In-situ sequential laser transfer and laser reduction of graphene oxide films
NASA Astrophysics Data System (ADS)
Papazoglou, S.; Petridis, C.; Kymakis, E.; Kennou, S.; Raptis, Y. S.; Chatzandroulis, S.; Zergioti, I.
2018-04-01
Achieving high quality transfer of graphene on selected substrates is a priority in device fabrication, especially where drop-on-demand applications are involved. In this work, we report an in-situ, fast, simple, and one step process that resulted in the reduction, transfer, and fabrication of reduced graphene oxide-based humidity sensors, using picosecond laser pulses. By tuning the laser illumination parameters, we managed to implement the sequential printing and reduction of graphene oxide flakes. The overall process lasted only a few seconds compared to a few hours that our group has previously published. DC current measurements, X-Ray Photoelectron Spectroscopy, X-Ray Diffraction, and Raman Spectroscopy were employed in order to assess the efficiency of our approach. To demonstrate the applicability and the potential of the technique, laser printed reduced graphene oxide humidity sensors with a limit of detection of 1700 ppm are presented. The results demonstrated in this work provide a selective, rapid, and low-cost approach for sequential transfer and photochemical reduction of graphene oxide micro-patterns onto various substrates for flexible electronics and sensor applications.
Near-IR Image-Guided Laser Ablation of Demineralization on Tooth Occlusal Surfaces
Tom, Henry; Chan, Kenneth H.; Darling, Cynthia L.; Fried, Daniel
2016-01-01
Introduction Studies have shown that reflectance images at near-IR wavelengths coincident with higher water absorption are well-suited for image-guided laser ablation of carious lesions since the contrast between sound and demineralized enamel is extremely high and interference from stains is minimized. The objective of this study was to demonstrate that near-IR reflectance images taken at a wavelength range of 1,500–1,700 nm can be used to guide a 9.3 μm CO2 laser for the selective ablation of early demineralization on tooth occlusal surfaces. Methods The occlusal surfaces of ten sound human molars were used in this in vitro study. Shallow simulated caries lesions with random patterns and varying depth and position were produced on tooth occlusal surfaces. Sequential near-IR reflectance images at 1,500–1,700 nm were used to guide the laser for the selective removal of the demineralized enamel. Digital microscopy and polarization sensitive optical coherence tomography (PS-OCT) were used to assess selectivity. Results Images taken before and after lesion removal suggest that the demineralized areas were removed with high selectivity. Although the estimated volume of tissue ablated was typically higher than the initial lesion volume measured with PS-OCT, the volume of enamel removed by the laser correlated well with the initial lesion volume. Conclusion Sequential near-IR reflectance images at 1,500–1,700 nm can be used to guide a 9.3 μm CO2 laser for the selective ablation of early demineralization on tooth occlusal surfaces. PMID:26763111
Sequential and selective localized optical heating in water via on-chip dielectric nanopatterning.
Morsy, Ahmed M; Biswas, Roshni; Povinelli, Michelle L
2017-07-24
We study the use of nanopatterned silicon membranes to obtain optically-induced heating in water. We show that by varying the detuning between an absorptive optical resonance of the patterned membrane and an illumination laser, both the magnitude and response time of the temperature rise can be controlled. This allows for either sequential or selective heating of different patterned areas on chip. We obtain a steady-state temperature of approximately 100 °C for a 805.5nm CW laser power density of 66 µW/μm 2 and observe microbubble formation. The ability to spatially and temporally control temperature on the microscale should enable the study of heat-induced effects in a variety of chemical and biological lab-on-chip applications.
Dual-wavelength quantum cascade laser for trace gas spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jágerská, J.; Tuzson, B.; Mangold, M.
2014-10-20
We demonstrate a sequentially operating dual-wavelength quantum cascade laser with electrically separated laser sections, emitting single-mode at 5.25 and 6.25 μm. Based on a single waveguide ridge, this laser represents a considerable asset to optical sensing and trace gas spectroscopy, as it allows probing multiple gas species with spectrally distant absorption features using conventional optical setups without any beam combining optics. The laser capability was demonstrated in simultaneous NO and NO{sub 2} detection, reaching sub-ppb detection limits and selectivity comparable to conventional high-end spectroscopic systems.
Li, Guang; Sun, Jianfang; Shao, Xuebao; Sang, Honggui; Zhou, Zhanchao
2011-10-01
After laser irradiation, hemoglobin can transform into methemoglobin and coagulum, which have high absorptivity of near-infrared light. Sequential irradiation with 595 nm and 1,064 nm may be more effective than single wavelength to decrease residual vessel number in rooster combs. Six protocols (single pulse with 595 nm, double pulse with 595 nm, single pulse with 1,064 nm, double pulse with 1,064 nm, sequential irradiation with 595 nm and 1,064 nm (multiplex), and a blank control group) were used to compare the effects of sequential and single-wavelength irradiation on reducing residual vessel number, as well as the epidermal side effects, in the rooster comb. Different treatment techniques were applied to the same comb, at the same time. The treated areas of the epidermis and the residual vessels were observed using an optical microscope. All five techniques were effective in decreasing the number of residual vessels in the comb, and the side effects on the epidermis were similar for all. Considering the selectivity of the 595-nm laser and the rich melanin in the human epidermis, the dual-wavelength laser has a distinct advantage in treating vascular lesions. The authors have indicated no significant interest with commercial supporters. © 2011 by the American Society for Dermatologic Surgery, Inc.
Feature selection and back-projection algorithms for nonline-of-sight laser-gated viewing
NASA Astrophysics Data System (ADS)
Laurenzis, Martin; Velten, Andreas
2014-11-01
We discuss new approaches to analyze laser-gated viewing data for nonline-of-sight vision with a frame-to-frame back-projection as well as feature selection algorithms. Although first back-projection approaches use time transients for each pixel, our method has the ability to calculate the projection of imaging data on the voxel space for each frame. Further, different data analysis algorithms and their sequential application were studied with the aim of identifying and selecting signals from different target positions. A slight modification of commonly used filters leads to a powerful selection of local maximum values. It is demonstrated that the choice of the filter has an impact on the selectivity i.e., multiple target detection as well as on the localization precision.
Selective removal of demineralized enamel using a CO2 laser coupled with near-IR reflectance imaging
NASA Astrophysics Data System (ADS)
Tom, Henry; Chan, Kenneth H.; Saltiel, Daniel; Fried, Daniel
2015-02-01
Detection and diagnosis of early dental caries lesions can be difficult due to variable tooth coloration, staining of the teeth and poor contrast between sound and demineralized enamel. These problems can be overcome by using near-infrared (NIR) imaging. Previous studies have demonstrated that lasers can be integrated with NIR imaging devices, allowing image-guided ablation. The aim of this study was to demonstrate that NIR light at 1500 - 1700 nm can be used to guide a 9.3-μm CO2 laser for the selective ablation of early demineralization on tooth occlusal surfaces. The occlusal surfaces of ten sound human molars were used in this in-vitro study. Shallow simulated caries lesions of varying depth and position were produced on tooth occlusal surfaces using a demineralization solution. Sequential NIR reflectance images at 1500 - 1700 nm were used to guide the laser for selective ablation of the lesion areas. Digital microscopy and polarization sensitive optical coherence tomography (PS-OCT) were used to assess the selectivity of removal. This study demonstrates that high contrast NIR reflectance images can be used for the image-guided laser ablation of early demineralization from tooth occlusal surfaces.
Nilforoushzadeh, Mohammad Ali; Naieni, Farahnaz Fatemi; Siadat, Amir Hossein; Rad, Leila
2011-11-01
Laser systems that are commonly used for the treatment of hirsutism include the ruby laser (694 nm), the diode laser (800 nm), the alexandrite laser (755 nm) and the Nd:YAG laser (1084 nm). The diode laser and alexandrite laser are considered effective in treatment of hirsutism in dark-skinned patients. The response of hairs to these laser systems is variable and not complete. In this study, we compared the efficacy of these two laser systems for permanent hair removal. This was a randomized, controlled clinical trial that was performed with women of the age range 15-45 years old. After obtaining informed consent, the samples were randomized into two groups using random allocation software. The first group was treated with alexandrite laser alone (four sessions, two months apart). The second group was treated sequentially with diode laser for the first two sessions and alexandrite laser for the next two sessions. Overall, 111 patients (57 patients in the alexandrite laser group and 54 patients in the sequential diode-alexandrite laser group) were evaluated. There was no significant difference regarding mean of hair reduction between the two groups during the courses of treatment. Except for the first session, there was no significant difference regarding percent of patient satisfaction between the two groups (P value >0.05). Comparison between the two groups showed no significant difference one month, three months and six months after the last treatment (P value >0.05). Regarding the results of our study, there is no significant difference between sequential treatment with diode and alexandrite lasers versus alexandrite laser alone in the treatment of hirsutism. We suggest that in further studies, the efficacy of sequential treatment with other laser systems is evaluated against single treatment methods.
Early, James W.; Lester, Charles S.
2002-01-01
Optical fiber switches operated by electrical activation of at least one laser light modulator through which laser light is directed into at least one polarizer are used for the sequential transport of laser light from a single laser into a plurality of optical fibers. In one embodiment of the invention, laser light from a single excitation laser is sequentially transported to a plurality of optical fibers which in turn transport the laser light to separate individual remotely located laser fuel ignitors. The invention can be operated electro-optically with no need for any mechanical or moving parts, or, alternatively, can be operated electro-mechanically. The invention can be used to switch either pulsed or continuous wave laser light.
Ji, Seok Young; Choi, Wonsuk; Jeon, Jin-Woo; Chang, Won Seok
2018-01-01
The development of printing technologies has enabled the realization of electric circuit fabrication on a flexible substrate. However, the current technique remains restricted to single-layer patterning. In this paper, we demonstrate a fully solution-processable patterning approach for multi-layer circuits using a combined method of laser sintering and ablation. Selective laser sintering of silver (Ag) nanoparticle-based ink is applied to make conductive patterns on a heat-sensitive substrate and insulating layer. The laser beam path and irradiation fluence are controlled to create circuit patterns for flexible electronics. Microvia drilling using femtosecond laser through the polyvinylphenol-film insulating layer by laser ablation, as well as sequential coating of Ag ink and laser sintering, achieves an interlayer interconnection between multi-layer circuits. The dimension of microvia is determined by a sophisticated adjustment of the laser focal position and intensity. Based on these methods, a flexible electronic circuit with chip-size-package light-emitting diodes was successfully fabricated and demonstrated to have functional operations. PMID:29425144
Native Frames: Disentangling Sequential from Concerted Three-Body Fragmentation
NASA Astrophysics Data System (ADS)
Rajput, Jyoti; Severt, T.; Berry, Ben; Jochim, Bethany; Feizollah, Peyman; Kaderiya, Balram; Zohrabi, M.; Ablikim, U.; Ziaee, Farzaneh; Raju P., Kanaka; Rolles, D.; Rudenko, A.; Carnes, K. D.; Esry, B. D.; Ben-Itzhak, I.
2018-03-01
A key question concerning the three-body fragmentation of polyatomic molecules is the distinction of sequential and concerted mechanisms, i.e., the stepwise or simultaneous cleavage of bonds. Using laser-driven fragmentation of OCS into O++C++S+ and employing coincidence momentum imaging, we demonstrate a novel method that enables the clear separation of sequential and concerted breakup. The separation is accomplished by analyzing the three-body fragmentation in the native frame associated with each step and taking advantage of the rotation of the intermediate molecular fragment, CO2 + or CS2 + , before its unimolecular dissociation. This native-frame method works for any projectile (electrons, ions, or photons), provides details on each step of the sequential breakup, and enables the retrieval of the relevant spectra for sequential and concerted breakup separately. Specifically, this allows the determination of the branching ratio of all these processes in OCS3 + breakup. Moreover, we find that the first step of sequential breakup is tightly aligned along the laser polarization and identify the likely electronic states of the intermediate dication that undergo unimolecular dissociation in the second step. Finally, the separated concerted breakup spectra show clearly that the central carbon atom is preferentially ejected perpendicular to the laser field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
El-Khoury, Patrick Z.; Ueltschi, Tyler W.; Mifflin, Amanda L.
Non-resonant tip-enhanced Raman images of 4,4'-dimercaptostilbene on silver reveal that different vibrational resonances of the reporter are selectively enhanced at different sites on the metal substrate. Sequentially recorded images track molecular diffusion within the diffraction-limited laser spot which illuminates the substrate. In effect, the recorded time resolved (Δt = 10 s) pixelated images (25 nm x 8 cm-1) broadcast molecule-local field interactions which take place on much finer scales.
Sugeno-Fuzzy Expert System Modeling for Quality Prediction of Non-Contact Machining Process
NASA Astrophysics Data System (ADS)
Sivaraos; Khalim, A. Z.; Salleh, M. S.; Sivakumar, D.; Kadirgama, K.
2018-03-01
Modeling can be categorised into four main domains: prediction, optimisation, estimation and calibration. In this paper, the Takagi-Sugeno-Kang (TSK) fuzzy logic method is examined as a prediction modelling method to investigate the taper quality of laser lathing, which seeks to replace traditional lathe machines with 3D laser lathing in order to achieve the desired cylindrical shape of stock materials. Three design parameters were selected: feed rate, cutting speed and depth of cut. A total of twenty-four experiments were conducted with eight sequential runs and replicated three times. The results were found to be 99% of accuracy rate of the TSK fuzzy predictive model, which suggests that the model is a suitable and practical method for non-linear laser lathing process.
Marini, Leonardo
2009-12-01
Many different lasers, polychromatic high-intensity light sources (PCLs), and RF devices have claimed clinical efficacy in rejuvenating the skin. In this study, the sequential combination of two different laser wavelengths was evaluated to produce reliably significant clinical improvements optimizing treatment parameters. The left volar aspects of the forearms of four volunteers were treated with nine different parameter settings using a variable pulsewidth fractional Er:YAG 2940-nm laser with and without air cooling. The pain perception level was recorded on a 0-10 point scale (0=No pain; 10=Most severe pain). Three evaluations were made: during treatment, immediately after treatment, and 5 minutes after treatment. The same investigation was made on the right volar aspects of the same four volunteers using a short-pulse, random pattern, 3-mm spot, scanner-assisted Nd-YAG 1064-nm laser at 0.3 ms pulsewidth at seven different parameter settings. Clinical evaluations were made concerning erythema and edema 3 days after treatment, as well as pre-operative and 60 days postoperative skin texture plus color uniformity. Considering that the majority of cosmetic patients are willing to accept a relatively short and uneventful downtime (2-4 days according to a study we are presently conducting) and do prefer to limit their intra- and postoperative pain to a minimum, the best combination of clinical improvement matching these two important parameters were selected for our study. A treatment strategy combining two sequential passes of long-pulse Nd:YAG laser (Nd:YAG-LP) at 0.3 and 35 ms followed by two passes of long-pulse fractional Er:YAG laser (Er:YAG-FT) at 600 micros was designed to treat the facial regions of 10 volunteers affected by a combination of intrinsic (chrono-) and extrinsic (mostly photo-) aging. The pain perception level was recorded on a 0-10 scale (0=No pain; 10=Most severe pain). Three evaluations were made: during, immediately after, and 5 minutes after treatment. Erythema and edema were evaluated on a 0-3 point scale (0=No clinical signs; 3=Severe Clinical signs) at 7, 15 and 30 days. Improvements were determined by blind evaluation of photographs before, at 4 weeks, and at 8 weeks following treatments. Patient satisfaction was also evaluated on a 0-4 point scale (0=No satisfaction; 4=Excellent perceived improvement, 76-100%). At the 30-day follow-up, participants had clinically detectable improvements of facial telangiectasias (1-25%), lentigines (25-50%), diffuse dyspigmentation (25-75%), fine lines (25-75%), and skin texture (25-75%). Clinical improvements were maintained at the 60-day follow-up, demonstrating the prolonged photothermally induced biological effect on skin function and texture. All volunteers confirmed their willingness to undergo the same procedure again to maintain and possibly improve their clinical results. Further clinical evaluations at 4 and 6 months will therefore be needed to identify a suitably convenient interval between two consecutive procedures. The present study demonstrates objective and subjective improvements in fine lines, skin texture and dyspigmentation of facial skin after one sequential non-ablative and ablative laser treatment combining two different laser sources (Nd:YAG laser + Er:YAG laser).
Frequency Resolved Nanoscale Chemical Imaging of 4,4'-Dimercaptostilbene on Silver
El-Khoury, Patrick Z.; Ueltschi, Tyler W.; Mifflin, Amanda L.; ...
2014-11-26
Non-resonant tip-enhanced Raman images of 4,4'-dimercaptostilbene on silver reveal that different vibrational resonances of the reporter are selectively enhanced at different sites on the metal substrate. Sequentially recorded images track molecular diffusion within the diffraction-limited laser spot which illuminates the substrate. In effect, the recorded time resolved (Δt = 10 s) pixelated images (25 nm x 8 cm-1) broadcast molecule-local field interactions which take place on much finer scales.
The Geoscience Laser Altimeter System (GLAS) Laser Transmitter
NASA Technical Reports Server (NTRS)
Afzal, Robert S.; Yu, Anthony W.; Dallas, Joseph L.; Melak, Anthony; Lukemir, Alan; Ramos-Izqueirdo, L.; Mamakos, William
2007-01-01
The Geoscience Laser Altimeter System (GLAS), launched in January 2003, is a laser altimeter and lidar for the Earth Observing System's (EOS) ICESat mission. GLAS accommodates three, sequentially operated, diode-pumped, solid-state, Nd:YAG laser transmitters. The laser transmitter requirements, design and qualification test results for this space-based remote sensing instrument is summarized and presented
NASA Astrophysics Data System (ADS)
Song, Xingliang; Sha, Pengfei; Fan, Yuanyuan; Jiang, R.; Zhao, Jiangshan; Zhou, Yi; Yang, Junhong; Xiong, Guangliang; Wang, Yu
2018-02-01
Due to complex kinetics of formation and loss mechanisms, such as ion-ion recombination reaction, neutral species harpoon reaction, excited state quenching and photon absorption, as well as their interactions, the performance behavior of different laser gas medium parameters for excimer laser varies greatly. Therefore, the effects of gas composition and total gas pressure on excimer laser performance attract continual research studies. In this work, orthogonal experimental design (OED) is used to investigate quantitative and qualitative correlations between output laser energy characteristics and gas medium parameters for an ArF excimer laser with plano-plano optical resonator operation. Optimized output laser energy with good pulse to pulse stability can be obtained effectively by proper selection of the gas medium parameters, which makes the most of the ArF excimer laser device. Simple and efficient method for gas medium optimization is proposed and demonstrated experimentally, which provides a global and systematic solution. By detailed statistical analysis, the significance sequence of relevant parameter factors and the optimized composition for gas medium parameters are obtained. Compared with conventional route of varying single gas parameter factor sequentially, this paper presents a more comprehensive way of considering multivariables simultaneously, which seems promising in striking an appropriate balance among various complicated parameters for power scaling study of an excimer laser.
Challenges in Laser Sintering of Melt-Processable Thermoset Imide Resin
NASA Technical Reports Server (NTRS)
Chuang, Kathy C.; Gornet, Timothy; Koerner, Hilmar
2016-01-01
Polymer Laser Sintering (LS) is an additive manufacturing technique that builds 3D models layer by layer using a laser to selectively melt cross sections in powdered polymeric materials, following sequential slices of the CAD model. LS generally uses thermoplastic polymeric powders, such as polyamides (i.e. Nylon), and the resultant 3D objects are often weaker in their strength compared to traditionally processed materials, due to the lack of polymer inter-chain connection in the z-direction. The objective of this project is to investigate the possibility of printing a melt-processable RTM370 imide resin powder terminated with reactive phenylethynyl groups by LS, followed by a postcure in order to promote additional crosslinking to achieve higher temperature (250-300 C) capability. A preliminary study to build tensile specimens by LS and the corresponding DSC and rheology study of RTM370 during LS process is presented.
Challenges in Laser Sintering of Thermoset Imide Resin
NASA Technical Reports Server (NTRS)
Chuang, Kathy C.; Gornet, Timothy; Koerner, Hilmar
2016-01-01
Polymer Laser Sintering (LS) is an additive manufacturing technique that builds 3D models layer by layer using a laser to selectively melt cross sections in powdered polymeric materials, following sequential slices of the CAD model. LS generally uses thermoplastic polymeric powders, such as polyamides (i.e. Nylon), and the resultant 3D objects are often weaker in their strength compared to traditionally processed materials, due to the lack of polymer inter-chain connection in the z-direction. The objective of this project is to investigate the possibility of printing a melt-processable RTM370 imide resin powder terminated with reactive phenylethynyl groups by LS, followed by a postcure in order to promote additional crosslinking to achieve higher temperature (250-300 C) capability. A preliminary study to build tensile specimens by LS and the corresponding DSC and rheology study of RTM370 during LS process is presented.
Biomedical applications of laser photoionization
NASA Astrophysics Data System (ADS)
Xiong, Xiaoxiong; Moore, Larry J.; Fassett, John R.; O'Haver, Thomas C.
1991-07-01
Trace elements are important for many essential metabolic functions. Zinc is a structural/functional component in more than 200 enzymes active in the biochemistry of cell division and tissue growth, neurology and endocrine control. Calcium is involved in intracellular control mechanisms and in skeletal bone building and resorption processes related to osteoporosis. Sensitive and selective laser photoionization is being developed to understand mechanisms in smaller samples and biological units approaching the cellular domain. Zinc has an ionization potential of 9.4 eV, or 75766.8 cm-1. Several processes are being explored, including two-photon resonant, three- photon ionization utilizing sequential UV transitions, e.g., 4s2 1S0 yields 4s4p 3P1 and 4s4p 3P1 yields 4s5d 3D1. Preliminary zinc stable isotope ratio data obtained by thermal atomization and laser photoionization agree with accepted values within 2 to 5%, except for anomalous 67Zn. Photoionization of calcium is being studied for isotope enrichment and ratio measurement using narrow and medium bandwidth lasers. Several ionization pathways, e.g., 4s2 1S0 - 2hv1 yields 4s10s - hv2 yields Ca+ (4s2S), are being investigated for isotopically selective ionization. Auto-ionization pathways are explored for greater efficiency in isotopic analysis. All studies have utilized a Nd:YAG- pumped laser system with one or two frequency-doubled tunable dye lasers coupled either to a magnetic sector or time-of-flight mass spectrometer.
Salah El Din, Manal Mohamed; Samy, Nevien Ahmed; Salem, Amira Eid
2017-06-01
Both pulsed dye laser and combined 585/1064-nm (sequential dual-wavelength PDL and Nd:YAG) laser improves inflammatory skin disorders including acne vulgaris. To compare the efficacy of 585-nm pulsed dye laser versus sequential dual-wavelength PDL and Nd:YAG in treatment of acne vulgaris. Thirty patients with acne vulgaris were treated by PDL alone on half of the face while contra lateral half was treated by combined 585/1064 nm laser. The study showed that inflammatory acne lesions count was significantly reduced by 82.5% (p 0.0001) on PDL sides and by 83.5% (p 0.00001) on combined 585/1064-nm side after 8 weeks, while reduction of non-inflammatory acne lesions was observed at 8 weeks by 58.4% and 71.5% respectively. However, difference between the two modalities was not statistically significant. PDL and combined PDL/Nd:YAG laser treatment were found to be an effective, safe and well-tolerated treatment option for inflammatory and non-inflammatory acne vulgaris.
Sequential, progressive, equal-power, reflective beam-splitter arrays
NASA Astrophysics Data System (ADS)
Manhart, Paul K.
2017-11-01
The equations to calculate equal-power reflectivity of a sequential series of beam splitters is presented. Non-sequential optical design examples are offered for uniform illumination using diode lasers. Objects created using Boolean operators and Swept Surfaces can create objects capable of reflecting light into predefined elevation and azimuth angles. Analysis of the illumination patterns for the array are also presented.
Sequential single shot X-ray photon correlation spectroscopy at the SACLA free electron laser
Lehmkühler, Felix; Kwaśniewski, Paweł; Roseker, Wojciech; ...
2015-11-27
In this study, hard X-ray free electron lasers allow for the first time to access dynamics of condensed matter samples ranging from femtoseconds to several hundred seconds. In particular, the exceptional large transverse coherence of the X-ray pulses and the high time-averaged flux promises to reach time and length scales that have not been accessible up to now with storage ring based sources. However, due to the fluctuations originating from the stochastic nature of the self-amplified spontaneous emission (SASE) process the application of well established techniques such as X-ray photon correlation spectroscopy (XPCS) is challenging. Here we demonstrate a single-shotmore » based sequential XPCS study on a colloidal suspension with a relaxation time comparable to the SACLA free-electron laser pulse repetition rate. High quality correlation functions could be extracted without any indications for sample damage. This opens the way for systematic sequential XPCS experiments at FEL sources.« less
Sequential single shot X-ray photon correlation spectroscopy at the SACLA free electron laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lehmkühler, Felix; Kwaśniewski, Paweł; Roseker, Wojciech
In this study, hard X-ray free electron lasers allow for the first time to access dynamics of condensed matter samples ranging from femtoseconds to several hundred seconds. In particular, the exceptional large transverse coherence of the X-ray pulses and the high time-averaged flux promises to reach time and length scales that have not been accessible up to now with storage ring based sources. However, due to the fluctuations originating from the stochastic nature of the self-amplified spontaneous emission (SASE) process the application of well established techniques such as X-ray photon correlation spectroscopy (XPCS) is challenging. Here we demonstrate a single-shotmore » based sequential XPCS study on a colloidal suspension with a relaxation time comparable to the SACLA free-electron laser pulse repetition rate. High quality correlation functions could be extracted without any indications for sample damage. This opens the way for systematic sequential XPCS experiments at FEL sources.« less
Inertial navigation sensor integrated obstacle detection system
NASA Technical Reports Server (NTRS)
Bhanu, Bir (Inventor); Roberts, Barry A. (Inventor)
1992-01-01
A system that incorporates inertial sensor information into optical flow computations to detect obstacles and to provide alternative navigational paths free from obstacles. The system is a maximally passive obstacle detection system that makes selective use of an active sensor. The active detection typically utilizes a laser. Passive sensor suite includes binocular stereo, motion stereo and variable fields-of-view. Optical flow computations involve extraction, derotation and matching of interest points from sequential frames of imagery, for range interpolation of the sensed scene, which in turn provides obstacle information for purposes of safe navigation.
Laser speckle technique for burner liner strain measurements
NASA Technical Reports Server (NTRS)
Stetson, K. A.
1982-01-01
Thermal and mechanical strains were measured on samples of a common material used in jet engine burner liners, which were heated from room temperature to 870 C and cooled back to 220 C, in a laboratory furnance. The physical geometry of the sample surface was recorded at selected temperatures by a set of 12 single exposure speckle-grams. Sequential pairs of specklegrams were compared in a heterodyne interferometer which give high precision measurement of differential displacements. Good speckle correlation between the first and last specklegrams is noted which allows a check on accumulate errors.
Paasch, Uwe; Sonja, Grunewald; Haedersdal, Merete
2014-06-01
Diode laser-based skin heating has been shown to minimise scars by interfering with wound healing responses through the induction of heat shock proteins (HSP). HSP are also induced after ablative fractional laser (AFXL) wound healing. AFXL itself is highly recommended for scar treatment. Therefore, the sequential combination of both modalities may produce superior outcomes. The aim of this study was to examine the pretreatment effects of a diode laser before AFXL on wound healing responses in terms of HSP up-regulation in an in vitro model. Immediate responses and responses on days 1, 3 or 6 post-procedure were studied in an in vitro porcine skin model (n = 240). Untreated samples served as control. Immunohistochemical investigation (Hsp70) was performed in all untreated controls, diode laser-, AFXL-, and in diode laser + AFXL-treated samples. Hsp70 was shown to be up-regulated by all interventions between days 1 and 6 after interventions. The largest effect was caused by the combination of a diode laser and an AFXL procedure. Diode laser exposure induces a skin HSP response that can be further enhanced by sequential AFXL treatment. Clinical studies are necessary to investigate the dose response of HSP on scar formation and refine suitable laser exposure settings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isselhardt, Brett H.
2011-09-01
Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure relative uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process to provide a distinction between uranium atoms and potential isobars without the aid of chemical purification and separation. We explore the laser parameters critical to the ionization process and their effects on the measured isotope ratio. Specifically, the use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of 235U/ 238U ratios to decrease laser-induced isotopic fractionation. By broadening the bandwidth of the first laser inmore » a 3-color, 3-photon ionization process from a bandwidth of 1.8 GHz to about 10 GHz, the variation in sequential relative isotope abundance measurements decreased from >10% to less than 0.5%. This procedure was demonstrated for the direct interrogation of uranium oxide targets with essentially no sample preparation. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variation in laser parameters on the measured isotope ratio. This work demonstrates that RIMS can be used for the robust measurement of uranium isotope ratios.« less
Lucinda, Tan Siyun; Hazel, Oon Hwee Boon; Joyce, Lee Siong Siong; Hon, Chua Sze
2013-01-01
Decorative tattooing has been linked with a range of complications, with pseudolymphoma being unusual and challenging to manage. We report a case of tattoo-induced pseudolymphoma, who failed treatment with potent topical and intralesional steroids. She responded well to sequential treatment with ablative fractional resurfacing (AFR) followed by Q-Switched (QS) Nd:YAG 532 nm laser. Interestingly, we managed to document the clearance of her tattoo pigments after laser treatments on histology and would like to highlight the use of special stains such as the Grocott's Methenamine Silver (GMS) stain as a useful method to assess the presence of tattoo pigment in cases where dense inflammatory infiltrates are present. PMID:24470721
High energy protons generation by two sequential laser pulses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xiaofeng; Shen, Baifei, E-mail: bfshen@mail.shcnc.ac.cn, E-mail: zhxm@siom.ac.cn; Zhang, Xiaomei, E-mail: bfshen@mail.shcnc.ac.cn, E-mail: zhxm@siom.ac.cn
2015-04-15
The sequential proton acceleration by two laser pulses of relativistic intensity is proposed to produce high energy protons. In the scheme, a relativistic super-Gaussian (SG) laser pulse followed by a Laguerre-Gaussian (LG) pulse irradiates dense plasma attached by underdense plasma. A proton beam is produced from the target and accelerated in the radiation pressure regime by the short SG pulse and then trapped and re-accelerated in a special bubble driven by the LG pulse in the underdense plasma. The advantages of radiation pressure acceleration and LG transverse structure are combined to achieve the effective trapping and acceleration of protons. Inmore » a two-dimensional particle-in-cell simulation, protons of 6.7 GeV are obtained from a 2 × 10{sup 22 }W/cm{sup 2} SG laser pulse and a LG pulse at a lower peak intensity.« less
An investigation of nonsimultaneous laser-induced fluorescence
NASA Technical Reports Server (NTRS)
Fletcher, D. G.
1993-01-01
An alternative to simultaneous, two-line laser-induced fluorescence for thermodynamic property measurement is presented. This spectroscopic approach is similar to multiple-overheat hot-wire anemometry and is based on laser excitation of different fluorescence transitions for separate, sequential wind tunnel runs. Both fluctuating and mean thermodynamic property measurements seem to be achievable with this method without exciting the transitions during the same laser pulse.
Herman, Krisztian; Szabó, László; Leopold, Loredana F; Chiş, Vasile; Leopold, Nicolae
2011-05-01
A new, simple, and effective approach for multianalyte sequential surface-enhanced Raman scattering (SERS) detection in a flow cell is reported. The silver substrate was prepared in situ by laser-induced photochemical synthesis. By focusing the laser on the 320 μm inner diameter glass capillary at 0.5 ml/min continuous flow of 1 mM silver nitrate and 10 mM sodium citrate mixture, a SERS active silver spot on the inner wall of the glass capillary was prepared in a few seconds. The test analytes, dacarbazine, 4-(2-pyridylazo)resorcinol (PAR) complex with Cu(II), and amoxicillin, were sequentially injected into the flow cell. Each analyte was adsorbed to the silver surface, enabling the recording of high intensity SERS spectra even at 2 s integration times, followed by desorption from the silver surface and being washed away from the capillary. Before and after each analyte passed the detection window, citrate background spectra were recorded, and thus, no "memory effects" perturbed the SERS detection. A good reproducibility of the SERS spectra obtained under flow conditions was observed. The laser-induced photochemically synthesized silver substrate enables high Raman enhancement, is characterized by fast preparation with a high success rate, and represents a valuable alternative for silver colloids as SERS substrate in flow approaches.
Laser-driven dielectric electron accelerator for radiobiology researches
NASA Astrophysics Data System (ADS)
Koyama, Kazuyoshi; Matsumura, Yosuke; Uesaka, Mitsuru; Yoshida, Mitsuhiro; Natsui, Takuya; Aimierding, Aimidula
2013-05-01
In order to estimate the health risk associated with a low dose radiation, the fundamental process of the radiation effects in a living cell must be understood. It is desired that an electron bunch or photon pulse precisely knock a cell nucleus and DNA. The required electron energy and electronic charge of the bunch are several tens keV to 1 MeV and 0.1 fC to 1 fC, respectively. The smaller beam size than micron is better for the precise observation. Since the laser-driven dielectric electron accelerator seems to suite for the compact micro-beam source, a phase-modulation-masked-type laser-driven dielectric accelerator was studied. Although the preliminary analysis made a conclusion that a grating period and an electron speed must satisfy the matching condition of LG/λ = v/c, a deformation of a wavefront in a pillar of the grating relaxed the matching condition and enabled the slow electron to be accelerated. The simulation results by using the free FDTD code, Meep, showed that the low energy electron of 20 keV felt the acceleration field strength of 20 MV/m and gradually felt higher field as the speed was increased. Finally the ultra relativistic electron felt the field strength of 600 MV/m. The Meep code also showed that a length of the accelerator to get energy of 1 MeV was 3.8 mm, the required laser power and energy were 11 GW and 350 mJ, respectively. Restrictions on the laser was eased by adopting sequential laser pulses. If the accelerator is illuminated by sequential N pulses, the pulse power, pulse width and the pulse energy are reduced to 1/N, 1/N and 1/N2, respectively. The required laser power per pulse is estimated to be 2.2 GW when ten pairs of sequential laser pulse is irradiated.
Laser patterning of highly conductive flexible circuits
NASA Astrophysics Data System (ADS)
Ji, Seok Young; Muhammed Ajmal, C.; Kim, Taehun; Chang, Won Seok; Baik, Seunghyun
2017-04-01
There has been considerable attention paid to highly conductive flexible adhesive (CFA) materials as electrodes and interconnectors for future flexible electronic devices. However, the patterning technology still needs to be developed to construct micro-scale electrodes and circuits. Here we developed the selective laser sintering technology where the pattering and curing were accomplished simultaneously without making additional masks. The CFA was composed of micro-scale Ag flakes, multiwalled carbon nanotubes decorated with Ag nanoparticles, and a nitrile-butadiene-rubber matrix. The Teflon-coated polyethylene terephthalate film was used as a flexible substrate. The width of lines (50-500 μm) and circuit patterns were controlled by the programmable scanning of a focused laser beam (power = 50 mW, scanning speed = 1 mm s-1). The laser irradiation removed solvent and induced effective coalescence among fillers providing a conductivity as high as 25 012 S cm-1. The conductivity stability was excellent under the ambient air and humid environments. The normalized resistance change of the pattern was smaller than 1.2 at the bending radius of 5 mm. The cyclability and adhesion of the laser-sintered line pattern on the substrate was excellent. A flexible circuit was fabricated sequentially for operating light emitting diodes during the bending motion, demonstrating excellent feasibility for practical applications in flexible electronics.
Laser patterning of highly conductive flexible circuits.
Ji, Seok Young; Ajmal, C Muhammed; Kim, Taehun; Chang, Won Seok; Baik, Seunghyun
2017-04-21
There has been considerable attention paid to highly conductive flexible adhesive (CFA) materials as electrodes and interconnectors for future flexible electronic devices. However, the patterning technology still needs to be developed to construct micro-scale electrodes and circuits. Here we developed the selective laser sintering technology where the pattering and curing were accomplished simultaneously without making additional masks. The CFA was composed of micro-scale Ag flakes, multiwalled carbon nanotubes decorated with Ag nanoparticles, and a nitrile-butadiene-rubber matrix. The Teflon-coated polyethylene terephthalate film was used as a flexible substrate. The width of lines (50-500 μm) and circuit patterns were controlled by the programmable scanning of a focused laser beam (power = 50 mW, scanning speed = 1 mm s -1 ). The laser irradiation removed solvent and induced effective coalescence among fillers providing a conductivity as high as 25 012 S cm -1 . The conductivity stability was excellent under the ambient air and humid environments. The normalized resistance change of the pattern was smaller than 1.2 at the bending radius of 5 mm. The cyclability and adhesion of the laser-sintered line pattern on the substrate was excellent. A flexible circuit was fabricated sequentially for operating light emitting diodes during the bending motion, demonstrating excellent feasibility for practical applications in flexible electronics.
Mamdani-Fuzzy Modeling Approach for Quality Prediction of Non-Linear Laser Lathing Process
NASA Astrophysics Data System (ADS)
Sivaraos; Khalim, A. Z.; Salleh, M. S.; Sivakumar, D.; Kadirgama, K.
2018-03-01
Lathing is a process to fashioning stock materials into desired cylindrical shapes which usually performed by traditional lathe machine. But, the recent rapid advancements in engineering materials and precision demand gives a great challenge to the traditional method. The main drawback of conventional lathe is its mechanical contact which brings to the undesirable tool wear, heat affected zone, finishing, and dimensional accuracy especially taper quality in machining of stock with high length to diameter ratio. Therefore, a novel approach has been devised to investigate in transforming a 2D flatbed CO2 laser cutting machine into 3D laser lathing capability as an alternative solution. Three significant design parameters were selected for this experiment, namely cutting speed, spinning speed, and depth of cut. Total of 24 experiments were performed with eight (8) sequential runs where they were then replicated three (3) times. The experimental results were then used to establish Mamdani - Fuzzy predictive model where it yields the accuracy of more than 95%. Thus, the proposed Mamdani - Fuzzy modelling approach is found very much suitable and practical for quality prediction of non-linear laser lathing process for cylindrical stocks of 10mm diameter.
Valero, Enrique; Adan, Antonio; Cerrada, Carlos
2012-01-01
This paper is focused on the automatic construction of 3D basic-semantic models of inhabited interiors using laser scanners with the help of RFID technologies. This is an innovative approach, in whose field scarce publications exist. The general strategy consists of carrying out a selective and sequential segmentation from the cloud of points by means of different algorithms which depend on the information that the RFID tags provide. The identification of basic elements of the scene, such as walls, floor, ceiling, windows, doors, tables, chairs and cabinets, and the positioning of their corresponding models can then be calculated. The fusion of both technologies thus allows a simplified 3D semantic indoor model to be obtained. This method has been tested in real scenes under difficult clutter and occlusion conditions, and has yielded promising results. PMID:22778609
Multiple laser pulse ignition method and apparatus
Early, James W.
1998-01-01
Two or more laser light pulses with certain differing temporal lengths and peak pulse powers can be employed sequentially to regulate the rate and duration of laser energy delivery to fuel mixtures, thereby improving fuel ignition performance over a wide range of fuel parameters such as fuel/oxidizer ratios, fuel droplet size, number density and velocity within a fuel aerosol, and initial fuel temperatures.
NASA Astrophysics Data System (ADS)
Wolfram, Markus; König, Stephan; Bandelow, Steffi; Fischer, Paul; Jankowski, Alexander; Marx, Gerrit; Schweikhard, Lutz
2018-02-01
Lead clusters {{{{Pb}}}{n}}+/- in the size range between about n = 15 and 40 have recently shown to exhibit complex dissociation spectra due to sequential and competing decays. In order to disentangle the pathways the exemplary {{{{Pb}}}31}+ clusters have been stored and size selected in a Penning trap and irradiated by nanosecond laser pulses. We present time-resolved measurements at time scales from several tens of microseconds to several hundreds of milliseconds. The study results in strong evidence that {{{{Pb}}}31}+ decays not only by neutral monomer evaporation but also by neutral heptamers breaking off. In addition, the decays are further followed to smaller products. The corresponding decay and growth times show that {{{{Pb}}}30}+ also dissociates by either monomer evaporation or heptamer break-off. Furthermore, the product {{{{Pb}}}17}+ may well be a result of heptamer break-off from {{{{Pb}}}24}+—as the second step of a sequential heptamer decay.
NASA Astrophysics Data System (ADS)
Zhang, Bin; Gan, Yi; Xu, Chang-Qing
2018-06-01
The field sequential modulation of a Nd:YVO4/MgO:PPLN intra-cavity, frequency doubling green laser was studied. The modulation frequency was set at 1 kHz and the duty cycle was changed from 20% to CW operation. It was shown that the quasi-phase matched (QPM) temperature decreases with an increase of the modulation duty cycle, and in turn causing the peak efficiency to rise. It was found that the temperature change in MgO:PPLN and the thermal lens effect in Nd:YVO4 crystal were the respective origins of these observed experimental phenomena.
Early, James W.; Lester, Charles S.
2003-01-01
In the apparatus of the invention, a first excitation laser or other excitation light source is used in tandem with an ignitor laser to provide a compact, durable, engine deployable fuel ignition laser system. Reliable fuel ignition is provided over a wide range of fuel conditions by using a single remote excitation light source for one or more small lasers located proximate to one or more fuel combustion zones. In a third embodiment, alternating short and long pulses of light from the excitation light source are directed into the ignitor laser. Each of the embodiments of the invention can be multiplexed so as to provide laser light energy sequentially to more than one ignitor laser.
Multiple laser pulse ignition method and apparatus
Early, J.W.
1998-05-26
Two or more laser light pulses with certain differing temporal lengths and peak pulse powers can be employed sequentially to regulate the rate and duration of laser energy delivery to fuel mixtures, thereby improving fuel ignition performance over a wide range of fuel parameters such as fuel/oxidizer ratios, fuel droplet size, number density and velocity within a fuel aerosol, and initial fuel temperatures. 18 figs.
Mjollnir Rotational Line Scan Diagnostics.
1981-05-19
using long cavity. M8 Removable Pellicle Beam Splitter for He-Ne Lineup Beam. Removed before HF or DF laser is turned on. 27 A 27 * A r of the chopper...three probe laser lines, however three lines were sequentially measured to verify the diagnostic equipment. Two of the three lines have been monitored
Moshirfar, Majid; Fenzl, Carlton R; Meyer, Jay J; Neuffer, Marcus C; Espandar, Ladan; Mifflin, Mark D
2011-02-01
To evaluate the safety, efficacy, and visual outcomes of simultaneous and sequential implantation of Intacs (Addition Technology, Inc, Sunnyvale, CA) and Verisyse phakic intraocular lens (AMO, Santa Ana, CA) in selected cases of ectatic corneal disease. John A. Moran Eye Center, University of Utah, UT. Prospective data were collected from 19 eyes of 12 patients (5 eyes, post-laser in situ keratomileusis ectasia and 14 eyes, keratoconus). Intacs segments were implanted followed by insertion of a phakic Verisyse lens at the same session (12 eyes) in the simultaneous group or several months later (7 eyes) in the sequential group. The uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and manifest refraction were recorded at each visit. No intraoperative or postoperative complications were observed. At the last follow-up (19 ± 6 months), in the simultaneous group, mean spherical error was -0.79 ± 1.0 diopter (D) (range, -2.0 to +1.50 D) and cylindrical error +2.06 ± 1.21 D (range, +0.5 to +3.75 D). In the sequential group, at the last follow-up, at 36 ± 21 months, the mean spherical error was -1.64 ± 1.31 D (range, -3.25 to +1.0 D) and cylindrical error +2.07 ± 1.03 D (range, +0.75 to +3.25 D). There were no significant differences in mean uncorrected visual acuity or BSCVA between the 2 groups preoperatively or postoperatively. No eye lost lines of preoperative BSCVA. Combined insertion of Intacs and Verisyse was safe and effective in all cases. The outcomes of the simultaneous implantation of the Intacs and Verisyse lens in 1 surgery were similar to the results achieved with sequential implantation using 2 surgeries.
Combination free electron and gaseous laser
Brau, Charles A.; Rockwood, Stephen D.; Stein, William E.
1980-01-01
A multiple laser having one or more gaseous laser stages and one or more free electron stages. Each of the free electron laser stages is sequentially pumped by a microwave linear accelerator. Subsequently, the electron beam is directed through a gaseous laser, in the preferred embodiment, and in an alternative embodiment, through a microwave accelerator to lower the energy level of the electron beam to pump one or more gaseous lasers. The combination laser provides high pulse repetition frequencies, on the order of 1 kHz or greater, high power capability, high efficiency, and tunability in the synchronous production of multiple beams of coherent optical radiation.
National Ignition Facility main laser stray light analysis and control
DOE Office of Scientific and Technical Information (OSTI.GOV)
English, R E; Miller, J L; Peterson, G
1998-06-26
Stray light analysis has been carried out for the main laser section of the National Ignition Facility main laser section using a comprehensive non-sequential ray trace model supplemented with additional ray trace and diffraction propagation modeling. This paper describes the analysis and control methodology, gives examples of ghost paths and required tilted lenses, baffles, absorbers, and beam dumps, and discusses analysis of stray light "pencil beams" in the system.
Multiple ionization of neon by soft x-rays at ultrahigh intensity
NASA Astrophysics Data System (ADS)
Guichard, R.; Richter, M.; Rost, J.-M.; Saalmann, U.; Sorokin, A. A.; Tiedtke, K.
2013-08-01
At the free-electron laser FLASH, multiple ionization of neon atoms was quantitatively investigated at photon energies of 93.0 and 90.5 eV. For ion charge states up to 6+, we compare the respective absolute photoionization yields with results from a minimal model and an elaborate description including standard sequential and direct photoionization channels. Both approaches are based on rate equations and take into account a Gaussian spatial intensity distribution of the laser beam. From the comparison we conclude that photoionization up to a charge of 5+ can be described by the minimal model which we interpret as sequential photoionization assisted by electron shake-up processes. For higher charges, the experimental ionization yields systematically exceed the elaborate rate-based prediction.
Hennes, M; Schuler, V; Weng, X; Buchwald, J; Demaille, D; Zheng, Y; Vidal, F
2018-04-26
We employ kinetic Monte-Carlo simulations to study the growth process of metal-oxide nanocomposites obtained via sequential pulsed laser deposition. Using Ni-SrTiO3 (Ni-STO) as a model system, we reduce the complexity of the computational problem by choosing a coarse-grained approach mapping Sr, Ti and O atoms onto a single effective STO pseudo-atom species. With this ansatz, we scrutinize the kinetics of the sequential synthesis process, governed by alternating deposition and relaxation steps, and analyze the self-organization propensity of Ni atoms into straight vertically aligned nanowires embedded in the surrounding STO matrix. We finally compare the predictions of our binary toy model with experiments and demonstrate that our computational approach captures fundamental aspects of self-assembled nanowire synthesis. Despite its simplicity, our modeling strategy successfully describes the impact of relevant parameters like the concentration or laser frequency on the final nanoarchitecture of metal-oxide thin films grown via pulsed laser deposition.
Comparison Between NIST and AF Laser Energy Standards Using High Power Lasers
Li, Xiaoyu; Scott (Retired), Thomas; Cromer, Chris; Cooper, David; Comisford, Steven
2007-01-01
We report the results of a high-energy laser calorimeter comparison conducted by the National Institute of Standards and Technology (NIST), Boulder, Colorado and the U.S. Air Force Primary Standards laboratory (AFPSL), Heath, Ohio. A laser power meter, used as a transfer standard, was calibrated at each laboratory, sequentially, and the measurement results were compared. These measurements were performed at a nominal power of 800 W and a wavelength of 10.6 μm using CO2 lasers. Excellent measurement agreement (1.02 %) was demonstrated, which was well within each of the expanded uncertainties from the two laboratories involved in this comparison. PMID:27110471
Paintable band-edge liquid crystal lasers.
Gardiner, Damian J; Morris, Stephen M; Hands, Philip J W; Mowatt, Carrie; Rutledge, Rupert; Wilkinson, Timothy D; Coles, Harry J
2011-01-31
In this paper we demonstrate photonic band-edge laser emission from emulsion-based polymer dispersed liquid crystals. The lasing medium consists of dye-doped chiral nematic droplets dispersed within a polymer matrix that spontaneously align as the film dries. Such lasers can be easily formed on single substrates with no alignment layers. The system combines the self-organizing periodic structure of chiral nematic liquid crystals with the simplicity of the emulsion procedure so as to produce a material that retains the emission characteristics of band-edge lasers yet can be readily coated. Sequential and stacked layers demonstrate the possibility of achieving simultaneous multi-wavelength laser output from glass, metallic, and flexible substrates.
Pump-probe imaging of laser-induced periodic surface structures after ultrafast irradiation of Si
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, Ryan D.; Torralva, Ben; Adams, David P.
2013-09-30
Ultrafast pump-probe microscopy has been used to investigate laser-induced periodic surface structure (LIPSS) formation on polished Si surfaces. A crater forms on the surface after irradiation by a 150 fs laser pulse, and a second, subsequent pulse forms LIPSS within the crater. Sequentially delayed images show that LIPSS with a periodicity slightly less than the fundamental laser wavelength of 780 nm appear on Si surfaces ∼50 ps after arrival of the second pump laser pulse, well after the onset of melting. LIPSS are observed on the same timescale as material removal, suggesting that their formation involves material ejection.
Automatic registration of ICG images using mutual information and perfusion analysis
NASA Astrophysics Data System (ADS)
Kim, Namkug; Seo, Jong-Mo; Lee, June-goo; Kim, Jong Hyo; Park, Kwangsuk; Yu, Hyeong-Gon; Yu, Young Suk; Chung, Hum
2005-04-01
Introduction: Indocyanin green fundus angiographic images (ICGA) of the eyes is useful method in detecting and characterizing the choroidal neovascularization (CNV), which is the major cause of the blindness over 65 years of age. To investigate the quantitative analysis of the blood flow on ICGA, systematic approach for automatic registration of using mutual information and a quantitative analysis was developed. Methods: Intermittent sequential images of indocyanin green angiography were acquired by Heidelberg retinal angiography that uses the laser scanning system for the image acquisition. Misalignment of the each image generated by the minute eye movement of the patients was corrected by the mutual information method because the distribution of the contrast media on image is changing throughout the time sequences. Several region of interest (ROI) were selected by a physician and the intensities of the selected region were plotted according to the time sequences. Results: The registration of ICGA time sequential images is required not only translate transform but also rotational transform. Signal intensities showed variation based on gamma-variate function depending on ROIs and capillary vessels show more variance of signal intensity than major vessels. CNV showed intermediate variance of signal intensity and prolonged transit time. Conclusion: The resulting registered images can be used not only for quantitative analysis, but also for perfusion analysis. Various investigative approached on CNV using this method will be helpful in the characterization of the lesion and follow-up.
Hackel, Richard P.
1992-01-01
A laser amplifier chain has a plurality of laser amplifiers arranged in a chain to sequentially amplify a low-power signal beam to produce a significantly higher-power output beam. Overall efficiency of such a chain is improved if high-gain, low efficiency amplifiers are placed on the upstream side of the chain where only a very small fraction of the total pumped power is received by the chain and low-gain, high-efficiency amplifiers are placed on the downstream side where a majority of pumping energy is received by the chain.
NASA Technical Reports Server (NTRS)
Sarrafzadeh-Khoee, Adel K. (Inventor)
2000-01-01
The invention provides a method of triple-beam and triple-sensor in a laser speckle strain/deformation measurement system. The triple-beam/triple-camera configuration combined with sequential timing of laser beam shutters is capable of providing indications of surface strain and structure deformations. The strain and deformation quantities, the four variables of surface strain, in-plane displacement, out-of-plane displacement and tilt, are determined in closed form solutions.
Sequential lift and suture technique for post-LASIK corneal striae.
Mackool, Richard J; Monsanto, Vivian R
2003-04-01
We describe a surgical technique to manage persistent corneal striae after laser in situ keratomileusis (LASIK). The sequential lift and suture technique reduces the time required for LASIK, eliminates the need to fixate the flap with forceps during suturing, and increases the accuracy of suture placement. The results in 10 eyes (9 patients) showed complete resolution of striae with improvement in subjective symptoms (glare and blurred vision) and best corrected visual acuity.
NASA Astrophysics Data System (ADS)
Grum-Grzhimailo, A. N.; Gryzlova, E. V.; Kuzmina, E. I.; Chetverkina, A. S.; Strakhova, S. I.
2015-04-01
Two nonlinear atomic photoprocesses are theoretically considered with the emphasis on the photoelectron angular distributions and their modifications due to violation of the dipole approximation: sequential two-photon double ionization and two-color above threshold ionization. These reactions are now accessible with X-ray free electron lasers. Both processes are exemplified by the ionization of krypton: from the 4p shell in the sequential two-photon double ionization and from the 2s shell in the two-color above-threshold ionization, which are compared to the Ar(3p) and Ne(1s) ionization, respectively. Noticeable nondipole effects are predicted.
Marques, Manuel J; Bradu, Adrian; Podoleanu, Adrian Gh
2014-05-01
We report a Talbot bands-based optical coherence tomography (OCT) system capable of producing longitudinal B-scan OCT images and en-face scanning laser ophthalmoscopy (SLO) images of the human retina in-vivo. The OCT channel employs a broadband optical source and a spectrometer. A gap is created between the sample and reference beams while on their way towards the spectrometer's dispersive element to create Talbot bands. The spatial separation of the two beams facilitates collection by an SLO channel of optical power originating exclusively from the retina, deprived from any contribution from the reference beam. Three different modes of operation are presented, constrained by the minimum integration time of the camera used in the spectrometer and by the galvo-scanners' scanning rate: (i) a simultaneous acquisition mode over the two channels, useful for small size imaging, that conserves the pixel-to-pixel correspondence between them; (ii) a hybrid sequential mode, where the system switches itself between the two regimes and (iii) a sequential "on-demand" mode, where the system can be used in either OCT or SLO regimes for as long as required. The two sequential modes present varying degrees of trade-off between pixel-to-pixel correspondence and independent full control of parameters within each channel. Images of the optic nerve and fovea regions obtained in the simultaneous (i) and in the hybrid sequential mode (ii) are presented.
Marques, Manuel J.; Bradu, Adrian; Podoleanu, Adrian Gh.
2014-01-01
We report a Talbot bands-based optical coherence tomography (OCT) system capable of producing longitudinal B-scan OCT images and en-face scanning laser ophthalmoscopy (SLO) images of the human retina in-vivo. The OCT channel employs a broadband optical source and a spectrometer. A gap is created between the sample and reference beams while on their way towards the spectrometer’s dispersive element to create Talbot bands. The spatial separation of the two beams facilitates collection by an SLO channel of optical power originating exclusively from the retina, deprived from any contribution from the reference beam. Three different modes of operation are presented, constrained by the minimum integration time of the camera used in the spectrometer and by the galvo-scanners’ scanning rate: (i) a simultaneous acquisition mode over the two channels, useful for small size imaging, that conserves the pixel-to-pixel correspondence between them; (ii) a hybrid sequential mode, where the system switches itself between the two regimes and (iii) a sequential “on-demand” mode, where the system can be used in either OCT or SLO regimes for as long as required. The two sequential modes present varying degrees of trade-off between pixel-to-pixel correspondence and independent full control of parameters within each channel. Images of the optic nerve and fovea regions obtained in the simultaneous (i) and in the hybrid sequential mode (ii) are presented. PMID:24877006
NASA Astrophysics Data System (ADS)
Tsibidis, George D.; Mimidis, Alexandros; Skoulas, Evangelos; Kirner, Sabrina V.; Krüger, Jörg; Bonse, Jörn; Stratakis, Emmanuel
2018-01-01
We investigate the periodic structure formation upon intense femtosecond pulsed irradiation of chrome steel (100Cr6) for linearly polarised laser beams. The underlying physical mechanism of the laser-induced periodic structures is explored, their spatial frequency is calculated and theoretical results are compared with experimental observations. The proposed theoretical model comprises estimations of electron excitation, heat transfer, relaxation processes, and hydrodynamics-related mass transport. Simulations describe the sequential formation of sub-wavelength ripples and supra-wavelength grooves. In addition, the influence of the laser wavelength on the periodicity of the structures is discussed. The proposed theoretical investigation offers a systematic methodology towards laser processing of steel surfaces with important applications.
Delay test generation for synchronous sequential circuits
NASA Astrophysics Data System (ADS)
Devadas, Srinivas
1989-05-01
We address the problem of generating tests for delay faults in non-scan synchronous sequential circuits. Delay test generation for sequential circuits is a considerably more difficult problem than delay testing of combinational circuits and has received much less attention. In this paper, we present a method for generating test sequences to detect delay faults in sequential circuits using the stuck-at fault sequential test generator STALLION. The method is complete in that it will generate a delay test sequence for a targeted fault given sufficient CPU time, if such a sequence exists. We term faults for which no delay test sequence exists, under out test methodology, sequentially delay redundant. We describe means of eliminating sequential delay redundancies in logic circuits. We present a partial-scan methodology for enhancing the testability of difficult-to-test of untestable sequential circuits, wherein a small number of flip-flops are selected and made controllable/observable. The selection process guarantees the elimination of all sequential delay redundancies. We show that an intimate relationship exists between state assignment and delay testability of a sequential machine. We describe a state assignment algorithm for the synthesis of sequential machines with maximal delay fault testability. Preliminary experimental results using the test generation, partial-scan and synthesis algorithm are presented.
Kunimoto, Yasuomi; Hasegawa, Kensaku; Arii, Shiro; Kataoka, Hideyuki; Yazama, Hiroaki; Kuya, Junko; Kitano, Hiroya
2014-04-01
Numerous studies have reported sound-induced motion of the tympanic membrane (TM). To demonstrate sequential motion characteristics of the entire TM by noncontact laser Doppler vibrometry (LDV), we have investigated multipoint TM measurement. A laser Doppler vibrometer was mounted on a surgical microscope. The velocity was measured at 33 points on the TM using noncontact LDV without any reflectors. Measurements were performed with tonal stimuli of 1, 3, and 6 kHz. Amplitudes were calculated from these measurements, and time-dependent changes in TM motion were described using a graphics application. TM motions were detected more clearly and stably at 1 and 3 kHz than at other frequencies. This is because the external auditory canal acted as a resonant tube near 3 kHz. TM motion displayed 1 peak at 1 kHz and 2 peaks at 3 kHz. Large amplitudes were detected in the posterosuperior quadrant (PSQ) at 1 kHz and in the PSQ and anteroinferior quadrant (AIQ) at 3 kHz. The entire TM showed synchronized movement centered on the PSQ at 1 kHz, with phase-shifting between PSQ and AIQ movement at 3 kHz. Amplitude was smaller at the umbo than at other parts. In contrast, amplitudes at high frequencies were too small and complicated to detect any obvious peaks. Sequential multipoint motion of the tympanic membrane showed that vibration characteristics of the TM differ according to the part and frequency.
Hackel, R.P.
1992-10-20
A laser amplifier chain has a plurality of laser amplifiers arranged in a chain to sequentially amplify a low-power signal beam to produce a significantly higher-power output beam. Overall efficiency of such a chain is improved if high-gain, low efficiency amplifiers are placed on the upstream side of the chain where only a very small fraction of the total pumped power is received by the chain and low-gain, high-efficiency amplifiers are placed on the downstream side where a majority of pumping energy is received by the chain. 6 figs.
Practical method and device for enhancing pulse contrast ratio for lasers and electron accelerators
Zhang, Shukui; Wilson, Guy
2014-09-23
An apparatus and method for enhancing pulse contrast ratios for drive lasers and electron accelerators. The invention comprises a mechanical dual-shutter system wherein the shutters are placed sequentially in series in a laser beam path. Each shutter of the dual shutter system has an individually operated trigger for opening and closing the shutter. As the triggers are operated individually, the delay between opening and closing first shutter and opening and closing the second shutter is variable providing for variable differential time windows and enhancement of pulse contrast ratio.
Wissel, Tobias; Stüber, Patrick; Wagner, Benjamin; Bruder, Ralf; Schweikard, Achim; Ernst, Floris
2016-04-01
Patient immobilization and X-ray-based imaging provide neither a convenient nor a very accurate way to ensure low repositioning errors or to compensate for motion in cranial radiotherapy. We therefore propose an optical tracking device that exploits subcutaneous structures as landmarks in addition to merely spatial registration. To develop such head tracking algorithms, precise and robust computation of these structures is necessary. Here, we show that the tissue thickness can be predicted with high accuracy and moreover exploit local neighborhood information within the laser spot grid on the forehead to further increase this estimation accuracy. We use statistical learning with Support Vector Regression and Gaussian Processes to learn a relationship between optical backscatter features and an MR tissue thickness ground truth. We compare different kernel functions for the data of five different subjects. The incident angle of the laser on the forehead as well as local neighborhoods is incorporated into the feature space. The latter represent the backscatter features from four neighboring laser spots. We confirm that the incident angle has a positive effect on the estimation error of the tissue thickness. The root-mean-square error falls even below 0.15 mm when adding the complete neighborhood information. This prior knowledge also leads to a smoothing effect on the reconstructed skin patch. Learning between different head poses yields similar results. The partial overlap of the point clouds makes the trade-off between novel information and increased feature space dimension obvious and hence feature selection by e.g., sequential forward selection necessary.
Korolkov, M V; Manz, J
2007-05-07
The preparation of matrix isolated homonuclear diatomic molecules in a vibrational superposition state c0Phie=1,v=0+cjPhie=1,v=j, with large (|c0|2 approximately 1) plus small contributions (|cj|2<1) of the ground v=0 and specific v=j low excited vibrational eigenstates, respectively, in the electronic ground (e=1) state, and without any net population transfer to electronic excited (e>1) states, is an important challenge; it serves as a prerequisite for coherent spin control. For this purpose, the authors investigate two scenarios of laser pulse control, involving sequential or intrapulse pump- and dump-type transitions via excited vibronic states Phiex,k with a dominant singlet or triplet character. The mechanisms are demonstrated by means of quantum simulations for representative nuclear wave packets on coupled potential energy surfaces, using as an example a one-dimensional model for Cl2 in an Ar matrix. A simple three-state model (including Phi1,0, Phi1,j and Phiex,k) allows illuminating analyses and efficient determinations of the parameters of the laser pulses based on the values of the transition energies and dipole couplings of the transient state which are derived from the absorption spectra.
Toytman, I; Silbergleit, A; Simanovski, D; Palanker, D
2010-10-01
Transparent biological tissues can be precisely dissected with ultrafast lasers using optical breakdown in the tight focal zone. Typically, tissues are cut by sequential application of pulses, each of which produces a single cavitation bubble. We investigate the hydrodynamic interactions between simultaneous cavitation bubbles originating from multiple laser foci. Simultaneous expansion and collapse of cavitation bubbles can enhance the cutting efficiency, by increasing the resulting deformations in tissue, and the associated rupture zone. An analytical model of the flow induced by the bubbles is presented and experimentally verified. The threshold strain of the material rupture is measured in a model tissue. Using the computational model and the experimental value of the threshold strain one can compute the shape of the rupture zone in tissue resulting from application of multiple bubbles. With the threshold strain of 0.7 two simultaneous bubbles produce a continuous cut when applied at the distance 1.35 times greater than that required in sequential approach. Simultaneous focusing of the laser in multiple spots along the line of intended cut can extend this ratio to 1.7. Counterpropagating jets forming during collapse of two bubbles in materials with low viscosity can further extend the cutting zone-up to approximately a factor of 1.5.
Note: Laser beam scanning using a ferroelectric liquid crystal spatial light modulator
NASA Astrophysics Data System (ADS)
Das, Abhijit; Boruah, Bosanta R.
2014-04-01
In this work we describe laser beam scanning using a ferroelectric liquid crystal spatial light modulator. Commercially available ferroelectric liquid crystal spatial light modulators are capable of displaying 85 colored images in 1 s using a time dithering technique. Each colored image, in fact, comprises 24 single bit (black and white) images displayed sequentially. We have used each single bit image to write a binary phase hologram. For a collimated laser beam incident on the hologram, one of the diffracted beams can be made to travel along a user defined direction. We have constructed a beam scanner employing the above arrangement and demonstrated its use to scan a single laser beam in a laser scanning optical sectioning microscope setup.
