Pietrowska, M; Marczak, L; Polanska, J; Nowicka, E; Behrent, K; Tarnawski, R; Stobiecki, M; Polanski, A; Widlak, P
2010-01-01
Mass spectrometry-based analysis of the serum proteome allows identifying multi-peptide patterns/signatures specific for blood of cancer patients, thus having high potential value for cancer diagnostics. However, because of problems with optimization and standardization of experimental and computational design, none of identified proteome patterns/signatures was approved for diagnostics in clinical practice as yet. Here we compared two methods of serum sample preparation for mass spectrometry-based proteome pattern analysis aimed to identify biomarkers that could be used in early detection of breast cancer patients. Blood samples were collected in a group of 92 patients diagnosed at early (I and II) stages of the disease before the start of therapy, and in a group of age-matched healthy controls (104 women). Serum specimens were purified and analyzed using MALDI-ToF spectrometry, either directly or after membrane filtration (50 kDa cut-off) to remove albumin and other large serum proteins. Mass spectra of the low-molecular-weight fraction (2-10 kDa) of the serum proteome were resolved using the Gaussian mixture decomposition, and identified spectral components were used to build classifiers that differentiated samples from breast cancer patients and healthy persons. Mass spectra of complete serum and membrane-filtered albumin-depleted samples have apparently different structure and peaks specific for both types of samples could be identified. The optimal classifier built for the complete serum specimens consisted of 8 spectral components, and had 81% specificity and 72% sensitivity, while that built for the membrane-filtered samples consisted of 4 components, and had 80% specificity and 81% sensitivity. We concluded that pre-processing of samples to remove albumin might be recommended before MALDI-ToF mass spectrometric analysis of the low-molecular-weight components of human serum Keywords: albumin removal; breast cancer; clinical proteomics; mass spectrometry; pattern analysis; serum proteome.
Bead-based microfluidic immunoassay for diagnosis of Johne's disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wadhwa, Ashutosh; Foote, Robert; Shaw, Robert W
2012-01-01
Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types ofmore » SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.« less
Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A
2006-06-01
To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc
2018-04-06
Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.
IL8 and IL16 levels indicate serum and plasma quality.
Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay
2018-02-09
Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.
Burns, J; Hou, S; Riley, C B; Shaw, R A; Jewett, N; McClure, J T
2014-01-01
Rapid, economical, and quantitative assays for measurement of camelid serum immunoglobulin G (IgG) are limited. In camelids, failure of transfer of maternal immunoglobulins has a reported prevalence of up to 20.5%. An accurate method for quantifying serum IgG concentrations is required. To develop an infrared spectroscopy-based assay for measurement of alpaca serum IgG and compare its performance to the reference standard radial immunodiffusion (RID) assay. One hundred and seventy-five privately owned, healthy alpacas. Eighty-two serum samples were collected as convenience samples during routine herd visits whereas 93 samples were recruited from a separate study. Serum IgG concentrations were determined by RID assays and midinfrared spectra were collected for each sample. Fifty samples were set aside as the test set and the remaining 125 training samples were employed to build a calibration model using partial least squares (PLS) regression with Monte Carlo cross validation to determine the optimum number of PLS factors. The predictive performance of the calibration model was evaluated by the test set. Correlation coefficients for the IR-based assay were 0.93 and 0.87, respectively, for the entire data set and test set. Sensitivity in the diagnosis of failure of transfer of passive immunity (FTPI) ([IgG] <1,000 mg/dL) was 71.4% and specificity was 100% for the IR-based method (test set) as gauged relative to the RID reference method assay. This study indicated that infrared spectroscopy, in combination with chemometrics, is an effective method for measurement of IgG in alpaca serum. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Panyasing, Yaowalak; Kedkovid, Roongtham; Thanawongnuwech, Roongroje; Kittawornrat, Apisit; Ji, Ju; Giménez-Lirola, Luis; Zimmerman, Jeffrey
2018-03-01
Early recognition and rapid elimination of infected animals is key to controlling incursions of classical swine fever virus (CSFV). In this study, the diagnostic characteristics of 10 CSFV assays were evaluated using individual serum (n = 601) and/or oral fluid (n = 1417) samples collected from -14 to 28 days post inoculation (DPI). Serum samples were assayed by virus isolation (VI), 2 commercial antigen-capture enzyme-linked immunosorbent assays (ELISA), virus neutralization (VN), and 3 antibody ELISAs. Both serum and oral fluid samples were tested with 3 commercial real-time reverse transcription-polymerase chain reaction (rRT-PCR) assays. One or more serum samples was positive by VI from DPIs 3 to 21 and by antigen-capture ELISAs from DPIs 6 to 17. VN-positive serum samples were observed at DPIs ≥ 7 and by antibody ELISAs at DPIs ≥ 10. CSFV RNA was detected in serum samples from DPIs 2 to 28 and in oral fluid samples from DPIs 4 to 28. Significant differences in assay performance were detected, but most importantly, no single combination of sample and assay was able to dependably identify CSFV-inoculated pigs throughout the 4-week course of the study. The results show that effective surveillance for CSFV, especially low virulence strains, will require the use of PCR-based assays for the detection of early infections (<14 days) and antibody-based assays, thereafter. Copyright © 2018 Elsevier B.V. All rights reserved.
Burki, Umar; Straub, Volker
2017-01-01
Determining the concentration of oligonucleotide in biological samples such as tissue lysate and serum is essential for determining the biodistribution and pharmacokinetic profile, respectively. ELISA-based assays have shown far greater sensitivities compared to other methods such as HPLC and LC/MS. Here, we describe a novel ultrasensitive hybridization-based ELISA method for quantitating morpholino oligonucleotides in mouse tissue lysate and serum samples. The assay has a linear detection range of 5-250 pM (R2 > 0.99).
Borchardt, Stefan; Staufenbiel, Rudolf
2012-04-15
To evaluate the use of nonesterified fatty acids (NEFA) and β-hydroxybutyrate (BHBA) concentrations in pooled serum samples for herd-based detection of subclinical ketosis (SCK) in dairy cows after calving. Cross-sectional study. 1,100 dairy cows from 110 herds. Blood samples were collected from 10 healthy cows/herd in the first week after parturition. Aliquots of serum were mixed to create a pooled sample. Concentrations of NEFA and BHBA were measured to estimate prevalence of SCK. Pooled sample test results were compared with those obtained for individual samples. Linear regression and receiver-operating characteristic curve analysis were performed; Bland-Altman plots were used to evaluate agreement between methods. Overall prevalence of SCK was 30.7%, 19.3%, and 13.6%, as determined by use of BHBA threshold concentrations of 1,000, 1,200, and 1,400 μmol/L, respectively. Pooled sample concentrations of NEFA and BHBA were significantly correlated (r = 0.98 and 0.97, respectively) with individual sample means and with the number of cows that had NEFA (R(2) range, 0.81 to 0.84) or BHBA (R(2) range, 0.65 to 0.76) concentrations above predefined thresholds. Pooled sample concentrations of NEFA and BHBA were very accurate to highly accurate for herd-based detection of SCK. Analysis of NEFA and BHBA concentrations in pooled serum samples was useful for herd-based detection of SCK. A sample size of 10 cows/herd was deemed adequate for monitoring dairy herds for SCK. Reference criteria specific to pooled samples should be used for this type of herd-based testing.
Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo
2016-09-07
Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.
Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R.; Fernandes, Daryl L.; Satsangi, Jack; Spencer, Daniel I. R.
2015-01-01
Introduction Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. Methods 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. Results There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. Conclusions The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures. PMID:25831126
Ventham, Nicholas T; Gardner, Richard A; Kennedy, Nicholas A; Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R; Fernandes, Daryl L; Satsangi, Jack; Spencer, Daniel I R
2015-01-01
Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures.
Gao, Le; Li, Jian; Wu, Yandan; Yu, Miaohao; Chen, Tian; Shi, Zhixiong; Zhou, Xianqing; Sun, Zhiwei
2016-11-01
Two simple and efficient pretreatment procedures have been developed for the simultaneous extraction and cleanup of six novel brominated flame retardants (NBFRs) and eight common polybrominated diphenyl ethers (PBDEs) in human serum. The first sample pretreatment procedure was a quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based approach. An acetone/hexane mixture was employed to isolate the lipid and analytes from the serum with a combination of MgSO 4 and NaCl, followed by a dispersive solid-phase extraction (d-SPE) step using C18 particles as a sorbent. The second sample pretreatment procedure was based on solid-phase extraction. The sample extraction and cleanup were conducted directly on an Oasis HLB SPE column using 5 % aqueous isopropanol, concentrated sulfuric acid, and 10 % aqueous methanol, followed by elution with dichloromethane. The NBFRs and PBDEs were then detected using gas chromatography-negative chemical ionization mass spectrometry (GC-NCI MS). The methods were assessed for repeatability, accuracy, selectivity, limits of detection (LODs), and linearity. The results of spike recovery experiments in fetal bovine serum showed that average recoveries ranged from 77.9 % to 128.8 % with relative standard deviations (RSDs) from 0.73 % to 12.37 % for most of the analytes. The LODs for the analytes in fetal bovine serum ranged from 0.3 to 50.8 pg/mL except for decabromodiphenyl ethane. The proposed method was successfully applied to the determination of the 14 brominated flame retardants in human serum. The two pretreatment procedures described here are simple, accurate, and precise, and are suitable for the routine analysis of human serum. Graphical Abstract Workflow of a QuEChERS-based approach (top) and an SPE-based approach (bottom) for the detection of PBDEs and NBFRs in serum.
Meyer, Sören; Markova, Mariya; Pohl, Gabriele; Marschall, Talke A; Pivovarova, Olga; Pfeiffer, Andreas F H; Schwerdtle, Tanja
2018-09-01
Multi-element determination in human samples is very challenging. Especially in human intervention studies sample volumes are often limited to a few microliters and due to the high number of samples a high-throughput is indispensable. Here, we present a state-of-the-art ICP-MS/MS-based method for the analysis of essential (trace) elements, namely Mg, Ca, Fe, Cu, Zn, Mo, Se and I, as well as food-relevant toxic elements such as As and Cd. The developed method was validated regarding linearity of the calibration curves, method LODs and LOQs, selectivity and trueness as well as precision. The established reliable method was applied to quantify the element serum concentrations of participants of a human intervention study (LeguAN). The participants received isocaloric diets, either rich in plant protein or in animal protein. While the serum concentrations of Mg and Mo increased in participants receiving the plant protein-based diet (above all legumes), the Se concentration in serum decreased. In contrast, the animal protein-based diet, rich in meat and dairy products, resulted in an increased Se concentration in serum. Copyright © 2018 Elsevier GmbH. All rights reserved.
Use of Paired Serum Samples for Serodiagnosis of Typhoid Fever
House, Deborah; Chinh, Nguyen T.; Diep, To S.; Parry, Christopher M.; Wain, John; Dougan, Gordon; White, Nicholas J.; Hien, Tran Tinh; Farrar, Jeremy J.
2005-01-01
Using an enzyme-linked immunosorbent assay we demonstrate that, in adult patients with typhoid fever, the sensitivity of a serological test based on the detection of anti-lipopolysaccharide immunoglobulin G is increased when used with paired serum samples taken 1 week apart. PMID:16145168
Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics
2011-01-01
Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin) make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent) displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma) in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers. PMID:21554704
Elsohaby, Ibrahim; McClure, J Trenton; Riley, Christopher B; Bryanton, Janet; Bigsby, Kathryn; Shaw, R Anthony
2018-02-20
Attenuated total reflectance infrared (ATR-IR) spectroscopy is a simple, rapid and cost-effective method for the analysis of serum. However, the complex nature of serum remains a limiting factor to the reliability of this method. We investigated the benefits of coupling the centrifugal ultrafiltration with ATR-IR spectroscopy for quantification of human serum IgA concentration. Human serum samples (n = 196) were analyzed for IgA using an immunoturbidimetric assay. ATR-IR spectra were acquired for whole serum samples and for the retentate (residue) reconstituted with saline following 300 kDa centrifugal ultrafiltration. IR-based analytical methods were developed for each of the two spectroscopic datasets, and the accuracy of each of the two methods compared. Analytical methods were based upon partial least squares regression (PLSR) calibration models - one with 5-PLS factors (for whole serum) and the second with 9-PLS factors (for the reconstituted retentate). Comparison of the two sets of IR-based analytical results to reference IgA values revealed improvements in the Pearson correlation coefficient (from 0.66 to 0.76), and the root mean squared error of prediction in IR-based IgA concentrations (from 102 to 79 mg/dL) for the ultrafiltration retentate-based method as compared to the method built upon whole serum spectra. Depleting human serum low molecular weight proteins using a 300 kDa centrifugal filter thus enhances the accuracy IgA quantification by ATR-IR spectroscopy. Further evaluation and optimization of this general approach may ultimately lead to routine analysis of a range of high molecular-weight analytical targets that are otherwise unsuitable for IR-based analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Dalgard, Clifton L; Polston, Keith F; Sukumar, Gauthaman; Mallon, Col Timothy M; Wilkerson, Matthew D; Pollard, Harvey B
2016-08-01
The aim of this study was to identify serum microRNA (miRNA) biomarkers that indicate deployment-associated exposures in service members at military installations with open burn pits. Another objective was to determine detection rates of miRNAs in Department of Defense Serum Repository (DoDSR) samples with a high-throughput methodology. Low-volume serum samples (n = 800) were profiled by miRNA-capture isolation, pre-amplification, and measurement by a quantitative PCR-based OpenArray platform. Normalized quantitative cycle values were used for differential expression analysis between groups. Assay specificity, dynamic range, reproducibility, and detection rates by OpenArray passed target desired specifications. Serum abundant miRNAs were consistently measured in study specimens. Four miRNAs were differentially expressed in the case deployment group subjects. miRNAs are suitable RNA species for biomarker discovery in the DoDSR serum specimens. Serum miRNAs are candidate biomarkers for deployment and environmental exposure in military service members.
Exposure of Piglets to Enteroviruses Investigated by an Immunoassay Based on the EV-G1 VP4 Peptide.
Benkahla, Mehdi A; Sane, Famara; Desailloud, Rachel; Hober, Didier
2016-01-01
The aim of this study was to investigate the exposure of piglets to enteroviruses-G (EV-G) through the presence of antibodies in their serum. Serum samples were obtained from the vena cava of 10 piglets at 9 weeks of age and again 39 days later (day 39). They were tested using an immunoassay based on the EV-G1 VP4 peptide, since VP4 is highly conserved among the four Enterovirus capsid proteins, and by using a seroneutralization assay. For each serum collected on day 39 the optical density was high compared to the value obtained in serum collected earlier (p = 0.002). However, the titers of anti-EV-G1 serum neutralizing activity were not different in paired samples (p > 0.999). The sequence alignment of the EV-G1 VP4 peptide, encompassing 50 amino acids, used in the immunoassay showed 88% homology with EV-G, suggesting that antibodies directed toward other EV-G than EV-G1 may be detected. An immunoassay based on EV-G1 VP4 can detect an increased level of EV-G antibodies in piglet serum samples. Further studies are needed to determine whether this immunoassay may be useful for diagnosis and/or epidemiological studies and to monitor EV-G infection in pigs to evaluate strategies aimed to prevent enterovirus infections. © 2016 S. Karger AG, Basel.
Iwama, Ryosuke; Sato, Tsubasa; Katayama, Masaaki; Shimamura, Shunsuke; Satoh, Hiroshi; Ichijo, Toshihiro; Furuhama, Kazuhisa
2015-08-01
We examined the correlation between the glomerular filtration rate (GFR) estimated from an equation based on the serum iodixanol clearance technique and International Renal Interest Society (IRIS) stages of chronic kidney disease (CKD) in cats. The equation included the injection dose, sampling time, serum concentration and estimated volume of distribution (Vd) of the isotonic, nonionic, contrast medium iodixanol as a test tracer. The percent changes in the median basal GFR values calculated from the equation in CKD cats resembled those of IRIS stages 1-3. These data validate the association between the GFR derived from the simplified equation and IRIS stages based on the serum creatinine concentration in cats with CKD. They describe the GFR ranges determined using single-sample iodixanol clearance for healthy cats and cats with various IRIS stages of CKD.
Analysis of biofluids in aqueous environment based on mid-infrared spectroscopy.
Fabian, Heinz; Lasch, Peter; Naumann, Dieter
2005-01-01
In this study we describe a semiautomatic Fourier transform infrared spectroscopic methodology for the analysis of liquid serum samples, which combines simple sample introduction with high sample throughput. The applicability of this new infrared technology to the analysis of liquid serum samples from a cohort of cattle naturally infected with bovine spongiform encephalopathy and from controls was explored in comparison to the conventional approach based on transmission infrared spectroscopy of dried serum films. Artifical neural network analysis of the infrared data was performed to differentiate between bovine spongiform encephalopathy-negative controls and animals in the late stage of the disease. After training of artifical neural network classifiers, infrared spectra of sera from an independent external validation data set were analyzed. In this way, sensitivities between 90 and 96% and specificities between 84 and 92% were achieved, respectively, depending upon the strategy of data collection and data analysis. Based on these results, the advantages and limitations of the liquid sample technique and the dried film approach for routine analysis of biofluids are discussed. 2005 Society of Photo-Optical Instrumentation Engineers.
Berger, Sanne Schou; Lauritsen, Klara Tølbøll; Boas, Ulrik; Lind, Peter; Andresen, Lars Ole
2017-11-01
We developed and made a preliminary validation of a bead-based multiplexed immunoassay for simultaneous detection of porcine serum antibodies to Actinobacillus pleuropneumoniae serovars 1, 2, 6, 7, and 12. Magnetic fluorescent beads were coupled with A. pleuropneumoniae antigens and tested with a panel of serum samples from experimentally infected pigs and with serum samples from uninfected and naturally infected pigs. The multiplex assay was compared to in-house ELISAs and complement fixation (CF) tests, which have been used for decades as tools for herd classification in the Danish Specific Pathogen Free system. Assay specificities and sensitivities as well as the corresponding cutoff values were determined using receiver operating characteristic (ROC) curve analysis, and the A. pleuropneumoniae multiplex assay showed good correlation with the in-house ELISAs and CF tests with areas under ROC curves ≥ 0.988. Benefits of multiplexed assays compared to ELISAs and CF tests include reduced serum sample volumes needed for analysis, less labor, and shorter assay time.
Giménez-Lirola, Luis G; Mur, Lina; Rivera, Belen; Mogler, Mark; Sun, Yaxuan; Lizano, Sergio; Goodell, Christa; Harris, D L Hank; Rowland, Raymond R R; Gallardo, Carmina; Sánchez-Vizcaíno, José Manuel; Zimmerman, Jeff
2016-01-01
In the absence of effective vaccine(s), control of African swine fever caused by African swine fever virus (ASFV) must be based on early, efficient, cost-effective detection and strict control and elimination strategies. For this purpose, we developed an indirect ELISA capable of detecting ASFV antibodies in either serum or oral fluid specimens. The recombinant protein used in the ELISA was selected by comparing the early serum antibody response of ASFV-infected pigs (NHV-p68 isolate) to three major recombinant polypeptides (p30, p54, p72) using a multiplex fluorescent microbead-based immunoassay (FMIA). Non-hazardous (non-infectious) antibody-positive serum for use as plate positive controls and for the calculation of sample-to-positive (S:P) ratios was produced by inoculating pigs with a replicon particle (RP) vaccine expressing the ASFV p30 gene. The optimized ELISA detected anti-p30 antibodies in serum and/or oral fluid samples from pigs inoculated with ASFV under experimental conditions beginning 8 to 12 days post inoculation. Tests on serum (n = 200) and oral fluid (n = 200) field samples from an ASFV-free population demonstrated that the assay was highly diagnostically specific. The convenience and diagnostic utility of oral fluid sampling combined with the flexibility to test either serum or oral fluid on the same platform suggests that this assay will be highly useful under the conditions for which OIE recommends ASFV antibody surveillance, i.e., in ASFV-endemic areas and for the detection of infections with ASFV isolates of low virulence.
Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio
2015-04-07
This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.
2017-10-01
in the baseline samples of the Scleroderma Lung Study II (SLS II). We are currently analyzing whether these serum proteins have predictive...In this project, we use the valuable samples collected in the Scleroderma Lung Study II (SLSII) clinical trial and the observational cohort, GENISOS...determine key serum protein levels and transcript signatures in whole blood and skin samples collected in the SLSII study . The identified candidate
Chaya, DR; Parija, Subhash Chandra
2014-01-01
Introduction: Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. Materials and Methods: An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Results: Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Conclusions: Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis. PMID:24754027
Chaya, Dr; Parija, Subhash Chandra
2014-01-01
Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.
Effect of storage duration on cytokine stability in human serum and plasma.
Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James
2018-06-14
Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.
Lou, Chaoyan; Guo, Dandan; Wang, Nani; Wu, Shuchao; Zhang, Peimin; Zhu, Yan
2017-06-02
An online membrane-based distillation (MBD) coupled with ion chromatography (IC) method was proposed for automatic detection of trace fluoride (F - ) in serum and urine samples. The system consisted of a sample vessel, a lab-made membrane module and an ion chromatograph. Hydrophobic polytetrafluoroethylene (PTFE) hollow fiber membrane was used in MBD which was directly performed in serum and urine samples to eliminate the matrix interferences and enrich fluoride, while enabling automation. The determination of fluoride in biological samples was carried out by IC with suppressed conductometric detection. The proposed method feasibly determined trace fluoride in serum and urine matrices with the optimized parameters, such as acid concentration, distillation temperature, and distillation time, etc. Fluoride exhibited satisfactory linearity in the range of 0.01-5.0mg/L with a correlation coefficient of 0.9992. The limit of detection (LOD, S/N=3) and limit of quantification (LOQ, S/N=10) were 0.78μg/L and 2.61μg/L, respectively. The relative standard deviations of peak area and peak height were all less than 5.15%. The developed method was validated for the determination of fluoride in serum and urine with good spiked recoveries ranging between 97.1-101.9%. This method also can be proposed as a suitable alternative for the analysis of fluoride in other complex biological samples. Copyright © 2017. Published by Elsevier B.V.
Comparative analysis of EV isolation procedures for miRNAs detection in serum samples.
Andreu, Zoraida; Rivas, Eva; Sanguino-Pascual, Aitana; Lamana, Amalia; Marazuela, Mónica; González-Alvaro, Isidoro; Sánchez-Madrid, Francisco; de la Fuente, Hortensia; Yáñez-Mó, María
2016-01-01
Extracellular vesicles (EVs) are emerging as potent non-invasive biomarkers. However, current methodologies are time consuming and difficult to translate to clinical practice. To analyse EV-encapsulated circulating miRNA, we searched for a quick, easy and economic method to enrich frozen human serum samples for EV. We compared the efficiency of several protocols and commercial kits to isolate EVs. Different methods based on precipitation, columns or filter systems were tested and compared with ultracentrifugation, which is the most classical protocol to isolate EVs. EV samples were assessed for purity and quantity by nanoparticle tracking analysis and western blot or cytometry against major EV protein markers. For biomarker validation, levels of a set of miRNAs were determined in EV fractions and compared with their levels in total serum. EVs isolated with precipitation-based methods were enriched for a subgroup of miRNAs that corresponded to miRNAs described to be encapsulated into EVs (miR-126, miR-30c and miR-143), while the detection of miR-21, miR-16-5p and miR-19a was very low compared with total serum. Our results point to precipitation using polyethylene glycol (PEG) as a suitable method for an easy and cheap enrichment of serum EVs for miRNA analyses. The overall performance of PEG was very similar, or better than other commercial precipitating reagents, in both protein and miRNA yield, but in comparison to them PEG is much cheaper. Other methods presented poorer results, mostly when assessing miRNA by qPCR analyses. Using PEG precipitation in a longitudinal study with human samples, we demonstrated that miRNA could be assessed in frozen samples up to 8 years of storage. We report a method based on a cut-off value of mean of fold EV detection versus serum that provides an estimate of the degree of encapsulation of a given miRNA.
Goudarzi, Nasser; Amirnavaee, Monavar; Arab Chamjangali, Mansour; Farsimadan, Sahar
2017-07-01
An improved microextraction method is proposed on the basis of ultrasound-assisted surfactant-enhanced emulsification and solidification of a floating organic droplet procedure combined with high performance liquid chromatography for the preconcentration and quantification of alprazolam (ALP) and chlordiazepoxide (CHL) present in a number of human serum samples. Several parameters affecting the extraction efficiency were investigated by the Plackett -Burman factorial design as the screening design. Then the response surface methodology based on the Box-Behnken design was used to optimize the effective parameters in the proposed procedure. The limits of detection for the proposed method were found to be 3.0 and 3.1 ng mL-1 for CHL and ALP, respectively. The calibration curves obtained for the method were linear in the ranges of 10.0-3,500.0 and 10.0-3,000.0 ng mL-1 for CHL and ALP, respectively, with a good determination coefficient. The recoveries of the drugs in the spiked human serum samples were above 93.0%. The developed method was successfully applied to the analysis of these studied drugs in human serum samples. The pre-treatment of the serum samples was performed using acetonitrile to remove the proteins. The proposed procedure was an accurate and reliable one for the determination and preconcentration of these drugs in blood samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Neng, Jing; Li, Yina; Driscoll, Ashley J; Wilson, William C; Johnson, Patrick A
2018-06-06
A robust immunoassay based on surface-enhanced Raman scattering (SERS) has been developed to simultaneously detect trace quantities of multiple pathogenic antigens from West Nile virus, Rift Valley fever virus, and Yersinia pestis in fetal bovine serum. Antigens were detected by capture with silica-encapsulated nanotags and magnetic nanoparticles conjugated with polyclonal antibodies. The magnetic pull-down resulted in aggregation of the immune complexes, and the silica-encapsulated nanotags provided distinct spectra corresponding to each antigen captured. The limit of detection was ∼10 pg/mL in 20% fetal bovine serum, a significant improvement over previous studies in terms of sensitivity, level of multiplexing, and medium complexity. This highly sensitive multiplex immunoassay platform provides a promising method to detect various antigens directly in crude serum samples without the tedious process of sample preparation, which is desirable for on-site diagnostic testing and real-time disease monitoring.
Curry, Patricia S; Ribble, Carl; Sears, William C; Hutchins, Wendy; Orsel, Karin; Godson, Dale; Lindsay, Robbin; Dibernardo, Antonia; Kutz, Susan J
2014-04-01
We compared Nobuto filter paper (FP) whole-blood samples to serum for detecting antibodies to seven pathogens in reindeer (Rangifer tarandus tarandus). Serum and FP samples were collected from captive reindeer in 2008-2009. Sample pairs (serum and FP eluates) were assayed in duplicate at diagnostic laboratories with the use of competitive enzyme-linked immunosorbent assays (cELISAs) for Neospora caninum and West Nile virus (WNV); indirect ELISA (iELISAs) for bovine herpesvirus type 1 (BHV-1), parainfluenza virus type 3 (PI-3), and bovine respiratory syncytial virus (BRSV); and virus neutralization (VN) for bovine viral diarrhea virus (BVDV) types I and II. Assay thresholds were evidence-based values employed by each laboratory. Comparable performance to serum was defined as FP sensitivity and specificity ≥ 80%. Filter-paper specificity estimates ranged from 92% in the cELISAs for N. caninum and WNV to 98% in the iELISAs for PI-3 and BRSV. Sensitivity was >85% for five tests (most ≥ 95%) but was insufficient (71-82%) for the PI-3 and BRSV iELISAs. Lowering the threshold for FP samples in these two ELISAs raised sensitivity to ≥ 87% and reduced specificity slightly (≥ 90% in three of the four test runs). Sample size limited the precision of some performance estimates. Based on the criteria of sensitivity and specificity ≥ 80%, and using adjusted FP thresholds for PI-3 and BRSV, FP sensitivity and specificity were comparable to serum in all seven assays. A potential limitation of FP is reduced sensitivity in tests that require undiluted serum (i.e., N. caninum cELISA and BVDV VNs). Possible toxicity to the assay cell layer in VN requires investigation. Results suggested that cELISA is superior to iELISA for detecting antibodies in FP samples from reindeer and other Rangifer tarandus subspecies. Our findings expand the potential utility of FP sampling from wildlife.
Determination of chlormequat in pig serum and sow milk by LC-MS/MS.
Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H
2007-11-01
Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.
Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.
Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen
2016-12-01
Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.
Li, Jian; Chen, Tian; Wang, Yuwei; Shi, Zhixiong; Zhou, Xianqing; Sun, Zhiwei; Wang, Dejun; Wu, Yongning
2017-02-01
Two simplified sample preparation procedures for simultaneous extraction and clean-up of tetrabromobisphenol A, α-, β-, and γ-hexabromocyclododecane and polybrominated diphenyl ethers in human serum were developed and validated. The first procedure was based on solid-phase extraction. Sample extraction, purification, and lipid removal were carried out directly on an Oasis HLB cartridge. The second procedure was a quick, easy, cheap, effective, rugged, and safe-based approach using octadecyl-modified silica particles as a sorbent. After sample extraction and cleanup, tetrabromobisphenol A/hexabromocyclododecane was separated from polybrominated diphenyl ethers by using a Si-based cartridge. Tetrabromobisphenol A and hexabromocyclododecane were then detected by high-performance liquid chromatography coupled to tandem mass spectrometry, while polybrominated diphenyl ethers were detected by gas chromatography coupled to tandem mass spectrometry. The results of the spike recovery test using fetal bovine serum showed that the average recoveries of the analytes ranged from 87.3 to 115.3% with relative standard deviations equal to or lower than 13.4 %. Limits of detection of the analytes were in the range of 0.4-19 pg/mL except for decabromodiphenyl ether. The developed method was successfully applied to routine analysis of human serum samples from occupational workers and the general population. Extremely high serum polybrominated diphenyl ethers levels up to 3.32 × 10 4 ng/g lipid weight were found in occupational workers. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gastrointestinal parasites of feral cats from Christmas Island.
Adams, P J; Elliot, A D; Algar, D; Brazell, R I
2008-01-01
To investigate the gastrointestinal parasites present in feral cats on Christmas Island, with particular interest in the protozoan parasite Toxoplasma gondii. Faecal and serum samples were collected from 28 and 25 cats respectively that were trapped as part of an ongoing eradication program being run on Christmas Island by the Department of Environment and Conservation. Faecal samples were screened microscopically for helminth and protozoan parasites. Serum samples were screened for antibodies to T gondii using a commercial indirect immunofluorescence assay (IFA) and a latex agglutination test (LAT). The most common helminth parasites detected were Toxocara cati (present in 15 of 28 faecal samples), Strongyloides sp (13/28), Aelurostrongylus abstrusus, (7/28), an unidentified capillarid (6/28) and Ancylostoma sp (4/28). Based on serology, T gondii was the most common parasite detected (protozoan or otherwise) with antibodies detected in 24 serum samples by IFA and 23 serum samples by LAT. Cats on Christmas Island harbour many of the helminth and protozoan parasites reported from feral cats elsewhere in Australia. The high seroprevalence of T gondii in these cats indicates a high level of exposure to the parasite in this environment.
Sub-tesla-field magnetization of vibrated magnetic nanoreagents for screening tumor markers
NASA Astrophysics Data System (ADS)
Chieh, Jen-Jie; Huang, Kai-Wen; Shi, Jin-Cheng
2015-02-01
Magnetic nanoreagents (MNRs), consisting of liquid solutions and magnetic nanoparticles (MNPs) coated with bioprobes, have been widely used in biomedical disciplines. For in vitro tests of serum biomarkers, numerous MNR-based magnetic immunoassay methods or schemes have been developed; however, their applications are limited. In this study, a vibrating sample magnetometer (VSM) was used for screening tumor biomarkers based on the same MNRs as those used in other immunoassay methods. The examination mechanism is that examined tumor biomarkers are typically conjugated to the bioprobes coated on MNPs to form magnetic clusters. Consequently, the sub-Tesla-field magnetization (Msub-T) of MNRs, including magnetic clusters, exceeds that of MNRs containing only separate MNPs. For human serum samples, proteins other than the targeted biomarkers induce the formation of magnetic clusters with increased Msub-T because of weak nonspecific binding. In this study, this interference problem was suppressed by the vibration condition in the VSM and analysis. Based on a referenced Msub-T,0 value defined by the average Msub-T value of a normal person's serum samples, including general proteins and few tumor biomarkers, the difference ΔMsub-T between the measured Msub-T and the reference Msub-T,0 determined the expression of only target tumor biomarkers in the tested serum samples. By using common MNRs with an alpha-fetoprotein-antibody coating, this study demonstrated that a current VSM can perform clinical screening of hepatocellular carcinoma.
NASA Astrophysics Data System (ADS)
Lin, Duo; Feng, Shangyuan; Pan, Jianji; Chen, Yanping; Lin, Juqiang; Sun, Liqing; Chen, Rong
2011-11-01
Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopic technique that is capable of probing the biomolecular changes associated with diseased transformation. The objective of our study was to explore gold nanoparticle based SERS to obtain blood serum biochemical information for non-invasive colorectal cancer detection. SERS measurements were performed on two groups of blood serum samples: one group from patients (n = 38) with pathologically confirmed colorectal cancer and the other group from healthy volunteers (control subjects, n = 45). Tentative assignments of the Raman bands in the measured SERS spectra suggested interesting cancer specific biomolecular changes, including an increase in the relative amounts of nucleic acid, a decrease in the percentage of saccharide and proteins contents in the blood serum of colorectal cancer patients as compared to that of healthy subjects. Principal component analysis (PCA) of the measured SERS spectra separated the spectral features of the two groups into two distinct clusters with little overlaps. Linear discriminate analysis (LDA) based on the PCA generated features differentiated the nasopharyngeal cancer SERS spectra from normal SERS spectra with high sensitivity (97.4%) and specificity (100%). The results from this exploratory study demonstrated that gold nanoparticle based SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of colorectal cancers.
NASA Astrophysics Data System (ADS)
Lin, Duo; Feng, Shangyuan; Pan, Jianji; Chen, Yanping; Lin, Juqiang; Sun, Liqing; Chen, Rong
2012-03-01
Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopic technique that is capable of probing the biomolecular changes associated with diseased transformation. The objective of our study was to explore gold nanoparticle based SERS to obtain blood serum biochemical information for non-invasive colorectal cancer detection. SERS measurements were performed on two groups of blood serum samples: one group from patients (n = 38) with pathologically confirmed colorectal cancer and the other group from healthy volunteers (control subjects, n = 45). Tentative assignments of the Raman bands in the measured SERS spectra suggested interesting cancer specific biomolecular changes, including an increase in the relative amounts of nucleic acid, a decrease in the percentage of saccharide and proteins contents in the blood serum of colorectal cancer patients as compared to that of healthy subjects. Principal component analysis (PCA) of the measured SERS spectra separated the spectral features of the two groups into two distinct clusters with little overlaps. Linear discriminate analysis (LDA) based on the PCA generated features differentiated the nasopharyngeal cancer SERS spectra from normal SERS spectra with high sensitivity (97.4%) and specificity (100%). The results from this exploratory study demonstrated that gold nanoparticle based SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of colorectal cancers.
Leng, Jiapeng; Zhu, Dong; Wu, Duojiao; Zhu, Tongyu; Zhao, Ningwei; Guo, Yinlong
2012-11-15
Peptidomics analysis of human serum is challenging due to the low abundance of serum peptides and interference from the complex matrix. This study analyzed the differentially expressed (DE) low molecular weight peptides in human serum integrating a DMPITC-based N-terminal isotope labeling technique with nano-liquid chromatography and matrix-assisted laser desorption/ionization mass spectrometry (nano-LC/MALDI-MS). The workflow introduced a [d(6)]-4,6-dimethoxypyrimidine-2-isothiocyanate (DMPITC)-labeled mixture of aliquots from test samples as the internal standard. The spiked [d(0)]-DMPITC-labeled samples were separated by nano-LC then spotted on the MALDI target. Both quantitative and qualitative studies for serum peptides were achieved based on the isotope-labeled peaks. The DMPITC labeling technique combined with nano-LC/MALDI-MS not only minimized the errors in peptide quantitation, but also allowed convenient recognition of the labeled peptides due to the 6 Da mass difference. The data showed that the entire research procedure as well as the subsequent data analysis method were effective, reproducible, and sensitive for the analysis of DE serum peptides. This study successfully established a research model for DE serum peptides using DMPITC-based N-terminal isotope labeling and nano-LC/MALDI-MS. Application of the DMPITC-based N-terminal labeling technique is expected to provide a promising tool for the investigation of peptides in vivo, especially for the analysis of DE peptides under different biological conditions. Copyright © 2012 John Wiley & Sons, Ltd.
Li, Xiao; Tan, Jie; Yu, Jiekai; Feng, Jiandong; Pan, Aiwu; Zheng, Shu; Wu, Jianmin
2014-11-07
Small peptides in serum are potential biomarkers for the diagnosis of cancer and other diseases. The identification of peptide biomarkers in human plasma/serum has become an area of high interest in medical research. However, the direct analysis of peptides in serum samples using mass spectrometry is challenging due to the low concentration of peptides and the high abundance of high-molecular-weight proteins in serum, the latter of which causes severe signal suppression. Herein, we reported that porous semiconductor-noble metal hybrid nanostructures can both eliminate the interference from large proteins in serum samples and significantly enhance the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) yields of peptides captured on the nanostructure. Serum peptide fingerprints with high fidelity can be acquired rapidly, and successful discrimination of colorectal cancer patients based on peptide fingerprints is demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.
O'Neal, Wanda K; Anderson, Wayne; Basta, Patricia V; Carretta, Elizabeth E; Doerschuk, Claire M; Barr, R Graham; Bleecker, Eugene R; Christenson, Stephanie A; Curtis, Jeffrey L; Han, Meilan K; Hansel, Nadia N; Kanner, Richard E; Kleerup, Eric C; Martinez, Fernando J; Miller, Bruce E; Peters, Stephen P; Rennard, Stephen I; Scholand, Mary Beth; Tal-Singer, Ruth; Woodruff, Prescott G; Couper, David J; Davis, Sonia M
2014-01-08
As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100). 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers.
2014-01-01
Background As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100™). Methods 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. Results 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. Conclusions There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers. PMID:24397870
Wang, Michael Z; Howard, Brandon; Campa, Michael J; Patz, Edward F; Fitzgerald, Michael C
2003-09-01
Direct matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of human serum yielded ion signals from only a fraction of the total number of peptides and proteins expected to be in the sample. We increased the number of peptide and protein ion signals observed in the MALDI-TOF mass spectra analysis of human serum by using a prefractionation protocol based on liquid phase isoelectric focusing electrophoresis. This pre-fractionation technique facilitated the MALDI-TOF MS detection of as many as 262 different peptide and protein ion signals from human serum. The results obtained from three replicate fractionation experiments on the same serum sample indicated that 148 different peptide and protein ion signals were reproducibly detected using our isoelectric focusing and MALDI-TOF MS protocol.
Pires, Cherrine K.; Martelli, Patrícia B.; Lima, José L. F. C.; Saraiva, Maria Lúcia M. F. S.
2003-01-01
An automatic flow procedure based on multicommutation dedicated for the determination of glucose in animal blood serum using glucose oxidase with chemiluminescence detection is described. The flow manifold consisted of a set of three-way solenoid valves assembled to implement multicommutation. A microcomputer furnished with an electronic interface and software written in Quick BASIC 4.5 controlled the manifold and performed data acquisition. Glucose oxidase was immobilized on porous silica beads (glass aminopropyl) and packed in a minicolumn (15 × 5 mm). The procedure was based on the enzymatic degradation of glucose, producing hydrogen peroxide, which oxidized luminol in the presence of hexacyanoferrate(III), causing the chemiluminescence. The system was tested by analysing a set of serum animal samples without previous treatment. Results were in agreement with those obtained with the conventional method (LABTEST Kit) at the 95% confidence level. The detection limit and variation coefficient were estimated as 12.0 mg l−1 (99.7% confidence level) and 3.5% (n = 20), respectively. The sampling rate was about 60 determinations h−1 with sample concentrations ranging from 50 to 600 mg l−1 glucose. The consumptions of serum sample, hexacyanoferrate(III) and luminol were 46 μl, 10.0 mg and 0.2 mg/determination, respectively. PMID:18924619
Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L
2014-12-01
The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.
Salgado, Miguel; Kruze, Juan; Collins, Michael T
2007-01-01
Fecal culture has been the primary method used to diagnose paratuberculosis in goats. It is laborious, slow, and expensive. Validation of enzyme-linked immunosorbent assays (ELISAs) on milk samples could make paratuberculosis testing more widely available for goat farmers. The aim of this study was to determine the accuracy of serum and milk ELISAs for paratuberculosis, relative to fecal culture, in Chilean dairy goats. Eight dairy goat herds were selected. Feces, blood, and milk samples were collected from all female goats >2 years old. Fecal samples were cultured using Herrold egg yolk medium with mycobactin J and antibiotics. Serum and milk samples were tested using a commercial ELISA kit for Mycobacterium avium subsp. paratuberculosis antibody detection. A total of 383 goats were tested by ELISA and fecal culture. The sensitivity of ELISA on serum and milk relative to fecal culture was 74.3% (95% CI: 59.8-88.8) and 60% (95% CI: 43.8-76.2), respectively. The corresponding values for ELISA specificity based on the percentage of non- M. avium subsp. paratuberculosis-infected goats testing ELISA-negative were 98.6% (95% CI: 96.6-100) and 99.3% (95% CI: 97.9-100) on serum and milk, respectively. Proportions of positive results for serum and fecal samples were significantly different, whereas the proportions of positive results for milk and fecal samples were not significantly different. The milk ELISA had a moderate level of agreement with fecal culture results (Kappa = 0.57). The paratuberculosis ELISA on goat milk samples may be a cost-effective, accurate alternative to fecal culture.
Raj, G Dhinakar; Thiagarajan, V; Nachimuthu, K
2007-09-01
A simple, user-friendly, and rapid method to detect the presence of antibodies to egg drop syndrome 76 (EDS) virus in chicken sera based on an immunofiltration (flow-through) test was developed. Purified EDS virus antigen was coated onto nitrocellulose membranes housed in a plastic module with layers of absorbent filter pads underneath. Following addition of serum to be tested and washing, monoclonal antibodies or polyclonal serum to chicken immunoglobulin G (IgG) was used as a bridge antibody to mediate binding between EDS virus-specific IgG and protein A gold conjugate. The appearance of a pink dot indicated the presence of antibodies to EDS virus in the sample tested. The results could be obtained within 5-10 min. The developed immunofiltration test could detect antibodies in the sera of experimentally vaccinated chickens from 2 wk postvaccination. With field sera samples, this test was positive in samples having hemagglutination inhibition titers of 8 and above. This test has the potential to be used as a field-based kit to assess seroconversion in EDS-vaccinated flocks.
Tan, Zhijing; Yin, Haidi; Nie, Song; Lin, Zhenxin; Zhu, Jianhui; Ruffin, Mack T; Anderson, Michelle A; Simeone, Diane M; Lubman, David M
2015-04-03
Glycosylation has significant effects on protein function and cell metastasis, which are important in cancer progression. It is of great interest to identify site-specific glycosylation in search of potential cancer biomarkers. However, the abundance of glycopeptides is low compared to that of nonglycopeptides after trypsin digestion of serum samples, and the mass spectrometric signals of glycopeptides are often masked by coeluting nonglycopeptides due to low ionization efficiency. Selective enrichment of glycopeptides from complex serum samples is essential for mass spectrometry (MS)-based analysis. Herein, a strategy has been optimized using LCA enrichment to improve the identification of core-fucosylation (CF) sites in serum of pancreatic cancer patients. The optimized strategy was then applied to analyze CF glycopeptide sites in 13 sets of serum samples from pancreatic cancer, chronic pancreatitis, healthy controls, and a standard reference. In total, 630 core-fucosylation sites were identified from 322 CF proteins in pancreatic cancer patient serum using an Orbitrap Elite mass spectrometer. Further data analysis revealed that 8 CF peptides exhibited a significant difference between pancreatic cancer and other controls, which may be potential diagnostic biomarkers for pancreatic cancer.
Pedrotti Moreira, Fernanda; Borges, Cristiane Jackson; Wiener, Carolina David; da Silva, Paula Moraes; Portela, Luis Valmor; Lara, Diogo R; da Silva, Ricardo Azevedo; de Mattos Souza, Luciano Dias; Jansen, Karen; Oses, Jean Pierre
2018-04-01
Major depressive disorders (MDD) and suicide are significant public health concerns. Recent studies have been demonstrated that alterations in Brain Derived Neurotrophic Factor (BDNF) can be associated with this psychiatric disorders, MDD and suicide. Thus, the aim of this study was to evaluate differences in serum levels in individuals with MDD and with or without suicide attempt (SA), from a population-based sample. This was a paired cross-sectional study nested in a population-based study. The psychopathology screen was performed with the Mini-International Neuropsychiatric Interview (MINI). The total population of the sample consisted of 147 subjects distributed in three groups: 49 healthy controls, 49 subjects with MDD and 49 subjects with MDD and SA (MDD + SA). The BDNF serum levels were significantly reduced in subjects with MDD and MDD + SA compared to the healthy controls. However, there were no significant differences between the MDD and MDD + SA groups with respect to BDNF serum levels. These results suggest that SA did not interfere in the serum levels of BDNF, indicating that this neurotrophin may be related to the diagnosis of MDD and not to suicide attempt. Copyright © 2017 Elsevier B.V. All rights reserved.
Selective Distance-Based K+ Quantification on Paper-Based Microfluidics.
Gerold, Chase T; Bakker, Eric; Henry, Charles S
2018-04-03
In this study, paper-based microfluidic devices (μPADs) capable of K + quantification in aqueous samples, as well as in human serum, using both colorimetric and distance-based methods are described. A lipophilic phase containing potassium ionophore I (valinomycin) was utilized to achieve highly selective quantification of K + in the presence of Na + , Li + , and Mg 2+ ions. Successful addition of a suspended lipophilic phase to a wax printed paper-based device is described and offers a solution to current approaches that rely on organic solvents, which damage wax barriers. The approach provides an avenue for future alkali/alkaline quantification utilizing μPADs. Colorimetric spot tests allowed for K + quantification from 0.1-5.0 mM using only 3.00 μL of sample solution. Selective distance-based quantification required small sample volumes (6.00 μL) and gave responses sensitive enough to distinguish between 1.0 and 2.5 mM of sample K + . μPADs using distance-based methods were also capable of differentiating between 4.3 and 6.9 mM K + in human serum samples. Distance-based methods required no digital analysis, electronic hardware, or pumps; any steps required for quantification could be carried out using the naked eye.
Isaza, Ramiro; Wiedner, Ellen; Hiser, Sarah; Cray, Carolyn
2014-09-01
Acute phase protein (APP) immunoassays and serum protein electrophoresis (SPEP) are assays for evaluating the inflammatory response and have use as diagnostic tools in a variety of species. Acute phase proteins are markers of inflammation that are highly conserved across different species while SPEP separates and quantifies serum protein fractions based on their physical properties. In the current study, serum samples from 35 clinically healthy Asian elephants (Elephas maximus) were analyzed using automated assays for C-reactive protein, serum amyloid A, and haptoglobin and SPEP. Robust methods were used to generate reference intervals for the APPs: C-reactive protein (1.3-12.8 mg/l), serum amyloid A (0-47.5 mg/l), and haptoglobin (0-1.10 mg/ml). In addition, SPEP was performed on these samples to establish reference intervals for each protein fraction. A combination of APPs and SPEP measurements are valuable adjunctive diagnostic tools in elephant health care. © 2014 The Author(s).
Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin
2013-06-01
Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.
Partition of environmental chemicals between maternal and fetal blood and tissues.
Needham, Larry L; Grandjean, Philippe; Heinzow, Birger; Jørgensen, Poul J; Nielsen, Flemming; Patterson, Donald G; Sjödin, Andreas; Turner, Wayman E; Weihe, Pal
2011-02-01
Passage of environmental chemicals across the placenta has important toxicological consequences, as well as for choosing samples for analysis and for interpreting the results. To obtain systematic data, we collected in 2000 maternal and cord blood, cord tissue, placenta, and milk in connection with births in the Faroe Islands, where exposures to marine contaminants is increased. In 15 sample sets, we measured a total of 87 environmental chemicals, almost all of which were detected both in maternal and fetal tissues. The maternal serum lipid-based concentrations of organohalogen compounds averaged 1.7 times those of cord serum, 2.8 times those of cord tissue and placenta, and 0.7 those of milk. For organohalogen compounds detectable in all matrices, a high degree of correlation between concentrations in maternal serum and the other tissues investigated was generally observed (r(2) > 0.5). Greater degree of chlorination resulted in lower transfer from maternal serum into milk. Concentrations of pentachlorbenzene, γ-hexachlorocyclohexane, and several polychlorinated biphenyl congeners with low chlorination were higher in fetal samples and showed poor correlation with maternal levels. Perfluorinated compounds occurred in lower concentrations in cord serum than in maternal serum. Cadmium, lead, mercury, and selenium were all detected in fetal samples, but only mercury showed close correlations among concentrations in different matrices. Although the environmental chemicals examined pass through the placenta and are excreted into milk, partitions between maternal and fetal samples are not uniform.
van der Loos, Matthijs J H M; Haring, Robin; Rietveld, Cornelius A; Baumeister, Sebastian E; Groenen, Patrick J F; Hofman, Albert; de Jong, Frank H; Koellinger, Philipp D; Kohlmann, Thomas; Nauck, Matthias A; Rivadeneira, Fernando; Uitterlinden, André G; van Rooij, Frank J A; Wallaschofski, Henri; Thurik, A Roy
2013-07-02
Previous research has suggested a positive association between testosterone (T) and entrepreneurial behavior in males. However, this evidence was found in a study with a small sample size and has not been replicated. In the present study, we aimed to verify this association using two large, independent, population-based samples of males. We tested the association of T with entrepreneurial behavior, operationalized as self-employment, using data from the Rotterdam Study (N=587) and the Study of Health in Pomerania (N=1697). Total testosterone (TT) and sex hormone-binding globulin (SHBG) were measured in the serum. Free testosterone (FT), non-SHBG-bound T (non-SHBG-T), and the TT/SHBG ratio were calculated and used as measures of bioactive serum T, in addition to TT adjusted for SHBG. Using logistic regression models, we found no significant associations between any of the serum T measures and self-employment in either of the samples. To our knowledge, this is the first large-scale study on the relationship between serum T and entrepreneurial behavior. Copyright © 2013 Elsevier Inc. All rights reserved.
Mohammadpour, Niloofar; Saki, Jasem; Rafiei, Abdollah; Khodadadi, Ali; Tavalla, Mehdi; Cheraghian, Bahman
2016-10-01
Toxoplasma gondii is one of the most common causes of latent infections in humans worldwide. Detecting anti- Toxoplasma antibodies in serum using serological tests is a common method to diagnose toxoplasmosis. In the present study, an indigenous ELISA kit was prepared using tachyzoites from the RH strain of T. gondii , and its sensitivity and specificity were compared with those of commercial kits. To produce antigens, 0.02 mL of locally isolated T. gondii RH strain parasites along with 10 9 tachyzoites were injected into the peritoneal cavities of 50 laboratory mice (BALB/C). Parasites were collected after 4 days. After filtering and washing, the concentration of protein in sonicated tachyzoites was calculated using the Lowry protein assay. The dilution of antigen, serum and alkaline phosphatase conjugate was assessed in designing an indigenous ELISA method; then ELISA was performed based on these dilutions, and its sensitivity was determined using 200 serum samples. In addition, the specificity of the assay was evaluated using 40 serum samples from patients with tuberculosis, leukemia or hydatid cyst. Indigenous ELISA was used to examine 100 serum samples containing anti- T. gondii IgG, with a sensitivity of 98% (commercial kits: 100%). Another 100 serum samples containing anti- T. gondii IgM were also tested, with a sensitivity of 99% (commercial kits: 100%). When 40 serum samples from patients with leukemia, hydatid cyst or tuberculosis were examined using anti- T. gondii IgG, the specificity was 100%, identical to commercial kits. However, the specificity of a similar test with anti- T. gondii IgM was just 28.6% for serum samples from leukemia patients, 21.4% for hydatid cyst and 16.7% for tuberculosis. We found that purified locally isolated soluble crude antigens of the RH strain of T. gondii from the peritoneal cavity of mice may be one of the most promising antigens for detection of human toxoplasmosis in routine screening.
Screening the low molecular weight fraction of human serum using ATR-IR spectroscopy.
Bonnier, Franck; Brachet, Guillaume; Duong, Romain; Sojinrin, Tobiloba; Respaud, Renaud; Aubrey, Nicolas; Baker, Matthew J; Byrne, Hugh J; Chourpa, Igor
2016-10-01
Vibrational spectroscopic techniques can detect small variations in molecular content, linked with disease, showing promise for screening and early diagnosis. Biological fluids, particularly blood serum, are potentially valuable for diagnosis purposes. The so-called Low Molecular Weight Fraction (LMWF) contains the associated peptidome and metabolome and has been identified as potentially the most relevant molecular population for disease-associated biomarker research. Although vibrational spectroscopy can deliver a specific chemical fingerprint of the samples, the High Molecular Weight Fraction (HMWF), composed of the most abundant serum proteins, strongly dominates the response and ultimately makes the detection of minor spectral variations a challenging task. Spectroscopic detection of potential serum biomarkers present at relatively low concentrations can be improved using pre-analytical depletion of the HMWF. In the present study, human serum fractionation by centrifugal filtration was used prior to analysis by Attenuated Total Reflection infrared spectroscopy. Using a model sample based on glycine spiked serum, it is demonstrated that the screening of the LMWF can be applied to quantify blinded concentrations up to 50 times lower. Moreover, the approach is easily transferable to different bodily fluids which would support the development of more efficient and suitable clinical protocols exploring vibrational spectroscopy based ex-vivo diagnostic tools. Revealing serum LMWF for spectral serological diagnostic applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.
2012-08-03
Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the developmentmore » of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.« less
Gutiérrez, Orlando M; Katz, Ronit; Peralta, Carmen A; de Boer, Ian H; Siscovick, David; Wolf, Myles; Diez Roux, Ana; Kestenbaum, Bryan; Nettleton, Jennifer A; Ix, Joachim H
2012-09-01
Higher serum phosphorus concentrations are associated with cardiovascular disease events and mortality. Low socioeconomic status is linked with higher serum phosphorus concentration, but the reasons are unclear. Poor individuals disproportionately consume inexpensive processed foods commonly enriched with phosphorus-based food preservatives. Accordingly, we hypothesized that excess intake of these foods accounts for a relationship between lower socioeconomic status and higher serum phosphorus concentration. Cross-sectional analysis. We examined a random cohort of 2,664 participants with available phosphorus measurements in the Multi-Ethnic Study of Atherosclerosis, a community-based sample of individuals free of clinically apparent cardiovascular disease from across the United States. Socioeconomic status, the intake of foods commonly enriched with phosphorus-based food additives (processed meats, sodas), and frequency of fast-food consumption. Fasting morning serum phosphorus concentrations. In unadjusted analyses, lower income and lower educational achievement categories were associated with modestly higher serum phosphorus concentration (by 0.02 to 0.10 mg/dL, P < .05 for all). These associations were attenuated in models adjusted for demographic and clinical factors, almost entirely due to adjustment for female gender. In multivariable-adjusted analyses, there were no statistically significant associations of processed meat intake or frequency of fast-food consumption with serum phosphorus. In contrast, each serving per day higher soda intake was associated with 0.02 mg/dL lower serum phosphorus concentration (95% confidence interval, -0.04, -0.01). Greater intake of foods commonly enriched with phosphorus additives was not associated with higher serum phosphorus concentration in a community-living sample with largely preserved kidney function. These results suggest that excess intake of processed and fast foods may not impact fasting serum phosphorus concentrations among individuals without kidney disease. Copyright © 2012 National Kidney Foundation, Inc. All rights reserved.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-07
To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-01
AIM: To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). METHODS: Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn’s disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student’s t test (α = 0.05). RESULTS: The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. CONCLUSION: NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission. PMID:24415869
Parathyroid hormone related protein concentration in human serum and CSF correlates with age.
Kushnir, Mark M; Peterson, Lisa K; Strathmann, Frederick G
2018-02-01
Parathyroid Hormone-Related Protein (PTHrP) is involved in intracellular calcium (Ca) regulation, and has been demonstrated to participate in regulation of Ca in brain cells, activation of neurons, and modulation of pain. However, there are conflicting reports regarding the presence of PTHrP in CSF. PTHrP and Ca were quantified in paired CSF and serum samples using mass spectrometry-based methods. Associations between PTHrP and Ca concentrations with age, sex and concentrations of nine CSF diagnostic markers in a set of 140 paired serum and CSF patient samples were evaluated. The observed median PTHrP concentration in CSF was 51 times higher than in serum; the median concentration of Ca in CSF was 1.8 times lower than in serum. We observed positive correlation between concentrations of PTHrP in CSF and serum (p=0.013). Distribution of PTHrP concentrations in serum was associated with age (p=0.0068) and the concentrations were higher in women. In samples with serum calcium concentrations within the reference intervals (n=118), central 95% distribution of concentrations for Ca-CSF, PTHrP-serum and PTHrP-CSF were 5.4 (4.5-6.1) mg/dL, 1.2 (0.5-2.5) pmol/L, 62 (22-125) pmol/L, respectively. Our data demonstrate that PTHrP is a normal constituent of human CSF with median concentrations 51 fold higher than in serum. Elevated serum PTHrP concentrations were positively correlated with age and significantly higher in women. Our data suggest that CSF could be a significant source of circulating PTHrP. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Gutiérrez, Orlando M.; Katz, Ronit; Peralta, Carmen A.; de Boer, Ian H.; Siscovick, David; Wolf, Myles; Roux, Ana Diez; Kestenbaum, Bryan; Nettleton, Jennifer A.; Ix, Joachim H.
2011-01-01
Objective Higher serum phosphorus concentrations are associated with cardiovascular disease events and mortality. Low socioeconomic status is linked with higher serum phosphorus, but the reasons are unclear. Poor individuals disproportionately consume inexpensive processed foods commonly enriched with phosphorus-based food preservatives. Accordingly, we hypothesized that excess intake of these foods accounts for a relationship between lower socioeconomic status and higher serum phosphorus. Design Cross-sectional analysis. Setting and Participants We examined a random cohort of 2,664 participants with available phosphorus measurements in the Multi-Ethnic Study of Atherosclerosis, a community-based sample of individuals free of clinically apparent cardiovascular disease from across the United States. Predictor Variables Socioeconomic status, the intake of foods commonly enriched with phosphorus additives (processed meats, sodas) and frequency of fast food consumption. Outcomes Fasting morning serum phosphorus concentrations. Results In unadjusted analyses, lower income and lower educational achievement categories were associated with modestly higher serum phosphorus (by 0.02 to 0.10 mg/dL, P < 0.05 for all). These associations were attenuated in models adjusted for demographic and clinical factors, almost entirely due to adjustment for female gender. There were no statistically significant associations of processed meat intake or frequency of fast-food consumption with serum phosphorus in multivariable-adjusted analyses. In contrast, each serving per day higher soda intake was associated with 0.02 mg/dl lower serum phosphorus (95% confidence interval, −0.04, −0.01). Conclusions Greater intake of foods commonly enriched with phosphorus additives was not associated with higher serum phosphorus in a community-living sample with largely preserved kidney function. These results suggest that excess intake of processed and fast foods may not impact fasting serum phosphorus concentrations among individuals without kidney disease. PMID:22217539
Twenty-four cases of imported zika virus infections diagnosed by molecular methods.
Alejo-Cancho, Izaskun; Torner, Nuria; Oliveira, Inés; Martínez, Ana; Muñoz, José; Jane, Mireia; Gascón, Joaquim; Requena-Méndez, Ana; Vilella, Anna; Marcos, M Ángeles; Pinazo, María Jesús; Gonzalo, Verónica; Rodriguez, Natalia; Martínez, Miguel J
2016-10-01
Zika virus is an emerging flavivirus widely spreading through Latin America. Molecular diagnosis of the infection can be performed using serum, urine and saliva samples, although a well-defined diagnostic algorithm is not yet established. We describe a series of 24 cases of imported zika virus infection into Catalonia (northeastern Spain). Based on our findings, testing of paired serum and urine samples is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.
Sipa1l1 is an early biomarker of liver fibrosis in CCl4-treated rats
Marfà, Santiago; Morales-Ruiz, Manuel; Oró, Denise; Ribera, Jordi; Fernández-Varo, Guillermo; Jiménez, Wladimiro
2016-01-01
ABSTRACT At present, several procedures are used for staging liver fibrosis. However, these methods may involve clinical complications and/or present diagnostic uncertainty mainly in the early stages of the disease. Thus, this study was designed to unveil new non-invasive biomarkers of liver fibrosis in an in vivo model of fibrosis/cirrhosis induction by CCl4 inhalation by using a label-free quantitative LC-MS/MS approach. We analyzed 94 serum samples from adult Wistar rats with different degrees of liver fibrosis and 36 control rats. Firstly, serum samples from 18 CCl4-treated rats were clustered into three different groups according to the severity of hepatic and the serum proteome was characterized by label-free LC-MS/MS. Furthermore, three different pooled serum samples obtained from 16 control Wistar rats were also analyzed. Based on the proteomic data obtained, we performed a multivariate analysis which displayed three main cell signaling pathways altered in fibrosis. In cirrhosis, more biological imbalances were detected as well as multi-organ alterations. In addition, hemopexin and signal-induced proliferation-associated 1 like 1 (SIPA1L1) were selected as potential serum markers of liver fibrogenesis among all the analyzed proteins. The results were validated by ELISA in an independent group of 76 fibrotic/cirrhotic rats and 20 controls which confirmed SIPA1L1 as a potential non-invasive biomarker of liver fibrosis. In particular, SIPA1L1 showed a clear diminution in serum samples from fibrotic/cirrhotic rats and a great accuracy at identifying early fibrotic stages. In conclusion, the proteomic analysis of serum samples from CCl4-treated rats has enabled the identification of SIPA1L1 as a non-invasive marker of early liver fibrosis. PMID:27230648
Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio
2013-01-01
A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700
Findeisen, Peter; Peccerella, Teresa; Post, Stefan; Wenz, Frederik; Neumaier, Michael
2008-04-01
Serum is a difficult matrix for the identification of biomarkers by mass spectrometry (MS). This is due to high-abundance proteins and their complex processing by a multitude of endogenous proteases making rigorous standardisation difficult. Here, we have investigated the use of defined exogenous reporter peptides as substrates for disease-specific proteases with respect to improved standardisation and disease classification accuracy. A recombinant N-terminal fragment of the Adenomatous Polyposis Coli (APC) protein was digested with trypsin to yield a peptide mixture for subsequent Reporter Peptide Spiking (RPS) of serum. Different preanalytical handling of serum samples was simulated by storage of serum samples for up to 6 h at ambient temperature, followed by RPS, further incubation under standardised conditions and testing for stability of protease-generated MS profiles. To demonstrate the superior classification accuracy achieved by RPS, a pilot profiling experiment was performed using serum specimens from pancreatic cancer patients (n = 50) and healthy controls (n = 50). After RPS six different peak categories could be defined, two of which (categories C and D) are modulated by endogenous proteases. These latter are relevant for improved classification accuracy as shown by enhanced disease-specific classification from 78% to 87% in unspiked and spiked samples, respectively. Peaks of these categories presented with unchanged signal intensities regardless of preanalytical conditions. The use of RPS generally improved the signal intensities of protease-generated peptide peaks. RPS circumvents preanalytical variabilities and improves classification accuracies. Our approach will be helpful to introduce MS-based proteomic profiling into routine laboratory testing.
Alemtuzumab: validation of a sensitive and simple enzyme-linked immunosorbent assay.
Jilani, Iman; Keating, Michael; Giles, Francis J; O'Brien, Susan; Kantarjian, Hagop M; Albitar, Maher
2004-12-01
Alemtuzumab (MabCampath) is a humanized rat monoclonal antibody that targets the CD52 antigen. It has been approved for the treatment of patients with resistant chronic lymphocytic leukaemia (CLL). Measuring plasma/serum levels of alemtuzumab is important for optimizing the dosing and scheduling of therapy; however, current assays in serum or plasma, based on the capture of alemtuzumab using CD52, are complicated and difficult to adapt for high throughput testing. We developed a simple sandwich enzyme-linked immunosorbent assay (ELISA) to measure alemtuzumab that takes advantage of the remaining rat sequence in alemtuzumab. Using specific anti-rat immunoglobulin (Ig) antibodies (absorbed against human Ig), alemtuzumab levels were measured in the serum and plasma of patients treated with alemtuzumab. Levels were similar between plasma and serum samples, in fresh samples and samples stored at 4 degrees C for 24 h, but were significantly lower in samples stored at room temperature for 24h. The assay was successfully used to determine serum alemtuzumab pre- and post-treatment. This assay is simple and adaptable for high throughput testing, with a limit of detection of 0.05 microg/ml and a coefficient of variation of +/-12.5%. No false positivity was observed in >200 samples tested. This validated assay should help optimize the dosing and scheduling of alemtuzumab therapy. The underlying principles are also applicable to the measurement of other humanized antibodies using an appropriate anti-Ig.
Direct, Label-Free, and Rapid Transistor-Based Immunodetection in Whole Serum.
Gutiérrez-Sanz, Óscar; Andoy, Nesha M; Filipiak, Marcin S; Haustein, Natalie; Tarasov, Alexey
2017-09-22
Transistor-based biosensors fulfill many requirements posed upon transducers for future point-of-care diagnostic devices such as scalable fabrication and label-free and real-time quantification of chemical and biological species with high sensitivity. However, the short Debye screening length in physiological samples (<1 nm) has been a major drawback so far, preventing direct measurements in serum. In this work, we demonstrate how tailoring the sensing surface with short specific biological receptors and a polymer polyethylene glycol (PEG) can strongly enhance the sensor response. In addition, the sensor performance can be dramatically improved if the measurements are performed at elevated temperatures (37 °C instead of 21 °C). With this novel approach, highly sensitive and selective detection of a representative immunosensing parameter-human thyroid-stimulating hormone-is shown over a wide measuring range with subpicomolar detection limits in whole serum. To the best of our knowledge, this is the first demonstration of direct immunodetection in whole serum using transistor-based biosensors, without the need for sample pretreatment, labeling, or washing steps. The presented sensor is low-cost, can be easily integrated into portable diagnostics devices, and offers a competitive performance compared to state-of-the-art central laboratory analyzers.
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Wei-Jun; Leach, Robin J.; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srivastava, Sudhir; Rodland, Karin D.; Camp, David G.
2012-01-01
Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. PMID:22846433
Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio
2017-02-01
Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.
Elkhair, Nawal M; Hartmann, Helmut
2010-01-01
The identification of the reference values of Stewart variables and the changes in the acid-base status of the blood and urine in relation to the age after acid-load were studied in desert species of camels. 14 healthy young camels (age: 3-5 months) and 22 adult camels (age: 5-8 years) were used to provide the reference and percentile ranges of the Stewart variables. In the experiments, 24 healthy young camels (age: < 3-5 months) were infused with 5M NH4Cl solution (dose: 1.0 ml/kg) through a permanent intravenous catheter. Venous blood and urine samples were collected before infusion (0 hours). After the start of infusion, venous blood samples were collected at 2, 4, 6, 8 and 24 hours, and urine samples were collected at 8, 24 and 48 hours. Blood and urine samples were used for the determination of the various acid-base parameters, including the non-respiratory Stewart variables. The reference range of serum-[strong ion difference = SID3] was 39-52 mmol/l for all age groups. The reference values of serum-[acid total = A-] were between 10-17 mmol/l for all age groups. Serum-[Atotprotein] and -[Atot-albumin] showed a reference range of 19-24 mmol/I and 20-28 mmol/l, respectively. By 2-8 hours after the NH4Cl-load, the Stewart variables (serum-[SID3] and serum-[A(tot-protein)]) decreased significantly, and as a consequence, the blood pH decreased. Generally, the loaded young camels showed a transient moderate hyperchloraemic acidosis with a slight hypoproteinaemic alkalosis. These malfunctions were accompanied by increased renal fractional excretion of chloride and sodium and decreased urine pH. The identified reference values of the Stewart variables can be used for the clinical diagnosis of acid-base disturbances in camels. With the assistance of the non-respiratory Stewart variables ([SID3] and [Atot]), we can detect the determining influence of strong electrolytes (Na+, K+ and Cl-) and weak acids (proteins, Pi) on the physiological and pathological acid-base status of the animals.
Kiska, D L; Orkiszewski, D R; Howell, D; Gilligan, P H
1994-01-01
We evaluated the performance of CRYPTO-LEX (Trinity Laboratories, Inc., Raleigh, N. C.), a new mouse immunoglobulin M monoclonal antibody latex agglutination reagent which reacts with the capsular polysaccharide of the four serogroups of Cryptococcus neoformans. This test was compared with CALAS (Meridian Diagnostics, Cincinnati, Ohio) for the ability to detect cryptococcal antigen in serum and cerebrospinal fluid (CSF). A total of 580 clinical specimens (327 serum and 253 CSF samples), primarily from human immunodeficiency virus-infected patients, were tested in this study. Sixty-seven specimens (44 serum and 23 CSF samples) were positive for cryptococcal antigen with both tests, and 511 (282 serum and 229 CSF samples) were negative. The two latex reagents agreed for 326 of 327 serum specimens (44 positives and 282 negatives). One serum specimen with a titer of 1:2 was CALAS positive but CRYPTO-LEX negative. The titer correlation coefficient for the two tests was 0.884 when two highly discordant serum specimens were eliminated from analysis of the data. The two latex tests agreed for 252 of 253 CSF specimens (23 positives and 229 negatives). One specimen with a titer of 1:2 was positive with CALAS and negative by CRYPTO-LEX. The correlation coefficient of the two tests for CSF titers was 0.886. The sensitivity and specificity of CRYPTO-LEX were 97 and 100%, respectively, with a 99.6% correlation with CALAS. These data show that the performance of CRYPTO-LEX is comparable to that of CALAS for detection of cryptococcal antigen in serum and CSF. PMID:7814566
Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen
2016-07-01
Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.
2014-01-01
Background The aim of this discovery study was the identification of peptide serum biomarkers for detecting biliary tract cancer (BTC) using samples from healthy volunteers and benign cases of biliary disease as control groups. This work was based on the hypothesis that cancer-specific exopeptidases exist and that their activities in serum can generate cancer-predictive peptide fragments from circulating proteins during coagulation. Methods This case control study used a semi-automated platform incorporating polypeptide extraction linked to matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) to profile 92 patient serum samples. Predictive models were generated to test a validation serum set from BTC cases and healthy volunteers. Results Several peptide peaks were found that could significantly differentiate BTC patients from healthy controls and benign biliary disease. A predictive model resulted in a sensitivity of 100% and a specificity of 93.8% in detecting BTC in the validation set, whilst another model gave a sensitivity of 79.5% and a specificity of 83.9% in discriminating BTC from benign biliary disease samples in the training set. Discriminatory peaks were identified by tandem MS as fragments of abundant clotting proteins. Conclusions Serum MALDI MS peptide signatures can accurately discriminate patients with BTC from healthy volunteers. PMID:24495412
Chantada-Vázquez, María Pilar; de-Becerra-Sánchez, Carolina; Fernández-Del-Río, Alba; Sánchez-González, Juan; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2018-05-01
A molecularly imprinted polymer - Mn-doped ZnS quantum dot-based fluorescence probe for cocaine abuse screening has been prepared and applied to complex samples such as serum and oral fluid. The fluorescent sensing material was prepared by anchoring a selective MIP for COC on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). Simple and low cost methods have thus been optimized for assessing cocaine abuse in serum and oral fluid by monitoring fluorescence quenching when cocaine (COC) is present (optimized operating conditions with 1.5mL of 200mgL -1 MIP-coated QDs solution, pH 5.5, and 15min before fluorescence scanning). The matrix effect was found to be important when analyzing oral fluid and serum, and several strategies based on centrifugation for oral fluid and solid phase extraction (SPE) for serum were explored. Two analytical methods were developed for oral fluid. The first one (direct method) requires a centrifugation step (6°C, 4000rpm, 20min) to avoid the matrix effect, and allows for cocaine determination by using an aqueous calibration (1:20 dilution). The second method was developed for oral fluid sampled by Salivette devices, and also requires a further centrifugation (6°C, 4000rpm, 20min) of the recovered oral fluid. This method, however, requires the standard addition technique (1:20 dilution) because of the existence of the matrix effect. Regarding serum samples, a direct method (serum dilution) was not possible, and an SPE procedure was needed to avoid the matrix effect (use of aqueous calibration). The limits of detection and quantification when using the Salivette method were 0.035mgL -1 and 0.117mgL -1, respectively; whereas, 0.015mgL -1 (LOD) and 0.050mgL -1 (LOQ) were obtained for serum. Copyright © 2018 Elsevier B.V. All rights reserved.
Validity and Reliability of Perinatal Biomarkers after Storage as Dry Blood Spots on Paper
Mihalopoulos, Nicole L.; Phillips, Terry M.; Slater, Hillarie; Thomson, J. Anne; Varner, Michael W.; Moyer-Mileur, Laurie J.
2013-01-01
Ojective To validate use of chip-based immunoaffinity capillary electrophoresis on dry blood spot samples (DBSS) to measure obesity-related cytokines. Methods Chip-based immunoaffinity capillary electrophoresis was used to measure adiponectin, leptin and insulin in serum and DBSS in pregnant women, cord blood, and infant heelstick at birth and 6 weeks. Concordance of measurements was determined with Pearson's correlation. Results We report high concordance between results obtained from serum and DBSS with the exception of cord blood specimens. Conclusions Ease of sample collection and storage makes DBSS an optimal method for use in studies involving neonates and young children. PMID:21735507
Xie, Gui-lin; Yin, Jun-xia; Duan, Xin-yu; Feng, Xiao-hui; Wang, Yang; Jiang, Kai; Chen, Xin-mei
2015-06-01
One hundred and fifty-nine serum samples from hydatid disease patients and 80 serum samples from patients with other liver diseases were detected by gold-immunochromatographic assay, and read by naked eyes and the gold-immunochromatographic test strip reader. The sensitivity, specificity, and accuracy of eye-based method was 92.4% (147/159), 85.0% (68/80), and 89.9% (215/239), which was lower than that of the reader detection (95.6%, 93.7%, 95.0%, respectively). While, its false negative rate (7.5%, 12/159) and false positive rate (15.0%, 12/80) was higher than that of the reader detection (4.4% and 6.3%, respectively).
Serum Albumin Domain Structures in Human Blood Serum by Mass Spectrometry and Computational Biology.
