use with the MARK XII IFF (identify friend or foe) system. In this system the sequentially determined adaptive weights were obtained digitally but implemented at RF. As a result, many of the post RF hardware induced sources of error that normally limit cancellation, such as receiver mismatch, are removed by the feedback property. The result is a system that can yield high levels of cancellation and be readily retrofitted to currently fielded equipment.

  11. Mechanical System Reliability and Cost Integration Using a Sequential Linear Approximation Method

    NASA Technical Reports Server (NTRS)

    Kowal, Michael T.

    1997-01-01

    The development of new products is dependent on product designs that incorporate high levels of reliability along with a design that meets predetermined levels of system cost. Additional constraints on the product include explicit and implicit performance requirements. Existing reliability and cost prediction methods result in no direct linkage between variables affecting these two dominant product attributes. A methodology to integrate reliability and cost estimates using a sequential linear approximation method is proposed. The sequential linear approximation method utilizes probability of failure sensitivities determined from probabilistic reliability methods as well a manufacturing cost sensitivities. The application of the sequential linear approximation method to a mechanical system is demonstrated.

  12. An effector role for platelets in systemic and local lipopolysaccharide-induced toxicity in mice, mediated by a CD11a- and CD54-dependent interaction with endothelium.

    PubMed Central

    Piguet, P F; Vesin, C; Ryser, J E; Senaldi, G; Grau, G E; Tacchini-Cottier, F

    1993-01-01

    The role of platelets was investigated in two models of lipopolysaccharide (LPS)-induced toxicity in mice: the systemic reaction, provoked by intravenous LPS injection in D-galactosamine-sensitized recipients, which results in host death, and the local reaction, elicited in the skin by sequential injections of LPS and tumor necrosis factor alpha at 24-h intervals, which results in hemorrhagic necrosis. In both models, the depletion of platelets with a rabbit polyclonal or a mouse monoclonal antiplatelet immunoglobulin G afforded significant protection. In the local reaction, studies of the distribution of 111In-labelled platelets as well as optical and electron microscopy showed that platelets are localized in the dermal venules before hemorrhage occurs. Anti-CD11a (LFA-1) and anti-CD54 (ICAM-1) monoclonal antibodies prevented both platelet localization and hemorrhagic necrosis, and these determinants were detected on mouse platelets by immunofluorescence. The antiplatelet monoclonal antibody did not reduce the localization of polymorphonuclear leukocytes in the dermal venules, as shown by histological sections. Thus, in the local reaction, the stimulation with LPS and tumor necrosis factor alpha leads to a binding of platelets to the endothelium of venules by their beta 2 integrins, which seems necessary for the development of the hemorrhagic necrosis. Images PMID:8104895

  13. Flow injection spectrophotometric determination of V(V) involving on-line separation using a poly(vinylidene fluoride-co-hexafluoropropylene)-based polymer inclusion membrane.

    PubMed

    Yaftian, Mohammad Reza; Almeida, M Inês G S; Cattrall, Robert W; Kolev, Spas D

    2018-05-01

    A poly(vinylidene fluoride-co-hexafluoropropylene)-based polymer inclusion membrane (PIM) using Cyphos® IL 101 (i.e. trihexyl(tetradecyl)phosphonium chloride) as the carrier and 2-nitrophenyl octyl ether as a plasticizer in a mass ratio of 55/35/10 was employed for the on-line extractive separation of V(V) prior to its spectrophotometric determination in a flow injection analysis (FIA) system using xylenol orange as the colorimetric reagent. The selectivity of the membrane allowed the determination of V(V) in sulfate solutions in the presence of a variety of cations and anions. The interference of molybdenum(VI) was eliminated by off-line extraction using the same PIM. A univariate sequential optimization of the newly developed FIA system was conducted and under optimal conditions the system is characterized by a linear concentration range of 0.5-8.0mgL -1 , detection limit of 0.08mgL -1 and sample throughput of 4h -1 . The relative standard deviation at the 3mgL -1 level of V(V) was 2.9% based on 8 replicate determinations. The membrane was stable, which was reflected by the standard deviation value for determinations over three consecutive days (24 determinations of 3mgL -1 V(V)) of 3.6%. The newly developed FIA system was applied to the determination of V(V) in water and dietary supplements samples and a good agreement with inductively coupled plasma optical emission spectrometry was observed. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Successful pregnancy after spermatid injection.

    PubMed

    Bernabeu, R; Cremades, N; Takahashi, K; Sousa, M

    1998-07-01

    We present nine cases of spermatid intracytoplasmic injection for the treatment of non-obstructive azoospermia. In eight cases, no elongated spermatids or spermatozoa were found in previous spermiograms or testicular biopsies. In these patients, treatment was performed using ejaculated (n = 6) and testicular (n = 2) retrieved round spermatids (Sa type). In cases where ejaculated round spermatids were used, they were isolated on the day before oocyte retrieval and left in culture for 24 h before intracytoplasmic sperm injection (ICSI). No pregnancy was obtained in either group, although culturing seemed to increase the fertilization rate. In one other case, elongated spermatids were observed in the previous spermiogram and thus a normal ICSI procedure was scheduled. However, on the day of oocyte retrieval, no spermatids could be recovered from fresh sequential ejaculates, and a testicular open biopsy was then performed. Both round and elongated spermatids were found in the testicular tissue, but only the more mature germinal cells (Sb2) were injected. From this case, a normal pregnancy was obtained which resulted in the birth by Caesarean section at 37 weeks of gestation of a normal healthy baby girl, weighing 2700 g.

  15. Method for gasification of deep, thin coal seams. [DOE patent

    DOEpatents

    Gregg, D.W.

    1980-08-29

    A method of gasification of coal in deep, thin seams by using controlled bending subsidence to confine gas flow to a region close to the unconsumed coal face is given. The injection point is moved sequentially around the perimeter of a coal removal area from a production well to sweep out the area to cause the controlled bending subsidence. The injection holes are drilled vertically into the coal seam through the overburden or horizontally into the seam from an exposed coal face. The method is particularly applicable to deep, thin seams found in the eastern United States and at abandoned strip mines where thin seams were surface mined into a hillside or down a modest dip until the overburden became too thick for further mining.

  16. Method for gasification of deep, thin coal seams

    DOEpatents

    Gregg, David W.

    1982-01-01

    A method of gasification of coal in deep, thin seams by using controlled bending subsidence to confine gas flow to a region close to the unconsumed coal face. The injection point is moved sequentially around the perimeter of a coal removal area from a production well to sweep out the area to cause the controlled bending subsidence. The injection holes are drilled vertically into the coal seam through the overburden or horizontally into the seam from an exposed coal face. The method is particularly applicable to deep, thin seams found in the eastern United States and at abandoned strip mines where thin seams were surface mined into a hillside or down a modest dip until the overburden became too thick for further mining.

  17. Sequential air sampler system : its use by the Virginia Department of Highways & Transportation.

    DOT National Transportation Integrated Search

    1975-01-01

    The Department of Highways & Transportation needs an economical and efficient air quality sampling system for meeting requirements on air monitoring for proposed projects located In critical areas. Two sequential air sampling systems, the ERAI and th...

  18. Visualization and in vivo tracking of the exosomes of murine melanoma B16-BL6 cells in mice after intravenous injection.

    PubMed

    Takahashi, Yuki; Nishikawa, Makiya; Shinotsuka, Haruka; Matsui, Yuriko; Ohara, Saori; Imai, Takafumi; Takakura, Yoshinobu

    2013-05-20

    The development of exosomes as delivery vehicles requires understanding how and where exogenously administered exosomes are distributed in vivo. In the present study, we designed a fusion protein consisting of Gaussia luciferase and a truncated lactadherin, gLuc-lactadherin, and constructed a plasmid expressing the fusion protein. B16-BL6 murine melanoma cells were transfected with the plasmid, and exosomes released from the cells were collected by ultracentrifugation. Strong luciferase activity was detected in the fraction containing exosomes, indicating their efficient labeling with gLuc-lactadherin. Then, the labeled B16-BL6 exosomes were intravenously injected into mice, and their tissue distribution was evaluated. Pharmacokinetic analysis of the exosome blood concentration-time profile revealed that B16-BL6 exosomes disappeared very quickly from the blood circulation with a half-life of approximately 2min. Little luciferase activity was detected in the serum at 4h after exosome injection, suggesting rapid clearance of B16-BL6 exosomes in vivo. Moreover, sequential in vivo imaging revealed that the B16-BL6 exosome-derived signals distributed first to the liver and then to the lungs. These results indicate that gLuc-lactadherin labeling is useful for tracing exosomes in vivo and that B16-BL6 exosomes are rapidly cleared from the blood circulation after systemic administration. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Determination of the total acidity in soft drinks using potentiometric sequential injection titration.

    PubMed

    van Staden, J Koos F; Mashamba, M Mulalo G; Stefan, R Raluca I

    2002-12-06

    A potentiometric SI titration system for the determination of total acidity in soft drinks is proposed. The concept is based on the aspiration of the acid soft drink sample between two base zones into a holding coil with the volume of the first base zone twice to that of the second one and channelled by flow reversal through a reaction coil to a potentiometric sensor. A solution of 0.1 mol l(-1) sodium chloride is used as ionic strength adjustment buffer in the carrier stream. The system has been applied to the analysis of some South African soft drinks having a total acidity level of about 0.2-0.3% (w/v). The method has a sample frequency of 45 samples per h with a linear range of 0.1 and 0.6% (w/v). It is easy to use, fully computerised, and gives the results that are comparable to both automated batch titration and manual titration.

  20. Computer-Based Instruction for TRIDENT FBM Training

    DTIC Science & Technology

    1976-06-01

    remote voice feedback to an operator. In this case it is possible to display text which represents the voice messages required during sequential ...provides two main services: (a) the preparation of missiles for sequential launching with self-guidance after launch, and (b) the coordination of...monitor- ing the status of the guidance system in each missile. FCS SWS coordina- tion consists of monitoring systems involved in sequential functions at

  1. High-resolution reflection seismic survey at a CCS site, Taiwan

    NASA Astrophysics Data System (ADS)

    Wang, Chien-Ying; Chung, Chen-Tung; Kuo, Hsuan-Yu; Wu, Ming-shyan; Kuo-Chen, Hao

    2017-04-01

    To control the effect of greenhouse gas on global warming, the reduction of carbon dioxide emission has become a significant international issue in recent years. The capture of carbon dioxide during its manufacturing and storing in adjacent areas are the most economical way. This research uses high-resolution seismic reflection survey to investigate the region around the world's largest coal-fired power plant at Taichung Port, Taiwan. We aim to detect proper geological structures and to evaluate the possible way to store carbon dioxide. This research uses reflection seismic survey with two mini-vibrators and 240 channels to investigate detailed underground structures. The total length of seismic lines is more than 20 kilometers. By aligning sequential seismic lines, we are able to correlate stratigraphic layers over a wide area. Two adjacent wells along the seismic line are used to identified possible formations. The TaiChung Power Plant (TCPP) at Taichung Port is our target which has more cross-tied seismic lines and a seismic line even extending into the sea water. We analyze these seismic profiles to establish the geological model for carbon dioxide storage and evaluate the possibility of storage systems. Furthermore, this research may prepare some baseline data for the future carbon dioxide injection monitoring. The result shows that the geological structures striking 8 degrees east of north and dipping 2.8 degrees to the east. This means that carbon dioxide will migrate toward the sea direction after injection. The structural layers are relatively flat without any sign of faults. Three carbon dioxide storage systems : Mushan Wuchihshan—Paling(bottom), Peiliao—Talu(middle) and Kueichulin—Chinshui(upper) system are identified. All has the proper reservoir with high porosity and capable caprocks more than 100 meters thick. The geological storage of carbon dioxide injected into TCPP site is a feasible, commercial and safe way to reduce the emission of carbon dioxide from TCPP.

  2. An open-pattern droplet-in-oil planar array for single cell analysis based on sequential inkjet printing technology.

    PubMed

    Wang, Chenyu; Liu, Wenwen; Tan, Manqing; Sun, Hongbo; Yu, Yude

    2017-07-01

    Cellular heterogeneity represents a fundamental principle of cell biology for which a readily available single-cell research tool is urgently required. Here, we present a novel method combining cell-sized well arrays with sequential inkjet printing. Briefly, K562 cells with phosphate buffer saline buffer were captured at high efficiency (74.5%) in a cell-sized well as a "primary droplet" and sealed using fluorinated oil. Then, piezoelectric inkjet printing technology was adapted to precisely inject the cell lysis buffer and the fluorogenic substrate, fluorescein-di-β-D-galactopyranoside, as a "secondary droplet" to penetrate the sealing oil and fuse with the "primary droplet." We thereby successfully measured the intracellular β-galactosidase activity of K562 cells at the single-cell level. Our method allows, for the first time, the ability to simultaneously accommodate the high occupancy rate of single cells and sequential addition of reagents while retaining an open structure. We believe that the feasibility and flexibility of our method will enhance its use as a universal single-cell research tool as well as accelerate the adoption of inkjet printing in the study of cellular heterogeneity.

  3. ANALYSIS OF SEQUENTIAL FAILURES FOR ASSESSMENT OF RELIABILITY AND SAFETY OF MANUFACTURING SYSTEMS. (R828541)

    EPA Science Inventory

    Assessment of reliability and safety of a manufacturing system with sequential failures is an important issue in industry, since the reliability and safety of the system depend not only on all failed states of system components, but also on the sequence of occurrences of those...

  4. Hemodynamic analysis of sequential graft from right coronary system to left coronary system.

    PubMed

    Wang, Wenxin; Mao, Boyan; Wang, Haoran; Geng, Xueying; Zhao, Xi; Zhang, Huixia; Xie, Jinsheng; Zhao, Zhou; Lian, Bo; Liu, Youjun

    2016-12-28

    Sequential and single grafting are two surgical procedures of coronary artery bypass grafting. However, it remains unclear if the sequential graft can be used between the right and left coronary artery system. The purpose of this paper is to clarify the possibility of right coronary artery system anastomosis to left coronary system. A patient-specific 3D model was first reconstructed based on coronary computed tomography angiography (CCTA) images. Two different grafts, the normal multi-graft (Model 1) and the novel multi-graft (Model 2), were then implemented on this patient-specific model using virtual surgery techniques. In Model 1, the single graft was anastomosed to right coronary artery (RCA) and the sequential graft was adopted to anastomose left anterior descending (LAD) and left circumflex artery (LCX). While in Model 2, the single graft was anastomosed to LAD and the sequential graft was adopted to anastomose RCA and LCX. A zero-dimensional/three-dimensional (0D/3D) coupling method was used to realize the multi-scale simulation of both the pre-operative and two post-operative models. Flow rates in the coronary artery and grafts were obtained. The hemodynamic parameters were also showed, including wall shear stress (WSS) and oscillatory shear index (OSI). The area of low WSS and OSI in Model 1 was much less than that in Model 2. Model 1 shows optimistic hemodynamic modifications which may enhance the long-term patency of grafts. The anterior segments of sequential graft have better long-term patency than the posterior segments. With rational spatial position of the heart vessels, the last anastomosis of sequential graft should be connected to the main branch.

  5. Comparison of periodontal ligament injection and inferior alveolar nerve block in mandibular primary molars pulpotomy: a randomized control trial.

    PubMed

    Haghgoo, Roza; Taleghani, Ferial

    2015-05-01

    Inferior alveolar nerve block is a common technique for anesthesia of the primary mandibular molars. A number of disadvantages have been shown to be associated with this technique. Periodontal ligament (PDL) injection could be considered as an alternative to inferior alveolar nerve block. The aim of this study was to evaluate the effectiveness of PDL injection in the anesthesia of primary molar pulpotomy with mandibular block. This study was performed using a sequential double-blind randomized trial design. 80 children aged 3-7 years old who required pulpotomy in symmetrical mandibular primary molars were selected. The teeth of these children were anesthetized with periodontal injection on one side of the mandible and block on the other. Pulpotomy was performed on each patient during the same appointment. Signs of discomfort, including hand and body tension and eye movement, the verbal complaint and crying (SEM scale), were evaluated by a dental assistant who was blinded to the treatment allocation of the patients. Finally, the data were analyzed using the exact Fisher test and Pearson Chi-squared exact test. Success rate was 88/75 and 91/25 in the PDL injection and nerve block groups, respectively. There was no statistically significant difference between the two techniques (P = 0.250). Results showed that PDL injection can be used as an alternative to nerve block in pulpotomy of the mandibular primary molars.

  6. Pharmacokinetics of dinalbuphine sebacate and nalbuphine in human after intramuscular injection of dinalbuphine sebacate in an extended-release formulation.

    PubMed

    Tien, Yu En; Huang, Wen-Chuan; Kuo, Hui-Yuan; Tai, Lily; Uang, Yow-Shieng; Chern, Wendy H; Huang, Jin-Ding

    2017-11-01

    Nalbuphine is a semi-synthetic opioid indicated for the relief of moderate to severe pain. Its short half-life requires frequent injections in clinical practice, resulting in a greater incidence of adverse events. A prodrug of nalbuphine has been developed, dinalbuphine sebacate (DNS), dissolved in a simple oil-based injectable formulation, which could deliver and maintain an effective blood level of nalbuphine. An open-label, prospective, two-period study was performed in healthy volunteers to verify the extended blood concentration profile of nalbuphine. Twelve healthy Taiwanese were randomized to receive an intramuscular injection of 20 mg nalbuphine HCl and 150 mg DNS sequentially with a washout period of 5 days. To prevent DNS hydrolysis during sample analysis, the effect of four esterase inhibitors was evaluated in the quantitation of DNS in human whole blood and thenoyltrifluoroacetone was chosen. The bioavailability of nalbuphine from intramuscularly injected DNS relative to that from nalbuphine HCl was 85.4%. The mean absorption time of nalbuphine from DNS was 145.2 h. It took approximately 6 days for the complete release of DNS into the blood stream where DNS was rapidly hydrolysed to nalbuphine; suggesting a single injection of 150 mg DNS in our extended-release formulation could provide long-lasting pain relief. Copyright © 2017 John Wiley & Sons, Ltd.

  7. MSFC Skylab airlock module, volume 1. [systems design and performance

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The history and development of the Skylab Airlock Module and Payload Shroud is presented from initial concept through final design. A summary is given of the Airlock features and systems. System design and performance are presented for the Spent Stage Experiment Support Module, structure and mechanical systems, mass properties, thermal and environmental control systems, EVA/IVA suite system, electrical power system, sequential system, sequential system, and instrumentation system.

  8. Efficacy of premixed versus sequential administration of clonidine as an adjuvant to hyperbaric bupivacaine intrathecally in cesarean section

    PubMed Central

    Sachan, Prachee; Kumar, Nidhi; Sharma, Jagdish Prasad

    2014-01-01

    Background: Density of the drugs injected intrathecally is an important factor that influences spread in the cerebrospinal fluid. Mixing adjuvants with local anesthetics (LA) alters their density and hence their spread compared to when given sequentially in seperate syringes. Aims: To evaluate the efficacy of intrathecal administration of hyperbaric bupivacaine (HB) and clonidine as a mixture and sequentially in terms of block characteristics, hemodynamics, neonatal outcome, and postoperative pain. Setting and Design: Prospective randomized single blind study at a tertiary center from 2010 to 2012. Materials and Methods: Ninety full-term parturient scheduled for elective cesarean sections were divided into three groups on the basis of technique of intrathecal drug administration. Group M received mixture of 75 μg clonidine and 10 mg HB 0.5%. Group A received 75 μg clonidine after administration of 10 mg HB 0.5% through separate syringe. Group B received 75 μg clonidine before HB 0.5% (10 mg) through separate syringe. Statistical analysis used: Observational descriptive statistics, analysis of variance with Bonferroni multiple comparison post hoc test, and Chi-square test. Results: Time to achieve complete sensory and motor block was less in group A and B in which drugs were given sequentially. Duration of analgesia lasted longer in group B (474.3 ± 20.79 min) and group A (472.50 ± 22.11 min) than in group M (337 ± 18.22 min) with clinically insignificant influence on hemodynamic parameters and sedation. Conclusion: Sequential technique reduces time to achieve complete sensory and motor block, delays block regression, and significantly prolongs the duration of analgesia. However, it did not matter much whether clonidine was administered before or after HB. PMID:25886098

  9. Reactive Transport Modeling of Induced Calcite Precipitation Reaction Fronts in Porous Media Using A Parallel, Fully Coupled, Fully Implicit Approach

    NASA Astrophysics Data System (ADS)

    Guo, L.; Huang, H.; Gaston, D.; Redden, G. D.; Fox, D. T.; Fujita, Y.

    2010-12-01

    Inducing mineral precipitation in the subsurface is one potential strategy for immobilizing trace metal and radionuclide contaminants. Generating mineral precipitates in situ can be achieved by manipulating chemical conditions, typically through injection or in situ generation of reactants. How these reactants transport, mix and react within the medium controls the spatial distribution and composition of the resulting mineral phases. Multiple processes, including fluid flow, dispersive/diffusive transport of reactants, biogeochemical reactions and changes in porosity-permeability, are tightly coupled over a number of scales. Numerical modeling can be used to investigate the nonlinear coupling effects of these processes which are quite challenging to explore experimentally. Many subsurface reactive transport simulators employ a de-coupled or operator-splitting approach where transport equations and batch chemistry reactions are solved sequentially. However, such an approach has limited applicability for biogeochemical systems with fast kinetics and strong coupling between chemical reactions and medium properties. A massively parallel, fully coupled, fully implicit Reactive Transport simulator (referred to as “RAT”) based on a parallel multi-physics object-oriented simulation framework (MOOSE) has been developed at the Idaho National Laboratory. Within this simulator, systems of transport and reaction equations can be solved simultaneously in a fully coupled, fully implicit manner using the Jacobian Free Newton-Krylov (JFNK) method with additional advanced computing capabilities such as (1) physics-based preconditioning for solution convergence acceleration, (2) massively parallel computing and scalability, and (3) adaptive mesh refinements for 2D and 3D structured and unstructured mesh. The simulator was first tested against analytical solutions, then applied to simulating induced calcium carbonate mineral precipitation in 1D columns and 2D flow cells as analogs to homogeneous and heterogeneous porous media, respectively. In 1D columns, calcium carbonate mineral precipitation was driven by urea hydrolysis catalyzed by urease enzyme, and in 2D flow cells, calcium carbonate mineral forming reactants were injected sequentially, forming migrating reaction fronts that are typically highly nonuniform. The RAT simulation results for the spatial and temporal distributions of precipitates, reaction rates and major species in the system, and also for changes in porosity and permeability, were compared to both laboratory experimental data and computational results obtained using other reactive transport simulators. The comparisons demonstrate the ability of RAT to simulate complex nonlinear systems and the advantages of fully coupled approaches, over de-coupled methods, for accurate simulation of complex, dynamic processes such as engineered mineral precipitation in subsurface environments.

  10. Revascularization of Left Coronary System Using a Skeletonized Left Internal Mammary Artery - Sequential vs. Separate Grafting.

    PubMed

    Ji, Qiang; Shi, YunQing; Xia, LiMin; Ma, RunHua; Shen, JinQiang; Lai, Hao; Ding, WenJun; Wang, ChunSheng

    2017-12-25

    To evaluate in-hospital and mid-term outcomes of sequential vs. separate grafting of in situ skeletonized left internal mammary artery (LIMA) to the left coronary system in a single-center, propensity-matched study.Methods and Results:After propensity score-matching, 120 pairs of patients undergoing first scheduled isolated coronary artery bypass grafting (CABG) with in situ skeletonized LIMA grafting to the left anterior descending artery (LAD) territory were entered into a sequential group (sequential grafting of LIMA to the diagonal artery and then to the LAD) or a control group (separate grafting of LIMA to the LAD). The in-hospital and follow-up clinical outcomes and follow-up LIMA graft patency were compared. Both propensity score-matched groups had similar in-hospital and follow-up clinical outcomes. Sequential LIMA grafting was not found to be an independent predictor of adverse events. During a follow-up period of 27.0±7.3 months, 99.1% patency for the diagonal site and 98.3% for the LAD site were determined by coronary computed tomographic angiography after sequential LIMA grafting, both of which were similar with graft patency of separate grafting of in situ skeletonized LIMA to the LAD. Revascularization of the left coronary system using a skeletonized LIMA resulted in excellent in-hospital and mid-term clinical outcomes and graft patency using sequential grafting.

  11. Successful outcome after intravenous gasoline injection.

    PubMed

    Domej, Wolfgang; Mitterhammer, Heike; Stauber, Rudolf; Kaufmann, Peter; Smolle, Karl Heinz

    2007-12-01

    Gasoline, ingested intentionally or accidentally, is toxic. The majority of reported cases of gasoline intoxication involve oral ingestion or inhalation. Data are scarce on complications and outcomes following hydrocarbon poisoning by intravenous injection. Following a suicide attempt by intravenous self-injection of 10 ml of gasoline, a 26-year-old medical student was admitted to the intensive care unit (ICU) with hemoptysis, symptoms of acute respiratory failure, chest pain, and severe abdominal cramps. Gas exchange was severely impaired and a chest x-ray indicated chemical pneumonitis. Initial treatment consisted of mechanical ventilation, supportive hyperventilation, administration of nitrogen oxide (NO), and prednisone. Unfortunately, the patient developed multi-organ dysfunction syndrome (MODS) complicated by life-threatening severe vasoplegia within 24 hours after gasoline injection. High doses of vasopressors along with massive amounts of parenteral fluids were necessary. Despite fluid replacement, renal function worsened and required hemofiltration on 5 sequential days. After 12 days of intensive care management, the patient recovered completely and was discharged to a psychiatric care facility. Intravenous gasoline injection causes major injury to the lungs, the organ bearing the first capillary bed encountered. Treatment of gasoline poisoning is symptomatic because no specific antidote is available. Early and aggressive supportive care may be conducive to a favorable outcome with minimal residual pulmonary sequelae.

  12. Sequential bottom-up assembly of mechanically stabilized synthetic cells by microfluidics

    NASA Astrophysics Data System (ADS)

    Weiss, Marian; Frohnmayer, Johannes Patrick; Benk, Lucia Theresa; Haller, Barbara; Janiesch, Jan-Willi; Heitkamp, Thomas; Börsch, Michael; Lira, Rafael B.; Dimova, Rumiana; Lipowsky, Reinhard; Bodenschatz, Eberhard; Baret, Jean-Christophe; Vidakovic-Koch, Tanja; Sundmacher, Kai; Platzman, Ilia; Spatz, Joachim P.

    2018-01-01

    Compartments for the spatially and temporally controlled assembly of biological processes are essential towards cellular life. Synthetic mimics of cellular compartments based on lipid-based protocells lack the mechanical and chemical stability to allow their manipulation into a complex and fully functional synthetic cell. Here, we present a high-throughput microfluidic method to generate stable, defined sized liposomes termed `droplet-stabilized giant unilamellar vesicles (dsGUVs)’. The enhanced stability of dsGUVs enables the sequential loading of these compartments with biomolecules, namely purified transmembrane and cytoskeleton proteins by microfluidic pico-injection technology. This constitutes an experimental demonstration of a successful bottom-up assembly of a compartment with contents that would not self-assemble to full functionality when simply mixed together. Following assembly, the stabilizing oil phase and droplet shells are removed to release functional self-supporting protocells to an aqueous phase, enabling them to interact with physiologically relevant matrices.

  13. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice

    NASA Astrophysics Data System (ADS)

    Evans, Eleanor; Sawiak, Stephen J.; Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T.

    2014-01-01

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time-activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration-time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18F-FDG respectively to ascertain the technique‧s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  14. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice.

    PubMed

    Evans, Eleanor; Sawiak, Stephen J; Ward, Alexander O; Buonincontri, Guido; Hawkes, Robert C; Carpenter, T Adrian

    2014-01-11

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time-activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration-time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18 F-FDG respectively to ascertain the technique's validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  15. Simultaneous Versus Sequential Side-by-Side Bilateral Metal Stent Placement for Malignant Hilar Biliary Obstructions.

    PubMed

    Inoue, Tadahisa; Ishii, Norimitsu; Kobayashi, Yuji; Kitano, Rena; Sakamoto, Kazumasa; Ohashi, Tomohiko; Nakade, Yukiomi; Sumida, Yoshio; Ito, Kiyoaki; Nakao, Haruhisa; Yoneda, Masashi

    2017-09-01

    Endoscopic bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstructions (MHBOs) is technically demanding, and a second SEMS insertion is particularly challenging. A simultaneous side-by-side (SBS) placement technique using a thinner delivery system may mitigate these issues. We aimed to examine the feasibility and efficacy of simultaneous SBS SEMS placement for treating MHBOs using a novel SEMS that has a 5.7-Fr ultra-thin delivery system. Thirty-four patients with MHBOs underwent SBS SEMS placement between 2010 and 2016. We divided the patient cohort into those who underwent sequential (conventional) SBS placement between 2010 and 2014 (sequential group) and those who underwent simultaneous SBS placement between 2015 and 2016 (simultaneous group), and compared the groups with respect to the clinical outcomes. The technical success rates were 71% (12/17) and 100% (17/17) in the sequential and simultaneous groups, respectively, a difference that was significant (P = .045). The median procedure time was significantly shorter in the simultaneous group (22 min) than in the sequential group (52 min) (P = .017). There were no significant group differences in the time to recurrent biliary obstruction (sequential group: 113 days; simultaneous group: 140 days) or other adverse event rates (sequential group: 12%; simultaneous group: 12%). Simultaneous SBS placement using the novel 5.7-Fr SEMS delivery system may be more straightforward and have a higher success rate compared to that with sequential SBS placement. This new method may be useful for bilateral stenting to treat MHBOs.

  16. Electrochemical oxidation coupled with liquid chromatography and mass spectrometry to study the oxidative stability of active pharmaceutical ingredients in solution: A comparison of off-line and on-line approaches.

    PubMed

    Torres, Susana; Brown, Roland; Zelesky, Todd; Scrivens, Garry; Szucs, Roman; Hawkins, Joel M; Taylor, Mark R

    2016-11-30

    Stability studies of pharmaceutical drug products and pharmaceutical active substances are important to research and development in order to fully understand and maintain product quality and safety throughout its shelf-life. Oxidative forced degradation studies are among the different types of stability studies performed by the pharmaceutical industry in order to understand the intrinsic stability of drug molecules. We have been comparing the use of electrochemistry as an alternative oxidative forced degradation method to traditional forced degradation and accelerated stability studies. Using the electrochemical degradation approach the substrate oxidation takes place in a commercially available electrochemical cell and the effluent of the cell can be either a) directly infused into the mass spectrometer or b) injected in a chromatographic column for separation of the different products formed prior to the mass spectrometry analysis. To enable the study of large numbers of different experimental conditions and molecules we developed a new dual pump automated electrochemical screening platform. This system used a HPLC pump and autosampler to load and wash the electrochemical cell and deliver the oxidized sample plug to a second injection loop. This system enabled the automatic sequential analyses of large numbers of different solutions under varied experimental conditions without need for operator intervention during the run sequence. Here we describe the system and evaluate its performance using a test molecule with well characterized stability and compare results to those obtained using an off-line electrochemistry approach. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Learning Sequential Composition Control.

    PubMed

    Najafi, Esmaeil; Babuska, Robert; Lopes, Gabriel A D

    2016-11-01

    Sequential composition is an effective supervisory control method for addressing control problems in nonlinear dynamical systems. It executes a set of controllers sequentially to achieve a control specification that cannot be realized by a single controller. As these controllers are designed offline, sequential composition cannot address unmodeled situations that might occur during runtime. This paper proposes a learning approach to augment the standard sequential composition framework by using online learning to handle unforeseen situations. New controllers are acquired via learning and added to the existing supervisory control structure. In the proposed setting, learning experiments are restricted to take place within the domain of attraction (DOA) of the existing controllers. This guarantees that the learning process is safe (i.e., the closed loop system is always stable). In addition, the DOA of the new learned controller is approximated after each learning trial. This keeps the learning process short as learning is terminated as soon as the DOA of the learned controller is sufficiently large. The proposed approach has been implemented on two nonlinear systems: 1) a nonlinear mass-damper system and 2) an inverted pendulum. The results show that in both cases a new controller can be rapidly learned and added to the supervisory control structure.

  18. Treatment of Cerebral Palsy with Stem Cells: A Report of 17 Cases.

    PubMed

    Abi Chahine, Nassim H; Wehbe, Tarek W; Hilal, Ramzi A; Zoghbi, Victoria V; Melki, Alia E; Habib, Emil B Bou

    2016-05-30

    Cerebral Palsy (CP) is a disabling condition that affects a child's life and his/her family irreversibly. It is usually a non-progressive condition but improvement over time is rarely seen. The condition can be due to prenatal hypoxia, metabolic, genetic, infectious, traumatic or other causes. It is therefore a heterogeneous group that results in functional motor disability associated with different degrees of cognitive abnormalities. There are no treatments that can cure or even improve CP and the best available approach aims at functional, social and nutritional supportive care and counseling. In this paper, we report 17 sequential patients with CP treated with intrathecal administration of Bone Marrow Mononuclear Cells (BMMC). All patients had an uneventful post-injection course with 73% of the evaluable patients treated having a good response using the Gross Motor Function Classification System (GMFCS). The average improvement was 1.3 levels on the GMFCS with cognitive improvements as well.

  19. Determination of the titratable acidity and the pH of wine based on potentiometric flow injection analysis.

    PubMed

    Vahl, Katja; Kahlert, Heike; von Mühlen, Lisandro; Albrecht, Anja; Meyer, Gabriele; Behnert, Jürgen

    2013-07-15

    A FIA system using a pH-sensitive detector based on a graphite/quinhydrone/silicone composite electrode was applied to determine sequentially the titratable acidity and the pH of wine, as well as the sum of calcium and magnesium ions. For all measurements the same FIA configuration was used employing different carrier solutions. The results for the determination of acidity and pH are in good agreement with those obtained by classical potentiometric titrations and by pH measurements using a conventional glass electrode. The standard deviation was less than 1.5% for both kinds of measurements and the sample volume was 150 μL. The method allows about 40 determinations of titratable acidity per hour and 30 pH measurements per hour. The titration method can be adjusted to the legal requirements in USA and Europe. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Extracting dielectric fixed charge density on highly doped crystalline-silicon surfaces using photoconductance measurements

    NASA Astrophysics Data System (ADS)

    To, A.; Hoex, B.

    2017-11-01

    A novel method for the extraction of fixed interface charge, Qf, and the surface recombination parameters, Sn0 and Sp0, from the injection-level dependent effective minority carrier lifetime measurements is presented. Unlike conventional capacitance-voltage measurements, this technique can be applied to highly doped surfaces provided the surface carrier concentration transitions into strong depletion or inversion with increased carrier injection. By simulating the injection level dependent Auger-corrected inverse lifetime curve of symmetrically passivated and diffused samples after sequential annealing and corona charging, it was revealed that Qf, Sn0, and Sp0 have unique signatures. Therefore, these important electronic parameters, in some instances, can independently be resolved. Furthermore, it was shown that this non-linear lifetime behaviour is exhibited on both p-type and n-type diffused inverted surfaces, by demonstrating the approach with phosphorous diffused n+pn+ structures and boron diffused p+np+ structures passivated with aluminium oxide (AlOx) and silicon nitride, respectively (SiNx). The results show that the approximation of a mid-gap Shockley-Read-Hall defect level with equal capture cross sections is able to, in the samples studied in this work, reproduce the observed injection level dependent lifetime behaviour.

  1. Flow analysis techniques for phosphorus: an overview.

    PubMed

    Estela, José Manuel; Cerdà, Víctor

    2005-04-15

    A bibliographical review on the implementation and the results obtained in the use of different flow analytical techniques for the determination of phosphorus is carried out. The sources, occurrence and importance of phosphorus together with several aspects regarding the analysis and terminology used in the determination of this element are briefly described. A classification as well as a brief description of the basis, advantages and disadvantages of the different existing flow techniques, namely; segmented flow analysis (SFA), flow injection analysis (FIA), sequential injection analysis (SIA), all injection analysis (AIA), batch injection analysis (BIA), multicommutated FIA (MCFIA), multisyringe FIA (MSFIA) and multipumped FIA (MPFIA) is also carried out. The most relevant manuscripts regarding the analysis of phosphorus by means of flow techniques are herein classified according to the detection instrumental technique used with the aim to facilitate their study and obtain an overall scope. Finally, the analytical characteristics of numerous flow-methods reported in the literature are provided in the form of a table and their applicability to samples with different matrixes, namely water samples (marine, river, estuarine, waste, industrial, drinking, etc.), soils leachates, plant leaves, toothpaste, detergents, foodstuffs (wine, orange juice, milk), biological samples, sugars, fertilizer, hydroponic solutions, soils extracts and cyanobacterial biofilms are tabulated.

  2. High data rate coding for the space station telemetry links.

    NASA Technical Reports Server (NTRS)

    Lumb, D. R.; Viterbi, A. J.

    1971-01-01

    Coding systems for high data rates were examined from the standpoint of potential application in space-station telemetry links. Approaches considered included convolutional codes with sequential, Viterbi, and cascaded-Viterbi decoding. It was concluded that a high-speed (40 Mbps) sequential decoding system best satisfies the requirements for the assumed growth potential and specified constraints. Trade-off studies leading to this conclusion are viewed, and some sequential (Fano) algorithm improvements are discussed, together with real-time simulation results.

  3. Eco-friendly synthesis of gelatin-capped bimetallic Au-Ag nanoparticles for chemiluminescence detection of anticancer raloxifene hydrochloride.

    PubMed

    Alarfaj, Nawal A; El-Tohamy, Maha F

    2016-09-01

    This study described the utility of green analytical chemistry in the synthesis of gelatin-capped silver, gold and bimetallic gold-silver nanoparticles (NPs). The preparation of nanoparticles was based on the reaction of silver nitrate or chlorauric acid with a 1.0 wt% aqueous gelatin solution at 50°C. The gelatin-capped silver, gold and bimetallic NPs were characterized using transmission electron microscopy, UV-vis, X-ray diffraction and Fourier transform infrared spectroscopy, and were used to enhance a sensitive sequential injection chemiluminescence luminol-potassium ferricyanide system for determination of the anticancer drug raloxifene hydrochloride. The developed method is eco-friendly and sensitive for chemiluminescence detection of the selected drug in its bulk powder, pharmaceutical injections and biosamples. After optimizing the conditions, a linear relationship in the range of 1.0 × 10(-9) to 1.0 × 10(-1)  mol/L was obtained with a limit of detection of 5.0 × 10(-10)  mol/L and a limit of quantification of 1.0 × 10(-9)  mol/L. Statistical treatment and method validation were performed based on ICH guidelines. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. High-throughput flow injection analysis mass spectroscopy with networked delivery of color-rendered results. 2. Three-dimensional spectral mapping of 96-well combinatorial chemistry racks.

    PubMed

    Görlach, E; Richmond, R; Lewis, I

    1998-08-01

    For the last two years, the mass spectroscopy section of the Novartis Pharma Research Core Technology group has analyzed tens of thousands of multiple parallel synthesis samples from the Novartis Pharma Combinatorial Chemistry program, using an in-house developed automated high-throughput flow injection analysis electrospray ionization mass spectroscopy system. The electrospray spectra of these samples reflect the many structures present after the cleavage step from the solid support. The overall success of the sequential synthesis is mirrored in the purity of the expected end product, but the partial success of individual synthesis steps is evident in the impurities in the mass spectrum. However this latter reaction information, which is of considerable utility to the combinatorial chemist, is effectively hidden from view by the very large number of analyzed samples. This information is now revealed at the workbench of the combinatorial chemist by a novel three-dimensional display of each rack's complete mass spectral ion current using the in-house RackViewer Visual Basic application. Colorization of "forbidden loss" and "forbidden gas-adduct" zones, normalization to expected monoisotopic molecular weight, colorization of ionization intensity, and sorting by row or column were used in combination to highlight systematic patterns in the mass spectroscopy data.

  5. On-line diagnosis of sequential systems

    NASA Technical Reports Server (NTRS)

    Sundstrom, R. J.

    1973-01-01

    A model for on-line diagnosis was investigated for discrete-time systems, and resettable sequential systems. Generalized notions of a realization are discussed along with fault tolerance and errors. Further investigation into the theory of on-line diagnosis is recommended for three levels: binary state-assigned level, logical circuit level, and the subsystem-network level.

  6. Adaptive x-ray threat detection using sequential hypotheses testing with fan-beam experimental data (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Thamvichai, Ratchaneekorn; Huang, Liang-Chih; Ashok, Amit; Gong, Qian; Coccarelli, David; Greenberg, Joel A.; Gehm, Michael E.; Neifeld, Mark A.

    2017-05-01

    We employ an adaptive measurement system, based on sequential hypotheses testing (SHT) framework, for detecting material-based threats using experimental data acquired on an X-ray experimental testbed system. This testbed employs 45-degree fan-beam geometry and 15 views over a 180-degree span to generate energy sensitive X-ray projection data. Using this testbed system, we acquire multiple view projection data for 200 bags. We consider an adaptive measurement design where the X-ray projection measurements are acquired in a sequential manner and the adaptation occurs through the choice of the optimal "next" source/view system parameter. Our analysis of such an adaptive measurement design using the experimental data demonstrates a 3x-7x reduction in the probability of error relative to a static measurement design. Here the static measurement design refers to the operational system baseline that corresponds to a sequential measurement using all the available sources/views. We also show that by using adaptive measurements it is possible to reduce the number of sources/views by nearly 50% compared a system that relies on static measurements.

  7. Neuropeptide-Y both Improves and Impairs Delayed Matching-to-Sample Performance in Rats

    DTIC Science & Technology

    1991-01-01

    Neuropeptide Y distribution in the 422 THOMAS AND AHLERS rat brain. Science 221:877-879; 1983. of animal learning. In: Roitblat , H. L.; Bever, T. G.; Terrace, H...Sources of proactive interference in memory. Hillsdale, NJ: Erlbaum; 1976. animal memory. J. Exp. Psychol. (Anim. Behav.) 1456-70; 1988. 32. Roitblat , H...memory processing by neuropeptide Y varies with brain 33. Roitblat , H. L., Scopatz, R. A. Sequential effects in pigeons de- injection site. Brain Res

  8. Early detection of osteoarthritis in rabbits using MRI with a double-contrast agent.

    PubMed

    Onishi, Okihiro; Ikoma, Kazuya; Kido, Masamitsu; Kabuto, Yukichi; Ueshima, Keiichiro; Matsuda, Ken-Ichi; Tanaka, Masaki; Kubo, Toshikazu

    2018-03-13

    Articular cartilage degeneration has been evaluated by magnetic resonance imaging (MRI). However, this method has several problems, including its time-consuming nature and the requirement of a high magnetic field or specialized hardware. The purpose of this study was to sequentially assess early degenerative changes in rabbit knee articular cartilage using MRI with a new double-contrast agent. We induced osteoarthritis (OA) in the right knee of rabbits by anterior cruciate ligament transection and partial medial meniscectomy. Proton density-weighted images and T 2 -calculated images were obtained before and after contrast agent injection into the knee. The signal intensity ratio (SIR) values on the proton density-weighted images were calculated by dividing the signal intensity of the articular cartilage by that of joint fluid. Six rabbits were examined using MRI at 2 (designated 2-w OA) and 4 weeks (4-w OA) after the operation. Histological examination was performed 4 weeks after the operation. One rabbit was histologically examined 2 weeks after the operation. The control consisted of six rabbits that were not subjected to the operation. The SIR values, T 2 values and the thicknesses of the cartilage of the 2-w OA, 4-w OA and the control before and after contrast agent injection were analyzed. The Mankin score and OARSI (Osteoarthritis Research Society International) score were used for the histological evaluation. Significant differences in the SIR and T 2 values of the medial and lateral condyles of the femur were found between the control and the 4-w OA only after contrast agent injection. No significant differences were found in the SIR and T 2 values before contrast agent injection between the control, the 2-w OA and 4-w OA. The thickness of the articular cartilage revealed no significant differences. In the histological assessment, the Mankin score and OARSI score sequentially increased from the control to the 4-w OA. We evaluated the SIR and T 2 values of the knees in a rabbit OA model and a control model using a new double-contrast agent. MRI with this agent enabled OA detection earlier than using conventional MRI.

  9. Description and effects of sequential behavior practice in teacher education.

    PubMed

    Sharpe, T; Lounsbery, M; Bahls, V

    1997-09-01

    This study examined the effects of a sequential behavior feedback protocol on the practice-teaching experiences of undergraduate teacher trainees. The performance competencies of teacher trainees were analyzed using an alternative opportunities for appropriate action measure. Data support the added utility of sequential (Sharpe, 1997a, 1997b) behavior analysis information in systematic observation approaches to teacher education. One field-based undergraduate practicum using sequential behavior (i.e., field systems analysis) principles was monitored. Summarized are the key elements of the (a) classroom instruction provided as a precursor to the practice teaching experience, (b) practice teaching experience, and (c) field systems observation tool used for evaluation and feedback, including multiple-baseline data (N = 4) to support this approach to teacher education. Results point to (a) the strong relationship between sequential behavior feedback and the positive change in four preservice teachers' day-to-day teaching practices in challenging situational contexts, and (b) the relationship between changes in teacher practices and positive changes in the behavioral practices of gymnasium pupils. Sequential behavior feedback was also socially validated by the undergraduate participants and Professional Development School teacher supervisors in the study.

  10. G-sequentially connectedness for topological groups with operations

    NASA Astrophysics Data System (ADS)

    Mucuk, Osman; Cakalli, Huseyin

    2016-08-01

    It is a well-known fact that for a Hausdorff topological group X, the limits of convergent sequences in X define a function denoted by lim from the set of all convergent sequences in X to X. This notion has been modified by Connor and Grosse-Erdmann for real functions by replacing lim with an arbitrary linear functional G defined on a linear subspace of the vector space of all real sequences. Recently some authors have extended the concept to the topological group setting and introduced the concepts of G-sequential continuity, G-sequential compactness and G-sequential connectedness. In this work, we present some results about G-sequentially closures, G-sequentially connectedness and fundamental system of G-sequentially open neighbourhoods for topological group with operations which include topological groups, topological rings without identity, R-modules, Lie algebras, Jordan algebras, and many others.

  11. The effectiveness of Hering's nerve stimulation in controlling penicillin-induced seizures in the rat is dependent on the amygdala.

    PubMed

    Tubbs, R Shane; Wellons, John C; Patwardhan, Ravish V; Oakes, W Jerry; Wyss, J Michael

    2002-11-01

    This study tests the hypothesis that the ability of Hering's nerve stimulation (HNS) to blunt seizure activity is dependent on the availability of dopamine in the amygdala. In 10 rats, Hering's nerve (HN) on the right side was isolated and placed on an electrode and penicillin was locally placed on each rat's left frontoparietal region to induce seizures. After the initiation of seizures, HN was stimulated. After the recurrence of seizure activity, the left basolateral amygdala was injected with 1.0 microl of normal saline, dopamine, haloperidol or 1% lidocaine in sequential tests. HN was stimulated after each injection and the latency and amplitude of the seizure activity were assessed. Focal cortical penicillin induced seizures that resulted in tonic-clonic movement of the limbs and face that lasted 35-45 min. Tonic-clonic movements of the limbs and face of similar latency and amplitude were induced by repeated reapplication of penicillin in untreated rats. HNS decreased seizure activity, but infusion of haloperidol or lidocaine into the basolateral amygdala blocked this antiseizure effect of HNS. In contrast, infusion of saline or dopamine had no effect on the ability of HNS to blunt seizure activity. None of the amygdala injections altered the latency or amplitude of seizure activity. These results demonstrate that the ability of HNS to blunt seizure activity in the rat is dependent on an intact dopamine system in the basolateral amygdala. These data will hopefully be useful in furthering our understanding of the circuitry that allows peripheral nerve stimulation to alter seizure activity. Copyright 2002 S. Karger AG, Basel

  12. Implementing a finite-state off-normal and fault response system for disruption avoidance in tokamaks

    NASA Astrophysics Data System (ADS)

    Eidietis, N. W.; Choi, W.; Hahn, S. H.; Humphreys, D. A.; Sammuli, B. S.; Walker, M. L.

    2018-05-01

    A finite-state off-normal and fault response (ONFR) system is presented that provides the supervisory logic for comprehensive disruption avoidance and machine protection in tokamaks. Robust event handling is critical for ITER and future large tokamaks, where plasma parameters will necessarily approach stability limits and many systems will operate near their engineering limits. Events can be classified as off-normal plasmas events, e.g. neoclassical tearing modes or vertical displacements events, or faults, e.g. coil power supply failures. The ONFR system presented provides four critical features of a robust event handling system: sequential responses to cascading events, event recovery, simultaneous handling of multiple events and actuator prioritization. The finite-state logic is implemented in Matlab®/Stateflow® to allow rapid development and testing in an easily understood graphical format before automated export to the real-time plasma control system code. Experimental demonstrations of the ONFR algorithm on the DIII-D and KSTAR tokamaks are presented. In the most complex demonstration, the ONFR algorithm asynchronously applies ‘catch and subdue’ electron cyclotron current drive (ECCD) injection scheme to suppress a virulent 2/1 neoclassical tearing mode, subsequently shuts down ECCD for machine protection when the plasma becomes over-dense, and enables rotating 3D field entrainment of the ensuing locked mode to allow a safe rampdown, all in the same discharge without user intervention. When multiple ONFR states are active simultaneously and requesting the same actuator (e.g. neutral beam injection or gyrotrons), actuator prioritization is accomplished by sorting the pre-assigned priority values of each active ONFR state and giving complete control of the actuator to the state with highest priority. This early experience makes evident that additional research is required to develop an improved actuator sharing protocol, as well as a methodology to minimize the number and topological complexity of states as the finite-state ONFR system is scaled to a large, highly constrained device like ITER.