Yang, Xiupei; Su, Yan; Paau, Man Chin; Choi, Martin M F
2012-02-07
This paper presents a simple and convenient methodology to separate and characterize water-soluble gold nanocluster stabilized with penicillamine ligands (AuNC-SR) in aqueous medium by sequential size-selective precipitation (SSSP) and mass spectrometry (MS). The highly polydisperse crude AuNC-SR product with an average core diameter of 2.1 nm was initially synthesized by a one-phase solution method. AuNCs were then precipitated and separated successively from larger to smaller ones by progressively increasing the concentration of acetone in the aqueous AuNCs solution. The SSSP fractions were analyzed by UV-vis spectroscopy, matrix-assisted laser desorption/ionization time-of-flight-MS, and thermogravimetric analysis (TGA). The MS and TGA data confirmed that the fractions precipitated from 36, 54, 72, and 90% v/v acetone (F(36%), F(54%), F(72%), and F(90%)) comprised families of close core size AuNCs with average molecular formulas of Au(38)(SR)(18), Au(28)(SR)(15), Au(18)(SR)(12), and Au(11)(SR)(8), respectively. In addition, F(36%), F(54%), F(72%), and F(90%) contained also the typical magic-sized gold nanoparticles of Au(38), Au(25), Au(18), and Au(11), respectively, together with some other AuNCs. This study shed light on the potential use of SSSP for simple and large-scale preliminary separation of polydisperse water-soluble AuNCs into different fractions with a relatively narrower size distribution. © 2012 American Chemical Society
Method of selective reduction of halodisilanes with alkyltin hydrides
D'Errico, John J.; Sharp, Kenneth G.
1989-01-01
The invention relates to the selective and sequential reduction of halodisilanes by reacting these compounds at room temperature or below with trialkyltin hydrides or dialkyltin dihydrides without the use of free radical intermediates. The alkyltin hydrides selectively and sequentially reduce the Si-Cl, Si-Br or Si-I bonds while leaving intact the Si-Si and Si-F bonds present.
Real-Time Detection and Tracking of Multiple People in Laser Scan Frames
NASA Astrophysics Data System (ADS)
Cui, J.; Song, X.; Zhao, H.; Zha, H.; Shibasaki, R.
This chapter presents an approach to detect and track multiple people ro bustly in real time using laser scan frames. The detection and tracking of people in real time is a problem that arises in a variety of different contexts. Examples in clude intelligent surveillance for security purposes, scene analysis for service robot, and crowd behavior analysis for human behavior study. Over the last several years, an increasing number of laser-based people-tracking systems have been developed in both mobile robotics platforms and fixed platforms using one or multiple laser scanners. It has been proved that processing on laser scanner data makes the tracker much faster and more robust than a vision-only based one in complex situations. In this chapter, we present a novel robust tracker to detect and track multiple people in a crowded and open area in real time. First, raw data are obtained that measures two legs for each people at a height of 16 cm from horizontal ground with multiple registered laser scanners. A stable feature is extracted using accumulated distribu tion of successive laser frames. In this way, the noise that generates split and merged measurements is smoothed well, and the pattern of rhythmic swinging legs is uti lized to extract each leg. Second, a probabilistic tracking model is presented, and then a sequential inference process using a Bayesian rule is described. A sequential inference process is difficult to compute analytically, so two strategies are presented to simplify the computation. In the case of independent tracking, the Kalman fil ter is used with a more efficient measurement likelihood model based on a region coherency property. Finally, to deal with trajectory fragments we present a concise approach to fuse just a little visual information from synchronized video camera to laser data. Evaluation with real data shows that the proposed method is robust and effective. It achieves a significant improvement compared with existing laser-based trackers.
Liu, Sonia Y; Chrystal, Peter V; Cowieson, Aaron J; Truong, Ha H; Moss, Amy F; Selle, Peter H
2017-01-01
A total of 360 male Ross 308 broiler chickens were used in a feeding study to assess the influence of macronutrients and energy density on feed intakes from 10 to 31 days post-hatch. The study comprised ten dietary treatments from five dietary combinations and two feeding approaches: sequential and choice feeding. The study included eight experimental diets and each dietary combination was made from three experimental diets. Choice fed birds selected between three diets in separate feed trays at the same time; whereas the three diets were offered to sequentially fed birds on an alternate basis during the experimental period. There were no differences between starch and protein intakes between choice and sequentially fed birds (P > 0.05) when broiler chickens selected between diets with different starch, protein and lipid concentrations. When broiler chickens selected between diets with different starch and protein but similar lipid concentrations, both sequentially and choice fed birds selected similar ratios of starch and protein intake (P > 0.05). However, when broiler chickens selected from diets with different protein and lipid but similar starch concentrations, choice fed birds had higher lipid intake (129 versus 118 g/bird, P = 0.027) and selected diets with lower protein concentrations (258 versus 281 g/kg, P = 0.042) than birds offered sequential diet options. Choice fed birds had greater intakes of the high energy diet (1471 g/bird, P < 0.0001) than low energy (197 g/bird) or medium energy diets (663 g/bird) whilst broiler chickens were offered diets with different energy densities but high crude protein (300 g/kg) or digestible lysine (17.5 g/kg) concentrations. Choice fed birds had lower FCR (1.217 versus 1.327 g/g, P < 0.0001) and higher carcass yield (88.1 versus 87.3%, P = 0.012) than sequentially fed birds. This suggests that the dietary balance between protein and energy is essential for optimal feed conversion efficiency. The intake path of macronutrients from 10-31 days in choice and sequential feeding groups were plotted and compared with the null path if broiler chickens selected equal amounts of the three diets in the combination. Regardless of feeding regimen, the intake paths of starch and protein are very close to the null path; however, lipid and protein intake paths in choice fed birds are father from the null path than sequentially fed birds.
Chrystal, Peter V.; Cowieson, Aaron J.; Truong, Ha H.; Moss, Amy F.; Selle, Peter H.
2017-01-01
A total of 360 male Ross 308 broiler chickens were used in a feeding study to assess the influence of macronutrients and energy density on feed intakes from 10 to 31 days post-hatch. The study comprised ten dietary treatments from five dietary combinations and two feeding approaches: sequential and choice feeding. The study included eight experimental diets and each dietary combination was made from three experimental diets. Choice fed birds selected between three diets in separate feed trays at the same time; whereas the three diets were offered to sequentially fed birds on an alternate basis during the experimental period. There were no differences between starch and protein intakes between choice and sequentially fed birds (P > 0.05) when broiler chickens selected between diets with different starch, protein and lipid concentrations. When broiler chickens selected between diets with different starch and protein but similar lipid concentrations, both sequentially and choice fed birds selected similar ratios of starch and protein intake (P > 0.05). However, when broiler chickens selected from diets with different protein and lipid but similar starch concentrations, choice fed birds had higher lipid intake (129 versus 118 g/bird, P = 0.027) and selected diets with lower protein concentrations (258 versus 281 g/kg, P = 0.042) than birds offered sequential diet options. Choice fed birds had greater intakes of the high energy diet (1471 g/bird, P < 0.0001) than low energy (197 g/bird) or medium energy diets (663 g/bird) whilst broiler chickens were offered diets with different energy densities but high crude protein (300 g/kg) or digestible lysine (17.5 g/kg) concentrations. Choice fed birds had lower FCR (1.217 versus 1.327 g/g, P < 0.0001) and higher carcass yield (88.1 versus 87.3%, P = 0.012) than sequentially fed birds. This suggests that the dietary balance between protein and energy is essential for optimal feed conversion efficiency. The intake path of macronutrients from 10–31 days in choice and sequential feeding groups were plotted and compared with the null path if broiler chickens selected equal amounts of the three diets in the combination. Regardless of feeding regimen, the intake paths of starch and protein are very close to the null path; however, lipid and protein intake paths in choice fed birds are father from the null path than sequentially fed birds. PMID:29053729
Plasmon-driven sequential chemical reactions in an aqueous environment.
Zhang, Xin; Wang, Peijie; Zhang, Zhenglong; Fang, Yurui; Sun, Mengtao
2014-06-24
Plasmon-driven sequential chemical reactions were successfully realized in an aqueous environment. In an electrochemical environment, sequential chemical reactions were driven by an applied potential and laser irradiation. Furthermore, the rate of the chemical reaction was controlled via pH, which provides indirect evidence that the hot electrons generated from plasmon decay play an important role in plasmon-driven chemical reactions. In acidic conditions, the hot electrons were captured by the abundant H(+) in the aqueous environment, which prevented the chemical reaction. The developed plasmon-driven chemical reactions in an aqueous environment will significantly expand the applications of plasmon chemistry and may provide a promising avenue for green chemistry using plasmon catalysis in aqueous environments under irradiation by sunlight.
Plasmon-driven sequential chemical reactions in an aqueous environment
Zhang, Xin; Wang, Peijie; Zhang, Zhenglong; Fang, Yurui; Sun, Mengtao
2014-01-01
Plasmon-driven sequential chemical reactions were successfully realized in an aqueous environment. In an electrochemical environment, sequential chemical reactions were driven by an applied potential and laser irradiation. Furthermore, the rate of the chemical reaction was controlled via pH, which provides indirect evidence that the hot electrons generated from plasmon decay play an important role in plasmon-driven chemical reactions. In acidic conditions, the hot electrons were captured by the abundant H+ in the aqueous environment, which prevented the chemical reaction. The developed plasmon-driven chemical reactions in an aqueous environment will significantly expand the applications of plasmon chemistry and may provide a promising avenue for green chemistry using plasmon catalysis in aqueous environments under irradiation by sunlight. PMID:24958029
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoupin, Stanislav; Antipov, Sergey; Butler, James E.
Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configurationmore » and data analysis using rocking-curve topography. In conclusion, the variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.« less
Stoupin, Stanislav; Antipov, Sergey; Butler, James E; Kolyadin, Alexander V; Katrusha, Andrey
2016-09-01
Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking-curve topography. The variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.
Stoupin, Stanislav; Antipov, Sergey; Butler, James E.; ...
2016-08-10
Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configurationmore » and data analysis using rocking-curve topography. In conclusion, the variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.« less
Real-time high dynamic range laser scanning microscopy
NASA Astrophysics Data System (ADS)
Vinegoni, C.; Leon Swisher, C.; Fumene Feruglio, P.; Giedt, R. J.; Rousso, D. L.; Stapleton, S.; Weissleder, R.
2016-04-01
In conventional confocal/multiphoton fluorescence microscopy, images are typically acquired under ideal settings and after extensive optimization of parameters for a given structure or feature, often resulting in information loss from other image attributes. To overcome the problem of selective data display, we developed a new method that extends the imaging dynamic range in optical microscopy and improves the signal-to-noise ratio. Here we demonstrate how real-time and sequential high dynamic range microscopy facilitates automated three-dimensional neural segmentation. We address reconstruction and segmentation performance on samples with different size, anatomy and complexity. Finally, in vivo real-time high dynamic range imaging is also demonstrated, making the technique particularly relevant for longitudinal imaging in the presence of physiological motion and/or for quantification of in vivo fast tracer kinetics during functional imaging.
Hasegawa, Kazuo; Ichikawa, Tadashi; Mizuno, Shintaro; Takeda, Yasuhiko; Ito, Hiroshi; Ikesue, Akio; Motohiro, Tomoyoshi; Yamaga, Mitsuo
2015-06-01
We report energy transfer efficiency from Cr3+ to Nd3+ in Nd (1.0 at.%)/Cr (0.4 at.%) co-doped Y3Al5O12 (YAG) transparent ceramics in the laser oscillation states. The laser oscillation has performed using two pumping lasers operating at 808 nm and 561 nm; the former pumps Nd3+ directly to create the 1064 nm laser oscillation, whereas the latter assists the performance via Cr3+ absorption and sequential energy transfer to Nd3+. From the laser output power properties and laser mode analysis, the energy transfer efficiency was determined to be around 65%, which is close to that obtained from the spontaneous Nd3+ emission.
NASA Astrophysics Data System (ADS)
Mineo, Hirobumi; Fujimura, Yuichi
2015-06-01
We propose an ultrafast quantum switching method of π-electron rotations, which are switched among four rotational patterns in a nonplanar chiral aromatic molecule (P)-2,2’- biphenol and perform the sequential switching among four rotational patterns which are performed by the overlapped pump-dump laser pulses. Coherent π-electron dynamics are generated by applying the linearly polarized UV pulse laser to create a pair of coherent quasidegenerated excited states. We also plot the time-dependent π-electron ring current, and discussed ring current transfer between two aromatic rings.
Optically detonated explosive device
NASA Technical Reports Server (NTRS)
Yang, L. C.; Menichelli, V. J. (Inventor)
1974-01-01
A technique and apparatus for optically detonating insensitive high explosives, is disclosed. An explosive device is formed by containing high explosive material in a house having a transparent window. A thin metallic film is provided on the interior surface of the window and maintained in contact with the high explosive. A laser pulse provided by a Q-switched laser is focussed on the window to vaporize the metallic film and thereby create a shock wave which detonates the high explosive. Explosive devices may be concurrently or sequentially detonated by employing a fiber optic bundle to transmit the laser pulse to each of the several individual explosive devices.
Time-resolved non-sequential ray-tracing modelling of non-line-of-sight picosecond pulse LIDAR
NASA Astrophysics Data System (ADS)
Sroka, Adam; Chan, Susan; Warburton, Ryan; Gariepy, Genevieve; Henderson, Robert; Leach, Jonathan; Faccio, Daniele; Lee, Stephen T.
2016-05-01
The ability to detect motion and to track a moving object that is hidden around a corner or behind a wall provides a crucial advantage when physically going around the obstacle is impossible or dangerous. One recently demonstrated approach to achieving this goal makes use of non-line-of-sight picosecond pulse laser ranging. This approach has recently become interesting due to the availability of single-photon avalanche diode (SPAD) receivers with picosecond time resolution. We present a time-resolved non-sequential ray-tracing model and its application to indirect line-of-sight detection of moving targets. The model makes use of the Zemax optical design programme's capabilities in stray light analysis where it traces large numbers of rays through multiple random scattering events in a 3D non-sequential environment. Our model then reconstructs the generated multi-segment ray paths and adds temporal analysis. Validation of this model against experimental results is shown. We then exercise the model to explore the limits placed on system design by available laser sources and detectors. In particular we detail the requirements on the laser's pulse energy, duration and repetition rate, and on the receiver's temporal response and sensitivity. These are discussed in terms of the resulting implications for achievable range, resolution and measurement time while retaining eye-safety with this technique. Finally, the model is used to examine potential extensions to the experimental system that may allow for increased localisation of the position of the detected moving object, such as the inclusion of multiple detectors and/or multiple emitters.
1986-11-15
0, 2, 3.5, 5, 6.5, 8, 10, and 12 V 1 1-2 (a) Strain-Induced Band Lineups for a Free-Standing InGaAs/GaAs Superlattice. (b) Effect of Applied...Numbers of Lasers Are Operated Simultaneously (and Electrically Connected in Parallel). The Six Light Output vs Current Characteristics Shown Are Those...Lengths 11; Centered on z•,. and Constant Width Aw Are Laser-Etched Sequentially into Thin Films of Cr-Cr203 or Mo to Provide Controlled Amplitude or
Sequential analysis applied to clinical trials in dentistry: a systematic review.
Bogowicz, P; Flores-Mir, C; Major, P W; Heo, G
2008-01-01
Clinical trials employ sequential analysis for the ethical and economic benefits it brings. In dentistry, as in other fields, resources are scarce and efforts are made to ensure that patients are treated ethically. The objective of this systematic review was to characterise the use of sequential analysis for clinical trials in dentistry. We searched various databases from 1900 through to January 2008. Articles were selected for review if they were clinical trials in the field of dentistry that had applied some form of sequential analysis. Selection was carried out independently by two of the authors. We included 18 trials from various specialties, which involved many different interventions. We conclude that sequential analysis seems to be underused in this field but that there are sufficient methodological resources in place for future applications.Evidence-Based Dentistry (2008) 9, 55-62. doi:10.1038/sj.ebd.6400587.
On-Chip Laser-Power Delivery System for Dielectric Laser Accelerators
NASA Astrophysics Data System (ADS)
Hughes, Tyler W.; Tan, Si; Zhao, Zhexin; Sapra, Neil V.; Leedle, Kenneth J.; Deng, Huiyang; Miao, Yu; Black, Dylan S.; Solgaard, Olav; Harris, James S.; Vuckovic, Jelena; Byer, Robert L.; Fan, Shanhui; England, R. Joel; Lee, Yun Jo; Qi, Minghao
2018-05-01
We propose an on-chip optical-power delivery system for dielectric laser accelerators based on a fractal "tree-network" dielectric waveguide geometry. This system replaces experimentally demanding free-space manipulations of the driving laser beam with chip-integrated techniques based on precise nanofabrication, enabling access to orders-of-magnitude increases in the interaction length and total energy gain for these miniature accelerators. Based on computational modeling, in the relativistic regime, our laser delivery system is estimated to provide 21 keV of energy gain over an acceleration length of 192 μ m with a single laser input, corresponding to a 108-MV/m acceleration gradient. The system may achieve 1 MeV of energy gain over a distance of less than 1 cm by sequentially illuminating 49 identical structures. These findings are verified by detailed numerical simulation and modeling of the subcomponents, and we provide a discussion of the main constraints, challenges, and relevant parameters with regard to on-chip laser coupling for dielectric laser accelerators.
NASA Astrophysics Data System (ADS)
Nseyo, Unyime O.; Barnes, C. R.; Martin, Jessicca I.; Lamm, Donald L.; Carpenter, Cindy
2003-06-01
While 55 - 60% of newly diagnosed bladder cancers are superficial, a significant number recur as higher grade and/or stage tumors. WBPDT has been used to treat some of these recurrent superficial tumors, although its use has been associated with dose-dependent side effects. Preclinical investigation of three sequential WBPDT treatments using lower PDT dose in normal canine bladder resulted in a lack of permanent bladder contracture. Lower dose single PDT treatment has shown less durable tumor response; however, sequential WBPDT treatments with lower dose may result in durable tumor response. Five patients (4 male, 1 female), average age 65.6 (62-72 years), with recurrent or resistant superficial TCC of the bladder received two WBPDT treatments. First treatment occurred at baseline and the second treatment at 6 months. Photofrin (1.5 mg/kg) was given intravenously 48 hours prior to each cystoscopic treatment with laser light (630 nm, Coherent Lambda-Plus laser). Total light treatment doses were 1500 - 2500 Joules at baseline and 1000- 1500 Joules at 6 months. Moderate irritative bladder symptoms occurred in all patients the first week post PDT. No cases of bladder contracture have occurred. 4 of 5 patients showed no evidence of disease during the follow-up period (12 - 18 months post second treatment). One patient had a recurrence at 18 months post second treatment. Mean disease-free interval is 16.2 months. The safety of two sequential WBPDT treatments is suggested by this preliminary data. Assessment of efficacy will be possible wit a large number of patients and a longer follow-up period.
Method of and apparatus for measuring temperature and pressure. [atmospheric sounding
NASA Technical Reports Server (NTRS)
Korb, C. L.; Kalshoven, J. E., Jr. (Inventor)
1985-01-01
Laser beams are transmitted through gas to a reflecting target, which may be either a solid surface or particulate matter in gas or the gas molecules. The return beams are measured to determine the amount of energy absorbed by the gas. For temperature measurements, the laser beam has a wavelength at which the gas exhibits a relatively temperature sensitive and pressure insensitive absorption characteristic for pressure measurements, the laser beam has a wavelength at which the gas has a relatively pressure sensitive and temperature insensitive absorption characteristic. To reduce the effects of scattering on the absorption measurements a reference laser beam with a weak absorption characteristic is transmitted colinearly with the data beam having a strong absorption characteristic. The two signals are processed as a ratio to eliminate back scattering. Embodiments of transmitters and receivers described include a sequential laser pulse transmitter and receiver, a simultaneous laser pulse transmitter and receiver.
A Bayesian Theory of Sequential Causal Learning and Abstract Transfer.
Lu, Hongjing; Rojas, Randall R; Beckers, Tom; Yuille, Alan L
2016-03-01
Two key research issues in the field of causal learning are how people acquire causal knowledge when observing data that are presented sequentially, and the level of abstraction at which learning takes place. Does sequential causal learning solely involve the acquisition of specific cause-effect links, or do learners also acquire knowledge about abstract causal constraints? Recent empirical studies have revealed that experience with one set of causal cues can dramatically alter subsequent learning and performance with entirely different cues, suggesting that learning involves abstract transfer, and such transfer effects involve sequential presentation of distinct sets of causal cues. It has been demonstrated that pre-training (or even post-training) can modulate classic causal learning phenomena such as forward and backward blocking. To account for these effects, we propose a Bayesian theory of sequential causal learning. The theory assumes that humans are able to consider and use several alternative causal generative models, each instantiating a different causal integration rule. Model selection is used to decide which integration rule to use in a given learning environment in order to infer causal knowledge from sequential data. Detailed computer simulations demonstrate that humans rely on the abstract characteristics of outcome variables (e.g., binary vs. continuous) to select a causal integration rule, which in turn alters causal learning in a variety of blocking and overshadowing paradigms. When the nature of the outcome variable is ambiguous, humans select the model that yields the best fit with the recent environment, and then apply it to subsequent learning tasks. Based on sequential patterns of cue-outcome co-occurrence, the theory can account for a range of phenomena in sequential causal learning, including various blocking effects, primacy effects in some experimental conditions, and apparently abstract transfer of causal knowledge. Copyright © 2015 Cognitive Science Society, Inc.
Stable TEM00-mode Nd:YAG solar laser operation by a twisted fused silica light-guide
NASA Astrophysics Data System (ADS)
Bouadjemine, R.; Liang, D.; Almeida, J.; Mehellou, S.; Vistas, C. R.; Kellou, A.; Guillot, E.
2017-12-01
To improve the output beam stability of a TEM00-mode solar-pumped laser, a twisted fused silica light-guide was used to achieve uniform pumping along a 3 mm diameter and 50 mm length Nd:YAG rod. The concentrated solar power at the focal spot of a primary parabolic mirror with 1.18 m2 effective collection area was efficiently coupled to the entrance aperture of a 2D-CPC/2V-shaped pump cavity, within which the thin laser rod was pumped. Optimum solar laser design parameters were found through ZEMAX© non-sequential ray-tracing and LASCAD© laser cavity analysis codes. 2.3 W continuous-wave TEM00-mode 1064 nm laser power was measured, corresponding to 1.96 W/m2 collection efficiency and 2.2 W laser beam brightness figure of merit. Excellent TEM00-mode laser beam profile at M2 ≤ 1.05 and very good output power stability of less than 1.6% were achieved. Heliostat orientation error dependent laser power variation was considerably less than previous solar laser pumping schemes.
An improved scan laser with a VO2 programmable mirror
NASA Astrophysics Data System (ADS)
Chivian, J. S.; Scott, M. W.; Case, W. E.; Krasutsky, N. J.
1985-04-01
A 10.6-microns scan laser has been constructed and operated with an off-axis cathode ray tube, high reflectance multilayer thin-film structures, and a tapered plasma discharge tube. Equations are given for the switching time of a high-reflectance spot on the VO2 and for the relation of scan laser output power to cavity geometry, cavity losses, and the gain of the active CO2 medium. A scan capability of 2100 easily resolvable directions was demonstrated, and sequential and randomly addressed spot rates of 100,000/sec were achieved. The equations relating output power and cavity mode size were experimentally verified using a nonscanned beam.
Preliminary studies of radiation coupling between remote soft X-ray laser amplifiers
NASA Astrophysics Data System (ADS)
Cairns, G.; Lewis, C. L. S.; Macphee, A. G.; Neely, D.; Holden, M.; Krishnan, J.; Tallents, G. J.; Key, M. H.; Norreys, P. N.; Smith, C. G.; Zhang, J.; Holden, P. B.; Pert, G. J.; Plowes, J.; Ramsden, S. A.
1994-01-01
Coupling of a soft X-ray laser beam with a relaying concave mirror in a sequentially pumped amplifier geometry using the Ne-like Ge system has been studied experimentally. Preliminary observations indicate an increase in the spatial coherence of the amplified relayed beam. In addition, near-field imaging of one of the amplifier plasmas shows a double-lobed intensity pattern of the emergent beam indicating refractive guiding of the amplified beam with components both normal and tangential to the target surface.
Real-time high dynamic range laser scanning microscopy
Vinegoni, C.; Leon Swisher, C.; Fumene Feruglio, P.; Giedt, R. J.; Rousso, D. L.; Stapleton, S.; Weissleder, R.
2016-01-01
In conventional confocal/multiphoton fluorescence microscopy, images are typically acquired under ideal settings and after extensive optimization of parameters for a given structure or feature, often resulting in information loss from other image attributes. To overcome the problem of selective data display, we developed a new method that extends the imaging dynamic range in optical microscopy and improves the signal-to-noise ratio. Here we demonstrate how real-time and sequential high dynamic range microscopy facilitates automated three-dimensional neural segmentation. We address reconstruction and segmentation performance on samples with different size, anatomy and complexity. Finally, in vivo real-time high dynamic range imaging is also demonstrated, making the technique particularly relevant for longitudinal imaging in the presence of physiological motion and/or for quantification of in vivo fast tracer kinetics during functional imaging. PMID:27032979
Study report on laser storage and retrieval of image data
NASA Technical Reports Server (NTRS)
Becker, C. H.
1976-01-01
The theoretical foundation is presented for a system of real-time nonphotographic and nonmagnetic digital laser storage and retrieval of image data. The system utilizes diffraction-limited laser focusing upon thin metal films, melting elementary holes in the metal films in laser focus. The metal films are encapsulated in rotating flexible mylar discs which act as the permanent storage carries. Equal sized holes encompass two dimensional digital ensembles of information bits which are time-sequentially (bit by bit) stored and retrieved. The bits possess the smallest possible size, defined by the Rayleigh criterion of coherent physical optics. Space and time invariant reflective read-out of laser discs with a small laser, provides access to the stored digital information. By eliminating photographic and magnetic data processing, which characterize the previous state of the art, photographic grain, diffusion, and gamma-distortion do not exist. Similarly, magnetic domain structures, magnetic gaps, and magnetic read-out are absent with a digital laser disc system.
Nuclear interference in the Coulomb explosion of H2+ in short vuv laser fields.
Førre, Morten; Barmaki, Samira; Bachau, Henri
2009-03-27
We report ab initio calculations of H2+ three-photon ionization by vuv/fs 10(12) W/cm(2) laser pulses including electronic and vibrational degrees of freedom in the Born-Oppenheimer approximation. The initial nuclear wave packet of H2+(1ssigma(g)) is assumed to be equal to the H2 vibrational ground state. For pulse durations longer than 10 fs, we find an unexpected modulation in the kinetic energy spectra of the correlated fragments (H++H+). It is shown that the structures in the spectra originate from the interference between a direct and a sequential dissociation channel. While the first channel is open even for relatively short pulses, the sequential one only opens for pulse durations longer than 10 fs. In the latter case we show that interference between the two components results in a modulated kinetic energy release spectrum in the dissociation channel 3dsigma(g), which is reflected in the ionization spectrum.
Sequential motion of the ossicular chain measured by laser Doppler vibrometry.
Kunimoto, Yasuomi; Hasegawa, Kensaku; Arii, Shiro; Kataoka, Hideyuki; Yazama, Hiroaki; Kuya, Junko; Fujiwara, Kazunori; Takeuchi, Hiromi
2017-12-01
In order to help a surgeon make the best decision, a more objective method of measuring ossicular motion is required. A laser Doppler vibrometer was mounted on a surgical microscope. To measure ossicular chain vibrations, eight patients with cochlear implants were investigated. To assess the motions of the ossicular chain, velocities at five points were measured with tonal stimuli of 1 and 3 kHz, which yielded reproducible results. The sequential amplitude change at each point was calculated with phase shifting from the tonal stimulus. Motion of the ossicular chain was visualized from the averaged results using the graphics application. The head of the malleus and the body of the incus showed synchronized movement as one unit. In contrast, the stapes (incudostapedial joint and posterior crus) moved synchronously in opposite phase to the malleus and incus. The amplitudes at 1 kHz were almost twice those at 3 kHz. Our results show that the malleus and incus unit and the stapes move with a phase difference.
Adrenal vein sampling in primary aldosteronism: concordance of simultaneous vs sequential sampling.
Almarzooqi, Mohamed-Karji; Chagnon, Miguel; Soulez, Gilles; Giroux, Marie-France; Gilbert, Patrick; Oliva, Vincent L; Perreault, Pierre; Bouchard, Louis; Bourdeau, Isabelle; Lacroix, André; Therasse, Eric
2017-02-01
Many investigators believe that basal adrenal venous sampling (AVS) should be done simultaneously, whereas others opt for sequential AVS for simplicity and reduced cost. This study aimed to evaluate the concordance of sequential and simultaneous AVS methods. Between 1989 and 2015, bilateral simultaneous sets of basal AVS were obtained twice within 5 min, in 188 consecutive patients (59 women and 129 men; mean age: 53.4 years). Selectivity was defined by adrenal-to-peripheral cortisol ratio ≥2, and lateralization was defined as an adrenal aldosterone-to-cortisol ratio ≥2, the contralateral side. Sequential AVS was simulated using right sampling at -5 min (t = -5) and left sampling at 0 min (t = 0). There was no significant difference in mean selectivity ratio (P = 0.12 and P = 0.42 for the right and left sides respectively) and in mean lateralization ratio (P = 0.93) between t = -5 and t = 0. Kappa for selectivity between 2 simultaneous AVS was 0.71 (95% CI: 0.60-0.82), whereas it was 0.84 (95% CI: 0.76-0.92) and 0.85 (95% CI: 0.77-0.93) between sequential and simultaneous AVS at respectively -5 min and at 0 min. Kappa for lateralization between 2 simultaneous AVS was 0.84 (95% CI: 0.75-0.93), whereas it was 0.86 (95% CI: 0.78-0.94) and 0.80 (95% CI: 0.71-0.90) between sequential AVS and simultaneous AVS at respectively -5 min at 0 min. Concordance between simultaneous and sequential AVS was not different than that between 2 repeated simultaneous AVS in the same patient. Therefore, a better diagnostic performance is not a good argument to select the AVS method. © 2017 European Society of Endocrinology.
Chan, Jeffrey Chi Wang; Choy, Bonnie Nga Kwan; Chan, Orlando Chia Chieh; Li, Kenneth Kai Wang
2018-02-01
Our purpose was to assess the early intraocular pressure (IOP) changes of ultralow fluence laser iridotomy using pattern scanning laser followed by neodymium:yttrium-aluminum-gamet (Nd:YAG) laser. This is a prospective interventional study. Thirty-three eyes of 33 adult Chinese primary angle-closure suspect subjects were recruited for prophylactic laser peripheral iridotomy. Sequential laser peripheral iridotomy was performed using pattern scanning laser followed by Nd:YAG laser. Visual acuity (VA) and IOP were measured before treatment, at 1 h, 1 day, 1 week, 1 month, 3 months and 6 months after laser. Laser energy used and complications were documented. Corneal endothelial cell count was examined at baseline and 6 months. Patency of the iridotomy was assessed at each follow-up visit. All subjects achieved patent iridotomy in a single session. The mean energy used was 0.335+/-0.088 J for the pattern scanning laser, and 4.767+/-5.780 mJ for the Nd:YAG laser. The total mean energy was 0.339+/-0.089 J. None of the eyes developed a clinically significant IOP spike (≥ 8 mmHg) at 1 h and 1 day after laser use. Only four eyes developed higher IOP at 1 h and all were ≤3 mmHg compared to baseline. The mean IOP was 13.8+/-2.5 mmHg at 1 h and 11.5+/-2.2 mmHg at 1 day, both were significantly lower than baseline (15.8+/-2.1 mmHg) (P < 0.001). Mean VA (logMAR) was similar at 1 h post laser compared to baseline (0.23 vs 0.26). There was also no statistically significant difference in mean VA at other follow-up visits compared to baseline. Peripheral iridotomy closure was encountered in two (6.1%) eyes, one at 1 month and another at 6 months follow-up. There were no complications including hyphema, peripheral anterior synechia formation nor prolonged inflammation throughout the follow-up period. There was no significant loss in corneal endothelial cell counts at 6 months (2255+/-490) compared to baseline (2303+/-386) (P = 0.347). Sequential LPI using an ultralow fluence pattern scanning laser, followed by a Nd:YAG laser, is safe and efficacious, and produces no IOP spike in dark irides of primary angle-closure suspects. Further studies to investigate its role in the treatment of other angle-closure conditions are warranted.
Sequential double photodetachment of He- in elliptically polarized laser fields
NASA Astrophysics Data System (ADS)
Génévriez, Matthieu; Dunseath, Kevin M.; Terao-Dunseath, Mariko; Urbain, Xavier
2018-02-01
Four-photon double detachment of the helium negative ion is investigated experimentally and theoretically for photon energies where the transient helium atom is in the 1 s 2 s 3S or 1 s 2 p P3o states, which subsequently ionize by absorption of three photons. Ionization is enhanced by intermediate resonances, giving rise to series of peaks in the He+ spectrum, which we study in detail. The He+ yield is measured in the wavelength ranges from 530 to 560 nm and from 685 to 730 nm and for various polarizations of the laser light. Double detachment is treated theoretically as a sequential process, within the framework of R -matrix theory for the first step and effective Hamiltonian theory for the second step. Experimental conditions are accurately modeled, and the measured and simulated yields are in good qualitative and, in some cases, quantitative agreement. Resonances in the double detachment spectra can be attributed to well-defined Rydberg states of the transient atom. The double detachment yield exhibits a strong dependence on the laser polarization which can be related to the magnetic quantum number of the intermediate atomic state. We also investigate the possibility of nonsequential double detachment with a two-color experiment but observe no evidence for it.
Todoroki, Shin-ichi
2008-01-01
Background Fiber fuse is a process of optical fiber destruction under the action of laser radiation, found 20 years ago. Once initiated, opical discharge runs along the fiber core region to the light source and leaves periodic voids whose shape looks like a bullet pointing the direction of laser beam. The relation between damage pattern and propagation mode of optical discharge is still unclear even after the first in situ observation three years ago. Methodology/Principal Findings Fiber fuse propagation over hetero-core splice point (Corning SMF-28e and HI 1060) was observed in situ. Sequential photographs obtained at intervals of 2.78 µs recorded a periodic emission at the tail of an optical discharge pumped by 1070 nm and 9 W light. The signal stopped when the discharge ran over the splice point. The corresponding damage pattern left in the fiber core region included a segment free of periodicity. Conclusions The spatial modulation pattern of the light emission agreed with the void train formed over the hetero-core splice point. Some segments included a bullet-shaped void pointing in the opposite direction to the laser beam propagation although the sequential photographs did not reveal any directional change in the optical discharge propagation. PMID:18815621
Laser-driven ultrafast antiproton beam
NASA Astrophysics Data System (ADS)
Li, Shun; Pei, Zhikun; Shen, Baifei; Xu, Jiancai; Zhang, Lingang; Zhang, Xiaomei; Xu, Tongjun; Yu, Yong; Bu, Zhigang
2018-02-01
Antiproton beam generation is investigated based on the ultra-intense femtosecond laser pulse by using two-dimensional particle-in-cell and Geant4 simulations. A high-flux proton beam with an energy of tens of GeV is generated in sequential radiation pressure and bubble regime and then shoots into a high-Z target for producing antiprotons. Both yield and energy of the antiproton beam increase almost linearly with the laser intensity. The generated antiproton beam has a short pulse duration of about 5 ps and its flux reaches 2 × 10 20 s - 1 at the laser intensity of 2.14 × 10 23 W / cm 2 . Compared to conventional methods, this new method based on the ultra-intense laser pulse is able to provide a compact, tunable, and ultrafast antiproton source, which is potentially useful for quark-gluon plasma study, all-optical antihydrogen generation, and so on.
High voltage power supply with modular series resonant inverters
Dreifuerst, Gary R.; Merritt, Bernard T.
1995-01-01
A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.
High voltage power supply with modular series resonant inverters
Dreifuerst, G.R.; Merritt, B.T.
1995-07-18
A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.
High Temperature Superconductor/Semiconductor Hybrid Microwave Devices and Circuits
NASA Technical Reports Server (NTRS)
Romanofsky, Robert R.; Miranda, Felix A.
1999-01-01
Contents include following: film deposition technique; laser ablation; magnetron sputtering; sequential evaporation; microwave substrates; film characterization at microwave frequencies; complex conductivity; magnetic penetration depth; surface impedance; planar single-mode filters; small antennas; antenna arrays phase noise; tunable oscillations; hybrid superconductor/semiconductor receiver front ends; and noise modeling.
Effect of high-flux H/He plasma exposure on tungsten damage due to transient heat loads
NASA Astrophysics Data System (ADS)
De Temmerman, G.; Morgan, T. W.; van Eden, G. G.; de Kruif, T.; Wirtz, M.; Matejicek, J.; Chraska, T.; Pitts, R. A.; Wright, G. M.
2015-08-01
The thermal shock behaviour of tungsten exposed to high-flux plasma is studied using a high-power laser. The cases of laser-only, sequential laser and hydrogen (H) plasma and simultaneous laser plus H plasma exposure are studied. H plasma exposure leads to an embrittlement of the material and the appearance of a crack network originating from the centre of the laser spot. Under simultaneous loading, significant surface melting is observed. In general, H plasma exposure lowers the heat flux parameter (FHF) for the onset of surface melting by ∼25%. In the case of He-modified (fuzzy) surfaces, strong surface deformations are observed already after 1000 laser pulses at moderate FHF = 19 MJ m-2 s-1/2, and a dense network of fine cracks is observed. These results indicate that high-fluence ITER-like plasma exposure influences the thermal shock properties of tungsten, lowering the permissible transient energy density beyond which macroscopic surface modifications begin to occur.
Lee, Sang Ju; Kim, Young Koo; Choi, Sun Young; Park, Kui Young; Seo, Seong Jun
2014-01-01
Boxcar scars, such as chicken pox scars, are round to oval depressions with sharply defined vertical edges. Subcision is a simple and safe procedure for treatment of atrophic and depressed scars, but boxcar scars are generally not eliminated by subcision. Intradermal incision technique (intracision) can treat chicken pox scars by untethering fibrotic strands, raising collagen synthesis, and having additional intradermal blood pocket formation. We have found that chicken pox scars further improve when intracision is followed by laser skin resurfacing. © 2013 Wiley Periodicals, Inc.
1986-01-06
D.E. Reisner, and P.H. Vaccaro, pp. 393-404 in Lasers as Reactants and Probes in Chemistry, (eds. W.M. Jackson and A.B. Harvey) Howard University Press...as Reactants and Probes in Chemistry, Howard University (May 1982). 4. J.L. Kinsey, "An Outsider’s View of the Spectroscopy of Polyatomic Systems...Kinsey, C. Kittrell, D.E. Reisner, and P.H. Vaccaro, pp. 393-404 in Lasers as Reactants and Probes in Chemistry (eds. W.M. Jackson and A.B. Harvey), Howard
NASA Astrophysics Data System (ADS)
Zhaunerchyk, V.; Kamińska, M.; Mucke, M.; Squibb, R. J.; Eland, J. H. D.; Piancastelli, M. N.; Frasinski, L. J.; Grilj, J.; Koch, M.; McFarland, B. K.; Sistrunk, E.; Gühr, M.; Coffee, R. N.; Bostedt, C.; Bozek, J. D.; Salén, P.; Meulen, P. v. d.; Linusson, P.; Thomas, R. D.; Larsson, M.; Foucar, L.; Ullrich, J.; Motomura, K.; Mondal, S.; Ueda, K.; Richter, R.; Prince, K. C.; Takahashi, O.; Osipov, T.; Fang, L.; Murphy, B. F.; Berrah, N.; Feifel, R.
2015-12-01
Competing multi-photon ionization processes, some leading to the formation of double core hole states, have been examined in 4-aminophenol. The experiments used the linac coherent light source (LCLS) x-ray free electron laser, in combination with a time-of-flight magnetic bottle electron spectrometer and the correlation analysis method of covariance mapping. The results imply that 4-aminophenol molecules exposed to the focused x-ray pulses of the LCLS sequentially absorb more than two x-ray photons, resulting in the formation of multiple core holes as well as in the sequential removal of photoelectrons and Auger electrons (so-called PAPA sequences).
Zhaunerchyk, V.; Kaminska, M.; Mucke, M.; ...
2015-10-28
Competing multi-photon ionization processes, some leading to the formation of double core hole states, have been examined in 4-aminophenol. The experiments used the linac coherent light source (LCLS) x-ray free electron laser, in combination with a time-of-flight magnetic bottle electron spectrometer and the correlation analysis method of covariance mapping. Furthermore, the results imply that 4-aminophenol molecules exposed to the focused x-ray pulses of the LCLS sequentially absorb more than two x-ray photons, resulting in the formation of multiple core holes as well as in the sequential removal of photoelectrons and Auger electrons (so-called PAPA sequences).
Iterative non-sequential protein structural alignment.
Salem, Saeed; Zaki, Mohammed J; Bystroff, Christopher
2009-06-01
Structural similarity between proteins gives us insights into their evolutionary relationships when there is low sequence similarity. In this paper, we present a novel approach called SNAP for non-sequential pair-wise structural alignment. Starting from an initial alignment, our approach iterates over a two-step process consisting of a superposition step and an alignment step, until convergence. We propose a novel greedy algorithm to construct both sequential and non-sequential alignments. The quality of SNAP alignments were assessed by comparing against the manually curated reference alignments in the challenging SISY and RIPC datasets. Moreover, when applied to a dataset of 4410 protein pairs selected from the CATH database, SNAP produced longer alignments with lower rmsd than several state-of-the-art alignment methods. Classification of folds using SNAP alignments was both highly sensitive and highly selective. The SNAP software along with the datasets are available online at http://www.cs.rpi.edu/~zaki/software/SNAP.
Qu, Xiangmeng; Li, Min; Zhang, Hongbo; Lin, Chenglie; Wang, Fei; Xiao, Mingshu; Zhou, Yi; Shi, Jiye; Aldalbahi, Ali; Pei, Hao; Chen, Hong; Li, Li
2017-09-20
The development of a real-time continuous analytical platform for the pathogen detection is of great scientific importance for achieving better disease control and prevention. In this work, we report a rapid and recyclable microfluidic bioassay system constructed from oligonucleotide arrays for selective and sensitive continuous identification of DNA targets of fungal pathogens. We employ the thermal denaturation method to effectively regenerate the oligonucleotide arrays for multiple sample detection, which could considerably reduce the screening effort and costs. The combination of thermal denaturation and laser-induced fluorescence detection technique enables real-time continuous identification of multiple samples (<10 min per sample). As a proof of concept, we have demonstrated that two DNA targets of fungal pathogens (Botrytis cinerea and Didymella bryoniae) can be sequentially analyzed using our rapid microfluidic bioassay system, which provides a new paradigm in the design of microfluidic bioassay system and will be valuable for chemical and biomedical analysis.
Preliminary Design of a Digital Holography PFC Erosion Diagnostic for MPEX
NASA Astrophysics Data System (ADS)
Thomas, C. E. (Tommy), Jr.; Biewer, T. M.; Shaw, G. C.; Baylor, L. R.; Combs, S. K.; Meitner, S. J.; Rapp, J.; Hillis, D. L.; Granstedt, E. M.; Majeski, R.; Kaita, R.
2015-11-01
Preliminary design of a Digital Holography (DH) in-situ Plasma Facing Component (PFC) erosion diagnostic to be used on the proto-MPEX/MPEX experiment is presented. Design trade-offs are discussed including the selection of CO2 laser frequencies and whether/where to use reflective or refractive optical components. The costs and benefits of using a high-speed (expensive) infrared (IR) camera or a lower speed (inexpensive) IR camera, and whether to use simultaneous or sequential acquisition of DH exposures for the dual wavelength system are also described. Expected layout, resolution, and noise figures will be discussed, along with resolution and noise data from previous work at ORNL and PPPL. Partial Support from USDOE Contract DE-AC02-09CH11466 and USDOE Grant DE-FG02-07ER84724 for previous Digital Holography work done at ORNL and PPPL is gratefully acknowledged.
NASA Astrophysics Data System (ADS)
Van Malderen, Stijn J. M.; van Elteren, Johannes T.; Šelih, Vid S.; Vanhaecke, Frank
2018-02-01
This work describes the aliasing effects induced by undersampling the high-frequency signal patterns generated by a laser ablation-inductively coupled plasma-mass spectrometer equipped with a low-dispersion ablation cell and sequential mass analyzer. By characterizing the width of the signal peak generated from a single shot on the sample, critical experimental parameters, such as the laser repetition rate and detector cycle timings for the individual nuclides can be matched so as to avoid these imaging artifacts (spectral skew) induced by an insufficient sampling rate. By increasing the laser repetition rate by a factor 2-3, masses at the end of the mass scan can be sampled at higher sensitivity. Furthermore, the dwell times can be redistributed over the nuclides of interest based on the signal-to-noise ratio to increase the image contrast.
A sampling and classification item selection approach with content balancing.
Chen, Pei-Hua
2015-03-01
Existing automated test assembly methods typically employ constrained combinatorial optimization. Constructing forms sequentially based on an optimization approach usually results in unparallel forms and requires heuristic modifications. Methods based on a random search approach have the major advantage of producing parallel forms sequentially without further adjustment. This study incorporated a flexible content-balancing element into the statistical perspective item selection method of the cell-only method (Chen et al. in Educational and Psychological Measurement, 72(6), 933-953, 2012). The new method was compared with a sequential interitem distance weighted deviation model (IID WDM) (Swanson & Stocking in Applied Psychological Measurement, 17(2), 151-166, 1993), a simultaneous IID WDM, and a big-shadow-test mixed integer programming (BST MIP) method to construct multiple parallel forms based on matching a reference form item-by-item. The results showed that the cell-only method with content balancing and the sequential and simultaneous versions of IID WDM yielded results comparable to those obtained using the BST MIP method. The cell-only method with content balancing is computationally less intensive than the sequential and simultaneous versions of IID WDM.
Yu, Yinan; Diamantaras, Konstantinos I; McKelvey, Tomas; Kung, Sun-Yuan
2018-02-01
In kernel-based classification models, given limited computational power and storage capacity, operations over the full kernel matrix becomes prohibitive. In this paper, we propose a new supervised learning framework using kernel models for sequential data processing. The framework is based on two components that both aim at enhancing the classification capability with a subset selection scheme. The first part is a subspace projection technique in the reproducing kernel Hilbert space using a CLAss-specific Subspace Kernel representation for kernel approximation. In the second part, we propose a novel structural risk minimization algorithm called the adaptive margin slack minimization to iteratively improve the classification accuracy by an adaptive data selection. We motivate each part separately, and then integrate them into learning frameworks for large scale data. We propose two such frameworks: the memory efficient sequential processing for sequential data processing and the parallelized sequential processing for distributed computing with sequential data acquisition. We test our methods on several benchmark data sets and compared with the state-of-the-art techniques to verify the validity of the proposed techniques.
Laser Sources for Generation of Ultrasound
NASA Technical Reports Server (NTRS)
Wagner, James W.
1996-01-01
Two laser systems have been built and used to demonstrate enhancements beyond current technology used for laser-based generation and detection of ultrasound. The first system consisted of ten Nd:YAG laser cavities coupled electronically and optically to permit sequential bursts of up to ten laser pulses directed either at a single point or configured into a phased array of sources. Significant enhancements in overall signal-to-noise ratio for laser ultrasound incorporating this new source system was demonstrated, using it first as a source of narrowband ultrasound and secondly as a phased array source producing large enhanced signal displacements. A second laser system was implemented using ultra fast optical pulses from a Ti:Sapphire laser to study a new method for making laser generated ultrasonic measurements of thin films with thicknesses on the order of hundreds of angstroms. Work by prior investigators showed that such measurements could be made based upon fluctuations in the reflectivity of thin films when they are stressed by an arriving elastic pulse. Research performed using equipment purchased under this program showed that a pulsed interferometric system could be used as well as a piezoreflective detection system to measure pulse arrivals even in thin films with very low piezoreflective coefficients.
Multi-point laser coherent detection system and its application on vibration measurement
NASA Astrophysics Data System (ADS)
Fu, Y.; Yang, C.; Xu, Y. J.; Liu, H.; Yan, K.; Guo, M.
2015-05-01
Laser Doppler vibrometry (LDV) is a well-known interferometric technique to measure the motions, vibrations and mode shapes of machine components and structures. The drawback of commercial LDV is that it can only offer a pointwise measurement. In order to build up a vibrometric image, a scanning device is normally adopted to scan the laser point in two spatial axes. These scanning laser Doppler vibrometers (SLDV) assume that the measurement conditions remain invariant while multiple and identical, sequential measurements are performed. This assumption makes SLDVs impractical to do measurement on transient events. In this paper, we introduce a new multiple-point laser coherent detection system based on spatial-encoding technology and fiber configuration. A simultaneous vibration measurement on multiple points is realized using a single photodetector. A prototype16-point laser coherent detection system is built and it is applied to measure the vibration of various objects, such as body of a car or a motorcycle when engine is on and under shock tests. The results show the prospect of multi-point laser coherent detection system in the area of nondestructive test and precise dynamic measurement.
Sequential Double lonization: The Timing of Release
NASA Astrophysics Data System (ADS)
Pfeiffer, A.
2011-05-01
The timing of electron release in strong field double ionization poses great challenges both for conceptual definition and for conducting experimental measurement. Here we present coincidence momentum measurements of the doubly charged ion and of the two electrons arising from double ionization of Argon using elliptically (close to circularly) polarized laser pulses. Based on a semi-classical model, the ionization times are calculated from the measured electron momenta across a large intensity range. Exploiting the attoclock technique we have direct access to timings on a coarse and on a fine scale, similar to the hour and the minute hand of a clock. In our attoclock, the magnitude of the electron momenta follows the envelope of the laser pulse and gives a coarse timing for the electron releases (the hour hand), while the fine timing (the minute hand) is provided by the emission angle of the electrons. The first of our findings is that due to depletion the averaged ionization time moves towards the beginning of the pulse with increasing intensity, confirming the results of Maharjan et al., and that the ion momentum distribution projected onto the minor polarization axis shows a bifurcation from a 3-peak to a 4-peak structure. This effect can be fully understood by modeling the process semi-classically in the independent electron approximation following the simple man's model. The ionization time measurement performed with the attoclock shows that the release time of the first electron is in good agreement with the semi-classical simulation performed on the basis of Sequential Double lonization (SDI), whereas the ionization of the second electron occurs significantly earlier than predicted. This observation suggests that electron correlation and other Non-Sequential Double lonization (NSDI) mechanisms may play an important role also in the case of strong field double ionization by close-to-circularly polarized laser pulses. The timing of electron release in strong field double ionization poses great challenges both for conceptual definition and for conducting experimental measurement. Here we present coincidence momentum measurements of the doubly charged ion and of the two electrons arising from double ionization of Argon using elliptically (close to circularly) polarized laser pulses. Based on a semi-classical model, the ionization times are calculated from the measured electron momenta across a large intensity range. Exploiting the attoclock technique we have direct access to timings on a coarse and on a fine scale, similar to the hour and the minute hand of a clock. In our attoclock, the magnitude of the electron momenta follows the envelope of the laser pulse and gives a coarse timing for the electron releases (the hour hand), while the fine timing (the minute hand) is provided by the emission angle of the electrons. The first of our findings is that due to depletion the averaged ionization time moves towards the beginning of the pulse with increasing intensity, confirming the results of Maharjan et al., and that the ion momentum distribution projected onto the minor polarization axis shows a bifurcation from a 3-peak to a 4-peak structure. This effect can be fully understood by modeling the process semi-classically in the independent electron approximation following the simple man's model. The ionization time measurement performed with the attoclock shows that the release time of the first electron is in good agreement with the semi-classical simulation performed on the basis of Sequential Double lonization (SDI), whereas the ionization of the second electron occurs significantly earlier than predicted. This observation suggests that electron correlation and other Non-Sequential Double lonization (NSDI) mechanisms may play an important role also in the case of strong field double ionization by close-to-circularly polarized laser pulses. In collaboration with C. Cirelli and M. Smolarski, Physics Department, ETH Zurich, 8093 Zurich, Switzerland; R. Doerner, Institut fiir Kernphysik, Johann Wolfgang Goethe Universitat, 60438 Frankfurt am Main, Germany; and U. Keller, ETH Zurich.
Pulsed x-ray imaging of high-density objects using a ten picosecond high-intensity laser driver
NASA Astrophysics Data System (ADS)
Rusby, D. R.; Brenner, C. M.; Armstrong, C.; Wilson, L. A.; Clarke, R.; Alejo, A.; Ahmed, H.; Butler, N. M. H.; Haddock, D.; Higginson, A.; McClymont, A.; Mirfayzi, S. R.; Murphy, C.; Notley, M.; Oliver, P.; Allott, R.; Hernandez-Gomez, C.; Kar, S.; McKenna, P.; Neely, D.
2016-10-01
Point-like sources of X-rays that are pulsed (sub nanosecond), high energy (up to several MeV) and bright are very promising for industrial and security applications where imaging through large and dense objects is required. Highly penetrating X-rays can be produced by electrons that have been accelerated by a high intensity laser pulse incident onto a thin solid target. We have used a pulse length of 10ps to accelerate electrons to create a bright x-ray source. The bremsstrahlung temperature was measured for a laser intensity from 8.5-12×1018 W/cm2. These x-rays have sequentially been used to image high density materials using image plate and a pixelated scintillator system.
Freeze frame analysis on high speed cinematography of Nd/YAG laser explosions in ocular tissues.
Vernon, S A; Cheng, H
1986-05-01
High speed colour cinematography at 400 frames per second was used to photograph both single and train burst Nd/YAG laser applications in ox eyes at threshold energy levels. Measurements of the extent and speed of particle scatter and tissue distortion from the acoustic transient were made from a sequential freeze frame analysis of the films. Particles were observed to travel over 8 mm from the site of Nd/YAG application 20 milliseconds after a single pulse at initial speeds in excess of 20 km/h. The use of train bursts of pulses was seen to increase the number of particles scattered and project the wavefront of particles further from the point of laser application.
Freeze frame analysis on high speed cinematography of Nd/YAG laser explosions in ocular tissues.
Vernon, S A; Cheng, H
1986-01-01
High speed colour cinematography at 400 frames per second was used to photograph both single and train burst Nd/YAG laser applications in ox eyes at threshold energy levels. Measurements of the extent and speed of particle scatter and tissue distortion from the acoustic transient were made from a sequential freeze frame analysis of the films. Particles were observed to travel over 8 mm from the site of Nd/YAG application 20 milliseconds after a single pulse at initial speeds in excess of 20 km/h. The use of train bursts of pulses was seen to increase the number of particles scattered and project the wavefront of particles further from the point of laser application. Images PMID:3754458
Drug injection into fat tissue with a laser based microjet injector
NASA Astrophysics Data System (ADS)
Han, Tae-hee; Hah, Jung-moo; Yoh, Jack J.
2011-05-01
We have investigated a new micro drug jet injector using laser pulse energy. An infrared laser beam of high energy (˜3 J/pulse) is focused inside a driving fluid in a small chamber. The pulse then induces various energy releasing processes, and generates fast microjets through a micronozzle. The elastic membrane of this system plays an important role in transferring mechanical pressure and protecting drug from heat release. In this paper, we offer the sequential images of microjet generation taken by a high speed camera as an evidence of the multiple injections via single pulse. Furthermore, we test the proposed system to penetrate soft animal tissues in order to evaluate its feasibility as an advanced transdermal drug delivery method.
Sequential cryogen spraying for heat flux control at the skin surface
NASA Astrophysics Data System (ADS)
Majaron, Boris; Aguilar, Guillermo; Basinger, Brooke; Randeberg, Lise L.; Svaasand, Lars O.; Lavernia, Enrique J.; Nelson, J. Stuart
2001-05-01
Heat transfer rate at the skin-air interface is of critical importance for the benefits of cryogen spray cooling in combination with laser therapy of shallow subsurface skin lesions, such as port-wine stain birthmarks. With some cryogen spray devices, a layer of liquid cryogen builds up on the skin surface during the spurt, which may impair heat transfer across the skin surface due to relatively low thermal conductivity and potentially higher temperature of the liquid cryogen layer as compared to the spray droplets. While the mass flux of cryogen delivery can be adjusted by varying the atomizing nozzle geometry, this may strongly affect other spray properties, such as lateral spread (cone), droplet size, velocity, and temperature distribution. We present here first experiments with sequential cryogen spraying, which may enable accurate mass flux control through variation of spray duty cycle, while minimally affecting other spray characteristics. The observed increase of cooling rate and efficiency at moderate duty cycle levels supports the above described hypothesis of isolating liquid layer, and demonstrates a novel approach to optimization of cryogen spray devices for individual laser dermatological applications.
Ishii, Katsunori; Saiki, Masayuki; Hazama, Hisanao; Awazu, Kunio
2010-01-01
Mid-infrared (MIR) laser with a specific wavelength can excite the corresponding biomolecular site to regulate chemical, thermal and mechanical interactions to biological molecules and tissues. In laser surgery and medicine, tunable MIR laser irradiation can realize the selective and less-invasive treatments and the special diagnosis by vibrational spectroscopic information. This paper showed a novel selective therapeutic technique for a laser angioplasty of atherosclerotic plaques and a laser dental surgery of a carious dentin using a MIR tunable nanosecond pulsed laser.
NASA Technical Reports Server (NTRS)
Hartman, Brian Davis
1995-01-01
A key drawback to estimating geodetic and geodynamic parameters over time based on satellite laser ranging (SLR) observations is the inability to accurately model all the forces acting on the satellite. Errors associated with the observations and the measurement model can detract from the estimates as well. These 'model errors' corrupt the solutions obtained from the satellite orbit determination process. Dynamical models for satellite motion utilize known geophysical parameters to mathematically detail the forces acting on the satellite. However, these parameters, while estimated as constants, vary over time. These temporal variations must be accounted for in some fashion to maintain meaningful solutions. The primary goal of this study is to analyze the feasibility of using a sequential process noise filter for estimating geodynamic parameters over time from the Laser Geodynamics Satellite (LAGEOS) SLR data. This evaluation is achieved by first simulating a sequence of realistic LAGEOS laser ranging observations. These observations are generated using models with known temporal variations in several geodynamic parameters (along track drag and the J(sub 2), J(sub 3), J(sub 4), and J(sub 5) geopotential coefficients). A standard (non-stochastic) filter and a stochastic process noise filter are then utilized to estimate the model parameters from the simulated observations. The standard non-stochastic filter estimates these parameters as constants over consecutive fixed time intervals. Thus, the resulting solutions contain constant estimates of parameters that vary in time which limits the temporal resolution and accuracy of the solution. The stochastic process noise filter estimates these parameters as correlated process noise variables. As a result, the stochastic process noise filter has the potential to estimate the temporal variations more accurately since the constraint of estimating the parameters as constants is eliminated. A comparison of the temporal resolution of solutions obtained from standard sequential filtering methods and process noise sequential filtering methods shows that the accuracy is significantly improved using process noise. The results show that the positional accuracy of the orbit is improved as well. The temporal resolution of the resulting solutions are detailed, and conclusions drawn about the results. Benefits and drawbacks of using process noise filtering in this type of scenario are also identified.
Atmospheric methane measurement instrument using a Zeeman-split He-Ne laser
NASA Technical Reports Server (NTRS)
Mcmanus, J. Barry; Kebabian, Paul L.; Kolb, Charles E.
1989-01-01
The construction of an atmospheric methane measurement instrument based on a Zeeman-split IR He-Ne laser is reported. The laser has a tranverse magnetic field over about 2/3 of its gain length and can oscillate at an (unsplit) frequency (2947.91/cm) centered on a methane absorption line, or on either of two frequencies split by + or - 0.055/cm from the center, with low CH4 absorption. The laser is tuned to dwell sequentially at each frequency, giving two differential absorption measurements in each 46-ms tuning cycle. Atmospheric measurements are made using two multiple pass absorption cells, one with fast (0.75-s) and one with slow (5-s) flow response times. Fluctuations in ambient CH4 of about 20-ppb (rms, 1-s averaging) are detected, with interference fringe effects the dominant noise source. The instrument has operated in a field experiment (NASA GTE/ABLE-3A) in Alaska.
NASA Astrophysics Data System (ADS)
Nekouie Esfahani, M. R.; Coupland, J.; Marimuthu, S.
2015-07-01
This study reports an experimental and numerical investigation on controlling the microstructure and brittle phase formation during laser dissimilar welding of carbon steel to austenitic stainless steel. The significance of alloying composition and cooling rate were experimentally investigated. The investigation revealed that above a certain specific point energy the material within the melt pool is well mixed and the laser beam position can be used to control the mechanical properties of the joint. The heat-affected zone within the high-carbon steel has significantly higher hardness than the weld area, which severely undermines the weld quality. A sequentially coupled thermo-metallurgical model was developed to investigate various heat-treatment methodology and subsequently control the microstructure of the HAZ. Strategies to control the composition leading to dramatic changes in hardness, microstructure and service performance of the dissimilar laser welded fusion zone are discussed.
Kafka, K R P; Austin, D R; Li, H; Yi, A Y; Cheng, J; Chowdhury, E A
2015-07-27
Time-resolved diffraction microscopy technique has been used to observe the formation of laser-induced periodic surface structures (LIPSS) from the interaction of a single femtosecond laser pulse (pump) with a nano-scale groove mechanically formed on a single-crystal Cu substrate. The interaction dynamics (0-1200 ps) was captured by diffracting a time-delayed, frequency-doubled pulse (probe) from nascent LIPSS formation induced by the pump with an infinity-conjugate microscopy setup. The LIPSS ripples are observed to form asynchronously, with the first one forming after 50 ps and others forming sequentially outward from the groove edge at larger time delays. A 1-D analytical model of electron heating including both the laser pulse and surface plasmon polariton excitation at the groove edge predicts ripple period, melt spot diameter, and qualitatively explains the asynchronous time-evolution of LIPSS formation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Weina; Jiang, Lan; Li, Xiaowei, E-mail: lixiaowei@bit.edu.cn
We report an extra freedom to modulate the femtosecond laser energy distribution to control the surface ablated structures through a copper-grid mask. Due to the reduced deposited pulse energy by changing the scanning speed or the pulse fluence, a sequential evolution of three distinctly different surface patterns with periodic distributions is formed, namely, striped ripple lines, ripple microdots, and surface modification. By changing the scanning speed, the number of the multiple dots in a lattice can be modulated. Moreover, by exploring the ablation process through the copper grid mask, it shows an abnormal enhanced ablation effect with strong dependence ofmore » the diffraction-aided fs laser ablated surface structures on polarization direction. The sensitivity shows a quasi-cosinusoid-function with a periodicity of π/2. Particularly, the connection process of striped ripple lines manifests a preferential formation direction with the laser polarization.« less
Learning Behavior Characterization with Multi-Feature, Hierarchical Activity Sequences
ERIC Educational Resources Information Center
Ye, Cheng; Segedy, James R.; Kinnebrew, John S.; Biswas, Gautam
2015-01-01
This paper discusses Multi-Feature Hierarchical Sequential Pattern Mining, MFH-SPAM, a novel algorithm that efficiently extracts patterns from students' learning activity sequences. This algorithm extends an existing sequential pattern mining algorithm by dynamically selecting the level of specificity for hierarchically-defined features…
Wound repair in rat urinary bladder following electrocautery or holmium laser incision
NASA Astrophysics Data System (ADS)
Venzi, Giordano; Schmidlin, Franz R.; Gabbiani, Giulio; Delacretaz, Guy P.; Pittet, Brigitte; Leisinger, Hans-Juerg; Iselin, Christoph E.
1999-06-01
Woundhealing is a complex phenomenon which varies according the type of tissue but is also depending from the type of tissue injury. Electrocautery mainly induces coagulation necrosis while thermal damages induced by the Holmium laser primarily lead to tissue vaporization which may induce less tissue injury. The aim of this study was to evaluate the healing process of the Holmium laser induced lesions compared to electrocautery induced lesions in urothelial tissue by assessing the inflammatory response and myofibroblast behavior in sequential healing phases. A surgical wound was created in the urinary rat bladder of 32 rats either by electrocautery or by laser (N=16). The inflammatory response, the total lesion depth and the myofibroblast activity during woundhealing was then analyzed on a qualitative basis on days 0/2/4/8. The overall inflammatory response was comparable in both groups up to days two and four. However, at day eight less cellular inflammatory reaction and less myofibroblast activity was found in the specimen of lesions created by the Holmium laser. These results suggest that wound repair may be a less invasive process after Holmium laser than electrocautery.