Belsom, Adam; Schneider, Michael; Fischer, Lutz; Brock, Oliver; Rappsilber, Juri
2016-03-01
Chemical cross-linking combined with mass spectrometry has proven useful for studying protein-protein interactions and protein structure, however the low density of cross-link data has so far precluded its use in determining structures de novo. Cross-linking density has been typically limited by the chemical selectivity of the standard cross-linking reagents that are commonly used for protein cross-linking. We have implemented the use of a heterobifunctional cross-linking reagent, sulfosuccinimidyl 4,4'-azipentanoate (sulfo-SDA), combining a traditional sulfo-N-hydroxysuccinimide (sulfo-NHS) ester and a UV photoactivatable diazirine group. This diazirine yields a highly reactive and promiscuous carbene species, the net result being a greatly increased number of cross-links compared with homobifunctional, NHS-based cross-linkers. We present a novel methodology that combines the use of this high density photo-cross-linking data with conformational space search to investigate the structure of human serum albumin domains, from purified samples, and in its native environment, human blood serum. Our approach is able to determine human serum albumin domain structures with good accuracy: root-mean-square deviation to crystal structure are 2.8/5.6/2.9 Å (purified samples) and 4.5/5.9/4.8Å (serum samples) for domains A/B/C for the first selected structure; 2.5/4.9/2.9 Å (purified samples) and 3.5/5.2/3.8 Å (serum samples) for the best out of top five selected structures. Our proof-of-concept study on human serum albumin demonstrates initial potential of our approach for determining the structures of more proteins in the complex biological contexts in which they function and which they may require for correct folding. Data are available via ProteomeXchange with identifier PXD001692. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Huh, Jung Wook; Kim, Sung Chun; Sohn, Insuk; Jung, Sin-Ho; Kim, Hee Cheol
2016-01-01
Background In this study, we established and validated a model for predicting prognosis of stage IIA colon cancer patients based on expression profiles of aptamers in serum. Methods Bloods samples were collected from 227 consecutive patients with pathologic T3N0M0 (stage IIA) colon cancer. We incubated 1,149 serum molecule-binding aptamer pools of clinical significance with serum from patients to obtain aptamers bound to serum molecules, which were then amplified and marked. Oligonucleotide arrays were constructed with the base sequences of the 1,149 aptamers, and the marked products identified above were reacted with one another to produce profiles of the aptamers bound to serum molecules. These profiles were organized into low- and high-risk groups of colon cancer patients based on clinical information for the serum samples. Cox proportional hazards model and leave-one-out cross-validation (LOOCV) were used to evaluate predictive performance. Results During a median follow-up period of 5 years, 29 of the 227 patients (11.9%) experienced recurrence. There were 212 patients (93.4%) in the low-risk group and 15 patients (6.6%) in the high-risk group in our aptamer prognosis model. Postoperative recurrence significantly correlated with age and aptamer risk stratification (p = 0.046 and p = 0.001, respectively). In multivariate analysis, aptamer risk stratification (p < 0.001) was an independent predictor of recurrence. Disease-free survival curves calculated according to aptamer risk level predicted through a LOOCV procedure and age showed significant differences (p < 0.001 from permutations). Conclusion Aptamer risk stratification can be a valuable prognostic factor in stage II colon cancer patients. PMID:26908450
Detection of a Serum Siderophore by LC-MS/MS as a Potential Biomarker of Invasive Aspergillosis
Carroll, Cassandra S.; Amankwa, Lawrence N.; Pinto, Linda J.; Fuller, Jeffrey D.; Moore, Margo M.
2016-01-01
Invasive aspergillosis (IA) is a life-threatening systemic mycosis caused primarily by Aspergillus fumigatus. Early diagnosis of IA is based, in part, on an immunoassay for circulating fungal cell wall carbohydrate, galactomannan (GM). However, a wide range of sensitivity and specificity rates have been reported for the GM test across various patient populations. To obtain iron in vivo, A. fumigatus secretes the siderophore, N,N',N"-triacetylfusarinine C (TAFC) and we hypothesize that TAFC may represent a possible biomarker for early detection of IA. We developed an ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for TAFC analysis from serum, and measured TAFC in serum samples collected from patients at risk for IA. The method showed lower and upper limits of quantitation (LOQ) of 5 ng/ml and 750 ng/ml, respectively, and complete TAFC recovery from spiked serum. As proof of concept, we evaluated 76 serum samples from 58 patients with suspected IA that were investigated for the presence of GM. Fourteen serum samples obtained from 11 patients diagnosed with probable or proven IA were also analyzed for the presence of TAFC. Control sera (n = 16) were analyzed to establish a TAFC cut-off value (≥6 ng/ml). Of the 36 GM-positive samples (≥0.5 GM index) from suspected IA patients, TAFC was considered positive in 25 (69%). TAFC was also found in 28 additional GM-negative samples. TAFC was detected in 4 of the 14 samples (28%) from patients with proven/probable aspergillosis. Log-transformed TAFC and GM values from patients with proven/probable IA, healthy individuals and SLE patients showed a significant correlation with a Pearson r value of 0.77. In summary, we have developed a method for the detection of TAFC in serum that revealed this fungal product in the sera of patients at risk for invasive aspergillosis. A prospective study is warranted to determine whether this method provides improved early detection of IA. PMID:26974544
Reed, S M; Howe, D K; Morrow, J K; Graves, A; Yeargan, M R; Johnson, A L; MacKay, R J; Furr, M; Saville, W J A; Williams, N M
2013-01-01
Recent work demonstrated the value of antigen-specific antibody indices (AI and C-value) to detect intrathecal antibody production against Sarcocystis neurona for antemortem diagnosis of equine protozoal myeloencephalitis (EPM). The study was conducted to assess whether the antigen-specific antibody indices can be reduced to a simple serum : cerebrospinal fluid (CSF) titer ratio to achieve accurate EPM diagnosis. Paired serum and CSF samples from 128 horses diagnosed by postmortem examination. The sample set included 44 EPM cases, 35 cervical-vertebral malformation (CVM) cases, 39 neurologic cases other than EPM or CVM, and 10 non-neurologic cases. Antibodies against S. neurona were measured in serum and CSF pairs using the SnSAG2 and SnSAG4/3 (SnSAG2, 4/3) ELISAs, and the ratio of each respective serum titer to CSF titer was determined. Likelihood ratios and diagnostic sensitivity and specificity were calculated based on serum titers, CSF titers, and serum : CSF titer ratios. Excellent diagnostic sensitivity and specificity was obtained from the SnSAG2, 4/3 serum : CSF titer ratio. Sensitivity and specificity of 93.2 and 81.1%, respectively, were achieved using a ratio cutoff of ≤100, whereas sensitivity and specificity were 86.4 and 95.9%, respectively, if a more rigorous cutoff of ≤50 was used. Antibody titers in CSF also provided good diagnostic accuracy. Serum antibody titers alone yielded much lower sensitivity and specificity. The study confirms the value of detecting intrathecal antibody production for antemortem diagnosis of EPM, and they further show that the antigen-specific antibody indices can be reduced in practice to a simple serum : CSF titer ratio. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Fast detection of Piscirickettsia salmonis in Salmo salar serum through MALDI-TOF-MS profiling.
Olate, Verónica R; Nachtigall, Fabiane M; Santos, Leonardo S; Soto, Alex; Araya, Macarena; Oyanedel, Sandra; Díaz, Verónica; Marchant, Vanessa; Rios-Momberg, Mauricio
2016-03-01
Piscirickettsia salmonis is a pathogenic bacteria known as the aetiological agent of the salmonid rickettsial syndrome and causes a high mortality in farmed salmonid fishes. Detection of P. salmonis in farmed fishes is based mainly on molecular biology and immunohistochemistry techniques. These techniques are in most of the cases expensive and time consuming. In the search of new alternatives to detect the presence of P. salmonis in salmonid fishes, this work proposed the use of MALDI-TOF-MS to compare serum protein profiles from Salmo salar fish, including experimentally infected and non-infected fishes using principal component analysis (PCA). Samples were obtained from a controlled bioassay where S. salar was challenged with P. salmonis in a cohabitation model and classified according to the presence or absence of the bacteria by real time PCR analysis. MALDI spectra of the fish serum samples showed differences in its serum protein composition. These differences were corroborated with PCA analysis. The results demonstrated that the use of both MALDI-TOF-MS and PCA represents a useful tool to discriminate the fish status through the analysis of salmonid serum samples. Copyright © 2016 John Wiley & Sons, Ltd.
A comparison of serum and plasma cytokine values using a multiplexed assay in cats.
Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X
2016-12-01
Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Non-invasive optical detection of HBV based on serum surface-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Zheng, Zuci; Wang, Qiwen; Weng, Cuncheng; Lin, Xueliang; Lin, Yao; Feng, Shangyuan
2016-10-01
An optical method of surface-enhanced Raman spectroscopy (SERS) was developed for non-invasive detection of hepatitis B surface virus (HBV). Hepatitis B virus surface antigen (HBsAg) is an established serological marker that is routinely used for the diagnosis of acute or chronic hepatitis B virus(HBV) infection. Utilizing SERS to analyze blood serum for detecting HBV has not been reported in previous literature. SERS measurements were performed on two groups of serum samples: one group for 50 HBV patients and the other group for 50 healthy volunteers. Blood serum samples are collected from healthy control subjects and patients diagnosed with HBV. Furthermore, principal components analysis (PCA) combined with linear discriminant analysis (LDA) were employed to differentiate HBV patients from healthy volunteer and achieved sensitivity of 80.0% and specificity of 74.0%. This exploratory work demonstrates that SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of HBV.
Marques, Sara S.; Magalhães, Luís M.; Tóth, Ildikó V.; Segundo, Marcela A.
2014-01-01
Total antioxidant capacity assays are recognized as instrumental to establish antioxidant status of biological samples, however the varying experimental conditions result in conclusions that may not be transposable to other settings. After selection of the complexing agent, reagent addition order, buffer type and concentration, copper reducing assays were adapted to a high-throughput scheme and validated using model biological antioxidant compounds of ascorbic acid, Trolox (a soluble analogue of vitamin E), uric acid and glutathione. A critical comparison was made based on real samples including NIST-909c human serum certified sample, and five study samples. The validated method provided linear range up to 100 µM Trolox, (limit of detection 2.3 µM; limit of quantification 7.7 µM) with recovery results above 85% and precision <5%. The validated developed method with an increased sensitivity is a sound choice for assessment of TAC in serum samples. PMID:24968275
Kucherenko, I S; Soldatkin, O O; Lagarde, F; Jaffrezic-Renault, N; Dzyadevych, S V; Soldatkin, A P
2015-11-01
Creatine kinase (CK: adenosine-5-triphosphate-creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme in blood serum is a biomarker of muscular injuries, such as acute myocardial infarction. This work describes a bi-enzyme (glucose oxidase and hexokinase based) biosensor for rapid and convenient determination of CK activity by measuring the rate of ATP production by this enzyme. Simultaneously the biosensor determines glucose concentration in the sample. Platinum disk electrodes were used as amperometric transducers. Glucose oxidase and hexokinase were co-immobilized via cross-linking with BSA by glutaraldehyde and served as a biorecognition element of the biosensor. The biosensor work at different concentrations of CK substrates (ADP and creatine phosphate) was investigated; optimal concentration of ADP was 1mM, and creatine phosphate - 10 mM. The reproducibility of the biosensor responses to glucose, ATP and CK during a day was tested (relative standard deviation of 15 responses to glucose was 2%, to ATP - 6%, to CK - 7-18% depending on concentration of the CK). Total time of CK analysis was 10 min. The measurements of creatine kinase in blood serum samples were carried out (at 20-fold sample dilution). Twentyfold dilution of serum samples was chosen as optimal for CK determination. The biosensor could distinguish healthy and ill people and evaluate the level of CK increase. Thus, the biosensor can be used as a test-system for CK analysis in blood serum or serve as a component of multibiosensors for determination of important blood substances. Determination of activity of other kinases by the developed biosensor is also possible for research purposes. Copyright © 2015 Elsevier B.V. All rights reserved.
Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun
2014-02-01
Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from
NASA Astrophysics Data System (ADS)
Jafari, Marzieh; Tashkhourian, Javad; Absalan, Ghodratollah
2017-10-01
A simple, fast and green method for chiral recognition of S- and R-naproxen has been introduced. The method was based on quenching of the fluorescence intensity of bovine serum albumin-stabilized gold nanoclusters in the presence of naproxen enantiomers. The quenching intensity in the presence of S-naproxen was higher than R-naproxen when phosphate buffer solution at pH 7.0 was used. The chiral recognition occurred due to steric effect between bovine serum albumin conformation and naproxen enantiomers. Two linear determination range were established as 7.4 × 10-7-9.1 × 10-6 and 9.1 × 10-6-3.1 × 10-5 mol L-1 for both enantiomers and detection limits of 7.4 × 10-8 mol L- 1 and 9.5 × 10-8 mol L-1 were obtained for S- and R-naproxen, respectively. The developed method showed good repeatability and reproducibility for the analysis of a synthetic sample. To make the procedure applicable to biological samples, the removal of heavy metals from the sample is suggested before any analytical attempt.
Analyte stability during the total testing process: studies of vitamins A, D and E by LC-MS/MS.
Albahrani, Ali A; Rotarou, Victor; Roche, Peter J; Greaves, Ronda F
2016-10-01
There are limited evidence based studies demonstrating the stability of fat-soluble vitamins (FSV) measured in blood. This study aimed to examine the effects of light, temperature and time on vitamins A, D and E throughout the total testing process. Four experiments were conducted. Three investigated the sample matrix, of whole blood, serum and the extracted sample, against the variables of temperature and light; and the fourth experiment investigated the sample during the extraction process against the variable of light. All samples were analysed via our simultaneous FSV method using liquid chromatography-tandem mass spectrometry technology. The allowable clinical percentage change was calculated based on biological variation and desirable method imprecision for each analyte. The total change limit was ±7.3% for 25-OH-vitamin D3, ±11.8% for retinol and ±10.8% for α-tocopherol. Vitamins D and E were stable in the investigated conditions (concentration changes <4%) in the pre-analytical and analytical stages. Vitamin A showed photosensitivity in times >48 h with concentration changes of -6.8% (blood) and -6.5% (serum), both are within the allowable clinical percentage change. By contrast, the extracted retinol sample demonstrated a concentration change of -18.4% after 48 h of light exposure. However, vitamin A in the serum and extracted solution was stable for one month when stored at -20°C. Blood samples for vitamins D and E analyses can be processed in normal laboratory conditions of lighting and temperature. The required conditions for vitamin A analysis are similar when performed within 48 h. For longer-term storage, serum and vitamin A extracts should be stored at -20°C.
Colon Reference Set Application: Mary Disis - University of Washington (2008) — EDRN Public Portal
The proposed study aims to validate the diagnostic value of a panel of serum antibodies for the early detection of colorectal cancer (CRC). We have developed a serum antibody based assay that shows promise in discriminating sera from CRC patients from healthy donors. We have evaluated two separate sample sets of sera that were available either commercially or were comprised of left over samples from previous studies by our group. Both sample sets showed concordance in discriminatory power. We have not been able to identify investigators with a larger, well defined sample set of early stage colon cancer sera and request assistance from the EDRN in obtaining such samples to help assess the potential diagnostic value of our autoantibody panel
Klohonatz, Kristin M; Cameron, Ashely D; Hergenreder, Joanna R; da Silveira, Juliano C; Belk, Aeriel D; Veeramachaneni, D N R; Bouma, Gerrit J; Bruemmer, Jason E
2016-12-01
During early pregnancy, the conceptus and mare communicate to establish pregnancy. Cell-secreted vesicles (e.g., exosomes) have been reported in serum. Exosomes contain bioactive materials, such as miRNA, that can mediate cell responses. We hypothesized that a) exosomes are present in mare circulation and quantity varies with pregnancy status, b) exosomes contain miRNAs unique to pregnancy status, and c) miRNAs target pathways in endometrium based upon pregnancy status of the mare. First, serum samples were obtained from mares in a crossover design, with each mare providing samples from a pregnant and nonmated control cycle (n = 3/sample day) on Days 12, 14, 16, and 18 postovulation. Flow cytometry revealed the presence of serum microvesicles in mares in two different-sized populations (greater than or less than 100 nm), validated by transmission electron microscopy. Second, serum was collected on Days 9, 11, and 13 (n = 4/day), and endometrial biopsies were collected on Days 11 and 13 (n = 3/day) from pregnant and nonmated mares. Total RNA from serum exosomes was evaluated with quantitative RT-PCR using equine-specific miRNA sequences. A total of 12 miRNAs were found in different quantities on the specified days. Pathway analysis suggested that miRNAs targeted focal adhesion molecules (FAMs). Transcripts corresponding to FAMs were evaluated in endometrial biopsies. Protein levels and localization for PAK6 and RAF1 were further evaluated. Our data suggest that serum exosomes contain miRNA that differ based upon pregnancy status, and may affect mRNA expression related to focal adhesion pathway in the endometrium, with a potential role in maternal recognition of pregnancy. © 2016 by the Society for the Study of Reproduction, Inc.
Korse, Catharina M; Buning-Kager, Johanna C G M; Linders, Theodora C; Heijboer, Annemieke C; van den Broek, Daan; Tesselaar, Margot E T; van Tellingen, Olaf; van Rossum, Huub H
2017-06-01
Serotonin is used for the diagnosis and follow-up of neuroendocrine tumors (NET). We describe the analytical and clinical validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) based serotonin assay for serum and platelet-rich plasma (PRP). An LC-MS/MS based method for serum and PRP serotonin was validated by determination of assay imprecision, carry-over, linearity, interference, recovery, sample stability and a matrix/method comparison of serum and PRP serotonin was made with whole blood serotonin. Furthermore, upper limits of normal were determined and serotonin concentrations of healthy individuals, 14 NET patients without evidence of disease and 51 NET patients with evidence of disease were compared. For serum and PRP fractions, total assay imprecision was <5%. All correlation coefficients were 0.98 and the serum and platelet-rich serotonin upper limit of normal were 5.5nmol/10 9 platelet and 5.1nmol/10 9 platelet, respectively. NET patients with confirmed evidence of disease had significantly higher serum and PRP serotonin levels when compared to NET patients without evidence of disease and healthy volunteers. LC-MS/MS based serum and PRP serotonin assays were developed with suitable analytical characteristics. Furthermore, serum and PRP serotonin was found to be useful for monitoring NET patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Marshall, Nicole E; Fraley, Gwen; Feist, Cori; Burns, Michael J; Pereira, Leonardo
2012-08-01
To determine the prevalence of abnormal karyotype results in women undergoing chorionic villus sampling (CVS) for abnormal first trimester screening compared to CVS for historical indications (advanced maternal age (AMA) or prior aneuploidy). Retrospective cohort of all patients undergoing CVS at Oregon Health & Science University from January 2006 to June 2010. Patients were separated based on CVS indication: (1) positive ultrasound (U/S) or serum screening; or (2) AMA or prior aneuploidy with normal or no screening. Prevalence of abnormal karyotype results were compared between groups. Fetal karyotyping was successful in 500 of 506 CVS procedures performed. 203 CVS were performed for positive screening with 69 abnormal karyotypes (34.0%). 264 CVS were performed for historical indications with 11 abnormal karyotypes (4.2%). This difference was statistically significant (χ(2) 71.9, p < 0.001; OR 11.8 [95% CI 5.8, 24.6]). There were two age-related aneuplodies in AMA women without positive screening. 42 out of 44 AMA women diagnosed with aneuploidy (95.5%) had abnormal U/S and/or serum screening (35 U/S, 4 serum, 3 U/S and serum). Combined ultrasound and serum screening should be recommended to all women, including AMA women, prior to undergoing invasive testing to improve risk-based counseling and minimize morbidity.
Highly sensitive dendrimer-based nanoplasmonic biosensor for drug allergy diagnosis.
Soler, Maria; Mesa-Antunez, Pablo; Estevez, M-Carmen; Ruiz-Sanchez, Antonio Jesus; Otte, Marinus A; Sepulveda, Borja; Collado, Daniel; Mayorga, Cristobalina; Torres, Maria Jose; Perez-Inestrosa, Ezequiel; Lechuga, Laura M
2015-04-15
A label-free biosensing strategy for amoxicillin (AX) allergy diagnosis based on the combination of novel dendrimer-based conjugates and a recently developed nanoplasmonic sensor technology is reported. Gold nanodisks were functionalized with a custom-designed thiol-ending-polyamido-based dendron (d-BAPAD) peripherally decorated with amoxicilloyl (AXO) groups (d-BAPAD-AXO) in order to detect specific IgE generated in patient's serum against this antibiotic during an allergy outbreak. This innovative strategy, which follows a simple one-step immobilization procedure, shows exceptional results in terms of sensitivity and robustness, leading to a highly-reproducible and long-term stable surface which allows achieving extremely low limits of detection. Moreover, the viability of this biosensor approach to analyze human biological samples has been demonstrated by directly analyzing and quantifying specific anti-AX antibodies in patient's serum without any sample pretreatment. An excellent limit of detection (LoD) of 0.6ng/mL (i.e. 0.25kU/L) has been achieved in the evaluation of clinical samples evidencing the potential of our nanoplasmonic biosensor as an advanced diagnostic tool to quickly identify allergic patients. The results have been compared and validated with a conventional clinical immunofluorescence assay (ImmunoCAP test), confirming an excellent correlation between both techniques. The combination of a novel compact nanoplasmonic platform and a dendrimer-based strategy provides a highly sensitive label free biosensor approach with over two times better detectability than conventional SPR. Both the biosensor device and the carrier structure hold great potential in clinical diagnosis for biomarker analysis in whole serum samples and other human biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Preparation of the low molecular weight serum proteome for mass spectrometry analysis.
Waybright, Timothy J; Chan, King C; Veenstra, Timothy D; Xiao, Zhen
2013-01-01
The discovery of viable biomarkers or indicators of disease states is complicated by the inherent complexity of the chosen biological specimen. Every sample, whether it is serum, plasma, urine, tissue, cells, or a host of others, contains thousands of large and small components, each interacting in multiple ways. The need to concentrate on a group of these components to narrow the focus on a potential biomarker candidate becomes, out of necessity, a priority, especially in the search for immune-related low molecular weight serum biomarkers. One such method in the field of proteomics is to divide the sample proteome into groups based on the size of the protein, analyze each group, and mine the data for statistically significant items. This chapter details a portion of this method, concentrating on a method for fractionating and analyzing the low molecular weight proteome of human serum.
Zhu, Guijie; Zhao, Peng; Deng, Nan; Tao, Dingyin; Sun, Liangliang; Liang, Zhen; Zhang, Lihua; Zhang, Yukui
2012-09-18
Single chain variable fragment (scFv) displaying the M13 phage library was covalently immobilized on magnetic microspheres and used as a protein equalizer for the treatment of human serum. First, scFv displaying M13 phage library functionalized magnetic microspheres (scFv@M13@MM) was incubated with a human serum sample. Second, captured proteins on scFv@M13@MM were eluted with 2 M NaCl, 50 mM glycine-hydrochloric acid (Gly-HCl), and 20% (v/v) acetonitrile with 0.5% (v/v) trifluoroacetic acid in sequence. Finally, the tightly bonded proteins were released by the treatment with thrombin. The eluates were first analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) with silver staining. Results indicated that the difference of protein concentration was reduced obviously in NaCl and Gly-HCl fractions compared with untreated human serum sample. The eluates were also digested with trypsin, followed by online 2D-strong cation exchange (SCX)-RPLC-ESI-MS/MS analysis. Results demonstrated that the number of proteins identified from an scFv@M13@MM treated human serum sample was improved 100% compared with that from the untreated sample. In addition, the spectral count of 10 high abundance proteins (serum albumin, serotransferrin, α-2-macroglobulin, α-1-antitrypsin, apolipoprotein B-100, Ig γ-2 chain C region, haptoglobin, hemopexin, α-1-acid glycoprotein 1, and α-2-HS-glycoprotein) decreased evidently after scFv@M13@MM treatment. All these results demonstrate that scFv@M13@MM could efficiently remove high-abundance proteins, reduce the protein concentration difference of human serum, and result in more protein identification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ehresman, David J.; Froehlich, John W.; Olsen, Geary W.
2007-02-15
Interest in human exposure to perfluorinated acids, including perfluorobutanesulfonate (PFBS), perfluorohexanesulfonate (PFHS), perfluorooctanesulfonate (PFOS), and perfluorooctanoate (PFOA) has led to their measurement in whole blood, plasma and serum. Comparison of measurements in these different blood-based matrices, however, has not been rigorously investigated to allow for across-matrix comparisons. This research evaluated concentrations of PFBS, PFHS, PFOS, and PFOA in whole blood collected in heparin (lithium) and ethylenediamine tetraacetic acid (EDTA), plasma samples collected in heparin and EDTA, and serum (from whole blood allowed to clot). Blood samples were collected from 18 voluntary participants employed at 3M Company. Solid phase extraction methodsmore » were used for all analytical sample preparations, and analyses were completed using high-pressure liquid chromatography/tandem mass spectrometry methods. Serum concentrations ranged from: limit of quantitation (LOQ, 5 ng/mL) to 25 ng/mL for PFBS; LOQ (5 ng/mL) to 75 ng/mL for PFHS; LOQ (5 ng/mL) to 880 ng/mL for PFOS; and LOQ (5 or 10 ng/mL) to 7320 ng/mL for PFOA. Values less than the LOQ were not included in the statistical analyses of the mean of the ratios of individual values for the matrices. PFBS was not quantifiable in most samples. Serum to plasma ratios for PFHS, PFOS, and PFOA were 1:1 and this ratio was independent of the level of concentrations measured. Serum or plasma to whole blood ratios, regardless of the anticoagulant used, approximated 2:1. The difference between plasma and serum and whole blood corresponded to volume displacement by red blood cells, suggesting that the fluorochemicals are not found intracellularly or attached to the red blood cells.« less
An aptamer nanopore-enabled microsensor for detection of theophylline.
Feng, Silu; Chen, Changtian; Wang, Wei; Que, Long
2018-05-15
This paper reports an aptamer-based nanopore thin film sensor for detecting theophylline in the buffer solution and complex fluids including plant extracts and serum samples. Compared to antibody-based detection, aptamer-based detection offers many advantages such as low cost and high stability at elevated temperatures. Experiments found that this type of sensor can readily detect theophylline at a concentration as low as 0.05µM, which is much lower than the detection limit of current lab-based equipment such as liquid chromatography (LC). Experiments also found that the aptamer-based sensor has good specificity, selectivity, and reasonable reusability with a significantly improved dynamic detection range. By using the same nanopore thin film sensors as the reference sensors to further mitigate the non-specific binding effect, the theophylline in plant extracts and serum has been detected. Only a small amount (~1μL) of plant extracts or serum samples is required to measure theophylline. Its low cost and ease-of-operation make this type of sensor suitable for point-of-care application to monitor the theophylline level of patients in real time. Copyright © 2018 Elsevier B.V. All rights reserved.
Wan, Yanjian; Xia, Wei; Yang, Shunyi; Pan, Xinyun; He, Zhenyu; Kannan, Kurunthachalam
2018-05-01
Bisphenol S (BPS) is an emerging environmental contaminant. The occurrence of this compound in humans and the environment is not well described. In this study, 120 surface water samples and 240 human serum samples were collected along the Yangtze River in 2015 for the determination of the occurrence of BPS. Surface water and human serum samples were extracted by solid phase extraction and liquid-liquid extraction, respectively, and analyzed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). BPS was detected in all river water samples at concentrations that ranged from 0.18 to 14.9 ng/L (median: 0.98 ng/L), with higher concentrations in spring than summer. The median estimated daily intake (EDI) of BPS through water ingestion by infants in spring and summer was 0.12 and 0.06 ng/kg body weight (bw)/day, respectively. BPS was detected in human serum with the highest concentrations in samples from Nanjing (median: 0.65 ng/mL, maximum: 169 ng/mL) among the four cities studied. No significant gender related difference in BPS concentrations was observed in human sera, while higher concentrations were found in younger individuals than elderly. The EDI of BPS calculated based on serum concentrations of adults in Nanjing was 22.8 ng/kg bw/day. Ingestion of water accounted for <1% of the total BPS intake by the Chinese population. This is the first report of the occurrence of BPS in water from the Yangtze River and human serum from several cities located along this river in China. Copyright © 2018 Elsevier Ltd. All rights reserved.
Vosough, Maryam; Ghafghazi, Shiva; Sabetkasaei, Masoumeh
2014-02-01
This paper describes development and validation of a simple and efficient bioanalytical procedure for simultaneous determination of phenobarbital and carbamazepine in human serum samples using high performance liquid chromatography with photodiode-array detection (HPLC-DAD) regarding a fast elution methodology in less than 5 min. Briefly, this method consisted of a simple deproteinization step of serum samples followed by HPLC analysis on a Bonus-RP column using an isocratic mode of elution with acetonitrile/K2HPO4 (pH=7.5) buffer solution (45:55). Due to the presence of serum endogenous components as non-calibrated components in the sample, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS), has been applied on a set of absorbance matrices collected as a function of retention time and wavelengths. Acceptable resolution and quantification results were achieved in the presence of matrix interferences and the second-order advantage was fully exploited. The average recoveries for carbamazepine and phenobarbital were 89.7% and 86.1% and relative standard deviation values were lower than 9%. Additionally, computed elliptical joint confidence region (EJCR) confirmed the accuracy of the proposed method and indicated the absence of both constant and proportional errors in the predicted concentrations. The developed method enabled the determination of the analytes in different serum samples in the presence of overlapped profiles, while keeping experimental time and extraction steps at minimum. Finally, the serum concentration levels of carbamazepine in three time intervals were reported for morphine-dependents who had received carbamazepine for treating their neuropathic pain. © 2013 Elsevier B.V. All rights reserved.
Use of dried blood spots for the determination of serum concentrations of tamoxifen and endoxifen.
Jager, N G L; Rosing, H; Schellens, J H M; Beijnen, J H; Linn, S C
2014-07-01
The anti-estrogenic effect of tamoxifen is suggested to be mainly attributable to its metabolite (Z)-endoxifen, and a minimum therapeutic threshold for (Z)-endoxifen in serum has been proposed. The objective of this research was to establish the relationship between dried blood spot (DBS) and serum concentrations of tamoxifen and (Z)-endoxifen to allow the use of DBS sampling, a simple and patient-friendly alternative to venous sampling, in clinical practice. Paired DBS and serum samples were obtained from 50 patients using tamoxifen and analyzed using HPLC-MS/MS. Serum concentrations were calculated from DBS concentrations using the formula calculated serum concentration = DBS concentration/([1-haematocrit (Hct)] + blood cell-to-serum ratio × Hct). The blood cell-to-serum ratio was determined ex vivo by incubating a batch of whole blood spiked with both analytes. The average Hct for female adults was imputed as a fixed value. Calculated and analyzed serum concentrations were compared using weighted Deming regression. Weighted Deming regression analysis comparing 44 matching pairs of DBS and serum samples showed a proportional bias for both analytes. Serum concentrations were calculated using [Tamoxifen] serum, calculated = [Tamoxifen] DBS /0.779 and [(Z)-Endoxifen] serum, calculated = [(Z)-Endoxifen] DBS /0.663. Calculated serum concentrations were within 20 % of analyzed serum concentrations in 84 and 100 % of patient samples for tamoxifen and (Z)-endoxifen, respectively. In conclusion, DBS concentrations of tamoxifen and (Z)-endoxifen were equal to serum concentrations after correction for Hct and blood cell-to-serum ratio. DBS sampling can be used in clinical practice.
NASA Astrophysics Data System (ADS)
Ignatov, D.; Zhurbina, N.; Gerasimenko, A.
2017-01-01
3-D composites are widely used in tissue engineering. A comprehensive analysis by X-ray microtomography was conducted to study the structure of the 3-D composites. Comprehensive analysis of the structure of the 3-D composites consisted of scanning, image reconstruction of shadow projections, two-dimensional and three-dimensional visualization of the reconstructed images and quantitative analysis of the samples. Experimental samples of composites were formed by laser vaporization of the aqueous dispersion BSA and single-walled (SWCNTs) and multi-layer (MWCNTs) carbon nanotubes. The samples have a homogeneous structure over the entire volume, the percentage of porosity of 3-D composites based on SWCNTs and MWCNTs - 16.44%, 28.31%, respectively. An average pore diameter of 3-D composites based on SWCNTs and MWCNTs - 45 μm 93 μm. 3-D composites based on carbon nanotubes in bovine serum albumin matrix can be used in tissue engineering of bone and cartilage, providing cell proliferation and blood vessel sprouting.
A fully-integrated aptamer-based affinity assay platform for monitoring astronaut health in space.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xianbin; Durland, Ross H.; Hecht, Ariel H.
2010-07-01
Here we demonstrate the suitability of robust nucleic acid affinity reagents in an integrated point-of-care diagnostic platform for monitoring proteomic biomarkers indicative of astronaut health in spaceflight applications. A model thioaptamer targeting nuclear factor-kappa B (NF-{kappa}B) is evaluated in an on-chip electrophoretic gel-shift assay for human serum. Key steps of (i) mixing sample with the aptamer, (ii) buffer exchange, and (iii) preconcentration of sample were successfully integrated upstream of fluorescence-based detection. Challenges due to (i) nonspecific interactions with serum, and (ii) preconcentration at a nanoporous membrane are discussed and successfully resolved to yield a robust, rapid, and fully-integrated diagnostic system.
Ramos-Trautmann, Grisel; González, Lilliana; Díaz-Luquis, Giselle; Pérez, Cynthia M; Palacios, Cristina
2015-04-01
Vitamin D deficiency is a public health problem around the world. Diabetes has been associated with vitamin D deficiency. We aimed to examine the association between the vitamin D status and diabetes in a clinic based sample of Hispanic adults in Puerto Rico. Demographics and laboratory test results for serum 25(OH)D, Fasting Blood Glucose (FBG), and Haemoglobin A1C (HbAlc) were extracted from medical records. Vitamin D status was classified as deficient (<12 ng/ml); inadequate (12-20 ng/ml); insufficient (21-29 ng/ml) and optimal (≥30 ng/ml) using serum 25(OH)D levels. A total of 716 records were included in the analyses. Most were females (63.3%), with mean age of 54.1±14.9 y, mean BMI 30.1±6.3 kg/m2 and mean serum 25(OH)D levels of 24.3±8.6 ng/ml. Most were classified as diabetics (41.1%). Those with diabetes had lower 25(OH)D levels compared to pre-diabetic and normal glucose status (p<0.05). Serum 25(OH) D levels were inversely correlated to FBG and HbA1c in the total sample and in men (p<0.05). After adjusting for age, gender, BMI and seasonality, there was a greater risk of diabetes, but not prediabetes, in those with serum 25(OH)D levels <30 ng/ml. This risk increased from 1.8 times in those with vitamin D insufficiency to 4.2 times in those with vitamin D deficiency (<12 ng/ml). Diabetes risk significantly increased as serum 25(OH)D levels decreased in this group of Hispanic adults, underscoring the importance of routinely screening high risk individuals for vitamin D deficiency and offer supplementation to normalize serum levels.
Ramos-Trautmann, Grisel; González, Lilliana; Díaz-Luquis, Giselle; Pérez, Cynthia M.; Palacios, Cristina
2017-01-01
Background Vitamin D deficiency is a public health problem around the world. Diabetes has been associated with vitamin D deficiency. We aimed to examine the association between the vitamin D status and diabetes in a clinic based sample of Hispanic adults in Puerto Rico. Methods Demographics and laboratory test results for serum 25(OH)D, Fasting Blood Glucose (FBG), and Haemoglobin A1C (HbAlc) were extracted from medical records. Vitamin D status was classified as deficient (<12 ng/ml); inadequate (12–20 ng/ml); insufficient (21–29 ng/ml) and optimal (≥30 ng/ml) using serum 25(OH)D levels. Results A total of 716 records were included in the analyses. Most were females (63.3%), with mean age of 54.1±14.9 y, mean BMI 30.1±6.3 kg/m2 and mean serum 25(OH)D levels of 24.3±8.6 ng/ml. Most were classified as diabetics (41.1%). Those with diabetes had lower 25(OH)D levels compared to pre-diabetic and normal glucose status (p<0.05). Serum 25(OH) D levels were inversely correlated to FBG and HbA1c in the total sample and in men (p<0.05). After adjusting for age, gender, BMI and seasonality, there was a greater risk of diabetes, but not prediabetes, in those with serum 25(OH)D levels <30 ng/ml. This risk increased from 1.8 times in those with vitamin D insufficiency to 4.2 times in those with vitamin D deficiency (<12 ng/ml). Conclusion Diabetes risk significantly increased as serum 25(OH)D levels decreased in this group of Hispanic adults, underscoring the importance of routinely screening high risk individuals for vitamin D deficiency and offer supplementation to normalize serum levels. PMID:28345061
Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M
2016-09-01
We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.
Rowe, Aaron A.; Miller, Erin A.; Plaxco, Kevin W.
2011-01-01
Biosensors built using ribonucleic acid (RNA) aptamers show promise as tools for point-of-care medical diagnostics, but they remain vulnerable to nuclease degradation when deployed in clinical samples. To explore methods for protecting RNA-based biosensors from such degradation we have constructed and characterized an electrochemical, aptamer-based sensor for the detection of aminoglycosidic antibiotics. We find that while this sensor achieves low micromolar detection limits and subminute equilibration times when challenged in buffer, it deteriorates rapidly when immersed directly in blood serum. In order to circumvent this problem, we have developed and tested sensors employing modified versions of the same aptamer. Our first effort to this end entailed the methylation of all of the 2′-hydroxyl groups outside of the aptamer’s antibiotic binding pocket. However, while devices employing this modified aptamer are as sensitive as those employing an unmodified parent, the modification fails to confer greater stability when the sensor is challenged directly in blood serum. As a second potentially naive alternative, we replaced the RNA bases in the aptamer with their more degradation-resistant deoxyribonucleic acid (DNA) equivalents. Surprisingly and unlike control DNA-stem loops employing other sequences, this DNA aptamer retains the ability to bind aminoglycosides, albeit with poorer affinity than the parent RNA aptamer. Unfortunately, however, while sensors fabricated using this DNA aptamer are stable in blood serum, its lower affinity pushes their detection limits above the therapeutically relevant range. Finally, we find that ultrafiltration through a low-molecular-weight-cutoff spin column rapidly and efficiently removes the relevant nucleases from serum samples spiked with gentamicin, allowing the convenient detection of this aminoglycoside at clinically relevant concentrations using the original RNA-based sensor. PMID:20687587
Karataylı, Ersin; Altunoğlu, Yasemin Çelik; Karataylı, Senem Ceren; Yurdaydın, Cihan; Bozdayı, A Mithat
2014-10-01
Internal controls (ICs), are the main components of any real-time PCR based amplification methods, which are co-purified and co-amplified with the actual target. The existence of free circulating nucleic acids in plasma and serum (CNAPS) has been known for many years. The aim of this study was to verify whether CNAPS can be used as ICs in real-time PCR based detection and quantification of DNA or RNA targets in plasma and serum samples. Glyceraldehyde-3-phosphate dehydrogenase (GAPDH) as a housekeeping gene, was chosen at random as CNAPS to serve as an intrinsic internal control in two different real-time PCR based quantification models in plasma and serum. Viral loads of hepatitis B virus (HBV) DNA and hepatitis delta virus (HDV) RNA were quantified as actual targets in parallel to GAPDH as IC in a total of 519 serum or plasma samples including 21 healthy controls, 202 positive chronic hepatitis delta patients, 37 chronic hepatitis C patients, 168 chronic hepatitis B patients, 52 patients with hepatocellular carcinoma, and 39 patients with non-alcoholic steatohepatitis/non-alcoholic fatty liver disease. GAPDH levels did not show significant variance in different patient groups and yielded positive signals in all 519 patients with persistent cycle threshold (CT) values 27.85±1.57 (mean±standard deviation (SD)). Reproducibility of the GAPDH amplification in HDV RNA and HBV DNA quantifications was shown with a SD value of CT ranging from 0.42 to 2.14 (mean SD; 1.18) and 0.24 to 1.75 (mean SD; 1.03), respectively. In conclusion, the freely circulating nucleic acids can clearly be used as internal controls for real-time PCR based detection and quantification of any RNA and mainly DNA targets (pathogens) in serum or plasma and this simply excludes the compulsory external addition of any IC molecules into the reaction. Copyright © 2014 Elsevier B.V. All rights reserved.
Fulton, Robert W.; Hessman, Bill E.; Ridpath, Julia F.; Johnson, Bill J.; Burge, Lurinda J.; Kapil, Sanjay; Braziel, Barbara; Kautz, Kira; Reck, Amy
2009-01-01
Several tests for Bovine viral diarrhea virus (BVDV) were applied to samples collected monthly from December 20, 2005, through November 27, 2006 (day 0 to day 342) from 12 persistently infected (PI) cattle with BVDV subtypes found in US cattle: BVDV-1a, BVDV-1b, and BVDV-2a. The samples included clotted blood for serum, nasal swabs, and fresh and formalin-fixed ear notches. The tests were as follows: titration of infectious virus in serum and nasal swabs; antigen-capture (AC) enzyme-linked immunosorbent assay (ELISA), or ACE, on serum, nasal swabs, and fresh ear notches; gel-based polymerase chain reaction (PCR) testing of serum, nasal swabs, and fresh ear notches; immunohistochemical (IHC) testing of formalin-fixed ear notches; and serologic testing for BVDV antibodies in serum. Of the 12 animals starting the study, 3 died with mucosal disease. The ACE and IHC tests on ear notches had positive results throughout the study, as did the ACE and PCR tests on serum. There was detectable virus in nasal swabs from all the cattle throughout the study except for a few samples that were toxic to cell cultures. The serum had a virus titer ≥ log10 1.60 in all samples from all the cattle except for 3 collections from 1 animal. Although there were several equivocal results, the PCR test most often had positive results. The BVDV antibodies were due to vaccination or exposure to heterologous strains and did not appear to interfere with any BVDV test. These findings illustrate that PI cattle may be identified by several tests, but differentiation of PI cattle from cattle with acute BVDV infection requires additional testing, especially of blood samples and nasal swabs positive on initial testing. Also, calves PI with BVDV are continual shedders of infectious virus, as shown by the infectivity of nasal swabs over the 11-mo study. PMID:19436580
Dhaliwal, G S; Murray, R D; Dobson, H; Montgomery, J; Ellis, W A
1996-03-01
Samples of cervico-vaginal mucus from 163 bulling cows (group 1) and post calving discharges from 59 newly calved cows (group 2) in five dairy herds naturally infected with Leptospira interrogans serovar hardjo were examined for the presence of antigen and IgG and IgA antibodies by using two ELISA systems which were protein or carbohydrate based. Corresponding serum samples were examined for systemic immune responses by using a microscopic agglutination test (MAT) and IgG-ELISA tests. Antigen was detected by direct immunofluorescence in six of the 163 samples of cervico-vaginal mucus. Both IgG and IgA antibodies were detected by ELISA in the genital discharges with a prevalence much higher than that obtained by the MAT but lower than that observed with the serum IgG-ELISA. Combining both groups, none of the MAT-positive cattle was negative by serum-ELISA. By using the protein or carbohydrate fraction serum IgG-ELISA assays, respectively, 29 or 41 per cent of the MAT-negative cows were positive at a titre of at least 1:40. Similarly, eight or 23 samples (10 or 27 per cent) had titres of at least 1:20 in the genital discharge ELISA for IgG and IgA antibodies, respectively. The serum IgG-ELISA was the most efficient in detecting hardjo antibodies, but in group 2 the IgG- and IgA-ELISA of the post calving discharge proved to be equally effective.
Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein
2015-03-01
Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.
Serum proteomics reveals systemic dysregulation of innate immunity in type 1 diabetes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Qibin; Fillmore, Thomas L.; Schepmoes, Athena A.
Using global liquid chromatography-mass spectrometry (LC-MS)-based proteomics analyses, we identified 24 serum proteins significantly variant between those with type 1 diabetes and healthy controls. Functionally, these proteins represent innate immune responses, the activation cascade of complement, inflammatory responses and blood coagulation. Targeted verification analyses were performed on 52 surrogate peptides representing these proteins with serum samples from an antibody standardization program cohort of 100 healthy control and 50 type 1 diabetic subjects, and 16 peptides were verified having very good discriminating power, with areas under the receiver operator characteristic curve ≥ 0.8. Further validation with blinded serum samples from anmore » independent cohort (10 healthy control and 10 type 1 diabetic) demonstrated that peptides from platelet basic protein and C1 inhibitor achieved both 100% sensitivity and 100% specificity for classification of samples. The disease specificity of these proteins was assessed using serum from 50 age matched type 2 diabetic individuals, and a subset of proteins, particularly C1 inhibitor were exceptionally good discriminators between these two forms of diabetes. The panel of biomarkers distinguishing those with type 1 diabetes from healthy control and type 2 diabetes suggests dysregulated innate immune responses may be associated with the development of this disorder.« less
Scarano, S; Scuffi, C; Mascini, M; Minunni, M
2011-11-30
Only few papers deal with Surface Plasmon Resonance imaging (SPRi) direct detection on complex matrices, limiting the biosensor application to real analytical problems. In this work a SPRi biosensor for anti-bovine IgG detection in untreated human bodily fluids, i.e. diluted human serum and milk, was developed. Enhanced levels of cow's milk antibodies in children's serum are suspected for their possible correlation with Type 1 diabetes during childhood and their detection in real samples was up to now performed by classical immunoassays based on indirect detection. The biosensor was optimised in standard samples and then in untreated human milk for anti-bovine IgG direct detection. The key novelty of the work is the evaluation of matrix effect by applying to real samples an experimental and ex ante method previously developed for SPRi signal sampling in standard solutions, called "Data Analyzer"; it punctually visualises and analyses the behaviour of receptor spots of the array, to select only spot areas with the best specific vs. unspecific signal values. In this way, benefits provide by SPRi image analysis are exploited here to quantify and minimise drawbacks due to the matrix effect, allowing to by-pass every matrix pre-treatment except dilution. Copyright © 2011 Elsevier B.V. All rights reserved.
Human serum miR-34a as an indicator of exposure to ionizing radiation.
Halimi, Mohammad; Shahabi, Ahmad; Moslemi, Dariush; Parsian, Hadi; Asghari, S Mohsen; Sariri, Reyhaneh; Yeganeh, Farshid; Zabihi, Ebrahim
2016-11-01
Radiation exposure in industrial accidents or nuclear device attacks is a major public health concern. There is an urgent need for markers that rapidly identify people exposed to ionizing radiation (IR). Finding a blood-based marker is advantageous because of the ease of sample collection. This study was designed to test the hypothesis that serum miR-34a could serve as an indicator of exposure to IR. Therefore, 44 women with breast cancer, where radiotherapy was part of their therapeutic protocol, were investigated in this study. After demonstrating the appropriateness of our microRNA (miRNA) extraction efficiency and miRNA assay in human serum, we analyzed the miR-34a level in paired serum samples before and after radiotherapy. Fifty Gy X-ray irradiation in daily dose fractions of 2 Gy, 5 days per week, was used in this study. We demonstrated that IR significantly increased serum level of miR-34a. By measuring miR-34a in serum, we could distinguish irradiated patients with sensitivity of 65 % and specificity of 75 %. According to this study, serum miR-34a has the potential to be used as an indicator of radiation exposure.
Wiener, Carolina David; de Mello Ferreira, Sharon; Pedrotti Moreira, Fernanda; Bittencourt, Guilherme; de Oliveira, Jacqueline Flores; Lopez Molina, Mariane; Jansen, Karen; de Mattos Souza, Luciano Dias; Rizzato Lara, Diogo; Portela, Luiz Valmor; da Silva, Ricardo Azevedo; Oses, Jean Pierre
2015-09-15
Nerve growth factor (NGF) is an important member of the neurotrophins group and their involvement in the pathophysiology of major depression disorder (MDD) and suicide risk (SR) has been recently suggested. The aim of this study is to evaluate the changes in NGF serum levels in individuals with MDD and with or without risk of suicide, in subjects from a young population-based sample. This is a paired cross-sectional study nested in a population-based study. Individuals were rated for MDD and SR by a diagnostic interview--Mini International Neuropsychiatric Interview (M.I.N.I). The total population of the sample was comprised of 141 subjects distributed in three groups: 47 healthy controls, 47 subjects with current depressive episode without SR (MDD) and 47 subjects with current depressive episode and with SR (MDD + SR). NGF serum levels were significantly reduced in the MDD and MDD + SR groups when compared with controls (p ≤ 0.001). However, there were no differences in NGF levels between the MDD and MDD + SR groups (p = 1.000). These results suggest that reduced NGF serum levels can be a possible biomarker of MDD. Copyright © 2015 Elsevier B.V. All rights reserved.
microRNA-371a-3p as informative biomarker for the follow-up of testicular germ cell cancer patients.
van Agthoven, Ton; Eijkenboom, Wil M H; Looijenga, Leendert H J
2017-08-01
α-fetoprotein (AFP) and human chorionic gonadotropin subunit beta (B-HCG) are informative serum biomarkers for the primary diagnosis and follow-up of testicular germ cell cancer (TGCC) patients. About 20% of TGCC patients with a non-seminoma (NS) and about 80% with a seminoma (SE) are, however, negative for these biomarkers. Embryonic stem cell microRNAs (miRs) may serve as promising alternative serum biomarkers. Here we investigated a retrospective series of serum samples from selected TGCC patients who developed a relapse in time to test the possible additional value of the serum-based ampTSmiR test compared to the conventional serum-based protein biomarkers for follow-up. We investigated 261 retrospective serum samples of six selected fully evaluated TGCC patients with a proven relapse using the ampTSmiR test for miR-371a-3p, miR-373-3p, and miR-367-3p and compared the results to those of the conventional protein biomarkers. At primary diagnosis, elevated serum B-HCG, AFP and LDH levels were found to be informative in 4/6, 3/6 and 3/6 patients, respectively. At primary diagnosis the levels of miR-371a-3p and miR-373-3p were elevated in 4/4, and miR-367-3p in 3/4 patients. For two cases no starting serum sample was available for retrospective miR analysis. Residual disease (overlooked by histopathological examination) was detected in one case by miR-371a-3p only. The miR-371a-3p level was increased in one patient two months before detection of an intracranial metastasis. B-HCG was informative in 3/4 and the ampTSmiR test in 4/4 patients with a relapse or residual disease. None of the biomarkers were informative for the detection of residual mature teratoma. The ampTSmiR test is more sensitive than the conventional TGCC protein biomarkers for the detection of residual disease and relapse, excluding mature teratoma.
Zhao, Xuemei; Bender, Florent; Shukla, Rajiv; Kang, John J; Caro-Aguilar, Ivette; Laterza, Omar F
2016-04-01
Pathogenic Clostridium difficile produces two proinflammatory exotoxins, toxin A and toxin B. Low level of serum antitoxin IgG antibodies is a risk factor for the development of primary and recurrent C. difficile infection (CDI). We developed and validated two sensitive, titer-based electrochemiluminescence assays for the detection of serum antibody levels against C. difficile toxins A and B. These assays demonstrated excellent precision. The sensitivity of the assays allowed the detection of antitoxin A and antitoxin B IgG antibodies in all tested serum samples during assay validation. The validated titer-based assays enable assessment of antitoxin A and antitoxin B IgG antibodies as potential biomarkers to identify patients with CDI at increased risk for CDI recurrence.
Improved LC-MS/MS method for the quantification of hepcidin-25 in clinical samples.
Abbas, Ioana M; Hoffmann, Holger; Montes-Bayón, María; Weller, Michael G
2018-06-01
Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the "sticky" character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing a LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend a LC-MS/MS-based quantification method with a dynamic range of 0.5-40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials. Graphical abstract Structure of hepcidin-25 (Protein Data Bank, PDB ID 2KEF).
Jemima, Ebenezer Angel; Manoharan, Seeralan; Kumanan, Kathaperumal
2014-08-01
The measurement of neutralizing antibodies induced by the glycoprotein of rabies virus is indispensable for assessing the level of neutralizing antibodies in animals or humans. A rapid fluorescent focus inhibition test (RFFIT) has been approved by WHO and is the most widely used method to measure the virus-neutralizing antibody content in serum, but a rapid test system would be of great value to screen large numbers of serum samples. To develop and evaluate a latex agglutination test (LAT) for measuring rabies virus antibodies, a recombinant glycoprotein was expressed in an insect cell system and purified, and the protein was coated onto latex beads at concentrations of 0.1, 0.25, 0.5, 0.75, and 1 mg/ml to find out the optimal concentration for coating latex beads. It was found that 0.5 mg/ml of recombinant protein was optimal for coating latex beads, and this concentration was used to sensitize the latex beads for screening of dog serum samples. Grading of LAT results was done with standard reference serum with known antibody titers. A total of 228 serum samples were tested, out of which 145 samples were positive by both RFFIT and LAT, and the specificity was found to be 100 %. In RFFIT, 151 samples were positive, the sensitivity was found to be 96.03 %, and the accuracy/concordance was found to be 97.39 %. A rapid field test-a latex agglutination test (LAT)-was developed and evaluated for rabies virus antibody assessment using recombinant glycoprotein of rabies virus expressed in an insect cell system.
Long-term in vitro reactivity for HLA antibodies and comparison of detection using serum vs. plasma
Norris, Philip J.; Lee, Jar-How; Carrick, Danielle M.; Gottschall, Jerome L.; Lebedeva, Mila; de Castro, B.R.; Kleinman, Steven H.; Busch, Michael P.
2010-01-01
BACKGROUND HLA antibodies are a possible cause of transfusion-related acute lung injury (TRALI), and fluorescent bead assays are often used for antibody detection. Serum is the manufacturer’s recommended sample, but plasma may be easier to obtain for studies of HLA antibody prevalence and TRALI case investigations. STUDY DESIGN AND METHODS Specimens were obtained from 44 multiparous females positive for HLA antibodies by lymphocytotoxicity testing at least 13 years prior, and from 1,000 contemporary blood donors. Screening tests were performed using a Luminex-based assay. In addition to comparing results obtained with paired plasma and serum samples, the effects of storage at 4 °C for one week and of multiple freeze-thaw cycles were evaluated. RESULTS Of 42 evaluable subjects with HLA antibodies documented >13 years earlier, only 1 showed loss of detectable antibodies, with 39 (93%) positive in the screening assay for class I and 24 (57%) positive in the screening assay for HLA class II antibodies. In 968 evaluable contemporary donors, 291 screened positive for HLA class I and 206 for HLA class II antibodies using a low assay cut-off. Screening test concordance using paired plasma and serum samples was high, particularly for subjects with higher level antibodies. Refrigeration of samples for one week did not significantly affect assay results, while repeated freeze-thaw cycles caused a decrement in signal level. CONCLUSION Serum and plasma samples gave concordant results in the majority of cases, particularly for specimens with higher-level antibodies. High-level HLA antibodies were present in most individuals for over 13 years. PMID:18980615
Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi
2014-01-20
Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV <1%. A certified reference material (CRM) of lipids in frozen human serum was used to verify the accuracy of the measurement. The obtained values for both triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation <0.4% from the certified values. The relative expanded uncertainties were also comparable with the uncertainties associated with the certified values of the CRM. The validated procedure was used in an External Quality Assessment (EQA) Program organized by our laboratory to establish the assigned values for triglycerides and total glycerides.
Springer, Jan; Morton, C. O.; Perry, Michael; Heinz, Werner J.; Paholcsek, Melinda; Alzheimer, Mona; Rogers, T. R.; Barnes, Rosemary A.; Einsele, Hermann; White, P. Lewis
2013-01-01
Samples from patients at high risk for invasive aspergillosis (IA) were prospectively collected and analyzed for the presence of molecular markers of fungal infection. Serum specimens were screened for galactomannan and Aspergillus DNA, and whole-blood specimens were screened only for Aspergillus DNA. Fungal infections were categorized according to the European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group, National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) criteria. Forty-seven cases (proven and probable IA) and 31 controls (no evidence of IA) were selected retrospectively for this case-control study, comprising 803 samples, in order to determine the performance of whole-blood PCR, serum PCR, and serum galactomannan testing. Although no single assay was able to detect every case of IA, a combination of different assays provided the best performance. There was no significant difference between the use of whole-blood and serum specimens for PCR-based diagnosis of IA, but there was a trend for whole blood to be more sensitive (85% versus 79%) and to yield an earlier positive result (36 days versus 15 days) than for serum. However, DNA extraction from serum specimens is easier and faster than that from whole-blood specimens, and it allows the same specimen to be used for both galactomannan and PCR assays. In conclusion, the appropriate sample type for DNA extraction should be determined by the local requirements and the technical platforms available at each individual center. A combination of biomarker tests offered the best diagnostic utility for detecting IA. PMID:23426930
Massuger, L F; Thomas, C M; Segers, M F; Corstens, F H; Verheijen, R H; Kenemans, P; Poels, L G
1992-11-01
The development of human anti-mouse antibodies (HAMA) may cause problems in radioimmunotargeting studies, but may also improve survival of patients. To identify the presence of HAMA in blood samples from patients intravenously injected with 1 mg of 111In-labeled OV-TL3-F(ab')2, we developed three specific OV-TL 3-based HAMA assays and tested these along with two commercially available nonspecific HAMA assays (Sorin and Immunomedics). The specific assays were positive for HAMA with 10 postinjection serum samples from 7 patients. Eight of the 10 samples were also HAMA positive with one or both nonspecific HAMA assays. Conflicting results were observed with half the number of samples. The two nonspecific assays also reacted positively with another 11 serum samples from 5 patients including their preinjection samples. Despite some contradictory results, the nonspecific HAMA assays identify both pre-existent and Mab-induced HAMA, whereas the specific OV-TL3-based HAMA assays identify specific immune-responses occurring after the OV-TL 3 injection.
Collicutt, Nancy B; Garner, Bridget; Berghaus, Roy D; Camus, Melinda S; Hart, Kelsey
2015-03-01
Although delays between blood sample collection and analysis are common in veterinary medicine, the effect of prolonged serum-clot contact time on serum glucose concentration is not well established and species differences have not been elucidated. The objective was to investigate the effect of storage time and temperature on serum glucose concentration in stored whole blood samples from horse, dog, alpaca, and sturgeon. Whole blood specimens were divided into 7 no-additive tubes and serum was separated from one sample within one hour, serving as the reference sample. The remaining samples were stored at 4°C and 25°C, then centrifuged and serum glucose measured by automated analysis at 2, 4, and 8 hours postcollection. Glucose concentrations were compared using linear mixed models. The decline in serum glucose concentration for all samples stored at 4°C was not statistically significant, except for the 8-hour samples from sturgeon and dog. At 25°C, serum glucose concentration was comparable to reference values at 2 hours in sturgeon and alpaca, but significantly lower at 4 and 8 hours in those species, and at all time points in equine and canine specimens, being most prominent after 8 hours of storage in canine specimens. Storage at 4°C limits serum glucose decline for at least 4 hours in all species tested and up to 8 hours in specimens of horse and alpaca. At 25°C, serum-clot contact time should not exceed 1 hour in equine and canine samples, and 2 hours in specimens from alpaca and sturgeon. © 2014 American Society for Veterinary Clinical Pathology.
Influenza A Virus Surveillance Based on Pre-Weaning Piglet Oral Fluid Samples.
Panyasing, Y; Goodell, C; Kittawornrat, A; Wang, C; Levis, I; Desfresne, L; Rauh, R; Gauger, P C; Zhang, J; Lin, X; Azeem, S; Ghorbani-Nezami, S; Yoon, K-J; Zimmerman, J
2016-10-01
Influenza A virus (IAV) surveillance using pre-weaning oral fluid samples from litters of piglets was evaluated in four ˜12 500 sow and IAV-vaccinated, breeding herds. Oral fluid samples were collected from 600 litters and serum samples from their dams at weaning. Litter oral fluid samples were tested for IAV by virus isolation, quantitative reverse transcription-polymerase chain reaction (qRT-PCR), RT-PCR subtyping and sequencing. Commercial nucleoprotein (NP) enzyme-linked immunosorbent assay (ELISA) kits and NP isotype-specific assays (IgM, IgA and IgG) were used to characterize NP antibody in litter oral fluid and sow serum. All litter oral fluid specimens (n = 600) were negative by virus isolation. Twenty-five oral fluid samples (25/600 = 4.2%) were qRT-PCR positive based on screening (Laboratory 1) and confirmatory testing (Laboratory 2). No hemagglutinin (HA) and neuraminidase (NA) gene sequences were obtained, but matrix (M) gene sequences were obtained for all qRT-PCR-positive samples submitted for sequencing (n = 18). Genetic analysis revealed that all M genes sequences were identical (GenBank accession no. KF487544) and belonged to the triple reassortant influenza A virus M gene (TRIG M) previously identified in swine. The proportion of IgM- and IgA-positive samples was significantly higher in sow serum and litter oral fluid samples, respectively (P < 0.01). Consistent with the extensive use of IAV vaccine, no difference was detected in the proportion of IgG- and blocking ELISA-positive sow serum and litter oral fluids. This study supported the use of oral fluid sampling as a means of conducting IAV surveillance in pig populations and demonstrated the inapparent circulation of IAV in piglets. Future work on IAV oral fluid diagnostics should focus on improved procedures for virus isolation, subtyping and sequencing of HA and NA genes. The role of antibody in IAV surveillance remains to be elucidated, but longitudinal assessment of specific antibody has the potential to provide information regarding patterns of infection, vaccination status and herd immunity. © 2014 Blackwell Verlag GmbH.
Carrasco, Juan Antonio Péculo; Escorza, Juana Gómez; Sánchez, María Del Mar Casal; Bouza, Mónica Rodríguez; Sanchez, José Luis Avecilla; Ruiz, Hugo José Rodríguez
2008-01-01
The authors detail the characteristics for the sterility of drained serums placed in a mobile emergency service unit and they determine how much time they can maintain optimum conditions for the use of these serums by means of a controlled, random, triple blind clinical test in which the units studied were serums prepared by an infusion system and a three-way valve. Data were gathered during a 12 month study period. The authors designed six operating groups based on their exposure time and where they were kept. These samples totaled 672 units. The authors carried out 12 microbiological cultural analyses for each unit; these analyses were tested for bacteria and fungi, both aerobic and anaerobic. The authors contrasted their hypothesis with a multivariable logistic regression model used as the variable for sterility A value of p < 0.05 was considered to be significant. Results were obtained on 669 serums, 98.82% of samples. Colonization was found in 1.7% of the 8028 cultures analyzed; in only 2 cases was there a register greater than 10 UFC/ml. This colonization corresponded to 103 serums which were then classified as non-sterile. For sterility the logistic regression model did not show any significant association with the various operating groups, which were controlled by means of two possible variable methods. The authors did not find evidence that recently drained serums were different, from the point of view of sterility, than the serums exposed during 24, 48 or 72 hours but, as well as for the groups, the incidences of these serums tripled the risk of colonization. The authors concluded they could use serums prepared previously and these serums sterility were guaranteed to the same degree as recently drained serums.
Rauf, Sana; Zhang, Ling; Ali, Asghar; Liu, Yang; Li, Jinghong
2017-02-24
Detection of very low amounts of illicit drugs such as cocaine in clinical fluids like serum continues to be important for many areas in the fight against drug trafficking. Herein, we constructed a label-free nanopore biosensor for rapid and highly sensitive detection of cocaine in human serum and saliva samples based on target-induced strand release strategy. In this bioassay, an aptamer for cocaine was prehybridized with a short complementary DNA. Owing to cocaine specific binding with aptamer, the short DNA strand was displaced from aptamer and translocation of this output DNA through α-hemolysin nanopore generated distinct spike-like current blockages. When plotted in double-logarithmic scale, a linear relationship between target cocaine concentration and output DNA event frequency was obtained in a wide concentration range from 50 nM to 100 μM of cocaine, with the limit of detection down to 50 nM. In addition, this aptamer-based sensor method was successfully applied for cocaine detection in complex biological fluids like human saliva and serum samples with great selectivity. Simple preparation, low cost, rapid, label-free, and real sample detection are the motivating factors for practical application of the proposed biosensor.
Micromethod for phosphonoformate inhibition assay of hepatitis B viral DNA polymerase.
Lin, H J; Wu, P C; Lai, C L; Chak, W
1984-04-01
A micromethod for the specific measurement of hepatitis B viral DNA polymerase in serum is presented, based on the phosphonoformate inhibition assay (J Med Virol 12: 61-70, 1983). In the micromethod, sample volume is reduced to 120 microL and the ultracentrifugation step is eliminated. The method allows good discrimination between serum infected with hepatitis B virus and uninfected serum. The cutoff value for rate of nucleotide incorporation, based on assays of 41 serum specimens negative for hepatitis B serological markers, was about 15 nU/L (90th percentile). Serum containing hepatitis B surface and antigens exhibited rates of phosphonoformate-inhibitive nucleotide incorporation of 150 (SD 150) nU/L, with an upper 90th percentile range of 17 to 667 nU/L (n = 41). The micromethod makes use of commercially available [32P]dCTP (specific activity about 7000 kCi/mol). 125I-labeled dCTP was found to be unsuitable for this assay. Human DNA polymerases in serum are detected by this method but are excluded from the phosphonoformate-inhibitive fraction.
Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.
Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H
2013-10-01
Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.
Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc
1998-01-01
A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372
Sukla, Soumi; Ghosh, Anisa; Saha, Rajdeep; De, Abhishek; Adhya, Samit; Biswas, Subhajit
2018-06-13
Zika virus infections have recently been reported in many dengue-endemic areas globally. Both dengue (DENV) and Zika (ZIKV) virus are transmitted by Aedes mosquitoes, raising the possibility of mixed infections in both vector and host. We evaluated DENV and ZIKV prevalence in human and vector samples in Kolkata, a DENV-endemic city. Blood samples were collected from 70 patients presenting dengue-like fever symptoms at a hospital in Kolkata during 2015-16. Serum was obtained and tested for DENV infection by DENV NS1-based ELISA. Adult (n=8) and larval stages (n=12) of Aedes were also collected. A RT-PCR-based screening of both viruses supplemented by amplicon sequencing was performed. Of the 70 samples, 20 DENV NS1-positive serum samples were used for detailed molecular study for DENV infection. Eighteen of these (90 %) were positive by hemi-nested serotype-specific RT-PCR for DENV1/2/3, with four samples showing evidence of DENV2-3 or DENV1-3 mixed infection. None were ZIKV-positive using NS5 or ENV-based PCR, though weak amplification of a DENV1 NS5 sequence was detected in three serum samples indicating cross-reactivity of the primers. All mosquito samples were ZIKV-negative, whereas 5/8 (63 %) of adult mosquitoes and 11/12 (92 %) of larvae were DENV3-positive. Both host and vector samples showed absence of ZIKV but high prevalence of DENV. The high rate of infection of larvae with DENV is suggestive of trans-ovarial transmission that could contribute to the surge of human infections during each post-monsoon season. It would be important to guard against false positives using the available Zika-reporting primer sets.
Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen
2016-03-01
Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time to diagnosis may be enhanced by testing multiple contemporaneously obtained sample types. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Bjermo, Helena; Aune, Marie; Cantillana, Tatiana; Glynn, Anders; Lind, P Monica; Ridefelt, Peter; Darnerud, Per Ola
2017-01-01
The aim of this study was to investigate associations between serum concentrations of brominated flame retardants and personal characteristics, including diet, in adults participating in a population-based study in Sweden 2010-11. Moreover, observed concentrations were used in a health risk assessment, using published health-based reference values. Serum samples of 170 adult individuals of both sexes were analyzed for 10 PBDE congeners and HBCD by GC-MS. When including concentrations between LOD and LOQ, highest median serum concentration was observed for BDE-153 (1.2 ng/g serum lipid), followed by BDE-209 (0.95 ng/g lipid), BDE-47 (0.49 ng/g lipid) and BDE-100 (0.21 ng/g lipid). Median concentration of HBCD was 0.10 ng/g lipid. A few markedly elevated concentrations of BDE-209, HBCD (77-78 ng/g lipid) and BDE-47 (44 ng/g lipid) were observed. The only statistical significant findings were higher BDE-153 concentrations in men than in women, and positive associations between serum BDE-153 concentrations and consumption of fish (total), beef, mutton and poultry. PBDE concentrations were in accordance with concentrations reported in other European countries but generally lower than those found in North America. Median PBDE serum concentrations observed in adults from Sweden suggest sufficient health protection, when compared with published health-based reference values, although some outliers with high serum concentrations had lower safety margins. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Comparison of Schmallenberg virus antibody levels detected in milk and serum from individual cows.
Daly, Janet M; King, Barnabas; Tarlinton, Rachael A; Gough, Kevin C; Maddison, Ben C; Blowey, Roger
2015-03-11
Schmallenberg virus (SBV) is a recently emerged virus of ruminants in Europe. Enzyme-linked immunosorbent assays (ELISA) are commonly used to detect SBV-specific antibodies in bulk tank milk samples to monitor herd exposure to infection. However, it has previously been shown that a bulk tank milk sample can test positive even though the majority of cows within the herd are seronegative for SBV antibodies. Development of a pen-side test to detect antibodies in individual milk samples would potentially provide a cheaper test (for which samples are obtained non-invasively) than testing individual serum samples by ELISA. Therefore, the aim of this study was to investigate the agreement between antibody levels measured in milk and serum. Corresponding milk and serum samples from 88 cows in two dairy herds in the UK were tested for presence of immunoglobulin G antibodies to SBV using a commercially-available indirect ELISA. A serum neutralisation test (NT) was also performed as a gold standard assay. The ELISA values obtained for the bulk tank milk samples corresponded with the mean values for individual milk samples from each herd (bulk tank milk values were 58% and 73% and mean individual milk values 50% and 63% for herds A and B, respectively). Of the 88 serum samples tested in the NT, 82 (93%) were positive. Although at higher antibody levels, the ELISA values tended to be higher for the individual milk samples than for the corresponding serum samples, the positive predictive value for milk samples was 98% and for serum samples 94%. The serum ELISA was more likely to give false positive results around the lower cut-off value of the assay. The results indicate that testing of individual milk samples for antibodies against SBV by ELISA could be used to inform decisions in the management of dairy herds such as which, if any, animals to vaccinate.
Association between Nitrogen Stable Isotope Ratios in Human Hair and Serum Levels of Leptin.
Ahn, Song Vogue; Koh, Sang-Baek; Lee, Kwang-Sik; Bong, Yeon-Sik; Park, Jong-Ku
2017-10-01
Stable isotope ratios have been reported to be potential biomarkers of dietary intake and nutritional status. High serum levels of leptin, a hormone which regulates energy metabolism and food intake, are associated with insulin resistance and metabolic syndrome. However, little is known about the association between stable isotope ratios and the metabolic risk in humans. We investigated whether the carbon and nitrogen stable isotope ratios in hair are associated with serum leptin levels. Hair samples were collected from 399 healthy adults (233 men and 166 women) aged 40 to 70 years of a community-based cohort in Korea and the bulk stable isotope ratios of carbon (δ 13 C) and nitrogen (δ 15 N) were measured for all hair samples. Serum leptin levels were analyzed by radioimmunoassay. δ 15 N showed positive correlations with serum leptin levels. In multivariate models, increasing δ 15 N were associated with elevated serum leptin levels (defined as ≥ the median values), whereas δ 13 C were not significantly associated with serum leptin levels. The odds ratio (95% confidence interval) per 1‰ increase in δ 15 N for an elevated serum leptin level was 1.58 (1.11-2.26). In participants with high body mass index, δ 15 N showed positive associations with serum leptin levels, whereas these associations were not seen in participants with low body mass index. The nitrogen stable isotopic ratio in hair is positively associated with serum leptin levels. The hair δ 15 N could be used as a clinical marker to estimate metabolic risk.
Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin
2014-01-01
Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.
Dukić, Lora; Šimundić, Ana-Maria; Malogorski, Davorin
2014-01-01
Introduction: Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Materials and methods: Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Results: Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Conclusion: Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration. PMID:24627723
NASA Astrophysics Data System (ADS)
Brazhnik, Kristina; Grinevich, Regina; Efimov, Anton E.; Nabiev, Igor; Sukhanova, Alyona
2014-05-01
Advanced multiplexed assays have recently become an indispensable tool for clinical diagnostics. These techniques provide simultaneous quantitative determination of multiple biomolecules in a single sample quickly and accurately. The development of multiplex suspension arrays is currently of particular interest for clinical applications. Optical encoding of microparticles is the most available and easy-to-use technique. This technology uses fluorophores incorporated into microbeads to obtain individual optical codes. Fluorophore-encoded beads can be rapidly analyzed using classical flow cytometry or microfluidic techniques. We have developed a new generation of highly sensitive and specific diagnostic systems for detection of cancer antigens in human serum samples based on microbeads encoded with fluorescent quantum dots (QDs). The designed suspension microarray system was validated for quantitative detection of (1) free and total prostate specific antigen (PSA) in the serum of patients with prostate cancer and (2) carcinoembryonic antigen (CEA) and cancer antigen 15-3 (CA 15-3) in the serum of patients with breast cancer. The serum samples from healthy donors were used as a control. The antigen detection is based on the formation of an immune complex of a specific capture antibody (Ab), a target antigen (Ag), and a detector Ab on the surface of the encoded particles. The capture Ab is bound to the polymer shell of microbeads via an adapter molecule, for example, protein A. Protein A binds a monoclonal Ab in a highly oriented manner due to specific interaction with the Fc-region of the Ab molecule. Each antigen can be recognized and detected due to a specific microbead population carrying the unique fluorescent code. 100 and 231 serum samples from patients with different stages of prostate cancer and breast cancer, respectively, and those from healthy donors were examined using the designed suspension system. The data were validated by comparing with the results of the "gold standard" enzyme-linked immunosorbent assay (ELISA). They have shown that our approach is a good alternative to the diagnostics of cancer markers using conventional assays, especially in early diagnostic applications.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10523. (5) Use sterile deionized distilled water to reconstitute penicillin. (6) Sterile serum should be... samples (ml)—5.0 (1:2000) Mycoplasma Broth Base (g)—22.5 Aqueous penicillin (units)—500,000 Sterile serum... Aqueous penicillin (units)—400,000 NAD (ml)—12.5 Cysteine hydrochloride (ml)—12.5 (1) Rotate flask gently...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10523. (5) Use sterile deionized distilled water to reconstitute penicillin. (6) Sterile serum should be... samples (ml)—5.0 (1:2000) Mycoplasma Broth Base (g)—22.5 Aqueous penicillin (units)—500,000 Sterile serum... Aqueous penicillin (units)—400,000 NAD (ml)—12.5 Cysteine hydrochloride (ml)—12.5 (1) Rotate flask gently...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10523. (5) Use sterile deionized distilled water to reconstitute penicillin. (6) Sterile serum should be... samples (ml)—5.0 (1:2000) Mycoplasma Broth Base (g)—22.5 Aqueous penicillin (units)—500,000 Sterile serum... Aqueous penicillin (units)—400,000 NAD (ml)—12.5 Cysteine hydrochloride (ml)—12.5 (1) Rotate flask gently...
2006-09-01
Specific examples using serum samples from prostate cancer and hepatocellular carcinoma subjects are provided, along with suggested experimental...from prostate cancer and hepatocellular carcinoma subjects are provided, along with suggested experimental strategies for integration of lectin based...application of different lectins to enrich for serum glycoforms found in sera from prostate cancer and hepatocellular carcinoma subjects. For the
NASA Astrophysics Data System (ADS)
Duarte, Janaína; Pacheco, Marcos T. T.; Villaverde, Antonio Balbin; Machado, Rosangela Z.; Zângaro, Renato A.; Silveira, Landulfo
2010-07-01
Toxoplasmosis is an important zoonosis in public health because domestic cats are the main agents responsible for the transmission of this disease in Brazil. We investigate a method for diagnosing toxoplasmosis based on Raman spectroscopy. Dispersive near-infrared Raman spectra are used to quantify anti-Toxoplasma gondii (IgG) antibodies in blood sera from domestic cats. An 830-nm laser is used for sample excitation, and a dispersive spectrometer is used to detect the Raman scattering. A serological test is performed in all serum samples by the enzyme-linked immunosorbent assay (ELISA) for validation. Raman spectra are taken from 59 blood serum samples and a quantification model is implemented based on partial least squares (PLS) to quantify the sample's serology by Raman spectra compared to the results provided by the ELISA test. Based on the serological values provided by the Raman/PLS model, diagnostic parameters such as sensitivity, specificity, accuracy, positive prediction values, and negative prediction values are calculated to discriminate negative from positive samples, obtaining 100, 80, 90, 83.3, and 100%, respectively. Raman spectroscopy, associated with the PLS, is promising as a serological assay for toxoplasmosis, enabling fast and sensitive diagnosis.