  13. Implementing a finite-state off-normal and fault response system for disruption avoidance in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eidietis, N. W.; Choi, W.; Hahn, S. H.

    A finite-state off-normal and fault response (ONFR) system is presented that provides the supervisory logic for comprehensive disruption avoidance and machine protection in tokamaks. Robust event handling is critical for ITER and future large tokamaks, where plasma parameters will necessarily approach stability limits and many systems will operate near their engineering limits. Events can be classified as off-normal plasmas events, e.g. neoclassical tearing modes or vertical displacements events, or faults, e.g. coil power supply failures. The ONFR system presented provides four critical features of a robust event handling system: sequential responses to cascading events, event recovery, simultaneous handling of multiplemore » events and actuator prioritization. The finite-state logic is implemented in Matlab*/Stateflow* to allow rapid development and testing in an easily understood graphical format before automated export to the real-time plasma control system code. Experimental demonstrations of the ONFR algorithm on the DIII-D and KSTAR tokamaks are presented. In the most complex demonstration, the ONFR algorithm asynchronously applies “catch and subdue” electron cyclotron current drive (ECCD) injection scheme to suppress a virulent 2/1 neoclassical tearing mode, subsequently shuts down ECCD for machine protection when the plasma becomes over-dense, and enables rotating 3D field entrainment of the ensuing locked mode to allow a safe rampdown, all in the same discharge without user intervention. When multiple ONFR states are active simultaneously and requesting the same actuator (e.g. neutral beam injection or gyrotrons), actuator prioritization is accomplished by sorting the pre-assigned priority values of each active ONFR state and giving complete control of the actuator to the state with highest priority. This early experience makes evident that additional research is required to develop an improved actuator sharing protocol, as well as a methodology to minimize the number and topological complexity of states as the finite-state ONFR system is scaled to a large, highly constrained device like ITER.« less

  14. Implementing a finite-state off-normal and fault response system for disruption avoidance in tokamaks

    DOE PAGES

    Eidietis, N. W.; Choi, W.; Hahn, S. H.; ...

    2018-03-29

    A finite-state off-normal and fault response (ONFR) system is presented that provides the supervisory logic for comprehensive disruption avoidance and machine protection in tokamaks. Robust event handling is critical for ITER and future large tokamaks, where plasma parameters will necessarily approach stability limits and many systems will operate near their engineering limits. Events can be classified as off-normal plasmas events, e.g. neoclassical tearing modes or vertical displacements events, or faults, e.g. coil power supply failures. The ONFR system presented provides four critical features of a robust event handling system: sequential responses to cascading events, event recovery, simultaneous handling of multiplemore » events and actuator prioritization. The finite-state logic is implemented in Matlab*/Stateflow* to allow rapid development and testing in an easily understood graphical format before automated export to the real-time plasma control system code. Experimental demonstrations of the ONFR algorithm on the DIII-D and KSTAR tokamaks are presented. In the most complex demonstration, the ONFR algorithm asynchronously applies “catch and subdue” electron cyclotron current drive (ECCD) injection scheme to suppress a virulent 2/1 neoclassical tearing mode, subsequently shuts down ECCD for machine protection when the plasma becomes over-dense, and enables rotating 3D field entrainment of the ensuing locked mode to allow a safe rampdown, all in the same discharge without user intervention. When multiple ONFR states are active simultaneously and requesting the same actuator (e.g. neutral beam injection or gyrotrons), actuator prioritization is accomplished by sorting the pre-assigned priority values of each active ONFR state and giving complete control of the actuator to the state with highest priority. This early experience makes evident that additional research is required to develop an improved actuator sharing protocol, as well as a methodology to minimize the number and topological complexity of states as the finite-state ONFR system is scaled to a large, highly constrained device like ITER.« less

  15. Comparison of Periodontal Ligament Injection and Inferior Alveolar Nerve Block in Mandibular Primary Molars Pulpotomy: A Randomized Control Trial

    PubMed Central

    Haghgoo, Roza; Taleghani, Ferial

    2015-01-01

    Background: Inferior alveolar nerve block is a common technique for anesthesia of the primary mandibular molars. A number of disadvantages have been shown to be associated with this technique. Periodontal ligament (PDL) injection could be considered as an alternative to inferior alveolar nerve block. The aim of this study was to evaluate the effectiveness of PDL injection in the anesthesia of primary molar pulpotomy with mandibular block. Methods: This study was performed using a sequential double-blind randomized trial design. 80 children aged 3-7 years old who required pulpotomy in symmetrical mandibular primary molars were selected. The teeth of these children were anesthetized with periodontal injection on one side of the mandible and block on the other. Pulpotomy was performed on each patient during the same appointment. Signs of discomfort, including hand and body tension and eye movement, the verbal complaint and crying (SEM scale), were evaluated by a dental assistant who was blinded to the treatment allocation of the patients. Finally, the data were analyzed using the exact Fisher test and Pearson Chi-squared exact test. Results: Success rate was 88/75 and 91/25 in the PDL injection and nerve block groups, respectively. There was no statistically significant difference between the two techniques (P = 0.250). Conclusion: Results showed that PDL injection can be used as an alternative to nerve block in pulpotomy of the mandibular primary molars. PMID:26028895

  16. Sequential Actions of Rab5 and Rab7 Regulate Endocytosis in the Xenopus Oocyte

    PubMed Central

    Mukhopadhyay, Amitabha; Barbieri, Alejandro M.; Funato, Kouichi; Roberts, Richard; Stahl, Philip D.

    1997-01-01

    To explore the role of GTPases in endocytosis, we developed an assay using Xenopus oocytes injected with recombinant proteins to follow the uptake of the fluid phase marker HRP. HRP uptake was inhibited in cells injected with GTPγS or incubated with aluminum fluoride, suggesting a general role for GTPases in endocytosis. Injection of Rab5 into oocytes, as well as Rab5:Q79L, a mutant with decreased GTPase activity, increased HRP uptake. Injection of Rab5:S34N, the dominant-negative mutant, inhibited HRP uptake. Injection of N-ethylmaleimide–sensitive factor (NSF) stimulated HRP uptake, and ATPase-defective NSF mutants inhibited HRP uptake when coinjected with Rab5:Q79L, confirming a requirement for NSF in endocytosis. Surprisingly, injection of Rab7:WT stimulated both uptake and degradation/activation of HRP. The latter appears to be due to enhanced transport to a late endosomal/prelysosomal degradative compartment that is monensin sensitive. Enhancement of uptake by Rab7 appears to function via an Rab5-sensitive pathway in oocytes since the stimulatory effect of Rab7 was blocked by coinjection of Rab5:S34N. Stimulation of uptake by Rab5 was blocked by Rab5:S34N but not by Rab7:T22N. Our results suggest that Rab7, while functioning downstream of Rab5, may be rate limiting for endocytosis in oocytes. PMID:9087439

  17. Testing a fall risk model for injection drug users.

    PubMed

    Pieper, Barbara; Templin, Thomas N; Goldberg, Allon

    2012-01-01

    Fall risk is a critical component of clinical assessment and has not been examined for persons who have injected illicit drugs and are aging. The aim of this study was to test and develop the Fall Risk Model for Injection Drug Users by examining the relationships among injection drug use, chronic venous insufficiency, lower extremity impairments (i.e., decreased ankle range of motion, reduced calf muscle endurance, and leg pain), age and other covariates, and the Tinetti balance and gait total score as a measure of fall risk. A cross-sectional comparative design was used with four crossed factors. Standardized instruments were used to assess the variables. Moderated multiple regression with linear and quadratic trends in age was used to examine the nature of the relationship between the Tinetti balance and gait total and age and the potential moderating role of injection drug use. A prespecified series of models was tested. Participants (n = 713) were men (46.9%) and women with a mean age of 46.26 years and primarily African American (61.7%) in methadone treatment centers. The fall risk of a 48-year-old leg injector was comparable with the fall risk of a 69-year-old who had not injected drugs. Variables were added to the model sequentially, resulting in some lost significance of some when they were explained by subsequent variables. Final significant variables in the model were employment status, number of comorbidities, ankle range of motion, leg pain, and calf muscle endurance. Fall risk was associated with route of drug use. Lower extremity impairments accounted for the effects of injection drug use and chronic venous insufficiency on risk for falls. Further understanding of fall risk in injection users is necessary as they age, attempt to work, and participate in activities.

  18. Sequential delivery of TAT-HSP27 and VEGF using microsphere/hydrogel hybrid systems for therapeutic angiogenesis.

    PubMed

    Shin, Seung-Hwa; Lee, Jangwook; Lim, Kwang Suk; Rhim, Taiyoun; Lee, Sang Kyung; Kim, Yong-Hee; Lee, Kuen Yong

    2013-02-28

    Ischemic disease is associated with high mortality and morbidity rates, and therapeutic angiogenesis via systemic or local delivery of protein drugs is one potential approach to treat the disease. In this study, we hypothesized that combined delivery of TAT-HSP27 (HSP27 fused with transcriptional activator) and VEGF could enhance the therapeutic efficacy in an ischemic mouse model, and that sequential release could be critical in therapeutic angiogenesis. Alginate hydrogels containing TAT-HSP27 as an anti-apoptotic agent were prepared, and porous PLGA microspheres loaded with VEGF as an angiogenic agent were incorporated into the hydrogels to prepare microsphere/hydrogel hybrid delivery systems. Sequential in vitro release of TAT-HSP27 and VEGF was achieved by the hybrid systems. TAT-HSP27 was depleted from alginate gels in 7 days, while VEGF was continually released for 28 days. The release rate of VEGF was attenuated by varying the porous structures of PLGA microspheres. Sequential delivery of TAT-HSP27 and VEGF was critical to protect against muscle degeneration and fibrosis, as well as to promote new blood vessel formation in the ischemic site of a mouse model. This approach to controlling the sequential release behaviors of multiple drugs could be useful in the design of novel drug delivery systems for therapeutic angiogenesis. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. In situ laser-induced photochemical silver substrate synthesis and sequential SERS detection in a flow cell.

    PubMed

    Herman, Krisztian; Szabó, László; Leopold, Loredana F; Chiş, Vasile; Leopold, Nicolae

    2011-05-01

    A new, simple, and effective approach for multianalyte sequential surface-enhanced Raman scattering (SERS) detection in a flow cell is reported. The silver substrate was prepared in situ by laser-induced photochemical synthesis. By focusing the laser on the 320 μm inner diameter glass capillary at 0.5 ml/min continuous flow of 1 mM silver nitrate and 10 mM sodium citrate mixture, a SERS active silver spot on the inner wall of the glass capillary was prepared in a few seconds. The test analytes, dacarbazine, 4-(2-pyridylazo)resorcinol (PAR) complex with Cu(II), and amoxicillin, were sequentially injected into the flow cell. Each analyte was adsorbed to the silver surface, enabling the recording of high intensity SERS spectra even at 2 s integration times, followed by desorption from the silver surface and being washed away from the capillary. Before and after each analyte passed the detection window, citrate background spectra were recorded, and thus, no "memory effects" perturbed the SERS detection. A good reproducibility of the SERS spectra obtained under flow conditions was observed. The laser-induced photochemically synthesized silver substrate enables high Raman enhancement, is characterized by fast preparation with a high success rate, and represents a valuable alternative for silver colloids as SERS substrate in flow approaches.

  20. Kinetic Titration Series with Biolayer Interferometry

    PubMed Central

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647

  1. Kinetic titration series with biolayer interferometry.

    PubMed

    Frenzel, Daniel; Willbold, Dieter

    2014-01-01

    Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1-42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations.

  2. Targeted Drug Delivery in the Suprachoroidal Space by Swollen Hydrogel Pushing.

    PubMed

    Jung, Jae Hwan; Desit, Patcharin; Prausnitz, Mark R

    2018-04-01

    The purpose is to target model drug particles to the posterior region of the suprachoroidal space (SCS) of the eye controlled via pushing by hydrogel swelling. A particle formulation containing 1% hyaluronic acid (HA) with fluorescent polymer particles and a hydrogel formulation containing 4% HA were introduced in a single syringe as two layers without mixing, and injected sequentially into the SCS of the rabbit eye ex vivo and in vivo using a microneedle. Distribution of particles in the eye was determined by microscopy. During injection, the particle formulation was pushed toward the middle of the SCS by the viscous hydrogel formulation, but less than 12% of particles reached the posterior SCS. After injection, the particle formulation was pushed further toward the macula and optic nerve in the posterior SCS by hydrogel swelling and spreading. Heating the eye to 37°C, or injecting in vivo decreased viscosity and mechanical strength of the hydrogel, thereby allowing it to swell and flow further in the SCS. A high salt concentration (9% NaCl) in the hydrogel formulation further increased hydrogel swelling due to osmotic flow into the hydrogel. In this way, up to 76% of particles were delivered to the posterior SCS from an injection made near the limbus. This study shows that model drug particles can be targeted to the posterior SCS by HA hydrogel swelling and pushing without particle functionalization or administering external driving forces.

  3. Histopathological Alterations after Single Epidural Injection of Ropivacaine, Methylprednizolone Acetate, or Contrast Material in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kitsou, Maria-Chrysanthi; Kostopanagiotou, Georgia; Kalimeris, Konstantinos

    Purpose: The consequences from the injection of different types of drugs in the epidural space remains unknown. Increasing evidence suggests that localized inflammation, fibrosis, and arachnoiditis can complicate sequential epidural blockades, or even epidural contrast injection. We investigate the in vivo effect of epidural injections in the epidural space in an animal model. Materials and Methods: A group of ten male adult pigs, five punctures to each at distinct vertebral interspaces under general anesthesia, were examined, testing different drugs, used regularly in the epidural space (iopamidol, methylprednisolone acetate, ropivacaine). Each site was marked with a percutaneous hook wire marker. Histologicalmore » analysis of the epidural space, the meninges, and the underlying spinal cord of the punctured sites along with staining for caspase-3 followed 20 days later. Results: The epidural space did not manifest adhesions or any other pathology, and the outer surface of the dura was not impaired in any specimen. The group that had the contrast media injection showed a higher inflammation response compared to the other groups (P = 0.001). Positive staining for caspase-3 was limited to <5% of neurons with all substances used. Conclusion: No proof of arachnoiditis and/or fibrosis was noted in the epidural space with the use of the above-described drugs. A higher inflammation rate was noted with the use of contrast media.« less

  4. Measurement of density and affinity for dopamine D2 receptors by a single positron emission tomography scan with multiple injections of [11C]raclopride

    PubMed Central

    Ikoma, Yoko; Watabe, Hiroshi; Hayashi, Takuya; Miyake, Yoshinori; Teramoto, Noboru; Minato, Kotaro; Iida, Hidehiro

    2010-01-01

    Positron emission tomography (PET) with [11C]raclopride has been used to investigate the density (Bmax) and affinity (Kd) of dopamine D2 receptors related to several neurological and psychiatric disorders. However, in assessing the Bmax and Kd, multiple PET scans are necessary under variable specific activities of administered [11C]raclopride, resulting in a long study period and unexpected physiological variations. In this paper, we have developed a method of multiple-injection graphical analysis (MI-GA) that provides the Bmax and Kd values from a single PET scan with three sequential injections of [11C]raclopride, and we validated the proposed method by performing numerous simulations and PET studies on monkeys. In the simulations, the three-injection protocol was designed according to prior knowledge of the receptor kinetics, and the errors of Bmax and Kd estimated by MI-GA were analyzed. Simulations showed that our method could support the calculation of Bmax and Kd, despite a slight overestimation compared with the true magnitudes. In monkey studies, we could calculate the Bmax and Kd of diseased or normal striatum in a 150 mins scan with the three-injection protocol of [11C]raclopride. Estimated Bmax and Kd values of D2 receptors in normal or partially dopamine-depleted striatum were comparable to the previously reported values. PMID:19904285

  5. Microbially Enhanced Oil Recovery by Sequential Injection of Light Hydrocarbon and Nitrate in Low- And High-Pressure Bioreactors.

    PubMed

    Gassara, Fatma; Suri, Navreet; Stanislav, Paul; Voordouw, Gerrit

    2015-10-20

    Microbially enhanced oil recovery (MEOR) often involves injection of aqueous molasses and nitrate to stimulate resident or introduced bacteria. Use of light oil components like toluene, as electron donor for nitrate-reducing bacteria (NRB), offers advantages but at 1-2 mM toluene is limiting in many heavy oils. Because addition of toluene to the oil increased reduction of nitrate by NRB, we propose an MEOR technology, in which water amended with light hydrocarbon below the solubility limit (5.6 mM for toluene) is injected to improve the nitrate reduction capacity of the oil along the water flow path, followed by injection of nitrate, other nutrients (e.g., phosphate) and a consortium of NRB, if necessary. Hydrocarbon- and nitrate-mediated MEOR was tested in low- and high-pressure, water-wet sandpack bioreactors with 0.5 pore volumes of residual oil in place (ROIP). Compared to control bioreactors, those with 11-12 mM of toluene in the oil (gained by direct addition or by aqueous injection) and 80 mM of nitrate in the aqueous phase produced 16.5 ± 4.4% of additional ROIP (N = 10). Because toluene is a cheap commodity chemical, HN-MEOR has the potential to be a cost-effective method for additional oil production even in the current low oil price environment.

  6. Evaluation of TDRSS-user orbit determination accuracy using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Hodjatzadeh, M.; Samii, M. V.; Doll, C. E.; Hart, R. C.; Mistretta, G. D.

    1991-01-01

    The development of the Real-Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination on a Disk Operating System (DOS) based Personal Computer (PC) is addressed. The results of a study to compare the orbit determination accuracy of a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOD/E with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), is addressed. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for the Earth Radiation Budget Satellite (ERBS); the maximum solution differences were less than 25 m after the filter had reached steady state.

  7. Structural and spectrophotometric characterization of 2-[4-(dimethylamino)styryl]-1-ethylquinolinium iodide as a reagent for sequential injection determination of tungsten

    NASA Astrophysics Data System (ADS)

    Bazel, Yaroslav; Lešková, Martina; Rečlo, Michal; Šandrejová, Jana; Simon, András; Fizer, Maksym; Sidey, Vasyl

    2018-05-01

    Structure, spectrophotometric and protolytic properties of the styryl dye 2-[4-(dimethylamino)styryl]-1-ethylquinolinium iodide (R) as well as its complex with tungsten were studied. The selective protonation of dimethylamino group was confirmed by density functional theory investigation through the computation of Fukui function, NPA partial atomic charges, and NICS(0) aromaticity indexes. The TD-DFT study explains the experimental change of color by excluding the dimethylamino group from HOMO orbital upon protonation. The acid dissociation constant, the optimum wavelength and the molar absorptivity of R were found to be: 3.02, 501 nm and 4.0 × 104 L mol-1 cm-1, respectively. The protolytic properties of the reagent were found to change significantly in the presence of tungsten(VI). Analysis of bond critical points between the anions and Quinaldine Red cation gives the selectivity raw HWO4- > MoO4-> H2VO4- > ReO4- > ClO4-, that perfectly match with the experimental data. Based on this observation, a non-extractive sequential-injection spectrophotometric method for the determination of tungsten was developed. The absorbance of the colored extracts obeys Beer's law up to 55.2 mg L-1 of W at 520 nm wavelength. The limit of detection calculated from a blank test (n = 10) based on 3 s was 0.96 mg L-1. The developed method was applied for the determination of tungsten in model samples.

  8. Sequential changes in the expression of Wnt- and Notch-related genes in the vagina and uterus of ovariectomized mice after estrogen exposure.

    PubMed

    Nakamura, Takeshi; Miyagawa, Shinichi; Katsu, Yoshinao; Sato, Tomomi; Iguchi, Taisen; Ohta, Yasuhiko

    2012-01-01

    Estrogen regulates morphological changes in reproductive organs, such as the vagina and uterus, during the estrous cycles in mice. Estrogen depletion by ovariectomy in adults results in atrophy accompanied by apoptosis in vaginal and uterine cells, while estrogen treatment following ovariectomy elicits cell proliferation in both organs. Sequential changes in mRNA expression of wingless-related MMTV integration site (Wnt) and Notch signaling genes were analyzed in the vagina and uterus of ovariectomized adult mice after a single injection of 17β-estradiol to provide understanding over the molecular basis of differences in response to estrogen in these organs. We found estrogen-dependent up-regulation of Wnt4, Wnt5a and p21 and down-regulation of Wnt11, hairy/enhancer-of-split related with YRPW motif-1 (Hey1) and delta-like 4 (Dll4) in the vagina, and up-regulation of Wnt4, Wnt5a, Hey1, Heyl, Dll1, p21 and p53 and down-regulation of Wnt11, Hey2 and Dll4 in the uterus. The expression of Wnt4, Hey1, Hey2, Heyl, Dll1 and p53 showed different patterns after the estrogen injection. Expression patterns for Wnt5a, Wnt11, Dll4 and p21 in the vagina and uterus were similar, suggesting that these genes are involved in the proliferation of cells in both those organs in mice.

  9. Monitoring tumor metastases and osteolytic lesions with bioluminescence and micro CT imaging.

    PubMed

    Lim, Ed; Modi, Kshitij; Christensen, Anna; Meganck, Jeff; Oldfield, Stephen; Zhang, Ning

    2011-04-14

    Following intracardiac delivery of MDA-MB-231-luc-D3H2LN cells to Nu/Nu mice, systemic metastases developed in the injected animals. Bioluminescence imaging using IVIS Spectrum was employed to monitor the distribution and development of the tumor cells following the delivery procedure including DLIT reconstruction to measure the tumor signal and its location. Development of metastatic lesions to the bone tissues triggers osteolytic activity and lesions to tibia and femur were evaluated longitudinally using micro CT. Imaging was performed using a Quantum FX micro CT system with fast imaging and low X-ray dose. The low radiation dose allows multiple imaging sessions to be performed with a cumulative X-ray dosage far below LD50. A mouse imaging shuttle device was used to sequentially image the mice with both IVIS Spectrum and Quantum FX achieving accurate animal positioning in both the bioluminescence and CT images. The optical and CT data sets were co-registered in 3-dimentions using the Living Image 4.1 software. This multi-mode approach allows close monitoring of tumor growth and development simultaneously with osteolytic activity.

  10. Developing automated analytical methods for scientific environments using LabVIEW.

    PubMed

    Wagner, Christoph; Armenta, Sergio; Lendl, Bernhard

    2010-01-15

    The development of new analytical techniques often requires the building of specially designed devices, each requiring its own dedicated control software. Especially in the research and development phase, LabVIEW has proven to be one highly useful tool for developing this software. Yet, it is still common practice to develop individual solutions for different instruments. In contrast to this, we present here a single LabVIEW-based program that can be directly applied to various analytical tasks without having to change the program code. Driven by a set of simple script commands, it can control a whole range of instruments, from valves and pumps to full-scale spectrometers. Fluid sample (pre-)treatment and separation procedures can thus be flexibly coupled to a wide range of analytical detection methods. Here, the capabilities of the program have been demonstrated by using it for the control of both a sequential injection analysis - capillary electrophoresis (SIA-CE) system with UV detection, and an analytical setup for studying the inhibition of enzymatic reactions using a SIA system with FTIR detection.

  11. Digital Image Speckle Correlation for the Quantification of the Cosmetic Treatment with Botulinum Toxin Type A (BTX-A)

    NASA Astrophysics Data System (ADS)

    Bhatnagar, Divya; Conkling, Nicole; Rafailovich, Miriam; Dagum, Alexander

    2012-02-01

    The skin on the face is directly attached to the underlying muscles. Here, we successfully introduce a non-invasive, non-contact technique, Digital Image Speckle Correlation (DISC), to measure the precise magnitude and duration of facial muscle paralysis inflicted by BTX-A. Subjective evaluation by clinicians and patients fail to objectively quantify the direct effect and duration of BTX-A on the facial musculature. By using DISC, we can (a) Directly measure deformation field of the facial skin and determine the locus of facial muscular tension(b)Quantify and monitor muscular paralysis and subsequent re-innervation following injection; (c) Continuously correlate the appearance of wrinkles and muscular tension. Two sequential photographs of slight facial motion (frowning, raising eyebrows) are taken. DISC processes the images to produce a vector map of muscular displacement from which spatially resolved information is obtained regarding facial tension. DISC can track the ability of different muscle groups to contract and can be used to predict the site of injection, quantify muscle paralysis and the rate of recovery following BOTOX injection.

  12. Redesigning flow injection after 40 years of development: Flow programming.

    PubMed

    Ruzicka, Jaromir Jarda

    2018-01-01

    Automation of reagent based assays, by means of Flow Injection (FI), is based on sample processing, in which a sample flows continuously towards and through a detector for quantification of the target analyte. The Achilles heel of this methodology, the legacy of Auto Analyzer®, is continuous reagent consumption, and continuous generation of chemical waste. However, flow programming, assisted by recent advances in precise pumping, combined with the lab-on-valve technique, allows the FI manifold to be designed around a single confluence point through which sample and reagents are sequentially directed by means of a series of flow reversals. This approach results in sample/reagent mixing analogous to the traditional FI, reduces sample and reagent consumption, and uses the stop flow technique for enhancement of the yield of chemical reactions. The feasibility of programmable Flow Injection (pFI) is documented by example of commonly used spectrophotometric assays of, phosphate, nitrate, nitrite and glucose. Experimental details and additional information are available in online tutorial http://www.flowinjectiontutorial.com/. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Feasibility of simultaneous PET/MR of the carotid artery: first clinical experience and comparison to PET/CT

    PubMed Central

    Ripa, Rasmus S; Knudsen, Andreas; Hag, Anne Mette F; Lebech, Anne-Mette; Loft, Annika; Keller, Sune H; Hansen, Adam E; von Benzon, Eric; Højgaard, Liselotte; Kjær, Andreas

    2013-01-01

    The study aimed at comparing PET/MR to PET/CT for imaging the carotid arteries in patients with known increased risk of atherosclerosis. Six HIV-positive men underwent sequential PET/MR and PET/CT of the carotid arteries after injection of 400 MBq of 18F-FDG. PET/MR was performed a median of 131 min after injection. Subsequently,PET/CT was performed. Regions of interest (ROI) were drawn slice by slice to include the carotid arteries and standardized uptake values (SUV) were calculated from both datasets independently. Quantitative comparison of 18F-FDG uptake revealed a high congruence between PET data acquired using the PET/MR system compared to the PET/CT system. The mean difference for SUVmean was -0.18 (p < 0.001) and -0.14 for SUVmax (p < 0.001) indicating a small but significant bias towards lower values using the PET/MR system. The 95% limits of agreement were -0.55 to 0.20 for SUVmean and -0.93 to 0.65 for SUVmax. The image quality of the PET/MR allowed for delineation of the carotid vessel wall. The correlations between 18F-FDG uptake from ROI including both vessel wall and vessel lumen to ROI including only the wall were strong (r = 0.98 for SUVmean and r = 1.00 for SUVmax) indicating that the luminal 18F-FDG content had minimal influence on the values. The study shows for the first time that simultaneous PET/MR of the carotid arteries is feasible in patients with increased risk of atherosclerosis. Quantification of 18F-FDG uptake correlated well between PET/MR and PET/CT despite difference in method of PET attenuation correction, reconstruction algorithm, and detector technology. PMID:23900769

  14. Bioinspired Nanocomplex for Spatiotemporal Imaging of Sequential mRNA Expression in Differentiating Neural Stem Cells

    PubMed Central

    2015-01-01

    Messenger RNA plays a pivotal role in regulating cellular activities. The expression dynamics of specific mRNA contains substantial information on the intracellular milieu. Unlike the imaging of stationary mRNAs, real-time intracellular imaging of the dynamics of mRNA expression is of great value for investigating mRNA biology and exploring specific cellular cascades. In addition to advanced imaging methods, timely extracellular stimulation is another key factor in regulating the mRNA expression repertoire. The integration of effective stimulation and imaging into a single robust system would significantly improve stimulation efficiency and imaging accuracy, producing fewer unwanted artifacts. In this study, we developed a multifunctional nanocomplex to enable self-activating and spatiotemporal imaging of the dynamics of mRNA sequential expression during the neural stem cell differentiation process. This nanocomplex showed improved enzymatic stability, fast recognition kinetics, and high specificity. With a mechanism regulated by endogenous cell machinery, this nanocomplex realized the successive stimulating motif release and the dynamic imaging of chronological mRNA expression during neural stem cell differentiation without the use of transgenetic manipulation. The dynamic imaging montage of mRNA expression ultimately facilitated genetic heterogeneity analysis. In vivo lateral ventricle injection of this nanocomplex enabled endogenous neural stem cell activation and labeling at their specific differentiation stages. This nanocomplex is highly amenable as an alternative tool to explore the dynamics of intricate mRNA activities in various physiological and pathological conditions. PMID:25494492

  15. Bioinspired nanocomplex for spatiotemporal imaging of sequential mRNA expression in differentiating neural stem cells.

    PubMed

    Wang, Zhe; Zhang, Ruili; Wang, Zhongliang; Wang, He-Fang; Wang, Yu; Zhao, Jun; Wang, Fu; Li, Weitao; Niu, Gang; Kiesewetter, Dale O; Chen, Xiaoyuan

    2014-12-23

    Messenger RNA plays a pivotal role in regulating cellular activities. The expression dynamics of specific mRNA contains substantial information on the intracellular milieu. Unlike the imaging of stationary mRNAs, real-time intracellular imaging of the dynamics of mRNA expression is of great value for investigating mRNA biology and exploring specific cellular cascades. In addition to advanced imaging methods, timely extracellular stimulation is another key factor in regulating the mRNA expression repertoire. The integration of effective stimulation and imaging into a single robust system would significantly improve stimulation efficiency and imaging accuracy, producing fewer unwanted artifacts. In this study, we developed a multifunctional nanocomplex to enable self-activating and spatiotemporal imaging of the dynamics of mRNA sequential expression during the neural stem cell differentiation process. This nanocomplex showed improved enzymatic stability, fast recognition kinetics, and high specificity. With a mechanism regulated by endogenous cell machinery, this nanocomplex realized the successive stimulating motif release and the dynamic imaging of chronological mRNA expression during neural stem cell differentiation without the use of transgenetic manipulation. The dynamic imaging montage of mRNA expression ultimately facilitated genetic heterogeneity analysis. In vivo lateral ventricle injection of this nanocomplex enabled endogenous neural stem cell activation and labeling at their specific differentiation stages. This nanocomplex is highly amenable as an alternative tool to explore the dynamics of intricate mRNA activities in various physiological and pathological conditions.

  16. Fully chip-embedded automation of a multi-step lab-on-a-chip process using a modularized timer circuit.

    PubMed

    Kang, Junsu; Lee, Donghyeon; Heo, Young Jin; Chung, Wan Kyun

    2017-11-07

    For highly-integrated microfluidic systems, an actuation system is necessary to control the flow; however, the bulk of actuation devices including pumps or valves has impeded the broad application of integrated microfluidic systems. Here, we suggest a microfluidic process control method based on built-in microfluidic circuits. The circuit is composed of a fluidic timer circuit and a pneumatic logic circuit. The fluidic timer circuit is a serial connection of modularized timer units, which sequentially pass high pressure to the pneumatic logic circuit. The pneumatic logic circuit is a NOR gate array designed to control the liquid-controlling process. By using the timer circuit as a built-in signal generator, multi-step processes could be done totally inside the microchip without any external controller. The timer circuit uses only two valves per unit, and the number of process steps can be extended without limitation by adding timer units. As a demonstration, an automation chip has been designed for a six-step droplet treatment, which entails 1) loading, 2) separation, 3) reagent injection, 4) incubation, 5) clearing and 6) unloading. Each process was successfully performed for a pre-defined step-time without any external control device.

  17. Constrained optimization of sequentially generated entangled multiqubit states

    NASA Astrophysics Data System (ADS)

    Saberi, Hamed; Weichselbaum, Andreas; Lamata, Lucas; Pérez-García, David; von Delft, Jan; Solano, Enrique

    2009-08-01

    We demonstrate how the matrix-product state formalism provides a flexible structure to solve the constrained optimization problem associated with the sequential generation of entangled multiqubit states under experimental restrictions. We consider a realistic scenario in which an ancillary system with a limited number of levels performs restricted sequential interactions with qubits in a row. The proposed method relies on a suitable local optimization procedure, yielding an efficient recipe for the realistic and approximate sequential generation of any entangled multiqubit state. We give paradigmatic examples that may be of interest for theoretical and experimental developments.

  18. Sequential Events Control System (SECS) Overview

    NASA Technical Reports Server (NTRS)

    Interbartolo, Michael

    2009-01-01

    This slide presentation will cover the Sequential Events Control System (SECS), which is the Apollo spacecraft subsystem that controls the automatically sequenced functions during the mission and during any a borts that could be performed. Included in this presentation are its general architecture, its integration into and use of the spacecraft' s other systems, and details on the functions it is responsible for c ontrolling during the mission. The objectives are to describe the system's architecture, the major components in the system, and the major system functions.

  19. Highly selective micro-sequential injection lab-on-valve (muSI-LOV) method for the determination of ultra-trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometry.

    PubMed

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard; Hansen, Elo Harald

    2006-10-01

    A highly selective procedure is proposed for the determination of ultra-trace level concentrations of nickel in saline aqueous matrices exploiting a micro-sequential injection Lab-On-Valve (muSI-LOV) sample pretreatment protocol comprising bead injection separation/pre-concentration and detection by electrothermal atomic absorption spectrometry (ETAAS). Based on the dimethylglyoxime (DMG) reaction used for nickel analysis, the sample, as contained in a pH 9.0 buffer, is, after on-line merging with the chelating reagent, transported to a reaction coil attached to one of the external ports of the LOV to assure sufficient reaction time for the formation of Ni(DMG)(2) chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio of hydrophilic and lipophilic monomers. Following elution by a 50-muL methanol plug in an air-segmented modality, the nickel is finally quantified by ETAAS. Under the optimized conditions and for a sample volume of 1.8 mL, a retention efficiency of 70 % and an enrichment factor of 25 were obtained. The proposed methodology showed a high tolerance to the commonly encountered alkaline earth matrix elements in environmental waters, that is, calcium and magnesium, and was successfully applied for the determination of nickel in an NIST standard reference material (NIST 1640-Trace elements in natural water), household tap water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6 %. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05.

  20. Development of a dynamic coupled hydro-geomechanical code and its application to induced seismicity

    NASA Astrophysics Data System (ADS)

    Miah, Md Mamun

    This research describes the importance of a hydro-geomechanical coupling in the geologic sub-surface environment from fluid injection at geothermal plants, large-scale geological CO2 sequestration for climate mitigation, enhanced oil recovery, and hydraulic fracturing during wells construction in the oil and gas industries. A sequential computational code is developed to capture the multiphysics interaction behavior by linking a flow simulation code TOUGH2 and a geomechanics modeling code PyLith. Numerical formulation of each code is discussed to demonstrate their modeling capabilities. The computational framework involves sequential coupling, and solution of two sub-problems- fluid flow through fractured and porous media and reservoir geomechanics. For each time step of flow calculation, pressure field is passed to the geomechanics code to compute effective stress field and fault slips. A simplified permeability model is implemented in the code that accounts for the permeability of porous and saturated rocks subject to confining stresses. The accuracy of the TOUGH-PyLith coupled simulator is tested by simulating Terzaghi's 1D consolidation problem. The modeling capability of coupled poroelasticity is validated by benchmarking it against Mandel's problem. The code is used to simulate both quasi-static and dynamic earthquake nucleation and slip distribution on a fault from the combined effect of far field tectonic loading and fluid injection by using an appropriate fault constitutive friction model. Results from the quasi-static induced earthquake simulations show a delayed response in earthquake nucleation. This is attributed to the increased total stress in the domain and not accounting for pressure on the fault. However, this issue is resolved in the final chapter in simulating a single event earthquake dynamic rupture. Simulation results show that fluid pressure has a positive effect on slip nucleation and subsequent crack propagation. This is confirmed by running a sensitivity analysis that shows an increase in injection well distance results in delayed slip nucleation and rupture propagation on the fault.

  1. Determination of picloram in natural waters employing sequential injection square wave voltammetry using the hanging mercury drop electrode.

    PubMed

    Dos Santos, Luciana B O; Masini, Jorge C

    2007-05-15

    This paper describes the development of a sequential injection analysis method to automate the determination of picloram by square wave voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. To perform these tasks, an 800muL monosegment is formed, composed by 400muL of sample and 400muL of conditioning/standard solution, in medium of 0.10molL(-1) H(2)SO(4). Homogenization of the monosegment is achieved by three flow reversals. After homogenization the mixture zone is injected toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode, at a flow rate of 50muLs(-1). After a suitable delay time, the potential is scanned from -0.5 to -1.0V versus Ag/AgCl at frequency of 300Hz and pulse height of 25mV. The linear dynamic range is observed for picloram concentrations between 0.10 and 2.50mgL(-1) fitting to the linear equation I(p)=(-2.19+/-0.03)C(picloram)+(0.096+/-0.039), with R(2)=0.9996, for which the slope is given in muALmg(-1). The detection and quantification limits are 0.036 and 0.12mgL(-1), respectively. The sampling frequency is 37h(-1) when the standard addition protocol is followed, but can be increased to 41h(-1) if the protocol to obtain in-line external calibration curve is used for quantification. The method was applied for determination of picloram in spiked water samples and the accuracy was evaluated by comparison with high performance liquid chromatography using molecular absorption at 220nm for detection. No evidences of statistically significant differences between the two methods were observed.

  2. TDRSS-user orbit determination using batch least-squares and sequential methods

    NASA Astrophysics Data System (ADS)

    Oza, D. H.; Jones, T. L.; Hakimi, M.; Samii, Mina V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    1993-02-01

    The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), and operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were less than 40 meters after the filter had reached steady state.

  3. TDRSS-user orbit determination using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Hakimi, M.; Samii, Mina V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    1993-01-01

    The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), and operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were less than 40 meters after the filter had reached steady state.

  4. On the Use of Adaptive Instructional Images Based on the Sequential-Global Dimension of the Felder-Silverman Learning Style Theory

    ERIC Educational Resources Information Center

    Filippidis, Stavros K.; Tsoukalas, Ioannis A.

    2009-01-01

    An adaptive educational system that uses adaptive presentation is presented. In this system fragments of different images present the same content and the system can choose the one most relevant to the user based on the sequential-global dimension of Felder-Silverman's learning style theory. In order to retrieve the learning style of each student…

  5. Rheological study of copper and copper grapheme feedstock for powder injection molding

    NASA Astrophysics Data System (ADS)

    Azaman, N. Emira Binti; Rafi Raza, M.; Muhamad, N.; Niaz Akhtar, M.; Bakar Sulong, A.

    2017-01-01

    Heatsink is one of the solution to optimize the performance of smart electronic devices. Copper and its composites are helping the electronic industry to solve the heating problem. Copper-graphene heat sink material with enhanced thermal conductivity is the ultimate goal.Powder injection molding (PIM) has advantages of high precision and production rate, complex shape, low cost and suitabality for metal and cremics.PIM consists of four sub sequential steps; feedstock preparation, molding, debinding and sintering. Feedstock preparation is a critical step in PIM process. Any deficiency at this stage cannot be recovered at latter stages. Therefore, this research was carried out to investigate the injectability of copper and copper graphene composite using PIM. PEG based multicomponent binder system was used and the powder loading was upto 7vol.% less than the critical powder loading was used to provide the wettability of the copper powder and graphene nanoplatelets (GNps). Corpper-graphene feedstock contained 0.5vol.% of GNps . To ensure the homogeneity of GNps within feedstock a unique technique was addopted. The microscopic results showed that the feedstock is homogeneous and ready for injection. The viscosity-shear rate relationship was determined and results showed that the addition of 0.5vol.% of GNps in copper has increased the viscosity upto 64.9% at 140˚C than that of pure copper feedstock. This attribute may be due to the large surface area of GNps. On the other hand, by increasing the temperature, viscosity of the feedstock was decreased, which was recommended for PIM. The overall viscosity and share rate lies within the range recommended for PIM process. It is clear that both feedstocks showed pseudo plastic behaviour which is suitable for PIM process. In the pseudo plastic behaviour, the viscosity decreases with the shear rate. It may be due to change in the structure of the solid particles or the binder. The molding results showed that both copper feedstocks were successfully molded and free from the physical defects.

  6. [Response of Calliphora vicina larval hemocytes to abiotic and biotic foreign particles injection].

    PubMed

    Kind, T V

    2012-01-01

    Human erythrocytes injection into the body cavity of Calliphora vicina postfeeding larvae results to their fast binding by thrombocytoidal fragments with agglutinates formation. There were almost none sites of lysis and degradation of erythrocytes in agglutinates even after shape modification and strands generation. Exceptions are zones of agglutinates with juvenile hemocytes, where destruction of erythrocytes is seen. The sequential injection of erythrocytes and charcoal particles leads to charcoal adhesion at first to agglutinates periphery and later to more deep stratum of cytoplasm between the erythrocytes. Under such conditions agglutinate formation period is accompanied with morphology variations which do not influence the intensity of agglutinating reaction. Juvenile plasmatocytes phagocytized the charcoal particles regardless of their concentration and duration of previous contact with erythrocytes. When mixture of abiotic and biotic particles was injected into post feeding larvae, crythrocytes and charcoal generate independent aggregations in the range of separate agglutinates. At the same time plasmatocytes form nodules consisting of temporary cell aggregations covered with cores of non phagocytized charcoal particles. These data testified that presumably lectin receptors responsible for foreign biotic and abiotic particles recognition are very near but not identical for different types of hemocytes. They may be specifical (for plasmatocytes) or integrated to different parts of cellular membrane (in thrombocytoids).

  7. Maximizing the value of pressure data in saline aquifer characterization

    NASA Astrophysics Data System (ADS)

    Yoon, Seonkyoo; Williams, John R.; Juanes, Ruben; Kang, Peter K.

    2017-11-01

    The injection and storage of freshwater in saline aquifers for the purpose of managed aquifer recharge is an important technology that can help ensure sustainable water resources. As a result of the density difference between the injected freshwater and ambient saline groundwater, the pressure field is coupled to the spatial salinity distribution, and therefore experiences transient changes. The effect of variable density can be quantified by the mixed convection ratio, which is a ratio between the strength of two convection processes: free convection due to the density differences and forced convection due to hydraulic gradients. We combine a density-dependent flow and transport simulator with an ensemble Kalman filter (EnKF) to analyze the effects of freshwater injection rates on the value-of-information of transient pressure data for saline aquifer characterization. The EnKF is applied to sequentially estimate heterogeneous aquifer permeability fields using real-time pressure data. The performance of the permeability estimation is analyzed in terms of the accuracy and the uncertainty of the estimated permeability fields as well as the predictability of breakthrough curve arrival times in a realistic push-pull setting. This study demonstrates that injecting fluids at a rate that balances the two characteristic convections can maximize the value of pressure data for saline aquifer characterization.

  8. Four-channel surface coil array for sequential CW-EPR image acquisition

    NASA Astrophysics Data System (ADS)

    Enomoto, Ayano; Emoto, Miho; Fujii, Hirotada; Hirata, Hiroshi

    2013-09-01

    This article describes a four-channel surface coil array to increase the area of visualization for continuous-wave electron paramagnetic resonance (CW-EPR) imaging. A 776-MHz surface coil array was constructed with four independent surface coil resonators and three kinds of switches. Control circuits for switching the resonators were also built to sequentially perform EPR image acquisition for each resonator. The resonance frequencies of the resonators were shifted using PIN diode switches to decouple the inductively coupled coils. To investigate the area of visualization with the surface coil array, three-dimensional EPR imaging was performed using a glass cell phantom filled with a solution of nitroxyl radicals. The area of visualization obtained with the surface coil array was increased approximately 3.5-fold in comparison to that with a single surface coil resonator. Furthermore, to demonstrate the applicability of this surface coil array to animal imaging, three-dimensional EPR imaging was performed in a living mouse with an exogenously injected nitroxyl radical imaging agent.

  9. Monitoring proteins using in vivo near-infrared time-domain optical imaging after 2-O-hexyldiglycerol-mediated transfer to the brain.

    PubMed

    Hülper, Petra; Dullin, Christian; Kugler, Wilfried; Lakomek, Max; Erdlenbruch, Bernhard

    2011-04-01

    The aim of the present study was to gain insight into the penetration, biodistribution, and fate of globulins in the brain after 2-O-hexyldiglycerol-induced blood-brain barrier opening. The spatial distribution of fluorescence probes was investigated after blood-brain barrier opening with intracarotid 2-O-hexyldiglycerol injection. Fluorescence intensity was visualized by microscopy (mice and rats) and by in vivo time-domain optical imaging. There was an increased 2-O-hexyldiglycerol-mediated transfer of fluorescence-labeled globulins into the ipsilateral hemisphere. Sequential in vivo measurements revealed that the increase in protein concentration lasted at least 96 h after administration. Ex vivo detection of tissue fluorescence confirmed the results obtained in vivo. Globulins enter the healthy brain in conjunction with 2-O-hexyldiglycerol. Sequential in vivo near-infrared fluorescence measurements enable the visualization of the spatial distribution of antibodies in the brain of living small animals.

  10. Use of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS) for Sequential Multi-Element Determination of Metals in Seawater and Wastewater Samples

    NASA Astrophysics Data System (ADS)

    Peña-Vázquez, E.; Barciela-Alonso, M. C.; Pita-Calvo, C.; Domínguez-González, R.; Bermejo-Barrera, P.

    2015-09-01

    The objective of this work is to develop a method for the determination of metals in saline matrices using high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Module SFS 6 for sample injection was used in the manual mode, and flame operating conditions were selected. The main absorption lines were used for all the elements, and the number of selected analytical pixels were 5 (CP±2) for Cd, Cu, Fe, Ni, Pb and Zn, and 3 pixels for Mn (CP±1). Samples were acidified (0.5% (v/v) nitric acid), and the standard addition method was used for the sequential determination of the analytes in diluted samples (1:2). The method showed good precision (RSD(%) < 4%, except for Pb (6.5%)) and good recoveries. Accuracy was checked after the analysis of an SPS-WW2 wastewater reference material diluted with synthetic seawater (dilution 1:2), showing a good agreement between certified and experimental results.

  11. Simultaneous and Sequential MS/MS Scan Combinations and Permutations in a Linear Quadrupole Ion Trap.

    PubMed

    Snyder, Dalton T; Szalwinski, Lucas J; Cooks, R Graham

    2017-10-17

    Methods of performing precursor ion scans as well as neutral loss scans in a single linear quadrupole ion trap have recently been described. In this paper we report methodology for performing permutations of MS/MS scan modes, that is, ordered combinations of precursor, product, and neutral loss scans following a single ion injection event. Only particular permutations are allowed; the sequences demonstrated here are (1) multiple precursor ion scans, (2) precursor ion scans followed by a single neutral loss scan, (3) precursor ion scans followed by product ion scans, and (4) segmented neutral loss scans. (5) The common product ion scan can be performed earlier in these sequences, under certain conditions. Simultaneous scans can also be performed. These include multiple precursor ion scans, precursor ion scans with an accompanying neutral loss scan, and multiple neutral loss scans. We argue that the new capability to perform complex simultaneous and sequential MS n operations on single ion populations represents a significant step in increasing the selectivity of mass spectrometry.

  12. Markovian Analysis of the Sequential Behavior of the Spontaneous Spinal Cord Dorsum Potentials Induced by Acute Nociceptive Stimulation in the Anesthetized Cat.

    PubMed

    Martin, Mario; Béjar, Javier; Esposito, Gennaro; Chávez, Diógenes; Contreras-Hernández, Enrique; Glusman, Silvio; Cortés, Ulises; Rudomín, Pablo

    2017-01-01

    In a previous study we developed a Machine Learning procedure for the automatic identification and classification of spontaneous cord dorsum potentials ( CDPs ). This study further supported the proposal that in the anesthetized cat, the spontaneous CDPs recorded from different lumbar spinal segments are generated by a distributed network of dorsal horn neurons with structured (non-random) patterns of functional connectivity and that these configurations can be changed to other non-random and stable configurations after the noceptive stimulation produced by the intradermic injection of capsaicin in the anesthetized cat. Here we present a study showing that the sequence of identified forms of the spontaneous CDPs follows a Markov chain of at least order one. That is, the system has memory in the sense that the spontaneous activation of dorsal horn neuronal ensembles producing the CDPs is not independent of the most recent activity. We used this markovian property to build a procedure to identify portions of signals as belonging to a specific functional state of connectivity among the neuronal networks involved in the generation of the CDPs . We have tested this procedure during acute nociceptive stimulation produced by the intradermic injection of capsaicin in intact as well as spinalized preparations. Altogether, our results indicate that CDP sequences cannot be generated by a renewal stochastic process. Moreover, it is possible to describe some functional features of activity in the cord dorsum by modeling the CDP sequences as generated by a Markov order one stochastic process. Finally, these Markov models make possible to determine the functional state which produced a CDP sequence. The proposed identification procedures appear to be useful for the analysis of the sequential behavior of the ongoing CDPs recorded from different spinal segments in response to a variety of experimental procedures including the changes produced by acute nociceptive stimulation. They are envisaged as a useful tool to examine alterations of the patterns of functional connectivity between dorsal horn neurons under normal and different pathological conditions, an issue of potential clinical concern.

  13. Three-dimensional rotational angiography fused with multimodal imaging modalities for targeted endomyocardial injections in the ischaemic heart.