Hybrid helical magnetic microrobots obtained by 3D template-assisted electrodeposition.
Zeeshan, Muhammad A; Grisch, Roman; Pellicer, Eva; Sivaraman, Kartik M; Peyer, Kathrin E; Sort, Jordi; Özkale, Berna; Sakar, Mahmut S; Nelson, Bradley J; Pané, Salvador
2014-04-09
Hybrid helical magnetic microrobots are achieved by sequential electrodeposition of a CoNi alloy and PPy inside a photoresist template patterned by 3D laser lithography. A controlled actuation of the microrobots by a rotating magnetic field is demonstrated in a fluidic environment. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development of Cranial Bone Surrogate Structures Using Stereolithographic Additive Manufacturing
2017-09-29
shown in Fig. 5. With each cycle, a blade is passed across the platform to create a uniform layer of resin. The resin layer is exposed to a UV laser...due to the direction in which the layers are deposited. In both cases, the sequential layers run parallel to the loading direction of the tensile
NASA Astrophysics Data System (ADS)
Kim, Charlton C.; Wallace, Vincent P.; Coleno, Mariah L.; Dao, Xavier; Tromberg, Bruce J.; Wong, Brian J.
2000-04-01
Laser irradiation of hyaline cartilage result in stable shape changes due to temperature dependent stress relaxation. In this study, we determined the structural changes in chondrocytes within rabbit nasal septal cartilage tissue over a 12-day period using a two-photon laser scanning microscope (TPM) following Nd:YAG laser irradiation. During laser irradiation surface temperature, stress relaxation, and diffuse reflectance, were measured dynamically. Each specimen received one or two sequential laser exposures. The cartilage reached a peak surface temperature of about 61 degrees C during irradiation. Cartilage denatured in 50 percent EtOH was used as a positive control. TPM was performed to detect the fluorescence emission from the chondrocytes. Images of chondrocytes were obtained at depths up to 150 microns, immediately following laser exposure, and also following 12 days in culture. Few differences in the pattern or intensity of fluorescence was observed between controls and irradiated specimens imaged immediately following exposure, regardless of the number of laser pulses. However, following twelve days in tissue culture, the irradiated specimens increase, whereas the native tissue diminishes, in intensity and distribution of fluorescence in the cytoplasm. In contrast, the positive control shows only extracellular matrices and empty lacuna, feature consistent with cell membrane lysis.
11-kW direct diode laser system with homogenized 55 × 20 mm2 Top-Hat intensity distribution
NASA Astrophysics Data System (ADS)
Köhler, Bernd; Noeske, Axel; Kindervater, Tobias; Wessollek, Armin; Brand, Thomas; Biesenbach, Jens
2007-02-01
In comparison with other laser systems diode lasers are characterized by a unique overall efficiency, a small footprint and high reliability. However, one major drawback of direct diode laser systems is the inhomogeneous intensity distribution in the far field. Furthermore the output power of current commercially available systems is limited to about 6 kW. We report on a diode laser system with 11 kW output power at a single wavelength of 940 nm aiming for customer specific large area treatment. To the best of our knowledge this is the highest output power reported so far for a direct diode laser system. In addition to the high output power the intensity distribution of the laser beam is homogenized in both axes leading to a 55 x 20 mm2 Top-Hat intensity profile at a working distance of 400 mm. Homogeneity of the intensity distribution is better than 90%. The intensity in the focal plane is 1 kW/cm2. We will present a detailed characterization of the laser system, including measurements of power, power stability and intensity distribution of the homogenized laser beam. In addition we will compare the experimental data with the results of non-sequential raytracing simulations.
A fast and accurate online sequential learning algorithm for feedforward networks.
Liang, Nan-Ying; Huang, Guang-Bin; Saratchandran, P; Sundararajan, N
2006-11-01
In this paper, we develop an online sequential learning algorithm for single hidden layer feedforward networks (SLFNs) with additive or radial basis function (RBF) hidden nodes in a unified framework. The algorithm is referred to as online sequential extreme learning machine (OS-ELM) and can learn data one-by-one or chunk-by-chunk (a block of data) with fixed or varying chunk size. The activation functions for additive nodes in OS-ELM can be any bounded nonconstant piecewise continuous functions and the activation functions for RBF nodes can be any integrable piecewise continuous functions. In OS-ELM, the parameters of hidden nodes (the input weights and biases of additive nodes or the centers and impact factors of RBF nodes) are randomly selected and the output weights are analytically determined based on the sequentially arriving data. The algorithm uses the ideas of ELM of Huang et al. developed for batch learning which has been shown to be extremely fast with generalization performance better than other batch training methods. Apart from selecting the number of hidden nodes, no other control parameters have to be manually chosen. Detailed performance comparison of OS-ELM is done with other popular sequential learning algorithms on benchmark problems drawn from the regression, classification and time series prediction areas. The results show that the OS-ELM is faster than the other sequential algorithms and produces better generalization performance.
Robotic Laser Coating Removal System
2008-08-01
9 3.2 SELECTION OF TEST PLATFORM/FACILITY .................................. 9 3.3 TEST PLATFORM/FACILITY HISTORY...lasers are 4 efficient in converting electrical energy to coherent radiation and, thus, have widespread industrial use. In order to select an...completion of this evaluation a 6 kW CO2 laser from Rofin-Sinar was selected for use in the RLCRS. This laser provided the highest quality laser
Determining the 3-D structure and motion of objects using a scanning laser range sensor
NASA Technical Reports Server (NTRS)
Nandhakumar, N.; Smith, Philip W.
1993-01-01
In order for the EVAHR robot to autonomously track and grasp objects, its vision system must be able to determine the 3-D structure and motion of an object from a sequence of sensory images. This task is accomplished by the use of a laser radar range sensor which provides dense range maps of the scene. Unfortunately, the currently available laser radar range cameras use a sequential scanning approach which complicates image analysis. Although many algorithms have been developed for recognizing objects from range images, none are suited for use with single beam, scanning, time-of-flight sensors because all previous algorithms assume instantaneous acquisition of the entire image. This assumption is invalid since the EVAHR robot is equipped with a sequential scanning laser range sensor. If an object is moving while being imaged by the device, the apparent structure of the object can be significantly distorted due to the significant non-zero delay time between sampling each image pixel. If an estimate of the motion of the object can be determined, this distortion can be eliminated; but, this leads to the motion-structure paradox - most existing algorithms for 3-D motion estimation use the structure of objects to parameterize their motions. The goal of this research is to design a rigid-body motion recovery technique which overcomes this limitation. The method being developed is an iterative, linear, feature-based approach which uses the non-zero image acquisition time constraint to accurately recover the motion parameters from the distorted structure of the 3-D range maps. Once the motion parameters are determined, the structural distortion in the range images is corrected.
Laser versus scalpel cleaning of crustose lichens on granite
NASA Astrophysics Data System (ADS)
Rivas, T.; Pozo-Antonio, J. S.; López de Silanes, M. E.; Ramil, A.; López, A. J.
2018-05-01
This paper addresses the evaluation of the cleaning of crustose lichens developing on granite. The evaluation was performed considering the effectiveness of the cleanings and harmfulness exerted on the granite. The laser cleaning of lichen was compared with the most conventional procedure, scalpel. The combination of both procedures was also tested. The study, which was carried out with two different species of crustose lichen, was also focused on the influence of the intrinsic characteristics of the lichen on the effectiveness. The cleanings were evaluated by optic and electronic microscopies, FTIR and colour spectrophotometry. A previous characterization of the lichen and its interaction with the granite using those analytical techniques were also performed. The laser cleaning effectiveness depends on the coverage and the colour of the lichen; also, the prior mechanical weakening of the lichen by scalpel seemed to improve the laser cleaning. The darkest lichen was satisfactorily removed by laser and with the combined cleaning. Conversely, the lightest lichen was more difficult to extract with laser than the darkest lichen, being necessary to apply both methods sequentially. Despite laser and the combination of methods cleaned satisfactorily the surface, they were unable to eliminate the thalli into fissures.
[System continuity and energy distribution in laser-induced thermo therapy (LITT)].
Pech, M; Werk, M; Beck, A; Stohlmann, A; Ricke, J
2002-06-01
Evaluation of the continuity and energy distribution of a laser system for laser-induced thermo therapy. For evaluation of the continuity of laser optical devices, laser generating units and optical fibers of three different manufactures (Dornier, Hüttinger, Somatex), we used the equipment to generate a laser beam of 25 Watt for 60 minutes. Measurements of the applied energy were done sequentially with two MY Test (Fa. Hüttinger) units. We also performed two in vitro ablations of animal liver tissue with different fiber optics [Mikrodom A 13-0540, Microflexx REF A 13-0561 (Hüttinger), Diffusor-Tip H-6111-T 3, Diffusor H-6111-T 4 (Dornier), Somaflex-Diffusor (Somatex)] over 20 minutes at- an energy flow of 25 J per second. We then evaluated the geometry of coagulation. The different equipment used for our tests showed differences of a maximum of 10 %. Some components did not work properly in certain configurations even though the manufacturer assured it would. We saw significant differences in the ablation characteristics of the different fiber optics, especially in axial and frontal directions. Knowledge of the different characteristics in energy distribution and ablation characteristics are an important factor in performing a successful laser-induced thermo therapy.
Airborne Laser Polar Nephelometer
NASA Technical Reports Server (NTRS)
Grams, Gerald W.
1973-01-01
A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.
Yu, Zhan; Li, Yuanyang; Liu, Lisheng; Guo, Jin; Wang, Tingfeng; Yang, Guoqing
2017-11-10
The speckle pattern (line by line) sequential extraction (SPSE) metric is proposed by the one-dimensional speckle intensity level crossing theory. Through the sequential extraction of received speckle information, the speckle metrics for estimating the variation of focusing spot size on a remote diffuse target are obtained. Based on the simulation, we will give some discussions about the SPSE metric range of application under the theoretical conditions, and the aperture size will affect the metric performance of the observation system. The results of the analyses are verified by the experiment. This method is applied to the detection of relative static target (speckled jitter frequency is less than the CCD sampling frequency). The SPSE metric can determine the variation of the focusing spot size over a long distance, moreover, the metric will estimate the spot size under some conditions. Therefore, the monitoring and the feedback of far-field spot will be implemented laser focusing system applications and help the system to optimize the focusing performance.
NASA Technical Reports Server (NTRS)
Sidik, S. M.
1972-01-01
A sequential adaptive experimental design procedure for a related problem is studied. It is assumed that a finite set of potential linear models relating certain controlled variables to an observed variable is postulated, and that exactly one of these models is correct. The problem is to sequentially design most informative experiments so that the correct model equation can be determined with as little experimentation as possible. Discussion includes: structure of the linear models; prerequisite distribution theory; entropy functions and the Kullback-Leibler information function; the sequential decision procedure; and computer simulation results. An example of application is given.
Rossitto, Giacomo; Battistel, Michele; Barbiero, Giulio; Bisogni, Valeria; Maiolino, Giuseppe; Diego, Miotto; Seccia, Teresa M; Rossi, Gian Paolo
2018-02-01
The pulsatile secretion of adrenocortical hormones and a stress reaction occurring when starting adrenal vein sampling (AVS) can affect the selectivity and also the assessment of lateralization when sequential blood sampling is used. We therefore tested the hypothesis that a simulated sequential blood sampling could decrease the diagnostic accuracy of lateralization index for identification of aldosterone-producing adenoma (APA), as compared with bilaterally simultaneous AVS. In 138 consecutive patients who underwent subtyping of primary aldosteronism, we compared the results obtained simultaneously bilaterally when starting AVS (t-15) and 15 min after (t0), with those gained with a simulated sequential right-to-left AVS technique (R ⇒ L) created by combining hormonal values obtained at t-15 and at t0. The concordance between simultaneously obtained values at t-15 and t0, and between simultaneously obtained values and values gained with a sequential R ⇒ L technique, was also assessed. We found a marked interindividual variability of lateralization index values in the patients with bilaterally selective AVS at both time point. However, overall the lateralization index simultaneously determined at t0 provided a more accurate identification of APA than the simulated sequential lateralization indexR ⇒ L (P = 0.001). Moreover, regardless of which side was sampled first, the sequential AVS technique induced a sequence-dependent overestimation of lateralization index. While in APA patients the concordance between simultaneous AVS at t0 and t-15 and between simultaneous t0 and sequential technique was moderate-to-good (K = 0.55 and 0.66, respectively), in non-APA patients, it was poor (K = 0.12 and 0.13, respectively). Sequential AVS generates factitious between-sides gradients, which lower its diagnostic accuracy, likely because of the stress reaction arising upon starting AVS.
Laser-induced selective copper plating of polypropylene surface
NASA Astrophysics Data System (ADS)
Ratautas, K.; Gedvilas, M.; Stankevičiene, I.; JagminienÄ--, A.; Norkus, E.; Li Pira, N.; Sinopoli, S.; Emanuele, U.; Račiukaitis, G.
2016-03-01
Laser writing for selective plating of electro-conductive lines for electronics has several significant advantages, compared to conventional printed circuit board technology. Firstly, this method is faster and cheaper at the prototyping stage. Secondly, material consumption is reduced, because it works selectively. However, the biggest merit of this method is potentiality to produce moulded interconnect device, enabling to create electronics on complex 3D surfaces, thus saving space, materials and cost of production. There are two basic techniques of laser writing for selective plating on plastics: the laser-induced selective activation (LISA) and laser direct structuring (LDS). In the LISA method, pure plastics without any dopant (filler) can be used. In the LDS method, special fillers are mixed in the polymer matrix. These fillers are activated during laser writing process, and, in the next processing step, the laser modified area can be selectively plated with metals. In this work, both methods of the laser writing for the selective plating of polymers were investigated and compared. For LDS approach, new material: polypropylene with carbon-based additives was tested using picosecond and nanosecond laser pulses. Different laser processing parameters (laser pulse energy, scanning speed, the number of scans, pulse durations, wavelength and overlapping of scanned lines) were applied in order to find out the optimal regime of activation. Areal selectivity tests showed a high plating resolution. The narrowest width of a copper-plated line was less than 23 μm. Finally, our material was applied to the prototype of the electronic circuit board on a 2D surface.
Fang, Yuyu; Li, Caixia; Wu, Lei; Bai, Bing; Li, Xing; Jia, Yiming; Feng, Wen; Yuan, Lihua
2015-09-07
A novel non-symmetric pillar[5]arene bearing triazole-linked 8-oxyquinolines at one rim was synthesized and demonstrated as a sequential fluorescence sensor for thorium(iv) followed by fluoride ions with high sensitivity and selectivity.
The Nature of Phonological Encoding During Spoken Word Retrieval.
ERIC Educational Resources Information Center
Sullivan, Michael P.; Riffel, Brian
1999-01-01
Examined whether phonological selection occurs sequentially or in parallel. College students named picture primes and targets, with varied response stimulus intervals between primes and targets. Results were consistent with Dell's (1988) two-stage sequential model of encoding, which shows an initial parallel activation within a lexical network…
Discrimination between sequential and simultaneous virtual channels with electrical hearing
Landsberger, David; Galvin, John J.
2011-01-01
In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects’ discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation. PMID:21895094
Discrimination between sequential and simultaneous virtual channels with electrical hearing.
Landsberger, David; Galvin, John J
2011-09-01
In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects' discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation. © 2011 Acoustical Society of America
NASA Technical Reports Server (NTRS)
Bathel, Brett F.; Danehy, Paul M.; Inman, Jennifer A.; Jones, Stephen B.; Ivey,Christopher b.; Goyne, Christopher P.
2010-01-01
Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to perform velocity measurements in hypersonic flows by generating multiple tagged lines which fluoresce as they convect downstream. For each laser pulse, a single interline, progressive scan intensified CCD (charge-coupled device) camera was used to obtain two sequential images of the NO molecules that had been tagged by the laser. The CCD configuration allowed for sub-microsecond acquisition of both images, resulting in sub-microsecond temporal resolution as well as sub-mm spatial resolution (0.5-mm horizontal, 0.7-mm vertical). Determination of axial velocity was made by application of a cross-correlation analysis of the horizontal shift of individual tagged lines. A numerical study of measured velocity error due to a uniform and linearly-varying collisional rate distribution was performed. Quantification of systematic errors, the contribution of gating/exposure duration errors, and the influence of collision rate on temporal uncertainty were made. Quantification of the spatial uncertainty depended upon the signal-to-noise ratio of the acquired profiles. This velocity measurement technique has been demonstrated for two hypersonic flow experiments: (1) a reaction control system (RCS) jet on an Orion Crew Exploration Vehicle (CEV) wind tunnel model and (2) a 10-degree half-angle wedge containing a 2-mm tall, 4-mm wide cylindrical boundary layer trip. The experiments were performed at the NASA Langley Research Center's 31-Inch Mach 10 Air Tunnel.
Takahashi, Mei; Ito, Arisa; Kajihara, Takuro; Matsuo, Hiroki; Arai, Tsunenori
2010-01-01
The purpose of this study is to investigate transient process of the charring at the laser catheter-tip in blood during therapeutic laser irradiation by the back scattering light measurement to detect precursor state of the charring. We took account of using photodynamic therapy for arrhythmia in blood through the laser catheter. We observed the influence of the red laser irradiation (λ=663 nm) upon the shape of red blood cells (RBCs). The RBCs aggregation, round formation, and hemolysis were took place sequentially before charring. With a model blood sandwiched between glass plates simulated as a catheter-tip boundary, we measured diffuse-reflected-light power and transmitted-light power simultaneously and continuously by a microscopic optics during the laser irradiation. We found that measured light power changes were originated with RBCs shape change induced by temperature rise due to the laser irradiation. A gentle peak following a slow descending was observed in the diffuse-reflected-light power history. This history might indicate the precursor state of the charring, in which the hemolysis might be considered to advance rapidly. We think that the measurement of diffuse-reflected-light power history might be able to detect precursor state of charring at the catheter-tip in blood.
Selective Emitter Pumped Rare Earth Laser
NASA Technical Reports Server (NTRS)
Chubb, Donald L. (Inventor); Patton, Martin O. (Inventor)
2001-01-01
A selective emitter pumped rare earth laser provides an additional type of laser for use in many laser applications. Rare earth doped lasers exist which are pumped with flashtubes or laser diodes. The invention uses a rare earth emitter to transform thermal energy input to a spectral band matching the absorption band of a rare earth in the laser in order to produce lasing.
Yoda, Satoshi; Lin, Jessica J; Lawrence, Michael S; Burke, Benjamin J; Friboulet, Luc; Langenbucher, Adam; Dardaei, Leila; Prutisto-Chang, Kylie; Dagogo-Jack, Ibiayi; Timofeevski, Sergei; Hubbeling, Harper; Gainor, Justin F; Ferris, Lorin A; Riley, Amanda K; Kattermann, Krystina E; Timonina, Daria; Heist, Rebecca S; Iafrate, A John; Benes, Cyril H; Lennerz, Jochen K; Mino-Kenudson, Mari; Engelman, Jeffrey A; Johnson, Ted W; Hata, Aaron N; Shaw, Alice T
2018-06-01
The cornerstone of treatment for advanced ALK-positive lung cancer is sequential therapy with increasingly potent and selective ALK inhibitors. The third-generation ALK inhibitor lorlatinib has demonstrated clinical activity in patients who failed previous ALK inhibitors. To define the spectrum of ALK mutations that confer lorlatinib resistance, we performed accelerated mutagenesis screening of Ba/F3 cells expressing EML4-ALK. Under comparable conditions, N -ethyl- N -nitrosourea (ENU) mutagenesis generated numerous crizotinib-resistant but no lorlatinib-resistant clones harboring single ALK mutations. In similar screens with EML4-ALK containing single ALK resistance mutations, numerous lorlatinib-resistant clones emerged harboring compound ALK mutations. To determine the clinical relevance of these mutations, we analyzed repeat biopsies from lorlatinib-resistant patients. Seven of 20 samples (35%) harbored compound ALK mutations, including two identified in the ENU screen. Whole-exome sequencing in three cases confirmed the stepwise accumulation of ALK mutations during sequential treatment. These results suggest that sequential ALK inhibitors can foster the emergence of compound ALK mutations, identification of which is critical to informing drug design and developing effective therapeutic strategies. Significance: Treatment with sequential first-, second-, and third-generation ALK inhibitors can select for compound ALK mutations that confer high-level resistance to ALK-targeted therapies. A more efficacious long-term strategy may be up-front treatment with a third-generation ALK inhibitor to prevent the emergence of on-target resistance. Cancer Discov; 8(6); 714-29. ©2018 AACR. This article is highlighted in the In This Issue feature, p. 663 . ©2018 American Association for Cancer Research.
Autonomous Legged Hill and Stairwell Ascent
2011-11-01
environments with little burden to a human operator. Keywords: autonomous robot , hill climbing , stair climbing , sequential composition, hexapod, self...X-RHex robot on a set of stairs with laser scanner, IMU, wireless repeater, and handle payloads. making them useful for both climbing hills and...reconciliation into that more powerful (but restrictive) framework. 1) The Stair Climbing Behavior: RHex robots have been climbing single-flight stairs
Herklotz, A.; Dörr, Kathrin; Ward, T. Z.; ...
2015-04-03
In this paper, to have precise atomic layer control over interfaces, we examine the growth of complex oxides through the sequential deposition from binary targets by pulsed laser deposition. In situ reflection high-energy electron diffraction (RHEED) is used to control the growth and achieve films with excellent structural quality. The growth from binary oxide targets is fundamentally different from single target growth modes and shows more similarities to shuttered growth by molecular beam epitaxy. The RHEED intensity oscillations of non-stoichiometric growth are consistent with a model of island growth and accumulation of excess material on the surface that can bemore » utilized to determine the correct stoichiometry for growth. Correct monolayer doses can be determined through an envelope frequency in the RHEED intensity oscillations. In order to demonstrate the ability of this growth technique to create complex heterostructures, the artificial n = 2 and 3 Sr n +1Ti n O 3 n +1 Ruddlesden-Popper phases are grown with good long-range order. Finally, this method enables the precise unit-cell level control over the structure of perovskite-type oxides, and thus the growth of complex materials with improved structural quality and electronic functionality.« less
Herklotz, Andreas; Dorr, Kathrin; Ward, Thomas Zac; ...
2015-04-03
To have precise atomic layer control over interfaces, we examine the growth of complex oxides through the sequential deposition from binary targets by pulsed laser deposition. In situ reflection high-energy electron diffraction (RHEED) is used to control the growth and achieve films with excellent structural quality. The growth from binary oxide targets is fundamentally different from single target growth modes and shows more similarities to shuttered growth by molecular beam epitaxy. The RHEED intensity oscillations of non-stoichiometric growth are consistent with a model of island growth and accumulation of excess material on the surface that can be utilized to determinemore » the correct stoichiometry for growth. Correct monolayer doses can be determined through an envelope frequency in the RHEED intensity oscillations. In order to demonstrate the ability of this growth technique to create complex heterostructures, the artificial n = 2 and 3 Sr n+1Ti nO 3 n+1 Ruddlesden-Popper phases are grown with good long-range order. Furthermore, this method enables the precise unit-cell level control over the structure of perovskite-type oxides, and thus the growth of complex materials with improved structural quality and electronic functionality.« less
NASA Technical Reports Server (NTRS)
Miranda, F. A.; Gordon, W. L.; Bhasin, K. B.; Heinen, V. O.; Warner, J. D.; Valco, G. J.
1989-01-01
Millimeter wave transmission measurements through YBa2Cu3O(7-delta) thin films on MgO, ZrO2 and LaAlO3 substrates, are reported. The films (approx. 1 micron) were deposited by sequential evaporation and laser ablation techniques. Transition temperatures T sub c, ranging from 89.7 K for the Laser Ablated film on LaAlO3 to approximately 72 K for the sequentially evaporated film on MgO, were obtained. The values of the real and imaginary parts of the complex conductivity, sigma 1 and sigma 2, are obtained from the transmission data, assuming a two fluid model. The BCS approach is used to calculate values for an effective energy gap from the obtained values of sigma sub 1. A range of gap values from 2 DELTA o/K sub B T sub c = 4.19 to 4.35 was obtained. The magnetic penetration depth is evaluated from the deduced values of sigma 2. These results are discussed together with the frequency dependence of the normalized transmission amplitude, P/P sub c, below and above T sub c.
de Paula, Lauro C. M.; Soares, Anderson S.; de Lima, Telma W.; Delbem, Alexandre C. B.; Coelho, Clarimar J.; Filho, Arlindo R. G.
2014-01-01
Several variable selection algorithms in multivariate calibration can be accelerated using Graphics Processing Units (GPU). Among these algorithms, the Firefly Algorithm (FA) is a recent proposed metaheuristic that may be used for variable selection. This paper presents a GPU-based FA (FA-MLR) with multiobjective formulation for variable selection in multivariate calibration problems and compares it with some traditional sequential algorithms in the literature. The advantage of the proposed implementation is demonstrated in an example involving a relatively large number of variables. The results showed that the FA-MLR, in comparison with the traditional algorithms is a more suitable choice and a relevant contribution for the variable selection problem. Additionally, the results also demonstrated that the FA-MLR performed in a GPU can be five times faster than its sequential implementation. PMID:25493625
de Paula, Lauro C M; Soares, Anderson S; de Lima, Telma W; Delbem, Alexandre C B; Coelho, Clarimar J; Filho, Arlindo R G
2014-01-01
Several variable selection algorithms in multivariate calibration can be accelerated using Graphics Processing Units (GPU). Among these algorithms, the Firefly Algorithm (FA) is a recent proposed metaheuristic that may be used for variable selection. This paper presents a GPU-based FA (FA-MLR) with multiobjective formulation for variable selection in multivariate calibration problems and compares it with some traditional sequential algorithms in the literature. The advantage of the proposed implementation is demonstrated in an example involving a relatively large number of variables. The results showed that the FA-MLR, in comparison with the traditional algorithms is a more suitable choice and a relevant contribution for the variable selection problem. Additionally, the results also demonstrated that the FA-MLR performed in a GPU can be five times faster than its sequential implementation.
Jaworski, Piotr; Nikodem, Michał
2018-01-01
In this paper, we present a system for sequential detection of multiple gases using laser-based wavelength modulation spectroscopy (WMS) method combined with a Herriot-type multi-pass cell. Concentration of hydrogen sulfide (H2S), methane (CH4), carbon dioxide (CO2), and ammonia (NH3) are retrieved using three distributed feedback laser diodes operating at 1574.5 nm (H2S and CO2), 1651 nm (CH4), and 1531 nm (NH3). Careful adjustment of system parameters allows for H2S sensing at single parts-per-million by volume (ppmv) level with strongly reduced interference from adjacent CO2 transitions even at atmospheric pressure. System characterization in laboratory conditions is presented and the results from initial tests in real-world application are demonstrated. PMID:29425175
Observing conformations of single FoF1-ATP synthases in a fast anti-Brownian electrokinetic trap
NASA Astrophysics Data System (ADS)
Su, Bertram; Düser, Monika G.; Zarrabi, Nawid; Heitkamp, Thomas; Starke, Ilka; Börsch, Michael
2015-03-01
To monitor conformational changes of individual membrane transporters in liposomes in real time, we attach two fluorophores to selected domains of a protein. Sequential distance changes between the dyes are recorded and analyzed by Förster resonance energy transfer (FRET). Using freely diffusing membrane proteins reconstituted in liposomes, observation times are limited by Brownian motion through the confocal detection volume. A. E. Cohen and W. E. Moerner have invented and built microfluidic devices to actively counteract Brownian motion of single nanoparticles in electrokinetic traps (ABELtrap). Here we present a version of an ABELtrap with a laser focus pattern generated by electro-optical beam deflectors and controlled by a programmable FPGA. This ABELtrap could hold single fluorescent nanobeads for more than 100 seconds, increasing the observation times of a single particle more than 1000-fold. Conformational changes of single FRET-labeled membrane enzymes FoF1-ATP synthase can be detected in the ABELtrap.
Building a Lego wall: Sequential action selection.
Arnold, Amy; Wing, Alan M; Rotshtein, Pia
2017-05-01
The present study draws together two distinct lines of enquiry into the selection and control of sequential action: motor sequence production and action selection in everyday tasks. Participants were asked to build 2 different Lego walls. The walls were designed to have hierarchical structures with shared and dissociated colors and spatial components. Participants built 1 wall at a time, under low and high load cognitive states. Selection times for correctly completed trials were measured using 3-dimensional motion tracking. The paradigm enabled precise measurement of the timing of actions, while using real objects to create an end product. The experiment demonstrated that action selection was slowed at decision boundary points, relative to boundaries where no between-wall decision was required. Decision points also affected selection time prior to the actual selection window. Dual-task conditions increased selection errors. Errors mostly occurred at boundaries between chunks and especially when these required decisions. The data support hierarchical control of sequenced behavior. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Cost-effectiveness of simultaneous versus sequential surgery in head and neck reconstruction.
Wong, Kevin K; Enepekides, Danny J; Higgins, Kevin M
2011-02-01
To determine whether simultaneous (ablation and reconstruction overlaps by two teams) head and neck reconstruction is cost effective compared to sequentially (ablation followed by reconstruction) performed surgery. Case-controlled study. Tertiary care hospital. Oncology patients undergoing free flap reconstruction of the head and neck. A match paired comparison study was performed with a retrospective chart review examining the total time of surgery for sequential and simultaneous surgery. Nine patients were selected for both the sequential and simultaneous groups. Sequential head and neck reconstruction patients were pair matched with patients who had undergone similar oncologic ablative or reconstructive procedures performed in a simultaneous fashion. A detailed cost analysis using the microcosting method was then undertaken looking at the direct costs of the surgeons, anesthesiologist, operating room, and nursing. On average, simultaneous surgery required 3 hours 15 minutes less operating time, leading to a cost savings of approximately $1200/case when compared to sequential surgery. This represents approximately a 15% reduction in the cost of the entire operation. Simultaneous head and neck reconstruction is more cost effective when compared to sequential surgery.
Michael, James B.; Venkateswaran, Prabhakar; Shaddix, Christopher R.; ...
2015-04-08
Planar laser-induced incandescence (LII) imaging is reported at repetition rates up to 100 kHz using a burst-mode laser system to enable studies of soot formation dynamics in highly turbulent flames. Furthermore, to quantify the accuracy and uncertainty of relative soot volume fraction measurements, the temporal evolution of the LII field in laminar and turbulent flames is examined at various laser operating conditions. Under high-speed repetitive probing, it is found that LII signals are sensitive to changes in soot physical characteristics when operating at high laser fluences within the soot vaporization regime. For these laser conditions, strong planar LII signals aremore » observed at measurement rates up to 100 kHz but are primarily useful for qualitative tracking of soot structure dynamics. However, LII signals collected at lower fluences allow sequential planar measurements of the relative soot volume fraction with a sufficient signal-to-noise ratio at repetition rates of 10–50 kHz. Finally, guidelines for identifying and avoiding the onset of repetitive probe effects in the LII signals are discussed, along with other potential sources of measurement error and uncertainty.« less
Risk-aware multi-armed bandit problem with application to portfolio selection
Huo, Xiaoguang
2017-01-01
Sequential portfolio selection has attracted increasing interest in the machine learning and quantitative finance communities in recent years. As a mathematical framework for reinforcement learning policies, the stochastic multi-armed bandit problem addresses the primary difficulty in sequential decision-making under uncertainty, namely the exploration versus exploitation dilemma, and therefore provides a natural connection to portfolio selection. In this paper, we incorporate risk awareness into the classic multi-armed bandit setting and introduce an algorithm to construct portfolio. Through filtering assets based on the topological structure of the financial market and combining the optimal multi-armed bandit policy with the minimization of a coherent risk measure, we achieve a balance between risk and return. PMID:29291122
Risk-aware multi-armed bandit problem with application to portfolio selection.
Huo, Xiaoguang; Fu, Feng
2017-11-01
Sequential portfolio selection has attracted increasing interest in the machine learning and quantitative finance communities in recent years. As a mathematical framework for reinforcement learning policies, the stochastic multi-armed bandit problem addresses the primary difficulty in sequential decision-making under uncertainty, namely the exploration versus exploitation dilemma, and therefore provides a natural connection to portfolio selection. In this paper, we incorporate risk awareness into the classic multi-armed bandit setting and introduce an algorithm to construct portfolio. Through filtering assets based on the topological structure of the financial market and combining the optimal multi-armed bandit policy with the minimization of a coherent risk measure, we achieve a balance between risk and return.
Next Generation Driver for Attosecond and Laser-plasma Physics.
Rivas, D E; Borot, A; Cardenas, D E; Marcus, G; Gu, X; Herrmann, D; Xu, J; Tan, J; Kormin, D; Ma, G; Dallari, W; Tsakiris, G D; Földes, I B; Chou, S-W; Weidman, M; Bergues, B; Wittmann, T; Schröder, H; Tzallas, P; Charalambidis, D; Razskazovskaya, O; Pervak, V; Krausz, F; Veisz, L
2017-07-12
The observation and manipulation of electron dynamics in matter call for attosecond light pulses, routinely available from high-order harmonic generation driven by few-femtosecond lasers. However, the energy limitation of these lasers supports only weak sources and correspondingly linear attosecond studies. Here we report on an optical parametric synthesizer designed for nonlinear attosecond optics and relativistic laser-plasma physics. This synthesizer uniquely combines ultra-relativistic focused intensities of about 10 20 W/cm 2 with a pulse duration of sub-two carrier-wave cycles. The coherent combination of two sequentially amplified and complementary spectral ranges yields sub-5-fs pulses with multi-TW peak power. The application of this source allows the generation of a broad spectral continuum at 100-eV photon energy in gases as well as high-order harmonics in relativistic plasmas. Unprecedented spatio-temporal confinement of light now permits the investigation of electric-field-driven electron phenomena in the relativistic regime and ultimately the rise of next-generation intense isolated attosecond sources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spallicci, Alessandro D. A. M., E-mail: spallicci@cnrs-orleans.fr
2013-02-20
Gravitational waves coming from supermassive black hole binaries (SMBHBs) are targeted by both the Pulsar Timing Array (PTA) and Space Laser Interferometry (SLI). The possibility of a single SMBHB being tracked first by PTA, through inspiral, and later by SLI, up to merger and ring-down, has been previously suggested. Although the bounding parameters are drawn by the current PTA or the upcoming Square Kilometer Array (SKA), and by the New Gravitational Observatory (NGO), derived from the Laser Interferometer Space Antenna (LISA), this paper also addresses sequential detection beyond specific project constraints. We consider PTA-SKA, which is sensitive from 10{sup -9}more » to p Multiplication-Sign 10{sup -7} Hz (p = 4, 8), and SLI, which operates from s Multiplication-Sign 10{sup -5} up to 1 Hz (s = 1, 3). An SMBHB in the range of 2 Multiplication-Sign 10{sup 8}-2 Multiplication-Sign 10{sup 9} M {sub Sun} (the masses are normalized to a (1 + z) factor, the redshift lying between z = 0.2 and z = 1.5) moves from the PTA-SKA to the SLI band over a period ranging from two months to fifty years. By combining three supermassive black hole (SMBH)-host relations with three accretion prescriptions, nine astrophysical scenarios are formed. They are then related to three levels of pulsar timing residuals (50, 5, 1 ns), generating 27 cases. For residuals of 1 ns, sequential detection probability will never be better than 4.7 Multiplication-Sign 10{sup -4} yr{sup -2} or 3.3 Multiplication-Sign 10{sup -6} yr{sup -2} (per year to merger and per year of survey), according to the best and worst astrophysical scenarios, respectively; put differently this means one sequential detection every 46 or 550 years for an equivalent maximum time to merger and duration of the survey. The chances of sequential detection are further reduced by increasing values of the s parameter (they vanish for s = 10) and of the SLI noise, and by decreasing values of the remnant spin. The spread in the predictions diminishes when timing precision is improved or the SLI low-frequency cutoff is lowered. So while transit times and the SLI signal-to-noise ratio (S/N) may be adequate, the likelihood of sequential detection is severely hampered by the current estimates on the number-just a handful-of individual inspirals observable by PTA-SKA, and to a lesser extent by the wide gap between the pulsar timing and space interferometry bands, and by the severe requirements on pulsar timing residuals. Optimization of future operational scenarios for SKA and SLI is briefly dealt with, since a detection of even a single event would be of paramount importance for the understanding of SMBHBs and of the astrophysical processes connected to their formation and evolution.« less
ERIC Educational Resources Information Center
Raymond, Chase Wesley
2014-01-01
This dissertation takes an ethnomethodologically-grounded, conversation-analytic approach in investigating the sequential deployment of linguistic resources in Spanish-language talk-in-interaction. Three sets of resources are examined: 2nd-person singular reference forms (tú, vos, usted), indicative/subjunctive verbal mood selection, and…
Evaluating Bias of Sequential Mixed-Mode Designs against Benchmark Surveys
ERIC Educational Resources Information Center
Klausch, Thomas; Schouten, Barry; Hox, Joop J.
2017-01-01
This study evaluated three types of bias--total, measurement, and selection bias (SB)--in three sequential mixed-mode designs of the Dutch Crime Victimization Survey: telephone, mail, and web, where nonrespondents were followed up face-to-face (F2F). In the absence of true scores, all biases were estimated as mode effects against two different…
Method and apparatus for aligning a solar concentrator using two lasers
Diver Jr., Richard Boyer
2003-07-22
A method and apparatus are provided for aligning the facets of a solar concentrator. A first laser directs a first laser beam onto a selected facet of the concentrator such that a target board positioned adjacent to the first laser at approximately one focal length behind the focal point of the concentrator is illuminated by the beam after reflection thereof off of the selected facet. A second laser, located adjacent to the vertex of the optical axis of the concentrator, is used to direct a second laser beam onto the target board at a target point thereon. By adjusting the selected facet to cause the first beam to illuminate the target point on the target board produced by the second beam, the selected facet can be brought into alignment with the target point. These steps are repeated for other selected facets of the concentrator, as necessary, to provide overall alignment of the concentrator.
Sequential solvent extraction for forms of antimony in five selected coals
Qi, C.; Liu, Gaisheng; Kong, Y.; Chou, C.-L.; Wang, R.
2008-01-01
Abundance of antimony in bulk samples has been determined in five selected coals, three coals from Huaibei Coalfield, Anhui, China, and two from the Illinois Basin in the United States. The Sb abundance in these samples is in the range of 0.11-0.43 ??g/g. The forms of Sb in coals were studied by sequential solvent extraction. The six forms of Sb are water soluble, ion changeable, organic matter bound, carbonate bound, silicate bound, and sulfide bound. Results of sequential extraction show that silicate-bound Sb is the most abundant form in these coals. Silicate- plus sulfide-bound Sb accounts for more than half of the total Sb in all coals. Bituminous coals are higher in organic matterbound Sb than anthracite and natural coke, indicating that the Sb in the organic matter may be incorporated into silicate and sulfide minerals during metamorphism. ?? 2008 by The University of Chicago. All rights reserved.
[Professor GAO Yuchun's experience on "sequential acupuncture leads to smooth movement of qi"].
Wang, Yanjun; Xing, Xiao; Cui, Linhua
2016-01-01
Professor GAO Yuchun is considered as the key successor of GAO's academic school of acupuncture and moxibustion in Yanzhao region. Professor GAO's clinical experience of, "sequential acupuncture" is introduced in details in this article. In Professor GAO's opinions, appropriate acupuncture sequence is the key to satisfactory clinical effects during treatment. Based on different acupoints, sequential acupuncture can achieve the aim of qi following needles and needles leading qi; based on different symptoms, sequential acupuncture can regulate qi movement; based on different body positions, sequential acupuncture can harmonize qi-blood and reinforcing deficiency and reducing excess. In all, according to the differences of disease condition and constitution, based on the accurate acupoint selection and appropriate manipulation, it is essential to capture the nature of diseases and make the order of acupuncture, which can achieve the aim of regulating qi movement and reinforcing deficiency and reducing excess.
Efficient solar-pumped Nd:YAG laser by a double-stage light-guide/V-groove cavity
NASA Astrophysics Data System (ADS)
Almeida, Joana; Liang, Dawei
2011-05-01
Since the first reported Nd:YAG solar laser, researchers have been exploiting parabolic mirrors and heliostats for enhancing laser output performance. We are now investigating the production of an efficient solar-pumped laser for the reduction of magnesium from magnesium oxide, which could be an alternative solution to fossil fuel. Therefore both high conversion efficiency and excellent beam quality are imperative. By using a single fused silica light guide of rectangular cross section, highly concentrated solar radiation at the focal spot of a stationary parabolic mirror is efficiently transferred to a water-flooded V-groove pump cavity. It allows for the double-pass absorption of pump light along a 4mm diameter, 30mm length, 1.1at% Nd:YAG rod. Optimum pumping parameters and solar laser output power are found through ZEMAXTM non-sequential ray-tracing and LASCADTM laser cavity analysis. 11.0 W of multimode laser output power with excellent beam profile is numerically calculated, corresponding to 6.1W/m2 collection efficiency. To validate the proposed pumping scheme, an experimental setup of the double-stage light-guide/V-groove cavity was built. 78% of highly concentrated solar radiation was efficiently transmitted by the fused silica light guide. The proposed pumping scheme can be an effective solution for enhancing solar laser performances when compared to other side-pump configurations.
NASA Astrophysics Data System (ADS)
Chou, Jim-Son; Sumida, David S.; Wittig, C.
1985-02-01
PO (X 2Π) is produced via the collision-free infrared multiple photon dissociation (IRMPD) of volatile organophosphorous molecules, and is detected by two-frequency two-photon ionization, using the B 2Σ+ state to provide a spectral signature from which X 2Π populations are obtained. Sequential dissociations occur during the IR laser photolysis, in which nascent fragments continue to undergo IRMPD, and PO (X 2Π) accrues from a series of bond fission reactions. Nascent vibrational, rotational, and translational excitations are in sensible accord with this mechanism, except for a few rotational states near J=19.5. Unlike the nuclear degrees of freedom, the PO (X 2Π) spin-orbit states are populated quite selectively. The 2Π3/2 state, lying only 224 cm-1 above the 2Π1/2 ground state, contains only ˜11% of the population, compared to 34% for a 300 K sample. This result is unambiguous; it persists with all precursors, laser fluences, etc., and is verified by comparisons to spectra obtained using a microwave discharge, a flame, and when thermalizing nascent excitations with an inert diluent. This result underscores the importance of the separate potential surfaces which correlate to the product spin-orbit states, and the small amount of 2Π3/2 population can be accounted for by nonadiabatic coupling during dissociation, and/or ``freezing'' the amount of S1 character in an excited precursor in which S0 and S1 are coupled nonradiatively. We note that such electronic specificity should be dealt with in the analogous recombination reactions.
Boyde, A; Vesely, P; Gray, C; Jones, S J
1994-01-01
Chick and rat bone-derived cells were mounted in sealed coverslip-covered chambers; individual osteoclasts (but also osteoblasts) were selected and studied at 37 degrees C using three different types of high-speed scanning confocal microscopes: (1) A Noran Tandem Scanning Microscope (TSM) was used with a low light level, cooled CCD camera for image transfer to a Noran TN8502 frame store-based image analysing computer to make time lapse movie sequences using 0.1 s exposure periods, thus losing some of the advantage of the high frame rate of the TSM. Rapid focus adjustment using computer controlled piezo drivers permitted two or more focus planes to be imaged sequentially: thus (with additional light-source shuttering) the reflection confocal image could be alternated with the phase contrast image at a different focus. Individual cells were followed for up to 5 days, suggesting no significant irradiation problem. (2) Exceptional temporal and spatial resolution is available in video rate laser confocal scanning microscopes (VRCSLMs). We used the Noran Odyssey unitary beam VRCSLM with an argon ion laser at 488 nm and acousto-optic deflection (AOD) on the line axis: this instrument is truly and adjustably confocal in the reflection mode. (3) We also used the Lasertec 1LM11 line scan instrument, with an He-Ne laser at 633 nm, and AOD for the frame scan. We discuss the technical problems and merits of the different approaches. The VRCSLMs documented rapid, real-time oscillatory motion: all the methods used show rapid net movement of organelles within bone cells. The interference reflection mode gives particularly strong contrasts in confocal instruments. Phase contrast and other interference methods used in the microscopy of living cells can be used simultaneously in the TSM.
Biphoton Generation Driven by Spatial Light Modulation: Parallel-to-Series Conversion
NASA Astrophysics Data System (ADS)
Zhao, Luwei; Guo, Xianxin; Sun, Yuan; Su, Yumian; Loy, M. M. T.; Du, Shengwang
2016-05-01
We demonstrate the generation of narrowband biphotons with controllable temporal waveform by spontaneous four-wave mixing in cold atoms. In the group-delay regime, we study the dependence of the biphoton temporal waveform on the spatial profile of the pump laser beam. By using a spatial light modulator, we manipulate the spatial profile of the pump laser and map it onto the two-photon entangled temporal wave function. This parallel-to-series conversion (or spatial-to-temporal mapping) enables coding the parallel classical information of the pump spatial profile to the sequential temporal waveform of the biphoton quantum state. The work was supported by the Hong Kong RGC (Project No. 601113).
Excimer Pumped Pulsed Tunable Dye Laser
NASA Astrophysics Data System (ADS)
Littman, Michael G.
1988-06-01
It has been recently shown and reported for the first time at this meeting, that Excimer pumping of a single-mode, short-cavity, grazing-incidence, longitudinally-pumped pulsed dye laser is feasible. In this paper the key concepts upon which this latest development is based are presented and are in a somewhat unusual form. This manuscript describes five specific dye laser examples. The five examples represent a progression from the simplest type of dye laser to the single-mode version mentioned above. The examples thus serve as a tutorial introduction to potential users of dye lasers. The article is organized into five sections or STEPS, each of which describes a different pulsed dye laser. Since the subtle points about dye lasers are best appreciated only after one actually attempts to build a working model, a PROCEDURES category is included in which details about the construction of the particular form of laser are given. As one reads through this category, think of it as looking over the shoulder of the laser builder. The NOTES category which follows is a brief but essential discussion explaining why various components and procedures are used, as well as how laser performance specifications are obtained. This subsection can he viewed as a discussion with the laser builder concerning the reasons for specific actions and choices made in the assembly of the example laser. The last category contains COMMENTS which provide additional related information pertaining to the example laser that goes beyond the earlier annotated discussion. If you like, these are the narrator's comments. At the end of the article, after the five sequential forms of the laser have been presented, there is a brief summation.
2015-03-26
INVESTIGATION OF THE HIGH -CYCLE FATIGUE LIFE OF SELECTIVE LASER MELTED AND HOT ISOSTATICALLY PRESSED TI-6AL-4V THESIS Kevin D. Rekedal...ENY-MS-15-M-212 INVESTIGATION OF THE HIGH -CYCLE FATIGUE LIFE OF SELECTIVE LASER MELTED AND HOT ISOSTATICALLY PRESSED TI-6AL-4V THESIS...AFIT-ENY-MS-15-M-212 INVESTIGATION OF THE HIGH -CYCLE FATIGUE LIFE OF SELECTIVE LASER MELTED AND HOT ISOSTATICALLY PRESSED TI-6AL-4V
Chang, Shih-Sheng; Shih, Che-Hao; Lai, Kwun-Cheng; Mong, Kwok-Kong Tony
2010-05-03
The beta-selectivity of mannosylation has been found to be dependent on the addition rate of the mannosyl trichloroacetimidate donor in an inverse-addition (I-A) procedure. This rate dependent I-A procedure can improve the selectivity of direct beta-mannosylation and is applicable to orthogonal glycosylations of thioglycoside acceptors. Further elaboration of this novel procedure enables the development of the contiguous sequential glycosylation strategy, which streamlines the preparation of oligosaccharides invoking beta-mannosidic bond formation. The synthetic utility of the contiguous glycosylation strategy was demonstrated by the preparation of the trisaccharide core of human N-linked glycoproteins and the trisaccharide repeating unit of the O-specific polysaccharide found in the cellular capsule of Salmonelle bacteria.
Beam shaping in high-power broad-area quantum cascade lasers using optical feedback
Ferré, Simon; Jumpertz, Louise; Carras, Mathieu; Ferreira, Robson; Grillot, Frédéric
2017-01-01
Broad-area quantum cascade lasers with high output powers are highly desirable sources for various applications including infrared countermeasures. However, such structures suffer from strongly deteriorated beam quality due to multimode behavior, diffraction of light and self-focusing. Quantum cascade lasers presenting high performances in terms of power and heat-load dissipation are reported and their response to a nonlinear control based on optical feedback is studied. Applying optical feedback enables to efficiently tailor its near-field beam profile. The different cavity modes are sequentially excited by shifting the feedback mirror angle. Further control of the near-field profile is demonstrated using spatial filtering. The impact of an inhomogeneous gain as well as the influence of the cavity width are investigated. Compared to existing technologies, that are complex and costly, beam shaping with optical feedback is a more flexible solution to obtain high-quality mid-infrared sources. PMID:28287175
Dynamic imaging with electron microscopy
Campbell, Geoffrey; McKeown, Joe; Santala, Melissa
2018-02-13
Livermore researchers have perfected an electron microscope to study fast-evolving material processes and chemical reactions. By applying engineering, microscopy, and laser expertise to the decades-old technology of electron microscopy, the dynamic transmission electron microscope (DTEM) team has developed a technique that can capture images of phenomena that are both very small and very fast. DTEM uses a precisely timed laser pulse to achieve a short but intense electron beam for imaging. When synchronized with a dynamic event in the microscope's field of view, DTEM allows scientists to record and measure material changes in action. A new movie-mode capability, which earned a 2013 R&D 100 Award from R&D Magazine, uses up to nine laser pulses to sequentially capture fast, irreversible, even one-of-a-kind material changes at the nanometer scale. DTEM projects are advancing basic and applied materials research, including such areas as nanostructure growth, phase transformations, and chemical reactions.
Sub-diffraction limit laser ablation via multiple exposures using a digital micromirror device.
Heath, Daniel J; Grant-Jacob, James A; Feinaeugle, Matthias; Mills, Ben; Eason, Robert W
2017-08-01
We present the use of digital micromirror devices as variable illumination masks for pitch-splitting multiple exposures to laser machine the surfaces of materials. Ultrafast laser pulses of length 150 fs and 800 nm central wavelength were used for the sequential machining of contiguous patterns on the surface of samples in order to build up complex structures with sub-diffraction limit features. Machined patterns of tens to hundreds of micrometers in lateral dimensions with feature separations as low as 270 nm were produced in electroless nickel on an optical setup diffraction limited to 727 nm, showing a reduction factor below the Abbe diffraction limit of ∼2.7×. This was compared to similar patterns in a photoresist optimized for two-photon absorption, which showed a reduction factor of only 2×, demonstrating that multiple exposures via ablation can produce a greater resolution enhancement than via two-photon polymerization.
Beam shaping in high-power broad-area quantum cascade lasers using optical feedback.
Ferré, Simon; Jumpertz, Louise; Carras, Mathieu; Ferreira, Robson; Grillot, Frédéric
2017-03-13
Broad-area quantum cascade lasers with high output powers are highly desirable sources for various applications including infrared countermeasures. However, such structures suffer from strongly deteriorated beam quality due to multimode behavior, diffraction of light and self-focusing. Quantum cascade lasers presenting high performances in terms of power and heat-load dissipation are reported and their response to a nonlinear control based on optical feedback is studied. Applying optical feedback enables to efficiently tailor its near-field beam profile. The different cavity modes are sequentially excited by shifting the feedback mirror angle. Further control of the near-field profile is demonstrated using spatial filtering. The impact of an inhomogeneous gain as well as the influence of the cavity width are investigated. Compared to existing technologies, that are complex and costly, beam shaping with optical feedback is a more flexible solution to obtain high-quality mid-infrared sources.
In situ analysis of DNA damage response and repair using laser microirradiation.
Kim, Jong-Soo; Heale, Jason T; Zeng, Weihua; Kong, Xiangduo; Krasieva, Tatiana B; Ball, Alexander R; Yokomori, Kyoko
2007-01-01
A proper response to DNA damage is critical for the maintenance of genome integrity. However, it is difficult to study the in vivo kinetics and factor requirements of the damage recognition process in mammalian cells. In order to address how the cell reacts to DNA damage, we utilized a second harmonic (532 nm) pulsed Nd:YAG laser to induce highly concentrated damage in a small area in interphase cell nuclei and cytologically analyzed both protein recruitment and modification. Our results revealed for the first time the sequential recruitment of factors involved in two major DNA double-strand break (DSB) repair pathways, non-homologous end-joining (NHEJ) and homologous recombination (HR), and the cell cycle-specific recruitment of the sister chromatid cohesion complex cohesin to the damage site. In this chapter, the strategy developed to study the DNA damage response using the 532-nm Nd:YAG laser will be summarized.
NASA Astrophysics Data System (ADS)
Yuren, Wang; Fang, Shao; Weiping, Sun; Xioujuan, Li; Suning, Tian; Hongyan, Li
1989-06-01
When a heavy-calibre gun is fired and a projectite is flying near the gun muzzle, velocity of the projectile is very high and firing process is accompanying with strong muzzle flash. So taking the picture of the attitudes of flying projectile at the gun muzzle is very difficult. "YDS speed Photography System" developed by our group can take the framing pictures of the attitudes of the projectile and prevent them from flash confusing at the muzzle. Since framing depends on sequential pulse of the laser and the width of the putse is very narrow, therefore the exposure time is very short and photos of high-velocity flying body taken are very clear. This paper Introduces configuration and operation principle of "YDS laser High-speed Photography System" and the fuctions of the devices in this system In addition, some experimental results are briefly introduced.
Scanning laser ophthalmoscopy: optimized testing strategies for psychophysics
NASA Astrophysics Data System (ADS)
Van de Velde, Frans J.
1996-12-01
Retinal function can be evaluated with the scanning laser ophthalmoscope (SLO). the main advantage is a precise localization of the psychophysical stimulus on the retina. Four alternative forced choice (4AFC) and parameter estimation by sequential testing (PEST) are classic adaptive algorithms that have been optimized for use with the SLO, and combined with strategies to correct for small eye movements. Efficient calibration procedures are essential for quantitative microperimetry. These techniques measure precisely visual acuity and retinal sensitivity at distinct locations on the retina. A combined 632 nm and IR Maxwellian view illumination provides a maximal transmittance through the ocular media and has a animal interference with xanthophyll or hemoglobin. Future modifications of the instrument include the possibility of binocular evaluation, Maxwellian view control, fundus tracking using normalized gray-scale correlation, and microphotocoagulation. The techniques are useful in low vision rehabilitation and the application of laser to the retina.
NASA Astrophysics Data System (ADS)
Pushkareva, A. E.; Ponomarev, I. V.; Isaev, A. A.; Klyuchareva, S. V.
2018-02-01
A computer simulation technique was employed to study the selective heating of a tissue vessel using emission from a pulsed copper vapor laser and a pulsed dye laser. The depth and size of vessels that could be selectively and safely removed were determined for the lasers under examination.
Hoomans, Ties; Severens, Johan L; Evers, Silvia M A A; Ament, Andre J H A
2009-01-01
Decisions about clinical practice change, that is, which guidelines to adopt and how to implement them, can be made sequentially or simultaneously. Decision makers adopting a sequential approach first compare the costs and effects of alternative guidelines to select the best set of guideline recommendations for patient management and subsequently examine the implementation costs and effects to choose the best strategy to implement the selected guideline. In an integral approach, decision makers simultaneously decide about the guideline and the implementation strategy on the basis of the overall value for money in changing clinical practice. This article demonstrates that the decision to use a sequential v. an integral approach affects the need for detailed information and the complexity of the decision analytic process. More importantly, it may lead to different choices of guidelines and implementation strategies for clinical practice change. The differences in decision making and decision analysis between the alternative approaches are comprehensively illustrated using 2 hypothetical examples. We argue that, in most cases, an integral approach to deciding about change in clinical practice is preferred, as this provides more efficient use of scarce health-care resources.
Martin, J.C.; Buican, T.N.
1987-11-30
Method and apparatus are provided for sorting particles, such as biological particles. A first laser is used to define an optical path having an intensity gradient which is effective to propel the particles along the path but which is sufficiently weak that the particles are not trapped in an axial direction. A probe laser beam is provided for interrogating the particles to identify predetermined phenotypical characteristics of the particles. A second laser beam is provided to intersect the driving first laser beam, wherein the second laser beam is activated by an output signal indicative of a predetermined characteristic. The second laser beam is switchable between a first intensity and a second intensity, where the first intensity is effective to displace selected particles from the driving laser beam and the second intensity is effective to propel selected particles along the deflection laser beam. The selected particles may then be propelled by the deflection beam to a location effective for further analysis. 2 figs.
Martin, John C.; Buican, Tudor N.
1989-01-01
Method and apparatus for sorting particles, such as biological particles. A first laser defines an optical path having an intensity gradient which is effective to propel the particles along the path but which is sufficiently weak that the particles are not trapped in an axial direction. A probe laser beam interrogates the particles to identify predetermined phenotypical characteristics of the particles. A second laser beam intersects the driving first laser beam, wherein the second laser beam is activated by an output signal indicative of a predetermined characteristic. The second laser beam is switchable between a first intensity and a second intensity, where the first intensity is effective to displace selected particles from the driving laser beam and the second intensity is effective to propel selected particles along the deflection laser beam. The selected particles may then be propelled by the deflection beam to a location effective for further analysis.
Ghayab, Hadi Ratham Al; Li, Yan; Abdulla, Shahab; Diykh, Mohammed; Wan, Xiangkui
2016-06-01
Electroencephalogram (EEG) signals are used broadly in the medical fields. The main applications of EEG signals are the diagnosis and treatment of diseases such as epilepsy, Alzheimer, sleep problems and so on. This paper presents a new method which extracts and selects features from multi-channel EEG signals. This research focuses on three main points. Firstly, simple random sampling (SRS) technique is used to extract features from the time domain of EEG signals. Secondly, the sequential feature selection (SFS) algorithm is applied to select the key features and to reduce the dimensionality of the data. Finally, the selected features are forwarded to a least square support vector machine (LS_SVM) classifier to classify the EEG signals. The LS_SVM classifier classified the features which are extracted and selected from the SRS and the SFS. The experimental results show that the method achieves 99.90, 99.80 and 100 % for classification accuracy, sensitivity and specificity, respectively.
Sequential two-photon double ionization of noble gases by circularly polarized XUV radiation
NASA Astrophysics Data System (ADS)
Gryzlova, E. V.; Grum-Grzhimailo, A. N.; Kuzmina, E. I.; Strakhova, S. I.
2014-10-01
Photoelectron angular distributions (PADs) and angular correlations between two emitted electrons in sequential two-photon double ionization (2PDI) of atoms by circularly polarized radiation are studied theoretically. In particular, the sequential 2PDI of the valence n{{p}6} shell in noble gas atoms (neon, argon, krypton) is analyzed, accounting for the first-order corrections to the dipole approximation. Due to different selection rules in ionization transitions, the circular polarization of photons causes some new features of the cross sections, PADs and angular correlation functions in comparison with the case of linearly polarized photons.
NASA Astrophysics Data System (ADS)
Bobrovnikov, S. M.; Gorlov, E. V.; Zharkov, V. I.
2018-05-01
A technique for increasing the selectivity of the method of detecting high-energy materials (HEMs) based on laser fragmentation of HEM molecules with subsequent laser excitation of fluorescence of the characteristic NO fragments from the first vibrational level of the ground state is suggested.
Combining Raman and laser induced breakdown spectroscopy by double pulse lasing.
Lednev, Vasily N; Pershin, Sergey M; Sdvizhenskii, Pavel A; Grishin, Mikhail Ya; Fedorov, Alexander N; Bukin, Vladimir V; Oshurko, Vadim B; Shchegolikhin, Alexander N
2018-01-01
A new approach combining Raman spectrometry and laser induced breakdown spectrometry (LIBS) within a single laser event was suggested. A pulsed solid state Nd:YAG laser running in double pulse mode (two frequency-doubled sequential nanosecond laser pulses with dozens microseconds delay) was used to combine two spectrometry methods within a single instrument (Raman/LIBS spectrometer). First, a low-energy laser pulse (power density far below ablation threshold) was used for Raman measurements while a second powerful laser pulse created the plasma suitable for LIBS analysis. A short time delay between two successive pulses allows measuring LIBS and Raman spectra at different moments but within a single laser flash-lamp pumping. Principal advantages of the developed instrument include high quality Raman/LIBS spectra acquisition (due to optimal gating for Raman/LIBS independently) and absence of target thermal alteration during Raman measurements. A series of high quality Raman and LIBS spectra were acquired for inorganic salts (gypsum, anhydrite) as well as for pharmaceutical samples (acetylsalicylic acid). To the best of our knowledge, the quantitative analysis feasibility by combined Raman/LIBS instrument was demonstrated for the first time by calibration curves construction for acetylsalicylic acid (Raman) and copper (LIBS) in gypsum matrix. Combining ablation pulses and Raman measurements (LIBS/Raman measurements) within a single instrument makes it an efficient tool for identification of samples hidden by non-transparent covering or performing depth profiling analysis including remote sensing. Graphical abstract Combining Raman and laser induced breakdown spectroscopy by double pulse lasing.
Olivoto, T; Nardino, M; Carvalho, I R; Follmann, D N; Ferrari, M; Szareski, V J; de Pelegrin, A J; de Souza, V Q
2017-03-22
Methodologies using restricted maximum likelihood/best linear unbiased prediction (REML/BLUP) in combination with sequential path analysis in maize are still limited in the literature. Therefore, the aims of this study were: i) to use REML/BLUP-based procedures in order to estimate variance components, genetic parameters, and genotypic values of simple maize hybrids, and ii) to fit stepwise regressions considering genotypic values to form a path diagram with multi-order predictors and minimum multicollinearity that explains the relationships of cause and effect among grain yield-related traits. Fifteen commercial simple maize hybrids were evaluated in multi-environment trials in a randomized complete block design with four replications. The environmental variance (78.80%) and genotype-vs-environment variance (20.83%) accounted for more than 99% of the phenotypic variance of grain yield, which difficult the direct selection of breeders for this trait. The sequential path analysis model allowed the selection of traits with high explanatory power and minimum multicollinearity, resulting in models with elevated fit (R 2 > 0.9 and ε < 0.3). The number of kernels per ear (NKE) and thousand-kernel weight (TKW) are the traits with the largest direct effects on grain yield (r = 0.66 and 0.73, respectively). The high accuracy of selection (0.86 and 0.89) associated with the high heritability of the average (0.732 and 0.794) for NKE and TKW, respectively, indicated good reliability and prospects of success in the indirect selection of hybrids with high-yield potential through these traits. The negative direct effect of NKE on TKW (r = -0.856), however, must be considered. The joint use of mixed models and sequential path analysis is effective in the evaluation of maize-breeding trials.
Immediately sequential bilateral cataract surgery: advantages and disadvantages.
Singh, Ranjodh; Dohlman, Thomas H; Sun, Grace
2017-01-01
The number of cataract surgeries performed globally will continue to rise to meet the needs of an aging population. This increased demand will require healthcare systems and providers to find new surgical efficiencies while maintaining excellent surgical outcomes. Immediately sequential bilateral cataract surgery (ISBCS) has been proposed as a solution and is increasingly being performed worldwide. The purpose of this review is to discuss the advantages and disadvantages of ISBCS. When appropriate patient selection occurs and guidelines are followed, ISBCS is comparable with delayed sequential bilateral cataract surgery in long-term patient satisfaction, visual acuity and complication rates. In addition, the risk of bilateral postoperative endophthalmitis and concerns of poorer refractive outcomes have not been supported by the literature. ISBCS is cost-effective for the patient, healthcare payors and society, but current reimbursement models in many countries create significant financial barriers for facilities and surgeons. As demand for cataract surgery rises worldwide, ISBCS will become increasingly important as an alternative to delayed sequential bilateral cataract surgery. Advantages include potentially decreased wait times for surgery, patient convenience and cost savings for healthcare payors. Although they are comparable in visual acuity and complication rates, hurdles that prevent wide adoption include liability concerns as ISBCS is not an established standard of care, economic constraints for facilities and surgeons and inability to fine-tune intraocular lens selection in the second eye. Given these considerations, an open discussion regarding the advantages and disadvantages of ISBCS is important for appropriate patient selection.