Hou, Siyuan; Riley, Christopher B; Mitchell, Cynthia A; Shaw, R Anthony; Bryanton, Janet; Bigsby, Kathryn; McClure, J Trenton
2015-09-01
Immunoglobulin G (IgG) is crucial for the protection of the host from invasive pathogens. Due to its importance for human health, tools that enable the monitoring of IgG levels are highly desired. Consequently there is a need for methods to determine the IgG concentration that are simple, rapid, and inexpensive. This work explored the potential of attenuated total reflectance (ATR) infrared spectroscopy as a method to determine IgG concentrations in human serum samples. Venous blood samples were collected from adults and children, and from the umbilical cord of newborns. The serum was harvested and tested using ATR infrared spectroscopy. Partial least squares (PLS) regression provided the basis to develop the new analytical methods. Three PLS calibrations were determined: one for the combined set of the venous and umbilical cord serum samples, the second for only the umbilical cord samples, and the third for only the venous samples. The number of PLS factors was chosen by critical evaluation of Monte Carlo-based cross validation results. The predictive performance for each PLS calibration was evaluated using the Pearson correlation coefficient, scatter plot and Bland-Altman plot, and percent deviations for independent prediction sets. The repeatability was evaluated by standard deviation and relative standard deviation. The results showed that ATR infrared spectroscopy is potentially a simple, quick, and inexpensive method to measure IgG concentrations in human serum samples. The results also showed that it is possible to build a united calibration curve for the umbilical cord and the venous samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Manchala, Nageswar Reddy; Dungdung, Ranjeet; Pilankatta, Rajendra
2017-10-01
Human serum protein profiling of the individual infected with multiple dengue virus serotypes for identifying the potential biomarkers and to investigate the cause for the severity of dengue virus infection. Dengue virus NS1-positive serum samples were pooled into two groups (S2 and S3) based on the molecular serotyping and number of heterotypic infections. The pooled serum samples were subjected to two-dimensional gel electrophoresis (2DGE) to identify the differentially expressed proteins. The peptide masses of upregulated protein were detected by matrix-assisted laser desorption-ionisation time-of-flight MALDI-TOF mass spectrometry and analysed by MASCOT search engine. The results were compared with the control group (S1). The commonly upregulated protein was validated by quantitative ELISA and compared with control as well as single serotypic infected samples. Based on 2DGE, total thirteen proteins were differentially upregulated in S2 and S3 groups as compared to control. Some of the upregulated proteins were involved in mediating the complement activation of immune response. The apolipoprotein A-1 (APO A-1) was upregulated in S2 and S3 groups. Upon validation, APO A-1 levels were increased in line with the number of heterotypic infection of dengue viruses. Heterotypic infection of dengue viruses upregulate the serum proteins involved in the complement pathway in the early phase of infection. There was a significant increase in the level of APO A-1 in three different serotypic infections of dengue virus as compared to control. Further, the role of APO-A1 can be explored in elucidating the mechanism of dengue pathogenesis. © 2017 John Wiley & Sons Ltd.
Quantification of equine immunoglobulin A in serum and secretions by a fluorescent bead-based assay.
Schnabel, Christiane L; Babasyan, Susanna; Freer, Heather; Wagner, Bettina
2017-06-01
Only few quantitative reports exist about the concentrations and induction of immunoglobulin A (IgA) in mucosal secretions of horses. Despite this, it is widely assumed that IgA is the predominant immunoglobulin on mucosal surfaces in the horse. Here, two new monoclonal antibodies (mAbs) against equine IgA, clones 84-1 and 161-1, were developed and characterized in detail. Both IgA mAbs specifically bound monomeric and dimeric equine IgA in different applications, such as Western blots and fluorescent bead-based assays. Cross-reactivity with other equine immunoglobulin isotypes was not observed. The new IgA mAb 84-1 was used in combination with the previously characterized anti-equine IgA mAb BVS2 for the development and validation of a fluorescent bead-based assay to quantify total IgA in equine serum and various secretions. The IgA assay's linear detection ranged from 64pg/ml to 1000ng/ml. For the quantification of IgA in serum or in secretions an IgA standard was purified from serum or nasal wash fluid (secretory IgA), respectively. The different standards were needed for accurate IgA quantification in the respective samples taking the different signal intensities of monomeric and dimeric IgA on the florescent bead-based assay into account. IgA was quantified by the bead-based assay established here in different equine samples of healthy adult individuals. In serum the median total IgA was 0.45mg/ml for Thoroughbred horses (TB, n=10) and 1.16mg/ml in Icelandic horses (ICH, n=12). In nasopharyngeal secretions of TB (n=7) 0.13mg/ml median total IgA was measured, and 0.25mg/ml for ICH (n=12). Saliva of ICH (n=6) contained a median of 0.15mg/ml, colostrum of Warmbloods (n=8) a median of 1.89mg/ml IgA. Compared to IgG1 and IgG4/7 quantified in the same samples, IgA appeared as the major immunoglobulin isotype in nasopharyngeal secretions and saliva while it is a minor isotype in serum and colostrum. The newly developed monoclonal antibodies against equine IgA and the resulting bead-based assay for quantification of total IgA can notably improve the evaluation of mucosal immunity in horses. Copyright © 2017 Elsevier B.V. All rights reserved.
Vasilescu, Alina; Gáspár, Szilveszter; Gheorghiu, Mihaela; David, Sorin; Dinca, Valentina; Peteu, Serban; Wang, Qian; Li, Musen; Boukherroub, Rabah; Szunerits, Sabine
2017-03-15
Lysozyme is an enzyme found in biological fluids, which is upregulated in leukemia, renal diseases as well as in a number of inflammatory gastrointestinal diseases. We present here the development of a novel lysozyme sensing concept based on the use of Micrococcus lysodeikticus whole cells adsorbed on graphene oxide (GO)-coated Surface Plasmon Resonance (SPR) interfaces. M. lysodeikticus is a typical enzymatic substrate for lysozyme. Unlike previously reported sensors which are based on the detection of lysozyme through bioaffinity interactions, the bioactivity of lysozyme will be used here for sensing purposes. Upon exposure to lysozyme containing serum, the integrity of the bacterial cell wall is affected and the cells detach from the GO based interfaces, causing a characteristic decrease in the SPR signal. This allows sensing the presence of clinically relevant concentrations of lysozyme in undiluted serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong
2017-01-01
Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime, laboratorians must remain alert to the negative interference by rheumatoid factor, and in some cases, pretreat rheumatoid factor-positive samples with blocking or absorbing reagents.
Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing
2015-01-01
Objective Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Methods Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. Results A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. Conclusion A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC. PMID:26487969
NASA Astrophysics Data System (ADS)
Wang, Ran; Huang, Shuai; Li, Jing; Chae, Junseok
2014-10-01
Thyroglobulin (Tg) is a sensitive indicator of persistent or recurrent differentiated thyroid cancer of follicular cell origin. Detection of Tg in human serum is challenging as bio-receptors, such as anti-Tg, used in immunoassay have relatively weak binding affinity. We engineer sensing surfaces using the competitive adsorption of proteins, termed the Vroman Effect. Coupled with Surface Plasmon Resonance, the "cross-responsive" interactions of Tg on the engineered surfaces produce uniquely distinguishable multiple signature patterns, which are discriminated using Linear Discriminant Analysis. Tg-spiked samples, down to 2 ng/ml Tg in undiluted human serum, are sensitively and selectively discriminated from the control (undiluted human serum).
Taheri, Salman; Jalali, Fahimeh; Fattahi, Nazir; Jalili, Ronak; Bahrami, Gholamreza
2015-10-01
Dispersive liquid-liquid microextraction based on solidification of floating organic droplet was developed for the extraction of methadone and determination by high-performance liquid chromatography with UV detection. In this method, no microsyringe or fiber is required to support the organic microdrop due to the usage of an organic solvent with a low density and appropriate melting point. Furthermore, the extractant droplet can be collected easily by solidifying it at low temperature. 1-Undecanol and methanol were chosen as extraction and disperser solvents, respectively. Parameters that influence extraction efficiency, i.e. volumes of extracting and dispersing solvents, pH, and salt effect, were optimized by using response surface methodology. Under optimal conditions, enrichment factor for methadone was 134 and 160 in serum and urine samples, respectively. The limit of detection was 3.34 ng/mmL in serum and 1.67 ng/mL in urine samples. Compared with the traditional dispersive liquid-liquid microextraction, the proposed method obtained lower limit of detection. Moreover, the solidification of floating organic solvent facilitated the phase transfer. And most importantly, it avoided using high-density and toxic solvents of traditional dispersive liquid-liquid microextraction method. The proposed method was successfully applied to the determination of methadone in serum and urine samples of an addicted individual under methadone therapy. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development of a novel protein chip for the detection of bluetongue virus in China.
Xu, Q Y; Sun, E C; Feng, Y F; Li, J P; Lv, S; Zhang, Q; Wang, H X; Zhang, J K; Wu, D L
2016-08-01
Bluetongue (BT), which is caused by the BT virus (BTV), is an important disease in ruminants that leads to significant economic losses in the husbandry industry. To detect BTV-specific antibodies in serum, a protein chip detection method based on a novel solid supporting material known as polymer-coated initiator-integrated poly (dimethyl siloxane) (iPDMS) was developed. With a threshold of 25% (signal-to-noise percentage), the sensitivity and specificity of the protein chip were 98.6% and 94.8%, respectively. Furthermore, spot serum samples obtained from six provinces of China were tested with the protein chip and a commercially available BTV enzyme-linked immunosorbent assay (ELISA) kit (IDEXX). Of 615 samples, BTV-specific antibodies were detected in 200 (32.52%) by the protein chip and in 176 (28.62%) by the IDEXX BTV ELISA kit. Comparison of the protein chip with the commercial IDEXX BTV ELISA kit yielded the following spot serum detection results: a total coincidence, a negative coincidence and a positive coincidence of 95.12%, 99.28% and 86.5%, respectively. With the protein chip, the BTV-specific serum antibody was detected in samples from all six provinces, and the positive rates ranged from 4.12 to 74.4%. These results indicate that this protein chip detection method based on iPDMS is useful for the serological diagnosis of BTV infection and for epidemiological investigation. Copyright © 2016. Published by Elsevier B.V.
Gresa-Arribas, Nuria; Titulaer, Maarten J; Torrents, Abiguei; Aguilar, Esther; McCracken, Lindsey; Leypoldt, Frank; Gleichman, Amy J; Balice-Gordon, Rita; Rosenfeld, Myrna R; Lynch, David; Graus, Francesc; Dalmau, Josep
2014-02-01
Anti-N-methyl-d-aspartate (NMDA) receptor encephalitis is a severe but treatable autoimmune disorder which diagnosis depends on sensitive and specific antibody testing. We aimed to assess the sensitivity and specificity of serum and CSF antibody testing in patients with anti-NMDA receptor encephalitis, and the relation between titres, relapses, outcome, and epitope repertoire. In this observational study, we used rat brain immunohistochemistry and cell-based assays (CBA) with fixed or live NMDA receptor-expressing cells to determine the sensitivity and specificity of antibody testing in paired serum and CSF samples. Samples were obtained at diagnosis from patients with anti-NMDA receptor encephalitis and from control participants worldwide. We deemed a patient to be antibody positive if their serum, their CSF, or both tested positive with both immunohistochemistry and CBA techniques; we determined titres with serial sample dilution using brain immunohistochemistry. We examined samples from 45 patients (25 with good outcome [modified Rankin Scale, mRS 0-2], ten with poor outcome [mRS 3-6], and ten with relapses) at three or more timepoints. We determined the epitope repertoire in the samples of 23 patients with CBA expressing GluN1-NMDA receptor mutants. We analysed samples from 250 patients with anti-NMDA receptor encephalitis and 100 control participants. All 250 patients had NMDA receptor antibodies in CSF but only 214 had antibodies in serum (sensitivity 100.0% [98.5-1000%] vs 85.6% [80.7-89.4%], p<0.0001). Serum immunohistochemistry testing was more often in agreement with CBA with fixed cells (77 [71%] of 108) than with CBA with live cells (63 [58%] of 108, p=0.0056). In multivariable analysis, CSF and serum titres were higher in patients with poor outcome than in those with good outcome (CSF dilution 340 vs 129, difference 211, [95% CI 1-421], p=0.049; serum dilution 7370 vs 1243, difference 6127 [2369-9885], p=0.0025), and in patients with teratoma than in those without teratoma (CSF 395 vs 110, difference 285 [134-437], p=0.0079; serum 5515 vs 1644, difference 3870 [548-7193], p=0.024). Over time there was a decrease of antibody titres in the 35 patients with good or poor outcome and samples followed at three timepoints regardless of outcome (from diagnosis to last follow-up: CSF 614 to 76, difference 538 [288-788]; serum 5460 to 1564, difference 3896 [2428-5362]; both p<0.0001). Relapses were associated with a change in titre more often in CSF than in serum (14 of 19 vs seven of 16, p=0.037). After recovery, 24 of 28 CSF samples and 17 of 23 serum samples from patients remained antibody positive. Patients' antibodies targeted a main epitope region at GluN1 aminoacid 369; the epitope repertoire did not differ between patients with different outcomes, and did not change during relapses. The sensitivity of NMDA receptor antibody testing is higher in CSF than in serum. Antibody titres in CSF and serum were higher in patients with poor outcome or teratoma than in patients with good outcome or no tumour. The titre change in CSF was more closely related with relapses than was that in serum. These findings emphasise the importance of including CSF in antibody studies, and that antibody titres can complement clinical assessments. Dutch Cancer Society, National Institutes of Health, McKnight Neuroscience of Brain Disorders award, the Fondo de Investigaciones Sanitarias, ErasmusMC fellowship, and Fundació la Marató de TV3. Copyright © 2014 Elsevier Ltd. All rights reserved.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-09-24
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70-200 mg/dL), revealing high system performance for a wide glycemic state range (45-500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting.
A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies
Jobard, Elodie; Trédan, Olivier; Postoly, Déborah; André, Fabrice; Martin, Anne-Laure; Elena-Herrmann, Bénédicte; Boyault, Sandrine
2016-01-01
The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation) and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies. PMID:27929400
Specific IgA and IgG antibodies in paired serum and breast milk samples in human strongyloidiasis.
Mota-Ferreira, Daniela M L; Gonçalves-Pires, Maria do Rosário F; Júnior, Alvaro Ferreira; Sopelete, Mônica C; Abdallah, Vânia O S; Costa-Cruz, Julia M
2009-02-01
Strongyloidiasis, caused by the nematode Strongyloides stercoralis, is one of the major worldwide parasitic infections in humans. Breastfeeding may offer a potential protection against this infection. Feces, serum and milk samples were obtained from 90 lactating women from Clinical Hospital of Universidade Federal de Uberlândia, Brazil. The fecal samples were collected for parasitological diagnosis and the serum and milk samples were examined for specific S. stercoralis IgA and IgG antibodies using the indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assay (ELISA). Fecal examination showed that the rate of prevalence of S. stercoralis infection in the lactating women was 4.4%. IFAT manifested a 16.7% positivity rate for specific IgA antibody in serum and a 28.9% rate in milk samples; specific IgG was 41.1% in serum and 25.5% in milk samples. According to ELISA the positivity rate for specific IgA antibody was 21.1% in serum and 42.2% in milk samples; specific IgG was 40% in serum and 18.9% in milk samples. In serum samples, these immunological tests showed a concurrence of 91.1% and 94.4%, respectively, in detecting specific IgA and IgG antibodies. In milk samples, they showed a concurrence of 70% and 78.9%, respectively, in detecting specific IgA and IgG antibodies. There was a statistically significant difference between concordant and discordant results of immunological tests (P<0.0001). IFAT and ELISA highly concurred in their detection of specific S. stercoralis IgA and IgG antibodies in serum and in milk samples reconfirming prior studies that the serological method is a complement to the direct diagnosis of the parasite, and suggesting that immunological methods using milk samples can also be helpful. Furthermore, in endemic areas, infants may acquire antibodies to S. stercoralis from breast milk, possibly, contributing to the enhancement of specific mucosal immunity against this parasite.
Laassri, Majid; Mee, Edward T; Connaughton, Sarah M; Manukyan, Hasmik; Gruber, Marion; Rodriguez-Hernandez, Carmen; Minor, Philip D; Schepelmann, Silke; Chumakov, Konstantin; Wood, David J
2018-06-22
Bovine viral diarrhoea virus (BVDV) is a cattle pathogen that has previously been reported to be present in bovine raw materials used in the manufacture of biological products for human use. Seven lots of trivalent measles, mumps and rubella (MMR) vaccine and 1 lot of measles vaccine from the same manufacturer, together with 17 lots of foetal bovine serum (FBS) from different vendors, 4 lots of horse serum, 2 lots of bovine trypsin and 5 lots of porcine trypsin were analysed for BVDV using recently developed techniques, including PCR assays for BVDV detection, a qRT-PCR and immunofluorescence-based virus replication assays, and deep sequencing to identify and genotype BVDV genomes. All FBS lots and one lot of bovine-derived trypsin were PCR-positive for the presence of BVDV genome; in contrast all vaccine lots and the other samples were negative. qRT-PCR based virus replication assay and immunofluorescence-based infection assay detected no infectious BVDV in the PCR-positive samples. Complete BVDV genomes were generated from FBS samples by deep sequencing, and all were BVDV type 1. These data confirmed that BVDV nucleic acid may be present in bovine-derived raw materials, but no infectious virus or genomic RNA was detected in the final vaccine products. Copyright © 2018 International Alliance for Biological Standardization. All rights reserved.
Kang, Keren; Wu, Peidian; Li, Wenmei; Tang, Shixing; Wang, Jihua; Luo, Xiaochun; Xie, Mingquan
2015-01-01
To develop a rapid, sensitive and specific assay for quantification of serum heart-type fatty acid binding protein (H-FABP) based on immunofluorescence of specific monoclonal antibodies. We generated novel H-FABP-directed monoclonal antibodies by cloning of spleen cells of mice immunized with H-FABP. Epitopes were mapped and antigen affinity was assessed by surface plasmon resonance (SPR). The H-FABP specific monoclonal antibodies were coupled to fluorescent beads and sprayed onto a nitrocellulose membrane facilitating quantification of H-FABP by immunofluorescence. Reagent cross-reactivity, interference resistance, accuracy and sensitivity were examined. A total of 103 clinical samples were used to compare the sensitivity and specificity of the new assay to a commercially available Randox kit. This new assay could be finished within 15 min, with sensitivity reaching 1 ng/ml. In a trial of 103 clinical serum samples, the new testing kit results were highly correlated with those from the Randox kit (R(2) = 0.9707). Using the Randox kit as the reference kit, the sensitivity of the new assay was 98.25%, and specificity was 100%. An immunofluorescence-based H-FABP assay employing novel monoclonal antibodies could rapidly, specifically and sensitively detect H-FABP in serum samples, providing an effective method for rapid clinical assessment of H-FABP index in the clinic.
de Moraes, F M; Espósito, D L A; Klein, T M; da Fonseca, B A L
2018-01-01
Clinical manifestations of Zika, dengue, and chikungunya virus infections are very similar, making it difficult to reach a diagnosis based only on clinical grounds. In addition, there is an intense cross-reactivity between antibodies directed to Zika virus and other flaviviruses, and an accurate Zika diagnosis is best achieved by real-time RT-PCR. However, some real-time RT-PCR show better performance than others. To reach the best possible Zika diagnosis, the analytic sensitivity of some probe-based real-time RT-PCR amplifying Zika virus RNA was evaluated in spiked and clinical samples. We evaluated primers and probes to detect Zika virus, which had been published before, and tested sensitivity using serum spiked and patient samples by real-time RT-PCR. When tested against spiked samples, the previously described primers showed different sensitivity, with very similar results when samples from patients (serum and urine) were analyzed. Real-time RT-PCR designed to amplify Zika virus NS1 showed the best analytical sensitivity for all samples.
Javorska, Lenka; Krcmova, Lenka Kujovska; Solich, Petr; Kaska, Milan
2017-08-05
Management of the therapy of life-threatening bacterial infection is extremely based on an optimal antibiotic treatment. Achieving the correct vancomycin dosage in blood and target tissues can be complicated in special situations, e.g., where large fluid sequestration and/or acute renal failure occur. A UHPLC-MS/MS method operating in electrospray (ESI) positive ion mode was applied for the determination of vancomycin in serum, urine and peritoneal/pleural effusion. Sample pretreatment was composed of dilution and simple protein precipitation where only a small volume (50μL) of serum, urine or peritoneal/pleural effusion was required. The separation of vancomycin was performed on a Meteoric Core C18 BIO column (100×4.6mm, 2.7μm) by gradient elution with 0.1% formic acid in water and acetonitrile. The total time of analysis was 4.5min. The method was found to be linear in the range of 2-60μM (or 0.5-10μM) for serum, 0.27-10μM (or 2-60μM) for peritoneal/pleural effusion and 25-300μM for urine, which was adequate for the determination of vancomycin in patient samples. The intra- and inter-day precision was below 8% RSD, and accuracy was from 89 to 104%. The UHPLC/MS-MS method offers a fast and reliable approach to determine vancomycin concentrations in three different human body fluid samples (serum, urine and peritoneal/pleural effusion) with a simple sample pretreatment that was the same for all selected specimens. This method should be applicable to large sample series in clinical (pharmacokinetic/pharmacodynamic) studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhou, Tong; Yang, Rupu; Li, Shihong; Zheng, Guoqing; Xi, Yu; Cheng, Xuemin; Hou, Jiaxiang; Cui, Liuxin; Ba, Yue
2013-03-01
To explore the influence of water fluoride exposure on sex hormone binding globulin (SHBG) and testosterone in adult male. Cross-sectional study was conducted in three villages of Tongxu county including high fluoride group (HFG), defluoridation project group (DFPG) and control group (CG) based on the fluoride concentration in drinking water. Adult male who were born and raised in the village and aged 18 - 50 years old were recruited using cluster sampling. Fasting blood and morning urine samples were collected. The fluoride levels in drinking water and urine were detected by fluoride-ion selective electrode method. Serum SHBG level was determined using enzyme-linked immunosorbent assay (ELISA). The chemical luminescence immune analysis method was used to detect serum testosterone content. Serum SHBG level was 47.85 nmol/L in CG, 31.37 nmol/L in DFPG and 24.52 nmol/L in HFG respectively. There were significant difference among of three groups (P < 0.05). Serum testosterone level was 3.69 ng/ml in CG, 4.61 ng/ml in DFPG and 4.83 ng/ml in HFG respectively. Serum testosterone level in HFG was significantly higher than that in CG (P < 0.05). Serum SHBG level in HFG has positive correlation with serum testosterone (r = 0.230, P = 0.049), which has not been observed in DFPG and CG. Long-time fluorine exposure may affect serum SHBG and testosterone level in adult male.
Nucleic Acid-Based Cross-Linking Assay for Detection and Quantification of Hepatitis B Virus DNA
Lai, Vicky C. H.; Guan, Richard; Wood, Michael L.; Lo, Su Kong; Yuen, Man-Fung; Lai, Ching-Lung
1999-01-01
A nucleic acid photo-cross-linking technology was used to develop a direct assay for the quantification of hepatitis B virus (HBV) DNA levels in serum. Cross-linker-modified DNA probes complementary to the viral genomes of the major HBV subtypes were synthesized and used in an assay that could be completed in less than 6 h. The quantification range of the assay, as determined by testing serial dilutions of Eurohep HBV reference standards and cloned HBV DNA, was 5 × 105 to 3 × 109 molecules of HBV DNA/ml of serum. Within-run and between-run coefficients of variation (CVs) for the assay were 4.3 and 4.0%, respectively. The assay was used to determine HBV DNA levels in 302 serum samples, and the results were compared to those obtained after testing the same samples with the Chiron branched-DNA (bDNA) assay for HBV DNA. Of the samples tested, 218 were positive for HBV DNA by both assays and 72 gave results below the cutoff for both assays. Of the remaining 12 samples, 10 were positive for HBV DNA by the cross-linking assay only; the 2 other samples were positive by the bDNA assay only. Twenty-eight samples had to be retested by the bDNA assay (CV, >20% between the results obtained from the testing of each sample in duplicate), whereas only three samples required retesting by the cross-linking assay. The correlation between the HBV DNA levels, as measured by the two tests, was very high (r = 0.902; P = 0.01). We conclude that the cross-linking assay is a sensitive and reproducible method for the detection and quantification of HBV DNA levels in serum. PMID:9854083
Küme, Tuncay; Sağlam, Barıs; Ergon, Cem; Sisman, Ali Rıza
2018-01-01
The aim of this study is to evaluate and compare the analytical performance characteristics of the two creatinine methods based on the Jaffe and enzymatic methods. Two original creatinine methods, Jaffe and enzymatic, were evaluated on Architect c16000 automated analyzer via limit of detection (LOD) and limit of quantitation (LOQ), linearity, intra-assay and inter-assay precision, and comparability in serum and urine samples. The method comparison and bias estimation using patient samples according to CLSI guideline were performed on 230 serum and 141 urine samples by analyzing on the same auto-analyzer. The LODs were determined as 0.1 mg/dL for both serum methods and as 0.25 and 0.07 mg/dL for the Jaffe and the enzymatic urine method respectively. The LOQs were similar with 0.05 mg/dL value for both serum methods, and enzymatic urine method had a lower LOQ than Jaffe urine method, values at 0.5 and 2 mg/dL respectively. Both methods were linear up to 65 mg/dL for serum and 260 mg/dL for urine. The intra-assay and inter-assay precision data were under desirable levels in both methods. The higher correlations were determined between two methods in serum and urine (r=.9994, r=.9998 respectively). On the other hand, Jaffe method gave the higher creatinine results than enzymatic method, especially at the low concentrations in both serum and urine. Both Jaffe and enzymatic methods were found to meet the analytical performance requirements in routine use. However, enzymatic method was found to have better performance in low creatinine levels. © 2017 Wiley Periodicals, Inc.
Supercritical fluid extraction of selected pharmaceuticals from water and serum.
Simmons, B R; Stewart, J T
1997-01-24
Selected drugs from benzodiazepine, anabolic agent and non-steroidal anti-inflammatory drug (NSAID) therapeutic classes were extracted from water and serum using a supercritical CO2 mobile phase. The samples were extracted at a pump pressure of 329 MPa, an extraction chamber temperature of 45 degrees C, and a restrictor temperature of 60 degrees C. The static extraction time for all samples was 2.5 min and the dynamic extraction time ranged from 5 to 20 min. The analytes were collected in appropriate solvent traps and assayed by modified literature HPLC procedures. Analyte recoveries were calculated based on peak height measurements of extracted vs. unextracted analyte. The recovery of the benzodiazepines ranged from 80 to 98% in water and from 75 to 94% in serum. Anabolic drug recoveries from water and serum ranged from 67 to 100% and 70 to 100%, respectively. The NSAIDs were recovered from water in the 76 to 97% range and in the 76 to 100% range from serum. Accuracy, precision and endogenous peak interference, if any, were determined for blank and spiked serum extractions and compared with classical sample preparation techniques of liquid-liquid and solid-phase extraction reported in the literature. For the benzodiazepines, accuracy and precision for supercritical fluid extraction (SFE) ranged from 1.95 to 3.31 and 0.57 to 1.25%, respectively (n = 3). The SFE accuracy and precision data for the anabolic agents ranged from 4.03 to 7.84 and 0.66 to 2.78%, respectively (n = 3). The accuracy and precision data reported for the SFE of the NSAIDs ranged from 2.79 to 3.79 and 0.33 to 1.27%, respectively (n = 3). The precision of the SFE method from serum was shown to be comparable to the precision obtained with other classical preparation techniques.
Metabolic Footprinting of Fermented Milk Consumption in Serum of Healthy Men
Pimentel, Grégory; Burton, Kathryn J; von Ah, Ueli; Bütikofer, Ueli; Pralong, François P; Vionnet, Nathalie; Portmann, Reto; Vergères, Guy
2018-01-01
Abstract Background Fermentation is a widely used method of natural food preservation that has consequences on the nutritional value of the transformed food. Fermented dairy products are increasingly investigated in view of their ability to exert health benefits beyond their nutritional qualities. Objective To explore the mechanisms underpinning the health benefits of fermented dairy intake, the present study followed the effects of milk fermentation, from changes in the product metabolome to consequences on the human serum metabolome after its ingestion. Methods A randomized crossover study design was conducted in 14 healthy men [mean age: 24.6 y; mean body mass index (in kg/m2): 21.8]. At the beginning of each test phase, serum samples were taken 6 h postprandially after the ingestion of 800 g of a nonfermented milk or a probiotic yogurt. During the 2-wk test phases, subjects consumed 400 g of the assigned test product daily (200 g, 2 times/d). Serum samples were taken from fasting participants at the end of each test phase. The serum metabolome was assessed through the use of LC-MS–based untargeted metabolomics. Results Postprandial serum metabolomes after milk or yogurt intake could be differentiated [orthogonal projections to latent structures discriminant analysis (OPLS-DA) Q2 = 0.74]. Yogurt intake was characterized by higher concentrations of 7 free amino acids (including proline, P = 0.03), reduced concentrations of 5 bile acids (including glycocholic acid, P = 0.04), and modulation of 4 indole derivative compounds (including indole lactic acid, P = 0.01). Fasting serum samples after 2 wk of daily intake of milk or yogurt could also be differentiated based on their metabolic profiles (OPLS-DA Q2 = 0.56) and were discussed in light of the postprandial results. Conclusion Metabolic pathways related to amino acids, indole derivatives, and bile acids were modulated in healthy men by the intake of yogurt. Further investigation to explore novel health effects of fermented dairy products is warranted.This trial was registered at clinicaltrials.gov as NCT02230345. PMID:29788433
Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem
2016-04-01
A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.
Wollanke, B; Gerhards, H; Brem, S; Kopp, H; Meyer, P
1998-04-01
Between February 1993 and July 1997, 150 horses suffering from recurrent uveitis were subjected to parsplana vitrectomy. In these horses, antibody titers to Leptospira serovars were determined in serum samples and in samples from diluted vitreous collected during vitrectomy. Although the vitreous samples were diluted with 250 ml of balanced salt solution, in 86 of the 150 vitreous samples (= 57%) the antibody titers were higher than in the serum samples. Additionally, serum samples from 77 horses suffering from ERU, but which were not subjected to vitrectomy, and serum samples from 97 horses with clinically normal eyes were analyzed for antibodies to Leptospira serovars. Among the 227 horses with ERU (150 treated surgically, 77 treated conservatively) 50 horses (50 of 227 = 22%) had serum antibody titers to Leptospira serovars of > or = 1:800. Among the 97 horses with clinically normal eyes, 24 horses (24 of 97 = 25%) had serum antibody titers to Leptospira serovars of > or = 1:800. In undiluted vitreous samples from 20 horses with clinically normal eyes, no antibody titers to Leptospira serovars could be detected. Among the 150 horses with ERU, 90 animals (90 of 150 = 60%) had antibody titers of > or = 1:100 in the diluted vitreous samples, the difference being highly significant (p < 0.001). The findings are discussed in relation to the etiology of recurrent uveitis in horses.
NASA Astrophysics Data System (ADS)
Tran, Quang Huy; Hanh Nguyen, Thi Hong; Mai, Anh Tuan; Thuy Nguyen, Thi; Khue Vu, Quang; Nga Phan, Thi
2012-03-01
This paper describes the development of electrochemical immunosensors based on human serum antibodies with different immobilization methods for detection of Japanese encephalitis virus (JEV). Human serum containing anti-JEV antibodies was used to immobilize onto the surface of silanized interdigitated electrodes by four methods: direct adsorption (APTES-serum), covalent binding with a cross linker of glutaraldehyde (APTES-GA-serum), covalent binding with a cross linker of glutaraldehyde combined with anti-human IgG (APTES-GA-anti-HIgG-serum) and covalent binding with a cross linker of glutaraldehyde combined with a bioaffinity of protein A (APTES-GA-PrA-serum). Atomic force microscopy was used to verify surface characteristics of the interdigitated electrodes before and after treatment with serum antibodies. The output signal of the immunosensors was measured by the change of conductivity resulting from the specific binding of JEV antigens and serum antibodies immobilized on the electrodes, with the help of horseradish peroxidase (HRP)-labeled secondary antibody against JEV. The results showed that the APTES-GA-PrA-serum method provided the highest signal of the electrochemical immunosensor for detection of JEV antigens, with the linear range from 25 ng ml-1 to 1 μg ml-1, and the limit of detection was about 10 ng ml-1. This study shows a potential development of novel electrochemical immunosensors applied for virus detection in clinical samples in case of possible outbreaks.
Franklin, Ashley D; Crosier, Adrienne E; Vansandt, Lindsey M; Mattson, Elliot; Xiao, Zhengguo
2015-06-01
Peripheral blood mononuclear cells (PBMCs) were isolated from the whole blood of cheetahs (Acinonyx jubatus ; n=3) and stimulated with lipopolysaccharides (LPS) to induce the production of proinflammatory cytokines TNF-α, IL-1β, and IL-6 for establishment of cross-reactivity between these cheetah cytokines and feline-specific cytokine antibodies provided in commercially available Feline DuoSet® ELISA kits (R&D Systems, Inc., Minneapolis, Minnesota 55413, USA). This study found that feline-specific cytokine antibodies bind specifically to cheetah proinflammatory cytokines TNF-α, IL-1β, and IL-6 from cell culture supernatants. The assays also revealed that cheetah PBMCs produce a measurable, cell concentration-dependent increase in proinflammatory cytokine production after LPS stimulation. To enable the use of these kits, which are designed for cell culture supernatants for analyzing cytokine concentrations in cheetah serum, percent recovery and parallelism of feline cytokine standards in cheetah serum were also evaluated. Cytokine concentrations in cheetah serum were approximated based on the use of domestic cat standards in the absence of cheetah standard material. In all cases (for cytokines TNF-α, IL-1β, and IL-6), percent recovery increased as the serum sample dilution increased, though percent recovery varied between cytokines at a given dilution factor. A 1:2 dilution of serum resulted in approximately 45, 82, and 7% recovery of TNF-α, IL-1β, and IL-6 standards, respectively. Adequate parallelism was observed across a large range of cytokine concentrations for TNF-α and IL-1β; however, a significant departure from parallelism was observed between the IL-6 standard and the serum samples (P=0.004). Therefore, based on our results, the Feline DuoSet ELISA (R&D Systems, Inc.) kits are valid assays for the measurement of TNF-α and IL-1β in cheetah serum but should not be used for accurate measurement of IL-6.
Chen, Rui; Tan, Yexiong; Wang, Min; Wang, Fangjun; Yao, Zhenzhen; Dong, Liwei; Ye, Mingliang; Wang, Hongyang; Zou, Hanfa
2011-01-01
A robust, reproducible, and high throughput method was developed for the relative quantitative analysis of glycoprotein abundances in human serum. Instead of quantifying glycoproteins by glycopeptides in conventional quantitative glycoproteomics, glycoproteins were quantified by nonglycosylated peptides derived from the glycoprotein digest, which consists of the capture of glycoproteins in serum samples and the release of nonglycopeptides by trypsin digestion of captured glycoproteins followed by two-dimensional liquid chromatography-tandem MS analysis of released peptides. Protein quantification was achieved by comparing the spectrum counts of identified nonglycosylated peptides of glycoproteins between different samples. This method was demonstrated to have almost the same specificity and sensitivity in glycoproteins quantification as capture at glycopeptides level. The differential abundance of proteins present at as low as nanogram per milliliter levels was quantified with high confidence. The established method was applied to the analysis of human serum samples from healthy people and patients with hepatocellular carcinoma (HCC) to screen differential glycoproteins in HCC. Thirty eight glycoproteins were found with substantial concentration changes between normal and HCC serum samples, including α-fetoprotein, the only clinically used marker for HCC diagnosis. The abundance changes of three glycoproteins, i.e. galectin-3 binding protein, insulin-like growth factor binding protein 3, and thrombospondin 1, which were associated with the development of HCC, were further confirmed by enzyme-linked immunosorbent assay. In conclusion, the developed method was an effective approach to quantitatively analyze glycoproteins in human serum and could be further applied in the biomarker discovery for HCC and other cancers. PMID:21474793
Reference measurement procedure for total glycerides by isotope dilution GC-MS.
Edwards, Selvin H; Stribling, Shelton L; Pyatt, Susan D; Kimberly, Mary M
2012-04-01
The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum. We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [(13)C(3)]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b). The calibration response was linear for the range of calibrator concentrations examined (0-1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123-0.7225) and 0.3122 (95% CI, 0.3096-0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%. This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.
Lanshoeft, Christian; Wolf, Thierry; Walles, Markus; Barteau, Samuel; Picard, Franck; Kretz, Olivier; Cianférani, Sarah; Heudi, Olivier
2016-11-30
An increasing demand of new analytical methods is associated with the growing number of biotherapeutic programs being prosecuted in the pharmaceutical industry. Whilst immunoassay has been the standard method for decades, a great interest in assays based on liquid chromatography tandem mass spectrometry (LC-MS/MS) is evolving. In this present work, the development of a generic method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G (hIgG) in rat serum is reported. The method is based on four generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), VVSVLTVLHQDWLNGK (VVS) and FNWYVDGVEVHNAK (FNW) originating from different parts of the fraction crystallizable (Fc) region of a reference hIgG1 (hIgG1A). A tryptic pellet digestion of rat serum spiked with hIgG1A and a stable isotope labeled protein (hIgG1B) used as internal standard (ISTD) was applied prior LC-MS/MS analysis. The upper limit of quantification was at 1000μg/mL. The lower limit of quantitation was for GPS, TTP and VVS at 1.00μg/mL whereas for FNW at 5.00μg/mL. Accuracy and precision data met acceptance over three days. The presented method was further successfully applied to the quantitative analysis of other hIgG1s (hIgG1C and hIgG1D) and hIgG4-based therapeutic proteins on spiked quality control (QC) samples in monkey and rat serum using calibration standards (Cs) prepared with hIgG1A in rat serum. In order to extend the applicability of our generic approach, a bispecific-bivalent hIgG1 (bb-hIgG1) and two lysine conjugated antibody-drug conjugates (ADC1 and ADC2) were incorporated as well. The observed values on spiked QC samples in monkey serum were satisfactory with GPS for the determination of bb-hIgG1 whereas the FNW and TTP peptides were suitable for the ADCs. Moreover, comparable mean concentration-time profiles were obtained from monkeys previously dosed intravenously with ADC2 measured against Cs samples prepared either with hIgG1A in rat serum (presented approach) or with the actual ADC2 in monkey serum (conventional approach). The results of this study highlight the great flexibility of our newly developed generic approach and that the choice of the surrogate peptide still remains critical when dealing with different matrix types or modalities. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Chun Wei; Manne, Upender; Reddy, Vishnu B.; Oelschlager, Denise K.; Katkoori, Venkat R.; Grizzle, William E.; Kapoor, Rakesh
2010-11-01
A combination tapered fiber-optic biosensor (CTFOB) dip probe for rapid and cost-effective quantification of proteins in serum samples has been developed. This device relies on diode laser excitation and a charged-coupled device spectrometer and functions on a technique of sandwich immunoassay. As a proof of principle, this technique was applied in a quantitative estimation of interleukin IL-6. The probes detected IL-6 at picomolar levels in serum samples obtained from a patient with lupus, an autoimmune disease, and a patient with lymphoma. The estimated concentration of IL-6 in the lupus sample was 5.9 +/- 0.6 pM, and in the lymphoma sample, it was below the detection limit. These concentrations were verified by a procedure involving bead-based xMAP technology. A similar trend in the concentrations was observed. The specificity of the CTFOB dip probes was assessed by analysis with receiver operating characteristics. This analysis suggests that the dip probes can detect 5-pM or higher concentration of IL-6 in these samples with specificities of 100%. The results provide information for guiding further studies in the utilization of these probes to quantify other analytes in body fluids with high specificity and sensitivity.
Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J. G.; Morton, C. Oliver; Barnes, Rosemary A.; Donnelly, J. Peter; White, P. Lewis
2015-01-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. PMID:26085614
Serum levels of inhibin A and inhibin B in women with normal and abnormal luteal function.
Yamoto, M; Imai, M; Otani, H; Nakano, R
1997-05-01
To determine whether serum inhibin A and inhibin B concentrations are lower in patients with luteal dysfunction than in women with normal luteal function. Serum samples were collected from seven healthy women with regular menstrual cycles. Serum samples on days +5 to +9 after the LH surge were collected from patients with luteal dysfunction. The diagnosis of luteal dysfunction was based on a luteal phase duration less than 11 days and a single midluteal progesterone level below 10 ng/mL. Serum levels of inhibin A, inhibin B, progesterone, estradiol (E2), FSH, and LH were measured. The serum inhibin A levels were increased toward the late follicular phase. The levels reached a maximum during the midluteal phase, followed by a fall during the late luteal phase. The serum inhibin B levels were high during the follicular phases and the early luteal phase. The levels decreased during the midluteal and late luteal phases. Serum levels (mean +/- standard error of the mean) of inhibin A in patients with luteal dysfunction were significantly lower than those in women during the midluteal phase (26.2 +/- 2.9 compared to 41.9 +/- 2.8 pg/mL; P < .01) in addition to the expected decrease in serum progesterone levels (6.3 +/- 0.7 compared to 14.7 +/- 1.2 ng/mL; P < .01). Serum inhibin B levels did not differ significantly between normal women and those with luteal dysfunction. There also were no significant differences in the E2, FSH, and LH levels. Levels of inhibin A, but not of inhibin B, may reflect the human luteal function.
Loeffler, Juergen; Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J G; Morton, C Oliver; Barnes, Rosemary A; Donnelly, J Peter; White, P Lewis
2015-09-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. Copyright © 2015 Loeffler et al.
O'Bryant, Sid E; Xiao, Guanghua; Barber, Robert; Huebinger, Ryan; Wilhelmsen, Kirk; Edwards, Melissa; Graff-Radford, Neill; Doody, Rachelle; Diaz-Arrastia, Ramon
2011-01-01
There is no rapid and cost effective tool that can be implemented as a front-line screening tool for Alzheimer's disease (AD) at the population level. To generate and cross-validate a blood-based screener for AD that yields acceptable accuracy across both serum and plasma. Analysis of serum biomarker proteins were conducted on 197 Alzheimer's disease (AD) participants and 199 control participants from the Texas Alzheimer's Research Consortium (TARC) with further analysis conducted on plasma proteins from 112 AD and 52 control participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI). The full algorithm was derived from a biomarker risk score, clinical lab (glucose, triglycerides, total cholesterol, homocysteine), and demographic (age, gender, education, APOE*E4 status) data. Alzheimer's disease. 11 proteins met our criteria and were utilized for the biomarker risk score. The random forest (RF) biomarker risk score from the TARC serum samples (training set) yielded adequate accuracy in the ADNI plasma sample (training set) (AUC = 0.70, sensitivity (SN) = 0.54 and specificity (SP) = 0.78), which was below that obtained from ADNI cerebral spinal fluid (CSF) analyses (t-tau/Aβ ratio AUC = 0.92). However, the full algorithm yielded excellent accuracy (AUC = 0.88, SN = 0.75, and SP = 0.91). The likelihood ratio of having AD based on a positive test finding (LR+) = 7.03 (SE = 1.17; 95% CI = 4.49-14.47), the likelihood ratio of not having AD based on the algorithm (LR-) = 3.55 (SE = 1.15; 2.22-5.71), and the odds ratio of AD were calculated in the ADNI cohort (OR) = 28.70 (1.55; 95% CI = 11.86-69.47). It is possible to create a blood-based screening algorithm that works across both serum and plasma that provides a comparable screening accuracy to that obtained from CSF analyses.
1980-11-01
hours, then overnight in a refrigerator or cold room at 40C. Fol- lowing clot retraction , the serum may be decanted and spun, or the whole sample spun...Drogram. The SIMP programme may involve one or all of the following: collection of post nasal swabs, blood sera samples, air samples and surface samples...outlined in para 16. 16. Culturing of Swabs Swabs shall be placed on Columbia Blood Agar (4 or 5% sheep RBC’s) supplemented with IsoVitalex (Baltimore
Serum TIMP1 and TIMP2 concentration in patients with different grades of meningioma.
Mashayekhi, Farhad; Saberi, Alia; Mashayekhi, Sohail
2018-07-01
Meningiomas are common primary brain tumors that constitute about 13% of all intracranial tumors. Matrix metalloproteinase-9 (MMP-9) is able to degrade the extracellular matrix and basement membrane leading to cancer cell invasion and metastasis. MMPs are specifically inhibited by a family of small extracellular proteins known as the tissue inhibitors of metalloproteinases (TIMPs). The objective of this project was to evaluate serum concentration of TIMP-1 and TIMP-2 in patients with different grades of meningioma. Ninety samples from different stages of patients with meningitis (42 cases of grade I, 28 grade II, 20 grade III) and 51 samples from normal healthy were included in this study. Total protein concentration (TPC) and the level TIMP-1 and TIMP-2 serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay (ELISA), respectively. No significant change in the TPC was seen in the serum of patients with meningioma when compared with normal controls. Results obtained demonstrated that all serum samples presented TIMP-1 and TIMP-2 expression, whereas, starting from grade I to III meningiomas, a significant decrease of TIMP-1 and TIMP-2 expression was observed as compared to controls. The results of this study show that a low expression of TIMP1 and TIMP2 is correlated with advanced stages of meningioma. It is also concluded that the detection of serum TIMP1 and TIMP2 may be useful in classifying different grades of meningioma. Copyright © 2018 Elsevier B.V. All rights reserved.
Baillargeon, Paul; Arango-Sabogal, Juan C; Wellemans, Vincent; Fecteau, Gilles
2017-04-01
The objective of this study was to determine if precolostral blood samples are useful to detect apparent fetal infections with bovine viral diarrhea (BVD) and infectious bovine rhinotracheitis (IBR) viruses. A convenience sample of 317 sera from 50 Canadian herds was used in the study. Antibody level was measured using 2 commercial IBR and BVD ELISA kits. Precolostral status of sera was confirmed on 304 samples using serum gamma-glutamyl transferase activity. Postcolostral serum samples yielded a higher proportion of positive results to IBR (OR = 86; 95% CI: 17.8 to 415.7) and BVD (OR = 199.3; 95% CI: 41.7 to 952.3) than did precolostral samples. All positive precolostral serum samples ( n = 7 of 304) originated from calves born to vaccinated cows. Postcolostral positive serum samples ( n = 11 of 13) originated mostly (60%) from calves born to non-vaccinated cows. Precolostral serum sampling can detect apparent fetal infections in a herd.
Ramos, Inês I; Magalhães, Luís M; Barreiros, Luisa; Reis, Salette; Lima, José L F C; Segundo, Marcela A
2018-01-01
Immunoglobulin G (IgG) represents the major fraction of antibodies in healthy adult human serum, and deviations from physiological levels are a generic marker of disease corresponding to different pathologies. Therefore, screening methods for IgG evaluation are a valuable aid to diagnostics. The present work proposes a rapid, automatic, and miniaturized method based on UV-vis micro-bead injection spectroscopy (μ-BIS) for the real-time determination of human serum IgG with label-free detection. Relying on attachment of IgG in rec-protein G immobilized in Sepharose 4B, a bioaffinity column is automatically assembled, where IgG is selectively retained and determined by on-column optical density measurement. A "dilution-and-shoot" approach (50 to 200 times) was implemented without further sample treatment because interferences were flushed out of the column upon sample loading, with minimization of carryover and cross-contamination by automatically discarding the sorbent (0.2 mg) after each determination. No interference from human serum albumin at 60 mg mL -1 in undiluted sample was found. The method allowed IgG determination in the range 100-300 μg mL -1 (corresponding to 5.0-60 mg mL -1 in undiluted samples), with a detection limit of 33 μg mL -1 (1.7 mg mL -1 for samples, dilution factor of 50). RSD values were < 9.4 and < 11.7%, for intra and inter-assay precision, respectively, while recovery values for human serum spiked with IgG at high pathological levels were 97.8-101.4%. Comparison to commercial ELISA kit showed no significant difference for tested samples (n = 8). Moreover, time-to-result decreased from several hours to < 5 min and analysis cost decreased 10 times, showing the potential of the proposed approach as a point-of-care method. Graphical abstract Micro-Bead Injection Spectroscopy method for real time, automated and label-free determination of total serum human Immunoglobulin G (IgG). The method was designed for Lab-on-Valve (LOV) platforms using a miniaturised protein G bioaffinity separative approach. IgG are separated from serum matrix components upon quantification with low non-specific binding in less than 5 min.
Wei, Fang; Cheng, Scott; Korin, Yael; Reed, Elaine F; Gjertson, David; Ho, Chih-ming; Gritsch, H Albin; Veale, Jeffrey
2012-09-18
Kidney transplant recipients who have abnormally high creatinine levels in their blood often have allograft dysfunction secondary to rejection. Creatinine has become the preferred marker for renal dysfunction and is readily available in hospital clinical settings. We developed a rapid and accurate polymer-based electrochemical point-of-care (POC) assay for creatinine detection from whole blood to identify allograft dysfunction. The creatinine concentrations of 19 blood samples from transplant recipients were measured directly from clinical serum samples by the conducting polymer-based electrochemical (EC) sensor arrays. These measurements were compared to the traditional clinical laboratory assay. The time required for detection was <5 min from sample loading. Sensitivity of the detection was found to be 0.46 mg/dL of creatinine with only 40 μL sample in the creatinine concentration range of 0 mg/dL to 11.33 mg/dL. Signal levels that were detected electrochemically correlated closely with the creatinine blood concentration detected by the UCLA Ronald Reagan Medical Center traditional clinical laboratory assay (correlation coefficient = 0.94). This work is encouraging for the development of a rapid and accurate POC device for measuring creatinine levels in whole blood.
Evaluation of a Novel Isotope Biomarker for Dietary Consumption of Sweets
Yeung, Edwina H.; Saudek, Christopher D.; Jahren, A. Hope; Kao, Wen Hong Linda; Islas, Melissa; Kraft, Rebecca; Coresh, Josef; Anderson, Cheryl A. M.
2010-01-01
Carbon isotopic signatures (“δ13C”) might reflect consumption of corn- and cane-based sweeteners. The authors hypothesized that the δ13C value of human serum is higher for individuals with high versus low intakes of corn- and cane-based sweeteners (measured as sweetened beverage intake). They conducted a cross-sectional study within the Atherosclerosis Risk in Communities Magnetic Resonance Imaging study (Maryland, 2005–2006). Diet was assessed by food frequency questionnaire, and blinded serum samples were assayed by natural abundance stable isotope mass spectroscopy. Studied were 186 participants (53% male; mean age, 71 years; mean body mass index, 30 kg/m2). Serum δ13C values for individuals with high sweetened beverage intakes were significantly higher than for those with low intakes (−19.15‰ vs. −19.47‰, P < 0.001). Serum δ13C value increased 0.20‰ for every serving/day of sweetened beverages (P < 0.01). The association between sweetened beverages and serum δ13C value remained significant after adjustment for confounding by corn-based product intake (P < 0.001). Serum δ13C values were also associated with waist circumference, body mass index, and waist-to-hip ratio. This study provides the first known evidence that the δ13C value of human serum differs between persons consuming low and high amounts of sweets. Within the proper framework, serum δ13C value could be developed into an objective biomarker promoting more reliable assessment of dietary sweets intake. PMID:20817784
Evaluation of a novel isotope biomarker for dietary consumption of sweets.
Yeung, Edwina H; Saudek, Christopher D; Jahren, A Hope; Kao, Wen Hong Linda; Islas, Melissa; Kraft, Rebecca; Coresh, Josef; Anderson, Cheryl A M
2010-11-01
Carbon isotopic signatures ("δ¹³C") might reflect consumption of corn- and cane-based sweeteners. The authors hypothesized that the δ¹³C value of human serum is higher for individuals with high versus low intakes of corn- and cane-based sweeteners (measured as sweetened beverage intake). They conducted a cross-sectional study within the Atherosclerosis Risk in Communities Magnetic Resonance Imaging study (Maryland, 2005-2006). Diet was assessed by food frequency questionnaire, and blinded serum samples were assayed by natural abundance stable isotope mass spectroscopy. Studied were 186 participants (53% male; mean age, 71 years; mean body mass index, 30 kg/m²). Serum δ¹³C values for individuals with high sweetened beverage intakes were significantly higher than for those with low intakes (-19.15‰ vs. -19.47‰, P < 0.001). Serum δ¹³C value increased 0.20‰ for every serving/day of sweetened beverages (P < 0.01). The association between sweetened beverages and serum δ¹³C value remained significant after adjustment for confounding by corn-based product intake (P < 0.001). Serum δ¹³C values were also associated with waist circumference, body mass index, and waist-to-hip ratio. This study provides the first known evidence that the δ¹³C value of human serum differs between persons consuming low and high amounts of sweets. Within the proper framework, serum δ¹³C value could be developed into an objective biomarker promoting more reliable assessment of dietary sweets intake.
Drug residues in serum of dogs receiving anticancer chemotherapy.
Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D
2010-01-01
The presence of drug residues in blood samples can represent an occupational hazard. However, studies on cytotoxic drug residues in serum of dogs are lacking in veterinary oncology. To evaluate possible occupational hazards associated with handling of blood samples from dogs receiving oncolytic drugs 7 days after treatment. Twenty-seven client-owned dogs treated for lymphoma or mast cell tumors with vincristine, vinblastine, cyclophosphamide, or doxorubicin. Prospective, observational study. Serum samples were either taken 7 days after administration of vincristine, cyclophosphamide, doxorubicin (lymphoma), and vinblastine (mast cell tumor), or 1-2 days after the last concurrent oral administration of cyclophosphamide (mast cell tumor). Additionally, serum was collected within 5 minutes of treatment. Measurement of drug residues in serum was performed by liquid chromatography tandem mass spectrometry (LC/MS/MS). In 33 samples collected within 5 minute of treatment, the median serum concentrations were vincristine: 37 microg/L (range: 11-87 microg/L), vinblastine: 13 microg/L (range: 13-35 microg/L), cyclophosphamide: 2,484 microg/L (range: 1,209-2,778 microg/L), doxorubicin: 404 microg/L (range: 234-528 microg/L). In 81 serum samples collected 7 days after treatment vinblastine (7 microg/L) was detected in 1 sample, and cyclophosphamide (7 and 9 microg/L) in 2 samples collected 1-2 days after oral administration of cyclophosphamide. Medications were not detected in any of the other samples. Handling of blood samples from dogs receiving oncolytic chemotherapy 7 days after treatment with vincristine, vinblastine, cyclophosphamide, and doxorubicin should not present a health hazard.
Yılmaz, Cansu; Köksal, Nilgün; Özkan, Hilal; Dorum, Bayram Ali; Bağcı, Onur
2017-01-01
Yılmaz C, Köksal N, Özkan H, Dorum BA, Bağcı O. Low serum IGF-1 and increased cytokine levels in tracheal aspirate samples are associated with bronchopulmonary dysplasia. Turk J Pediatr 2017; 59: 122-129. Despite developments in the perinatal and neonatal care, bronchopulmonary dysplasia (BPD) is still the most frequently seen long-term complication in preterm infants. The aim of this prospective study is to investigate the association between the development of BPD and serial measurements of IGF-1 levels and their relationship with levels of IGF-1 and cytokine in tracheal aspirate fluids. A total of 40 premature infants, born at a gestational age of ≤ 32 weeks, were enrolled in the study. On postnatal day-1, 3, 7, 21 and 28 serum IGF-1 levels and IGF-1 levels, IL-6, IL-8, IL-10 and TNF-alpha levels in tracheal aspirate fluid samples of intubated cases were examined. Mean gestational age of 40 patients included in the study was 29.41 ± 2.23 weeks, and their mean birth weight was 1,256.85 ± 311.48 g. BPD was detected in 35% of cases. Mean gestational week and birth weight of the cases that developed BPD were 30 ± 3 weeks and 1,150 ± 295 g, respectively. Serum IGF-1 levels on postnatal day-1, 3, 7, 21 and 28 in cases who developed BPD were significantly lower when compared with those without BPD (p < 0.01). Levels of IL-6, IL-8, IL-10, and TNF-alpha in tracheal aspirate samples were significantly higher in cases with BPD compared to those without BPD (p < 0.05). IGF-1 levels in tracheal aspirate fluid samples did not differ significantly based on the presence of BPD (p > 0.05). Severity of BPD was associated with decreased serum IGF-1 levels and increased cytokine levels in tracheal aspirate samples.
Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina
2016-01-01
Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM, Artacho-Cordón F, Barriuso-Lapresa L, Tusquets I, Dierssen-Sotos T, Aragonés N, Olea N, Kogevinas M, Pollán M. 2016. Total effective xenoestrogen burden in serum samples and risk for breast cancer in a population-based multicase–control study in Spain. Environ Health Perspect 124:1575–1582; http://dx.doi.org/10.1289/EHP157 PMID:27203080
Walsh, Robert B.; Kelton, David F.; Hietala, Sharon K.; Duffield, Todd F.
2013-01-01
Serum and milk samples from 1229 cows on 22 Ontario dairy farms were individually tested for antibodies specific for bovine leukosis virus (BLV) and Neospora caninum by enzyme-linked immunosorbent assay (ELISA). Antibodies against BLV were present in 361 serum samples (29.4%) and 369 milk samples (30.0%). Comparing the 2 tests, agreement was almost perfect (k = 0.86; 95% CI = 0.83 to 0.90) and the proportions of samples positive were not significantly different (P = 0.56). Both tests identified the same 3 herds free of bovine leukosis virus. Antibodies against N. caninum were detected in 138 serum samples (11.2%), and 111 milk samples (9.0%). Agreement between the 2 tests was moderate (k = 0.52; 95% CI = 0.43 to 0.59). Four herds were free of neosporosis by the serum test, while 10 herds were negative by the milk test. The ELISA on milk samples facilitates sample collection to classify herds free of BLV; the milk N. caninum ELISA was less reliable in predicting herd-level infection. PMID:24082160
Gizaw, Solomon T; Ohashi, Tetsu; Tanaka, Masakazu; Hinou, Hiroshi; Nishimura, Shin-Ichiro
2016-08-01
Understanding of the significance of posttranslational glycosylation in Alzheimer's disease (AD) is of growing importance for the investigation of the pathogenesis of AD as well as discovery research of the disease-specific serum biomarkers. We designed a standard protocol for the glycoblotting combined with MALDI-TOFMS to perform rapid and quantitative profiling of the glycan parts of glycoproteins (N-glycans) and glycosphingolipids (GSLs) using human AD's post-mortem samples such as brain tissues (dissected cerebral cortices such as frontal, parietal, occipital, and temporal domains), serum and cerebrospinal fluid (CSF). The structural profiles of the major N-glycans released from glycoproteins and the total expression levels of the glycans were found to be mostly similar between the brain tissues of the AD patients and those of the normal control group. In contrast, the expression levels of the serum and CSF protein N-glycans such as bisect-type and multiply branched glycoforms were increased significantly in AD patient group. In addition, the levels of some gangliosides such as GM1, GM2 and GM3 appeared to alter in the AD patient brain and serum samples when compared with the normal control groups. Alteration of the expression levels of major N- and GSL-glycans in human brain tissues, serum and CSF of AD patients can be monitored quantitatively by means of the glycoblotting-based standard protocols. The changes in the expression levels of the glycans derived from the human post-mortem samples uncovered by the standardized glycoblotting method provides potential serum biomarkers in central nervous system disorders and can contribute to the insight into the molecular mechanisms in the pathogenesis of neurodegenerative diseases and future drug discovery. Most importantly, the present preliminary trials using human post-mortem samples of AD patients suggest that large-scale serum glycomics cohort by means of various-types of human AD patients as well as the normal control sera can facilitate the discovery research of highly sensitive and reliable serum biomarkers for an early diagnosis of AD. This article is part of a Special Issue entitled "Glycans in personalised medicine" Guest Editor: Professor Gordan Lauc. Copyright © 2016 Elsevier B.V. All rights reserved.
Comparison of serum and plasma measurements of Müllerian inhibiting substance.
Merhi, Zaher O; Messerlian, Geralyn M; Minkoff, Howard; Eklund, Elizabeth E; Macura, Jerzy; Feldman, Joseph; Rodriguez, Carlos; Seifer, David B
2008-06-01
The authors sought to determine whether measurement of plasma Müllerian inhibiting substance (MIS) is a suitable substitute for measurement of serum MIS. Eighteen samples of serum and plasma were examined that were drawn simultaneously. Levels of MIS were measured with an ELISA kit, and plasma levels were studied in parallel to serum samples. A 98.5% correlation was found between serum and plasma MIS values.
Prevalence and causes of abnormal PSA recovery.
Lautenbach, Noémie; Müntener, Michael; Zanoni, Paolo; Saleh, Lanja; Saba, Karim; Umbehr, Martin; Velagapudi, Srividya; Hof, Danielle; Sulser, Tullio; Wild, Peter J; von Eckardstein, Arnold; Poyet, Cédric
2018-01-26
Prostate-specific antigen (PSA) test is of paramount importance as a diagnostic tool for the detection and monitoring of patients with prostate cancer. In the presence of interfering factors such as heterophilic antibodies or anti-PSA antibodies the PSA test can yield significantly falsified results. The prevalence of these factors is unknown. We determined the recovery of PSA concentrations diluting patient samples with a standard serum of known PSA concentration. Based on the frequency distribution of recoveries in a pre-study on 268 samples, samples with recoveries <80% or >120% were defined as suspect, re-tested and further characterized to identify the cause of interference. A total of 1158 consecutive serum samples were analyzed. Four samples (0.3%) showed reproducibly disturbed recoveries of 10%, 68%, 166% and 4441%. In three samples heterophilic antibodies were identified as the probable cause, in the fourth anti-PSA-autoantibodies. The very low recovery caused by the latter interference was confirmed in serum, as well as heparin- and EDTA plasma of blood samples obtained 6 months later. Analysis by eight different immunoassays showed recoveries ranging between <10% and 80%. In a follow-up study of 212 random plasma samples we found seven samples with autoantibodies against PSA which however did not show any disturbed PSA recovery. About 0.3% of PSA determinations by the electrochemiluminescence assay (ECLIA) of Roche diagnostics are disturbed by heterophilic or anti-PSA autoantibodies. Although they are rare, these interferences can cause relevant misinterpretations of a PSA test result.
Differential expression profiling of serum proteins and metabolites for biomarker discovery
NASA Astrophysics Data System (ADS)
Roy, Sushmita Mimi; Anderle, Markus; Lin, Hua; Becker, Christopher H.
2004-11-01
A liquid chromatography-mass spectrometry (LC-MS) proteomics and metabolomics platform is presented for quantitative differential expression analysis. Proteome profiles obtained from 1.5 [mu]L of human serum show ~5000 de-isotoped and quantifiable molecular ions. Approximately 1500 metabolites are observed from 100 [mu]L of serum. Quantification is based on reproducible sample preparation and linear signal intensity as a function of concentration. The platform is validated using human serum, but is generally applicable to all biological fluids and tissues. The median coefficient of variation (CV) for ~5000 proteomic and ~1500 metabolomic molecular ions is approximately 25%. For the case of C-reactive protein, results agree with quantification by immunoassay. The independent contributions of two sources of variance, namely sample preparation and LC-MS analysis, are respectively quantified as 20.4 and 15.1% for the proteome, and 19.5 and 13.5% for the metabolome, for median CV values. Furthermore, biological diversity for ~20 healthy individuals is estimated by measuring the variance of ~6500 proteomic and metabolomic molecular ions in sera for each sample; the median CV is 22.3% for the proteome and 16.7% for the metabolome. Finally, quantitative differential expression profiling is applied to a clinical study comparing healthy individuals and rheumatoid arthritis (RA) patients.
Serum proteomics reveals systemic dysregulation of innate immunity in type 1 diabetes
Fillmore, Thomas L.; Schepmoes, Athena A.; Clauss, Therese R.W.; Gritsenko, Marina A.; Mueller, Patricia W.; Rewers, Marian; Atkinson, Mark A.; Smith, Richard D.
2013-01-01
Using global liquid chromatography-mass spectrometry (LC-MS)–based proteomics analyses, we identified 24 serum proteins that were significantly variant between those with type 1 diabetes (T1D) and healthy controls. Functionally, these proteins represent innate immune responses, the activation cascade of complement, inflammatory responses, and blood coagulation. Targeted verification analyses were performed on 52 surrogate peptides representing these proteins, with serum samples from an antibody standardization program cohort of 100 healthy control and 50 type 1 diabetic subjects. 16 peptides were verified as having very good discriminating power, with areas under the receiver operating characteristic curve ≥0.8. Further validation with blinded serum samples from an independent cohort (10 healthy control and 10 type 1 diabetics) demonstrated that peptides from platelet basic protein and C1 inhibitor achieved both 100% sensitivity and 100% specificity for classification of samples. The disease specificity of these proteins was assessed using sera from 50 age-matched type 2 diabetic individuals, and a subset of proteins, C1 inhibitor in particular, were exceptionally good discriminators between these two forms of diabetes. The panel of biomarkers distinguishing those with T1D from healthy controls and those with type 2 diabetes suggests that dysregulated innate immune responses may be associated with the development of this disorder. PMID:23277452
Ramon-Marquez, Teresa; Medina-Castillo, Antonio L; Fernandez-Gutierrez, Alberto; Fernandez-Sanchez, Jorge F
2016-08-15
This paper describes a novel biosensor which combines the use of nanotechnology (non-woven nanofibre mat) with Solid Surface-Room Temperature Phosphorescence (SS-RTP) measurement for the determination of serotonin in human serum. The developed biosensor is simple and can be directly applied in serum; only requires a simple clean-up protocol. Therefore it is the first time that serotonin is analysed directly in serum with a non-enzymatic technique. This new approach is based on the covalent immobilization of serotonin directly from serum on a functional nanofibre material (Tiss®-Link) with a preactivated surface for direct covalent immobilization of primary and secondary amines, and the subsequent measurement of serotonin phosphorescent emission from the solid surface. The phosphorescent detection allows avoiding the interference from any fluorescence emission or scattering light from any molecule present in the serum sample which can be also immobilised on the nanofibre material. The determination of serotonin with this SS-RTP sensor overcomes some limitations, such as large interference from the matrix and high cost and complexity of many of the methods widely used for serotonin analysis. The potential applicability of the sensor in the clinical diagnosis was demonstrated by analysing serum samples from seven healthy volunteers. The method was validated with an external reference laboratory, obtaining a correlation coefficient of 0.997 which indicates excellent correlation between the two methods. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Shaoxin; Zhang, Yanjiao; Xu, Junfa; Li, Linfang; Zeng, Qiuyao; Lin, Lin; Guo, Zhouyi; Liu, Zhiming; Xiong, Honglian; Liu, Songhao
2014-09-01
This study aims to present a noninvasive prostate cancer screening methods using serum surface-enhanced Raman scattering (SERS) and support vector machine (SVM) techniques through peripheral blood sample. SERS measurements are performed using serum samples from 93 prostate cancer patients and 68 healthy volunteers by silver nanoparticles. Three types of kernel functions including linear, polynomial, and Gaussian radial basis function (RBF) are employed to build SVM diagnostic models for classifying measured SERS spectra. For comparably evaluating the performance of SVM classification models, the standard multivariate statistic analysis method of principal component analysis (PCA) is also applied to classify the same datasets. The study results show that for the RBF kernel SVM diagnostic model, the diagnostic accuracy of 98.1% is acquired, which is superior to the results of 91.3% obtained from PCA methods. The receiver operating characteristic curve of diagnostic models further confirm above research results. This study demonstrates that label-free serum SERS analysis technique combined with SVM diagnostic algorithm has great potential for noninvasive prostate cancer screening.
Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.
Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto
2017-04-01
Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Christiansen, Anders; Kringelum, Jens V; Hansen, Christian S; Bøgh, Katrine L; Sullivan, Eric; Patel, Jigar; Rigby, Neil M; Eiwegger, Thomas; Szépfalusi, Zsolt; de Masi, Federico; Nielsen, Morten; Lund, Ole; Dufva, Martin
2015-08-06
Phage display is a prominent screening technique with a multitude of applications including therapeutic antibody development and mapping of antigen epitopes. In this study, phages were selected based on their interaction with patient serum and exhaustively characterised by high-throughput sequencing. A bioinformatics approach was developed in order to identify peptide motifs of interest based on clustering and contrasting to control samples. Comparison of patient and control samples confirmed a major issue in phage display, namely the selection of unspecific peptides. The potential of the bioinformatic approach was demonstrated by identifying epitopes of a prominent peanut allergen, Ara h 1, in sera from patients with severe peanut allergy. The identified epitopes were confirmed by high-density peptide micro-arrays. The present study demonstrates that high-throughput sequencing can empower phage display by (i) enabling the analysis of complex biological samples, (ii) circumventing the traditional laborious picking and functional testing of individual phage clones and (iii) reducing the number of selection rounds.
Effect of Repeated Freezing and Thawing on 18 Clinical Chemistry Analytes in Rat Serum
Kale, Vijay P; Patel, Sweta G; Gunjal, Prashant S; Wakchaure, Santosh U; Sundar, Rajesh S; Ranvir, Ramchandra K; Jain, Mukul R
2012-01-01
In a preclinical research laboratory, using serum samples that have been frozen and thawed repeatedly is sometimes unavoidable when needing to confirm previous results or perform additional analysis. Here we determined the effects of multiple cycles of refrigeration or freezing and thawing of rat serum at 3 temperature conditions for different storage times on clinical chemistry analytes. Serum samples obtained from adult Wistar rats were stored at 2 to 8 °C and −10 to −20 °C for as long as 72 h and at −70 °C for as long as 30 d. At different time points (24, 48, and 72 h for samples stored at 2 to 8 °C or −10 to −20 °C and 1, 7, and 30 d for samples stored at −70 °C), the samples were brought to room temperature, analyzed, and then stored again at the designated temperature. The results obtained after each storage cycle were compared with those obtained from the initial analysis of fresh samples. Of the 18 serum analytes evaluated, 14 were stable without significant changes, even after 3 freeze–thaw cycles at the tested temperature ranges. Results from this study will help researchers working with rat serum to interpret the biochemical data obtained from serum samples that have been frozen and thawed repeatedly. PMID:23043814
Serum protein measurement using a tapered fluorescent fibre-optic evanescent wave-based biosensor
NASA Astrophysics Data System (ADS)
Preejith, P. V.; Lim, C. S.; Chia, T. F.
2006-12-01
A novel method to measure the total serum protein concentration is described in this paper. The method is based on the principles of fibre-optic evanescent wave spectroscopy. The biosensor applies a fluorescent dye-immobilized porous glass coating on a multi-mode optical fibre. The evanescent wave's intensity at the fibre-optic core-cladding interface is used to monitor the protein-induced changes in the sensor element. The sensor offers a rapid, single-step method for quantifying protein concentrations without destroying the sample. This unique sensing method presents a sensitive and accurate platform for the quantification of protein.
Measurement of rivaroxaban and apixaban in serum samples of patients
Harenberg, Job; Krämer, Sandra; Du, Shanshan; Zolfaghari, Shabnam; Schulze, Astrid; Krämer, Roland; Weiss, Christel; Wehling, Martin; Lip, Gregory Y H
2014-01-01
Background The determination of rivaroxaban and apixaban from serum samples of patients may be beneficial in specific clinical situations when additional blood sampling for plasma and thus the determination of factor Xa activity is not feasible or results are not plausible. Materials and methods The primary aim of this study was to compare the concentrations of rivaroxaban and apixaban in serum with those measured in plasma. Secondary aims were the performance of three different chromogenic methods and concentrations in patients on treatment with rivaroxaban 10 mg od (n = 124) or 20 mg od (n = 94) or apixaban 5 mg bid (n = 52) measured at different time. Results Concentrations of rivaroxaban and apixaban in serum were about 20–25% higher compared with plasma samples with a high correlation (r = 0·79775–0·94662) using all assays (all P < 0·0001). The intraclass correlation coefficients were about 0·90 for rivaroxaban and 0·55 for apixaban. Mean rivaroxaban concentrations were higher at 2 and 3 h compared with 1 and 12 h after administration measured from plasma and serum samples (all P-values < 0·05) and were not different between 1 vs. 12 h (plasma and serum). Conclusions The results indicate that rivaroxaban and apixaban concentrations can be determined specifically from serum samples. PMID:24931429
A bacterial engineered glycoprotein as a novel antigen for diagnosis of bovine brucellosis.
Ciocchini, Andrés E; Serantes, Diego A Rey; Melli, Luciano J; Guidolin, Leticia S; Iwashkiw, Jeremy A; Elena, Sebastián; Franco, Cristina; Nicola, Ana M; Feldman, Mario F; Comerci, Diego J; Ugalde, Juan E
2014-08-27
Brucellosis is a highly contagious zoonosis that affects livestock and human beings. Laboratory diagnosis of bovine brucellosis mainly relies on serological diagnosis using serum and/or milk samples. Although there are several serological tests with different diagnostic performance and capacity to differentiate vaccinated from infected animals, there is still no standardized reference antigen for the disease. Here we validate the first recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of bovine brucellosis. This antigen can be produced in homogeneous batches without the need of culturing pathogenic brucellae; all characteristics that make it appropriate for standardization. An indirect immunoassay based on the detection of anti O-polysaccharide IgG antibodies in bovine samples was developed coupling OAg-AcrA to magnetic beads or ELISA plates. As a proof of concept and to validate the antigen, we analyzed serum, whole blood and milk samples obtained from non-infected, experimentally infected and vaccinated animals included in a vaccination/infection trial performed in our laboratory as well as more than 1000 serum and milk samples obtained from naturally infected and S19-vaccinated animals from Argentina. Our results demonstrate that OAg-AcrA-based assays are highly accurate for diagnosis of bovine brucellosis, even in vaccinated herds, using different types of samples and in different platforms. We propose this novel recombinant glycoprotein as an antigen suitable for the development of new standard immunological tests for screening and confirmatory diagnosis of bovine brucellosis in regions or countries with brucellosis-control programs. Copyright © 2014 Elsevier B.V. All rights reserved.
Palladium modified porous silicon as multi-functional MALDI chip for serum peptide detection.