    PubMed

    Dauwe, Dieter Frans; Nuyens, Dieter; De Buck, Stijn; Claus, Piet; Gheysens, Olivier; Koole, Michel; Coudyzer, Walter; Vanden Driessche, Nina; Janssens, Laurens; Ector, Joris; Dymarkowski, Steven; Bogaert, Jan; Heidbuchel, Hein; Janssens, Stefan

    2014-08-01

    Biological therapies for ischaemic heart disease require efficient, safe, and affordable intramyocardial delivery. Integration of multiple imaging modalities within the fluoroscopy framework can provide valuable information to guide these procedures. We compared an anatomo-electric method (LARCA) with a non-fluoroscopic electromechanical mapping system (NOGA(®)). LARCA integrates selective three-dimensional-rotational angiograms with biplane fluoroscopy. To identify the infarct region, we studied LARCA-fusion with pre-procedural magnetic resonance imaging (MRI), dedicated CT, or (18)F-FDG-PET/CT. We induced myocardial infarction in 20 pigs by 90-min LAD occlusion. Six weeks later, we compared peri-infarct delivery accuracy of coloured fluospheres using sequential NOGA(®)- and LARCA-MRI-guided vs. LARCA-CT- and LARCA-(18)F-FDG-PET/CT-guided intramyocardial injections. MRI after 6 weeks revealed significant left ventricular (LV) functional impairment and remodelling (LVEF 31 ± 3%, LVEDV 178 ± 15 mL, infarct size 17 ± 2% LV mass). During NOGA(®)-procedures, three of five animals required DC-shock for major ventricular arrhythmias vs. one of ten during LARCA-procedures. Online procedure time was shorter for LARCA than NOGA(®) (77 ± 6 vs. 130 ± 3 min, P < 0.0001). Absolute distance of injection spots to the infarct border was similar for LARCA-MRI (4.8 ± 0.5 mm) and NOGA(®) (5.4 ± 0.5 mm). LARCA-CT-integration allowed closer approximation of the targeted border zone than LARCA-PET (4.0 ± 0.5 mm vs. 6.2 ± 0.6 mm, P < 0.05). Three-dimensional -rotational angiography fused with multimodal imaging offers a new, cost-effective, and safe strategy to guide intramyocardial injections. Endoventricular procedure times and arrhythmias compare favourably to NOGA(®), without compromising injection accuracy. LARCA-based fusion imaging is a promising enabling technology for cardiac biological therapies. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  14. Distributed Immune Systems for Wireless Network Information Assurance

    DTIC Science & Technology

    2010-04-26

    ratio test (SPRT), where the goal is to optimize a hypothesis testing problem given a trade-off between the probability of errors and the...using cumulative sum (CUSUM) and Girshik-Rubin-Shiryaev (GRSh) statistics. In sequential versions of the problem the sequential probability ratio ...the more complicated problems, in particular those where no clear mean can be established. We developed algorithms based on the sequential probability

  15. Intratympanic Iodine Contrast Injection Diffuses Across the Round Window Membrane Allowing for Perilymphatic CT Volume Acquisition Imaging

    PubMed Central

    Abt, Nicholas B.; Lehar, Mohamed; Guajardo, Carolina Trevino; Penninger, Richard T.; Ward, Bryan K.; Pearl, Monica S.; Carey, John P.

    2016-01-01

    Hypothesis Whether the RWM is permeable to iodine-based contrast agents (IBCA) is unknown; therefore, our goal was to determine if IBCAs could diffuse through the RWM using CT volume acquisition imaging. Introduction Imaging of hydrops in the living human ear has attracted recent interest. Intratympanic (IT) injection has shown gadolinium's ability to diffuse through the round window membrane (RWM), enhancing the perilymphatic space. Methods Four unfixed human cadaver temporal bones underwent intratympanic IBCA injection using three sequentially studied methods. The first method was direct IT injection. The second method used direct RWM visualization via tympanomeatal flap for IBCA-soaked absorbable gelatin pledget placement. In the third method, the middle ear was filled with contrast after flap elevation. Volume acquisition CT images were obtained immediately post-exposure, and at 1, 6, and 24 hour intervals. Post-processing was accomplished using color ramping and subtraction imaging. Results Following the third method, positive RWM and perilymphatic enhancement were seen with endolymph sparing. Gray scale and color ramp multiplanar reconstructions displayed increased signal within the cochlea compared to pre-contrast imaging. The cochlea was measured for attenuation differences compared to pure water, revealing a pre-injection average of −1,103 HU and a post-injection average of 338 HU. Subtraction imaging shows enhancement remaining within the cochlear space, Eustachian tube, middle ear epithelial lining, and mastoid. Conclusions Iohexol iodine contrast is able to diffuse across the RWM. Volume acquisition CT imaging was able to detect perilymphatic enhancement at 0.5mm slice thickness. The clinical application of IBCA IT injection appears promising but requires further safety studies. PMID:26859543

  16. Increase of heat-shock protein and induction of gamma/delta T cells in peritoneal exudate of mice after injection of live Fusobacterium nucleatum.

    PubMed Central

    Saito, K; Katsuragi, H; Mikami, M; Kato, C; Miyamaru, M; Nagaso, K

    1997-01-01

    Fusobacterium nucleatum and Actinobacillus actinomycetemcomitans are Gram-negative rod periodontal pathogens. The peritoneal cavity of Institute of Cancer Research (ICR) mice was used as the local infection model. In vivo production of heat-shock proteins (hsp) was studied by injection of 1/10 minimum lethal dose (MLD) of each live bacteria into mice. Heat-shock proteins 70 and 60 were examined in the extract of peritoneal exudate cells (PEC) from mice injected intraperitoneally with either F. nucleatum or A. actinomycetemcomitans by using sodium dodecylsulphate-polyacrylamide gel electrophoresis and immunoblotting analysis. Although hsp are present in PEC without injection of the bacteria, both hsp increased and reached a peak on day 3 after F. nucleatum injection but not after A. actinomycetemcomitans. Kinetic study of gamma/delta cells in PEC after injection of bacteria showed that the increase of gamma/delta T cells was observed only in the PEC from mice injected with F. nucleatum but not A. actinomycetemcomitans. The gamma/delta T cells in PEC were either CD3+ and CD4+ or CD3+ and CD8+. The differential cell count of PEC suggested that gamma/delta T-cell induction is related to the expansion of the macrophage population. The phagocytic and chemiluminescence responses of macrophages against the same bacteria were compared after intensive immunization with live F. nucleatum and A. actinomycetemcomitans. Elevations of chemiluminescence response and phagocytic function by immunization were observed in the macrophages of mice immunized with F. nucleatum. These results suggest the sequential appearance of hsp, gamma/delta T cells and macrophage activation after fusobacterial infection. Images Figure 2 PMID:9135551

  17. High-resolution Observations of Flares in an Arch Filament System

    NASA Astrophysics Data System (ADS)

    Su, Yingna; Liu, Rui; Li, Shangwei; Cao, Wenda; Ahn, Kwangsu; Ji, Haisheng

    2018-03-01

    We study five sequential solar flares (SOL2015-08-07) occurring in Active Region 12396 observed with the Goode Solar Telescope (GST) at the Big Bear Solar Observatory, complemented by Interface Region Imaging Spectrograph and SDO observations. The main flaring region is an arch filament system (AFS) consisting of multiple bundles of dark filament threads enclosed by semicircular flare ribbons. We study the magnetic configuration and evolution of the active region by constructing coronal magnetic field models based on SDO/HMI magnetograms using two independent methods, i.e., the nonlinear force-free field (NLFFF) extrapolation and the flux rope insertion method. The models consist of multiple flux ropes with mixed signs of helicity, i.e., positive (negative) in the northern (southern) region, which is consistent with the GST observations of multiple filament bundles. The footprints of quasi-separatrix layers (QSLs) derived from the extrapolated NLFFF compare favorably with the observed flare ribbons. An interesting double-ribbon fine structure located at the east border of the AFS is consistent with the fine structure of the QSL’s footprint. Moreover, magnetic field lines traced along the semicircular footprint of a dome-like QSL surrounding the AFS are connected to the regions of significant helicity and Poynting flux injection. The maps of magnetic twist show that positive twist became dominant as time progressed, which is consistent with the injection of positive helicity before the flares. We hence conclude that these circular shaped flares are caused by 3D magnetic reconnection at the QSLs associated with the AFS possessing mixed signs of helicity.

  18. Field Demonstration of Sequential Iron Reduction and Aerobic Biodegradation of Nitrobenzene and 2,4-Dinitrotoluene

    NASA Astrophysics Data System (ADS)

    Robinson, T. L.; Gillham, R. W.; Gui, L.

    2005-12-01

    To demonstrate the in situ sequential degradation of nitrobenzene (NB) and 2,4-dinitrotoluene (2,4-DNT) using a granular iron permeable reactive barrier (PRB) and aerobic biodegradation zone, a field study is currently being conducted in a 24m long x 2m wide x 3m deep isolated section of the Borden aquifer (the ``gate''). This gate is closed on three sides by sealable-joint sheet piling keyed into the aquitard, and open to groundwater flow on the other, which, under natural conditions, is approximately parallel to the longest sides of the gate. The PRB was installed approximately 10 meters into the gate, and the oxygen injection system was installed approximately 18 meters into the gate. A hydraulic gradient was induced across the gate by pumping at the closed end via a fully-screened well, resulting in a groundwater velocity of 40-50 cm/day. Based on the results of laboratory tests, the first stage of the treatment system, involving the PRB, was expected to reduce nitrobenzene and 2,4-DNT to aniline and 2,4-diaminotoluene (2,4-DAT), respectively. Initial results show that portions of the nitrobenzene and 2,4-dinitrotoluene were transforming into their daughter products, aniline and 2,4-diaminotoluene, prior to the groundwater entering the permeable reactive barrier. Lab tests are ongoing to determine whether an indigenous bacterial population is capable of biotically transforming the nitro groups on the nitrobenzene and 2,4-DNT. In the second stage of the treatment system, oxygen was introduced via 4 10-inch diameter fully-screened wells spanning the width of the gate, each containing a Waterloo EmitterTM. The oxygen is expected to stimulate indigenous aerobic microbes in the aquifer to mineralize the aniline and 2,4-diaminotoluene, and the results from this are expected in the next few months.

  19. Development of the precerebellar nuclei in the rat: IV. The anterior precerebellar extramural migratory stream and the nucleus reticularis tegmenti pontis and the basal pontine gray.

    PubMed

    Altman, J; Bayer, S A

    1987-03-22

    Sequential thymidine radiograms from rats injected on days E16, E17, E18, and E19 and killed 2 hours after injection and at daily intervals up to day E22 were used to establish the site of origin, migratory route, and settling patterns of neurons of the nucleus reticularis tegmenti pontis and basal pontine gray. The nucleus reticularis tegmenti pontis neurons, which are produced predominantly on days E15 and E16, derive from the primary precerebellar neuroepithelium. These cells, unlike those of the lateral reticular and external cuneate nuclei, take an anteroventral subpial route, forming the anterior precerebellar extramural migratory stream. This migratory stream reaches the anterior pole of the pons by day E18. In rats injected on day E16 and killed on day E18 some of the cells that reach the pons are unlabeled, indicating that they represent the early component of neurons generated on day E15. The cells labeled on day E16 begin to settle in the pons on day E19, 3 days after their production. These cells, migrating in an orderly temporal sequence, form a posterodorsal-to-anteroventral gradient in the nucleus reticularis tegmenti pontis. Unlike the neurons of all the other precerebellar nuclei, the basal pontine gray neurons derive from the secondary precerebellar neuroepithelium. The secondary precerebellar neuroepithelium forms on day E16 as an outgrowth of the primary precerebellar neuroepithelium, and it remains mitotically active through day E19, spanning the entire period of basal pontine gray neurogenesis. The secondary precerebellar neuroepithelium is surrounded by a horizontal layer of postmitotic cells, representing the head-waters of the anterior precerebellar extramural migratory stream. In rats injected on day E18 and killed on day E19 the cells are labeled in the proximal half of the stream around the medulla but those closer to the pons are unlabeled, indicating an orderly sequence of migration. In rats injected on day E18 and killed on day E20 the labeled cells reach the pole of the pons. In the basal pontine gray the sequentially generated neurons settle in a precise order. The neurons generated on day E16 form a small core posteriorly and the neurons generated on days E17, E18, and E19 form regular concentric rings around the core in an inside-out sequence.

  20. Emergence of methadone as a street drug in St. Petersburg, Russia.

    PubMed

    Heimer, Robert; Lyubimova, Aleksandra; Barbour, Russell; Levina, Olga S

    2016-01-01

    The syndemic of opioid addiction, HIV, hepatitis, tuberculosis, imprisonment, and overdose in Russia has been worsened by the illegality of opioid substitution therapy. As part of on-going serial studies, we sought to explore the influence of opioid availability on aspects of the syndemic as it has affected the city of St. Petersburg. We employed a sequential approach in which quantitative data collection and statistical analysis were followed by a qualitative phase. Quantitative data were obtained in 2013-2014 from a respondent-driven sample (RDS) of people who inject drugs (PWID). Individuals recruited by RDS were tested for antibodies to HIV and interviewed about drug use and injection practices, sociodemographics, health status, and access to medical care. Subsequently, we collected in-depth qualitative data on methadone use, knowledge, and market availability from PWID recruited at nine different locations within St. Petersburg. Analysis of interview data from the sample revealed the percentage of PWID injecting methadone in the 30 days prior to interview increased from 3.6% in 2010 to 53.3% in 2012-2013. Injection of only methadone, as compared to injecting only heroin or both drugs, was associated with less frequent injection and reduced HIV-related injected risk, especially a lower rate of injecting with a previously used syringe. In-depth questioning of methadone injectors corroborated the finding from serial quantitative surveys of PWID that methadone's black market availability is a recent phenomenon. Spatial analysis revealed widespread methadone availability but no concentration in any specific districts of the city. Despite the prohibition of substitution therapy and demonization of methadone, the drug has emerged to rival heroin as the most commonly available opioid in St. Petersburg. Ironically, its use is associated with reduced injection-related HIV risk even when its use is illegal. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Emergence of Methadone as a Street Drug in St. Petersburg, Russia

    PubMed Central

    Heimer, Robert; Lyubimova, Aleksandra; Barbour, Russell; Levina, Olga S.

    2015-01-01

    Background The syndemic of opioid addiction, HIV, hepatitis, tuberculosis, imprisonment, and overdose in Russia has been worsened by the illegality of opioid substitution therapy. As part of on-going serial studies, we sought to explore the influence of opioid availability on aspects of the syndemic as it has affected the city of St. Petersburg. Methods We employed a sequential approach in which quantitative data collection and statistical analysis were followed by a qualitative phase. Quantitative data were obtained from a respondent-driven sample (RDS) of people who inject drugs (PWID) obtained in 2012–13. Individuals recruited by RDS were tested for antibodies to HIV and interviewed about drug use and injection practices, sociodemographics, health status, and access to medical care. Subsequently, we collected in-depth qualitative data on methadone use, knowledge, and market availability from PWID recruited at nine different locations within St. Petersburg. Results Analysis of interview data from the sample revealed he percentage of PWID injecting methadone in the 30 days prior to interview increased from 3.6% in 2010 to 53.3% in 2012–13. Injection of only methadone, as compared to injecting only heroin or both drugs, was associated with less frequent injection and reduced HIV-related injected risk, especially a lower rate of injecting with a previously used syringe. In-depth questioning of methadone injectors corroborated the finding from serial quantitative surveys of PWID that methadone’s black market availability is a recent phenomenon. Spatial analysis revealed widespread methadone availability but no concentration in any specific districts of the city. Conclusion Despite the prohibition of substitution therapy and demonization of methadone, the drug has emerged to rival heroin as the most commonly available opioid in St. Petersburg. Ironically, its use is associated with reduced injection-related HIV risk even when its use is illegal. PMID:26573380

  2. Factors influencing discomfort during anterior ultrasound-guided injection for hip arthrography.

    PubMed

    Hsu, Yi-Chih; Wu, Yu-Cheng; Kao, Hao-Lun; Pan, Ru-Yu; Lee, Meei-Shyuan; Huang, Guo-Shu

    2013-09-01

    Although ultrasound (US)-guided injection techniques for magnetic resonance arthrography of the hip have been used with increasing frequency to diagnose internal joint derangements, little is known about patient tolerance, which is relevant information for patients. The objective of this study was to evaluate prospectively the association between possible influencing factors and discomfort felt during the performance of anterior US-guided injection techniques targeting the femoral head-neck junction during hip arthrography. Forty-four consecutive patients (21 women and 23 men; mean age, 41 years) undergoing magnetic resonance hip arthrography were sequentially assigned to receive injection alternating between fixed and freehand US-guided injection. Discomfort was assessed using a visual analog scale and relative ratings. Patient body mass index, extra-articular contrast leakage, the duration of the procedure, the needle advancement distance, and the fixed trajectory of the needle were assessed. Pearson's correlation coefficients and multiple logistic regression analysis were used to determine the association. Puncture was successfully accomplished in all cases, and no relevant complications were reported. The only significant relationships were between discomfort and the time required for needle manipulation (r = 0.8) and fixed US-guided injection (r = 0.6; p < 0.001). Compared with the freehand technique, the fixed technique resulted in significantly less pain and took significantly less time to perform (p < 0.001). The procedure time during needle manipulation in the fixed US-guided injections (4.0 ± 0.9 seconds) was significantly less than that in the freehand US-guided injections (19.4 ± 17.6 seconds; p < 0.001). No significant relationships were found between discomfort and other parameters (r < 0.3, p > 0.05). The procedure time appears to be the most important factor influencing patient discomfort. Fixed US-guided injection is a time-saving technique that alleviates procedure-related discomfort. Copyright © 2013. Published by Elsevier B.V.

  3. Analyzing Communication Architectures Using Commercial Off-The-Shelf (COTS) Modeling and Simulation Tools

    DTIC Science & Technology

    1998-06-01

    4] By 2010, we should be able to change how we conduct the most intense joint operations. Instead of relying on massed forces and sequential ...not independent, sequential steps. Data probes to support the analysis phase were required to complete the logical models. This generated a need...Networks) Identify Granularity (System Level) - Establish Physical Bounds or Limits to Systems • Determine System Test Configuration and Lineup

  4. Comparison of ERBS orbit determination accuracy using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Fabien, S. M.; Mistretta, G. D.; Hart, R. C.; Doll, C. E.

    1991-01-01

    The Flight Dynamics Div. (FDD) at NASA-Goddard commissioned a study to develop the Real Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination of spacecraft on a DOS based personal computer (PC). An overview is presented of RTOD/E capabilities and the results are presented of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOS/E on a PC with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. RTOD/E was used to perform sequential orbit determination for the Earth Radiation Budget Satellite (ERBS), and the Goddard Trajectory Determination System (GTDS) was used to perform the batch least squares orbit determination. The estimated ERBS ephemerides were obtained for the Aug. 16 to 22, 1989, timeframe, during which intensive TDRSS tracking data for ERBS were available. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for ERBS; the solution differences were less than 40 meters after the filter had reached steady state.

  5. Comparison of ERBS orbit determination accuracy using batch least-squares and sequential methods

    NASA Astrophysics Data System (ADS)

    Oza, D. H.; Jones, T. L.; Fabien, S. M.; Mistretta, G. D.; Hart, R. C.; Doll, C. E.

    1991-10-01

    The Flight Dynamics Div. (FDD) at NASA-Goddard commissioned a study to develop the Real Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination of spacecraft on a DOS based personal computer (PC). An overview is presented of RTOD/E capabilities and the results are presented of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOS/E on a PC with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. RTOD/E was used to perform sequential orbit determination for the Earth Radiation Budget Satellite (ERBS), and the Goddard Trajectory Determination System (GTDS) was used to perform the batch least squares orbit determination. The estimated ERBS ephemerides were obtained for the Aug. 16 to 22, 1989, timeframe, during which intensive TDRSS tracking data for ERBS were available. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for ERBS; the solution differences were less than 40 meters after the filter had reached steady state.

  6. Evaluation of Silicone as an Artificial Lubricant in Osteoarthrotic Joints

    PubMed Central

    Wright, V.; Haslock, D. I.; Dowson, D.; Seller, P. C.; Reeves, B.

    1971-01-01

    Silicone 300 has been evaluated as an artificial lubricant in osteoarthrotic joints by means of a pilot study in five inpatients and a control trial of 25 outpatients with 40 osteoarthrotic knees. Sequential analysis showed a significant benefit from saline compared with silicone at one week follow-up and no significant difference at one month. Measurement of stiffness with a knee arthrograph showed no difference in reduction of stiffness between the two substances. In a study of 18 rabbits there was no evidence that silicone was retained in the joint cavity for longer than 48 hours. There was a failure of clearance of iodinated serum albumin for as long as three to four days after the injection of silicone, suggesting some obstruction to lymphatic outflow. Experimentally produced cartilaginous defects did not heal quicker with the injection of silicone into the joint. PMID:5575973

  7. Localized sequence-specific release of a chemopreventive agent and an anticancer drug in a time-controllable manner to enhance therapeutic efficacy.

    PubMed

    Pan, Wen-Yu; Lin, Kun-Ju; Huang, Chieh-Cheng; Chiang, Wei-Lun; Lin, Yu-Jung; Lin, Wei-Chih; Chuang, Er-Yuan; Chang, Yen; Sung, Hsing-Wen

    2016-09-01

    Combination chemotherapy with multiple drugs commonly requires several injections on various schedules, and the probability that the drug molecules reach the diseased tissues at the proper time and effective therapeutic concentrations is very low. This work elucidates an injectable co-delivery system that is based on cationic liposomes that are adsorbed on anionic hollow microspheres (Lipos-HMs) via electrostatic interaction, from which the localized sequence-specific release of a chemopreventive agent (1,25(OH)2D3) and an anticancer drug (doxorubicin; DOX) can be thermally driven in a time-controllable manner by an externally applied high-frequency magnetic field (HFMF). Lipos-HMs can greatly promote the accumulation of reactive oxygen species (ROS) in tumor cells by reducing their cytoplasmic expression of an antioxidant enzyme (superoxide dismutase) by 1,25(OH)2D3, increasing the susceptibility of cancer cells to the cytotoxic action of DOX. In nude mice that bear xenograft tumors, treatment with Lipos-HMs under exposure to HFMF effectively inhibits tumor growth and is the most effective therapeutic intervention among all the investigated. These empirical results demonstrate that the synergistic anticancer effects of sequential release of 1,25(OH)2D3 and DOX from the Lipos-HMs may have potential for maximizing DOX cytotoxicity, supporting more effective cancer treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Optimal sequential measurements for bipartite state discrimination

    NASA Astrophysics Data System (ADS)

    Croke, Sarah; Barnett, Stephen M.; Weir, Graeme

    2017-05-01

    State discrimination is a useful test problem with which to clarify the power and limitations of different classes of measurement. We consider the problem of discriminating between given states of a bipartite quantum system via sequential measurement of the subsystems, with classical feed-forward of measurement results. Our aim is to understand when sequential measurements, which are relatively easy to implement experimentally, perform as well, or almost as well, as optimal joint measurements, which are in general more technologically challenging. We construct conditions that the optimal sequential measurement must satisfy, analogous to the well-known Helstrom conditions for minimum error discrimination in the unrestricted case. We give several examples and compare the optimal probability of correctly identifying the state via global versus sequential measurement strategies.

  9. Establishment of a canine model of acute pulmonary embolism with definite right ventricular dysfunction through introduced autologous blood clots.

    PubMed

    Zhao, Lin-Bo; Jia, Zhen-Yu; Lu, Guang-Dong; Zhu, Yin-Su; Jing, Lei; Shi, Hai-Bin

    2015-04-01

    To establish a canine model of acute pulmonary embolism (PE) with right ventricular (RV) dysfunction using autologous blood clots and evaluate by echocardiography and contrast-enhanced Computed Tomography (CT). Autologous blood clots formed in vitro were introduced sequentially into the pulmonary arteries of eight healthy mixed-breed dogs while monitoring pulmonary and systemic hemodynamic function. Blood clots were injected until the mean pulmonary artery pressure (MPAP) reached two-three times the baseline pressure, which was maintained up to 1 hour. The RV function was assessed by echocardiography and ECG-gated dual-source contrast CT. All animals survived the imaging procedure. The post-injection pulmonary angiograms showed extensive PE, and MPAP increased from 16.50±2.45 mmHg to 43.13±4.91 mmHg (P<0.001). On echocardiography, the RV fractional area change decreased from 42.06±3.36 to 27.96±3.54 (P<0.001), and the RV myocardial performance increased from 0.20±0.05 to 0.63±0.16 (P<0.001). On CT, the RV end-systolic volume increased from 11.11±1.81 ml to 24.71±4.60 ml (P<0.001), RV end-diastolic volume from 20.73±2.83 ml to 34.63±5.76 ml (P<0.001), and the four-chamber RV/left ventricular diameter ratio from 0.38±0.07 to 0.81±0.14 (P<0.001). Acute PE with RV dysfunction was established in a large animal model through controlled injection of autologous blood clots, which may be useful for developing and evaluating new therapeutic approaches for acute PE with RV dysfunction. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Hospital's activity-based financing system and manager-physician [corrected] interaction.

    PubMed

    Crainich, David; Leleu, Hervé; Mauleon, Ana

    2011-10-01

    This paper examines the consequences of the introduction of an activity-based reimbursement system on the behavior of physicians and hospital's managers. We consider a private for-profit sector where both hospitals and physicians are initially paid on a fee-for-service basis. We show that the benefit of the introduction of an activity-based system depends on the type of interaction between managers and physicians (simultaneous or sequential decision-making games). It is shown that, under the activity-based system, a sequential interaction with physician leader could be beneficial for both agents in the private sector. We further model an endogenous timing game à la Hamilton and Slutsky (Games Econ Behav 2: 29-46, 1990) in which the type of interaction is determined endogenously. We show that, under the activity-based system, the sequential interaction with physician leader is the unique subgame perfect equilibrium.

  11. Status of the "new" AMS facility in Trondheim

    NASA Astrophysics Data System (ADS)

    Nadeau, Marie-Josée; Vaernes, Einar; Svarva, Helene Løvstrand; Larsen, Eiliv; Gulliksen, Steinar; Klein, Matthias; Mous, Dirk J. W.

    2015-10-01

    The Radiocarbon Laboratory of the Norwegian University of Science and Technology (NTNU) in Trondheim has a long history, dating back to the 1950s. Its relatively new AMS facility is based on a 1 MV Tandetron from High Voltage Engineering Europa B.V. that is equipped with a hybrid solid/gas SO-110 ion source, a low energy spectrometer supporting sequential injection, a high energy analysis system consisting of a magnet and an electrostatic deflector, allowing insertion of an absorber foil for isobar suppression, and a two dimensional gas ionisation detector (E and ΔE). The system is at present capable of measuring 10Be, 14C, and 26Al and can be easily modified to measure isotopes of higher masses. Acceptance tests results for 10Be1+, 14C2+, 26Al1+, and 26Al3+ are presented. The laboratory measures only 14C at present and the routine procedures are described. The system has demonstrated a very low background (70,000 14C years BP or 2·10-16 on Alfa Aesar 40795 graphite powder, -200 mesh, 99.9995%) for 14C when charge state 2+ is measured and the interference of Li ions in the detector is minimal. Some ion optical peculiarities of the system are also discussed.

  12. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    PubMed

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  13. Targeted Drug Delivery in the Suprachoroidal Space by Swollen Hydrogel Pushing

    PubMed Central

    Jung, Jae Hwan; Desit, Patcharin; Prausnitz, Mark R.

    2018-01-01

    Purpose The purpose is to target model drug particles to the posterior region of the suprachoroidal space (SCS) of the eye controlled via pushing by hydrogel swelling. Methods A particle formulation containing 1% hyaluronic acid (HA) with fluorescent polymer particles and a hydrogel formulation containing 4% HA were introduced in a single syringe as two layers without mixing, and injected sequentially into the SCS of the rabbit eye ex vivo and in vivo using a microneedle. Distribution of particles in the eye was determined by microscopy. Results During injection, the particle formulation was pushed toward the middle of the SCS by the viscous hydrogel formulation, but less than 12% of particles reached the posterior SCS. After injection, the particle formulation was pushed further toward the macula and optic nerve in the posterior SCS by hydrogel swelling and spreading. Heating the eye to 37°C, or injecting in vivo decreased viscosity and mechanical strength of the hydrogel, thereby allowing it to swell and flow further in the SCS. A high salt concentration (9% NaCl) in the hydrogel formulation further increased hydrogel swelling due to osmotic flow into the hydrogel. In this way, up to 76% of particles were delivered to the posterior SCS from an injection made near the limbus. Conclusions This study shows that model drug particles can be targeted to the posterior SCS by HA hydrogel swelling and pushing without particle functionalization or administering external driving forces. PMID:29677369

  14. In situ bioremediation of uranium with emulsified vegetable oil as the electron donor.

    PubMed

    Watson, David B; Wu, Wei-Min; Mehlhorn, Tonia; Tang, Guoping; Earles, Jennifer; Lowe, Kenneth; Gihring, Thomas M; Zhang, Gengxin; Phillips, Jana; Boyanov, Maxim I; Spalding, Brian P; Schadt, Christopher; Kemner, Kenneth M; Criddle, Craig S; Jardine, Philip M; Brooks, Scott C

    2013-06-18

    A field test with a one-time emulsified vegetable oil (EVO) injection was conducted to assess the capacity of EVO to sustain uranium bioreduction in a high-permeability gravel layer with groundwater concentrations of (mM) U, 0.0055; Ca, 2.98; NO3(-), 0.11; HCO3(-), 5.07; and SO4(2-), 1.23. Comparison of bromide and EVO migration and distribution indicated that a majority of the injected EVO was retained in the subsurface from the injection wells to 50 m downgradient. Nitrate, uranium, and sulfate were sequentially removed from the groundwater within 1-2 weeks, accompanied by an increase in acetate, Mn, Fe, and methane concentrations. Due to the slow release and degradation of EVO with time, reducing conditions were sustained for approximately one year, and daily U discharge to a creek, located approximately 50 m from the injection wells, decreased by 80% within 100 days. Total U discharge was reduced by 50% over the one-year period. Reduction of U(VI) to U(IV) was confirmed by synchrotron analysis of recovered aquifer solids. Oxidants (e.g., dissolved oxygen, nitrate) flowing in from upgradient appeared to reoxidize and remobilize uranium after the EVO was exhausted as evidenced by a transient increase of U concentration above ambient values. Occasional (e.g., annual) EVO injection into a permeable Ca and bicarbonate-containing aquifer can sustain uranium bioreduction/immobilization and decrease U migration/discharge.

  15. Microwave Ablation: Comparison of Simultaneous and Sequential Activation of Multiple Antennas in Liver Model Systems.

    PubMed

    Harari, Colin M; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T; Lubner, Meghan G; Hinshaw, J Louis; Ziemlewicz, Timothy; Brace, Christopher L

    2016-01-01

    To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P < .05). Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P < .05). Ablations were generally smaller in vivo compared with ex vivo. The use of multiple antennas and simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015.

  16. Anti-tumor activity of high-dose EGFR tyrosine kinase inhibitor and sequential docetaxel in wild type EGFR non-small cell lung cancer cell nude mouse xenografts

    PubMed Central

    Tang, Ning; Zhang, Qianqian; Fang, Shu; Han, Xiao; Wang, Zhehai

    2017-01-01

    Treatment of non-small-cell lung cancer (NSCLC) with wild-type epidermal growth factor receptor (EGFR) is still a challenge. This study explored antitumor activity of high-dose icotinib (an EGFR tyrosine kinase inhibitor) plus sequential docetaxel against wild-type EGFR NSCLC cells-generated nude mouse xenografts. Nude mice were subcutaneously injected with wild-type EGFR NSCLC A549 cells and divided into different groups for 3-week treatment. Tumor xenograft volumes were monitored and recorded, and at the end of experiments, tumor xenografts were removed for Western blot and immunohistochemical analyses. Compared to control groups (negative control, regular-dose icotinib [IcoR], high-dose icotinib [IcoH], and docetaxel [DTX]) and regular icotinib dose (60 mg/kg) with docetaxel, treatment of mice with a high-dose (1200 mg/kg) of icotinib plus sequential docetaxel for 3 weeks (IcoH-DTX) had an additive effect on suppression of tumor xenograft size and volume (P < 0.05). Icotinib-containing treatments markedly reduced phosphorylation of EGFR, mitogen activated protein kinase (MAPK), and protein kinase B (Akt), but only the high-dose icotinib-containing treatments showed an additive effect on CD34 inhibition (P < 0.05), an indication of reduced microvessel density in tumor xenografts. Moreover, high-dose icotinib plus docetaxel had a similar effect on mouse weight loss (a common way to measure adverse reactions in mice), compared to the other treatment combinations. The study indicate that the high dose of icotinib plus sequential docetaxel (IcoH-DTX) have an additive effect on suppressing the growth of wild-type EGFR NSCLC cell nude mouse xenografts, possibly through microvessel density reduction. Future clinical trials are needed to confirm the findings of this study. PMID:27852073

  17. ANAEROBIC AND AEROBIC TREATMENT OF CHLORINATED ALIPHATIC COMPOUNDS

    EPA Science Inventory

    Biological degradation of 12 chlorinated aliphatic compounds (CACs) was assessed in bench-top reactors and in serum bottle tests. Three continuously mixed daily batch-fed reactor systems were evaluated: anaerobic, aerobic, and sequential-anaerobic-aerobic (sequential). Glucose,...

  18. Physics-based, Bayesian sequential detection method and system for radioactive contraband

    DOEpatents

    Candy, James V; Axelrod, Michael C; Breitfeller, Eric F; Chambers, David H; Guidry, Brian L; Manatt, Douglas R; Meyer, Alan W; Sale, Kenneth E

    2014-03-18

    A distributed sequential method and system for detecting and identifying radioactive contraband from highly uncertain (noisy) low-count, radionuclide measurements, i.e. an event mode sequence (EMS), using a statistical approach based on Bayesian inference and physics-model-based signal processing based on the representation of a radionuclide as a monoenergetic decomposition of monoenergetic sources. For a given photon event of the EMS, the appropriate monoenergy processing channel is determined using a confidence interval condition-based discriminator for the energy amplitude and interarrival time and parameter estimates are used to update a measured probability density function estimate for a target radionuclide. A sequential likelihood ratio test is then used to determine one of two threshold conditions signifying that the EMS is either identified as the target radionuclide or not, and if not, then repeating the process for the next sequential photon event of the EMS until one of the two threshold conditions is satisfied.

  19. Ratio of sequential chromatograms for quantitative analysis and peak deconvolution: Application to standard addition method and process monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Synovec, R.E.; Johnson, E.L.; Bahowick, T.J.

    1990-08-01

    This paper describes a new technique for data analysis in chromatography, based on taking the point-by-point ratio of sequential chromatograms that have been base line corrected. This ratio chromatogram provides a robust means for the identification and the quantitation of analytes. In addition, the appearance of an interferent is made highly visible, even when it coelutes with desired analytes. For quantitative analysis, the region of the ratio chromatogram corresponding to the pure elution of an analyte is identified and is used to calculate a ratio value equal to the ratio of concentrations of the analyte in sequential injections. For themore » ratio value calculation, a variance-weighted average is used, which compensates for the varying signal-to-noise ratio. This ratio value, or equivalently the percent change in concentration, is the basis of a chromatographic standard addition method and an algorithm to monitor analyte concentration in a process stream. In the case of overlapped peaks, a spiking procedure is used to calculate both the original concentration of an analyte and its signal contribution to the original chromatogram. Thus, quantitation and curve resolution may be performed simultaneously, without peak modeling or curve fitting. These concepts are demonstrated by using data from ion chromatography, but the technique should be applicable to all chromatographic techniques.« less

  20. Expert system for online surveillance of nuclear reactor coolant pumps

    DOEpatents

    Gross, Kenny C.; Singer, Ralph M.; Humenik, Keith E.

    1993-01-01

    An expert system for online surveillance of nuclear reactor coolant pumps. This system provides a means for early detection of pump or sensor degradation. Degradation is determined through the use of a statistical analysis technique, sequential probability ratio test, applied to information from several sensors which are responsive to differing physical parameters. The results of sequential testing of the data provide the operator with an early warning of possible sensor or pump failure.

  1. Effects of Injected CO2 on Geomechanical Properties Due to Mineralogical Changes

    NASA Astrophysics Data System (ADS)

    Nguyen, B. N.; Hou, Z.; Bacon, D. H.; Murray, C. J.; White, J. A.

    2013-12-01

    Long-term injection and storage of CO2 in deep underground reservoirs may significantly modify the geomechanical behavior of rocks since CO2 can react with the constituent phases of reservoir rocks and modify their composition. This can lead to modifications of their geomechanical properties (i.e., elastic moduli, Biot's coefficients, and permeability). Modifications of rock geomechanical properties have important consequences as these directly control stress and strain distributions, affect conditions for fracture initiation and development and/or fault healing. This paper attempts to elucidate the geochemical effects of CO2 on geomechanical properties of typical reservoir rocks by means of numerical analyses using the STOMP-ABAQUS sequentially coupled simulator that includes the capability to handle geomechanics and the reactive transport of CO2 together with a module (EMTA) to compute the homogenized rock poroelastic properties as a function of composition changes. EMTA, a software module developed at PNNL, implements the standard and advanced Eshelby-Mori-Tanaka approaches to compute the thermoelastic properties of composite materials. In this work, EMTA will be implemented in the coupled STOMP-ABAQUS simulator as a user subroutine of ABAQUS and used to compute local elastic stiffness based on rock composition. Under the STOMP-ABAQUS approach, STOMP models are built to simulate aqueous and CO2 multiphase fluid flows, and relevant chemical reactions of pore fluids with minerals in the reservoirs. The ABAQUS models then read STOMP output data for cell center coordinates, gas pressures, aqueous pressures, temperatures, saturations, constituent volume fractions, as well as permeability and porosity that are affected by chemical reactions. These data are imported into ABAQUS meshes using a mapping procedure developed for the exchange of data between STOMP and ABAQUS. Constitutive models implemented in ABAQUS via user subroutines then compute stiffness, stresses, strains, pore pressure, permeability, porosity, and capillary pressure, and return updated permeability, porosity, and capillary pressure to STOMP at selected times. In preliminary work, the enhanced STOMP-ABAQUS sequentially coupled approach is validated and illustrated in an example analysis of a cylindrical rock specimen subjected to axial loading, confining pressure, and CO2 fluid injection. The geomechanical analysis accounting for CO2 reactions with rock constituents is compared to that without chemical reactions to elucidate the geochemical effects of injected CO2 on the response of the reservoir rock to stress.

  2. Treatment of Cerebral Palsy with Stem Cells: A Report of 17 Cases

    PubMed Central

    Abi Chahine, Nassim H.; Wehbe, Tarek W.; Hilal, Ramzi A.; Zoghbi, Victoria V.; Melki, Alia E.; Bou Habib, Emil B.

    2016-01-01

    Cerebral Palsy (CP) is a disabling condition that affects a child’s life and his/her family irreversibly. It is usually a non-progressive condition but improvement over time is rarely seen. The condition can be due to prenatal hypoxia, metabolic, genetic, infectious, traumatic or other causes. It is therefore a heterogeneous group that results in functional motor disability associated with different degrees of cognitive abnormalities. There are no treatments that can cure or even improve CP and the best available approach aims at functional, social and nutritional supportive care and counseling. In this paper, we report 17 sequential patients with CP treated with intrathecal administration of Bone Marrow Mononuclear Cells (BMMC). All patients had an uneventful post-injection course with 73% of the evaluable patients treated having a good response using the Gross Motor Function Classification System (GMFCS). The average improvement was 1.3 levels on the GMFCS with cognitive improvements as well. PMID:27426090

  3. ATR-FTIR membrane-based sensor for the simultaneous determination of surfactant and oil total indices in industrial degreasing baths.

    PubMed

    Lucena, Rafael; Cárdenas, Soledad; Gallego, Mercedes; Valcárcel, Miguel

    2006-03-01

    Monitoring the exhaustion of alkaline degreasing baths is one of the main aspects in metal mechanizing industrial process control. The global level of surfactant, and mainly grease, can be used as ageing indicators. In this paper, an attenuated total reflection-Fourier transform infrared (ATR-FTIR) membrane-based sensor is presented for the determination of these parameters. The system is based on a micro-liquid-liquid extraction of the analytes through a polymeric membrane from the aqueous to the organic solvent layer which is in close contact with the internal reflection element and continuously monitored. Samples are automatically processed using a simple, robust sequential injection analysis (SIA) configuration, on-line coupled to the instrument. The global signal obtained for both families of compounds are processed via a multivariate calibration technique (partial least squares, PLS). Excellent correlation was obtained for the values given by the proposed method compared to those of the gravimetric reference one with very low error values for both calibration and validation.

  4. Automated electronic tongue based on potentiometric sensors for the determination of a trinary anionic surfactant mixture.

    PubMed

    Cortina, Montserrat; Ecker, Christina; Calvo, Daniel; del Valle, Manuel

    2008-01-22

    An automated electronic tongue consisting of an array of potentiometric sensors and an artificial neural network (ANN) has been developed to resolve mixtures of anionic surfactants. The sensor array was formed by five different flow-through sensors for anionic surfactants, based on poly(vinyl chloride) membranes having cross-sensitivity features. Feedforward multilayer neural networks were used to predict surfactant concentrations. As a great amount of information is required for the correct modelling of the sensors response, a sequential injection analysis (SIA) system was used to automatically provide it. Dodecylsulfate (DS(-)), dodecylbenzenesulfonate (DBS(-)) and alpha-alkene sulfonate (ALF(-)) formed the three-analyte study case resolved in this work. Their concentrations varied from 0.2 to 4mM for ALF(-) and DBS(-) and from 0.2 to 5mM for DS(-). Good prediction ability was obtained with correlation coefficients better than 0.933 when the obtained values were compared with those expected for a set of 16 external test samples not used for training.

  5. Human factors in equipment development for the Space Shuttle - A study of the general purpose work station

    NASA Technical Reports Server (NTRS)

    Junge, M. K.; Giacomi, M. J.

    1981-01-01

    The results of a human factors test to assay the suitability of a prototype general purpose work station (GPWS) for biosciences experiments on the fourth Spacelab mission are reported. The evaluation was performed to verify that users of the GPWS would optimally interact with the GPWS configuration and instrumentation. Six male subjects sat on stools positioned to allow assimilation of the zero-g body posture. Trials were run concerning the operator viewing angles facing the console, the console color, procedures for injecting rates with dye, a rat blood cell count, mouse dissection, squirrel monkey transfer, and plant fixation. The trials were run for several days in order to gage improvement or poor performance conditions. Better access to the work surface was found necessary, together with more distinct and better located LEDs, better access window latches, clearer sequences on control buttons, color-coded sequential buttons, and provisions made for an intercom system when operators of the GPWS work in tandem.

  6. Sequential injection analysis with chemiluminescence detection for rapid monitoring of commercial Calendula officinalis extractions.

    PubMed

    Hughes, Rachel R; Scown, David; Lenehan, Claire E

    2015-01-01

    Plant extracts containing high levels of antioxidants are desirable due to their reported health benefits. Most techniques capable of determining the antioxidant activity of plant extracts are unsuitable for rapid at-line analysis as they require extensive sample preparation and/or long analysis times. Therefore, analytical techniques capable of real-time or pseudo real-time at-line monitoring of plant extractions, and determination of extraction endpoints, would be useful to manufacturers of antioxidant-rich plant extracts. To develop a reliable method for the rapid at-line extraction monitoring of antioxidants in plant extracts. Calendula officinalis extracts were prepared from dried flowers and analysed for antioxidant activity using sequential injection analysis (SIA) with chemiluminescence (CL) detection. The intensity of CL emission from the reaction of acidic potassium permanganate with antioxidants within the extract was used as the analytical signal. The SIA-CL method was applied to monitor the extraction of C. officinalis over the course of a batch extraction to determine the extraction endpoint. Results were compared with those from ultra high performance liquid chromatography (UHPLC). Pseudo real-time, at-line monitoring showed the level of antioxidants in a batch extract of Calendula officinalis plateaued after 100 min of extraction. These results correlated well with those of an offline UHPLC study. SIA-CL was found to be a suitable method for pseudo real-time monitoring of plant extractions and determination of extraction endpoints with respect to antioxidant concentrations. The method was applied at-line in the manufacturing industry. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Synthetic progestins induce growth and metastasis of BT-474 human breast cancer xenografts in nude mice.

    PubMed

    Liang, Yayun; Benakanakere, Indira; Besch-Williford, Cynthia; Hyder, Ryyan S; Ellersieck, Mark R; Hyder, Salman M

    2010-01-01

    Previous studies have shown that sequential exposure to estrogen and progesterone or medroxyprogesterone acetate (MPA) stimulates vascularization and promotes the progression of BT-474 and T47-D human breast cancer cell xenografts in nude mice (Liang et al, Cancer Res 2007, 67:9929). In this follow-up study, the effects of progesterone, MPA, norgestrel (N-EL), and norethindrone (N-ONE) on BT-474 xenograft tumors were compared in the context of several different hormonal environments. N-EL and N-ONE were included in the study because synthetic progestins vary considerably in their biological effects and the effects of these two progestins on the growth of human tumor xenografts are not known. Estradiol-supplemented intact and ovariectomized immunodeficient mice were implanted with BT-474 cells. Progestin pellets were implanted simultaneously with estradiol pellets either 2 days before tumor cell injection (ie, combined) or 5 days after tumor cell injections (ie, sequentially). Progestins stimulated the growth of BT-474 xenograft tumors independent of exposure timing and protocol, MPA stimulated the growth of BT-474 xenograft tumors in ovariectomized mice, and progestins stimulated vascular endothelial growth factor elaboration and increased tumor vascularity. Progestins also increased lymph node metastasis of BT-474 cells. Therefore, progestins, including N-EL and N-ONE, induce the progression of breast cancer xenografts in nude mice and promote tumor metastasis. These observations suggest that women who ingest progestins for hormone therapy or oral contraception could be more at risk for developing breast cancer because of proliferation of existing latent tumor cells. Such risks should be considered in the clinical setting.

  8. /sup 99m/Tc-fibrinogen scanning in adult respiratory distress syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, D.A.; Carvalho, A.C.; Geller, E.

    1987-01-01

    Fibrin is often seen occluding the lung vessels of patients dying from ARDS and is surrounded by regions of lung necrosis. To learn if we could observe increased or focal fibrin deposition and assess the kinetics of plasma fibrinogen turnover during severe acute respiratory failure, we injected technetium 99m-labeled human purified fibrinogen (Tc-HF) and used gamma camera scanning for as long as 12 h in 13 sequential patients as soon as possible after ICU admission. The fibrinogen uptake rates were determined by calculating the lung:heart radioactivity ratios at each time point. Slopes of the lung:heart ratio versus time were comparedmore » between ARDS and mild acute respiratory failure (ARF). The slope of the lung:heart Tc-HF ratio of the 9 patients with ARDS (2.9 +/- 0.4 units) was markedly higher (p less than 0.02) than the slope of the 4 patients with mild ARF (1.1 +/- 0.4) and the 3 patients studied 5 to 9 months after recovery from respiratory failure (0.7 +/- 0.07). In the 1 patient with ARDS and the 2 patients with mild ARF studied both during acute lung injury and after recovery, the lung:heart Tc-HF ratio had decreased at recovery. To compare the pulmonary uptake of Tc-HF to /sup 99m/Tc-labeled human serum albumin (Tc-HSA), 5 patients were injected with 10 mCi of Tc-HSA, and scanning of the thorax was performed with a similar sequential imaging protocol 24 h after conclusion of the Tc-HF study.« less

  9. Fast-responding liquid crystal light-valve technology for color-sequential display applications

    NASA Astrophysics Data System (ADS)

    Janssen, Peter J.; Konovalov, Victor A.; Muravski, Anatoli A.; Yakovenko, Sergei Y.

    1996-04-01

    A color sequential projection system has some distinct advantages over conventional systems which make it uniquely suitable for consumer TV as well as high performance professional applications such as computer monitors and electronic cinema. A fast responding light-valve is, clearly, essential for a good performing system. Response speed of transmissive LC lightvalves has been marginal thus far for good color rendition. Recently, Sevchenko Institute has made some very fast reflective LC cells which were evaluated at Philips Labs. These devices showed sub millisecond-large signal-response times, even at room temperature, and produced good color in a projector emulation testbed. In our presentation we describe our highly efficient color sequential projector and demonstrate its operation on video tape. Next we discuss light-valve requirements and reflective light-valve test results.

  10. Eyewitness confidence in simultaneous and sequential lineups: a criterion shift account for sequential mistaken identification overconfidence.

    PubMed

    Dobolyi, David G; Dodson, Chad S

    2013-12-01

    Confidence judgments for eyewitness identifications play an integral role in determining guilt during legal proceedings. Past research has shown that confidence in positive identifications is strongly associated with accuracy. Using a standard lineup recognition paradigm, we investigated accuracy using signal detection and ROC analyses, along with the tendency to choose a face with both simultaneous and sequential lineups. We replicated past findings of reduced rates of choosing with sequential as compared to simultaneous lineups, but notably found an accuracy advantage in favor of simultaneous lineups. Moreover, our analysis of the confidence-accuracy relationship revealed two key findings. First, we observed a sequential mistaken identification overconfidence effect: despite an overall reduction in false alarms, confidence for false alarms that did occur was higher with sequential lineups than with simultaneous lineups, with no differences in confidence for correct identifications. This sequential mistaken identification overconfidence effect is an expected byproduct of the use of a more conservative identification criterion with sequential than with simultaneous lineups. Second, we found a steady drop in confidence for mistaken identifications (i.e., foil identifications and false alarms) from the first to the last face in sequential lineups, whereas confidence in and accuracy of correct identifications remained relatively stable. Overall, we observed that sequential lineups are both less accurate and produce higher confidence false identifications than do simultaneous lineups. Given the increasing prominence of sequential lineups in our legal system, our data argue for increased scrutiny and possibly a wholesale reevaluation of this lineup format. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  11. Improved solution accuracy for TDRSS-based TOPEX/Poseidon orbit determination

    NASA Technical Reports Server (NTRS)

    Doll, C. E.; Mistretta, G. D.; Hart, R. C.; Oza, D. H.; Bolvin, D. T.; Cox, C. M.; Nemesure, M.; Niklewski, D. J.; Samii, M. V.