Selective laser ablation of carious lesions using simultaneous scanned near-IR diode and CO2 lasers
NASA Astrophysics Data System (ADS)
Chan, Kenneth H.; Fried, Daniel
2017-02-01
Previous studies have established that carious lesions can be imaged with high contrast using near-IR wavelengths coincident with high water absorption, namely 1450-nm, without the interference of stains. It has been demonstrated that computer-controlled laser scanning systems utilizing IR lasers operating at high pulse repetition rates can be used for serial imaging and selective removal of caries lesions. In this study, a point-to-point scanning system was developed integrating a 1450-nm diode laser with the CO2 ablation laser. This approach is advantageous since it does not require an expensive near-IR camera. In this pilot study, we demonstrate the feasibility of a combined NIR and IR laser system for the selective removal of carious lesions.
Selective Laser Ablation of Carious Lesions using Simultaneous Scanned Near-IR Diode and CO2 Lasers.
Chan, Kenneth H; Fried, Daniel
2017-01-28
Previous studies have established that carious lesions can be imaged with high contrast using near-IR wavelengths coincident with high water absorption, namely 1450-nm, without the interference of stains. It has been demonstrated that computer-controlled laser scanning systems utilizing IR lasers operating at high pulse repetition rates can be used for serial imaging and selective removal of caries lesions. In this study, a point-to-point scanning system was developed integrating a 1450-nm diode laser with the CO 2 ablation laser. This approach is advantageous since it does not require an expensive near-IR camera. In this pilot study, we demonstrate the feasibility of a combined NIR and IR laser system for the selective removal of carious lesions.
Assessing laser-tissue damage with bioluminescent imaging
NASA Astrophysics Data System (ADS)
Wilmink, Gerald J.; Opalenik, Susan R.; Beckham, Josh T.; Davidson, Jeffrey M.; Jansen, Eric D.
2006-07-01
Effective medical laser procedures are achieved by selecting laser parameters that minimize undesirable tissue damage. Traditionally, human subjects, animal models, and monolayer cell cultures have been used to study wound healing, tissue damage, and cellular effects of laser radiation. Each of these models has significant limitations, and consequently, a novel skin model is needed. To this end, a highly reproducible human skin model that enables noninvasive and longitudinal studies of gene expression was sought. In this study, we present an organotypic raft model (engineered skin) used in combination with bioluminescent imaging (BLI) techniques. The efficacy of the raft model was validated and characterized by investigating the role of heat shock protein 70 (hsp70) as a sensitive marker of thermal damage. The raft model consists of human cells incorporated into an extracellular matrix. The raft cultures were transfected with an adenovirus containing a murine hsp70 promoter driving transcription of luciferase. The model enables quantitative analysis of spatiotemporal expression of proteins using BLI. Thermal stress was induced on the raft cultures by means of a constant temperature water bath or with a carbon dioxide (CO2) laser (λ=10.6 µm, 0.679 to 2.262 W/cm2, cw, unfocused Gaussian beam, ωL=4.5 mm, 1 min exposure). The bioluminescence was monitored noninvasively with an IVIS 100 Bioluminescent Imaging System. BLI indicated that peak hsp70 expression occurs 4 to 12 h after exposure to thermal stress. A minimum irradiance of 0.679 W/cm2 activated the hsp70 response, and a higher irradiance of 2.262 W/cm2 was associated with a severe reduction in hsp70 response due to tissue ablation. Reverse transcription polymerase chain reaction demonstrated that hsp70 mRNA levels increased with prolonged heating exposures. Enzyme-linked immunosorbent protein assays confirmed that luciferase was an accurate surrogate for hsp70 intracellular protein levels. Hematoxylin and eosin stains verified the presence of the thermally denatured tissue regions. Immunohistochemical analyses confirmed that maximal hsp70 expression occurred at a depth of 150 µm. Bioluminescent microscopy was employed to corroborate these findings. These results indicate that quantitative BLI in engineered tissue equivalents provides a powerful model that enables sequential gene expression studies. Such a model can be used as a high throughput screening platform for laser-tissue interaction studies.
Laser engines operating by resonance absorption. [thermodynamic feasibility study
NASA Technical Reports Server (NTRS)
Garbuny, M.; Pechersky, M. J.
1976-01-01
Basic tutorial article on the thermodynamic feasibility of laser engines at the present state of the art. Three main options are considered: (1) laser power applied externally to a heat reservoir (boiler approach); (2) internal heating of working fluid by resonance absorption; and (3) direct conversion of selective excitation into work. Only (2) is considered practically feasible at present. Basic concepts and variants, efficiency relations, upper temperature limits of laser engines, selection of absorbing gases, engine walls, bleaching, thermodynamic cycles of optimized laser engines, laser-powered turbines, laser heat pumps are discussed. Photon engines and laser dissociation engines are also considered.
Multiple-Diode-Laser Gas-Detection Spectrometer
NASA Technical Reports Server (NTRS)
Webster, Christopher R.; Beer, Reinhard; Sander, Stanley P.
1988-01-01
Small concentrations of selected gases measured automatically. Proposed multiple-laser-diode spectrometer part of system for measuring automatically concentrations of selected gases at part-per-billion level. Array of laser/photodetector pairs measure infrared absorption spectrum of atmosphere along probing laser beams. Adaptable to terrestrial uses as monitoring pollution or control of industrial processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nong, Hanond, E-mail: Nong.Hanond@rub.de; Markmann, Sergej; Hekmat, Negar
2014-09-15
A periodically poled lithium niobate (PPLN) crystal with multiple poling periods is used to generate tunable narrow-bandwidth THz pulses for injection seeding a quantum cascade laser (QCL). We demonstrate that longitudinal modes of the quantum cascade laser close to the gain maximum can be selected or suppressed according to the seed spectrum. The QCL emission spectra obtained by electro-optic sampling from the quantum cascade laser, in the most favorable case, shows high selectivity and amplification of the longitudinal modes that overlap the frequency of the narrow-band seed. Proper selection of the narrow-band THz seed from the PPLN crystal discretely tunesmore » the longitudinal mode emission of the quantum cascade laser. Moreover, the THz wave build-up within the laser cavity is studied as a function of the round-trip time. When the seed frequency is outside the maximum of the gain spectrum the laser emission shifts to the preferential longitudinal mode.« less
ERIC Educational Resources Information Center
Seiverling, Laura; Harclerode, Whitney; Williams, Keith
2014-01-01
The purpose of this study was to examine if sequential presentation with feeder modeling would lead to an increase in bites accepted of new foods compared to sequential presentation without feeder modeling in a typically developing 4-year-old boy with food selectivity. The participant's acceptance of novel foods increased both in the modeling and…
Additive Manufacturing of Al-12Si Alloy Via Pulsed Selective Laser Melting
NASA Astrophysics Data System (ADS)
Chou, R.; Milligan, J.; Paliwal, M.; Brochu, M.
2015-03-01
Additive manufacturing (AM) of metallic materials is experiencing a research and commercialization craze in almost all industrial sectors. However, to date, AM has been limited to a small numbers of alloys. With respect to aluminum, two alloys received some attention: Al-12Si and Al-10Si-1Mg. In both cases, fully dense components have been achieved using a continuous-wave selective laser melting system. In this article, a new approach of selective laser melting using a pulsed-laser source as opposed to a continuous-wave laser is proposed. Pulse selective laser melting (P-SLM) would allow for greater control over the heat input and thus further optimization possibilities of the microstructure. P-SLM was demonstrated using the Al-12Si system. Si refinement below 200 nm was achieved throughout the component. Density up to 95% and high hardness of above 135 HV were obtained. The solidification mechanism is also explained.
Kwon, Jinhyeong; Cho, Hyunmin; Eom, Hyeonjin; Lee, Habeom; Suh, Young Duk; Moon, Hyunjin; Shin, Jaeho; Hong, Sukjoon; Ko, Seung Hwan
2016-05-11
Copper nanomaterials suffer from severe oxidation problem despite the huge cost effectiveness. The effect of two different processes for conventional tube furnace heating and selective laser sintering on copper nanoparticle paste is compared in the aspects of chemical, electrical and surface morphology. The thermal behavior of the copper thin films by furnace and laser is compared by SEM, XRD, FT-IR, and XPS analysis. The selective laser sintering process ensures low annealing temperature, fast processing speed with remarkable oxidation suppression even in air environment while conventional tube furnace heating experiences moderate oxidation even in Ar environment. Moreover, the laser-sintered copper nanoparticle thin film shows good electrical property and reduced oxidation than conventional thermal heating process. Consequently, the proposed selective laser sintering process can be compatible with plastic substrate for copper based flexible electronics applications.
Distribution and avoidance of debris on epoxy resin during UV ns-laser scanning processes
NASA Astrophysics Data System (ADS)
Veltrup, Markus; Lukasczyk, Thomas; Ihde, Jörg; Mayer, Bernd
2018-05-01
In this paper the distribution of debris generated by a nanosecond UV laser (248 nm) on epoxy resin and the prevention of the corresponding re-deposition effects by parameter selection for a ns-laser scanning process were investigated. In order to understand the mechanisms behind the debris generation, in-situ particle measurements were performed during laser treatment. These measurements enabled the determination of the ablation threshold of the epoxy resin as well as the particle density and size distribution in relation to the applied laser parameters. The experiments showed that it is possible to reduce debris on the surface with an adapted selection of pulse overlap with respect to laser fluence. A theoretical model for the parameter selection was developed and tested. Based on this model, the correct choice of laser parameters with reduced laser fluence resulted in a surface without any re-deposited micro-particles.
Rapid Prototyping: State of the Art
2003-10-23
Rapid Prototyping SCS Solid Creation System SLM Selective Laser Melting SLP Solid Laser diode Plotter SLS Selective Laser Sintering SOAR State of the...121,000, respectively. SLP stands for Sold Laser Diode Plotter. The machines are relatively slow and parts are small, so, to date, the products have been...Gigerenzer, H., “Directed Laser Welding of Metal Matrix Composite Structures for Space Based Applications,“ Triton Systems Inc., Chelmsford, MA., 1
Lade, Harshad; Kadam, Avinash; Paul, Diby; Govindwar, Sanjay
2015-01-01
Release of textile azo dyes to the environment is an issue of health concern while the use of microorganisms has proved to be the best option for remediation. Thus, in the present study, a bacterial consortium consisting of Providencia rettgeri strain HSL1 and Pseudomonas sp. SUK1 has been investigated for degradation and detoxification of structurally different azo dyes. The consortium showed 98-99 % decolorization of all the selected azo dyes viz. Reactive Black 5 (RB 5), Reactive Orange 16 (RO 16), Disperse Red 78 (DR 78) and Direct Red 81 (DR 81) within 12 to 30 h at 100 mg L-1 concentration at 30 ± 0.2 °C under microaerophilic, sequential aerobic/microaerophilic and microaerophilic/aerobic processes. However, decolorization under microaerophilic conditions viz. RB 5 (0.26 mM), RO 16 (0.18 mM), DR 78 (0.20 mM) and DR 81 (0.23 mM) and sequential aerobic/microaerophilic processes viz. RB 5 (0.08 mM), RO 16 (0.06 mM), DR 78 (0.07 mM) and DR 81 (0.09 mM) resulted into the formation of aromatic amines. In distinction, sequential microaerophilic/ aerobic process doesn’t show the formation of amines. Additionally, 62-72 % reduction in total organic carbon content was observed in all the dyes decolorized broths under sequential microaerophilic/aerobic processes suggesting the efficacy of method in mineralization of dyes. Notable induction within the levels of azoreductase and NADH-DCIP reductase (97 and 229 % for RB 5, 55 and 160 % for RO 16, 63 and 196 % for DR 78, 108 and 258 % for DR 81) observed under sequential microaerophilic/aerobic processes suggested their critical involvements in the initial breakdown of azo bonds, whereas, a slight increase in the levels of laccase and veratryl alcohol oxidase confirmed subsequent oxidation of formed amines. Also, the acute toxicity assay with Daphnia magna revealed the nontoxic nature of the dye-degraded metabolites under sequential microaerophilic/aerobic processes. As biodegradation under sequential microaerophilic/aerobic process completely detoxified all the selected textile azo dyes, further efforts should be made to implement such methods for large scale dye wastewater treatment technologies. PMID:26417357
Feature Selection based on Machine Learning in MRIs for Hippocampal Segmentation
NASA Astrophysics Data System (ADS)
Tangaro, Sabina; Amoroso, Nicola; Brescia, Massimo; Cavuoti, Stefano; Chincarini, Andrea; Errico, Rosangela; Paolo, Inglese; Longo, Giuseppe; Maglietta, Rosalia; Tateo, Andrea; Riccio, Giuseppe; Bellotti, Roberto
2015-01-01
Neurodegenerative diseases are frequently associated with structural changes in the brain. Magnetic resonance imaging (MRI) scans can show these variations and therefore can be used as a supportive feature for a number of neurodegenerative diseases. The hippocampus has been known to be a biomarker for Alzheimer disease and other neurological and psychiatric diseases. However, it requires accurate, robust, and reproducible delineation of hippocampal structures. Fully automatic methods are usually the voxel based approach; for each voxel a number of local features were calculated. In this paper, we compared four different techniques for feature selection from a set of 315 features extracted for each voxel: (i) filter method based on the Kolmogorov-Smirnov test; two wrapper methods, respectively, (ii) sequential forward selection and (iii) sequential backward elimination; and (iv) embedded method based on the Random Forest Classifier on a set of 10 T1-weighted brain MRIs and tested on an independent set of 25 subjects. The resulting segmentations were compared with manual reference labelling. By using only 23 feature for each voxel (sequential backward elimination) we obtained comparable state-of-the-art performances with respect to the standard tool FreeSurfer.
Synthesis of the PPARbeta/delta-selective agonist GW501516 and C4-thiazole-substituted analogs.
Pereira, Raquel; Gaudon, Claudine; Iglesias, Beatriz; Germain, Pierre; Gronemeyer, Hinrich; de Lera, Angel R
2006-01-01
Sequential, position-selective, Pd-catalyzed cross-coupling reactions of 2,4-dibromo-5-hydroxymethylthiazole provided the scaffold for the synthesis of GW501516, the most potent PPARbeta/delta agonist yet described, and equally selective analogs at the thiazole-C4 position.
Thermophysics Characterization of Multiply Ionized Air Plasma Absorption of Laser Radiation
NASA Technical Reports Server (NTRS)
Wang, Ten-See; Rhodes, Robert; Turner, Jim (Technical Monitor)
2002-01-01
The impact of multiple ionization of air plasma on the inverse Bremsstrahlung absorption of laser radiation is investigated for air breathing laser propulsion. Thermochemical properties of multiply ionized air plasma species are computed for temperatures up to 200,000 deg K, using hydrogenic approximation of the electronic partition function; And those for neutral air molecules are also updated for temperatures up to 50,000 deg K, using available literature data. Three formulas for absorption are calculated and a general formula is recommended for multiple ionization absorption calculation. The plasma composition required for absorption calculation is obtained by increasing the degree of ionization sequentially, up to quadruple ionization, with a series of thermal equilibrium computations. The calculated second ionization absorption coefficient agrees reasonably well with that of available data. The importance of multiple ionization modeling is demonstrated with the finding that area under the quadruple ionization curve of absorption is found to be twice that of single ionization. The effort of this work is beneficial to the computational plasma aerodynamics modeling of laser lightcraft performance.
NASA Astrophysics Data System (ADS)
Takeuchi, Eric B.; Flint, Graham W.; Bergstedt, Robert; Solone, Paul J.; Lee, Dicky; Moulton, Peter F.
2001-03-01
Electronic cinema projectors are being developed that use a digital micromirror device (DMDTM) to produce the image. Photera Technologies has developed a new architecture that produces truly digital imagery using discrete pulse trains of red, green, and blue light in combination with a DMDTM where in the number of pulses that are delivered to the screen during a given frame can be defined in a purely digital fashion. To achieve this, a pulsed RGB laser technology pioneered by Q-Peak is combined with a novel projection architecture that we refer to as Laser Digital CameraTM. This architecture provides imagery wherein, during the time interval of each frame, individual pixels on the screen receive between zero and 255 discrete pulses of each color; a circumstance which yields 24-bit color. Greater color depth, or increased frame rate is achievable by increasing the pulse rate of the laser. Additionally, in the context of multi-screen theaters, a similar architecture permits our synchronously pulsed RGB source to simultaneously power three screens in a color sequential manner; thereby providing an efficient use of photons, together with the simplifications which derive from using a single DMDTM chip in each projector.
Methods for Selecting Phage Display Antibody Libraries.
Jara-Acevedo, Ricardo; Diez, Paula; Gonzalez-Gonzalez, Maria; Degano, Rosa Maria; Ibarrola, Nieves; Gongora, Rafael; Orfao, Alberto; Fuentes, Manuel
2016-01-01
The selection process aims sequential enrichment of phage antibody display library in clones that recognize the target of interest or antigen as the library undergoes successive rounds of selection. In this review, selection methods most commonly used for phage display antibody libraries have been comprehensively described. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
NASA Astrophysics Data System (ADS)
Jew, Jamison; Chan, Kenneth H.; Darling, Cynthia L.; Fried, Daniel
2017-02-01
Selective removal of caries lesions with high precision is best accomplished using lasers operating at high pulse repetition rates utilizing small spot sizes. Conventional flash-lamp pumped Er:YAG lasers are poorly suited for this purpose, but new diode-pumped solid-state (DPSS) Er:YAG lasers have become available operating at high pulse repetition rates. Microradiography was used to determine the mineral content of the demineralized dentin of 200-μm thick sections with natural caries lesions prior to laser ablation. The purpose of this study was to explore the use of a DPSS Er:YAG laser for the selective removal of demineralized dentin and natural occlusal lesions on extracted teeth.
Stress assisted selective ablation of ITO thin film by picosecond laser
NASA Astrophysics Data System (ADS)
Farid, Nazar; Chan, Helios; Milne, David; Brunton, Adam; M. O'Connor, Gerard
2018-01-01
Fast selective pattering with high precession on 175 nm ITO thin film with IR ps lasers is investigated. Ablation parameters are optimized with detailed studies on the scribed depth, topography, and particle generation using AFM and SEM. A comparison of 10 and 150 ps laser revealed that the shorter pulse (10 ps) laser is more appropriate in selective and partial ablation; up to 20 nm resolution for controlled depth with multipulses having energy below the damage threshold is demonstrated. The experimental results are interpreted to involve stress assisted ablation mechanism for the 10 ps laser while thermal ablation along with intense melting occurs for 150 ps laser. The transition between these regimes is estimated to occur at approximately 30 ps.
Application of a multi-beam vibrometer on industrial components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bendel, Karl
2014-05-27
Laser Doppler vibrometry is a well proven tool for the non-contact measurement of vibration. The scanning of several measurement points allows to visualize the deflection shape of the component, ideally a 3D-operating deflection shape, if a 3-D scanner is applied. Measuring the points sequentially, however, requires stationary behavior during the measurement time. This cannot be guaranteed for many real objects. Therefore, a multipoint laser Doppler vibrometer has been developed by Polytec and the University of Stuttgart with Bosch as industrial partner. A short description of the measurement system is given. Applications for the parallel measurement of the vibration of severalmore » points are shown for non-stationary vibrating Bosch components such as power-tools or valves.« less
Structural drift: the population dynamics of sequential learning.
Crutchfield, James P; Whalen, Sean
2012-01-01
We introduce a theory of sequential causal inference in which learners in a chain estimate a structural model from their upstream "teacher" and then pass samples from the model to their downstream "student". It extends the population dynamics of genetic drift, recasting Kimura's selectively neutral theory as a special case of a generalized drift process using structured populations with memory. We examine the diffusion and fixation properties of several drift processes and propose applications to learning, inference, and evolution. We also demonstrate how the organization of drift process space controls fidelity, facilitates innovations, and leads to information loss in sequential learning with and without memory.
Up-conversion in rare-earth doped micro-particles applied to new emissive two-dimensional displays
NASA Astrophysics Data System (ADS)
Milliez, Anne Janet
Up-conversion (UC) in rare-earth co-doped fluorides to convert diode laser light in the near infrared to red, green and blue visible light is applied to make possible high performance emissive displays. The infrared-to-visible UC in the materials we study is a sequential form of non-linear two photon absorption in which a strong absorbing constituent absorbs two low energy photons and transfers this energy to another constituent which emits visible light. Some of the UC emitters' most appealing characteristics for displays are: a wide color gamut with very saturated colors, very high brightness operation without damage to the emitters, long lifetimes and efficiencies comparable to those of existing technologies. Other advantages include simplicity of fabrication, versatility of operating modes, and the potential for greatly reduced display weight and depth. Thanks to recent advances in material science and diode laser technology at the excitation wavelength, UC selected materials can be very efficient visible emitters. However, optimal UC efficiencies strongly depend on chosing proper operating conditions. In this thesis, we studied the conditions required for optimization. We demonstrated that high efficiency UC depends on high pump irradiance, low temperature and low scattering. With this understanding we can predict how to optimally use UC emitters in a wide range of applications. In particular, we showed how our very efficient UC emitters can be applied to make full color displays and very efficient white light sources.
Forced guidance and distribution of practice in sequential information processing.
NASA Technical Reports Server (NTRS)
Decker, L. R.; Rogers, C. A., Jr.
1973-01-01
Distribution of practice and forced guidance were used in a sequential information-processing task in an attempt to increase the capacity of human information-processing mechanisms. A reaction time index of the psychological refractory period was used as the response measure. Massing of practice lengthened response times while forced guidance shortened them. Interpretation was in terms of load reduction upon the response-selection stage of the information-processing system.-
Ishida, Naoki; Nečas, David; Masuda, Yusuke; Murakami, Masahiro
2015-06-15
3-Hydroxypiperidine scaffolds were enantioselectively constructed in an atom-economical way by sequential action of light and rhodium upon N-allylglyoxylamides. In a formal sense, the allylic C-H bond was selectively cleaved and enantioselectively added across the ketonic carbonyl group with migration of the double bond (carbonyl-ene-type reaction). © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Selective ablation of dental calculus with a frequency-doubled Alexandrite laser
NASA Astrophysics Data System (ADS)
Rechmann, Peter; Hennig, Thomas
1996-01-01
The aim of the study was the selective removal of dental calculus by means of pulsed lasers. In a first approach the optical characteristics of subgingival calculus were calculated using fluorescence emission spectroscopy (excitation laser: N2-laser, wavelength 337 nm, pulse duration 4 ns). Subgingival calculus seems to absorb highly in the ultraviolet spectral region up to 420 nm. According to these measurements a frequency doubled Alexandrite-laser (wavelength 377 nm, pulse duration 100 ns, repetition rate 110 Hz) was used to irradiate calculus located on enamel, at the cementum enamel junction and on the root surface (located on dentin or on cementum). Irradiation was performed perpendicular to the root surface with a laser fluence of 1 Jcm-2. During the irradiation procedure an effective water cooling-system was engaged. Histological investigations were done on undecalcified sections. As a result, engaging low fluences allows a fast and strictly selective removal of subgingival calculus. Even more the investigations revealed that supragingival calculus can be removed in a strictly selective manner engaging a frequency doubled Alexandrite-laser. No adverse side effects to the surrounding tissues could be found.
Selective removal of dental composite using a rapidly scanned carbon dioxide laser
NASA Astrophysics Data System (ADS)
Chan, Kenneth H.; Fried, Daniel
2011-03-01
Dental restorative materials are color matched to the tooth and are difficult to remove by mechanical means without excessive removal or damage to peripheral enamel and dentin. Lasers are ideally suited for selective ablation to minimize healthy tissue loss when replacing existing restorations, sealants or removing composite adhesives such as residual composite left after debonding orthodontic brackets. In this study a carbon dioxide laser operating at high laser pulse repetition rates integrated with a galvanometer based scanner was used to selectively remove composite from tooth surfaces. A diode array spectrometer was used to measure the plume emission after each laser pulse and determine if the ablated material was tooth mineral or composite. The composite was placed on tooth buccal and occlusal surfaces and the carbon dioxide laser was scanned across the surface to selectively remove the composite without excessive damage to the underlying sound enamel. The residual composite and the damage to the underlying enamel was evaluated using optical microscopy. The laser was able to rapidly remove the composites rapidly from both surfaces with minimal damage to the underlying sound enamel.
Masaki, Noritaka; Okazaki, Shigetoshi
2018-01-01
The recent development of quantum cascade lasers (QCLs) has facilitated the irradiation of a mid-infrared laser beam that is specifically absorbed by a target molecular bond. Aiming for a selective delivery of laser energy to a specific absorption at 1,738 cm−1 by the ester bonds of triacylglycerol (TAG), a QCL beam with a wavenumber of 1,710 cm−1 was irradiated to 3T3–L1 adipocytes and preadipocytes. Neutral red staining, and FITC-labeled annexin V and ethidium homodimer-III assays revealed the occurrence of adipocyte-specific cell death 24 h after QCL irradiation. The selective delivery of laser energy to endogenous molecules can affect biological processes in a living organism. PMID:29760972
Masaki, Noritaka; Okazaki, Shigetoshi
2018-05-01
The recent development of quantum cascade lasers (QCLs) has facilitated the irradiation of a mid-infrared laser beam that is specifically absorbed by a target molecular bond. Aiming for a selective delivery of laser energy to a specific absorption at 1,738 cm -1 by the ester bonds of triacylglycerol (TAG), a QCL beam with a wavenumber of 1,710 cm -1 was irradiated to 3T3-L1 adipocytes and preadipocytes. Neutral red staining, and FITC-labeled annexin V and ethidium homodimer-III assays revealed the occurrence of adipocyte-specific cell death 24 h after QCL irradiation. The selective delivery of laser energy to endogenous molecules can affect biological processes in a living organism.
The choice: Welding with CO2 or Nd:YAG lasers
NASA Astrophysics Data System (ADS)
Leong, Keng H.
The recent commercial availability of multi-kilowatt Nd:YAG lasers has opened new avenues for rapid laser processing as well as intensified the competition (cost effectiveness) between CO2 and Nd:YAG laser systems. Vendors offering Nd:YAG laser systems may claim lower operating costs (than CO2) and fiberoptic beam delivery flexibility while CO2 systems vendors may emphasize lower capital cost and well established processing requirements and experience. The capital and operating costs of a laser system are impacted by demand and supply economics and technological advances. Frequently the total cost of a workcell using a laser for processing has to be considered rather than the laser system alone. Consequently it is not very practical to approach the selection of a laser system based on its capital cost and estimated operating cost only. This presentation describes a more pragmatic approach to aid the user in the selection of the optimal multi-kilowatt laser system for a particular processing requirement with emphasis on welding. CO2 laser systems are well established on the factory floor. Consequently, emphasis is given to the comparative application of Nd:YAG lasers, process requirements and performance. Requirements for the laser welding of different metals are examined in the context of hardware (laser system and beam delivery) selection and examples of welding speeds that can be achieved using CO2 and Nd:YAG lasers are examined.
Optical design of f-theta lens for dual wavelength selective laser melting
NASA Astrophysics Data System (ADS)
Feng, Lianhua; Cao, Hongzhong; Zhang, Ning; Xu, Xiping; Duan, Xuanming
2016-10-01
F-theta lens is an important unit for selective laser melting (SLM) manufacture. The dual wavelength f-theta lens has not been used in SLM manufacture. Here, we present the design of the f-theta lens which satisfies SLM manufacture with coaxial 532 nm and 1030 nm 1080 nm laser beams. It is composed of three pieces of spherical lenses. The focal spots for 532 nm laser and 1030 nm 1080 nm laser are smaller than 35 μm and 70 μm, respectively. The results meet the demands of high precision SLM. The chromatic aberration could cause separation between two laser focal spots in the scanning plane, so chromatic aberration correction is very important to our design. The lateral color of the designed f-theta lens is less than 11 μm within the scan area of 150 mm x 150 mm, which meet the application requirements of dual wavelength selective laser melting.
Digital selective growth of a ZnO nanowire array by large scale laser decomposition of zinc acetate.
Hong, Sukjoon; Yeo, Junyeob; Manorotkul, Wanit; Kang, Hyun Wook; Lee, Jinhwan; Han, Seungyong; Rho, Yoonsoo; Suh, Young Duk; Sung, Hyung Jin; Ko, Seung Hwan
2013-05-07
We develop a digital direct writing method for ZnO NW micro-patterned growth on a large scale by selective laser decomposition of zinc acetate. For ZnO NW growth, by replacing the bulk heating with the scanning focused laser as a fully digital local heat source, zinc acetate crystallites can be selectively activated as a ZnO seed pattern to grow ZnO nanowires locally on a larger area. Together with the selective laser sintering process of metal nanoparticles, more than 10,000 UV sensors have been demonstrated on a 4 cm × 4 cm glass substrate to develop all-solution processible, all-laser mask-less digital fabrication of electronic devices including active layer and metal electrodes without any conventional vacuum deposition, photolithographic process, premade mask, high temperature and vacuum environment.
NASA Astrophysics Data System (ADS)
Zarrabi, Nawid; Clausen, Caterina; Düser, Monika G.; Börsch, Michael
2013-02-01
Conformational changes of individual fluorescently labeled proteins can be followed in solution using a confocal microscope. Two fluorophores attached to selected domains of the protein report fluctuating conformations. Based on Förster resonance energy transfer (FRET) between these fluorophores on a single protein, sequential distance changes between the dyes provide the real time trajectories of protein conformations. However, observation times are limited for freely diffusing biomolecules by Brownian motion through the confocal detection volume. A. E. Cohen and W. E. Moerner have invented and built microfluidic devices with 4 electrodes for an Anti-Brownian Electrokinetic Trap (ABELtrap). Here we present an ABELtrap based on a laser focus pattern generated by a pair of acousto-optical beam deflectors and controlled by a programmable FPGA chip. Fluorescent 20-nm beads in solution were used to mimic freely diffusing large proteins like solubilized FoF1-ATP synthase. The ABELtrap could hold these nanobeads for about 10 seconds at the given position. Thereby, observation times of a single particle were increased by a factor of 1000.
Mineo, Hirobumi; Yamaki, Masahiro; Teranishi, Yoshiaki; Hayashi, Michitoshi; Lin, Sheng Hsien; Fujimura, Yuichi
2012-09-05
Nonplanar chiral aromatic molecules are candidates for use as building blocks of multidimensional switching devices because the π electrons can generate ring currents with a variety of directions. We employed (P)-2,2'-biphenol because four patterns of π-electron rotations along the two phenol rings are possible and theoretically determine how quantum switching of the π-electron rotations can be realized. We found that each rotational pattern can be driven by a coherent excitation of two electronic states under two conditions: one is the symmetry of the electronic states and the other is their relative phase. On the basis of the results of quantum dynamics simulations, we propose a quantum control method for sequential switching among the four rotational patterns that can be performed by using ultrashort overlapped pump and dump pulses with properly selected relative phases and photon polarization directions. The results serve as a theoretical basis for the design of confined ultrafast switching of ring currents of nonplanar molecules and further current-induced magnetic fluxes of more sophisticated systems.
Selective material ablation by the TEA CO2 laser
NASA Astrophysics Data System (ADS)
Sumiyoshi, Tetsumi; Shiratori, Akira; Ninomiya, Yutaka; Obara, Minoru
1995-03-01
This paper reports two topics in the material processing using TEA CO2 lasers. We demonstrated selective ablation of hydrogenated amorphous silicon (a-Si:H) thin layer on a quartz substrate by the second harmonic (SH) radiation of TEA CO2 laser generated by AgGaSe2 nonlinear crystal. Si-H bonds contained in a-Si:H strongly absorb the 5 micrometers SH radiation and resulted in the selective ablation of the a-Si:H layer. The successful ablation processing of ethylenetetrafluoroethylene (ETFE) copolymer by the 9.6 micrometers fundamental wavelength TEA CO2 laser is also reported. Only ETFE thin film adhered to an aluminum substrate can be ablated by the TEA CO2 laser.
ERIC Educational Resources Information Center
John, Phillip
1982-01-01
Selected infrared laser chemistry topics are discussed including carbon dioxide lasers, infrared quanta and molecules, laser-induced chemistry, structural isomerization (laser purification, sensitized reactions, and dielectric breakdown), and fundamental principles of laser isotope separation, focusing on uranium isotope separation. (JN)
NASA Astrophysics Data System (ADS)
Dyu, V. G.; Kisteneva, M. G.; Shandarov, S. M.; Khudyakova, E. S.; Smirnov, S. V.; Kargin, Yu. F.
Changes in the spectral dependences of the optical absorption induced in the bismuth titanium oxide crystal doped by aluminum as a result of sequential exposition to cw laser radiation first with the wavelength λi = 532 nm and then with the longer wavelength λn = 633, 655, 663, 780, 871, or 1064 nm are investigated. Our experiments show that after the short-wavelength exposition to radiation with λi = 532 nm, the optical absorption in the crystal increases, and in the range 470-1000 nm, yields the spectrum whose form is independent of the initial crystal state. The subsequent exposition to longer-wavelength radiation leads to enhanced transmittance of the crystal in the examined spectral range. A maximum decrease of the optical absorption in the crystal is observed upon exposure to radiation with the wavelength λn = 663 nm.
Resonance ionization laser ion sources for on-line isotope separators (invited).
Marsh, B A
2014-02-01
A Resonance Ionization Laser Ion Source (RILIS) is today considered an essential component of the majority of Isotope Separator On Line (ISOL) facilities; there are seven laser ion sources currently operational at ISOL facilities worldwide and several more are under development. The ionization mechanism is a highly element selective multi-step resonance photo-absorption process that requires a specifically tailored laser configuration for each chemical element. For some isotopes, isomer selective ionization may even be achieved by exploiting the differences in hyperfine structures of an atomic transition for different nuclear spin states. For many radioactive ion beam experiments, laser resonance ionization is the only means of achieving an acceptable level of beam purity without compromising isotope yield. Furthermore, by performing element selection at the location of the ion source, the propagation of unwanted radioactivity downstream of the target assembly is reduced. Whilst advances in laser technology have improved the performance and reliability of laser ion sources and broadened the range of suitable commercially available laser systems, many recent developments have focused rather on the laser/atom interaction region in the quest for increased selectivity and/or improved spectral resolution. Much of the progress in this area has been achieved by decoupling the laser ionization from competing ionization processes through the use of a laser/atom interaction region that is physically separated from the target chamber. A new application of gas catcher laser ion source technology promises to expand the capabilities of projectile fragmentation facilities through the conversion of otherwise discarded reaction fragments into high-purity low-energy ion beams. A summary of recent RILIS developments and the current status of laser ion sources worldwide is presented.
Crispino, Antonio; Figliuzzi, Michele Mario; Iovane, Claudio; Del Giudice, Teresa; Lomanno, Simona; Pacifico, Delfina; Fortunato, Leonzio; Del Giudice, Roberto
2015-01-01
Chronic periodontitis affects 47% of adult population over the age of 30. The first phase of periodontal treatment is always represented by scaling and root planning (SRP), that is a causal, non-surgical therapy that recognizes as primary aims the control of bacterial infection and the reduction of periodontal plaque-associated inflammation. Yet, another innovative causal therapy is represented by the irradiation of periodontal pockets with laser. To evaluate the effect of a 940-nm diode laser as an adjunct to SRP in patients affected by periodontitis. Sixty-eight adult patients with moderate-to-severe periodontitis were sequentially enrolled and undergone to periodontal examination (V1) in order to detect gingival index (GI), plaque index (PI) and probing depth (PD). The patients were randomly divided into two groups: the first (n=34) received SRP treatment alone, the control group (n=34) received SRP and 940-nm diode laser therapy. Data were analyzed by Student's t-test, with two tails; for all clinical parameters, both groups reported statistically significant differences compared to basal values (p<0.0001). Both procedures were effective in improving GI, PI and PD, but the use of diode laser was associated with more evident results. Considered the better clinical outcomes, diode laser can be routinely associated with SRP in the treatment of periodontal pockets of patients with moderate-to-severe periodontitis.
A high-resolution full-field range imaging system
NASA Astrophysics Data System (ADS)
Carnegie, D. A.; Cree, M. J.; Dorrington, A. A.
2005-08-01
There exist a number of applications where the range to all objects in a field of view needs to be obtained. Specific examples include obstacle avoidance for autonomous mobile robots, process automation in assembly factories, surface profiling for shape analysis, and surveying. Ranging systems can be typically characterized as being either laser scanning systems where a laser point is sequentially scanned over a scene or a full-field acquisition where the range to every point in the image is simultaneously obtained. The former offers advantages in terms of range resolution, while the latter tend to be faster and involve no moving parts. We present a system for determining the range to any object within a camera's field of view, at the speed of a full-field system and the range resolution of some point laser scans. Initial results obtained have a centimeter range resolution for a 10 second acquisition time. Modifications to the existing system are discussed that should provide faster results with submillimeter resolution.
NASA Astrophysics Data System (ADS)
Daido, Hiroyuki; Abe, Hiroshi; Shobu, Takahisa; Shimomura, Takuya; Tokuhira, Shinnosuke; Takenaka, Yusuke; Furuyama, Takehiro; Nishimura, Akihiko; Uchida, Hirohisa; Ohshima, Takeshi
2015-09-01
Hydrogen storage alloys become more and more important in the fields of electric energy production and stage and automobiles such as Ni-MH batteries. The vacancies introduced in hydrogen absorption alloy by charged particle beams were found to be positive effect on the increase in the initial hydrogen absorption reaction rate in the previous study. The initial reaction rates of hydrogen absorption and desorption of the alloy are one of the important performances to be improved. Here, we report on the characterization of the hydrogen absorption reaction rate directly illuminated by a femtosecond and nanosecond lasers instead of particle beam machines. A laser illuminates the whole surface sequentially on a tip of a few cm square LaNi4.6Al0.4 alloy resulting in significant improvement in the hydrogen absorption reaction rate. For characterization of the surface layer, we perform an x-ray diffraction experiment using a monochromatized intense x-ray beam from SPring-8 synchrotoron machine.
Controllable lasing performance in solution-processed organic-inorganic hybrid perovskites.
Kao, Tsung Sheng; Chou, Yu-Hsun; Hong, Kuo-Bin; Huang, Jiong-Fu; Chou, Chun-Hsien; Kuo, Hao-Chung; Chen, Fang-Chung; Lu, Tien-Chang
2016-11-03
Solution-processed organic-inorganic perovskites are fascinating due to their remarkable photo-conversion efficiency and great potential in the cost-effective, versatile and large-scale manufacturing of optoelectronic devices. In this paper, we demonstrate that the perovskite nanocrystal sizes can be simply controlled by manipulating the precursor solution concentrations in a two-step sequential deposition process, thus achieving the feasible tunability of excitonic properties and lasing performance in hybrid metal-halide perovskites. The lasing threshold is at around 230 μJ cm -2 in this solution-processed organic-inorganic lead-halide material, which is comparable to the colloidal quantum dot lasers. The efficient stimulated emission originates from the multiple random scattering provided by the micro-meter scale rugged morphology and polycrystalline grain boundaries. Thus the excitonic properties in perovskites exhibit high correlation with the formed morphology of the perovskite nanocrystals. Compared to the conventional lasers normally serving as a coherent light source, the perovskite random lasers are promising in making low-cost thin-film lasing devices for flexible and speckle-free imaging applications.
Habboub, Ghaith; Sharma, Mayur; Barnett, Gene H; Mohammadi, Alireza M
2017-01-01
Minimally-invasive approaches are attractive alternative to standard craniotomy for large intracranial tumors with potentially lesser morbidity. In this report, we describe a sequential combination of two minimally-invasive surgical techniques to treat a large intracranial tumor. A 49year-old woman presented with a history of breast cancer and large left parietal metastasis with significant perilesional edema. This was initially managed by whole brain radiation therapy and stereotactic radiosurgery. The patient underwent laser ablation of the tumor followed by internal tumor debulking using an exoscopic-assisted tubular retractor system. Post-operative MRI showed gross total coverage of the tumor by laser ablation and alleviation of mass effect. The patient recovered well and discharged on second postoperative day. The minimally-invasive combination of laser ablation followed by internal debulking using a tubular retractor device could be done safely and effectively as a minimally invasive alternative to standard craniotomy for large intracranial tumors. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Eggins, S. M.; Kinsley, L. P. J.; Shelley, J. M. G.
1998-05-01
We have used an ArF excimer laser coupled to a quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for the measurement of a range of elements during excavation of a deepening ablation pit in a synthetic glass (NIST 612). Analyte behaviour shows progressive volatile element enrichment at shallow hole depths, with a change to refractory element enrichment as the ablation pit deepens further. Examination of ablation pit morphology and the surface condensate deposited around the ablation site reveals the importance of sequential condensation of refractory, then volatile phases from the cooling plasma plume after the end of the laser pulse. We interpret the observed element fractionation behaviour to reflect a change in ablation processes from photothermal dominated to plasma dominated mechanisms. The development of the surface deposit is greatly reduced by ablating in an ambient atmosphere of He instead of Ar and is accompanied by a two- to four-fold increase in ICP-MS sensitivity.
Halim, Mohammad A; Clavier, Christian; Dagany, Xavier; Kerleroux, Michel; Dugourd, Philippe; Dunbar, Robert C; Antoine, Rodolphe
2018-05-07
In this study, we report the unimolecular dissociation mechanism of megadalton SO 3 -containing poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (PAMPS) polymer cations and anions with the aid of infrared multiphoton dissociation coupled to charge detection ion trap mass spectrometry. A gated electrostatic ion trap ("Benner trap") is used to store and detect single gaseous polymer ions generated by positive and negative polarity in an electrospray ionization source. The trapped ions are then fragmented due to the sequential absorption of multiple infrared photons produced from a continuous-wave CO 2 laser. Several fragmentation pathways having distinct signatures are observed. Highly charged parent ions characteristically adopt a distinctive "stair-case" pattern (assigned to the "fission" process) whereas low charge species take on a "funnel like" shape (assigned to the "evaporation" process). Also, the log-log plot of the dissociation rate constants as a function of laser intensity between PAMPS positive and negative ions is significantly different.
Fakharuddin, Azhar; Palma, Alessandro L; Di Giacomo, Francesco; Casaluci, Simone; Matteocci, Fabio; Wali, Qamar; Rauf, Muhammad; Di Carlo, Aldo; Brown, Thomas M; Jose, Rajan
2015-12-11
The past few years have witnessed remarkable progress in solution-processed methylammonium lead halide (CH3NH3PbX3, X = halide) perovskite solar cells (PSCs) with reported photoconversion efficiency (η) exceeding 20% in laboratory-scale devices and reaching up to 13% in their large area perovskite solar modules (PSMs). These devices mostly employ mesoporous TiO2 nanoparticles (NPs) as an electron transport layer (ETL) which provides a scaffold on which the perovskite semiconductor can grow. However, limitations exist which are due to trap-limited electron transport and non-complete pore filling. Herein, we have employed TiO2 nanorods (NRs), a material offering a two-fold higher electronic mobility and higher pore-filing compared to their particle analogues, as an ETL. A crucial issue in NRs' patterning over substrates is resolved by using precise Nd:YVO4 laser ablation, and a champion device with η ∼ 8.1% is reported via a simple and low cost vacuum-vapor assisted sequential processing (V-VASP) of a CH3NH3PbI3 film. Our experiments showed a successful demonstration of NRs-based PSMs via the V-VASP technique which can be applied to fabricate large area modules with a pin-hole free, smooth and dense perovskite layer which is required to build high efficiency devices.
Selective laser ionisation of radionuclide 63Ni
NASA Astrophysics Data System (ADS)
Tsvetkov, G. O.; D'yachkov, A. B.; Gorkunov, A. A.; Labozin, A. V.; Mironov, S. M.; Firsov, V. A.; Panchenko, V. Ya.
2017-02-01
We report a search for a scheme of selective laser stepwise ionisation of radionuclide 63Ni by radiation of a dye laser pumped by a copper vapour laser. A three-stage scheme is found with ionisation through an autoionising state (AIS): 3d 84s2 3F4(E = 0) → 3d 94p 1Fo3(31030.99 cm-1) → 3d 94d 2[7/2]4(49322.56 cm-1) → AIS(67707.61 cm-1) which, by employing saturated radiation intensities provides the ionisation selectivity of above 1200 for 63Ni.
Huang, Yimei; Lui, Harvey; Zhao, Jianhua; Wu, Zhenguo; Zeng, Haishan
2017-01-01
The successful application of lasers in the treatment of skin diseases and cosmetic surgery is largely based on the principle of conventional selective photothermolysis which relies strongly on the difference in the absorption between the therapeutic target and its surroundings. However, when the differentiation in absorption is not sufficient, collateral damage would occur due to indiscriminate and nonspecific tissue heating. To deal with such cases, we introduce a novel spatially selective photothermolysis method based on multiphoton absorption in which the radiant energy of a tightly focused near-infrared femtosecond laser beam can be directed spatially by aiming the laser focal point to the target of interest. We construct a multimodal optical microscope to perform and monitor the spatially selective photothermolysis. We demonstrate that precise alteration of the targeted tissue is achieved while leaving surrounding tissue intact by choosing appropriate femtosecond laser exposure with multimodal optical microscopy monitoring in real time.
Huang, Yimei; Lui, Harvey; Zhao, Jianhua; Wu, Zhenguo; Zeng, Haishan
2017-01-01
The successful application of lasers in the treatment of skin diseases and cosmetic surgery is largely based on the principle of conventional selective photothermolysis which relies strongly on the difference in the absorption between the therapeutic target and its surroundings. However, when the differentiation in absorption is not sufficient, collateral damage would occur due to indiscriminate and nonspecific tissue heating. To deal with such cases, we introduce a novel spatially selective photothermolysis method based on multiphoton absorption in which the radiant energy of a tightly focused near-infrared femtosecond laser beam can be directed spatially by aiming the laser focal point to the target of interest. We construct a multimodal optical microscope to perform and monitor the spatially selective photothermolysis. We demonstrate that precise alteration of the targeted tissue is achieved while leaving surrounding tissue intact by choosing appropriate femtosecond laser exposure with multimodal optical microscopy monitoring in real time. PMID:28255346
Collaborative Filtering Based on Sequential Extraction of User-Item Clusters
NASA Astrophysics Data System (ADS)
Honda, Katsuhiro; Notsu, Akira; Ichihashi, Hidetomo
Collaborative filtering is a computational realization of “word-of-mouth” in network community, in which the items prefered by “neighbors” are recommended. This paper proposes a new item-selection model for extracting user-item clusters from rectangular relation matrices, in which mutual relations between users and items are denoted in an alternative process of “liking or not”. A technique for sequential co-cluster extraction from rectangular relational data is given by combining the structural balancing-based user-item clustering method with sequential fuzzy cluster extraction appraoch. Then, the tecunique is applied to the collaborative filtering problem, in which some items may be shared by several user clusters.
NASA Astrophysics Data System (ADS)
Li, Xiaowei; Xie, Qian; Jiang, Lan; Han, Weina; Wang, Qingsong; Wang, Andong; Hu, Jie; Lu, Yongfeng
2017-05-01
In this study, silicon micro/nanostructures of controlled size and shape are fabricated by chemical-etching-assisted femtosecond laser single-pulse irradiation, which is a flexible, high-throughput method. The pulse fluence is altered to create various laser printing patterns for the etching mask, resulting in the sequential evolution of three distinct surface micro/nanostructures, namely, ring-like microstructures, flat-top pillar microstructures, and spike nanostructures. The characterized diameter of micro/nanostructures reveals that they can be flexibly tuned from the micrometer (˜2 μm) to nanometer (˜313 nm) scales by varying the laser pulse fluence in a wide range. Micro-Raman spectroscopy and transmission electron microscopy are utilized to demonstrate that the phase state changes from single-crystalline silicon (c-Si) to amorphous silicon (a-Si) after single-pulse femtosecond laser irradiation. This amorphous layer with a lower etching rate then acts as a mask in the wet etching process. Meanwhile, the on-the-fly punching technique enables the efficient fabrication of large-area patterned surfaces on the centimeter scale. This study presents a highly efficient method of controllably manufacturing silicon micro/nanostructures with different single-pulse patterns, which has promising applications in the photonic, solar cell, and sensors fields.
Mass-Selective Laser Photoionization.
ERIC Educational Resources Information Center
Smalley, R. E.
1982-01-01
Discusses the nature and applications of mass-selective laser photoionization. The ionization can be done with a single intense laser pulse lasting a few billionths of a second with no molecular fragmentation. Applications focus on: (1) benzene clusters, excimers, and exciplexes; (2) metal clusters; and (3) triplet formation and decay. (Author/JN)
MotieGhader, Habib; Gharaghani, Sajjad; Masoudi-Sobhanzadeh, Yosef; Masoudi-Nejad, Ali
2017-01-01
Feature selection is of great importance in Quantitative Structure-Activity Relationship (QSAR) analysis. This problem has been solved using some meta-heuristic algorithms such as GA, PSO, ACO and so on. In this work two novel hybrid meta-heuristic algorithms i.e. Sequential GA and LA (SGALA) and Mixed GA and LA (MGALA), which are based on Genetic algorithm and learning automata for QSAR feature selection are proposed. SGALA algorithm uses advantages of Genetic algorithm and Learning Automata sequentially and the MGALA algorithm uses advantages of Genetic Algorithm and Learning Automata simultaneously. We applied our proposed algorithms to select the minimum possible number of features from three different datasets and also we observed that the MGALA and SGALA algorithms had the best outcome independently and in average compared to other feature selection algorithms. Through comparison of our proposed algorithms, we deduced that the rate of convergence to optimal result in MGALA and SGALA algorithms were better than the rate of GA, ACO, PSO and LA algorithms. In the end, the results of GA, ACO, PSO, LA, SGALA, and MGALA algorithms were applied as the input of LS-SVR model and the results from LS-SVR models showed that the LS-SVR model had more predictive ability with the input from SGALA and MGALA algorithms than the input from all other mentioned algorithms. Therefore, the results have corroborated that not only is the predictive efficiency of proposed algorithms better, but their rate of convergence is also superior to the all other mentioned algorithms. PMID:28979308
MotieGhader, Habib; Gharaghani, Sajjad; Masoudi-Sobhanzadeh, Yosef; Masoudi-Nejad, Ali
2017-01-01
Feature selection is of great importance in Quantitative Structure-Activity Relationship (QSAR) analysis. This problem has been solved using some meta-heuristic algorithms such as GA, PSO, ACO and so on. In this work two novel hybrid meta-heuristic algorithms i.e. Sequential GA and LA (SGALA) and Mixed GA and LA (MGALA), which are based on Genetic algorithm and learning automata for QSAR feature selection are proposed. SGALA algorithm uses advantages of Genetic algorithm and Learning Automata sequentially and the MGALA algorithm uses advantages of Genetic Algorithm and Learning Automata simultaneously. We applied our proposed algorithms to select the minimum possible number of features from three different datasets and also we observed that the MGALA and SGALA algorithms had the best outcome independently and in average compared to other feature selection algorithms. Through comparison of our proposed algorithms, we deduced that the rate of convergence to optimal result in MGALA and SGALA algorithms were better than the rate of GA, ACO, PSO and LA algorithms. In the end, the results of GA, ACO, PSO, LA, SGALA, and MGALA algorithms were applied as the input of LS-SVR model and the results from LS-SVR models showed that the LS-SVR model had more predictive ability with the input from SGALA and MGALA algorithms than the input from all other mentioned algorithms. Therefore, the results have corroborated that not only is the predictive efficiency of proposed algorithms better, but their rate of convergence is also superior to the all other mentioned algorithms.
Clock Technology Development for the Laser Cooling and Atomic Physics (LCAP) Program
NASA Technical Reports Server (NTRS)
Klipstein, W. M.; Thompson, R. J.; Seidel, D. J.; Kohel, J.; Maleki, L.
1998-01-01
The Time and Frequency Sciences and Technology Group at Jet Propulsion Laboratory (JPL) has developed a laser cooling capability for flight and has been selected by NASA to support the Laser-Cooling and Atomic Physics (LCAP) program. Current work in the group includes design and development for tee two laser-cooled atomic clock experiments which have been selected for flight on the International Space Station.
Selective laser vaporization of polypropylene sutures and mesh
NASA Astrophysics Data System (ADS)
Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.
2012-02-01
Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.
NASA Astrophysics Data System (ADS)
Tsai, Ko-Fan; Chu, Shu-Chun
2018-03-01
This study proposes a complete and unified method for selective excitation of any specified nearly nondiffracting Helmholtz-Gauss (HzG) beam in end-pumped solid-state digital lasers. Four types of the HzG beams: cosine-Gauss beams, Bessel-Gauss beams, Mathieu-Gauss beams, and, in particular, parabolic-Gauss beams are successfully demonstrated to be generated with the proposed methods. To the best of the authors’ knowledge, parabolic-Gauss beams have not yet been directly generated from any kind of laser system. The numerical results of this study show that one can successfully achieve any lasing HzG beams directly from the solid-state digital lasers with only added control of the laser gain transverse position provided by off-axis end pumping. This study also presents a practical digital laser set-up for easily manipulating off-axis pumping in order to achieve the control of the laser gain transverse gain position in digital lasers. The reported results in this study provide advancement of digital lasers in dynamically generating nondiffracting beams. The control of the digital laser cavity gain position creates the possibility of achieving real-time selection of more laser modes in digital lasers, and it is worth further investigation in the future.
Retinal response of Macaca mulatta to picosecond laser pulses of varying energy and spot size.
Roach, William P; Cain, Clarence P; Narayan, Drew G; Noojin, Gary D; Boppart, Stephen A; Birngruber, Reginald; Fujimoto, James G; Toth, Cynthia A
2004-01-01
We investigate the relationship between the laser beam at the retina (spot size) and the extent of retinal injury from single ultrashort laser pulses. From previous studies it is believed that the retinal effect of single 3-ps laser pulses should vary in extent and location, depending on the occurrence of laser-induced breakdown (LIB) at the site of laser delivery. Single 3-ps pulses of 580-nm laser energy are delivered over a range of spot sizes to the retina of Macaca mulatta. The retinal response is captured sequentially with optical coherence tomography (OCT). The in vivo OCT images and the extent of pathology on final microscopic sections of the laser site are compared. With delivery of a laser pulse with peak irradiance greater than that required for LIB, OCT and light micrographs demonstrate inner retinal injury with many intraretinal and/or vitreous hemorrhages. In contrast, broad outer retinal injury with minimal to no choriocapillaris effect is seen after delivery of laser pulses to a larger retinal area (60 to 300 microm diam) when peak irradiance is less than that required for LIB. The broader lesions extend into the inner retina when higher energy delivery produces intraretinal injury. Microscopic examination of stained fixed tissues provide better resolution of retinal morphology than OCT. OCT provides less resolution but could be guided over an in vivo, visible retinal lesion for repeated sampling over time during the evolution of the lesion formation. For 3-ps visible wavelength laser pulses, varying the spot size and laser energy directly affects the extent of retinal injury. This again is believed to be partly due to the onset of LIB, as seen in previous studies. Spot-size dependence should be considered when comparing studies of retinal effects or when pursuing a specific retinal effect from ultrashort laser pulses. Copyright 2004 Society of Photo-Optical Instrumentation Engineers.
Scalable Creation of Long-Lived Multipartite Entanglement
NASA Astrophysics Data System (ADS)
Kaufmann, H.; Ruster, T.; Schmiegelow, C. T.; Luda, M. A.; Kaushal, V.; Schulz, J.; von Lindenfels, D.; Schmidt-Kaler, F.; Poschinger, U. G.
2017-10-01
We demonstrate the deterministic generation of multipartite entanglement based on scalable methods. Four qubits are encoded in 40Ca+, stored in a microstructured segmented Paul trap. These qubits are sequentially entangled by laser-driven pairwise gate operations. Between these, the qubit register is dynamically reconfigured via ion shuttling operations, where ion crystals are separated and merged, and ions are moved in and out of a fixed laser interaction zone. A sequence consisting of three pairwise entangling gates yields a four-ion Greenberger-Horne-Zeilinger state |ψ ⟩=(1 /√{2 })(|0000 ⟩+|1111 ⟩) , and full quantum state tomography reveals a state fidelity of 94.4(3)%. We analyze the decoherence of this state and employ dynamic decoupling on the spatially distributed constituents to maintain 69(5)% coherence at a storage time of 1.1 sec.
Parameters in selective laser melting for processing metallic powders
NASA Astrophysics Data System (ADS)
Kurzynowski, Tomasz; Chlebus, Edward; Kuźnicka, Bogumiła; Reiner, Jacek
2012-03-01
The paper presents results of studies on Selective Laser Melting. SLM is an additive manufacturing technology which may be used to process almost all metallic materials in the form of powder. Types of energy emission sources, mainly fiber lasers and/or Nd:YAG laser with similar characteristics and the wavelength of 1,06 - 1,08 microns, are provided primarily for processing metallic powder materials with high absorption of laser radiation. The paper presents results of selected variable parameters (laser power, scanning time, scanning strategy) and fixed parameters such as the protective atmosphere (argon, nitrogen, helium), temperature, type and shape of the powder material. The thematic scope is very broad, so the work was focused on optimizing the process of selective laser micrometallurgy for producing fully dense parts. The density is closely linked with other two conditions: discontinuity of the microstructure (microcracks) and stability (repeatability) of the process. Materials used for the research were stainless steel 316L (AISI), tool steel H13 (AISI), and titanium alloy Ti6Al7Nb (ISO 5832-11). Studies were performed with a scanning electron microscope, a light microscopes, a confocal microscope and a μCT scanner.
Professional Orchestral Conductors' Use of Selected Teaching Behaviors in Rehearsal
ERIC Educational Resources Information Center
Whitaker, Jennifer A.
2017-01-01
This descriptive study examined professional conductors' use of rehearsal time in sequential pattern components, discussing task presentation targets, and using verbal imagery and modeling techniques. Commercially available videos of 15 professional conductors rehearsing prominent orchestras were scripted, coded, and timed for selected teaching…
Psychological Principles in Materials Selection.
ERIC Educational Resources Information Center
Colvin, Cynthia M.
Those psychological principles which might aid the teacher in the selection of instructional materials are examined. Since learning is a process which builds sequentially on past learning, beginning reading materials should include words that have personal relevance for the individual child. Meaningful material is learned more quickly than…
NASA Astrophysics Data System (ADS)
He, Hong-Sen; Zhang, Ming-Ming; Dong, Jun; Ueda, Ken-Ichi
2016-12-01
A tilted, linearly polarized laser diode end-pumped Cr4+:YAG passively Q-switched a-cut Nd:YVO4 microchip laser for generating numerous Ince-Gaussian (IG) laser modes with controllable orientations has been demonstrated by selecting the crystalline orientation of an a-cut Nd:YVO4 crystal. The same IG laser mode with different orientations has been achieved with the same absorbed pump power in a passively Q-switched Nd:YVO4 microchip laser under linearly polarized pumping when the incident pump power and the crystalline orientation of an a-cut Nd:YVO4 crystal are both properly selected. The significant improvement of pulsed laser performance of controllable IG modes has been achieved by selecting the crystalline orientation of an a-cut Nd:YVO4 crystal. The maximum pulse energy is obtained along the a-axis of an a-cut Nd:YVO4 crystal and the highest peak power is achieved along the c-axis of an a-cut Nd:YVO4 crystal, respectively, which has potential applications on quantum computation and optical manipulation. The generation of controllable IG laser modes in microchip lasers under linearly polarized pumping provides a convenient and universal way to control IG laser mode numbers with anisotropic crystal as a gain medium.
Effectiveness of CO2 laser with subcision in patients with acne scars.
Anupama, Y G; Wahab, Afthab Jameela
2016-11-01
Post-acne facial scarring has always been a challenge to treat. It requires multiple therapeutic modalities as single modality is not hundred percent effective. Therefore, we have combined CO 2 laser resurfacing with subcision in patients with acne scars for better results. The aim is to study the effectiveness and side effects of CO 2 laser with subcision in patients with atrophic acne scars. Fifty patients were selected for the study. Baseline grading was done with Goodman and Baron grading system. Twenty-five patients were randomly selected for subcision followed by CO 2 laser and the remaining patients were selected for CO 2 laser alone. The treatment was done for four sessions at 4-week interval. Clinical photographs were obtained for evaluation. CO 2 laser with subcision showed excellent response in grade-2 and -3 acne scars. Statistically there is a significant difference between CO 2 laser following subcision and CO 2 laser alone at 5% level (p < 0.05). Both procedures were well tolerated with minimal side effects. The highly versatile CO 2 laser is useful for treating acne scars. Subcision prior to the CO 2 laser procedure showed better improvement when compared to CO 2 laser alone. Thus, in acne scars, multiple therapeutic modalities achieve better results.
Amino acid selective unlabeling for sequence specific resonance assignments in proteins
Krishnarjuna, B.; Jaipuria, Garima; Thakur, Anushikha
2010-01-01
Sequence specific resonance assignment constitutes an important step towards high-resolution structure determination of proteins by NMR and is aided by selective identification and assignment of amino acid types. The traditional approach to selective labeling yields only the chemical shifts of the particular amino acid being selected and does not help in establishing a link between adjacent residues along the polypeptide chain, which is important for sequential assignments. An alternative approach is the method of amino acid selective ‘unlabeling’ or reverse labeling, which involves selective unlabeling of specific amino acid types against a uniformly 13C/15N labeled background. Based on this method, we present a novel approach for sequential assignments in proteins. The method involves a new NMR experiment named, {12COi–15Ni+1}-filtered HSQC, which aids in linking the 1HN/15N resonances of the selectively unlabeled residue, i, and its C-terminal neighbor, i + 1, in HN-detected double and triple resonance spectra. This leads to the assignment of a tri-peptide segment from the knowledge of the amino acid types of residues: i − 1, i and i + 1, thereby speeding up the sequential assignment process. The method has the advantage of being relatively inexpensive, applicable to 2H labeled protein and can be coupled with cell-free synthesis and/or automated assignment approaches. A detailed survey involving unlabeling of different amino acid types individually or in pairs reveals that the proposed approach is also robust to misincorporation of 14N at undesired sites. Taken together, this study represents the first application of selective unlabeling for sequence specific resonance assignments and opens up new avenues to using this methodology in protein structural studies. Electronic supplementary material The online version of this article (doi:10.1007/s10858-010-9459-z) contains supplementary material, which is available to authorized users. PMID:21153044
NASA Astrophysics Data System (ADS)
Kim, Charlton C.; Wallace, Vincent P.; Rasouli, Alexandre; Coleno, Mariah L.; Dao, Xavier; Tromberg, Bruce J.; Wong, Brian J.
2000-05-01
Laser irradiation of hyaline cartilage result in stable shape changes due to temperature dependent stress relaxation. In this study, we determined the structural changes in chondrocytes within porcine nasal septal cartilage tissue over a 4-day period using a two-photon laser scanning microscope (TPM) following Nd:YAG laser irradiation (lambda equals 1.32 micrometer) using parameters that result in mechanical stress relaxation (6.0 W, 5.4 mm spot diameter). TPM excitation (780 nm) result in induction of fluorescence from endogenous agents such as NADH, NADPH, and flavoproteins in the 400 - 500 nm spectral region. During laser irradiation diffuse reflectance (from a probe HeNe laser, (lambda) equals 632.8 nm), surface temperature, and stress relaxation were measured dynamically. Each specimen received one, two, or three sequential laser exposures (average irradiation times of 5, 6, and 8 seconds). The cartilage reached a peak surface temperature of about 70 degrees Celsius during irradiation. Cartilage denatured in 50% EtOH (20 minutes) was used as a positive control. TPM was performed using a mode-locked 780 nm Titanium:Sapphire (Ti:Al203) beam with a, 63X, 1.2 N.A. water immersion objective (working distance of 200 mm) to detect the fluorescence emission from the chondrocytes. Images of chondrocytes were obtained at depths up to 150 microns (lateral resolution equals 35 micrometer X 35 micrometer). Images were obtained immediately following laser exposure, and also after 4 days in culture. In both cases, the irradiated and non-irradiated specimens do not show any discernible difference in general shape or auto fluorescence. In contrast, positive controls (immersed in 50% ethanol), show markedly increased fluorescence relative to both the native and irradiated specimens, in the cytoplasmic region.