Li, Xiao; Chen, Xiaoming; Tan, Jie; Liang, Xiao; Wu, Jianmin
2017-02-14
Interest in using mesoporous materials for peptidomic research has increased recently. The present study reports a new type of matrix assisted laser desorption/ionization (MALDI) plate derived from electrochemically etched porous silicon (PSi) whose surface was modified with palladium nanoparticles (PdNPs). Owing to the well-tailored pore size and the molecular filtration effect of the PSi, peptides in serum samples can be selectively captured and enriched in the pore channel, thereby eliminating the interference from large proteins in subsequent MALDI-MS detection. On the other hand, the PdNPs with localized surface plasmon resonance (LSPR) effect can help to enhance the efficiency of energy absorption in the UV region. Meanwhile, the charge separation effect between the PSi semiconductor and PdNPs also can be applied to promote the accumulation of positive charges on PdNPs, resulting in an improvement in laser desorption/ionization (LDI) efficiency under positive linear detection mode. The interplay among these unique properties of PSi and PdNPs can synergistically increase the overall sensitivity in serum peptide detection. Using this technology, serum sample can be directly detected on the PSi-PdNPs chip without complicated pretreatment process. Therefore, a high fidelity serum peptide fingerprint can be acquired in a high throughput way. With the assistance of statistical analysis, colorectal cancer patients and healthy people can be accurately distinguished based on the serum peptide fingerprints.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Ying; Lin, Lianjie; Xu, Yanbin
2013-04-19
Highlights: •Twenty ulcerative colitis patients and nineteen healthy controls were enrolled. •Increased 3-hydroxybutyrate, glucose, phenylalanine, and decreased lipid were found. •We report early stage diagnosis of ulcerative colitis using NMR-based metabolomics. -- Abstract: Ulcerative colitis (UC) has seriously impaired the health of citizens. Accurate diagnosis of UC at an early stage is crucial to improve the efficiency of treatment and prognosis. In this study, proton nuclear magnetic resonance ({sup 1}H NMR)-based metabolomic analysis was performed on serum samples collected from active UC patients (n = 20) and healthy controls (n = 19), respectively. The obtained spectral profiles were subjected tomore » multivariate data analysis. Our results showed that consistent metabolic alterations were present between the two groups. Compared to healthy controls, UC patients displayed increased 3-hydroxybutyrate, β-glucose, α-glucose, and phenylalanine, but decreased lipid in serum. These findings highlight the possibilities of NMR-based metabolomics as a non-invasive diagnostic tool for UC.« less
Estrogen levels in serum and urine of vegetarian and omnivore premenopausal women
Harmon, Brook; Morimoto, Yukiko; Beckford, Fanchon; Franke, Adrian A.; Stanczyk, Frank Z.; Maskarinec, Gertraud
2014-01-01
Objective Based on the hypothesis that high-meat diets may increase breast cancer risk through hormonal pathways, this analysis compared estrogens in serum and urine by meat-eating status. Design Intervention with repeated measures. Setting Two randomized soy trials (BEAN1 and BEAN2) among premenopausal healthy women. Subjects BEAN1 participants completed 7 unannounced 24-hour dietary recalls and donated 5 blood and urine samples over 2 years. BEAN2 women provided 7 recalls and 3 samples over 13 months. Serum samples were analyzed for estrone (E1) and estradiol (E2) using radioimmunoassays. Nine estrogen metabolites were measured in urine by liquid chromatography mass spectrometry. Semi-vegetarians included women who reported <30 g/day of red meat, poultry, and fish and pescatarians who consumed <20 g/day of meat/poultry but >10 g/day of fish. All other women were classified as non-vegetarians. We applied mixed models to compute least-square means by vegetarian status adjusted for potential confounders. Results The mean age of the 272 participants was 41.9±4.5 years. Serum E1 (85 vs 100 pg/mL, p=0.04) and E2 (140 vs 154 pg/mL, p=0.04) levels were lower in the 37 semi-vegetarians than in the 235 non-vegetarians. The sum of the 9 urinary estrogen metabolites (183 vs 200 pmol/mg creatinine, p=0.27) and the proportions of individual estrogens and pathways did not differ by meat-eating status. Restricting the models to the samples collected during the luteal phase strengthened the associations. Conclusions Given the limitations of this study, the lower levels of serum estrogens in semi-vegetarians than non-vegetarians need confirmation in larger populations. PMID:24050121
Lam, Virginie; Albrecht, Matthew A; Takechi, Ryusuke; Prasopsang, Prachya; Lee, Ya Ping; Foster, Jonathan K; Mamo, John C L
2016-06-01
There is increasing evidence supporting an association of higher serum vitamin D concentration with better cognitive performance in older individuals. However, to date, consideration of the putative association between vitamin D and cognition has been based principally on studies investigating clinical participant samples manifesting vitamin D deficiency, particularly in older people. Moreover, relationships between vitamin D and cognition are typically not considered in the context of counter-regulatory calcium-modulating hormones or calcium homeostasis. Serum vitamin D/bioactive (ionised) calcium/parathyroid hormone homeostasis was considered in the context of cognitive performance in healthy, middle-aged and older individuals. A cross-sectional sample of 179 participants between the ages of 47-84 years was recruited for this study (114 females, 65 males). Participants provided fasting blood samples for analysis of serum 25-hydroxyvitamin D levels, ionised calcium (iCa) and parathyroid hormone (PTH) and completed cognitive measures of verbal episodic learning and memory. Serum 25-hydroxyvitamin D concentrations were negatively associated (with and without covariates of age, gender, depression and NART scores, iCa, and PTH) with measures of verbal episodic learning and memory, in particular with trial 5 of the Rey Auditory Verbal Learning Test (RAVLT) and long-delay free recall on the RAVLT. Overall, the findings from this study suggest an association between higher vitamin D status and poorer performance on verbal episodic memory in middle-aged and older individuals with normal vitamin D-calcium-PTH homeostasis. Despite requiring replication in other participant samples, this is a potentially important finding as it indicates that it may not be beneficial from a cognitive perspective to provide vitamin D supplements in individuals with already adequate vitamin D status.
Diesel, Alison; DeBoer, Douglas J
2011-02-01
Feline and canine atopic dermatitis are thought to have a similar immunopathogenesis. As with dogs, detection of allergen-specific IgE in cat serum merely supports a diagnosis of feline atopy based on compatible history, clinical signs and elimination of other pruritic dermatoses. In this study, a rapid screening immunoassay (Allercept(®) E-Screen 2nd Generation; Heska AG, Fribourg, Switzerland; ES2G) was compared with a complete-panel serum allergen-specific IgE assay (Allercept(®); Heska AG; CP) in healthy cats with no history of skin disease and in atopic cats. The latter had no diagnosis of external parasitism, infection, food hypersensitivity or other skin disease explaining their pruritus, and expressed cutaneous reaction patterns typically associated with feline allergic skin disease (head, neck or pinnal pruritus, miliary dermatitis, self-induced alopecia, eosinophilic granuloma complex). The proportion of cats positive on either the ES2G or the CP assays was not significantly different between the atopic and healthy cat groups. There was, however, strong agreement between the results of the ES2G and CP assay; overall, the two tests were in agreement for 43 of 49 (88%) serum samples. There was also strong agreement when individual allergen groups were evaluated (agreement noted: indoor, 41 of 49 samples; grasses/weeds, 37 of 49 samples; and trees, 41 of 49 samples). These results indicate that although neither test is diagnostic for feline atopic dermatitis, the screening assay is beneficial for predicting the results of a complete-panel serum allergen-specific IgE assay in cats. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.
Borte, Stephan; Janzi, Magdalena; Pan-Hammarström, Qiang; von Döbeln, Ulrika; Nordvall, Lennart; Winiarski, Jacek; Fasth, Anders; Hammarström, Lennart
2012-01-01
There is a need for neonatal screening tools to improve the long-term clinical outcome of patients with primary immunodeficiency diseases (PID). Recently, a PCR-based screening method for both TRECs and KRECs using Guthrie card samples has been developed. However, the applicability of these excision circle assays is limited to patients with severe T or B cell lymphopenia (SCID, XLA and A-T), whereas the most common forms of PID are not detected. Absence of serum IgA is seen in a major fraction of patients with immunological defects. As serum IgA in newborns is considered to be of fetal origin, eluates from routinely collected dried blood spot samples might thus be suitable for identification of children with PID. To assess the applicability of such screening assays, stored Guthrie card samples were obtained from 47 patients with various forms of primary immunodeficiency diseases (SCID, XLA, A-T, HIGM and IgAD), 20 individuals with normal serum IgA levels born to IgA-deficient mothers and 51 matched healthy newborns. Surprisingly, normal serum IgA levels were found in all SCID, XLA, A-T and HIGM patients and, additionally, in all those IgAD patients born to IgA-sufficient mothers. Conversely, no serum IgA was found in any of the 16 IgAD patients born by IgA-deficient mothers. Moreover, half of the IgA-sufficient individuals born by IgA-deficient mothers also lacked IgA at birth whereas no IgA-deficient individuals were found among the controls. IgA in neonatal dried blood samples thus appears to be of both maternal and fetal origin and precludes its use as a reliable marker for neonatal screening of primary immunodeficiency diseases. PMID:22916257
Borte, Stephan; Janzi, Magdalena; Pan-Hammarström, Qiang; von Döbeln, Ulrika; Nordvall, Lennart; Winiarski, Jacek; Fasth, Anders; Hammarström, Lennart
2012-01-01
There is a need for neonatal screening tools to improve the long-term clinical outcome of patients with primary immunodeficiency diseases (PID). Recently, a PCR-based screening method for both TRECs and KRECs using Guthrie card samples has been developed. However, the applicability of these excision circle assays is limited to patients with severe T or B cell lymphopenia (SCID, XLA and A-T), whereas the most common forms of PID are not detected. Absence of serum IgA is seen in a major fraction of patients with immunological defects. As serum IgA in newborns is considered to be of fetal origin, eluates from routinely collected dried blood spot samples might thus be suitable for identification of children with PID. To assess the applicability of such screening assays, stored Guthrie card samples were obtained from 47 patients with various forms of primary immunodeficiency diseases (SCID, XLA, A-T, HIGM and IgAD), 20 individuals with normal serum IgA levels born to IgA-deficient mothers and 51 matched healthy newborns. Surprisingly, normal serum IgA levels were found in all SCID, XLA, A-T and HIGM patients and, additionally, in all those IgAD patients born to IgA-sufficient mothers. Conversely, no serum IgA was found in any of the 16 IgAD patients born by IgA-deficient mothers. Moreover, half of the IgA-sufficient individuals born by IgA-deficient mothers also lacked IgA at birth whereas no IgA-deficient individuals were found among the controls. IgA in neonatal dried blood samples thus appears to be of both maternal and fetal origin and precludes its use as a reliable marker for neonatal screening of primary immunodeficiency diseases.
Vera-Candioti, Luciana; Culzoni, María J; Olivieri, Alejandro C; Goicoechea, Héctor C
2008-11-01
Drug monitoring in serum samples was performed using second-order data generated by CE-DAD, processed with a suitable chemometric strategy. Carbamazepine could be accurately quantitated in the presence of its main metabolite (carbamazepine epoxide), other therapeutic drugs (lamotrigine, phenobarbital, phenytoin, phenylephrine, ibuprofen, acetaminophen, theophylline, caffeine, acetyl salicylic acid), and additional serum endogenous components. The analytical strategy consisted of the following steps: (i) serum sample clean-up to remove matrix interferences, (ii) data pre-processing, in order to reduce the background and to correct for electrophoretic time shifts, and (iii) resolution of fully overlapped CE peaks (corresponding to carbamazepine, its metabolite, lamotrigine and unexpected serum components) by the well-known multivariate curve resolution-alternating least squares algorithm, which extracts quantitative information that can be uniquely ascribed to the analyte of interest. The analyte concentration in serum samples ranged from 2.00 to 8.00 mg/L. Mean recoveries were 102.6% (s=7.7) for binary samples, and 94.8% (s=13.5) for spiked serum samples, while CV (%)=4.0 was computed for five replicate, indicative of the acceptable accuracy and precision of the proposed method.
NASA Astrophysics Data System (ADS)
Azizah, N.; Hashim, U.; Nadzirah, Sh.; Arshad, M. K. Md; Ruslinda, A. R.; Gopinath, Subash C. B.
2017-03-01
The affectability and unwavering quality of PCR for indicative and research purposes require effective fair systems of extraction and sanitization of nucleic acids. One of the real impediments of PCR-based tests is the hindrance of the enhancement procedure by substances exhibit in clinical examples. This examination considers distinctive techniques for extraction and cleaning of viral DNA from serum tests in view of recuperation productivity as far as yield of DNA and rate recouped immaculateness of removed DNA, and rate of restraint. The best extraction strategies were the phenol/chloroform strategy and the silica gel extraction methodology for serum tests, individually. Considering DNA immaculateness, extraction technique by utilizing the phenol/chloroform strategy delivered the most tasteful results in serum tests contrasted with the silica gel, separately. The nearness of inhibitors was overcome by all DNA extraction strategies in serum tests, as confirm by semiquantitative PCR enhancement.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-01-01
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70–200 mg/dL), revealing high system performance for a wide glycemic state range (45–500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting. PMID:27669267
Voge, Natalia V.; Perera, Rushika; Mahapatra, Sebabrata; Gresh, Lionel; Balmaseda, Angel; Loroño-Pino, María A.; Hopf-Jannasch, Amber S.; Belisle, John T.; Harris, Eva; Blair, Carol D.; Beaty, Barry J.
2016-01-01
Background Epidemic dengue fever (DF) and dengue hemorrhagic fever/dengue shock syndrome (DHF/DSS) are overwhelming public health capacity for diagnosis and clinical care of dengue patients throughout the tropical and subtropical world. The ability to predict severe dengue disease outcomes (DHF/DSS) using acute phase clinical specimens would be of enormous value to physicians and health care workers for appropriate triaging of patients for clinical management. Advances in the field of metabolomics and analytic software provide new opportunities to identify host small molecule biomarkers (SMBs) in acute phase clinical specimens that differentiate dengue disease outcomes. Methodology/Principal Findings Exploratory metabolomic studies were conducted to characterize the serum metabolome of patients who experienced different dengue disease outcomes. Serum samples from dengue patients from Nicaragua and Mexico were retrospectively obtained, and hydrophilic interaction liquid chromatography (HILIC)-mass spectrometry (MS) identified small molecule metabolites that were associated with and statistically differentiated DHF/DSS, DF, and non-dengue (ND) diagnosis groups. In the Nicaraguan samples, 191 metabolites differentiated DF from ND outcomes and 83 differentiated DHF/DSS and DF outcomes. In the Mexican samples, 306 metabolites differentiated DF from ND and 37 differentiated DHF/DSS and DF outcomes. The structural identities of 13 metabolites were confirmed using tandem mass spectrometry (MS/MS). Metabolomic analysis of serum samples from patients diagnosed as DF who progressed to DHF/DSS identified 65 metabolites that predicted dengue disease outcomes. Differential perturbation of the serum metabolome was demonstrated following infection with different DENV serotypes and following primary and secondary DENV infections. Conclusions/Significance These results provide proof-of-concept that a metabolomics approach can be used to identify metabolites or SMBs in serum specimens that are associated with distinct DENV infections and disease outcomes. The differentiating metabolites also provide insights into metabolic pathways and pathogenic and immunologic mechanisms associated with dengue disease severity. PMID:26913918
Serological evidence for the presence of influenza D virus in small ruminants.
Quast, Megan; Sreenivasan, Chithra; Sexton, Gabriel; Nedland, Hunter; Singrey, Aaron; Fawcett, Linda; Miller, Grant; Lauer, Dale; Voss, Shauna; Pollock, Stacy; Cunha, Cristina W; Christopher-Hennings, Jane; Nelson, Eric; Li, Feng
2015-11-18
Influenza D virus (FLUDV) was isolated from diseased pigs with respiratory disease symptoms in 2011, and since then the new virus has also been spread to cattle. Little is known about the susceptibility of other agricultural animals and poultry to FLUDV. This study was designed to determine if other farm animals such as goats, sheep, chickens, and turkey are possible hosts to this newly emerging influenza virus. 648 goat and sheep serum samples and 250 chicken and turkey serum samples were collected from 141 small ruminant and 25 poultry farms from different geographical locations in the United States and Canada. Serum samples were examined using the hemagglutination inhibition (HI) assay and the sheep and goat samples were further analyzed using the serum neutralization assay. Results of this study showed FLUDV antibodies were detected in 13.5% (17/126) of the sampled sheep farms, and 5.2% (29/557) of tested sheep serum samples were positive for FLUDV antibodies. For the goat results, the FLUDV antibodies were detected in 13.3% (2/15) of the sampled farms, and 8.8% (8/91) of the tested goat serum samples were positive for FLUDV antibodies. Furthermore, all tested poultry serum samples were negative for FLUDV antibodies. Our data demonstrated that sheep and goat are susceptible to FLUDV virus and multiple states in U.S. have this virus infection already in these two species. This new finding highlights a need for future surveillance of FLUDV virus in small ruminants toward better understanding both the origin and natural reservoir of this new virus. Copyright © 2015 Elsevier B.V. All rights reserved.
Ke, Yuyong; Gonthier, Renaud; Labrie, Fernand
2017-05-01
In the present study, the impact of the extraction solvent on the accuracy of endogenous progesterone assay in human serum has been investigated using two selective reaction monitoring (SRM) transitions (315>97 & 315>109). Higher levels of noise and more interference were observed when more polar solvents were used for extraction, thus resulting in serious bias of the measured values of progesterone in serum. This is confirmed by monitoring the ion ratio of 315>97-315>109. This issue could not be easily resolved by changes in MS/MS transitions or chromatography conditions. More bias was observed with the SRM transition 315>109 for the polar solvent extraction. Hexane and 1-chlorobutane (polarity index of 0 and 1, respectively) did provide the cleanest samples with a lower noise level in the chromatograms. Moreover, the measured values of progesterone were not changed with different SRM transitions or longer retention time in search of an improved separation. Recovery tests of progesterone have been performed with 1-chlorobutane in matrices with phosphate buffered saline (PBS) 1x, PBS 1×3% bovine serum albumin (BSA), stripped serum/H 2 O (1:1) and unstripped serum. The recovery (70%∼80%) consistency is observed not only at different levels but also in different matrices. The equivalent recovery between PBS 1x, PBS 1×3% BSA and unstripped serum shows that the impact of progesterone binding to serum proteins on the measurement accuracy can be avoided with this sample preparation procedure. No significant matrix effect on the determination of progesterone was observed with 1-chlorobutane. Within the range of 12.5-2000pg/mL, a good linearity is observed with R>0.99 and weighting factor 1/X. Bias and covariance efficiency of QCs are within 10%. With 1-chlorobutane as the extraction solvent, the concentration of progesterone was measured where the range for postmenopausal serum is 5.74∼91.7pg/mL, which is well below the reported concentrations of 314 pg/mL∼942pg/mL in postmenopausal serum by immunoassay-based techniques, while the range in premenopausal serum is 12.8 pg/mL∼18.6ng/mL. Copyright © 2017 Elsevier B.V. All rights reserved.
Panyasing, Y; Goodell, C K; Wang, C; Kittawornrat, A; Prickett, J R; Schwartz, K J; Ballagi, A; Lizano, S; Zimmerman, J J
2014-04-01
In commercial swine populations, influenza is an important component of the porcine respiratory disease complex (PRDC) and a pathogen with major economic impact. Previously, a commercial blocking ELISA (FlockChek(™) Avian Influenza Virus MultiS-Screen(®) Antibody Test Kit, IDEXX Laboratories, Inc., Westbrook, ME, USA) designed to detect influenza A nucleoprotein (NP) antibodies in avian serum was shown to accurately detect NP antibodies in swine serum. The purpose of this study was to determine whether this assay could detect NP antibodies in swine oral fluid samples. Initially, the procedure for performing the NP-blocking ELISA on oral fluid was modified from the serum testing protocol by changing sample dilution, sample volume, incubation time and incubation temperature. The detection of NP antibody was then evaluated using pen-based oral fluid samples (n = 182) from pigs inoculated with either influenza A virus subtype H1N1 or H3N2 under experimental conditions and followed for 42 days post inoculation (DPI). NP antibodies in oral fluid were detected from DPI 7 to 42 in all inoculated groups, that is, the mean sample-to-negative (S/N) ratio of influenza-inoculated pigs was significantly different (P < 0.0001) from uninoculated controls (unvaccinated or vaccinated-uninoculated groups) through this period. Oral fluid versus serum S/N ratios from the same pen showed a correlation of 0.796 (Pearson's correlation coefficient, P < 0.0001). The results showed that oral fluid samples from influenza virus-infected pigs contained detectable levels of NP antibodies for ≥42 DPI. Future research will be required to determine whether this approach could be used to monitor the circulation of influenza virus in commercial pig populations. © 2012 Blackwell Verlag GmbH.
Simioni, Andreza Ribeiro; Rodrigues, Marcilene M A; Primo, Fernando L; Morais, Paulo C; Tedesco, Antonio Claudio
2011-04-01
This study reports on the development and characterization of bovine serum albumin (BSA) nanospheres containing Silicon(IV) phthalocyanine (NzPc) and/or maghemite nanoparticles (MNP), the latter introduced via ionic magnetic fluid (MF). The nanosized BSA-loaded samples were designed for synergic application while combining Photodynamic Therapy and Hyperthermia. Incorporation of MNP in the albumin-based template, allowing full control of the magnetic content, was accomplished by adding a highly-stable ionic magnetic fluid sample to the albumin suspension, following heat denaturing. The material's evaluation was performed using Zeta potential measurements and scanning electron microscopy. The samples were characterized by steady-state techniques and time-resolved fluorescence. The in vitro assay, using human fibroblasts, revealed no cytotoxic effect in all samples investigated, demonstrating the potential of the tested system as a synergistic drug delivery system.
Winter, P; Hochsteiner, W; Chizzola, R
2004-10-01
In a herd of German Improved Fawn breed of goat in the year 2000 neonatal kid losses due to congenital copper deficiencies were observed. To clarify the problems and to prevent losses in the next breeding season serum copper levels of 10 dams and four control Boer goats were investigated at four time points during one year. Additionally ten kids of the following year were sampled and the serum copper levels were studied. Immediatly after parturition and 8 weeks later the dams showed low serum copper levels (10.4 +/- 11.1 micromol/l, 5.7 +/- 2.9 micromol/l resp.). At the end of the pasture season an increase of serum copper could be measured (19.3 +/- 16.0 micromol/l). To prevent enzootic ataxia due to congenital copper deficiency, the dams were treated with copper oxide wire particles in the next late gestation. At this time point serum copper concentrations started to decrease (18.5 +/- 8.4 micromol/l). The re-examination 3 month later demonstrated an increase of the serum mean copper concentrations up to 23.4 micromol/l in the dams and to 16.2 micromol/l in the kids. The serum copper levels were significantly higher compared to the levels the year before. Big variation of the serum copper levels in the control Boer goats occurred during the year, but no clinical symptoms of copper deficiency could be observed. The copper levels in the grass and soil samples were 6.8 mg/kg and 0.2 mg/kg dry substance, respectively. A secondary copper deficiency based on cadmium could be excluded through the low levels of soil samples. The contents of sulphur and molybdenum were not determined. The results indicate that the German Improved Fawn breed of goats suffered from a primary copper deficiency due to the inefficient mineral supplementation. The administration of Copinox in the last third of the gestation leads to a continious raising of the copper concentrations in the serum and is suited to prevent ataxia due to congential copper deficiency in neonatal kids.
Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus.
Portilho, M M; Mendonça, Acf; Marques, V A; Nabuco, L C; Villela-Nogueira, C A; Ivantes, Cap; Lewis-Ximenez, L L; Lampe, E; Villar, L M
2017-11-01
This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.
Cai, Yu-Chun; Chen, Shao-Hong; Tian, Li-Guang; Chu, Yan-Hong; Lu, Yan; Chen, Mu-Xin; Ai, Lin; Zhou, Yang; Chen, Jia-Xu
2014-02-01
To establish A1E3 and B1C4 monoclonal antibody-based ELISA for detecting circulating antigen of Schistosoma japonicum and explore its application value in the field. The characteristics of A1E3 and B1C4 monoclonal antibodies were analyzed by SDS-PAGE and Western blotting. The SEA-based ELISA was used to evaluate the titers of A1E3 and B1C4. The orthogonal test was used to determine the best concentration of coating antibody B1C4 and optimal working concentration of A1E3-HRP. Under the optimal conditions, the serum samples of 20 acute schistosomiasis cases, 46 chronic schistosomiasis cases, and 20 control sera were tested to evaluate its detection sensitivity and specificity. Seventy-two antibody positive serum samples from Jiangling County of Hubei Province were detected and compared to a commercially available ELISA kit, to evaluate the detection effects of this method. The results of SDS-PAGE demonstrated that the purified A1E3 and B1C4 contained a clear heavy chain with molecular weight of 88,000 and 52,000 respectively and had the same light chain with molecular weight of 20,000; while Western blotting demonstrated that A1E3 and B1C4 could be recognized by SEA and serum samples of acute schistosomiasis cases. The SEA-based ELISA demonstrated the titers of B1C4 and A1E3 were 1:10(5) and 1:30,000, respectively. The serum samples from all the acute cases and 86.9% of the chronic cases showed a positive reaction. All of the control sera from healthy persons gave a negative response. The positive rates of the double monoclonal antibody ELISA and commercial ELISA for detecting the circulating antigen were 45.8% and 43.1% respectively, and there was no significant difference between the results of the two methods. A1E3 and B1C4 monoclonal antibody-based ELISA is established successfully. It exhibits a high sensitivity and specificity in detecting circulating antigen of Schistosoma japonicum.
Centrifugal microfluidic platform for ultrasensitive detection of botulinum toxin
Koh, Chung -Yan; Schaff, Ulrich Y.; Sandstone Diagnostics, Livermore, CA; ...
2014-12-18
In this study, we present an innovative centrifugal microfluidic immunoassay platform (SpinDx) to address the urgent biodefense and public health need for ultrasensitive point-of-care/incident detection of botulinum toxin. The simple, sample-to-answer centrifugal microfluidic immunoassay approach is based on binding of toxins to antibody-laden capture particles followed by sedimentation of the particles through a density-media in a microfluidic disk and quantification by laser-induced fluorescence. A blind, head-to-head comparison study of SpinDx versus the gold-standard mouse bioassay demonstrates 100-fold improvement in sensitivity (limit of detection = 0.09 pg/mL), while achieving total sample-to-answer time of <30 min with 2-μL required volume of themore » unprocessed sample. We further demonstrate quantification of botulinum toxin in both exogeneous (human blood and serum spiked with toxins) and endogeneous (serum from mice intoxicated via oral, intranasal, and intravenous routes) samples. SpinDx can analyze, without any sample preparation, multiple sample types including whole blood, serum, and food. It is readily expandable to additional analytes as the assay reagents (i.e., the capture beads and detection antibodies) are disconnected from the disk architecture and the reader, facilitating rapid development of new assays. SpinDx can also serve as a general-purpose immunoassay platform applicable to diagnosis of other conditions and diseases.« less
Individualized correction of insulin measurement in hemolyzed serum samples.
Wu, Zhi-Qi; Lu, Ju; Chen, Huanhuan; Chen, Wensen; Xu, Hua-Guo
2017-06-01
Insulin measurement plays a key role in the investigation of patients with hypoglycemia, subtype classification of diabetes mellitus, insulin resistance, and impaired beta cell function. However, even slight hemolysis can negatively affect insulin measurement due to RBC insulin-degrading enzyme (IDE). Here, we derived and validated an individualized correction equation in an attempt to eliminate the effects of hemolysis on insulin measurement. The effects of hemolysis on insulin measurement were studied by adding lysed self-RBCs to serum. A correction equation was derived, accounting for both percentage and exposure time of hemolysis. The performance of this individualized correction was evaluated in intentionally hemolyzed samples. Insulin concentration decreased with increasing percentage and exposure time of hemolysis. Based on the effects of hemolysis on insulin measurement of 17 donors (baseline insulin concentrations ranged from 156 to 2119 pmol/L), the individualized hemolysis correction equation was derived: INS corr = INS meas /(0.705lgHb plasma /Hb serum - 0.001Time - 0.612). This equation can revert insulin concentrations of the intentionally hemolyzed samples to values that were statistically not different from the corresponding insulin baseline concentrations (p = 0.1564). Hemolysis could lead to a negative interference on insulin measurement; by individualized hemolysis correction equation for insulin measurement, we can correct and report reliable serum insulin results for a wide range of degrees of sample hemolysis. This correction would increase diagnostic accuracy, reduce inappropriate therapeutic decisions, and improve patient satisfaction with care.
He, Wei-Tao; Liang, Bo-Cheng; Shi, Zhen-Yu; Li, Xu-Yun; Li, Chun-Wen; Shi, Xiao-Lin
2016-01-01
The present study aimed at investigating the weak cation magnetic separation technology and matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) in screening serum protein markers of osteopenia from ten postmenopausal women and ten postmenopausal women without osteopenia as control group, to find a new method for screening biomarkers and establishing a diagnostic model for primary type I osteoporosis. Serum samples were collected from postmenopausal women with osteopenia and postmenopausal women with normal bone mass. Proteins were extracted from serum samples by weak cation exchange magnetic beads technology, and mass spectra acquisition was done by MALDI-TOF-MS. The visualization and comparison of data sets, statistical peak evaluation, model recognition, and discovery of biomarker candidates were handled by the proteinchip data analysis system software(ZJU-PDAS). The diagnostic models were established using genetic arithmetic based support vector machine (SVM). The SVM result with the highest Youden Index was selected as the model. Combinatorial Peaks having the highest accuracy in distinguishing different samples were selected as potential biomarker. From the two group serum samples, a total of 133 differential features were selected. Ten features with significant intensity differences were screened. In the pair-wise comparisons, processing of MALDI-TOF spectra resulted in the identification of ten differential features between postmenopausal women with osteopenia and postmenopausal women with normal bone mass. The difference of features by Youden index showed that the highest features had a mass to charge ratio of 1699 and 3038 Da. A diagnosis model was established with these two peaks as the candidate marker, and the specificity of the model is 100 %, the sensitivity was 90 % by leave-one-out cross validation test. The two groups of specimens in SVM results on the scatter plot could be clearly distinguished. The peak with m/z 3038 in the SVM model was suggested as Secretin by TagIdent tool. To provide further validation, the secretin levels in serum were analyzed using enzyme-linked immunosorbent assays that is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of secretin in human serum.
Pharmacokinetics in lactating women: prediction of alprazolam transfer into milk.
Oo, C Y; Kuhn, R J; Desai, N; Wright, C E; McNamara, P J
1995-01-01
1. Alprazolam, a triazolobenzodiazepine, is extensively prescribed for the treatment of anxiety disorders, which predominantly affect women of child-bearing age. The purpose of the present study was to assess the pharmacokinetics of alprazolam and its two hydroxylated metabolites: 4-hydroxy-alprazolam and alpha-hydroxy-alprazolam in lactating human volunteers and to test the predictability of four recently reported models for drug transfer into milk based on physicochemical properties. 2. Multiple milk and serum samples in eight lactating subjects were collected up to 36 h following single oral doses of 0.5 mg alprazolam; suckling of the infant was discontinued after drug administration. 4-Hydroxy-alprazolam was the predominant metabolite in serum samples while alpha-hydroxy-alprazolam was not detected. 3. The mean oral clearance of alprazolam was 1.15 +/- 0.32 ml min-1 kg-1. The time course of alprazolam in milk roughly paralleled the perspective plasma time profile (mean serum residence time = 16.42 +/- 4.69 h; mean milk residence time = 18.93 +/- 7.03 h). The mean terminal half-life in serum was 12.52 +/- 3.53 h. 4. Observed milk/serum concentration ratios were determined in vivo as AUCmilk/AUCserum (mean M/S(obs) = 0.36 +/- 0.11).(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8527284
NASA Astrophysics Data System (ADS)
Hwang, Kyo Seon; Jeon, Hye Kyung; Lee, Sang-Myung; Kim, Sang Kyung; Kim, Tae Song
2009-05-01
In this study, we describe the application feasibility of a dynamic microcantilever with regard to the detection of a specific protein in human serum or real blood using an end-point analysis. The mechanical response (i.e., resonant frequency) of a functionalized dynamic microcantilever was shown to be altered by molecular interactions, which allowed for the detection of biomolecules present in small quantities without any additional signal enhancements, such as labeling. For the application of the microcantilever sensors to bioassays of serum samples, the mechanical response from the nonspecific adsorption of abundant proteins must be reduced, because it significantly influences the output signal deviation of the microcantilever sensor. We implemented a label-free prostate specific antigen (PSA) detection protocol in standard serum via our established process, which was designed to minimize nonspecific protein adsorption. PSA is a tumor marker for prostate cancer, with a threshold concentration of 2-4 ng/ml (7.2-14.4 pM) for the distinction between patients and normal individuals. The dynamic range of our dynamic microcantilever-based PSA assay on the background of standard serum ranged between 0.1 and 100 ng/ml (3.6 and 3600 pM). It was suggested that the dynamic microcantilever might allow for the sensitive label-free detection of disease markers in an actual human sample.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harima, Yoko, E-mail: harima@takii.kmu.ac.jp; Ikeda, Koshi; Utsunomiya, Keita
Purpose: To determine pretreatment serum protein levels for generally applicable measurement to predict chemoradiation treatment outcomes in patients with locally advanced squamous cell cervical carcinoma (CC). Methods and Materials: In a screening study, measurements were conducted twice. At first, 6 serum samples from CC patients (3 with no evidence of disease [NED] and 3 with cancer-caused death [CD]) and 2 from healthy controls were tested. Next, 12 serum samples from different CC patients (8 NED, 4 CD) and 4 from healthy controls were examined. Subsequently, 28 different CC patients (18 NED, 10 CD) and 9 controls were analyzed in themore » validation study. Protein chips were treated with the sample sera, and the serum protein pattern was detected by surface-enhanced laser desorption and ionization–time-of-flight mass spectrometry (SELDI-TOF MS). Then, single MS-based peptide mass fingerprinting (PMF) and tandem MS (MS/MS)-based peptide/protein identification methods, were used to identify protein corresponding to the detected peak. And then, turbidimetric assay was used to measure the levels of a protein that indicated the best match with this peptide peak. Results: The same peak 8918 m/z was identified in both screening studies. Neither the screening study nor the validation study had significant differences in the appearance of this peak in the controls and NED. However, the intensity of the peak in CD was significantly lower than that of controls and NED in both pilot studies (P=.02, P=.04) and validation study (P=.01, P=.001). The protein indicated the best match with this peptide peak at 8918 m/z was identified as apolipoprotein C-II (ApoC-II) using PMF and MS/MS methods. Turbidimetric assay showed that the mean serum levels of ApoC-II tended to decrease in CD group when compared with NED group (P=.078). Conclusion: ApoC-II could be used as a biomarker for detection in predicting and estimating the radiation treatment outcome of patients with CC.« less
Whitehead, S J; Cornes, M P; Ford, C; Gama, R
2015-01-01
Exclusion of macroprolactinaemia, a well-recognised interference, as the cause of hyperprolactinaemia is essential to avoid potential misdiagnosis and mismanagement of patients. We have derived gender-specific serum total and post-polyethylene glycol (PEG) precipitation monomeric reference ranges for the recently re-standardised Abbott Architect prolactin assay. Prolactin was measured in serum samples obtained from males (n=49) and females (n=52) using the current Abbott Architect immunoassay pre- and post-PEG precipitation. Gender-specific reference ranges were derived for total and monomeric (post-PEG) prolactin. Routine patients' samples (n=175) with a serum total prolactin >700 mIU/L were screened for macroprolactinaemia to assess classification compared with our previous post-PEG precipitation percentage recovery-based approach. Reference ranges for serum total prolactin were 58-419 mIU/L (male) and 63-561 mIU/L (female). Male and female monomeric prolactin reference ranges were 32-309 mIU/L and 39-422 mIU/L, respectively. Mean (SD) post-PEG percentage recovery of the IS 84/500 prolactin standard was 80 (2.3)%. Of 175 patients' samples screened for macroprolactinaemia, 149 had monomeric prolactin concentrations (median monomeric prolactin=1035 mIU/L; median recovery=83%) above the gender-specific reference range. Monomeric prolactin concentrations (median monomeric prolactin=162 mIU/L; median recovery=20%) in the remaining 26 were within the reference ranges. One patient classified as macroprolactin positive and another classified as macroprolactin negative would not have been identified as such using the previous recovery-based approach. The use of post-PEG monomeric reference ranges not only identifies hyperprolactinaemia due solely to macroprolactinaemia but has the added advantage of identifying patients who have simultaneous true monomeric hyperprolactinaemia and elevated concentrations of macroprolactin. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Liang, Si; Xu, Feng; Tang, Weibiao; Zhang, Zheng; Zhang, Wei; Liu, Lili; Wang, Junxia; Lin, Kuangfei
2016-08-01
Hair samples and paired serum samples were collected from e-waste and urban areas in Wenling of Zhejiang Province, China. The PBDE and DBDPE concentrations in hair and serum samples from e-waste workers were significantly higher than those of non-occupational residents and urban residents. BDE209 was the dominating BFRs in hair and serum samples from the e-waste area, while DBDPE was the major BFRs from the urban area. Statistically significant correlations were observed between hair level and serum level for some substances (BDE209, DBDPE, BDE99, BDE47, BDE28, and BDE17), although the PBDE congener profiles in hair were different from those in the serum. A statistically significant positive correlation between the PBDE concentrations and the working age, as well as gender difference, was observed in e-waste workers. Different sources of PBDEs and DBDPE in three groups were identified by principal component analysis and spearman correlation coefficient. Hair is suggested to be a useful matrix for biomonitoring the PBDE exposure in humans.
Litwiniuk, Małgorzata; Niemczyk, Kazimierz; Niderla-Bielińska, Justyna; Łukawska-Popieluch, Izabela; Grzela, Tomasz
2017-10-01
To assess the expression of endoglin in head and neck paragangliomas and the soluble endoglin level in serum of paraganglioma patients. Seven tumor samples of patients operated for cervical paraganglioma were assessed, as well as serum samples collected preoperatively, on days 4 and 28 postoperation. Serum level of endoglin in healthy controls was also determined. Tumor samples were subjected to immunofluorescent staining and examined with confocal microscope. The level of soluble endoglin in serum samples was examined using the immunoenzymatic assay (ELISA). Endoglin was highly expressed in all tumor samples. The level of soluble endoglin was significantly higher in paraganglioma patients compared to healthy controls and correlated with the tumor size. The serum level of s-endoglin was reduced after surgical excision of the tumor and remained stable after 4 weeks in all patients with complete resection of the tumor. Endoglin is an important factor in the pathophysiology of head and neck paragangliomas and may be a potential diagnostic and prognostic marker in these types of tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyle, Jennifer E.; Casey, Cameron P.; Stratton, Kelly G.
The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules weremore » identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.« less
Maki, Katsuyuki; Watabe, Etsuko; Iguchi, Yumi; Nakamura, Hideko; Tomishima, Masaki; Ohki, Hidenori; Yamada, Akira; Matsumoto, Satoru; Ikeda, Fumiaki; Tawara, Shuichi; Mutoh, Seitaro
2006-01-01
To establish an in vitro method of predicting in vivo efficacy of antifungal drugs against Candida albicans and Aspergillus fumigatus, the antifungal activities of fluconazole, itraconazole, and amphotericin B were determined in mouse serum. The minimum inhibitory concentration (MIC) of each drug was measured using mouse serum as a diluent. For C. albicans, the assay endpoint of azoles was defined as inhibition of mycelial extension (mMIC) and for A. fumigatus, as no growth (MIC). The MICs of amphotericin B for both pathogens were defined as the MIC at which no mycelial growth occurred. Serum MIC or mMIC determinations were then used to estimate the concentration of the drugs in serum of mice treated with antifungal drugs by multiplying the antifungal titer of the serum samples by the serum (m)MIC. The serum drug concentrations were also determined by HPLC. The serum concentrations estimated microbiologically showed good agreement with those determined by HPLC, except for itraconazole. Analysis of the serum samples from itraconazole-treated mice by a sensitive bioautography revealed the presence of additional spots, not seen in control samples of itraconazole. The bioautography assay demonstrated that the additional material detected in serum from mice treated with itraconazole was an active metabolite of itraconazole. The data showed that the apparent reduction in the itraconazole serum concentration as determined by HPLC was the result of the formation of an active metabolite, and that the use of a microbiological method to measure serum concentrations of drugs can provide a method for prediction of in vivo efficacy of antifungal drugs.
Gallardo-Gómez, María; Moran, Sebastian; Páez de la Cadena, María; Martínez-Zorzano, Vicenta Soledad; Rodríguez-Berrocal, Francisco Javier; Rodríguez-Girondo, Mar; Esteller, Manel; Cubiella, Joaquín; Bujanda, Luis; Castells, Antoni; Balaguer, Francesc; Jover, Rodrigo; De Chiara, Loretta
2018-01-01
Colorectal cancer is the fourth cause of cancer-related deaths worldwide, though detection at early stages associates with good prognosis. Thus, there is a clear demand for novel non-invasive tests for the early detection of colorectal cancer and premalignant advanced adenomas, to be used in population-wide screening programs. Aberrant DNA methylation detected in liquid biopsies, such as serum circulating cell-free DNA (cfDNA), is a promising source of non-invasive biomarkers. This study aimed to assess the feasibility of using cfDNA pooled samples to identify potential serum methylation biomarkers for the detection of advanced colorectal neoplasia (colorectal cancer or advanced adenomas) using microarray-based technology. cfDNA was extracted from serum samples from 20 individuals with no colorectal findings, 20 patients with advanced adenomas, and 20 patients with colorectal cancer (stages I and II). Two pooled samples were prepared for each pathological group using equal amounts of cfDNA from 10 individuals, sex-, age-, and recruitment hospital-matched. We measured the methylation levels of 866,836 CpG positions across the genome using the MethylationEPIC array. Pooled serum cfDNA methylation data meets the quality requirements. The proportion of detected CpG in all pools (> 99% with detection p value < 0.01) exceeded Illumina Infinium methylation data quality metrics of the number of sites detected. The differential methylation analysis revealed 1384 CpG sites (5% false discovery rate) with at least 10% difference in the methylation level between no colorectal findings controls and advanced neoplasia, the majority of which were hypomethylated. Unsupervised clustering showed that cfDNA methylation patterns can distinguish advanced neoplasia from healthy controls, as well as separate tumor tissue from healthy mucosa in an independent dataset. We also observed that advanced adenomas and stage I/II colorectal cancer methylation profiles, grouped as advanced neoplasia, are largely homogenous and clustered close together. This preliminary study shows the viability of microarray-based methylation biomarker discovery using pooled serum cfDNA samples as an alternative approach to tissue specimens. Our strategy sets an open door for deciphering new non-invasive biomarkers not only for colorectal cancer detection, but also for other types of cancers.
Clustering of Toxoplasma gondii Infections Within Families of Congenitally Infected Infants
Contopoulos-Ioannidis, Despina; Wheeler, Kelsey M.; Ramirez, Raymund; Press, Cindy; Mui, Ernest; Zhou, Ying; Van Tubbergen, Christine; Prasad, Sheela; Maldonado, Yvonne; Withers, Shawn; Boyer, Kenneth M.; Noble, A. Gwendolyn; Rabiah, Peter; Swisher, Charles N.; Heydemann, Peter; Wroblewski, Kristen; Karrison, Theodore; Grigg, Michael E.; Montoya, Jose G.; McLeod, Rima
2015-01-01
Background. Family clusters and epidemics of toxoplasmosis in North, Central, and South America led us to determine whether fathers of congenitally infected infants in the National Collaborative Chicago-Based Congenital Toxoplasmosis Study (NCCCTS) have a high incidence of Toxoplasma gondii infection. Methods. We analyzed serum samples collected from NCCCTS families between 1981 and 2013. Paternal serum samples were tested for T. gondii antibodies with immunoglobulin (Ig) G dye test and IgM enzyme-linked immunosorbent assay. Additional testing of paternal serum samples was performed with differential-agglutination and IgG avidity tests when T. gondii IgG and IgM results were positive and serum samples were collected by the 1-year visit of the congenitally infected child. Prevalence of paternal seropositivity and incidence of recent infection were calculated. We analyzed whether certain demographics, maternal parasite serotype, risk factors, or maternal/infant clinical manifestations were associated with paternal T. gondii infection status. Results. Serologic testing revealed a high prevalence (29 of 81; 36%) of T. gondii infection in fathers, relative to the average seropositivity rate of 9.8% for boys and men aged 12–49 years in the United States between 1994 and 2004 (P < .001). Moreover, there was a higher-than-expected incidence of recent infections among fathers with serum samples collected by the 1-year visit of their child (6 of 45; 13%; P < .001). No demographic patterns or clinical manifestations in mothers or infants were associated with paternal infections, except for sandbox exposure. Conclusions. The high prevalence of chronic and incidence of recent T. gondii infections in fathers of congenitally infected children indicates that T. gondii infections cluster within families in North America. When a recently infected person is identified, family clustering and community risk factors should be investigated for appropriate clinical management. PMID:26405150
Clustering of Toxoplasma gondii Infections Within Families of Congenitally Infected Infants.
Contopoulos-Ioannidis, Despina; Wheeler, Kelsey M; Ramirez, Raymund; Press, Cindy; Mui, Ernest; Zhou, Ying; Van Tubbergen, Christine; Prasad, Sheela; Maldonado, Yvonne; Withers, Shawn; Boyer, Kenneth M; Noble, A Gwendolyn; Rabiah, Peter; Swisher, Charles N; Heydemann, Peter; Wroblewski, Kristen; Karrison, Theodore; Grigg, Michael E; Montoya, Jose G; McLeod, Rima
2015-12-15
Family clusters and epidemics of toxoplasmosis in North, Central, and South America led us to determine whether fathers of congenitally infected infants in the National Collaborative Chicago-Based Congenital Toxoplasmosis Study (NCCCTS) have a high incidence of Toxoplasma gondii infection. We analyzed serum samples collected from NCCCTS families between 1981 and 2013. Paternal serum samples were tested for T. gondii antibodies with immunoglobulin (Ig) G dye test and IgM enzyme-linked immunosorbent assay. Additional testing of paternal serum samples was performed with differential-agglutination and IgG avidity tests when T. gondii IgG and IgM results were positive and serum samples were collected by the 1-year visit of the congenitally infected child. Prevalence of paternal seropositivity and incidence of recent infection were calculated. We analyzed whether certain demographics, maternal parasite serotype, risk factors, or maternal/infant clinical manifestations were associated with paternal T. gondii infection status. Serologic testing revealed a high prevalence (29 of 81; 36%) of T. gondii infection in fathers, relative to the average seropositivity rate of 9.8% for boys and men aged 12-49 years in the United States between 1994 and 2004 (P < .001). Moreover, there was a higher-than-expected incidence of recent infections among fathers with serum samples collected by the 1-year visit of their child (6 of 45; 13%; P < .001). No demographic patterns or clinical manifestations in mothers or infants were associated with paternal infections, except for sandbox exposure. The high prevalence of chronic and incidence of recent T. gondii infections in fathers of congenitally infected children indicates that T. gondii infections cluster within families in North America. When a recently infected person is identified, family clustering and community risk factors should be investigated for appropriate clinical management. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Huang, Jing-Tao; Yang, Ying; Hu, Yi-Min; Liu, Xing-Hui; Liao, Mei-Yan; Morgan, Roy; Yuan, Er-Feng; Li, Xia; Liu, Song-Mei
2018-05-01
Despite implications of persistence of hepatitis B virus (HBV) covalently closed circular DNA (cccDNA) in the development of hepatocellular carcinoma (HCC), little is known about serum cccDNA in HBV-infected diseases. We developed a cccDNA-selective droplet digital PCR (ddPCR) to assess cccDNA content and dynamics across different stages of HCC development. One hundred forty-seven serum samples and 35 formalin-fixed, paraffin-embedded tumor tissues were derived from patients with HCC or HBV hepatitis/cirrhosis. After specific amplification and selective digestion, probe-based ddPCR was used to quantify cccDNA copy numbers in single cells and clinical samples. The cccDNA in single HepG2.2.15 cells ranged from 0 to 10.8 copies/cell. Compared with non-HCC patients, HCC patients showed a higher cccDNA-positive rate (89.9% versus 53.2%; P = 4.22 × 10 -6 ) and increased serum cccDNA contents (P = 0.002 and P = 0.041 for hepatitis and cirrhosis patients, respectively). Serum cccDNA ranged from 84 to 1.07 × 10 5 copies/mL. Quantification of serum cccDNA and HBV-DNA was an effective way to discriminate HCC patients from non-HCC patients, with areas under the curve of receiver operating characteristic of 0.847 (95% CI, 0.759-0.935; sensitivity, 74.5%; specificity, 93.7%). cccDNA-selective ddPCR is sensitive to detect cccDNA in single cells and different clinical samples. Combined analysis of serum cccDNA and HBV-DNA may be a promising strategy for HBV-induced HCC surveillance and antiviral therapy evaluation. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Davies, R H; Heath, P J; Coxon, S M; Sayers, A R
2003-01-01
Monitoring for Salmonella in slaughter pigs is important to enable targeted control measures to be applied on problem farms and at the abattoir. The aim of this study was to determine whether pooled serum and meat juice could be used to identify finishing pig herds with a high prevalence of infection. Samples of meat juice, serum, caecal contents, carcase swabs and pooled faeces from pig pens were taken from 20 commercial pig finishing farms and comparisons were made between the results of Salmonella culture, individual ELISA tests on serum and meat juice and pooled samples of serum and meat juice. Salmonella was isolated from samples from 19 of 20 farms. None of the ELISA tests showed a statistically significant correlation with caecal carriage of Salmonella or contamination of carcases. Serum mean optical density (O.D.) from pools of five, 10 or 20 sera showed a significant correlation with the Salmonella status of farm pen faeces. All pooled serum O.D. and sample/positive control ratio results correlated significantly with the results of the conventional individual sample ELISA. There was a statistically significant correlation between the incidence of Salmonella in farm pen pooled faeces and the prevalence of Salmonella in caeca of slaughter pigs. The results show a generally poor correlation between serological and bacteriological results but pooled serum or meat juice samples could be used as a cheaper substitute for serological screening of farms for Salmonella than individual samples. The availability of a cheaper test should allow the costs of Salmonella monitoring of pig farms to be reduced or allow more regular testing to enhance the designation of farm Salmonella risk status.
Kulkarni, Diwakar D; Venkatesh, Govindarajalu; Tosh, Chakradhar; Patel, Priyanka; Mashoria, Anita; Gupta, Vandana; Gupta, Sourabh; D, Senthilkumar
2016-01-01
The recombinant viral protein-based indirect enzyme-linked immunosorbent assay (ELISA) is a cost-effective, safe, specific, and rapid tool to diagnose the viral infection. Nipah virus nucleocapsid (NiV-N) protein was expressed in Escherichia coli and purified by histidine tag-based affinity chromatography. The N protein was selected based on its immuno dominance and conservation among different NiV strains. An indirect immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for swine sera was optimized using the recombinant NiV-N protein as an antigen along with negative and positive controls. The background reading was blocked using skim milk powder and chicken serum. A total number of 1709 swine serum samples from various states of India were tested with indirect ELISA and Western blot. The test was considered positive only when its total reactivity reading was higher than 0.2 cut-off value and the ratio of the total reactivity to the background reading was more than 2.0. Since specificity is high for Western blotting it was used as standard test for comparison of results of indirect ELISA. Sensitivity and specificity of indirect ELISA was 100% and 98.7%, respectively, in comparison with Western blotting. Recombinant N protein-based ELISA can be used in screening large number of serum samples for epidemiological investigations in developing countries where high containment laboratories are not available to handle this zoonotic virus.
Detection of Serum microRNAs From Department of Defense Serum Repository
Woeller, Collynn F.; Thatcher, Thomas H.; Van Twisk, Daniel; Pollock, Stephen J.; Croasdell, Amanda; Kim, Nina; Hopke, Philip K.; Xia, Xiaoyan; Thakar, Juilee; Mallon, COL Timothy M.; Utell, Mark J.; Phipps, Richard P.
2017-01-01
Objective The aim of this study was to investigate whether serum samples from the Department of Defense Serum Repository (DoDSR) are of sufficient quality to detect microRNAs (miRNAs), cytokines, immunoglobulin E (IgE), and polycyclic aromatic hydrocarbons (PAHs). Methods MiRNAs were isolated and quantified by polymerase chain reaction (PCR) array. Cytokines and chemokines related to inflammation were measured using multiplex immunoassays. Cotinine and IgE were detected by enzyme-linked immunoassay (ELISA) and PAHs were detected by Liquid Chromatography/Mass Spectroscopy. Results We detected miRNAs, cytokines, IgE, and PAHs with high sensitivity. Eleven of 30 samples tested positive for cotinine suggesting tobacco exposure. Significant associations between serum cotinine, cytokine, IgE, PAHs, and miRNA were discovered. Conclusion We successfully quantified over 200 potential biomarkers of occupational exposure from DoDSR samples. The stored serum samples were not affected by hemolysis and represent a powerful tool for biomarker discovery and analysis in retrospective studies. PMID:27501106
Xu, Hui; Wang, Shuyu
2012-04-29
In this study, a porous polypropylene frit was coated with polydimethylsiloxane (PDMS) as extraction medium, based on the home-made PDMS-frit, a rapid, simple and sensitive sorptive extraction method was established for analysis of potential biomarkers of lung cancer (hexanal and heptanal) in human serum samples. In the method, derivatization and extraction occurred simultaneously on the PDMS-frit, then the loaded frit was ultrasonically desorbed in acetonitrile. Polymerization, derivatization-extraction and desorption conditions were optimized. Under the optimal conditions, satisfactory results were gained, a wide linear application range was obtained in the range of 0.002-5.0 μmol L(-1) (R>0.997) for two aldehydes, the detection limits (SN(-1)=3) were 0.5 nmol L(-1) for hexanal and 0.4 nmol L(-1) for heptanal. The relative standard deviations (RSDs, n=5) of the method were below 7.9% and the recoveries were above 72.7% for the spiked serum. All these results hint that the proposed method is potential for disease markers analysis in complex biological samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Chen, Yan-Ni; Du, Hui-Ying; Shi, Zhuo-Yue; He, Li; He, Yu-Ying; Wang, Duan
2018-01-24
The pathogenesis of autism spectrum disorders remains elusive and currently there are no diagnostic or predictive biomarkers in autism available. Proteomic profiling has been used in a wide range of neurodevelopmental disorder studies, which could produce deeper perceptions of the molecular bases behind certain disease and potentially becomes useful in discovering biomarkers in autism spectrum disorders. Serum samples were collected from autistic children about 3 years old in age (n = 32) and healthy controls (n = 20) in similar age and gender. The samples were identified specific proteins that are differentially expressed by magnetic bead-based pre-fractionation and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-ToF-MS). Eight protein peaks were significantly different in autistic children from the healthy controls (P < 0.0001). The two peaks with the most significant differences were 6428 and 7758 Da in size. According to differences in serum protein profiles between the autistic children and healthy controls, this study identified a set of differentially expressed proteins those are significant for further evaluation and might function as biomarkers in autism.
Wang, Jiasheng; Hui, Ni
2018-06-16
A non-fouling electrochemical immunosensor is described for determination of the tumor biomarker carcinoembryonic antigen (CEA). It is based on the use of composite wires made by chemical grafting of hyaluronic acid onto polyaniline nanowires. The modified nanowires possess excellent antifouling property both in single protein solutions and in dilute serum samples. The current of immunoelectrode exhibits a linear response in the 0.01 pg mL -1 to 10,000 pg mL -1 CEA concentration range and 0.0075 pg mL -1 detection limit. This work demonstrates that coating an electrode with hyaluronic acid can largely reduce unspecific adsorption of proteins on the electrode surface. Graphical abstract Schematic of a nonfouling electrochemical immunosensor for the carcinoembryonic antigen. It is based on novel composite wires made through the chemical grafting of easily available hyaluronic acid (HA) onto polyaniline (PANI) nanowires. The HA/PANI demonstrated excellent antifouling property both in single protein solutions and human serum samples.
NASA Astrophysics Data System (ADS)
Rocha-Osornio, L. N.; Pichardo-Molina, J. L.; Barbosa-Garcia, O.; Frausto-Reyes, C.; Araujo-Andrade, C.; Huerta-Franco, R.; Gutiérrez-Juárez, G.
2008-02-01
Raman spectroscopy and Multivariate methods were used to study serum blood samples of control and breast cancer patients. Blood samples were obtained from 11 patients and 12 controls from the central region of Mexico. Our results show that principal component analysis is able to discriminate serum sample of breast cancer patients from those of control group, also the loading vectors of PCA plotted as a function of Raman shift shown which bands permitted to make the maximum discrimination between both groups of samples.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study.
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Vazquez-Rosales, Guillermo; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Cevallos, Ana Maria; Xoconostle-Cazares, Beatriz; Lira, Rosalia
2017-01-01
Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µ l of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µ l. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Xoconostle-Cazares, Beatriz
2017-01-01
Background Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Methods Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion DSS samples are useful for detecting anti-dengue IgG antibodies in the field. PMID:28630868
Investigation of Metabolomic Blood Biomarkers for Detection of Adenocarcinoma Lung Cancer
Fahrmann, Johannes F.; Kim, Kyoungmi; DeFelice, Brian C.; Taylor, Sandra L.; Gandara, David R.; Yoneda, Ken Y.; Cooke, David T.; Fiehn, Oliver; Kelly, Karen; Miyamoto, Suzanne
2015-01-01
Background Untargeted metabolomics was utilized in case control studies of adenocarcinoma (ADC) lung cancer in order to develop and test metabolite classifiers in serum and plasma as potential biomarkers for diagnosing lung cancer. Methods Serum and plasma were collected and used in two independent case-control studies (ADC1 and ADC2). Controls were frequency matched for gender, age and smoking history. There were 52 ADC cases and 31 controls in ADC1 and 43 ADC cases and 43 controls in ADC2. Metabolomics was conducted using gas chromatography time-of-flight mass spectrometry. Differential analysis was performed on ADC1 and the top candidates (FDR < 0.05) for serum and plasma used to develop individual and multiplex-classifiers that were then tested on an independent set of serum and plasma samples (ADC2). Results Aspartate provided the best accuracy (81.4%) for an individual metabolite classifier in serum whereas pyrophosphate had the best accuracy (77.9%) in plasma when independently tested. Multiplex classifiers of either 2 or 4 serum metabolites had an accuracy of 72.7% when independently tested. For plasma, a multi-metabolite classifier consisting of 8 metabolites gave an accuracy of 77.3% when independently tested. Comparison of overall diagnostic performance between the two blood matrices yielded similar performances. However, serum is most ideal given higher sensitivity for low abundant metabolites. Conclusion This study shows the potential of metabolite-based diagnostic tests for detection of lung adenocarcinoma. Further validation in a larger pool of samples is warranted. Impact These biomarkers could improve early detection and diagnosis of lung cancer. PMID:26282632
Identification of a sulfate metabolite of PCB 11 in human serum
Grimm, Fabian A.; Lehmler, Hans-Joachim; Koh, Wen Xin; DeWall, Jeanne; Teesch, Lynn M.; Hornbuckle, Keri C.; Thorne, Peter S.; Robertson, Larry W.; Duffel, Michael W.
2016-01-01
Despite increasing evidence for a major role for sulfation in the metabolism of lower-chlorinated polychlorinated biphenyls in vitro and in vivo, and initial evidence for potential bioactivities of the resulting sulfate ester metabolites, the formation of PCB sulfates in PCB exposed human populations had not been explored. The primary goal of this study was to determine if PCB sulfates, and potentially other conjugated PCB derivatives, are relevant classes of PCB metabolites in the serum of humans with known exposures to PCBs. In order to detect and quantify dichlorinated PCB sulfates in serum samples of 46 PCB-exposed individuals from either rural or urban communities, we developed a high-resolution mass spectrometry-based protocol using 4-PCB 11 sulfate as a model compound. The method also allowed the preliminary analysis of these 46 human serum extracts for the presence of other metabolites, such as glucuronic acid conjugates and hydroxylated PCBs. Sulfate ester metabolites derived from dichlorinated PCBs were detectable and quantifiable in more than 20 % of analyzed serum samples. Moreover, we were able to utilize this method to detect PCB glucuronides and hydroxylated PCBs, albeit at lower frequencies than PCB sulfates. Altogether, our results provide initial evidence for the presence of PCB sulfates in human serum. Considering the inability of previously employed analytical protocols for PCBs to extract these sulfate ester metabolites and the concentrations of these metabolites observed in our current study, our data support the hypothesis that total serum levels of PCB metabolites in exposed individuals may have been underestimated in the past. PMID:27816204
Identification of a sulfate metabolite of PCB 11 in human serum.
Grimm, Fabian A; Lehmler, Hans-Joachim; Koh, Wen Xin; DeWall, Jeanne; Teesch, Lynn M; Hornbuckle, Keri C; Thorne, Peter S; Robertson, Larry W; Duffel, Michael W
2017-01-01
Despite increasing evidence for a major role for sulfation in the metabolism of lower-chlorinated polychlorinated biphenyls in vitro and in vivo, and initial evidence for potential bioactivities of the resulting sulfate ester metabolites, the formation of PCB sulfates in PCB exposed human populations had not been explored. The primary goal of this study was to determine if PCB sulfates, and potentially other conjugated PCB derivatives, are relevant classes of PCB metabolites in the serum of humans with known exposures to PCBs. In order to detect and quantify dichlorinated PCB sulfates in serum samples of 46 PCB-exposed individuals from either rural or urban communities, we developed a high-resolution mass spectrometry-based protocol using 4-PCB 11 sulfate as a model compound. The method also allowed the preliminary analysis of these 46 human serum extracts for the presence of other metabolites, such as glucuronic acid conjugates and hydroxylated PCBs. Sulfate ester metabolites derived from dichlorinated PCBs were detectable and quantifiable in more than 20% of analyzed serum samples. Moreover, we were able to utilize this method to detect PCB glucuronides and hydroxylated PCBs, albeit at lower frequencies than PCB sulfates. Altogether, our results provide initial evidence for the presence of PCB sulfates in human serum. Considering the inability of previously employed analytical protocols for PCBs to extract these sulfate ester metabolites and the concentrations of these metabolites observed in our current study, our data support the hypothesis that total serum levels of PCB metabolites in exposed individuals may have been underestimated in the past. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava
2015-01-01
We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.
Protein Turnover Measurements in Human Serum by Serial Immunoaffinity LC-MS/MS.
Farrokhi, Vahid; Chen, Xiaoying; Neubert, Hendrik
2018-02-01
The half-life of target proteins is frequently an important parameter in mechanistic pharmacokinetic and pharmacodynamic (PK/PD) modeling of biotherapeutics. Clinical studies for accurate measurement of physiologically relevant protein turnover can reduce the uncertainty in PK/PD model-based predictions, for example, of the therapeutic dose and dosing regimen in first-in-human clinical trials. We used a targeted mass spectrometry work flow based on serial immunoaffinity enrichment ofmultiple human serum proteins from a [5,5,5- 2 H 3 ]-L-leucine tracer pulse-chase study in healthy volunteers. To confirm the reproducibility of turnover measurements from serial immunoaffinity enrichment, multiple aliquots from the same sample set were subjected to protein turnover analysis in varying order. Tracer incorporation was measured by multiple-reaction-monitoring mass spectrometry and target turnover was calculated using a four-compartment pharmacokinetic model. Five proteins of clinical or therapeutic relevance including soluble tumor necrosis factor receptor superfamily member 12A, tissue factor pathway inhibitor, soluble interleukin 1 receptor like 1, soluble mucosal addressin cell adhesion molecule 1, and muscle-specific creatine kinase were sequentially subjected to turnover analysis from the same human serum sample. Calculated half-lives ranged from 5-15 h; however, no tracer incorporation was observed for mucosal addressin cell adhesion molecule 1. The utility of clinical pulse-chase studies to investigate protein turnover can be extended by serial immunoaffinity enrichment of target proteins. Turnover analysis from serum and subsequently from remaining supernatants provided analytical sensitivity and reproducibility for multiple human target proteins in the same sample set, irrespective of the order of analysis. © 2017 American Association for Clinical Chemistry.
NASA Astrophysics Data System (ADS)
Farnoudian-Habibi, Amir; Massoumi, Bakhshali; Jaymand, Mehdi
2016-11-01
A novel and efficient strategy for the simultaneous determination of two tricyclic antidepressant (TCA) drugs [amitriptyline (AT), and its main metabolite (nortriptyline; NT)] via a combination of magnetic solid phase extraction (MSPE), and spectrophotometric techniques in serum is suggested. For this purpose, the imidazolium ionic liquid (Imz)-modified Fe3O4@SiO2 nanoparticles (Fe3O4@SiO2-Imz) was employed as an adsorbent for the MSPE. Preconcentration (loading-desorption) studies were performed under optimized conditions including pH, adsorbent amount, contact time, eluent volume, and desorption time. Afterward, determination of each drug was carried out by specific strategy. Acetaldehyde (AC), and 2,3,5,6-tetrachloro-1,4-benzoquinone (chloranil; CL) were used as chemical reagents for reaction with NT, while AT did not react with these reagents. This method is based on the condensation reaction between secondary amine group of NT and AC to afford an enamine, and subsequently reaction with CL to produce a chlorinated quinone-substituted enamine. The final product exhibited maximum absorption at 556 nm, while the AT was determined at 240 nm. The limits of detections (LODs) for NT and AT in serum sample were obtained as 0.19 and 0.90 ng mL- 1, respectively. The limits of quantifications (LOQs) were obtained to be 0.63 and 2.93 ng mL- 1 for NT and AT, respectively. A linear range was obtained to be 1 to 5 ng mL- 1. Results indicated that the suggested method is applicable for simultaneous determination of NT and AT in serum samples.
Jensen, Berit P; Saraf, Rajneeta; Ma, Jing; Berry, Sarah; Grant, Cameron C; Camargo, Carlos A; Sies, Christiaan W
2018-06-01
Demand for measurement of 25-hydroxyvitamin D (25OHD) is growing and dried blood spot (DBS) sampling is attractive as samples are easier to collect, transport and store. A 2D LC-MS/MS assay without derivatization was developed. DBS punches (3.2 mm) were ultrasonicated with d 6 -25OHD 3 in 70% methanol followed by hexane extraction, dry-down and reconstitution. The assay was validated and applied to two studies comparing whole blood adult DBS with serum samples (n = 40) and neonatal whole blood DBS with cord serum samples (n = 80). The assay was validated in whole blood DBS over the range 13-106 nmol/L 25OHD 3 and 11-91 nmol/L 25OHD 2 with a limit of detection of 3 nmol/L. Intra- and inter-day imprecision was <13% CV and bias <12%. The assay had high recovery and minimal matrix effects. Triplicate DBS study samples had a mean CV of ≤13% for 25OHD 3. No 25OHD 2 was detected. DBS calculated serum 25OHD 3 concentrations correlated strongly with serum concentrations in the adult DBS/serum study (r = 0.94) and moderately in the neonatal DBS/cord serum study (r = 0.69). Direct quantitation of 25OHD in DBS by 2D LC-MS/MS without derivatization was found to be an alternative to serum quantitation applicable to clinical research studies on adult DBS samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Clark, R G; Ellison, R S; Mortleman, L; Kirk, J A; Henderson, H V
1999-08-01
To obtain information on serum and liver vitamin B12 and urinary methylmalonic acid concentrations as diagnostic tests to predict a weight gain response to supplementation with vitamin B12 in young dairy cattle when grazing pasture of low cobalt content. Methodology. Forty dairy cattle (12 Friesian, 14 Friesian x Jersey and 14 Jersey) were allocated to two equal sized groups, treated and untreated, based on liveweight. At monthly intervals for 14 months, all animals were weighed, their serum and urine sampled, their liver biopsied and the pasture sampled from the paddocks they were grazing and going to graze. Serum and liver were assayed for vitamin B12 concentrations. For the first 5 months of the trial, urine was assayed for methylmalonic acid concentrations. Both washed and unwashed pasture samples were assayed for cobalt concentrations. No weight gain response occurred vitamin B12 supplementation in young growing cattle grazing pasture with a cobalt concentration of 0.04-0.06 mg/kg DM. For 5 months of the trial, liver vitamin B12 concentrations from untreated calves were in the range 75-220 nmol/kg and serum vitamin B12 concentrations were as low as 72 pmol/1. There was no associated growth response to supplementation. Further trials involving young cattle grazing pastures with cobalt concentrations less than 0.04 mg/kg DM are required to reliably determine liver and serum vitamin B12 concentrations at which growth responses to vitamin B12 or cobalt supplementation are likely under New Zealand pastoral grazing conditions.
Vijaylakshmi, P; Muthukkaruppan, V R; Rajasundari, A; Korukluoglu, G; Nigatu, W; L A Warrener; Samuel, D; Brown, D W G
2006-12-01
Clinical diagnosis (surveillance) of rubella is unreliable and laboratory confirmation is essential. Detection of virus specific IgM in serum is the most commonly used method. However, the use of serum necessitates the drawing of blood, either through venipuncture or finger/heel prick, which can be difficult in young babies. Oral fluid samples have proved useful as an alternative, less invasive sample for virus specific IgM detection however until recently no commercial rubella IgM tests were available, restricting the usefulness of this approach. To evaluate the performance of the Microimmune Rubella IgM capture EIA using oral fluid samples from outbreaks as well as in cases of suspected congenital rubella syndrome (CRS). Paired serum and oral fluids were collected from cases during a rubella outbreak in three provinces in Turkey. Matched serum and oral fluid samples were collected from children with suspected CRS in an active surveillance programme at the Aravind Eye Hospital in South India. Serum samples were collected as part of the measles surveillance programme in Ethiopia. On serum samples the sensitivity and specificity of the Microimmune Rubella IgM capture EIA compared to Behring Enzygnost rubella IgM test was 96.9% (62/64; 95% CI 94.2-100%) and 100% (53/53; 95% CI 93.2-100%). On oral fluids compared to matched Behring results on serum the sensitivity was 95.5% (42/44; 95% CI 84.5-99.4%). The sensitivity and specificity of Microimmune Rubella IgM capture EIA on oral fluids from suspected CRS cases compared to serum results using Behring Enzygnost IgM assay was 100% (95% CI 84.5-100%) and 100% (95% CI 95.8-100.0%) respectively. Microimmune Rubella IgM capture EIA has adequate performance for diagnosis and surveillance of rubella in outbreak using either serum or oral fluid specimens.
Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils
2014-01-01
Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.
Kikkas, Ingrid; Mallone, Roberto; Larger, Etienne; Volland, Hervé; Morel, Nathalie
2014-01-01
Type 1 diabetes (T1D) results from the destruction of pancreatic insulin-producing beta cells and is strongly associated with the presence of islet autoantibodies. Autoantibodies to tyrosine phosphatase-like protein IA-2 (IA-2As) are considered to be highly predictive markers of T1D. We developed a novel lateral flow immunoassay (LFIA) based on a bridging format for the rapid detection of IA-2As in human serum samples. In this assay, one site of the IA-2As is bound to HA-tagged-IA-2, which is subsequently captured on the anti-HA-Tag antibody-coated test line on the strip. The other site of the IA-2As is bound to biotinylated IA-2, allowing the complex to be visualized using colloidal gold nanoparticle-conjugated streptavidin. For this study, 35 serum samples from T1D patients and 44 control sera from non-diabetic individuals were analyzed with our novel assay and the results were correlated with two IA-2A ELISAs. Among the 35 serum samples from T1D patients, the IA-2A LFIA, the in-house IA-2A ELISA and the commercial IA-2A ELISA identified as positive 21, 29 and 30 IA-2A-positive sera, respectively. The major advantages of the IA-2A LFIA are its rapidity and simplicity.
Sung, Hye-Jin; Jeon, Seon-Ae; Ahn, Jung-Mo; Seul, Kyung-Jo; Kim, Jin Young; Lee, Ju Yeon; Yoo, Jong Shin; Lee, Soo-Youn; Kim, Hojoong; Cho, Je-Yoel
2012-04-03
Quantification is an essential step in biomarker development. Multiple reaction monitoring (MRM) is a new modified mass spectrometry-based quantification technology that does not require antibody development. Serum amyloid A (SAA) is a positive acute-phase protein identified as a lung cancer biomarker in our previous study. Acute SAA exists in two isoforms with highly similar (92%) amino acid sequences. Until now, studies of SAA have been unable to distinguish between SAA1 and SAA2. To overcome the unavailability of a SAA2-specific antibody, we developed MRM methodology for the verification of SAA1 and SAA2 in clinical crude serum samples from 99 healthy controls and 100 lung adenocarcinoma patients. Differential measurement of SAA1 and SAA2 was made possible for the first time with the developed isotype-specific MRM method. Most healthy control samples had small or no MS/MS peaks of the targeted peptides otherwise, higher peak areas with 10- to 34-fold increase over controls were detected in lung cancer samples. In addition, our SAA1 MRM data demonstrated good agreement with the SAA1 enzyme-linked immunosorbent assay (ELISA) data. Finally, successful quantification of SAA2 in crude serum by MRM, for the first time, shows that SAA2 can be a good biomarker for the detection of lung cancers. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Arain, Salma Aslam; Kazi, Tasneem G.; Afridi, Hassan Imran; Abbasi, Abdul Rasool; Panhwar, Abdul Haleem; Naeemullah; Shanker, Bhawani; Arain, Mohammad Balal
2014-12-01
An efficient, innovative preconcentration method, dual-cloud point extraction (d-CPE) has been developed for the extraction and preconcentration of copper (Cu2+) in serum samples of different viral hepatitis patients prior to couple with flame atomic absorption spectrometry (FAAS). The d-CPE procedure was based on forming complexes of elemental ions with complexing reagent 1-(2-pyridylazo)-2-naphthol (PAN), and subsequent entrapping the complexes in nonionic surfactant (Triton X-114). Then the surfactant rich phase containing the metal complexes was treated with aqueous nitric acid solution, and metal ions were back extracted into the aqueous phase, as second cloud point extraction stage, and finally determined by flame atomic absorption spectrometry using conventional nebulization. The multivariate strategy was applied to estimate the optimum values of experimental variables for the recovery of Cu2+ using d-CPE. In optimum experimental conditions, the limit of detection and the enrichment factor were 0.046 μg L-1 and 78, respectively. The validity and accuracy of proposed method were checked by analysis of Cu2+ in certified sample of serum (CRM) by d-CPE and conventional CPE procedure on same CRM. The proposed method was successfully applied to the determination of Cu2+ in serum samples of different viral hepatitis patients and healthy controls.
Lindström, Mikael; Tohmola, Niina; Renkonen, Risto; Hämäläinen, Esa; Schalin-Jäntti, Camilla; Itkonen, Outi
2018-07-01
Serotonin (5-hydroxytyramine) is a mediator of gastrointestinal smooth muscle contraction, and is secreted by neuroendocrine neoplasms (NENs). We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum serotonin to be used in NEN diagnostics and follow-up. We used serum samples from healthy volunteers (n = 31) and patients suspected or monitored for NEN (n = 98). Serotonin-D 4 internal standard was added to samples before solid phase extraction (SPE) and quantification by LC-MS/MS. The effects of sample handling and preparation on serotonin stability were studied. Finally, we established a provisional reference range for serum serotonin and compared our assay with serum 5-hydroxyindoleacetic acid (5-HIAA) for detection of NENs. Our assay is sensitive and has a wide linear range (10-10,000 nmol/l). Serum serotonin is stable for 7 days at room temperature and for 3 months at -20 °C. Sampling temperature is not critical. Normal range for serum serotonin was 270-1490 nmol/l. We found that serum serotonin and 5-HIAA performed equally well as diagnostic tests for NENs. Our LC-MS/MS assay for serum serotonin is well suited for clinical research and patient diagnostics. Our results confirm that it can complement 5-HIAA in diagnosis of NENs. Copyright © 2018 Elsevier B.V. All rights reserved.