    1994-01-01

    Orbit determination results are obtained by the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) using a batch-least-squares estimator available in the Goddard Trajectory Determination System (GTDS) and an extended Kalman filter estimation system to process Tracking and Data Relay Satellite (TDRS) System (TDRSS) measurements. GTDS is the operational orbit determination system used by the FDD in support of the Ocean Topography Experiment (TOPEX)/Poseidon spacecraft navigation and health and safety operations. The extended Kalman filter was implemented in an orbit determination analysis prototype system, closely related to the Real-Time Orbit Determination System/Enhanced (RTOD/E) system. In addition, the Precision Orbit Determination (POD) team within the GSFC Space Geodesy Branch generated an independent set of high-accuracy trajectories to support the TOPEX/Poseidon scientific data. These latter solutions use the geodynamics (GEODYN) orbit determination system with laser ranging and Doppler Orbitography and Radiopositioning integrated by satellite (DORIS) tracking measurements. The TOPEX/Poseidon trajectories were estimated for November 7 through November 11, 1992, the timeframe under study. Independent assessments were made of the consistencies of solutions produced by the batch and sequential methods. The batch-least-squares solutions were assessed based on the solution residuals, while the sequential solutions were assessed based on primarily the estimated covariances. The batch-least-squares and sequential orbit solutions were compared with the definitive POD orbit solutions. The solution differences were generally less than 2 meters for the batch-least-squares and less than 13 meters for the sequential estimation solutions. After the sequential estimation solutions were processed with a smoother algorithm, position differences with POD orbit solutions of less than 7 meters were obtained. The differences among the POD, GTDS, and filter/smoother solutions can be traced to differences in modeling and tracking data types, which are being analyzed in detail.

  12. SSME propellant path leak detection real-time

    NASA Technical Reports Server (NTRS)

    Crawford, R. A.; Smith, L. M.

    1994-01-01

    Included are four documents that outline the technical aspects of the research performed on NASA Grant NAG8-140: 'A System for Sequential Step Detection with Application to Video Image Processing'; 'Leak Detection from the SSME Using Sequential Image Processing'; 'Digital Image Processor Specifications for Real-Time SSME Leak Detection'; and 'A Color Change Detection System for Video Signals with Applications to Spectral Analysis of Rocket Engine Plumes'.

  13. Pharmacokinetics of 99mTc-MAA- and 99mTc-HSA-Microspheres Used in Preradioembolization Dosimetry: Influence on the Liver-Lung Shunt.

    PubMed

    Grosser, Oliver S; Ruf, Juri; Kupitz, Dennis; Pethe, Annette; Ulrich, Gerhard; Genseke, Philipp; Mohnike, Konrad; Pech, Maciej; Richter, Wolf S; Ricke, Jens; Amthauer, Holger

    2016-06-01

    Perfusion scintigraphy using (99m)Tc-labeled albumin aggregates is mandatory before hepatic radioembolization with (90)Y-microspheres. As part of a prospective trial, the intrahepatic and intrapulmonary stability of 2 albumin compounds, (99m)Tc-MAA (macroaggregated serum albumin [MAA]) and (99m)Tc-HSA (human serum albumin [HSA]), was assessed. In 24 patients with metastatic colorectal cancer, biodistribution (liver, lung) and liver-lung shunt (LLS) of both tracers (12 patients each) were assessed by sequential planar scintigraphy (1, 5, and 24 h after injection). Liver uptake of both albumin compounds decreased differently. Although initial LLSs at 1 h after injection were similar in both groups, MAA-LLS increased significantly from 1 (3.9%) to 5 h (7.7%) and 24 h (9.9%) after injection, respectively. HSA-LLS did not change significantly (1 to 5 h), indicating a steady state of pulmonary and intrahepatic degradation. Compared with (99m)Tc-MAA-microspheres, (99m)Tc-HSA-microspheres are likely more resistant to degradation over time, allowing a reliable LLS determination even at later time points. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. Employment-based abstinence reinforcement promotes opiate and cocaine abstinence in out-of-treatment injection drug users.

    PubMed

    Holtyn, August F; Koffarnus, Mikhail N; DeFulio, Anthony; Sigurdsson, Sigurdur O; Strain, Eric C; Schwartz, Robert P; Silverman, Kenneth

    2014-01-01

    We examined the use of employment-based abstinence reinforcement in out-of-treatment injection drug users, in this secondary analysis of a previously reported trial. Participants (N = 33) could work in the therapeutic workplace, a model employment-based program for drug addiction, for 30 weeks and could earn approximately $10 per hr. During a 4-week induction, participants only had to work to earn pay. After induction, access to the workplace was contingent on enrollment in methadone treatment. After participants met the methadone contingency for 3 weeks, they had to provide opiate-negative urine samples to maintain maximum pay. After participants met those contingencies for 3 weeks, they had to provide opiate- and cocaine-negative urine samples to maintain maximum pay. The percentage of drug-negative urine samples remained stable until the abstinence reinforcement contingency for each drug was applied. The percentage of opiate- and cocaine-negative urine samples increased abruptly and significantly after the opiate- and cocaine-abstinence contingencies, respectively, were applied. These results demonstrate that the sequential administration of employment-based abstinence reinforcement can increase opiate and cocaine abstinence among out-of-treatment injection drug users. © Society for the Experimental Analysis of Behavior.

  15. EMPLOYMENT-BASED ABSTINENCE REINFORCEMENT PROMOTES OPIATE AND COCAINE ABSTINENCE IN OUT-OF-TREATMENT INJECTION DRUG USERS

    PubMed Central

    Holtyn, August F.; Koffarnus, Mikhail N.; DeFulio, Anthony; Sigurdsson, Sigurdur O.; Strain, Eric C.; Schwartz, Robert P.; Silverman, Kenneth

    2016-01-01

    We examined the use of employment-based abstinence reinforcement in out-of-treatment injection drug users, in this secondary analysis of a previously reported trial. Participants (N = 33) could work in the therapeutic workplace, a model employment-based program for drug addiction, for 30 weeks and could earn approximately $10 per hr. During a 4-week induction, participants only had to work to earn pay. After induction, access to the workplace was contingent on enrollment in methadone treatment. After participants met the methadone contingency for 3 weeks, they had to provide opiate-negative urine samples to maintain maximum pay. After participants met those contingencies for 3 weeks, they had to provide opiate- and cocaine-negative urine samples to maintain maximum pay. The percentage of drug-negative urine samples remained stable until the abstinence reinforcement contingency for each drug was applied. The percentage of opiate- and cocaine-negative urine samples increased abruptly and significantly after the opiate- and cocaine-abstinence contingencies, respectively, were applied. These results demonstrate that the sequential administration of employment-based abstinence reinforcement can increase opiate and cocaine abstinence among out-of-treatment injection drug users. PMID:25292399

  16. What Effect Does Ethnicity Have on the Response to Ranibizumab in the Treatment of Wet Age-Related Macular Degeneration?

    PubMed

    Mohamed, Ryian; Gadhvi, Kunal; Mensah, Evelyn

    2018-05-30

    To compare, in a single urban population, the visual outcomes of ranibizumab monotherapy in "White" (W) and "Non-White" (NW) patients with wet age-related macular degeneration (AMD). Prospective data was collected from 434 eyes of 217 patients with wet AMD patients receiving intravitreal ranibizumab. Baseline and monthly LogMAR visual acuities were obtained. All patients received treatment under a "treat and extend policy" consisting of three monthly injections of ranibizumab, followed by individualised sequentially lengthening follow-up intervals when stable. At 24 months, the percentage of eyes that maintained or improved vision was 91% in W patients and 83% in NW patients. Correspondingly, at 24 months, the percentage of visual loss was 9% for W patients and 17% of NW patients. We found that whilst W patients required fewer overall injections (14.1) they gained an average 4 LogMAR letters of visual acuity. However, NW patients required more injections (14.6) to gain 0.5 LogMAR letters of visual acuity over the same 24 months of treatment. Individualised ranibizumab monotherapy is more effective in preserving vision for W compared to NW patients with wet AMD. © 2018 S. Karger AG, Basel.

  17. Injecting 1000 centistoke liquid silicone with ease and precision.

    PubMed

    Benedetto, Anthony V; Lewis, Alan T

    2003-03-01

    Since the Food and Drug Administration approved the use of the 1000 centistoke liquid silicone, Silikon 1000, for intraocular injection, the off-label use of this injectable silicone oil as a permanent soft-tissue filler for facial rejuvenation has increased in the United States. Injecting liquid silicone by the microdroplet technique is the most important preventive measure that one can use to avoid the adverse sequelae of silicone migration and granuloma formation, especially when injecting silicone to improve small facial defects resulting from acne scars, surgical procedures, or photoaging. To introduce an easy method for injecting a viscous silicone oil by the microdroplet technique, using an inexpensive syringe and needle that currently is available from distributors of medical supplies in the United States. We suggest the use of a Becton Dickinson 3/10 cc insulin U-100 syringe to inject Silikon 1000. This syringe contains up to 0.3 mL of fluid, and its barrel is clearly marked with an easy-to-read scale of large cross-hatches. Each cross-hatch marking represents either a unit value of 0.01 mL or a half-unit value of 0.005 mL of fluid, which is the approximate volume preferred when injecting liquid silicone into facial defects. Because not enough negative pressure can be generated in this needle and syringe to draw up the viscous silicone oil, we describe a convenient and easy method for filling this 3/10 cc diabetic syringe with Silikon 1000. We have found that by using the Becton Dickinson 3/10 cc insulin U-100 syringe, our technique of injecting minute amounts of Silikon 1000 is facilitated because each widely spaced cross-hatch on the side of the syringe barrel is easy to read and measures exact amounts of the silicone oil. These lines of the scale on the syringe barrel are so large and clearly marked that it is virtually impossible to overinject the most minute amount of silicone. Sequential microdroplets of 0.01 cc or less of Silikon 1000 can be measured and injected with the greatest ease and precision so that inadvertent overdosing and complications can be avoided.

  18. Microwave Ablation: Comparison of Simultaneous and Sequential Activation of Multiple Antennas in Liver Model Systems

    PubMed Central

    Harari, Colin M.; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T.; Lubner, Meghan G.; Hinshaw, J. Louis; Ziemlewicz, Timothy

    2016-01-01

    Purpose To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. Materials and Methods All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. Results On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P < .05). Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P < .05). Ablations were generally smaller in vivo compared with ex vivo. Conclusion The use of multiple antennas and simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015 PMID:26133361

  19. Small Molecule Sequential Dual-Targeting Theragnostic Strategy (SMSDTTS): from Preclinical Experiments towards Possible Clinical Anticancer Applications

    PubMed Central

    Li, Junjie; Oyen, Raymond; Verbruggen, Alfons; Ni, Yicheng

    2013-01-01

    Hitting the evasive tumor cells proves challenging in targeted cancer therapies. A general and unconventional anticancer approach namely small molecule sequential dual-targeting theragnostic strategy (SMSDTTS) has recently been introduced with the aims to target and debulk the tumor mass, wipe out the residual tumor cells, and meanwhile enable cancer detectability. This dual targeting approach works in two steps for systemic delivery of two naturally derived drugs. First, an anti-tubulin vascular disrupting agent, e.g., combretastatin A4 phosphate (CA4P), is injected to selectively cut off tumor blood supply and to cause massive necrosis, which nevertheless always leaves peripheral tumor residues. Secondly, a necrosis-avid radiopharmaceutical, namely 131I-hypericin (131I-Hyp), is administered the next day, which accumulates in intratumoral necrosis and irradiates the residual cancer cells with beta particles. Theoretically, this complementary targeted approach may biologically and radioactively ablate solid tumors and reduce the risk of local recurrence, remote metastases, and thus cancer mortality. Meanwhile, the emitted gamma rays facilitate radio-scintigraphy to detect tumors and follow up the therapy, hence a simultaneous theragnostic approach. SMSDTTS has now shown promise from multicenter animal experiments and may demonstrate unique anticancer efficacy in upcoming preliminary clinical trials. In this short review article, information about the two involved agents, the rationale of SMSDTTS, its preclinical antitumor efficacy, multifocal targetability, simultaneous theragnostic property, and toxicities of the dose regimens are summarized. Meanwhile, possible drawbacks, practical challenges and future improvement with SMSDTTS are discussed, which hopefully may help to push forward this strategy from preclinical experiments towards possible clinical applications. PMID:23412554

  20. Small Molecule Sequential Dual-Targeting Theragnostic Strategy (SMSDTTS): from Preclinical Experiments towards Possible Clinical Anticancer Applications.

    PubMed

    Li, Junjie; Oyen, Raymond; Verbruggen, Alfons; Ni, Yicheng

    2013-01-01

    Hitting the evasive tumor cells proves challenging in targeted cancer therapies. A general and unconventional anticancer approach namely small molecule sequential dual-targeting theragnostic strategy (SMSDTTS) has recently been introduced with the aims to target and debulk the tumor mass, wipe out the residual tumor cells, and meanwhile enable cancer detectability. This dual targeting approach works in two steps for systemic delivery of two naturally derived drugs. First, an anti-tubulin vascular disrupting agent, e.g., combretastatin A4 phosphate (CA4P), is injected to selectively cut off tumor blood supply and to cause massive necrosis, which nevertheless always leaves peripheral tumor residues. Secondly, a necrosis-avid radiopharmaceutical, namely (131)I-hypericin ((131)I-Hyp), is administered the next day, which accumulates in intratumoral necrosis and irradiates the residual cancer cells with beta particles. Theoretically, this complementary targeted approach may biologically and radioactively ablate solid tumors and reduce the risk of local recurrence, remote metastases, and thus cancer mortality. Meanwhile, the emitted gamma rays facilitate radio-scintigraphy to detect tumors and follow up the therapy, hence a simultaneous theragnostic approach. SMSDTTS has now shown promise from multicenter animal experiments and may demonstrate unique anticancer efficacy in upcoming preliminary clinical trials. In this short review article, information about the two involved agents, the rationale of SMSDTTS, its preclinical antitumor efficacy, multifocal targetability, simultaneous theragnostic property, and toxicities of the dose regimens are summarized. Meanwhile, possible drawbacks, practical challenges and future improvement with SMSDTTS are discussed, which hopefully may help to push forward this strategy from preclinical experiments towards possible clinical applications.

  1. Dexamethasone levels and base to apex concentration gradients in scala tympani perilymph following intracochlear delivery in the guinea pig

    PubMed Central

    Hahn, Hartmut; Salt, Alec N.; Biegner, Thorsten; Kammerer, Bernd; Delabar, Ursular; Hartsock, Jared; Plontke, Stefan K.

    2012-01-01

    Hypothesis To determine whether intracochlearly applied dexamethasone will lead to better control of drug levels, higher peak concentrations and lower base-to apex concentration gradients in scala tympani (ST) of the guinea pig than after intratympanic (round window, RW) application. Background Local application of drugs to the RW results in substantial variation of intracochlear drug levels and significant base-to apex concentration gradients in ST. Methods Two μL of dexamethasone-phosphate (10 mg/mL) were injected into ST either through the RW membrane which was covered with 1% sodium hyaluronate gel or through a cochleostomy with a fluid tight seal of the micropipette. Perilymph was sequentially sampled from the apex at a single time point for each animal, at 20, 80, or 200 min after the injection ended. Results were mathematically interpreted by the means of an established computer model and compared with prior experiments performed by our group with the same experimental techniques but using intratympanic applications. Results Single intracochlear injections over 20 min resulted in approximately ten times higher peak concentrations (on average) than 2-3 hours of intratympanic application to the round window niche. Intracochlear drug levels were less variable and could be measured for at least up to 220 min. Concentration gradients along scala tympani were less pronounced. The remaining variability in intracochlear drug levels was attributable to perilymph and drug leak from the injection site. Conclusion With significantly higher, less variable drug levels and smaller base-to apex concentration gradients, intracochlear applications have advantages to intratympanic injections. For further development of this technique, it is of importance to control leaks of perilymph and drug from the injection site and to evaluate its clinical feasibility and associated risks. PMID:22588238

  2. Dexamethasone levels and base-to-apex concentration gradients in the scala tympani perilymph after intracochlear delivery in the guinea pig.

    PubMed

    Hahn, Hartmut; Salt, Alec N; Biegner, Thorsten; Kammerer, Bernd; Delabar, Ursular; Hartsock, Jared J; Plontke, Stefan K

    2012-06-01

    To determine whether intracochlearly applied dexamethasone will lead to better control of drug levels, higher peak concentrations, and lower base-to-apex concentration gradients in the scala tympani (ST) of the guinea pig than after intratympanic (round window [RW]) application. Local application of drugs to the RW results in substantial variation of intracochlear drug levels and significant base-to-apex concentration gradients in ST. Two microliters of dexamethasone-phosphate (10 mg/ml) were injected into ST either through the RW membrane, which was covered with 1% sodium hyaluronate gel or through a cochleostomy with a fluid tight seal of the micropipette. Perilymph was sequentially sampled from the apex at a single time point for each animal, at 20, 80, or 200 min after the injection ended. Results were mathematically interpreted by means of an established computer model and compared with previous experiments performed by our group with the same experimental techniques but using intratympanic applications. Single intracochlear injections of 20 minutes resulted in approximately 10 times higher peak concentrations (on average) than 2 to 3 hours of intratympanic application to the RW niche. Intracochlear drug levels were less variable and could be measured for over 220 minutes. Concentration gradients along the scala tympani were less pronounced. The remaining variability in intracochlear drug levels was attributable to perilymph and drug leak from the injection site. With significantly higher, less variable drug levels and smaller base-to-apex concentration gradients, intracochlear applications have advantages to intratympanic injections. For further development of this technique, it is of importance to control leaks of perilymph and drug from the injection site and to evaluate its clinical feasibility and associated risks.

  3. Patterns of Drug Use, Risky Behavior, and Health Status Among Persons Who Inject Drugs Living in San Diego, California: A Latent Class Analysis

    PubMed Central

    Roth, Alexis M.; Armenta, Richard A.; Wagner, Karla D.; Roesch, Scott C.; Bluthenthal, Ricky N.; Cuevas-Mota, Jazmine; Garfein, Richard S.

    2015-01-01

    Background Among persons who inject drugs (PWID), polydrug use (the practice of mixing multiple drugs/alcohol sequentially or simultaneously) increases risk for HIV transmission and unintentional overdose deaths. Research has shown local drug markets influence drug use practices. However, little is known about the impact of drug mixing in markets dominated by black tar heroin and methamphetamine, such as the western United States. Methods Data were collected through an ongoing longitudinal study examining drug use, risk behavior, and health status among PWID. Latent class analysis (LCA) was used to identify patterns of substance use (heroin, methamphetamine, prescription drugs, alcohol, and marijuana) via multiple administration routes (injecting, smoking, and swallowing). Logistic regression was used to identify behaviors and health indicators associated with drug use class. Results The sample included 511 mostly white (51.5%) males (73.8%), with mean age of 43.5 years. Two distinct classes of drug users predominated: methamphetamine by multiple routes (51%) and heroin by injection (49%). In multivariable logistic regression, class membership was associated with age, race, and housing status. PWID who were HIV-seropositive and reported prior sexually transmitted infections had increased odds of belonging to the methamphetamine class. Those who were HCV positive and reported previous opioid overdose had an increased odds of being in the primarily heroin injection class (all P-values < .05). Conclusion Risk behaviors and health outcomes differed between PWID who primarily inject heroin vs. those who use methamphetamine. The findings suggest that in a region where PWID mainly use black tar heroin or methamphetamine, interventions tailored to sub-populations of PWID could improve effectiveness. PMID:25313832

  4. On the origin of reproducible sequential activity in neural circuits

    NASA Astrophysics Data System (ADS)

    Afraimovich, V. S.; Zhigulin, V. P.; Rabinovich, M. I.

    2004-12-01

    Robustness and reproducibility of sequential spatio-temporal responses is an essential feature of many neural circuits in sensory and motor systems of animals. The most common mathematical images of dynamical regimes in neural systems are fixed points, limit cycles, chaotic attractors, and continuous attractors (attractive manifolds of neutrally stable fixed points). These are not suitable for the description of reproducible transient sequential neural dynamics. In this paper we present the concept of a stable heteroclinic sequence (SHS), which is not an attractor. SHS opens the way for understanding and modeling of transient sequential activity in neural circuits. We show that this new mathematical object can be used to describe robust and reproducible sequential neural dynamics. Using the framework of a generalized high-dimensional Lotka-Volterra model, that describes the dynamics of firing rates in an inhibitory network, we present analytical results on the existence of the SHS in the phase space of the network. With the help of numerical simulations we confirm its robustness in presence of noise in spite of the transient nature of the corresponding trajectories. Finally, by referring to several recent neurobiological experiments, we discuss possible applications of this new concept to several problems in neuroscience.

  5. On the origin of reproducible sequential activity in neural circuits.

    PubMed

    Afraimovich, V S; Zhigulin, V P; Rabinovich, M I

    2004-12-01

    Robustness and reproducibility of sequential spatio-temporal responses is an essential feature of many neural circuits in sensory and motor systems of animals. The most common mathematical images of dynamical regimes in neural systems are fixed points, limit cycles, chaotic attractors, and continuous attractors (attractive manifolds of neutrally stable fixed points). These are not suitable for the description of reproducible transient sequential neural dynamics. In this paper we present the concept of a stable heteroclinic sequence (SHS), which is not an attractor. SHS opens the way for understanding and modeling of transient sequential activity in neural circuits. We show that this new mathematical object can be used to describe robust and reproducible sequential neural dynamics. Using the framework of a generalized high-dimensional Lotka-Volterra model, that describes the dynamics of firing rates in an inhibitory network, we present analytical results on the existence of the SHS in the phase space of the network. With the help of numerical simulations we confirm its robustness in presence of noise in spite of the transient nature of the corresponding trajectories. Finally, by referring to several recent neurobiological experiments, we discuss possible applications of this new concept to several problems in neuroscience.

  6. Information Retrieval: A Sequential Learning Process.

    ERIC Educational Resources Information Center

    Bookstein, Abraham

    1983-01-01

    Presents decision-theoretic models which intrinsically include retrieval of multiple documents whereby system responds to request by presenting documents to patron in sequence, gathering feedback, and using information to modify future retrievals. Document independence model, set retrieval model, sequential retrieval model, learning model,…

  7. Evaluation of Landsat-4 orbit determination accuracy using batch least-squares and sequential methods

    NASA Astrophysics Data System (ADS)

    Oza, D. H.; Jones, T. L.; Feiertag, R.; Samii, M. V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite (TDRS) System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the May 18-24, 1992, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. During this period, there were two separate orbit-adjust maneuvers on one of the TDRSS spacecraft (TDRS-East) and one small orbit-adjust maneuver for Landsat-4. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 30 meters after the filter had reached steady state.

  8. Evaluation of Landsat-4 orbit determination accuracy using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Feiertag, R.; Samii, M. V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    1993-01-01

    The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite (TDRS) System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the May 18-24, 1992, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. During this period, there were two separate orbit-adjust maneuvers on one of the TDRSS spacecraft (TDRS-East) and one small orbit-adjust maneuver for Landsat-4. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 30 meters after the filter had reached steady state.

  9. Nonequilibrium Statistical Mechanics in One Dimension

    NASA Astrophysics Data System (ADS)

    Privman, Vladimir

    2005-08-01

    Part I. Reaction-Diffusion Systems and Models of Catalysis; 1. Scaling theories of diffusion-controlled and ballistically-controlled bimolecular reactions S. Redner; 2. The coalescence process, A+A->A, and the method of interparticle distribution functions D. ben-Avraham; 3. Critical phenomena at absorbing states R. Dickman; Part II. Kinetic Ising Models; 4. Kinetic ising models with competing dynamics: mappings, correlations, steady states, and phase transitions Z. Racz; 5. Glauber dynamics of the ising model N. Ito; 6. 1D Kinetic ising models at low temperatures - critical dynamics, domain growth, and freezing S. Cornell; Part III. Ordering, Coagulation, Phase Separation; 7. Phase-ordering dynamics in one dimension A. J. Bray; 8. Phase separation, cluster growth, and reaction kinetics in models with synchronous dynamics V. Privman; 9. Stochastic models of aggregation with injection H. Takayasu and M. Takayasu; Part IV. Random Sequential Adsorption and Relaxation Processes; 10. Random and cooperative sequential adsorption: exactly solvable problems on 1D lattices, continuum limits, and 2D extensions J. W. Evans; 11. Lattice models of irreversible adsorption and diffusion P. Nielaba; 12. Deposition-evaporation dynamics: jamming, conservation laws and dynamical diversity M. Barma; Part V. Fluctuations In Particle and Surface Systems; 13. Microscopic models of macroscopic shocks S. A. Janowsky and J. L. Lebowitz; 14. The asymmetric exclusion model: exact results through a matrix approach B. Derrida and M. R. Evans; 15. Nonequilibrium surface dynamics with volume conservation J. Krug; 16. Directed walks models of polymers and wetting J. Yeomans; Part VI. Diffusion and Transport In One Dimension; 17. Some recent exact solutions of the Fokker-Planck equation H. L. Frisch; 18. Random walks, resonance, and ratchets C. R. Doering and T. C. Elston; 19. One-dimensional random walks in random environment K. Ziegler; Part VII. Experimental Results; 20. Diffusion-limited exciton kinetics in one-dimensional systems R. Kroon and R. Sprik; 21. Experimental investigations of molecular and excitonic elementary reaction kinetics in one-dimensional systems R. Kopelman and A. L. Lin; 22. Luminescence quenching as a probe of particle distribution S. H. Bossmann and L. S. Schulman; Index.

  10. Sequential Testing of Hypotheses Concerning the Reliability of a System Modeled by a Two-Parameter Weibull Distribution.

    DTIC Science & Technology

    1981-12-01

    CONCERNING THE RELIABILITY OF A SYSTEM MODELED BY A TWO-PARAMETER WEIBULL DISTRIBUTION THESIS AFIT/GOR/MA/81D-8 Philippe A. Lussier 2nd Lt USAF... MODELED BY A TWO-PARAMETER WEIBULL DISTRIBUTION THESIS Presented to the Faculty of the School of Engineering of the Air Force Institute of Technology...repetitions are used for these test procedures. vi Sequential Testing of Hypotheses Concerning the Reliability of a System Modeled by a Two-Parameter

  11. Fuel mixture stratification as a method for improving homogeneous charge compression ignition engine operation

    DOEpatents

    Dec, John E [Livermore, CA; Sjoberg, Carl-Magnus G [Livermore, CA

    2006-10-31

    A method for slowing the heat-release rate in homogeneous charge compression ignition ("HCCI") engines that allows operation without excessive knock at higher engine loads than are possible with conventional HCCI. This method comprises injecting a fuel charge in a manner that creates a stratified fuel charge in the engine cylinder to provide a range of fuel concentrations in the in-cylinder gases (typically with enough oxygen for complete combustion) using a fuel with two-stage ignition fuel having appropriate cool-flame chemistry so that regions of different fuel concentrations autoignite sequentially.

  12. A cost and policy analysis comparing immediate sequential cataract surgery and delayed sequential cataract surgery from the physician perspective in the United States.

    PubMed

    Neel, Sean T

    2014-11-01

    A cost analysis was performed to evaluate the effect on physicians in the United States of a transition from delayed sequential cataract surgery to immediate sequential cataract surgery. Financial and efficiency impacts of this change were evaluated to determine whether efficiency gains could offset potential reduced revenue. A cost analysis using Medicare cataract surgery volume estimates, Medicare 2012 physician cataract surgery reimbursement schedules, and estimates of potential additional office visit revenue comparing immediate sequential cataract surgery with delayed sequential cataract surgery for a single specialty ophthalmology practice in West Tennessee. This model should give an indication of the effect on physicians on a national basis. A single specialty ophthalmology practice in West Tennessee was found to have a cataract surgery revenue loss of $126,000, increased revenue from office visits of $34,449 to $106,271 (minimum and maximum offset methods), and a net loss of $19,900 to $91,700 (base case) with the conversion to immediate sequential cataract surgery. Physicians likely stand to lose financially, and this loss cannot be offset by increased patient visits under the current reimbursement system. This may result in physician resistance to converting to immediate sequential cataract surgery, gaming, and supplier-induced demand.

  13. Near-Infrared Imaging Method for the In Vivo Assessment of the Biodistribution of Nanoporous Silicon Particles

    PubMed Central

    Tasciotti, Ennio; Godin, Biana; Martinez, Jonathan O.; Chiappini, Ciro; Bhavane, Rohan; Liu, Xuewu; Ferrari, Mauro

    2011-01-01

    In the development of new nanoparticle-based technologies for therapeutic and diagnostic purposes, understanding the fate of nanoparticles in the body is crucial. We recently developed a multistage vector delivery system comprising biodegradable and biocompatible nanoporous silicon particles (first-stage microparticles [S1MPs]) able to host, protect, and deliver second-stage therapeutic and diagnostic nanoparticles (S2NPs) on intravenous injection. This delivery system aims at sequentially overcoming the biologic barriers en route to the target delivery site by separating and assigning tasks to the coordinated logic-embedded vectors constituting it. In this work, by conjugating a near-infrared dye on the surface of the S1MP without compromising the porous structure and potential loading of S2NPs, we were able to monitor the in vivo distribution of S1MPs in healthy mice using an optical imaging system. It was observed that particles predominantly accumulated in the liver and spleen at the end of 24 hours. Further quantification of S1MPs in the major organs of the animals by elemental analysis of silicon using inductively coupled plasma-atomic electron spectroscopy verified the accuracy of in vivo near-infrared imaging as a tool for evaluation of nanovector biodistribution. PMID:21303615

  14. Phase-Space Detection of Cyber Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez Jimenez, Jarilyn M; Ferber, Aaron E; Prowell, Stacy J

    Energy Delivery Systems (EDS) are a network of processes that produce, transfer and distribute energy. EDS are increasingly dependent on networked computing assets, as are many Industrial Control Systems. Consequently, cyber-attacks pose a real and pertinent threat, as evidenced by Stuxnet, Shamoon and Dragonfly. Hence, there is a critical need for novel methods to detect, prevent, and mitigate effects of such attacks. To detect cyber-attacks in EDS, we developed a framework for gathering and analyzing timing data that involves establishing a baseline execution profile and then capturing the effect of perturbations in the state from injecting various malware. The datamore » analysis was based on nonlinear dynamics and graph theory to improve detection of anomalous events in cyber applications. The goal was the extraction of changing dynamics or anomalous activity in the underlying computer system. Takens' theorem in nonlinear dynamics allows reconstruction of topologically invariant, time-delay-embedding states from the computer data in a sufficiently high-dimensional space. The resultant dynamical states were nodes, and the state-to-state transitions were links in a mathematical graph. Alternatively, sequential tabulation of executing instructions provides the nodes with corresponding instruction-to-instruction links. Graph theorems guarantee graph-invariant measures to quantify the dynamical changes in the running applications. Results showed a successful detection of cyber events.« less

  15. Determination of methylmercury and inorganic mercury in water samples by slurry sampling cold vapor atomic absorption spectrometry in a flow injection system after preconcentration on silica C(18) modified.

    PubMed

    Segade, Susana Río; Tyson, Julian F

    2007-03-15

    A novel method for preconcentration of methylmercury and inorganic mercury from water samples was developed involving the determination of ngl(-1) levels of analytes retained on the silica C(18) solid sorbent, previous complexation with ammonium pyrrolidine dithiocarbamate (APDC), by slurry sampling cold vapor atomic absorption spectrometry (SS-CVAAS) in a flow injection (FI) system. Several variables were optimized affecting either the retention of both mercury species, such as APDC concentration, silica C(18) amount, agitation times, or their determination, including hydrochloric acid concentration in the suspension medium, peristaltic pump speed and argon flow-rate. A Plackett-Burman saturated factorial design permitted to differentiate the influential parameters on the preconcentration efficiency, which were after optimized by the sequential simplex method. The contact time between mercury containing solution and APDC, required to reach an efficient sorption, was decreased from 26 to 3min by the use of sonication stirring instead of magnetic stirring. The use of 1moldm(-3) hydrochloric acid suspension medium and 0.75% (m/v) sodium borohydride reducing agent permitted the selective determination of methylmercury. The combination of 5moldm(-3) hydrochloric acid and 10(-4)% (m/v) sodium borohydride was used for the selective determination of inorganic mercury. The detection limits achieved for methylmercury and inorganic mercury determination under optimum conditions were 0.96 and 0.25ngl(-1), respectively. The reliability of the proposed method for the determination of both mercury species in waters was checked by the analysis of samples spiked with known concentrations of methylmercury and inorganic mercury; quantitative recoveries were obtained.

  16. Sequential design of discrete linear quadratic regulators via optimal root-locus techniques

    NASA Technical Reports Server (NTRS)

    Shieh, Leang S.; Yates, Robert E.; Ganesan, Sekar

    1989-01-01

    A sequential method employing classical root-locus techniques has been developed in order to determine the quadratic weighting matrices and discrete linear quadratic regulators of multivariable control systems. At each recursive step, an intermediate unity rank state-weighting matrix that contains some invariant eigenvectors of that open-loop matrix is assigned, and an intermediate characteristic equation of the closed-loop system containing the invariant eigenvalues is created.

  17. Sequential Feedback Scheme Outperforms the Parallel Scheme for Hamiltonian Parameter Estimation.

    PubMed

    Yuan, Haidong

    2016-10-14

    Measurement and estimation of parameters are essential for science and engineering, where the main quest is to find the highest achievable precision with the given resources and design schemes to attain it. Two schemes, the sequential feedback scheme and the parallel scheme, are usually studied in the quantum parameter estimation. While the sequential feedback scheme represents the most general scheme, it remains unknown whether it can outperform the parallel scheme for any quantum estimation tasks. In this Letter, we show that the sequential feedback scheme has a threefold improvement over the parallel scheme for Hamiltonian parameter estimations on two-dimensional systems, and an order of O(d+1) improvement for Hamiltonian parameter estimation on d-dimensional systems. We also show that, contrary to the conventional belief, it is possible to simultaneously achieve the highest precision for estimating all three components of a magnetic field, which sets a benchmark on the local precision limit for the estimation of a magnetic field.

  18. Sequential Combination of Electro-Fenton and Electrochemical Chlorination Processes for the Treatment of Anaerobically-Digested Food Wastewater.

    PubMed

    Shin, Yong-Uk; Yoo, Ha-Young; Kim, Seonghun; Chung, Kyung-Mi; Park, Yong-Gyun; Hwang, Kwang-Hyun; Hong, Seok Won; Park, Hyunwoong; Cho, Kangwoo; Lee, Jaesang

    2017-09-19

    A two-stage sequential electro-Fenton (E-Fenton) oxidation followed by electrochemical chlorination (EC) was demonstrated to concomitantly treat high concentrations of organic carbon and ammonium nitrogen (NH 4 + -N) in real anaerobically digested food wastewater (ADFW). The anodic Fenton process caused the rapid mineralization of phenol as a model substrate through the production of hydroxyl radical as the main oxidant. The electrochemical oxidation of NH 4 + by a dimensionally stable anode (DSA) resulted in temporal concentration profiles of combined and free chlorine species that were analogous to those during the conventional breakpoint chlorination of NH 4 + . Together with the minimal production of nitrate, this confirmed that the conversion of NH 4 + to nitrogen gas was electrochemically achievable. The monitoring of treatment performance with varying key parameters (e.g., current density, H 2 O 2 feeding rate, pH, NaCl loading, and DSA type) led to the optimization of two component systems. The comparative evaluation of two sequentially combined systems (i.e., the E-Fenton-EC system versus the EC-E-Fenton system) using the mixture of phenol and NH 4 + under the predetermined optimal conditions suggested the superiority of the E-Fenton-EC system in terms of treatment efficiency and energy consumption. Finally, the sequential E-Fenton-EC process effectively mineralized organic carbon and decomposed NH 4 + -N in the real ADFW without external supply of NaCl.

  19. Characterization of a high-pressure diesel fuel injection system as a control technology option to improve engine performance and reduce exhaust emissions

    NASA Technical Reports Server (NTRS)

    Mcfadden, J. J.; Dezelick, R. A.; Barrows, R. R.

    1983-01-01

    Test results from a high pressure electronically controlled fuel injection system are compared with a commercial mechanical injection system on a single cylinder, diesel test engine using an inlet boost pressure of 2.6:1. The electronic fuel injection system achieved high pressure by means of a fluid intensifier with peak injection pressures of 47 to 69 MPa. Reduced exhaust emissions were demonstrated with an increasing rate of injection followed by a fast cutoff of injection. The reduction in emissions is more responsive to the rate of injection and injection timing than to high peak injection pressure.

  20. Intratympanic Iodine Contrast Injection Diffuses Across the Round Window Membrane Allowing for Perilymphatic CT Volume Acquisition Imaging.

    PubMed

    Abt, Nicholas B; Lehar, Mohamed; Guajardo, Carolina Trevino; Penninger, Richard T; Ward, Bryan K; Pearl, Monica S; Carey, John P

    2016-04-01

    Whether the round window membrane (RWM) is permeable to iodine-based contrast agents (IBCA) is unknown; therefore, our goal was to determine if IBCAs could diffuse through the RWM using CT volume acquisition imaging. Imaging of hydrops in the living human ear has attracted recent interest. Intratympanic (IT) injection has shown gadolinium's ability to diffuse through the RWM, enhancing the perilymphatic space. Four unfixed human cadaver temporal bones underwent intratympanic IBCA injection using three sequentially studied methods. The first method was direct IT injection. The second method used direct RWM visualization via tympanomeatal flap for IBCA-soaked absorbable gelatin pledget placement. In the third method, the middle ear was filled with contrast after flap elevation. Volume acquisition CT images were obtained immediately postexposure, and at 1-, 6-, and 24-hour intervals. Postprocessing was accomplished using color ramping and subtraction imaging. After the third method, positive RWM and perilymphatic enhancement were observed with endolymph sparing. Gray scale and color ramp multiplanar reconstructions displayed increased signal within the cochlea compared with precontrast imaging. The cochlea was measured for attenuation differences compared with pure water, revealing a preinjection average of -1,103 HU and a postinjection average of 338 HU. Subtraction imaging shows enhancement remaining within the cochlear space, Eustachian tube, middle ear epithelial lining, and mastoid. Iohexol iodine contrast is able to diffuse across the RWM. Volume acquisition CT imaging was able to detect perilymphatic enhancement at 0.5-mm slice thickness. The clinical application of IBCA IT injection seems promising but requires further safety studies.

  1. Injection System for Multi-Well Injection Using a Single Pump

    PubMed Central

    Wovkulich, Karen; Stute, Martin; Protus, Thomas J.; Mailloux, Brian J.; Chillrud, Steven N.

    2015-01-01

    Many hydrological and geochemical studies rely on data resulting from injection of tracers and chemicals into groundwater wells. The even distribution of liquids to multiple injection points can be challenging or expensive, especially when using multiple pumps. An injection system was designed using one chemical metering pump to evenly distribute the desired influent simultaneously to 15 individual injection points through an injection manifold. The system was constructed with only one metal part contacting the fluid due to the low pH of the injection solutions. The injection manifold system was used during a three-month pilot scale injection experiment at the Vineland Chemical Company Superfund site. During the two injection phases of the experiment (Phase I = 0.27 L/min total flow, Phase II = 0.56 L/min total flow), flow measurements were made 20 times over three months; an even distribution of flow to each injection well was maintained (RSD <4%). This durable system is expandable to at least 16 injection points and should be adaptable to other injection experiments that require distribution of air-stable liquids to multiple injection points with a single pump. PMID:26140014

  2. Bioerodible System for Sequential Release of Multiple Drugs

    PubMed Central

    Sundararaj, Sharath C.; Thomas, Mark V.; Dziubla, Thomas D.; Puleo, David A.

    2013-01-01

    Because many complex physiological processes are controlled by multiple biomolecules, comprehensive treatment of certain disease conditions may be more effectively achieved by administration of more than one type of drug. Thus, the objective of the present research was to develop a multilayered, polymer-based system for sequential delivery of multiple drugs. The polymers used were cellulose acetate phthalate (CAP) complexed with Pluronic F-127 (P). After evaluating morphology of the resulting CAPP system, in vitro release of small molecule drugs and a model protein was studied from both single and multilayered devices. Drug release from single-layered CAPP films followed zero-order kinetics related to surface erosion of the association polymer. Release studies from multilayered CAPP devices showed the possibility of achieving intermittent release of one type of drug as well as sequential release of more than one type of drug. Mathematical modeling accurately predicted the release profiles for both single layer and multilayered devices. The present CAPP association polymer-based multilayer devices can be used for localized, sequential delivery of multiple drugs for the possible treatment of complex disease conditions, and perhaps for tissue engineering applications, that require delivery of more than one type of biomolecule. PMID:24096151

  3. Tolerability and immunogenicity of an inactivated enterovirus 71 vaccine in Chinese healthy adults and children: an open label, phase 1 clinical trial.

    PubMed

    Meng, Fan-Yue; Li, Jing-Xin; Li, Xiu-Ling; Chu, Kai; Zhang, Yun-Tao; Ji, Hong; Li, Liang; Liang, Zheng-Lun; Zhu, Feng-Cai

    2012-05-01

    In this open labeled phase 1 clinical trial with enterovirus 71 (EV71) vaccine (ClinicalTrials.gov number: NCT01267903) performed in Donghai County, Jiangsu Province, China, in January 2011. A total of 100 healthy participants, stratified by age (40 adults aged 16-22 y and 60 children aged 6-15 y), were enrolled from volunteers and sequentially received EV71 vaccines of 160U (only for children), 320U, or 640U on day 0 and 28, in a manner of dose escalation. All the participants were followed for 28 d after each shot. During the study period, 37 participants reported at least one injection-site or systemic adverse reaction. No case of grade 3 adverse reaction or serious adverse event (SAE) was observed. Also no dose-related increase in reaction rate was noticed. Pain at injection-site and fever were the most frequently reported local and systematic reaction, respectively. The studied EV71 vaccines demonstrated acceptable tolerability and no anti-nuclear antibody (ANA) seropositive was detected pre or post vaccinations in participants. Also, no clinically significant abnormal change for the liver or kidney function indexes was found. In the according-to-protocol cohort for immunogenicity, it was observed one dose of EV71 vaccine elicited good immune response in the participants, especially for the ones with sero-positive baseline. No obvious dose-response relationship for immunogenicity was found.

  4. Recombinant Temporal Aberration Detection Algorithms for Enhanced Biosurveillance

    PubMed Central

    Murphy, Sean Patrick; Burkom, Howard

    2008-01-01

    Objective Broadly, this research aims to improve the outbreak detection performance and, therefore, the cost effectiveness of automated syndromic surveillance systems by building novel, recombinant temporal aberration detection algorithms from components of previously developed detectors. Methods This study decomposes existing temporal aberration detection algorithms into two sequential stages and investigates the individual impact of each stage on outbreak detection performance. The data forecasting stage (Stage 1) generates predictions of time series values a certain number of time steps in the future based on historical data. The anomaly measure stage (Stage 2) compares features of this prediction to corresponding features of the actual time series to compute a statistical anomaly measure. A Monte Carlo simulation procedure is then used to examine the recombinant algorithms’ ability to detect synthetic aberrations injected into authentic syndromic time series. Results New methods obtained with procedural components of published, sometimes widely used, algorithms were compared to the known methods using authentic datasets with plausible stochastic injected signals. Performance improvements were found for some of the recombinant methods, and these improvements were consistent over a range of data types, outbreak types, and outbreak sizes. For gradual outbreaks, the WEWD MovAvg7+WEWD Z-Score recombinant algorithm performed best; for sudden outbreaks, the HW+WEWD Z-Score performed best. Conclusion This decomposition was found not only to yield valuable insight into the effects of the aberration detection algorithms but also to produce novel combinations of data forecasters and anomaly measures with enhanced detection performance. PMID:17947614

  5. Automatic sequential fluid handling with multilayer microfluidic sample isolated pumping

    PubMed Central

    Liu, Jixiao; Fu, Hai; Yang, Tianhang; Li, Songjing

    2015-01-01

    To sequentially handle fluids is of great significance in quantitative biology, analytical chemistry, and bioassays. However, the technological options are limited when building such microfluidic sequential processing systems, and one of the encountered challenges is the need for reliable, efficient, and mass-production available microfluidic pumping methods. Herein, we present a bubble-free and pumping-control unified liquid handling method that is compatible with large-scale manufacture, termed multilayer microfluidic sample isolated pumping (mμSIP). The core part of the mμSIP is the selective permeable membrane that isolates the fluidic layer from the pneumatic layer. The air diffusion from the fluidic channel network into the degassing pneumatic channel network leads to fluidic channel pressure variation, which further results in consistent bubble-free liquid pumping into the channels and the dead-end chambers. We characterize the mμSIP by comparing the fluidic actuation processes with different parameters and a flow rate range of 0.013 μl/s to 0.097 μl/s is observed in the experiments. As the proof of concept, we demonstrate an automatic sequential fluid handling system aiming at digital assays and immunoassays, which further proves the unified pumping-control and suggests that the mμSIP is suitable for functional microfluidic assays with minimal operations. We believe that the mμSIP technology and demonstrated automatic sequential fluid handling system would enrich the microfluidic toolbox and benefit further inventions. PMID:26487904

  6. Human sympathetic and vagal baroreflex responses to sequential nitroprusside and phenylephrine

    NASA Technical Reports Server (NTRS)

    Rudas, L.; Crossman, A. A.; Morillo, C. A.; Halliwill, J. R.; Tahvanainen, K. U.; Kuusela, T. A.; Eckberg, D. L.

    1999-01-01

    We evaluated a method of baroreflex testing involving sequential intravenous bolus injections of nitroprusside followed by phenylephrine and phenylephrine followed by nitroprusside in 18 healthy men and women, and we drew inferences regarding human sympathetic and vagal baroreflex mechanisms. We recorded the electrocardiogram, photoplethysmographic finger arterial pressure, and peroneal nerve muscle sympathetic activity. We then contrasted least squares linear regression slopes derived from the depressor (nitroprusside) and pressor (phenylephrine) phases with 1) slopes derived from spontaneous fluctuations of systolic arterial pressures and R-R intervals, and 2) baroreflex gain derived from cross-spectral analyses of systolic pressures and R-R intervals. We calculated sympathetic baroreflex gain from integrated muscle sympathetic nerve activity and diastolic pressures. We found that vagal baroreflex slopes are less when arterial pressures are falling than when they are rising and that this hysteresis exists over pressure ranges both below and above baseline levels. Although pharmacological and spontaneous vagal baroreflex responses correlate closely, pharmacological baroreflex slopes tend to be lower than those derived from spontaneous fluctuations. Sympathetic baroreflex slopes are similar when arterial pressure is falling and rising; however, small pressure elevations above baseline silence sympathetic motoneurons. Vagal, but not sympathetic baroreflex gains vary inversely with subjects' ages and their baseline arterial pressures. There is no correlation between sympathetic and vagal baroreflex gains. We recommend repeated sequential nitroprusside followed by phenylephrine doses as a simple, efficientmeans to provoke and characterize human vagal and sympathetic baroreflex responses.

  7. Hydraulic Fracture Induced Seismicity During A Multi-Stage Pad Completion in Western Canada: Evidence of Activation of Multiple, Parallel Faults

    NASA Astrophysics Data System (ADS)

    Maxwell, S.; Garrett, D.; Huang, J.; Usher, P.; Mamer, P.

    2017-12-01

    Following reports of injection induced seismicity in the Western Canadian Sedimentary Basin, regulators have imposed seismic monitoring and traffic light protocols for fracturing operations in specific areas. Here we describe a case study in one of these reservoirs, the Montney Shale in NE British Columbia, where induced seismicity was monitored with a local array during multi-stage hydraulic fracture stimulations on several wells from a single drilling pad. Seismicity primarily occurred during the injection time periods, and correlated with periods of high injection rates and wellhead pressures above fracturing pressures. Sequential hydraulic fracture stages were found to progressively activate several parallel, critically-stressed faults, as illuminated by multiple linear hypocenter patterns in the range between Mw 1 and 3. Moment tensor inversion of larger events indicated a double-couple mechanism consistent with the regional strike-slip stress state and the hypocenter lineations. The critically-stressed faults obliquely cross the well paths which were purposely drilled parallel to the minimum principal stress direction. Seismicity on specific faults started and stopped when fracture initiation points of individual injection stages were proximal to the intersection of the fault and well. The distance ranges when the seismicity occurs is consistent with expected hydraulic fracture dimensions, suggesting that the induced fault slip only occurs when a hydraulic fracture grows directly into the fault and the faults are temporarily exposed to significantly elevated fracture pressures during the injection. Some faults crossed multiple wells and the seismicity was found to restart during injection of proximal stages on adjacent wells, progressively expanding the seismogenic zone of the fault. Progressive fault slip is therefore inferred from the seismicity migrating further along the faults during successive injection stages. An accelerometer was also deployed close to the pad operations providing information about the local ground motion at near offsets, although no ground motion was recorded that exceeds the minimum levels requiring mandatory reporting to the regulator.