Taking Advantage of Selective Change Driven Processing for 3D Scanning
Vegara, Francisco; Zuccarello, Pedro; Boluda, Jose A.; Pardo, Fernando
2013-01-01
This article deals with the application of the principles of SCD (Selective Change Driven) vision to 3D laser scanning. Two experimental sets have been implemented: one with a classical CMOS (Complementary Metal-Oxide Semiconductor) sensor, and the other one with a recently developed CMOS SCD sensor for comparative purposes, both using the technique known as Active Triangulation. An SCD sensor only delivers the pixels that have changed most, ordered by the magnitude of their change since their last readout. The 3D scanning method is based on the systematic search through the entire image to detect pixels that exceed a certain threshold, showing the SCD approach to be ideal for this application. Several experiments for both capturing strategies have been performed to try to find the limitations in high speed acquisition/processing. The classical approach is limited by the sequential array acquisition, as predicted by the Nyquist–Shannon sampling theorem, and this has been experimentally demonstrated in the case of a rotating helix. These limitations are overcome by the SCD 3D scanning prototype achieving a significantly higher performance. The aim of this article is to compare both capturing strategies in terms of performance in the time and frequency domains, so they share all the static characteristics including resolution, 3D scanning method, etc., thus yielding the same 3D reconstruction in static scenes. PMID:24084110
Movement plans for posture selection do not transfer across hands
Schütz, Christoph; Schack, Thomas
2015-01-01
In a sequential task, the grasp postures people select depend on their movement history. This motor hysteresis effect results from the reuse of former movement plans and reduces the cognitive cost of movement planning. Movement plans for hand trajectories not only transfer across successive trials, but also across hands. We therefore asked whether such a transfer would also be found in movement plans for hand postures. To this end, we designed a sequential, continuous posture selection task. Participants had to open a column of drawers with cylindrical knobs in ascending and descending sequences. A hand switch was required in each sequence. Hand pro/supination was analyzed directly before and after the hand switch. Results showed that hysteresis effects were present directly before, but absent directly after the hand switch. This indicates that, in the current study, movement plans for hand postures only transfer across trials, but not across hands. PMID:26441734
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarov, G N; Petin, A N
2016-03-31
We report the results of studies on the isotope-selective infrared multiphoton dissociation (IR MFD) of SF{sub 6} and CF{sub 3}I molecules in a pulsed, gas-dynamically cooled molecular flow interacting with a solid surface. The productivity of this method in the conditions of a specific experiment (by the example of SF{sub 6} molecules) is evaluated. A number of low-energy methods of molecular laser isotope separation based on the use of infrared lasers for selective excitation of molecules are analysed and their productivity is estimated. The methods are compared with those of selective dissociation of molecules in the flow interacting with amore » surface. The advantages of this method compared to the low-energy methods of molecular laser isotope separation and the IR MPD method in the unperturbed jets and flows are shown. It is concluded that this method could be a promising alternative to the low-energy methods of molecular laser isotope separation. (laser separation of isotopes)« less
NASA Astrophysics Data System (ADS)
Cannon, B. D.
1993-10-01
Isotopically-selective excitation of uranium atoms by diode lasers can be the basis for a portable instrument to perform uranium isotopic assays in the field. Such an instrument would improve the ability of on-site inspections to detect and deter nuclear proliferation. Published and unpublished spectroscopic data on atomic uranium were examined to identify candidate transitions for isotopically-selective laser excitation with diode lasers. Eleven candidate transitions were identified and evaluated for their potential usefulness for a portable uranium assay instrument. Eight of these transitions are suitable for laser induced fluorescence using different excitation and detection wavelengths, which will improve sensitivity and elemental selectivity. Data sheets on the 25 uranium transitions in the wavelength range 629 nm to 1,000 nm that originate in the ground or first excited states of neutral atomic uranium are included. Each data sheet provides the wavelength, upper and lower energy levels, angular momentum quantum numbers, U-235 isotope shift (relative to U-238, and high-resolution spectra of weapons-grade uranium (93% U-235 and 7% U-238).
Qualification and Selection of Flight Diode Lasers for Space Applications
NASA Technical Reports Server (NTRS)
Liebe, Carl C.; Dillon, Robert P.; Gontijo, Ivair; Forouhar, Siamak; Shapiro, Andrew A.; Cooper, Mark S.; Meras, Patrick L.
2010-01-01
The reliability and lifetime of laser diodes is critical to space missions. The Nuclear Spectroscopic Telescope Array (NuSTAR) mission includes a metrology system that is based upon laser diodes. An operational test facility has been developed to qualify and select, by mission standards, laser diodes that will survive the intended space environment and mission lifetime. The facility is situated in an electrostatic discharge (ESD) certified clean-room and consist of an enclosed temperature-controlled stage that can accommodate up to 20 laser diodes. The facility is designed to characterize a single laser diode, in addition to conducting laser lifetime testing on up to 20 laser diodes simultaneously. A standard laser current driver is used to drive a single laser diode. Laser diode current, voltage, power, and wavelength are measured for each laser diode, and a method of selecting the most adequate laser diodes for space deployment is implemented. The method consists of creating histograms of laser threshold currents, powers at a designated current, and wavelengths at designated power. From these histograms, the laser diodes that illustrate a performance that is outside the normal are rejected and the remaining lasers are considered spaceborne candidates. To perform laser lifetime testing, the facility is equipped with 20 custom laser drivers that were designed and built by California Institute of Technology specifically to drive NuSTAR metrology lasers. The laser drivers can be operated in constant-current mode or alternating-current mode. Situated inside the enclosure, in front of the laser diodes, are 20 power-meter heads to record laser power throughout the duration of lifetime testing. Prior to connecting a laser diode to the current source for characterization and lifetime testing, a background program is initiated to collect current, voltage, and resistance. This backstage data collection enables the operational test facility to have full laser diode traceablity.
A behavioural and neural evaluation of prospective decision-making under risk
Symmonds, Mkael; Bossaerts, Peter; Dolan, Raymond J.
2010-01-01
Making the best choice when faced with a chain of decisions requires a person to judge both anticipated outcomes and future actions. Although economic decision-making models account for both risk and reward in single choice contexts there is a dearth of similar knowledge about sequential choice. Classical utility-based models assume that decision-makers select and follow an optimal pre-determined strategy, irrespective of the particular order in which options are presented. An alternative model involves continuously re-evaluating decision utilities, without prescribing a specific future set of choices. Here, using behavioral and functional magnetic resonance imaging (fMRI) data, we studied human subjects in a sequential choice task and use these data to compare alternative decision models of valuation and strategy selection. We provide evidence that subjects adopt a model of re-evaluating decision utilities, where available strategies are continuously updated and combined in assessing action values. We validate this model by using simultaneously-acquired fMRI data to show that sequential choice evokes a pattern of neural response consistent with a tracking of anticipated distribution of future reward, as expected in such a model. Thus, brain activity evoked at each decision point reflects the expected mean, variance and skewness of possible payoffs, consistent with the idea that sequential choice evokes a prospective evaluation of both available strategies and possible outcomes. PMID:20980595
Park, Henry S; Gross, Cary P; Makarov, Danil V; Yu, James B
2012-08-01
To evaluate the influence of immortal time bias on observational cohort studies of postoperative radiotherapy (PORT) and the effectiveness of sequential landmark analysis to account for this bias. First, we reviewed previous studies of the Surveillance, Epidemiology, and End Results (SEER) database to determine how frequently this bias was considered. Second, we used SEER to select three tumor types (glioblastoma multiforme, Stage IA-IVM0 gastric adenocarcinoma, and Stage II-III rectal carcinoma) for which prospective trials demonstrated an improvement in survival associated with PORT. For each tumor type, we calculated conditional survivals and adjusted hazard ratios of PORT vs. postoperative observation cohorts while restricting the sample at sequential monthly landmarks. Sixty-two percent of previous SEER publications evaluating PORT failed to use a landmark analysis. As expected, delivery of PORT for all three tumor types was associated with improved survival, with the largest associated benefit favoring PORT when all patients were included regardless of survival. Preselecting a cohort with a longer minimum survival sequentially diminished the apparent benefit of PORT. Although the majority of previous SEER articles do not correct for it, immortal time bias leads to altered estimates of PORT effectiveness, which are very sensitive to landmark selection. We suggest the routine use of sequential landmark analysis to account for this bias. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Henry S.; Gross, Cary P.; Makarov, Danil V.
2012-08-01
Purpose: To evaluate the influence of immortal time bias on observational cohort studies of postoperative radiotherapy (PORT) and the effectiveness of sequential landmark analysis to account for this bias. Methods and Materials: First, we reviewed previous studies of the Surveillance, Epidemiology, and End Results (SEER) database to determine how frequently this bias was considered. Second, we used SEER to select three tumor types (glioblastoma multiforme, Stage IA-IVM0 gastric adenocarcinoma, and Stage II-III rectal carcinoma) for which prospective trials demonstrated an improvement in survival associated with PORT. For each tumor type, we calculated conditional survivals and adjusted hazard ratios of PORTmore » vs. postoperative observation cohorts while restricting the sample at sequential monthly landmarks. Results: Sixty-two percent of previous SEER publications evaluating PORT failed to use a landmark analysis. As expected, delivery of PORT for all three tumor types was associated with improved survival, with the largest associated benefit favoring PORT when all patients were included regardless of survival. Preselecting a cohort with a longer minimum survival sequentially diminished the apparent benefit of PORT. Conclusions: Although the majority of previous SEER articles do not correct for it, immortal time bias leads to altered estimates of PORT effectiveness, which are very sensitive to landmark selection. We suggest the routine use of sequential landmark analysis to account for this bias.« less
A behavioral and neural evaluation of prospective decision-making under risk.
Symmonds, Mkael; Bossaerts, Peter; Dolan, Raymond J
2010-10-27
Making the best choice when faced with a chain of decisions requires a person to judge both anticipated outcomes and future actions. Although economic decision-making models account for both risk and reward in single-choice contexts, there is a dearth of similar knowledge about sequential choice. Classical utility-based models assume that decision-makers select and follow an optimal predetermined strategy, regardless of the particular order in which options are presented. An alternative model involves continuously reevaluating decision utilities, without prescribing a specific future set of choices. Here, using behavioral and functional magnetic resonance imaging (fMRI) data, we studied human subjects in a sequential choice task and use these data to compare alternative decision models of valuation and strategy selection. We provide evidence that subjects adopt a model of reevaluating decision utilities, in which available strategies are continuously updated and combined in assessing action values. We validate this model by using simultaneously acquired fMRI data to show that sequential choice evokes a pattern of neural response consistent with a tracking of anticipated distribution of future reward, as expected in such a model. Thus, brain activity evoked at each decision point reflects the expected mean, variance, and skewness of possible payoffs, consistent with the idea that sequential choice evokes a prospective evaluation of both available strategies and possible outcomes.
Inert gas enhanced laser-assisted purification of platinum electron-beam-induced deposits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanford, Michael G.; Lewis, Brett B.; Noh, Joo Hyon
Electron-beam-induced deposition patterns, with composition of PtC 5, were purified using a pulsed laser-induced purification reaction to erode the amorphous carbon matrix and form pure platinum deposits. Enhanced mobility of residual H 2O molecules via a localized injection of inert Ar–H 2 (4%) is attributed to be the reactive gas species for purification of the deposits. Surface purification of deposits was realized at laser exposure times as low as 0.1 s. The ex situ purification reaction in the deposit interior was shown to be rate-limited by reactive gas diffusion into the deposit, and deposit contraction associated with the purification processmore » caused some loss of shape retention. To circumvent the intrinsic flaws of the ex situ anneal process, in situ deposition and purification techniques were explored that resemble a direct write atomic layer deposition (ALD) process. First, we explored a laser-assisted electron-beam-induced deposition (LAEBID) process augmented with reactive gas that resulted in a 75% carbon reduction compared to standard EBID. Lastly, a sequential deposition plus purification process was also developed and resulted in deposition of pure platinum deposits with high fidelity and shape retention.« less
Single shot laser speckle based 3D acquisition system for medical applications
NASA Astrophysics Data System (ADS)
Khan, Danish; Shirazi, Muhammad Ayaz; Kim, Min Young
2018-06-01
The state of the art techniques used by medical practitioners to extract the three-dimensional (3D) geometry of different body parts requires a series of images/frames such as laser line profiling or structured light scanning. Movement of the patients during scanning process often leads to inaccurate measurements due to sequential image acquisition. Single shot structured techniques are robust to motion but the prevalent challenges in single shot structured light methods are the low density and algorithm complexity. In this research, a single shot 3D measurement system is presented that extracts the 3D point cloud of human skin by projecting a laser speckle pattern using a single pair of images captured by two synchronized cameras. In contrast to conventional laser speckle 3D measurement systems that realize stereo correspondence by digital correlation of projected speckle patterns, the proposed system employs KLT tracking method to locate the corresponding points. The 3D point cloud contains no outliers and sufficient quality of 3D reconstruction is achieved. The 3D shape acquisition of human body parts validates the potential application of the proposed system in the medical industry.
Inert gas enhanced laser-assisted purification of platinum electron-beam-induced deposits
Stanford, Michael G.; Lewis, Brett B.; Noh, Joo Hyon; ...
2015-06-30
Electron-beam-induced deposition patterns, with composition of PtC 5, were purified using a pulsed laser-induced purification reaction to erode the amorphous carbon matrix and form pure platinum deposits. Enhanced mobility of residual H 2O molecules via a localized injection of inert Ar–H 2 (4%) is attributed to be the reactive gas species for purification of the deposits. Surface purification of deposits was realized at laser exposure times as low as 0.1 s. The ex situ purification reaction in the deposit interior was shown to be rate-limited by reactive gas diffusion into the deposit, and deposit contraction associated with the purification processmore » caused some loss of shape retention. To circumvent the intrinsic flaws of the ex situ anneal process, in situ deposition and purification techniques were explored that resemble a direct write atomic layer deposition (ALD) process. First, we explored a laser-assisted electron-beam-induced deposition (LAEBID) process augmented with reactive gas that resulted in a 75% carbon reduction compared to standard EBID. Lastly, a sequential deposition plus purification process was also developed and resulted in deposition of pure platinum deposits with high fidelity and shape retention.« less
[Application of selection criteria in sequential double lung transplantation].
Borro, J M; Tarazona, V; Vicente, R; Cafarena, J M; Ramos, F; Sales, G; Galán, G; Lozano, C; Morant, P; Calvo, V; Morcillo, A; París, F
1999-03-01
Since the first sequential double lung transplant was performed in 1986, such procedures have been increasing in number and the criteria used as indications for this type of surgery have broadened. Our aim was to reflect on the application of selection criteria and to describe the anesthetic and surgical techniques and postoperative follow-up of 72 patients who underwent this type of transplant surgery between March 1993 and December 1998. Actuarial survival five years after surgery was 74.4%. Among patients requiring transplantation after septic disease, actuarial survival was 90.8% for cystic fibrosis and 88.2% for bronchiectasis. Of the preoperative risk factors analyzed (prior surgery, pachypleuritis, multiresistant germs, poor nutrition, mechanical ventilation and corticoid therapy), only prior treatment with high doses of corticoids proved significant. Eleven patients have been diagnosed of bronchiolitis obliterans, four have died and only two continue to experience difficulties in daily living. The high survival rate and the restriction-free life after recovery lead us to consider sequential double lung transplantation to be the treatment of choice for all pulmonary diseases.
Flexible sequential designs for multi-arm clinical trials.
Magirr, D; Stallard, N; Jaki, T
2014-08-30
Adaptive designs that are based on group-sequential approaches have the benefit of being efficient as stopping boundaries can be found that lead to good operating characteristics with test decisions based solely on sufficient statistics. The drawback of these so called 'pre-planned adaptive' designs is that unexpected design changes are not possible without impacting the error rates. 'Flexible adaptive designs' on the other hand can cope with a large number of contingencies at the cost of reduced efficiency. In this work, we focus on two different approaches for multi-arm multi-stage trials, which are based on group-sequential ideas, and discuss how these 'pre-planned adaptive designs' can be modified to allow for flexibility. We then show how the added flexibility can be used for treatment selection and sample size reassessment and evaluate the impact on the error rates in a simulation study. The results show that an impressive overall procedure can be found by combining a well chosen pre-planned design with an application of the conditional error principle to allow flexible treatment selection. Copyright © 2014 John Wiley & Sons, Ltd.
Applications of absorption spectroscopy using quantum cascade lasers.
Zhang, Lizhu; Tian, Guang; Li, Jingsong; Yu, Benli
2014-01-01
Infrared laser absorption spectroscopy (LAS) is a promising modern technique for sensing trace gases with high sensitivity, selectivity, and high time resolution. Mid-infrared quantum cascade lasers, operating in a pulsed or continuous wave mode, have potential as spectroscopic sources because of their narrow linewidths, single mode operation, tunability, high output power, reliability, low power consumption, and compactness. This paper reviews some important developments in modern laser absorption spectroscopy based on the use of quantum cascade laser (QCL) sources. Among the various laser spectroscopic methods, this review is focused on selected absorption spectroscopy applications of QCLs, with particular emphasis on molecular spectroscopy, industrial process control, combustion diagnostics, and medical breath analysis.
Sequential and simultaneous choices: testing the diet selection and sequential choice models.
Freidin, Esteban; Aw, Justine; Kacelnik, Alex
2009-03-01
We investigate simultaneous and sequential choices in starlings, using Charnov's Diet Choice Model (DCM) and Shapiro, Siller and Kacelnik's Sequential Choice Model (SCM) to integrate function and mechanism. During a training phase, starlings encountered one food-related option per trial (A, B or R) in random sequence and with equal probability. A and B delivered food rewards after programmed delays (shorter for A), while R ('rejection') moved directly to the next trial without reward. In this phase we measured latencies to respond. In a later, choice, phase, birds encountered the pairs A-B, A-R and B-R, the first implementing a simultaneous choice and the second and third sequential choices. The DCM predicts when R should be chosen to maximize intake rate, and SCM uses latencies of the training phase to predict choices between any pair of options in the choice phase. The predictions of both models coincided, and both successfully predicted the birds' preferences. The DCM does not deal with partial preferences, while the SCM does, and experimental results were strongly correlated to this model's predictions. We believe that the SCM may expose a very general mechanism of animal choice, and that its wider domain of success reflects the greater ecological significance of sequential over simultaneous choices.
Becker, Thorsten H.
2018-01-01
Current post-process heat treatments applied to selective laser melting produced Ti-6Al-4V do not achieve the same microstructure and therefore superior tensile behaviour of thermomechanical processed wrought Ti-6Al-4V. Due to the growing demand for selective laser melting produced parts in industry, research and development towards improved mechanical properties is ongoing. This study is aimed at developing post-process annealing strategies to improve tensile behaviour of selective laser melting produced Ti-6Al-4V parts. Optical and electron microscopy was used to study α grain morphology as a function of annealing temperature, hold time and cooling rate. Quasi-static uniaxial tensile tests were used to measure tensile behaviour of different annealed parts. It was found that elongated α’/α grains can be fragmented into equiaxial grains through applying a high temperature annealing strategy. It is shown that bi-modal microstructures achieve a superior tensile ductility to current heat treated selective laser melting produced Ti-6Al-4V samples. PMID:29342079
NASA Astrophysics Data System (ADS)
Sapozhnikov, Michael
2018-03-01
A history of the development of selective laser spectroscopy is presented, beginning with a pioneering work by Yu. V. Denisov and V. A. Kizel in 1967, who were the first to demonstrate the possibility of removing the inhomogeneous broadening of luminescence spectra of impurity ions in glasses upon monochromatic resonance excitation. Selective excitation of optical centers can be achieved due to existence of zero-phonon transitions corresponding to narrow homogeneous zero-phonon lines in the spectra of impurity centers in solids, which are hidden in broad inhomogeneous optical bands upon usual nonselective excitation. The fundamentals of zero-phonon transition spectroscopy are considered and the mechanism of removing the inhomogeneous broadening of optical spectra of ions and molecules in crystals and amorphous solids under selective laser excitation of luminescence and persistent hole burning in absorption spectra is presented in detail. Various applications of selective laser spectroscopy for fundamental and applied studies are discussed.
The impact of dispersion on selective laser melting of titanium and niobium fine powders mixture
NASA Astrophysics Data System (ADS)
Razin, A.; Ovchinnikov, V.; Akhmetshin, R.; Krinitcyn, M.; Fedorov, V.; Akhmetshina, V.
2016-11-01
This paper is dedicated to the study of selective laser melting process of metal powders. Experiments were performed in the Research Center Modern Manufacturing Technologies of TPU with the fine powders of titanium and niobium. The research was carried out on 3D laser printer designed at TPU. In the framework of experiments aimed at determining possibilities of obtaining niobium-titanium alloy by SLS (selective laser sintering) there were studied the basic processes of laser melting and their effect on the quality of final samples and products. We determined operation modes of 3D printers which allow obtaining high quality of printed sample surface. The research results show that rigid requirements related to powder dispersiveness and proportions are needed to achieve better quality of products.
Preparing the Teacher of Tomorrow
ERIC Educational Resources Information Center
Hemp, Paul E.
1976-01-01
Suggested ways of planning and conducting high quality teacher preparation programs are discussed under major headings of student selection, sequential courses and experiences, and program design. (HD)
NASA Astrophysics Data System (ADS)
Shaw, Darren; Stone, Kevin; Ho, K. C.; Keller, James M.; Luke, Robert H.; Burns, Brian P.
2016-05-01
Forward looking ground penetrating radar (FLGPR) has the benefit of detecting objects at a significant standoff distance. The FLGPR signal is radiated over a large surface area and the radar signal return is often weak. Improving detection, especially for buried in road targets, while maintaining an acceptable false alarm rate remains to be a challenging task. Various kinds of features have been developed over the years to increase the FLGPR detection performance. This paper focuses on investigating the use of as many features as possible for detecting buried targets and uses the sequential feature selection technique to automatically choose the features that contribute most for improving performance. Experimental results using data collected at a government test site are presented.
Chan, Kenneth H; Fried, Daniel
2012-02-09
Lasers can ablate/remove tissue in a non-contact mode of operation and a pulsed laser beam does not interfere with the ability to image the tooth surface, therefore lasers are ideally suited for integration with imaging devices for image-guided ablation. Laser energy can be rapidly and efficiently delivered to tooth surfaces using a digitally controlled laser beam scanning system for precise and selective laser ablation with minimal loss of healthy tissues. Under the appropriate irradiation conditions such laser energy can induce beneficial chemical and morphological changes in the walls of the drilled cavity that can increase resistance to further dental decay and produce surfaces with enhanced adhesive properties to restorative materials. Previous studies have shown that images acquired using near-IR transillumination, optical coherence tomography and fluorescence can be used to guide the laser for selective removal of demineralized enamel. Recent studies have shown that NIR reflectance measurements at 1470-nm can be used to obtain images of enamel demineralization with very high contrast. The purpose of this study was to demonstrate that image guided ablation of occlusal lesions can be successfully carried out using a NIR reflectance imaging system coupled with a carbon dioxide laser operating at 9.3-μm with high pulse repetition rates.
Diode-laser-based RIMS measurements of strontium-90
NASA Astrophysics Data System (ADS)
Bushaw, B. A.; Cannon, B. D.
1998-12-01
Double- and triple-resonance excitation schemes for the ionization of strontium are presented. Use of single-mode diode lasers for the resonance excitations provides a high degree of optical isotopic selectivity: with double-resonance, selectivity of >104 for 90Sr against the stable Sr isotopes has been demonstrated. Measurement of lineshapes and stable isotope shifts in the triple-resonance process indicate that optical selectivity should increase to ˜109. When combined with mass spectrometer selectivity this is sufficient for measurement of 90Sr at background environmental levels. Additionally, autoionizing resonances have been investigated for improving ionization efficiency with lower power lasers.
Suppressing correlations in massively parallel simulations of lattice models
NASA Astrophysics Data System (ADS)
Kelling, Jeffrey; Ódor, Géza; Gemming, Sibylle
2017-11-01
For lattice Monte Carlo simulations parallelization is crucial to make studies of large systems and long simulation time feasible, while sequential simulations remain the gold-standard for correlation-free dynamics. Here, various domain decomposition schemes are compared, concluding with one which delivers virtually correlation-free simulations on GPUs. Extensive simulations of the octahedron model for 2 + 1 dimensional Kardar-Parisi-Zhang surface growth, which is very sensitive to correlation in the site-selection dynamics, were performed to show self-consistency of the parallel runs and agreement with the sequential algorithm. We present a GPU implementation providing a speedup of about 30 × over a parallel CPU implementation on a single socket and at least 180 × with respect to the sequential reference.
Flowe, Heather D; Ebbesen, Ebbe B
2007-02-01
Two experiments investigated whether remembering is affected by the similarity of the study face relative to the alternatives in a lineup. In simultaneous and sequential lineups, choice rates and false alarms were larger in low compared to high similarity lineups, indicating criterion placement was affected by lineup similarity structure (Experiment 1). In Experiment 2, foil choices and similarity ranking data for target present lineups were compared to responses made when the target was removed from the lineup (only the 5 foils were presented). The results indicated that although foils were selected more often in target-removed lineups in the simultaneous compared to the sequential condition, responses shifted from the target to one of the foils at equal rates across lineup procedures.
A new phase transformation path from nanodiamond to new-diamond via an intermediate carbon onion
NASA Astrophysics Data System (ADS)
Xiao, J.; Li, J. L.; Liu, P.; Yang, G. W.
2014-11-01
The investigation of carbon allotropes such as graphite, diamond, fullerenes, nanotubes and carbon onions and mechanisms that underlie their mutual phase transformation is a long-standing problem of great fundamental importance. New diamond (n-diamond) is a novel metastable phase of carbon with a face-centered cubic structure; it is called ``new diamond'' because many reflections in its electron diffraction pattern are similar to those of diamond. However, producing n-diamond from raw carbon materials has so far been challenging due to n-diamond's higher formation energy than that of diamond. Here, we, for the first time, demonstrate a new phase transformation path from nanodiamond to n-diamond via an intermediate carbon onion in the unique process of laser ablation in water, and establish that water plays a crucial role in the formation of n-diamond. When a laser irradiates colloidal suspensions of nanodiamonds at ambient pressure and room temperature, nanodiamonds are first transformed into carbon onions serving as an intermediate phase, and sequentially carbon onions are transformed into n-diamonds driven by the laser-induced high temperature and high pressure from the carbon onion as a nanoscaled temperature and pressure cell upon the process of laser irradiation in a liquid. This phase transformation not only provides new insight into the physical mechanism involved, but also offers one suitable opportunity for breaking controllable pathways between n-diamond and carbon allotropes such as diamond and carbon onions.The investigation of carbon allotropes such as graphite, diamond, fullerenes, nanotubes and carbon onions and mechanisms that underlie their mutual phase transformation is a long-standing problem of great fundamental importance. New diamond (n-diamond) is a novel metastable phase of carbon with a face-centered cubic structure; it is called ``new diamond'' because many reflections in its electron diffraction pattern are similar to those of diamond. However, producing n-diamond from raw carbon materials has so far been challenging due to n-diamond's higher formation energy than that of diamond. Here, we, for the first time, demonstrate a new phase transformation path from nanodiamond to n-diamond via an intermediate carbon onion in the unique process of laser ablation in water, and establish that water plays a crucial role in the formation of n-diamond. When a laser irradiates colloidal suspensions of nanodiamonds at ambient pressure and room temperature, nanodiamonds are first transformed into carbon onions serving as an intermediate phase, and sequentially carbon onions are transformed into n-diamonds driven by the laser-induced high temperature and high pressure from the carbon onion as a nanoscaled temperature and pressure cell upon the process of laser irradiation in a liquid. This phase transformation not only provides new insight into the physical mechanism involved, but also offers one suitable opportunity for breaking controllable pathways between n-diamond and carbon allotropes such as diamond and carbon onions. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr05246c
Item Selection Criteria with Practical Constraints for Computerized Classification Testing
ERIC Educational Resources Information Center
Lin, Chuan-Ju
2011-01-01
This study compares four item selection criteria for a two-category computerized classification testing: (1) Fisher information (FI), (2) Kullback-Leibler information (KLI), (3) weighted log-odds ratio (WLOR), and (4) mutual information (MI), with respect to the efficiency and accuracy of classification decision using the sequential probability…
ERIC Educational Resources Information Center
Wang, Chun; Chang, Hua-Hua
2011-01-01
Over the past thirty years, obtaining diagnostic information from examinees' item responses has become an increasingly important feature of educational and psychological testing. The objective can be achieved by sequentially selecting multidimensional items to fit the class of latent traits being assessed, and therefore Multidimensional…
Mutual Information Item Selection in Adaptive Classification Testing
ERIC Educational Resources Information Center
Weissman, Alexander
2007-01-01
A general approach for item selection in adaptive multiple-category classification tests is provided. The approach uses mutual information (MI), a special case of the Kullback-Leibler distance, or relative entropy. MI works efficiently with the sequential probability ratio test and alleviates the difficulties encountered with using other local-…
NASA Astrophysics Data System (ADS)
Saiki, Masayuki; Ishii, Katsunori; Yoshikawa, Kazushi; Yasuo, Kenzo; Yamamoto, Kazuyo; Awazu, Kunio
2011-03-01
Optical technologies have good potential for caries detection, prevention, excavation, and the realization of minimal intervention dentistry. This study aimed to develop a selective excavation technique of carious tissue using the specific absorption in 6 μm wavelength range. Bovine dentin demineralized with lactic acid solution was used as a carious dentin model. A mid-infrared tunable pulsed laser was obtained by difference-frequency generation technique. The wavelength was tuned to 6.02 and 6.42 μm which correspond to absorption bands called amide I and amide II, respectively. The laser delivers 5 ns pulse width at a repetition rate of 10 Hz. The morphological change after irradiation was observed with a scanning electron microscope, and the measurement of ablation depth was performed with a confocal laser microscope. At λ = 6.02 μm and the average power density of 15 W/cm2, demineralized dentin was removed selectively with less-invasive effect on sound dentin. The wavelength of 6.42 μm also showed the possibility of selective removal. High ablation efficiency and low thermal side effect were observed using the nanosecond pulsed laser with λ = 6.02 μm. In the near future, development of compact laser device will open the minimal invasive laser treatment to the dental clinic.
Ahern, Adam T.; Subramanian, Ramachandran; Saliba, Georges; ...
2016-12-22
Biomass burning is a large source of light-absorbing refractory black carbon (rBC) particles with a wide range of morphologies and sizes. The net radiative forcing from these particles is strongly dependent on the amount and composition of non-light-absorbing material internally mixed with the rBC and on the morphology of the mixed particles. Understanding how the mixing state and morphology of biomass-burning aerosol evolves in the atmosphere is critical for constraining the influence of these particles on radiative forcing and climate. We investigated the response of two commercial laser-based particle mass spectrometers, the vacuum ultraviolet (VUV) ablation LAAPTOF and the IRmore » vaporization SP-AMS, to monodisperse biomass-burning particles as we sequentially coated the particles with secondary organic aerosol (SOA) from α-pinene ozonolysis. We studied three mobility-selected soot core sizes, each with a number of successively thicker coatings of SOA applied. Using IR laser vaporization, the SP-AMS had different changes in sensitivity to rBC compared to potassium as a function of applied SOA coatings. We show that this is due to different effective beam widths for the IR laser vaporization region of potassium versus black carbon. The SP-AMS's sensitivity to black carbon (BC) mass was not observed to plateau following successive SOA coatings, despite achieving high OA : BC mass ratios greater than 9. We also measured the ion fragmentation pattern of biomass-burning rBC and found it changed only slightly with increasing SOA mass. The average organic matter ion signal measured by the LAAPTOF demonstrated a positive correlation with the condensed SOA mass on individual particles, despite the inhomogeneity of the particle core compositions. This demonstrates that the LAAPTOF can obtain quantitative mass measurements of aged soot-particle composition from realistic biomass-burning particles with complex morphologies and composition.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahern, Adam T.; Subramanian, Ramachandran; Saliba, Georges
Biomass burning is a large source of light-absorbing refractory black carbon (rBC) particles with a wide range of morphologies and sizes. The net radiative forcing from these particles is strongly dependent on the amount and composition of non-light-absorbing material internally mixed with the rBC and on the morphology of the mixed particles. Understanding how the mixing state and morphology of biomass-burning aerosol evolves in the atmosphere is critical for constraining the influence of these particles on radiative forcing and climate. We investigated the response of two commercial laser-based particle mass spectrometers, the vacuum ultraviolet (VUV) ablation LAAPTOF and the IRmore » vaporization SP-AMS, to monodisperse biomass-burning particles as we sequentially coated the particles with secondary organic aerosol (SOA) from α-pinene ozonolysis. We studied three mobility-selected soot core sizes, each with a number of successively thicker coatings of SOA applied. Using IR laser vaporization, the SP-AMS had different changes in sensitivity to rBC compared to potassium as a function of applied SOA coatings. We show that this is due to different effective beam widths for the IR laser vaporization region of potassium versus black carbon. The SP-AMS's sensitivity to black carbon (BC) mass was not observed to plateau following successive SOA coatings, despite achieving high OA : BC mass ratios greater than 9. We also measured the ion fragmentation pattern of biomass-burning rBC and found it changed only slightly with increasing SOA mass. The average organic matter ion signal measured by the LAAPTOF demonstrated a positive correlation with the condensed SOA mass on individual particles, despite the inhomogeneity of the particle core compositions. This demonstrates that the LAAPTOF can obtain quantitative mass measurements of aged soot-particle composition from realistic biomass-burning particles with complex morphologies and composition.« less
Single mode pulsed dye laser oscillator
Hackel, Richard P.
1992-01-01
A single mode pulsed dye laser oscillator is disclosed. The dye laser oscillator provides for improved power efficiency by reducing the physical dimensions of the overall laser cavity, which improves frequency selection capability.
Lead extraction by selective operation of a nanosecond-pulsed 355nm laser
NASA Astrophysics Data System (ADS)
Herzog, Amir; Bogdan, Stefan; Glikson, Michael; Ishaaya, Amiel A.; Love, Charles
2016-03-01
Lead extraction (LE) is necessary for patients who are suffering from a related infection, or in opening venous occlusions that prevent the insertion of additional lead. In severe cases of fibrous encapsulation of the lead within a vein, laser-based cardiac LE has become one of the foremost methods of removal. In cases where the laser radiation (typically at 308 nm wavelength) interacts with the vein wall rather than with the fibrotic lesion, severe injury and subsequent bleeding may occur. Selective tissue ablation was previously demonstrated by a laser operating in the UV regime; however, it requires the use of sensitizers (e.g.: tetracycline). In this study, we present a preliminary examination of efficacy and safety aspects in the use of a nanosecond-pulsed solid-state laser radiation, at 355 nm wavelength, guided in a catheter consisting of optical fibers, in LE. Specifically, we demonstrate a correlation between the tissue elasticity and the catheter advancement rate, in ex-vivo experiments. Our results indicate a selectivity property for specific parameters of the laser radiation and catheter design. The selectivity is attributed to differences in the mechanical properties of the fibrotic tissue and a normal vein wall, leading to a different photomechanical response of the tissue's extracellular matrix. Furthermore, we performed successful in-vivo animal trials, providing a basic proof of concept for using the suggested scheme in LE. Selective operation using a 355 nm laser may reduce the risk of blood vessel perforation as well as the incidence of major adverse events.
Hall, David B; Meier, Ulrich; Diener, Hans-Cristoph
2005-06-01
The trial objective was to test whether a new mechanism of action would effectively treat migraine headaches and to select a dose range for further investigation. The motivation for a group sequential, adaptive, placebo-controlled trial design was (1) limited information about where across the range of seven doses to focus attention, (2) a need to limit sample size for a complicated inpatient treatment and (3) a desire to reduce exposure of patients to ineffective treatment. A design based on group sequential and up and down designs was developed and operational characteristics were explored by trial simulation. The primary outcome was headache response at 2 h after treatment. Groups of four treated and two placebo patients were assigned to one dose. Adaptive dose selection was based on response rates of 60% seen with other migraine treatments. If more than 60% of treated patients responded, then the next dose was the next lower dose; otherwise, the dose was increased. A stopping rule of at least five groups at the target dose and at least four groups at that dose with more than 60% response was developed to ensure that a selected dose would be statistically significantly (p=0.05) superior to placebo. Simulations indicated good characteristics in terms of control of type 1 error, sufficient power, modest expected sample size and modest bias in estimation. The trial design is attractive for phase 2 clinical trials when response is acute and simple, ideally binary, placebo comparator is required, and patient accrual is relatively slow allowing for the collection and processing of results as a basis for the adaptive assignment of patients to dose groups. The acute migraine trial based on this design was successful in both proof of concept and dose range selection.
Tella-Amo, Marcel; Peter, Loic; Shakir, Dzhoshkun I.; Deprest, Jan; Iglesias, Juan Eugenio; Ourselin, Sebastien
2018-01-01
Abstract. The most effective treatment for twin-to-twin transfusion syndrome is laser photocoagulation of the shared vascular anastomoses in the placenta. Vascular connections are extremely challenging to locate due to their caliber and the reduced field-of-view of the fetoscope. Therefore, mosaicking techniques are beneficial to expand the scene, facilitate navigation, and allow vessel photocoagulation decision-making. Local vision-based mosaicking algorithms inherently drift over time due to the use of pairwise transformations. We propose the use of an electromagnetic tracker (EMT) sensor mounted at the tip of the fetoscope to obtain camera pose measurements, which we incorporate into a probabilistic framework with frame-to-frame visual information to achieve globally consistent sequential mosaics. We parametrize the problem in terms of plane and camera poses constrained by EMT measurements to enforce global consistency while leveraging pairwise image relationships in a sequential fashion through the use of local bundle adjustment. We show that our approach is drift-free and performs similarly to state-of-the-art global alignment techniques like bundle adjustment albeit with much less computational burden. Additionally, we propose a version of bundle adjustment that uses EMT information. We demonstrate the robustness to EMT noise and loss of visual information and evaluate mosaics for synthetic, phantom-based and ex vivo datasets. PMID:29487889
Souady, Jamal; Soltwisch, Jens; Dreisewerd, Klaus; Haier, Jörg; Peter-Katalinić, Jasna; Müthing, Johannes
2009-11-15
The thin-layer chromatography (TLC) immunoenzyme overlay assay is a widely used tool for antibody-mediated identification of glycosphingolipids (GSLs) in mixtures. However, because the majority of GSLs is left unexamined in a chromatogram of a single assay, we developed a novel method that permits detection of various GSLs by sequential multiple immunostaining combined with individual coloring of GSLs in the same chromatogram. Specific staining was achieved by means of primary anti-GSL antibodies, directed against lactosylceramide, globotriaosylceramide, and globotetraosylceramide, in conjunction with alkaline phosphatase (AP)- or horseradish peroxidase (HRP)-conjugated secondary antibodies together with the appropriate chromogenic substrates. Triple coloring with 5-bromo-4-chloro-3-indolyl phosphate (BCIP)-AP, Fast Red-AP, and 3,3'-diaminobenzidine (DAB)-HRP resulted in blue, red, and black precipitates, respectively, following three sequential immunostaining rounds. Structures of antibody-detected GSLs were determined by direct coupling of TLC with infrared matrix-assisted laser desorption/ionization orthogonal time-of-flight mass spectrometry. This combinatorial technique was used to demonstrate structural GSL profiling of crude lipid extracts from human hepatocellular cancer. This powerful technology allows efficient structural characterization of GSLs in small tissue samples and marks a further step forward in the emerging field of glycosphingolipidomics.
NASA Astrophysics Data System (ADS)
Sumida, David Shuji
PO(X('2)(PI)) is produced via the collision-free infrared multiple photon dissociation (IRMPD) of volatile organophosphorus molecules, and is detected by 2-frequency 2-photon ionization, using the B('2)(SIGMA)('+) state to provide a spectral signature from which X('2)(PI) populations are obtained. Sequential dissociations occur during the IR laser photolysis, in which nascent fragments continue to undergo IRMPD, and PO(X('2)(PI)) accrues from a series of bond fission reactions. Nascent vibrational, rotational, and translational excitations are in sensible accord with this mechanism, except for a few rotational states near J = 19.5. Unlike the nuclear degrees of freedom, the PO(X('2)(PI)) spin-orbit states are populated quite selectively. The ('2)(PI)(,3/2) state, lying only 224 cm('-1) above the ('2)(PI)(,1/2) ground state, contains only (TURN)11% of the population, compared to 34% for a 300K sample. This result is unambiguous; it persists with all precursors, laser fluences, etc., and is verified by comparisons to spectra obtained using a microwave discharge, a flame, and when thermalizing nascent excitations with an inert diluent. This result underscores the sanctity of the separate potential surfaces which correlate to the product spin -orbit states, and the small amount of ('2)(PI)(,3/2) population can be accounted for by non-adiabatic coupling during dissociation, and/or 'freezing' the amount of S(,1) character in an excited precursor in which S(,0) and S(,1) are coupled non-radiatively. We note that such electronic specificity should be dealt with in the analogous recombination reactions. (Copies available exclusively from Micrographics Department, Doheny Library, USC, Los Angeles, CA 90089.).
Lee, Tae Hoon; Hwang, Soon Oh; Choi, Hyun Jong; Jung, Yunho; Cha, Sang Woo; Chung, Il-Kwun; Moon, Jong Ho; Cho, Young Deok; Park, Sang-Heum; Kim, Sun-Joo
2014-02-17
Numerous clinical trials to improve the success rate of biliary access in difficult biliary cannulation (DBC) during ERCP have been reported. However, standard guidelines or sequential protocol analysis according to different methods are limited in place. We planned to investigate a sequential protocol to facilitate selective biliary access for DBC during ERCP. This prospective clinical study enrolled 711 patients with naïve papillae at a tertiary referral center. If wire-guided cannulation was deemed to have failed due to the DBC criteria, then according to the cannulation algorithm early precut fistulotomy (EPF; cannulation time > 5 min, papillary contacts > 5 times, or hook-nose-shaped papilla), double-guidewire cannulation (DGC; unintentional pancreatic duct cannulation ≥ 3 times), and precut after placement of a pancreatic stent (PPS; if DGC was difficult or failed) were performed sequentially. The main outcome measurements were the technical success, procedure outcomes, and complications. Initially, a total of 140 (19.7%) patients with DBC underwent EPF (n = 71) and DGC (n = 69). Then, in DGC group 36 patients switched to PPS due to difficulty criteria. The successful biliary cannulation rate was 97.1% (136/140; 94.4% [67/71] with EPF, 47.8% [33/69] with DGC, and 100% [36/36] with PPS; P < 0.001). The mean successful cannulation time (standard deviation) was 559.4 (412.8) seconds in EPF, 314.8 (65.2) seconds in DGC, and 706.0 (469.4) seconds in PPS (P < 0.05). The DGC group had a relatively low successful cannulation rate (47.8%) but had a shorter cannulation time compared to the other groups due to early switching to the PPS method in difficult or failed DGC. Post-ERCP pancreatitis developed in 14 (10%) patients (9 mild, 1 moderate), which did not differ significantly among the groups (P = 0.870) or compared with the conventional group (P = 0.125). Based on the sequential protocol analysis, EPF, DGC, and PPS may be safe and feasible for DBC. The use of EPF in selected DBC criteria, DGC in unintentional pancreatic duct cannulations, and PPS in failed or difficult DGC may facilitate successful biliary cannulation.
Selective Removal of Natural Occlusal Caries by Coupling Near-infrared Imaging with a CO2 Laser
Tao, You-Chen; Fried, Daniel
2011-01-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. Last year we successfully demonstrated that near-IR images can be used to guide a CO2 laser ablation system for the selective removal of artificial caries lesions on smooth surfaces. The objective of this study was to test the hypothesis that two-dimensional near-infrared images of natural occlusal caries can be used to guide a CO2 laser for selective removal. Two-dimensional NIR images were acquired at 1310-nm of extracted human molar teeth with occlusal caries. Polarization sensitive optical coherence tomography (PS-OCT) was also used to acquire depth-resolved images of the lesion areas. An imaging processing module was developed to analyze the NIR imaging output and generate optical maps that were used to guide a CO2 laser to selectively remove the lesions at a uniform depth. Post-ablation NIR images were acquired to verify caries removal. Based on the analysis of the NIR images, caries lesions were selectively removed with a CO2 laser while sound tissues were conserved. However, the removal rate varied markedly with the severity of decay and multiple passes were required for caries removal. These initial results are promising but indicate that the selective removal of natural caries is more challenging than the selective removal of artificial lesions due to varying tooth geometry, the highly variable organic/mineral ratio in natural lesions and more complicated lesion structure. PMID:21909225
Selective removal of natural occlusal caries by coupling near-infrared imaging with a CO II laser
NASA Astrophysics Data System (ADS)
Tao, You-Chen; Fried, Daniel
2008-02-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. Last year we successfully demonstrated that near-IR images can be used to guide a CO2 laser ablation system for the selective removal of artificial caries lesions on smooth surfaces. The objective of this study was to test the hypothesis that two-dimensional near-infrared images of natural occlusal caries can be used to guide a CO2 laser for selective removal. Two-dimensional NIR images were acquired at 1310-nm of extracted human molar teeth with occlusal caries. Polarization sensitive optical coherence tomography (PS-OCT) was also used to acquire depth-resolved images of the lesion areas. An imaging processing module was developed to analyze the NIR imaging output and generate optical maps that were used to guide a CO2 laser to selectively remove the lesions at a uniform depth. Post-ablation NIR images were acquired to verify caries removal. Based on the analysis of the NIR images, caries lesions were selectively removed with a CO2 laser while sound tissues were conserved. However, the removal rate varied markedly with the severity of decay and multiple passes were required for caries removal. These initial results are promising but indicate that the selective removal of natural caries is more challenging than the selective removal of artificial lesions due to varying tooth geometry, the highly variable organic/mineral ratio in natural lesions and more complicated lesion structure.
Selective Removal of Natural Occlusal Caries by Coupling Near-infrared Imaging with a CO(2) Laser.
Tao, You-Chen; Fried, Daniel
2008-03-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. Last year we successfully demonstrated that near-IR images can be used to guide a CO(2) laser ablation system for the selective removal of artificial caries lesions on smooth surfaces. The objective of this study was to test the hypothesis that two-dimensional near-infrared images of natural occlusal caries can be used to guide a CO(2) laser for selective removal. Two-dimensional NIR images were acquired at 1310-nm of extracted human molar teeth with occlusal caries. Polarization sensitive optical coherence tomography (PS-OCT) was also used to acquire depth-resolved images of the lesion areas. An imaging processing module was developed to analyze the NIR imaging output and generate optical maps that were used to guide a CO(2) laser to selectively remove the lesions at a uniform depth. Post-ablation NIR images were acquired to verify caries removal. Based on the analysis of the NIR images, caries lesions were selectively removed with a CO(2) laser while sound tissues were conserved. However, the removal rate varied markedly with the severity of decay and multiple passes were required for caries removal. These initial results are promising but indicate that the selective removal of natural caries is more challenging than the selective removal of artificial lesions due to varying tooth geometry, the highly variable organic/mineral ratio in natural lesions and more complicated lesion structure.
Single mode pulsed dye laser oscillator
Hackel, R.P.
1992-11-24
A single mode pulsed dye laser oscillator is disclosed. The dye laser oscillator provides for improved power efficiency by reducing the physical dimensions of the overall laser cavity, which improves frequency selection capability. 6 figs.
NASA Astrophysics Data System (ADS)
Wendt, Klaus; Gottwald, Tina; Hanstorp, Dag; Mattolat, Christoph; Raeder, Sebastian; Rothe, Sebastian; Schwellnus, Fabio; Havener, Charles; Lassen, Jens; Liu, Yuan
2010-02-01
Laser ion sources based on resonant excitation and ionization of atoms are well-established tools for selective and efficient production of radioactive ion beams. A recent trend is the complementary installation of reliable state-of-the-art all solid-state Ti:Sapphire laser systems. To date, 35 elements of the Periodic Table are available at laser ion sources by using these novel laser systems, which complements the overall accessibility to 54 elements including use of traditional dye lasers. Recent progress in the field concerns the identification of suitable optical excitation schemes for Ti:Sapphire laser excitation as well as technical developments of the source in respect to geometry, cavity material as well as by incorporation of an ion guide system in the form of the laser ion source trap LIST.
Optical field ionization of atoms and ions using ultrashort laser pulses
NASA Astrophysics Data System (ADS)
Fittinghoff, D. N.
1993-12-01
This dissertation research is an investigation of the strong optical field ionization of atoms and ions by 120-fs, 614-run laser pulses and 130-fs, 800-nm laser pulses. The experiments have shown ionization that is enhanced above the predictions of sequential tunneling models for He(+2), Ne(+2), and Ar(+2). The ion yields for He(+1), Ne(sup +1) and Ar(sup +1) agree well with the theoretical predictions of optical tunneling models. Investigation of the polarization dependence of the ionization indicates that the enhancements are consistent with a nonsequential ionization mechanism in which the linearly polarized field drives the electron wavefunction back toward the ion core and causes double ionization through inelastic e-2e scattering. These investigations have initiated a number of other studies by other groups and are of current scientific interest in the fields of high-irradiance laser-matter interactions and production of high-density plasmas. This work involved the following: (1) Understanding the characteristic nature of the ion yields produced by tunneling ionization through investigation of analytic solutions for tunneling at optical frequencies. (2) Extensive characterization of the pulses produced by 614-nm and 800-ran ultrashort pulse lasers. Absolute calibration of the irradiance scale produced shows the practicality of the inverse problem--measuring peak laser irradiance using ion yields. (3) Measuring the ion yields for three noble gases using linear, circular and elliptical polarizations of laser pulses at 614-nm and 800-nm. The measurements are some of the first measurements for pulse widths as low as 120-fs.
Molecular effects of fractional carbon dioxide laser resurfacing on photodamaged human skin.
Reilly, Michael J; Cohen, Marc; Hokugo, Akishige; Keller, Gregory S
2010-01-01
Objective To elucidate the sequential changes in protein expression that play a role in the clinically beneficial results seen with fractional carbon dioxide (CO(2)) laser resurfacing of the face and neck. Methods Nine healthy volunteers were recruited for participation from the senior author's facial plastic surgery practice. After informed consent was obtained, each volunteer underwent a 2-mm punch biopsy from a discrete area of infra-auricular neck skin prior to laser treatment. Patients then immediately underwent laser resurfacing of photodamaged face and neck skin at a minimal dose (30 W for 0.1 second) with the Pixel Perfect fractional CO(2) laser. On completion of the treatment, another biopsy specimen was taken adjacent to the first site. Additional biopsy specimens were subsequently taken from adjacent skin at 2 of 3 time points (day 7, day 14, or day 21). RNA was extracted from the specimens, and reverse transcriptase-polymerase chain reaction and protein microarray analysis were performed. Comparisons were then made between time points using pairwise comparison testing. Results We found statistically significant changes in the gene expression of several matrix metalloproteinases (MMPs). The data demonstrate a consistent up-regulation of MMPs 1, 3, 9, and 13, all of which have been previously reported for fully ablative CO(2) laser resurfacing. There was also a statistically significant increase in MMP-10 and MMP-11 levels in this data set. Conclusion This study suggests that the molecular mechanisms of action are similar for both fractional and fully ablative CO(2) laser resurfacing.
Ambient methods and apparatus for rapid laser trace constituent analysis
Snyder, Stuart C.; Partin, Judy K.; Grandy, Jon D.; Jeffery, Charles L.
2002-01-01
A method and apparatus are disclosed for measuring trace amounts of constituents in samples by using laser induced breakdown spectroscopy and laser induced fluorescence under ambient conditions. The laser induced fluorescence is performed at a selected wavelength corresponding to an absorption state of a selected trace constituent. The intensity value of the emission decay signal which is generated by the trace constituent is compared to calibrated emission intensity decay values to determine the amount of trace constituent present.
Lateral electrochemical etching of III-nitride materials for microfabrication
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Jung
Conductivity-selective lateral etching of III-nitride materials is described. Methods and structures for making vertical cavity surface emitting lasers with distributed Bragg reflectors via electrochemical etching are described. Layer-selective, lateral electrochemical etching of multi-layer stacks is employed to form semiconductor/air DBR structures adjacent active multiple quantum well regions of the lasers. The electrochemical etching techniques are suitable for high-volume production of lasers and other III-nitride devices, such as lasers, HEMT transistors, power transistors, MEMs structures, and LEDs.
Prentice, Boone M; Chumbley, Chad W; Hachey, Brian C; Norris, Jeremy L; Caprioli, Richard M
2016-10-04
Quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) approaches have historically suffered from poor accuracy and precision mainly due to the nonuniform distribution of matrix and analyte across the target surface, matrix interferences, and ionization suppression. Tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity as well as improve signal-to-noise ratios by eliminating interferences from chemical noise, alleviating some concerns about dynamic range. However, conventional MALDI TOF/TOF modalities typically only scan for a single MS/MS event per laser shot, and multiplex assays require sequential analyses. We describe here new methodology that allows for multiple TOF/TOF fragmentation events to be performed in a single laser shot. This technology allows the reference of analyte intensity to that of the internal standard in each laser shot, even when the analyte and internal standard are quite disparate in m/z, thereby improving quantification while maintaining chemical specificity and duty cycle. In the quantitative analysis of the drug enalapril in pooled human plasma with ramipril as an internal standard, a greater than 4-fold improvement in relative standard deviation (<10%) was observed as well as improved coefficients of determination (R 2 ) and accuracy (>85% quality controls). Using this approach we have also performed simultaneous quantitative analysis of three drugs (promethazine, enalapril, and verapamil) using deuterated analogues of these drugs as internal standards.
Development of Processing Parameters for Organic Binders Using Selective Laser Sintering
NASA Technical Reports Server (NTRS)
Mobasher, Amir A.
2003-01-01
This document describes rapid prototyping, its relation to Computer Aided Design (CAD), and the application of these techniques to choosing parameters for Selective Laser Sintering (SLS). The document reviews the parameters selected by its author for his project, the SLS machine used, and its software.
Ray tracing method for simulation of laser beam interaction with random packings of powders
NASA Astrophysics Data System (ADS)
Kovalev, O. B.; Kovaleva, I. O.; Belyaev, V. V.
2018-03-01
Selective laser sintering is a technology of rapid manufacturing of a free form that is created as a solid object by selectively fusing successive layers of powder using a laser. The motivation of this study is due to the currently insufficient understanding of the processes and phenomena of selective laser melting of powders whose time scales differ by orders of magnitude. To construct random packings from mono- and polydispersed solid spheres, the algorithm of their generation based on the discrete element method is used. A numerical method of ray tracing is proposed that is used to simulate the interaction of laser radiation with a random bulk packing of spherical particles and to predict the optical properties of the granular layer, the extinction and absorption coefficients, depending on the optical properties of a powder material.
Holmium laser use in the treatment of selected dry eye syndrome complications
NASA Astrophysics Data System (ADS)
Kecik, Dariusz; Kecik, Tadeusz; Kasprzak, Jan; Kecik, Mariusz
1996-03-01
The authors present initial results of treatment selected complications of dry eye syndrome with holmium laser. The lacrimal puncta obliteration and coagulation of the corneal ulcer surface were done.
Schmitt, L; Huth, S; Amann, P M; Marquardt, Y; Heise, R; Fietkau, K; Huth, L; Steiner, T; Hölzle, F; Baron, J M
2018-05-01
Molecular effects of various ablative and non-ablative laser treatments on human skin cells-especially primary effects on epidermal keratinocytes and dermal fibroblasts-are not yet fully understood. We present the first study addressing molecular effects of fractional non-sequential ultrapulsed CO 2 laser treatment using a 3D skin model that allows standardized investigations of time-dependent molecular changes ex vivo. While histological examination was performed to assess morphological changes, we utilized gene expression profiling using microarray and qRT-PCR analyses to identify molecular effects of laser treatment. Irradiated models exhibited dose-dependent morphological changes resulting in an almost complete recovery of the epidermis 5 days after irradiation. On day 5 after laser injury with a laser fluence of 100 mJ/cm 2 , gene array analysis identified an upregulation of genes associated with tissue remodeling and wound healing (e.g., COL12A1 and FGF7), genes that are involved in the immune response (e.g., CXCL12 and CCL8) as well as members of the heat shock protein family (e.g., HSPB3). On the other hand, we detected a downregulation of matrix metalloproteinases (e.g., MMP3), differentiation markers (e.g., LOR and S100A7), and the pro-inflammatory cytokine IL1α.Overall, our findings substantiate the understanding of time-dependent molecular changes after CO 2 laser treatment. The utilized 3D skin model system proved to be a reliable, accurate, and reproducible tool to explore the effects of various laser settings both on skin morphology and gene expression during wound healing.
Haglund, Jr., Richard F.; Ermer, David R.; Baltz-Knorr, Michelle Lee
2004-11-30
A system and method for desorption and ionization of analytes in an ablation medium. In one embodiment, the method includes the steps of preparing a sample having analytes in a medium including at least one component, freezing the sample at a sufficiently low temperature so that at least part of the sample has a phase transition, and irradiating the frozen sample with short-pulse radiation to cause medium ablation and desorption and ionization of the analytes. The method further includes the steps of selecting a resonant vibrational mode of at least one component of the medium and selecting an energy source tuned to emit radiation substantially at the wavelength of the selected resonant vibrational mode. The medium is an electrophoresis medium having polyacrylamide. In one embodiment, the energy source is a laser, where the laser can be a free electron laser tunable to generate short-pulse radiation. Alternatively, the laser can be a solid state laser tunable to generate short-pulse radiation. The laser can emit light at various ranges of wavelength.
Interfacial exciplex formation in bilayers of conjugated polymers
NASA Astrophysics Data System (ADS)
Nobuyasu, R. S.; Araujo, K. A. S.; Cury, L. A.; Jarrosson, T.; Serein-Spirau, F.; Lère-Porte, J.-P.; Dias, F. B.; Monkman, A. P.
2013-10-01
The donor-acceptor interactions in sequential bilayer and blend films are investigated. Steady-state and time-resolved photoluminescence (PL) were measured to characterize the samples at different geometries of photoluminescence collection. At standard excitation, with the laser incidence at 45° of the normal direction of the sample surface, a band related to the aggregate states of donor molecules appears for both blend and bilayer at around 540 nm. For the PL spectra acquired from the edge of the bilayer, with the laser incidence made at normal direction of the sample surface (90° geometry), a new featureless band emission, red-shifted from donor and acceptor emission regions was observed and assigned as the emission from interfacial exciplex states. The conformational complexity coming from donor/acceptor interactions at the heterojunction interface of the bilayer is at the origin of this interfacial exciplex emission.
Scalable Creation of Long-Lived Multipartite Entanglement.
Kaufmann, H; Ruster, T; Schmiegelow, C T; Luda, M A; Kaushal, V; Schulz, J; von Lindenfels, D; Schmidt-Kaler, F; Poschinger, U G
2017-10-13
We demonstrate the deterministic generation of multipartite entanglement based on scalable methods. Four qubits are encoded in ^{40}Ca^{+}, stored in a microstructured segmented Paul trap. These qubits are sequentially entangled by laser-driven pairwise gate operations. Between these, the qubit register is dynamically reconfigured via ion shuttling operations, where ion crystals are separated and merged, and ions are moved in and out of a fixed laser interaction zone. A sequence consisting of three pairwise entangling gates yields a four-ion Greenberger-Horne-Zeilinger state |ψ⟩=(1/sqrt[2])(|0000⟩+|1111⟩), and full quantum state tomography reveals a state fidelity of 94.4(3)%. We analyze the decoherence of this state and employ dynamic decoupling on the spatially distributed constituents to maintain 69(5)% coherence at a storage time of 1.1 sec.
Laser weld jig. [Patent application
Van Blarigan, P.; Haupt, D.L.
1980-12-05
A system is provided for welding a workpiece along a predetermined weld line that may be of irregular shape, which includes the step of forming a lip on the workpiece to extend parallel to the weld line, and moving the workpiece by engaging the lip between a pair of rotatable members. Rotation of one of the members at a constant speed, causes the workpiece to move so that all points on the weld line sequentially pass a fixed point in space at a constant speed, so that a laser welding beam can be directed at that fixed point to form a weld along the weld line. The workpiece can include a reusable jig forming the lip, and with the jig constructed to detachably hold parts to be welded at a position wherein the weld line of the parts extends parallel to the lip on the jig.
Studying Pulsed Laser Deposition conditions for Ni/C-based multi-layers
NASA Astrophysics Data System (ADS)
Bollmann, Tjeerd R. J.
2018-04-01
Nickel carbon based multi-layers are a viable route towards future hard X-ray and soft γ-ray focusing telescopes. Here, we study the Pulsed Laser Deposition growth conditions of such bilayers by Reflective High Energy Electron Diffraction, X-ray Reflectivity and Diffraction, Atomic Force Microscopy, X-ray Photoelectron Spectroscopy and cross-sectional Transmission Electron Microscopy analysis, with emphasis on optimization of process pressure and substrate temperature during growth. The thin multi-layers are grown on a treated SiO substrate resulting in Ni and C layers with surface roughnesses (RMS) of ≤0.2 nm. Small droplets resulting during melting of the targets surface increase the roughness, however, and cannot be avoided. The sequential process at temperatures beyond 300 °C results into intermixing between the two layers, being destructive for the reflectivity of the multi-layer.
Laser-induced selective metallization of polypropylene doped with multiwall carbon nanotubes
NASA Astrophysics Data System (ADS)
Ratautas, Karolis; Gedvilas, Mindaugas; Stankevičiene, Ina; Jagminienė, Aldona; Norkus, Eugenijus; Pira, Nello Li; Sinopoli, Stefano; Račiukaitis, Gediminas
2017-08-01
Moulded interconnect devices (MID) offer the material, weight and cost saving by integration electronic circuits directly into polymeric components used in automotive and other consumer products. Lasers are used to write circuits directly by modifying the surface of polymers followed by an electroless metal plating. A new composite material - the polypropylene doped with multiwall carbon nanotubes was developed for the laser-induced selective metallization. Mechanism of surface activation by laser irradiation was investigated in details utilising pico- and nanoseconds lasers. Deposition of copper was performed in the autocatalytic electroless plating bath. The laser-activated polymer surfaces have been studied using the Raman spectroscopy and scanning electron microscope (SEM). Microscopic images revealed that surface becomes active only after its melting by a laser. Alterations in the Raman spectra of the D and G bands indicated the clustering of carbon additives in the composite material. Optimal laser parameters for the surface activation were found by measuring a sheet resistance of the finally metal-plated samples. A spatially selective copper plating was achieved with the smallest conductor line width of 22 μm at the laser scanning speed of 3 m/s and the pulse repetition rate of 100 kHz. Finally, the technique was validated by making functional electronic circuits by this MID approach.
Reese, Tiffany A.; Bi, Kevin; Kambal, Amal; Filali-Mouhim, Ali; Beura, Lalit K.; Bürger, Matheus C.; Pulendran, Bali; Sekaly, Rafick; Jameson, Stephen C.; Masopust, David; Haining, W. Nicholas; Virgin, Herbert W.
2016-01-01
Summary Immune responses differ between laboratory mice and humans. Chronic infection with viruses and parasites are common in humans, but are absent in laboratory mice, and thus represent potential contributors to inter-species differences in immunity. To test this, we sequentially infected laboratory mice with herpesviruses, influenza, and an intestinal helminth, and compared their blood immune signatures to mock-infected mice before and after vaccination against Yellow Fever Virus (YFV-17D). Sequential infection altered pre- and post-vaccination gene expression, cytokines, and antibodies in blood. Sequential pathogen exposure induced gene signatures that recapitulated those seen in blood from pet store-raised versus laboratory mice, and adult versus cord blood in humans. Therefore basal and vaccine-induced murine immune responses are altered by infection with agents common outside of barrier facilities. This raises the possibility that we can improve mouse models of vaccination and immunity by selective microbial exposure of laboratory animals to mimic that of humans. PMID:27107939
Three parameters optimizing closed-loop control in sequential segmental neuromuscular stimulation.
Zonnevijlle, E D; Somia, N N; Perez Abadia, G; Stremel, R W; Maldonado, C J; Werker, P M; Kon, M; Barker, J H
1999-05-01
In conventional dynamic myoplasties, the force generation is poorly controlled. This causes unnecessary fatigue of the transposed/transplanted electrically stimulated muscles and causes damage to the involved tissues. We introduced sequential segmental neuromuscular stimulation (SSNS) to reduce muscle fatigue by allowing part of the muscle to rest periodically while the other parts work. Despite this improvement, we hypothesize that fatigue could be further reduced in some applications of dynamic myoplasty if the muscles were made to contract according to need. The first necessary step is to gain appropriate control over the contractile activity of the dynamic myoplasty. Therefore, closed-loop control was tested on a sequentially stimulated neosphincter to strive for the best possible control over the amount of generated pressure. A selection of parameters was validated for optimizing control. We concluded that the frequency of corrections, the threshold for corrections, and the transition time are meaningful parameters in the controlling algorithm of the closed-loop control in a sequentially stimulated myoplasty.