Wu, Yunqing; Zeng, Lifeng; Xiong, Ying; Leng, Yuankui; Wang, Hui; Xiong, Yonghua
2018-05-01
Herein, we present a novel sandwich fluorescence enzyme linked immunosorbent assay (ELISA) for highly sensitive detection of Hepatitis B virus surface antigen (HBsAg) based on glucose oxidase (GOx)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (MPA-QDs). In this system, hydrogen peroxide (H 2 O 2 ) sensitive MPA-QDs was used as a signal output, and glucose oxidase (GOx) was used as label which can generate H 2 O 2 via catalytic oxidation of glucose. The proposed method showed dynamic linear detection of HBsAg both in the range of 47pgmL -1 ~ 380pgmL -1 and 0.75ngmL -1 ~ 12.12ngmL -1 . The detection limit of the proposed fluorescence ELISA was 1.16pgmL -1 , which was approximately 430-fold lower than that of horseradish peroxidase (HRP)-based conventional ELISA. The average recoveries for HBsAg-spiked serum samples ranged from 98.0% to 126.8% with the relative standard derivation below 10%, thus indicating acceptable precision and high reproducibility of the proposed fluorescence ELISA for HBsAg detection. Additionally, the developed method showed no false positive results analyzing 35 real HBsAg-negative serum samples, and exhibited excellent agreement (R 2 =0.9907) with a commercial time-resolved fluorescence immunoassay (TRFIA) kit for detecting 31 HBsAg-positive serum samples. In summary, the proposed method based on fluorescence quenching of H 2 O 2 sensitive QDs is considerably to be an excellent biodetection platform with ultrahigh sensitivity, good accuracy and excellent reliability. Copyright © 2018 Elsevier B.V. All rights reserved.
Gautam, Aarti; Kumar, Raina; Dimitrov, George; Hoke, Allison; Hammamieh, Rasha; Jett, Marti
2016-10-01
miRNAs act as important regulators of gene expression by promoting mRNA degradation or by attenuating protein translation. Since miRNAs are stably expressed in bodily fluids, there is growing interest in profiling these miRNAs, as it is minimally invasive and cost-effective as a diagnostic matrix. A technical hurdle in studying miRNA dynamics is the ability to reliably extract miRNA as small sample volumes and low RNA abundance create challenges for extraction and downstream applications. The purpose of this study was to develop a pipeline for the recovery of miRNA using small volumes of archived serum samples. The RNA was extracted employing several widely utilized RNA isolation kits/methods with and without addition of a carrier. The small RNA library preparation was carried out using Illumina TruSeq small RNA kit and sequencing was carried out using Illumina platform. A fraction of five microliters of total RNA was used for library preparation as quantification is below the detection limit. We were able to profile miRNA levels in serum from all the methods tested. We found out that addition of nucleic acid based carrier molecules had higher numbers of processed reads but it did not enhance the mapping of any miRBase annotated sequences. However, some of the extraction procedures offer certain advantages: RNA extracted by TRIzol seemed to align to the miRBase best; extractions using TRIzol with carrier yielded higher miRNA-to-small RNA ratios. Nuclease free glycogen can be carrier of choice for miRNA sequencing. Our findings illustrate that miRNA extraction and quantification is influenced by the choice of methodologies. Addition of nucleic acid- based carrier molecules during extraction procedure is not a good choice when assaying miRNA using sequencing. The careful selection of an extraction method permits the archived serum samples to become valuable resources for high-throughput applications.
Chow, Brian A; Hamilton, Jason; Cattet, Marc R L; Stenhouse, Gordon; Obbard, Martyn E; Vijayan, Mathilakath M
2011-01-01
Polar bears (Ursus maritimus) from several subpopulations undergo extended fasting during the ice-free season. However, the animals appear to conserve protein despite the prolonged fasting, though the mechanisms involved are poorly understood. We hypothesized that elevated concentrations of corticosteroid binding globulin (CBG), the primary cortisol binding protein in circulation, lead to cortisol resistance and provide a mechanism for protein conservation during extended fasting. The metabolic state (feeding vs. fasting) of 16 field sampled male polar bears was determined based on their serum urea to creatinine ratio (>25 for feeding vs. <5 for fasting). There were no significant differences in serum cortisol levels between all male and female polar bears sampled. Serum CBG expression was greater in lactating females relative to non-lactating females and males. CBG expression was significantly higher in fasting males when compared to non-fasting males. This leads us to suggest that CBG expression may serve as a mechanism to conserve protein during extended fasting in polar bears by reducing systemic free cortisol concentrations. This was further supported by a lower serum glucose concentration in the fasting bears. As well, a lack of an enhanced adrenocortical response to acute capture stress supports our hypothesis that chronic hunger is not a stressor in this species. Overall, our results suggest that elevated serum CBG expression may be an important adaptation to spare proteins by limiting cortisol bioavailability during extended fasting in polar bears. Copyright © 2010 Elsevier Inc. All rights reserved.
López-Bascón, María Asunción; Calderón-Santiago, Mónica; Priego-Capote, Feliciano
2016-11-02
A novel class of endogenous mammalian lipids endowed with antidiabetic and anti-inflammatory properties has been recently discovered. These are fatty acid esters of hydroxy fatty acids (FAHFAs) formed by condensation between a hydroxy fatty acid and a fatty acid. FAHFAs are present in human serum and tissues at low nanomolar concentrations. Therefore, high sensitivity and selectivity profiling analysis of these compounds in clinical samples is demanded. An automated qualitative and quantitative method based on on-line coupling between solid phase extraction and liquid chromatography-tandem mass spectrometry has been here developed for determination of FAHFAs in serum with the required sensitivity and selectivity. Matrix effects were evaluated by preparation of calibration models in serum and methanol. Recovery factors ranged between 73.8 and 100% in serum. The within-day variability ranged from 7.1 to 13.8%, and the between-days variability varied from 9.3 to 21.6%, which are quite acceptable values taking into account the low concentration levels at which the target analytes are found. The method has been applied to a cohort of human serum samples to estimate the concentrations profiles as a function of the glycaemic state and obesity. Statistical analysis revealed three FAHFAs with levels significantly different depending on the glycaemic state or the body mass index. This automated method could be implemented in high-throughput analysis with minimum user assistance. Copyright © 2016 Elsevier B.V. All rights reserved.
Beppu, Minako; Sawai, Setsu; Misawa, Sonoko; Sogawa, Kazuyuki; Mori, Masahiro; Ishige, Takayuki; Satoh, Mamoru; Nomura, Fumio; Kuwabara, Satoshi
2015-02-15
To identify serum cytokine networks specific to chronic inflammatory demyelinating polyneuropathy (CIDP), serum samples of two subgroups (18 patients with typical CIDP and 12 patients with multifocal acquired demyelinating sensory and motor neuropathy [MADSAM]) were analyzed with multiplex magnetic bead-based cytokine assay. TNF-α, HGF, MIP-1β and IL-1β levels were significantly higher in total CIDP patients than in normal controls. Of these, HGF levels were elevated in typical CIDP patients, but not in MADSAM patients. Patients with high HGF levels showed good responses to steroid treatment. Different cytokine profiles among the CIDP subtypes presumably reflect differences in pathophysiology. Copyright © 2014 Elsevier B.V. All rights reserved.
Szabó, I; Scherer, K; Roesler, U; Appel, B; Nöckler, K; Hensel, A
2008-05-10
The most frequently isolated Salmonella serotype from pork in Germany is S. typhimurium, especially phagetype DT 104. The monitoring programs on Salmonella in swine are based on enzyme-linked immunoadsorbent assay (ELISA) detecting antibodies in serum or meat juice. These serological results are used to classify swine herds in three categories to assess the hygienic status of farm regarding Salmonella infection in pigs. The object of this study was the comparative evaluation of four indirect Salmonella ELISA tests approved in Germany to detect Salmonella typhimurium infection of swine. Three tests (A-C) are based on LPS-antigen and directed against specific IgG-antibodies. The fourth test (D) bases on a whole-cell-lysate antigen and discriminates between Salmonella specific IgA-, IgM- and IgG-antibodies. In a longitudinal study sixteen 6 weeks old weaning pigs were orally infected with S. typhimurium DT 104. During an observation period of 138d clinical and bacteriological parameters were monitored and serum samples obtained at regular intervals as well as meat juice samples taken at slaughter were examined by the respective ELISA systems. Study results reveal that all tested ELISA systems are able to detect S. typhimurium infection in pigs in both sample matrices, blood serum and meat juice whereas test D showed the highest sensitivity to detect Salmonella antibodies in pigs. The sensitivity to detect Salmonella antibodies varied between tests A and C according to the used cut-off (test specific cut-off vs. recommended surveillance cut-off) resulting in a change of seroprevalence and hence may influence the Salmonella status of the farm.
Low-cost and reagent-free paper-based device to detect chloride ions in serum and sweat.
Cinti, Stefano; Fiore, Luca; Massoud, Renato; Cortese, Claudio; Moscone, Danila; Palleschi, Giuseppe; Arduini, Fabiana
2018-03-01
The recent goal of sustainability in analytical chemistry has boosted the development of eco-designed analytical tools to deliver fast and cost-effective analysis with low economic and environmental impact. Due to the recent focus in sustainability, we report the use of low-cost filter paper as a sustainable material to print silver electrodes and to load reagents for a reagent-free electrochemical detection of chloride in biological samples, namely serum and sweat. The electrochemical detection of chloride ions was carried out by exploiting the reaction of the analyte (i.e. chloride) with the silver working electrode. During the oxidation wave in cyclic voltammetry the silver ions are produced, thus they react with chloride ions to form AgCl, while in the reduction wave, the following reaction occurs: AgCl + e - -->Ag + Cl - . These reactions at the electrode surface resulted in anodic/cathodic peaks directly proportional to the chloride ions in solution. Chloride ions were detected with the addition of only 10μL of the sample on the paper-based electrochemical cell, obtaining linearity up to 200mM with a detection limit equal to 1mM and relative standard deviation lower than 10%. The accuracy of the sensor was evaluated in serum and sweat samples, with percentage recoveries between 93 ± 10 and 108 ± 8%. Moreover, the results achieved with the paper-based device were positively compared with those obtained by using the gold standard method (Ion Selective Electrode) adopted in routine clinical analyses. Copyright © 2017 Elsevier B.V. All rights reserved.
Halpern, Micah D.; Molins, Claudia R.; Schriefer, Martin
2014-01-01
A serology-based tiered approach has, to date, provided the most effective means of laboratory confirmation of clinically suspected cases of Lyme disease, but it lacks sensitivity in the early stages of disease and is often dependent on subjectively scored immunoblots. We recently demonstrated the use of immuno-PCR (iPCR) for detecting Borrelia burgdorferi antibodies in patient serum samples that were positive for Lyme disease. To better understand the performance of the Lyme disease iPCR assay, the repeatability and variability of the background of the assay across samples from a healthy population (n = 36) were analyzed. Both of these parameters were found to have coefficients of variation of <3%. Using eight antigen-specific iPCR assays and positive call thresholds established for each assay, iPCR IgM and/or IgG diagnosis from Lyme disease patient serum samples (n = 12) demonstrated a strong correlation with that of 2-tier testing. Furthermore, a simplified iPCR approach using a single hybrid antigen and detecting only IgG antibodies confirmed the 2-tier diagnosis in the Lyme disease patient serum samples (n = 12). Validation of the hybrid antigen IgG iPCR assay using a blinded panel of Lyme disease and non-Lyme disease patient serum samples (n = 92) resulted in a sensitivity of 69% (95% confidence interval [CI], 50% to 84%), compared to that of the 2-tier analysis at 59% (95% CI, 41% to 76%), and a specificity of 98% (95% CI, 91% to 100%) compared to that of the 2-tier analysis at 97% (95% CI, 88% to 100%). A single-tier hybrid antigen iPCR assay has the potential to be an improved method for detecting host-generated antibodies against B. burgdorferi. PMID:24899074
Taenia solium Infections in a Rural Area of Eastern Zambia-A Community Based Study
Mwape, Kabemba E.; Phiri, Isaac K.; Praet, Nicolas; Muma, John B.; Zulu, Gideon; de Deken, Reginald; Speybroeck, Niko; Dorny, Pierre; Gabriël, Sarah
2012-01-01
Background Taenia solium taeniosis/cysticercosis is a parasitic infection occurring in many developing countries. Data on the status of human infections in Zambia is largely lacking. We conducted a community-based study in Eastern Zambia to determine the prevalence of human taeniosis and cysticercosis in a rural community. Methods and Findings Stool and serum samples were collected from willing participants. Geographical references of the participants' households were determined and household questionnaires administered. Taeniosis was diagnosed in stool samples by coprology and by the polyclonal antibody-based copro-antigen enzyme-linked immunosorbent assay (copro-Ag ELISA), while cysticercosis was diagnosed in serum by the B158/B60 monoclonal antibody-based antigen ELISA (sero-Ag ELISA). Identification of the collected tapeworm after niclosamide treatment and purgation was done using polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). A total of 255 households from 20 villages participated in the study, 718 stool and 708 serum samples were collected and examined. Forty-five faecal samples (6.3%) were found positive for taeniosis on copro-Ag ELISA while circulating cysticercus antigen was detected in 5.8% (41/708) individuals. The tapeworm recovered from one of the cases was confirmed to be T. solium on PCR-RFLP. Seropositivity (cysticercosis) was significantly positively related to age (p = 0.00) and to copro-Ag positivity (taeniosis) (p = 0.03) but not to gender. Change point analysis revealed that the frequency of cysticercus antigens increased significantly in individuals above the age of 30. Copro-Ag positivity was not related to age or gender. The following risk factors were noted to be present in the study community: free-range pig husbandry system and poor sanitation with 47.8% of the households visited lacking latrines. Conclusions This study has recorded high taeniosis and cysticercosis prevalences and identified the need for further studies on transmission dynamics and impact of the disease on the local people. PMID:22479664
Taenia solium Infections in a rural area of Eastern Zambia-a community based study.
Mwape, Kabemba E; Phiri, Isaac K; Praet, Nicolas; Muma, John B; Zulu, Gideon; Van den Bossche, Peter; de Deken, Reginald; Speybroeck, Niko; Dorny, Pierre; Gabriël, Sarah
2012-01-01
Taenia solium taeniosis/cysticercosis is a parasitic infection occurring in many developing countries. Data on the status of human infections in Zambia is largely lacking. We conducted a community-based study in Eastern Zambia to determine the prevalence of human taeniosis and cysticercosis in a rural community. Stool and serum samples were collected from willing participants. Geographical references of the participants' households were determined and household questionnaires administered. Taeniosis was diagnosed in stool samples by coprology and by the polyclonal antibody-based copro-antigen enzyme-linked immunosorbent assay (copro-Ag ELISA), while cysticercosis was diagnosed in serum by the B158/B60 monoclonal antibody-based antigen ELISA (sero-Ag ELISA). Identification of the collected tapeworm after niclosamide treatment and purgation was done using polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). A total of 255 households from 20 villages participated in the study, 718 stool and 708 serum samples were collected and examined. Forty-five faecal samples (6.3%) were found positive for taeniosis on copro-Ag ELISA while circulating cysticercus antigen was detected in 5.8% (41/708) individuals. The tapeworm recovered from one of the cases was confirmed to be T. solium on PCR-RFLP. Seropositivity (cysticercosis) was significantly positively related to age (p = 0.00) and to copro-Ag positivity (taeniosis) (p = 0.03) but not to gender. Change point analysis revealed that the frequency of cysticercus antigens increased significantly in individuals above the age of 30. Copro-Ag positivity was not related to age or gender. The following risk factors were noted to be present in the study community: free-range pig husbandry system and poor sanitation with 47.8% of the households visited lacking latrines. This study has recorded high taeniosis and cysticercosis prevalences and identified the need for further studies on transmission dynamics and impact of the disease on the local people.
Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana
2014-01-01
Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.
Perez-Guaita, David; Kuligowski, Julia; Quintás, Guillermo; Garrigues, Salvador; Guardia, Miguel de la
2013-03-30
Locally weighted partial least squares regression (LW-PLSR) has been applied to the determination of four clinical parameters in human serum samples (total protein, triglyceride, glucose and urea contents) by Fourier transform infrared (FTIR) spectroscopy. Classical LW-PLSR models were constructed using different spectral regions. For the selection of parameters by LW-PLSR modeling, a multi-parametric study was carried out employing the minimum root-mean square error of cross validation (RMSCV) as objective function. In order to overcome the effect of strong matrix interferences on the predictive accuracy of LW-PLSR models, this work focuses on sample selection. Accordingly, a novel strategy for the development of local models is proposed. It was based on the use of: (i) principal component analysis (PCA) performed on an analyte specific spectral region for identifying most similar sample spectra and (ii) partial least squares regression (PLSR) constructed using the whole spectrum. Results found by using this strategy were compared to those provided by PLSR using the same spectral intervals as for LW-PLSR. Prediction errors found by both, classical and modified LW-PLSR improved those obtained by PLSR. Hence, both proposed approaches were useful for the determination of analytes present in a complex matrix as in the case of human serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Xiao, Qin; Hu, Bin; Duan, Jiankun; He, Man; Zu, Wanqing
2007-10-01
A novel method for the analysis of four polybrominated diphenyl ethers (PBDEs) in environmental and human serum samples based on hollow fiber-liquid phase microextraction (HF-LPME) followed by gas chromatography-inductively coupled plasma mass spectrometric (GC-ICP-MS) detection has been developed. The organic solvent in the porous hollow fiber was first dipped into the sample for extraction at a given time, and the retracted organic phase was introduced into the GC-ICP-MS for analysis. The addition of methanol has a strong effect on the HF-LPME extraction efficiency. Other significant parameters affecting the extraction efficiency of HF-LPME were also studied. HF-LPME was effective to isolate the analytes from the complex matrix. Under the optimized conditions, the detection limits of the proposed method varied from 15.2 to 40.5 ng/L. In general, the relative standard deviations (RSDs) were less than 10%. Good linearity was obtained with the correlation coefficients all better than 0.999. The proposed method is simple, quick, few microliters of organic solvent required, and is especially suitable for the analysis of the real sample with small amount available. The overall process of HF-LPME with GC-ICP-MS was applied successfully for the determination of polybrominated diphenyl ethers (PBDEs) in environmental and spiked human serum samples, and the results were satisfactory.
Quantitative bioanalysis of strontium in human serum by inductively coupled plasma-mass spectrometry
Somarouthu, Srikanth; Ohh, Jayoung; Shaked, Jonathan; Cunico, Robert L; Yakatan, Gerald; Corritori, Suzana; Tami, Joe; Foehr, Erik D
2015-01-01
Aim: A bioanalytical method using inductively-coupled plasma-mass spectrometry to measure endogenous levels of strontium in human serum was developed and validated. Results & methodology: This article details the experimental procedures used for the method development and validation thus demonstrating the application of the inductively-coupled plasma-mass spectrometry method for quantification of strontium in human serum samples. The assay was validated for specificity, linearity, accuracy, precision, recovery and stability. Significant endogenous levels of strontium are present in human serum samples ranging from 19 to 96 ng/ml with a mean of 34.6 ± 15.2 ng/ml (SD). Discussion & conclusion: Calibration procedures and sample pretreatment were simplified for high throughput analysis. The validation demonstrates that the method was sensitive, selective for quantification of strontium (88Sr) and is suitable for routine clinical testing of strontium in human serum samples. PMID:28031925
Barlough, J E; Jacobson, R H; Downing, D R; Marcella, K L; Lynch, T J; Scott, F W
1983-01-01
A computer-assisted, kinetics-based enzyme-linked immunosorbent assay was adapted for the detection of coronavirus antibodies in feline serum. An alkaline antigen diluent (carbonate-bicarbonate buffer, pH 9.6) used in initial experiments produced diffuse, nonspecific color reactions in both viral and control antigen cuvettes which were correlated, paradoxically, with coronavirus antibody levels in test sera. These interfering reactions were minimized by use of lower-pH antigen diluents such as water and phosphate-buffered saline. Background kinetics-based enzyme-linked immunosorbent assay reactivity directed against a noncoronaviral component of antigen tissue culture fluids could then detected in numerous sera, particularly in samples with lower titers. Much of this reactivity was shown to be associated with bovine gamma globulins in cell culture fluid. It was not serum lot or species specific, since a variety of bovine serum lots as well as individual lots of serum from other mammalian and avian species reacted. Reactivity was markedly reduced when cells for antigen preparation were grown in gamma globulin-free bovine serum. Generation of corrected slope values from the kinetics-based enzyme-linked immunosorbent assay made it possible to correct for residual background reactivity in individual test sera and thus eliminate a potentially major source of false-positive reactions. Collectively, these studies indicated that the control of nonspecific reactivity in feline coronavirus serology is absolutely essential to obtain useful estimates of specific antibody responses. PMID:6300184
Barlough, J E; Jacobson, R H; Downing, D R; Marcella, K L; Lynch, T J; Scott, F W
1983-02-01
A computer-assisted, kinetics-based enzyme-linked immunosorbent assay was adapted for the detection of coronavirus antibodies in feline serum. An alkaline antigen diluent (carbonate-bicarbonate buffer, pH 9.6) used in initial experiments produced diffuse, nonspecific color reactions in both viral and control antigen cuvettes which were correlated, paradoxically, with coronavirus antibody levels in test sera. These interfering reactions were minimized by use of lower-pH antigen diluents such as water and phosphate-buffered saline. Background kinetics-based enzyme-linked immunosorbent assay reactivity directed against a noncoronaviral component of antigen tissue culture fluids could then detected in numerous sera, particularly in samples with lower titers. Much of this reactivity was shown to be associated with bovine gamma globulins in cell culture fluid. It was not serum lot or species specific, since a variety of bovine serum lots as well as individual lots of serum from other mammalian and avian species reacted. Reactivity was markedly reduced when cells for antigen preparation were grown in gamma globulin-free bovine serum. Generation of corrected slope values from the kinetics-based enzyme-linked immunosorbent assay made it possible to correct for residual background reactivity in individual test sera and thus eliminate a potentially major source of false-positive reactions. Collectively, these studies indicated that the control of nonspecific reactivity in feline coronavirus serology is absolutely essential to obtain useful estimates of specific antibody responses.
Culzoni, María J; Aucelio, Ricardo Q; Escandar, Graciela M
2012-08-31
Based on green analytical chemistry principles, an efficient approach was applied for the simultaneous determination of galantamine, a widely used cholinesterase inhibitor for the treatment of Alzheimer's disease, and its major metabolites in serum samples. After a simple serum deproteinization step, second-order data were rapidly obtained (less than 6 min) with a chromatographic system operating in the isocratic regime using ammonium acetate/acetonitrile (94:6) as mobile phase. Detection was made with a fast-scanning spectrofluorimeter, which allowed the efficient collection of data to obtain matrices of fluorescence intensity as a function of retention time and emission wavelength. Successful resolution was achieved in the presence of matrix interferences in serum samples using multivariate curve resolution-alternating least-squares (MCR-ALS). The developed approach allows the quantification of the analytes at levels found in treated patients, without the need of applying either preconcentration or extraction steps. Limits of detection in the range between 8 and 11 ng mL(-1), relative prediction errors from 7 to 12% and coefficients of variation from 4 to 7% were achieved. Copyright © 2012 Elsevier B.V. All rights reserved.
Petersson, Linn; Dexlin-Mellby, Linda; Bengtsson, Anders A; Sturfelt, Gunnar; Borrebaeck, Carl A K; Wingren, Christer
2014-06-07
In the quest to decipher disease-associated biomarkers, miniaturized and multiplexed antibody arrays may play a central role in generating protein expression profiles, or protein maps, of crude serum samples. In this conceptual study, we explored a novel, 4-times larger pen design, enabling us to, in a unique manner, simultaneously print 48 different reagents (antibodies) as individual 78.5 μm(2) (10 μm in diameter) sized spots at a density of 38,000 spots cm(-2) using dip-pen nanolithography technology. The antibody array set-up was interfaced with a high-resolution fluorescent-based scanner for sensitive sensing. The performance and applicability of this novel 48-plex recombinant antibody array platform design was demonstrated in a first clinical application targeting SLE nephritis, a severe chronic autoimmune connective tissue disorder, as the model disease. To this end, crude, directly biotinylated serum samples were targeted. The results showed that the miniaturized and multiplexed array platform displayed adequate performance, and that SLE-associated serum biomarker panels reflecting the disease process could be deciphered, outlining the use of miniaturized antibody arrays for disease proteomics and biomarker discovery.
Johns, Jennifer L.; Moorhead, Kaitlin A.; Hu, Jing; Moorhead, Roberta C.
2018-01-01
Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended. PMID:29497614
Wang, Meng; Jiao, Yang; Cheng, Chunsheng; Hua, Jianhao; Yang, Yaling
2017-12-01
A novel and sensitive method based on nitrogen-doped carbon quantum dots as a fluorescence probe coupled with magnetic solid-phase extraction (MSPE) purification for analysis of folic acid (FA) in human serum samples has been established for the first time. In the developed system, magnetic nanoparticles coated with hexanoic acid (Fe 3 O 4 @C 6 ) were synthesized by a one-step chemical co-precipitation method with good magnetic properties and dispersibility for sample purification, and it is better to be separated from the sample. High fluorescence nitrogen-doped carbon quantum dots (N-CQDs), simply prepared using a one-step hydrothermal method with nitrilotriacetic acid, could be selectively quenched by FA. Based on this phenomenon, a fluorescence assay was proposed for specific determination of FA. Various operational experiment parameters have been studied and optimized in detail. Under the optimum experimental conditions, the detection limit of the proposed method for FA was evaluated to be 0.5 nM (S/N = 3), while the relative standard deviation (RSD) was 1.2% (n = 6). Finally, the proposed method was applied for determination of trace levels of FA from human serum samples and quantitative recoveries were achieved within the range of 95.7-103.5%. All of the results showed that the proposed method had significant application in further research. Graphical abstract Schematic of synthesis of N-CQDs and schematic of suggested mode for analysis of folic acid (FA).
Feasibility study of feces for noninvasive biomonitoring of brominated flame retardants in toddlers.
Sahlström, Leena M O; Sellström, Ulla; de Wit, Cynthia A; Lignell, Sanna; Darnerud, Per Ola
2015-01-06
This study investigated the feasibility of using feces as a noninvasive matrix to estimate serum concentrations of brominated flame retardants (BFRs) in toddlers for biomonitoring purposes. Tri- to decabrominated diphenyl ethers (tri-decaBDEs), isomer-specific hexabromocyclododecanes, and 16 emerging BFRs were determined in feces from 22 toddlers (11-15 months of age), and results were compared to previously analyzed matched serum samples. BDE-47, -153, -196, -197, -203, -206, -207, -208, and -209 were detected in the feces creating a matched data set (feces-serum, n = 21). Tetra-octaBDE concentrations were significantly higher (Student's paired comparisons t test, α = 0.05) in serum versus feces with BDE-153 having the highest mean difference between the sample matrices. BDE-209 was found in significantly higher concentrations in feces compared to serum. Significant correlations (Pearson's, α = 0.05) between congener-specific concentrations in feces and serum were found for all BDEs except BDE-197 and -203. The feces-serum associations found can be used to estimate serum concentrations of tetra-decaBDEs from feces concentrations and enable a noninvasive sampling method for biomonitoring BDEs in toddlers.
NASA Astrophysics Data System (ADS)
Arsene, Cristian G.; Schulze, Dirk; Kratzsch, Jürgen; Henrion, André
2012-12-01
Amphiphilic peptide conjugation affords a significant increase in sensitivity with protein quantification by electrospray-ionization mass spectrometry. This has been demonstrated here for human growth hormone in serum using N-(3-iodopropyl)-N,N,N-dimethyloctylammonium iodide (IPDOA-iodide) as derivatizing reagent. The signal enhancement achieved in comparison to the method without derivatization enables extension of the applicable concentration range down to the very low concentrations as encountered with clinical glucose suppression tests for patients with acromegaly. The method has been validated using a set of serum samples spiked with known amounts of recombinant 22 kDa growth hormone in the range of 0.48 to 7.65 \\mug/L. The coefficient of variation (CV) calculated, based on the deviation of results from the expected concentrations, was 3.5% and the limit of quantification (LoQ) was determined as 0.4 \\mug/L. The potential of the method as a tool in clinical practice has been demonstrated with patient samples of about 1 \\mug/L.
Singh, Naveen K; Arya, Sunil K; Estrela, Pedro; Goswami, Pranab
2018-06-08
A capacitive aptasensor for detecting the malaria biomarker, Plasmodium falciparum glutamate dehydrogenase (PfGDH), directly in human serum samples developed. A thiolated ssDNA aptamer (NG3) that binds specifically to PfGDH antigen with high affinity (K d = 79 nM) was used to develop the aptasensor. The aptasensor produced capacitance response at an optimized frequency of 2 Hz in a non-Faradaic electrochemical impedance based signal transduction platform. The aptasensor exhibited a wide dynamic range of 100 fM-100 nM with a limits of detection of 0.77 pM in serum samples. The interference from other predominant malarial biomarkers, namely, Plasmodium falciparum -lactate dehydrogenase and -histidine rich protein-II on the aptasensor was negligible. This PfGDH aptasensor with highly sensitive and label free detection capability has great application potential for diagnosis of asymptotic malaria and monitoring the regression of malaria during treatment regime with antimalarial drugs. Copyright © 2018 Elsevier B.V. All rights reserved.
Nyberg, G; Mårtensson, E
1986-01-01
The effects were tested of eight common types of blood collection tubes and two types of "plasma separators" on the stability of the tricyclic antidepressants amitriptyline, imipramine, clomipramine, and their monodemethylated metabolites in venous blood samples. Although EDTA-containing Venoject lavender and Vacutainer lavender tubes seemed to give the most stable plasma samples, and Venoject red the most stable serum samples, the differences were too small to have practical consequences. Vacutainer royal blue collection tubes gave significant losses of greater than 20% of some of the substances. The tubes with serum separator gel or filter proved unsuitable, since they were responsible for losses of greater than 40%. The losses were not caused by redistribution between blood cells and plasma but occurred mainly as a result of contact between the contents and the caps of the tubes. Experiments with freezing, thawing, and storage of samples showed that freshly sampled blood could be stored at room temperature for 24 h in Venoject green tubes without significant losses. Serum samples could be stored at refrigerator temperature for 4 weeks without important losses. Freezing, thawing, and storage at -20 degrees C did not influence the serum or plasma concentrations.
Zhang, Xiaolan; Li, Xiaojing; Jing, Ye; Fang, Xiangming; Zhang, Xinyu; Lei, Bingli; Yu, Yingxin
2017-03-01
Prenatal exposure to polycyclic aromatic hydrocarbons (PAHs) is a high-priority public health concern. However, maternal to fetal transplacental transfer of PAHs has not been systematically studied. To investigate the transplacental transfer of PAHs from mother to fetus and determine the influence of lipophilicity (octanol-water partition coefficient, K OW ) on transfer process, in the present study, we measured the concentrations of 15 PAHs in 95 paired maternal and umbilical cord serum, and placenta samples (in total 285 samples) collected in Shanghai, China. The average concentration of total PAHs was the highest in maternal serums (1290 ng g -1 lipid), followed by umbilical cord serums (1150 ng g -1 lipid). The value was the lowest in placenta samples (673 ng g -1 lipid). Low molecular weight PAHs were the predominant compounds in the three matrices. Increases in fish and meat consumption did not lead to increases in maternal PAH levels, and no obvious gender differences in umbilical cord serums were observed. The widespread presence of PAHs in umbilical cord serums indicated the occurrence of transplacental transfer. The ratios of PAH concentrations in umbilical cord serum to those in maternal serum (F/M) and the concentrations in placenta to those in maternal serum (P/M) of paired samples were analyzed to characterize the transfer process of individual PAHs. Most F/M ratios on lipid basis were close to one (range: 0.79 to 1.36), which suggested that passive diffusion may control the transplacental transfer of PAHs from maternal serum to the fetal circulation. The P/M and F/M values calculated on lipid basis showed that PAHs with lower K OW were more likely to transfer from mother to fetus via the placenta. Copyright © 2016 Elsevier Ltd. All rights reserved.
Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.
2003-01-01
OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429
Ali, Nadeem; Malik, Riffat Naseem; Mehdi, Toufeer; Eqani, Syed Ali Musstjab Akber Shah; Javeed, Aqeel; Neels, Hugo; Covaci, Adrian
2013-04-01
Concentrations of different classes of organohalogenated contaminants (OHCs) viz., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), bromophenols (BPs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and their metabolites were determined in cat and dog serum and hair samples from Pakistan. The major DDT metabolite, p,p'-DDE, was the major OHC in cat serum (N=20) and ranged between 1 and 2150 ng/g lipid weight (lw). p,p'-DDE was not detected in dog serum (N=16). In contrary to other OHCs, levels of ∑HO-PCBs were significantly higher in dog serum (median=6.0 ng/g lw) than cat serum (median=2.2 ng/g lw). Levels of most OHCs were significantly higher (p<0.05) in cat serum than those found in human serum from the same region, in particular for ∑PBDEs (ranged 1-1280 ng/g lw). Significantly lower levels of OCPs (p<0.05) were detected in dog serum than in human serum. The concentrations of ∑BPs were seven times higher in cat serum (median 112 ng/g lw) than dog serum (median 16 ng/g lw). To the best of our knowledge, this is the first time that NBFRs, e.g. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), decabromodiphenylethane (DBDPE), and bis(2-ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), were detected in cat and dog's hair. BTBPE had the highest detection frequency (30%) in the serum samples. In cat and dog hair samples, the order of importance of OHCs was ∑OCPs>∑NBFRs>∑PBDEs>∑PCB, with the highest concentrations being around 38 ng/g hair. In paired hair-serum cat samples (N=12), ∑DDTs (r=0.65, p=0.001) were significantly correlated, while for all other OHCs no significant correlations (p<0.001) were observed in both cats and dogs. Our findings on both hair and serum samples suggested that pet dogs do not bioaccumulate DDTs. Our results are also in agreement with the hypothesis that pets may serve as biosentinels for indoor pollution. This is the first study to document the presence of OHCs in pets from Pakistan and provides baseline information for future monitoring of OHCs in pets. Copyright © 2013 Elsevier B.V. All rights reserved.
Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio
2012-01-01
Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296
Fehm, Tanja; Becker, Sven; Duerr-Stoerzer, Silke; Sotlar, Karl; Mueller, Volkmar; Wallwiener, Diethelm; Lane, Nancy; Solomayer, Erich; Uhr, Jonathan
2007-01-01
Introduction At the time when metastatic disease is identified, assessment of human epidermal growth factor receptor (HER)2 status might help to optimize treatment decisions if HER2 status was not determined at first diagnosis and if HER2 positivity has been acquired during disease progression. Within this context, determination of serum HER2 or evaluation of HER2 status in circulating tumor cells (CTCs) may be of clinical relevance because metastatic tissue may be difficult to obtain for analysis as a result of its localization. The aim of this study was therefore to determine the HER2 status in serum and corresponding CTCs in patients with metastatic breast cancer whose primary tumors were HER2 negative or of unknown HER2 status. Methods Blood samples were obtained from 77 metastatic breast cancer patients with negative (n = 44) or unknown (n = 33) HER2 status. Serum HER2 was determined using a commercial HER2/neu ELISA kit. CTCs were detected by slide-based assay using immunomagnetic enrichment and characterized by phenotyping and genotyping. Alternatively, a commercial kit, based on RT-PCR, was used to detect and characterize CTCs. Results Twenty out of 77 patients with metastatic disease had elevated serum levels of HER2. Blood samples could be analyzed for the presence of CTCs in 67 patients. Eight out of 21 patients with detectable CTCs exhibited HER2 amplification. Twenty-three out of 77 patients were HER2 positive using at least one method. Concordance between HER2 status of CTCs and serum HER2 was observed in 15 of 21 patients (71%). In six patients conflicting results were obtained. Three patients with elevated serum HER2 status had HER2-negative CTCs, whereas three patients with HER2-positive CTCs had normal serum HER2 levels. Conclusion A subgroup of patients with initially negative or unknown HER2 status can have elevated serum HER2 levels and/or HER2-positive CTCs at the time of development of metastatic disease. Although only a small number of patients were studied, our observations are of clinical relevance because, currently, these patients do not have access to HER2-targeted therapy. PMID:17963511
Shafinaz, I S; Moy, F M
2016-03-07
Vitamin D deficiency is highly prevalent in both temperate as well as tropical countries. Obesity is one of the factors contributing to vitamin D deficiency. As our country has a high prevalence of overweight and obesity, we aimed to study serum 25-hydroxyvitamin D (25(OH)D) level and its association with adiposity using various adiposity indicators; and to study other risk factors that affect serum 25(OH)D level among multi-ethnic adults in Kuala Lumpur, Malaysia. This was a cross sectional study conducted with a multistage sampling. All permanent teachers working in government secondary schools in Kuala Lumpur were invited for the study. The data collection included serum 25(OH)D, Parathyroid Hormone (PTH), body fat percentage, waist circumference, body mass index (BMI) and blood pressure. Demographic characteristics, sun avoidance, sun exposure and physical activity were enquired from the participants using a self-administered questionnaire. The data was analyzed using a complex sample analysis. A total of 858 participants were recruited. Majority of them were Malays, females and had tertiary education. The overall prevalence of vitamin D deficiency (<20 ng/ml) was 67.4 %. Indian participants (80.9 %) had the highest proportion of vitamin D deficiency, followed by Malays (75.6 %), others (44.9 %) and Chinese (25.1 %). There was a significant negative association between serum 25(OH)D level with BMI (β = -0.23) and body fat percentage (β = -0.14). In the multivariate linear regression analysis, Malays, Indians and females (p < 0.001); higher BMI and larger waist circumference (p < 0.05) were significantly associated with lower serum 25(OH)D level. The full model explained 32.8 % of the variation between participants in the serum 25(OH)D level. The two most influential factors affecting serum 25(OH)D level were ethnicity and gender. The prevalence of vitamin D deficiency among our participants was high. Adiposity was associated with serum 25(OH)D level. Skin pigmentation and gender based behaviours were more dominant in contributing to serum 25(OH)D level. Health education should be targeted in weight management, gender based behaviours on sun exposure, as skin pigmentation is non-modifiable.
Geographic Model and Biomarker-Derived Measures of Pesticide Exposure and Parkinson’s Disease
RITZ, BEATE; COSTELLO, SADIE
2013-01-01
For more than two decades, reports have suggested that pesticides and herbicides may be an etiologic factor in idiopathic Parkinson’s disease (PD). To date, no clear associations with any specific pesticide have been demonstrated from epidemiological studies perhaps, in part, because methods of reliably estimating exposures are lacking. We tested the validity of a Geographic Information Systems (GIS)-based exposure assessment model that estimates potential environmental exposures at residences from pesticide applications to agricultural crops based on California Pesticide Use Reports (PUR). Using lipid-adjusted dichlorodiphenyldichloroethylene (DDE) serum levels as the “gold standard” for pesticide exposure, we conducted a validation study in a sample taken from an ongoing, population-based case–control study of PD in Central California. Residential, occupational, and other risk factor data were collected for 22 cases and 24 controls from Kern county, California. Environmental GIS–PUR-based organochlorine (OC) estimates were derived for each subject and compared to lipid-adjusted DDE serum levels. Relying on a linear regression model, we predicted log-transformed lipid-adjusted DDE serum levels. GIS–PUR-derived OC measure, body mass index, age, gender, mixing and loading pesticides by hand, and using pesticides in the home, together explained 47% of the DDE serum level variance (adjusted r2 = 0.47). The specificity of using our environmental GIS–PUR-derived OC measures to identify those with high-serum DDE levels was reasonably good (87%). Our environmental GIS–PUR-based approach appears to provide a valid model for assessing residential exposures to agricultural pesticides. PMID:17119217
Chip-LC-MS for label-free profiling of human serum.
Horvatovich, Peter; Govorukhina, Natalia I; Reijmers, Theo H; van der Zee, Ate G J; Suits, Frank; Bischoff, Rainer
2007-12-01
The discovery of biomarkers in easily accessible body fluids such as serum is one of the most challenging topics in proteomics requiring highly efficient separation and detection methodologies. Here, we present the application of a microfluidics-based LC-MS system (chip-LC-MS) to the label-free profiling of immunodepleted, trypsin-digested serum in comparison to conventional capillary LC-MS (cap-LC-MS). Both systems proved to have a repeatability of approximately 20% RSD for peak area, all sample preparation steps included, while repeatability of the LC-MS part by itself was less than 10% RSD for the chip-LC-MS system. Importantly, the chip-LC-MS system had a two times higher resolution in the LC dimension and resulted in a lower average charge state of the tryptic peptide ions generated in the ESI interface when compared to cap-LC-MS while requiring approximately 30 times less (~5 pmol) sample. In order to characterize both systems for their capability to find discriminating peptides in trypsin-digested serum samples, five out of ten individually prepared, identical sera were spiked with horse heart cytochrome c. A comprehensive data processing methodology was applied including 2-D smoothing, resolution reduction, peak picking, time alignment, and matching of the individual peak lists to create an aligned peak matrix amenable for statistical analysis. Statistical analysis by supervised classification and variable selection showed that both LC-MS systems could discriminate the two sample groups. However, the chip-LC-MS system allowed to assign 55% of the overall signal to selected peaks against 32% for the cap-LC-MS system.
Schmidt, Debra A; Pye, Geoffrey W; Hamlin-Andrus, Chris C; Ellis, William A; Bercovitch, Fred B; Ellersieck, Mark R; Chen, Tai C; Holick, Michael F
2013-12-01
As part of a health investigation on koalas at San Diego Zoo, serum samples were analyzed from 18 free-ranging and 22 zoo-based koalas, Phascolarctos cinereus. Serum concentrations of calcium, chloride, cobalt, copper, iron, magnesium, manganese, molybdenum, phosphorus, potassium, selenium, sodium, zinc, and vitamins A, E, and 25(OH)D3 were quantified. Calcium, chloride, molybdenum, selenium, and vitamin E concentrations were significantly higher in zoo-based koalas than in free-ranging koalas, whereas magnesium, manganese, phosphorus, and zinc concentrations were significantly higher in the free-ranging koalas. No significant differences were found between genders. The results from this study will help to establish a starting point for determining target circulating nutrient concentrations in koalas.
Pilot Metabolome-Wide Association Study of Benzo(a)pyrene in Serum from Military Personnel
Walker, Douglas I.; Pennell, Kurt D.; Uppal, Karan; Xia, Xiaoyan; Hopke, Philip K.; Utell, Mark J.; Phipps, Richard P.; Sime, Patricia J.; Rohrbeck, Patricia; Mallon, COL Timothy M.; Jones, Dean P.
2016-01-01
Objective A pilot study was conducted to test the feasibility of using Department of Defense Serum Repository (DoDSR) samples to study health and exposure-related effects. Methods Thirty unidentified human serum samples were obtained from the DoDSR and analyzed for normal serum metabolites with high-resolution mass spectrometry and serum levels of free benzo(a)pyrene (BaP) by gas chromatography-mass spectrometry. Metabolic associations with BaP were determined using a metabolome wide association study (MWAS) and metabolic pathway enrichment. Results The serum analysis detected normal ranges of glucose, selected amino acids, fatty acids, and creatinine. Free BaP was detected in a broad concentration range. MWAS of BaP showed associations with lipids, fatty acids, and sulfur amino acid metabolic pathways. Conclusion The results show the DoDSR samples are of sufficient quality for chemical profiling of DoD personnel. PMID:27501104
Pilot Metabolome-Wide Association Study of Benzo(a)pyrene in Serum From Military Personnel.
Walker, Douglas I; Pennell, Kurt D; Uppal, Karan; Xia, Xiaoyan; Hopke, Philip K; Utell, Mark J; Phipps, Richard P; Sime, Patricia J; Rohrbeck, Patricia; Mallon, Col Timothy M; Jones, Dean P
2016-08-01
A pilot study was conducted to test the feasibility of using Department of Defense Serum Repository (DoDSR) samples to study health and exposure-related effects. Thirty unidentified human serum samples were obtained from the DoDSR and analyzed for normal serum metabolites with high-resolution mass spectrometry and serum levels of free benzo(a)pyrene (BaP) by gas chromatography-mass spectrometry. Metabolic associations with BaP were determined using a metabolome-wide association study (MWAS) and metabolic pathway enrichment. The serum analysis detected normal ranges of glucose, selected amino acids, fatty acids, and creatinine. Free BaP was detected in a broad concentration range. MWAS of BaP showed associations with lipids, fatty acids, and sulfur amino acid metabolic pathways. The results show that the DoDSR samples are of sufficient quality for chemical profiling of DoD personnel.
Gaye, M. M.; Valentine, S. J.; Hu, Y.; Mirjankar, N.; Hammoud, Z. T.; Mechref, Y.; Lavine, B. K.; Clemmer, D. E.
2012-01-01
Three disease phenotypes, Barrett’s esophagus (BE), high-grade dysplasia (HGD), esophageal adenocarcinoma (EAC), and a set of normal control (NC) serum samples are examined using a combination of ion mobility spectrometry (IMS), mass spectrometry (MS) and principal component analysis (PCA) techniques. Samples from a total of 136 individuals were examined, including: 7 characterized as BE, 12 as HGD, 56 as EAC and 61 as NC. In typical datasets it was possible to assign ~20 to 30 glycan ions based on MS measurements. Ion mobility distributions for these ions show multiple features. In some cases, such as the [S1H5N4+3Na]3+ and [S1F1H5N4+3Na]3+ glycan ions, the ratio of intensities of high-mobility features to low-mobility features vary significantly for different groups. The degree to which such variations in mobility profiles can be used to distinguish phenotypes is evaluated for eleven N-linked glycan ions. An outlier analysis on each sample class followed by an unsupervised PCA using a genetic algorithm for pattern recognition reveals that EAC samples are separated from NC samples based on 46 features originating from the 11-glycan composite IMS distribution. PMID:23126309
Regassa, A; Kiarie, E; Sands, J S; Walsh, M C; Kim, W K; Nyachoti, C M
2017-02-01
Effects of substituting cornstarch with D-xylose on growth performance, nutrients digestibility, serum metabolites, and expression of select hepatic genes involved in glucose and lipid metabolism were investigated in broiler chickens. A total of 360 one-day-old male Ross chicks were fed 3 diets (n = 24; 5 chicks/cage) for 21 days. A control corn-soybean meal-based diet with 25% cornstarch was formulated to meet specifications. Two additional diets were formulated by substituting cornstarch with 5 or 15% D-xylose w/w. Growth performance and digestibility by index method were determined in 12 replicate cages. Birds in these replicates had free access to feed and water, the BW and feed intake (FI) were monitored weekly and the excreta samples were collected on d 18 to 20. The other 12 replicates were used for blood and liver sampling by serial slaughter. On d 18, baseline (t0) birds were sampled following a 12 h overnight fasting and birds allowed 30 min access to the feed; samples were subsequently taken at 60, 120, 180, 240, and 300 min post feeding. Serum metabolites (glucose, xylose, and insulin) were assayed at all time points, whereas expression of hepatic transcripts was evaluated at zero, 180 and 300 min. Xylose linearly reduced (P < 0.05) FI, BWG, gross energy digestibility, and feed conversion ratio (FCR) but increased (P < 0.05) serum xylose level. Serum glucose and insulin levels were higher (P < 0.05) in the post-fed state compared with baseline, irrespective of treatments. There was an interaction (P < 0.05) between diet and sampling time on the expression of hepatic genes. At t0, xylose linearly increased (P < 0.05) the expression of pyruvate carboxylase, Acetyl Co-A acethyltransferase 2 (ACAT2), and glucose transporter 2. Xylose linearly reduced (P < 0.05) the expression of ACAT2 at 300 min post feeding. In conclusion, 5% or more xylose reduced growth performance and utilization of nutrients linked to hepatic enzymes and transcription factors involved in glucose and lipid metabolism. © 2016 Poultry Science Association Inc.
Cai, Tanxi; Yang, Fuquan
2017-01-01
Low-molecular-weight region (LMW, MW≤30kDa) of human serum/plasma proteins, including small intact proteins, truncated fragments of larger proteins, along with some other small components, has been associated with the ongoing physiological and pathological events, and thereby represent a treasure trove of diagnostic molecules. Great progress in the mining of novel biomarkers from this diagnostic treasure trove for disease diagnosis and health monitoring has been achieved based on serum samples from healthy individuals and patients and powerful new approaches in biochemistry and systems biology. However, cumulative evidence indicates that many potential LMW protein biomarkers might still have escaped from detection due to their low abundance, the dynamic complexity of serum/plasma, and the limited efficiency of characterization approaches. Here, we provide an overview of the current state of knowledge with respect to strategies for the characterization of low-abundant LMW proteins (small intact or truncated proteins) from human serum/plasma, involving prefractionation or enrichment methods to reduce dynamic range and mass spectrometry-based characterization of low-abundant LMW proteins. © 2017 Elsevier Inc. All rights reserved.
Mimivirus Circulation among Wild and Domestic Mammals, Amazon Region, Brazil
Dornas, Fábio P.; Rodrigues, Felipe P.; Boratto, Paulo V.M.; Silva, Lorena C.F.; Ferreira, Paulo C.P.; Bonjardim, Cláudio A.; Trindade, Giliane S.; Kroon, Erna G.; La Scola, Bernard
2014-01-01
To investigate circulation of mimiviruses in the Amazon Region of Brazil, we surveyed 513 serum samples from domestic and wild mammals. Neutralizing antibodies were detected in 15 sample pools, and mimivirus DNA was detected in 9 pools of serum from capuchin monkeys and in 16 pools of serum from cattle. PMID:24564967
Sahoo, S.; Raghavendra, K. M.; Biswas, S.
2014-01-01
Moringa oleifera Lam. has been an important plant in the history of mankind, both for its nutritional and medicinal uses. Apart from bactericidal effects, the parts of this plant have been effectively used in the treatment of circulatory, respiratory, endocrine, digestive as well as neural disorders. Till date, though, there has been no reported activity of the involvement of any proteinaceous extract from M. oleifera on high levels of serum creatinine. To address this issue, blood samples with high levels of serum creatinine (2 mg/dl and above) were treated with leaf extract from M. oleifera. The crude extract was partially purified initially and eventually purified to completion as well. All these proteinaceous fractions were used to treat samples with high levels of serum creatinine as mentioned above. While the treatment of serum sample having high creatinine with crude extract and partially purified protein fractions showed a decrease of approximately 20% in the levels of serum creatinine over a period of 24 h, the samples treated with purified protein fraction reduced the serum creatinine level by 50%. In light of the fact that increased level of serum creatinine levels have adverse downstream effects on the heart, lungs and other organs, this communication assumes significance because it suggests a way of reducing the level of serum creatinine as an emergency measure. Further, the identification and characterisation of this proteinaceous component and possible in vivo experiments would provide a major tool for the treatment of downstream complications associated with increased serum creatinine via a new sources, albeit a natural one. PMID:24799742
Villa-Mancera, Abel; Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José
2016-01-01
The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans.
Metabonomics identifies serum metabolite markers of colorectal cancer.
Tan, Binbin; Qiu, Yunping; Zou, Xia; Chen, Tianlu; Xie, Guoxiang; Cheng, Yu; Dong, Taotao; Zhao, Linjing; Feng, Bo; Hu, Xiaofang; Xu, Lisa X; Zhao, Aihua; Zhang, Menghui; Cai, Guoxiang; Cai, Sanjun; Zhou, Zhanxiang; Zheng, Minhua; Zhang, Yan; Jia, Wei
2013-06-07
Recent studies suggest that biofluid-based metabonomics may identify metabolite markers promising for colorectal cancer (CRC) diagnosis. We report here a follow-up replication study, after a previous CRC metabonomics study, aiming to identify a distinct serum metabolic signature of CRC with diagnostic potential. Serum metabolites from newly diagnosed CRC patients (N = 101) and healthy subjects (N = 102) were profiled using gas chromatography time-of-flight mass spectrometry (GC-TOFMS) and ultraperformance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-QTOFMS). Differential metabolites were identified with statistical tests of orthogonal partial least-squares-discriminant analysis (VIP > 1) and the Mann-Whitney U test (p < 0.05). With a total of 249 annotated serum metabolites, we were able to differentiate CRC patients from the healthy controls using an orthogonal partial least-squares-discriminant analysis (OPLS-DA) in a learning sample set of 62 CRC patients and 62 matched healthy controls. This established model was able to correctly assign the rest of the samples to the CRC or control groups in a validation set of 39 CRC patients and 40 healthy controls. Consistent with our findings from the previous study, we observed a distinct metabolic signature in CRC patients including tricarboxylic acid (TCA) cycle, urea cycle, glutamine, fatty acids, and gut flora metabolism. Our results demonstrated that a panel of serum metabolite markers is of great potential as a noninvasive diagnostic method for the detection of CRC.
Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José
2016-01-01
The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans. PMID:27563665
McBride, David; Lovelock, Kirsten; Shepherd, Daniel; Dirks, Kim; Welch, David; Gray, Andrew
2016-10-01
The New Zealand Ministry of Health responded to community concern about dioxin exposure during on-site remediation of a pesticide-contaminated rural area by commissioning this exposed-referent study of serum dioxins and health in local residents. All 200 residents were eligible, with age and sex matching to demographically comparable referents. Face-to-face interviews included questions on health status, health-related quality of life (HRQOL) and perceptions about community consultation. Thirty serum samples were obtained, eligibility being based on likelihood of exposure and age. Both HRQOL and serum outcomes were analysed by the appropriate regression methods. Of 200 eligible residents, 139 (69.5%) participated, with 139 matched referents. Mapua residents had lower physical and psychological HRQOL scores, but no difference in health status. 2,3,7,8 TCDD was below the limit of detection in the majority of all serum samples, with some congeners being higher in referents. Perceptions of the communication process were equivocal. Both dioxin levels and measures of health did not differ significantly between the exposed community and controls. Implications for public health: The results suggest neither significant dioxin exposure nor community health effects. Oversight by expert panel with health expertise, allied to sound communication, may have helped the community understand the risks. © 2016 Public Health Association of Australia.
Chantada-Vázquez, María Pilar; Moreda-Piñeiro, Jorge; Cantarero-Roldán, Alicia; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2018-08-15
A novel approach for serum analysis by dried matrix spot (DMS) technique is proposed. The methodology consists of sampling filter paper discs (2.7 mm in diameter) containing the large amount of serum retained after a single spotting. Several oxidizers (sodium chlorate, sodium azide, acetic acid, formic acid, 1-butyl-3-methylimidazoliumm chloride/bromide) were tested (oxidizers premixed with the sample before spotting, and papers previously soaked in concentrated additive/oxidizer solutions). Direct multi-element determination (Al, Be, Ca, Cu, Fe, K, Li, Mg, Mn, Mo, Na, P, Rb, Se, V, and Zn) in dried serum spots at very low levels was therefore assessed by laser ablation (LA) coupled with inductively coupled plasma - mass spectrometry (ICP-MS). Laser ablation was performed using a focused Nd: YAG laser beam in lineal scan mode (wavelength 213 nm, laser fluency 2.2 J cm -2 , repetition rate 20 Hz, laser spot diameter 90 µm, depth 0 µm, scanning speed 12 µm s -1 ). Matrix-matched calibration mode and 13 C as internal standard (for signal intensities normalization) was used throughout the work. Limits of quantification were found to be from 21 µg L -1 to 221 mg L -1 . Repeatability (seven ablations of the same dried serum spot) and reproducibility (two ablations of seven dried serum spot from the same material) offered RSDs below 12% for all analytes, which seems satisfactory for clinical purposes. The method was validated by analyzing several certified reference materials (Seronorm™ level I and II trace elements in serum), and it was applied to several DMS from serum samples from healthy adults. Copyright © 2018 Elsevier B.V. All rights reserved.
Koblavi-Dème, Stéphania; Maurice, Chantal; Yavo, Daniel; Sibailly, Toussaint S.; N′guessan, Kabran; Kamelan-Tano, Yvonne; Wiktor, Stefan Z.; Roels, Thierry H.; Chorba, Terence; Nkengasong, John N.
2001-01-01
To evaluate serologic testing algorithms for human immunodeficiency virus (HIV) based on a combination of rapid assays among persons with HIV-1 (non-B subtypes) infection, HIV-2 infection, and HIV-1–HIV-2 dual infections in Abidjan, Ivory Coast, a total of 1,216 sera with known HIV serologic status were used to evaluate the sensitivity and specificity of four rapid assays: Determine HIV-1/2, Capillus HIV-1/HIV-2, HIV-SPOT, and Genie II HIV-1/HIV-2. Two serum panels obtained from patients recently infected with HIV-1 subtypes B and non-B were also included. Based on sensitivity and specificity, three of the four rapid assays were evaluated prospectively in parallel (serum samples tested by two simultaneous rapid assays) and serial (serum samples tested by two consecutive rapid assays) testing algorithms. All assays were 100% sensitive, and specificities ranged from 99.4 to 100%. In the prospective evaluation, both the parallel and serial algorithms were 100% sensitive and specific. Our results suggest that rapid assays have high sensitivity and specificity and, when used in parallel or serial testing algorithms, yield results similar to those of enzyme-linked immunosorbent assay-based testing strategies. HIV serodiagnosis based on rapid assays may be a valuable alternative in implementing HIV prevention and surveillance programs in areas where sophisticated laboratories are difficult to establish. PMID:11325995
Metabolic indicators of habitat differences in four Minnesota deer populations
Seal, U.S.; Nelson, M.E.; Mech, L.D.; Hoskinson, R.L.
1978-01-01
Blood samples were collected from 40 white-tailed deer (Odocoileus virginianus) from 4 winter yards in northeastern Minnesota from 17 March 1974 through 23 April 1975. The results of 26 blood assays were examined for the effects of age, sex, capture date, capture method, disease and location. Age-related effects were found for serum chloride, calcium, gamma globulin, creatine phosphokinase (CPK), lactic dehydrogenase (LDH), and alkaline phosphatase. The only sex difference was lower CPK in males. Date of collection effects were found for erythrocyte count, mean corpuscular volume (MCV), serum glucose, and nonesterified fatty acids (NEF A). Capture method affected serum glucose, acid base balance, and serum enzymes. Effects related primarily to capture location or habitat differences were found for erythrocyte count, MCV, mean corpuscular hemoglobin concentration (MCHC), serum urea, cholesterol, LDH, thyroxine, and NEF A. Animals whose assays indicated the poorest nutritional status inhabited wintering areas with the oldest vegetation. Habitat differences can be detected by measuring the physiological status of the local animal populations.
NASA Astrophysics Data System (ADS)
Cheng, Jin-ying; Xu, Liang; Lü, Guo-dong; Tang, Jun; Mo, Jia-qing; Lü, Xiao-yi; Gao, Zhi-xian
2017-01-01
A Raman spectroscopy method combined with neural network is used for the invasive and rapid detection of echinococcosis. The Raman spectroscopy measurements are performed on two groups of blood serum samples, which are from 28 echinococcosis patients and 38 healthy persons, respectively. The normalized Raman reflection spectra show that the reflectivity of the echinococcosis blood serum is higher than that of the normal human blood serum in the wavelength ranges of 101—175 nm and 1 801—2 701 nm. Then the principal component analysis (PCA) and back propagation neural network (BPNN) model are used to obtain the diagnosis results. The diagnosis rates for healthy persons and echinococcosis persons are 93.333 3% and 90.909 1%, respectively, so the average final diagnosis rate is 92.121 2%. The results demonstrate that the Raman spectroscopy analysis of blood serum combined with PCA-BPNN has considerable potential for the non-invasive and rapid detection of echinococcosis.
[Value of polymerase chain reaction in serum for the diagnosis of enteroviral meningitis].
Marque Juillet, S; Lion, M; Pilmis, B; Tomini, E; Dommergues, M-A; Laporte, S; Foucaud, P
2013-06-01
Enteroviruses (EV) are a common cause of aseptic meningitis in children. Virological diagnosis of EV meningitis is currently based on the detection of the viral genome in the cerebrospinal fluid (CSF). This study attempted to determine the correlation and the temporality of the polymerase chain reaction (PCR) assay in serum and CSF and to evaluate the possibility of diagnosing EV infection only on the serum PCR. The EV genome was sought by RT real-time PCR (Smart Cycler EV Primer and Probe Set(®), Cepheid) in CSF and serum, collected at the same time, for all children who underwent a lumbar puncture for suspected meningitis, between 1 June and 31 July 2010 at the Versailles Hospital. Forty-four patients were included in the study. EV infection was documented for 22 of them. In 10 patients, the EV genome was detected in CSF only; in 3 patients in serum only, and in 9 patients in both. Among patients with acute EV neurological infection, viremic children were significantly younger (1.6 months versus 5.8 years; P<0.001). Viremia was detected when the serum was sampled within 30 h after the beginning of symptoms. These results confirm previous reports of early and transient viremia in young children. This preliminary study shows the limits and added value of EV PCR in serum. It suggests that in some children and under certain conditions (age >3 months, clinical and biological compatibility with a viral infection, no previous antibiotic therapy, time from symptom onset to blood sampling <30 h, PCR in serum analyzed within 3h), PCR in serum, when positive, is a possible alternative. Therefore, it may be possible to diagnose EV infection without performing a lumbar puncture in a limited number of young children (11.4% of our suspected cases). This study needs to be reinforced by a multicenter study with a broader panel of patients. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Friedrich, Nele; Milman, Nils; Völzke, Henry; Linneberg, Allan; Jørgensen, Torben
2009-08-01
The 'iron hypothesis' claims that Fe depletion protects against IHD. The objective of the present study was to investigate the associations between serum ferritin levels and the risk of CVD and IHD in a population-based sample. A total of 2874 subjects with serum ferritin levels between 15 and 300 microg/l from the Danish part of the 'Monitoring of Trends and Determinants in Cardiovascular Disease' (DAN-MONICA) I study and the 1914 Cohort survey were followed for 10 years. Information on behavioural and socio-demographic characteristics were collected and serum ferritin levels measured. Non-fatal and fatal CVD and IHD were identified by the International Classification of Diseases diagnoses numbers. Multivariable Cox proportional hazard regression models with restricted cubic splines were performed. During the follow-up period, 310 subjects (201 men; 109 women) and 161 subjects (117 men; forty-four women) experienced CVD and IHD, respectively. Our analyses revealed no statistically significant associations between serum ferritin levels and the risk of CVD or IHD in both sexes. However, in women, the results argue for a U-shaped relationship between serum ferritin levels and CVD as well as IHD. In concordance with former prospective studies, the present results do not support the hypothesis that normal body Fe stores should play a significant role in the development of CVD.
Wei, Kai; Zhang, Haiyan; Zhang, Yuewei; Xu, Jian; Jiang, Fei; Liu, Xu; Xu, Wei; Wu, Wenxue
2014-01-01
The pathogen Mycoplasma bovis (M. bovis) is a major cause of respiratory disease, mastitis, and arthritis in cattle. Screening the key immunogenic proteins and updating rapid diagnostic techniques are necessary to the prevention and control of M. bovis infection. In this study, 19 highly immunogenic proteins from M. bovis strain PD were identified using 2-dimensional gel electrophoresis, immunoblotting and MALDI-TOF/TOF MS. Of these 19 proteins, pyruvate dehydrogenase E1 component beta subunit (PDHB) showed excellent immune reactivity and repeatability. PDHB was found to be conserved in different M. bovis isolates, as indicated by Western blot analysis. On the basis of these results, a rPDHB-based indirect ELISA (iELISA) was established for the detection of serum antibodies using prokaryotically expressed recombinant PDHB protein as the coating antigen. The specificity analysis result showed that rPDHB-based iELISA did not react with other pathogens assessed in our study except M. agalactiae (which infects sheep and goats). Moreover, 358 serum samples from several disease-affected cattle feedlots were tested using this iELISA system and a commercial kit, which gave positive rates of 50.8% and 39.9%, respectively. The estimated Kappa agreement coefficient between the two methods was 0.783. Notably, 39 positive serum samples that had been missed by the commercial kit were all found to be positive by Western blot analysis. The detection rate of rPDHB-based iELISA was significantly higher than that of the commercial kit at a serum dilution ratio of 1∶5120 to 1∶10,240 (P<0.05). Taken together, these results provide important information regarding the novel immunogenic proteins of M. bovis. The established rPDHB-based iELISA may be suitable for use as a new method of antibody detection in M. bovis. PMID:24520369
Zhao, Mei-Fen; Huang, Peng; Ge, Chun-Lin; Sun, Tao; Ma, Zhi-Gang; Ye, Fei-Fei
2016-02-28
To identify conjugated bile acids in gallbladder bile and serum as possible biomarkers for cholesterol polyps (CPs) and adenomatous polyps (APs). Gallbladder bile samples and serum samples were collected from 18 patients with CPs (CP group), 9 patients with APs (AP group), and 20 patients with gallstones (control group) from March to November, 2013. High performance liquid chromatography (HPLC) assay with ultraviolent detection was used to detect the concentration of 8 conjugated bile acids (glycocholic acid, GCA; taurocholic acid, TCA; glycochenodeoxycholic acid, GCDCA; taurochenodeoxycholic acid, TCDCA; glycodeoxycholic acid, GDCA; taurodeoxycholic acid, TDCA; taurolithocholic acid, TLCA; tauroursodeoxycholic acid, TUDCA) in bile samples and serum samples. The diagnostic efficacy of serum GCA, GCDCA and TCDCA was evaluated. These 8 conjugated bile acids in gallbladder bile and serum were completely identified within 10 minutes with good linearity (correlation coefficient: R>0.9900; linearity range: 3.91-500 µg/mL). Among these conjugated bile acids, the levels of gallbladder bile GCDCA and TCDCA in the CP group were significantly higher than those in the AP group (p<0.05). Furthermore, serum GCDCA and TCDCA as well as GCA were significantly higher in the AP group than the CP group (p<0.05). Serum GCDCA alone (≤12 µg/mL) had relatively better diagnostic efficacy than the other conjugated bile acids. The levels of serum GCA, GCDCA and TCDCA may be valuable for differentiation of APs and CPs.
Polyfluoroalkyl substance exposure in the Mid-Ohio River Valley, 1991-2012.
Herrick, Robert L; Buckholz, Jeanette; Biro, Frank M; Calafat, Antonia M; Ye, Xiaoyun; Xie, Changchun; Pinney, Susan M
2017-09-01
Industrial discharges of perfluorooctanoic acid (PFOA) to the Ohio River, contaminating water systems near Parkersburg, WV, were previously associated with nearby residents' serum PFOA concentrations above US general population medians. Ohio River PFOA concentrations downstream are elevated, suggesting Mid-Ohio River Valley residents are exposed through drinking water. Quantify PFOA and 10 other per- and polyfluoroalkyl substances (PFAS) in Mid-Ohio River Valley resident sera collected between 1991 and 2013 and determine whether the Ohio River and Ohio River Aquifer are exposure sources. We measured eleven PFAS in 1608 sera from 931 participants. Serum PFOA concentration and water source associations were assessed using linear mixed-effects models. We estimated between-sample serum PFOA using one-compartment pharmacokinetics for participants with multiple samples. In serum samples collected as early as 1991, PFOA (median = 7.6 ng/mL) was detected in 99.9% of sera; 47% had concentrations greater than US population 95th percentiles. Five other PFAS were detected in greater than 82% of samples; median other PFAS concentrations were similar to the US general population. Serum PFOA was significantly associated with water source, sampling year, age at sampling, tap water consumption, pregnancy, gravidity and breastfeeding. Serum PFOA was 40-60% lower with granular activated carbon (GAC) use. Repeated measurements and pharmacokinetics suggest serum PFOA peaked 2000-2006 for participants using water without GAC treatment; where GAC was used, serum PFOA concentrations decreased from 1991 to 2012. Mid-Ohio River Valley residents appear to have PFOA, but not other PFAS, serum concentrations above US population levels. Drinking water from the Ohio River and Ohio River Aquifer, primarily contaminated by industrial discharges 209-666 km upstream, is likely the primary exposure source. GAC treatment of drinking water mitigates, but does not eliminate, PFOA exposure. Copyright © 2017 Elsevier Ltd. All rights reserved.
Parkinson, I S; Ward, M K; Kerr, D N
1982-10-27
A simple but reliable method for the routine determination of aluminium in serum and water by flameless atomic absorption spectrometry is described. No preparatory procedures are required for water samples, although serum is mixed with a wetting agent (Triton X-100) to allow complete combustion of the samples and to improve analytical precision. Precautions to prevent contamination during sample handling are discussed and instrumental parameters are defined. The method has a sensitivity of 35.5 pg and detection limits of 2.3 micrograms Al/l for serum and 1.3 micrograms Al/l for water. The method was used to determine the aluminium concentration in serum of 46 normal subjects. The mean aluminium content was 7.3 micrograms/l (range 2--15 micrograms/l.
Ratio between serum IL-8 and pepsinogen A/C: a marker for atrophic body gastritis.
Sanduleanu, S; Bruïne, A D E; Biemond, I; Stridsberg, M; Jonkers, D; Lundqvist, G; Hameeteman, W; Stockbrügger, R W
2003-02-01
Elevated serum gastrin and a low pepsinogen A/C ratio are well-recognized markers for atrophic body gastritis (ABG). We have shown that the presence of body atrophy is also associated with elevated serum pro-inflammatory cytokines. This study tested the hypothesis that serum cytokines provide additional information to gastrin and pepsinogens in screening for ABG. Two hundred and twenty-six consecutive patients were investigated on referral for upper gastrointestinal endoscopy: 150 were patients with gastro-oesophageal reflux disease, receiving acid inhibitory medication either with proton pump inhibitors (n = 113) or with histamine2-receptor antagonists (n = 37), and 76 were nontreated controls, who had normal endoscopic findings. Gastric mucosal biopsies were sampled for histological examination (Sydney classification). Serum samples were analyzed for gastrin, chromogranin A (CgA), and pepsinogens A and C by RIA, and for the interleukins (IL)-1beta, IL-6, and IL-8 by ELISA. Subjects with ABG had significantly higher serum gastrin (P < 0.01) and serum CgA (P < 0.01) levels and significantly lower pepsinogen A/C ratios (P < 0.001) than those without ABG. Additionally, serum IL-1beta, IL-6 and, especially, IL-8 levels were significantly higher in the subjects with than in those without ABG (P < 0.0001, for all cytokines). To optimize the detection of body atrophy we defined the ABG index: the ratio between the simultaneously measured IL-8 and pepsinogen A/C. The area under the ROC curve for the ABG index was significantly greater than that for serum gastrin and for serum pepsinogen A/C alone (0.91 +/- 0.029 vs. 0.72 +/- 0.042, and vs. 0.83 +/- 0.031, P = 0.018 and P = 0.049). Using the ABG index at a cut-off value of 1.8 pg mL-1, 91% of the cases were classified correctly. The ratio between serum IL-8 and pepsinogen A/C accurately predicts the presence of ABG. We therefore propose the ABG index as a noninvasive screening test for ABG in population-based studies.
Serum factors and clinical characteristics associated with serum E-Screen activity
Wang, Jue; Trentham-Dietz, Amy; Hemming, Jocelyn D. C.; Hedman, Curtis J.; Sprague, Brian L.
2013-01-01
Background The E-Screen bioassay can measure the mitogenicity of human serum and thus may be useful as a biomarker in epidemiologic studies of breast cancer. While the assay’s MCF-7 cells are known to proliferate in response to estrogen, the specific determinants of variation in E-Screen activity in human serum samples are poorly understood. We sought to identify serum molecules and patient characteristics associated with serum E-Screen activity among postmenopausal women. Methods Postmenopausal women (N=219) aged 55–70 with no history of postmenopausal hormone use or breast cancer completed a questionnaire and provided a blood sample. Serum was analyzed for E-Screen activity and a variety of molecules including sex hormones, growth factors, and environmental chemicals. Stepwise selection procedures were used to identify correlates of E-Screen activity. Results Serum samples from all women had detectable E-Screen activity, with a median estradiol equivalents value of 0.027 ng/mL and interquartile range of 0.018–0.036 ng/mL. In the final multivariable-adjusted model, serum E-Screen activity was positively associated with serum estradiol, estrone, IGFBP-3, and testosterone levels (p<0.05), as well as body mass index (p=0.03). Serum E-Screen activity was lower among women with higher SHBG (p<0.0001) and progesterone levels (p=0.03). Conclusion Serum E-Screen activity varies according to levels of endogenous estrogens and other serum molecules. Obesity appears to confer additional serum mitogenicity beyond its impact on the measured hormones and growth factors. Impact By capturing mitogenicity due to a variety of patient and serum factors, the E-Screen may provide advantages for use as a biomarker in breast cancer studies. PMID:23588007
NASA Astrophysics Data System (ADS)
Matveeva, Evgenia G.; Gryczynski, Ignacy; Berndt, Klaus W.; Lakowicz, Joseph R.; Goldys, Ewa; Gryczynski, Zygmunt
2006-02-01
We present a novel approach for performing fluorescence immunoassay in serum and whole blood using fluorescently labeled anti-rabbit IgG. This approach, which is based on Surface Plasmon-Coupled Emission (SPCE), provides increased sensitivity and substantial background reduction due to exclusive selection of the signal from the fluorophores located near a bio-affinity surface. Effective coupling range for SPCE is only couple of hundred nanometers from the metallic surface. Excited fluorophores outside the coupling layer do not contribute to SPCE, and their free-space emission is not transmitted through the opaque metallic film into the glass substrate. An antigen (rabbit IgG) was adsorbed to a slide covered with a thin silver metal layer, and the SPCE signal from the fluorophore-labeled anti-rabbit antibody, binding to the immobilized antigen, was detected. The effect of the sample matrix (buffer, human serum, or human whole blood) on the end-point immunoassay SPCE signal is discussed. The kinetics of binding could be monitored directly in whole blood or serum. The results showed that human serum and human whole blood attenuate the SPCE end-point signal and the immunoassay kinetic signal only approximately 2- and 3-fold, respectively (compared to buffer), resulting in signals that are easily detectable even in whole blood. The high optical absorption of the hemoglobin can be tolerated because only fluorophores within a couple of hundred nanometers from the metallic film contribute to SPCE. Both glass and plastic slides can be used for SPCE-based assays. We believe that SPCE has the potential of becoming a powerful approach for performing immunoassays based on surface-bound analytes or antibodies for many biomarkers directly in dense samples such as whole blood, without any need for washing steps.