  8. PARTICLE FILTERING WITH SEQUENTIAL PARAMETER LEARNING FOR NONLINEAR BOLD fMRI SIGNALS.

    PubMed

    Xia, Jing; Wang, Michelle Yongmei

    Analyzing the blood oxygenation level dependent (BOLD) effect in the functional magnetic resonance imaging (fMRI) is typically based on recent ground-breaking time series analysis techniques. This work represents a significant improvement over existing approaches to system identification using nonlinear hemodynamic models. It is important for three reasons. First, instead of using linearized approximations of the dynamics, we present a nonlinear filtering based on the sequential Monte Carlo method to capture the inherent nonlinearities in the physiological system. Second, we simultaneously estimate the hidden physiological states and the system parameters through particle filtering with sequential parameter learning to fully take advantage of the dynamic information of the BOLD signals. Third, during the unknown static parameter learning, we employ the low-dimensional sufficient statistics for efficiency and avoiding potential degeneration of the parameters. The performance of the proposed method is validated using both the simulated data and real BOLD fMRI data.

  9. Comparison between variable and fixed dwell-time PN acquisition algorithms. [for synchronization in pseudonoise spread spectrum systems

    NASA Technical Reports Server (NTRS)

    Braun, W. R.

    1981-01-01

    Pseudo noise (PN) spread spectrum systems require a very accurate alignment between the PN code epochs at the transmitter and receiver. This synchronism is typically established through a two-step algorithm, including a coarse synchronization procedure and a fine synchronization procedure. A standard approach for the coarse synchronization is a sequential search over all code phases. The measurement of the power in the filtered signal is used to either accept or reject the code phase under test as the phase of the received PN code. This acquisition strategy, called a single dwell-time system, has been analyzed by Holmes and Chen (1977). A synopsis of the field of sequential analysis as it applies to the PN acquisition problem is provided. From this, the implementation of the variable dwell time algorithm as a sequential probability ratio test is developed. The performance of this algorithm is compared to the optimum detection algorithm and to the fixed dwell-time system.

  10. Synthetic progestins induce growth and metastasis of BT-474 human breast cancer xenografts in nude mice

    PubMed Central

    Liang, Yayun; Benakanakere, Indira; Besch-Williford, Cynthia; Hyder, Ryyan S; Ellersieck, Mark R.; Hyder, Salman M

    2010-01-01

    Objective Previous studies showed that sequential exposure to estrogen and progesterone or medroxyprogesterone acetate (MPA) stimulates vascularization and promotes the progression of BT-474 and T47-D human breast cancer cell xenografts in nude mice (Liang et al, Cancer Res 2007, 67:9929). In this follow-up study, the effects of progesterone, MPA, norgestrel (N-EL) and norethindrone (N-ONE) on BT-474 xenograft tumors were compared in the context of several different hormonal environments. N-EL and N-ONE were included in the study since synthetic progestins vary considerably in their biological effects and the effects of these two progestins on the growth of human tumor xenografts are not known. Methods Estradiol-supplemented intact and ovariectomized Immunodeficient mice were implanted with BT-474 cells. Progestin pellets were implanted either simultaneously with estradiol pellets 2-days prior to tumor cell injection (i.e. combined), or 5-days following tumor cell injections (i.e. sequentially). Results Progestins stimulated the growth of BT-474 xenograft tumors independent of exposure timing and protocol, MPA stimulated the growth of BT-474 xenograft tumors in ovariectomized mice and progestins stimulated VEGF elaboration and increased tumor vascularity. Progestins also increased lymph node metastasis of BT-474 cells. Therefore, progestins, including N-EL and N-ONE, induce the progression of breast cancer xenografts in nude mice and promote tumor metastasis. Conclusions These observations suggests that women who ingest progestins for HT or oral contraception could be more at risk for developing breast cancer as a result of proliferation of existing latent tumor cells. Such risks should be considered in the clinical setting. PMID:20461021

  11. On-line hyphenation of solid-phase extraction to chromatographic separation of sulfonamides with fused-core columns in sequential injection chromatography.

    PubMed

    Batista, Alex D; Chocholouš, Petr; Satínský, Dalibor; Solich, Petr; Rocha, Fábio R P

    2015-02-01

    On-line sample pretreatment (clean-up and analyte preconcentration) is for the first time coupled to sequential injection chromatography. The approach combines anion-exchange solid-phase extraction and the highly effective pentafluorophenylpropyl (F5) fused-core particle column for separation of eight sulfonamide antibiotics with similar structures (sulfathiazole, sulfanilamide, sulfacetamide, sulfadiazine, sulfamerazine, sulfadimidine, sulfamethoxazole and sulfadimethoxine). The stationary phase was selected after a critical comparison of the performance achieved by three fused-core reversed phase columns (Ascentis(®) Express RP-Amide, Phenyl-Hexyl, and F5) and two monolithic columns (Chromolith(®) High Resolution RP-18 and CN). Acetonitrile and acetate buffer pH 5.0 at 0.60 mL min(-1) were used as mobile phase to perform the separations before spectrophotometric detection. The first mobile phase was successfully used as eluent from SPE column ensuring transfer of a narrow zone to the chromatographic column. Enrichment factors up to 39.2 were achieved with a 500 µL sample volume. The developed procedure showed analysis time <10.5 min, resolutions >1.83 with peak symmetry ≤1.52, LODs between 4.9 and 27 µg L(-1), linear response ranges from 30.0 to 1000.0 µg L(-1) (r(2)>0.996) and RSDs of peak heights <2.9% (n=6) at a 100 µg L(-1) level and enabled the screening control of freshwater samples contaminated at the 100 µg L(-1) level. The proposed approach expanded the analytical potentiality of SIC and avoided the time-consuming batch sample pretreatment step, thus minimizing risks of sample contamination and analyte losses. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Concomitant or sequential administration of live attenuated Japanese encephalitis chimeric virus vaccine and yellow fever 17D vaccine: randomized double-blind phase II evaluation of safety and immunogenicity.

    PubMed

    Nasveld, Peter E; Marjason, Joanne; Bennett, Sonya; Aaskov, John; Elliott, Suzanne; McCarthy, Karen; Kanesa-Thasan, Niranjan; Feroldi, Emmanuel; Reid, Mark

    2010-11-01

    A randomized, double-blind, study was conducted to evaluate the safety, tolerability and immunogenicity of a live attenuated Japanese encephalitis chimeric virus vaccine (JE-CV) co-administered with live attenuated yellow fever vaccine (YF-17D strain; Stamaril®, Sanofi Pasteur) or administered successively. Participants (n = 108) were randomized to receive: YF followed by JE-CV 30 days later, JE followed by YF 30 days later, or the co-administration of JE and YF followed or preceded by placebo 30 days later or earlier. Placebo was used in a double-dummy fashion to ensure masking. Neutralizing antibody titers against JE-CV, YF-17D and selected wild-type JE strains was determined using a 50% serum-dilution plaque reduction neutralization test. Seroconversion was defined as the appearance of a neutralizing antibody titer above the assay cut-off post-immunization when not present pre-injection at day 0, or a least a four-fold rise in neutralizing antibody titer measured before the pre-injection day 0 and later post vaccination samples. There were no serious adverse events. Most adverse events (AEs) after JE vaccination were mild to moderate in intensity, and similar to those reported following YF vaccination. Seroconversion to JE-CV was 100% and 91% in the JE/YF and YF/JE sequential vaccination groups, respectively, compared with 96% in the co-administration group. All participants seroconverted to YF vaccine and retained neutralizing titers above the assay cut-off at month six. Neutralizing antibodies against JE vaccine were detected in 82-100% of participants at month six. These results suggest that both vaccines may be successfully co-administered simultaneously or 30 days apart.

  13. Fully automated analytical procedure for propofol determination by sequential injection technique with spectrophotometric and fluorimetric detections.

    PubMed

    Šrámková, Ivana; Amorim, Célia G; Sklenářová, Hana; Montenegro, Maria C B M; Horstkotte, Burkhard; Araújo, Alberto N; Solich, Petr

    2014-01-01

    In this work, an application of an enzymatic reaction for the determination of the highly hydrophobic drug propofol in emulsion dosage form is presented. Emulsions represent a complex and therefore challenging matrix for analysis. Ethanol was used for breakage of a lipid emulsion, which enabled optical detection. A fully automated method based on Sequential Injection Analysis was developed, allowing propofol determination without the requirement of tedious sample pre-treatment. The method was based on spectrophotometric detection after the enzymatic oxidation catalysed by horseradish peroxidase and subsequent coupling with 4-aminoantipyrine leading to a coloured product with an absorbance maximum at 485 nm. This procedure was compared with a simple fluorimetric method, which was based on the direct selective fluorescence emission of propofol in ethanol at 347 nm. Both methods provide comparable validation parameters with linear working ranges of 0.005-0.100 mg mL(-1) and 0.004-0.243 mg mL(-1) for the spectrophotometric and fluorimetric methods, respectively. The detection and quantitation limits achieved with the spectrophotometric method were 0.0016 and 0.0053 mg mL(-1), respectively. The fluorimetric method provided the detection limit of 0.0013 mg mL(-1) and limit of quantitation of 0.0043 mg mL(-1). The RSD did not exceed 5% and 2% (n=10), correspondingly. A sample throughput of approx. 14 h(-1) for the spectrophotometric and 68 h(-1) for the fluorimetric detection was achieved. Both methods proved to be suitable for the determination of propofol in pharmaceutical formulation with average recovery values of 98.1 and 98.5%. © 2013 Elsevier B.V. All rights reserved.

  14. The Dependency in the Elasticity of the Saccharomyces cerevisiae Cell Wall upon Cell Viability and Membrane Integrity

    NASA Astrophysics Data System (ADS)

    McPherson, Dacia; Zhu, Chenhui; Yi, Youngwoo; Clark, Noel

    2007-03-01

    In this study the elastic spring constant of the yeast cell wall is probed with the atomic force microscope (AFM) under variable conditions. Cells were sequentially analyzed in rich growth medium (YPD), a 0.8 M NaCl rich growth medium solution and an injection of 0.01% sodium azide solution. Cells in late log phase, which have variable diameters within three to five microns, were immobilized on a patterned silicon substrate with holes approximately 3.8um in diameter and 1.5um deep that was functionalized with polyethylenimine prior to cell application. Force curves were taken moving laterally across the cell in one dimension after exposure to each medium. Spring constants of the cells, calculated from force curves, displayed a positional dependency and marked differences in high osmolarity medium and after the injection of sodium azide. This study demonstrates the ability of the AFM to investigate changes in cell morphology and correlate those findings to underlying physiological processes.

  15. EMC3-EIRENE modelling of toroidally-localized divertor gas injection experiments on Alcator C-Mod

    DOE PAGES

    Lore, Jeremy D.; Reinke, M. L.; LaBombard, Brian; ...

    2014-09-30

    Experiments on Alcator C-Mod with toroidally and poloidally localized divertor nitrogen injection have been modeled using the three-dimensional edge transport code EMC3-EIRENE to elucidate the mechanisms driving measured toroidal asymmetries. In these experiments five toroidally distributed gas injectors in the private flux region were sequentially activated in separate discharges resulting in clear evidence of toroidal asymmetries in radiated power and nitrogen line emission as well as a ~50% toroidal modulation in electron pressure at the divertor target. The pressure modulation is qualitatively reproduced by the modelling, with the simulation yielding a toroidal asymmetry in the heat flow to the outermore » strike point. Finally, toroidal variation in impurity line emission is qualitatively matched in the scrape-off layer above the strike point, however kinetic corrections and cross-field drifts are likely required to quantitatively reproduce impurity behavior in the private flux region and electron temperatures and densities directly in front of the target.« less

  16. A meta-analysis of response-time tests of the sequential two-systems model of moral judgment.

    PubMed

    Baron, Jonathan; Gürçay, Burcu

    2017-05-01

    The (generalized) sequential two-system ("default interventionist") model of utilitarian moral judgment predicts that utilitarian responses often arise from a system-two correction of system-one deontological intuitions. Response-time (RT) results that seem to support this model are usually explained by the fact that low-probability responses have longer RTs. Following earlier results, we predicted response probability from each subject's tendency to make utilitarian responses (A, "Ability") and each dilemma's tendency to elicit deontological responses (D, "Difficulty"), estimated from a Rasch model. At the point where A = D, the two responses are equally likely, so probability effects cannot account for any RT differences between them. The sequential two-system model still predicts that many of the utilitarian responses made at this point will result from system-two corrections of system-one intuitions, hence should take longer. However, when A = D, RT for the two responses was the same, contradicting the sequential model. Here we report a meta-analysis of 26 data sets, which replicated the earlier results of no RT difference overall at the point where A = D. The data sets used three different kinds of moral judgment items, and the RT equality at the point where A = D held for all three. In addition, we found that RT increased with A-D. This result holds for subjects (characterized by Ability) but not for items (characterized by Difficulty). We explain the main features of this unanticipated effect, and of the main results, with a drift-diffusion model.

  17. INVESTIGATION OF SEQUENTIAL AND ENZYMATIC EXTRACTION OF ARSENIC FROM DRINKING WATER DISTRIBUTION SOLIDS WITH ICP-MS

    EPA Science Inventory

    A sequential extraction approach was utilized to estimate the distribution of arsenite [As(III)] and arsenate [As(V)] on iron oxide/hydroxide solids obtained from drinking water distribution systems. The arsenic (As) associated with these solids can be segregated into three oper...

  18. Combining silver- and organocatalysis: an enantioselective sequential catalytic approach towards pyrano-annulated pyrazoles.

    PubMed

    Hack, Daniel; Chauhan, Pankaj; Deckers, Kristina; Mizutani, Yusuke; Raabe, Gerhard; Enders, Dieter

    2015-02-11

    A one-pot asymmetric Michael addition/hydroalkoxylation sequence, catalyzed by a sequential catalytic system consisting of a squaramide and a silver salt, provides a new series of chiral pyrano-annulated pyrazole derivatives in excellent yields (up to 95%) and high enantioselectivities (up to 97% ee).

  19. J-adaptive estimation with estimated noise statistics

    NASA Technical Reports Server (NTRS)

    Jazwinski, A. H.; Hipkins, C.

    1973-01-01

    The J-adaptive sequential estimator is extended to include simultaneous estimation of the noise statistics in a model for system dynamics. This extension completely automates the estimator, eliminating the requirement of an analyst in the loop. Simulations in satellite orbit determination demonstrate the efficacy of the sequential estimation algorithm.

  20. S.M.P. SEQUENTIAL MATHEMATICS PROGRAM.

    ERIC Educational Resources Information Center

    CICIARELLI, V; LEONARD, JOSEPH

    A SEQUENTIAL MATHEMATICS PROGRAM BEGINNING WITH THE BASIC FUNDAMENTALS ON THE FOURTH GRADE LEVEL IS PRESENTED. INCLUDED ARE AN UNDERSTANDING OF OUR NUMBER SYSTEM, AND THE BASIC OPERATIONS OF WORKING WITH WHOLE NUMBERS--ADDITION, SUBTRACTION, MULTIPLICATION, AND DIVISION. COMMON FRACTIONS ARE TAUGHT IN THE FIFTH, SIXTH, AND SEVENTH GRADES. A…

  1. An investigation of the performance of an electronic in-line pump system for diesel engines

    NASA Astrophysics Data System (ADS)

    Fan, Li-Yun; Zhu, Yuan-Xian; Long, Wu-Qiang; Ma, Xiu-Zhen; Xue, Ying-Ying

    2008-12-01

    WIT Electronic Fuel System Co., Ltd. has developed a new fuel injector, the Electronic In-line Pump (EIP) system, designed to meet China’s diesel engine emission and fuel economy regulations. It can be used on marine diesel engines and commercial vehicle engines through different EIP systems. A numerical model of the EIP system was built in the AMESim environment for the purpose of creating a design tool for engine application and system optimization. The model was used to predict key injection characteristics under different operating conditions, such as injection pressure, injection rate, and injection duration. To validate these predictions, experimental tests were conducted under the conditions that were modeled. The results were quite encouraging and in agreement with model predictions. Additional experiments were conducted to study the injection characteristics of the EIP system. These results show that injection pressure and injection quantity are insensitive to injection timing variations, this is due to the design of the constant velocity cam profile. Finally, injection quantity and pressure vs. pulse width at different cam speeds are presented, an important injection characteristic for EIP system calibration.

  2. Features of computerized clinical decision support systems supportive of nursing practice: a literature review.

    PubMed

    Lee, Seonah

    2013-10-01

    This study aimed to organize the system features of decision support technologies targeted at nursing practice into assessment, problem identification, care plans, implementation, and outcome evaluation. It also aimed to identify the range of the five stage-related sequential decision supports that computerized clinical decision support systems provided. MEDLINE, CINAHL, and EMBASE were searched. A total of 27 studies were reviewed. The system features collected represented the characteristics of each category from patient assessment to outcome evaluation. Several features were common across the reviewed systems. For the sequential decision support, all of the reviewed systems provided decision support in sequence for patient assessment and care plans. Fewer than half of the systems included problem identification. There were only three systems operating in an implementation stage and four systems in outcome evaluation. Consequently, the key steps for sequential decision support functions were initial patient assessment, problem identification, care plan, and outcome evaluation. Providing decision support in such a full scope will effectively help nurses' clinical decision making. By organizing the system features, a comprehensive picture of nursing practice-oriented computerized decision support systems was obtained; however, the development of a guideline for better systems should go beyond the scope of a literature review.

  3. Sequential growth for lifetime extension in biomimetic polypyrrole actuator systems

    NASA Astrophysics Data System (ADS)

    Sarrazin, J. C.; Mascaro, Stephen A.

    2015-04-01

    Electroactive polymers (EAPs) present prospective use in actuation and manipulation devices due to their low electrical activation requirements, biocompatibility, and mechanical performance. One of the main drawbacks with EAP actuators is a decrease in performance over extended periods of operation caused by over-oxidation of the polymer and general polymer degradation. Synthesis of the EAP material, polypyrrole with an embedded metal helix allows for sequential growth of the polymer during operation. The helical metal electrode acts as a scaffolding to support the polymer, and direct the 3-dimensional change in volume of the polymer along the axis of the helix during oxidative and reductive cycling. The metal helix also provides a working metal electrode through the entire length of the polymer actuator to distribute charge for actuation, as well as for sequential growth steps during the lifetime of operation of the polymer. This work demonstrates the method of sequential growth can be utilized after extended periods of use to partially restore electrical and mechanical performance of polypyrrole actuators. Since the actuation must be temporarily stopped to allow for a sequential growth cycle to be performed and reverse some of the polymer degradation, these actuator systems more closely mimic natural muscle in their analogous maintenance and repair.

  4. Multi-point objective-oriented sequential sampling strategy for constrained robust design

    NASA Astrophysics Data System (ADS)

    Zhu, Ping; Zhang, Siliang; Chen, Wei

    2015-03-01

    Metamodelling techniques are widely used to approximate system responses of expensive simulation models. In association with the use of metamodels, objective-oriented sequential sampling methods have been demonstrated to be effective in balancing the need for searching an optimal solution versus reducing the metamodelling uncertainty. However, existing infilling criteria are developed for deterministic problems and restricted to one sampling point in one iteration. To exploit the use of multiple samples and identify the true robust solution in fewer iterations, a multi-point objective-oriented sequential sampling strategy is proposed for constrained robust design problems. In this article, earlier development of objective-oriented sequential sampling strategy for unconstrained robust design is first extended to constrained problems. Next, a double-loop multi-point sequential sampling strategy is developed. The proposed methods are validated using two mathematical examples followed by a highly nonlinear automotive crashworthiness design example. The results show that the proposed method can mitigate the effect of both metamodelling uncertainty and design uncertainty, and identify the robust design solution more efficiently than the single-point sequential sampling approach.

  5. Generating finite cyclic and dihedral groups using sequential insertion systems with interactions

    NASA Astrophysics Data System (ADS)

    Fong, Wan Heng; Sarmin, Nor Haniza; Turaev, Sherzod; Yosman, Ahmad Firdaus

    2017-04-01

    The operation of insertion has been studied extensively throughout the years for its impact in many areas of theoretical computer science such as DNA computing. First introduced as a generalization of the concatenation operation, many variants of insertion have been introduced, each with their own computational properties. In this paper, we introduce a new variant that enables the generation of some special types of groups called sequential insertion systems with interactions. We show that these new systems are able to generate all finite cyclic and dihedral groups.

  6. Nanoparticle bioconjugates as "bottom-up" assemblies of artifical multienzyme complexes

    NASA Astrophysics Data System (ADS)

    Keighron, Jacqueline D.

    2010-11-01

    The sequential enzymes of several metabolic pathways have been shown to exist in close proximity with each other in the living cell. Although not proven in all cases, colocalization may have several implications for the rate of metabolite formation. Proximity between the sequential enzymes of a metabolic pathway has been proposed to have several benefits for the overall rate of metabolite formation. These include reduced diffusion distance for intermediates, sequestering of intermediates from competing pathways and the cytoplasm. Restricted diffusion in the vicinity of an enzyme can also cause the pooling of metabolites, which can alter reaction equilibria to control the rate of reaction through inhibition. Associations of metabolic enzymes are difficult to isolate ex vivo due to the weak interactions believed to colocalize sequential enzymes within the cell. Therefore model systems in which the proximity and diffusion of intermediates within the experiment system are controlled are attractive alternatives to explore the effects of colocalization of sequential enzymes. To this end three model systems for multienzyme complexes have been constructed. Direct adsorption enzyme:gold nanoparticle bioconjugates functionalized with malate dehydrogenase (MDH) and citrate synthase (CS) allow for proximity between to the enzymes to be controlled from the nanometer to micron range. Results show that while the enzymes present in the colocalized and non-colocalized systems compared here behaved differently overall the sequential activity of the pathway was improved by (1) decreasing the diffusion distance between active sites, (2) decreasing the diffusion coefficient of the reaction intermediate to prevent escape into the bulk solution, and (3) decreasing the overall amount of bioconjugate in the solution to prevent the pathway from being inhibited by the buildup of metabolite over time. Layer-by-layer (LBL) assemblies of MDH and CS were used to examine the layering effect of sequential enzymes found in multienzyme complexes such as the pyruvate dehydrogenase complex (PDC). By controlling the orientation of enzymes in the complex (i.e. how deeply embedded each enzyme is) it was hypothesized that differences in sequential activity would determine an optimal orientation for a multienzyme complex. It was determined during the course of these experiments that the polyelectrolyte (PE) assembly itself served to slow diffusion of intermediates, leading to a buildup of oxaloacetate within the PE layers to form a pool of metabolite that equalized the rate of sequential reaction between the different orientations tested. Hexahistidine tag -- Ni(II) nitriliotriacetic acid (NTA) chemistry is an attractive method to control the proximity between sequential enzymes because each enzyme can be bound in a specific orientation, with minimal loss of activity, and the interaction is reversible. Modifying gold nanoparticles or large unilamellar vesicles with this functionality allows for another class of model to be constructed in which proximity between enzymes is dynamic. Some metabolic pathways (such as the de novo purine biosynthetic pathway), have demonstrated dynamic proximity of sequential enzymes in response to specific cellular stimuli. Results indicate that Ni(II)NTA scaffolds immobilize histidine-tagged enzymes non-destructively, with a near 100% reversibility. This model can be used to demonstrate the possible implications of dynamic proximity such as pathway regulation. Insight into the benefits and mechanisms of sequential enzyme colocalization can enhance the general understanding of cellular processes, as well as allow for the development of new and innovative ways to modulate pathway activity. This may provide new designs for treatments of metabolic diseases and cancer, where metabolic pathways are altered.

  7. Portable low-cost devices for videotaping, editing, and displaying field-sequential stereoscopic motion pictures and video

    NASA Astrophysics Data System (ADS)

    Starks, Michael R.

    1990-09-01

    A variety of low cost devices for capturing, editing and displaying field sequential 60 cycle stereoscopic video have recently been marketed by 3D TV Corp. and others. When properly used, they give very high quality images with most consumer and professional equipment. Our stereoscopic multiplexers for creating and editing field sequential video in NTSC or component(SVHS, Betacain, RGB) and Home 3D Theater system employing LCD eyeglasses have made 3D movies and television available to a large audience.

  8. 64 slice MDCT generally underestimates coronary calcium scores as compared to EBT: A phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greuter, M. J. W.; Dijkstra, H.; Groen, J. M.

    The objective of our study was the determination of the influence of the sequential and spiral acquisition modes on the concordance and deviation of the calcium score on 64-slice multi-detector computed tomography (MDCT) scanners in comparison to electron beam tomography (EBT) as the gold standard. Our methods and materials were an anthropomorphic cardio CT phantom with different calcium inserts scanned in sequential and spiral acquisition modes on three identical 64-slice MDCT scanners of manufacturer A and on three identical 64-slice MDCT scanners of manufacturer B and on an EBT system. Every scan was repeated 30 times with and 15 timesmore » without a small random variation in the phantom position for both sequential and spiral modes. Significant differences were observed between EBT and 64-slice MDCT data for all inserts, both acquisition modes, and both manufacturers of MDCT systems. High regression coefficients (0.90-0.98) were found between the EBT and 64-slice MDCT data for both scoring methods and both systems with high correlation coefficients (R{sup 2}>0.94). System A showed more significant differences between spiral and sequential mode than system B. Almost no differences were observed in scanners of the same manufacturer for the Agatston score and no differences for the Volume score. The deviations of the Agatston and Volume scores showed regression dependencies approximately equal to the square root of the absolute score. The Agatston and Volume scores obtained with 64-slice MDCT imaging are highly correlated with EBT-obtained scores but are significantly underestimated (-10% to -2%) for both sequential and spiral acquisition modes. System B is more independent of acquisition mode to calcium score than system A. The Volume score shows no intramanufacturer dependency and its use is advocated versus the Agatston score. Using the same cut points for MDCT-based calcium scores as for EBT-based calcium scores can result in classifying individuals into a too low risk category. System information and scanprotocol is therefore needed for every calcium score procedure to ensure a correct clinical interpretation of the obtained calcium score results.« less

  9. The effectiveness of a mail reminder system for depot medroxyprogesterone injections.

    PubMed

    Madlon-Kay, D J

    1996-04-01

    To determine if a mail reminder system leads to an increase in the percentage of depot medroxyprogesterone acetate (Depo-Provera) injections administered on time, the charts of 184 women were reviewed. The reminder postcard included the due dates of both the next medroxyprogesterone injection and the next Papanicolaou test. Timeliness of injections improved with the reminder system from 64% administered on time to 76% (P < .02). Injections given late despite the reminders were late a mean of 8 days. Injections given late before the reminder system began were late a mean of 20 days (P < .05). If injections given during the injection's 14-day "grace" period are included, the on-time rate improved from 87% to 96% with the reminder system (P < .005). The reminder system was not effective in ensuring annual Papanicolaou testing. Vigilance is needed to ensure that women receiving medroxyprogesterone injections also receive timely Papanicolaou testing.

  10. A volumetric flow sensor for automotive injection systems

    NASA Astrophysics Data System (ADS)

    Schmid, U.; Krötz, G.; Schmitt-Landsiedel, D.

    2008-04-01

    For further optimization of the automotive power train of diesel engines, advanced combustion processes require a highly flexible injection system, provided e.g. by the common rail (CR) injection technique. In the past, the feasibility to implement injection nozzle volumetric flow sensors based on the thermo-resistive measurement principle has been demonstrated up to injection pressures of 135 MPa (1350 bar). To evaluate the transient behaviour of the system-integrated flow sensors as well as an injection amount indicator used as a reference method, hydraulic simulations on the system level are performed for a CR injection system. Experimentally determined injection timings were found to be in good agreement with calculated values, especially for the novel sensing element which is directly implemented into the hydraulic system. For the first time pressure oscillations occurring after termination of the injection pulse, predicted theoretically, could be verified directly in the nozzle. In addition, the injected amount of fuel is monitored with the highest resolution ever reported in the literature.

  11. Rates of fuel discharge as affected by the design of fuel-injection systems for internal-combustion engines

    NASA Technical Reports Server (NTRS)

    Gelalles, A G; Marsh, E T

    1933-01-01

    Using the method of weighing fuel collected in a receiver during a definite interval of the injection period, rates of discharge were determined, and the effects noted, when various changes were made in a fuel-injection system. The injection system consisted primarily of a by-pass controlled fuel pump and an automatic injection valve. The variables of the system studied were the pump speed, pump-throttle setting, discharge-orifice diameter, injection-valve opening and closing pressures, and injection-tube length and diameter.

  12. Dose-dependent biodistribution of prenatal exposure to rutile-type titanium dioxide nanoparticles on mouse testis

    NASA Astrophysics Data System (ADS)

    Kubo-Irie, Miyoko; Uchida, Hiroki; Mastuzawa, Shotaro; Yoshida, Yasuko; Shinkai, Yusuke; Suzuki, Kenichiro; Yokota, Satoshi; Oshio, Shigeru; Takeda, Ken

    2014-02-01

    Titanium dioxide nanoparticles (nano-TiO2), believed to be inert and safe, are used in many products especially rutile-type in cosmetics. Detection, localization, and count of nanoparticles in tissue sections are of considerable current interest. Here, we evaluate the dose-dependent biodistribution of rutile-type nano-TiO2 exposure during pregnancy on offspring testes. Pregnant mice were subcutaneously injected five times with 0.1 ml of sequentially diluted of nano-TiO2 powder, 35 nm with primary diameter, suspensions (1, 10, 100, or 1,000 μg/ml), and received total doses of 0.5, 5, 50, and 500 μg, respectively. Prior to injection, the size distribution of nano-TiO2 was analyzed by dynamic light scattering measurement. The average diameter was increased in a dose-dependent manner. The most diluted concentration, 1 μg/ml suspension, contained small agglomerates averaging 193.3 ± 5.4 nm in diameter. The offspring testes were examined at 12 weeks postpartum. Individual particle analysis in testicular sections under scanning and transmission electron microscopy enabled us to understand the biodistribution. The correlation between nano-TiO2 doses injected to pregnant mice, and the number of agglomerates in the offspring testes was demonstrated to be dose-dependent by semiquantitative evaluation. However, the agglomerate size was below 200 nm in the testicular sections of all recipient groups, independent from the injected dose during pregnancy.

  13. Superparamagnetic And Paramagnetic MRI Contrast Agents: Application Of Rapid Magnetic Resonance Imaging To Assess Renal Function

    NASA Astrophysics Data System (ADS)

    Carvlin, Mark J.; Renshaw, Perry F.; Arger, Peter; Kundel, Harold L.; Dougherty, Larry; Axel, Leon; Kassab, Eleanor; Moore, Bethanne

    1988-06-01

    The paramagnetic chelate complex, gadolinium-diethylene-triamine-pentaacetic acid, Gd-DTPA, and superparamagnetic particles, such as those composed of dextran coated magnetite, function as magnetic resonance contrast agents by changing the relaxation rates, 1/T1 and 1/T2. The effects that these agents have upon MR signal intensity are determined by: the inherent biophysical properties of the tissue being imaged, the concentration of the contrast agent and the data acquisition scheme (pulse sequence parameters) employed. Following the time course of MR signal change in the first minutes after the injection of contrast agent(s) allows a dynamic assessment of organ functions in a manner analogous to certain nuclear medicine studies. In order to study renal function, sequential MR fast scan images, gradient echo (TR=35/TE=7 msec, flip angle=25 degrees), were acquired, one every 12 seconds, after intravenous injection of Gd-DTPA and/or dextran-magnetite. Gd-DTPA, which is freely filtered at the glomerulus and is neither secreted nor reabsorbed, provides information concerning renal perfusion, glomerular filtration and tubular concentrating ability. Dextran-magnetite (200 A diameter), which is primarily contained within the intravascular space shortly after injection, provides information on blood flow to and distribution within the kidney. The MR signal change observed after administration of contrast agents varied dramatically depending upon the agents injected and the imaging parameters used. Hence a broad range of physiolgic processes may be described using these techniques, i.e. contrast agent enhanced functional MR examinations.

  14. Continuous-flow ultrasound assisted oxidative desulfurization (UAOD) process: An efficient diesel treatment by injection of the aqueous phase.

    PubMed

    Rahimi, Masoud; Shahhosseini, Shahrokh; Movahedirad, Salman

    2017-11-01

    A new continuous-flow ultrasound assisted oxidative desulfurization (UAOD) process was developed in order to decrease energy and aqueous phase consumption. In this process the aqueous phase is injected below the horn tip leading to enhanced mixing of the phases. Diesel fuel as the oil phase with sulfur content of 1550ppmw and an appropriate mixture of hydrogen peroxide and formic acid as the aqueous phase were used. At the first step, the optimized condition for the sulfur removal has been obtained in the batch mode operation. Hence, the effect of more important oxidation parameters; oxidant-to-sulfur molar ratio, acid-to-sulfur molar ratio and sonication time were investigated. Then the optimized conditions were obtained using Response Surface Methodology (RSM) technique. Afterwards, some experiments corresponding to the best batch condition and also with objective of minimizing the residence time and aqueous phase to fuel volume ratio have been conducted in a newly designed double-compartment reactor with injection of the aqueous phase to evaluate the process in a continuous flow operation. In addition, the effect of nozzle diameter has been examined. Significant improvement on the sulfur removal was observed specially in lower sonication time in the case of dispersion method in comparison with the conventional contact between two phases. Ultimately, the flow pattern induced by ultrasonic device, and also injection of the aqueous phase were analyzed quantitatively and qualitatively by capturing the sequential images. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. (Pea)nuts and Bolts of Visual Narrative: Structure and Meaning in Sequential Image Comprehension

    ERIC Educational Resources Information Center

    Cohn, Neil; Paczynski, Martin; Jackendoff, Ray; Holcomb, Phillip J.; Kuperberg, Gina R.

    2012-01-01

    Just as syntax differentiates coherent sentences from scrambled word strings, the comprehension of sequential images must also use a cognitive system to distinguish coherent narrative sequences from random strings of images. We conducted experiments analogous to two classic studies of language processing to examine the contributions of narrative…

  16. Field-Sequential Color Converter

    NASA Technical Reports Server (NTRS)

    Studer, Victor J.

    1989-01-01

    Electronic conversion circuit enables display of signals from field-sequential color-television camera on color video camera. Designed for incorporation into color-television monitor on Space Shuttle, circuit weighs less, takes up less space, and consumes less power than previous conversion equipment. Incorporates state-of-art memory devices, also used in terrestrial stationary or portable closed-circuit television systems.

  17. Apollo experience report: Command and service module sequential events control subsystem

    NASA Technical Reports Server (NTRS)

    Johnson, G. W.

    1975-01-01

    The Apollo command and service module sequential events control subsystem is described, with particular emphasis on the major systems and component problems and solutions. The subsystem requirements, design, and development and the test and flight history of the hardware are discussed. Recommendations to avoid similar problems on future programs are outlined.

  18. Sequential color video to parallel color video converter

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The engineering design, development, breadboard fabrication, test, and delivery of a breadboard field sequential color video to parallel color video converter is described. The converter was designed for use onboard a manned space vehicle to eliminate a flickering TV display picture and to reduce the weight and bulk of previous ground conversion systems.

  19. Considering User's Access Pattern in Multimedia File Systems

    NASA Astrophysics Data System (ADS)

    Cho, KyoungWoon; Ryu, YeonSeung; Won, Youjip; Koh, Kern

    2002-12-01

    Legacy buffer cache management schemes for multimedia server are grounded at the assumption that the application sequentially accesses the multimedia file. However, user access pattern may not be sequential in some circumstances, for example, in distance learning application, where the user may exploit the VCR-like function(rewind and play) of the system and accesses the particular segments of video repeatedly in the middle of sequential playback. Such a looping reference can cause a significant performance degradation of interval-based caching algorithms. And thus an appropriate buffer cache management scheme is required in order to deliver desirable performance even under the workload that exhibits looping reference behavior. We propose Adaptive Buffer cache Management(ABM) scheme which intelligently adapts to the file access characteristics. For each opened file, ABM applies either the LRU replacement or the interval-based caching depending on the Looping Reference Indicator, which indicates that how strong temporally localized access pattern is. According to our experiment, ABM exhibits better buffer cache miss ratio than interval-based caching or LRU, especially when the workload exhibits not only sequential but also looping reference property.

  20. Automated tagging of pharmaceutically active thiols under flow conditions using monobromobimane.

    PubMed

    Tzanavaras, Paraskevas D; Karakosta, Theano D

    2011-03-25

    The thiol-specific derivatization reagent monobromobimane (MBB) is applied--for the first time--under flow conditions. Sequential injection analysis allows the handling of precise volumes of the reagent in the micro-liter range. The effect of the main chemical and instrumental variables was investigated using captopril (CAP), N-acetylcysteine (NAC) and penicillamine (PEN) as representative pharmaceutically active thiols. Previously reported hydrolysis of MBB due to interaction with nucleophilic components of the buffers was avoided kinetically under flow conditions. The proposed analytical scheme is suitable for the fluorimetric determination of thiols at a sampling rate of 36 h(-1). Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Procedural and Physical Interventions for Vaccine Injections: Systematic Review of Randomized Controlled Trials and Quasi-Randomized Controlled Trials.

    PubMed

    Taddio, Anna; Shah, Vibhuti; McMurtry, C Meghan; MacDonald, Noni E; Ipp, Moshe; Riddell, Rebecca Pillai; Noel, Melanie; Chambers, Christine T

    2015-10-01

    This systematic review evaluated the effectiveness of physical and procedural interventions for reducing pain and related outcomes during vaccination. Databases were searched using a broad search strategy to identify relevant randomized and quasi-randomized controlled trials. Data were extracted according to procedure phase (preprocedure, acute, recovery, and combinations of these) and pooled using established methods. A total of 31 studies were included. Acute infant distress was diminished during intramuscular injection without aspiration (n=313): standardized mean difference (SMD) -0.82 (95% confidence interval [CI]: -1.18, -0.46). Injecting the most painful vaccine last during vaccinations reduced acute infant distress (n=196): SMD -0.69 (95% CI: -0.98, -0.4). Simultaneous injections reduced acute infant distress compared with sequential injections (n=172): SMD -0.56 (95% CI: -0.87, -0.25). There was no benefit of simultaneous injections in children. Less infant distress during the acute and recovery phases combined occurred with vastus lateralis (vs. deltoid) injections (n=185): SMD -0.70 (95% CI: -1.00, -0.41). Skin-to-skin contact in neonates (n=736) reduced acute distress: SMD -0.65 (95% CI: -1.05, -0.25). Holding infants reduced acute distress after removal of the data from 1 methodologically diverse study (n=107): SMD -1.25 (95% CI: -2.05, -0.46). Holding after vaccination (n=417) reduced infant distress during the acute and recovery phases combined: SMD -0.65 (95% CI: -1.08, -0.22). Self-reported fear was reduced for children positioned upright (n=107): SMD -0.39 (95% CI: -0.77, -0.01). Non-nutritive sucking (n=186) reduced acute distress in infants: SMD -1.88 (95% CI: -2.57, -1.18). Manual tactile stimulation did not reduce pain across the lifespan. An external vibrating device and cold reduced pain in children (n=145): SMD -1.23 (95% CI: -1.58, -0.87). There was no benefit of warming the vaccine in adults. Muscle tension was beneficial in selected indices of fainting in adolescents and adults. Interventions with evidence of benefit in select populations include: no aspiration, injecting most painful vaccine last, simultaneous injections, vastus lateralis injection, positioning interventions, non-nutritive sucking, external vibrating device with cold, and muscle tension.

  2. Fully vs. Sequentially Coupled Loads Analysis of Offshore Wind Turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Damiani, Rick; Wendt, Fabian; Musial, Walter

    The design and analysis methods for offshore wind turbines must consider the aerodynamic and hydrodynamic loads and response of the entire system (turbine, tower, substructure, and foundation) coupled to the turbine control system dynamics. Whereas a fully coupled (turbine and support structure) modeling approach is more rigorous, intellectual property concerns can preclude this approach. In fact, turbine control system algorithms and turbine properties are strictly guarded and often not shared. In many cases, a partially coupled analysis using separate tools and an exchange of reduced sets of data via sequential coupling may be necessary. In the sequentially coupled approach, themore » turbine and substructure designers will independently determine and exchange an abridged model of their respective subsystems to be used in their partners' dynamic simulations. Although the ability to achieve design optimization is sacrificed to some degree with a sequentially coupled analysis method, the central question here is whether this approach can deliver the required safety and how the differences in the results from the fully coupled method could affect the design. This work summarizes the scope and preliminary results of a study conducted for the Bureau of Safety and Environmental Enforcement aimed at quantifying differences between these approaches through aero-hydro-servo-elastic simulations of two offshore wind turbines on a monopile and jacket substructure.« less

  3. Automated Discovery and Modeling of Sequential Patterns Preceding Events of Interest

    NASA Technical Reports Server (NTRS)

    Rohloff, Kurt

    2010-01-01

    The integration of emerging data manipulation technologies has enabled a paradigm shift in practitioners' abilities to understand and anticipate events of interest in complex systems. Example events of interest include outbreaks of socio-political violence in nation-states. Rather than relying on human-centric modeling efforts that are limited by the availability of SMEs, automated data processing technologies has enabled the development of innovative automated complex system modeling and predictive analysis technologies. We introduce one such emerging modeling technology - the sequential pattern methodology. We have applied the sequential pattern methodology to automatically identify patterns of observed behavior that precede outbreaks of socio-political violence such as riots, rebellions and coups in nation-states. The sequential pattern methodology is a groundbreaking approach to automated complex system model discovery because it generates easily interpretable patterns based on direct observations of sampled factor data for a deeper understanding of societal behaviors that is tolerant of observation noise and missing data. The discovered patterns are simple to interpret and mimic human's identifications of observed trends in temporal data. Discovered patterns also provide an automated forecasting ability: we discuss an example of using discovered patterns coupled with a rich data environment to forecast various types of socio-political violence in nation-states.

  4. Comparison of solution-mixed and sequentially processed P3HT: F4TCNQ films: effect of doping-induced aggregation on film morphology

    DOE PAGES

    Jacobs, Ian E.; Aasen, Erik W.; Oliveira, Julia L.; ...

    2016-03-23

    Doping polymeric semiconductors often drastically reduces the solubility of the polymer, leading to difficulties in processing doped films. Here, we compare optical, electrical, and morphological properties of P3HT films doped with F4TCNQ, both from mixed solutions and using sequential solution processing with orthogonal solvents. We demonstrate that sequential doping occurs rapidly (<1 s), and that the film doping level can be precisely controlled by varying the concentration of the doping solution. Furthermore, the choice of sequential doping solvent controls whether dopant anions are included or excluded from polymer crystallites. Atomic force microscopy (AFM) reveals that sequential doping produces significantly moremore » uniform films on the nanoscale than the mixed-solution method. In addition, we show that mixed-solution doping induces the formation of aggregates even at low doping levels, resulting in drastic changes to film morphology. Sequentially coated films show 3–15 times higher conductivities at a given doping level than solution-doped films, with sequentially doped films processed to exclude dopant anions from polymer crystallites showing the highest conductivities. In conclusion, we propose a mechanism for doping induced aggregation in which the shift of the polymer HOMO level upon aggregation couples ionization and solvation energies. To show that the methodology is widely applicable, we demonstrate that several different polymer:dopant systems can be prepared by sequential doping.« less

  5. Comparison of solution-mixed and sequentially processed P3HT: F4TCNQ films: effect of doping-induced aggregation on film morphology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, Ian E.; Aasen, Erik W.; Oliveira, Julia L.

    Doping polymeric semiconductors often drastically reduces the solubility of the polymer, leading to difficulties in processing doped films. Here, we compare optical, electrical, and morphological properties of P3HT films doped with F4TCNQ, both from mixed solutions and using sequential solution processing with orthogonal solvents. We demonstrate that sequential doping occurs rapidly (<1 s), and that the film doping level can be precisely controlled by varying the concentration of the doping solution. Furthermore, the choice of sequential doping solvent controls whether dopant anions are included or excluded from polymer crystallites. Atomic force microscopy (AFM) reveals that sequential doping produces significantly moremore » uniform films on the nanoscale than the mixed-solution method. In addition, we show that mixed-solution doping induces the formation of aggregates even at low doping levels, resulting in drastic changes to film morphology. Sequentially coated films show 3–15 times higher conductivities at a given doping level than solution-doped films, with sequentially doped films processed to exclude dopant anions from polymer crystallites showing the highest conductivities. In conclusion, we propose a mechanism for doping induced aggregation in which the shift of the polymer HOMO level upon aggregation couples ionization and solvation energies. To show that the methodology is widely applicable, we demonstrate that several different polymer:dopant systems can be prepared by sequential doping.« less

  6. Generalized bipartite quantum state discrimination problems with sequential measurements

    NASA Astrophysics Data System (ADS)

    Nakahira, Kenji; Kato, Kentaro; Usuda, Tsuyoshi Sasaki

    2018-02-01

    We investigate an optimization problem of finding quantum sequential measurements, which forms a wide class of state discrimination problems with the restriction that only local operations and one-way classical communication are allowed. Sequential measurements from Alice to Bob on a bipartite system are considered. Using the fact that the optimization problem can be formulated as a problem with only Alice's measurement and is convex programming, we derive its dual problem and necessary and sufficient conditions for an optimal solution. Our results are applicable to various practical optimization criteria, including the Bayes criterion, the Neyman-Pearson criterion, and the minimax criterion. In the setting of the problem of finding an optimal global measurement, its dual problem and necessary and sufficient conditions for an optimal solution have been widely used to obtain analytical and numerical expressions for optimal solutions. Similarly, our results are useful to obtain analytical and numerical expressions for optimal sequential measurements. Examples in which our results can be used to obtain an analytical expression for an optimal sequential measurement are provided.

  7. Cortical responses following simultaneous and sequential retinal neurostimulation with different return configurations.

    PubMed

    Barriga-Rivera, Alejandro; Morley, John W; Lovell, Nigel H; Suaning, Gregg J

    2016-08-01

    Researchers continue to develop visual prostheses towards safer and more efficacious systems. However limitations still exist in the number of stimulating channels that can be integrated. Therefore there is a need for spatial and time multiplexing techniques to provide improved performance of the current technology. In particular, bright and high-contrast visual scenes may require simultaneous activation of several electrodes. In this research, a 24-electrode array was suprachoroidally implanted in three normally-sighted cats. Multi-unit activity was recorded from the primary visual cortex. Four stimulation strategies were contrasted to provide activation of seven electrodes arranged hexagonally: simultaneous monopolar, sequential monopolar, sequential bipolar and hexapolar. Both monopolar configurations showed similar cortical activation maps. Hexapolar and sequential bipolar configurations activated a lower number of cortical channels. Overall, the return configuration played a more relevant role in cortical activation than time multiplexing and thus, rapid sequential stimulation may assist in reducing the number of channels required to activate large retinal areas.

  8. Anatomic Site Variability in Rat Skeletal Uptake and Desorption Of Fluorescently Labeled Bisphosphonate

    PubMed Central

    Wen, D.; Qing, L.; Harrison, G.; Golub, E.; Akintoye, S.O.

    2010-01-01

    Objectives Bisphosphonates commonly used to treat osteoporosis, Paget’s disease, multiple myeloma, hypercalcemia of malignancy and osteolytic lesions of cancer metastasis have been associated with bisphosphonate-associated jaw osteonecrosis (BJON). The underlying pathogenesis of BJON is unclear, but disproportionate bisphosphonate concentration in the jaw has been proposed as one potential etiological factor. This study tested the hypothesis that skeletal biodistribution of intravenous bisphosphonate is anatomic site-dependent in a rat model system. Materials and Methods Fluorescently labeled pamidronate was injected intravenously in athymic rats of equal weights followed by in vivo whole body fluorimetry, ex vivo optical imaging of oral, axial and appendicular bones and ethylenediaminetetraacetic acid bone decalcification to assess hydroxyapatite-bound bisphosphonate. Results Bisphosphonate uptake and bisphosphonate released per unit calcium were similar in oral and appendicular bones but lower than those in axial bones. Hydroxyapatite-bound bisphosphonate liberated by sequential acid decalcification was highest in oral relative to axial and appendicular bones (p < 0.05). Conclusions This study demonstrates regional differences in uptake and release of bisphosphonate from oral, axial and appendicular bones of immune deficient rats. PMID:21122034

  9. Abundance and modes of occurrence of mercury in some low-sulfur coals from China

    USGS Publications Warehouse

    Zheng, Lingyun; Liu, Gaisheng; Chou, C.-L.

    2008-01-01

    Mercury (Hg) is one of the hazardous trace elements in coal. Mercury in coal is almost totally emitted into the atmosphere during coal combustion. Especially for utilities burning low-sulfur coals that do not require scrubbers, Hg reduction will be neglected. Hg abundances of 52 low-sulfur coal samples from different coalfields in six provinces of China were determined by a flow injection mercury system (FIMS). The results show that Hg abundances in selected low-sulfur coals range from 0.03??ppm to 0.79??ppm, with an arithmetic mean of 0.24??ppm, which is higher than that of average Chinese coals (0.19??ppm). Correlation analysis and sequential extraction procedures are performed to study possible modes of occurrence of Hg in low-sulfur coals. Modes of occurrence of Hg are variable in low-sulfur coals, and the sulfide-bound and organic-bound Hg may be the dominant forms. In addition, the silicate-bound Hg may be the main form in some of these coals because of magmatic intrusion. ?? 2007 Elsevier B.V. All rights reserved.