Blocking for Sequential Political Experiments
Moore, Sally A.
2013-01-01
In typical political experiments, researchers randomize a set of households, precincts, or individuals to treatments all at once, and characteristics of all units are known at the time of randomization. However, in many other experiments, subjects “trickle in” to be randomized to treatment conditions, usually via complete randomization. To take advantage of the rich background data that researchers often have (but underutilize) in these experiments, we develop methods that use continuous covariates to assign treatments sequentially. We build on biased coin and minimization procedures for discrete covariates and demonstrate that our methods outperform complete randomization, producing better covariate balance in simulated data. We then describe how we selected and deployed a sequential blocking method in a clinical trial and demonstrate the advantages of our having done so. Further, we show how that method would have performed in two larger sequential political trials. Finally, we compare causal effect estimates from differences in means, augmented inverse propensity weighted estimators, and randomization test inversion. PMID:24143061
Middlebrooks, Catherine D; Castel, Alan D
2018-05-01
Learners make a number of decisions when attempting to study efficiently: they must choose which information to study, for how long to study it, and whether to restudy it later. The current experiments examine whether documented impairments to self-regulated learning when studying information sequentially, as opposed to simultaneously, extend to the learning of and memory for valuable information. In Experiment 1, participants studied lists of words ranging in value from 1-10 points sequentially or simultaneously at a preset presentation rate; in Experiment 2, study was self-paced and participants could choose to restudy. Although participants prioritized high-value over low-value information, irrespective of presentation, those who studied the items simultaneously demonstrated superior value-based prioritization with respect to recall, study selections, and self-pacing. The results of the present experiments support the theory that devising, maintaining, and executing efficient study agendas is inherently different under sequential formatting than simultaneous. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Singh, Rupesh; Rajaraman, Srinivas; Balasubramanian, Madhusudhanan
2017-10-01
A novel nanoparticle mediated methodology for laser photocoagulation of the inner retina to achieve tissue selective treatment is presented. Transport of 527, 577, and 810 nm laser, heat deposition, and eventual thermal damage in vitreous, retina, RPE, choroid, and sclera were modeled using Bouguer-Beer-Lambert law of absorption and solved numerically using the finite volume method. Nanoparticles were designed using Mie theory of scattering. Performance of the new photocoagulation strategy using gold nanospheres and gold-silica nanoshells was compared with that of conventional methods without nanoparticles. For experimental validation, vitreous cavity of ex vivo porcine eyes was infused with gold nanospheres. After ~6 h of nanoparticle diffusion, the porcine retina was irradiated with a green laser and imaged simultaneously using a spectral domain optical coherence tomography (Spectralis SD-OCT, Heidelberg Engineering). Our computational model predicted a significant spatial shift in the peak temperature from RPE to the inner retinal region when infused with nanoparticles. Arrhenius thermal damage in the mid-retinal location was achieved in ~14 ms for 527 nm laser thereby reducing the irradiation duration by ~30 ms compared with the treatment without nanoparticles. In ex vivo porcine eyes infused with gold nanospheres, SD-OCT retinal images revealed a lower thermal damage and expansion at RPE due to laser photocoagulation. Nanoparticle infused laser photocoagulation strategy provided a selective inner retinal thermal damage with significant decrease in laser power and laser exposure time. The proposed treatment strategy shows possibilities for an efficient and highly selective inner retinal laser treatment.
Zacharatos, Filimon; Karvounis, Panagiotis; Theodorakos, Ioannis; Hatziapostolou, Antonios; Zergioti, Ioanna
2018-06-19
Ag nanowire (NW) networks have exquisite optical and electrical properties which make them ideal candidate materials for flexible transparent conductive electrodes. Despite the compatibility of Ag NW networks with laser processing, few demonstrations of laser fabricated Ag NW based components currently exist. In this work, we report on a novel single step laser transferring and laser curing process of micrometer sized pixels of Ag NW networks on flexible substrates. This process relies on the selective laser heating of the Ag NWs induced by the laser pulse energy and the subsequent localized melting of the polymeric substrate. We demonstrate that a single laser pulse can induce both transfer and curing of the Ag NW network. The feasibility of the process is confirmed experimentally and validated by Finite Element Analysis simulations, which indicate that selective heating is carried out within a submicron-sized heat affected zone. The resulting structures can be utilized as fully functional flexible transparent electrodes with figures of merit even higher than 100. Low sheet resistance (<50 Ohm/sq) and high visible light transparency (>90%) make the reported process highly desirable for a variety of applications, including selective heating or annealing of nanocomposite materials and laser processing of nanostructured materials on a large variety of optically transparent substrates, such as Polydimethylsiloxane (PDMS).
A comparison of sequential and spiral scanning techniques in brain CT.
Pace, Ivana; Zarb, Francis
2015-01-01
To evaluate and compare image quality and radiation dose of sequential computed tomography (CT) examinations of the brain and spiral CT examinations of the brain imaged on a GE HiSpeed NX/I Dual Slice 2CT scanner. A random sample of 40 patients referred for CT examination of the brain was selected and divided into 2 groups. Half of the patients were scanned using the sequential technique; the other half were scanned using the spiral technique. Radiation dose data—both the computed tomography dose index (CTDI) and the dose length product (DLP)—were recorded on a checklist at the end of each examination. Using the European Guidelines on Quality Criteria for Computed Tomography, 4 radiologists conducted a visual grading analysis and rated the level of visibility of 6 anatomical structures considered necessary to produce images of high quality. The mean CTDI(vol) and DLP values were statistically significantly higher (P <.05) with the sequential scans (CTDI(vol): 22.06 mGy; DLP: 304.60 mGy • cm) than with the spiral scans (CTDI(vol): 14.94 mGy; DLP: 229.10 mGy • cm). The mean image quality rating scores for all criteria of the sequential scanning technique were statistically significantly higher (P <.05) in the visual grading analysis than those of the spiral scanning technique. In this local study, the sequential technique was preferred over the spiral technique for both overall image quality and differentiation between gray and white matter in brain CT scans. Other similar studies counter this finding. The radiation dose seen with the sequential CT scanning technique was significantly higher than that seen with the spiral CT scanning technique. However, image quality with the sequential technique was statistically significantly superior (P <.05).
Method and apparatus for chemical and topographical microanalysis
NASA Technical Reports Server (NTRS)
Kossakovski, Dmitri A. (Inventor); Baldeschwieler, John D. (Inventor); Beauchamp, Jesse L. (Inventor)
2002-01-01
A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.
Boessen, Ruud; van der Baan, Frederieke; Groenwold, Rolf; Egberts, Antoine; Klungel, Olaf; Grobbee, Diederick; Knol, Mirjam; Roes, Kit
2013-01-01
Two-stage clinical trial designs may be efficient in pharmacogenetics research when there is some but inconclusive evidence of effect modification by a genomic marker. Two-stage designs allow to stop early for efficacy or futility and can offer the additional opportunity to enrich the study population to a specific patient subgroup after an interim analysis. This study compared sample size requirements for fixed parallel group, group sequential, and adaptive selection designs with equal overall power and control of the family-wise type I error rate. The designs were evaluated across scenarios that defined the effect sizes in the marker positive and marker negative subgroups and the prevalence of marker positive patients in the overall study population. Effect sizes were chosen to reflect realistic planning scenarios, where at least some effect is present in the marker negative subgroup. In addition, scenarios were considered in which the assumed 'true' subgroup effects (i.e., the postulated effects) differed from those hypothesized at the planning stage. As expected, both two-stage designs generally required fewer patients than a fixed parallel group design, and the advantage increased as the difference between subgroups increased. The adaptive selection design added little further reduction in sample size, as compared with the group sequential design, when the postulated effect sizes were equal to those hypothesized at the planning stage. However, when the postulated effects deviated strongly in favor of enrichment, the comparative advantage of the adaptive selection design increased, which precisely reflects the adaptive nature of the design. Copyright © 2013 John Wiley & Sons, Ltd.
Laser altimetry simulator. Version 3.0: User's guide
NASA Technical Reports Server (NTRS)
Abshire, James B.; Mcgarry, Jan F.; Pacini, Linda K.; Blair, J. Bryan; Elman, Gregory C.
1994-01-01
A numerical simulator of a pulsed, direct detection laser altimeter has been developed to investigate the performance of space-based laser altimeters operating over surfaces with various height profiles. The simulator calculates the laser's optical intensity waveform as it propagates to and is reflected from the terrain surface and is collected by the receiver telescope. It also calculates the signal and noise waveforms output from the receiver's optical detector and waveform digitizer. Both avalanche photodiode and photomultiplier detectors may be selected. Parameters of the detected signal, including energy, the 50 percent rise-time point, the mean timing point, and the centroid, can be collected into histograms and statistics calculated after a number of laser firings. The laser altimeter can be selected to be fixed over the terrain at any altitude. Alternatively, it can move between laser shots to simulate the terrain profile measured with the laser altimeter.
Construction and Characterization of External Cavity Diode Lasers for Atomic Physics
Hardman, Kyle S.; Bennetts, Shayne; Debs, John E.; Kuhn, Carlos C. N.; McDonald, Gordon D.; Robins, Nick
2014-01-01
Since their development in the late 1980s, cheap, reliable external cavity diode lasers (ECDLs) have replaced complex and expensive traditional dye and Titanium Sapphire lasers as the workhorse laser of atomic physics labs1,2. Their versatility and prolific use throughout atomic physics in applications such as absorption spectroscopy and laser cooling1,2 makes it imperative for incoming students to gain a firm practical understanding of these lasers. This publication builds upon the seminal work by Wieman3, updating components, and providing a video tutorial. The setup, frequency locking and performance characterization of an ECDL will be described. Discussion of component selection and proper mounting of both diodes and gratings, the factors affecting mode selection within the cavity, proper alignment for optimal external feedback, optics setup for coarse and fine frequency sensitive measurements, a brief overview of laser locking techniques, and laser linewidth measurements are included. PMID:24796259
Construction and characterization of external cavity diode lasers for atomic physics.
Hardman, Kyle S; Bennetts, Shayne; Debs, John E; Kuhn, Carlos C N; McDonald, Gordon D; Robins, Nick
2014-04-24
Since their development in the late 1980s, cheap, reliable external cavity diode lasers (ECDLs) have replaced complex and expensive traditional dye and Titanium Sapphire lasers as the workhorse laser of atomic physics labs. Their versatility and prolific use throughout atomic physics in applications such as absorption spectroscopy and laser cooling makes it imperative for incoming students to gain a firm practical understanding of these lasers. This publication builds upon the seminal work by Wieman, updating components, and providing a video tutorial. The setup, frequency locking and performance characterization of an ECDL will be described. Discussion of component selection and proper mounting of both diodes and gratings, the factors affecting mode selection within the cavity, proper alignment for optimal external feedback, optics setup for coarse and fine frequency sensitive measurements, a brief overview of laser locking techniques, and laser linewidth measurements are included.
Sequential Tool Use in Great Apes
Martin-Ordas, Gema; Schumacher, Lena; Call, Josep
2012-01-01
Sequential tool use is defined as using a tool to obtain another non-food object which subsequently itself will serve as a tool to act upon a further (sub)goal. Previous studies have shown that birds and great apes succeed in such tasks. However, the inclusion of a training phase for each of the sequential steps and the low cost associated with retrieving the longest tools limits the scope of the conclusions. The goal of the experiments presented here was, first to replicate a previous study on sequential tool use conducted on New Caledonian crows and, second, extend this work by increasing the cost of retrieving a tool in order to test tool selectivity of apes. In Experiment 1, we presented chimpanzees, orangutans and bonobos with an out-of-reach reward, two tools that were available but too short to reach the food and four out-of-reach tools differing in functionality. Similar to crows, apes spontaneously used up to 3 tools in sequence to get the reward and also showed a strong preference for the longest out-of reach tool independently of the distance of the food. In Experiment 2, we increased the cost of reaching for the longest out-of reach tool. Now apes used up to 5 tools in sequence to get the reward and became more selective in their choice of the longest tool as the costs of its retrieval increased. The findings of the studies presented here contribute to the growing body of comparative research on tool use. PMID:23300592
Laser treatment of port-wine stains
Brightman, Lori A; Geronemus, Roy G; Reddy, Kavitha K
2015-01-01
Port-wine stains are a type of capillary malformation affecting 0.3% to 0.5% of the population. Port-wine stains present at birth as pink to erythematous patches on the skin and/or mucosa. Without treatment, the patches typically darken with age and may eventually develop nodular thickening or associated pyogenic granuloma. Laser and light treatments provide improvement through selective destruction of vasculature. A variety of vascular-selective lasers may be employed, with the pulsed dye laser being the most common and well studied. Early treatment produces more optimal results. Advances in imaging and laser treatment technologies demonstrate potential to further improve clinical outcomes. PMID:25624768
Controlling laser emission by selecting crystal orientation
NASA Astrophysics Data System (ADS)
Chen, Lijuan; Han, Shujuan; Wang, Zhengping; Wang, Jiyang; Zhang, Huanjin; Yu, Haohai; Han, Shuo; Xu, Xinguang
2013-01-01
Based on the anisotropy of laser crystal, we demonstrate a method of adjusting laser emission by selecting crystal orientation. When the light propagating direction varies from a to c axis of Nd:LiGd(MoO4)2 crystal, emission wavelength exhibits a sensitive change of 1061 nm → 1061/1062 + 1068 nm → 1068 nm. The experimental discipline is well explained by a theoretical study of simulating on the spatial distribution of stimulated emission cross-section. This letter manifests that the laser property along non-principal-axis direction is also valuable for research and application, which breaks through the traditional custom of using laser materials processed along principal-axis.
Laser furnace and method for zone refining of semiconductor wafers
NASA Technical Reports Server (NTRS)
Griner, Donald B. (Inventor); zur Burg, Frederick W. (Inventor); Penn, Wayne M. (Inventor)
1988-01-01
A method of zone refining a crystal wafer (116 FIG. 1) comprising the steps of focusing a laser beam to a small spot (120) of selectable size on the surface of the crystal wafer (116) to melt a spot on the crystal wafer, scanning the small laser beam spot back and forth across the surface of the crystal wafer (116) at a constant velocity, and moving the scanning laser beam across a predetermined zone of the surface of the crystal wafer (116) in a direction normal to the laser beam scanning direction and at a selectible velocity to melt and refine the entire crystal wafer (116).
Parameter optimization for selective laser melting of TiAl6V4 alloy by CO2 laser
NASA Astrophysics Data System (ADS)
Baitimerov, R. M.; Lykov, P. A.; Radionova, L. V.; Safonov, E. V.
2017-10-01
TiAl6V4 alloy is one of the widely used materials in powder bed fusion additive manufacturing technologies. In recent years selective laser melting (SLM) of TiAl6V4 alloy by fiber laser has been well studied, but SLM by CO2-lasers has not. SLM of TiAl6V4 powder by CO2-laser was studied in this paper. Nine 10×10×10 mm cubic specimens were fabricated using different SLM process parameters. All of the fabricated specimens have a good dense structure and a good surface finish quality without dimensional distortion. The lowest porosity that was achieved was about 0.5%.
Laser ablation of dental calculus at 400 nm using a Ti:sapphire laser
NASA Astrophysics Data System (ADS)
Schoenly, Joshua E.; Seka, Wolf; Rechmann, Peter
2009-02-01
A Nd:YAG laser-pumped, frequency-doubled Ti:sapphire laser is used for selective ablation of calculus. The laser provides <=25 mJ at 400 nm (60-ns pulse width, 10-Hz repetition rate). The laser is coupled into an optical multimode fiber coiled around a 4-in.-diam drum to generate a top-hat output intensity profile. With coaxial water cooling, this is ideal for efficient, selective calculus removal. This is in stark contrast with tightly focused Gaussian beams that are energetically inefficient and lead to irreproducible results. Calculus is well ablated at high fluences >=2J/cm2 stalling occurs below this fluence because of photobleaching. Healthy hard tissue is not removed at fluences <=3 J/cm2.
Pang, Xuming; Wei, Qian; Zhou, Jianxin; Ma, Huiyang
2018-06-19
In order to achieve cermet-based solar absorber coatings with long-term thermal stability at high temperatures, a novel single-layer, multi-scale TiC-Ni/Mo cermet coating was first prepared using laser cladding technology in atmosphere. The results show that the optical properties of the cermet coatings using laser cladding were much better than the preplaced coating. In addition, the thermal stability of the optical properties for the laser cladding coating were excellent after annealing at 650 °C for 200 h. The solar absorptance and thermal emittance of multi-scale cermet coating were 85% and 4.7% at 650 °C. The results show that multi-scale cermet materials are more suitable for solar-selective absorbing coating. In addition, laser cladding is a new technology that can be used for the preparation of spectrally-selective coatings.
Wansard, Murielle; Bartolomeo, Paolo; Bastin, Christine; Segovia, Fermín; Gillet, Sophie; Duret, Christophe; Meulemans, Thierry
2015-01-01
Over the last decade, many studies have demonstrated that visuospatial working memory (VSWM) can be divided into separate subsystems dedicated to the retention of visual patterns and their serial order. Impaired VSWM has been suggested to exacerbate left visual neglect in right-brain-damaged individuals. The aim of this study was to investigate the segregation between spatial-sequential and spatial-simultaneous working memory in individuals with neglect. We demonstrated that patterns of results on these VSWM tasks can be dissociated. Spatial-simultaneous and sequential aspects of VSWM can be selectively impaired in unilateral neglect. Our results support the hypothesis of multiple VSWM subsystems, which should be taken into account to better understand neglect-related deficits.
Multisensor-based human detection and tracking for mobile service robots.
Bellotto, Nicola; Hu, Huosheng
2009-02-01
One of fundamental issues for service robots is human-robot interaction. In order to perform such a task and provide the desired services, these robots need to detect and track people in the surroundings. In this paper, we propose a solution for human tracking with a mobile robot that implements multisensor data fusion techniques. The system utilizes a new algorithm for laser-based leg detection using the onboard laser range finder (LRF). The approach is based on the recognition of typical leg patterns extracted from laser scans, which are shown to also be very discriminative in cluttered environments. These patterns can be used to localize both static and walking persons, even when the robot moves. Furthermore, faces are detected using the robot's camera, and the information is fused to the legs' position using a sequential implementation of unscented Kalman filter. The proposed solution is feasible for service robots with a similar device configuration and has been successfully implemented on two different mobile platforms. Several experiments illustrate the effectiveness of our approach, showing that robust human tracking can be performed within complex indoor environments.
Review of selective laser melting: Materials and applications
NASA Astrophysics Data System (ADS)
Yap, C. Y.; Chua, C. K.; Dong, Z. L.; Liu, Z. H.; Zhang, D. Q.; Loh, L. E.; Sing, S. L.
2015-12-01
Selective Laser Melting (SLM) is a particular rapid prototyping, 3D printing, or Additive Manufacturing (AM) technique designed to use high power-density laser to melt and fuse metallic powders. A component is built by selectively melting and fusing powders within and between layers. The SLM technique is also commonly known as direct selective laser sintering, LaserCusing, and direct metal laser sintering, and this technique has been proven to produce near net-shape parts up to 99.9% relative density. This enables the process to build near full density functional parts and has viable economic benefits. Recent developments of fibre optics and high-power laser have also enabled SLM to process different metallic materials, such as copper, aluminium, and tungsten. Similarly, this has also opened up research opportunities in SLM of ceramic and composite materials. The review presents the SLM process and some of the common physical phenomena associated with this AM technology. It then focuses on the following areas: (a) applications of SLM materials and (b) mechanical properties of SLM parts achieved in research publications. The review is not meant to put a ceiling on the capabilities of the SLM process but to enable readers to have an overview on the material properties achieved by the SLM process so far. Trends in research of SLM are also elaborated in the last section.
Zhang, Guobo; Chen, Min; Liu, Feng; Yuan, Xiaohui; Weng, Suming; Zheng, Jun; Ma, Yanyun; Shao, Fuqiu; Sheng, Zhengming; Zhang, Jie
2017-10-02
Relativistically intense laser solid target interaction has been proved to be a promising way to generate high-order harmonics, which can be used to diagnose ultrafast phenomena. However, their emission direction and spectra still lack tunability. Based upon two-dimensional particle-in-cell simulations, we show that directional enhancement of selected high-order-harmonics can be realized using blazed grating targets. Such targets can select harmonics with frequencies being integer times of the grating frequency. Meanwhile, the radiation intensity and emission area of the harmonics are increased. The emission direction is controlled by tailoring the local blazed structure. Theoretical and electron dynamics analysis for harmonics generation, selection and directional enhancement from the interaction between multi-cycle laser and grating target are carried out. These studies will benefit the generation and application of laser plasma-based high order harmonics.
Pulse Width Dependence Of Pigment Cell Damage At 694 nm In Guinea Pig Skin
NASA Astrophysics Data System (ADS)
Dover, Jeffrey S.; Polla, Luigi L.; Margolis, Randall J.; Whitaker, Diana; Watanabe, Schinichi; Murphy, George F.; Parrish, John A.; Anderson, R. R.
1987-03-01
351 nm, 20-nsec XeF excimer laser irradiation has previously been shown to selectively target and damage melanosomes in human skin. In the following studies selective targeting with melanosomal photodisruption has been demonstrated in pigmented guinea pig skin with a Q-switched 40-nsec ruby laser, and a 750-nsec pulsed dye laser but not with a 400-usec pulsed dye laser. The pulse width dependence of melanosomal disruption, occurring only at pulsewidths shorter than the thermal relaxation time of the melanosome (0.5 - 1.0 usec), is in accordance with the theory of selective photothermolysis. Possible mechanisms of melanosomal photodisruption include development of sudden thermal gradients leading to cavitation or shock wave production.
Improved solution accuracy for TDRSS-based TOPEX/Poseidon orbit determination
NASA Technical Reports Server (NTRS)
Doll, C. E.; Mistretta, G. D.; Hart, R. C.; Oza, D. H.; Bolvin, D. T.; Cox, C. M.; Nemesure, M.; Niklewski, D. J.; Samii, M. V.
1994-01-01
Orbit determination results are obtained by the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) using a batch-least-squares estimator available in the Goddard Trajectory Determination System (GTDS) and an extended Kalman filter estimation system to process Tracking and Data Relay Satellite (TDRS) System (TDRSS) measurements. GTDS is the operational orbit determination system used by the FDD in support of the Ocean Topography Experiment (TOPEX)/Poseidon spacecraft navigation and health and safety operations. The extended Kalman filter was implemented in an orbit determination analysis prototype system, closely related to the Real-Time Orbit Determination System/Enhanced (RTOD/E) system. In addition, the Precision Orbit Determination (POD) team within the GSFC Space Geodesy Branch generated an independent set of high-accuracy trajectories to support the TOPEX/Poseidon scientific data. These latter solutions use the geodynamics (GEODYN) orbit determination system with laser ranging and Doppler Orbitography and Radiopositioning integrated by satellite (DORIS) tracking measurements. The TOPEX/Poseidon trajectories were estimated for November 7 through November 11, 1992, the timeframe under study. Independent assessments were made of the consistencies of solutions produced by the batch and sequential methods. The batch-least-squares solutions were assessed based on the solution residuals, while the sequential solutions were assessed based on primarily the estimated covariances. The batch-least-squares and sequential orbit solutions were compared with the definitive POD orbit solutions. The solution differences were generally less than 2 meters for the batch-least-squares and less than 13 meters for the sequential estimation solutions. After the sequential estimation solutions were processed with a smoother algorithm, position differences with POD orbit solutions of less than 7 meters were obtained. The differences among the POD, GTDS, and filter/smoother solutions can be traced to differences in modeling and tracking data types, which are being analyzed in detail.
Tachikawa, Mariko; Yamanaka, Kenzo
2014-11-01
Synergistic disinfection and removal of biofilms by ozone (O3) water in combination with hydrogen peroxide (H2O2) solution was studied by determining disinfection rates and observing changes of the biofilm structure in situ by confocal laser scanning microscopy (CLSM) using an established biofilm of Pseudomonas fluorescence. The sequential treatment with O3, 1.0-1.7 mg/L, followed by H2O2, 0.8-1.1%, showed synergistic disinfection effects, while the reversed treatment, first H2O2 followed by O3, showed only an additive effect. The decrease of synergistic disinfection effect by addition of methanol (CH3OH), a scavenger of hydroxyl radical (OH), into the H2O2 solution suggested generation of hydroxyl radicals on or in the biofilm by the sequential treatment with O3 followed by H2O2. The primary treatment with O3 increased disinfection rates of H2O2 in the secondary treatment, and the increase of O3 concentration enhanced the rates. The cold temperature of O3 water (14 °C and 8 °C) increased the synergistic effect, suggesting the increase of O3 adsorption and hydroxyl radical generation in the biofilm. CLSM observation showed that the sequential treatment, first with O3 followed by H2O2, loosened the cell connections and thinned the extracellular polysaccharides (EPS) in the biofilm. The hydroxyl radical generation in the biofilm may affect the EPS and biofilm structure and may induce effective disinfection with H2O2. This sequential treatment method may suggest a new practical procedure for disinfection and removal of biofilms by inorganic oxidants such as O3 and H2O2. Copyright © 2014 Elsevier Ltd. All rights reserved.
Physics in Europe--A Data File of Selected Research.
1984-06-18
Negev Sapir Proc. 16th Euro. Conf. on Laser Interac. with Matter, London 26-30 Sept. 1983 1025 CPBICF laser plasma soft x-ray refractometry France...CPBICF laser plasma Schlieren diagnostic France 623 CPBICF laser plasma self focusing numerics UK 1025 CPBICF laser plasma soft x-ray refractometry
Microstructure and Magnetic Properties of Magnetic Material Fabricated by Selective Laser Melting
NASA Astrophysics Data System (ADS)
Jhong, Kai Jyun; Huang, Wei-Chin; Lee, Wen Hsi
Selective Laser Melting (SLM) is a powder-based additive manufacturing which is capable of producing parts layer-by-layer from a 3D CAD model. The aim of this study is to adopt the selective laser melting technique to magnetic material fabrication. [1]For the SLM process to be practical in industrial use, highly specific mechanical properties of the final product must be achieved. The integrity of the manufactured components depend strongly on each single laser-melted track and every single layer, as well as the strength of the connections between them. In this study, effects of the processing parameters, such as the space distance of surface morphology is analyzed. Our hypothesis is that when a magnetic product is made by the selective laser melting techniques instead of traditional techniques, the finished component will have more precise and effective properties. This study analyzed the magnitudes of magnetic properties in comparison with different parameters in the SLM process and compiled a completed product to investigate the efficiency in contrast with products made with existing manufacturing processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haglund, R.F.; Tolk, N.H.
The Medical Free Electron Laser Program was awarded to develop, construct and operate a free-electron laser facility dedicated to biomedical and materials studies, with particular emphases on: fundamental studies of absorption and localization of electromagnetic energy on and near material surfaces, especially through electronic and other selective, non-statistical processes; non-thermal photon-materials interactions (e.g., electronic bond-breaking or vibrational energy transfer) in physical and biological materials as well as in long-wavelength biopolymer dynamics; development of FEL-based methods to study drug action and to characterize biomolecular properties and metabolic processes in biomembranes; clinical applications in otolaryngology, neurosurgery, ophthalmology and radiology stressing the usemore » of the laser for selective laser-tissue, laser-cellular and laser-molecule interactions in both therapeutic and diagnostic modalities.« less
Working set selection using functional gain for LS-SVM.
Bo, Liefeng; Jiao, Licheng; Wang, Ling
2007-09-01
The efficiency of sequential minimal optimization (SMO) depends strongly on the working set selection. This letter shows how the improvement of SMO in each iteration, named the functional gain (FG), is used to select the working set for least squares support vector machine (LS-SVM). We prove the convergence of the proposed method and give some theoretical support for its performance. Empirical comparisons demonstrate that our method is superior to the maximum violating pair (MVP) working set selection.
Low-pressure sequential compression of lower limbs enhances forearm skin blood flow.
Amah, Guy; Voicu, Sebastian; Bonnin, Philippe; Kubis, Nathalie
2016-12-01
We investigated whether forearm skin blood flow could be improved when a multilayer pulsatile inflatable suit was applied at a low pressure to the lower limbs and abdomen. We hypothesized that a non-invasive purely mechanical stimulation of the lower limbs could induce remote forearm blood flow modifications. The pulsatile suit induced a sequential compartmentalized low compression (65 mmHg), which was synchronized with each diastole of the cardiac cycle with each phase evolving centripetally (lower limbs to abdomen). Modifications of the forearm skin blood flow were continuously recorded by laser Doppler flowmetry (LDF) at baseline and during the pulsatile suit application. Endothelium-dependent and endothelium-independent vasodilations of the forearm skin microcirculation were measured by LDF in response to a local transdermal iontophoretic application of acetylcholine (ACh-test) and to hyperthermia (hyperT- test). Twenty-four healthy volunteers, 12 men and 12 women (43±14 years) were included in the study. LDF responses increased 1) under pulsatile suit (97±106%, p.
NASA Astrophysics Data System (ADS)
Kusuma, Chandrakanth; Ahmed, Sazzad H.; Mian, Ahsan; Srinivasan, Raghavan
2017-07-01
Selective laser melting (SLM) is an additive manufacturing technique that creates complex parts by selectively melting metal powder layer-by-layer using a laser. In SLM, the process parameters decide the quality of the fabricated component. In this study, single beads of commercially pure titanium (CP-Ti) were melted on a substrate of the same material using an in-house built SLM machine. Multiple combinations of laser power and scan speed were used for single bead fabrication, while the laser beam diameter and powder layer thickness were kept constant. This experimental study investigated the influence of laser power, scan speed, and laser energy density on the melt pool formation, surface morphology, geometry (width and height), and hardness of solidified beads. In addition, the observed unfavorable effect such as inconsistency in melt pool width formation is discussed. The results show that the quality, geometry, and hardness of solidified melt pool are significantly affected by laser power, scanning speed, and laser energy density.
Analysis of filter tuning techniques for sequential orbit determination
NASA Technical Reports Server (NTRS)
Lee, T.; Yee, C.; Oza, D.
1995-01-01
This paper examines filter tuning techniques for a sequential orbit determination (OD) covariance analysis. Recently, there has been a renewed interest in sequential OD, primarily due to the successful flight qualification of the Tracking and Data Relay Satellite System (TDRSS) Onboard Navigation System (TONS) using Doppler data extracted onboard the Extreme Ultraviolet Explorer (EUVE) spacecraft. TONS computes highly accurate orbit solutions onboard the spacecraft in realtime using a sequential filter. As the result of the successful TONS-EUVE flight qualification experiment, the Earth Observing System (EOS) AM-1 Project has selected TONS as the prime navigation system. In addition, sequential OD methods can be used successfully for ground OD. Whether data are processed onboard or on the ground, a sequential OD procedure is generally favored over a batch technique when a realtime automated OD system is desired. Recently, OD covariance analyses were performed for the TONS-EUVE and TONS-EOS missions using the sequential processing options of the Orbit Determination Error Analysis System (ODEAS). ODEAS is the primary covariance analysis system used by the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD). The results of these analyses revealed a high sensitivity of the OD solutions to the state process noise filter tuning parameters. The covariance analysis results show that the state estimate error contributions from measurement-related error sources, especially those due to the random noise and satellite-to-satellite ionospheric refraction correction errors, increase rapidly as the state process noise increases. These results prompted an in-depth investigation of the role of the filter tuning parameters in sequential OD covariance analysis. This paper analyzes how the spacecraft state estimate errors due to dynamic and measurement-related error sources are affected by the process noise level used. This information is then used to establish guidelines for determining optimal filter tuning parameters in a given sequential OD scenario for both covariance analysis and actual OD. Comparisons are also made with corresponding definitive OD results available from the TONS-EUVE analysis.
Broadhurst, Matthew S; Akst, Lee M; Burns, James A; Kobler, James B; Heaton, James T; Anderson, R Rox; Zeitels, Steven M
2007-02-01
Selective vascular ablation (photoangiolysis) using pulsed lasers that target hemoglobin is an effective treatment strategy for many vocal fold lesions. However, vessel rupture with extravasation of blood reduces selectivity for vessels, which is frequently observed with the 0.45-ms, 585-nm pulsed dye laser. Previous studies have shown that vessel rupture is the result of vaporization of blood, an event that varies with laser pulse width and pulse fluence (energy per unit area). Clinical observations using a 532-nm wavelength pulsed potassium-titanyl-phosphate (KTP) laser revealed less laser-induced hemorrhage than the pulsed dye laser. This study investigated settings for the pulsed KTP laser to achieve selective vessel destruction without rupture using the avian chorioallantoic membrane under conditions similar to flexible laryngoscopic delivery of the laser in clinical practice. The chick chorioallantoic membrane offers convenient access to many small blood vessels similar in size to those targeted in human vocal fold. Using a 532-nm pulsed KTP laser, pulse width, pulse energy, and working distance from the optical delivery fiber were varied to assess influence on the ability to achieve vessel coagulation without vessel wall rupture. Third-order vessels (n = 135) were irradiated: Energy (471-550 mJ), pulse width (10, 15, 30 ms), and fiber-to-tissue distance (1 mm, 3 mm) were varied systematically. Selective vessel destruction without vessel wall rupture was more often achieved by increasing pulse width, increasing the fiber-to-tissue distance, and decreasing energy. Vessel destruction without rupture was consistently achieved using 15- or 30-ms pulses with a fiber-to-tissue distance of 3 mm (pulse fluence of 13-16 J/cm). This study substantiates our clinical observation that a 532-nm pulsed KTP laser was effective for ablating microcirculation while minimizing vessel wall rupture and hemorrhage.
Photothermal and photoacoustic processes of laser activated nano-thermolysis of cells
NASA Astrophysics Data System (ADS)
Lapotko, Dmitri; Lukianova, Ekaterina; Mitskevich, Pavel; Smolnikova, Victoria; Potapnev, Michail; Konopleva, Marina; Andreeff, Michael; Oraevsky, Alexander
2007-02-01
Laser Activated Nano-Thermolysis was recently proposed for selective damage of individual target (cancer) cells by pulsed laser induced microbubbles around superheated clusters of optically absorbing nanoparticles (NP). One of the clinical applications of this technology is the elimination of residual tumor cells from human blood and bone marrow. Clinical standards for the safety and efficacy of such procedure require the development and verification of highly selective and controllable mechanisms of cell killing. Our previous experiments showed that laser-induced microbubble is the main damaging factor in the case cell irradiation by short laser pulses above the threshold. Our current aim was to study the cell damage mechanisms and analyze selectivity and efficacy of cell damage as a function of NP parameters, NP-cell interaction conditions, and conditions of bubble generation around NP and NP clusters in cells. Generation of laser-induced bubbles around gold NP with diameters 10-250 nm was studied in Acute Myeloblast Leukemia (AML) cultures, normal stem and model K562 human cells. Short laser pulses (10 ns, 532 nm) were applied to those cells in vitro and the processes in cells were investigated with photothermal, fluorescent and atomic force microscopies and also with fluorescence flow cytometry. We have found that the best selectivity of cell damage is achieved by (1) forming large clusters of optically absorbing NP in target cells and (2) irradiating the cells with single laser pulses with the lowest fluence that can generate microbubble only around large clusters but not around single NP. Laser microbubbles with the lifetime from 20 ns to 2000 ns generated in individual cells caused damage and lysis of the cellular membrane and consequently cell death. Laser microbubbles did not damage normal cells around the damaged target (tumor) cell. Laser irradiation with equal fluence did not cause any damage of cells without accumulated NP clusters.
Lab Demonstration of the Hybrid Doppler Wind Lidar (HDWL) Transceiver
NASA Technical Reports Server (NTRS)
Marx, Catherine T.; Gentry, Bruce; Jordan, Patrick; Dogoda, Peter; Faust, Ed; Kavaya, Michael
2013-01-01
The recommended design approach for the 3D Tropospheric Winds mission is a hybrid Doppler lidar which combines the best elements of both a coherent aerosol Doppler lidar operating at 2 micron and a direct detection molecular Doppler lidar operating at 0.355 micron. In support of the mission, we built a novel, compact, light-weighted multi-field of view transceiver where multiple telescopes are used to cover the required four fields of view. A small mechanism sequentially selects both the "transmit" and "receive" fields of view. The four fields are combined to stimulate both the 0.355 micron receiver and the 2 micron receiver. This version is scaled (0.2 micron diameter aperture) from the space-based version but still demonstrates the feasibility of the hybrid approach. The primary mirrors were conventionally light-weighted and coated with dielectric, high reflectivity coatings with high laser damage thresholds at both 2 micron and 0.355 micron. The mechanical structure and mounts were fabricated from composites to achieve dimensional stability while significantly reducing the mass. In the laboratory, we demonstrated the system level functionality at 0.355 micron and at 2 micron raising the Technology Readiness Level (TRL) from 2 to 4.
Lab Demonstration of the Hybrid Doppler Wind Lidar (HDWL) Transceiver
NASA Technical Reports Server (NTRS)
Marx, Catherine T.; Gentry, Bruce; Jordan, Patrick; Dogoda, Peter; Faust, Ed; Kavaya, Michael
2013-01-01
The recommended design approach for the 3D Tropospheric Winds mission is a hybrid Doppler lidar which combines the best elements of both a coherent aerosol Doppler lidar operating at 2 microns and a direct detection molecular Doppler lidar operating at 0.355 microns. In support of the mission, we built a novel, compact, light-weighted multi-field of view transceiver where multiple telescopes are used to cover the required four fields of view. A small mechanism sequentially selects both the "transmit" and "receive" fields of view. The four fields are combined to stimulate both the 0.355 micron receiver and the 2 micron receiver. This version is scaled (0.2 m diameter aperture) from the space-based version but still demonstrates the feasibility of the hybrid approach. The primary mirrors were conventionally light-weighted and coated with dielectric, high reflectivity coatings with high laser damage thresholds at both 2 microns and 0.355 microns. The mechanical structure and mounts were fabricated from composites to achieve dimensional stability while significantly reducing the mass. In the laboratory, we demonstrated the system level functionality at 0.355 microns and at 2 microns, raising the Technology Readiness Level (TRL) from 2 to 4.
NASA Astrophysics Data System (ADS)
Nehrir, A. R.; Repasky, K. S.; Carlsten, J.; Ismail, S.
2011-12-01
Measurements of real-time high spatial and temporal resolution profiles of combined water vapor and aerosols in the boundary layer have been a long standing observational challenge to the meteorological, weather forecasting, and climate science communities. To overcome the high reoccurring costs associated with radiosondes as well as the lack of sufficient water vapor measurements over the continental united states, a compact and low cost eye-safe all semiconductor-based micro-pulse differential absorption lidar (DIAL) has been developed for water vapor and aerosol profiling in the lower troposphere. The laser transmitter utilizes two continuous wave external cavity diode lasers operating in the 830 nm absorption band as the online and offline seed laser sources. An optical switch is used to sequentially injection seed a tapered semiconductor optical amplifier (TSOA) with the two seed laser sources in a master oscillator power amplifier (MOPA) configuration. The TSOA is actively current pulsed to produce up to 7 μJ of output energy over a 1 μs pulse duration (150 m vertical resolution) at a 10 kHz pulse repetition frequency. The measured laser transmitter spectral linewidth is less than 500 kHz while the long term frequency stability of the stabilized on-line wavelength is ± 55 MHz. The laser transmitter spectral purity was measured to be greater than 0.9996, allowing for simultaneous measurements of water vapor in the lower and upper troposphere. The DIAL receiver utilizes a commercially available full sky-scanning capable 35 cm Schmidt-Cassegrain telescope to collect the scattered light from the laser transmitter. Light collected by the telescope is spectrally filtered to suppress background noise and is coupled into a fiber optic cable which acts as the system field stop and limits the full angle field of view to 140 μrad. The light is sampled by a fiber coupled APD operated in a Geiger mode. The DIAL instrument is operated autonomously where water vapor and aerosol profiles are displayed in real-time. The transmitter is capable of operating at any spectral position along the selected water vapor absorption line allowing for year round operation at various geographical locations using a single line. Water vapor and aerosol profiles have been recorded up to 6 km and 15 km with 10 m and 1 m temporal averaging, respectively, allowing for mesoscale monitoring of boundary layer dynamics during both daytime and nighttime operation. A brief description of the current status of the water vapor DIAL instrument will be presented. Nighttime and daytime water vapor and aerosol profiles/inversions from the DIAL instrument will also be presented and favorable comparisons against collocated radiosonde, in situ, and column averaged data from SUOMINET and AERONET will also be discussed. A future outlook towards instrument enhancements that will allow the diode-laser-based DIAL technique/technology to become a viable candidate for deployment in multi-point sensor networks will also be discussed.
Sequential sensory and decision processing in posterior parietal cortex
Ibos, Guilhem; Freedman, David J
2017-01-01
Decisions about the behavioral significance of sensory stimuli often require comparing sensory inference of what we are looking at to internal models of what we are looking for. Here, we test how neuronal selectivity for visual features is transformed into decision-related signals in posterior parietal cortex (area LIP). Monkeys performed a visual matching task that required them to detect target stimuli composed of conjunctions of color and motion-direction. Neuronal recordings from area LIP revealed two main findings. First, the sequential processing of visual features and the selection of target-stimuli suggest that LIP is involved in transforming sensory information into decision-related signals. Second, the patterns of color and motion selectivity and their impact on decision-related encoding suggest that LIP plays a role in detecting target stimuli by comparing bottom-up sensory inputs (what the monkeys were looking at) and top-down cognitive encoding inputs (what the monkeys were looking for). DOI: http://dx.doi.org/10.7554/eLife.23743.001 PMID:28418332
NASA Astrophysics Data System (ADS)
Saprykin, A. A.; Sharkeev, Yu P.; Ibragimov, E. A.; Babakova, E. V.; Dudikhin, D. V.
2016-07-01
Alloys based on the titanium-niobium system are widely used in implant production. It is conditional, first of all, on the low modulus of elasticity and bio-inert properties of an alloy. These alloys are especially important for tooth replacement and orthopedic surgery. At present alloys based on the titanium-niobium system are produced mainly using conventional metallurgical methods. The further subtractive manufacturing an end product results in a lot of wastes, increasing, therefore, its cost. The alternative of these processes is additive manufacturing. Selective laser melting is a technology, which makes it possible to synthesize products of metal powders and their blends. The point of this technology is laser melting a layer of a powdered material; then a sintered layer is coated with the next layer of powder etc. Complex products and working prototypes are made on the base of this technology. The authors of this paper address to the issue of applying selective laser melting in order to synthesize a binary alloy of a composite powder based on the titanium-niobium system. A set of 10x10 mm samples is made in various process conditions. The samples are made by an experimental selective laser synthesis machine «VARISKAF-100MB». The machine provides adjustment of the following process variables: laser emission power, scanning rate and pitch, temperature of powder pre-heating, thickness of the layer to be sprinkled, and diameter of laser spot focusing. All samples are made in the preliminary vacuumized shielding atmosphere of argon. The porosity and thickness of the sintered layer related to the laser emission power are shown at various scanning rates. It is revealed that scanning rate and laser emission power are adjustable process variables, having the greatest effect on forming the sintered layer.
Murta, Joaquim N; Rosa, Andreia M; Quadrado, Maria Joao C; Russo, Ana D; Brito, Sergio S; Silva, Maria Fátima L
2013-01-01
To evaluate the use of a femtosecond laser combined with a microkeratome in the preparation of posterior corneal disks for Descemet stripping automated endothelial keratoplasty (DSAEK). This experimental study involved ultrathin DSAEK tissue preparation of 22 donor corneas unsuitable for transplantation. The first cut was performed with an Intralase® FS60 laser and the second cut with a Moria CBm 300-µm microkeratome. The thickness of the first cut was modified for each cornea to obtain a final graft thickness of less than 110 µm. Precut and postcut central pachymetry were performed with an ultrasonic pachymeter. Central endothelial cell density (ECD) was calculated before and 24 hours after tissue preparation. Final graft thickness was 105.0 ± 26.1 (SD) µm (range 65-117). The mean microkeratome head cut thickness was 324.5 ± 10.9 µm (range 310-345). Precut and postcut ECDs averaged 2250 ± 222 and 2093 ± 286 cells/mm2, respectively, representing 6.9% of cell loss. No corneas were perforated. Femtosecond FS60 lasers and Moria CBm 300-µm microkeratomes can be used sequentially to prepare consistently thin DSAEK grafts with no irregular cuts or cornea perforations.
Investigation of X-ray lasers on the SOKOL-P facility at RFNC-VNIITF
NASA Astrophysics Data System (ADS)
Gavrilov, D. S.; Andriyash, A. V.; Vikhlyaev, D. A.; Gorokhov, S. A.; Dmitrov, D. A.; Zapysov, A. L.; Kakshin, A. G.; Kapustin, I. A.; Loboda, E. A.; Lykov, V. A.; Politov, V. Yu.; Potapov, A. V.; Pronin, V. A.; Rykovanov, G. N.; Sukhanov, V. N.; Tischenko, A. S.; Ugodenko, A. A.; Chefonov, O. V.
2007-11-01
The experiments [1] have demonstrated generation of the laser X-radiation (LXR) λ=326A on 3p-3s transitions of Ne-like Ti ions at sequential irradiation of the targets by two laser pulses, focused into a narrow line. The small signal gain equaled 30cm-1. The intensity was 0.5.10^12 W/cm^2 in the prepulse of 0.4ns and 10^14 W/cm^2 in the master pulse of 4ps (delay 1.5 ns). The dependence of LXR yield on the laser energy is demonstrated to have an exponential form. The traveling pumping wave mode was realized using the reflective echelon and the LXR yield is as great as 5-fold. The latest experiments have demonstrated the LXR generation on 4d-4p of Ni-like molybdenum λ=189A. The development of LXR generation model, and numerical codes which allow for the quanta delay effects, quanta refraction in plasma with heavy density gradient, and also the saturation effect have made it possible to describe the experimental dependence of the output LXR yield on the active medium length. Good quantitative agreement is also evident when estimating the output LXR yield on Ne-like Ti ions. [1]Andriyash Quantum Electronics 36 511
Spectrally resolved laser interference microscopy
NASA Astrophysics Data System (ADS)
Butola, Ankit; Ahmad, Azeem; Dubey, Vishesh; Senthilkumaran, P.; Singh Mehta, Dalip
2018-07-01
We developed a new quantitative phase microscopy technique, namely, spectrally resolved laser interference microscopy (SR-LIM), with which it is possible to quantify multi-spectral phase information related to biological specimens without color crosstalk using a color CCD camera. It is a single shot technique where sequential switched on/off of red, green, and blue (RGB) wavelength light sources are not required. The method is implemented using a three-wavelength interference microscope and a customized compact grating based imaging spectrometer fitted at the output port. The results of the USAF resolution chart while employing three different light sources, namely, a halogen lamp, light emitting diodes, and lasers, are discussed and compared. The broadband light sources like the halogen lamp and light emitting diodes lead to stretching in the spectrally decomposed images, whereas it is not observed in the case of narrow-band light sources, i.e. lasers. The proposed technique is further successfully employed for single-shot quantitative phase imaging of human red blood cells at three wavelengths simultaneously without color crosstalk. Using the present technique, one can also use a monochrome camera, even though the experiments are performed using multi-color light sources. Finally, SR-LIM is not only limited to RGB wavelengths, it can be further extended to red, near infra-red, and infra-red wavelengths, which are suitable for various biological applications.
NASA Astrophysics Data System (ADS)
Fortes, Francisco J.; Fernández-Bravo, Angel; Javier Laserna, J.
2014-10-01
Spectral identification of individual micro- and nano-sized particles by the sequential intervention of optical catapulting, optical trapping and laser-induced breakdown spectroscopy is presented. The three techniques are used for different purposes. Optical catapulting (OC) serves to put the particulate material under inspection in aerosol form. Optical trapping (OT) permits the isolation and manipulation of individual particles from the aerosol, which are subsequently analyzed by laser-induced breakdown spectroscopy (LIBS). Once catapulted, the dynamics of particle trapping depends both on the laser beam characteristics (power and intensity gradient) and on the particle properties (size, mass and shape). Particles are stably trapped in air at atmospheric pressure and can be conveniently manipulated for a precise positioning for LIBS analysis. The spectra acquired from the individually trapped particles permit a straightforward identification of the material inspected. Variability of LIBS signal for the inspection of Ni microspheres was 30% relative standard deviation. OC-OT-LIBS permits the separation of particles in a heterogeneous mixture and the subsequent analysis of the isolated particle of interest. In order to evaluate the sensitivity of the approach, the number of absolute photons emitted by a single trapped particle was calculated. The limit of detection (LOD) for Al2O3 particles was calculated to be 200 attograms aluminium.
Laser Sintering Technology and Balling Phenomenon.
Oyar, Perihan
2018-02-01
The aim of this review was to evaluate the balling phenomenon which occurs typically in Selective Laser Sintering (SLS). The balling phenomenon is a typical SLS defect, and observed in laser sintered powder, significantly reduces the quality of SLS, and hinders the further development of SLS Technology. Electronic database searches were performed using Google Scholar. The keywords "laser sintering, selective laser sintering, direct metal laser melting, and balling phenomenon" were searched in title/abstract of publications, limited to December 31, 2016. The inclusion criteria were SLS, balling phenomenon, some alloys (such as Cr-Co, iron, stainless steel, and Cu-based alloys) mechanical properties, microstructure and bond strength between metal-ceramic crown, laboratory studies, full text, and in English language. A total of 100 articles were found the initial search and yielded a total of 50 studies, 30 of which did not fulfill the inclusion criteria and were therefore excluded. In addition, 20 studies were found by screening the reference list of all included publications. Finally, 40 studies were selected for this review. The method in question is regulated by powder material characteristics and the conditions of laser processing. The procedure of formation, affecting factors, and the mechanism of the balling effect are very complex.
Improvement of Speckle Contrast Image Processing by an Efficient Algorithm.
Steimers, A; Farnung, W; Kohl-Bareis, M
2016-01-01
We demonstrate an efficient algorithm for the temporal and spatial based calculation of speckle contrast for the imaging of blood flow by laser speckle contrast analysis (LASCA). It reduces the numerical complexity of necessary calculations, facilitates a multi-core and many-core implementation of the speckle analysis and enables an independence of temporal or spatial resolution and SNR. The new algorithm was evaluated for both spatial and temporal based analysis of speckle patterns with different image sizes and amounts of recruited pixels as sequential, multi-core and many-core code.
Confocal three dimensional tracking of a single nanoparticle with concurrent spectroscopic readouts
NASA Astrophysics Data System (ADS)
Cang, Hu; Wong, Chung M.; Xu, C. Shan; Rizvi, Abbas H.; Yang, Haw
2006-05-01
We present an apparatus that noninvasively tracks a moving nanoparticle in three dimensions while providing concurrent sequential spectroscopic measurements. The design, based on confocal microscopy, uses a near-infrared laser and a dark-field condenser for illumination of a gold nanoparticle. By monitoring the scattered light from the nanoparticle and using a piezoelectric stage, the system was able to continuously bring the diffusive particle in a glycerol/water solution back to the focal volume with spatial resolution and response time of less than 210nm and a millisecond, respectively.
Selective Destruction of Protein Function by Chromophore-Assisted Laser Inactivation
NASA Astrophysics Data System (ADS)
Jay, Daniel G.
1988-08-01
Chromophore-assisted laser inactivation of protein function has been achieved. After a protein binds a specific ligand or antibody conjugated with malachite green (C.I. 42000), it is selectively inactivated by laser irradiation at a wavelength of light absorbed by the dye but not significantly absorbed by cellular components. Ligand-bound proteins in solution and on the surfaces of cells can be denatured without other proteins in the same samples being affected. Chromophore-assisted laser inactivation can be used to study cell surface phenomena by inactivating the functions of single proteins on living cells, a molecular extension of cellular laser ablation. It has an advantage over genetics and the use of specific inhibitors in that the protein function of a single cell within the organism can be inactivated by focusing the laser beam.
NASA Astrophysics Data System (ADS)
Gulyaev, Yurii V.; Suris, Robert A.; Tager, A. A.; Élenkrig, B. B.
1988-11-01
A theoretical investigation is made of fluctuation-induced excitation of side longitudinal modes in the emission spectra of semiconductor lasers, including those with an external mirror. It is shown that nonlinear refraction of light in the active region of a semiconductor laser may result in a noise redistribution of the radiation between longitudinal resonator modes and can be responsible for the multimode nature of the average emission spectrum. An analysis is made of the influence of selectivity of an external mirror on the stability of cw operation, minimum line width, and mode composition of the emission spectra of semiconductor lasers. The conditions for maximum narrowing of the emission spectrum of a semiconductor laser with an external selective mirror are identified.
Laser Ablation of Dental Calculus Around 400 nm Using a Ti:Sapphire Laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schoenly, J.; Seka, W.; Rechmann, P.
2009-10-19
A Nd:YAG laser-pumped, frequency-doubled Ti:sapphire laser is used for selective ablation of calculus. The laser provides ≤25 mJ at 400 nm (60-ns pulse width, 10-Hz repetition rate). The laser is coupled into an optical multimode fiber coiled around a 4-in.-diam drum to generate a top-hat output intensity profile. With coaxial water cooling, this is ideal for efficient, selective calculus removal. This is in stark contrast with tightly focused Gaussian beams that are energetically inefficient and lead to irreproducible results. Calculus is well ablated at high fluences ≥2 J/cm^2; stalling occurs below this fluence because of photobleaching. Healthy hard tissue ismore » not removed at fluences ≤3 J/cm^2.« less
NASA Astrophysics Data System (ADS)
Yoshida, Tsuyoshi; Saito, Naoaki; Ohmura, Hideki
2018-03-01
Intense (5.0 × 1012 W cm-2) nanosecond Fourier-synthesized laser fields consisting of fundamental, second-, third-, and fourth-harmonic light generated by an interferometer-free Fourier-synthesized laser field generator induce orientation-selective ionization based on directionally asymmetric molecular tunneling ionization (TI). The laser field generator ensures adjustment-free operation, high stability, and high reproducibility. Phase-sensitive, orientation-selective molecular TI provides a simple way to estimate the relative phase differences between the fundamental light and each harmonic by data-fitting analysis. This application of Fourier-synthesized laser fields will facilitate not only lightwave engineering but also the control of matter.
Dosimetry control and monitoring of selective retina therapy using optical coherence tomography
NASA Astrophysics Data System (ADS)
Kaufmann, Daniel; Burri, Christian; Arnold, Patrik; Koch, Volker M.; Meier, Christoph; Považay, Boris; Justiz, Joern
2017-07-01
Selective retina therapy and optical coherence tomography have been combined to monitor laser-tissue interaction in real-time. An ex-vivo study of porcine eyes unveils mechanisms that enable automated and accurate dose-control during laser-therapy.
Selective laser sintering: A qualitative and objective approach
NASA Astrophysics Data System (ADS)
Kumar, Sanjay
2003-10-01
This article presents an overview of selective laser sintering (SLS) work as reported in various journals and proceedings. Selective laser sintering was first done mainly on polymers and nylon to create prototypes for audio-visual help and fit-to-form tests. Gradually it was expanded to include metals and alloys to manufacture functional prototypes and develop rapid tooling. The growth gained momentum with the entry of commercial entities such as DTM Corporation and EOS GmbH Electro Optical Systems. Computational modeling has been used to understand the SLS process, optimize the process parameters, and enhance the efficiency of the sintering machine.
NASA Astrophysics Data System (ADS)
Smelov, V. G.; Sotov, A. V.; Agapovichev, A. V.; Nosova, E. A.
2018-03-01
The structure and mechanical properties of samples are obtained from metal powder based on intermetallic compound by selective laser melting. The chemical analysis of the raw material and static tensile test of specimens were made. Change in the samples’ structure and mechanical properties after homogenization during four and twenty-four hours were investigated. A small-sized combustion chamber of a gas turbine engine was performed by the selective laser melting method. The print combustion chamber was subjected to the gas-dynamic test in a certain temperature and time range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordienko, A V; Mavritskii, O B; Egorov, A N
2014-12-31
The statistics of the ionisation response amplitude measured at selected points and their surroundings within sensitive regions of integrated circuits (ICs) under focused femtosecond laser irradiation is obtained for samples chosen from large batches of two types of ICs. A correlation between these data and the results of full-chip scanning is found for each type. The criteria for express validation of IC single-event effect (SEE) hardness based on ionisation response measurements at selected points are discussed. (laser applications and other topics in quantum electronics)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bajric, Sendin
Additive manufacturing needs a broader selection of materials for part production. In order for the Los Alamos National Laboratory (LANL) to investigate new materials for selective laser sintering (SLS), this paper reviews research on the effect of print parameters on part density, accuracy, and surface roughness of polyamide 12 (PA12, PA2200). The literature review serves to enhance the understanding of how changing the laser powder, scan speed, etc. will affect the mechanical properties of a commercial powder. By doing so, this understanding will help the investigation of new materials for SLS.
Selective laser melting of Inconel super alloy-a review
NASA Astrophysics Data System (ADS)
Karia, M. C.; Popat, M. A.; Sangani, K. B.
2017-07-01
Additive manufacturing is a relatively young technology that uses the principle of layer by layer addition of material in solid, liquid or powder form to develop a component or product. The quality of additive manufactured part is one of the challenges to be addressed. Researchers are continuously working at various levels of additive manufacturing technologies. One of the significant powder bed processes for met als is Selective Laser Melting (SLM). Laser based processes are finding more attention of researchers and industrial world. The potential of this technique is yet to be fully explored. Due to very high strength and creep resistance Inconel is extensively used nickel based super alloy for manufacturing components for aerospace, automobile and nuclear industries. Due to law content of Aluminum and Titanium, it exhibits good fabricability too. Therefore the alloy is ideally suitable for selective laser melting to manufacture intricate components with high strength requirements. The selection of suitable process for manufacturing for a specific component depends on geometrical complexity, production quantity, and cost and required strength. There are numerous researchers working on various aspects like metallurgical and micro structural investigations and mechanical properties, geometrical accuracy, effects of process parameters and its optimization and mathematical modeling etc. The present paper represents a comprehensive overview of selective laser melting process for Inconel group of alloys.
Bae, Jung Min; Jung, Han Mi; Goo, Boncheol; Park, Young Min
2015-07-01
Alopecia is one of the most common dermatological problems in the elderly; however, current therapies for it are limited by low efficacy and undesirable side effects. Although clinical reports on fractional laser treatment for various alopecia types are increasing, the exact mechanism remains to be clarified. The purposes of this study were to demonstrate the effect of ablative fractional laser treatment on hair follicle regrowth in vivo and investigate the molecular mechanism after laser treatment. Ablative CO2 fractional laser was applied to the shaved dorsal skin of 7-week-old C57BL/6 mice whose hair was in the telogen stage. After 12 mice were treated at various energy (10-40 mJ/spot) and density (100-400 spots/cm(2) ) settings to determine the proper dosage for maximal effect. Six mice were then treated at the decided dosage and skin specimens were sequentially obtained by excision biopsy from the dorsal aspect of each mouse. Tissue samples were used for the immunohistochemistry and reverse transcription polymerase chain reaction assays to examine hair follicle status and their related molecules. The most effective dosage was the 10 mJ/spot and 300 spots/cm(2) setting. The anagen conversion of hair was observed in the histopathological examination, while Wnt/β-catenin expression was associated with hair regrowth in the immunohistochemistry and molecular studies. Ablative fractional lasers appear to be effective for inducing hair regrowth via activation of the Wnt/β-catenin pathway in vivo. Our findings indicate that fractional laser treatment can potentially be developed as new treatment options for stimulating hair regrowth. © 2015 Wiley Periodicals, Inc.
Efficacy of Er,Cr:YSGG Laser in Removing Smear Layer and Debris with Two Different Output Powers
Bolhari, Behnam; Ehsani, Sara; Etemadi, Ardavan; Shafaq, Mohammad
2014-01-01
Abstract Objective: The purpose of this study was to evaluate the effectiveness of the erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser in removing debris and the smear layer using two different output powers on the apical, middle, and coronal segments of root canal walls. Background data: Previous literature has failed to evaluate the exclusive effect of Er,Cr:YSGG laser on the quality of smear layer and debris removal in all three segments of the root canal space. Methods: Sixty extracted teeth were included in the study. After instrumentation, samples were divided into three experimental groups and one positive control group with no further treatment. In group 1, a final irrigation was performed using ethylenediaminetetraacetic acid (EDTA) and sodium hypochlorite (NaOCl), sequentially. In group 2, the samples were treated with a 2.78 μm Er,Cr:YSGG laser with an output power of 1.5 W. The same laser was used in group 3, but with an output power of 2.5 W. Scanning electron microscope (SEM) images from the coronal, middle, and apical thirds of the roots were prepared and evaluated for both smear layer and debris removal by three blinded observers. Results: The results showed no differences between groups 1 and 2 regarding the quality of smear layer removal in all areas. However, the 2.5 W laser failed to remove the smear layer effectively. Regarding debris removal, the EDTA and NaOCl irrigation showed significantly better outcomes (adjusted p<0.05) in all areas. Conclusions: This study raises questions about the overall cleaning abilities of Er,Cr:YSGG lasers. PMID:25198390
Efficacy of Er,Cr:YSGG laser in removing smear layer and debris with two different output powers.
Bolhari, Behnam; Ehsani, Sara; Etemadi, Ardavan; Shafaq, Mohammad; Nosrat, Ali
2014-10-01
The purpose of this study was to evaluate the effectiveness of the erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser in removing debris and the smear layer using two different output powers on the apical, middle, and coronal segments of root canal walls. Previous literature has failed to evaluate the exclusive effect of Er,Cr:YSGG laser on the quality of smear layer and debris removal in all three segments of the root canal space. Sixty extracted teeth were included in the study. After instrumentation, samples were divided into three experimental groups and one positive control group with no further treatment. In group 1, a final irrigation was performed using ethylenediaminetetraacetic acid (EDTA) and sodium hypochlorite (NaOCl), sequentially. In group 2, the samples were treated with a 2.78 μm Er,Cr:YSGG laser with an output power of 1.5 W. The same laser was used in group 3, but with an output power of 2.5 W. Scanning electron microscope (SEM) images from the coronal, middle, and apical thirds of the roots were prepared and evaluated for both smear layer and debris removal by three blinded observers. The results showed no differences between groups 1 and 2 regarding the quality of smear layer removal in all areas. However, the 2.5 W laser failed to remove the smear layer effectively. Regarding debris removal, the EDTA and NaOCl irrigation showed significantly better outcomes (adjusted p<0.05) in all areas. This study raises questions about the overall cleaning abilities of Er,Cr:YSGG lasers.
Treatment of actinic cheilitis with the Er:YAG laser.
Armenores, Paul; James, Craig L; Walker, Patrick C; Huilgol, Shyamala C
2010-10-01
Actinic cheilitis is a common condition with the potential to develop into squamous cell carcinoma. Current treatments have varying cure rates and complications. The role of the erbium:yttrium-aluminum-garnet (Er:YAG) laser in the treatment of actinic cheilitis has not been widely published, despite offering theoretical advantages over current treatment modalities. To evaluate the outcome of a series of patients treated with the Er:YAG laser for actinic cheilitis. This was a retrospective, interventional, nonrandomized, sequential case series set in a tertiary referral, dermatologic surgery unit. Ninety-nine consecutive patients with actinic cheilitis treated with the Er:YAG laser between January 2001 and June 2008 underwent a case note review, of which 77 went on to a structured telephone interview. The main outcome measures were a subjective improvement in lip symptoms related to actinic cheilitis and objective improvement in the lips at routine follow-up. Mean time to interview follow-up was 65.7 months. Of those interviewed, 92.2% believed there had been an improvement in the cosmetic appearance of their lips; one hundred percent believed the function of their lips had improved or remained unchanged; and 84.8% remained completely disease free at the time of follow-up. The majority of patients (93.5%) were satisfied with the laser treatment. Scarring as a direct result of the laser occurred in 5.1% of patients. Retrospective nature of data collection; inability to interview all patients who underwent treatment. The Er:YAG laser is a successful modality for the treatment of actinic cheilitis with good functional and cosmetic results and only a small risk of long-term scarring. It should be considered as a first-line treatment for the disease. Copyright © 2009 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
Thermal behavior in single track during selective laser melting of AlSi10Mg powder
NASA Astrophysics Data System (ADS)
Wei, Pei; Wei, Zhengying; Chen, Zhen; He, Yuyang; Du, Jun
2017-09-01
A three-dimensional model was developed to simulate the radiation heat transfer in the AlSi10Mg packed bed. The volume of fluid method (VOF) was used to capture the free surface during selective laser melting (SLM). A randomly packed powder bed was obtained using discrete element method (DEM) in Particle Flow Code (PFC). The proposed model has demonstrated a high potential to simulate the selective laser melting process (SLM) with high accuracy. In this paper, the effect of the laser scanning speed and laser power on the thermodynamic behavior of the molten pool was investigated numerically. The results show that the temperature gradient and the resultant surface tension gradient between the center and the edge of the molten pool increase with decreasing the scanning speed or increasing the laser power, thereby intensifying the Marangoni flow and attendant turbulence within the molten pool. However, at a relatively high scanning speed, a significant instability may be generated in the molten pool. The perturbation and instability in the molten pool during SLM may result in an irregular shaped track.