Hényková, Eva; Vránová, Hana Přikrylová; Amakorová, Petra; Pospíšil, Tomáš; Žukauskaitė, Asta; Vlčková, Magdaléna; Urbánek, Lubor; Novák, Ondřej; Mareš, Jan; Kaňovský, Petr; Strnad, Miroslav
2016-03-11
Many compounds related to L-tryptophan (L-TRP) have interesting biological or pharmacological activity, and their abnormal neurotransmission seems to be linked to a wide range of neurodegenerative and psychiatric diseases. A high-throughput method based on ultra-high performance liquid chromatography connected to electrospray tandem mass spectrometry (UHPLC-ESI-MS/MS) was developed for the quantitative analysis of L-TRP and 16 of its metabolites in human serum and cerebrospinal fluid (CSF), representing both major and minor routes of L-TRP catabolism. The combination of a fast LC gradient with selective tandem mass spectrometry enabled accurate analysis of almost 100 samples in 24h. The standard isotope dilution method was used for quantitative determination. The method's lower limits of quantification for serum and cerebrospinal fluid ranged from 0.05 to 15nmol/L and 0.3 to 45nmol/L, respectively. Analytical recoveries ranged from 10.4 to 218.1% for serum and 22.1 to 370.0% for CSF. The method's accuracy ranged from 82.4 to 128.5% for serum matrix and 90.7 to 127.7% for CSF matrix. All intra- and inter-day coefficients of variation were below 15%. These results demonstrate that the new method is capable of quantifying endogenous serum and CSF levels of a heterogeneous group of compounds spanning a wide range of concentrations. The method was used to determine the physiological levels of target analytes in serum and CSF samples from 18 individuals, demonstrating its reliability and potential usefulness in large-scale epidemiological studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Abdelwahab, Mohamed; Loa, Chien Chang; Wu, Ching Ching; Lin, Tsang Long
2015-06-01
Nucleocapsid (N) protein gene of turkey coronavirus (TCoV) was expressed in a prokaryotic system and used to develop an enzyme-linked immunosorbent assay (ELISA) for detection of antibody to TCoV. Anti-TCoV hyperimmune turkey serum and normal turkey serum were used as positive or negative controls for optimization of the ELISA. Goat anti-turkey IgG (H+L) conjugated with horseradish peroxidase was used as detector antibody. Three hundred and twenty two turkey sera from the field were used to evaluate the performance of ELISA and determine the cut-off point of ELISA. The established ELISA was also examined with serum samples obtained from turkeys experimentally infected with TCoV. Those serum samples were collected at various time intervals from 1 to 63 days post-infection. The optimum conditions for differentiation between anti-TCoV hyperimmune serum and normal turkey serum were recombinant TCoV N protein concentration at 20 μg/ml, serum dilution at 1:800, and conjugate dilution at 1:10,000. Of the 322 sera from the field, 101 were positive for TCoV by immunofluorescent antibody assay (IFA). The sensitivity and specificity of the ELISA relative to IFA test were 86.0% and 96.8%, respectively, using the optimum cut-off point of 0.2 as determined by logistic regression method. Reactivity of anti-rotavirus, anti-reovirus, anti-adenovirus, or anti-enterovirus antibodies with the recombinant N protein coated on the ELISA plates was not detected. These results indicated that the established antibody-capture ELISA in conjunction with recombinant TCoV N protein as the coating protein can be utilized for detection of antibodies to TCoV in turkey flocks. Copyright © 2015 Elsevier B.V. All rights reserved.
Korosue, Kenji; Murase, Harutaka; Sato, Fumio; Ishimaru, Mutsuki; Kotoyori, Yasumitsu; Nambo, Yasuo
2012-11-01
The object of this study was to evaluate the usefulness of measuring the differences in the values of the serum total protein (DVSTP) concentration of foals and the refractometry index (DVRI) of the milk of dams before and after nursing of the colostrum for assessing failure of passive transfer (FPT) in foals. Serum samples from 31 foals were collected before the first nursing and other 1 to 6 times between 4 and 24 hr after birth. Paired colostrum and milk samples were collected from 14 of their dams at the same time. Serum samples were analyzed for IgG concentration using a single radial immunodiffusion (SRID) test (98 samples) and total protein concentration using a temperature-compensating refractometer (98 samples). Colostrum and milk samples were analyzed for refractometry index (RI) using a Brix refractometer (71 samples). DVSTP concentration and DVRI were significantly correlated with serum IgG concentration. The negative predictive values (NPVs) of DVSTP concentration for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 98.2% and 91.3% when the cutoff value is set to 0.4 mg/dl and 0.8 mg/dl, respectively. Furthermore, the NPVs of DVRI for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 97.3% and 96.3% when the cutoff value is set to 6% and 10%, respectively. The results suggest that measurement of DVRI is useful in assessing FPT as an initial "stall-side" screening test, because it is easy, inexpensive to perform and allows for rapid interpretation.
Jafari, M T; Rezaei, B; Zaker, B
2009-05-01
Application of ion mobility spectrometry (IMS) as the detection technique for a separation method based on molecular imprinted polymer (MIP) was investigated and evaluated for the first time. On the basis of the results obtained in this work, the MIP-IMS system can be used as a powerful technique for separation, preconcentration, and detection of the metronidazole drug in pharmaceutical and human serum samples. The method is exhaustively validated in terms of sensitivity, selectivity, recovery, reproducibility, and column capacity. The linear dynamic range of 0.05-70.00 microg/mL was obtained for the determination of metronidazole with IMS. The recovery of analyzed drug was calculated to be above 89%, and the relative standard deviation (RSD) was lower than 6% for all experiments. Various real samples were analyzed with the coupled techniques, and the results obtained revealed the efficient cleanup of the samples using MIP separation before the analysis by IMS as a detection technique.
Desmopressin to Prevent Rapid Sodium Correction in Severe Hyponatremia: A Systematic Review.
MacMillan, Thomas E; Tang, Terence; Cavalcanti, Rodrigo B
2015-12-01
Hyponatremia is common among inpatients and is associated with severe adverse outcomes such as osmotic demyelination syndrome. Current guidelines recommend serum sodium concentration correction targets of no more than 8 mEq/L per day in patients at high risk of osmotic demyelination syndrome. Desmopressin is recommended to control high rates of serum sodium concentration correction in severe hyponatremia. However, recommendations are based on limited data. The objective of this study is to review current strategies for DDAVP use in severe hyponatremia. Systematic literature search of 4 databases of peer-reviewed studies was performed and study quality was appraised. The literature search identified 17 observational studies with 80 patients. We found 3 strategies for desmopressin administration in hyponatremia: 1) proactive, where desmopressin is administered early based on initial serum sodium concentration; 2) reactive, where desmopressin is administered based on changes in serum sodium concentration or urine output; 3) rescue, where desmopressin is administered after serum sodium correction targets are exceeded or when osmotic demyelination appears imminent. A proactive strategy of desmopressin administration with hypertonic saline was associated with lower incidence of exceeding serum sodium concentration correction targets, although this evidence is derived from a small case series. Three distinct strategies for desmopressin administration are described in the literature. Limitations in study design and sample size prevent definitive conclusions about the optimal strategy for desmopressin administration to correct hyponatremia. There is a pressing need for better quality research to guide clinicians in managing severe hyponatremia. Copyright © 2015 Elsevier Inc. All rights reserved.
Galesloot, Tessel E.; van Dijk, Freerk; Geurts-Moespot, Anneke J.; Girelli, Domenico; Kiemeney, Lambertus A. L. M.; Sweep, Fred C. G. J.; Swertz, Morris A.; van der Meer, Peter; Camaschella, Clara; Toniolo, Daniela; Vermeulen, Sita H.; van der Harst, Pim; Swinkels, Dorine W.
2016-01-01
Serum hepcidin concentration is regulated by iron status, inflammation, erythropoiesis and numerous other factors, but underlying processes are incompletely understood. We studied the association of common and rare single nucleotide variants (SNVs) with serum hepcidin in one Italian study and two large Dutch population-based studies. We genotyped common SNVs with genome-wide association study (GWAS) arrays and subsequently performed imputation using the 1000 Genomes reference panel. Cohort-specific GWAS were performed for log-transformed serum hepcidin, adjusted for age and gender, and results were combined in a fixed-effects meta-analysis (total N 6,096). Six top SNVs (p<5x10-6) were genotyped in 3,821 additional samples, but associations were not replicated. Furthermore, we meta-analyzed cohort-specific exome array association results of rare SNVs with serum hepcidin that were available for two of the three cohorts (total N 3,226), but no exome-wide significant signal (p<1.4x10-6) was identified. Gene-based meta-analyses revealed 19 genes that showed significant association with hepcidin. Our results suggest the absence of common SNVs and rare exonic SNVs explaining a large proportion of phenotypic variation in serum hepcidin. We recommend extension of our study once additional substantial cohorts with hepcidin measurements, GWAS and/or exome array data become available in order to increase power to identify variants that explain a smaller proportion of hepcidin variation. In addition, we encourage follow-up of the potentially interesting genes that resulted from the gene-based analysis of low-frequency and rare variants. PMID:27846281
Wu, Chang-Lin; He, Jian-An; Gu, Da-Yong; Shao, Chao-Peng; Zhu, Yi; Dang, Xin-Tang
2018-01-01
This study was aimed to establish a novel strategy based on the surface plasmon resonance (SPR) technology for platelet compatibility testing. A novel surface matrix was prepared based on poly (OEGMA-co-HEMA) via surface-initiated polymerization as a biosensor surface platform. Type O universal platelets and donor platelets were immobilized on these novel matrices via amine-coupling reaction and worked as a capturing ligand for binding the platelet antibody. Antibodies binding to platelets were monitored in real time by injecting the samples into a microfluidic channel. Clinical serum samples (n = 186) with multiple platelet transfusions were assayed for platelet antibodies using the SPR technology and monoclonal antibody-immobilized platelet antigen (MAIPA) assay. The novel biosensor surface achieved nonfouling background and high immobilization capacity and showed good repeatability and stability after regeneration. The limit of detection of the SPR biosensor for platelet antibody was estimated to be 50 ng/mL. The sensitivity and specificity were 92% and 98.7%. It could detect the platelet antibody directly in serum samples, and the results were similar to MAIPA assay. A novel strategy to facilitate the sensitive and reliable detection of platelet compatibility for developing an SPR-based biosensor was established in this study. The SPR-based biosensor combined with novel surface chemistry is a promising method for platelet compatibility testing.
Influence of the collection tube on metabolomic changes in serum and plasma.
López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D
2016-04-01
Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Helwa, Inas; Cai, Jingwen; Drewry, Michelle D; Zimmerman, Arthur; Dinkins, Michael B; Khaled, Mariam Lotfy; Seremwe, Mutsa; Dismuke, W Michael; Bieberich, Erhard; Stamer, W Daniel; Hamrick, Mark W; Liu, Yutao
2017-01-01
Exosomes play a role in cell-to-cell signaling and serve as possible biomarkers. Isolating exosomes with reliable quality and substantial concentration is a major challenge. Our purpose is to compare the exosomes extracted by three different exosome isolation kits (miRCURY, ExoQuick, and Invitrogen Total Exosome Isolation Reagent) and differential ultracentrifugation (UC) using six different volumes of a non-cancerous human serum (5 ml, 1 ml, 500 μl, 250 μl, 100 μl, and 50 μl) and three different volumes (1 ml, 500 μl and 100 μl) of six individual commercial serum samples collected from human donors. The smaller starting volumes (100 μl and 50 μl) are used to mimic conditions of limited availability of heterogeneous biological samples. The isolated exosomes were characterized based upon size, quantity, zeta potential, CD63 and CD9 protein expression, and exosomal RNA (exRNA) quality and quantity using several complementary methods: nanoparticle tracking analysis (NTA) with ZetaView, western blot, transmission electron microscopy (TEM), the Agilent Bioanalyzer system, and droplet digital PCR (ddPCR). Our NTA results showed that all isolation techniques produced exosomes within the expected size range (40-150 nm). The three kits, though, produced a significantly higher yield (80-300 fold) of exosomes as compared to UC for all serum volumes, except 5 mL. We also found that exosomes isolated by the different techniques and serum volumes had similar zeta potentials to previous studies. Western blot analysis and TEM immunogold labelling confirmed the expression of two common exosomal protein markers, CD63 and CD9, in samples isolated by all techniques. All exosome isolations yielded high quality exRNA, containing mostly small RNA with a peak between 25 and 200 nucleotides in size. ddPCR results indicated that exosomes isolated from similar serum volumes but different isolation techniques rendered similar concentrations of two selected exRNA: hsa-miR-16 and hsa-miR-451. In summary, the three commercial exosome isolation kits are viable alternatives to UC, even when limited amounts of biological samples are available.
Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K
2012-04-30
Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.
Kumar, Jyoti S; Saxena, Divyasha; Parida, Manmohan
2014-01-01
The recent outbreaks of West Nile Virus (WNV) in the Northeastern American continents and other regions of the world have made it essential to develop an efficient protocol for surveillance of WN virus. Nucleic acid based techniques like, RT-PCR have the advantage of sensitivity, specificity and rapidity. A one step single tube Env gene specific real-time RT-PCR was developed for early and reliable clinical diagnosis of WNV infection in clinical samples. The applicability of this assay for clinical diagnosis was validated with 105 suspected acute-phase serum and plasma samples from the recent epidemic of mysterious fever in Tamil Nadu, India in 2009-10. The comparative evaluation revealed the higher sensitivity of real-time RT-PCR assay by picking up 4 additional samples with low copy number of template in comparison to conventional RT-PCR. All the real-time positive samples further confirmed by CDC reported TaqMan real-time RT-PCR and quantitative real-time RT-PCR assays for the simultaneous detection of WNV lineage 1 and 2 strains. The quantitation of the viral load samples was done using a standard curve. These findings demonstrated that the assay has the potential usefulness for clinical diagnosis due to detection and quantification of WNV in acute-phase patient serum samples. Copyright © 2014 Elsevier Ltd. All rights reserved.
Yang, Zhifang; Zhang, Zhumin; Penniston, Kristina L.; Binkley, Neil; Tanumihardjo, Sherry A.
2009-01-01
Antioxidant defenses may be compromised in osteoporotic women. Little is known about fruit and vegetable or carotenoid consumption among postmenopausal women. The primary carotenoids in human serum are α- and β-carotene, lycopene, β-cryptoxanthin, lutein, and zeaxanthin. This study investigated the interrelationships among serum carotenoid concentrations, fruit and vegetable intake, and osteoporosis in postmenopausal women (n = 59, 62.7 ± 8.8 y). Bone density was assessed by dual energy x-ray absorptiometry and osteoporosis diagnosis was based upon T-scores. Serum samples (n = 53) and 3-day diet records (n = 49) were analyzed. Logistic regression analyzed differences between carotenoids after adjusting for serum retinol; supplement usage; milk, yogurt, fruit, and vegetable intake; and BMI. Pearson statistics correlated carotenoids with specific fruit or vegetable intake. Serum lycopene concentrations were lower in the osteoporosis group than controls (p = 0.03). β-Cryptoxanthin intake was higher in the osteoporosis group (p = 0.0046). Total fruit and vegetable intakes were correlated with serum lycopene and β-cryptoxanthin (p = 0.03, 0.006, respectively). Serum α-carotene concentration was associated with carrot intake, and zeaxanthin and β-cryptoxanthin with lettuce intake. Carotenoids that may have beneficial skeletal effects are lower in women with osteoporosis. Research is needed to identify potential protective mechanisms or utilization of carotenoids during osteoporosis. PMID:19003732
Piskun, Caroline M.; Muthuswamy, Anantharaman; Huelsmeyer, Michael K.; Thompson, Victoria; Stein, Timothy J.
2011-01-01
Osteosarcoma is an aggressive malignancy of the bone and an increase in serum alkaline phosphatase concentration has clinical prognostic value in both humans and canines. Increased serum alkaline phosphatase concentration at the time of diagnosis has been associated with poorer outcomes for osteosarcoma patients. The biology underlying this negative prognostic factor is poorly understood. Given that activation of the Wnt signaling pathway has been associated with alkaline phosphatase expression in osteoblasts, we hypothesized that the Wnt/β-catenin signaling pathway would be differentially activated in osteosarcoma tissue based on serum ALP status. Archived canine osteosarcoma samples and primary canine osteosarcoma cell lines were used to evaluate the status of Wnt/β-catenin signaling pathway activity through immunohistochemical staining, western immunoblot analyses, quantitative reverse-transcription polymerase chain reaction, and a Wnt-responsive promoter activity assay. We found no significant difference in β-catenin expression or activation between OSA populations differing in serum ALP concentration. Pathway activity was mildly increased in the primary OSA cell line generated from a patient with increased serum ALP compared to the normal serum ALP OSA cell line. Further investigation into the mechanisms underlying differences in serum ALP concentration is necessary to improve our understanding of the biological implications of this negative prognostic indicator. PMID:22022527
Alcorn, S.W.; Pascho, R.J.
2000-01-01
An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.
An enzyme-linked immunosorbent assay for the evaluation of thrombocytopenia induced by heparin.
Howe, S E; Lynch, D M
1985-05-01
Five patients with heparin-associated thrombocytopenia (HAT) were evaluated by platelet aggregation and quantitation of immunoglobulin binding to intact target platelets in both the presence and absence of heparin. These patients developed thrombocytopenia (12,000 to 70,000 platelets/microliter) 7 to 15 days and embolic and hemorrhagic complications 9 to 15 days after the initiation of heparin therapy. Platelet aggregation after the addition of heparin was demonstrated in two of four HAT serum samples, whereas normal serum samples showed no significant platelet aggregation. The five HAT serum samples showed normal to elevated baseline serum platelet-bindable immunoglobulin (SPBIg) with a range of 4.3 to 11.4 fg/platelet (normal less than or equal to 1.0 to 6.5 fg/platelet). When HAT sera were incubated with target platelets and heparin (5 U/ml), the SPBIg increased to 8.5 to 37.5 fg/platelet, a mean increase of 148% in the presence of heparin. Normal and control serum samples (from 10 normal laboratory volunteers, nine patients without thrombocytopenia receiving heparin, nine patients with autoimmune thrombocytopenic purpura, and nine patients with nonimmune thrombocytopenia not receiving heparin) showed only a slight increase in SPBIg of 0 to 2.8 fg/platelet above baseline, a mean increase of 15% after heparin incubation with the serum samples. The measurement of SPBIg of washed platelets incubated with test serum samples in the presence and absence of heparin is potentially a specific and sensitive in vitro test for the diagnosis of HAT and may prove more sensitive than platelet aggregation studies with heparin.
Rezende, Vinícius Marcondes; Rivellis, Ariane Julio; Gomes, Melissa Medrano; Dörr, Felipe Augusto; Novaes, Mafalda Megumi Yoshinaga; Nardinelli, Luciana; Costa, Ariel Lais de Lima; Chamone, Dalton de Alencar Fisher; Bendit, Israel
2013-01-01
Objective The goal of this study was to monitor imatinib mesylate therapeutically in the Tumor Biology Laboratory, Department of Hematology and Hemotherapy, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo (USP). A simple and sensitive method to quantify imatinib and its metabolite (CGP74588) in human serum was developed and fully validated in order to monitor treatment compliance. Methods The method used to quantify these compounds in serum included protein precipitation extraction followed by instrumental analysis using high performance liquid chromatography coupled with mass spectrometry. The method was validated for several parameters, including selectivity, precision, accuracy, recovery and linearity. Results The parameters evaluated during the validation stage exhibited satisfactory results based on the Food and Drug Administration and the Brazilian Health Surveillance Agency (ANVISA) guidelines for validating bioanalytical methods. These parameters also showed a linear correlation greater than 0.99 for the concentration range between 0.500 µg/mL and 10.0 µg/mL and a total analysis time of 13 minutes per sample. This study includes results (imatinib serum concentrations) for 308 samples from patients being treated with imatinib mesylate. Conclusion The method developed in this study was successfully validated and is being efficiently used to measure imatinib concentrations in samples from chronic myeloid leukemia patients to check treatment compliance. The imatinib serum levels of patients achieving a major molecular response were significantly higher than those of patients who did not achieve this result. These results are thus consistent with published reports concerning other populations. PMID:23741187
CJ, Gill; S, Ram; JA, Welsch; L, DeTora; A, Anemona
2014-01-01
The surrogate of protection against invasive meningococcal disease is the presence of serum bactericidal activity (SBA) at a titer ≥4 in an assay using human serum as the complement source (hSBA). However, for various practical and logistical reasons, many meningococcal vaccines in use today were licensed based on a modified SBA assay that used baby rabbit serum as the complement source (rSBA). To assess the strength of correlation between the two assay systems for serogroups A, C, W-135 and Y, we analyzed a subset of samples from adolescent subjects enrolled in a Phase II study of Novartis’ MenACWY-CRM conjugate vaccine vs. an ACWY polysaccharide vaccine; samples were analyzed in parallel using hSBA and rSBA. We compared geometric mean titers (GMTs), calculated Pearson correlation coefficients between paired hSBA and rSBA results, and calculated sensitivity/specificity and likelihood ratios for an rSBA ≥8 or ≥128 for classifying hSBA ≥4, taking hSBA as the ‘gold standard’. Correlations between hSBA and rSBA ranged from 0.46 to 0.78 for serogroup C, but were weaker for serogroups A, W-135 and Y (range -0.15 to 0.57). In post vaccination samples, nearly all subjects had rSBA titers ≥8, though up to 15% remained seronegative by hSBA. In post vaccination settings, rSBA titers at ≥8 or ≥128 was highly sensitive for an hSBA titer ≥4, but non-specific. In conclusion, results generated by rSBA did not accurately classify serostatus according to hSBA for serogroups A, W-135 and Y. PMID:22075087
Harrington, Chris F; McKibbin, Craig; Rahanu, Monika; Langton, David; Taylor, Andrew
2017-05-01
Background Patients with metal-on-metal hip replacements require testing for cobalt and chromium. There may also be a need to test for titanium, which is used in the construction of the femoral stem in total hip replacements. It is not possible to use quadrupole inductively coupled plasma mass spectrometry due to interferences. Methods Titanium was measured using inductively coupled plasma optical emission spectroscopy using the emission line at 336.1 nm and Y (internal standard) at 371.0 nm. Internal quality control materials were prepared for blood and serum and concentrations assigned using a sector field-inductively coupled plasma mass spectrometer. A candidate whole blood certified reference material was also evaluated. Results The method had detection and quantitation limits of 0.6 and 1.9 µg/L, respectively. The respective bias (%) and measurement uncertainty ( U) (k = 2) were 3.3% and 2.0 µg/L (serum) and - 1.0% and 1.4 µg/L (whole blood). The respective repeatability and intermediate precision (%) were 5.1% and 10.9% (serum) and 2.4% and 8.6% (whole blood). The concentration of titanium was determined in patients' samples, serum (median = 2.4 µg/L, n = 897) and whole blood (median = 2.4 µg/L, n = 189). Serum is recommended for monitoring titanium in patients, since the concentration is higher than in whole blood and the matrix less problematic. In hip fluid samples, the concentrations were much higher (mean 58.5 µg/L, median 5.1 µg/L, n = 83). Conclusions A method based on inductively coupled plasma optical emission spectroscopy was developed and validated for measuring titanium in clinical samples.
Yang, Xiaoli; Li, Hongtao; Zhang, Chengdong; Lin, Zhidi; Zhang, Xinhua; Zhang, Youjie; Yu, Yanbao; Liu, Kun; Li, Muyan; Zhang, Yuening; Lv, Wenxin; Xie, Yuanliang; Lu, Zheng; Wu, Chunlei; Teng, Ruobing; Lu, Shaoming; He, Min; Mo, Zengnan
2015-10-01
Prostatitis is one of the most common urological problems afflicting adult men. The etiology and pathogenesis of nonbacterial prostatitis, which accounts for 90-95% of cases, is largely unknown. As serum proteins often indicate the overall pathologic status of patients, we hypothesized that protein biomarkers of prostatitis might be identified by comparing the serum proteomes of patients with and without nonbacterial prostatitis. All untreated samples were collected from subjects attending the Fangchenggang Area Male Health and Examination Survey (FAMHES). We profiled pooled serum samples from four carefully selected groups of patients (n = 10/group) representing the various categories of nonbacterial prostatitis (IIIa, IIIb, and IV) and matched healthy controls using a mass spectrometry-based 4-plex iTRAQ proteomic approach. More than 160 samples were validated by ELISA. Overall, 69 proteins were identified. Among them, 42, 52, and 37 proteins were identified with differential expression in Category IIIa, IIIb, and IV prostatitis, respectively. The 19 common proteins were related to immunity and defense, ion binding, transport, and proteolysis. Two zinc-binding proteins, superoxide dismutase 3 (SOD3), and carbonic anhydrase I (CA1), were significantly higher in all types of prostatitis than in the control. A receiver operating characteristic curve estimated sensitivities of 50.4 and 68.1% and specificities of 92.1 and 83.8% for CA1 and SOD3, respectively, in detecting nonbacterial prostatitis. The serum CA1 concentration was inversely correlated to the zinc concentration in expressed-prostatic secretions. Our findings suggest that SOD3 and CA1 are potential diagnostic markers of nonbacterial prostatitis, although further large-scale studies are required. The molecular profiles of nonbacterial prostatitis pathogenesis may lay a foundation for discovery of new therapies. © 2015 Wiley Periodicals, Inc.
Daly, Elizabeth R; Chan, Benjamin P; Talbot, Elizabeth A; Nassif, Julianne; Bean, Christine; Cavallo, Steffany J; Metcalf, Erin; Simone, Karen; Woolf, Alan D
2018-04-01
Per- and polyfluoroalkyl substances (PFAS) are synthetic chemicals used in manufacturing that resist environmental degradation, can leach into drinking water, and bioaccumulate in tissues. Some studies have shown associations with negative health outcomes. In May 2014, a New Hampshire public drinking water supply was found to be contaminated with PFAS from a former U.S. Air Force base. We established a serum testing program to assess PFAS exposure in the affected community. Serum samples and demographic and exposure information were collected from consenting eligible participants. Samples were tested for PFAS at three analytical laboratories. Geometric means and 95% confidence intervals were calculated and analyzed by age and exposure variables. A total of 1578 individuals provided samples for PFAS testing; >94% were found to have perfluorooctane sulfonic acid (PFOS), perfluorooctanoic acid (PFOA), and perfluorohexane sulfonic acid (PFHxS) detectable in serum. Geometric mean serum concentrations of PFOS, PFOA, and PFHxS were 8.6 μg/L (95% CI:8.3-8.9), 3.1 μg/L (95% CI: 3.0-3.2), and 4.1 μg/L (95% CI: 3.9-4.3), respectively, which were statistically higher than the general U.S. Significant associations were observed between PFAS serum concentrations and age, time spent in the affected community, childcare attendance, and water consumption. PFOS, PFOA, and PFHxS were found in significantly higher levels in the affected population, consistent with PFAS drinking water contamination. Given increased recognition of PFAS contamination in the U.S, a coordinated national response is needed to improve access to biomonitoring and understand health impacts. Copyright © 2018 Elsevier GmbH. All rights reserved.
DNA strand displacement reaction for programmable release of biomolecules.
Ramezani, Hamid; Jed Harrison, D
2015-05-14
Sample cleanup is a major processing step in many analytical assays. Here, we propose an approach to capture-and-release of analytes based on the DNA strand displacement reaction (SDR) and demonstrate its application to a fluoroimmunoassay on beads for a thyroid cancer biomarker, thyroglobulin. The SDR-based cleanup showed no interference from matrix molecules in serum.
Serum markers for type II diabetes mellitus
Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Polpitiya, Ashoka D; Camp, II, David G; Smith, Richard D
2014-03-18
A method for identifying persons with increased risk of developing type 2 diabetes mellitus utilizing selected biomarkers described hereafter either alone or in combination. The present invention allows for broad based, reliable, screening of large population bases and provides other advantages, including the formulation of effective strategies for characterizing, archiving, and contrasting data from multiple sample types under varying conditions.
Altermann, Wolfgang; Schlaf, Gerald; Rothhoff, Anita; Seliger, Barbara
2007-10-01
Previous studies have suggested that the pre-transplant levels of the soluble CD30 molecule (sCD30) represent a non-invasive tool which can be used as a biomarker for the prediction of kidney allograft rejections. In order to evaluate the feasibility of sCD30 for pre-transplantation monitoring the sera of potential kidney recipients (n = 652) were collected four times in a 3 months interval. Serum from healthy blood donors (n = 203) served as controls. The sCD30 concentrations of all samples were determined using a commercially available ELISA. This strategy allowed the detection of possible variations of individual sCD30 levels over time. Heterogeneous sCD30 concentrations were found in the samples obtained from individual putative kidney transplant recipients when quarterly measured over 1 year. Total 95% of serum samples obtained from healthy controls exhibited sCD30 values <30 U/ml, whereas most recipients displayed higher serum levels (>30 U/ml). Total 524 patients (80.4%) constantly exhibited serum concentrations of <100 U/ml during the period investigated, whereas 109 patients (16.7%) showed variations by exceeding the proposed 'cut off' of 100 U/ml for one to three times. The frequency of samples exhibiting sCD30 values >100 U/ml was significantly lower than that previously reported. The high degree of variation does not allow the stratification of patients into high and low immunological risk groups based on a single sCD30 value > 100 U/ml. Due to the heterogeneity of sCD30 levels during time course and the high values of SD, its implementation as a pre-transplant marker cannot be justified to generate special provisions for the organ allocation to patients with single sCD30 values > 100 U/ml.
METHOD FOR MICRORNA ISOLATION FROM CLINICAL SERUM SAMPLES
Li, Yu; Kowdley, Kris V.
2012-01-01
MicroRNAs are a group of intracellular non-coding RNA molecules that have been implicated in a variety of human diseases. Due to their high stability in blood, microRNAs released into circulation could be potentially utilized as non-invasive biomarkers for diagnosis or prognosis. Current microRNA isolation protocols are specifically designed for solid tissues and are impractical for biomarker development utilizing small-volume serum samples on a large scale. Thus, a protocol for microRNA isolation from serum is needed to accommodate these conditions in biomarker development. To establish such a protocol, we developed a simplified approach to normalize sample input by using single synthetic spike-in microRNA. We evaluated three commonly used commercial microRNA isolation kits for the best performance by comparing RNA quality and yield. The manufacturer’s protocol was further modified to improve the microRNA yield from 200 μL of human serum. MicroRNAs isolated from a large set of clinical serum samples were tested on the miRCURY LNA real-time PCR panel and confirmed to be suitable for high-throughput microRNA profiling. In conclusion, we have established a proven method for microRNA isolation from clinical serum samples suitable for microRNA biomarker development. PMID:22982505
Clendenen, Tess V; Rendleman, Justin; Ge, Wenzhen; Koenig, Karen L; Wirgin, Isaac; Currie, Diane; Shore, Roy E; Kirchhoff, Tomas; Zeleniuch-Jacquotte, Anne
2015-01-01
Large epidemiologic studies have the potential to make valuable contributions to the assessment of gene-environment interactions because they prospectively collected detailed exposure data. Some of these studies, however, have only serum or plasma samples as a low quantity source of DNA. We examined whether DNA isolated from serum can be used to reliably and accurately genotype single nucleotide polymorphisms (SNPs) using Sequenom multiplex SNP genotyping technology. We genotyped 81 SNPs using samples from 158 participants in the NYU Women's Health Study. Each participant had DNA from serum and at least one paired DNA sample isolated from a high quality source of DNA, i.e. clots and/or cell precipitates, for comparison. We observed that 60 of the 81 SNPs (74%) had high call frequencies (≥95%) using DNA from serum, only slightly lower than the 85% of SNPs with high call frequencies in DNA from clots or cell precipitates. Of the 57 SNPs with high call frequencies for serum, clot, and cell precipitate DNA, 54 (95%) had highly concordant (>98%) genotype calls across all three sample types. High purity was not a critical factor to successful genotyping. Our results suggest that this multiplex SNP genotyping method can be used reliably on DNA from serum in large-scale epidemiologic studies.
Visualising phase change in a brushite-based calcium phosphate ceramic
Bannerman, A.; Williams, R. L.; Cox, S. C.; Grover, L. M.
2016-01-01
The resorption of brushite-based bone cements has been shown to be highly unpredictable, with strong dependence on a number of conditions. One of the major factors is phase transformation, with change to more stable phases such as hydroxyapatite affecting the rate of resorption. Despite its importance, the analysis of phase transformation has been largely undertaken using methods that only detect crystalline composition and give no information on the spatial distribution of the phases. In this study confocal Raman microscopy was used to map cross-sections of brushite cylinders aged in Phosphate Buffered Saline, Foetal Bovine Serum, Dulbecco’s – Minimum Essential Medium (with and without serum). Image maps showed the importance of ageing medium on the phase composition throughout the ceramic structure. When aged without serum, there was dissolution of the brushite phase concomitant to the deposition of octacalcium phosphate (OCP) around the periphery of the sample. The deposition of OCP was detectable within five days and reduced the rate of brushite dissolution from the material. The use of serum, even at a concentration of 10vol% prevented phase transformation. This paper demonstrates the value of confocal Raman microscopy in monitoring phase change in biocements; it also demonstrates the problems with assessing material degradation in non-serum containing media. PMID:27604149
Visualising phase change in a brushite-based calcium phosphate ceramic
NASA Astrophysics Data System (ADS)
Bannerman, A.; Williams, R. L.; Cox, S. C.; Grover, L. M.
2016-09-01
The resorption of brushite-based bone cements has been shown to be highly unpredictable, with strong dependence on a number of conditions. One of the major factors is phase transformation, with change to more stable phases such as hydroxyapatite affecting the rate of resorption. Despite its importance, the analysis of phase transformation has been largely undertaken using methods that only detect crystalline composition and give no information on the spatial distribution of the phases. In this study confocal Raman microscopy was used to map cross-sections of brushite cylinders aged in Phosphate Buffered Saline, Foetal Bovine Serum, Dulbecco’s - Minimum Essential Medium (with and without serum). Image maps showed the importance of ageing medium on the phase composition throughout the ceramic structure. When aged without serum, there was dissolution of the brushite phase concomitant to the deposition of octacalcium phosphate (OCP) around the periphery of the sample. The deposition of OCP was detectable within five days and reduced the rate of brushite dissolution from the material. The use of serum, even at a concentration of 10vol% prevented phase transformation. This paper demonstrates the value of confocal Raman microscopy in monitoring phase change in biocements; it also demonstrates the problems with assessing material degradation in non-serum containing media.
Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D
2014-04-01
The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.
Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan
2013-01-01
Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.
Garner, Bridget C; Kuroki, Keiichi; Stoker, Aaron M; Cook, Cristi R; Cook, James L
2013-03-01
To identify proteins with differential expression between healthy dogs and dogs with stifle joint osteoarthritis secondary to cranial cruciate ligament (CCL) disease. Serum and synovial fluid samples obtained from dogs with stifle joint osteoarthritis before (n = 10) and after (8) surgery and control dogs without osteoarthritis (9) and archived synovial membrane and articular cartilage samples obtained from dogs with stifle joint osteoarthritis (5) and dogs without arthritis (5). Serum and synovial fluid samples were analyzed via liquid chromatography-tandem mass spectrometry; results were compared against a nonredundant protein database. Expression of complement component 3 in archived tissue samples was determined via immunohistochemical methods. No proteins had significantly different expression between serum samples of control dogs versus those of dogs with stifle joint osteoarthritis. Eleven proteins (complement component 3 precursor, complement factor I precursor, apolipoprotein B-100 precursor, serum paraoxonase and arylesterase 1, zinc-alpha-2-glycoprotein precursor, serum amyloid A, transthyretin precursor, retinol-binding protein 4 precursor, alpha-2-macroglobulin precursor, angiotensinogen precursor, and fibronectin 1 isoform 1 preproprotein) had significantly different expression (> 2.0-fold) between synovial fluid samples obtained before surgery from dogs with stifle joint osteoarthritis versus those obtained from control dogs. Complement component 3 was strongly expressed in all (5/5) synovial membrane samples of dogs with stifle joint osteoarthritis and weakly expressed in 3 of 5 synovial membrane samples of dogs without stifle joint arthritis. Findings suggested that the complement system and proteins involved in lipid and cholesterol metabolism may have a role in stifle joint osteoarthritis, CCL disease, or both.
Castberg, Ingrid; Spigset, Olav
2008-10-01
The aim of this study was to investigate the use of psychotropic medication and therapeutic drug monitoring in a high-security psychiatric unit and to compare the doses and serum concentrations both with the recommended intervals and with the doses and serum concentrations in a control group. One hundred thirty-two patients were admitted in the period from January 2000 to December 2005. All available samples were used when comparing serum concentrations and doses with the recommended ranges. For the comparison of doses and serum concentration-to-dose (C:D) ratios with the control group only 1 sample from each patient was used. A total of 459 analyses of 27 different drugs in samples from 8 women and 73 men were included. The median number of therapeutic drug monitoring analyses per patient was 4 (range 1-29). Thirty-seven of the 81 patients (46%) used 2 or more antipsychotics at the same time. Clozapine, lamotrigine, olanzapine, quetiapine, ziprasidone, and zuclopenthixol were often given in doses above the recommended. The serum levels were frequently above those recommended for clozapine, olanzapine, quetiapine, risperidone, ziprasidone, and zuclopenthixol. The serum levels were significantly higher in the study group than in the control group for clozapine, lamotrigine, quetiapine, and zuclopenthixol. The given dose was significantly higher in the study group than in the control group for clozapine, lamotrigine and zuclopenthixol. The C:D ratio was significantly lower in the study group than in the control group for olanzapine but higher for quetiapine. The non-evidence based practice of high-dose polypharmacy with several antipsychotics is widely used in this unit. The use of higher doses in the study group than in the control group was not due to differences in metabolism or adherence to treatment between the 2 groups. The frequent use of therapeutic drug monitoring did not seem to have a great impact on the prescribed doses.
Suarez-Diez, Maria; Adam, Jonathan; Adamski, Jerzy; Chasapi, Styliani A; Luchinat, Claudio; Peters, Annette; Prehn, Cornelia; Santucci, Claudio; Spyridonidis, Alexandros; Spyroulias, Georgios A; Tenori, Leonardo; Wang-Sattler, Rui; Saccenti, Edoardo
2017-07-07
Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA-MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids.
2017-01-01
Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA–MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids. PMID:28517934
Organic cattle products: Authenticating production origin by analysis of serum mineral content.
Rodríguez-Bermúdez, Ruth; Herrero-Latorre, Carlos; López-Alonso, Marta; Losada, David E; Iglesias, Roberto; Miranda, Marta
2018-10-30
An authentication procedure for differentiating between organic and non-organic cattle production on the basis of analysis of serum samples has been developed. For this purpose, the concentrations of fourteen mineral elements (As, Cd, Co, Cr, Cu, Fe, Hg, I, Mn, Mo, Ni, Pb, Se and Zn) in 522 serum samples from cows (341 from organic farms and 181 from non-organic farms), determined by inductively coupled plasma spectrometry, were used. The chemical information provided by serum analysis was employed to construct different pattern recognition classification models that predict the origin of each sample: organic or non-organic class. Among all classification procedures considered, the best results were obtained with the decision tree C5.0, Random Forest and AdaBoost neural networks, with hit levels close to 90% for both production types. The proposed method, involving analysis of serum samples, provided rapid, accurate in vivo classification of cattle according to organic and non-organic production type. Copyright © 2018 Elsevier Ltd. All rights reserved.
Arain, Salma Aslam; Kazi, Tasneem G; Afridi, Hassan Imran; Abbasi, Abdul Rasool; Panhwar, Abdul Haleem; Naeemullah; Shanker, Bhawani; Arain, Mohammad Balal
2014-12-10
An efficient, innovative preconcentration method, dual-cloud point extraction (d-CPE) has been developed for the extraction and preconcentration of copper (Cu(2+)) in serum samples of different viral hepatitis patients prior to couple with flame atomic absorption spectrometry (FAAS). The d-CPE procedure was based on forming complexes of elemental ions with complexing reagent 1-(2-pyridylazo)-2-naphthol (PAN), and subsequent entrapping the complexes in nonionic surfactant (Triton X-114). Then the surfactant rich phase containing the metal complexes was treated with aqueous nitric acid solution, and metal ions were back extracted into the aqueous phase, as second cloud point extraction stage, and finally determined by flame atomic absorption spectrometry using conventional nebulization. The multivariate strategy was applied to estimate the optimum values of experimental variables for the recovery of Cu(2+) using d-CPE. In optimum experimental conditions, the limit of detection and the enrichment factor were 0.046μgL(-1) and 78, respectively. The validity and accuracy of proposed method were checked by analysis of Cu(2+) in certified sample of serum (CRM) by d-CPE and conventional CPE procedure on same CRM. The proposed method was successfully applied to the determination of Cu(2+) in serum samples of different viral hepatitis patients and healthy controls. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhang, Lei; Zhong, Yuxin; Liu, Xin; Bao, Yan; Zhao, Yunfeng; Wu, Yongning; Cai, Zongwei; Li, Jingguang
2017-09-01
The determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in blood from a non-occupational population is essential for the investigation of adverse health effects from these pollutants. In this study, a sensitive method based on programmable-temperature vaporization with large-volume injection coupled with gas chromatography with high-resolution mass spectrometry was developed to determine these pollutants in 1-2 mL of human serum samples. Various key parameters of programmable-temperature vaporization injector, including vent temperature, vent time, vent flow, transfer temperature and transfer time were optimized by factorial design. The accuracy and precision as well as applicability were assessed by determining polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in calibration standard solutions, standard reference materials and real human serum samples from non-occupational population. The method detection limits of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls were 1.5-9.0 and 0.005-0.02 ng/kg wet weight, respectively. By comparing with typically splitless injection, the application of programmable-temperature vaporization injector could effectively lead to higher detectable rate of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in 1-2 mL of human serum samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Serum levels of interleukin-6 are linked to the severity of the disease caused by Andes Virus.
Angulo, Jenniffer; Martínez-Valdebenito, Constanza; Marco, Claudia; Galeno, Héctor; Villagra, Eliecer; Vera, Lilian; Lagos, Natalia; Becerra, Natalia; Mora, Judith; Bermúdez, Andrea; Díaz, Janepsy; Ferrés, Marcela; López-Lastra, Marcelo
2017-07-01
Andes virus (ANDV) is the etiological agent of hantavirus cardiopulmonary syndrome in Chile. In this study, we evaluated the profile of the pro-inflammatory cytokines IL-1β, IL-12p70, IL-21, TNF-α, IFN-γ, IL-10 and IL-6 in serum samples of ANDV-infected patients at the time of hospitalization. The mean levels of circulating cytokines were determined by a Bead-Based Multiplex assay coupled with Luminex detection technology, in order to compare 43 serum samples of healthy controls and 43 samples of ANDV-infected patients that had been categorized according to the severity of disease. When compared to the controls, no significant differences in IL-1β concentration were observed in ANDV-infected patients (p = 0.9672), whereas levels of IL-12p70 and IL-21 were significantly lower in infected cases (p = <0.0001). Significantly elevated levels of TNF-α, IFN-γ, IL-10, and IL-6 were detected in ANDV-infected individuals (p = <0.0001, 0.0036, <0.0001, <0.0001, respectively). Notably, IL-6 levels were significantly higher (40-fold) in the 22 patients with severe symptoms compared to the 21 individuals with mild symptoms (p = <0.0001). Using multivariate regression models, we show that IL-6 levels has a crude OR of 14.4 (CI: 3.3-63.1). In conclusion, the serum level of IL-6 is a significant predictor of the severity of the clinical outcome of ANDV-induced disease.
Development of optical immunosensors for detection of proteins in serum.
Kyprianou, Dimitris; Chianella, Iva; Guerreiro, Antonio; Piletska, Elena V; Piletsky, Sergey A
2013-01-15
The detection of proteins in biological samples such as blood, serum or plasma by biosensors is very challenging due to the complex nature of the matrix, which contains a high level of many interfering compounds. Here we show the application of a novel polymeric immobilisation matrix that helps in the detection of specific protein analytes in biological samples by surface plasmon resonance (SPR) immunosensors. This polymer matrix contains thioacetal functional groups included in the network, and these groups do not require any further activation in order to react with proteins, making it attractive for sensor fabrication. The protein prostate specific antigen (PSA) was selected as a model target analyte. A sandwich format with two primary antibodies recognising different parts (epitopes) of the analyte was used for the detection of PSA in serum. The efficiency of the reduction of non-specific binding achieved with novel polymer was compared with those of other techniques such as coating of sensor surface with polyethylene glycol (PEG), use of charged hydrophilic aspartic acid and surfactants such as Tween20. The detection limit of the polymer based immunosensor was 0.1 ng ml(-1) for free form PSA (f-PSA) in buffer and 5 ng ml(-1) in 20% serum. This is an improvement compared with similar devices reported on literature, indicating the potential of the immunosensor developed here for the analysis of real samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Vidal, Juan C; Bertolín, Juan R; Bonel, Laura; Asturias, Laura; Arcos-Martínez, M Julia; Castillo, Juan R
2016-06-05
Cocaine is one of the most worldwide used illicit drugs. We report a magnetic particles-based enzyme-linked immunoassay (mpEIA) method for the rapid and sensitive determination of cocaine (COC) in saliva, urine and serum samples. Under optimized conditions, the limits of detections were 0.09ngmL(-1) (urine), 0.15ngmL(-1) (saliva), and 0.06ngmL(-1) COC (human serum). Sensitivities were in the range EC50=0.6-2.5ngmL(-1) COC. The cross-reactivity with the principal metabolite benzoylecgonine (BZE) was only 1.6%. Recovering percentages of doped samples (0, 10, 50, and 100ngmL(-1) of COC) ranged from about 86-111%. Some advantages of the developed mpEIA over conventional ELISA kits are faster incubations, improved reproducibility, and consumption of lower amounts of antibody and enzyme conjugates due to the use of magnetic beads. The reported method was validated following the guidelines on bioanalytical methods of the European Medicines Agency (2011). Unmetabolized COC detection has a great interest in pharmacological, pharmacokinetics, and toxicokinetics studies, and can be used to detect a very recent COC use (1-6h). Copyright © 2016 Elsevier B.V. All rights reserved.
Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon
2017-11-30
The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The recovery of serum miRNA dry-spotted on FTA Elute cards by direct elution with water at high temperature was poor. However, serum miRNAs dry-spotted on the cards were isolated with about 40% yield when using QIAzol lysis reagent and recovery was improved remarkably (>80%) upon extraction from cards pre-treated with trehalose. miRNAs stored on the cards remained stable at room temperature and can be kept for prolonged periods. Furthermore, miRNAs could be similarly recovered from serum exosomes dry-spotted on the cards. Importantly, when using sera from gastric cancer (GC) patients, the miRNAs were efficiently recovered from trehalose pre-treated cards without affecting their representation. Collectively, we have demonstrated the potential of FTA Elute cards to archive serum and serum exosomal miRNAs, making it useful for biomarker discovery and diagnostics.
Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuettler, J.; White, P.F.
Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and upmore » to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.« less
Xu, Weifeng; Jiang, Hao; Titsch, Craig; Haulenbeek, Jonathan R; Pillutla, Renuka C; Aubry, Anne-Françoise; DeSilva, Binodh S; Arnold, Mark E; Zeng, Jianing; Dodge, Robert W
2015-01-01
Biological therapeutics can induce an undesirable immune response resulting in the formation of anti-drug antibodies (ADA), including neutralizing antibodies (NAbs). Functional (usually cell-based) NAb assays are preferred to determine NAb presence in patient serum, but are often subject to interferences from numerous serum factors, such as growth factors and disease-related cytokines. Many functional cell-based NAb assays are essentially drug concentration assays that imply the presence of NAbs by the detection of small changes in functional drug concentration. Any drug contained in the test sample will increase the total amount of drug in the assay, thus reducing the sensitivity of NAb detection. Biotin-drug Extraction with Acid Dissociation (BEAD) has been successfully applied to extract ADA, thereby removing drug and other interfering factors from human serum samples. However, to date there has been no report to estimate the residual drug level after BEAD treatment when the drug itself is a human monoclonal antibody; mainly due to the limitation of traditional ligand-binding assays. Here we describe a universal BEAD optimization procedure for human monoclonal antibody (mAb) drugs by using a LC-MS/MS method to simultaneously measure drug (a mutant human IgG4), NAb positive control (a mouse IgG), and endogenous human IgGs as an indicator of nonspecific carry-over in the BEAD eluate. This is the first report demonstrating that residual human mAb drug level in clinical sample can be measured after BEAD pre-treatment, which is critical for further BEAD procedure optimization and downstream immunogenicity testing. Copyright © 2014 Elsevier B.V. All rights reserved.
Wibom, Carl; Späth, Florentin; Dahlin, Anna M; Langseth, Hilde; Hovig, Eivind; Rajaraman, Preetha; Johannesen, Tom Børge; Andersson, Ulrika; Melin, Beatrice
2015-05-01
Although glioma etiology is poorly understood in general, growing evidence indicates a genetic component. Four large genome-wide association studies (GWAS) have linked common genetic variants with an increased glioma risk. However, to date, these studies are based largely on a case-control design, where cases have been recruited at the time of or after diagnosis. They may therefore suffer from a degree of survival bias, introduced when rapidly fatal cases are not included. To confirm glioma risk variants in a prospective setting, we have analyzed 11 previously identified risk variants in a set of prediagnostic serum samples with 598 cases and 595 matched controls. Serum samples were acquired from The Janus Serum Bank, a Norwegian population-based biobank reserved for cancer research. We confirmed the association with glioma risk for variants within five genomic regions: 8q24.21 (CCDC26), 9p21.3 (CDKN2B-AS1), 11q23.3 (PHLDB1), 17p13.1 (TP53), and 20q13.33 (RTEL1). However, previously identified risk variants within the 7p11.2 (EGFR) region were not confirmed by this study. Our results indicate that the risk variants that were confirmed by this study are truly associated with glioma risk and may, consequently, affect gliomagenesis. Though the lack of positive confirmation of EGFR risk variants may be attributable to relatively limited statistical power, it nevertheless raises the question whether they truly are risk variants or markers for glioma prognosis. Our findings indicate the need for further studies to clarify the role of glioma risk loci with respect to prolonged survival versus etiology. ©2015 American Association for Cancer Research.
Quantitating Iron in Serum Ferritin by Use of ICP-MS
NASA Technical Reports Server (NTRS)
Smith, Scott M.; Gillman, Patricia L.
2003-01-01
A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid to extract its iron content. Finally, a micronebulizer is used to inject the sample of the product of the digestion into the ICPMS for analysis of its iron content. The sensitivity of the ICP-MS is high enough to enable it to characterize samples smaller than those required in the prior method (samples can be 0.15 to 0.60 mL).
Thelin, Eric Peter; Zeiler, Frederick Adam; Ercole, Ari; Mondello, Stefania; Büki, András; Bellander, Bo-Michael; Helmy, Adel; Menon, David K; Nelson, David W
2017-01-01
The proteins S100B, neuron-specific enolase (NSE), glial fibrillary acidic protein (GFAP), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), and neurofilament light (NF-L) have been serially sampled in serum of patients suffering from traumatic brain injury (TBI) in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term "effective half-life" ( t 1/2 ) in order to describe the "fall" rate in serum. Through searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations. Following screening (10,389 papers), n = 122 papers were included. The proteins S100B ( n = 66) and NSE ( n = 27) were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t 1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1-2 h) though possibly of non-cerebral origin. In contrast, the t 1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP ( n = 18) appears to have t 1/2 of about 24-48 h in severe TBI. The protein UCH-L1 ( n = 9) presents a t 1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L ( n = 2) only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use. Serial sampling of brain-specific proteins in serum reveals different temporal trajectories that should be acknowledged. Proteins with shorter serum availability, like S100B, may be superior to proteins such as NF-L in detection of secondary harmful events when monitoring patients with TBI.
Huppertz, Laura M; Kneisel, Stefan; Auwärter, Volker; Kempf, Jürgen
2014-02-01
Considering the vast variety of synthetic cannabinoids and herbal mixtures - commonly known as 'Spice' or 'K2' - on the market and the resulting increase of severe intoxications related to their consumption, there is a need in clinical and forensic toxicology for comprehensive up-to-date screening methods. The focus of this project aimed at developing and implementing an automated screening procedure for the detection of synthetic cannabinoids in serum using a liquid chromatography-ion trap-MS (LC-MS(n)) system and a spectra library-based approach, currently including 46 synthetic cannabinoids and 8 isotope labelled analogues. In the process of method development, a high-temperature ESI source (IonBooster(TM), Bruker Daltonik) and its effects on the ionization efficiency of the investigated synthetic cannabinoids were evaluated and compared to a conventional ESI source. Despite their structural diversity, all investigated synthetic cannabinoids benefitted from high-temperature ionization by showing remarkably higher MS intensities compared to conventional ESI. The employed search algorithm matches retention time, MS and MS(2)/MS(3) spectra. With the utilization of the ionBooster source, limits for the automated detection comparable to cut-off values of routine MRM methods were achieved for the majority of analytes. Even compounds not identified when using a conventional ESI source were detected using the ionBooster-source. LODs in serum range from 0.1 ng/ml to 0.5 ng/ml. The use of parent compounds as analytical targets offers the possibility of instantly adding new emerging compounds to the library and immediately applying the updated method to serum samples, allowing the rapid adaptation of the screening method to ongoing forensic or clinical requirements. The presented approach can also be applied to other specimens, such as oral fluid or hair, and herbal mixtures and was successfully applied to authentic serum samples. Quantitative MRM results of samples with analyte concentrations above the determined LOD were confirmed as positive findings by the presented method. Copyright © 2014 John Wiley & Sons, Ltd.
Serum fibroblast growth factor 23 concentrations in dogs with chronic kidney disease.
Dittmer, Keren E; Perera, Kalyani C; Elder, Peter A
2017-10-01
The aim of this study was to determine if serum fibroblast growth factor (FGF23) concentrations were increased in dogs with chronic kidney disease (CKD). Serum samples submitted to a commercial laboratory were collected over a 15-month period, 14 samples were from dogs with a history of polyuria/polydipsia, azotaemia and low urine specific gravity, 20 samples were from non-azotaemic dogs. Serum FGF23, parathyroid hormone, total calcium and phosphorus, urea and creatinine were measured. Mann-Whitney test was used to determine differences between non-azotaemic and CKD groups; a one-way ANOVA with Tukey pairwise comparisons was used to determine any differences between International Renal Interest Society stages; and regression models were used to determine predictors of International Renal Interest Society stage, serum phosphorus and FGF23 concentrations. The median serum FGF23 concentration of dogs with CKD was 5194.6pg/mL, which was significantly greater (P<0.001) than the median serum FGF23 concentration of non-azotaemic dogs (259.2pg/mL). Log serum FGF23 and age were significantly associated with IRIS stage (P=0.027 and P=0.032 respectively), while log serum phosphorus concentration (P<0.001) was significantly associated with log serum FGF23 concentration. In summary, serum FGF23 concentration is increased in dogs with CKD, and is associated with serum phosphorus concentration. This phosphatonin pathway may be a useful target for the development of future treatments to control plasma phosphorus concentrations in chronic kidney disease. Copyright © 2017 Elsevier Ltd. All rights reserved.
Spectrofluorimetric determination of cefixime using terbium-danofloxacin probe
Manzoori, Jamshid L.; Amjadi, Mohammad; Soltani, Naser; Jouyban, Abolghasem
2014-01-01
Objective(s): Cefixime (Cfx), is a semi-synthetic third-generation oral cephalosporin antibiotic that is prescribed for the treatment of susceptible infections. There are some procedures for the determination of Cfx in pharmaceutical formulations and biological samples. Herein a spectrofluorimetric method was proposed for Cfx determination based on the fluorescence quenching of terbium-danofloxacin (Tb3+-Dano) in the presence of Cfx. Materials and Methods: Cfx was detected based on fluorescence quenching of terbium-danofloxacin (Tb3+-Dano) in the presence of Cfx with maximum excitation and emission wavelengths at 347 nm and 545 nm, respectively. The quenched fluorescence intensity of Tb3+- Dano system is proportional to the concentration of Cfx. The optimum conditions for the determination of Cfx were studied. Results: The maximum response was achieved under optimum conditions of [Tris buffer]= 0.008 mol/l (pH 6.5), [Tb3+]=1×10-4 mol/l and [Dano]=1×10-4 mol/l. The developed method was evaluated in terms of accuracy, precision and limit of detection. The linear concentration ranges for quantification of Cfx were 8.8×10-8-8.8×10-7 mol/l and 1.1×10-7-8.8×10-7 mol/l in standard and human serum samples with the detection limits (S/N=3) of 2.8×10-8 mol/l and 3.9×10-8 mol/l, respectively. The Cfx was determined in pharmaceutical tablets and spiked serum samples and the results were satisfactory. Conclusion: This method is simple, practical and relatively interference-free for determination of Cfx in pharmaceutical tablets and serum samples. PMID:24904718
NASA Astrophysics Data System (ADS)
Nagaraja, Padmarajaiah; Avinash, Krishnegowda; Shivakumar, Anantharaman; Krishna, Honnur
Glomerular filtration rate (GFR), the marker of chronic kidney disease can be analyzed by the concentration of cystatin C or creatinine and its clearance in human urine and serum samples. The determination of cystatin C alone as an indicator of GFR does not provide high accuracy, and is more expensive, thus measurement of creatinine has an important role in estimating GFR. We have made an attempt to quantify creatinine based on its pseudoenzyme activity of creatinine in the presence of copper. Creatinine in the presence of copper oxidizes paraphenylenediamine dihydrochloride (PPDD) which couples with dimethylamino benzoicacid (DMAB) giving green colored chromogenic product with maximum absorbance at 710 nm. Kinetic parameters relating this reaction were evaluated. Analytical curves of creatinine by fixed time and rate methods were linear at 8.8-530 μmol L-1 and 0.221-2.65 mmol L-1, respectively. Recovery of creatinine varied from 97.8 to 107.8%. Limit of detection and limit of quantification were 2.55 and 8.52 μmol L-1 respectively whereas Sandell's sensitivity and molar absorption coefficient values were 0.0407 μg cm-2 and 0.1427 × 104 L mol-1 cm-1 respectively. Precision studies showed that within day imprecision was 0.745-1.26% and day-to-day imprecision was 1.55-3.65%. The proposed method was applied to human urine and serum samples and results were validated in accordance with modified Jaffe's procedure. Wide linearity ranges with good recovery, less tolerance from excipients and application of the method to serum and urine samples are the claims which ascertain much advantage to this method.
Böttger, Roland; Hoffmann, Ralf; Knappe, Daniel
2017-01-01
Proteolytic degradation of peptide-based drugs is often considered as major weakness limiting systemic therapeutic applications. Therefore, huge efforts are typically devoted to stabilize sequences against proteases present in serum or plasma, obtained as supernatants after complete blood coagulation or centrifugation of blood supplemented with anticoagulants, respectively. Plasma and serum are reproducibly obtained from animals and humans allowing consistent for clinical analyses and research applications. However, the spectrum of active or activated proteases appears to vary depending on the activation of proteases and cofactors during coagulation (serum) or inhibition of such enzymes by anticoagulants (plasma), such as EDTA (metallo- and Ca2+-dependent proteases) and heparin (e.g. thrombin, factor Xa). Here, we studied the presumed effects on peptide degradation by taking blood via cardiac puncture of CD-1 mice using a syringe containing a peptide solution. Due to absence of coagulation activators (e.g. glass surfaces and damaged cells), visible blood clotting was prevented allowing to study peptide degradation for one hour. The remaining peptide was quantified and the degradation products were identified using mass spectrometry. When the degradation rates (half-life times) were compared to serum derived freshly from the same animal and commercial serum and plasma samples, peptides of three different families showed indeed considerably different stabilities. Generally, peptides were faster degraded in serum than in plasma, but surprisingly all peptides were more stable in fresh blood and the order of degradation rates among the peptides varied among the six different incubation experiments. This indicates, that proteolytic degradation of peptide-based therapeutics may often be misleading stimulating efforts to stabilize peptides at degradation sites relevant only in vitro, i.e., for serum or plasma stability assays, but of lower importance in vivo.
Self-reported smoking habits and serum cotinine levels in women with placental abruption.
Tikkanen, Minna; Surcel, Heljä-Marja; Bloigu, Aini; Nuutila, Mika; Ylikorkala, Olavi; Hiilesmaa, Vilho; Paavonen, Jorma
2010-12-01
smoking is an important risk factor for placental abruption with strong dose-dependency. Pregnant smokers often underreport tobacco use which can be objectively assessed by measuring serum cotinine levels. We examined the accuracy between self-reported smoking habits and early pregnancy serum cotinine levels in women with or without placental abruption. retrospective case-control study. university Hospital. a total of 175 women with placental abruption and 370 control women. serum samples collected during the first trimester were analyzed for serum cotinine levels. Cotinine concentration over 15 ng/ml was considered as the cutoff indicating active smoking. Smoking habits of the women and their partners were recorded at the same visit. placental abruption. of the cases of women with placental abruption, 27.4% reported smoking compared with 14.3% of the controls (p < 0.001). Based on serum cotinine levels, 30.3% of the case women and 17.6% of the control women were considered smokers (p = 0.003). Serum cotinine levels among smokers were higher in the abruption group than in the control group (median 229.5 ng/ml (interquartile range 169.8-418.1) vs. 153.5 ng/ml (56.6-241.4), p = 0.002). Self-reported number of cigarettes smoked daily correlated well with the cotinine levels (r = 0.68, p < 0.001). Of the women reporting as nonsmokers, approximately 7% were considered smokers based on cotinine testing. pregnant women with subsequent placental abruption are heavier smokers than pregnant control women. Self-reported smoking habits correlate well with serum cotinine levels in Finland. Therefore, self-reported smoking can be considered as a risk marker for placental abruption.
Hisamatsu, Takashi; Miura, Katsuyuki; Fujiyoshi, Akira; Kadota, Aya; Miyagawa, Naoko; Satoh, Atsushi; Zaid, Maryam; Yamamoto, Takashi; Horie, Minoru; Ueshima, Hirotsugu
2018-06-01
Calcific aortic valve disease (CAVD) is the most common valve disease. Although micronutrients are known to contribute to cardiovascular disease, the relationship with CAVD remains poorly evaluated. We examined the association of serum levels of magnesium, phosphorus, and calcium with prevalence, incidence, and progression of aortic valve calcification (AVC). We conducted a prospective study in a population-based sample of Japanese men aged 40-79 years without known cardiovascular disease and chronic kidney disease at baseline, and quantified AVC from serial computed tomographic images with the Agatston method. Of 938 participants at baseline (mean age, 63.7 ± 9.9 years), AVC prevalence was observed in 173 (18.4%). Of 596 participants without baseline AVC at follow-up (median duration, 5.1 years), AVC incidence was observed in 138 (23.2%). After adjustment for demographics, behaviors and cardiovascular risk factors, relative risks (95% confidence intervals) in the highest versus lowest categories of serum magnesium, phosphorus, and calcium were 0.62 (0.44-0.86), 1.45 (1.02-2.04), and 1.43 (0.95-2.15), respectively, for AVC prevalence and 0.62 (0.42-0.92), 1.93 (1.28-2.91), and 1.09 (0.77-1.55), respectively, for AVC incidence. Their linear trends of serum magnesium and phosphorus were also all statistically significant. Of 131 participants with baseline AVC, there was no association of any serum micronutrients with AVC progression. Serum magnesium was inversely associated, while serum phosphorus was positively associated with AVC prevalence and incidence, suggesting that these serum micronutrients may be potential candidates for risk prediction or prevention of CAVD, and warranting further studies. Copyright © 2018 Elsevier B.V. All rights reserved.
Heterophile antibody interference in qualitative urine/serum hCG devices: Case report.
Patel, Khushbu K; Gronowski, Ann M
2016-06-01
This case report investigates the origin of a false positive result on a serum qualitative human chorionic gonadotropin (hCG) device. A 46-year-old woman diagnosed with chronic myeloid leukemia presented with nausea and vomiting. A qualitative serum hCG test was interpreted as positive; however, a quantitative serum hCG test was negative (<5IU/L). To further investigate this discrepancy, the sample was pretreated with heterophilic blocking reagent (HBR). Additionally, the sample was tested on other qualitative hCG devices composed of antibodies from different animal sources. Blocking reagent from an automated quantitative immunoassay was also tested for its ability to inhibit the heterophile antibody interference. The qualitative test result was negative after pretreatment with heterophilic blocking reagent. Other devices composed of antibodies from different animal sources also demonstrated mixed results with the patient's sample. Blocking reagent obtained from the automated quantitative assay inhibited the heterophile antibody interference in the patient's sample. This case demonstrates that positive serum point-of-care hCG results should be interpreted with caution and confirmed with a quantitative serum hCG immunoassay when clinical suspicion is raised. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum.
Dussart, Philippe; Labeau, Bhety; Lagathu, Gisèle; Louis, Philippe; Nunes, Marcio R T; Rodrigues, Sueli G; Storck-Herrmann, Cécile; Cesaire, Raymond; Morvan, Jacques; Flamand, Marie; Baril, Laurence
2006-11-01
We evaluated a one-step sandwich-format microplate enzyme immunoassay for detecting dengue virus NS1 antigen (Ag) in human serum by use of Platelia Dengue NS1 Ag kits (Bio-Rad Laboratories, Marnes La Coquette, France). We collected 299 serum samples from patients with dengue disease and 50 serum samples from patients not infected with dengue virus. For the 239 serum samples from patients with acute infections testing positive by reverse transcription-PCR and/or virus isolation for one of the four dengue virus serotypes, the sensitivity of the Platelia Dengue NS1 Ag kit was 88.7% (95% confidence interval, 84.0% to 92.4%). None of the serum samples from patients not infected with dengue virus tested positive with the Platelia Dengue NS1 Ag kit. A diagnostic strategy combining the Platelia Dengue NS1 Ag test for acute-phase sera and immunoglobulin M capture enzyme-linked immunosorbent assay for early-convalescent-phase sera increased sensitivity only from 88.7% to 91.9%. Thus, NS1 antigen detection with the Platelia Dengue NS1 Ag kit could be used for first-line testing for acute dengue virus infection in clinical diagnostic laboratories.
Cells and biofluids analyzed in aqueous environment by infrared spectroscopy
NASA Astrophysics Data System (ADS)
Naumann, D.; Lasch, P.; Fabian, H.
2006-02-01
Infrared transmission/absorption measurements of cells and biofluids in water are restricted to very short optical pathlengths. When the amide I and amide II bands of protein constituents have to be analysed, path-lengths of less than 8 μm are necessary. Infrared spectra of cancer cells were collected from physiological buffer solutions utilizing custom-made mid-infrared compatible IR-cuvettes. The technology permitted to obtain cell-type specific spectral signatures and probe biochemical changes induced by varying temperatures or cell-drug interaction. Optical path-lengths of 8-30 μm were used on a set of microbial test strains to evaluate, whether the methodology can also be used to discriminate and identify micro-organisms. A semi-automatic methodology was developed for the analysis of liquid serum samples, which combines simple sample handling with high sample throughput and extreme measurement reproducibility. The applicability of this infrared technology to the analysis of liquid serum samples from cattle and human beings suffering from various acute viral or bacterial infections was explored testing the interrelationship between α-helical and β-sheet specific spectral signatures in the amide I band contour and total albumin and globulin content in serum. The technical details, advantages, and limitations of the new technology are described in the context of developing a routine, IR-based biodiagnostic technique for biofluids and biological cells.
Parsons, Nola J; Schaefer, Adam M; van der Spuy, Stephen D; Gous, Tertius A
2015-03-25
There are few publications on the clinical haematology and biochemistry of African penguins (Spheniscus demersus) and these are based on captive populations. Baseline haematology and serum biochemistry parameters were analysed from 108 blood samples from wild, adult African penguins. Samples were collected from the breeding range of the African penguin in South Africa and the results were compared between breeding region and sex. The haematological parameters that were measured were: haematocrit, haemoglobin, red cell count and white cell count. The biochemical parameters that were measured were: sodium, potassium, chloride, calcium, inorganic phosphate, creatinine, cholesterol, serum glucose, uric acid, bile acid, total serum protein, albumin, aspartate transaminase and creatine kinase. All samples were serologically negative for selected avian diseases and no blood parasites were detected. No haemolysis was present in any of the analysed samples. Male African penguins were larger and heavier than females, with higher haematocrit, haemoglobin and red cell count values, but lower calcium and phosphate values. African penguins in the Eastern Cape were heavier than those in the Western Cape, with lower white cell count and globulin values and a higher albumin/globulin ratio, possibly indicating that birds are in a poorer condition in the Western Cape. Results were also compared between multiple penguin species and with African penguins in captivity. These values for healthy, wild, adult penguins can be used for future health and disease assessments.
Yamane, Itsuro; Ishizeki, Sayoko; Yamazaki, Hisanori
2015-05-01
Pseudorabies virus (PRV) is endemic in some regions of Japan. We investigated the effects of PRV infection status on herd productivity. Serum samples were obtained from 48 swine herds in Japan. Within each herd, three serum samples were obtained from growing pigs at four different ages, as well as from sows in low and high parity groups. Sera were tested for antibodies against wild-type PRV via competitive ELISA. Herds were classified into PRV positive and negative groups based on serological results. Herds infected with PRV exhibited postweaning mortalities (6.84%) that were significantly (P=0.0018) higher than those in unaffected herds (4.73%). Because of the reduced productivity in PRV positive herds, the current PRV eradication program must be strengthened.
Garca, Mehmet Fatih; Demir, Halit; Turan, Mahfuz; Bozan, Nazım; Kozan, Ahmet; Belli, Şeyda Bayel; Arslan, Ayşe; Cankaya, Hakan
2014-06-01
To emphasize the effectiveness of adenosine deaminase (ADA) enzyme, which has important roles in the differentiation of lymphoid cells, and oxidative stress in patients with chronic tonsillitis. Serum and tissue samples were obtained from 25 patients who underwent tonsillectomy due to recurrent episodes of acute tonsillitis. In the control group, which also had 25 subjects, only serum samples were taken as obtaining tissue samples would not have been ethically appropriate. ADA enzyme activity, catalase (CAT), carbonic anhydrase (CA), nitric oxide (NO) and malondialdehyde (MDA) were measured in the serum and tissue samples of patients and control group subjects. The serum values of both groups were compared. In addition, the tissue and serum values of patients were compared. Serum ADA activity and the oxidant enzymes MDA and NO values of the patient group were significantly higher than those of the control group (p < 0.001), the antioxidant enzymes CA and CAT values of the patient group were significantly lower than those of the control group (p < 0.001). In addition, while CA, CAT and NO enzyme levels were found to be significantly higher in the tonsil tissue of the patient group when compared to serum levels (p < 0.05), there was no difference between tissue and serum MDA and ADA activity (p > 0.05). Elevated ADA activity may be effective in the pathogenesis of chronic tonsillitis both by impairing tissue structure and contributing to SOR formation.
Sá e Silva, Mariana; Swayne, David E
2012-09-01
Surveillance for low pathogenicity avian influenza virus (LPAIV) infections has primarily relied on labor-intensive collection and serological testing of serum, but for many poultry diseases, easier-to-collect yolk samples have replaced serum for surveillance testing. A time-course LPAIV infection study in layers was performed to evaluate the utility of antibody detection in serum vs. egg yolk samples. Layers inoculated with the LPAIV A/Bobwhite Quail/Pennsylvania/20304/98 (H7N2) were tested for antibody levels in the serum and egg yolk by using the agar gel immunodiffusion test (AGID), hemagglutination-inhibition test (HI), and a commercially available enzyme-linked immunosorbent assay (ELISA). Anti-influenza specific antibodies were detected in the serum as early as 7 days postinoculation (DPI), and the majority of the hens remained positive until 42 DPI. Antibodies in the egg yolk were first detected by AGID at 7 DPI, which was also the first day of detection in serum. However, the majority of the eggs were positive by all techniques at 11 DPI and remained positive until 42 DPI, at which time the number of AGID+ and HI+ samples declined slightly as compared to ELISA+ samples. These results suggest that egg yolk can be an alternative to serum for flock serological surveillance against LPAIV infections, and the three methods (AGID, HI, and ELISA) will give similar results for first 42 days after infection, although AGID may give earlier positive response.
Serum levels of perfluoroalkyl compounds in human maternal and umbilical cord blood samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monroy, Rocio; Morrison, Katherine; Teo, Koon
2008-09-15
Perfluoroalkyl compounds (PFCs) are end-stage metabolic products from industrial flourochemicals used in the manufacture of plastics, textiles, and electronics that are widely distributed in the environment. The objective of the present study was to quantify exposure to perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), perfluorodecanoic acid (PFDeA), perfluorohexane sulfonate (PFHxS), perfluoroheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA) in serum samples collected from pregnant women and the umbilical cord at delivery. Pregnant women (n=101) presenting for second trimester ultrasound were recruited and PFC residue levels were quantified in maternal serum at 24-28 weeks of pregnancy, at delivery, and in umbilical cord blood (UCB;more » n=105) by liquid chromatography-mass spectrometry. Paired t-test and multiple regression analysis were performed to determine the relationship between the concentrations of each analyte at different sample collection time points. PFOA and PFOS were detectable in all serum samples analyzed including the UCB. PFOS serum levels (mean{+-}S.D.) were significantly higher (p<0.001) in second trimester maternal serum (18.1{+-}10.9 ng/mL) than maternal serum levels at delivery (16.2{+-}10.4 ng/mL), which were higher than the levels found in UCB (7.3{+-}5.8 ng/mL; p<0.001). PFHxS was quantifiable in 46/101 (45.5%) maternal and 21/105 (20%) UCB samples with a mean concentration of 4.05{+-}12.3 and 5.05{+-}12.9 ng/mL, respectively. There was no association between serum PFCs at any time point studied and birth weight. Taken together our data demonstrate that although there is widespread exposure to PFCs during development, these exposures do not affect birth weight.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kronewitter, Scott R.; Marginean, Ioan; Cox, Jonathan T.
The N-glycan diversity of human serum glycoproteins, i.e. the human blood serum N-glycome, is complex due to the range of glycan structures potentially synthesizable by human glycosylation enzymes. The reported glycome, however, is limited by methods of sample preparation, available analytical platforms, e.g., based upon electrospray ionization-mass spectrometry (ESI-MS), and software tools for data analysis. In this report, several improvements have been implemented in sample preparation and analysis to extend ESI-MS glycan characterization and to provide an improved view of glycan diversity. Sample preparation improvements include acidified, microwave-accelerated, PNGase F N-glycan release, and sodium borohydride reduction were optimized to improvemore » quantitative yields and conserve the number of glycoforms detected. Two-stage desalting (during solid phase extraction and on the analytical column) increased the sensitivity by reducing analyte signal division between multiple reducing-end-forms or cation adducts. On-line separations were improved by using extended length graphitized carbon columns and adding TFA as an acid modifier to a formic acid/reversed phase gradient which provides additional resolving power and significantly improved desorption of both large and heavily sialylated glycans. To improve MS sensitivity and provide gentler ionization conditions at the source-MS interface, subambient pressure ionization with nanoelectrospray (SPIN) has been utilized. When method improvements are combined together with the Glycomics Quintavariate Informed Quantification (GlyQ-IQ) recently described1 these technologies demonstrate the ability to significantly extend glycan detection sensitivity and provide expanded glycan coverage. We demonstrate application of these advances in the context of the human serum glycome, and for which our initial observations include detection of a new class of heavily sialylated N-glycans, including polysialylated N-glycans.« less
Mahdavi, M R; Makhlough, A; Kosaryan, M; Roshan, P
2011-10-01
Anemia is a common complication in uremic patients. Erythropoietin therapy is prescribed in these cases; however, this treatment is not successful in iron deficient patients. Ferritin-based diagnosis of iron deficiency in these patients is a challenging task, as serum ferritin level may be high due to chronic inflammation and mask iron deficiency. In the current study we evaluated the credibility of another indicator of body iron supply, serum transferrin receptor, in hemodialysis patients in two University-based Hospitals in North of Iran. In a cross-sectional study, 53 hemodialysis patients with a mean age of 56 +/- 18.7 years and 30 persons with iron deficiency and normal renal function with a mean age of 20.1 +/- 14.4 years were examined. All hemodialysis patients were on hemodialysis 2-3 times per week for 3-4 hours. All cases were examined for blood hemoglobin content, serum iron, CRP, serum ferritin and serum transferrin receptor levels. The reference ranges introduced by manufacturers were considered as standard ranges for analysis of the results. Using one sample T-test and Fisher's exact test, data were analyzed. p<0.05 was considered as significant. Hemodialysis patients had blood hemoglobin content below normal range (p<0.05 for men, p<0.001 for women) and CRP levels above normal range (p<0.001). In hemodialysis patients, serum ferritin level was significantly higher than control group (p<0.001), whilst serum transferrin receptor levels in the two groups were not significantly different (p=0.69), and both were above defined normal upper limit (p<0.001 for iron deficient patients; p<0.05 for hemodialysis patients). This study showed measurement of serum ferritin in the presence of chronic inflammation induced by renal failure cannot be a credible indicator of body iron supply, while under this certain condition serum transferrin receptor can more appropriately reflect the amount of body iron supply.
Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya
2015-01-01
The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.
Serum PCB levels and congener profiles among US construction workers
Herrick, Robert F; Meeker, John D; Hauser, Russ; Altshul, Larisa; Weymouth, George A
2007-01-01
Background The presence of PCB in caulking (sealant) material found in masonry buildings has been well-documented in several countries. A recent investigation of 24 buildings in the greater Boston area found that 8 buildings had high PCB levels in caulking materials used around window frames and in joints between masonry blocks. Workers removing caulking material have been shown to have elevated serum PCB levels. Methods This project compared serum PCB levels among male workers who installed and/or removed PCB-containing caulking material from buildings in the greater Boston area with reference serum PCB levels from 358 men from the same area. Serum PCB levels were measured in the same laboratory by liquid-liquid extraction, column chromatography clean-up and dual capillary column GC/microECD analysis. Results When the congener profiles were compared between the reference population and the construction workers, the serum levels of the more volatile, lighter PCBs (di-, tri-and tetrachloro, sum of IUPAC# 6–74) were substantially higher among the construction workers. One of the youngest workers had the lowest total serum PCB levels (sum of 57 congeners) of all 6 workers, but the contribution of more volatile (less chlorinated) PCB congeners (#16, 26,28,33,74,66, and 60) was markedly higher than in other 5 workers and reference men. Only this worker was working on a job that involved removing PCB caulking at the time of the blood sampling. Conclusion While the results of this pilot study are based upon small numbers (6 construction workers who handled PCB caulking), the serum PCB levels among the construction workers exceed the referents. Comparison of the congener profiles suggests that there are substantial differences between the construction workers and the general population samples. These differences, and the similarities of profiles among the construction workers strongly suggest that occupational contact with caulking material can be a major source of PCB exposure for construction workers. PMID:17764566
Large-scale serum protein biomarker discovery in Duchenne muscular dystrophy.
Hathout, Yetrib; Brody, Edward; Clemens, Paula R; Cripe, Linda; DeLisle, Robert Kirk; Furlong, Pat; Gordish-Dressman, Heather; Hache, Lauren; Henricson, Erik; Hoffman, Eric P; Kobayashi, Yvonne Monique; Lorts, Angela; Mah, Jean K; McDonald, Craig; Mehler, Bob; Nelson, Sally; Nikrad, Malti; Singer, Britta; Steele, Fintan; Sterling, David; Sweeney, H Lee; Williams, Steve; Gold, Larry
2015-06-09
Serum biomarkers in Duchenne muscular dystrophy (DMD) may provide deeper insights into disease pathogenesis, suggest new therapeutic approaches, serve as acute read-outs of drug effects, and be useful as surrogate outcome measures to predict later clinical benefit. In this study a large-scale biomarker discovery was performed on serum samples from patients with DMD and age-matched healthy volunteers using a modified aptamer-based proteomics technology. Levels of 1,125 proteins were quantified in serum samples from two independent DMD cohorts: cohort 1 (The Parent Project Muscular Dystrophy-Cincinnati Children's Hospital Medical Center), 42 patients with DMD and 28 age-matched normal volunteers; and cohort 2 (The Cooperative International Neuromuscular Research Group, Duchenne Natural History Study), 51 patients with DMD and 17 age-matched normal volunteers. Forty-four proteins showed significant differences that were consistent in both cohorts when comparing DMD patients and healthy volunteers at a 1% false-discovery rate, a large number of significant protein changes for such a small study. These biomarkers can be classified by known cellular processes and by age-dependent changes in protein concentration. Our findings demonstrate both the utility of this unbiased biomarker discovery approach and suggest potential new diagnostic and therapeutic avenues for ameliorating the burden of DMD and, we hope, other rare and devastating diseases.
López Uriarte, Graciela Arelí; Burciaga Flores, Carlos Horacio; Torres de la Cruz, Víctor Manuel; Medina Aguado, María Magdalena; Gómez Puente, Viviana Maricela; Romero Gutiérrez, Liliana Nayeli; Martínez de Villarreal, Laura Elia
2018-06-01
Prenatal diagnosis of Down syndrome (DS) is based on the calculated risk of maternal age, biochemical and ultrasonographic markers and recently by cfDNA. Differences in proteomic profiles may give an opportunity to find new biomarkers. Characterize proteome of serum of mothers carrying DS fetus. Blood serum samples of three groups of women were obtained, (a) 10 non-pregnant, (b) 10 pregnant with healthy fetus by ultrasound evaluation, (c) nine pregnant with DS fetus. Sample preparation was as follows: Albumin/IgG depletion, desalting, and trypsin digestion; the process was performed in nanoUPLC MS/MS. Data analysis was made with Mass Lynx 4.1 and ProteinLynx Global Server 3.0, peptide and protein recognition by MASCOT algorithm and UNIPROT-Swissprot database. Each group showed different protein profiles. Some proteins were shared between groups. Only sera from pregnant women showed proteins related to immune and clot pathways. Mothers with DS fetus had 42 specific proteins. We found a different serum protein profile in mothers carrying DS fetuses that do not reflect expression of genes in the extra chromosome. Further studies will be necessary to establish the role of these proteins in aneuploid fetus and analyze their possible use as potential biomarkers.
NASA Astrophysics Data System (ADS)
Liao, Fadian; Ruan, Qiuyong; Lin, Juqiang; Lin, Jinyong; Zeng, Yongyi; Li, Ling; Huang, Zufang; Liu, Nenrong; Chen, Rong
2014-09-01
Despite the introduction of high-technology methods of detection and diagnosis, screening of primary liver cancer (PLC) remains imperfect. To diagnosis PLC earlier, Surface-enhanced Raman spectroscopy (SERS) coupled with cellulose-acetate membrane electrophoresis were introduced to separate human serum albumin and SERS spectra. Three groups (15 normal persons' samples, 17 hepatitis/cirrhosis samples, 15 cases of PLC) of serum albumin were tested. Silver colloid was used to obtain SERS spectra of human serum albumin. Principal component analysis (PCA) and linear discriminant analysis (LDA) were also employed for statistical analysis. The mean Raman spectra of three groups and the difference spectra of any two suggested that the albumin has changed in liver patients. Compared to normal groups, some Raman peaks have shifted or even disappeared in hepatitis/cirrhosis and PLCs groups. The sensitivity and specificity between PLCs and normal groups is 80% and 93.3%. Among hepatitis/cirrhosis and normal groups, the sensitivity is 88.2% and specificity is also 93.3%. Besides, the sensitivity and specificity between PLCs and hepatitis/cirrhosis groups is 86.7% and 76.5%. All the above data and results indicated that early screening of PLC is potential by SERS in different stages of liver disease before cancer occurs.
Microcontroller-based system for estimate of calcium in serum samples.
Neelamegam, Periyaswmy; Jamaludeen, Abdul Sheriff; Ragendran, Annamalai; Murugrananthan, Krishanamoorthy
2010-01-01
In this study, a microcontroller-based control unit was designed and constructed for the estimation of serum calcium in blood samples. The proposed optoelectronic instrument used a red light emitting diode (LED) as a light source and photodiode as a sensor. The performance of the system was compared with that of a commercial instrument in measuring calcium ion. The quantitative analysis of calcium in a catalyst using arsenazo III as colorimetric reagent was used to test the device. The calibration curve for calcium binding with arsenazo III was drawn to check the range of linearity, which was between 0.1 to 4.5 mM L⁻¹. The limit of detection (LOD) is 0.05 mM L⁻¹. Absorbance changes over the pH range of 2-12 were determined to optimize the assay, with maximum absorption at pH 9.0. Interferences in absorbance from monovalent (K+ and Na+) and divalent (Mg²+) cations were also studied. The results show that the system works successfully.
Sia, I G; Wilson, J A; Espy, M J; Paya, C V; Smith, T F
2000-02-01
Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients.
Sia, Irene G.; Wilson, Jennie A.; Espy, Mark J.; Paya, Carlos V.; Smith, Thomas F.
2000-01-01
Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients. PMID:10655353
Bakken, L L; Callister, S M; Wand, P J; Schell, R F
1997-01-01
In 1991, we reported that 55% of laboratories participating in the Wisconsin Proficiency Testing Program could not accurately identify serum samples from Lyme disease patients containing antibody against Borrelia burgdorferi. The purpose of this study was to determine whether the accuracy of Lyme disease test results reported by approximately 500 participants in the Wisconsin State Laboratory of Hygiene/College of American Pathologists Lyme Disease Survey had improved. From 1992 through 1994, 50 serum samples were sent to participants of the survey. Each laboratory received 28 serum samples from individuals with Lyme disease according to the case definition of the Centers for Disease Control and Prevention and 22 serum samples from healthy individuals. Unfortunately, the serodiagnosis of Lyme disease by participants had not improved. The specificity of the Lyme disease assays steadily decreased from approximately 95% to approximately 81% during the 3-year period of the survey. False-positive test results approached 55% with some of the serum samples from healthy donors. A serum sample containing antibody against Treponema pallidum was reported as positive by 70% of the participants. In addition, the sensitivity fluctuated between 93 and 75%, depending upon the conjugate used by the laboratories. These results suggest that stronger criteria must be applied for approving and continuing to approve commercially available kits for the serodiagnosis of Lyme disease. PMID:9041384
Tinkov, Alexey A; Skalnaya, Margarita G; Demidov, Vasily A; Serebryansky, Eugeny P; Nikonorov, Alexandr A; Skalny, Anatoly V
2014-12-01
The primary objective of the research is to estimate the dependence between hair mercury content, hair selenium, mercury-to-selenium ratio, serum lipid spectrum, and gamma-glutamyl transferase (GGT) activity in 63 adults (40 men and 23 women). Serum triglyceride (TG) concentration in the high-mercury group significantly exceeded the values obtained for low- and medium-mercury groups by 72 and 42 %, respectively. Serum GGT activity in the examinees from high-Hg group significantly exceeded the values of the first and the second groups by 75 and 28 %, respectively. Statistical analysis of the male sample revealed similar dependences. Surprisingly, no significant changes in the parameters analyzed were detected in the female sample. In all analyzed samples, hair mercury was not associated with hair selenium concentrations. Significant correlation between hair mercury content and serum TG concentration (r = 0.531) and GGT activity (r = 0.524) in the general sample of the examinees was detected. The respective correlations were observed in the male sample. Hair mercury-to-selenium ratios significantly correlated with body weight (r = 0.310), body mass index (r = 0.250), serum TG (r = 0.389), atherogenic index (r = 0.257), and GGT activity (r = 0.393). The same correlations were observed in the male sample. Hg/Se ratio in women did not correlate with the analyzed parameters. Generally, the results of the current study show the following: (1) hair mercury is associated with serum TG concentration and GGT activity in men, (2) hair selenium content is not related to hair mercury concentration, and (3) mercury-to-selenium ratio correlates with lipid spectrum parameters and GGT activity.
Focant, Jean-François; Eppe, Gauthier; Massart, Anne-Cécile; Scholl, Georges; Pirard, Catherine; De Pauw, Edwin
2006-10-13
We report on the use of a state-of-the-art method for the measurement of selected polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and polychlorinated biphenyls in human serum specimens. The sample preparation procedure is based on manual small size solid-phase extraction (SPE) followed by automated clean-up and fractionation using multi-sorbent liquid chromatography columns. SPE cartridges and all clean-up columns are disposable. Samples are processed in batches of 20 units, including one blank control (BC) sample and one quality control (QC) sample. The analytical measurement is performed using gas chromatography coupled to isotope dilution high-resolution mass spectrometry. The sample throughput corresponds to one series of 20 samples per day, from sample reception to data quality cross-check and reporting, once the procedure has been started and series of samples keep being produced. Four analysts are required to ensure proper performances of the procedure. The entire procedure has been validated under International Organization for Standardization (ISO) 17025 criteria and further tested over more than 1500 unknown samples during various epidemiological studies. The method is further discussed in terms of reproducibility, efficiency and long-term stability regarding the 35 target analytes. Data related to quality control and limit of quantification (LOQ) calculations are also presented and discussed.
Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS
NASA Astrophysics Data System (ADS)
Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.
2013-09-01
Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.
Hart, Leslie B; Wells, Randall S; Kellar, Nick; Balmer, Brian C; Hohn, Aleta A; Lamb, Stephen V; Rowles, Teri; Zolman, Eric S; Schwacke, Lori H
2015-01-01
Inshore common bottlenose dolphins (Tursiops truncatus) are exposed to a broad spectrum of natural and anthropogenic stressors. In response to these stressors, the mammalian adrenal gland releases hormones such as cortisol and aldosterone to maintain physiological and biochemical homeostasis. Consequently, adrenal gland dysfunction results in disruption of hormone secretion and an inappropriate stress response. Our objective herein was to develop diagnostic reference intervals (RIs) for adrenal hormones commonly associated with the stress response (i.e., cortisol, aldosterone) that account for the influence of intrinsic (e.g., age, sex) and extrinsic (e.g., time) factors. Ultimately, these reference intervals will be used to gauge an individual's response to chase-capture stress and could indicate adrenal abnormalities. Linear mixed models (LMMs) were used to evaluate demographic and sampling factors contributing to differences in serum cortisol and aldosterone concentrations among bottlenose dolphins sampled in Sarasota Bay, Florida, USA (2000-2012). Serum cortisol concentrations were significantly associated with elapsed time from initial stimulation to sample collection (p<0.05), and RIs were constructed using nonparametric methods based on elapsed sampling time for dolphins sampled in less than 30 minutes following net deployment (95% RI: 0.91-4.21 µg/dL) and following biological sampling aboard a research vessel (95% RI: 2.32-6.68 µg/dL). To examine the applicability of the pre-sampling cortisol RI across multiple estuarine stocks, data from three additional southeast U.S. sites were compared, revealing that all of the dolphins sampled from the other sites (N = 34) had cortisol concentrations within the 95th percentile RI. Significant associations between serum concentrations of aldosterone and variables reported in previous studies (i.e., age, elapsed sampling time) were not observed in the current project (p<0.05). Also, approximately 16% of Sarasota Bay bottlenose dolphin aldosterone concentrations were below the assay's detection limit (11 pg/mL), thus hindering the ability to derive 95th percentile RIs. Serum aldosterone concentrations from animals sampled at the three additional sites were compared to the detection limit, and the proportion of animals with low aldosterone concentrations was not significantly different than an expected prevalence of 16%. Although this study relied upon long-term, free-ranging bottlenose dolphin health data from a single site, the objective RIs can be used for future evaluation of adrenal function among individuals sampled during capture-release health assessments.
Stevens, Servi J. C.; Pronk, Inge; Middeldorp, Jaap M.
2001-01-01
Epstein-Barr virus (EBV) DNA load monitoring in peripheral blood has been shown to be a useful tool for the diagnosis of aberrant EBV infections. In the present study we compared the relative diagnostic values of EBV DNA load monitoring in unfractionated whole blood and simultaneously obtained serum or plasma samples from Burkitt's lymphoma (BL) patients, transplant recipients, human immunodeficiency virus (HIV)-infected individuals, and infectious mononucleosis (IM) patients by a quantitative competitive PCR (Q-PCR). The EBV DNA load in BL patients was mainly situated in the cellular blood compartment (up to 4.5 × 106 copies/ml). EBV DNA loads in unfractionated whole blood and parallel serum samples showed no correlation. In transplant recipients, IM patients, and HIV-infected patients, the EBV burden in the circulation was almost exclusively restricted to the cellular blood compartment, because serum or plasma samples from these patients yielded negative results by Q-PCR, despite high viral loads in corresponding whole-blood samples. A 10-fold more sensitive but qualitative BamHI-W-repeat PCR occasionally revealed the presence of EBV at <2,000 copies of EBV DNA per ml of serum. Spiking of 100 copies of EBV DNA in samples with negative Q-PCR results excluded the presence of inhibitory factors in serum or plasma that influenced the Q-PCR result. Serum samples from all populations were often positive for β-globin DNA, indicating cell damage in vivo or during serum preparation. We conclude that serum is an undesirable clinical specimen for EBV DNA load monitoring because it omits the presence of cell-associated virus and uncontrolled cell lysis may give irreproducible results or overestimation of the DNA load. Unfractionated whole blood is strongly preferred since it combines all blood compartments that may harbor EBV and it best reflects the absolute viral burden in the patient's circulation. PMID:11283029
Butler, Emily K; Gersch, Jeffrey; McNamara, Anne; Luk, Ka-Cheung; Holzmayer, Vera; de Medina, Maria; Schiff, Eugene; Kuhns, Mary; Cloherty, Gavin A
2018-05-07
Treatment of chronic hepatitis B (CHB) patients with nucleos(t)ide analogues (NA) suppresses HBV DNA synthesis but does not affect synthesis of HBV pregenomic RNA (pgRNA). HBV pgRNA is detectable in the serum during NA treatment and has been proposed as a marker of HBV covalently closed circular DNA (cccDNA) activity within the infected hepatocyte. We developed an automated assay for the quantification of serum HBV pgRNA using a dual-target qRT-PCR approach on the Abbott m2000sp/rt system. We demonstrate accurate detection and quantification of serum HBV RNA. HBV DNA was quantified using the Abbott RealTime HBV viral load assay. We further compared serum nucleic acid levels and kinetics in HBV-positive populations. Samples included: on-therapy CHB samples (N=16), samples (N=89) from 10 treatment naïve CHB subjects receiving 12-weeks of NA treatment with 8-week follow-up, HBsAg-positive blood donor samples (N=102), and 3 seroconversion series from plasmapheresis donors (N=79 samples). During NA treatment of CHB subjects, we observed low correlation of HBV DNA to pgRNA levels; pgRNA concentration was generally higher than HBV DNA concentrations. In contrast, when NA treatment was absent we observed serum pgRNA at concentrations that correlated to HBV DNA and were approximately 2 log lower than HBV DNA. Importantly, we observe this trend in untreated subject samples from both chronic infections and throughout seroconversion during acute infection. Results demonstrate that the presence of pgRNA in serum is part of the HBV lifecycle; constant relative detection of pgRNA and HBV DNA in the serum is suggestive of a linked mechanism for egress for HBV DNA or pgRNA containing virions. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.
Biomonitoring Hexamethylene diisocyanate (HDI) exposure based on serum levels of HDI-specific IgG.
Wisnewski, Adam V; Stowe, Meredith H; Nerlinger, Abby; Opare-Addo, Paul; Decamp, David; Kleinsmith, Christopher R; Redlich, Carrie A
2012-10-01
Isocyanate chemicals essential for polyurethane production are widely used industrially, and are increasingly found in consumer products. Asthma and other adverse health effects of isocyanates are well-documented and exposure surveillance is crucial to disease prevention. Hexamethylene diisocyanate (HDI)-specific serum immunoglobulin G (IgG) was evaluated as an exposure biomarker among workers at a US Air Force Air Logistics Center, which includes a large aircraft maintenance facility. HDI-specific IgG (HDI-IgG) titers in serum samples (n = 74) were measured using an enzyme-linked immunosorbent assay based upon the biuret form of HDI conjugated to human albumin. Information on personal protective equipment (PPE), work location/tasks, smoking, asthma history, basic demographics, and HDI skin exposure was obtained through questionnaire. HDI-specific serum IgG levels were elevated in n = 17 (23%) of the workers studied. The prevalence and/or end-titer of the HDI-IgG was significantly (P < 0.05) associated with specific job titles, self-reported skin exposure, night-shift work, and respirator use, but not atopy, asthma, or other demographic information. The highest titers were localized to specific worksites (C-130 painting), while other worksites (generator painting) had no or few workers with detectable HDI-IgG. HDI-specific immune responses (IgG) provide a practical biomarker to aid in exposure surveillance and ongoing industrial hygiene efforts. The strategy may supplement current air sampling approaches, which do not assess exposures via skin, or variability in PPE use or effectiveness. The approach may also be applicable to evaluating isocyanate exposures in other settings, and may extend to other chemical allergens.
NASA Astrophysics Data System (ADS)
Lin, Tianran; Zhong, Liangshuang; Guo, Liangqia; Fu, Fengfu; Chen, Guonan
2014-09-01
Molybdenum disulfide (MoS2) has attracted increasing research interest recently due to its unique physical, optical and electrical properties, correlated with its 2D ultrathin atomic-layered structure. Until now, however, great efforts have focused on its applications such as lithium ion batteries, transistors, and hydrogen evolution reactions. Herein, for the first time, MoS2 nanosheets are discovered to possess an intrinsic peroxidase-like activity and can catalytically oxidize 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2 to produce a color reaction. The catalytic activity follows the typical Michaelis-Menten kinetics and is dependent on temperature, pH, H2O2 concentration, and reaction time. Based on this finding, a highly sensitive and selective colorimetric method for H2O2 and glucose detection is developed and applied to detect glucose in serum samples. Moreover, a simple, inexpensive, instrument-free and portable test kit for the visual detection of glucose in normal and diabetic serum samples is constructed by utilizing agarose hydrogel as a visual detection platform.Molybdenum disulfide (MoS2) has attracted increasing research interest recently due to its unique physical, optical and electrical properties, correlated with its 2D ultrathin atomic-layered structure. Until now, however, great efforts have focused on its applications such as lithium ion batteries, transistors, and hydrogen evolution reactions. Herein, for the first time, MoS2 nanosheets are discovered to possess an intrinsic peroxidase-like activity and can catalytically oxidize 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2 to produce a color reaction. The catalytic activity follows the typical Michaelis-Menten kinetics and is dependent on temperature, pH, H2O2 concentration, and reaction time. Based on this finding, a highly sensitive and selective colorimetric method for H2O2 and glucose detection is developed and applied to detect glucose in serum samples. Moreover, a simple, inexpensive, instrument-free and portable test kit for the visual detection of glucose in normal and diabetic serum samples is constructed by utilizing agarose hydrogel as a visual detection platform. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr03393k
Katsoulos, Panagiotis D; Athanasiou, Labrini V; Karatzia, Maria A; Giadinis, Nektarios; Karatzias, Harilaos; Boscos, Constantin; Polizopoulou, Zoe S
2017-12-01
Determination of serum total protein concentration is commonly performed by the biuret method. Refractometric measurement is a faster and less expensive alternative but its accuracy has not been determined in ruminants. The purpose of the study was to compare the serum total protein concentrations in cattle, sheep, and goats measured by the biuret method with those obtained by refractometry. Serum total protein concentration was determined in 120 cattle, 67 sheep, and 58 goat blood samples refractometrically and with the biuret method. The data were analyzed with a paired samples t-test, and Passing and Bablok regression equations and Bland and Altman plots were generated. There was a strong linear relationship between the total protein values determined with the refractometer and the biuret method in cattle, sheep, and goats. The statistical accuracy, which represents a bias correction factor that measures the deviation of the best-fit line from the 45° line through the origin, was 90.63% for cattle, 93.05% for sheep, and 91.76% for goats. The mean protein values determined with the refractometer were significantly lower than those measured with the biuret method in cattle and goats (P < .05) but not in sheep (P > .05). The evaluated refractometer was sufficiently accurate for the determination of serum total proteins in cattle, sheep, and goats, although it cannot be used interchangeably with the biuret method. The RIs should be corrected for negative bias based on the created equations. © 2017 American Society for Veterinary Clinical Pathology.
NASA Astrophysics Data System (ADS)
Hernández-Caraballo, Edwin A.; Burguera, Marcela; Burguera, José L.
2002-12-01
A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH 4OH+0.05% w/v Triton X-100 ®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO 3) 2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1 -1 Se, corresponding to 30 μg l -1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l -1, with a mean value of 114±22 μg l -1.
NASA Astrophysics Data System (ADS)
Li, S. X.; Zhang, Y. J.; Zeng, Q. Y.; Li, L. F.; Guo, Z. Y.; Liu, Z. M.; Xiong, H. L.; Liu, S. H.
2014-06-01
Cancer is the most common disease to threaten human health. The ability to screen individuals with malignant tumours with only a blood sample would be greatly advantageous to early diagnosis and intervention. This study explores the possibility of discriminating between cancer patients and normal subjects with serum surface-enhanced Raman spectroscopy (SERS) and a support vector machine (SVM) through a peripheral blood sample. A total of 130 blood samples were obtained from patients with liver cancer, colonic cancer, esophageal cancer, nasopharyngeal cancer, gastric cancer, as well as 113 blood samples from normal volunteers. Several diagnostic models were built with the serum SERS spectra using SVM and principal component analysis (PCA) techniques. The results show that a diagnostic accuracy of 85.5% is acquired with a PCA algorithm, while a diagnostic accuracy of 95.8% is obtained using radial basis function (RBF), PCA-SVM methods. The results prove that a RBF kernel PCA-SVM technique is superior to PCA and conventional SVM (C-SVM) algorithms in classification serum SERS spectra. The study demonstrates that serum SERS, in combination with SVM techniques, has great potential for screening cancerous patients with any solid malignant tumour through a peripheral blood sample.
Gouveia, Liana Ribeiro; Santos, Joelma Carvalho; Silva, Ronaldo Dionísio; Batista, Andrea Dória; Domingues, Ana Lúcia Coutinho; Lopes, Edmundo Pessoa de Almeida; Silva, Ricardo Oliveira
2017-01-01
Diagnosis of liver involvement due to schistosomiasis in asymptomatic patients from endemic areas previously diagnosed with chronic hepatitis B (HBV) or C (HCV) and periportal fibrosis is challenging. H-1 Nuclear Magnetic Resonance (NMR)-based metabonomics strategy is a powerful tool for providing a profile of endogenous metabolites of low molecular weight in biofluids in a non-invasive way. The aim of this study was to diagnose periportal fibrosis due to schistosomiasis mansoni in patients with chronic HBV or HCV infection through NMR-based metabonomics models. The study included 40 patients divided into two groups: (i) 18 coinfected patients with schistosomiasis mansoni and HBV or HCV; and (ii) 22 HBV or HCV monoinfected patients. The serum samples were analyzed through H-1 NMR spectroscopy and the models were based on Principal Component Analysis (PCA) and Partial Least Squares-Discriminant Analysis (PLS-DA). Ultrasonography examination was used to ascertain the diagnosis of periportal fibrosis. Exploratory analysis showed a clear separation between coinfected and monoinfected samples. The supervised model built from PLS-DA showed accuracy, R2 and Q2 values equal to 100%, 98.1% and 97.5%, respectively. According to the variable importance in the projection plot, lactate serum levels were higher in the coinfected group, while the signals attributed to HDL serum cholesterol were more intense in the monoinfected group. The metabonomics models constructed in this study are promising as an alternative tool for diagnosis of periportal fibrosis by schistosomiasis in patients with chronic HBV or HCV infection from endemic areas for Schistosoma mansoni.
Perut, Francesca; Dallari, Dante; Rani, Nicola; Baldini, Nicola; Granchi, Donatella
Regenerative strategies based on the use of platelet concentrates as an autologous source of growth factors (GF) has been proposed to promote the healing of long bone nonunions. However, the relatively high failure rate stimulates interest in growing knowledge and developing solutions to obtain the best results from the regenerative approach. In this study we evaluated whether a cell-based assay system could be able to recognize patients who will benefit or not from the use of autologous platelet preparations. The autologous serum was used in culture medium to promote the osteogenic differentiation of normal bone-marrow stromal cells (BMSC). Blood samples were collected from 16 patients affected by aseptic long bone nonunion who were candidates to the treatment with autologous platelet-rich fibrin. The osteoinductive effect was detected by measuring the BMSC proliferation, the mineralization activity, and the expression of bone-related genes. Serum level of basic fibroblast growth factor (bFGF) was considered as a representative marker of the delivery of osteogenic GFs from platelets. Laboratory results were related to the characteristics of the disease before the treatment and to the outcome at 12 months. Serum samples from "good responders" showed significantly higher levels of bFGF and were able to induce a significantly higher proliferation of BMSC, while no significant differences were observed in terms of osteoblast differentiation. BMSC-based assay could be a useful tool to recognize patients who have a low probability to benefit from the use of autologous platelet concentrate to promote the healing of long bone nonunion.
Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong; Li, Ning
2016-12-01
Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC ( n = 65) and healthy control subjects ( n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC.
Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong
2016-01-01
Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC (n = 65) and healthy control subjects (n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC. PMID:27885040
Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L
2017-06-03
Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p < 0.004). In summary, when considering the acceptable change limit, BDNF was stable in serum and in EDTA-plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.
Serum TNF-α levels and Helicobacter pylori cagA and vacA genes
NASA Astrophysics Data System (ADS)
Siregar, G. A.; Halim, S.; Sitepu, R. R.; Darmadi
2018-03-01
Helicobacter pylori is associated with higher virulence. TNF-α has an important role in host defense against H. pylori infection. The aim of this study was to investigate the relationship between TNF-α serum levels with cagA and vacA genes in H. pylori infection. This was a cross-sectional study involving 80 patients that consecutively admitted to endoscopy unit. Diagnosis of H. pylori infection was based on rapid urease test. Serum samples werecollected to determine circulating TNF-α level. Polymerase chain reaction was done to examine H. pylori vacA and cagA genes. Data analysis was carriedout using SPSS version 22 with 95%CI and p<0.05 was considered statistically significant. About 45 (56.3%) patients infected with Helicobacter pylori. There were 33 (73.3%) patients with H. pylori cagA positive. Serum TNF-α levels in patients with the H. pylori positive were significantly higher compared to H. pylori negative. Serum level of TNF-α was significantly higher in cagA positive than negative. Subjects with H. pylori cagA gene positive were more likely to have ahigher level of serum TNF-α than H. pylori cagA gene negative.
Tian, Jianniao; Zhou, Liujin; Zhao, Yanchun; Wang, Yuan; Peng, Yan; Zhao, Shulin
2012-04-15
A multicolor quantum dot (QD)-based nanosensor for multiplex detection of two tumor markers in a homogeneous format based on fluorescence polarization immunoassay was proposed. QDs520 and QDs620 were labeled alpha-fetoprotein(α-AFP) and carcinoembryonic antigen (CEA), respectively. After separated and purified by ultrafiltration, they were used in fluorescence polarization immunoassay for the simultaneous detection of human serum alpha-fetoprotein and carcinoembryonic antigen. Under the optimal conditions, the multi-analyte immunosensor had a wide linear range (from 0.5 ng mL(-1) to 500 ng mL(-1)) for both two tumor markers and good correlation (0.996 for α-AFP and 0.993 for CEA). The detection limits (LOD) were 0.36 ng mL(-1) for CEA and 0.28 ng mL(-1) for α-AFP (S/N=3). The carcinoembryonic antigen and fetoprotein in clinical serum samples were simultaneously detected. The results from 28 serum samples had a good agreement with enzyme-linked immunosorbent assay (ELISA). The relative standard deviation and the recovery suggested that the precision and the accuracy of this analytical method were satisfactory. This strategy with high sensitivity, good specificity, easy procedures and short analysis time shows great promise for clinical diagnoses and basic discovery. The application of QDs with longer fluorescence lifetime and small fluorescence polarization can be used for the determination of high molecular-weight substances which cannot be analyzed using dye fluorescence polarization immunoassay. Copyright © 2012 Elsevier B.V. All rights reserved.
Serum and saliva cortisol relations in adolescents during pregnancy and the early postpartum period.
Dorn, L D; Susman, E J
1993-08-15
The purpose of this investigation was to examine: (1) relations between serum and saliva cortisol in adolescents in pregnancy and early postpartum and (2) short-term consistency of serum and saliva cortisol across three samples, 20 minutes apart, as well as the long-term consistency from pregnancy to early postpartum. Pregnant adolescents (n = 40), ages 14 to 19 years, were enrolled in this study. Subjects were seen at 20 weeks gestation or earlier (T1), 34-36 weeks gestation (T2), and 2-3 weeks postpartum (T3). Blood samples were drawn at T1 and T3, at 0, 20, and 40 minutes. Saliva samples were collected across the same 40-minute period at T1, T2, and T3. Spearman rho (rs) correlation coefficients between serum and saliva ranged from 0.72 to 0.77 (T1), and 0.42 to 0.60 (T3) (p < or = 0.05). Short-term consistency between serum cortisol samples was 0.86-0.97 at T1 and 0.60-0.82 at T3. Short-term consistency for saliva cortisol samples was 0.70-0.96 at T1, 0.91-0.95 at T2, and 0.64-0.89 at T3. Long-term consistency (T1 to T3) for serum and saliva cortisol was low. Individual differences as well as dramatic changes in the endocrine environment in pregnancy and the early postpartum period may explain the more moderate serum-saliva correlations in the postpartum period.
Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav
2009-05-01
Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.
In vitro production of GHB in blood and serum samples under various storage conditions.
Zörntlein, S W; Kopp, A; Becker, J; Kaufmann, T J; Röhrich, J; Urban, R
2012-01-10
The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4°C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sample preparation was performed by means of methanolic extraction following the precipitation of whole blood and serum samples. A methanolic standard calibration was done in a low range of 0.005-0.1 μg/mL (LOD: 0.004, LLOQ: 0.013). For quantification a spiked blood bank serum with a determined GHB concentration of 0.09 μg/mL was used. Corrected calibrations in the range of 0.09-5.09 μg/mL were used (LOD: 0.08 μg/mL, LLOQ: 0.30 μg/mL), recovery: 91.3% (high level: 4.09 μg/mL) 50.5% (low level: 0.19 μg/mL). Relevant elevation of GHB was observed in all whole blood samples stored in liquid form (4°C or room temperature). In two of the 40 whole blood samples stored over a longer period of time at 4°C, GHB concentrations in the range of 13 μg/mL were even determined. These findings constitute grounds for caution. Even a GHB cut-off level of 5 μg/mL cannot be considered as "absolutely positive" proof of a case of exogenous administration, at least in untreated liquid blood samples in long time storage. However, no significant elevations of GHB were otherwise observed in any of the serum samples independently of storage temperature nor in the whole blood samples that were frozen for storage. The results suggest that the cut-off for exogenous GHB of 5 μg/mL could be lowered significantly, with the consequence of winning valuable time for the potential victim, but only if serum is collected for GHB determination or if the whole blood sample is frozen immediately after collection and the procedure well documented. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Stringer, Kathleen A.; Younger, John G.; McHugh, Cora; Yeomans, Larisa; Finkel, Michael A.; Puskarich, Michael A.; Jones, Alan E.; Trexel, Julie; Karnovsky, Alla
2015-01-01
Serum is a common sample of convenience for metabolomics studies. Its processing time can be lengthy and may result in the loss of metabolites including those of red blood cells (RBC). Unlike serum, whole blood (WB) is quickly processed, minimizing the influence of variable hemolysis while including RBC metabolites. To determine differences between serum and WB metabolomes, both sample types, collected from healthy volunteers, were assayed by 1H-NMR spectroscopy. A total of 34 and 50 aqueous metabolites were quantified from serum and WB, respectively. Free hemoglobin (Hgb) levels in serum were measured and the correlation between Hgb and metabolite concentrations was determined. All metabolites detected in serum were at higher concentrations in WB with the exception of acetoacetate and propylene glycol. The 18 unique metabolites of WB included adenosine, AMP, ADP and ATP, which are associated with RBC metabolism. The use of serum results in the underrepresentation of a number of metabolic pathways including branched chain amino acid degradation and glycolysis and gluconeogenesis. The range of free Hgb in serum was 0.03-0.01 g/dL and 8 metabolites were associated (p ≤ 0.05) with free Hgb. The range of free Hgb in serum samples from 18 sepsis patients was 0.02-0.46 g/dL. WB and serum have unique aqueous metabolite profiles but the use of serum may introduce potential pathway bias. Use of WB for metabolomics may be particularly important for studies in diseases like sepsis in which RBC metabolism is altered and mechanical and sepsis-induced hemolysis contributes to variance in the metabolome. PMID:26009817
Liu, Jiayou; O'Connor, Thomas; Beall, Melissa; Chandrashekar, Ramaswamy; Lappin, Michael
2016-01-01
Feline leukemia virus (FeLV) is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories), the WITNESS FeLV-FIV Test (Zoetis) and the VetScan Feline FeLV/FIV Rapid Test (Abaxis). The sample population (100 positive, 105 negative samples) consisted of serum and plasma samples submitted to IDEXX's worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis) microtiter plate assay. The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%); Zoetis WITNESS (positive 79.0%, negative 97.1%); Abaxis VetScan (positive 73.0%, negative 97.1%). The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.
Zhao, Changzhi; Wan, Li; Jiang, Li; Wang, Qin; Jiao, Kui
2008-12-01
A cholesterol biosensor based on direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode has been developed for highly sensitive and selective analysis of serum samples. Modified by films containing hemoglobin and cholesterol oxidase, the electrode was prepared by encapsulation of enzyme in chitosan matrix. The hydrogen peroxide produced by the catalytic oxidation of cholesterol by cholesterol oxidase was reduced electrocatalytically by immobilized hemoglobin and used to obtain a sensitive amperometric response to cholesterol. The linear response of cholesterol concentrations ranged from 1.00 x 10(-5) to 6.00 x 10(-4) mol/L, with a correlation coefficient of 0.9969 and estimated detection limit of cholesterol of 9.5 micromol/L at a signal/noise ratio of 3. The cholesterol biosensor can efficiently exclude interference by the commonly coexisting ascorbic acid, uric acid, dopamine, and epinephrine. The sensitivity to the change in the concentration of cholesterol as the slope of the calibration curve was 0.596 A/M. The relative standard deviation was under 4.0% (n=5) for the determination of real samples. The biosensor is satisfactory in the determination of human serum samples.
Serum PARC/CCL-18 concentrations and health outcomes in chronic obstructive pulmonary disease.
Sin, Don D; Miller, Bruce E; Duvoix, Annelyse; Man, S F Paul; Zhang, Xuekui; Silverman, Edwin K; Connett, John E; Anthonisen, Nicholas A; Wise, Robert A; Tashkin, Donald; Celli, Bartolome R; Edwards, Lisa D; Locantore, Nicholas; Macnee, William; Tal-Singer, Ruth; Lomas, David A
2011-05-01
There are no accepted blood-based biomarkers in chronic obstructive pulmonary disease (COPD). Pulmonary and activation-regulated chemokine (PARC/CCL-18) is a lung-predominant inflammatory protein that is found in serum. To determine whether PARC/CCL-18 levels are elevated and modifiable in COPD and to determine their relationship to clinical end points of hospitalization and mortality. PARC/CCL-18 was measured in serum samples from individuals who participated in the ECLIPSE (Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints) and LHS (Lung Health Study) studies and a prednisolone intervention study. Serum PARC/CCL-18 levels were higher in subjects with COPD than in smokers or lifetime nonsmokers without COPD (105 vs. 81 vs. 80 ng/ml, respectively; P < 0.0001). Elevated PARC/CCL-18 levels were associated with increased risk of cardiovascular hospitalization or mortality in the LHS cohort and with total mortality in the ECLIPSE cohort. Serum PARC/CCL-18 levels are elevated in COPD and track clinical outcomes. PARC/CCL-18, a lung-predominant chemokine, could be a useful blood biomarker in COPD.
Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah
2015-01-01
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1 and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum. PMID:26330859
Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum.
Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah
2015-01-01
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1) and 2-20 μg mL(-1) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum.
Association of canine obesity with reduced serum levels of C-reactive protein.
Veiga, Angela P M; Price, Christopher A; de Oliveira, Simone T; Dos Santos, Andréa P; Campos, Rómulo; Barbosa, Patricia R; González, Félix H D
2008-03-01
The prevalence of obesity is increasing in dogs as well as in humans. C-reactive protein (CRP) is an important tool for the detection of inflammation and/or early tissue damage and is linked to obesity in humans. The objective of the present study was to determine if serum CRP levels are altered in obese dogs. Fifteen lean (control group) and 16 overweight (obese group) dogs were examined. Blood samples were collected under fasted conditions for serum determination of CRP, glucose, insulin, cholesterol, triglyceride, and fructosamine. Results indicated that obese dogs were insulin resistant because serum insulin and insulin/glucose ratios were higher than in lean dogs (P < or = 0.05). Serum CRP concentrations were lower in obese dogs than in controls (P < or = 0.001). C-reactive protein was negatively correlated with insulin/glucose ratio (R = -0.42) and cholesterol (R = -0.39; P < or = 0.05). Furthermore, levels of cholesterol, triglycerides, and fructosamine were increased in the obese group compared with the control group. Based on these results, it can be postulated that CRP production is inhibited by obesity and insulin resistance in dogs.
Levitan, Daniel; Harper, Aaron E; Sun, Yi; Scarpa Carniello, Jose V; Momeni, Amir; Kagan, Joshua; Alexis, Herol; Eid, Ikram; Harris, Loretta; Marshal, Barbara; Tafani, Edlira; Pincus, Matthew
2017-01-01
The goal of this work was to determine whether there are clinically significant fluctuations in the level of serum creatinine on serial determinations, especially in the borderline range (1.1-1.3 mg/dl), after specimen storage. Sixty-one serum samples were analyzed. They were divided into three categories based on the initial serum creatinine measurement: low (≤1.0 mg/dl), borderline (1.1-1.3 mg/dl), and high (≥1.4 mg/dl). The specimens were stored at 4°C and run on the Siemens Advia 1800 chemistry analyzer on days 1, 3, and 11. Statistical comparisons of the three groups were made using the unpaired t-test, yielding a two-tailed P-value for each group comparison. The P-values ranged from 0.0829 to 0.3892, indicating no statistically significant difference between the standard deviations of each group. Mild-to-moderate fluctuations in precision occur in successive serum creatinine determinations. The overwhelming majority of these fluctuations should not affect clinical decision making. © 2016 Wiley Periodicals, Inc.
Antibodies against MERS coronavirus in dromedary camels, United Arab Emirates, 2003 and 2013.
Meyer, Benjamin; Müller, Marcel A; Corman, Victor M; Reusken, Chantal B E M; Ritz, Daniel; Godeke, Gert-Jan; Lattwein, Erik; Kallies, Stephan; Siemens, Artem; van Beek, Janko; Drexler, Jan F; Muth, Doreen; Bosch, Berend-Jan; Wernery, Ulrich; Koopmans, Marion P G; Wernery, Renate; Drosten, Christian
2014-04-01
Middle East respiratory syndrome coronavirus (MERS-CoV) has caused an ongoing outbreak of severe acute respiratory tract infection in humans in the Arabian Peninsula since 2012. Dromedary camels have been implicated as possible viral reservoirs. We used serologic assays to analyze 651 dromedary camel serum samples from the United Arab Emirates; 151 of 651 samples were obtained in 2003, well before onset of the current epidemic, and 500 serum samples were obtained in 2013. Recombinant spike protein-specific immunofluorescence and virus neutralization tests enabled clear discrimination between MERS-CoV and bovine CoV infections. Most (632/651, 97.1%) camels had antibodies against MERS-CoV. This result included all 151 serum samples obtained in 2003. Most (389/651, 59.8%) serum samples had MERS-CoV-neutralizing antibody titers >1,280. Dromedary camels from the United Arab Emirates were infected at high rates with MERS-CoV or a closely related, probably conspecific, virus long before the first human MERS cases.
The WHI offers an opportunity to evaluate ovarian cancer markers and screening decision rules developed and validated in EDRN CVC Studies 2 and 3 in women who were not being screened. It is particularly well suited to validation of risk markers, since many serum samples were drawn well before clinical diagnosis of cancer in the WHI cohorts. A strategy is needed to identify from among the general population of women over the age of 50 those at high-risk for a diagnosis of ovarian/fallopian tube cancer so that they can be referred for appropriate surveillance, imaging or surgical consult. Tools to identify high-risk women will be investigated including serum markers CA125, HE4, MSLN, and MMP7 and epidemiologic risk factors. We will optimize decision rules using stored serum samples from the WHI OS and conduct a simulated prospective validation using stored serum samples from the WHI CT. Decision rules to select women for ovarian cancer screening will be investigated as well as decision rules for use in ovarian cancer screening.
Gil, A.; González, A.; Dal-Ré, R.; Dominguez, V.; Astasio, P.; Aguilar, L.
1997-01-01
Diluted dried blood drops on filter paper were compared with serum samples as a specimen source for qualitative anti-HAV antibody determination by ELISA. A total of 298 serum samples and dried blood drops were collected from a population of healthy adolescents (15.3 +/- 1.2 years old). The prevalence of anti-HAV antibody obtained by testing serum samples was 7.7% (95% CI:4.8 10.1). Compared with serum sampling the sensitivity and specificity of diluted dried blood drops were 91.3 and 99.3%. The positive and negative predictive values were 91.3 and 99.3%, respectively, and the likelihood ratios of positive and negative results were 91 and 0.09. It is proposed that this test represents a reliable procedure for anti-HAV antibody testing. PMID:9129596
A new approach for rapid detection and typing of serum monoclonal components.
Cacoub, P; Camproux, A C; Thiolières, J M; Assogba, U; Hausfater, P; Mallet, A; Foglietti, M J; Piette, J C; Bernard, M
2000-12-01
When used independently, none of the routine methods to explore serum monoclonal components (MC), including: serum protein electrophoresis (SPE), immunoelectrophoresis (IEP), kappa to lambda ratio (KLR) and immunofixation (IFE), provides a comprehensive quantitative and qualitative identification of the MC. In the past few years the concept of 'protein profile', based on immunonephelometric quantifications of serum proteins, has become widely used. It consists of a qualitative and quantitative graphic representation of numerous serum proteins including immunoglobulins. Aim of study was to develop a multidimensional model based exclusively on protein profiles labeled the protein profile prediction method (PPPM) to improve routine MC detection and typing. Serum samples from 127 hospitalized patients and 99 healthy blood donors were submitted to all of the following: SPE, IFE, KLR and a protein profile (which included IgM, IgA, IgG, kappa and lambda chain detections and quantification). The presence of a MC using IFE was chosen as the gold standard. Healthy donors and patients were randomly divided into two groups defined as testing and validation groups. A logistic model was designed based on the protein profiles of the testing group leading to the determination of a threshold value (called Z(r)) for MC detection. It was then tested to detect MC in the validation group. Using IFE, 73 MC were found in the 127 hospitalized patients. Using the threshold value for MC detection of Z(r)=1.86, the PPPM showed greater sensitivity (94.6%) in detecting a MC compared to either SPE (64.8%) or KLR (89.2%). This result was obtained without diminished specificity (80.8%). The association of SPE or KLR to PPPM did not significantly increase the sensitivity of the PPPM. In the validation group, for samples which had a high predictive probability of a MC using PPPM, the correct MC typing was identified in up to 77% of sera using PPPM only. These results may be interesting in helping to determine when supplementary IFE analysis is required to qualitatively analyze a MC. PPPM allows MC detection with great sensitivity. The immune protein profile dramatically increases the sensitivity of either SPE and/or KLR in detecting MC and may also allow heavy and light chain typing.
Association between Perfluorinated Compound Exposure and Miscarriage in Danish Pregnant Women
Jensen, Tina Kold; Andersen, Louise Bjørkholt; Kyhl, Henriette Boye; Nielsen, Flemming; Christesen, Henrik Thybo; Grandjean, Philippe
2015-01-01
Perfluorinated alkylated substances (PFAS) have been extensively used in consumer products and humans are widely exposed to these persistent compounds. A recent study found no association between exposure to perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) and miscarriage, but no studies have examined adverse effect of the more recently introduced PFASs. We therefore conducted a case-control study within a population-based, prospective cohort during 2010-2012. Newly pregnant women residing in the Municipality of Odense, Denmark were invited to enroll in the Odense Child Cohort at their first antenatal visit before pregnancy week 12. Among a total of 2,874 participating women, 88 suffered a miscarriage and 59 had stored serum samples, of which 56 occurred before gestational week 12. They were compared to a random sample (N=336) of delivering women, who had also donated serum samples before week 12. Using a case-control design, 51 of the women suffering a miscarriage were matched on parity and gestational day of serum sampling with 204 delivering women. In a multiple logistic regression with adjustment for age, BMI, parity and gestational age at serum sampling, women with the highest tertile of exposure to perfluorononanoic acid (PFNA) and perfluorodecanoic acid (PFDA) in pregnancy had odds ratios for miscarriage of 16.5 (95% CI 7.4-36.6-36.5) and 2.67 (1.31-5.44), respectively, as compared to the lowest tertile. In the matched data set, the OR were 37.9 (9.9-145.2) and 3.71 (1.60-8.60), respectively. The association with perfluorohexane sulfonic acid (PFHxS) was in the same direction, but not statistically significant, while no association was found with PFOA and PFOS. Our findings require confirmation due to the possible public health importance, given that all pregnant women are exposed to these widely used compounds. PMID:25848775
Fujii, Yuji; Henares, Terence G; Kawamura, Kunio; Endo, Tatsuro; Hisamoto, Hideaki
2012-04-21
To enhance sensitivity and facilitate easy sample introduction into a combinable poly(dimethylsiloxane) (PDMS) capillary (CPC) sensor array, PDMS was modified in bulk and on its surface to prepare "black" PDMS coated with a silver layer and self-assembled monolayer (SAM). India ink, a traditional Japanese black ink, was added to the PDMS pre-polymer for bulk modification. The surface was modified by a silver mirror reaction followed by SAM formation using cysteine. These modifications enhanced the fluorescence signals by reflecting them from the surface and reducing background interference. A decrease in the water contact angle led to enhanced sensitivity and easy sample introduction. Furthermore, a CPC sensor array for multiplex detection of serum sample components was prepared that could quantify the analytes glucose, potassium, and alkaline phosphatase (ALP). When serum samples were introduced by capillary action, the CPC sensor array showed fluorescence responses for each analyte and successfully identified the components with elevated concentrations in the serum samples.
Zahraei, Bentolhoda; Hashemzadeh, Mohammad Sadegh; Najarasl, Mohammad; Zahiriyeganeh, Samaneh; Tat, Mahdi; Metanat, Maliheh; Sepehri Rad, Nahid; Khansari-Nejad, Behzad; Zafari, Ehsan; Sharti, Mojtaba; Dorostkar, Ruhollah
2016-01-01
The Crimean-Congo hemorrhagic fever (CCHF) virus causes severe disease in humans, with a high mortality rate. Since, there is no approved vaccine or specific treatment for CCHF, an early and accurate diagnosis, as well as reliable surveillance, is essential for case management and patient improvement. For this research, our aim was to evaluate the application of a novel SYBR Green based one-step real-time reverse-transcriptase polymerase chain reaction (rRT-PCR) assay for the in-house diagnosis of the CCHF virus. In this experimental study, the highly conserved S-region sequence of the CCHF viral genome was first adapted from GenBank, and the specific primers targeting this region were designed. Then, the viral RNA was extracted from 75 serum samples from different patients in eastern Iran. The sensitivity and specificity of the primers were also evaluated in positive serum samples previously confirmed to have the CCHF virus, by this one-step rRT-PCR assay, as well as a DNA sequencing analysis. From a total of 75 suspected serum samples, 42 were confirmed to be positive for CCHF virus, with no false-positives detected by the sequencing results. After 40 amplification cycles, the melting curve analysis revealed a mean melting temperature (Tm) of 86.5 ± 0.6°C (quite different from those of the primer-dimers), and the positive samples showed only a small variation in the parameters. In all of the positive samples, the predicted length of 420 bp was confirmed by electrophoresis. Moreover, the sensitivity test showed that this assay can detect less than 20 copies of viral RNA per reaction. This study showed that this novel one-step rRT-PCR assay is a rapid, reliable, repeatable, specific, sensitive, and simple tool for the detection of the CCHF virus.
Zak, A; Siwinska, N; Slowikowska, M; Borowicz, H; Szpot, P; Zawadzki, M; Niedzwiedz, A
2018-06-19
Capsaicin and dihydrocapsaicin are alkaloids with analgesic effects in humans and animals. When used locally, both of them minimalise pain sensation by defunctionalising nerve endings. According to the Federation Equestrian International Prohibited Substances List, these are substance banned in horse competitions. The aim of the study was to determine the detection time of capsaicin in both plasma and serum after long-term use of a gel recommended for commercial use and applied as intended. The objective of the study was to select the best material for the detection of capsaicin as a doping substance in horses. Nine healthy mature horses were administered 0.1% capsaicin topically in the form of a commercial analgesic gel (15 g of the gel per limb) to the front limbs every 24 hours for five days with a polar fleece bandage. Blood serum and plasma were collected prior to gel application and in the 12th, 18th, 24th, 36th, 42nd, 48th, 60th, 84th, 108th, 132nd, 156th hour after the gel application. Qualitative and quantitative analysis was performed using ultra-high performance liquid chromatography coupled with a triple quadrupole mass spectrometry (UHPLC-QqQ-MS/MS). The concentration of capsaicin in the serum samples did not exceed the lower limit of quantification. Capsaicin was not detected in the plasma samples during the entire study period. Dihydrocapsaicin was not detected in blood serum or plasma. The presented results suggest that capsaicin is not detected in horse serum in the 24-hour-periodfollowing its last application according to the dosage regimen used by owners and veterinarians for therapy rather than doping, based on a five day gel application and a polar bandage.
Smol, Ewa; Kłapcińska, Barbara; Kempa, Katarzyna; Fredyk, Artur; Małecki, Andrzej
2015-01-01
Evidence of the role of ANGPTL3, a liver-secreted glycoprotein, in serum lipid turnover, led us to hypothesize that this protein may be involved in modification of the lipid profile induced by exercise-training. Given the lack of data regarding this issue, the main goal of the present study was to investigate the effects of regular participation in a recreational physical activity program on serum ANGPTL3 and selected lipid profile measures in young, apparently healthy female and male adults. We compared serum ANGPTL3, lipid profile measures, common lipid ratios, the Atherogenic Index of Plasma (AIP) and glucose in fasting blood samples derived from 22 active physical education students including active females (AF, N=6) and males (AM, N=16) with samples from 28 relatively sedentary age-matched peers, including female (SF, N=9) and male (SM, N=19) individuals not involved in any regular physical conditioning program. Despite high inter-individual variability of serum ANGPTL3, there was a general tendency toward higher serum ANGPTL3 and HDL-C in women compared to men, but without significant differences related to their physical activity status. Based on both routine lipid profile measures and lipid ratios, all participants had normal lipid profiles, normal glycemia, as well as favorable anthropometric indices not suggesting increased cardiometabolic risk. However, lower levels of the TG/HDL-C ratio and AIP in physically active compared to relatively sedentary participants, reflecting the predominance of large, buoyant LDL particles, strongly support the view of beneficial health-promoting effects of regular participation in recreational sport activities. PMID:26839611
Bobbo, T; Fiore, E; Gianesella, M; Morgante, M; Gallo, L; Ruegg, P L; Bittante, G; Cecchinato, A
2017-12-01
Blood serum proteins are significant indicators of animal health. Nevertheless, several factors should be considered to appropriately interpret their concentrations in blood. Therefore, the objectives of this study were (1) to assess the effect of herd productivity, breed, age and stage of lactation on serum proteins and (2) to investigate association between serum proteins and somatic cell count (SCC) in dairy cattle. Milk and blood samples were collected from 1508 cows of six different breeds (Holstein Friesian, Brown Swiss, Jersey, Simmental, Rendena and Alpine Grey) that were housed in 41 multi-breed herds. Milk samples were analyzed for composition and SCC, while blood samples were analyzed for serum proteins (i.e. total protein, albumin, globulin and albumin-to-globulin ratio (A : G)). Herds were classified as low or high production, according to the cow's average daily milk energy yield adjusted for breed, days in milk (DIM) and parity. Data were analyzed using a linear mixed model that included the fixed effects of DIM, parity, SCS, breed, herd productivity and the random effect of the Herd-test date within productivity level. Cows in high producing herds (characterized also by greater use of concentrates in the diet) had greater serum albumin concentrations. Breed differences were reported for all traits, highlighting a possible genetic mechanism. The specialized breed Jersey and the two dual-purpose local breeds (Alpine Grey and Rendena) had the lowest globulin concentration and greatest A : G. Changes in serum proteins were observed through lactation. Total protein reached the highest concentration during the 4th month of lactation. Blood albumin increased with DIM following a quadratic pattern, while globulin decreased linearly. As a consequence, A : G increased linearly during lactation. Older cows had greater total protein and globulin concentrations, while albumin concentration seemed to be not particularly affected by age. A linear relationship between serum proteins and SCS was observed. High milk SCS was associated with greater total protein and globulin concentrations in blood. The rise in globulin concentration, together with a decrease in albumin concentrations, resulted in a decline in A : G as SCS of milk increased. In conclusion, such non-genetic factors must be considered to appropriately interpret serum proteins as potential animal welfare indicator and their evaluation represents an important first-step for future analysis based on the integration of metabolomics, genetic and genomic information for improving the robustness of dairy cows.
Sensitivity of mouse bioassay in clinical wound botulism.
Wheeler, Charlotte; Inami, Gregory; Mohle-Boetani, Janet; Vugia, Duc
2009-06-15
California has an ongoing epidemic of wound botulism (WB) among injection drug users (IDUs). We retrospectively studied a cohort of patients with WB and determined the sensitivity of the mouse bioassay-the gold standard laboratory test for confirmation of botulism-in verifying WB. We defined a clinical case of WB as an acute, bilateral, descending, flaccid paralysis starting with 1 cranial nerve palsies in an IDU with no other explainable diagnosis. We calculated the sensitivity of the mouse bioassay as the proportion of clinical WB cases that had positive serum toxin test results by mouse bioassay. We compared serum toxin-positive with serum toxin-negative patients. Of 73 patients with WB, 50 tested serum toxin positive, yielding a sensitivity of 68%. Serum toxin-positive patients did not differ significantly from serum toxin-negative patients with respect to demographic characteristics or injection drug use practices or in days from patient symptom onset to collection of specimens for testing. Patients did not differ significantly by clinical characteristics, except that serum toxin-positive patients were more likely than serum toxin-negative patients to have required mechanical ventilation during their hospital courses (74% vs. 43%; P = .01). In this study, the mouse bioassay failed to detect botulinum toxin in the serum samples of nearly one-third of IDUs with characteristic WB. Such patients should be considered to have probable WB. Physicians should be aware of the test's limitations and base their final diagnosis of suspected WB on clinical criteria when the mouse bioassay produces negative results.
Nanotechnology-Based Detection of Novel microRNAs for Early Diagnosis of Prostate Cancer
2016-08-01
1 AD _________________ AWARD NUMBER: W81XWH-15-1-0157 TITLE: Nanotechnology -Based Detection of Novel microRNAs for Early Diagnosis of Prostate...DATES COVERED 15 Jul 2015 - 14 Jul 2016 4. TITLE AND SUBTITLE Nanotechnology -Based Detection of Novel microRNAs for Early Diagnosis of Prostate Cancer...the expression level of deregulated miRNAs in mouse and human PCa tissues as well as serum samples using an advanced nanotechnology -based sensing
Stein, Cheryl R.; Wolff, Mary S.; Calafat, Antonia M.; Kato, Kayoko; Engel, Stephanie M.
2012-01-01
The extent to which polyfluoroalkyl compounds (PFCs) are detectable in amniotic fluid is unknown. Using paired samples from 28 women, we compared the concentration of 8 PFCs measured in serum, the standard matrix for assessing human exposure, amniotic fluid from routine amniocentesis, and urine. Perfluorooctanoate (PFOA), perfluorononanoate (PFNA), perfluorooctane sulfonate (PFOS), and perfluorohexane sulfonate (PFHxS) were detected in all maternal serum samples. The number of amniotic fluid samples with detectable concentrations differed by PFC (PFOA n=24; PFNA n=10; PFOS n=9; PFHxS n=4). The correlation coefficient between maternal serum and amniotic PFC levels varied considerably by PFC (PFOA ρ=0.64, p<0.001; PFNA ρ=0.05, p=0.9; PFOS ρ=0.76, p=0.01; PFHxS ρ=0.80, p=0.2). Using linear regression, PFOA appeared to be commonly detected in amniotic fluid if the serum concentration exceeded approximately 1.5 ng/mL whereas PFOS was rarely detected in amniotic fluid until the serum concentration was about 5.5 ng/mL. No PFCs were detected in urine. PMID:22613200
Pedrotti Moreira, Fernanda; Wiener, Carolina David; Jansen, Karen; Portela, Luis Valmor; Lara, Diogo R; Souza, Luciano Dias de Mattos; da Silva, Ricardo Azevedo; Oses, Jean Pierre
2018-06-15
The aim of this study was to evaluate the effect of childhood trauma in cytokine serum levels of individuals with MDD. This was a cross-sectional study population-based, with people aged 18 to 35. The Mini International Neuropsychiatric Interview (M.I.N.I) measured to current major depressive disorder (MDD). To evaluate traumatic experiences during childhood, the Childhood Trauma Questionnaire (CTQ) was applied. Serum TNF- α, IL-6 and IL-10 levels were measured by ELISA using a commercial kit. The total sample comprised 166 young adults, of these: 40.4% were subjects with MDD and childhood trauma and 59.6% were diagnosed with MDD without childhood trauma. In relation to serum interleukin levels, subjects with childhood trauma showed a significantly higher serum IL-6 (p = 0.013) and IL-10 levels (p = 0.022) to compare no childhood trauma. Subjects with childhood trauma was observed positive correlation between serum IL-6 and physical abuse (r = 0.232, p = 0.035) and emotional abuse (r = 0.460, p ≤ 0.001). Moreover, IL-10 were positive correlation with physical abuse (r = 0.258, p = 0.013). TNF- α was not associated with childhood trauma. Childhood maltreatment may result higher inflammation dysregulation in individuals with depression than individuals that no has childhood maltreatment. Copyright © 2018 Elsevier B.V. All rights reserved.
Is higher sodium intake associated with elevated systemic inflammation? A population-based study.
Fogarty, Andrew W; Lewis, Sarah A; McKeever, Tricia M; Britton, John R
2009-06-01
Observational epidemiologic studies have suggested that a low-sodium diet is associated with reduced mortality. The objective was to test the hypothesis that a higher dietary intake of sodium is associated with increased systemic inflammation--a potential risk factor for both cardiovascular disease and cancer. The study design consisted of a randomly selected, cross-sectional, population-based study of 2633 individuals surveyed in 1991, of whom 1597 participants provided paired urinary and blood samples permitting measurement of 24-h urinary sodium excretion and serum C-reactive protein (CRP) concentrations. The mean (+/-SD) 24-h sodium intake for the population was 177 +/- 69 mmol. In the basic model adjusted for age, sex, and smoking, higher levels of 24-h sodium excretion were directly associated with serum CRP, with an increase in serum CRP of 1.20 mg/L per 100-mmol increment in sodium excretion (95% CI: 1.11, 1.30). However, this association was reduced after adjustment for body mass index, with an increase in serum CRP of 1.06 mg/L per 100-mmol increment in sodium excretion (95% CI: -1.02, 1.15). We observed a linear association between an objective measure of sodium intake and serum CRP that may be influenced by confounding by body mass index. The magnitude of these associations suggests that dietary sodium consumption is unlikely to be an important modifiable risk factor for increased systemic inflammation.
Qamar, Ayesha; Hayat, Asma; Ahmad, Tariq Mahmood; Khan, Alamgir; Hasnat, Mohammad Najam Ul; Tahir, Sufyan
2018-04-01
To determine the diagnostic accuracy and cut-off values of serum cystatin C as early diagnostic biomarker of diabetic kidney disease. Cross-sectional analytical study. Department of Pathology, Army Medical College, Rawalpindi in collaboration with Endocrinology Department, Military Hospital (MH), Rawalpindi from November 2015 to November 2016. One hundred and nineteen diagnosed patients of type 2 diabetes mellitus were enrolled in the study from the outpatient Endocrinology Department of the MH Rawalpindi. Fifty disease-free controls were also included. Fasting blood samples of the patients and controls were analysed for creatinine by Jaffé's kinetic method and estimated GFR was calculated using MDRD-based equation for GFR. Serum cystatin C was estimated by quantitative turbidimetric method. Serum cystatin C was higher in the diabetic group (mean = 1.022 ±0.33 mg/dl) as compared to the control group (mean = 0.63 ±0.14 mg/dl). ROC curve analysis, keeping less than 60 ml/min/1.73 m2 GFR (CKD-MDRD based) as reference value of the stat variable/gold standard; revealed an area under the curve of 0.914 (95% CI 0.85-0.98) and at optimal sensitivity of 88.2% and specificity of 84.8% the established cut-off of serum cystatin C was 1.26 mg/L. Cystatin C is an accurate biomarker of diabetic kidney disease with good sensitivity and specificity.
NASA Astrophysics Data System (ADS)
Yan, Zhengyu; Niu, Qianqian; Mou, Mingyao; Wu, Yi; Liu, Xiaoxuan; Liao, Shenghua
2017-07-01
A facile strategy for detecting xanthine in serum samples by copper nanocluster (CuNCs) with high intrinsic peroxidase-like activity was reported. Firstly, a simple, mild and time-saving method for preparing CuNCs was developed, in which dithiothreitol (DTT) and bovine serum albumin (BSA) were used as reductant and stabilizer, respectively. The as-prepared CuNCs exhibited a fluorescence emission at 590 nm with a quantum yield (QY) of approximately 5.29%, the fluorescence intensity of the as-prepared CuNCs exhibited no considerable change when stored under ambient condition with the lifetime is 1.75 μs. Moreover, the as-prepared CuNCs exhibited high intrinsic peroxidase-like activity with lower K m ( K m = 8.90 × 10-6 mol L-1) for H2O2, which indicated that CuNCs have a higher affinity for H2O2. Compared with natural enzyme, the as-synthesized CuNCs are more catalytic stable over a wide range of pH (4.0 13.0) and temperature (4 80 °C). Finally, an indirect method for sensing xanthine was established because xanthine oxidase can catalyse the oxidation of xanthine to produce H2O2. Xanthine could be detected as low as 3.8 × 10-7 mol L-1 with a linear range from 5.0 × 10-7 to 1.0 × 10-4 mol L-1. These results proved that the proposed method is sensitive and accurate and could be successfully applied to the determination of xanthine in the serum sample with satisfaction.
Hustad, Steinar; Eussen, Simone; Midttun, Øivind; Ulvik, Arve; van de Kant, Puck M; Mørkrid, Lars; Gislefoss, Randi; Ueland, Per M
2012-02-01
Biomarkers and metabolites related to B vitamin function and one-carbon metabolism have been studied as predictors of chronic diseases in studies based on samples stored in biobanks. For most biomarkers, stability data are lacking or fragmentary. Degradation and accumulation kinetics of 32 biomarkers were determined at 23 °C in serum and plasma (EDTA, heparin, and citrate) collected from 16 individuals and stored for up to 8 days. In frozen serum (-25 °C), stability was studied cross-sectionally in 650 archival samples stored for up to 29 years. Concentration vs time curves were fitted to monoexponential, biexponential, linear, and nonlinear models. For many biomarkers, stability was highest in EDTA plasma. Storage effects were similar at room temperature and at -25 °C; notable exceptions were methionine, which could be recovered as methionine sulfoxide, and cystathionine, which decreased in frozen samples. Cobalamin, betaine, dimethylglycine, sarcosine, total homocysteine, total cysteine, tryptophan, asymetric and symmetric dimethyl argenine, creatinine, and methylmalonic acid were essentially stable under all conditions. Most B vitamins (folate and vitamins B2 and B6) were unstable; choline increased markedly, and some amino acids also increased, particularly in serum. The kynurenines showed variable stability. For many biomarkers, degradation (folate and flavin mononucleotide) or accumulation (pyridoxal, riboflavin, choline, amino acids) kinetics at room temperature were non-first order. Data on stability and deterioration kinetics for individual biomarkers are required to optimize procedures for handling serum and plasma, and for addressing preanalytical bias in epidemiological and clinical studies.
Ramos, Jose Tomas; Villar, Sonia; Bouza, Emilio; Bergon-Sendin, Elena; Perez Rivilla, Alfredo; Collados, Caridad Tapia; Andreu, Mariano; Reyes, Candelaria Santana; Campos-Herrero, María Isolina; de Heredia, Jon López; Herrera, María Cruz López; Alonso, Paloma Anguita; Pallás-Alonso, Carmen Rosa
2017-01-01
ABSTRACT An epidemiological, multicenter, noninterventional, observational case-control study was conducted to describe the performance of serum beta-d-glucan (BDG) and Candida PCR in blood, serum, and sterile samples for the diagnosis of invasive candidiasis (IC) in very-low-birth-weight (VLBW) preterm neonates and to compare these techniques with culture of samples from blood and other sterile sites. Seventeen centers participated in the study, and the number of episodes analyzed was 159. A total of 9 episodes of IC from 9 patients (7 confirmed and 2 probable) and 150 episodes of suspected sepsis from 117 controls were identified. The prevalence of IC was 5.7% (95% confidence interval [95% CI], 2.1 to 9.3). The mortality was significantly higher in episodes of IC (44.4%) than in the non-IC episodes (11.1%, P < 0.01). The sensitivity and specificity of the PCR performed on blood/serum samples were 87.5% and 81.6%, respectively. The sensitivity and specificity of the BDG results were lower (75.0% and 64.6%). For cases with negative culture results, the PCR and the BDG results were positive in 27 (17.4%) and 52 (33.5%) episodes, respectively. The presence of multiorgan failure, improvement with empirical antifungal therapy, thrombocytopenia, and Candida colonization were significantly associated (P < 0.01) with PCR or BDG positivity regardless of the results of the cultures. Serum BDG analysis and Candida PCR could be used as complementary diagnostic techniques to detect IC in VLBW neonates. PMID:28659321
Sureda-Vives, Macià; Morell-Garcia, Daniel; Rubio-Alaejos, Ana; Valiña, Laura; Robles, Juan; Bauça, Josep Miquel
2017-09-01
Osmolality reflects the concentration of all dissolved particles in a body fluid, and its measurement is routinely performed in clinical laboratories for the differential diagnosis of disorders related with the hydrolytic balance regulation, the renal function and in small-molecule poisonings. The aim of the study was to assess the stability of serum, plasma and urine osmolality through time and under different common storage conditions, including delayed centrifugation. Blood and urine samples were collected, and classified into different groups according to several preanalytical variables: serum or plasma lithium-heparin tubes; spun or unspun; stored at room temperature (RT), at 4°C or frozen at -21°C. Aliquots from each group were assayed over time, for up to 14days. Statistical differences were based on three different international performance criteria. Whole blood stability was higher in the presence of anticoagulant. Serum osmolality was stable for 2days at RT and 8days at 4°C, while plasma was less stable when refrigerated. Urine stability was 5days at RT, 4days at 4°C and >14days when frozen. Osmolality may be of great interest for the management of several conditions, such as in case of a delay in the clinical suspicion, or in case of problems in sample collection or processing. The ability to obtain reliable results for samples kept up to 14days also offers the possibility to retrospectively assess baseline values for patients which may require it. Copyright © 2017. Published by Elsevier Inc.
Honeychurch, Kevin C; Brooks, Joshua; Hart, John P
2016-01-15
This paper describes the development of an electrochemical assay based on screen-printed carbon sensors for the determination of clonazepam in serum and in wine. The cyclic voltammetric behaviour of the drug was investigated and the effects of pH and scan rate on the peak current and peak potential determined. Two reduction peaks were recorded on the initial negative going scan, which were considered to result from the 2e(-), 2 H(+) reduction of the 4,5-azomethine and from the 4e(-), 4 H(+) reduction of the 7-NO2 to a hydroxylamine. On the return positive going scan an oxidation peak was seen, which was considered to result from the 2e(-), 2 H(+) oxidation (O1) of the hydroxylamine to the corresponding nitroso species. At pH 11 the solution of clonazepam was found to turn from clear to yellow in colour and the voltammetric signal of the O1 oxidation process was found to be adsorptive in nature, this was exploited in the development of an adsorptive stripping voltammetric assay. Experimental conditions were then optimised for the differential pulse adsorptive voltammetric measurement of clonazepam in wine and serum samples. It was shown that these analyses could be performed on only 100µL of sample which was deposited on the sensor surface. Mean recoveries of 79.53% (%CV=9.88%) and 88.22% (%CV=14.1%) were calculated for wine fortified with 3.16µg/mL and serum fortified with 12.6µg/mL. Copyright © 2015 Elsevier B.V. All rights reserved.
Ameri, Mehrdad; Schnaars, Henry; Sibley, John; Honor, David
2011-01-01
The most widely used method for bilirubin concentration determination is the diazo method, which measures the color of azobilirubin. The vanadate oxidase method is based on oxidation of bilirubin to biliverdin by vanadate. The objective of this study was to compare total and direct bilirubin concentration ([Bt] and [Bd], respectively) determined by the diazo and vanadate oxidase methods in pooled serum samples from dogs, monkeys, and rats spiked with panels of different concentrations of bilirubin standards. Pooled serum samples from 40 dogs, 40 monkeys, and 60 rats were spiked with either ditaurine conjugates of bilirubin or a standard reference material. The results obtained from both assays were compared using Deming regression analysis. The intra- and interassay precision, expressed as a percentage of the coefficient of variation (%CV), was determined for [Bt] and [Bd], and the mean percentage of recovery was calculated. The vanadate oxidase method displayed an excellent correlation (r = 0.99-1.00) with the diazo method. Using Deming regression, there were minimal negative or positive constant and proportional biases for [Bt] and [Bd]. The precision studies revealed that the vanadate oxidase method has comparable between-run and within-run CVs to those of the diazo method. The recovery study demonstrated that the diazo method more closely approximates the expected values of [Bt]. In conclusion, the vanadate oxidase method is a simple and rapid method that can be employed as an alternative to the diazo method when interfering substances are present in the serum samples of dog, monkey, and rat.
Stanek, J F; Stich, R W; Dubey, J P; Reed, S M; Njoku, C J; Lindsay, D S; Schmall, L M; Johnson, G K; LaFave, B M; Saville, W J A
2003-11-28
Equine protozoal myeloencephalitis (EPM) is a serious neurologic disease in the horse most commonly caused by Sarcocystis neurona. The domestic cat (Felis domesticus) is an intermediate host for S. neurona. In the present study, nine farms, known to have prior clinically diagnosed cases of EPM and a resident cat population were identified and sampled accordingly. In addition to the farm cats sampled, samples were also collected from a mobile spay and neuter clinic. Overall, serum samples were collected in 2001 from 310 cats, with samples including barn, feral and inside/outside cats. Of these 310 samples, 35 were from nine horse farms. Horse serum samples were also collected and traps were set for opossums at each of the farms. The S. neurona direct agglutination test (SAT) was used for both the horse and cat serum samples (1:25 dilution). Fourteen of 35 (40%) cats sampled from horse farms had circulating S. neurona agglutinating antibodies. Twenty-seven of the 275 (10%) cats from the spay/neuter clinic also had detectable S. neurona antibodies. Overall, 115 of 123 (93%) horses tested positive for anti-S. neurona antibodies, with each farm having greater than a 75% exposure rate among sampled horses. Twenty-one opossums were trapped on seven of the nine farms. Eleven opossums had Sarcocystis sp. sporocysts, six of them were identified as S. neurona sporocysts based on bioassays in gamma-interferon gene knockout mice with each opossum representing a different farm. Demonstration of S. neurona agglutinating antibodies in domestic and feral cats corroborates previous research demonstrating feral cats to be naturally infected, and also suggests that cats can be frequently infected with S. neurona and serve as one of several natural intermediate hosts for S. neurona.