  10. In-situ monitoring of H2O2 degradation by live cells using voltammetric detection in a lab-on-valve system.

    PubMed

    Lähdesmäki, Ilkka; Park, Young K; Carroll, Andrea D; Decuir, Michael; Ruzicka, Jaromir

    2007-08-01

    This paper describes a method for monitoring the degradation of hydrogen peroxide by cells immobilized on a beaded support. The detection is based on the voltammetric reduction of hydrogen peroxide on a mercury film working electrode, whilst combining the concept of sequential injection (SI) with the lab-on-valve (LOV) manifold allows the measurements to be carried out in real time and automatically, in well-defined conditions. The method is shown to be capable of simultaneously monitoring hydrogen peroxide in the 10-1000 microM range and oxygen in the 160-616 microM range. A correction algorithm has been used to ensure reliable H2O2 results in the presence of varying oxygen levels. The method has been successfully applied to monitoring the degradation of H2O2 by wild-type cells and by catalase-overexpressing mouse embryonic fibroblasts. Since the technique allows the monitoring of the initial response rate, it provides data not accessible by current methods that are end-point-based measurements.

  11. A mid-infrared flow-through sensor for label-free monitoring of enzyme inhibition.

    PubMed

    Armenta, S; Tomischko, W; Lendl, B

    2008-12-01

    Label-free monitoring of acetylcholinesterase (AChE) activity was achieved with a mid-infrared flow-through sensor. The flow-through sensor comprised agarose beads, carrying covalently immobilized AChE, which were placed in a temperature-controlled (37 degrees C) CaF(2) flow cell with an optical path of 60 mum. The sensor was incorporated into a computer-controlled sequential injection (SI) system for automated liquid handling. Different mixtures of enzyme substrate acetylcholine (ACh) and inhibitor (tacrine) were prepared and fed into the flow-through sensor. The flow was stopped as soon as the prepared mixtures reached the sensor. Enzymatic hydrolysis of ACh by AChE was directly monitored as it took place in the flow-through sensor. The inhibition effect of tacrine was calculated from the reaction-induced spectral changes, revealing an important decrease in the activity of AChE, approaching zero when the inhibitor concentration is high enough. The developed mid-infrared flow-through sensor is flexible and can be used to study the inhibitor activity of different target molecules as well as different enzymes.

  12. A SEQUENTIAL, MULTIPLE-TREATMENT, TARGETED APPROACH TO REDUCE WOUND HEALING AND FAILURE OF GLAUCOMA FILTRATION SURGERY IN A RABBIT MODEL (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    PubMed Central

    Sherwood, Mark Brian

    2006-01-01

    Purpose The purpose of this study was to evaluate the concept of targeting mediators of the scarring process at multiple points across the course of bleb failure, in order to prolong bleb survival. Methods There were three linked parts to the experiment. In the first part, a cannula glaucoma filtration surgery (GFS) was performed on 32 New Zealand White (NZW) rabbits, and bleb survival was assessed for six different regimens plus controls by grading bleb height and width. For the second part of the study, the same GFS surgery was performed on an additional 10 NZW rabbits. Two additional filtering blebs were treated with balanced saline solution (BSS), two received mitomycin-C (MMC) (0.4 mg/mL), and for the remaining six, a sequential regimen was given consisting of 200 mmol/L mannose-6-phosphate (M-6-P) solution at the time of surgery, followed by subconjunctival injections of antibody to connective tissue growth factor at days 2 and 4, and Ilomastat, a broad-spectrum matrix metalloproteinase inhibitor, at days 7, 12, and 20 postoperatively. Bleb survival was again assessed. In the final part of the experiment, blebs treated with either BSS, MMC, or the above sequential multitreatment regimen were examined histologically at 14 days postoperatively in three additional NZW rabbits. Results All six individual therapies selected resulted in some improvement of bleb survival compared to BSS control. Blebs treated with the new sequential, multitreatment protocol survived an average of 29 days (regression slope, P < .0001 compared to control), those receiving BSS an average of 17 days, and those treated with MMC (0.4 mg/mL) an average of 36 days. The sequential, multitreatment regimen was significantly superior to any of the six monotherapies for time to zero analysis (flattening) of the bleb (P < .002). Histologic examination of the bleb tissues showed a markedly less epithelial thinning, subepithelial collagen thinning, and goblet cell loss in the multitreatment group, when compared with the MMC blebs. Conclusions In a rabbit model of GFS, a sequential, targeted, multitreatment approach prolonged bleb survival compared to BSS controls and decreased bleb tissue morphological changes when compared to those treated with MMC. It is not known whether these findings can be reproduced in humans, and further work is needed to determine an optimum regimen and timing of therapeutic delivery. PMID:17471357

  13. Exosomes from embryonic mesenchymal stem cells alleviate osteoarthritis through balancing synthesis and degradation of cartilage extracellular matrix.

    PubMed

    Wang, Yafei; Yu, Dongsheng; Liu, Zhiming; Zhou, Fang; Dai, Jun; Wu, Bingbing; Zhou, Jing; Heng, Boon Chin; Zou, Xiao Hui; Ouyang, Hongwei; Liu, Hua

    2017-08-14

    Mesenchymal stem cell therapy for osteoarthritis (OA) has been widely investigated, but the mechanisms are still unclear. Exosomes that serve as carriers of genetic information have been implicated in many diseases and are known to participate in many physiological processes. Here, we investigate the therapeutic potential of exosomes from human embryonic stem cell-induced mesenchymal stem cells (ESC-MSCs) in alleviating osteoarthritis (OA). Exosomes were harvested from conditioned culture media of ESC-MSCs by a sequential centrifugation process. Primary mouse chondrocytes treated with interleukin 1 beta (IL-1β) were used as an in vitro model to evaluate the effects of the conditioned medium with or without exosomes and titrated doses of isolated exosomes for 48 hours, prior to immunocytochemistry or western blot analysis. Destabilization of the medial meniscus (DMM) surgery was performed on the knee joints of C57BL/6 J mice as an OA model. This was followed by intra-articular injection of either ESC-MSCs or their exosomes. Cartilage destruction and matrix degradation were evaluated with histological staining and OARSI scores at the post-surgery 8 weeks. We found that intra-articular injection of ESC-MSCs alleviated cartilage destruction and matrix degradation in the DMM model. Further in vitro studies illustrated that this effect was exerted through ESC-MSC-derived exosomes. These exosomes maintained the chondrocyte phenotype by increasing collagen type II synthesis and decreasing ADAMTS5 expression in the presence of IL-1β. Immunocytochemistry revealed colocalization of the exosomes and collagen type II-positive chondrocytes. Subsequent intra-articular injection of exosomes derived from ESC-MSCs successfully impeded cartilage destruction in the DMM model. The exosomes from ESC-MSCs exert a beneficial therapeutic effect on OA by balancing the synthesis and degradation of chondrocyte extracellular matrix (ECM), which in turn provides a new target for OA drug and drug-delivery system development.

  14. First-Episode Psychosis and the Criminal Justice System: Using a Sequential Intercept Framework to Highlight Risks and Opportunities.

    PubMed

    Wasser, Tobias; Pollard, Jessica; Fisk, Deborah; Srihari, Vinod

    2017-10-01

    In first-episode psychosis there is a heightened risk of aggression and subsequent criminal justice involvement. This column reviews the evidence pointing to these heightened risks and highlights opportunities, using a sequential intercept model, for collaboration between mental health services and existing diversionary programs, particularly for patients whose behavior has already brought them to the attention of the criminal justice system. Coordinating efforts in these areas across criminal justice and clinical spheres can decrease the caseload burden on the criminal justice system and optimize clinical and legal outcomes for this population.

  15. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  16. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  17. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  18. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  19. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  20. Assessment of sequential same arm agreement of blood pressure measurements by a CVProfilor DO-2020 versus a Baumanometer mercury sphygmomanometer.

    PubMed

    Prisant, L M; Resnick, L M; Hollenberg, S M

    2001-06-01

    The aim of this study was to assess the accuracy of sequential same arm blood pressure measurement by the mercury sphygmomanometer with the oscillometric blood pressure measurements from a device that also determines arterial elasticity. A prospective, multicentre, clinical study evaluated sequential same arm blood pressure measurements, using a mercury sphygmomanometer (Baumanometer, W. A. Baum Co., Inc., Copiague, New York, USA) and an oscillometric non-invasive device that calculates arterial elasticity (CVProfilor DO-2020 Cardiovascular Profiling System, Hypertension Diagnostics, Inc., Eagan, Minnesota, USA). Blood pressure was measured supine in triplicate, 3 min apart in a randomized sequence after a period of rest. The study population of 230 normotensive and hypertensive subjects included 57% females, 51% Caucasians, and 33% African Americans. The mean difference between test methods of systolic blood pressure, diastolic blood pressure, and heart rate was -3.2 +/- 6.9 mmHg, +0.8 +/- 5.9 mmHg, and +1.0 +/- 5.7 beats/minute. For systolic and diastolic blood pressure, 60.9 and 70.4% of sequential measurements by each method were within +/- 5 mmHg. Few or no points fell beyond the mean +/- 2 standard deviations lines for each cuff bladder size. Sequential same arm measurements of the CVProfilor DO-2020 Cardiovascular Profiling System measures blood pressure by an oscillometric method (dynamic linear deflation) with reasonable agreement with a mercury sphygmomanometer.

  1. Modeling eye gaze patterns in clinician-patient interaction with lag sequential analysis.

    PubMed

    Montague, Enid; Xu, Jie; Chen, Ping-Yu; Asan, Onur; Barrett, Bruce P; Chewning, Betty

    2011-10-01

    The aim of this study was to examine whether lag sequential analysis could be used to describe eye gaze orientation between clinicians and patients in the medical encounter. This topic is particularly important as new technologies are implemented into multiuser health care settings in which trust is critical and nonverbal cues are integral to achieving trust. This analysis method could lead to design guidelines for technologies and more effective assessments of interventions. Nonverbal communication patterns are important aspects of clinician-patient interactions and may affect patient outcomes. The eye gaze behaviors of clinicians and patients in 110 videotaped medical encounters were analyzed using the lag sequential method to identify significant behavior sequences. Lag sequential analysis included both event-based lag and time-based lag. Results from event-based lag analysis showed that the patient's gaze followed that of the clinician, whereas the clinician's gaze did not follow the patient's. Time-based sequential analysis showed that responses from the patient usually occurred within 2 s after the initial behavior of the clinician. Our data suggest that the clinician's gaze significantly affects the medical encounter but that the converse is not true. Findings from this research have implications for the design of clinical work systems and modeling interactions. Similar research methods could be used to identify different behavior patterns in clinical settings (physical layout, technology, etc.) to facilitate and evaluate clinical work system designs.

  2. Modeling Eye Gaze Patterns in Clinician-Patient Interaction with Lag Sequential Analysis

    PubMed Central

    Montague, E; Xu, J; Asan, O; Chen, P; Chewning, B; Barrett, B

    2011-01-01

    Objective The aim of this study was to examine whether lag-sequential analysis could be used to describe eye gaze orientation between clinicians and patients in the medical encounter. This topic is particularly important as new technologies are implemented into multi-user health care settings where trust is critical and nonverbal cues are integral to achieving trust. This analysis method could lead to design guidelines for technologies and more effective assessments of interventions. Background Nonverbal communication patterns are important aspects of clinician-patient interactions and may impact patient outcomes. Method Eye gaze behaviors of clinicians and patients in 110-videotaped medical encounters were analyzed using the lag-sequential method to identify significant behavior sequences. Lag-sequential analysis included both event-based lag and time-based lag. Results Results from event-based lag analysis showed that the patients’ gaze followed that of clinicians, while clinicians did not follow patients. Time-based sequential analysis showed that responses from the patient usually occurred within two seconds after the initial behavior of the clinician. Conclusion Our data suggest that the clinician’s gaze significantly affects the medical encounter but not the converse. Application Findings from this research have implications for the design of clinical work systems and modeling interactions. Similar research methods could be used to identify different behavior patterns in clinical settings (physical layout, technology, etc.) to facilitate and evaluate clinical work system designs. PMID:22046723

  3. Bursts and heavy tails in temporal and sequential dynamics of foraging decisions.

    PubMed

    Jung, Kanghoon; Jang, Hyeran; Kralik, Jerald D; Jeong, Jaeseung

    2014-08-01

    A fundamental understanding of behavior requires predicting when and what an individual will choose. However, the actual temporal and sequential dynamics of successive choices made among multiple alternatives remain unclear. In the current study, we tested the hypothesis that there is a general bursting property in both the timing and sequential patterns of foraging decisions. We conducted a foraging experiment in which rats chose among four different foods over a continuous two-week time period. Regarding when choices were made, we found bursts of rapidly occurring actions, separated by time-varying inactive periods, partially based on a circadian rhythm. Regarding what was chosen, we found sequential dynamics in affective choices characterized by two key features: (a) a highly biased choice distribution; and (b) preferential attachment, in which the animals were more likely to choose what they had previously chosen. To capture the temporal dynamics, we propose a dual-state model consisting of active and inactive states. We also introduce a satiation-attainment process for bursty activity, and a non-homogeneous Poisson process for longer inactivity between bursts. For the sequential dynamics, we propose a dual-control model consisting of goal-directed and habit systems, based on outcome valuation and choice history, respectively. This study provides insights into how the bursty nature of behavior emerges from the interaction of different underlying systems, leading to heavy tails in the distribution of behavior over time and choices.

  4. Development of high-accuracy convection schemes for sequential solvers

    NASA Technical Reports Server (NTRS)

    Thakur, Siddharth; Shyy, Wei

    1993-01-01

    An exploration is conducted of the applicability of such high resolution schemes as TVD to the resolving of sharp flow gradients using a sequential solution approach borrowed from pressure-based algorithms. It is shown that by extending these high-resolution shock-capturing schemes to a sequential solver that treats the equations as a collection of scalar conservation equations, the speed of signal propagation in the solution has to be coordinated by assigning the local convection speed as the characteristic speed for the entire system. A higher amount of dissipation is therefore needed to eliminate oscillations near discontinuities.

  5. The Effects of Partial Reinforcement in the Acquisition and Extinction of Recurrent Serial Patterns.

    ERIC Educational Resources Information Center

    Dockstader, Steven L.

    The purpose of these 2 experiments was to determine whether sequential response pattern behavior is affected by partial reinforcement in the same way as other behavior systems. The first experiment investigated the partial reinforcement extinction effects (PREE) in a sequential concept learning task where subjects were required to learn a…

  6. Automation at the Fairfax County Virginia Library System.

    ERIC Educational Resources Information Center

    Baker, Alfred W.; And Others

    The Fairfax County Library converted from a card catalog to a book catalog format in 1963. The first book catalogs were produced by the Sequential Card (SC) process. The master cards were prepared by the library and sent to Science Press, where copy was prepared on IBM cards, coded for sequential filing, and photographed to prepare page plates,…

  7. A Complementary Note to 'A Lag-1 Smoother Approach to System-Error Estimation': The Intrinsic Limitations of Residual Diagnostics

    NASA Technical Reports Server (NTRS)

    Todling, Ricardo

    2015-01-01

    Recently, this author studied an approach to the estimation of system error based on combining observation residuals derived from a sequential filter and fixed lag-1 smoother. While extending the methodology to a variational formulation, experimenting with simple models and making sure consistency was found between the sequential and variational formulations, the limitations of the residual-based approach came clearly to the surface. This note uses the sequential assimilation application to simple nonlinear dynamics to highlight the issue. Only when some of the underlying error statistics are assumed known is it possible to estimate the unknown component. In general, when considerable uncertainties exist in the underlying statistics as a whole, attempts to obtain separate estimates of the various error covariances are bound to lead to misrepresentation of errors. The conclusions are particularly relevant to present-day attempts to estimate observation-error correlations from observation residual statistics. A brief illustration of the issue is also provided by comparing estimates of error correlations derived from a quasi-operational assimilation system and a corresponding Observing System Simulation Experiments framework.

  8. Efficient Mining and Detection of Sequential Intrusion Patterns for Network Intrusion Detection Systems

    NASA Astrophysics Data System (ADS)

    Shyu, Mei-Ling; Huang, Zifang; Luo, Hongli

    In recent years, pervasive computing infrastructures have greatly improved the interaction between human and system. As we put more reliance on these computing infrastructures, we also face threats of network intrusion and/or any new forms of undesirable IT-based activities. Hence, network security has become an extremely important issue, which is closely connected with homeland security, business transactions, and people's daily life. Accurate and efficient intrusion detection technologies are required to safeguard the network systems and the critical information transmitted in the network systems. In this chapter, a novel network intrusion detection framework for mining and detecting sequential intrusion patterns is proposed. The proposed framework consists of a Collateral Representative Subspace Projection Modeling (C-RSPM) component for supervised classification, and an inter-transactional association rule mining method based on Layer Divided Modeling (LDM) for temporal pattern analysis. Experiments on the KDD99 data set and the traffic data set generated by a private LAN testbed show promising results with high detection rates, low processing time, and low false alarm rates in mining and detecting sequential intrusion detections.

  9. Speckle pattern sequential extraction metric for estimating the focus spot size on a remote diffuse target.

    PubMed

    Yu, Zhan; Li, Yuanyang; Liu, Lisheng; Guo, Jin; Wang, Tingfeng; Yang, Guoqing

    2017-11-10

    The speckle pattern (line by line) sequential extraction (SPSE) metric is proposed by the one-dimensional speckle intensity level crossing theory. Through the sequential extraction of received speckle information, the speckle metrics for estimating the variation of focusing spot size on a remote diffuse target are obtained. Based on the simulation, we will give some discussions about the SPSE metric range of application under the theoretical conditions, and the aperture size will affect the metric performance of the observation system. The results of the analyses are verified by the experiment. This method is applied to the detection of relative static target (speckled jitter frequency is less than the CCD sampling frequency). The SPSE metric can determine the variation of the focusing spot size over a long distance, moreover, the metric will estimate the spot size under some conditions. Therefore, the monitoring and the feedback of far-field spot will be implemented laser focusing system applications and help the system to optimize the focusing performance.

  10. An Innovative Needle-free Injection System: Comparison to 1 ml Standard Subcutaneous Injection.

    PubMed

    Kojic, Nikola; Goyal, Pragun; Lou, Cheryl Hamer; Corwin, Michael J

    2017-11-01

    A needle-free delivery system may lead to improved satisfaction and compliance, as well as reduced anxiety among patients requiring frequent or ongoing injections. This report describes a first-in-man assessment comparing Portal Instruments' innovative needle-free injection system with subcutaneous injections using a 27G needle. Forty healthy volunteer participants each received a total of four injections of 1.0 mL sterile saline solution, two with a standard subcutaneous injection using a 27G needle, and two using the Portal injection system. Perception of pain was measured using a 100-mm visual analog scale (VAS). Injection site reactions were assessed at 2 min and at 20-30 min after each injection. Follow-up contact was made 24-48 h after the injections. Subject preference regarding injection type was also assessed. VAS pain scores at Portal injection sites met the criteria to be considered non-inferior to the pain reported at 27G needle injection sites (i.e., upper 95% confidence bound less than +5 mm). Based on a mixed effects model, at time 0, accounting for potential confounding variables, the adjusted difference in VAS scores indicated that Portal injections were 6.5 mm lower than the 27G needle injections (95% CI -10.5, -2.5). No clinically important adverse events were noted. Portal injections were preferred by 24 (60%) of the subjects (P = 0.0015). As an early step in the development of this new needle-free delivery system, the current study has shown that a 1.0-mL saline injection can be given with less pain reported than a standard subcutaneous injection using a 27G needle.

  11. Evidence for decreased interaction and improved carotenoid bioavailability by sequential delivery of a supplement.

    PubMed

    Salter-Venzon, Dawna; Kazlova, Valentina; Izzy Ford, Samantha; Intra, Janjira; Klosner, Allison E; Gellenbeck, Kevin W

    2017-05-01

    Despite the notable health benefits of carotenoids for human health, the majority of human diets worldwide are repeatedly shown to be inadequate in intake of carotenoid-rich fruits and vegetables, according to current health recommendations. To address this deficit, strategies designed to increase dietary intakes and subsequent plasma levels of carotenoids are warranted. When mixed carotenoids are delivered into the intestinal tract simultaneously, competition occurs for micelle formation and absorption, affecting carotenoid bioavailability. Previously, we tested the in vitro viability of a carotenoid mix designed to deliver individual carotenoids sequentially spaced from one another over the 6 hr transit time of the human upper gastrointestinal system. We hypothesized that temporally and spatially separating the individual carotenoids would reduce competition for micelle formation, improve uptake, and maximize efficacy. Here, we test this hypothesis in a double-blind, repeated-measure, cross-over human study with 12 subjects by comparing the change of plasma carotenoid levels for 8 hr after oral doses of a sequentially spaced carotenoid mix, to a matched mix without sequential spacing. We find the carotenoid change from baseline, measured as area under the curve, is increased following consumption of the sequentially spaced mix compared to concomitant carotenoids delivery. These results demonstrate reduced interaction and regulation between the sequentially spaced carotenoids, suggesting improved bioavailability from a novel sequentially spaced carotenoid mix.

  12. Improving the Energy Market: Algorithms, Market Implications, and Transmission Switching

    NASA Astrophysics Data System (ADS)

    Lipka, Paula Ann

    This dissertation aims to improve ISO operations through a better real-time market solution algorithm that directly considers both real and reactive power, finds a feasible Alternating Current Optimal Power Flow solution, and allows for solving transmission switching problems in an AC setting. Most of the IEEE systems do not contain any thermal limits on lines, and the ones that do are often not binding. Chapter 3 modifies the thermal limits for the IEEE systems to create new, interesting test cases. Algorithms created to better solve the power flow problem often solve the IEEE cases without line limits. However, one of the factors that makes the power flow problem hard is thermal limits on the lines. The transmission networks in practice often have transmission lines that become congested, and it is unrealistic to ignore line limits. Modifying the IEEE test cases makes it possible for other researchers to be able to test their algorithms on a setup that is closer to the actual ISO setup. This thesis also examines how to convert limits given on apparent power---as is in the case in the Polish test systems---to limits on current. The main consideration in setting line limits is temperature, which linearly relates to current. Setting limits on real or apparent power is actually a proxy for using the limits on current. Therefore, Chapter 3 shows how to convert back to the best physical representation of line limits. A sequential linearization of the current-voltage formulation of the Alternating Current Optimal Power Flow (ACOPF) problem is used to find an AC-feasible generator dispatch. In this sequential linearization, there are parameters that are set to the previous optimal solution. Additionally, to improve accuracy of the Taylor series approximations that are used, the movement of the voltage is restricted. The movement of the voltage is allowed to be very large at the first iteration and is restricted further on each subsequent iteration, with the restriction corresponding to the accuracy and AC-feasiblity of the solution. This linearization was tested on the IEEE and Polish systems, which range from 14 to 3375 buses and 20 to 4161 transmission lines. It had an accuracy of 0.5% or less for all but the 30-bus system. It also solved in linear time with CPLEX, while the non-linear version solved in O(n1.11) to O(n1.39). The sequential linearization is slower than the nonlinear formulation for smaller problems, but faster for larger problems, and its linear computational time means it would continue solving faster for larger problems. A major consideration to implementing algorithms to solve the optimal generator dispatch is ensuring that the resulting prices from the algorithm will support the market. Since the sequential linearization is linear, it is convex, its marginal values are well-defined, and there is no duality gap. The prices and settlements obtained from the sequential linearization therefore can be used to run a market. This market will include extra prices and settlements for reactive power and voltage, compared to the present-day market, which is based on real power. An advantage of this is that there is a very clear pool that can be used for reactive power/voltage support payments, while presently there is not a clear pool to take them out of. This method also reveals how valuable reactive power and voltage are at different locations, which can enable better planning of reactive resource construction. Transmission switching increases the feasible region of the generator dispatch, which means there may be a better solution than without transmission switching. Power flows on transmission lines are not directly controllable; rather, the power flows according to how it is injected and the physical characteristics of the lines. Changing the network topology changes the physical characteristics, which changes the flows. This means that sets of generator dispatch that may have previously been infeasible due to the flow exceeding line constraints may be feasible, since the flows will be different and may meet line constraints. However, transmission switching is a mixed integer problem, which may have a very slow solution time. For economic switching, we examine a series of heuristics. We examine the congestion rent heuristic in detail and then examine many other heuristics at a higher level. Post-contingency corrective switching aims to fix issues in the power network after a line or generator outage. In Chapter 7, we show that using the sequential linear program with corrective switching helps solve voltage and excessive flow issues. (Abstract shortened by UMI.).

  13. Single-Cell Resolution Imaging of Retinal Ganglion Cell Apoptosis In Vivo Using a Cell-Penetrating Caspase-Activatable Peptide Probe

    PubMed Central

    Qiu, Xudong; Johnson, James R.; Wilson, Bradley S.; Gammon, Seth T.; Piwnica-Worms, David; Barnett, Edward M.

    2014-01-01

    Peptide probes for imaging retinal ganglion cell (RGC) apoptosis consist of a cell-penetrating peptide targeting moiety and a fluorophore-quencher pair flanking an effector caspase consensus sequence. Using ex vivo fluorescence imaging, we previously validated the capacity of these probes to identify apoptotic RGCs in cell culture and in an in vivo rat model of N-methyl- D-aspartate (NMDA)-induced neurotoxicity. Herein, using TcapQ488, a new probe designed and synthesized for compatibility with clinically-relevant imaging instruments, and real time imaging of a live rat RGC degeneration model, we fully characterized time- and dose-dependent probe activation, signal-to-noise ratios, and probe safety profiles in vivo. Adult rats received intravitreal injections of four NMDA concentrations followed by varying TcapQ488 doses. Fluorescence fundus imaging was performed sequentially in vivo using a confocal scanning laser ophthalmoscope and individual RGCs displaying activated probe were counted and analyzed. Rats also underwent electroretinography following intravitreal injection of probe. In vivo fluorescence fundus imaging revealed distinct single-cell probe activation as an indicator of RGC apoptosis induced by intravitreal NMDA injection that corresponded to the identical cells observed in retinal flat mounts of the same eye. Peak activation of probe in vivo was detected 12 hours post probe injection. Detectable fluorescent RGCs increased with increasing NMDA concentration; sensitivity of detection generally increased with increasing TcapQ488 dose until saturating at 0.387 nmol. Electroretinography following intravitreal injections of TcapQ488 showed no significant difference compared with control injections. We optimized the signal-to-noise ratio of a caspase-activatable cell penetrating peptide probe for quantitative non-invasive detection of RGC apoptosis in vivo. Full characterization of probe performance in this setting creates an important in vivo imaging standard for functional evaluation of future probe analogues and provides a basis for extending this strategy into glaucoma-specific animal models. PMID:24586415

  14. Light-controlled drug release from singlet-oxygen sensitive nanoscale coordination polymers enabling cancer combination therapy.

    PubMed

    Liu, Jingjing; Yang, Guangbao; Zhu, Wenwen; Dong, Ziliang; Yang, Yu; Chao, Yu; Liu, Zhuang

    2017-11-01

    The development of smart drug delivery systems to realize controlled drug release for highly specific cancer treatment has attracted tremendous attention. Herein, nanoscale coordination polymers (NCPs) constructed from hafnium ions and bis-(alkylthio) alkene (BATA), a singlet-oxygen responsive linker, are fabricated and applied as nanocarriers to realize light-controlled drug release under a rather low optical power density. In this system, NCPs synthesized through a solvothermal method are sequentially loaded with chlorin e6 (Ce6), a photosensitizer, and doxorubicin (DOX), a chemotherapeutic drug, and then coated with lipid bilayer to allow modification with polyethylene glycol (PEG) to acquire excellent colloidal stability. The singlet oxygen produced by such NCP-Ce6-DOX-PEG nanocomposite can be used not only for photodynamic therapy, but also to induce the break of BATA linker and thus the destruction of nanoparticle structures under light exposure, thereby triggering effective drug release. Notably, with efficient tumor accumulation after intravenous injection as revealed by CT imaging, those NCP-Ce6-DOX-PEG nanoparticles could be utilized for combined chemo-photodynamic therapy with great antitumor efficacy. Thus, this work presents a unique type of NCP-based drug delivery system with biodegradability, sensitive responses to light, as well as highly efficient tumor retention for effective cancer combinational treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Rotating Rod Renewable Microcolumns for Automated, Solid-Phase DNA Hybridization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruckner-Lea, Cynthia J.; Stottlemyre, Mark R.; Holman, David A.

    1999-12-01

    The development of a new temperature-controlled renewable microcolumn flow cell for solid-phase nucleic acid analysis in a sequential injection system is described. The flow cell includes a stepper motor-driven rotating rod with the working end cut to a 45 degree angle. In one position, the end of the rod prevents passage of microbeads while allowing fluid flow; rotation of the rod by 180 degrees release the beads. This system was used to rapidly test many hybridization and elution protocols to examine the temperature and solution conditions required for sequence specific nucleic acid hybridization. Target nucleic acids labeled with a near-infraredmore » fluorescent dye were detected immediately post-column using a flow-through fluorescence detector, with a detection limit of 40 pM dye concentration at a flow rate of 5 mu l/s. Temperature control of the column and the presence of Triton X-100 surfactant were critical for specific hybridization. Perfusion of the column with complementary oligonucleotide (200 mu l, 10nM) resulted in hybridization with 8% of the DNA binding sites on the microbeads with a solution residence time of less than a second and a total sample perfusion time of 40 seconds. The use of the renewable column system for detection of an unlabeled PCR product in a sandwich assay was also demonstrated.« less

  16. Comparison of computed radiography and conventional radiography in detection of small volume pneumoperitoneum.

    PubMed

    Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret

    2008-01-01

    The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.

  17. Hydrologic and geochemical data assimilation at the Hanford 300 Area

    NASA Astrophysics Data System (ADS)

    Chen, X.; Hammond, G. E.; Murray, C. J.; Zachara, J. M.

    2012-12-01

    In modeling the uranium migration within the Integrated Field Research Challenge (IFRC) site at the Hanford 300 Area, uncertainties arise from both hydrologic and geochemical sources. The hydrologic uncertainty includes the transient flow boundary conditions induced by dynamic variations in Columbia River stage and the underlying heterogeneous hydraulic conductivity field, while the geochemical uncertainty is a result of limited knowledge of the geochemical reaction processes and parameters, as well as heterogeneity in uranium source terms. In this work, multiple types of data, including the results from constant-injection tests, borehole flowmeter profiling, and conservative tracer tests, are sequentially assimilated across scales within a Bayesian framework to reduce the hydrologic uncertainty. The hydrologic data assimilation is then followed by geochemical data assimilation, where the goal is to infer the heterogeneous distribution of uranium sources using uranium breakthrough curves from a desorption test that took place at high spring water table. We demonstrate in our study that Ensemble-based data assimilation techniques (Ensemble Kalman filter and smoother) are efficient in integrating multiple types of data sequentially for uncertainty reduction. The computational demand is managed by using the multi-realization capability within the parallel PFLOTRAN simulator.

  18. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT.

    PubMed

    Wenz, Holger; Maros, Máté E; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Groden, Christoph; Henzler, Thomas

    2016-01-01

    To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1-5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1-5) when compared to sequential cCT with a mean SNR improvement of 44.77% (p < 0.0001). Spiral cCT combined with ATCM and IR allows for significant-radiation dose reduction including a reduce eye lens organ-dose when compared to a tilted sequential cCT while improving subjective and objective image quality.

  19. Concurrent versus sequential sorafenib therapy in combination with radiation for hepatocellular carcinoma.

    PubMed

    Wild, Aaron T; Gandhi, Nishant; Chettiar, Sivarajan T; Aziz, Khaled; Gajula, Rajendra P; Williams, Russell D; Kumar, Rachit; Taparra, Kekoa; Zeng, Jing; Cades, Jessica A; Velarde, Esteban; Menon, Siddharth; Geschwind, Jean F; Cosgrove, David; Pawlik, Timothy M; Maitra, Anirban; Wong, John; Hales, Russell K; Torbenson, Michael S; Herman, Joseph M; Tran, Phuoc T

    2013-01-01

    Sorafenib (SOR) is the only systemic agent known to improve survival for hepatocellular carcinoma (HCC). However, SOR prolongs survival by less than 3 months and does not alter symptomatic progression. To improve outcomes, several phase I-II trials are currently examining SOR with radiation (RT) for HCC utilizing heterogeneous concurrent and sequential treatment regimens. Our study provides preclinical data characterizing the effects of concurrent versus sequential RT-SOR on HCC cells both in vitro and in vivo. Concurrent and sequential RT-SOR regimens were tested for efficacy among 4 HCC cell lines in vitro by assessment of clonogenic survival, apoptosis, cell cycle distribution, and γ-H2AX foci formation. Results were confirmed in vivo by evaluating tumor growth delay and performing immunofluorescence staining in a hind-flank xenograft model. In vitro, concurrent RT-SOR produced radioprotection in 3 of 4 cell lines, whereas sequential RT-SOR produced decreased colony formation among all 4. Sequential RT-SOR increased apoptosis compared to RT alone, while concurrent RT-SOR did not. Sorafenib induced reassortment into less radiosensitive phases of the cell cycle through G1-S delay and cell cycle slowing. More double-strand breaks (DSBs) persisted 24 h post-irradiation for RT alone versus concurrent RT-SOR. In vivo, sequential RT-SOR produced the greatest tumor growth delay, while concurrent RT-SOR was similar to RT alone. More persistent DSBs were observed in xenografts treated with sequential RT-SOR or RT alone versus concurrent RT-SOR. Sequential RT-SOR additionally produced a greater reduction in xenograft tumor vascularity and mitotic index than either concurrent RT-SOR or RT alone. In conclusion, sequential RT-SOR demonstrates greater efficacy against HCC than concurrent RT-SOR both in vitro and in vivo. These results may have implications for clinical decision-making and prospective trial design.

  20. Concurrent versus Sequential Sorafenib Therapy in Combination with Radiation for Hepatocellular Carcinoma

    PubMed Central

    Chettiar, Sivarajan T.; Aziz, Khaled; Gajula, Rajendra P.; Williams, Russell D.; Kumar, Rachit; Taparra, Kekoa; Zeng, Jing; Cades, Jessica A.; Velarde, Esteban; Menon, Siddharth; Geschwind, Jean F.; Cosgrove, David; Pawlik, Timothy M.; Maitra, Anirban; Wong, John; Hales, Russell K.; Torbenson, Michael S.; Herman, Joseph M.; Tran, Phuoc T.

    2013-01-01

    Sorafenib (SOR) is the only systemic agent known to improve survival for hepatocellular carcinoma (HCC). However, SOR prolongs survival by less than 3 months and does not alter symptomatic progression. To improve outcomes, several phase I-II trials are currently examining SOR with radiation (RT) for HCC utilizing heterogeneous concurrent and sequential treatment regimens. Our study provides preclinical data characterizing the effects of concurrent versus sequential RT-SOR on HCC cells both in vitro and in vivo. Concurrent and sequential RT-SOR regimens were tested for efficacy among 4 HCC cell lines in vitro by assessment of clonogenic survival, apoptosis, cell cycle distribution, and γ-H2AX foci formation. Results were confirmed in vivo by evaluating tumor growth delay and performing immunofluorescence staining in a hind-flank xenograft model. In vitro, concurrent RT-SOR produced radioprotection in 3 of 4 cell lines, whereas sequential RT-SOR produced decreased colony formation among all 4. Sequential RT-SOR increased apoptosis compared to RT alone, while concurrent RT-SOR did not. Sorafenib induced reassortment into less radiosensitive phases of the cell cycle through G1-S delay and cell cycle slowing. More double-strand breaks (DSBs) persisted 24 h post-irradiation for RT alone versus concurrent RT-SOR. In vivo, sequential RT-SOR produced the greatest tumor growth delay, while concurrent RT-SOR was similar to RT alone. More persistent DSBs were observed in xenografts treated with sequential RT-SOR or RT alone versus concurrent RT-SOR. Sequential RT-SOR additionally produced a greater reduction in xenograft tumor vascularity and mitotic index than either concurrent RT-SOR or RT alone. In conclusion, sequential RT-SOR demonstrates greater efficacy against HCC than concurrent RT-SOR both in vitro and in vivo. These results may have implications for clinical decision-making and prospective trial design. PMID:23762417

  1. The Determination of Several Spray Characteristics of a High-Speed Oil Engine Injection System with an Oscilloscope

    NASA Technical Reports Server (NTRS)

    Hicks, Chester W; Moore, Charles S

    1928-01-01

    An investigation was conducted to determine the injection lag, duration of injection, and spray start and cut-off characteristics of a fuel injection system operated on an engine and injecting fuel into the atmosphere.

  2. An Apparatus for Measuring Rates of Discharge of a Fuel-Injection System

    NASA Technical Reports Server (NTRS)

    Dutee, Francis J

    1941-01-01

    A portable apparatus for rapidly determining rates of discharge of a fuel-injection system is described. Satisfactory operation of this apparatus with injection-pump speeds up to 2400 r.p.m was obtained. Rate-of-discharge tests were made with several cam-plunger-valve injection systems with long injection tubes. A check valve designed to reduce secondary discharges was tested. This check valve was operated with injection-pump speeds up to 2400 r.p.m without the occurrence of large secondary discharges.

  3. Multi-speed multi-phase resolver converter

    NASA Technical Reports Server (NTRS)

    Alhorn, Dean (Inventor); Howard, David (Inventor)

    1994-01-01

    A multiphase converter circuit generates a plurality of sinusoidal outputs of displaced phase and given speed value from the output of an angular resolver system attachable to a motor excited by these multi-phase outputs, the resolver system having a lower speed value than that of the motor. The angular resolver system provides in parallel format sequential digital numbers indicative of the amount of rotation of the shaft of an angular position sensor associated with the angular resolver system. These numbers are used to excite simultaneously identical addresses of a plurality of addressable memory systems, each memory system having stored therein at sequential addresses sequential values of a sinusoidal wavetrain of a given number of sinusoids. The stored wavetrain values represent sinusoids displaced from each other in phase according to the number of output phases desired. A digital-to-analog converter associated with each memory system converts each accessed word to a corresponding analog value to generate attendant to rotation of the angular resolver a sinusoidal wave of proper phase at each of the plurality of outputs. By properly orienting the angular resolver system with respect to the rotor of the motor, essentially ripple-free torque is supplied to the rotor. The angular resolver system may employ an analog resolver feeding an integrated circuit resolver-to-digital converter to produce the requisite digital values serving as addresses. Alternative versions employing incremental or absolute encoders are also described.

  4. Multi-speed multi-phase resolver converter

    NASA Technical Reports Server (NTRS)

    Alhorn, Dean C. (Inventor); Howard, David E. (Inventor)

    1995-01-01

    A multiphase converter circuit generates a plurality of sinusoidal outputs of displaced phase and given speed value from the output of an angular resolver system attachable to a motor excited by these multi-phase outputs, the resolver system having a lower speed value than that of the motor. The angular resolver system provides in parallel format sequential digital numbers indicative of the amount of rotation of the shaft of an angular position sensor associated with the angular resolver system. These numbers are used to excite simultaneously identical addresses of a plurality of addressable memory systems, each memory system having stored therein at sequential addresses sequential values of a sinusoidal wavetrain of a given number of sinusoids. The stored wavetrain values represent sinusoids displaced from each other in phase according to the number of output phases desired. A digital-to-analog converter associated with each memory system converts each accessed word to a corresponding analog value to generate attendant to rotation of the angular resolver a sinusoidal wave of proper phase at each of the plurality of outputs. By properly orienting the angular resolver system with respect to the rotor of the motor, essentially ripple-free torque is supplied to the rotor. The angular resolver system may employ an analog resolver feeding an integrated circuit resolver-to-digital converter to produce the requisite digital values serving as addresses. Alternative versions employing incremental or absolute encoders are also described.

  5. Coupled Reactive Transport Modeling of CO2 Injection in Mt. Simon Sandstone Formation, Midwest USA

    NASA Astrophysics Data System (ADS)

    Liu, F.; Lu, P.; Zhu, C.; Xiao, Y.

    2009-12-01

    CO2 sequestration in deep geological formations is one of the promising options for CO2 emission reduction. While several large scale CO2 injections in saline aquifers have shown to be successful for the short-term, there is still a lack of fundamental understanding on key issues such as CO2 storage capacity, injectivity, and security over multiple spatial and temporal scales that need to be addressed. To advance these understandings, we applied multi-phase coupled reactive mass transport modeling to investigate the fate of injected CO2 and reservoir responses to the injection into Mt. Simon Formation. We developed both 1-D and 2-D reactive transport models in a radial region of 10,000 m surrounding a CO2 injection well to represent the Mt. Simon sandstone formation, which is a major regional deep saline reservoir in the Midwest, USA. Supercritical CO2 is injected into the formation for 100 years, and the modeling continues till 10,000 years to monitor both short-term and long-term behavior of injected CO2 and the associated rock-fluid interactions. CO2 co-injection with H2S and SO2 is also simulated to represent the flue gases from coal gasification and combustion in the Illinois Basin. The injection of CO2 results in acidified zones (pH ~3 and 5) adjacent to the wellbore, causing progressive water-rock interactions in the surrounding region. In accordance with the extensive dissolution of authigenic K-feldspar, sequential precipitations of secondary carbonates and clay minerals are predicted in this zone. The vertical profiles of CO2 show fingering pattern from the top of the reservoir to the bottom due to the density variation of CO2-impregnated brine, which facilitate convection induced mixing and solubility trapping. Most of the injected CO2 remains within a radial distance of 2500 m at the end of 10,000 years and is sequestered and immobilized by solubility and residual trapping. Mineral trapping via secondary carbonates, including calcite, magnesite, ankerite and dawsonite, is predicted, but only constituting a minor component as compared to other trapping mechanisms. The mineral alteration induced by CO2 injection results in changes in porosity/permeability due to these complex mineral dissolution and precipitation reactions. Increases in porosity (from 15% to 16.2%) occur in the low-pH zones due to the acidic dissolution of minerals. However, within the carbonate mineral trapping zone, porosity reduction occurs. Co-injection of H2S causes relatively limited modification from the CO2 alone case while significantly higher water-rock reactivity is associated with the SO2 co-injection. Although co-injection of CO2 with H2S and SO2 could potentially reduce separation and injection cost, it may lead to some uncertainty and risks and therefore require further investigation.

  6. Towards simultaneous Talbot bands based optical coherence tomography and scanning laser ophthalmoscopy imaging.

    PubMed

    Marques, Manuel J; Bradu, Adrian; Podoleanu, Adrian Gh

    2014-05-01

    We report a Talbot bands-based optical coherence tomography (OCT) system capable of producing longitudinal B-scan OCT images and en-face scanning laser ophthalmoscopy (SLO) images of the human retina in-vivo. The OCT channel employs a broadband optical source and a spectrometer. A gap is created between the sample and reference beams while on their way towards the spectrometer's dispersive element to create Talbot bands. The spatial separation of the two beams facilitates collection by an SLO channel of optical power originating exclusively from the retina, deprived from any contribution from the reference beam. Three different modes of operation are presented, constrained by the minimum integration time of the camera used in the spectrometer and by the galvo-scanners' scanning rate: (i) a simultaneous acquisition mode over the two channels, useful for small size imaging, that conserves the pixel-to-pixel correspondence between them; (ii) a hybrid sequential mode, where the system switches itself between the two regimes and (iii) a sequential "on-demand" mode, where the system can be used in either OCT or SLO regimes for as long as required. The two sequential modes present varying degrees of trade-off between pixel-to-pixel correspondence and independent full control of parameters within each channel. Images of the optic nerve and fovea regions obtained in the simultaneous (i) and in the hybrid sequential mode (ii) are presented.

  7. Towards simultaneous Talbot bands based optical coherence tomography and scanning laser ophthalmoscopy imaging

    PubMed Central

    Marques, Manuel J.; Bradu, Adrian; Podoleanu, Adrian Gh.

    2014-01-01

    We report a Talbot bands-based optical coherence tomography (OCT) system capable of producing longitudinal B-scan OCT images and en-face scanning laser ophthalmoscopy (SLO) images of the human retina in-vivo. The OCT channel employs a broadband optical source and a spectrometer. A gap is created between the sample and reference beams while on their way towards the spectrometer’s dispersive element to create Talbot bands. The spatial separation of the two beams facilitates collection by an SLO channel of optical power originating exclusively from the retina, deprived from any contribution from the reference beam. Three different modes of operation are presented, constrained by the minimum integration time of the camera used in the spectrometer and by the galvo-scanners’ scanning rate: (i) a simultaneous acquisition mode over the two channels, useful for small size imaging, that conserves the pixel-to-pixel correspondence between them; (ii) a hybrid sequential mode, where the system switches itself between the two regimes and (iii) a sequential “on-demand” mode, where the system can be used in either OCT or SLO regimes for as long as required. The two sequential modes present varying degrees of trade-off between pixel-to-pixel correspondence and independent full control of parameters within each channel. Images of the optic nerve and fovea regions obtained in the simultaneous (i) and in the hybrid sequential mode (ii) are presented. PMID:24877006

  8. Planning and Instruction and the Social Studies Curriculum: A Discourse on Design and Delivery Systems.

    ERIC Educational Resources Information Center

    Peters, Richard

    A model for Continuous-Integrated-Sequential (C/I/S) curricula for social studies education is presented. The design advocated involves ensuring continuity of instruction from grades K-12, an integration of social studies disciplines, and a sequential process of refining and reinforcing concept and skills from grade-to-grade along the K-12…

  9. Exploiting Sequential Patterns Found in Users' Solutions and Virtual Tutor Behavior to Improve Assistance in ITS

    ERIC Educational Resources Information Center

    Fournier-Viger, Philippe; Faghihi, Usef; Nkambou, Roger; Nguifo, Engelbert Mephu

    2010-01-01

    We propose to mine temporal patterns in Intelligent Tutoring Systems (ITSs) to uncover useful knowledge that can enhance their ability to provide assistance. To discover patterns, we suggest using a custom, sequential pattern-mining algorithm. Two ways of applying the algorithm to enhance an ITS's capabilities are addressed. The first is to…

  10. System and method for detecting components of a mixture including tooth elements for alignment

    DOEpatents

    Sommer, Gregory Jon; Schaff, Ulrich Y.

    2016-11-22

    Examples are described including assay platforms having tooth elements. An impinging element may sequentially engage tooth elements on the assay platform to sequentially align corresponding detection regions with a detection unit. In this manner, multiple measurements may be made of detection regions on the assay platform without necessarily requiring the starting and stopping of a motor.

  11. Development of integrated control system for smart factory in the injection molding process

    NASA Astrophysics Data System (ADS)

    Chung, M. J.; Kim, C. Y.

    2018-03-01

    In this study, we proposed integrated control system for automation of injection molding process required for construction of smart factory. The injection molding process consists of heating, tool close, injection, cooling, tool open, and take-out. Take-out robot controller, image processing module, and process data acquisition interface module are developed and assembled to integrated control system. By adoption of integrated control system, the injection molding process can be simplified and the cost for construction of smart factory can be inexpensive.

  12. A Robust Real Time Direction-of-Arrival Estimation Method for Sequential Movement Events of Vehicles.

    PubMed

    Liu, Huawei; Li, Baoqing; Yuan, Xiaobing; Zhou, Qianwei; Huang, Jingchang

    2018-03-27

    Parameters estimation of sequential movement events of vehicles is facing the challenges of noise interferences and the demands of portable implementation. In this paper, we propose a robust direction-of-arrival (DOA) estimation method for the sequential movement events of vehicles based on a small Micro-Electro-Mechanical System (MEMS) microphone array system. Inspired by the incoherent signal-subspace method (ISM), the method that is proposed in this work employs multiple sub-bands, which are selected from the wideband signals with high magnitude-squared coherence to track moving vehicles in the presence of wind noise. The field test results demonstrate that the proposed method has a better performance in emulating the DOA of a moving vehicle even in the case of severe wind interference than the narrowband multiple signal classification (MUSIC) method, the sub-band DOA estimation method, and the classical two-sided correlation transformation (TCT) method.

  13. A controlled experiment on the impact of software structure on maintainability

    NASA Technical Reports Server (NTRS)

    Rombach, Dieter H.

    1987-01-01

    The impact of software structure on maintainability aspects including comprehensibility, locality, modifiability, and reusability in a distributed system environment is studied in a controlled maintenance experiment involving six medium-size distributed software systems implemented in LADY (language for distributed systems) and six in an extended version of sequential PASCAL. For all maintenance aspects except reusability, the results were quantitatively given in terms of complexity metrics which could be automated. The results showed LADY to be better suited to the development of maintainable software than the extension of sequential PASCAL. The strong typing combined with high parametrization of units is suggested to improve the reusability of units in LADY.

  14. Emulation study on system characteristic of high pressure common-rail fuel injection system for marine medium-speed diesel engine

    NASA Astrophysics Data System (ADS)

    Wang, Qinpeng; Yang, Jianguo; Xin, Dong; He, Yuhai; Yu, Yonghua

    2018-05-01

    In this paper, based on the characteristic analyzing of the mechanical fuel injection system for the marine medium-speed diesel engine, a sectional high-pressure common rail fuel injection system is designed, rated condition rail pressure of which is 160MPa. The system simulation model is built and the performance of the high pressure common rail fuel injection system is analyzed, research results provide the technical foundation for the system engineering development.