Exploring Teachers' Read-Aloud Book Selections: What Drives the Decision
ERIC Educational Resources Information Center
Ross, Rachael L.
2017-01-01
Reading aloud is a common classroom practice that has many cognitive and affective benefits for students. Early childhood teachers conduct read-aloud events in classrooms across the country on a daily basis. A read-aloud event could not occur without the intentional selection of a book. This exploratory, sequential mixed method study explored the…
Highlights of laser-tissue interaction mechanism
NASA Astrophysics Data System (ADS)
Gabay, Shimon
2001-10-01
The aim of this paper is to present the fundamentals of good practice when using the laser in medicine and surgery. As a 'good practice' recommendation, the laser beam wavelength and power should be determined to match the desired thermal effect. The energy losses to the surroundings of the initial absorbing volume, caused by the heat diffusion mechanism, are strongly dependent on the exposure time duration. The differences in the absorption and scattering coefficients of some tissue components are used for selectively destroying those components having the higher absorption coefficients. Selective destruction of some tissue components can be achieved even for components having the same absorption coefficient but different dimensions. The laser therapy strategy is discussed: the effective use of lasers in medicine can be achieved only if the physician has an extensive understanding of the laser-tissue interaction mechanisms; continuing education and training is a must for laser surgeons to improve their skill to get clinically optimal results.
Inversion of the resonance line of Sr/+/ produced by optically pumping Sr atoms
NASA Technical Reports Server (NTRS)
Green, W. R.; Falcone, R. W.
1978-01-01
A description is presented of an experiment which demonstrates the selective production of excited-state ions by an optical absorption from neutrals. An inversion on the resonance line of Sr(+) was produced by laser excitation of a two-electron transition, followed by ionization of one of the excited electrons by the same laser. A pulsed, mode-locked laser operating at 2680 A was used to excite atoms from the Sr ground level. The same laser then ionized the excited atoms. The 2680-A pump beam was generated by frequency doubling the output of a synchronously pumped mode-locked dye laser in a KDP crystal. It is pointed out that the reported results are significant for the construction of vacuum-ultraviolet and X-ray lasers. Many of the proposed methods for making such lasers depend on the selective production of excited-state ions.
Interfacial exciplex formation in bilayers of conjugated polymers.
Nobuyasu, R S; Araujo, K A S; Cury, L A; Jarrosson, T; Serein-Spirau, F; Lère-Porte, J-P; Dias, F B; Monkman, A P
2013-10-28
The donor-acceptor interactions in sequential bilayer and blend films are investigated. Steady-state and time-resolved photoluminescence (PL) were measured to characterize the samples at different geometries of photoluminescence collection. At standard excitation, with the laser incidence at 45° of the normal direction of the sample surface, a band related to the aggregate states of donor molecules appears for both blend and bilayer at around 540 nm. For the PL spectra acquired from the edge of the bilayer, with the laser incidence made at normal direction of the sample surface (90° geometry), a new featureless band emission, red-shifted from donor and acceptor emission regions was observed and assigned as the emission from interfacial exciplex states. The conformational complexity coming from donor/acceptor interactions at the heterojunction interface of the bilayer is at the origin of this interfacial exciplex emission.
Lopez, Ramon; Farber, Mark O.; Wong, Vincent; Lacey, Steven E.
2016-01-01
Objective We conducted an exposure chamber study in humans using a simulated clinical procedure lasing porcine tissue to demonstrate evidence of effects of exposure to laser generated particulate matter (LGPM). Methods We measured pre- and post-exposure changes in exhaled nitric oxide (eNO), spirometry, heart rate variability (HRV), and blood markers of inflammation in five volunteers. Results Change in pre- and post-exposure measurements of eNO and spirometry were unremarkable. Neutrophil and lymphocyte counts increased and fibrinogen levels decreased in four of the five subjects. Measures of HRV showed decreases in the standard deviation of normal between beat intervals and sequential five-minute intervals. Conclusion These data represent the first evidence of human physiologic response to LGPM exposure. Further exploration of coagulation effects and HRV are warranted. PMID:27465102
Non-destructive testing of ceramic materials using mid-infrared ultrashort-pulse laser
NASA Astrophysics Data System (ADS)
Sun, S. C.; Qi, Hong; An, X. Y.; Ren, Y. T.; Qiao, Y. B.; Ruan, Liming M.
2018-04-01
The non-destructive testing (NDT) of ceramic materials using mid-infrared ultrashort-pulse laser is investigated in this study. The discrete ordinate method is applied to solve the transient radiative transfer equation in 2D semitransparent medium and the emerging radiative intensity on boundary serves as input for the inverse analysis. The sequential quadratic programming algorithm is employed as the inverse technique to optimize objective function, in which the gradient of objective function with respect to reconstruction parameters is calculated using the adjoint model. Two reticulated porous ceramics including partially stabilized zirconia and oxide-bonded silicon carbide are tested. The retrieval results show that the main characteristics of defects such as optical properties, geometric shapes and positions can be accurately reconstructed by the present model. The proposed technique is effective and robust in NDT of ceramics even with measurement errors.
Van Blarigan, Peter; Haupt, David L.
1982-01-01
A system is provided for welding a workpiece (10, FIG. 1) along a predetermined weld line (12) that may be of irregular shape, which includes the step of forming a lip (32) on the workpiece to extend parallel to the weld line, and moving the workpiece by engaging the lip between a pair of rotatable members (34, 36). Rotation of one of the members at a constant speed, causes the workpiece to move so that all points on the weld line sequentially pass a fixed point in space (17) at a constant speed, so that a laser welding beam can be directed at that fixed point to form a weld along the weld line. The workpiece can include a reuseable jig (24) forming the lip, and with the jig constructed to detachably hold parts (22, 20) to be welded at a position wherein the weld line of the parts extends parallel to the lip on the jig.
He, Feng; Ruiz, Camilo; Becker, Andreas
2007-08-24
We study the control of dissociation of the hydrogen molecular ion and its isotopes exposed to two ultrashort laser pulses by solving the time-dependent Schrödinger equation. While the first ultraviolet pulse is used to excite the electron wave packet on the dissociative 2psigma{u} state, a second time-delayed near-infrared pulse steers the electron between the nuclei. Our results show that by adjusting the time delay between the pulses and the carrier-envelope phase of the near-infrared pulse, a high degree of control over the electron localization on one of the dissociating nuclei can be achieved (in about 85% of all fragmentation events). The results demonstrate that current (sub-)femtosecond technology can provide a control over both electron excitation and localization in the fragmentation of molecules.
Hirose, Makoto; Shimomura, Kei; Suzuki, Akihiro; Burdet, Nicolas; Takahashi, Yukio
2016-05-30
The sample size must be less than the diffraction-limited focal spot size of the incident beam in single-shot coherent X-ray diffraction imaging (CXDI) based on a diffract-before-destruction scheme using X-ray free electron lasers (XFELs). This is currently a major limitation preventing its wider applications. We here propose multiple defocused CXDI, in which isolated objects are sequentially illuminated with a divergent beam larger than the objects and the coherent diffraction pattern of each object is recorded. This method can simultaneously reconstruct both objects and a probe from the coherent X-ray diffraction patterns without any a priori knowledge. We performed a computer simulation of the prposed method and then successfully demonstrated it in a proof-of-principle experiment at SPring-8. The prposed method allows us to not only observe broad samples but also characterize focused XFEL beams.
NASA Astrophysics Data System (ADS)
Sergio, L. P. S.; Trajano, L. A. S. N.; Thomé, A. M. C.; Mencalha, A. L.; Paoli, F.; Fonseca, A. S.
2018-06-01
Acute lung injury (ALI) is a potentially fatal disease characterized by uncontrolled hyperinflammatory responses in the lungs as a consequence of sepsis. ALI is divided into two sequential and time-dependent phases, exudative and fibroproliferative phases, with increased permeability of the alveolar barrier, causing edema and inflammation. However, there are no specific treatments for ALI. Low-power lasers have been successfully used in the resolution of acute inflammatory processes. The aim of this study was to evaluate the effects of low-power infrared laser exposure on alveolus and interalveolar septa of Wistar rats affected by ALI-induced by sepsis. Laser fluences, power, and the emission mode were those used in clinical protocols for the treatment of acute inflammation. Adult male Wistar rats were randomized into six groups: control, 10 J cm‑2, 20 J cm‑2, ALI, ALI + 10 J cm‑2, and ALI + 20 J cm‑2. ALI was induced by intraperitoneal Escherichia coli lipopolysaccharide (LPS). Lungs were removed and processed for hematoxylin–eosin staining. Morphological alterations induced by LPS in lung tissue were quantified by morphometry with a 32-point cyclic arcs test system in Stepanizer. Data showed that exposure to low-power infrared laser in both fluences reduced the thickening of interalveolar septa in lungs affected by ALI, increasing the alveolar space; however, inflammatory infiltrate was still observed. Our research showed that exposure to low-power infrared laser improves the lung parenchyma in Wistar rats affected by ALI, which could be an alternative approach for treatment of inflammatory lung injuries.
NASA Astrophysics Data System (ADS)
Albrodt, P.; Hanna, M.; Moron, F.; Decker, J.; Winterfeldt, M.; Blume, G.; Erbert, G.; Crump, P.; Georges, P.; Lucas-Leclin, G.
2018-02-01
Improved diode laser beam combining techniques are in strong demand for applications in material processing. Coherent beam combining (CBC) is the only combining approach that has the potential to maintain or even improve all laser properties, and thus has high potential for future systems. As part of our ongoing studies into CBC of diode lasers, we present recent progress in the coherent superposition of high-power single-pass tapered laser amplifiers. The amplifiers are seeded by a DFB laser at λ = 976 nm, where the seed is injected into a laterally single-mode ridge-waveguide input section. The phase pistons on each beam are actively controlled by varying the current in the ridge section of each amplifier, using a sequential hill-climbing algorithm, resulting in a combined beam with power fluctuations of below 1%. The currents into the tapered sections of the amplifiers are separately controlled, and remain constant. In contrast to our previous studies, we favour a limited number of individual high-power amplifiers, in order to preserve a high extracted power per emitter in a simple, low-loss coupling arrangement. Specifically, a multi-arm interferometer architecture with only three devices is used, constructed using 6 mm-long tapered amplifiers, mounted junction up on C-mounts, to allow separate contact to single mode and amplifier sections. A maximum coherently combined power of 12.9 W is demonstrated in a nearly diffraction-limited beam, corresponding to a 65% combining efficiency, with power mainly limited by the intrinsic beam quality of the amplifiers. Further increased combined power is currently sought.
Er:YAG laser technology for remote sensing applications
NASA Astrophysics Data System (ADS)
Chen, Moran; Burns, Patrick M.; Litvinovitch, Viatcheslav; Storm, Mark; Sawruk, Nicholas W.
2016-10-01
Fibertek has developed an injection locked, resonantly pumped Er:YAG solid-state laser operating at 1.6 μm capable of pulse repetition rates of 1 kHz to 10 kHz for airborne methane and water differential absorption lidars. The laser is resonantly pumped with a fiber-coupled 1532 nm diode laser minimizing the quantum defect and thermal loading generating tunable single-frequency output of 1645-1646 nm with a linewidth of < 100 MHz. The frequency-doubled 1.6 μm Er:YAG laser emits wavelengths in the 822-823 nm spectrum, coincident with water vapor lines. Various cavity designs were studied and optimized for compactness and performance, with the optimal design being an injection seeded and locked five-mirror ring cavity. The laser generated 4 W of average power at pulse repetition frequencies (PRFs) of 1 kHz and 10 kHz, corresponding to 4 mJ and 400 μJ pulse energies, respectively. The 1645 nm was subsequently frequency doubled to 822.5 nm with a 600 pm tuning range covering multiple water absorption lines, with a pulse energy of 1 mJ and a pulse repetition frequency of 1 kHz. The resonator cavity was locked to the seed wavelength via a Pound Drever Hall (PDH) technique and an analog Proportional Integral Derivative (PID) Controller driving a high-bandwidth piezoelectric (PZT)-mounted cavity mirror. Two seed sources lasing on and off the methane absorption line were optically switched to tune the resonator wavelength on and off the methane absorption line between each sequential output pulse. The cavity locking servo maintained the cavity resonance for each pulse.
Parabolic lithium mirror for a laser-driven hot plasma producing device
Baird, James K.
1979-06-19
A hot plasma producing device is provided, wherein pellets, singly injected, of frozen fuel are each ignited with a plurality of pulsed laser beams. Ignition takes place within a void area in liquid lithium contained within a pressure vessel. The void in the liquid lithium is created by rotating the pressure vessel such that the free liquid surface of molten lithium therein forms a paraboloid of revolution. The paraboloid functions as a laser mirror with a reflectivity greater than 90%. A hot plasma is produced when each of the frozen deuterium-tritium pellets sequentially arrive at the paraboloid focus, at which time each pellet is illuminated by the plurality of pulsed lasers whose rays pass through circular annuli across the top of the paraboloid. The beams from the lasers are respectively directed by associated mirrors, or by means of a single conical mirror in another embodiment, and by the mirror-like paraboloid formed by the rotating liquid lithium onto the fuel pellet such that the optical flux reaching the pellet can be made to be uniform over 96% of the pellet surface area. The very hot plasma produced by the action of the lasers on the respective singly injected fuel pellets in turn produces a copious quantity of neutrons and X-rays such that the device has utility as a neutron source or as an x-ray source. In addition, the neutrons produced in the device may be utilized to produce tritium in a lithium blanket and is thus a mechanism for producing tritium.
Safety approaches for high power modular laser operation
NASA Astrophysics Data System (ADS)
Handren, R. T.
1993-03-01
Approximately 20 years ago, a program was initiated at the Lawrence Livermore National Laboratory (LLNL) to study the feasibility of using lasers to separate isotopes of uranium and other materials. Of particular interest was the development of a uranium enrichment method for the production of commercial nuclear power reactor fuel to replace current more expensive methods. The Uranium Atomic Vapor Laser Isotope Separation (U-AVLIS) Program progressed to the point where a plant-scale facility to demonstrate commercial feasibility was built and is being tested. The U-AVLIS Program uses copper vapor lasers which pump frequency selective dye lasers to photoionize uranium vapor produced by an electron beam. The selectively ionized isotopes are electrostatically collected. The copper lasers are arranged in oscillator/amplifier chains. The current configuration consists of 12 chains, each with a nominal output of 800 W for a system output in excess of 9 kW. The system requirements are for continuous operation (24 h a day, 7 days a week) and high availability. To meet these requirements, the lasers are designed in a modular form allowing for rapid change-out of the lasers requiring maintenance. Since beginning operation in early 1985, the copper lasers have accumulated over 2 million unit hours at a greater than 90% availability. The dye laser system provides approximately 2.5 kW average power in the visible wavelength range. This large-scale laser system has many safety considerations, including high-power laser beams, high voltage, and large quantities (approximately 3000 gal) of ethanol dye solutions. The Laboratory's safety policy requires that safety controls be designed into any process, equipment, or apparatus in the form of engineering controls. Administrative controls further reduce the risk to an acceptable level. Selected examples of engineering and administrative controls currently being used in the U-AVLIS Program are described.
Chan, Kenneth H.; Hirasuna, Krista; Fried, Daniel
2015-01-01
Objective Dental composite restorative materials are color matched to the tooth and are difficult to remove by mechanical means without excessive removal or damage to peripheral enamel and dentin. Lasers are ideally suited for selective ablation to minimize healthy tissue loss when replacing existing restorations, sealants, or removing composite adhesives such as residual composite left after debonding orthodontic brackets. Methods In this study, a carbon dioxide laser operating at 9.3-μm with a pulse duration of 10–20-microsecond and a pulse repetition rate of ~200 Hz was integrated with a galvanometer based scanner and used to selectively remove composite from tooth surfaces. Spectra of the plume emission were acquired after each laser pulse and used to differentiate between the ablation of dental enamel or composite. Microthermocouples were used to monitor the temperature rise in the pulp chamber during composite removal. The composite was placed on tooth buccal and occlusal surfaces and the carbon dioxide laser beam was scanned across the surface to selectively remove the composite without excessive damage to the underlying sound enamel. The residual composite and the damage to the underlying enamel was evaluated using optical microscopy. Results The laser was able to rapidly remove composite from tooth buccal and occlusal surfaces with minimal damage to the underlying sound enamel and without excessive heat accumulation in the tooth. Conclusion This study demonstrated that composite can be selectively removed from tooth surfaces at clinically relevant rates using a CO2 laser operating at 9.3-μm with high pulse repetition rates with minimal heat deposition and damage to the underlying enamel. PMID:21956630
Chan, Kenneth H; Hirasuna, Krista; Fried, Daniel
2011-09-01
Dental composite restorative materials are color matched to the tooth and are difficult to remove by mechanical means without excessive removal or damage to peripheral enamel and dentin. Lasers are ideally suited for selective ablation to minimize healthy tissue loss when replacing existing restorations, sealants, or removing composite adhesives such as residual composite left after debonding orthodontic brackets. In this study, a carbon dioxide laser operating at 9.3-µm with a pulse duration of 10-20-microsecond and a pulse repetition rate of ∼200 Hz was integrated with a galvanometer based scanner and used to selectively remove composite from tooth surfaces. Spectra of the plume emission were acquired after each laser pulse and used to differentiate between the ablation of dental enamel or composite. Microthermocouples were used to monitor the temperature rise in the pulp chamber during composite removal. The composite was placed on tooth buccal and occlusal surfaces and the carbon dioxide laser beam was scanned across the surface to selectively remove the composite without excessive damage to the underlying sound enamel. The residual composite and the damage to the underlying enamel was evaluated using optical microscopy. The laser was able to rapidly remove composite from tooth buccal and occlusal surfaces with minimal damage to the underlying sound enamel and without excessive heat accumulation in the tooth. This study demonstrated that composite can be selectively removed from tooth surfaces at clinically relevant rates using a CO(2) laser operating at 9.3-µm with high pulse repetition rates with minimal heat deposition and damage to the underlying enamel. Copyright © 2011 Wiley-Liss, Inc.
Laser damage resistant nematic liquid crystal cell
NASA Astrophysics Data System (ADS)
Raszewski, Z.; Piecek, W.; Jaroszewicz, L.; Soms, L.; Marczak, J.; Nowinowski-Kruszelnicki, E.; Perkowski, P.; Kedzierski, J.; Miszczyk, E.; Olifierczuk, M.; Morawiak, P.; Mazur, R.
2013-08-01
There exists a problem in diagnostics of a dense plasma (so-called Thomson diagnostics). For this purpose, the plasma is illuminated by series of high energy laser pulses. Such pulses are generated by several independent lasers operating sequentially, and these pulses are to be directed along an exactly the same optical path. In this case, the energy of each separate pulse is as large as 3 J, so it is impossible to generate a burst of such pulses by a single laser. In this situation, several independent lasers have to be used. To form optical path with λ = 1.064 μm and absolute value of the energy of laser pulse through of 3 J, a special refractive index matched twisted Nematic Liquid Crystal Cell (NLCC) of type LCNP2 with switching on time τON smaller than 5 μs might be applied. High laser damage resistance of NLCC and short τON can be fulfilled by preparation of liquid crystal cells with Liquid Crystal Mixture (LCM), well tuned to twisted nematic electro-optical effect, and well tuned all optical interfaces (Air - Antireflection - Quartz Plate - Electrode - Blocking Film - Aligning Layer - LCM - Aligning Layer - Blocking Film - Electrode - Quartz Plate - Antireflection - Air). In such LCNP2 cell, the transmission is higher than 97% at λ = 1.064 μm, as it is presented by Gooch and Tarry [J. Phys. D: Appl. Phys. 8, 1575 (1975)]. The safe laser density energy is about 0.6 J/cm2 for a train of laser pulses (λ = 1.064 μm, pulse duration 10 ns FWHM, pulse repetition rate 100 pps, train duration 10 s), so the area of liquid crystal cell tolerating 3 J through it shall be as large as 5 cm2. Due to the presence of two blocking film layers between electrodes, LCNP2 can be driven by high voltages. Switching on time smaller than τON = 5 μs was obtained under 200 V switching voltage.
Sang, Mee Kyung; Shrestha, Anupama; Kim, Du-Yeon; Park, Kyungseok; Pak, Chun Ho; Kim, Ki Deok
2013-06-01
We previously developed a sequential screening procedure to select antagonistic bacterial strains against Phytophthora capsici in pepper plants. In this study, we used a modified screening procedure to select effective biocontrol strains against P. capsici; we evaluated the effect of selected strains on Phytophthora blight and anthracnose occurrence and fruit yield in pepper plants under field and plastic house conditions from 2007 to 2009. We selected four potential biocontrol strains (Pseudomonas otitidis YJR27, P. putida YJR92, Tsukamurella tyrosinosolvens YJR102, and Novosphingobium capsulatum YJR107) among 239 bacterial strains. In the 3-year field tests, all the selected strains significantly (P < 0.05) reduced Phytophthora blight without influencing rhizosphere microbial populations; they showed similar or better levels of disease suppressions than in metalaxyl treatment in the 2007 and 2009 tests, but not in the 2008 test. In the 2-year plastic house tests, all the selected strains significantly (P < 0.05) reduced anthracnose incidence in at least one of the test years, but their biocontrol activities were variable. In addition, strains YJR27, YJR92, and YJR102, in certain harvests, increased pepper fruit numbers in field tests and red fruit weights in plastic house tests. Taken together, these results indicate that the screening procedure is rapid and reliable for the selection of potential biocontrol strains against P. capsici in pepper plants. In addition, these selected strains exhibited biocontrol activities against anthracnose, and some of the strains showed plant growth-promotion activities on pepper fruit.
Voynov, Parvan P; Tomov, Georgi T; Mateva, Nonka G
2016-01-01
A venous lake (VL) is a vascular lesion with common occurrence in many patients, manifested as a dark blue-to-violet compressible papule, caused by dilation of venules. The main reasons for the treatment of VL are aesthetic. The haemorrhaging episodes or impairment of oral normal functions are also under considerations. Treatment of lip VL includes surgical excision, selective photocoagulation, cryotherapy, sclerotherapy and electrodessication. The high-intensity diode laser is an option. The 980 nm diode laser is selectively absorbed by haemoglobin and selectively destroys blood vessels, minimising injury to the surrounding healthy skin. The purpose of this study was to evaluate the effectiveness of diode laser in the treatment of VL lesions with the accent on the postoperative defects and aesthetic results. 35 patients aged 37 to 71 were included in this study. A 980 nm diode laser was used in noncontact mode, under local anaesthesia in continuous wave (2-3W, for 20-60s). All patients received only one procedure. Healing process was completed within 2 to 4 weeks after treatment with no scarring. None of the typical adverse effects were observed in the process of healing. Selective photocoagulation is an effective method for treatment of VL. Lower morbidity, minimal patient discomfort and satisfactory functional and aesthetic results are favourable for patients. To optimise the results and to reduce the adverse effects, basic knowledge on lasers and laser-tissue interactions is requisite.
Laser Journal (Selected Articles),
1982-09-10
temperature CO2 branch selection laser with a lifetime already exceeding 6500 hours which may be even longer. HIGH POWER LONG LIFE HeCd LASER Qu Shipu...method of plating single crystal gold film in a vacuum with the foreign material extension method. First mica is used as the substrate. Then a special...Hospital) Chen Zhasping Zhou Yiping et al (Eye, Ear, Nose, Throat Hospital, Examination Department, Shanghai Medical School Number 1.) Qu Zhipu et al
Barriobero-Vila, Pere; Gussone, Joachim; Haubrich, Jan; Sandlöbes, Stefanie; Da Silva, Julio Cesar; Cloetens, Peter; Schell, Norbert; Requena, Guillermo
2017-03-07
Selective laser melting is a promising powder-bed-based additive manufacturing technique for titanium alloys: near net-shaped metallic components can be produced with high resource-efficiency and cost savings [...].
On-Site Additive Manufacturing by Selective Laser Melting of Composite Objects
NASA Astrophysics Data System (ADS)
Fateri, M.; Khosravi, M.
2012-06-01
This paper proposes a method for cost reduction of future space missions by manufacturing parts on foreign planets. The suitability of Selective Laser Melting process for on-site production of metallic, ceramic and glass products on mars is examined.
Laser isotope separation by multiple photon absorption
Robinson, C. Paul; Rockwood, Stephen D.; Jensen, Reed J.; Lyman, John L.; Aldridge, III, Jack P.
1987-01-01
Multiple photon absorption from an intense beam of infrared laser light may be used to induce selective chemical reactions in molecular species which result in isotope separation or enrichment. The molecular species must have a sufficient density of vibrational states in its vibrational manifold that, is the presence of sufficiently intense infrared laser light tuned to selectively excite only those molecules containing a particular isotope, multiple photon absorption can occur. By this technique, for example, intense CO.sub.2 laser light may be used to highly enrich .sup.34 S in natural SF.sub.6 and .sup.11 B in natural BCl.sub.3.
Laser isotope separation by multiple photon absorption
Robinson, C. Paul; Rockwood, Stephen D.; Jensen, Reed J.; Lyman, John L.; Aldridge, III, Jack P.
1977-01-01
Multiple photon absorption from an intense beam of infrared laser light may be used to induce selective chemical reactions in molecular species which result in isotope separation or enrichment. The molecular species must have a sufficient density of vibrational states in its vibrational manifold that, in the presence of sufficiently intense infrared laser light tuned to selectively excite only those molecules containing a particular isotope, multiple photon absorption can occur. By this technique, for example, intense CO.sub.2 laser light may be used to highly enrich .sup.34 S in natural SF.sub.6 and .sup.11 B in natural BCl.sub.3.
A wireless sequentially actuated microvalve system
NASA Astrophysics Data System (ADS)
Baek, Seung-Ki; Yoon, Yong-Kyu; Jeon, Hye-Seon; Seo, Soonmin; Park, Jung-Hwan
2013-04-01
A wireless microvalve system was fabricated based on induction heating for flow control in microfluidics by sequential valve opening. In this approach, we used paraffin wax as a flow plug, which can be changed from solid to liquid with adjacent heating elements operated by induction heating. Programmable opening of valves was devised by using different thermal responses of metal discs to a magnetic field. Copper and nickel discs with a diameter of 2.5 mm and various thicknesses (50, 100 and 200 µm) were prepared as heating elements by a laser cutting method, and they were integrated in the microfluidic channel as part of the microvalve. A calorimetric test was used to measure the thermal properties of the discs in terms of kinds of metal and disc thickness. Sequential openings of the microvalves were performed using the difference in the thermal response of 100 µm thick copper disc and 50 µm thick nickel disc for short-interval openings and 200 µm thick copper disc and 100-µm-thick nickel disc for long-interval openings. The thermal effect on fluid samples as a result of induction heating of the discs was studied by investigating lysozyme denaturation. More heat was generated in heating elements made of copper than in those made of nickel, implying differences in the thermal response of heating elements made of copper and nickel. Also, the thickness of the heating elements affected the thermal response in the elements. Valve openings for short intervals of 1-5 s and long intervals of 15-23 s were achieved by using two sets of heating elements. There was no significant change in lysozyme activity by increasing the temperature of the heating discs. This study demonstrates that a wireless sequentially actuated microvalve system can provide programmed valve opening, portability, ease of fabrication and operation, disposability, and low cost.
Laser techniques for spectroscopy of core-excited atomic levels
NASA Technical Reports Server (NTRS)
Harris, S. E.; Young, J. F.; Falcone, R. W.; Rothenberg, J. E.; Willison, J. R.
1982-01-01
We discuss three techniques which allow the use of tunable lasers for high resolution and picosecond time scale spectroscopy of core-excited atomic levels. These are: anti-Stokes absorption spectroscopy, laser induced emission from metastable levels, and laser designation of selected core-excited levels.
Development of a PC interface board for true color control using an Ar Kr white-light laser
NASA Astrophysics Data System (ADS)
Shin, Yongjin; Park, Sohee; Kim, Youngseop; Lee, Jangwoen
2006-06-01
For the optimal laser display, it is crucial to select and control color signals of proper wavelengths in order to construct a wide range of laser display colors. In traditional laser display schemes, color control has been achieved through the mechanical manipulation of red, green, and blue (RGB) laser beam intensities using color filters. To maximize the effect of a laser display and its color contents, it is desirable to generate laser beams with wide selection of wavelengths. We present an innovative laser display control technique, which generates six channel laser wavelengths from a white-light laser using a RF-controlled polychromatic acousto optical modulator (PCAOM). This technique enables us not only to control the intensity of individual channels, but also to achieve true color signals for the laser beam display including RGB, yellow, cyan, and violet (YCV), and other intermediate colors. For the optimal control of the PCAOM and galvano-mirror, we designed and fabricated a PC interface board. Using this PC control, we separated the white-light from an Ar-Kr mixed gas laser into various wavelengths and reconstructed them into different color schemes. Also we demonstrated the effective control and simultaneous display of reconstructed true color laser beams on a flat screen.
Newton, Paul; Chandler, Val; Morris-Thomson, Trish; Sayer, Jane; Burke, Linda
2015-01-01
To map current selection and recruitment processes for newly qualified nurses and to explore the advantages and limitations of current selection and recruitment processes. The need to improve current selection and recruitment practices for newly qualified nurses is highlighted in health policy internationally. A cross-sectional, sequential-explanatory mixed-method design with 4 components: (1) Literature review of selection and recruitment of newly qualified nurses; and (2) Literature review of a public sector professions' selection and recruitment processes; (3) Survey mapping existing selection and recruitment processes for newly qualified nurses; and (4) Qualitative study about recruiters' selection and recruitment processes. Literature searches on the selection and recruitment of newly qualified candidates in teaching and nursing (2005-2013) were conducted. Cross-sectional, mixed-method data were collected from thirty-one (n = 31) individuals in health providers in London who had responsibility for the selection and recruitment of newly qualified nurses using a survey instrument. Of these providers who took part, six (n = 6) purposively selected to be interviewed qualitatively. Issues of supply and demand in the workforce, rather than selection and recruitment tools, predominated in the literature reviews. Examples of tools to measure values, attitudes and skills were found in the nursing literature. The mapping exercise found that providers used many selection and recruitment tools, some providers combined tools to streamline process and assure quality of candidates. Most providers had processes which addressed the issue of quality in the selection and recruitment of newly qualified nurses. The 'assessment centre model', which providers were adopting, allowed for multiple levels of assessment and streamlined recruitment. There is a need to validate the efficacy of the selection tools. © 2014 John Wiley & Sons Ltd.
Devaluation and sequential decisions: linking goal-directed and model-based behavior
Friedel, Eva; Koch, Stefan P.; Wendt, Jean; Heinz, Andreas; Deserno, Lorenz; Schlagenhauf, Florian
2014-01-01
In experimental psychology different experiments have been developed to assess goal–directed as compared to habitual control over instrumental decisions. Similar to animal studies selective devaluation procedures have been used. More recently sequential decision-making tasks have been designed to assess the degree of goal-directed vs. habitual choice behavior in terms of an influential computational theory of model-based compared to model-free behavioral control. As recently suggested, different measurements are thought to reflect the same construct. Yet, there has been no attempt to directly assess the construct validity of these different measurements. In the present study, we used a devaluation paradigm and a sequential decision-making task to address this question of construct validity in a sample of 18 healthy male human participants. Correlational analysis revealed a positive association between model-based choices during sequential decisions and goal-directed behavior after devaluation suggesting a single framework underlying both operationalizations and speaking in favor of construct validity of both measurement approaches. Up to now, this has been merely assumed but never been directly tested in humans. PMID:25136310
Design and comparison of laser windows for high-power lasers
NASA Astrophysics Data System (ADS)
Niu, Yanxiong; Liu, Wenwen; Liu, Haixia; Wang, Caili; Niu, Haisha; Man, Da
2014-11-01
High-power laser systems are getting more and more widely used in industry and military affairs. It is necessary to develop a high-power laser system which can operate over long periods of time without appreciable degradation in performance. When a high-energy laser beam transmits through a laser window, it is possible that the permanent damage is caused to the window because of the energy absorption by window materials. So, when we design a high-power laser system, a suitable laser window material must be selected and the laser damage threshold of the window must be known. In this paper, a thermal analysis model of high-power laser window is established, and the relationship between the laser intensity and the thermal-stress field distribution is studied by deducing the formulas through utilizing the integral-transform method. The influence of window radius, thickness and laser intensity on the temperature and stress field distributions is analyzed. Then, the performance of K9 glass and the fused silica glass is compared, and the laser-induced damage mechanism is analyzed. Finally, the damage thresholds of laser windows are calculated. The results show that compared with K9 glass, the fused silica glass has a higher damage threshold due to its good thermodynamic properties. The presented theoretical analysis and simulation results are helpful for the design and selection of high-power laser windows.
Laser patterning of diamond films
NASA Astrophysics Data System (ADS)
Narayan, J.; Chen, X.
1992-04-01
Selective deposition and fine-scale patterning of hot filament deposited diamond films by the use of pulsed laser irradiation on silicon and copper substrates are reported. The substrates were abraded with diamond and alumina powders before hot-filament chemical vapor deposition. A drastic enhancement in diamond nucleation (using hot-filament chemical vapor deposition) was observed on specimens treated with diamond powder, whereas enhancement on specimens pretreated with alumina powder was relatively insignificant. It is found that the seeding of diamond crystals was substantially reduced by pulsed laser annealing/melting which removes the plastic damage as well as the seed crystals introduced by diamond powder pretreatment. The selective deposition or fine-scale patterning of diamond films was achieved either by a shadow masking or by scanning a focused laser beam to generate desired patterns. The nucleation can also be enhanced by laser deposition of thin films, such as diamond-like carbon and tungsten carbide (WC), and selective deposition and patterning achieved by controlled removal or deposition of the above films.
Zharov, Vladimir P.; Mercer, Kelly E.; Galitovskaya, Elena N.; Smeltzer, Mark S.
2006-01-01
We describe a new method for selective laser killing of bacteria targeted with light-absorbing gold nanoparticles conjugated with specific antibodies. The multifunctional photothermal (PT) microscope/spectrometer provides a real-time assessment of this new therapeutic intervention. In this integrated system, strong laser-induced overheating effects accompanied by the bubble-formation phenomena around clustered gold nanoparticles are the main cause of bacterial damage. PT imaging and time-resolved monitoring of the integrated PT responses assessed these effects. Specifically, we used this technology for selective killing of the Gram-positive bacterium Staphylococcus aureus by targeting the bacterial surface using 10-, 20-, and 40-nm gold particles conjugated with anti-protein A antibodies. Labeled bacteria were irradiated with focused laser pulses (420–570 nm, 12 ns, 0.1–5 J/cm2, 100 pulses), and laser-induced bacterial damage observed at different laser fluences and nanoparticle sizes was verified by optical transmission, electron microscopy, and conventional viability testing. PMID:16239330
Sequential divergence and the multiplicative origin of community diversity
Hood, Glen R.; Forbes, Andrew A.; Powell, Thomas H. Q.; Egan, Scott P.; Hamerlinck, Gabriela; Smith, James J.; Feder, Jeffrey L.
2015-01-01
Phenotypic and genetic variation in one species can influence the composition of interacting organisms within communities and across ecosystems. As a result, the divergence of one species may not be an isolated process, as the origin of one taxon could create new niche opportunities for other species to exploit, leading to the genesis of many new taxa in a process termed “sequential divergence.” Here, we test for such a multiplicative effect of sequential divergence in a community of host-specific parasitoid wasps, Diachasma alloeum, Utetes canaliculatus, and Diachasmimorpha mellea (Hymenoptera: Braconidae), that attack Rhagoletis pomonella fruit flies (Diptera: Tephritidae). Flies in the R. pomonella species complex radiated by sympatrically shifting and ecologically adapting to new host plants, the most recent example being the apple-infesting host race of R. pomonella formed via a host plant shift from hawthorn-infesting flies within the last 160 y. Using population genetics, field-based behavioral observations, host fruit odor discrimination assays, and analyses of life history timing, we show that the same host-related ecological selection pressures that differentially adapt and reproductively isolate Rhagoletis to their respective host plants (host-associated differences in the timing of adult eclosion, host fruit odor preference and avoidance behaviors, and mating site fidelity) cascade through the ecosystem and induce host-associated genetic divergence for each of the three members of the parasitoid community. Thus, divergent selection at lower trophic levels can potentially multiplicatively and rapidly amplify biodiversity at higher levels on an ecological time scale, which may sequentially contribute to the rich diversity of life. PMID:26499247
NASA Astrophysics Data System (ADS)
Chan, Kenneth H.; Fried, Nathaniel M.; Fried, Daniel
2018-02-01
Previous studies have shown that reflectance imaging at wavelengths greater than 1200-nm can be used to image demineralization on tooth occlusal surfaces with high contrast and without the interference of stains. In addition, these near-IR imaging systems can be integrated with laser ablation systems for the selective removal of carious lesions. Higher wavelengths, such as 1950-nm, yield higher lesion contrast due to higher water absorption and lower scattering. In this study, a point-to-point scanning system employing diode and fiber lasers operating at 1450, 1860, 1880, and 1950-nm was used to acquire reflected light images of the tooth surface. Artificial lesions were imaged at these wavelengths to determine the highest lesion contrast. Near-IR images at 1880-nm were used to demarcate lesion areas for subsequent selective carious lesion removal using a new compact air-cooled CO2 laser prototype operating at 9.3-μm. The highest lesion contrast was at 1950-nm and the dual NIR/CO2 laser system selectively removed the simulated lesions with a mean loss of only 12-μm of sound enamel.
Development and recovery of laser-induced retinal injury in rats
NASA Astrophysics Data System (ADS)
Belokopytov, Mark; Dubinsky, Galina; Belkin, Michael; Epstein, Yoram; Rosner, Mordechai
2005-04-01
Retinal photocoagulation lesions undergo primary and secondary degeneration followed by partial healing. This study follows the sequential changes in laser-induced retinal lesion over a time span of 60 days. Argon laser lesions were created in 36 pigmented rats. Sections of the retinal lesions were evaluated by light microscopy 1, 24, 48, 72 hours, and 20, and 60 days after the injury (six animals at each time point). The diameter of the lesion was equal to that of the laser spot 1h after irradiation and increased by 24h. It decreased later, slightly during the following 48h and significantly by 20 days. The destruction of photoreceptors was most severe after 24-48h. The nuclei in the outer-nuclear layer were pyknotic at the lesion site at 1h and disappeared later. Healing processes began 72h after the irradiation and was completed by 60 days. Filling-in by sliding of near nuclei was observed by the 60th day. Reversible changes were seen also in the retinal pigment epithelium (with formation of a plaque at 72h and its degradation later on) and in the choroid (disorganization of capillaries by 48h with later reorganization). Conclusions: The development of a laser-induced injury is gradual. The photoreceptors are damaged first and than the damage spreads to other layers of retina and to areas adjacent the primary injury site. The extension of the damage is later stopped and the adjacent tissues tend to fill the lesion and remodel the retina.
Laser-activated remote phosphor light engine for projection applications
NASA Astrophysics Data System (ADS)
Daniels, Martin; Mehl, Oliver; Hartwig, Ulrich
2015-09-01
Recent developments in blue emitting laser diodes enable attractive solutions in projection applications using phosphors for efficient light conversion with very high luminance levels. Various commercially available projectors incorporating this technology have entered the market in the past years. While luminous flux levels are still comparable to lamp-based systems, lifetime expectations of classical lamp systems are exceeded by far. OSRAM GmbH has been exploring this technology for several years and has introduced the PHASER® brand name (Phosphor + laser). State-of-the-art is a rotating phosphor wheel excited by blue laser diodes to deliver the necessary primary colors, either sequentially for single-imager projection engines, or simultaneously for 3-panel systems. The PHASER® technology enables flux and luminance scaling, which allows for smaller imagers and therefore cost-efficient projection solutions. The resulting overall efficiency and ANSI lumen specification at the projection screen of these systems is significantly determined by the target color gamut and the light transmission efficiency of the projection system. With increasing power and flux level demand, thermal issues, especially phosphor conversion related, dominate the opto-mechanical system design requirements. These flux levels are a great challenge for all components of an SSL-projection system (SSL:solid-state lighting). OSRAḾs PHASER® light engine platform is constantly expanded towards higher luminous flux levels as well as higher luminance levels for various applications. Recent experiments employ blue laser pump powers of multiple 100 Watts to excite various phosphors resulting in luminous flux levels of more than 40 klm.
Design of voice coil motor dynamic focusing unit for a laser scanner
NASA Astrophysics Data System (ADS)
Lee, Moon G.; Kim, Gaeun; Lee, Chan-Woo; Lee, Soo-Hun; Jeon, Yongho
2014-04-01
Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden-Fletcher-Goldfarb-Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.
Design of voice coil motor dynamic focusing unit for a laser scanner.
Lee, Moon G; Kim, Gaeun; Lee, Chan-Woo; Lee, Soo-Hun; Jeon, Yongho
2014-04-01
Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden-Fletcher-Goldfarb-Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.
Park, Jong-Myeon; Cho, Yoon-Kyoung; Lee, Beom-Seok; Lee, Jeong-Gun; Ko, Christopher
2007-05-01
Valving is critical in microfluidic systems. Among many innovative microvalves used in lab-on-a-chip applications, phase change based microvalves using paraffin wax are particularly attractive for disposable biochip applications because they are simple to implement, cost-effective and biocompatible. However, previously reported paraffin-based valves require embedded microheaters and therefore multi-step operation of many microvalves was a difficult problem. Besides, the operation time was relatively long, 2-10 s. In this paper, we report a unique phase change based microvalve for rapid and versatile operation of multiple microvalves using a single laser diode. The valve is made of nanocomposite materials in which 10 nm-sized iron oxide nanoparticles are dispersed in paraffin wax and used as nanoheaters when excited by laser irradiation. Laser light of relatively weak intensity was able to melt the paraffin wax with the embedded iron oxide nanoparticles, whereas even a very intense laser beam does not melt wax alone. The microvalves are leak-free up to 403.0 +/- 7.6 kPa and the response times to operate both normally closed and normally opened microvalves are less than 0.5 s. Furthermore, a sequential operation of multiple microvalves on a centrifugal microfluidic device using a single laser diode was demonstrated. It showed that the optical control of multiple microvalves is fast, robust, simple to operate, and requires minimal chip space and thus is well suited for fully integrated lab-on-a-chip applications.
Changing profile of excimer laser coronary angioplasty: refinements in catheters
NASA Astrophysics Data System (ADS)
Bittl, John A.
1994-07-01
During more than five years of investigation with excimer laser angioplasty, several changes have been made in patient selection and laser catheters. It is unclear, however, whether these changes have improved the outcome of excimer laser angioplasty. A total of 2041 patients underwent treatment with excimer laser coronary angioplasty for 2324 lesions with clinical success in 89%, ischemic complications in 7.5%, and vessel perforation in 2.1%. When the entire 5-year period of investigation was divided into four discrete phases, as defined by the successive release of improved laser catheters (prototype, flexible, extremely flexible, and eccentric), clinical success was seen to improve from 86% to 95% (p<0.001) despite the increased incidence of advanced age (pequals0.01) and unstable angina (p<0.001). Multivariable analysis identified improved laser catheters, saphenous vein graft lesions, and unclarified stenoses as predictors of favorable outcome. Operator experience was associated with decreased complications. Reduced catheter size relative to vessel size was associated with decreased risk of vessel perforation. Thus, refinements in patient selection and in laser technique have been associated with enhanced safety and efficacy of excimer laser angioplasty.
NASA Astrophysics Data System (ADS)
Nikolić, Vlastimir; Petković, Dalibor; Lazov, Lyubomir; Milovančević, Miloš
2016-07-01
Water-jet assisted underwater laser cutting has shown some advantages as it produces much less turbulence, gas bubble and aerosols, resulting in a more gentle process. However, this process has relatively low efficiency due to different losses in water. It is important to determine which parameters are the most important for the process. In this investigation was analyzed the water-jet assisted underwater laser cutting parameters forecasting based on the different parameters. The method of ANFIS (adaptive neuro fuzzy inference system) was applied to the data in order to select the most influential factors for water-jet assisted underwater laser cutting parameters forecasting. Three inputs are considered: laser power, cutting speed and water-jet speed. The ANFIS process for variable selection was also implemented in order to detect the predominant factors affecting the forecasting of the water-jet assisted underwater laser cutting parameters. According to the results the combination of laser power cutting speed forms the most influential combination foe the prediction of water-jet assisted underwater laser cutting parameters. The best prediction was observed for the bottom kerf-width (R2 = 0.9653). The worst prediction was observed for dross area per unit length (R2 = 0.6804). According to the results, a greater improvement in estimation accuracy can be achieved by removing the unnecessary parameter.
Selective removal of composite sealants with near-UV laser pulses
NASA Astrophysics Data System (ADS)
Louie, Tiffany M.; Jones, Robert S.; Sarma, Anupama V.; Fried, Daniel
2004-05-01
It is often necessary to replace pit and fissure sealants and composite restorations. This task is complicated by the necessity for complete removal of the remaining composite to enable suitable adhesion of new composite. Previous studies have shown that lasers pulses from a frequency-tripled Nd:YAG laser (355-nm) can selectively remove residual composite after orthodontic bracket removal on enamel surfaces. UV laser light is preferentially absorbed by polymeric resins and the organic content of the tooth enamel. The objective of this study was to determine if such laser pulses are suitable for selective removal of the old composite from pit and fissure sealants and restorations without damaging surrounding sound tissues. Optical coherence tomography was used to acquire optical cross sections of the occlusal topography and peripheral tooth structure non-destructively before application of the sealants, after sealant application, and after sealant removal with 355-nm laser pulses with intensities ranging from 0-10 J/cm2. Thermocouples were used to monitor the temperature in the pulp chamber during composite removal under clinically relevant ablation rates, i.e., 30 Hz and 30 mJ per laser pulse. At an irradiation intensity of 1.3 J/cm2 pit and fissure sealants were completely removed without visible damage to the underlying enamel. At intensities above 1.5 J/cm2, the laser removes the resin layer while at the same time preferentially etching the surface of the enamel. Temperature excursions in the pulp chamber of extracted teeth was limited to less than 5°C if air-cooling was used during the rapid removal (1-2 min) of sealants, water-cooling was not needed. This is the first presentation of a method for the selective removal of composite restorative materials without damage to the underlying sound tooth structure.
Evaluation of 4 Different Irrigating Systems for Apical Extrusion of Sodium Hypochlorite.
Yost, Ross A; Bergeron, Brian E; Kirkpatrick, Timothy C; Roberts, Mark D; Roberts, Howard W; Himel, Van T; Sabey, Kent A
2015-09-01
The aim of this study was to evaluate NaOCl apical extrusion by using negative apical pressure (EndoVac), sonic agitation (EndoActivator), side-vented needle (Max-i-Probe), and photon induced photoacoustic streaming (PIPS 10 mJ and PIPS 20 mJ) laser irrigation in an in vitro gel model. Extracted mandibular and maxillary central incisors (n = 18) were prepared to size 35/.04 and 55/.04, respectively. Teeth were mounted in transparent containers with clear acrylic and suspended in a color-changing pH-sensitive gel, creating a closed system. By using a crossover design, each tooth was sequentially irrigated by using 6% NaOCl with each device following manufacturers' recommendations. Each tooth served as its own control. Pre-irrigation and post-irrigation buccal and proximal view photographs served to measure the longest distance of extrusion and were analyzed with ImageJ software. Mean results were analyzed by using Kruskal-Wallis and Dunn post hoc test (P < .05). There were no significant differences between EndoVac, EndoActivator, and the passive extrusion groups. The EndoVac and EndoActivator groups produced significantly less extrusion than PIPS irrigation. Max-i-Probe extrusion results were more variable than those of EndoActivator but had no significant difference. Across all irrigation systems, there were no significant differences with respect to apical preparation size. Under the in vitro conditions of this study, no difference was found between the 10 mJ and 20 mJ PIPS laser groups. EndoVac demonstrated significantly less potential for apical extrusion than PIPS and Max-i-Probe, whereas apical preparation size did not significantly affect extrusion of irrigant. The potential for apical extrusion of endodontic irrigants should be a consideration when selecting a system for final irrigation. Published by Elsevier Inc.
Vortex shedding in bileaflet heart valve prostheses.
Gross, J M; Shermer, C D; Hwang, N H
1988-01-01
A dynamic study of two geometrically similar bileaflet heart valve prostheses (HVP) was performed using a physiologic mock circulatory flow loop. The HVPs studied were the 25 mm St. Jude Medical (SJM) and the 25 mm Carbomedics (CMI) in the aortic position and the 27 mm SJM and 27 mm CMI in the mitral position. All data were collected at a heart rate of 70 beats/min and a cardiac output of 5.0 L/min. Flow visualization was conducted in the transparent flow chambers of the pulsatile mock circulatory flow loop using a 15 mW He-Ne laser light source. A cylindrical lens and optics system converted the incident laser beam into a thin parallel light plane, and 420 microns tracer particles were suspended in the testing fluid to illuminate the flow field at selected planes. Frame-by-frame analysis of the 16 mm high-speed cine provides detailed phasic flow patterns in the vicinity of the HVP. A series of still photographs of flow patterns, taken at approximately 22.5 degrees phase intervals, are sequentially presented for each HVP. In the aortic position, a Karman-like vortex pattern appears downstream of the SJM at the end of the ejection phase. The CMI exhibits a rather symmetrical ejection flow pattern that turns into random motion immediately after the onset of ejection. In the mitral position, the SJM again exhibits a strong core flow during ventricular filling, whereas the CMI produces a more diffuse pattern during the same period. A pair of vortices shed from both the SJM and CMI are clearly visible toward the end of the ventricular filling phase. The vortex mechanisms are discussed in light of leaflet boundary layer formation.
NASA Astrophysics Data System (ADS)
Ishii, K.; Tsukimoto, H.; Hazama, H.; Awazu, K.
2008-02-01
Laser angioplasty, for example XeCl excimer laser angioplasty, has gained more attention in addition to conventional methods of surgical and interventional treatment of atherosclerotic diseases such as bypass operation and balloon dilatation. Low degrees of thermal damage after ablation of atherosclerotic lesions have been achieved by XeCl excimer laser at 308 nm. However, in most cases, laser ablation is not selective and normal arterial wall is also damaged. To avoid complications such as severe dissections or perforation of the arterial wall in an angioplasty, a laser light source with high ablation efficiency but low arterial wall injury is desirable. At atherosclerotic lesions, cholesterol accumulates on the tunica intima by establishing an ester bond with fatty acids such as oleic acid, and thus cholesterol ester is the main component of atherosclerotic plaques. Mid-infrared pulsed laser at 5.75 μm is selectively well absorbed in C=O stretching vibration mode of ester bonds. The purpose of this study is to determine the effectiveness of nanosecond pulsed laser at 5.75 μm irradiation of cholesterol ester in atherosclerotic plaques. In this study, we used a mid-infrared tunable solid-state laser which is operated by difference frequency generation method, with a wavelength of 5.75 μm, a pulse width of 5 nsec and a pulse duration of 10 Hz. It was confirmed that non-invasive interaction to normal thoracic aortas could be induce by the parameters, the wavelength of 5.75 μm, the average power densities of 35 W/cm2 and the irradiation time under 10 sec. This study shows that nanosecond pulsed laser irradiations at 5.75 μm provide an alternative laser light source as an effectively cutting, less traumatic tool for removal of atherosclerotic plaque.
2018-01-01
To date, a few studies have investigated the potential use of a short-pulsed laser in selective tumor cell destruction or its mechanism of cell killing. Computer simulation of the spatial and temporal profiles of temperature elevation after pulsed laser irradiation on an infinitesimal point source estimated that the temperature reached its highest point at ∼35 ns after a single 15 ns laser pulse. Moreover, temperature elevation was confined to a radius of sub-micrometer and returned to baseline within 100 ns. To investigate the effect of 15 ns laser pulses on A431 tumor cells, we conjugated hollow gold nanospheres (HAuNSs) to an antibody (C225) directed at the epithelial growth factor receptor. The resulting nanoparticles, C225-HAuNSs, bound to the cell membrane, internalized, and distributed throughout the cytoplasm, with some nanoparticles transported to the vicinity of the nuclear membrane. On using an optical microscope mounted to a tunable pulsed Ti:sapphire laser, rapid and extensive damage of live cancer cells was observed, whereas irradiation of A431 cells pretreated with nontargeted HAuNSs with a pulsed laser or pretreated with C225-HAuNSs with a continuous-wave laser-induced minimal cellular damage. Furthermore, after a single 15 ns laser pulse, C225-HAuNS-treated A431 cells cocultured with 3T3 fibroblasts showed signs of selective destruction. Thus, compared with a continuous-wave laser, shots of a short-pulsed laser were the most damaging to tumor cells that bound HAuNSs and generated the least heat to the surrounding environment. This mode of action by a short-pulsed laser on cancer cells (i.e., confined photothermolysis) may have potential applications in selective tumor cell destruction. PMID:29876540
Ku, Geng; Huang, Qian; Wen, Xiaoxia; Ye, John; Piwnica-Worms, David; Li, Chun
2018-05-31
To date, a few studies have investigated the potential use of a short-pulsed laser in selective tumor cell destruction or its mechanism of cell killing. Computer simulation of the spatial and temporal profiles of temperature elevation after pulsed laser irradiation on an infinitesimal point source estimated that the temperature reached its highest point at ∼35 ns after a single 15 ns laser pulse. Moreover, temperature elevation was confined to a radius of sub-micrometer and returned to baseline within 100 ns. To investigate the effect of 15 ns laser pulses on A431 tumor cells, we conjugated hollow gold nanospheres (HAuNSs) to an antibody (C225) directed at the epithelial growth factor receptor. The resulting nanoparticles, C225-HAuNSs, bound to the cell membrane, internalized, and distributed throughout the cytoplasm, with some nanoparticles transported to the vicinity of the nuclear membrane. On using an optical microscope mounted to a tunable pulsed Ti:sapphire laser, rapid and extensive damage of live cancer cells was observed, whereas irradiation of A431 cells pretreated with nontargeted HAuNSs with a pulsed laser or pretreated with C225-HAuNSs with a continuous-wave laser-induced minimal cellular damage. Furthermore, after a single 15 ns laser pulse, C225-HAuNS-treated A431 cells cocultured with 3T3 fibroblasts showed signs of selective destruction. Thus, compared with a continuous-wave laser, shots of a short-pulsed laser were the most damaging to tumor cells that bound HAuNSs and generated the least heat to the surrounding environment. This mode of action by a short-pulsed laser on cancer cells (i.e., confined photothermolysis) may have potential applications in selective tumor cell destruction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapp, S., E-mail: rapp@hm.edu; Erlangen Graduate School in Advanced Optical Technologies; Heinrich, G.
2015-03-14
In the production process of silicon microelectronic devices and high efficiency silicon solar cells, local contact openings in thin dielectric layers are required. Instead of photolithography, these openings can be selectively structured with ultra-short laser pulses by confined laser ablation in a fast and efficient lift off production step. Thereby, the ultrafast laser pulse is transmitted by the dielectric layer and absorbed at the substrate surface leading to a selective layer removal in the nanosecond time domain. Thermal damage in the substrate due to absorption is an unwanted side effect. The aim of this work is to obtain a deepermore » understanding of the physical laser-material interaction with the goal of finding a damage-free ablation mechanism. For this, thin silicon nitride (SiN{sub x}) layers on planar silicon (Si) wafers are processed with infrared fs-laser pulses. Two ablation types can be distinguished: The known confined ablation at fluences below 300 mJ/cm{sup 2} and a combined partial confined and partial direct ablation at higher fluences. The partial direct ablation process is caused by nonlinear absorption in the SiN{sub x} layer in the center of the applied Gaussian shaped laser pulses. Pump-probe investigations of the central area show ultra-fast reflectivity changes typical for direct laser ablation. Transmission electron microscopy results demonstrate that the Si surface under the remaining SiN{sub x} island is not damaged by the laser ablation process. At optimized process parameters, the method of direct laser ablation could be a good candidate for damage-free selective structuring of dielectric layers on absorbing substrates.« less
Review of selective laser melting: Materials and applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yap, C. Y., E-mail: cyap001@e.ntu.edu.sg; Energy Research Institute @ NTU, Interdisciplinary Graduate School, Nanyang Technological University, 50 Nanyang Avenue, Block S2 - B3a - 01, Singapore 639798; Chua, C. K., E-mail: mckchua@ntu.edu.sg
Selective Laser Melting (SLM) is a particular rapid prototyping, 3D printing, or Additive Manufacturing (AM) technique designed to use high power-density laser to melt and fuse metallic powders. A component is built by selectively melting and fusing powders within and between layers. The SLM technique is also commonly known as direct selective laser sintering, LaserCusing, and direct metal laser sintering, and this technique has been proven to produce near net-shape parts up to 99.9% relative density. This enables the process to build near full density functional parts and has viable economic benefits. Recent developments of fibre optics and high-power lasermore » have also enabled SLM to process different metallic materials, such as copper, aluminium, and tungsten. Similarly, this has also opened up research opportunities in SLM of ceramic and composite materials. The review presents the SLM process and some of the common physical phenomena associated with this AM technology. It then focuses on the following areas: (a) applications of SLM materials and (b) mechanical properties of SLM parts achieved in research publications. The review is not meant to put a ceiling on the capabilities of the SLM process but to enable readers to have an overview on the material properties achieved by the SLM process so far. Trends in research of SLM are also elaborated in the last section.« less
Prediction of microstructure, residual stress, and deformation in laser powder bed fusion process
NASA Astrophysics Data System (ADS)
Yang, Y. P.; Jamshidinia, M.; Boulware, P.; Kelly, S. M.
2018-05-01
Laser powder bed fusion (L-PBF) process has been investigated significantly to build production parts with a complex shape. Modeling tools, which can be used in a part level, are essential to allow engineers to fine tune the shape design and process parameters for additive manufacturing. This study focuses on developing modeling methods to predict microstructure, hardness, residual stress, and deformation in large L-PBF built parts. A transient sequentially coupled thermal and metallurgical analysis method was developed to predict microstructure and hardness on L-PBF built high-strength, low-alloy steel parts. A moving heat-source model was used in this analysis to accurately predict the temperature history. A kinetics based model which was developed to predict microstructure in the heat-affected zone of a welded joint was extended to predict the microstructure and hardness in an L-PBF build by inputting the predicted temperature history. The tempering effect resulting from the following built layers on the current-layer microstructural phases were modeled, which is the key to predict the final hardness correctly. It was also found that the top layers of a build part have higher hardness because of the lack of the tempering effect. A sequentially coupled thermal and mechanical analysis method was developed to predict residual stress and deformation for an L-PBF build part. It was found that a line-heating model is not suitable for analyzing a large L-PBF built part. The layer heating method is a potential method for analyzing a large L-PBF built part. The experiment was conducted to validate the model predictions.
Cataract surgery practices in the United States Veterans Health Administration.
Havnaer, Annika G; Greenberg, Paul B; Cockerham, Glenn C; Clark, Melissa A; Chomsky, Amy
2017-04-01
To describe current cataract surgery practices within the United States Veterans Health Administration (VHA). Veterans Health Administration hospitals in the U.S. Retrospective data analysis. An initial e-mail containing a link to an anonymous 32-question survey of cataract surgery practices was sent to participants in May 2016. Two reminder e-mails were sent to nonresponders 1 week and 2 weeks after the initial survey was sent; the remaining nonresponders were called twice over a 2-week period. The data were analyzed using descriptive statistics. The response rate was 75% (67/89). Cataract surgeons routinely ordered preoperative testing in 29 (45%) of 65 sections and preoperative consultations in 26 (39%) of 66 sections. In 22 (33%) of 66 sections, cataract surgeons administered intracameral antibiotics. In 61 (92%) of 66 sections, cataract surgeons used toric intraocular lenses (IOLs). In 20 (30%) of 66 sections, cataract surgeons used multifocal IOLs. Cataract surgeons in 6 (9%) of 66 sections performed femtosecond laser-assisted cataract surgery. In 6 (9%) of 66 sections, cataract surgeons performed immediate sequential bilateral cataract surgery. Forty-nine (74%) ophthalmology chiefs reported a high level of satisfaction with Veterans Affairs ophthalmology. The survey results indicate that in cataract surgery in the VHA, routine preoperative testing is commonly performed and emerging practices, such as femtosecond laser-assisted cataract surgery and immediate sequential bilateral cataract surgery, have limited roles. The results of this survey could benchmark future trends in U.S. cataract surgery practices, especially in teaching hospital settings. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Prediction of microstructure, residual stress, and deformation in laser powder bed fusion process
NASA Astrophysics Data System (ADS)
Yang, Y. P.; Jamshidinia, M.; Boulware, P.; Kelly, S. M.
2017-12-01
Laser powder bed fusion (L-PBF) process has been investigated significantly to build production parts with a complex shape. Modeling tools, which can be used in a part level, are essential to allow engineers to fine tune the shape design and process parameters for additive manufacturing. This study focuses on developing modeling methods to predict microstructure, hardness, residual stress, and deformation in large L-PBF built parts. A transient sequentially coupled thermal and metallurgical analysis method was developed to predict microstructure and hardness on L-PBF built high-strength, low-alloy steel parts. A moving heat-source model was used in this analysis to accurately predict the temperature history. A kinetics based model which was developed to predict microstructure in the heat-affected zone of a welded joint was extended to predict the microstructure and hardness in an L-PBF build by inputting the predicted temperature history. The tempering effect resulting from the following built layers on the current-layer microstructural phases were modeled, which is the key to predict the final hardness correctly. It was also found that the top layers of a build part have higher hardness because of the lack of the tempering effect. A sequentially coupled thermal and mechanical analysis method was developed to predict residual stress and deformation for an L-PBF build part. It was found that a line-heating model is not suitable for analyzing a large L-PBF built part. The layer heating method is a potential method for analyzing a large L-PBF built part. The experiment was conducted to validate the model predictions.
One-step shaping of NiTi biomaterial by selective laser melting
NASA Astrophysics Data System (ADS)
Yang, Yongqiang; Huang, Yanlu; Wu, Wenhui
2007-11-01
NiTi alloy has excellent biocompatibility. This paper presents a novel technology of direct shaping of this promising biomaterial with selective laser melting (SLM). The frequently encountered defects of the SLM metal alloy parts such as non-fully melting, thermal deformation and balling were analyzed theoretically and experimentally, and the microstructure of the parts was analyzed on microscope. The results show that an appropriate selection of laser mode and scanning strategy assures a satisfying quality of the final parts; they also reveal that the SLM technology can be expected as a potential technology to directly manufacture the artificial implant of NiTi alloys.
NASA Technical Reports Server (NTRS)
Flamant, P. H.; Menzies, R. T.; Kavaya, M. J.; Oppenheim, U. P.
1983-01-01
A grating-tunable TEA-CO2 laser with an unstable resonator cavity, modified to allow injection of CW CO2 laser radiation at the resonant transition line by means of an intracavity NaCl window, has been used to study the coupling requirements for generation of single frequency pulses. The width and shape of the mode selection region, and the dependence of the gain-switched spike buildup time and the pulse shapes on the intensity and detuning frequency of the injected radiation are reported. Comparisons of the experimental results with previously reported mode selection behavior are discussed.
Laser vaporization of trace explosives for enhanced non-contact detection
NASA Astrophysics Data System (ADS)
Furstenberg, Robert; Papantonakis, Michael; Kendziora, Christopher A.; Bubb, Daniel M.; Corgan, Jeffrey; McGill, R. Andrew
2010-04-01
Trace explosives contamination is found primarily in the form of solid particulates on surfaces, due to the low vapor pressure of most explosives materials. Today, the standard sampling procedure involves physical removal of particulate matter from surfaces of interest. A variety of collection methods have been used including air-jetting or swabbing surfaces of interest. The sampled particles are typically heated to generate vapor for analysis in hand held, bench top, or portal detection systems. These sampling methods are time-consuming (and hence costly), require a skilled technician for optimal performance, and are inherently non-selective, allowing non-explosives particles to be co-sampled and analyzed. This can adversely affect the sensitivity and selectivity of detectors, especially those with a limited dynamic range. We present a new approach to sampling solid particles on a solid surface that is targeted, non-contact, and which selectively enhances trace explosive signatures thus improving the selectivity and sensitivity of existing detectors. Our method involves the illumination of a surface of interest with infrared laser light with a wavelength that matches a distinctive vibrational mode of an explosive. The resonant coupling of laser energy results in rapid heating of explosive particles and rapid release of a vapor plume. Neighboring particles unrelated to explosives are generally not directly heated as their vibrational modes are not resonant with the laser. As a result, the generated vapor plume includes a higher concentration of explosives than if the particles were heated with a non-selective light source (e.g. heat lamp). We present results with both benchtop infrared lasers as well as miniature quantum cascade lasers.
NASA Astrophysics Data System (ADS)
Xiong, Gang; Li, Shuiqing; Tse, Stephen D.
2018-02-01
In recent years, a novel low-intensity phase-selective laser-induced breakdown spectroscopy (PS-LIBS) technique has been developed for unique elemental-composition identification of aerosolized nanoparticles, where only the solid-phase nanoparticles break down, forming nanoplasmas, without any surrounding gas-phase breakdown. Additional work has demonstrated that PS-LIBS emissions can be greatly enhanced with secondary resonant excitation by matching the excitation laser wavelength with an atomic transition line in the formed nanoplasma, thereby achieving low limits of detection. In this work, a tunable dye laser is employed to investigate the effects of excitation wavelength and irradiance on in-situ PS-LIBS measurements of TiO2 nanoaerosols. The enhancement factor by resonant excitation can be 220 times greater than that for non-resonant cases under similar conditions. Moreover, the emitted spectra are unique for the selected resonant transition lines for a given element, suggesting the potential to make precise phase-selective and analyte-selective measurements of nanoparticles in a multicomponent multiphase system. The enhancement factor by resonant excitation is highly sensitive to excitation laser wavelength, with narrow excitation spectral windows, i.e., 0.012 to 0.023 nm (FWHM, full width at half maximum) for Ti (I) neutral atomic lines, and 0.051 to 0.139 nm (FWHM) for Ti (II) single-ionized atomic lines. Boltzmann analysis of the emission intensities, temporal response of emissions, and emission dependence on excitation irradiance are investigated to understand aspects of the generated nanoplasmas such as temperature, local thermodynamic equilibrium (LTE), and excitation mechanism.
Tunable, rare earth-doped solid state lasers
Emmett, John L.; Jacobs, Ralph R.; Krupke, William F.; Weber, Marvin J.
1980-01-01
Laser apparatus comprising combinations of an excimer pump laser and a rare earth-doped solid matrix, utilizing the 5d-4f radiative transition in a rare earth ion to produce visible and ultra-violet laser radiation with high overall efficiency in selected cases and relatively long radiative lifetimes.
Oh, Kwang Seok; Woo, Seong Ihl
2011-01-01
A chemiluminescence-based analyzer of NOx gas species has been applied for high-throughput screening of a library of catalytic materials. The applicability of the commercial NOx analyzer as a rapid screening tool was evaluated using selective catalytic reduction of NO gas. A library of 60 binary alloys composed of Pt and Co, Zr, La, Ce, Fe or W on Al2O3 substrate was tested for the efficiency of NOx removal using a home-built 64-channel parallel and sequential tubular reactor. The NOx concentrations measured by the NOx analyzer agreed well with the results obtained using micro gas chromatography for a reference catalyst consisting of 1 wt% Pt on γ-Al2O3. Most alloys showed high efficiency at 275 °C, which is typical of Pt-based catalysts for selective catalytic reduction of NO. The screening with NOx analyzer allowed to select Pt-Ce(X) (X=1–3) and Pt–Fe(2) as the optimal catalysts for NOx removal: 73% NOx conversion was achieved with the Pt–Fe(2) alloy, which was much better than the results for the reference catalyst and the other library alloys. This study demonstrates a sequential high-throughput method of practical evaluation of catalysts for the selective reduction of NO. PMID:27877438
Lagator, Mato; Colegrave, Nick; Neve, Paul
2014-11-07
In rapidly changing environments, selection history may impact the dynamics of adaptation. Mutations selected in one environment may result in pleiotropic fitness trade-offs in subsequent novel environments, slowing the rates of adaptation. Epistatic interactions between mutations selected in sequential stressful environments may slow or accelerate subsequent rates of adaptation, depending on the nature of that interaction. We explored the dynamics of adaptation during sequential exposure to herbicides with different modes of action in Chlamydomonas reinhardtii. Evolution of resistance to two of the herbicides was largely independent of selection history. For carbetamide, previous adaptation to other herbicide modes of action positively impacted the likelihood of adaptation to this herbicide. Furthermore, while adaptation to all individual herbicides was associated with pleiotropic fitness costs in stress-free environments, we observed that accumulation of resistance mechanisms was accompanied by a reduction in overall fitness costs. We suggest that antagonistic epistasis may be a driving mechanism that enables populations to more readily adapt in novel environments. These findings highlight the potential for sequences of xenobiotics to facilitate the rapid evolution of multiple-drug and -pesticide resistance, as well as the potential for epistatic interactions between adaptive mutations to facilitate evolutionary rescue in rapidly changing environments. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Nanodiamond in Colloidal Suspension: Electrophoresis; Other Observations
NASA Technical Reports Server (NTRS)
Meshik, A. P.; Pravdivtseva, O. V.; Hohenberg, C. M.
2002-01-01
Selective laser extraction has demonstrated that meteoritic diamonds may consist of subpopulations with different optical absorption properties, but it is not clear what makes them optically different. More work is needed to understand the mechanism for selective laser extraction. Additional information is contained in the original extended abstract.
Bis-reaction-trigger as a strategy to improve the selectivity of fluorescent probes.
Li, Dan; Cheng, Juan; Wang, Cheng-Kun; Ying, Huazhou; Hu, Yongzhou; Han, Feng; Li, Xin
2018-06-01
By the strategy of equipping a fluorophore with two reaction triggers that are tailored to the specific chemistry of peroxynitrite, we have developed a highly selective probe for detecting peroxynitrite in live cells. Sequential response by the two triggers enabled the probe to reveal various degrees of nitrosative stress in live cells via a sensitive emission colour change.
Saxena, Saurabh; Stanek, Jan; Cevec, Mirko; Plavec, Janez; Koźmiński, Wiktor
2014-11-01
A through bond, C4'/H4' selective, "out and stay" type 4D HC(P)CH experiment is introduced which provides sequential connectivity via H4'(i)-C4'(i)-C4'(i-1)-H4'(i-1) correlations. The (31)P dimension (used in the conventional 3D HCP experiment) is replaced with evolution of better dispersed C4' dimension. The experiment fully utilizes (13)C-labeling of RNA by inclusion of two C4' evolution periods. An additional evolution of H4' is included to further enhance peak resolution. Band selective (13)C inversion pulses are used to achieve selectivity and prevent signal dephasing due to the of C4'-C3' and C4'-C5' homonuclear couplings. For reasonable resolution, non-uniform sampling is employed in all indirect dimensions. To reduce sensitivity losses, multiple quantum coherences are preserved during shared-time evolution and coherence transfer delays. In the experiment the intra-nucleotide peaks are suppressed whereas inter-nucleotide peaks are enhanced to reduce the ambiguities. The performance of the experiment is verified on a fully (13)C, (15)N-labeled 34-nt hairpin RNA comprising typical structure elements.
Dantus, Marcos; Lozovoy, Vadim V
2014-01-21
A laser system is provided which selectively excites Raman active vibrations in molecules. In another aspect of the present invention, the system includes a laser, pulse shaper and detection device. A further aspect of the present invention employs a femtosecond laser and binary pulse shaping (BPS). Still another aspect of the present invention uses a laser beam pulse, a pulse shaper and remote sensing.
Barriobero-Vila, Pere; Gussone, Joachim; Haubrich, Jan; Sandlöbes, Stefanie; Da Silva, Julio Cesar; Cloetens, Peter; Schell, Norbert; Requena, Guillermo
2017-01-01
Selective laser melting is a promising powder-bed-based additive manufacturing technique for titanium alloys: near net-shaped metallic components can be produced with high resource-efficiency and cost savings. For the most commercialized titanium alloy, namely Ti-6Al-4V, the complicated thermal profile of selective laser melting manufacturing (sharp cycles of steep heating and cooling rates) usually hinders manufacturing of components in a one-step process owing to the formation of brittle martensitic microstructures unsuitable for structural applications. In this work, an intensified intrinsic heat treatment is applied during selective laser melting of Ti-6Al-4V powder using a scanning strategy that combines porosity-optimized processing with a very tight hatch distance. Extensive martensite decomposition providing a uniform, fine lamellar α + β microstructure is obtained along the building direction. Moreover, structural evidence of the formation of the intermetallic α2-Ti3Al phase is provided. Variations in the lattice parameter of β serve as an indicator of the microstructural degree of stabilization. Interconnected 3D networks of β are generated in regions highly affected by the intensified intrinsic heat treatment applied. The results obtained reflect a contribution towards simultaneous selective laser melting-manufacturing and heat treatment for fabrication of Ti-6Al-4V parts. PMID:28772630
Near-infrared image-guided laser ablation of artificial caries lesions.
Tao, You-Chen; Fan, Kenneth; Fried, Daniel
2007-01-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. The objective of this study was to test the hypothesis that two-dimensional NIR images of demineralized tooth surfaces can be used to guide CO(2) laser ablation for the selective removal of artificial caries lesions. Highly patterned artificial lesions were produced by submerging 5 × 5 mm(2) bovine enamel samples in demineralized solution for a 9-day period while sound areas were protected with acid resistant varnish. NIR imaging and polarization sensitive optical coherence tomography (PS-OCT) were used to acquire depth-resolved images at a wavelength of 1310-nm. An imaging processing module was developed to analyze the NIR images and to generate optical maps. The optical maps were used to control a CO(2) laser for the selective removal of the lesions at a uniform depth. This experiment showed that the patterned artificial lesions were removed selectively using the optical maps with minimal damage to sound enamel areas. Post-ablation NIR and PS-OCT imaging confirmed that demineralized areas were removed while sound enamel was conserved. This study successfully demonstrated that near-IR imaging can be integrated with a CO(2) laser ablation system for the selective removal of dental caries.
Near-infrared image-guided laser ablation of artificial caries lesions
Tao, You-Chen; Fan, Kenneth; Fried, Daniel
2012-01-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. The objective of this study was to test the hypothesis that two–dimensional NIR images of demineralized tooth surfaces can be used to guide CO2 laser ablation for the selective removal of artificial caries lesions. Highly patterned artificial lesions were produced by submerging 5 × 5 mm2 bovine enamel samples in demineralized solution for a 9-day period while sound areas were protected with acid resistant varnish. NIR imaging and polarization sensitive optical coherence tomography (PS-OCT) were used to acquire depth-resolved images at a wavelength of 1310-nm. An imaging processing module was developed to analyze the NIR images and to generate optical maps. The optical maps were used to control a CO2 laser for the selective removal of the lesions at a uniform depth. This experiment showed that the patterned artificial lesions were removed selectively using the optical maps with minimal damage to sound enamel areas. Post-ablation NIR and PS-OCT imaging confirmed that demineralized areas were removed while sound enamel was conserved. This study successfully demonstrated that near-IR imaging can be integrated with a CO2 laser ablation system for the selective removal of dental caries. PMID:22866210
Near-infrared image-guided laser ablation of artificial caries lesions
NASA Astrophysics Data System (ADS)
Tao, You-Chen; Fan, Kenneth; Fried, Daniel
2007-02-01
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. The objective of this study was to test the hypothesis that two-dimensional NIR images of demineralized tooth surfaces can be used to guide CO II laser ablation for the selective removal of artificial caries lesions. Highly patterned artificial lesions were produced by submerging 5 x 5 mm2 bovine enamel samples in demineralized solution for a 9-day period while sound areas were protected with acid resistant varnish. NIR imaging and polarization sensitive optical coherence tomography (PS-OCT) were used to acquire depth-resolved images at a wavelength of 1310-nm. An imaging processing module was developed to analyze the NIR images and to generate optical maps. The optical maps were used to control a CO II laser for the selective removal of the lesions at a uniform depth. This experiment showed that the patterned artificial lesions were removed selectively using the optical maps with minimal damage to sound enamel areas. Post-ablation NIR and PS-OCT imaging confirmed that demineralized areas were removed while sound enamel was conserved. This study successfully demonstrated that near-IR imaging can be integrated with a CO II laser ablation system for the selective removal of dental caries.
Laser isotope separation by multiple photon absorption
Robinson, C.P.; Rockwood, S.D.; Jensen, R.J.; Lyman, J.L.; Aldridge, J.P. III.
1987-04-07
Multiple photon absorption from an intense beam of infrared laser light may be used to induce selective chemical reactions in molecular species which result in isotope separation or enrichment. The molecular species must have a sufficient density of vibrational states in its vibrational manifold that, is the presence of sufficiently intense infrared laser light tuned to selectively excite only those molecules containing a particular isotope, multiple photon absorption can occur. By this technique, for example, intense CO[sub 2] laser light may be used to highly enrich [sup 34]S in natural SF[sub 6] and [sup 11]B in natural BCl[sub 3]. 8 figs.
In-Flight Thermal Performance of the Geoscience Laser Altimeter System (GLAS) Instrument
NASA Technical Reports Server (NTRS)
Grob, Eric; Baker, Charles; McCarthy, Tom
2003-01-01
The Geoscience Laser Altimeter System (GLAS) instrument is NASA Goddard Space Flight Center's first application of Loop Heat Pipe technology that provides selectable/stable temperature levels for the lasers and other electronics over a widely varying mission environment. GLAS was successfully launched as the sole science instrument aboard the Ice, Clouds, and Land Elevation Satellite (ICESat) from Vandenberg AFB at 4:45pm PST on January 12, 2003. After SC commissioning, the LHPs started easily and have provided selectable and stable temperatures for the lasers and other electronics. This paper discusses the thermal development background and testing, along with details of early flight thermal performance data.
Jelger, P; Wang, P; Sahu, J K; Laurell, F; Clarkson, W A
2008-06-23
In this work a volume Bragg grating is used as a wavelength selective element in a high-power cladding-pumped Yb-doped silica fiber laser. The laser produced 138 W of linearly-polarized single-spatial-mode output at 1066 nm with a relatively narrow linewidth of 0.2 nm for approximately 202 W of launched pump power at 976 nm. The beam propagation factor (M(2)) for the output beam was determined to be 1.07. Thermal limitations of volume Bragg gratings are discussed in the context of power scaling for fiber lasers.
NASA Astrophysics Data System (ADS)
Wu, Yongxiao; Wang, Zhongyang; Chen, Sanbin; Shirakwa, Akira; Ueda, Ken-ichi; Li, Jianlang
2018-05-01
We proposed an efficient and vortex Nd:YAG laser for selective lasing of low- and high-order vortex modes, in which multiple-ring pump light was originated from cascaded conical refraction of multiple biaxial crystals. In our proof of concept demonstration, we used two-crystal cascade conical refraction to generate two-ring pump light; the mutual intensity ratio and relative separation of the inner ring and outer ring were controlled by rotating the second biaxial crystal and by moving the imaging lens, respectively. As a result, we obtained selective excitation of Laguerre–Gaussian (LG01 and LG03) vortex modes in the end-pump Nd:YAG laser. For LG01-mode output, the laser power reached 439 mW with 52.5% slope efficiency; for LG03-mode output, the laser power reached 160 mW with 41.3% slope efficiency. Our results revealed that the multiple-ring pumping technique based on cascaded conical refraction would pave the way for realization of the efficient and switchable excitation of low- and high-order LG modes in an end-pumped solid-state laser.
Multi-Wavelength Laser Transmitter for the Two-Step Laser Time-of-Flight Mass Spectrometer
NASA Technical Reports Server (NTRS)
Yu, Anthony W.; Li, Steven X.; Fahey, Molly E.; Grubisic, Andrej; Farcy, Benjamin J.; Uckert, Kyle; Li, Xiang; Getty, Stephanie
2017-01-01
Missions to diverse Outer Solar System bodies will require investigations that can detect a wide range of organics in complex mixtures, determine the structure of selected molecules, and provide powerful insights into their origin and evolution. Previous studies from remote spectroscopy of the Outer Solar System showed a diverse population of macromolecular species that are likely to include aromatic and conjugated hydrocarbons with varying degrees of methylation and nitrile incorporation. In situ exploration of Titan's upper atmosphere via mass and plasma spectrometry has revealed a complex mixture of organics. Similar material is expected on the Ice Giants, their moons, and other Outer Solar System bodies, where it may subsequently be deposited onto surface ices. It is evident that the detection of organics on other planetary surfaces provides insight into the chemical and geological evolution of a Solar System body of interest and can inform our understanding of its potential habitability. We have developed a prototype two-step laser desorption/ionization time-of-flight mass spectrometer (L2MS) instrument by exploiting the resonance-enhanced desorption of analyte. We have successfully demonstrated the ability of the L2MS to detect hydrocarbons in organically-doped analog minerals, including cryogenic Ocean World-relevant ices and mixtures. The L2MS instrument operates by generating a neutral plume of desorbed analyte with an IR desorption laser pulse, followed at a delay by a ultraviolet (UV) laser pulse, ionizing the plume. Desorption of the analyte, including trace organic species, may be enhanced by selecting the wavelength of the IR desorption laser to coincide with IR absorption features associated with vibration transitions of minerals or organic functional groups. In this effort, a preliminary laser developed for the instrument uses a breadboard mid-infrared (MIR) desorption laser operating at a discrete 3.475 µm wavelength, and a breadboard UV ionization laser operating at a wavelength of 266 nm. The MIR wavelength was selected to overlap the C-H stretch vibrational transition of certain aromatic hydrocarbons, and the UV wavelength provides additional selectivity to aromatic species via UV resonance-enhanced multiphoton ionization effects. The use of distinct laser wavelengths allows efficient coupling to the vibrational and electronic spectra of the analyte in independent desorption and ionization steps, mitigating excess energy that can lead to fragmentation during the ionization process and leading to selectivity that can aid in data interpretation.
Optimal flexible sample size design with robust power.
Zhang, Lanju; Cui, Lu; Yang, Bo
2016-08-30
It is well recognized that sample size determination is challenging because of the uncertainty on the treatment effect size. Several remedies are available in the literature. Group sequential designs start with a sample size based on a conservative (smaller) effect size and allow early stop at interim looks. Sample size re-estimation designs start with a sample size based on an optimistic (larger) effect size and allow sample size increase if the observed effect size is smaller than planned. Different opinions favoring one type over the other exist. We propose an optimal approach using an appropriate optimality criterion to select the best design among all the candidate designs. Our results show that (1) for the same type of designs, for example, group sequential designs, there is room for significant improvement through our optimization approach; (2) optimal promising zone designs appear to have no advantages over optimal group sequential designs; and (3) optimal designs with sample size re-estimation deliver the best adaptive performance. We conclude that to deal with the challenge of sample size determination due to effect size uncertainty, an optimal approach can help to select the best design that provides most robust power across the effect size range of interest. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Tsen, K. T.; Tsen, Shaw-Wei D.; Sankey, Otto F.; Kiang, Juliann G.
2007-11-01
We demonstrate an unconventional and revolutionary method for selective inactivation of micro-organisms by using near-infrared femtosecond laser pulses. We show that if the wavelength and pulse width of the excitation femtosecond laser are appropriately selected, there exists a window in power density that enables us to achieve selective inactivation of target viruses and bacteria without causing cytotoxicity in mammalian cells. This strategy targets the mechanical (vibrational) properties of micro-organisms, and thus its antimicrobial efficacy is likely unaffected by genetic mutation in the micro-organisms. Such a method may be effective against a wide variety of drug resistant micro-organisms and has broad implications in disinfection as well as in the development of novel treatments for viral and bacterial pathogens.
Konda Gokuldoss, Prashanth; Kolla, Sri; Eckert, Jürgen
2017-01-01
Additive manufacturing (AM), also known as 3D printing or rapid prototyping, is gaining increasing attention due to its ability to produce parts with added functionality and increased complexities in geometrical design, on top of the fact that it is theoretically possible to produce any shape without limitations. However, most of the research on additive manufacturing techniques are focused on the development of materials/process parameters/products design with different additive manufacturing processes such as selective laser melting, electron beam melting, or binder jetting. However, we do not have any guidelines that discuss the selection of the most suitable additive manufacturing process, depending on the material to be processed, the complexity of the parts to be produced, or the design considerations. Considering the very fact that no reports deal with this process selection, the present manuscript aims to discuss the different selection criteria that are to be considered, in order to select the best AM process (binder jetting/selective laser melting/electron beam melting) for fabricating a specific component with a defined set of material properties. PMID:28773031
Gokuldoss, Prashanth Konda; Kolla, Sri; Eckert, Jürgen
2017-06-19
Additive manufacturing (AM), also known as 3D printing or rapid prototyping, is gaining increasing attention due to its ability to produce parts with added functionality and increased complexities in geometrical design, on top of the fact that it is theoretically possible to produce any shape without limitations. However, most of the research on additive manufacturing techniques are focused on the development of materials/process parameters/products design with different additive manufacturing processes such as selective laser melting, electron beam melting, or binder jetting. However, we do not have any guidelines that discuss the selection of the most suitable additive manufacturing process, depending on the material to be processed, the complexity of the parts to be produced, or the design considerations. Considering the very fact that no reports deal with this process selection, the present manuscript aims to discuss the different selection criteria that are to be considered, in order to select the best AM process (binder jetting/selective laser melting/electron beam melting) for fabricating a specific component with a defined set of material properties.
Matrix-assisted laser desorption/ionization (MALDI) was performed on individual,
size-selected aerosol particles in the 2-8 mu m diameter range, Monodisperse aerosol droplets
containing matrix, analyte, and solvent were generated and entrained in a dry stream of air, The dr...
Time-Delayed Two-Step Selective Laser Photodamage of Dye-Biomolecule Complexes
NASA Astrophysics Data System (ADS)
Andreoni, A.; Cubeddu, R.; de Silvestri, S.; Laporta, P.; Svelto, O.
1980-08-01
A scheme is proposed for laser-selective photodamage of biological molecules, based on time-delayed two-step photoionization of a dye molecule bound to the biomolecule. The validity of the scheme is experimentally demonstrated in the case of the dye Proflavine, bound to synthetic polynucleotides.
Ion laser isotope enrichment by photo-predissociation of formaldehyde
Marling, John B.
1977-06-17
Enrichment of carbon, hydrogen and/or oxygen isotopes by means of isotopically selective photo-predissociation of formaldehyde is achieved by irradiation with a fixed frequency ion laser, specifically, a neon, cadmium, or xenon ion laser.
An overview of clinical and experimental treatment modalities for port wine stains
Chen, Jennifer K.; Ghasri, Pedram; Aguilar, Guillermo; van Drooge, Anne Margreet; Wolkerstorfer, Albert; Kelly, Kristen M.; Heger, Michal
2014-01-01
Port wine stains (PWS) are the most common vascular malformation of the skin, occurring in 0.3% to 0.5% of the population. Noninvasive laser irradiation with flashlamp-pumped pulsed dye lasers (selective photothermolysis) currently comprises the gold standard treatment of PWS; however, the majority of PWS fail to clear completely after selective photothermolysis. In this review, the clinically used PWS treatment modalities (pulsed dye lasers, alexandrite lasers, neodymium:yttrium-aluminum-garnet lasers, and intense pulsed light) and techniques (combination approaches, multiple passes, and epidermal cooling) are discussed. Retrospective analysis of clinical studies published between 1990 and 2011 was performed to determine therapeutic efficacies for each clinically used modality/technique. In addition, factors that have resulted in the high degree of therapeutic recalcitrance are identified, and emerging experimental treatment strategies are addressed, including the use of photodynamic therapy, immunomodulators, angiogenesis inhibitors, hypobaric pressure, and site-specific pharmaco-laser therapy. PMID:22305042
Effects of pulsed CO2 laser in caries selective ablation
NASA Astrophysics Data System (ADS)
Colojoara, Carmen; David, Ion; Marinovici, Mariana
1995-03-01
We have evaluated the effect of pulsed carbon dioxide laser in the treatment for deep carious decay. The so called `caries profonda' is still a problem for conservative dentistry. A `Valvfivre' Master 20S carbon dioxide laser was pulsed to determine the effects on dentine and for testing the properties of softened dentine in selective ablation. Laser treatment parameters were from 1 to 2 W, 50 to 150 ms, 200 to 320 Hz. Fifteen human teeth samples were exposed to irradiation: extracted third molar were exposed to CO2 pulsed laser to determine in vitro the effects on pulp morphology. The tissue samples were analyzed histologically and by means of scanning electron microscopy for evidence of thermal damage. Next, we have evaluated the morphologic changes in vivo on 10 cases in patients with deep carious decay. Pulsed infrared lasers are capable of inducing physical and chemical changes in dentine structure. The results showed an artificially sclerosing and micro-hardness on the remaining dentine. CO2 laser can vaporized carious dentine.
Liu, Huawei; Li, Baoqing; Yuan, Xiaobing; Zhou, Qianwei; Huang, Jingchang
2018-03-27
Parameters estimation of sequential movement events of vehicles is facing the challenges of noise interferences and the demands of portable implementation. In this paper, we propose a robust direction-of-arrival (DOA) estimation method for the sequential movement events of vehicles based on a small Micro-Electro-Mechanical System (MEMS) microphone array system. Inspired by the incoherent signal-subspace method (ISM), the method that is proposed in this work employs multiple sub-bands, which are selected from the wideband signals with high magnitude-squared coherence to track moving vehicles in the presence of wind noise. The field test results demonstrate that the proposed method has a better performance in emulating the DOA of a moving vehicle even in the case of severe wind interference than the narrowband multiple signal classification (MUSIC) method, the sub-band DOA estimation method, and the classical two-sided correlation transformation (TCT) method.
Learning multiple variable-speed sequences in striatum via cortical tutoring.
Murray, James M; Escola, G Sean
2017-05-08
Sparse, sequential patterns of neural activity have been observed in numerous brain areas during timekeeping and motor sequence tasks. Inspired by such observations, we construct a model of the striatum, an all-inhibitory circuit where sequential activity patterns are prominent, addressing the following key challenges: (i) obtaining control over temporal rescaling of the sequence speed, with the ability to generalize to new speeds; (ii) facilitating flexible expression of distinct sequences via selective activation, concatenation, and recycling of specific subsequences; and (iii) enabling the biologically plausible learning of sequences, consistent with the decoupling of learning and execution suggested by lesion studies showing that cortical circuits are necessary for learning, but that subcortical circuits are sufficient to drive learned behaviors. The same mechanisms that we describe can also be applied to circuits with both excitatory and inhibitory populations, and hence may underlie general features of sequential neural activity pattern generation in the brain.
Peng, Shu; Pan, Yu‐Chen; Wang, Yaling; Xu, Zhe; Chen, Chao
2017-01-01
Abstract The introduction of controlled self‐assembly into living organisms opens up desired biomedical applications in wide areas including bioimaging/assays, drug delivery, and tissue engineering. Besides the enzyme‐activated examples reported before, controlled self‐assembly under integrated stimuli, especially in the form of sequential input, is unprecedented and ultimately challenging. This study reports a programmable self‐assembling strategy in living cells under sequentially integrated control of both endogenous and exogenous stimuli. Fluorescent polymerized vesicles are constructed by using cholinesterase conversion followed by photopolymerization and thermochromism. Furthermore, as a proof‐of‐principle application, the cell apoptosis involved in the overexpression of cholinesterase in virtue of the generated fluorescence is monitored, showing potential in screening apoptosis‐inducing drugs. The approach exhibits multiple advantages for bioimaging in living cells, including specificity to cholinesterase, red emission, wash free, high signal‐to‐noise ratio. PMID:29201625
Peng, Shu; Pan, Yu-Chen; Wang, Yaling; Xu, Zhe; Chen, Chao; Ding, Dan; Wang, Yongjian; Guo, Dong-Sheng
2017-11-01
The introduction of controlled self-assembly into living organisms opens up desired biomedical applications in wide areas including bioimaging/assays, drug delivery, and tissue engineering. Besides the enzyme-activated examples reported before, controlled self-assembly under integrated stimuli, especially in the form of sequential input, is unprecedented and ultimately challenging. This study reports a programmable self-assembling strategy in living cells under sequentially integrated control of both endogenous and exogenous stimuli. Fluorescent polymerized vesicles are constructed by using cholinesterase conversion followed by photopolymerization and thermochromism. Furthermore, as a proof-of-principle application, the cell apoptosis involved in the overexpression of cholinesterase in virtue of the generated fluorescence is monitored, showing potential in screening apoptosis-inducing drugs. The approach exhibits multiple advantages for bioimaging in living cells, including specificity to cholinesterase, red emission, wash free, high signal-to-noise ratio.
Mirza, Bilal; Lin, Zhiping
2016-08-01
In this paper, a meta-cognitive online sequential extreme learning machine (MOS-ELM) is proposed for class imbalance and concept drift learning. In MOS-ELM, meta-cognition is used to self-regulate the learning by selecting suitable learning strategies for class imbalance and concept drift problems. MOS-ELM is the first sequential learning method to alleviate the imbalance problem for both binary class and multi-class data streams with concept drift. In MOS-ELM, a new adaptive window approach is proposed for concept drift learning. A single output update equation is also proposed which unifies various application specific OS-ELM methods. The performance of MOS-ELM is evaluated under different conditions and compared with methods each specific to some of the conditions. On most of the datasets in comparison, MOS-ELM outperforms the competing methods. Copyright © 2016 Elsevier Ltd. All rights reserved.
Galvanometer scanning technology for laser additive manufacturing
NASA Astrophysics Data System (ADS)
Luo, Xi; Li, Jin; Lucas, Mark
2017-02-01
A galvanometer laser beam scanning system is an essential element in many laser additive manufacturing (LAM) technologies including Stereolithography (SLA), Selective Laser Sintering (SLS) and Selective Laser Melting (SLM). Understanding the laser beam scanning techniques and recent innovations in this field will greatly benefit the 3D laser printing system integration and technology advance. One of the challenges to achieve high quality 3D printed parts is due to the non-uniform laser power density delivered on the materials caused by the acceleration and deceleration movements of the galvanometer at ends of the hatching and outlining patterns. One way to solve this problem is to modulate the laser power as the function of the scanning speed during the acceleration or deceleration periods. Another strategy is to maintain the constant scanning speed while accurately coordinating the laser on and off operation throughout the job. In this paper, we demonstrate the high speed, high accuracy and low drift digital scanning technology that incorporates both techniques to achieve uniform laser density with minimal additional process development. With the constant scanning speed method, the scanner not only delivers high quality and uniform results, but also a throughput increase of 23% on a typical LAM job, compared to that of the conventional control method that requires galvanometer acceleration and deceleration movements.
Additive Manufacturing of Shape Memory Alloys
NASA Astrophysics Data System (ADS)
Van Humbeeck, Jan
2018-04-01
Selective Laser Melting (SLM) is an additive manufacturing production process, also called 3D printing, in which functional, complex parts are produced by selectively melting patterns in consecutive layers of powder with a laser beam. The pattern the laser beam is following is controlled by software that calculates the pattern by slicing a 3D CAD model of the part to be constructed. Apart from SLM, also other additive manufacturing techniques such as EBM (Electron Beam Melting), FDM (Fused Deposition Modelling), WAAM (Wire Arc Additive Manufacturing), LENS (Laser Engineered Net Shaping such as Laser Cladding) and binder jetting allow to construct complete parts layer upon layer. But since more experience of AM of shape memory alloys is collected by SLM, this paper will overview the potentials, limits and problems of producing NiTi parts by SLM.
NASA Astrophysics Data System (ADS)
Galiová, M.; Kaiser, J.; Novotný, K.; Novotný, J.; Vaculovič, T.; Liška, M.; Malina, R.; Stejskal, K.; Adam, V.; Kizek, R.
2008-12-01
Single-pulse Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass-Spectrometry (LA-ICP-MS) were applied for mapping the silver and copper distribution in Helianthus Annuus L. samples treated with contaminant in controlled conditions. For Ag and Cu detection the 328.07 nm Ag(I) and 324.75 nm Cu(I) lines were used, respectively. The LIBS experimental conditions (mainly the laser energy and the observation window) were optimized in order to avoid self-absorption effect in the measured spectra. In the LA-ICP-MS analysis the Ag 107 and Cu 63 isotopes were detected. The capability of these two analytical techniques for high-resolution mapping of selected trace chemical elements was demonstrated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gertjerenken, B.; Kevrekidis, P. G.; Carretero-González, R.
Here, we numerically investigate an experimentally viable method for generating and manipulating on-demand several vortices in a highly oblate atomic Bose-Einstein condensate (BEC) in order to initialize complex vortex distributions for studies of vortex dynamics. The method utilizes moving laser beams to generate, capture, and transport vortices inside and outside the BEC. This methodology is examined in detail and shows a wide parameter range of applicability for the prototypical two-vortex case, as well as case examples of producing and manipulating several vortices for which there is no net circulation, corresponding to equal numbers of positive and negative circulation vortices, andmore » cases for which there is one net quantum of circulation. We also find that the presence of dissipation can help stabilize the pinning of the vortices on their respective laser beam pinning sites. Finally, we illustrate how to utilize laser beams as repositories that hold large numbers of vortices and how to deposit individual vortices in a sequential fashion in the repositories in order to construct superfluid flows about the repository beams with several quanta of circulation.« less
Gertjerenken, B.; Kevrekidis, P. G.; Carretero-González, R.; ...
2016-02-01
Here, we numerically investigate an experimentally viable method for generating and manipulating on-demand several vortices in a highly oblate atomic Bose-Einstein condensate (BEC) in order to initialize complex vortex distributions for studies of vortex dynamics. The method utilizes moving laser beams to generate, capture, and transport vortices inside and outside the BEC. This methodology is examined in detail and shows a wide parameter range of applicability for the prototypical two-vortex case, as well as case examples of producing and manipulating several vortices for which there is no net circulation, corresponding to equal numbers of positive and negative circulation vortices, andmore » cases for which there is one net quantum of circulation. We also find that the presence of dissipation can help stabilize the pinning of the vortices on their respective laser beam pinning sites. Finally, we illustrate how to utilize laser beams as repositories that hold large numbers of vortices and how to deposit individual vortices in a sequential fashion in the repositories in order to construct superfluid flows about the repository beams with several quanta of circulation.« less
Savoca, Marco; Lagutschenkov, Anita; Langer, Judith; Harding, Dan J; Fielicke, André; Dopfer, Otto
2013-02-14
Vibrational spectra of mixed silicon carbide clusters Si(m)C(n) with m + n = 6 in the gas phase are obtained by resonant infrared-vacuum-ultraviolet two-color ionization (IR-UV2CI for n ≤ 2) and density functional theory (DFT) calculations. Si(m)C(n) clusters are produced in a laser vaporization source, in which the silicon plasma reacts with methane. Subsequently, they are irradiated with tunable IR light from an IR free electron laser before they are ionized with UV photons from an F(2) laser. Resonant absorption of one or more IR photons leads to an enhanced ionization efficiency for Si(m)C(n) and provides the size-specific IR spectra. IR spectra measured for Si(6), Si(5)C, and Si(4)C(2) are assigned to their most stable isomers by comparison with calculated linear absorption spectra. The preferred Si(m)C(n) structures with m + n = 6 illustrate the systematic transition from chain-like geometries for bare C(6) to three-dimensional structures for bare Si(6). In contrast to bulk SiC, carbon atom segregation is observed already for the smallest n (n = 2).
NASA Astrophysics Data System (ADS)
Christen, H. M.; Rouleau, C. M.; Ohkubo, I.; Zhai, H. Y.; Lee, H. N.; Sathyamurthy, S.; Lowndes, D. H.
2003-09-01
A method for continuous compositional-spread (CCS) thin-film fabrication based on pulsed-laser deposition (PLD) is introduced. This approach is based on a translation of the substrate heater and the synchronized firing of the excimer laser, with the deposition occurring through a slit-shaped aperture. Alloying is achieved during film growth (possible at elevated temperature) by the repeated sequential deposition of submonolayer amounts. Our approach overcomes serious shortcomings in previous in situ implementation of CCS based on sputtering or PLD, in particular the variation of thickness across the compositional spread and the differing deposition energetics as a function of position. While moving-shutter techniques are appropriate for PLD approaches yielding complete spreads on small substrates (i.e., small as compared to distances over which the deposition parameters in PLD vary, typically ≈1 cm), our method can be used to fabricate samples that are large enough for individual compositions to be analyzed by conventional techniques, including temperature-dependent measurements of resistivity and dielectric and magnetic properties (i.e., superconducting quantum interference device magnetometry). Initial results are shown for spreads of (Sr1-xCax)RuO3.
Clinical results of computerized tomography-based simulation with laser patient marking.
Ragan, D P; Forman, J D; He, T; Mesina, C F
1996-02-01
Accuracy of a patient treatment portal marking device and computerized tomography (CT) simulation have been clinically tested. A CT-based simulator has been assembled based on a commercial CT scanner. This includes visualization software and a computer-controlled laser drawing device. This laser drawing device is used to transfer the setup, central axis, and/or radiation portals from the CT simulator to the patient for appropriate patient skin marking. A protocol for clinical testing is reported. Twenty-five prospectively, sequentially accessioned patients have been analyzed. The simulation process can be completed in an average time of 62 min. Under many cases, the treatment portals can be designed and the patient marked in one session. Mechanical accuracy of the system was found to be within +/- 1mm. The portal projection accuracy in clinical cases is observed to be better than +/- 1.2 mm. Operating costs are equivalent to the conventional simulation process it replaces. Computed tomography simulation is a clinical accurate substitute for conventional simulation when used with an appropriate patient marking system and digitally reconstructed radiographs. Personnel time spent in CT simulation is equivalent to time in conventional simulation.
Male-male competition, female mate choice and their interaction: determining total sexual selection.
Hunt, John; Breuker, Casper J; Sadowski, Jennifer A; Moore, Allen J
2009-01-01
Empirical studies of sexual selection typically focus on one of the two mechanisms of sexual selection without integrating these into a description of total sexual selection, or study total sexual selection without quantifying the contributions of all of the mechanisms of sexual selection. However, this can provide an incomplete or misleading view of how sexually selected traits evolve if the mechanisms of sexual selection are opposing or differ in form. Here, we take a two-fold approach to advocate a direction for future studies of sexual selection. We first show how a quantitative partitioning and examination of sexual selection mechanisms can inform by identifying illustrative studies that describe both male-male competition and female mate choice acting on the same trait. In our sample, the most common trait where this occurred was body size, and selection was typically linear. We found that male-male competition and female mate choice can be reinforcing or opposing, although the former is most common in the literature. The mechanisms of sexual selection can occur simultaneously or sequentially, and we found they were more likely to be opposing when the mechanisms operated sequentially. The degree and timing that these mechanisms interact have important implications for the operation of sexual selection and needs to be considered in designing studies. Our examples highlight where empirical data are needed. We especially lack standardized measures of the form and strength of selection imposed by each mechanism of sexual selection and how they combine to determine total sexual selection. Secondly, using quantitative genetic principles, we outline how the selection imposed by individual mechanisms can be measured and combined to estimate the total strength and form of sexual selection. We discuss the evolutionary consequences of combining the mechanisms of sexual selection and interpreting total sexual selection. We suggest how this approach may result in empirical progress in the field of sexual selection.
Optical cell cleaning with NIR femtosecond laser pulses
NASA Astrophysics Data System (ADS)
Uchugonova, Aisada; Breunig, Hans Georg; Batista, Ana; König, Karsten
2015-03-01
Femtosecond laser microscopes have been used as both micro and nanosurgery tools. The optical knock-out of undesired cells in multiplex cell clusters shall be further reported on in this study. Femtosecond laser-induced cell death is beneficial due to the reduced collateral side effects and therefore can be used to selectively destroy target cells within monolayers, as well as within 3D tissues, all the while preserving cells of interest. This is an important characteristic for the application in stem cell research and cancer treatment. Non-precise damage compromises the viability of neighboring cells by inducing side effects such as stress to the cells surrounding the target due to the changes in the microenvironment, resulting from both the laser and laser-exposed cells. In this study, optimum laser parameters for optical cleaning by isolating single cells and cell colonies are exploited through the use of automated software control. Physiological equilibrium and cellular responses to the laser induced damages are also investigated. Cell death dependence on laser focus, determination and selectivity of intensity/dosage, controllable damage and cell recovery mechanisms are discussed.
Fabrication of 10 μm-scale conductive Cu patterns by selective laser sintering of Cu complex ink
NASA Astrophysics Data System (ADS)
Min, Hyungsuk; Lee, Byoungyoon; Jeong, Sooncheol; Lee, Myeongkyu
2017-02-01
A Cu complex ink was synthesized using copper formate as a precursor and its potential for laser patterning was investigated. The Cu ink was spin-coated onto a substrate and the coated film was space-selectively sintered using a nanosecond-pulsed ultraviolet laser. The unexposed Cu ink could be removed from the film by rinsing it with the dispersing agent used to synthesize the ink, disclosing a conductive Cu pattern. A minimum resistivity of 8.46×10-5 Ω cm was obtained for the Cu lines with 10-20 μm widths. The feasibility of this method for metallization was demonstrated by fabricating a complex Cu electric circuit on an indium tin oxide-coated glass substrate. The selective laser sintering approach provides a simple, cost-effective alternative to conventional lithography for the production of electrode or metallization patterns.
Iparraguirre, I; Azkargorta, J; Balda, R; Venkata Krishnaiah, K; Jayasankar, C K; Al-Saleh, M; Fernández, J
2011-09-26
The influence of the host matrix on the spectroscopic and laser properties of Nd(3+) in a K-Ba-Al phosphate glass has been investigated as a function of rare-earth concentration. Site-selective time resolved laser spectroscopy and stimulated emission experiments under selective wavelength laser pumping show the existence of a very complex crystal field site distribution of Nd(3+) ions in this glass. The peak of the broad stimulated (4)F(3/2)→(4)I(11/2) emission shifts in a non monotonous way up to 3 nm as a function of the excitation wavelength. This behavior can be explained by the relatively moderate inter-site energy transfer among Nd(3+) ions found in this system and measured by using fluorescence line narrowing spectroscopy. The best slope efficiency obtained for the laser emission was 40%. © 2011 Optical Society of America
MacPherson, David C.; Nelson, Loren D.; O'Brien, Martin J.
1996-01-01
Apparatus performs a method of generating one or more output laser pulses in a range of 2 to 6 microns. When a plurality of the output laser pulses are generated, a first output pulse has any selected wavelength within the range and a second output pulse is temporally closely spaced relative to the first output pulse and has a chosen wavelength differing from the selected wavelength. An oscillator laser cavity is provided with a tunable oscillator rod capable of generating initial laser pulses within a range of from 750 to 1000 nm, and a tuning element is coupled to the rod. A flashlamp is operable to pump the rod. For two pulse operation, the flashlamp has a given duration. A Q-switch provides the initial laser pulses upon operation of the tuning element and the flashlamp. A Raman device coupled to the rod shifts the wavelength of such initial laser pulse into the range of from 2 to 6 microns to form the output laser pulse having a wavelength within the range. For multiple pulses, a controller causes the Q-switch to provide first and second ones of the initial laser pulses, spaced by a time interval less than the given duration. Also, a selector coupled to the tuning element is operable within such duration to successively select the wavelength of the first output pulse and the chosen wavelength of the second initial pulse. The Raman device is responsive to each of the initial light pulses to generate radiation at first and second Stokes wavelengths, each of said the output laser pulses being radiation at the second Stokes wavelength.
MacPherson, D.C.; Nelson, L.D.; O`Brien, M.J.
1996-12-10
Apparatus performs a method of generating one or more output laser pulses in a range of 2 to 6 microns. When a plurality of the output laser pulses are generated, a first output pulse has any selected wavelength within the range and a second output pulse is temporally closely spaced relative to the first output pulse and has a chosen wavelength differing from the selected wavelength. An oscillator laser cavity is provided with a tunable oscillator rod capable of generating initial laser pulses within a range of from 750 to 1000 nm, and a tuning element is coupled to the rod. A flashlamp is operable to pump the rod. For two pulse operation, the flashlamp has a given duration. A Q-switch provides the initial laser pulses upon operation of the tuning element and the flashlamp. A Raman device coupled to the rod shifts the wavelength of such initial laser pulse into the range of from 2 to 6 microns to form the output laser pulse having a wavelength within the range. For multiple pulses, a controller causes the Q-switch to provide first and second ones of the initial laser pulses, spaced by a time interval less than the given duration. Also, a selector coupled to the tuning element is operable within such duration to successively select the wavelength of the first output pulse and the chosen wavelength of the second initial pulse. The Raman device is responsive to each of the initial light pulses to generate radiation at first and second Stokes wavelengths, each of said the output laser pulses being radiation at the second Stokes wavelength. 30 figs.
Sang, Mee Kyung; Shrestha, Anupama; Kim, Du-Yeon; Park, Kyungseok; Pak, Chun Ho; Kim, Ki Deok
2013-01-01
We previously developed a sequential screening procedure to select antagonistic bacterial strains against Phytophthora capsici in pepper plants. In this study, we used a modified screening procedure to select effective biocontrol strains against P. capsici; we evaluated the effect of selected strains on Phytophthora blight and anthracnose occurrence and fruit yield in pepper plants under field and plastic house conditions from 2007 to 2009. We selected four potential biocontrol strains (Pseudomonas otitidis YJR27, P. putida YJR92, Tsukamurella tyrosinosolvens YJR102, and Novosphingobium capsulatum YJR107) among 239 bacterial strains. In the 3-year field tests, all the selected strains significantly (P < 0.05) reduced Phytophthora blight without influencing rhizosphere microbial populations; they showed similar or better levels of disease suppressions than in metalaxyl treatment in the 2007 and 2009 tests, but not in the 2008 test. In the 2-year plastic house tests, all the selected strains significantly (P < 0.05) reduced anthracnose incidence in at least one of the test years, but their biocontrol activities were variable. In addition, strains YJR27, YJR92, and YJR102, in certain harvests, increased pepper fruit numbers in field tests and red fruit weights in plastic house tests. Taken together, these results indicate that the screening procedure is rapid and reliable for the selection of potential biocontrol strains against P. capsici in pepper plants. In addition, these selected strains exhibited biocontrol activities against anthracnose, and some of the strains showed plant growth-promotion activities on pepper fruit. PMID:25288942
NASA Astrophysics Data System (ADS)
Serkez, S.; Geloni, G.; Tomin, S.; Feng, G.; Gryzlova, E. V.; Grum-Grzhimailo, A. N.; Meyer, M.
2018-02-01
The generation of attosecond, highbrightness x-ray pulses is a matter of great interest given their applications in the study of ultra-fast processes. In recent years, the production of x-ray pulses of high brightness, both in the soft and in the hard x-ray range, has been enabled by x-ray free-electron lasers (XFELs). In contrast to conventional quantum lasers, XFELs are based on the use of an ultra-relativistic electron beam as gain medium. They often work in the self-amplified spontaneous emission (SASE) regime, which provides pulses of duration down to a few femtoseconds, composed of several longitudinal modes. In order to further decrease the duration of these pulses, special methods need to be implemented. In this paper we review available methods, with particular focus on the x-ray laser-enhanced attosecond pulse generation, which is one of the most promising techniques. We illustrate the method using the SASE3 soft x-ray undulator of the European XFEL facility as a case study, emphasizing the importance of high-repetition rate attosecond x-ray pulses. The expected attosecond-level radiation output is used for simulations of sequential ionization processes in atoms in the case of ionization in the soft x-ray regime, demonstrating the importance of this opportunity for the user community.
Burillo, Almudena; Rodríguez-Sánchez, Belén; Ramiro, Ana; Cercenado, Emilia; Rodríguez-Créixems, Marta; Bouza, Emilio
2014-01-01
Microbiological confirmation of a urinary tract infection (UTI) takes 24-48 h. In the meantime, patients are usually given empirical antibiotics, sometimes inappropriately. We assessed the feasibility of sequentially performing a Gram stain and MALDI-TOF MS mass spectrometry (MS) on urine samples to anticipate clinically useful information. In May-June 2012, we randomly selected 1000 urine samples from patients with suspected UTI. All were Gram stained and those yielding bacteria of a single morphotype were processed for MALDI-TOF MS. Our sequential algorithm was correlated with the standard semiquantitative urine culture result as follows: Match, the information provided was anticipative of culture result; Minor error, the information provided was partially anticipative of culture result; Major error, the information provided was incorrect, potentially leading to inappropriate changes in antimicrobial therapy. A positive culture was obtained in 242/1000 samples. The Gram stain revealed a single morphotype in 207 samples, which were subjected to MALDI-TOF MS. The diagnostic performance of the Gram stain was: sensitivity (Se) 81.3%, specificity (Sp) 93.2%, positive predictive value (PPV) 81.3%, negative predictive value (NPV) 93.2%, positive likelihood ratio (+LR) 11.91, negative likelihood ratio (-LR) 0.20 and accuracy 90.0% while that of MALDI-TOF MS was: Se 79.2%, Sp 73.5, +LR 2.99, -LR 0.28 and accuracy 78.3%. The use of both techniques provided information anticipative of the culture result in 82.7% of cases, information with minor errors in 13.4% and information with major errors in 3.9%. Results were available within 1 h. Our serial algorithm provided information that was consistent or showed minor errors for 96.1% of urine samples from patients with suspected UTI. The clinical impacts of this rapid UTI diagnosis strategy need to be assessed through indicators of adequacy of treatment such as a reduced time to appropriate empirical treatment or earlier withdrawal of unnecessary antibiotics.
Sun, Shu Yang; Gong, Han Sheng; Zhao, Yu Ping; Liu, Wen Li; Jin, Cheng Wu
2016-04-01
There has been limited research on the use of non-Saccharomyces yeasts for the production of cherry wines. This work used an autochthonous Torulaspora delbrueckii strain 49 (TD49) in association with a commercial S. cerevisiae RC212 yeast, to investigate the effect of multi-starter culture (sequential inoculation and simultaneous inoculation) and fermentation temperature on the quality of cherry wines. Both TD49 and RC212 proliferated during alcoholic fermentation (AF) under sequential inoculation conditions, whereas in the case of simultaneous inoculation, TD49 increased slowly at first and then declined sharply near the fermentation end. The analytical profile showed that both mixed fermentations produced lower levels of volatile acidy and higher levels of aromatic compounds than those from RC212 mono-culture. During sensory analysis, wines from sequential fermentation obtained the highest score, mainly due to the higher intensity in 'fruity' and 'floral' characters. As for the influence of temperature, a low temperature (20 °C) enhanced TD49 persistence during AF, but the sensory quality decreased anyway; 30 °C resulted in decreases in most measured descriptors. Therefore, 25 °C was selected as the best culture temperature. TD49/RC212 sequential inoculation and fermentation at 25 °C significantly enhanced the cherry wine quality. © 2015 Society of Chemical Industry.
Ale, Cesar E; Farías, Marta E; Strasser de Saad, Ana M; Pasteris, Sergio E
2014-07-01
Growth and fermentation patterns of Saccharomyces cerevisiae, Kloeckera apiculata, and Oenococcus oeni strains cultured in grape juice medium were studied. In pure, sequential and simultaneous cultures, the strains reached the stationary growth phase between 2 and 3 days. Pure and mixed K. apiculata and S. cerevisiae cultures used mainly glucose, producing ethanol, organic acids, and 4.0 and 0.1 mM glycerol, respectively. In sequential cultures, O. oeni achieved about 1 log unit at 3 days using mainly fructose and L-malic acid. Highest sugars consumption was detected in K. apiculata supernatants, lactic acid being the major end-product. 8.0 mM glycerol was found in 6-day culture supernatants. In simultaneous cultures, total sugars and L-malic acid were used at 3 days and 98% of ethanol and glycerol were detected. This study represents the first report of the population dynamics and metabolic behavior of yeasts and O. oeni in sequential and simultaneous cultures and contributes to the selection of indigenous strains to design starter cultures for winemaking, also considering the inclusion of K. apiculata. The sequential inoculation of yeasts and O. oeni would enhance glycerol production, which confers desirable organoleptic characteristics to wines, while organic acids levels would not affect their sensory profile. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Remote measurement of ClO in the stratosphere
NASA Technical Reports Server (NTRS)
Menzies, R. T.
1979-01-01
ClO has been detected in the stratosphere from observations of the solar spectrum in the infrared, in a small spectral interval near 12 micrometers. The observations were made with a balloon-borne laser heterodyne radiometer, launched from Palestine, Texas on September 20. By comparing high sun spectra with a number of sequential spectra taken during sunset, an altitude profile has been calculated in the 29-38 km altitude range. The results show a peak mixing ratio in excess of one ppb above 34 km, and a rapid decrease in mixing ratio with decreasing altitude below 34 km.
Laser Photoradiation Therapy For Neonatal Jaundice
NASA Astrophysics Data System (ADS)
Hamza, Mostafa; Hamza, Mohammad
1987-04-01
This paper describes our leading experience in the clinical application of laser in the treatment of neonatal jaundice. Currently, the irradiation of jaundiced infants during neonatal life to fluorescent light is the most common treatment of neonatal hyperbilirubinemia. The authors have investigated the photodegradation of bilirubin by laser in vitro and in Gunn rats before embarking on its clinical application in the treatment of jaundice in the new born child. This work was done to study the theraputic effect of laser compared to the currently used phototherapy in the treatment of neonatal jaundice. We selected 16 full term neonates with jaundice to be the subject of this study. The neonates of the study were devided into two groups. The first group was treated with continuous phototherapy . The second group recieved photoradiation therapy with gas laser The laser used was a CW argon-ion laser tuned to oscillate at 488.0 nm wavelength. This wavelength selection was based on our previous studies on the effect of laser irradiation of Gunn rats at different wavelengths. Comparison of the results of both methods of treatment will be reported in detail. The advantages and limitations of laser photoradiation therapy for neonatal jaundice will be discussed.
A 532 nm Chaotic Fiber Laser Transmitter for Underwater Lidar
2013-04-23
passes through unaffected. 3.1.1.2 Ring Lasers as Oscillators The simplest form of laser is a called a Fabry - Perot laser, in which two reflectors are...insufficient to drive the gain amplifier, and so the circulator-based design was scrapped in favor of the Fabry - Perot , whose efficiency was far better...Bidirectional Ring and Fabry - Perot Lasers The Fabry - Perot laser used two matched FBGs to create a wavelength-selective resonator cavity. First single- and
Tunable mode and line selection by injection in a TEA CO2 laser
NASA Technical Reports Server (NTRS)
Menzies, R. T.; Flamant, P. H.; Kavaya, M. J.; Kuiper, E. N.
1984-01-01
Tunable mode selection by injection in pulsed CO2 lasers is examined, and both analytical and numerical models are used to compute the required injection power for a variety of experimental cases. These are treated in two categories: mode selection at a desired frequency displacement from the center frequency of a transition line in a dispersive cavity and mode (and line) selection at the center frequency of a selected transition line in a nondispersive cavity. The results point out the potential flexibility of pulsed injection in providing wavelength tunable high-energy single-frequency pulses.
Selective mode excitation in finite size plasma crystals by diffusely reflected laser light
NASA Astrophysics Data System (ADS)
Schablinski, Jan; Block, Dietmar
2015-02-01
The possibility to use diffuse reflections of a laser beam to exert a force on levitating dust particles is studied experimentally. Measurements and theoretical predictions are found to be in good agreement. Further, the method is applied to test the selective excitation of breathing-like modes in finite dust clusters.
Actively learning human gaze shifting paths for semantics-aware photo cropping.
Zhang, Luming; Gao, Yue; Ji, Rongrong; Xia, Yingjie; Dai, Qionghai; Li, Xuelong
2014-05-01
Photo cropping is a widely used tool in printing industry, photography, and cinematography. Conventional cropping models suffer from the following three challenges. First, the deemphasized role of semantic contents that are many times more important than low-level features in photo aesthetics. Second, the absence of a sequential ordering in the existing models. In contrast, humans look at semantically important regions sequentially when viewing a photo. Third, the difficulty of leveraging inputs from multiple users. Experience from multiple users is particularly critical in cropping as photo assessment is quite a subjective task. To address these challenges, this paper proposes semantics-aware photo cropping, which crops a photo by simulating the process of humans sequentially perceiving semantically important regions of a photo. We first project the local features (graphlets in this paper) onto the semantic space, which is constructed based on the category information of the training photos. An efficient learning algorithm is then derived to sequentially select semantically representative graphlets of a photo, and the selecting process can be interpreted by a path, which simulates humans actively perceiving semantics in a photo. Furthermore, we learn a prior distribution of such active graphlet paths from training photos that are marked as aesthetically pleasing by multiple users. The learned priors enforce the corresponding active graphlet path of a test photo to be maximally similar to those from the training photos. Experimental results show that: 1) the active graphlet path accurately predicts human gaze shifting, and thus is more indicative for photo aesthetics than conventional saliency maps and 2) the cropped photos produced by our approach outperform its competitors in both qualitative and quantitative comparisons.
Wong, Andrew T; Shao, Meng; Rineer, Justin; Lee, Anna; Schwartz, David; Schreiber, David
2017-06-01
The objective of this study was to analyze the impact on overall survival (OS) from the addition of postoperative radiation with or without chemotherapy after esophagectomy, using a large, hospital-based dataset. Previous retrospective studies have suggested an OS advantage for postoperative chemoradiation over surgery alone, although prospective data are lacking. The National Cancer Data Base was queried to select patients diagnosed with stage pT3-4Nx-0M0 or pT1-4N1-3M0 esophageal carcinoma (squamous cell or adenocarcinoma) from 1998 to 2011 treated with definitive esophagectomy ± postoperative radiation and/or chemotherapy. OS was analyzed using the Kaplan-Meier method and compared using the log-rank test. Multivariate Cox regression analysis was used to identify covariates associated with OS. There were 4893 patients selected, of whom 1153 (23.6%) received postoperative radiation. Most patients receiving radiation also received sequential/concomitant chemotherapy (89.9%). For the entire cohort, postoperative radiation was associated with a statistically significant but modest absolute improvement in survival (hazard ratio 0.77; 95% CI, 0.71-0.83; P < 0.001). On subgroup analysis, postoperative radiation was associated with improved OS for patients with node-positive disease (3-yr OS 34.3 % vs 27.8%, P < 0.001) or positive margins (3-yr OS 36.4% vs 18.0%, P < 0.001). When chemotherapy usage was incorporated, sequential chemotherapy was associated with the best survival (P < 0.001). Multivariate analysis revealed that the addition of chemotherapy to radiation therapy, whether sequentially or concurrently, was a strong prognostic factor for OS. In this hospital-based study, the addition of postoperative chemoradiation (either sequentially or concomitantly) after esophagectomy was associated with improved OS for patients with node-positive disease or positive margins.
NASA Astrophysics Data System (ADS)
Watanabe, Wataru; Shimada, Tomoko; Matsunaga, Sachihiro; Kurihara, Daisuke; Arimura, Shin-ichi; Tsutsumi, Nobuhiro; Fukui, Kiichi; Itoh, Kazuyoshi
2008-02-01
We present space-selective labeling of organelles by using two-photon conversion of a photoconvertible fluorescent protein with near-infrared femtosecond laser pulses. Two-photon excitation of photoconvertible fluorescent-protein, Kaede, enables space-selective labeling of organelles. We alter the fluorescence of target mitochondria in a tobacco BY-2 cell from green to red by focusing femtosecond laser pulses with a wavelength of 750 nm.
Schindlbeck, Christopher; Pape, Christian; Reithmeier, Eduard
2018-04-16
Alignment of optical components is crucial for the assembly of optical systems to ensure their full functionality. In this paper we present a novel predictor-corrector framework for the sequential assembly of serial optical systems. Therein, we use a hybrid optical simulation model that comprises virtual and identified component positions. The hybrid model is constantly adapted throughout the assembly process with the help of nonlinear identification techniques and wavefront measurements. This enables prediction of the future wavefront at the detector plane and therefore allows for taking corrective measures accordingly during the assembly process if a user-defined tolerance on the wavefront error is violated. We present a novel notation for the so-called hybrid model and outline the work flow of the presented predictor-corrector framework. A beam expander is assembled as demonstrator for experimental verification of the framework. The optical setup consists of a laser, two bi-convex spherical lenses each mounted to a five degree-of-freedom stage to misalign and correct components, and a Shack-Hartmann sensor for wavefront measurements.
Leitner, T.; Mazza, T.; Schröder, H.; Kunnus, K.; Schreck, S.; Radcliffe, P.; Düsterer, S.; Meyer, M.; Föhlisch, A.
2017-01-01
We prove the hitherto hypothesized sequential dissociation of Fe(CO)5 in the gas phase upon photoexcitation at 266 nm via a singlet pathway with time-resolved valence and core-level photoelectron spectroscopy with an x-ray free-electron laser. Valence photoelectron spectra are used to identify free CO molecules and to determine the time constants of stepwise dissociation to Fe(CO)4 within the temporal resolution of the experiment and further to Fe(CO)3 within 3 ps. Fe 3p core-level photoelectron spectra directly reflect the singlet spin state of the Fe center in Fe(CO)5, Fe(CO)4, and Fe(CO)3 showing that the dissociation exclusively occurs along a singlet pathway without triplet-state contribution. Our results are important for assessing intra- and intermolecular relaxation processes in the photodissociation dynamics of the prototypical Fe(CO)5 complex in the gas phase and in solution, and they establish time-resolved core-level photoelectron spectroscopy as a powerful tool for determining the multiplicity of transition metals in photochemical reactions of coordination complexes. PMID:28595420
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feliz, M.; Ferraudi, G.
1992-04-02
Photochemical reactions of fac-ClRe(CO){sub 3}L{sub 2} (L=4-phenylpyridine or 4-cyanopyridine), were investigated by sequential biphotonic excitations: one laser flash was used for the preparation of the compounds in the lowest lying MLCT (Re{r_arrow}) state and another flash for the irradiation of the compounds in such excited states. These photolyses led to photodecompostions into CIRe(CO){sub 3}L{sup +} and L{sup .} in a charge transfer state placed 40 Kk above ground state. Quantum yields determined or various excitation energies show that not all the excited state populated in monophotonic excitations can be reached under the sequential biphotonic regime. Therefore, photogeneration of the biradicalmore » intermediate, ClRe(CO){sub 3}L{sup +} and L{sup .}, from ligand-centered states has not been detected in these experiments. Results from monophotonic and biphotonic excitations have been used for a semiquantitative mapping of the excited-state potential surfaces. 41 refs., 6 figs.« less
NASA Astrophysics Data System (ADS)
Coman, Tudor; Timpu, Daniel; Nica, Valentin; Vitelaru, Catalin; Rambu, Alicia Petronela; Stoian, George; Olaru, Mihaela; Ursu, Cristian
2017-10-01
Highly conductive transparent Al-doped ZnO (AZO) thin films were obtained at room temperature through sequential PLD (SPLD) from Zn and Al metallic targets in an oxygen/argon gas mixture. We have investigated the structural, electrical and optical properties as a function of the oxygen/argon pressure ratio in the chamber. The measured Hall carrier concentration was found to increase with argon injection from 1.3 × 1020 to 6.7 × 1020 cm-3, while the laser shots ratio for Al/Zn targets ablation was kept constant. This increase was attributed to an enhancement of the substitution doping into the ZnO lattice. The argon injection also leads to an increase of the Hall mobility up to 20 cm2 V-1 s-1, attributed to a reduction of interstitial-type defects. Thus, the approach of using an oxygen/argon gas mixture during SPLD from metallic targets allows obtaining at room temperature AZO samples with high optical transmittance (about 90%) and low electrical resistivity (down to 5.1 × 10-4 Ω cm).
2007-06-01
information than another party, such as in the market for used cars. Mankiw , in his book, “The Principles of Economics ,” defines adverse selection as...Options,” Power Point presentation e-mailed to the author, 18 May 2007, 1-9. 37 Ibid., 2. 38 Gregory N. Mankiw , Principles of Economics , Third...the Internet.” The American Economic Review. December 1999. 89 No. 5. 1066- 1078. Mankiw , Gregory N. Principles of Economics , Third Edition (Mason