  15. A study of effects of electrode contacts on performance of organic-based light-emitting field-effect transistors

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Kyu; Choi, Jong-Ho

    2018-02-01

    Herein is presented a comparative performance analysis of heterojunction organic-based light-emitting field-effect transistors (OLEFETs) with symmetric (Au only) and asymmetric (Au and LiF/Al) electrode contacts. The devices had a top source-drain contact with long-channel geometry and were produced by sequentially depositing p-type pentacene and n-type N,N‧-ditridecylperylene-3,4,9,10-tetracarboxylic diimide (P13) using a neutral cluster beam deposition apparatus. The spectroscopic, structural and morphological properties of the organic thin films were examined using photoluminescence (PL) spectroscopy, X-ray diffraction (XRD) method, laser scanning confocal and atomic force microscopy (LSCM, AFM). Based upon the growth of high-quality, well-packed crystalline thin films, the devices demonstrated ambipolar field-effect characteristics, stress-free operational stability, and light emission under ambient conditions. Various device parameters were derived from the fits of the observed characteristics. The hole mobilities were nearly equal irrespective of the electrode contacts, whereas the electron mobilities of the transistors with LiF/Al drain electrodes were higher due to the low injection barrier. For the OLEFETs with symmetric electrodes, electroluminescence (EL) occurred only in the vicinity of the hole-injecting electrode, whereas for the OLEFETs with asymmetric electrodes, the emission occurred in the vicinity of both hole- and electron-injecting electrodes. By tuning the carrier injection and transport through high- and low-work function metals, the hole-electron recombination sites could be controlled. The operating conduction and light emission mechanism are discussed with the aid of EL images obtained using a charge-coupled device (CCD) camera.

  16. Sequential memory: Binding dynamics

    NASA Astrophysics Data System (ADS)

    Afraimovich, Valentin; Gong, Xue; Rabinovich, Mikhail

    2015-10-01

    Temporal order memories are critical for everyday animal and human functioning. Experiments and our own experience show that the binding or association of various features of an event together and the maintaining of multimodality events in sequential order are the key components of any sequential memories—episodic, semantic, working, etc. We study a robustness of binding sequential dynamics based on our previously introduced model in the form of generalized Lotka-Volterra equations. In the phase space of the model, there exists a multi-dimensional binding heteroclinic network consisting of saddle equilibrium points and heteroclinic trajectories joining them. We prove here the robustness of the binding sequential dynamics, i.e., the feasibility phenomenon for coupled heteroclinic networks: for each collection of successive heteroclinic trajectories inside the unified networks, there is an open set of initial points such that the trajectory going through each of them follows the prescribed collection staying in a small neighborhood of it. We show also that the symbolic complexity function of the system restricted to this neighborhood is a polynomial of degree L - 1, where L is the number of modalities.

  17. The involvement of immunoglobulin E isotype switch in scleroderma skin tissue.

    PubMed

    Ohtsuka, Tsutomu; Yamazaki, Soji

    2005-08-01

    The involvement of mast cell, which is activated by immunoglobulin E (IgE), has been reported in the formation of systemic sclerosis (SSc) abnormality. IgE is generated with isotype switch. During isotype switch, switch circles resulting from direct mu to epsilon, or from sequential mu to gamma via epsilon switching will be created. We studied whether switching occurs in SSc. We used nested polymerase chain reaction to analyze the S fragments from switch circles. Fifty-two patients with SSc, and 62 healthy women were studied. Neither of 62 normal skin tissues showed direct switch, nor sequential switch. Neither of seven normal whole blood cells showed direct switch, nor sequential switch. In 52SSc skin tissues, three (5.8%) showed direct switch, and two (3.8%) showed sequential switch. As a result, five (9.6%) of SSc skin tissue showed immunogobulin E class switch. These results were confirmed by DNA sequencing. These results demonstrated that isotype switch to the epsilon locus achieved by direct and/or sequential switch are involved in SSc skin.

  18. Sequential memory: Binding dynamics.

    PubMed

    Afraimovich, Valentin; Gong, Xue; Rabinovich, Mikhail

    2015-10-01

    Temporal order memories are critical for everyday animal and human functioning. Experiments and our own experience show that the binding or association of various features of an event together and the maintaining of multimodality events in sequential order are the key components of any sequential memories-episodic, semantic, working, etc. We study a robustness of binding sequential dynamics based on our previously introduced model in the form of generalized Lotka-Volterra equations. In the phase space of the model, there exists a multi-dimensional binding heteroclinic network consisting of saddle equilibrium points and heteroclinic trajectories joining them. We prove here the robustness of the binding sequential dynamics, i.e., the feasibility phenomenon for coupled heteroclinic networks: for each collection of successive heteroclinic trajectories inside the unified networks, there is an open set of initial points such that the trajectory going through each of them follows the prescribed collection staying in a small neighborhood of it. We show also that the symbolic complexity function of the system restricted to this neighborhood is a polynomial of degree L - 1, where L is the number of modalities.

  19. Bursts and Heavy Tails in Temporal and Sequential Dynamics of Foraging Decisions

    PubMed Central

    Jung, Kanghoon; Jang, Hyeran; Kralik, Jerald D.; Jeong, Jaeseung

    2014-01-01

    A fundamental understanding of behavior requires predicting when and what an individual will choose. However, the actual temporal and sequential dynamics of successive choices made among multiple alternatives remain unclear. In the current study, we tested the hypothesis that there is a general bursting property in both the timing and sequential patterns of foraging decisions. We conducted a foraging experiment in which rats chose among four different foods over a continuous two-week time period. Regarding when choices were made, we found bursts of rapidly occurring actions, separated by time-varying inactive periods, partially based on a circadian rhythm. Regarding what was chosen, we found sequential dynamics in affective choices characterized by two key features: (a) a highly biased choice distribution; and (b) preferential attachment, in which the animals were more likely to choose what they had previously chosen. To capture the temporal dynamics, we propose a dual-state model consisting of active and inactive states. We also introduce a satiation-attainment process for bursty activity, and a non-homogeneous Poisson process for longer inactivity between bursts. For the sequential dynamics, we propose a dual-control model consisting of goal-directed and habit systems, based on outcome valuation and choice history, respectively. This study provides insights into how the bursty nature of behavior emerges from the interaction of different underlying systems, leading to heavy tails in the distribution of behavior over time and choices. PMID:25122498

  20. Investigation of Multiphase Flow in a Packed Bed Reactor Under Microgravity Conditions

    NASA Technical Reports Server (NTRS)

    Lian, Yongsheng; Motil, Brian; Rame, Enrique

    2016-01-01

    In this paper we study the two-phase flow phenomena in a packed bed reactor using an integrated experimental and numerical method. The cylindrical bed is filled with uniformly sized spheres. In the experiment water and air are injected into the bed simultaneously. The pressure distribution along the bed will be measured. The numerical simulation is based on a two-phase flow solver which solves the Navier-Stokes equations on Cartesian grids. A novel coupled level set and moment of fluid method is used to construct the interface. A sequential method is used to position spheres in the cylinder. Preliminary experimental results showed that the tested flow rates resulted in pulse flow. The numerical simulation revealed that air bubbles could merge into larger bubbles and also could break up into smaller bubbles to pass through the pores in the bed. Preliminary results showed that flow passed through regions where the porosity is high. Comparison between the experimental and numerical results in terms of pressure distributions at different flow injection rates will be conducted. Comparison of flow phenomena under terrestrial gravity and microgravity will be made.

  1. Stochastic Model of Fracture Frequency Heterogeneity in a Welded Tuff EGS reservoir, Snake River Plain, Idaho, USA

    NASA Astrophysics Data System (ADS)

    Moody, A.; Fairley, J. P., Jr.

    2014-12-01

    In light of recent advancements in reservoir enhancement and injection tests at active geothermal fields, there is interest in investigating the geothermal potential of widespread subsurface welded tuffs related to caldera collapse on the Snake River Plain (SRP). Before considering stimulation strategies, simulating heat extraction from the reservoir under in-situ fracture geometries will give a first-order estimation of extractable heat. With only limited deep boreholes drilled on the SRP, few analyses of the bulk hydrologic properties of the tuffs exist. Acknowledging the importance of the spatial heterogeneity of fractures to the permeability and injectivity of reservoirs hosted in impermeable volcanic units, we present fracture distributions from ICDP hole 5036-2A drilled as a part of Project HOTSPOT. The core documents more than 1200 m of largely homogeneous densely welded tuff hosting an isothermal warm-water reservoir at ~60˚ C. Multiple realizations of a hypothetical reservoir are created using sequential indicator algorithms that honor the observed vertical fracture frequency statistics. Results help form criteria for producing geothermal energy from the SRP.

  2. A Bayesian sequential processor approach to spectroscopic portal system decisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sale, K; Candy, J; Breitfeller, E

    The development of faster more reliable techniques to detect radioactive contraband in a portal type scenario is an extremely important problem especially in this era of constant terrorist threats. Towards this goal the development of a model-based, Bayesian sequential data processor for the detection problem is discussed. In the sequential processor each datum (detector energy deposit and pulse arrival time) is used to update the posterior probability distribution over the space of model parameters. The nature of the sequential processor approach is that a detection is produced as soon as it is statistically justified by the data rather than waitingmore » for a fixed counting interval before any analysis is performed. In this paper the Bayesian model-based approach, physics and signal processing models and decision functions are discussed along with the first results of our research.« less

  3. Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

    NASA Technical Reports Server (NTRS)

    Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)

    1973-01-01

    An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

  4. Autologous fat grafting: use of closed syringe microcannula system for enhanced autologous structural grafting

    PubMed Central

    Alexander, Robert W; Harrell, David B

    2013-01-01

    Objectives Provide background for use of acquiring autologous adipose tissue as a tissue graft and source of adult progenitor cells for use in cosmetic plastic surgery. Discuss the background and mechanisms of action of closed syringe vacuum lipoaspiration, with emphasis on accessing adipose-derived mesenchymal/stromal cells and the stromal vascular fraction (SVF) for use in aesthetic, structural reconstruction and regenerative applications. Explain a proven protocol for acquiring high-quality autologous fat grafts (AFG) with use of disposable, microcannula systems. Design Explain the components and advantage of use of the patented super luer-lock and microcannulas system for use with the closed-syringe system. A sequential explanation of equipment selection for minimally traumatic lipoaspiration in small volumes is presented, including use of blunt injection cannulas to reduce risk of embolism. Results Thousands of AFG have proven safe and efficacious for lipoaspiration techniques for large and small structural fat grafting procedures. The importance and advantages of gentle harvesting of the adipose tissue complex has become very clear in the past 5 years. The closed-syringe system offers a minimally invasive, gentle system with which to mobilize subdermal fat tissues in a suspension form. Resulting total nuclear counting of undifferentiated cells of the adipose-derived -SVF suggests that the yield achieved is better than use of always-on, constant mechanical pump applied vacuum systems. Conclusion Use of a closed-syringe lipoaspiration system featuring disposable microcannulas offers a safe and effective means of harvesting small volumes of nonmanipulated adipose tissues and its accompanying progenitor cells within the SVF. Closed syringes and microcannulas are available as safe, sterile, disposable, compact systems for acquiring high-quality AFG. Presented is a detailed, step-by-step, proven protocol for performing quality autologous structural adipose transplantation. PMID:23630430

  5. Electrokinetic injection techniques in microfluidic chips.

    PubMed

    Fu, L M; Yang, R J; Lee, G B; Liu, H H

    2002-10-01

    The separation efficiency of a microfluidic chip is influenced to a significant degree by the flow field conditions within the injection microchannel. Therefore, an understanding of the physics of the flow within this channel is beneficial in the design and operation of such a system. The configuration of an injection system is determined by the volume of the sample plug that is to be delivered to the separation process. Accordingly, this paper addresses the design and testing of injection systems with a variety of configurations, including a simple cross, a double-T, and a triple-T configuration. This paper also presents the design of a unique multi-T injection configuration. Each injection system cycles through a predetermined series of steps, in which the electric field magnitude and distribution within the various channels is strictly manipulated, to effectuate a virtual valve. The uniquemulti-T configuration injection system presented within this paper has the ability to simulate the functions of the cross, double-T, and triple-T systems through appropriate manipulations of the electric field within its various channels. In other words, the proposed design successfully combines several conventional injection systems within a single microfluidic chip.

  6. The Intelligent Management System: An Overview.

    DTIC Science & Technology

    1982-12-07

    comprises of hundreds of subprocesses concerned with bulb grasping, positioning, heating, cooling, etc. Each is sequentially related with others in time...activity. Activity schemata can be constructed into a network to define both parallel and sequential precedence, and hierarchical to describe...The flow of work is controlled by the "operation- lineup " associated with the product being manufactured. The operation- lineup specifies the sequence of

  7. Bluff Body Fuel Mixer

    NASA Technical Reports Server (NTRS)

    Cheung, Albert K. (Inventor); Hoke, James B. (Inventor); McKinney, Randal G. (Inventor)

    2017-01-01

    A combustor is provided. The combustor may include an axial fuel injection system, and a radial fuel injection system aft of the axial fuel injection system. The axial fuel injection system includes a mixer having a bluff body at an exit port of the mixer, and a fuel injector disposed within the mixer. A fuel and air mixer is also provided and comprises an outer housing with an exit port and a bluff body. The bluff body extends across the exit port of the outer housing. A fuel injection system is also provided. The systems comprise a mixer having a bluff body at an exit port of the mixer and a fuel injector disposed within the mixer.

  8. Capsule injection system for a hydraulic capsule pipelining system

    DOEpatents

    Liu, Henry

    1982-01-01

    An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.

  9. Development of a low-flow multiplexed interface for capillary electrophoresis/electrospray ion trap mass spectrometry using sequential spray.

    PubMed

    Chen, Chao-Jung; Li, Fu-An; Her, Guor-Rong

    2008-05-01

    A multiplexed CE-MS interface using four low-flow sheath liquid ESI sprayers has been developed. Because of the limited space between the low-flow sprayers and the entrance aperture of the ESI source, multichannel analysis is difficult using conventional rotating plate approaches. Instead, a multiplexed low-flow system was achieved by applying an ESI potential sequentially to the four low-flow sprayers, resulting in only one sprayer being sprayed at any given time. The synchronization of the scan event and the voltage relays was accomplished by using the data acquisition signal from the IT mass spectrometer. This synchronization resulted in the ESI voltage being sequentially applied to each of the four sprayers according to the corresponding scan event. With this design, a four-fold increase in analytical throughput was achieved. Because of the use of low-flow interfaces, this multiplexed system has superior sensitivity than a rotating plate design using conventional sheath liquid interfaces. The multiplexed design presented has the potential to be applied to other low-flow multiplexed systems, such as multiplexed capillary LC and multiplexed CEC.

  10. Performance Modeling and Measurement of Parallelized Code for Distributed Shared Memory Multiprocessors

    NASA Technical Reports Server (NTRS)

    Waheed, Abdul; Yan, Jerry

    1998-01-01

    This paper presents a model to evaluate the performance and overhead of parallelizing sequential code using compiler directives for multiprocessing on distributed shared memory (DSM) systems. With increasing popularity of shared address space architectures, it is essential to understand their performance impact on programs that benefit from shared memory multiprocessing. We present a simple model to characterize the performance of programs that are parallelized using compiler directives for shared memory multiprocessing. We parallelized the sequential implementation of NAS benchmarks using native Fortran77 compiler directives for an Origin2000, which is a DSM system based on a cache-coherent Non Uniform Memory Access (ccNUMA) architecture. We report measurement based performance of these parallelized benchmarks from four perspectives: efficacy of parallelization process; scalability; parallelization overhead; and comparison with hand-parallelized and -optimized version of the same benchmarks. Our results indicate that sequential programs can conveniently be parallelized for DSM systems using compiler directives but realizing performance gains as predicted by the performance model depends primarily on minimizing architecture-specific data locality overhead.

  11. NASA DOE POD NDE Capabilities Data Book

    NASA Technical Reports Server (NTRS)

    Generazio, Edward R.

    2015-01-01

    This data book contains the Directed Design of Experiments for Validating Probability of Detection (POD) Capability of NDE Systems (DOEPOD) analyses of the nondestructive inspection data presented in the NTIAC, Nondestructive Evaluation (NDE) Capabilities Data Book, 3rd ed., NTIAC DB-97-02. DOEPOD is designed as a decision support system to validate inspection system, personnel, and protocol demonstrating 0.90 POD with 95% confidence at critical flaw sizes, a90/95. The test methodology used in DOEPOD is based on the field of statistical sequential analysis founded by Abraham Wald. Sequential analysis is a method of statistical inference whose characteristic feature is that the number of observations required by the procedure is not determined in advance of the experiment. The decision to terminate the experiment depends, at each stage, on the results of the observations previously made. A merit of the sequential method, as applied to testing statistical hypotheses, is that test procedures can be constructed which require, on average, a substantially smaller number of observations than equally reliable test procedures based on a predetermined number of observations.

  12. ROSSTEP v1.3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allevato, Adam

    2016-07-21

    ROSSTEP is a system for sequentially running roslaunch, rosnode, and bash scripts automatically, for use in Robot Operating System (ROS) applications. The system consists of YAML files which define actions and conditions. A python file parses the code and runs actions sequentially using the sys and subprocess python modules. Between actions, it uses various ROS-based code to check conditions required to proceed, and only moves on to the next action when all the necessary conditions have been met. Included is rosstep-creator, a QT application designed to create the YAML files required for ROSSTEP. It has a nearly one-to-one mapping frommore » interface elements to YAML output, and serves as a convenient GUI for working with the ROSSTEP system.« less

  13. Video systems for real-time oil-spill detection

    NASA Technical Reports Server (NTRS)

    Millard, J. P.; Arvesen, J. C.; Lewis, P. L.; Woolever, G. F.

    1973-01-01

    Three airborne television systems are being developed to evaluate techniques for oil-spill surveillance. These include a conventional TV camera, two cameras operating in a subtractive mode, and a field-sequential camera. False-color enhancement and wavelength and polarization filtering are also employed. The first of a series of flight tests indicates that an appropriately filtered conventional TV camera is a relatively inexpensive method of improving contrast between oil and water. False-color enhancement improves the contrast, but the problem caused by sun glint now limits the application to overcast days. Future effort will be aimed toward a one-camera system. Solving the sun-glint problem and developing the field-sequential camera into an operable system offers potential for color 'flagging' oil on water.

  14. Hybrid and concatenated coding applications.

    NASA Technical Reports Server (NTRS)

    Hofman, L. B.; Odenwalder, J. P.

    1972-01-01

    Results of a study to evaluate the performance and implementation complexity of a concatenated and a hybrid coding system for moderate-speed deep-space applications. It is shown that with a total complexity of less than three times that of the basic Viterbi decoder, concatenated coding improves a constraint length 8 rate 1/3 Viterbi decoding system by 1.1 and 2.6 dB at bit error probabilities of 0.0001 and one hundred millionth, respectively. With a somewhat greater total complexity, the hybrid coding system is shown to obtain a 0.9-dB computational performance improvement over the basic rate 1/3 sequential decoding system. Although substantial, these complexities are much less than those required to achieve the same performances with more complex Viterbi or sequential decoder systems.

  15. Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts from urban dust and diesel standard reference materials using a 2D-LC/2D-GC system.

    PubMed

    Ahmed, Trifa M; Lim, Hwanmi; Bergvall, Christoffer; Westerholm, Roger

    2013-10-01

    A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.

  16. Design and Testing of Trace Contaminant Injection and Monitoring Systems

    NASA Technical Reports Server (NTRS)

    Broerman, Craig D.; Sweterlitsch, Jeff

    2009-01-01

    In support of the Carbon dioxide And Moisture Removal Amine Swing-bed (CAMRAS) testing, a contaminant injection system as well as a contaminant monitoring system has been developed by the Johnson Space Center Air Revitalization Systems (JSC-ARS) team. The contaminant injection system has been designed to provide trace level concentrations of contaminants generated by humans in a closed environment during space flight missions. The contaminant injection system continuously injects contaminants from three gas cylinders, two liquid reservoirs and three permeation ovens. The contaminant monitoring system has been designed to provide real time gas analysis with accurate flow, humidity and gas concentration measurements for collection during test. The contaminant monitoring system consists of an analytical real time gas analyzer, a carbon monoxide sensor, and an analyzer for ammonia and water vapor.

  17. Dabigatran for the prevention of stroke and systemic embolism in atrial fibrillation: A NICE single technology appraisal.

    PubMed

    Faria, Rita; Spackman, Eldon; Burch, Jane; Corbacho, Belen; Todd, Derick; Pepper, Chris; Woolacott, Nerys; Palmer, Stephen

    2013-07-01

    The National Institute for Health and Clinical Excellence (NICE) invited the manufacturer of dabigatran etexilate (Boehringer Ingelheim Ltd, UK) to submit evidence for the clinical and cost-effectiveness of this drug for the prevention of stroke and systemic embolism in patients with non-valvular atrial fibrillation (AF) as part of the NICE single technology appraisal process. The Centre for Reviews and Dissemination and the Centre for Health Economics at the University of York were commissioned to act as the evidence review group (ERG). This article presents a summary of the manufacturer's submission, the ERG report and the subsequent development of NICE guidance for the use of dabigatran within the UK National Health Service. Dabigatran was granted marketing authorisation by the European Medicines Agency for a sequential dosing regimen (DBG sequential), in which patients under 80 years are treated with dabigatran 150 mg twice daily (DBG150) and patients 80 years and over are given dabigatran 110 mg twice daily (DBG110). NICE decisions are bound by the marketing authorisation; therefore, the decision problem faced by the committee was whether the DBG sequential regimen was effective and cost-effective compared with warfarin or aspirin for patients with non-valvular AF and one or more risk factors. The RE-LY trial, a large multi-centre non-inferiority randomised clinical trial, was the primary source of clinical evidence. DBG150 was shown to be non-inferior, and subsequently superior to warfarin, for the primary outcome of all stroke/systemic embolism. DBG110 was found to be non-inferior to warfarin. Results were presented for a post hoc subgroup analysis for patients under and over 80 years of age, where DBG110 showed a statistically significant reduction of haemorrhagic stroke and intracranial haemorrhage in comparison to warfarin in patients over 80 years of age. This post hoc subgroup analysis by age was the basis for the licensed DBG sequential regimen. The economic evaluation compared the costs and outcomes of DBG110, DBG150 and DBG sequential against warfarin, aspirin, and aspirin plus clopidogrel. Across the three dosing regimens, dabigatran was associated with greater costs and better health outcomes than warfarin; however, DBG150 offered the most benefits and dominated DBG110 and DBG sequential (i.e. less costly and more effective). The cost-effectiveness of DBG150 was less favourable for patients well controlled on warfarin. In the first appraisal meeting, the committee issued a 'minded no' decision until additional analyses on the licensed DBG sequential regimen were presented by the manufacturer. These additional analyses indicated that the incremental cost-effectiveness ratio (ICER) of the DBG sequential regimen compared with warfarin ranged from £8,388 to £18,987 per quality-adjusted life year (QALY) gained depending on the level of monitoring costs assumed for warfarin. Patients on warfarin would need to be within therapeutic range 83-85 % of the time for the ICER to exceed £30,000 per additional QALY. Following consideration of the additional evidence and the responses from a large number of consultees and commentators, the committee recommended dabigatran as DBG sequential as an option for the prevention of stroke and systemic embolism in people with non-valvular AF with one or more risk factors for ischaemic stroke.

  18. Intrapleural combination therapy with lobaplatin and erythromycin for non-small cell lung cancer-mediated malignant pleural effusion.

    PubMed

    Xu, Lisheng; Wang, Benjie; Gao, Meimei; Zhang, Yan; Qi, Qian; Li, Tao; Li, Caiyu; Wang, Aihua; Li, Yu

    2018-06-19

    Malignant pleural effusion is a common complication of non-small cell lung cancer (NSCLC); however, treatment options remain limited. This study evaluated the safety and efficacy of sequential intrapleural therapy with lobaplatin and erythromycin for NSCLC-mediated malignant pleural effusion. Fifty-six patients with NSCLC complicated with malignant pleural effusion were recruited for a prospective single-arm study from December 2014 to 2016; one patient dropped out. In addition to conventional systemic chemotherapy, lobaplatin and erythromycin were intrapleurally injected into subjects. Short and long-term responses were analyzed. The concentration of ultrafilterable platinum in the pleural effusion and plasma were detected at different time points. Incidences of severe adverse reactions were observed. In the 55 evaluable patients, the effective rate of pleural effusion was 81.8% after six weeks of treatment. Six and twelve months after treatment, the effective rates were 60% and 21.8%, respectively, and the one-year survival rate was 83.6%. The concentrations of lobaplatin in pleural effusion and plasma two hours after injecting 50 mg lobaplatin into the thoracic cavity were 13.763 ± 1.523 μg/mL and 1.120 ± 0.164 μg/mL, and 17 hours later were 1.961 ± 0.351 μg/mL and 0.578 ± 0.095 μg/mL, respectively. The rate of severe adverse reactions of the first cycle of systemic chemotherapy combined with lobaplatin and erythromycin did not significantly differ from the rate in the second cycle. Intrapleural combination therapy with lobaplatin and erythromycin is a safe and efficient treatment for patients with NSCLC-mediated malignant pleural effusion. © 2018 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  19. Nonlinear Fluid Migration Patterns in Fractured Reservoirs due to Stress-Pressure Coupling induced Changes in Reservoir Permeabilities

    NASA Astrophysics Data System (ADS)

    Annewandter, R.; Geiger, S.; Main, I. G.

    2011-12-01

    Sustainable storage of carbon dioxide (CO2) requires a thorough understanding of injection induced pressure build-up and its effects on the storage formation's integrity, since it determines the cap rock's sealing properties as well as the total storable amount of carbon dioxide. Fractures are abundant in the subsurface and difficult to detect due to their subseismic characteristic. If present in the cap during injection, they can be primary pathways for CO2 leakage. The North Sea is considered as Europe's most important carbon dioxide storage area. However, almost all of the potential storage formations have been exposed to post-glacial lithospheric flexure, possibly causing the generation of new fracture networks in the overburden whilst rebounding. Drawing upon, fast carbon dioxide uprise can be facilitated due to opening of fractures caused by changes in the stress field over time. The overall effective permeability, and hence possible leakage rates, of a fractured storage formation is highly sensitive to the fracture aperture which itself depends on the far field and in situ stress field. For this reason, our in-house general purpose reservoir simulator Complex System Modeling Platform (CSMP++) has been expanded, which is particularly designed to simulate multiphase flow on fractured porous media. It combines finite element (FE) and finite volume (FV) methods on mixed-dimensional hybrid-element meshes. The unstructured FE-FV based scheme allows us to model complex geological structures, such as fractures, at great detail. The simulator uses a compositional model for NaCl-H2O-CO2-systems for compressible fluids for computing thermophysical properties as a function of formation pressure and temperature. A fixed stress-split sequential procedure is being used to calculate coupled fluid flow and geomechanics. Numerical proof of concept studies will be presented showing the impact of fracture opening and closure on fluid migration patterns due to coupled stress-pressure induced changes in effective permeabilities.

  20. Spacecraft Data Simulator for the test of level zero processing systems

    NASA Technical Reports Server (NTRS)

    Shi, Jeff; Gordon, Julie; Mirchandani, Chandru; Nguyen, Diem

    1994-01-01

    The Microelectronic Systems Branch (MSB) at Goddard Space Flight Center (GSFC) has developed a Spacecraft Data Simulator (SDS) to support the development, test, and verification of prototype and production Level Zero Processing (LZP) systems. Based on a disk array system, the SDS is capable of generating large test data sets up to 5 Gigabytes and outputting serial test data at rates up to 80 Mbps. The SDS supports data formats including NASA Communication (Nascom) blocks, Consultative Committee for Space Data System (CCSDS) Version 1 & 2 frames and packets, and all the Advanced Orbiting Systems (AOS) services. The capability to simulate both sequential and non-sequential time-ordered downlink data streams with errors and gaps is crucial to test LZP systems. This paper describes the system architecture, hardware and software designs, and test data designs. Examples of test data designs are included to illustrate the application of the SDS.

  1. A dynamic two-dimensional system for measuring volatile organic compound volatilization and movement in soils.

    PubMed

    Allaire, S E; Yates, S R; Ernst, F F; Gan, J

    2002-01-01

    There is an important need to develop instrumentation that allows better understanding of atmospheric emission of toxic volatile compounds associated with soil management. For this purpose, chemical movement and distribution in the soil profile should be simultaneously monitored with its volatilization. A two-dimensional rectangular soil column was constructed and a dynamic sequential volatilization flux chamber was attached to the top of the column. The flux chamber was connected through a manifold valve to a gas chromatograph (GC) for real-time concentration measurement. Gas distribution in the soil profile was sampled with gas-tight syringes at selected times and analyzed with a GC. A pressure transducer was connected to a scanivalve to automatically measure the pressure distribution in the gas phase of the soil profile. The system application was demonstrated by packing the column with a sandy loam in a symmetrical bed-furrow system. A 5-h furrow irrigation was started 24 h after the injection of a soil fumigant, propargyl bromide (3-bromo-1-propyne; 3BP). The experience showed the importance of measuring lateral volatilization variability, pressure distribution in the gas phase, chemical distribution between the different phases (liquid, gas, and sorbed), and the effect of irrigation on the volatilization. Gas movement, volatilization, water infiltration, and distribution of degradation product (Br-) were symmetric around the bed within 10%. The system saves labor cost and time. This versatile system can be modified and used to compare management practices, estimate concentration-time indexes for pest control, study chemical movement, degradation, and emissions, and test mathematical models.

  2. Safety of three sequential whole bladder photodynamic therapy (WBPDT) treatments in the management of resistant bladder cancer

    NASA Astrophysics Data System (ADS)

    Mejia, Maria C.; Nseyo, Unyime O.

    2009-02-01

    INTRODUCTION: WBPDT has been used to treat resistant superficial bladder cancer, with clinical benefits and associated dose-dependent side effects. OBJECTIVE: The objective of this study was to assess the safety of three sequential WBPDT treatments in patients with resistant non-muscle invasive (NMI) bladder cancer. MATERIALS AND METHODS: 12 males and one female provided written informed consent in this Phase II study. Each patient received intravenous injection of Photofrin® (AXCAN Parma Inc, Canada) at 1.5 mg/kg two days prior to whole bladder laser (630nm) treatment. Assessment of safety and efficacy included weekly urinary symptoms; cystoscopy, biopsy and cytology; and measurement of bladder volume quarterly after each treatment at baseline, six and 12 months. Treatment #2 and/or #3 occurred only in the absence of bladder contracture, and/or disease progression. RESULTS: 13 patients: 12 males and one female have been enrolled and average age of enrollees is 67.1(52 - 87) years. Four patients had Ta-T1/Grade I-III tumors; two patients had CIS associated with T1/GI-III; and seven patients had carcinoma in situ (CIS) only. Three patients received 3/3 treatments, and are evaluable for toxicity; three patients received two treatments only; and seven patients received one treatment only. There was no bladder contracture; transient mild to moderate bladder irritative voiding symptoms of dysuria, urinary frequency, nocturia and urgency occurred in all patients. The three evaluable patients were without evidence of disease at average of 13.1 (7-20) months. CONCLUSION: Three sequential WBPDT treatments might have a favorable toxicity profile in the management of recurrent/ refractory non-muscle invasive bladder cancer.

  3. [Revascularization of left anterior descending artery area using a skeletonized left internal mammary artery: a comparison between sequential and separate grafting].

    PubMed

    Shen, J Q; Ji, Q; Ding, W J; Xia, L M; Wei, L; Wang, C S

    2018-03-13

    Objective: To evaluate in-hospital and mid-term outcomes of sequential versus separate grafting of in situ skeletonized left internal mammary artery (LIMA) to the left coronary system in a single-center, propensity-matched study. Methods: After propensity score matching, 120 pairs of patients undergoing first, scheduled, isolated coronary artery bypass grafting (CABG) with in situ skeletonized LIMA grafting to the left anterior descending artery (LAD) territory were entered into a sequential group (sequential grafting of LIMA to the diagonal artery and then to the LAD) or a control group (separate grafting of LIMA to the LAD). The in-hospital and follow-up clinical outcomes and follow-up LIMA graft patency were compared. Results: The two propensity score-matched groups had similar in-hospital and follow-up clinical outcomes. The number of bypass conduits ranged from 3 to 6 (with a mean of 3.5), and 91.3%(219/240)of the included patients received off-pump CABG surgery. No significant differences were found between the two propensity score-matched groups in the in-hospital outcomes, including in-hospital death and the incidence of complications associated with CABG (prolonged ventilation, peroperative stroke, re-operation before discharge, and deep sternal wound infection). During follow-up, 9 patients (4 patients from the sequential group and 5 patients from the control group) died, and the all-cause mortality rate was 3.9%. No significant difference was found in the all-cause mortality rate between the 2 groups[3.4% (4/116) vs 4.3% (5/115), P =0.748]. During follow-up period, 99.1% (115/116) patency for the diagonal site and 98.3% (114/116) for the LAD site were determined by coronary computed tomographic angiography after sequential LIMA grafting, both of which were similar with graft patency of separate grafting of in situ skeletonized LIMA to the LAD. Conclusions: Revascularization of the left coronary system using a skeletonized LIMA resulted in excellent in-hospital and mid-term clinical outcomes and graft patency using sequential grafting.

  4. Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET.

    PubMed

    Schepis, Tiziano; Gaemperli, Oliver; Treyer, Valerie; Valenta, Ines; Burger, Cyrill; Koepfli, Pascal; Namdar, Mehdi; Adachi, Itaru; Alkadhi, Hatem; Kaufmann, Philipp A

    2007-11-01

    The aim of this study was to compare 2-dimensional (2D) and 3-dimensional (3D) dynamic PET for the absolute quantification of myocardial blood flow (MBF) with (13)N-ammonia ((13)N-NH(3)). 2D and 3D MBF measurements were collected from 21 patients undergoing cardiac evaluation at rest (n = 14) and during standard adenosine stress (n = 7). A lutetium yttrium oxyorthosilicate-based PET/CT system with retractable septa, enabling the sequential acquisition of 2D and 3D images within the same patient and study, was used. All 2D studies were performed by injecting 700-900 MBq of (13)N-NH(3). For 14 patients, 3D studies were performed with the same injected (13)N-NH(3) dose as that used in 2D studies. For the remaining 7 patients, 3D images were acquired with a lower dose of (13)N-NH(3), that is, 500 MBq. 2D images reconstructed by use of filtered backprojection (FBP) provided the reference standard for MBF measurements. 3D images were reconstructed by use of Fourier rebinning (FORE) with FBP (FORE-FBP), FORE with ordered-subsets expectation maximization (FORE-OSEM), and a reprojection algorithm (RP). Global MBF measurements derived from 3D PET with FORE-FBP (r = 0.97), FORE-OSEM (r = 0.97), and RP (r = 0.97) were well correlated with those derived from 2D FBP (all Ps < 0.0001). The mean +/- SD differences in global MBF measurements between 3D FORE-FBP and 2D FBP and between 3D FORE-OSEM and 2D FBP were 0.01 +/- 0.14 and 0.01 +/- 0.15 mL/min/g, respectively. The mean +/- SD difference in global MBF measurements between 3D RP and 2D FBP was 0.00 +/- 0.16 mL/min/g. The best correlation between 2D PET and 3D PET performed with the lower injected activity was found for the 3D FORE-FBP reconstruction algorithm (r = 0.95, P < 0.001). For this scanner type, quantitative measurements of MBF with 3D PET and (13)N-NH(3) were in excellent agreement with those obtained with the 2D technique, even when a lower activity was injected.

  5. Safeguarding a Lunar Rover with Wald's Sequential Probability Ratio Test

    NASA Technical Reports Server (NTRS)

    Furlong, Michael; Dille, Michael; Wong, Uland; Nefian, Ara

    2016-01-01

    The virtual bumper is a safeguarding mechanism for autonomous and remotely operated robots. In this paper we take a new approach to the virtual bumper system by using an old statistical test. By using a modified version of Wald's sequential probability ratio test we demonstrate that we can reduce the number of false positive reported by the virtual bumper, thereby saving valuable mission time. We use the concept of sequential probability ratio to control vehicle speed in the presence of possible obstacles in order to increase certainty about whether or not obstacles are present. Our new algorithm reduces the chances of collision by approximately 98 relative to traditional virtual bumper safeguarding without speed control.

  6. Dynamics of Sequential Decision Making

    NASA Astrophysics Data System (ADS)

    Rabinovich, Mikhail I.; Huerta, Ramón; Afraimovich, Valentin

    2006-11-01

    We suggest a new paradigm for intelligent decision-making suitable for dynamical sequential activity of animals or artificial autonomous devices that depends on the characteristics of the internal and external world. To do it we introduce a new class of dynamical models that are described by ordinary differential equations with a finite number of possibilities at the decision points, and also include rules solving this uncertainty. Our approach is based on the competition between possible cognitive states using their stable transient dynamics. The model controls the order of choosing successive steps of a sequential activity according to the environment and decision-making criteria. Two strategies (high-risk and risk-aversion conditions) that move the system out of an erratic environment are analyzed.

  7. Discharge characteristics of a high speed fuel injection system

    NASA Technical Reports Server (NTRS)

    Matthews, Robertson

    1925-01-01

    Discussed here are some discharge characteristics of a fuel injection system intended primarily for high speed service. The system consisted of a cam actuated fuel pump, a spring loaded automatic injection valve, and a connecting tube.

  8. Reductant injection and mixing system

    DOEpatents

    Reeves, Matt; Henry, Cary A.; Ruth, Michael J.

    2016-02-16

    A gaseous reductant injection and mixing system is described herein. The system includes an injector for injecting a gaseous reductant into an exhaust gas stream, and a mixer attached to a surface of the injector. The injector includes a plurality of apertures through which the gaseous reductant is injected into an exhaust gas stream. The mixer includes a plurality of fluid deflecting elements.

  9. Microcontroller-driven fluid-injection system for atomic force microscopy.

    PubMed

    Kasas, S; Alonso, L; Jacquet, P; Adamcik, J; Haeberli, C; Dietler, G

    2010-01-01

    We present a programmable microcontroller-driven injection system for the exchange of imaging medium during atomic force microscopy. Using this low-noise system, high-resolution imaging can be performed during this process of injection without disturbance. This latter circumstance was exemplified by the online imaging of conformational changes in DNA molecules during the injection of anticancer drug into the fluid chamber.

  10. Poster error probability in the Mu-11 Sequential Ranging System

    NASA Technical Reports Server (NTRS)

    Coyle, C. W.

    1981-01-01

    An expression is derived for the posterior error probability in the Mu-2 Sequential Ranging System. An algorithm is developed which closely bounds the exact answer and can be implemented in the machine software. A computer simulation is provided to illustrate the improved level of confidence in a ranging acquisition using this figure of merit as compared to that using only the prior probabilities. In a simulation of 20,000 acquisitions with an experimentally determined threshold setting, the algorithm detected 90% of the actual errors and made false indication of errors on 0.2% of the acquisitions.

  11. Inverse problems in 1D hemodynamics on systemic networks: a sequential approach.

    PubMed

    Lombardi, D

    2014-02-01

    In this work, a sequential approach based on the unscented Kalman filter is applied to solve inverse problems in 1D hemodynamics, on a systemic network. For instance, the arterial stiffness is estimated by exploiting cross-sectional area and mean speed observations in several locations of the arteries. The results are compared with those ones obtained by estimating the pulse wave velocity and the Moens-Korteweg formula. In the last section, a perspective concerning the identification of the terminal models parameters and peripheral circulation (modeled by a Windkessel circuit) is presented. Copyright © 2013 John Wiley & Sons, Ltd.

  12. 40 CFR 49.4164 - Construction and operational control measures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... closed-vent system to: (i) An operating system designed to recover and inject all the produced natural... through a closed-vent system to: (i) An operating system designed to recover and inject the natural gas... operating system designed to recover and inject natural gas becomes temporarily infeasible and there is no...

  13. 40 CFR 49.4164 - Construction and operational control measures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... closed-vent system to: (i) An operating system designed to recover and inject all the produced natural... through a closed-vent system to: (i) An operating system designed to recover and inject the natural gas... operating system designed to recover and inject natural gas becomes temporarily infeasible and there is no...

  14. Daily subcutaneous parecoxib injection for cancer pain: an open label pilot study.

    PubMed

    Kenner, David J; Bhagat, Sandeep; Fullerton, Sonia L

    2015-04-01

    Nonsteroidal anti-inflammatory analgesics (NSAIDs) are useful in cancer pain but the specific use of subcutaneous parecoxib has not been previously reported. This pilot study aimed to establish the efficacy and side effect profile of short-term sequential single daily dose subcutaneous parecoxib sodium in patients with severe cancer bone pain. Nineteen hospitalized patients with advanced cancer and uncontrolled malignant bone pain (9 males, 10 females) received 24 courses of one, two, or three days sequential therapy with 'off-label' daily subcutaneous parecoxib. All patients were receiving opioid therapy; the median baseline daily oral equivalent dose (OED) of morphine was 180 mg. Pain was assessed at baseline, 24 hours, 48 hours, and 72 hours. Pain scores as assessed on an 11-point numeric pain rating scale (NPRS), any side effects including subcutaneous site reactions, as well as patient satisfaction rating with analgesia were recorded. A clinically significant decrease in pain scores was defined as a reduction of two or more points on the NPRS. Median pain score of all patient treatments decreased from 7 to 4.5 at 24 hours (p<0.001) and 4.0 at 48 hours. A response was seen in 17 (71%) of the 24 treatments at 24 hours. There was no difference between median negative change in pain scores in 19 (79%) treatments where pain was either strongly movement related, or in 22 (94%) treatments where local bone tenderness was more pronounced. No major side effects were observed during treatment. One patient died from pulmonary embolism after cessation of concurrent prophylactic low molecular weight heparin prior to staging liver biopsy. Subcutaneous site reactions occurred in 2 (8%) treatments and were mild and self limiting. Short-term daily subcutaneous parecoxib injection was effective for malignant bone pain when added to existing analgesic therapy and was well tolerated. Further research is warranted into the short-term use of parecoxib in hospitalized patients with intractable malignant bone pain.

  15. Rapid Intradeformational Emplacement of the Big Hole Canyon Pluton Into the Sevier Fold-Thrust Belt, Southwest Montana.

    NASA Astrophysics Data System (ADS)

    Hespenheide, M. A.

    2002-12-01

    The Big Hole Canyon pluton (BHCp) is a Late Cretaceous pluton emplaced within the Sevier fold-and-thrust belt of the western North American Cordillera. The pluton is exposed over 60km2 and a thickness of ~1400m. Combined anisotropy of magnetic susceptibility (AMS), structural, and field studies document a clear pattern of magmatic flow radiating from at least three subvertical conduits <100m wide and ~300 to ~800m long. Interpreted flow plunges change rapidly to subhorizontal fabrics across the rest of the pluton, matching the expected pattern for laccolithic emplacement. Ascent conduits within the Big Hole Canyon pluton are coincident with the fold axis of an anticline above a thrust ramp, suggesting that the magma ascended up the fault of the fault-bend-fold. Geobarometry and stratigraphic reconstructions indicate an emplacement depth of approximately ~3km. Preliminary thermal modeling indicates that the BHCp was emplaced in 250,000 years, likely between periods of regional shortening deformation. Rapid magma ascent rates calculated by dike flow modeling and implied by entrained wall-rock xenoliths may indicate sequential magma injection into the pluton; an absence of chill margins between phases within the pluton indicates that sequential injections must have taken place quickly enough that the magmas did not have time to cool below the solidus temperature. The geometry and location of the BHCp suggest that magma used a pre-existing fault as a mechanical discontinuity for both ascent and emplacement. Continued intrusion of magma had a sufficient amount of driving pressure to stretch, shear, and lift the roof of the pluton. Detailed field mapping, structural studies, AMS, and thermobarometry indicate that the Late Cretaceous Big Hole Canyon pluton was emplaced as a laccolith at the top of a pre-existing fault-bend-fold in the frontal portion of the Sevier fold-thrust belt.

  16. Influence of pre-injection control parameters on main-injection fuel quantity for an electronically controlled double-valve fuel injection system of diesel engine

    NASA Astrophysics Data System (ADS)

    Song, Enzhe; Fan, Liyun; Chen, Chao; Dong, Quan; Ma, Xiuzhen; Bai, Yun

    2013-09-01

    A simulation model of an electronically controlled two solenoid valve fuel injection system for a diesel engine is established in the AMESim environment. The accuracy of the model is validated through comparison with experimental data. The influence of pre-injection control parameters on main-injection quantity under different control modes is analyzed. In the spill control valve mode, main-injection fuel quantity decreases gradually and then reaches a stable level because of the increase in multi-injection dwell time. In the needle control valve mode, main-injection fuel quantity increases with rising multi-injection dwell time; this effect becomes more obvious at high-speed revolutions and large main-injection pulse widths. Pre-injection pulse width has no obvious influence on main-injection quantity under the two control modes; the variation in main-injection quantity is in the range of 1 mm3.

  17. Forced guidance and distribution of practice in sequential information processing.

    NASA Technical Reports Server (NTRS)

    Decker, L. R.; Rogers, C. A., Jr.

    1973-01-01

    Distribution of practice and forced guidance were used in a sequential information-processing task in an attempt to increase the capacity of human information-processing mechanisms. A reaction time index of the psychological refractory period was used as the response measure. Massing of practice lengthened response times while forced guidance shortened them. Interpretation was in terms of load reduction upon the response-selection stage of the information-processing system.-

  18. Sequential continuous flow processes for the oxidation of amines and azides by using HOF·MeCN.

    PubMed

    McPake, Christopher B; Murray, Christopher B; Sandford, Graham

    2012-02-13

    The generation and use of the highly potent oxidising agent HOF·MeCN in a controlled single continuous flow process is described. Oxidations of amines and azides to corresponding nitrated systems by using fluorine gas, water and acetonitrile by sequential gas-liquid/liquid-liquid continuous flow procedures are reported. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Sequential and prosodic design of English and Greek non-valenced news receipts.

    PubMed

    Kaimaki, Marianna

    2012-03-01

    Results arising from a prosodic and interactional study of the organization of everyday talk in English suggest that news receipts can be grouped into two categories: valenced (e.g., oh good) and non-valenced (e.g., oh really). In-depth investigation of both valenced and non-valenced news receipts shows that differences in their prosodic design do not seem to affect the sequential structure of the news informing sequence. News receipts with falling and rising pitch may have the same uptake and are treated in the same way by co-participants. A preliminary study of a Greek telephone corpus yielded the following receipts of news announcements: a malista, a(h) orea, a ne, a, oh. These are news markers composed of a standalone particle or a particle followed by an adverb or a response token (ne). Analysis of the sequential and prosodic design of Greek news announcement sequences is made to determine any interactional patterns and/or prosodic constraints. By examining the way in which co-participants display their interpretation of these turns I show that the phonological systems of contrast are different depending on the sequential environment, in much the same way that consonantal systems of contrast are not the same syllable initially and finally.

  20. Parallelization of sequential Gaussian, indicator and direct simulation algorithms

    NASA Astrophysics Data System (ADS)

    Nunes, Ruben; Almeida, José A.

    2010-08-01

    Improving the performance and robustness of algorithms on new high-performance parallel computing architectures is a key issue in efficiently performing 2D and 3D studies with large amount of data. In geostatistics, sequential simulation algorithms are good candidates for parallelization. When compared with other computational applications in geosciences (such as fluid flow simulators), sequential simulation software is not extremely computationally intensive, but parallelization can make it more efficient and creates alternatives for its integration in inverse modelling approaches. This paper describes the implementation and benchmarking of a parallel version of the three classic sequential simulation algorithms: direct sequential simulation (DSS), sequential indicator simulation (SIS) and sequential Gaussian simulation (SGS). For this purpose, the source used was GSLIB, but the entire code was extensively modified to take into account the parallelization approach and was also rewritten in the C programming language. The paper also explains in detail the parallelization strategy and the main modifications. Regarding the integration of secondary information, the DSS algorithm is able to perform simple kriging with local means, kriging with an external drift and collocated cokriging with both local and global correlations. SIS includes a local correction of probabilities. Finally, a brief comparison is presented of simulation results using one, two and four processors. All performance tests were carried out on 2D soil data samples. The source code is completely open source and easy to read. It should be noted that the code is only fully compatible with Microsoft Visual C and should be adapted for other systems/compilers.

  1. Monitoring of subsurface injection of wastes, Florida

    USGS Publications Warehouse

    Vecchioli, John

    1979-01-01

    Injection of waste liquids into Florida's subsurface is physically feasible in many places but should be accompanied by monitoring of the waste-receiving aquifer system in addition to the injection facility. Monitoring of the interaction of factors including hydrogeologic conditions, well construction, waste volumes and characteristics, and potable-water sources is desirable to assure that fresh-water resources are not being adversely affected. An effective aquifer-system monitoring program includes on-site wells located close to an injection well and open to the next-higher permeable stratum, satellite wells located hundreds to several thousands of feet from an injection well and open to the receiving aquifer, and regional wells located miles from individual injection wells and open to the receiving aquifer. An extensive aquifer-system monitoring program associated with two waste-injection facilities near Pensacola, Florida, has provided data which have aided hydrologists to understand the aquifer system's response to the injection and, accordingly, to evaluate the potential for affecting the area's fresh-water resources.

  2. Advanced Turbo-Charging Research and Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2008-02-27

    The objective of this project is to conduct analysis, design, procurement and test of a high pressure ratio, wide flow range, and high EGR system with two stages of turbocharging. The system needs to meet the stringent 2010MY emissions regulations at 20% + better fuel economy than its nearest gasoline competitor while allowing equivalent vehicle launch characteristics and higher torque capability than its nearest gasoline competitor. The system will also need to meet light truck/ SUV life requirements, which will require validation or development of components traditionally used only in passenger car applications. The conceived system is termed 'seriessequential turbocharger'more » because the turbocharger system operates in series at appropriate times and also sequentially when required. This is accomplished using intelligent design and control of flow passages and valves. Components of the seriessequential system will also be applicable to parallel-sequential systems which are also expected to be in use for future light truck/SUV applications.« less

  3. Design and construction of a double inversion recombination switch for heritable sequential genetic memory.

    PubMed

    Ham, Timothy S; Lee, Sung K; Keasling, Jay D; Arkin, Adam P

    2008-07-30

    Inversion recombination elements present unique opportunities for computing and information encoding in biological systems. They provide distinct binary states that are encoded into the DNA sequence itself, allowing us to overcome limitations posed by other biological memory or logic gate systems. Further, it is in theory possible to create complex sequential logics by careful positioning of recombinase recognition sites in the sequence. In this work, we describe the design and synthesis of an inversion switch using the fim and hin inversion recombination systems to create a heritable sequential memory switch. We have integrated the two inversion systems in an overlapping manner, creating a switch that can have multiple states. The switch is capable of transitioning from state to state in a manner analogous to a finite state machine, while encoding the state information into DNA. This switch does not require protein expression to maintain its state, and "remembers" its state even upon cell death. We were able to demonstrate transition into three out of the five possible states showing the feasibility of such a switch. We demonstrate that a heritable memory system that encodes its state into DNA is possible, and that inversion recombination system could be a starting point for more complex memory circuits. Although the circuit did not fully behave as expected, we showed that a multi-state, temporal memory is achievable.

  4. Design and Construction of a Double Inversion Recombination Switch for Heritable Sequential Genetic Memory

    PubMed Central

    Ham, Timothy S.; Lee, Sung K.; Keasling, Jay D.; Arkin, Adam P.

    2008-01-01

    Background Inversion recombination elements present unique opportunities for computing and information encoding in biological systems. They provide distinct binary states that are encoded into the DNA sequence itself, allowing us to overcome limitations posed by other biological memory or logic gate systems. Further, it is in theory possible to create complex sequential logics by careful positioning of recombinase recognition sites in the sequence. Methodology/Principal Findings In this work, we describe the design and synthesis of an inversion switch using the fim and hin inversion recombination systems to create a heritable sequential memory switch. We have integrated the two inversion systems in an overlapping manner, creating a switch that can have multiple states. The switch is capable of transitioning from state to state in a manner analogous to a finite state machine, while encoding the state information into DNA. This switch does not require protein expression to maintain its state, and “remembers” its state even upon cell death. We were able to demonstrate transition into three out of the five possible states showing the feasibility of such a switch. Conclusions/Significance We demonstrate that a heritable memory system that encodes its state into DNA is possible, and that inversion recombination system could be a starting point for more complex memory circuits. Although the circuit did not fully behave as expected, we showed that a multi-state, temporal memory is achievable. PMID:18665232

  5. Economics of water injected air screw compressor systems

    NASA Astrophysics Data System (ADS)

    Venu Madhav, K.; Kovačević, A.

    2015-08-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  6. Parametric performance analysis of steam-injected gas turbine with a thermionic-energy-converter-lined combustor

    NASA Technical Reports Server (NTRS)

    Choo, Y. K.; Burns, R. K.

    1982-01-01

    The performance of steam-injected gas turbines having combustors lined with thermionic energy converters (STIG/TEC systems) was analyzed and compared with that of two baseline systems; a steam-injected gas turbine (without a TEC-lined combustor) and a conventional combined gas turbine/steam turbine cycle. Common gas turbine parameters were assumed for all of the systems. Two configurations of the STIG/TEC system were investigated. In both cases, steam produced in an exhaust-heat-recovery boiler cools the TEC collectors. It is then injected into the gas combustion stream and expanded through the gas turbine. The STIG/TEC system combines the advantage of gas turbine steam injection with the conversion of high-temperature combustion heat by TEC's. The addition of TEC's to the baseline steam-injected gas turbine improves both its efficiency and specific power. Depending on system configuration and design parameters, the STIG/TEC system can also achieve higher efficiency and specific power than the baseline combined cycle.

  7. Penetration and Duration of Fuel Sprays from a Pump Injection System

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Marsh, E T

    1931-01-01

    High-speed motion pictures were taken of individual fuel sprays from a pump injection system. The changes in the spray-tip penetration with changes in the pump speed, injection-valve opening and closing pressures, discharge-orifice area, injection-tube length and diameter, and pump throttle setting were measured. In addition, the effects of the variables on the time lag and duration of injection can be controlled by the dimensions of the injection tube, the area of the discharge orifice, and the injection-valve opening and closing pressures.

  8. A Novel Ship-Tracking Method for GF-4 Satellite Sequential Images.

    PubMed

    Yao, Libo; Liu, Yong; He, You

    2018-06-22

    The geostationary remote sensing satellite has the capability of wide scanning, persistent observation and operational response, and has tremendous potential for maritime target surveillance. The GF-4 satellite is the first geostationary orbit (GEO) optical remote sensing satellite with medium resolution in China. In this paper, a novel ship-tracking method in GF-4 satellite sequential imagery is proposed. The algorithm has three stages. First, a local visual saliency map based on local peak signal-to-noise ratio (PSNR) is used to detect ships in a single frame of GF-4 satellite sequential images. Second, the accuracy positioning of each potential target is realized by a dynamic correction using the rational polynomial coefficients (RPCs) and automatic identification system (AIS) data of ships. Finally, an improved multiple hypotheses tracking (MHT) algorithm with amplitude information is used to track ships by further removing the false targets, and to estimate ships’ motion parameters. The algorithm has been tested using GF-4 sequential images and AIS data. The results of the experiment demonstrate that the algorithm achieves good tracking performance in GF-4 satellite sequential images and estimates the motion information of ships accurately.

  9. Development of a multilayered association polymer system for sequential drug delivery

    NASA Astrophysics Data System (ADS)

    Chinnakavanam Sundararaj, Sharath kumar

    As all the physiological processes in our body are controlled by multiple biomolecules, comprehensive treatment of certain disease conditions may be more effectively achieved by administration of more than one type of drug. Thus, the primary objective of this research was to develop a multilayered, polymer-based system for sequential delivery of multiple drugs. This particular device was designed aimed at the treatment of periodontitis, a highly prevalent oral inflammatory disease that affects 90% of the world population. This condition is caused by bacterial biofilm on the teeth, resulting in a chronic inflammatory response that leads to loss of alveolar bone and, ultimately, the tooth. Current treatment methods for periodontitis address specific parts of the disease, with no individual treatment serving as a complete therapy. The polymers used for the fabrication of this multilayered device consists of cellulose acetate phthalate (CAP) complexed with Pluronic F-127 (P). After evaluating morphology of the resulting CAPP system, in vitro release of small molecule drugs and a model protein was studied from both single and multilayered devices. Drug release from single-layered CAPP films followed zero-order kinetics related to surface erosion property of the association polymer. Release studies from multilayered CAPP devices showed the possibility of achieving intermittent release of one type of drug as well as sequential release of more than one type of drug. Mathematical modeling accurately predicted the release profiles for both single layer and multilayered devices. After the initial characterization of the CAPP system, the device was specifically modified to achieve sequential release of drugs aimed at the treatment of periodontitis. The four types of drugs used were metronidazole, ketoprofen, doxycycline, and simvastatin to eliminate infection, inhibit inflammation, prevent tissue destruction, and aid bone regeneration, respectively. To obtain different erosion times and achieve appropriate release profiles specific to the disease condition, the device was modified by increasing the number of layers or by inclusion of a slower eroding polymer layer. In all the cases, the device was able to release the four different drugs in the designed temporal sequence. Analysis of antibiotic and antiinflammatory bioactivity showed that drugs released from the devices retained 100% bioactivity. Following extensive studies on the in vitro sequential drug release from these devices, the in vivo drug release profiles were investigated. The CAPP devices with different release rates and dosage formulations were implanted in a rat calvarial onlay model, and the in vivo drug release and erosion was compared with in vitro results. In vivo studies showed sequential release of drugs comparable to those measured in vitro, with some difference in drug release rates observed. The present CAPP association polymer-based multilayer devices can be used for localized, sequential delivery of multiple drugs for the possible treatment of complex disease conditions, and perhaps for tissue engineering applications, that require delivery of more than one type of biomolecule. KEYWORDS: Multiple drug delivery, Periodontitis, Cellulose acetate phthalate, Pluronic F-127, Sequential drug release, in vitro drug release, in vivo drug release.

  10. Dual fuel injection piggyback controller system

    NASA Astrophysics Data System (ADS)

    Muji, Siti Zarina Mohd.; Hassanal, Muhammad Amirul Hafeez; Lee, Chua King; Fawzi, Mas; Zulkifli, Fathul Hakim

    2017-09-01

    Dual-fuel injection is an effort to reduce the dependency on diesel and gasoline fuel. Generally, there are two approaches to implement the dual-fuel injection in car system. The first approach is changing the whole injector of the car engine, the consequence is excessive high cost. Alternatively, it also can be achieved by manipulating the system's control signal especially the Electronic Control Unit (ECU) signal. Hence, the study focuses to develop a dual injection timing controller system that likely adopted to control injection time and quantity of compressed natural gas (CNG) and diesel fuel. In this system, Raspberry Pi 3 reacts as main controller unit to receive ECU signal, analyze it and then manipulate its duty cycle to be fed into the Electronic Driver Unit (EDU). The manipulation has changed the duty cycle to two pulses instead of single pulse. A particular pulse mainly used to control injection of diesel fuel and another pulse controls injection of Compressed Natural Gas (CNG). The test indicated promising results that the system can be implemented in the car as piggyback system. This article, which was originally published online on 14 September 2017, contained an error in the acknowledgment section. The corrected acknowledgment appears in the Corrigendum attached to the pdf.

  11. Parallelization of NAS Benchmarks for Shared Memory Multiprocessors

    NASA Technical Reports Server (NTRS)

    Waheed, Abdul; Yan, Jerry C.; Saini, Subhash (Technical Monitor)

    1998-01-01

    This paper presents our experiences of parallelizing the sequential implementation of NAS benchmarks using compiler directives on SGI Origin2000 distributed shared memory (DSM) system. Porting existing applications to new high performance parallel and distributed computing platforms is a challenging task. Ideally, a user develops a sequential version of the application, leaving the task of porting to new generations of high performance computing systems to parallelization tools and compilers. Due to the simplicity of programming shared-memory multiprocessors, compiler developers have provided various facilities to allow the users to exploit parallelism. Native compilers on SGI Origin2000 support multiprocessing directives to allow users to exploit loop-level parallelism in their programs. Additionally, supporting tools can accomplish this process automatically and present the results of parallelization to the users. We experimented with these compiler directives and supporting tools by parallelizing sequential implementation of NAS benchmarks. Results reported in this paper indicate that with minimal effort, the performance gain is comparable with the hand-parallelized, carefully optimized, message-passing implementations of the same benchmarks.

  12. Comparison between sequentional treatment with diode and alexandrite lasers versus alexandrite laser alone in the treatment of hirsutism.

    PubMed

    Nilforoushzadeh, Mohammad Ali; Naieni, Farahnaz Fatemi; Siadat, Amir Hossein; Rad, Leila

    2011-11-01

    Laser systems that are commonly used for the treatment of hirsutism include the ruby laser (694 nm), the diode laser (800 nm), the alexandrite laser (755 nm) and the Nd:YAG laser (1084 nm). The diode laser and alexandrite laser are considered effective in treatment of hirsutism in dark-skinned patients. The response of hairs to these laser systems is variable and not complete. In this study, we compared the efficacy of these two laser systems for permanent hair removal. This was a randomized, controlled clinical trial that was performed with women of the age range 15-45 years old. After obtaining informed consent, the samples were randomized into two groups using random allocation software. The first group was treated with alexandrite laser alone (four sessions, two months apart). The second group was treated sequentially with diode laser for the first two sessions and alexandrite laser for the next two sessions. Overall, 111 patients (57 patients in the alexandrite laser group and 54 patients in the sequential diode-alexandrite laser group) were evaluated. There was no significant difference regarding mean of hair reduction between the two groups during the courses of treatment. Except for the first session, there was no significant difference regarding percent of patient satisfaction between the two groups (P value >0.05). Comparison between the two groups showed no significant difference one month, three months and six months after the last treatment (P value >0.05). Regarding the results of our study, there is no significant difference between sequential treatment with diode and alexandrite lasers versus alexandrite laser alone in the treatment of hirsutism. We suggest that in further studies, the efficacy of sequential treatment with other laser systems is evaluated against single treatment methods.

  13. Hypertension study in anaesthetized rabbits: protocol proposal for AT1 antagonists screening.

    PubMed

    Politi, Aggeliki P; Zervou, Maria V; Triantafyllidi, Helen; Zoumpoulakis, Panagiotis G; Mavromoustakos, Thomas M; Zoga, Anastasia A; Moutevelis-Minakakis, Panagiota; Kokotos, George; Iliodromitis, Efstathios K; Kremastinos, Dimitris Th

    2010-06-01

    The aim of this study was to establish an optimized fast and safe protocol for the pharmacological screening of AT(1) antagonists. The pharmaceutical prototype AT(1) antagonist losartan, its active metabolite EXP3174 and the synthetic compound MMK1 were analysed in order to validate the protocol. Ang II was continuously infused while the animals received the drugs in two procedures. In the post-treatment procedure drugs were administered either in a single bolus dose or in a sequential manner. When losartan was administered in a single bolus dose, efficacy was evident until the 7th min (p=0.012) whilst EXP3174 infusion extended the efficiency up to the end of the study (p=0.006). In addition, the sequential injections of losartan prolonged the inhibitory time interval until the end of the study (p=0.045). In the pre-treatment procedure, results suggested a dose-dependent inhibitory effect for both antagonists. The pressor response to Ang II was unchanged after MMK1 administration either in the post- or in the pre-treatment mode. The proposed protocol appears to be safe, simple and fast for the pharmacological screening of AT(1) antagonists and enables the evaluation of new antagonists using lower doses than any other reported in the literature.

  14. Perilymph pharmacokinetics of marker applied through a cochlear implant in guinea pigs

    PubMed Central

    Hartsock, Jared; Gill, Ruth; Smyth, Daniel; Kirk, Jonathon; Verhoeven, Kristien

    2017-01-01

    Patients undergoing cochlear implantation could benefit from a simultaneous application of drugs into the ear, helping preserve residual low-frequency hearing and afferent nerve fiber populations. One way to apply drugs is to incorporate a cannula into the implant, through which drug solution is driven. For such an approach, perilymph concentrations achieved and the distribution in the ear over time have not previously been documented. We used FITC-labeled dextran as a marker, delivering it into perilymph of guinea pigs at 10 or 100 nL/min though a cannula incorporated into a cochlear implant with the outlet in the mid basal turn. After injections of varying duration (2 hours, 1 day or 7 days) perilymph was collected from the cochlear apex using a sequential sampling technique, allowing dextran levels and gradients along scala tympani to be quantified. Data were interpreted quantitatively using computer simulations of the experiments. For injections of 2 hours duration, dextran levels were critically influenced by the presence or absence of fluid leakage at the cochleostomy site. When the cochleostomy was fluid-tight, substantially higher perilymph levels were achieved at the injection site, with concentration declining along scala tympani towards the apex. Contrary to expectations, large dextran gradients along scala tympani persisted after 24 hours of sustained injection and were still present in some animals after 7 days injection. Functional changes associated with implantation and dextran delivery, and the histological state of the implant and cannula were also documented. The persistent longitudinal gradients of dextan along the ear were not readily explained by computer simulations of the experiments based on prior pharmacokinetic data. One explanation is that inner ear pharmacokinetics are altered in the period after cochlear implantation, possibly by a permeabilization of the blood-labyrinth barrier as part of the immune response to the implant. PMID:28817653

  15. Simulating Bioremediation of Chloroethenes in a Fractured Rock Aquifer.

    NASA Astrophysics Data System (ADS)

    Curtis, G. P.

    2016-12-01

    Reactive transport simulations are being conducted to synthesize the results of a field experiment on the enhanced bioremediation of chloroethenes in a heterogeneous fractured-rock aquifer near West Trenton, NJ. The aquifer consists of a sequence of dipping mudstone beds, with water-conducting bedding-plane fractures separated by low-permeability rock where transport is diffusion-limited. The enhanced bioremediation experiment was conducted by injecting emulsified vegetable oil as an electron donor (EOS™) and a microbial consortium (KB1™) that contained dehalococcoides ethenogenes into a fracture zone that had maximum trichloroethene (TCE) concentrations of 84µM. TCE was significantly biodegraded to dichloroethene, chloroethene and ethene or CO2 at the injection well and at a downgradient well. The results also show the concomitant reduction of Fe(III) and S(6) and the production of methane . The results were used to calibrate transport models for quantifying the dominant mass-removal mechanisms. A nonreactive transport model was developed to simulate advection, dispersion and matrix diffusion of bromide and deuterium tracers present in the injection solution. This calibrated model matched tracer concentrations at the injection well and a downgradient observation well and demonstrated that matrix diffusion was a dominant control on tracer transport. A reactive transport model was developed to extend the nonreactive transport model to simulate the microbially mediated sequential dechlorination reactions, reduction of Fe(III) and S(6), and methanogenesis. The reactive transport model was calibrated to concentrations of chloride, chloroethenes, pH, alkalinity, redox-sensitive species and major ions, to estimate key biogeochemical kinetic parameters. The simulation results generally match the diverse set of observations at the injection and observation wells throughout the three year experiment. In addition, the observations and model simulations indicate that a significant pool of TCE that was initially sorbed to either the fracture surfaces or in the matrix was degraded during the field experiment. The calibrated reactive transport model will be used to quantify the extent of chloroethene mass removal from a range of hypothetical aquifers.

  16. Comparison of pressure-controlled provocation discography using automated versus manual syringe pump manometry in patients with chronic low back pain.

    PubMed

    Derby, Richard; Lee, Sang Hoon; Lee, Jeong-Eun; Lee, Sang-Heon

    2011-01-01

    The study compares the rate of positive discograms using an automated versus a manual pressure-controlled injection devise and compares the pressure and volume values at various pressures and initial evoked pain and 6/10 or greater evoked pain. A retrospective study prospectively collected patient study data used in a prior prospective study and with prospectively collected data which is routinely collected per our institutional standardized audit protocol. Two custom-built disc manometers (automated injection speed control; manual injection speed control) were sequentially employed during provocation discography in 510 discs of 151 consecutive patients. Two hundred thirty-seven discs of 67 patients with chronic low back pain were evaluated using the automated manometer (automated group) and 273 discs of 84 patients were evaluated with a manual manometer (manual group). No significant differences in positive discogram rates were found between the automated and manual groups (32.1% vs 32.6% per disc, respectively, P>0.05). No significant differences in low-pressure positive discogram rates were found (16.0% vs 15.0% per disc, automated group versus manual group, respectively, P>0.05). However, there were significantly increased volumes and lower pressures at initial and "bad" pain provocation. The study results found equivalent positive discogram rates following a series of pressure-controlled discography using either an automated or manual pressure devise. There were, however significant increases in volume at both initial onset of evoked pain and at 6/10 pain when using the automated injection devise that may have caused the observed lower opening pressure and lower pressure values at initial evoked pain. Assuming increased volumes are innocuous, automated injection is inherently more controlled and may better reduce unintended and often unrecorded spurious high dynamic pressure peaks thereby reducing conscious and unconscious operator bias. Wiley Periodicals, Inc.

  17. An Injectable, Self-Healing Hydrogel to Repair the Central Nervous System.

    PubMed

    Tseng, Ting-Chen; Tao, Lei; Hsieh, Fu-Yu; Wei, Yen; Chiu, Ing-Ming; Hsu, Shan-hui

    2015-06-17

    An injectable, self-healing hydrogel (≈1.5 kPa) is developed for healing nerve-system deficits. Neurosphere-like progenitors proliferate in the hydrogel and differentiate into neuron-like cells. In the zebrafish injury model, the central nervous system function is partially rescued by injection of the hydrogel and significantly rescued by injection of the neurosphere-laden hydrogel. The self-healing hydrogel may thus potentially repair the central nervous system. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Fibrous membranes in diabetic retinopathy and bevacizumab.

    PubMed

    Pattwell, David M; Stappler, Theodor; Sheridan, Carl; Heimann, Heinrich; Gibran, Syed K; Wong, David; Hiscott, Paul

    2010-01-01

    The purpose of this study was to determine the histopathologic characteristics of bevacizumab-treated human proliferative diabetic retinopathy (PDR) membranes with particular regard to membrane vasculature as a step toward addressing the effects of the drug on PDR membranes. Intravitreous injection of bevacizumab, an antivascular endothelial growth factor monoclonal antibody, has recently been advocated as an adjunct in surgery for PDR. In this context, a clinically observed decrease in PDR epiretinal membrane vascularity (vascular regression) occurs from 24 hours to 48 hours after injection, but the exact mechanisms of drug action are unknown. A consecutive series of seven PDR membrane specimens that had been removed sequentially from seven bevacizumab-treated patients were studied retrospectively. The membrane specimens were examined using light microscopic methods, including immunohistochemistry. Five of the seven membranes were clinically avascular (one contained "ghost" vessels) and did not hemorrhage during excision. Of these 5 specimens, which included 1 removed 7 days after a total of 6 intravitreous injections of 1.25 mg bevacizumab, 4 contained histologically detectable capillaries (1 did not). These blood vessels were lined by endothelial cells as determined by immunohistochemistry for the endothelial markers CD31 and CD34. The two remaining membranes were clinically and histologically still vascularized despite bevacizumab treatment. All the specimens also contained smooth muscle actin-containing fibroblastic cells within the collagenous stroma. The findings do not support the concept that the clinical phenomenon of vascular regression in PDR membranes after bevacizumab injection in the vitreous is resulting from obliteration of the membrane blood vessels. Another mechanism appears to be involved in at least some patients, possibly a vasoconstrictive response. Such a mechanism might explain reversal of the effects of bevacizumab that has been reported after this treatment.

  19. Multimodal fusion imaging ensemble for targeted sentinel lymph node management: initial results of an innovative promising approach for anatomically difficult lymphatic drainage in different tumour entities.

    PubMed

    Maza, Sofiane; Taupitz, Mathias; Taymoorian, Kasra; Winzer, Klaus Jürgen; Rückert, Jens; Paschen, Christian; Räber, Gert; Schneider, Sylke; Trefzer, Uwe; Munz, Dieter L

    2007-03-01

    There are situations where exact identification and localisation of sentinel lymph nodes (SLNs) are very difficult using lymphoscintigraphy, a hand-held gamma probe and vital dye, either a priori or a posteriori. We developed a new method using a simultaneous injection of two lymphotropic agents for exact topographical tomographic localisation and biopsy of draining SLNs. The purpose of this prospective pilot study was to investigate the feasibility and efficacy of this method ensemble. Fourteen patients with different tumour entities were enrolled. A mixture of (99m)Tc-nanocolloid and a dissolved superparamagnetic iron oxide was injected interstitially. Dynamic, sequential static lymphoscintigraphy and SPECT served as pathfinders. MR imaging was performed 2 h after injection. SPECT, contrast MRI and, if necessary, CT scan data sets were fused and evaluated with special regard to the topographical location of SLNs. The day after injection, nine patients underwent SLN biopsy and, in the presence of SLN metastasis, an elective lymph node dissection. Twenty-five SLNs were localised in the 14 patients examined. A 100% fusion correlation was achieved in all patients. The anatomical sites of SLNs detected during surgery showed 100% agreement with those localised on the multimodal fusion images. SLNs could be excised in 11/14 patients, six of whom had nodal metastasis. Our novel approach of multimodal fusion imaging for targeted SLN management in primary tumours with lymphatic drainage to anatomically difficult regions enables SLN biopsy even in patients with lymphatic drainage to obscure regions. Currently, we are testing its validity in larger patient groups and other tumour entities.

  20. An automated sequential injection analysis system for the determination of trace endotoxin levels in water.

    PubMed

    Samanta, Gautam; Zhang, Shuming; Dasgupta, Purnendu

    2003-01-01

    A new automated instrument based on the Limulus amebocyte lysate (LAL)-chromogenic substrate kinetic assay for the determination of bacterial endotoxins is reported. A computer controlled syringe pump-multiport valve combination was used to aspirate the sample and other reagents into a holding coil. The syringe was always filled with air; liquid did not enter the syringe. The valve could address up to four individual radial paths, fully referenced optical fiber LED-based absorbance detectors that were housed collectively in a single, small (20 x 20 x 30 mm) metal block with a heater and temperature sensor, and maintained at 37 degrees C. Assay mixtures containing sample or standards were delivered to the individual detector cells for the simultaneous collection of the time based absorbance data. The automated system determined endotoxins with good accuracy and reproducibility in the range of 0.005-0.5 endotoxin units (EU)/mL (r2 > or = 0.99). Based on three times the standard deviation of the blank and the slope of the calibration curve, the lower limit of detection was < or = 0.003 EU/mL. The variability of the assay method is less than 5% (n = 10). Analysis time required for a 0.005 EU/mL standard was <100 min. Appropriately diluted tap water samples were simultaneously analyzed by the present system and a manually loaded commercial microplate reader based instrument; the data were statistically indistinguishable at the 95% confidence level.

  1. Continuous cell introduction and rapid dynamic lysis for high-throughput single-cell analysis on microfludic chips with hydrodynamic focusing.

    PubMed

    Xu, Chun-Xiu; Yin, Xue-Feng

    2011-02-04

    A chip-based microfluidic system for high-throughput single-cell analysis is described. The system was integrated with continuous introduction of individual cells, rapid dynamic lysis, capillary electrophoretic (CE) separation and laser induced fluorescence (LIF) detection. A cross microfluidic chip with one sheath-flow channel located on each side of the sampling channel was designed. The labeled cells were hydrodynamically focused by sheath-flow streams and sequentially introduced into the cross section of the microchip under hydrostatic pressure generated by adjusting liquid levels in the reservoirs. Combined with the electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 33ms at the entry of the separation channel by Triton X-100 added in the sheath-flow solution. The maximum rate for introducing individual cells into the separation channel was about 150cells/min. The introduction of sheath-flow streams also significantly reduced the concentration of phosphate-buffered saline (PBS) injected into the separation channel along with single cells, thus reducing Joule heating during electrophoretic separation. The performance of this microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single erythrocytes. A throughput of 38cells/min was obtained. The proposed method is simple and robust for high-throughput single-cell analysis, allowing for analysis of cell population with considerable size to generate results with statistical significance. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Simultaneous determination of potassium and total fluoride in toothpastes using a SIA system with two potentiometric detectors.

    PubMed

    Pérez-Olmos, R; Soto, J C; Zárate, N; Díez, I

    2008-05-12

    A sequential injection analysis (SIA) system has been developed for the first time to quantify potassium and total fluoride in toothpastes and gels used to prevent both dentinal hypersensitivity and dental caries. To enable this simultaneous determination, potentiometric detection, using a conventional fluoride electrode and a tubular potassium selective electrode, formed by a PVC membrane containing valinomycin as ionophore, was carried out. A manifold that uses a three-way solenoid valve was designed. The former under binary sampling conditions, provides reproducible mixing ratios of two solutions. This fact facilitates that the system automatically generates, on-line, the calibration curves required by the analytical procedure. The calibration ranged from 1.0 x 10(-4) to 1.0 x 10(-3) mol L(-1) for both potassium and total fluoride determinations. The R.S.D. (11 readings) resulted to be less than 1.5% for both determinations. Off-line studies related to the dissolution of the solid samples, the transformation of monofluorophosphate in fluoride, the elimination of organic matrix interference onto the plastic membrane of the potassium electrode, and the selection of the most adequate TISAB solution for fluoride determination, were also considered. A sampling rate of 18 samples h(-1) for both determinations was attained, their precisions and accuracies being statistically indistinguishable from those achieved by atomic emission spectroscopy (for potassium determination) and by a conventional batch potentiometry (for total fluoride determination) adopted as reference techniques.

  3. In-capillary probing of quantum dots and fluorescent protein self-assembly and displacement using Förster resonance energy transfer.

    PubMed

    Wang, Jianhao; Fan, Jie; Li, Jinchen; Liu, Li; Wang, Jianpeng; Jiang, Pengju; Liu, Xiaoqian; Qiu, Lin

    2017-02-01

    Herein, a Förster resonance energy transfer system was designed, which consisted of CdSe/ZnS quantum dots donor and mCherry fluorescent protein acceptor. The quantum dots and the mCherry proteins were conjugated to permit Förster resonance energy transfer. Capillary electrophoresis with fluorescence detection was used for the analyses for the described system. The quantum dots and mCherry were sequentially injected into the capillary, while the real-time fluorescence signal of donor and acceptor was simultaneously monitored by two channels with fixed wavelength detectors. An effective separation of complexes from free donor and acceptor was achieved. Results showed quantum dots and hexahistidine tagged mCherry had high affinity and the assembly was affected by His 6 -mCherry/quantum dot molar ratio. The kinetics of the self-assembly was calculated using the Hill equation. The microscopic dissociation constant values for out of- and in-capillary assays were 10.49 and 23.39 μM, respectively. The capillary electrophoresis with fluorescence detection that monitored ligands competition assay further delineated the different binding capacities of histidine containing peptide ligands for binding sites on quantum dots. This work demonstrated a novel approach for the improvement of Förster resonance energy transfer for higher efficiency, increased sensitivity, intuitionistic observation, and low sample requirements of the in-capillary probing system. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample.

    PubMed

    Supharoek, Sam-Ang; Ponhong, Kraingkrai; Siriangkhawut, Watsaka; Grudpan, Kate

    2018-04-01

    A simple, rapid and environmentally friendly sequential injection analysis system employing natural extract reagents was developed for the determination of acetic acid following an acid-base reaction in the presence of an indicator. Powdered lime and turmeric were utilized as the natural base and indicator, respectively. Mixing lime and turmeric produced an orange to reddish-brown color solution which absorbed the maximum wavelength at 455 nm, with absorbance decreasing with increasing acetic acid concentration. Influential parameters including lime and turmeric concentrations, reagent and sample aspirated volumes, mixing coil length and dispensing flow rate were investigated and optimized. A standard calibration graph was plotted for 0-5.0 mmol/L acetic acid with r 2  = 0.9925. Relative standard deviations (RSD) at 2.0 and 4.0 mmol/L acetic acid were less than 3% (n = 7), with limit of detection (LOD) and limit of quantification (LOQ) at 0.12 and 0.24 mmol/L, respectively. The method was successfully applied to assay acetic acid concentration in cooking vinegar samples. Results achieved were not significantly different from those obtained following a batchwise standard AOAC titration method. Copyright © 2017. Published by Elsevier B.V.

  5. Generation Dependent Ultrafast Charge Separation and Recombination in a Pyrene-Viologen Family of Dendrons.

    PubMed

    Gong, Zheng; Bao, Jianhua; Nagai, Keiji; Iyoda, Tomokazu; Kawauchi, Takehiro; Piotrowiak, Piotr

    2016-05-12

    The ability of a dendritic network to intercept electrons and extend the lifetime of a short-lived photoinduced charge separated (CS) state was investigated in a homologous family of methyl viologen (MV(2+)) dendrons spanning four generations, G0 through G3. The CS state in the parent pyrene-methylene-viologen G0 system with a single acceptor exhibits an extremely short lifetime of τ = 0.72 ps. The expansion of the viologen network introduces slower components to the recombination kinetics by allowing the injected electron to migrate further away from the donor. The long-lived fraction of the population increases monotonically in the order G3 > G2 > G1 > G0, while the respective recombination rates decrease. In the highest generation of the dendron ∼14% of the CS state population experiences a 10-fold or greater lifetime extension. Long range tunneling across multiple viologen units and sequential site-to-site hopping both contribute to the overall effect. The large excess energy deposited in the apical viologen upon charge separation and the presence of an extended network of low lying π-orbitals likely facilitate shuttling the electron further down the dendron.

  6. The detection of pleural effusion using a parametric EIT technique.

    PubMed

    Arad, M; Zlochiver, S; Davidson, T; Shoenfeld, Y; Adunsky, A; Abboud, S

    2009-04-01

    The bioimpedance technique provides a safe, low-cost and non-invasive alternative for routine monitoring of lung fluid levels in patients. In this study we have investigated the feasibility of bioimpedance measurements to monitor pleural effusion (PE) patients. The measurement system (eight-electrode thoracic belt, opposite sequential current injections, 3 mA, 20 kHz) employed a parametric reconstruction algorithm to assess the left and right lung resistivity values. Bioimpedance measurements were taken before and after the removal of pleural fluids, while the patient was sitting at rest during tidal respiration in order to minimize movements of the thoracic cavity. The mean resistivity difference between the lung on the side with PE and the lung on the other side was -48 Omega cm. A high correlation was found between the mean lung resistivity value before the removal of the fluids and the volume of pleural fluids removed, with a sensitivity of -0.17 Omega cm ml(-1) (linear regression, R=0.53). The present study further supports the feasibility and applicability of the bioimpedance technique, and specifically the approach of parametric left and right lung resistivity reconstruction, in monitoring lung patients.

  7. Environmental Impact of Ionic Liquids: Automated Evaluation of the Chemical Oxygen Demand of Photochemically Degraded Compounds.

    PubMed

    Costa, Susana P F; Pereira, Sarah A P; Pinto, Paula C A G; Araujo, André R T S; Passos, Marieta L C; Saraiva, M Lúcia M F S

    2017-05-19

    A novel automated fluorimetric technique was developed for the assessment of the chemical oxygen demand (COD) of ionic liquids (ILs) and combined with a photodegradation step to promote IL degradation. The method was implemented on a sequential injection analysis (SIA) system and is based on the reduction of cerium(IV) in the presence of irradiated ILs. Compounds incorporating the chloride anion were found to exhibit higher COD values and 1-butyl-3-methylimidazolium chloride ([bmim] + [Cl] - ), 1-butyl-1-methylpyrrolidinium chloride ([bmpyr] + [Cl] - ), and1-hexyl-3-methylimidazolium chloride ([hmim] + [Cl] - ) also exhibited considerable photodegradability, whereas the cholinium cation and methanesulfonate and tetrafluoroborate anions showed resistance to photolysis. The developed methodology proved to be a simple, affordable, and robust method, showing good repeatability under the tested conditions (rsd <3.5 %, n=10). Therefore, it is expected that the developed approach can be used as a screening method for the preliminary evaluation of compounds' potential impact in the aquatic field. Additionally, the photolysis step presents an attractive option to promote degradation of ILs prior to their release into wastewater. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. An Interactive Microsoft(registered tm) Excel Program for Tracking a Single Evaporating Droplet in Crossflow

    NASA Technical Reports Server (NTRS)

    Liew, K. H.; Urip, E.; Yang, S. L.; Marek, C. J.

    2004-01-01

    Droplet interaction with a high temperature gaseous crossflow is important because of its wide application in systems involving two phase mixing such as in combustion requiring quick mixing of fuel and air with the reduction of pollutants and for jet mixing in the dilution zone of combustors. Therefore, the focus of this work is to investigate dispersion of a two-dimensional atomized and evaporating spray jet into a two-dimensional crossflow. An interactive Microsoft Excel program for tracking a single droplet in crossflow that has previously been developed will be modified to include droplet evaporation computation. In addition to the high velocity airflow, the injected droplets are also subjected to combustor temperature and pressure that affect their motion in the flow field. Six ordinary differential equations are then solved by 4th-order Runge-Kutta method using Microsoft Excel software. Microsoft Visual Basic programming and Microsoft Excel macrocode are used to produce the data and plot graphs describing the droplet's motion in the flow field. This program computes and plots the data sequentially without forcing the user to open other types of plotting programs. A user's manual on how to use the program is included.

  9. Mouse strain and injection site are crucial for detecting linked suppression in transplant recipients by trans-vivo DTH assay.

    PubMed

    Burlingham, W J; Jankowska-Gan, E

    2007-02-01

    Chemokine-driven accumulation of lymphocytes, mononuclear and polymorphonuclear proinflammatory cells in antigenic tissue sites is a key feature of several types of T-cell-dependent autoimmunity and transplant rejection pathology. It is now clear that the immune system expends considerable energy to control this process, exemplified by the sequential layers of regulatory cell input, both innate and adaptive, designed to prevent a classical Type IV or 'delayed-type' hypersensitivity (DTH) reaction from occurring in the visual field of the eye. Yet, despite an abundance of in vitro assays currently available to the human T-cell immunologist, none of them adequately models the human DTH response and its various control features. The theme of this article is that it is relatively easy to model the effector side of the human DTH response with xenogeneic adoptive transfer models. However, we show that in order to detect inhibition of a recall DTH in response to colocalized donor antigen (linked suppression)--a characteristic feature of peripheral tolerance to an organ transplant--both the challenge site and the immunocompetence of the mouse adoptive host are critical factors limiting the sensitivity of the trans-vivo DTH test.

  10. Ex vivo detection of macrophages in atherosclerotic plaques using intravascular ultrasonic-photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Quang Bui, Nhat; Hlaing, Kyu Kyu; Lee, Yong Wook; Kang, Hyun Wook; Oh, Junghwan

    2017-01-01

    Macrophages are excellent imaging targets for detecting atherosclerotic plaques as they are involved in all the developmental stages of atherosclerosis. However, no imaging technique is currently capable of visualizing macrophages inside blood vessel walls. The current study develops an intravascular ultrasonic-photoacoustic (IVUP) imaging system combined with indocyanine green (ICG) as a contrast agent to provide morphological and compositional information about the targeted samples. Both tissue-mimicking vessel phantoms and atherosclerotic plaque-mimicking porcine arterial tissues are used to demonstrate the feasibility of mapping macrophages labeled with ICG by endoscopically applying the proposed hybrid technique. A delay pulse triggering technique is able to sequentially acquire photoacoustic (PA) and ultrasound (US) signals from a single scan without using any external devices. The acquired PA and US signals are used to reconstruct 2D cross-sectional and 3D volumetric images of the entire tissue with the ICG-loaded macrophages injected. Due to high imaging contrast and sensitivity, the IVUP imaging vividly reveals structural information and detects the spatial distribution of the ICG-labeled macrophages inside the samples. ICG-assisted IVUP imaging can be a feasible imaging modality for the endoscopic detection of atherosclerotic plaques.

  11. Renewable Surface Fluorescence Sandwich Immunoassay Biosensor for Rapid Sensitive Botulinum Toxin Detection in an Automated Fluidic Format

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grate, Jay W.; Warner, Marvin G.; Ozanich, Richard M.

    2009-03-05

    A renewable surface biosensor for rapid detection of botulinum toxin is described based on fluidic automation of a fluorescence sandwich immunoassay, using a recombinant fragment of the toxin heavy chain as a structurally valid simulant. Monoclonal antibodies AR4 and RAZ1 bind to separate epitopes of both this fragment and the holotoxin. The AR4 antibody was covalently bound to Sepharose beads and used as the capture antibody. A rotating rod flow cell was used to capture these beads delivered as a suspension by the sequential injection flow system, creating a 3.6 microliter column. After perfusing the bead column with sample andmore » washing away the matrix, the column was perfused with Alexa 647 dye-labeled RAZ1 antibody as the reporter. Optical fibers coupled to the rotating rod flow cell at a 90 degree angle to one another delivered excitation light from a HeNe laser and collected fluorescent emission light for detection. After each measurement, the used sepharose beads are released and replaced with fresh beads. In a rapid screening approach to sample analysis, the toxin simulant was detected to concentrations of 10 pM in less than 20 minutes.« less

  12. Effective Control of Computationally Simulated Wing Rock in Subsonic Flow

    NASA Technical Reports Server (NTRS)

    Kandil, Osama A.; Menzies, Margaret A.

    1997-01-01

    The unsteady compressible, full Navier-Stokes (NS) equations and the Euler equations of rigid-body dynamics are sequentially solved to simulate the delta wing rock phenomenon. The NS equations are solved time accurately, using the implicit, upwind, Roe flux-difference splitting, finite-volume scheme. The rigid-body dynamics equations are solved using a four-stage Runge-Kutta scheme. Once the wing reaches the limit-cycle response, an active control model using a mass injection system is applied from the wing surface to suppress the limit-cycle oscillation. The active control model is based on state feedback and the control law is established using pole placement techniques. The control law is based on the feedback of two states: the roll-angle and roll velocity. The primary model of the computational applications consists of a 80 deg swept, sharp edged, delta wing at 30 deg angle of attack in a freestream of Mach number 0.1 and Reynolds number of 0.4 x 10(exp 6). With a limit-cycle roll amplitude of 41.1 deg, the control model is applied, and the results show that within one and one half cycles of oscillation, the wing roll amplitude and velocity are brought to zero.

  13. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters.

    PubMed

    Santos, Inês C; Mesquita, Raquel B R; Rangel, António O S S

    2015-09-03

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60-160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11-21 for the metal ions. A LOD of 0.23 μg L(-1) for cadmium, 2.39 μg L(-1) for zinc, and 0.11 μg L(-1) for copper and a sampling rate of 12, 13, and 15 h(-1) for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Diesel Fuel Systems. Teacher Edition (Revised).

    ERIC Educational Resources Information Center

    Clark, Elton; Huston, Jane, Ed.

    This module is one of a series of teaching guides that cover diesel mechanics. The module contains six instructional units that cover the following topics: (1) introduction to fuel injection systems and components; (2) injection nozzles; (3) distributor type injection pumps; (4) unit injectors; (5) in-line injection pumps; and (6) pressure timed…

  15. On the effect of injection timing on the ignition of lean PRF/air/EGR mixtures under direct dual fuel stratification conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luong, Minh Bau; Sankaran, Ramanan; Yu, Gwang Hyeon

    2017-06-09

    The ignition characteristics of lean primary reference fuel (PRF)/air/exhaust gas recirculation (EGR) mixture under reactivity-controlled compression ignition (RCCI) and direct duel fuel stratification (DDFS) conditions are investigated in this paper by 2-D direct numerical simulations (DNSs) with a 116-species reduced chemistry of the PRF oxidation. The 2-D DNSs of the DDFS combustion are performed by varying the injection timing of iso-octane (i-C 8H 18) with a pseudo-iso-octane (PC 8H 18) model together with a novel compression heating model to account for the compression heating and expansion cooling effects of the piston motion in an engine cylinder. The PC 8H 18more » model is newly developed to mimic the timing, duration, and cooling effects of the direct injection of i-C 8H 18 onto a premixed background charge of PRF/air/EGR mixture with composition inhomogeneities. It is found that the RCCI combustion exhibits a very high peak heat release rate (HRR) with a short combustion duration due to the predominance of the spontaneous ignition mode of combustion. However, the DDFS combustion has much lower peak HRR and longer combustion duration regardless of the fuel injection timing compared to those of the RCCI combustion, which is primarily attributed to the sequential injection of i-C 8H 18. It is also found that the ignition delay of the DDFS combustion features a non-monotonic behavior with increasing fuel-injection timing due to the different effect of fuel evaporation on the low-, intermediate-, and high-temperature chemistry of the PRF oxidation. The budget and Damköhler number analyses verify that although a mixed combustion mode of deflagration and spontaneous ignition exists during the early phase of the DDFS combustion, the spontaneous ignition becomes predominant during the main combustion, and hence, the spread-out of heat release rate in the DDFS combustion is mainly governed by the direct injection process of i-C 8H 18. Finally, a misfire is observed for the DDFS combustion when the direct injection of i-C 8H 18 occurs during the intermediate-temperature chemistry (ITC) regime between the first- and second-stage ignition. Finally, this is because the temperature drop induced by the direct injection of i-C 8H 18 impedes the main ITC reactions, and hence, the main combustion fails to occur.« less

  16. 40 CFR 49.143 - Construction and operational control measures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...: (i) An operating system designed to recover and inject all the produced natural gas into a natural... closed-vent system to: (i) An operating system designed to recover and inject the natural gas emissions... that pipeline injection of all or part of the natural gas collected in an operating system designed to...

  17. 40 CFR 49.143 - Construction and operational control measures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...: (i) An operating system designed to recover and inject all the produced natural gas into a natural... closed-vent system to: (i) An operating system designed to recover and inject the natural gas emissions... that pipeline injection of all or part of the natural gas collected in an operating system designed to...

  18. Wide-field piecemeal cold snare polypectomy of large sessile serrated polyps without a submucosal injection is safe.

    PubMed

    Tate, David J; Awadie, Halim; Bahin, Farzan F; Desomer, Lobke; Lee, Ralph; Heitman, Steven J; Goodrick, Kathleen; Bourke, Michael J

    2018-03-01

    BACKGROUND AND STUDY AIMS : Large series suggest endoscopic mucosal resection is safe and effective for the removal of large (≥ 10 mm) sessile serrated polyps (SSPs), but it exposes the patient to the risks of electrocautery, including delayed bleeding. We examined the feasibility and safety of piecemeal cold snare polypectomy (pCSP) for the resection of large SSPs.  Sequential large SSPs (10 - 35 mm) without endoscopic evidence of dysplasia referred over 12 months to a tertiary endoscopy center were considered for pCSP. A thin-wire snare was used in all cases. Submucosal injection was not performed. High definition imaging of the defect margin was used to ensure the absence of residual serrated tissue. Adverse events were assessed at 2 weeks and surveillance was planned for between 6 and 12 months.  41 SSPs were completely removed by pCSP in 34 patients. The median SSP size was 15 mm (interquartile range [IQR] 14.5 - 20 mm; range 10 - 35 mm). The median procedure duration was 4.5 minutes (IQR 1.4 - 6.3 minutes). There was no evidence of perforation or significant intraprocedural bleeding. At 2-week follow-up, there were no significant adverse events, including delayed bleeding and post polypectomy syndrome. First follow-up has been undertaken for 15 /41 lesions at a median of 6 months with no evidence of recurrence.  There is potential for pCSP to become the standard of care for non-dysplastic large SSPs. This could reduce the burden of removing SSPs on patients and healthcare systems, particularly by avoidance of delayed bleeding. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Capillary trapping quantification in sandstones using NMR relaxometry

    NASA Astrophysics Data System (ADS)

    Connolly, Paul R. J.; Vogt, Sarah J.; Iglauer, Stefan; May, Eric F.; Johns, Michael L.

    2017-09-01

    Capillary trapping of a non-wetting phase arising from two-phase immiscible flow in sedimentary rocks is critical to many geoscience scenarios, including oil and gas recovery, aquifer recharge and, with increasing interest, carbon sequestration. Here we demonstrate the successful use of low field 1H Nuclear Magnetic Resonance [NMR] to quantify capillary trapping; specifically we use transverse relaxation time [T2] time measurements to measure both residual water [wetting phase] content and the surface-to-volume ratio distribution (which is proportional to pore size] of the void space occupied by this residual water. Critically we systematically confirm this relationship between T2 and pore size by quantifying inter-pore magnetic field gradients due to magnetic susceptibility contrast, and demonstrate that our measurements at all water saturations are unaffected. Diffusion in such field gradients can potentially severely distort the T2-pore size relationship, rendering it unusable. Measurements are performed for nitrogen injection into a range of water-saturated sandstone plugs at reservoir conditions. Consistent with a water-wet system, water was preferentially displaced from larger pores while relatively little change was observed in the water occupying smaller pore spaces. The impact of cyclic wetting/non-wetting fluid injection was explored and indicated that such a regime increased non-wetting trapping efficiency by the sequential occupation of the most available larger pores by nitrogen. Finally the replacement of nitrogen by CO2 was considered; this revealed that dissolution of paramagnetic minerals from the sandstone caused by its exposure to carbonic acid reduced the in situ bulk fluid T2 relaxation time on a timescale comparable to our core flooding experiments. The implications of this for the T2-pore size relationship are discussed.

  20. Evaluation of the acute and chronic safety of the biosense injection catheter system in porcine hearts.

    PubMed

    Kornowski, R; Fuchs, S; Tio, F O; Pierre, A; Epstein, S E; Leon, M B

    1999-12-01

    Direct myocardial injection of therapeutic agents has been explored as a new method for myocardial revascularization. The integration of a 3D electromechanical mapping catheter with a retractable injection needle should allow for intramyocardial injection to identified sites, obviating the need for open heart surgery. This study assessed the procedural safety and performance characteristics of a novel guided catheter-based transendocardial injection system. The electromagnetic guidance system was coupled with a retrievable 27G needle for left ventricular endocardial injection. Using this system, we injected, transendocardially, methylene-blue (MB) dye tracer at a volume of 0.1 or 0.2 ml per injection in eight normal pigs. Animals were sacrificed acutely, at 1, 3, and 7 days (two animal in each time). Three animals served as controls. The injections were followed by coronary angiography and echocardiogram to assess possible ventricular or coronary perforation and wall motion abnormalities. CK-MB levels were measured up to 24 hr following the procedure. The animals were sacrificed at the assigned time for gross and histopathology evaluation. A total of 101 injections were made in all regions of the heart except the apex and the mitral valve. No animal died as a result of the mapping or injection procedures. Vital signs did not change relative to baseline after the mapping and injection procedures. CK-MB values did not increase over time and there was no evidence of sustained arrhythmia or hemodynamic compromise. There was no evidence of left ventricular or coronary perforation, global or regional wall motion abnormalities, or hemopericardium. On histologic evaluation, the estimated volume of tissue staining was greater than the volume of the injected MB dye due to dispersion of the injectate in the interstitial and intracellular fluid compartments. It is concluded that using this magnetic guidance catheter-based navigational system, it is feasible and safe to perform the transendocardial injection procedure. Thus, if it is determined that direct intramyocardial injection of drugs is a valid therapeutic strategy, this approach offers a clear advantage over surgically based transepicardial injection procedures. Cathet. Cardiovasc. Intervent. 48:447-453, 1999. Copyright 1999 Wiley-Liss, Inc.

Top