Gas chromatography-mass spectrometry of biofluids and extracts.
Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Yang, Yang; Kharbatia, Najeh M
2015-01-01
Gas chromatography-mass spectrometry (GC-MS) has been widely used in metabonomics analyses of biofluid samples. Biofluids provide a wealth of information about the metabolism of the whole body and from multiple regions of the body that can be used to study general health status and organ function. Blood serum and blood plasma, for example, can provide a comprehensive picture of the whole body, while urine can be used to monitor the function of the kidneys, and cerebrospinal fluid (CSF) will provide information about the status of the brain and central nervous system (CNS). Different methods have been developed for the extraction of metabolites from biofluids, these ranging from solvent extracts, acids, heat denaturation, and filtration. These methods vary widely in terms of efficiency of protein removal and in the number of metabolites extracted. Consequently, for all biofluid-based metabonomics studies, it is vital to optimize and standardize all steps of sample preparation, including initial extraction of metabolites. In this chapter, recommendations are made of the optimum experimental conditions for biofluid samples for GC-MS, with a particular focus on blood serum and plasma samples.
Prevalence of antibodies to Sarcocystis neurona and Neospora hughesi in horses from Mexico
USDA-ARS?s Scientific Manuscript database
The risk of equine protozoal myeloencephalitis (EPM) to horses in Mexico has not been established. Serum samples from 495 horses in Durango State, Mexico were examined for the presence of antibodies to Sarcocystis neurona and Neospora hughesi using enzyme-linked immunosorbent assays (ELISAs) based o...
Burns, Jennifer B.; Riley, Christopher B.; Shaw, R. Anthony; McClure, J. Trenton
2017-01-01
The objective of this study was to develop and compare the performance of laboratory grade and portable attenuated total reflectance infrared (ATR-IR) spectroscopic approaches in combination with partial least squares regression (PLSR) for the rapid quantification of alpaca serum IgG concentration, and the identification of low IgG (<1000 mg/dL), which is consistent with the diagnosis of failure of transfer of passive immunity (FTPI) in neonates. Serum samples (n = 175) collected from privately owned, healthy alpacas were tested by the reference method of radial immunodiffusion (RID) assay, and laboratory grade and portable ATR-IR spectrometers. Various pre-processing strategies were applied to the ATR-IR spectra that were linked to corresponding RID-IgG concentrations, and then randomly split into two sets: calibration (training) and test sets. PLSR was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. For the test set, the Pearson correlation coefficients between the IgG measured by RID and predicted by both laboratory grade and portable ATR-IR spectrometers was 0.91. The average differences between reference serum IgG concentrations and the two IR-based methods were 120.5 mg/dL and 71 mg/dL for the laboratory and portable ATR-IR-based assays, respectively. Adopting an IgG concentration <1000 mg/dL as the cut-point for FTPI cases, the sensitivity, specificity, and accuracy for identifying serum samples below this cut point by laboratory ATR-IR assay were 86, 100 and 98%, respectively (within the entire data set). Corresponding values for the portable ATR-IR assay were 95, 99 and 99%, respectively. These results suggest that the two different ATR-IR assays performed similarly for rapid qualitative evaluation of alpaca serum IgG and for diagnosis of IgG <1000 mg/dL, the portable ATR-IR spectrometer performed slightly better, and provides more flexibility for potential application in the field. PMID:28651006
Elsohaby, Ibrahim; Burns, Jennifer B; Riley, Christopher B; Shaw, R Anthony; McClure, J Trenton
2017-01-01
The objective of this study was to develop and compare the performance of laboratory grade and portable attenuated total reflectance infrared (ATR-IR) spectroscopic approaches in combination with partial least squares regression (PLSR) for the rapid quantification of alpaca serum IgG concentration, and the identification of low IgG (<1000 mg/dL), which is consistent with the diagnosis of failure of transfer of passive immunity (FTPI) in neonates. Serum samples (n = 175) collected from privately owned, healthy alpacas were tested by the reference method of radial immunodiffusion (RID) assay, and laboratory grade and portable ATR-IR spectrometers. Various pre-processing strategies were applied to the ATR-IR spectra that were linked to corresponding RID-IgG concentrations, and then randomly split into two sets: calibration (training) and test sets. PLSR was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. For the test set, the Pearson correlation coefficients between the IgG measured by RID and predicted by both laboratory grade and portable ATR-IR spectrometers was 0.91. The average differences between reference serum IgG concentrations and the two IR-based methods were 120.5 mg/dL and 71 mg/dL for the laboratory and portable ATR-IR-based assays, respectively. Adopting an IgG concentration <1000 mg/dL as the cut-point for FTPI cases, the sensitivity, specificity, and accuracy for identifying serum samples below this cut point by laboratory ATR-IR assay were 86, 100 and 98%, respectively (within the entire data set). Corresponding values for the portable ATR-IR assay were 95, 99 and 99%, respectively. These results suggest that the two different ATR-IR assays performed similarly for rapid qualitative evaluation of alpaca serum IgG and for diagnosis of IgG <1000 mg/dL, the portable ATR-IR spectrometer performed slightly better, and provides more flexibility for potential application in the field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saunders, G.C.
1977-01-01
A rapid enzyme-labeled antibody (ELA) microtechnique for the screening of swine for hog cholera antibodies was developed and evaluated with a blind study, using a 640-sample hog cholera serum bank. The total time to run a group of 22 samples was approximately 1 hour. The ELA test results correlated >99% with hog cholera serum-neutralization test results on the same serums. Test results also indicated that the ELA test shares with the hog cholera serum-neutralization test the problem of cross reactions between the antibodies of hog cholera and bovine viral diarrhea.
Moncrieff, J
1994-03-18
A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.
Vu, David M; Kelly, Dominic; Heath, Paul T; McCarthy, Noel D; Pollard, Andrew J; Granoff, Dan M
2006-07-15
Group C meningococcal conjugate-vaccine effectiveness in the United Kingdom declines from ~90% in the first year to 0% between 1 and 4 years after immunization in infants immunized at 2, 3, and 4 months of age and to 61% in toddlers given a single dose. Confidence intervals are wide, and the extent of protection is uncertain. Serum samples were obtained from children 3-5 years of age who were participants in a preschool booster-vaccine trial. Serum bactericidal activity was measured with human complement. Group C anticapsular antibody concentrations were measured by a radioantigen binding assay. Passive protection was analyzed in an infant rat bacteremia model. Serum samples from UK children who had been immunized 2-3 years earlier as infants or toddlers had higher levels of radioantigen binding, bactericidal activity, and passive protection than did historical control serum samples from unimmunized children (P<.05). A higher proportion of children immunized as infants had serum bactericidal activity titers > or =1 : 4 (considered to be protective) than those immunized as toddlers (61% vs. 24%; P<.01), but there were no significant differences in the proportion of serum samples conferring passive protection (50% and 41%, respectively; P=.4). We found no evidence of lower immunity in children immunized as infants than as toddlers. On the basis of serum bactericidal activity and/or passive protection, 40%-50% of both age groups are protected at 2-3 years after immunization, which was significantly greater than in unimmunized historical controls (<5%).
Low-serum GTA-446 anti-inflammatory fatty acid levels as a new risk factor for colon cancer.
Ritchie, Shawn A; Tonita, Jon; Alvi, Riaz; Lehotay, Denis; Elshoni, Hoda; Myat, Su-; McHattie, James; Goodenowe, Dayan B
2013-01-15
Gastrointestinal tract acid-446 (GTA-446) is a long-chain polyunsaturated fatty acid present in the serum. A reduction of GTA-446 levels in colorectal cancer (CRC) patients has been reported previously. Our study compared GTA-446 levels in subjects diagnosed with CRC at the time of colonoscopy to the general population. Serum samples and pathology data were collected from 4,923 representative subjects undergoing colonoscopy and from 964 subjects from the general population. Serum GTA-446 levels were determined using a triple-quadrupole tandem mass spectrometry method. A low-serum GTA-446 level was based on the bottom tenth percentile of subjects with low risk based on age (40-49 years old) in the general population. Eighty-six percent of newly diagnosed CRC subjects (87% for stages 0-II and 85% for stages III-IV) showed low-serum GTA-446 levels. A significant increase in the CRC incidence rate with age was observed in subjects with low GTA-446 levels (p = 0.019), but not in subjects with normal levels (p = 0.86). The relative risk of CRC given a low GTA-446 level was the highest for subjects under age 50 (10.1, 95% confidence interval [C.I.] = 6.4-16.4 in the reference population, and 7.7, 95% C.I. = 4.4-14.1 in the colonoscopy population, both p < 0.0001), and declined with age thereafter. The CRC incidence rate in subjects undergoing colonoscopy with low GTA-446 levels was over six times higher than for subjects with normal GTA-446 levels and twice that of subjects with gastrointestinal symptoms. The results show that a low-serum GTA-446 level is a significant risk factor for CRC, and a sensitive predictor of early-stage disease. Copyright © 2012 UICC.
Daily rhythm of salivary and serum urea concentration in sheep
Piccione, Giuseppe; Foà, Augusto; Bertolucci, Cristiano; Caola, Giovanni
2006-01-01
Background In domestic animals many biochemical and physiological processes exhibit daily rhythmicity. The aim of the present study was to investigate the rhythmic pattern of salivary and serum urea concentrations in sheep. Methods Six 3-year-old female sheep kept in the same environmental conditions were used. Sheep were sampled at 4 hour intervals for 48 consecutive hours starting at 08:00 of the first day and finishing at 04:00 of the second day. Blood samples were collected via intravenous cannulae inserted into the jugular vein; saliva samples were collected through a specific tube, the "Salivette". Salivary and serum urea concentrations were assayed by means of UV spectrophotometer. ANOVA was used to determine significant differences. The single Cosinor procedure was applied to the results showing significant differences over time. Results ANOVA showed a significant effect of time on salivary and serum urea concentrations. Serum and salivary urea peaked during the light phase. In the dark phase serum and salivary urea concentrations decreased, and the diurnal trough occurred at midnight. Cosinor analysis showed diurnal acrophases for salivary and serum urea concentrations. Daily mean levels were significantly higher in the serum than in the saliva. Conclusion In sheep both salivary and serum urea concentrations showed daily fluctuations. Urea is synthesized in the liver and its production is strongly influenced by food intake. Future investigation should clarify whether daily urea rhythms in sheep are endogenous or are simply the result of the temporal administration of food. PMID:17123442
Natsios, Athanasios; Vezakis, Antonios; Kaparos, Georgios; Fragulidis, Georgios; Karakostas, Nikolaos; Kouskouni, Evangelia; Logothetis, Emmanouil; Polydorou, Andreas
2015-01-01
Serum and bile tumor markers are under intense scrutiny for the diagnosis of malignant disease. The purpose of our study was to report the usefulness of serum and bile tumor markers for the discrimination between benign and malignant pancreatobiliary diseases. Between March 2010 and May 2013, 95 patients with obstructive jaundice or history of biliary obstruction, were included in the study. During ERCP, bile samples were obtained for measurement of tumor markers CEA, CA19- 9, CA125, CA72-4 and CA242. Serum samples were taken before ERCP for the same measurements. The patients were divided into two groups: patients with malignant disease and patients with benign disease. Serum tumor marker levels were significantly higher in patients with malignant disease. Serum CA242 and CA19-9 exhibited the highest diagnostic accuracy (76.8% and 73.7%, respectively). CA125 and CA72-4 levels in bile samples were significantly higher in patients with malignant disease. Bile CA125, CEA and CA72-4 achieved the best diagnostic accuracy (69, 65 and 65), respectively). The combined detection of CA19-9, CA242 in serum and CA125, CA72-4 in bile along with total bilirubin levels, showed the best diagnostic accuracy (81%). Serum and bile tumor markers, when studied alone, lack the diagnostic yield to discriminate benign from malignant pancreatobiliary diseases. In cases of diagnostic dilemmas the combination of serum and bile markers might be helpful.
Fox, Maureen; Brieva, Claudia; Moreno, Carlos; MacWilliams, Peter; Thomas, Chet
2008-12-01
The white-footed tamarin (Saguinus leucopus) is an endangered primate that lives in a small forest corridor in northern Colombia, South America. Hematologic and serum biochemistry reference values are important tools in evaluating the health of the white-footed tamarin and serve to promote the survival of this species. The purpose of this study was to establish diagnostically important hematologic and serum biochemistry reference values for healthy white-footed tamarins and to determine whether there was significant variation with respect to age class (juveniles, adults), gender, and housing facility. Blood samples were collected for hematologic and serum biochemistry measurements from 29 wild-caught captive tamarins during February and April 2005, housed at three different facilities in central Colombia. Hematology and serum biochemistry values were similar in adults and juveniles. Female white-footed tamarins had absolute reticulocyte counts that were lower than those of male tamarins and males had lower serum chloride concentrations than female tamarins. Mean values for hemoglobin, mean cell hemoglobin, serum total protein, albumin, glucose, and alkaline phosphatase varied among the three housing facilities. Twenty-two of the 29 tamarins sampled were microfilaria-positive and had significantly higher mean serum alkaline phosphatase concentrations. Among the 29 tamarins sampled in this study, serum values for mean alkaline phosphatase and creatine kinase concentrations were higher than reported values for other mammals. The reference intervals determined in this study were comparable to normal ranges reported for other members of the family Callitrichidae.
Hausmann, Jennifer C; Cray, Carolyn; Hartup, Barry K
2015-09-01
Protein electrophoresis of serum samples from endangered, wild whooping cranes ( Grus americana ) was performed to help assess the health of the only self-sustaining, migratory population in North America. Serum samples from wild adult cranes (n = 22) were taken at Aransas National Wildlife Refuge, Texas, USA during winter. Wild juvenile cranes (n = 26) were sampled at Wood Buffalo National Park, Northwest Territories, Canada, in midsummer. All captive crane samples were acquired from the International Crane Foundation, Baraboo, WI, USA. Captive adult cranes (n = 30) were sampled during annual examinations, and archived serum samples from captive juvenile cranes (n = 19) were selected to match the estimated age of wild juveniles. Wild juveniles had significantly lower concentrations of all protein fractions than wild adults, except for prealbumin and γ globulins. All protein fraction concentrations for wild juveniles were significantly lower compared with captive juveniles, except for prealbumin and γ globulins, which were higher. Wild adults had significantly greater γ globulin concentrations than captive adults. Captive juveniles had significantly lower prealbumin and albumin concentrations and albumin : globulin ratios than captive adults. The higher γ globulin concentrations in wild versus captive cranes are likely because of increased antigenic exposure and immune stimulation. Protein fraction concentrations vary significantly with age and natural history in this species. Reference intervals for serum protein electrophoresis results from captive adult whooping cranes are provided in this study.
Okay, Thelma Suely; Del Negro, Gilda Maria Barbaro; Yamamoto, Lídia; Raiz Júnior, Roberto
2005-01-01
Twenty-four whole blood and serum samples were drawn from an eight year-old heart transplant child during a 36 months follow-up. EBV serology was positive for VCA-IgM and IgG, and negative for EBNA-IgG at the age of five years old when the child presented with signs and symptoms suggestive of acute infectious mononucleosis. After 14 months, serological parameters were: positive VCA-IgG, EBNA-IgG and negative VCA-IgM. This serological pattern has been maintained since then even during episodes suggestive of EBV reactivation. PCR amplified a specific DNA fragment from the EBV gp220 (detection limit of 100 viral copies). All twenty-four whole blood samples yielded positive results by PCR, while 12 out of 24 serum samples were positive. We aimed at analyzing whether detection of EBV-DNA in serum samples by PCR was associated with overt disease as stated by the need of antiviral treatment and hospitalization. Statistical analysis showed agreement between the two parameters evidenced by the Kappa test (value 0.750; p < 0.001). We concluded that detection of EBV-DNA in serum samples of immunosuppressed patients might be used as a laboratory marker of active EBV disease when a Real-Time PCR or another quantitative method is not available.
Yang, Qian; Manicke, Nicholas E.; Wang, He; Petucci, Christopher; Cooks, R. Graham
2013-01-01
A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 μL of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R2>0.95) and reproducibility (RSD ~10 %) were achieved in the concentration ranges from 100 nM to 5 μM for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests. PMID:22760507
Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D
2013-12-01
Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, < Lower Limit of Quantitation (LLQ); range, < LLQ-43.3 mcg/mL). Significant differences and associations were identified between case status and the following: 1) serum oxalic acid and serum HEAA (both OR = 14.6; 95% C I = 2.8-100.9); 2) serum diglycolic acid and urine diglycolic acid (both OR > 999; exact p < 0.0001); and 3) urinary glycolic acid (OR = 0.057; 95% C I = 0.001-0.55). Two CSF sample results were excluded and two from the same case were averaged, yielding eight samples from eight cases. Diglycolic acid was detected in seven (88%) of case CSF samples (median, 2.03 mcg/mL; range, < LLQ, 7.47). Significantly elevated HEAA (serum) and diglycolic acid (serum and urine) concentrations were identified among cases, which is consistent with animal data. Low urinary glycolic acid concentrations in cases may have been due to concurrent AKI. Although serum glycolic concentrations among cases may have initially increased, further metabolism to oxalic acid may have occurred thereby explaining the similar glycolic acid concentrations in cases and controls. The increased serum oxalic acid concentration results in cases versus controls are consistent with this hypothesis. Diglycolic acid is associated with human DEG poisoning and may be a biomarker for poisoning. These findings add to animal data suggesting a possible role for traditional antidotal therapies. The detection of HEAA and diglycolic acid in the CSF of cases suggests a possible association with signs and symptoms of DEG-associated neurotoxicity. Further work characterizing the pathophysiology of DEG-associated neurotoxicity and the role of traditional toxic alcohol therapies such as fomepizole and hemodialysis is needed.
Serum and urine chromium as indices of chromium status in tannery workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Randall, J.A.; Gibson, R.S.
Serum and urinary Cr levels of a selected group of men exposed to CrIII in four Southern Ontario tanneries were compared with those of men not exposed to Cr. Fasted blood samples were obtained from 72 tannery workers (TW; mean age +/- SD = 36 +/- 12 years) and from 52 controls (CS; mean age +/- SD = 41 +/- 13 years). Serum Cr levels as determined by graphite furnace atomic absorption spectrophotometry were significantly higher (P = 0.0001) for TW (median 0.49 ng/ml, range 0.37-0.81) than for CS (median 0.15 ng/ml, range 0.12-0.20). Urine samples were collected from 49more » TW and 43 CS on a Friday pm and from 42 TW on a Monday am. Urinary creatine (Cre) was determined by the Jaffe reaction. For Friday samples, the median urinary Cr/Cre ratio was significantly higher (P = 0.0001) for TW (median 0.83 ng/mg, range 0.48-1.82) than for CS (median 0.18 ng/mg, range 0.13-0.26). For TW, Cr/Cre was correlated with serum Cr (r = 0.72, P = 0.0001). Neither urinary Cr/Cre nor serum Cr was correlated with length of employment in the tanning industry. There were significant differences in serum Cr levels and urinary Cr/Cre ratios among TW employed in different areas of the tanneries. For TW, the median urinary Cr/Cre ratio for Monday morning samples was significantly lower than for Friday afternoon samples (P = 0.03). These data indicate that CrIII is absorbed and that serum and urine Cr in tannery workers may be indices of Cr exposure and status.« less
Serum and urine chromium as indices of chromium status in tannery workers.
Randall, J A; Gibson, R S
1987-05-01
Serum and urinary Cr levels of a selected group of men exposed to CrIII in four Southern Ontario tanneries were compared with those of men not exposed to Cr. Fasted blood samples were obtained from 72 tannery workers (TW; mean age +/- SD = 36 +/- 12 years) and from 52 controls (CS; mean age +/- SD = 41 +/- 13 years). Serum Cr levels as determined by graphite furnace atomic absorption spectrophotometry were significantly higher (P = 0.0001) for TW (median 0.49 ng/ml, range 0.37-0.81) than for CS (median 0.15 ng/ml, range 0.12-0.20). Urine samples were collected from 49 TW and 43 CS on a Friday pm and from 42 TW on a Monday am. Urinary creatine (Cre) was determined by the Jaffe reaction. For Friday samples, the median urinary Cr/Cre ratio was significantly higher (P = 0.0001) for TW (median 0.83 ng/mg, range 0.48-1.82) than for CS (median 0.18 ng/mg, range 0.13-0.26). For TW, Cr/Cre was correlated with serum Cr (r = 0.72, P = 0.0001). Neither urinary Cr/Cre nor serum Cr was correlated with length of employment in the tanning industry. There were significant differences in serum Cr levels and urinary Cr/Cre ratios among TW employed in different areas of the tanneries. For TW, the median urinary Cr/Cre ratio for Monday morning samples was significantly lower than for Friday afternoon samples (P = 0.03). These data indicate that CrIII is absorbed and that serum and urine Cr in tannery workers may be indices of Cr exposure and status.
A novel and sensitive radioreceptor assay for serum melatonin levels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tenn, C.; Niles, L.
A simple and sensitive radioreceptor assay (RRA) has been developed to measure melatonin levels in serum. The assay is based on competition between 2-({sup 125}I)iodomelatonin (({sup 125}I)MEL) and melatonin for binding to high-affinity binding sites in chick forebrain. To measure the amount of melatonin present in a serum sample, it was extracted with dichloromethane and added to the assay medium. The percentage inhibition of radioligand binding in the presence of the extracted serum was determined and compared to the percent displacement by known amounts of melatonin in a standard curve. There was little or no cross-reactivity with other structurally relatedmore » compounds. The sensitivity of the assay is {approximately}1.5pg/0.15 mL and the intra- and inter-assay variations are approximately 8%. Since the RRA results are comparable to that of an established radioimmunoassay (RIA), it provides a sensitive and rapid alternative to the more time consuming RIA.« less
Chronic hepatitis C virus infection: Serum biomarkers in predicting liver damage
Valva, Pamela; Ríos, Daniela A; De Matteo, Elena; Preciado, Maria V
2016-01-01
Currently, a major clinical challenge in the management of the increasing number of hepatitis C virus (HCV) infected patients is determining the best means for evaluating liver impairment. Prognosis and treatment of chronic hepatitis C (CHC) are partly dependent on the assessment of histological activity, namely cell necrosis and inflammation, and the degree of liver fibrosis. These parameters can be provided by liver biopsy; however, in addition to the risks related to an invasive procedure, liver biopsy has been associated with sampling error mostly due to suboptimal biopsy size. To avoid these pitfalls, several markers have been proposed as non-invasive alternatives for the diagnosis of liver damage. Distinct approaches among the currently available non-invasive methods are (1) the physical ones based on imaging techniques; and (2) the biological ones based on serum biomarkers. In this review, we discuss these approaches with special focus on currently available non-invasive serum markers. We will discuss: (1) class I serum biomarkers individually and as combined panels, particularly those that mirror the metabolism of liver extracellular matrix turnover and/or fibrogenic cell changes; (2) class II biomarkers that are indirect serum markers and are based on the evaluation of common functional alterations in the liver; and (3) biomarkers of liver cell death, since hepatocyte apoptosis plays a significant role in the pathogenesis of HCV infection. We highlight in this review the evidence behind the use of these markers and assess the diagnostic accuracy as well as advantages, limitations, and application in clinical practice of each test for predicting liver damage in CHC. PMID:26819506
Kim, Jo-Il; Noh, Joo-Yoon; Kim, Mira; Park, Jong-Min; Song, Hyun-Woo; Kang, Min-Jung; Pyun, Jae-Chul
2017-08-01
Newborn screening for diagnosis of phenylketonuria, homocystinuria, and maple syrup urine disease have been conducted by analyzing the concentration of target amino acids using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) based on parylene-matrix chip. Parylene-matrix chip was applied to MALDI-ToF MS analysis reducing the matrix peaks significantly at low mass-to-charge ratio range (m/z < 500). Reproducibility of inter-spot and intra-spot analyses of amino acids was less than 10%. Methanol extraction was adopted for simple and rapid sample preparation of serum before mass spectrometric analysis showing 13.3 to 45% of extraction efficiency. Calibration curves for diagnosis of neonatal metabolic disorders were obtained by analyzing methanol-extracted serum spiked with target amino acids using MALDI-ToF MS. They showed good linearity (R 2 > 0.98) and the LODs were ranging from 9.0 to 22.9 μg/mL. Effect of proteins in serum was estimated by comparing MALDI-ToF mass spectra of amino acids-spiked serum before and after the methanol extraction. Interference of other amino acids on analysis of target analyte was determined to be insignificant. From these results, MALDI-ToF MS based on parylene-matrix chip could be applicable to medical diagnosis of neonatal metabolic disorders. Copyright © 2017 Elsevier Inc. All rights reserved.
Al Salmi, Issa; AlRukhaimi, Mona; AlSahow, Ali; Shaheen, Faisal A M; Al-Ghamdi, Saeed M G; AlAli, Fadwa; AlGhareeb, Sumaya; Al Maimani, Yacoub; AlGhonaim, Mohammed; Bieber, Brian; Tentori, Francesca; Pisoni, Ronald L
2016-11-01
The prospective cohort Dialysis Outcomes and Practice Patterns Study (DOPPS) initiated data collection in national samples of hemodialysis (HD) units (total of 41 study sites) in all six Gulf Cooperation Council (GCC) countries (Bahrain, Kuwait, Oman, Qatar, Saudi Arabia, and the United Arab Emirates) in late 2012. Here, we report initial results regarding mineral bone disorders (MBDs) and its management in the GCC countries. Forty-one randomly selected HD facilities, treating >23 HD patients each, were sampled and represent care for >95% of GCC HD patients. Descriptive results for the GCC countries based on a random sample of 20-30 HD patients in each study facility. Initial results for the GCC are from 931 HD patients treated at 41 dialysis units (ranging from 1 unit in Bahrain to 21 in Saudi Arabia). Results are presented as weighted estimates, accounting for the sampling fraction in each unit. Baseline descriptive statistics (e.g., mean, median, or percentage), weighted by facility sampling fraction were calculated for the study sample. For analyses examining the percent of facility patients having (a) serum phosphorus >6.0 mg/dL or (b) parathyroid hormone (PTH) >600 pg/mL, analyses were restricted to facilities having at least 10 HD patients with a reported serum phosphorus or PTH measurement, respectively. Logistic regression analyses of the indicated binary outcomes were based on the use of generalized estimating equations and were adjusted for GCC country, patient age category (<45 years, 45-65 years, and >65 years old), sex, and whether the patient was diagnosed with diabetes mellitus. Logistic models accounted for clustering of patients within facilities, assuming an exchangeable working correlation matrix. Mean age of HD patients in the GCC countries was 53 years vs. 61-64 years in the three other DOPPS regions. MBD markers showed slightly lower mean serum Calcium in the GCC countries, similar mean serum phosphorus, and intermediate median PTH levels compared with the three other DOPPS regions. Among GCC countries, the country mean value of MBD markers ranged from 8.6-9.0 mg/dL for serum calcium, 4.4-5.4 mg/dL for serum phosphorus, whereas median PTH ranged from 163-389 pg/mL. Similar to other DOPPS regions, PTH was higher among patients who were younger or without diabetes, and serum phosphorus was lower with older age (P <0.001 for each). History of parathyroidectomy was lower in the GCC countries versus other regions but did not differ when adjusted for age and dialysis vintage. Among treatments used for managing MBD, the GCC countries showed one of the highest uses of cinacalcet (24%) and phosphorus binder use (81%), whereas intravenous Vitamin D use (24%) was slightly higher than that in EURANZ. A much larger fraction of HD patients in the GCC countries had a dialysate calcium bath ≥3.5 mEq/L (43%) versus 0-4% in the three other DOPPS regions. Although many aspects of MBD management and MBD marker achievement are similar in the GCC countries to that seen in other DOPPS study regions, large variability was seen across countries and facilities in the GCC. Mean serum calcium was lower in the GCC despite the much greater use of dialysate Ca of ~3.5 mEq/L which may be due to the relatively low use of vitamin D and higher cinacalcet use, meriting further study. Future work will focus on GCC facility HD practices and patient characteristics most strongly related to the achievement of MBD target levels and associated outcomes.
Association between serum soluble CD30 and serum creatinine before and after renal transplantation.
López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M
2008-11-01
There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.
Zhong, Hui; Zhang, Wei; Qin, Min; Gou, ZhongPing; Feng, Ping
2017-06-01
Residual renal function needs to be assessed frequently in patients on continuous ambulatory peritoneal dialysis (CAPD). A commonly used method is to measure creatinine (Cr) and urea clearance in urine collected over 24 h, but collection can be cumbersome and difficult to manage. A faster, simpler alternative is to measure levels of cystatin C (CysC) in serum, but the accuracy and reliability of this method is controversial. Our study aims to validate published CysC-based equations for estimating residual renal function in patients on CAPD. Residual renal function was measured by calculating average clearance of urea and Cr in 24-h urine as well as by applying CysC- or Cr-based equations published by Hoek and Yang. We then compared the performance of the equations against the 24-h urine results. In our sample of 255 patients ages 47.9 ± 15.6 years, the serum CysC level was 6.43 ± 1.13 mg/L. Serum CysC level was not significantly associated with age, gender, height, weight, body mass index, hemoglobin, intact parathyroid hormone, normalized protein catabolic rate or the presence of diabetes. In contrast, serum CysC levels did correlate with peritoneal clearance of CysC and with levels of prealbumin and high-sensitivity C-reactive protein. Residual renal function was 2.56 ± 2.07 mL/min/1.73 m 2 based on 24-h urine sampling, compared with estimates (mL/min/1.73 m 2 ) of 2.98 ± 0.66 for Hoek's equation, 2.03 ± 0.97 for Yang's CysC-based equation and 2.70 ± 1.30 for Yang's Cr-based equation. Accuracies within 30%/50% of measured residual renal function for the three equations were 29.02/48.24, 34.90/56.86 and 31.37/54.90. The three equations for estimating residual renal function showed similar limits of agreement and differed significantly from the measured value. Published CysC-based equations do not appear to be particularly reliable for patients on CAPD. Further development and validation of CysC-based equations should take into account peritoneal clearance of CysC and other relevant factors. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Skibinska, A; Lee, A; Wylie, M; Smyth, V J; Welsh, M D; Todd, D
2015-01-01
The development of an indirect enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of Group B chicken astrovirus (CAstV) infections is described. The test was based on the use of an affinity-purified capsid antigen, specific to CAstV isolate 11672, produced as a glutathione-S-transferase N-terminal fusion protein by a recombinant baculovirus. Strongly positive ELISA signals were elicited against experimentally produced antisera raised to CAstVs from Group B (subgroups i and ii) but were negative for antisera raised to a Group A CAstV. Using a panel of 240 selected serum samples, 99% agreement was observed when the results obtained by ELISA were compared to those from an indirect immunofluorescence test for CAstV 11672. The ELISA test was applied to 68 serum sets comprising 1864 samples, which were obtained from parent and grandparent flocks originating mainly in the UK. Of the 52 sets containing ELISA-positive samples, 24 sets had >75% samples positive and nine sets had <25% samples positive and were regarded as having high and low seropositivities, respectively. Of the 1864 serum samples tested 1090 (58.5%) were ELISA positive and of these, 234 sera (21.5%) produced strongly positive signals, whereas moderately positive and weakly positive signals were produced by 562 (51.5%) and 294 (27%) sera. When used for flock screening purposes, this ELISA test can be used to (i) investigate the occurrence of first-time CAstV infections of parent flocks during lay and the possible adverse effects caused by vertically transmitted CAstV infections on broiler hatchability and performance and (ii) diagnose Group B CAstV infections within specific pathogen free flocks.
Adams, Hayley; van Vuuren, Moritz; Kania, Stephen; Bosman, Anna-Mari; Keet, Dewald; New, John; Kennedy, Melissa
2010-12-01
Feline immunodeficiency virus (FIV) is a lentivirus in the Retroviridae family that causes lifelong infection in domestic cats. The lentivirus of African lions (Panthera leo), referred to as FIVple, is endemic in certain lion populations in eastern and southern Africa. Lentivirus infection leads to immunologic dysfunction and immunosuppressive disease in domestic cats; however, little is known about the pathogenic effects of infection in lions, nor about the epidemiologic impact on free-ranging and captive populations. Whole blood and serum samples were collected opportunistically from free-ranging lions in Kruger National Park, Republic of South Africa (RSA). Whole blood and serum samples were also collected from captive wild lions in the RSA. A nested polymerase chain reaction (PCR) assay for detection of FIV was performed on all whole blood samples. In addition, serum samples were tested for cross-reactive antibodies to domestic feline lentivirus antigens and puma lentivirus synthetic envelope peptide antigen. The PCR assay successfully amplified the lion lentivirus from African lions. The relative sensitivity and relative specificity were 79% and 100%, respectively, and the positive and negative predictive values were 100% and 67%, respectively. This research represents the first study to compare genetic material with antibody-based methods of lentivirus detection on lions in RSA. Using PCR as an additional diagnostic test for FIV in lions will increase screening sensitivity and will allow viral characterization among circulating isolates and monitoring of changes in the viral epidemiology within geographic regions and populations over time.
Kumar, Roshan M; Pajanivel, R; Koteeswaran, G; Menon, Surendra K; Charles, Pravin Mv
2017-01-01
Asthma is a chronic inflammatory disorder of the airway with involvement of various cellular populations and release of many inflammatory mediators. Eosinophils and serum immunoglobulin E (IgE) are considered a good marker of airway inflammation in asthma. The correlation of clinical assessment with various markers of airway inflammation in asthma is not well established in the Indian population. This study aims to study the correlation of serum IgE, sputum eosinophil count, and peripheral eosinophil count with clinical severity of Asthma. This is a cross-sectional study involving 76 stable asthmatic patients of 18-60 years of age attending the pulmonary medicine OPD. Spirometry measured at baseline. Participants were categorized according to the GINA criteria based on clinical symptoms and pulmonary function test. Blood samples were collected for peripheral eosinophil count, serum IgE levels, and sputum samples for eosinophil count. All three parameters were compared with severity of asthma. The correlation of sputum eosinophil count, peripheral eosinophil count, and serum IgE with severity of asthma was analyzed by Pearson's Chi-square test, Fisher's exact test, and the correlation coefficient was reported together with standard error of the estimate. The mean age of patients in our study was 37.42 years and 56.6% were male. There was a significant inverse correlation between serum IgE levels and predicted forced expiratory volume 1 s (FEV1). Sputum eosinophilia was significantly seen in severe persistent asthma patients (19.7%). There was a significant inverse correlation between sputum eosinophil count and predicted FEV1and forced vital capacity. We also found there was a significant association between peripheral eosinophil count, sputum eosinophil count, and elevated serum IgE (g100 IU/mL) with severe persistent asthma. The assessment of sputum eosinophil count is simple, inexpensive, noninvasive, and direct measurement of airway inflammation. It could be the preferred method in monitoring airway inflammation and guided management in day-to-day practice.
Sayed-Hassan, Rima; Abazid, Nizar; Alourfi, Zaynab
2014-01-01
Vitamin D deficiency (25-hydroxyvitamin D (25OHD) <25 nmol/L) was common in a convenience sample of apparently healthy Syrian adults. Female gender, season, and concealing clothing were independent predictors of vitamin D deficiency. Community-based research is needed to identify vulnerable subgroups and inform public health actions. Optimal vitamin D status for bone health has been inferred from the determination of serum 25OHD levels below which there is an increase in serum parathyroid hormone (PTH). Studies worldwide showed high prevalence of hypovitaminosis D even in sunny countries. There is little evidence about its prevalence among Syrian adult population. We aimed to assess the serum levels of 25OHD and factors related to vitamin D inadequacy and its relation to serum PTH and calcium among apparently healthy adults. Serum 25OHD and PTH measurements were obtained from 372 subjects aged 18-62 years living in Damascus and its surroundings, between April 2011 and March 2013. Binary logistic regression was used to assess risk factors for hypovitaminosis D. The mean (standard deviation (SD)) 25OHD level was 24.7 (16.9) nmol/L [9.8 (6.7) ng/mL] and was higher in men than women (p < 0.001). Levels <25, <50, and <75 nmol/L were detected in 61, 90.1, and 99.2 % of the participants, respectively. Season influenced vitamin D status in men but not in women (p < 0.001). Female gender and wearing the veil (hijab) were independent predictors of vitamin D deficiency (25OHD <25 nmol/L). PTH was significantly higher below this threshold (p < 0.001). Serum 25OHD <25 nmol/L, sex, and age ≥ 35 years were statistically significant factors for PTH elevation. Vitamin D deficiency was highly prevalent in our sample. Further research is needed to identify population groups vulnerable for hypovitaminosis D and specify its predictors and inform the necessary public health measures.
Burse, V W; Groce, D F; Caudill, S P; Korver, M P; Phillips, D L; McClure, P C; Lapeza, C R; Head, S L; Miller, D T; Buckley, D J
1994-04-29
We measured the residues of polychlorinated biphenyls (PCBs) in the serum of 23 residents of the New Bedford, Massachusetts, area and from two homogenates each of bluefish and lobsters from the same area. We used congener-specific and total Aroclor quantitative approaches, both of which involved gas chromatography with electron capture detection. Using gas chromatography mass spectrometry (electron ionization mode), we confirmed the presence of PCBs in the combined serum samples and in the aliquots of bluefish and lobsters. In measuring the PCB levels in serum, we found good agreement between the two electron capture detector approaches (r > or = 0.97) when the serum of specific congeners was compared to total Aroclor. We used univariate and multivariate quality control approaches to monitor these analyses. Analytical results for bluefish showed a better agreement between the two techniques than did those for lobsters; however, the small number of samples precluded any statistical comparison. We also measured levels of chlorinated pesticides in the serum samples of two groups of New Bedford residents, those with low PCB levels (< 15 ng/ml) and those with high PCB levels (> or = 15 ng/ml). We found that residents with high PCB levels also tended to have higher levels of hexachlorobenzene (HCB) and 1,1-dichloro-2,2-di-(p-chlorophenyl) ethylene (p,p'-DDE). The higher concentration of all three analytes appears to be influenced by employment in the capacitor industry, by seafood consumption, or both. Using Jaccard measures of similarity and principal component analysis we compared the gas chromatographic patterns of PCBs found in the serum of New Bedford area residents with high serum PCBs with the patterns found in homogenates of lobsters (inclusive of all edible portions except the roe), in homogenates of bluefish fillets taken from local waters, and in serum from goats fed selected technical Aroclors (e.g. Aroclors 1016, 1242, 1254, or 1260). The patterns found in human serum samples were similar to the patterns found in lobster homogenates. Both of these patterns closely resembled patterns found in the serum samples of the goat fed aroclor 1254, as demonstrated by both pattern recognition techniques. In addition, the chromatographic patterns of human serum and of lobsters and bluefish homogenates all indicated the presence of PCBs more characteristic of Aroclors 1016 or 1242.
Polychlorinated biphenyls in umbilical cord serum of newborns from Rio Grande do Sul state, Brazil.
Mohr, Susana; Sifuentes dos Santos, Joice; Schwanz, Thiago Guilherme; Wagner, Roger; Mozzaquatro, Joseane Oliveira; Lorenzoni, Alessandra Scherer; Costabeber, Ijoni Hilda
2015-12-07
Polychlorinated biphenyls (PCBs) are food-chain contaminants that have been shown to contaminate foods worldwide. The newborn are exposed to these organochlorine compounds across the placenta and through breastfeeding. They are proven to be carcinogenic and may contribute to congenital malformation etiology. This study examined levels of five PCB congeners (28, 52, 138, 153 and 180) in umbilical cord serum samples from 148 newborns from Rio Grande do Sul state, Brazil. Serum concentrations of PCBs were analyzed by gas chromatography with electron capture detection and mass spectrometry. Levels of ∑PCBs ranged from 0.35 to 55.17 ng/ml in umbilical cord serum positive samples, and PCB 138 was the most prevalent congener. Only 7.4% of samples presented no PCB congener. Some PCB congener cord serum levels were related to the locale of the mothers' residence, smoking and drinking habits, fruit consumption, and congenital malformation. Copyright © 2015 Elsevier B.V. All rights reserved.
Loeffler, David A; Klaver, Andrea C
2017-11-01
Specific antibody concentrations are frequently measured in serum (and plasma and intravenous immunoglobulin) samples by enzyme-linked immunosorbent assay (ELISA). The standard negative control involves incubation of buffer alone on antigen-coated wells. The immunoreactivity that develops in antigen-coated wells in which diluted serum has been incubated is assumed to represent specific antibody binding. This approach can result in marked overestimation of specific antibody levels, because serum contains specific polyvalent antibodies which bind, primarily with low affinity, to multiple antigens (including those on ELISA plates) despite the use of blocking agents. Non-denaturing purification of serum IgG, followed by assessment of the antigen binding or antigen-binding affinity of this purified IgG, can reduce but not eliminate the problem of polyvalent antibody binding in indirect ELISAs. Alternatively, polyvalent antibody binding can be estimated by incubating a diluted serum sample on wells coated with an irrelevant protein (such as bovine serum albumin or a scrambled peptide sequence) or buffer alone, then subtracting this reactivity from the sample's binding to wells coated with the antigen of interest. Polyvalent binding of immunoglobulins must be accounted for in order to obtain accurate ELISA measurements of serum, plasma, or intravenous immunoglobulin antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao
2017-11-27
Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.
Biomonitoring Hexamethylene Diisocyanate (HDI) Exposure Based on Serum Levels of HDI-Specific IgG
Wisnewski, Adam V.; Stowe, Meredith H.; Nerlinger, Abby; Opare-addo, Paul; Decamp, David; Kleinsmith, Christopher R.; Redlich, Carrie A.
2012-01-01
Objectives: Isocyanate chemicals essential for polyurethane production are widely used industrially, and are increasingly found in consumer products. Asthma and other adverse health effects of isocyanates are well-documented and exposure surveillance is crucial to disease prevention. Hexamethylene diisocyanate (HDI)-specific serum immunoglobulin G (IgG) was evaluated as an exposure biomarker among workers at a US Air Force Air Logistics Center, which includes a large aircraft maintenance facility. Methods: HDI-specific IgG (HDI-IgG) titers in serum samples (n = 74) were measured using an enzyme-linked immunosorbent assay based upon the biuret form of HDI conjugated to human albumin. Information on personal protective equipment (PPE), work location/tasks, smoking, asthma history, basic demographics, and HDI skin exposure was obtained through questionnaire. Results: HDI-specific serum IgG levels were elevated in n = 17 (23%) of the workers studied. The prevalence and/or end-titer of the HDI-IgG was significantly (P < 0.05) associated with specific job titles, self-reported skin exposure, night-shift work, and respirator use, but not atopy, asthma, or other demographic information. The highest titers were localized to specific worksites (C-130 painting), while other worksites (generator painting) had no or few workers with detectable HDI-IgG. Conclusions: HDI-specific immune responses (IgG) provide a practical biomarker to aid in exposure surveillance and ongoing industrial hygiene efforts. The strategy may supplement current air sampling approaches, which do not assess exposures via skin, or variability in PPE use or effectiveness. The approach may also be applicable to evaluating isocyanate exposures in other settings, and may extend to other chemical allergens. PMID:22449630
Poor micronutrient intake and status is a public health problem among adolescent Mozambican girls.
Korkalo, Liisa; Freese, Riitta; Alfthan, Georg; Fidalgo, Lourdes; Mutanen, Marja
2015-08-01
Micronutrient deficiencies can damage the health of adolescent girls and their offspring. There is a lack of population-based data on the micronutrient status of adolescents in Sub-Saharan Africa. We conducted a cross-sectional, population-based study to examine the biochemical status, prevalence of deficiency, dietary intake, and food sources of selected micronutrients among adolescent girls in Central Mozambique. Separate groups of study participants were recruited in 2 seasons in 2010. The participants were girls between 14 and 19 years of age (n = 551) from 1 urban area and 2 rural districts. Micronutrient status indicators were analyzed from blood and urine samples. Twenty-four-hour dietary recalls were also carried out. The overall prevalence with 95% confidence interval (calculated using sampling weights) among nonpregnant girls was 42.4% (37.2%-47.8%; n = 466) for anemia, 27.4% (23.1%-32.2%; n = 427) for low serum ferritin, 32.7% (27.7%-38.1%; n = 423) for low serum zinc, 14.7% (11.2%-19.0%; n = 426) for low plasma retinol, and 4.1% (2.9%-5.8%; n = 448) for low serum folate. The selenium status was considered sufficient. Mild to moderate iodine deficiency was found in the rural districts, whereas the iodine status of urban girls was adequate. Significantly lower serum folate concentrations were found in the urban area compared to the rural districts. The seasonal differences in vitamin A intake were significant. The intakes of micronutrients from animal source foods were small. In summary, adolescent Mozambican girls are at risk of several micronutrient deficiencies. This raises concern especially because adolescent motherhood is common in the region. Actions need to be taken to prevent and control micronutrient deficiencies. Copyright © 2015 Elsevier Inc. All rights reserved.
Estrella, Michelle M.; Astor, Brad C.; Köttgen, Anna; Selvin, Elizabeth; Coresh, Josef; Parekh, Rulan S.
2010-01-01
Background. Anaemia worsens as kidney function declines. Both conditions are associated with increased mortality. Serum cystatin C is purportedly a more sensitive marker of kidney disease and a better predictor of mortality than serum creatinine. However, studies suggest that extrarenal factors also influence cystatin C levels. Methods. We determined whether estimates of glomerular filtration rate [estimated glomerular filtration rate (eGFR)] based on serum cystatin C alone or in combination with serum creatinine were superior to those based on serum creatinine in recognizing impaired kidney function in the setting of anaemia in a sub-sample of the Third National Health and Nutrition Examination Survey of the USA consisting of 6734 participants, 20 years or older. Results. The prevalence of moderate to severe kidney disease (eGFR 15–59 mL/min/1.73 m2) among anaemic persons was 15–16% when based on serum creatinine alone (eGFRSCR) or combined with cystatin C (eGFRSCR + CYSC); this estimate increased to nearly 25% when kidney function was estimated by cystatin C (eGFRCYSC). The adjusted odds ratios of kidney disease in anaemic versus non-anaemic persons were slightly higher with eGFRCYSC than eGFRSCR and eGFRSCR + CYSC in younger adults [odds ratio (OR) = 5.22, 95% confidence interval (CI): 2.23, 12.17], women (OR = 5.34, 95% CI: 2.36, 12.06) and those with elevated C-reactive protein (CRP) (OR = 7.36, 95% CI: 1.98–27.36). Conclusions. Impaired kidney function was common in individuals with anaemia. Among anaemic individuals, the prevalence estimate for kidney disease was notably higher when kidney function was estimated by cystatin C alone compared with the estimations by serum creatinine alone or in combination with serum cystatin C. eGFRCYSC may be particularly helpful in identifying kidney disease in the setting of anaemia among younger persons, women and those with elevated CRP. Regardless of which renal biomarker is used, our study suggests that an evaluation for underlying kidney disease should be considered in the standard workup of anaemia. PMID:20176612
Tharwat, Mohamed; Al-Sobayil, Fahd
2014-03-12
The effect of digoxin administration on the serum concentration of the cardiac troponin I (cTnI) has not been reported to date in equidae. This study was therefore designed to evaluate the effect of digoxin on cardiac cell damage in donkeys (Equus asinus) as assessed by cTnI, acid-base and electrolyte balance and haematobiochemical profiles. Ten clinically healthy donkeys were given an IV infusion of digoxin at a dose of 14 μg/kg. Blood samples were collected from the donkeys up through 72 h post-injection. Three of the donkeys exhibited increased heart and respiratory rates post-injection. In the other seven animals, the heart and respiratory rates were lower 4 h post-injection. The serum digoxin concentration increased significantly at many time points after injection. The serum concentration of cTnI did not differ significantly between pre- and post-injection. An increase in blood pH was noted at 3 h after digoxin injection. There were also increases in PO2 and in oxygen saturation. Decreases in PCO2 at 2 to 48 h post-injection as well as a decrease in blood lactate at 4 h post-injection were observed. The serum concentration of glucose remained significantly elevated at all-time points after digoxin injection. It is concluded that administration of digoxin to healthy donkeys (14 μg/kg) did not result in elevations of serum cTnI concentration, signs of digoxin intoxication, ECG abnormalities and did not increase serum concentrations of blood urea nitrogen and creatinine.
Talarico, Sarah; Safaeian, Mahboobeh; Gonzalez, Paula; Hildesheim, Allan; Herrero, Rolando; Porras, Carolina; Cortes, Bernal; Larson, Ann; Fang, Ferric C; Salama, Nina R
2016-08-01
Epidemiologic studies of the carcinogenic stomach bacterium Helicobacter pylori have been limited by the lack of noninvasive detection and genotyping methods. We developed a new stool-based method for detection, quantification, and partial genotyping of H. pylori using droplet digital PCR (ddPCR), which allows for increased sensitivity and absolute quantification by PCR partitioning. Stool-based ddPCR assays for H. pylori 16S gene detection and cagA virulence gene typing were tested using a collection of 50 matched stool and serum samples from Costa Rican volunteers and 29 H. pylori stool antigen-tested stool samples collected at a US hospital. The stool-based H. pylori 16S ddPCR assay had a sensitivity of 84% and 100% and a specificity of 100% and 71% compared to serology and stool antigen tests, respectively. The stool-based cagA genotyping assay detected cagA in 22 (88%) of 25 stools from CagA antibody-positive individuals and four (16%) of 25 stools from CagA antibody-negative individuals from Costa Rica. All 26 of these samples had a Western-type cagA allele. Presence of serum CagA antibodies was correlated with a significantly higher load of H. pylori in the stool. The stool-based ddPCR assays are a sensitive, noninvasive method for detection, quantification, and partial genotyping of H. pylori. The quantitative nature of ddPCR-based H. pylori detection revealed significant variation in bacterial load among individuals that correlates with presence of the cagA virulence gene. These stool-based ddPCR assays will facilitate future population-based epidemiologic studies of this important human pathogen. © 2015 John Wiley & Sons Ltd.
Pradeep, A. R.; Agarwal, Esha; Bajaj, Pavan; Rao, Nishanth S.
2013-01-01
Objective: Chronic periodontitis (CP) is a common, chronic inflammatory disease initiated by bacteria, which has an increased prevalence and severity in patients with type 2 diabetes mellitus (t2 DM). A variety of reactive oxygen species are able to cause direct damage to proteins, deoxyribonucleic acid, carbohydrates and lipids. Lipid peroxidation is always combined with the formation of reactive aldehydes like 4-Hydroxy-2-nonenal (HNE). The purpose of this study was to determine the presence of the HNE-His adducts levels in serum and gingival crevicular fluid (GCF) in t2 DM among CP subjects and to find an association, if any. Materials and Methods: A total of 40 subjects (20 males and 20 females) were selected based on their clinical parameters into three groups: Group 1 (10 healthy), Group 2 (15 subjects, CP without t2 DM), Group 3 (15 subjects, CP with t2 DM). Serum and GCF samples were collected to estimate the levels of the HNE-His adducts by the enzyme linked immunosorbent assay. Results: The mean HNE-His adducts concentration both in serum and GCF was highest for Group 3 followed by Group 2 and least in Group 1. Conclusions: All samples in each group tested positive for HNE-His adducts assay. Serum and GCF HNE-His adducts concentration both in t2 DM with CP and non-diabetic CP subjects were higher than the healthy controls. Further large scale longitudinal studies should be carried out to confirm positive correlations. PMID:24124291
Facca, Bryan; Frame, Bill; Triesenberg, Steve
1998-01-01
Ceftizoxime is a widely used beta-lactam antimicrobial agent, but pharmacokinetic data for use with clinically ill patients are lacking. We studied the population pharmacokinetics of ceftizoxime in 72 clinically ill patients at a community-based, university-affiliated hospital. A population pharmacokinetic model for ceftizoxime was created by using a prospective observational design. Ceftizoxime was administered by continuous infusion to treat patients with proven or suspected bacterial infections. While the patients were receiving infusions of ceftizoxime, serum samples were collected for pharmacokinetic analysis with the nonlinear mixed-effect modeling program NONMEM. In addition to clearance and volume of distribution, various comorbidities were examined for their influence on the kinetics. All 72 subjects completed the study, and 114 serum samples were collected. Several demographic and comorbidity variables, namely, age, weight, serum creatinine levels, congestive heart failure, and long-term ventilator dependency, had a significant impact on the estimate for ceftizoxime clearance. A mixture model, or two populations for estimation of ceftizoxime clearance, was discovered. One population presented with an additive clearance component of 1.6 liters per h. In addition, a maximizer function for serum creatinine levels was found. In summary, two models for ceftizoxime clearance, mixture and nonmixture, were found and are presented. Clearance for ceftizoxime can be estimated with commonly available clinical information and the models presented. From the clearance estimates, the dose of ceftizoxime to maintain the desired concentration in serum can be determined. Work is needed to validate the model for drug clearance and to evaluate its predictive performance. PMID:9661021
Association between serum antibodies to periodontal bacteria and rheumatoid factor in NHANES III
Goh, Charlene E.; Kopp, Jacob; Papapanou, Panos N.; Molitor, Jerry A.; Demmer, Ryan T.
2016-01-01
Objective Alterations in the microbiome, including the periodontal microbiome, may be a risk factor for rheumatoid arthritis (RA). Most studies that have analyzed this association are relatively small, focus primarily on a single periodontal pathogen (Porphyromonas gingivalis), and are not population-based. We investigated the association between elevated serum IgG antibodies to 19 periodontal species and the prevalence of rheumatoid factor (RF) in a large nationally representative sample of adults. Methods The Third National Health and Nutrition Examination Survey is a cross-sectional sample of the non-institutionalized US population (n=33,994). Our study population included all dentate participants ≥60 years, who did not have RA as defined by a modified version of the American College of Rheumatology 1987 criteria, and had complete data for both serum IgG antibodies against periodontal bacteria and serum RF antibody titer (n=2461). Results Adjusted odds ratios (ORs) (95% CI) summarizing the relationship between the 19 periodontal serum IgGs and RF seropositivity ranged from 0.53 (0.29, 0.97) to 1.27 (0.79, 2.06), and 17 of the 19 observed ORs were < 1.0. The ORs for RF seropositivity among participants with elevated Prevotella intermedia [0.53 (0.29, 0.97)] and Capnocytophaga ochracea [0.54 (0.31, 0.95)] IgG were statistically significant. Conclusion We have found elevated periodontal IgGs to be mostly unassociated with RF seropositivity in the nationally representative NHANES III. Elevated antibody levels to P. intermedia and C. ochracea were associated with lower odds of RF seropositivity. PMID:27110949
Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma
2017-08-01
Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p<0.005), whereas for patients having cholesterol and mixed GS the concentrations were on the lower side. Biliary Ca concentrations of patients were found to be higher than controls, but difference was significant for pigmented GS patients (p>0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of GS. Copyright © 2017 Elsevier B.V. All rights reserved.
Nie, Jianhui; Wang, Wenbo; Wen, Zhiheng; Song, Aijing; Hong, Kunxue; Lu, Shan; Zhong, Ping; Xu, Jianqing; Kong, Wei; Li, Jingyun; Shang, Hong; Ling, Hong; Ruan, Li; Wang, Youchun
2012-11-01
Among the neutralizing antibody evaluation assays, the single-cycle pseudovirus infection assay is high-throughput and can provide rapid, sensitive and reproducible measurements after a single cycle of infection. Cell counts, pseudovirus inoculation levels, amount of diethylaminoethyl-dextran (DEAE-dextran), and the nonspecific effects of serum and plasma were tested to identify the optimal conditions for a neutralizing antibody assay based on pseudoviruses. Optimal conditions for cell counts, pseudovirus inoculation, and amount of DEAE-dextran were 1 × 10(4)cells/well, 200TCID(50)/well, and 15 μg/ml, respectively. Compared with serum samples, high-concentration anticoagulants reduced the relative light unit (RLU) value. The RLU value increased sharply initially but then decreased slowly with dilution of the plasma sample. Test kits containing 10 HIV-1 CRF07/08_BC pseudovirus strains and 10 plasma samples from individuals infected with HIV-1 CRF07/08_BC were assembled into two packages and distributed to nine laboratories with a standard operating procedure included. For the 10 laboratories that evaluated the test, 17 of 44 (37%) laboratory pairs were considered equivalent. A statistical qualification rule was developed based on the testing results from 5 experienced laboratories, where a laboratory qualified if at least 83% of values lied within the acceptable range. Copyright © 2012 Elsevier B.V. All rights reserved.
Hou, Li; Cui, Yuling; Xu, Mingdi; Gao, Zhuangqiang; Huang, Jianxin; Tang, Dianping
2013-09-15
A new sandwich-type impedimetric immunosensor based on functionalized graphene oxide nanosheets with a high ratio of horseradish peroxidase (HRP) and detection antibody was developed for the detection of carcinoembryonic antigen (CEA) by coupling with enzymatic biocatalytic precipitation of 4-chloro-1-naphthol (4-CN) on the captured antibody-modified glassy carbon electrode. Two molecular tags (with and without the graphene oxide nanosheets) were investigated for the detection of CEA and improved analytical features were acquired with the graphene-based labeling. With the labeling method, the performance and factors influencing the properties of the impedimetric immunosensors were also studied and evaluated. Under the optimal conditions, the dynamic concentration range of the impedimetric immunosensors spanned from 1.0pgmL(-1) to 80ngmL(-1) CEA with a detection limit (LOD) of 0.64pgmL(-1). Intra- and inter-assay coefficients of variation were less than 7.5% and 11%, respectively. Additionally, the methodology was evaluated for CEA analysis of 10 clinical serum samples and 5 diluted serum samples, receiving in a good accordance with the results obtained by the impedimetric immunoassay and the commercialized electrochemiluminescent method. Copyright © 2013 Elsevier B.V. All rights reserved.
Oberhauser, Felix; Kornhuber, Johannes; Wiltfang, Jens; Fassbender, Klaus; Schroeter, Matthias L.; Volk, Alexander E.; Diehl-Schmid, Janine; Prudlo, Johannes; Danek, Adrian; Landwehrmeyer, Bernhard; Lauer, Martin; Otto, Markus; Jahn, Holger
2018-01-01
Information on circulating miRNAs in frontotemporal lobar degeneration is very limited and conflicting results have complicated an interpretation in Alzheimer’s disease thus far. In the present study we I) collected samples from multiple clinical centers across Germany, II) defined 3 homogenous patient groups with high sample sizes (bvFTD n = 48, AD n = 48 and cognitively healthy controls n = 44), III) compared expression levels in both CSF and serum samples and IV) detected a limited set of miRNAs by using a MIQE compliant protocol based on SYBR-green miRCURY assays that have proven reliable to generate reproducible results. We included several quality controls that identified and reduced technical variation to increase the reliability of our data. We showed that the expression levels of circulating miRNAs measured in CSF did not correlate with levels in serum. Using cluster analysis we found expression pattern in serum that, in part, reflects the genomic organization and affiliation to a specific miRNA family and that were specifically altered in bvFTD, AD, and control groups. Applying factor analysis we identified a 3-factor model characterized by a miRNA signature that explained 80% of the variance classifying healthy controls with 97%, bvFTD with 77% and AD with 72% accuracy. MANOVA confirmed signals like miR-320a and miR-26b-5p at BH corrected significance that contributed most to discriminate bvFTD cases with 96% sensitivity and 90% specificity and AD cases with 89% sensitivity and specificity compared to healthy controls, respectively. Correlation analysis revealed that miRNAs from the 3-factor model also correlated with levels of protein biomarker amyloid-beta1-42 and phosphorylated neurofilament heavy chain, indicating their potential role in the monitoring of progressive neuronal degeneration. Our data show that miRNAs can be reproducibly measured in serum and CSF without pre-amplification and that serum includes higher expressed signals that demonstrate an overall better ability to classify bvFTD, AD and healthy controls compared to signals detected in CSF. PMID:29746584
Watanabe, Miki; Roth, Terri L; Bauer, Stuart J; Lane, Adam; Romick-Rosendale, Lindsey E
2016-01-01
A variety of wildlife species maintained in captivity are susceptible to iron storage disease (ISD), or hemochromatosis, a disease resulting from the deposition of excess iron into insoluble iron clusters in soft tissue. Sumatran rhinoceros (Dicerorhinus sumatrensis) is one of the rhinoceros species that has evolutionarily adapted to a low-iron diet and is susceptible to iron overload. Hemosiderosis is reported at necropsy in many African black and Sumatran rhinoceroses but only a small number of animals reportedly die from hemochromatosis. The underlying cause and reasons for differences in susceptibility to hemochromatosis within the taxon remains unclear. Although serum ferritin concentrations have been useful in monitoring the progression of ISD in many species, there is some question regarding their value in diagnosing hemochromatosis in the Sumatran rhino. To investigate the metabolic changes during the development of hemochromatosis and possibly increase our understanding of its progression and individual susceptibility differences, the serum metabolome from a Sumatran rhinoceros was investigated by nuclear magnetic resonance (NMR)-based metabolomics. The study involved samples from female rhinoceros at the Cincinnati Zoo (n = 3), including two animals that died from liver failure caused by ISD, and the Sungai Dusun Rhinoceros Conservation Centre in Peninsular Malaysia (n = 4). Principal component analysis was performed to visually and statistically compare the metabolic profiles of the healthy animals. The results indicated that significant differences were present between the animals at the zoo and the animals in the conservation center. A comparison of the 43 serum metabolomes of three zoo rhinoceros showed two distinct groupings, healthy (n = 30) and unhealthy (n = 13). A total of eighteen altered metabolites were identified in healthy versus unhealthy samples. Results strongly suggest that NMR-based metabolomics is a valuable tool for animal health monitoring and may provide insight into the progression of this and other insidious diseases.
Li, Yuanpeng; Li, Fucui; Yang, Xinhao; Guo, Liu; Huang, Furong; Chen, Zhenqiang; Chen, Xingdan; Zheng, Shifu
2018-08-05
A rapid quantitative analysis model for determining the glycated albumin (GA) content based on Attenuated total reflectance (ATR)-Fourier transform infrared spectroscopy (FTIR) combining with linear SiPLS and nonlinear SVM has been developed. Firstly, the real GA content in human serum was determined by GA enzymatic method, meanwhile, the ATR-FTIR spectra of serum samples from the population of health examination were obtained. The spectral data of the whole spectra mid-infrared region (4000-600 cm -1 ) and GA's characteristic region (1800-800 cm -1 ) were used as the research object of quantitative analysis. Secondly, several preprocessing steps including first derivative, second derivative, variable standardization and spectral normalization, were performed. Lastly, quantitative analysis regression models were established by using SiPLS and SVM respectively. The SiPLS modeling results are as follows: root mean square error of cross validation (RMSECV T ) = 0.523 g/L, calibration coefficient (R C ) = 0.937, Root Mean Square Error of Prediction (RMSEP T ) = 0.787 g/L, and prediction coefficient (R P ) = 0.938. The SVM modeling results are as follows: RMSECV T = 0.0048 g/L, R C = 0.998, RMSEP T = 0.442 g/L, and R p = 0.916. The results indicated that the model performance was improved significantly after preprocessing and optimization of characteristic regions. While modeling performance of nonlinear SVM was considerably better than that of linear SiPLS. Hence, the quantitative analysis model for GA in human serum based on ATR-FTIR combined with SiPLS and SVM is effective. And it does not need sample preprocessing while being characterized by simple operations and high time efficiency, providing a rapid and accurate method for GA content determination. Copyright © 2018 Elsevier B.V. All rights reserved.
Hansen, Jessica; Slechta, E. Susan; Gates-Hollingsworth, Marcellene A.; Neary, Brandon; Barker, Adam P.; Bauman, Sean; Kozel, Thomas R.
2013-01-01
Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results. PMID:23114703
Hansen, Jessica; Slechta, E Susan; Gates-Hollingsworth, Marcellene A; Neary, Brandon; Barker, Adam P; Bauman, Sean; Kozel, Thomas R; Hanson, Kimberly E
2013-01-01
Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results.
Biocompatible hydrogel membranes for the protection of RNA aptamer-based electrochemical sensors
NASA Astrophysics Data System (ADS)
Schoukroun-Barnes, Lauren R.; Wagan, Samiullah; Liu, Juan; Leach, Jennie B.; White, Ryan J.
2013-05-01
Electrochemical-aptamer based (E-AB) sensors represent a universal specific, selective, and sensitive sensing platform for the detection of small molecule targets. Their specific detection abilities are afforded by oligonucleotide (RNA or DNA) aptamers employed as electrode-bound biorecognition elements. Sensor signaling is predicated on bindinginduced changes in conformation and/or flexibility of the aptamer that is readily measurable electrochemically. While sensors fabricated using DNA aptamers can achieve specific and selective detection even in unadulterated sample matrices, such as blood serum, RNA-based sensors fail when challenged in the same sample matrix without significant sample pretreatment. This failure is at least partially a result of enzymatic degradation of the RNA sensing element. This degradation destroys the sensing aptamer inhibiting the quantitative measurement of the target analyte and thus limits the application of E-AB sensors constructed with RNA aptamer. To circumvent this, we demonstrate that a biocompatible hydrogel membrane protects the RNA aptamer sensor surface from enzymatic degradation for at least 3 hours - a remarkable improvement over the rapid (~minutes) degradation of unprotected sensors. To demonstrate this, we characterize the response of sensors fabricated with representative DNA and RNA aptamers directed against the aminoglycoside antibiotic, tobramycin in blood serum both protected and unprotected by a polyacrylamide membrane. Furthermore, we find encapsulation of the sensor surface with the hydrogel does not significantly impede the detection ability of aptamer-based sensors. This hydrogel-aptamer interface will thus likely prove useful for the long-term monitoring of therapeutics in complex biological media.
Xia, Xiaoyan; Carroll-Haddad, Alesia; Brown, Nicole; Utell, Mark J.; Mallon, Timothy; Hopke, Philip K.
2016-01-01
Objective The objectives were: 1) measure polycyclic aromatic hydrocarbons (PAHs), polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in 100 μL of human serum and 2) assess PAH and PCDD/PCDF as markers of burn pit exposures during military deployments. Methods PAHs and PCDDs/PCDFs were analyzed in 100μL serum samples collected pre- and post-deployment from 200 persons deployed to Iraq or Afghanistan (CASE); 200 persons not deployed (CONTROL) with GC/MS. Results Naphthalene was found in ~83% of the samples and was statistically different between post-deployment CASE personnel and pre-deployment. 1,2,3,4,6,7,8-Heptachlorodibenzo-p-dioxin, Octachlorodibenzo-p-dioxin, 1,2,3,7,8,9-Hexachlorodibenzofuran, and 1,2,3,4,6,7,8-Heptachlorodibenzofuran were found in ~38% of samples. Concentrations were significantly different between CASE and CONTROL and between pre- and post-deployment samples. Conclusions PAH and PCDD/PCDF in serum can serve as exposure markers and measurements in small volumes is feasible for quantifying exposure to burn pits. PMID:27501107
Jara, Rocio F.; Sepúlveda, Carolina; Ip, Hon S.; Samuel, Michael D.
2015-01-01
Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.
Jara, Rocío F; Sepúlveda, Carolina; Ip, Hon S; Samuel, Michael D
2015-04-01
Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.
Kawanishi, Noriaki; Kato, Yuki; Yokozeki, Kyosuke; Sawada, Shuji; Sakurai, Ryota; Fujiwara, Yoshinori; Shinkai, Shoji; Goda, Nobuhito; Suzuki, Katsuhiko
2018-06-06
Aging is known to be associated with increased risk of lipid disorders related to the development of type 2 diabetes. Recent evidence revealed that change of lipid molecule species in blood is associated with the risk of type 2 diabetes. However, changes in lipid molecular species induced by aging are still unknown. We assessed the effects of age on the serum levels of lipid molecular species as determined by lipidomics analysis. Serum samples were collected from ten elderly men (71.7 ± 0.5 years old) and women (70.2 ± 1.0 years old), ten young men (23.9 ± 0.4 years old), and women (23.9 ± 0.7 years old). Serum levels of lipid molecular species were determined by liquid chromatography mass spectrometry-based lipidomics analysis. Our mass spectrometry analysis revealed increases in the levels of multiple triacylglycerol molecular species in the serum of elderly men and women. Moreover, serum levels of total ester-linked phosphatidylcholine (PC) and phosphatidylethanolamine (PE) were increased by aging. In contrast, serum levels of specific ether-linked PC and PE molecular species were lower in elderly individuals than in young individuals. Our finding indicates that specific lipid molecular species, such as ether- and ester- linked phospholipids, may be selectively altered by aging.
Seasonal influence over serum and urine metabolic markers in submariners during prolonged patrols
Holy, Xavier; Bégot, Laurent; Renault, Sylvie; Butigieg, Xavier; André, Catherine; Bonneau, Dominique; Savourey, Gustave; Collombet, Jean-Marc
2015-01-01
Within the framework of earlier publications, we have consistently dedicated our investigations to eliciting the effects of both seasonal vitamin D deficiency and submarine-induced hypercapnia on serum parameters for acid–base balance and bone metabolism in submariners over a 2-month winter (WP) or summer (SP) patrols. The latest findings reported herein, contribute further evidence with regard to overall physiological regulations in the same submariner populations that underwent past scrutiny. Hence, urine and blood samples were collected in WP and SP submariners at control prepatrol time as well as on submarine patrol days 20, 41, and 58. Several urine and serum metabolic markers were quantified, namely, deoxypyridinoline (DPD), lactate, albumin, creatinine, nonesterified fatty acids (NEFA), and ionized sodium (Na+) or potassium (K+), with a view to assessing bone, muscle, liver, or kidney metabolisms. We evidenced bone metabolism alteration (urine DPD, calcium, and phosphorus) previously recorded in submarine crewmembers under prolonged patrols. We also highlighted transitory modifications in liver metabolism (serum albumin) occurring within the first 20 days of submersion. We further evidenced changes in submariners’ renal physiology (serum creatinine) throughout the entire patrol time span. Measurements of ionic homeostasis (serum Na+ and K+) displayed potential seasonal impact over active ionic pumps in submariners. Finally, there is some evidence that submersion provides beneficial conditions prone to fend off seasonal lactic acidosis (serum lactate) detected in WP submariners. PMID:26265754
Serum progranulin levels in relation to insulin resistance in childhood obesity.
Alissa, Eman M; Sutaih, Rima H; Kamfar, Hayat Z; Alagha, Abdulmoeen E; Marzouki, Zuhair M
2017-11-27
Progranulin is an adipokine that is involved in the inflammatory response, glucose metabolism, insulin resistance, and may therefore be involved in chronic subclinical inflammation associated with the pathogenesis of childhood obesity. We aimed to investigate the association of circulating progranulin levels with metabolic parameters in children and to assess the importance of progranulin as a biomarker for metabolic diseases. A total of 150 children were consecutively recruited from the Pediatric Nutrition Clinics at King Abdulaziz University Hospital in Jeddah, Saudi Arabia. Children were classified into four groups based on quartile for serum progranulin. Anthropometric variables were measured in all study subjects. Fasting blood samples were collected for measurement of blood glucose, insulin and lipid profile. Children within the upper quartile for serum progranulin concentration were heavier, more insulin resistant and had higher concentrations of serum total cholesterol, triglycerides, insulin and high sensitivity C reactive protein compared to those in the lower quartile. On correlation analysis, serum progranulin concentrations were significantly related to general and central adiposity, metabolic parameters, markers of inflammation and insulin resistance. Stepwise multiple regression showed that 26.6% of the variability in serum progranulin could be explained by measures of adiposity. The increased serum progranulin concentrations were closely related to measures of adiposity, metabolic parameters, inflammatory marker and insulin resistance indices, suggesting that progranulin may be an excellent biomarker for obesity in childhood.
Park, Seung-Gwon; Lee, Yong-Jin; Ham, Jung-Oh; Jang, Eun-Chul; Kim, Seong-Woo; Park, Hyun
2014-01-01
The present study investigated the association between long working hours and serum gamma-glutamyltransferase (GGT) levels, a factor influencing the incidence of cardiovascular disease. Data from the fifth Korean National Health and Nutrition Examination Survey (2010-2011) were used to analyze 1,809 women. Subjects were divided into three groups based on the number of weekly working hours: ≤29, 30-51, and ≥52 hours per week. Complex samples logistic regression was performed after adjusting for general and occupational factors to determine the association between long working hours and high serum GGT levels. The prevalence of high serum GGT levels in groups with ≤29, 30-51, and ≥52 working hours per week was 22.0%, 16.9%, and 26.6%, respectively. Even after adjusting for general and occupational factors, those working 30-51 hours per week had the lowest prevalence of high serum GGT levels. Compared to those working 30-51 hours per week, the odds ratios (OR) of having high serum GGT levels in the groups with ≥52 and ≤29 working hours per week were 1.56 (95% confidence interval [CI], 1.10-2.23) and 1.53 (95% CI, 1.05-2.24), respectively. Long working hours were significantly associated with high serum GGT levels in Korean women.
Pradeep, A R; Manjunath, R G Shiva; Kathariya, Rahul
2010-11-01
Increased C-reactive protein levels have been found in all active inflammations, including periodontitis. This study aims to assess the C-reactive protein levels in periodontal disease progression. Forty-five patients were divided into the following three groups (n=15) based on gingival index, probing pocket depth, and clinical attachment level: healthy (group I), gingivitis (group II), and chronic periodontitis (group III). Gingival crevicular fluid and serum samples were quantified for C-reactive protein using enzyme-linked immunosorbent assay. The mean C-reactive protein concentration in gingival crevicular fluid and serum was found to be highest in group III (1233.33ng/mL for gingival crevicular fluid, 5483.33ng/mL for serum), and least in group I (60 ng/mL and 413 ng/mL for gingival crevicular fluid and serum, respectively) The mean C-reactive protein concentration in group II (453.33ng/mL for gingival crevicular fluid and 3565.33 ng/mL for serum) was found to be intermediate. C-reactive protein levels in gingival crevicular fluid and serum increased proportionately with the severity of periodontal disease. They correlated positively with clinical parameters, including gingival index, probing pocket depth, and clinical attachment level. Thus, it can be considered as a periodontal inflammatory biomarker and deserves further consideration. © 2010 Blackwell Publishing Asia Pty Ltd.
Akiyama, Tomoyuki; Hayashi, Yumiko; Hanaoka, Yoshiyuki; Shibata, Takashi; Akiyama, Mari; Tsuchiya, Hiroki; Yamaguchi, Tokito; Kobayashi, Katsuhiro
2017-09-01
We quantified pyridoxal 5'-phosphate (PLP), pyridoxal (PL), and 4-pyridoxic acid (PA) in paired serum and cerebrospinal fluid (CSF) samples from children and investigated the effect of age on the concentrations and CSF-to-serum ratios of these vitamers. Serum and CSF samples prospectively collected from 49 pediatric patients were analyzed. PLP, PL, and PA were measured using high-performance liquid chromatography with fluorescence detection, using pre-column derivatization by semicarbazide. Effects of age on these vitamers, the PLP-to-PL ratio, CSF-to-serum PLP ratio, and CSF-to-serum PL ratio were evaluated using correlation analysis. The PLP, PL, and PA concentrations in the serum and CSF were higher at younger ages, except for CSF PA concentrations that were mostly below the limit of detection (<1.2nmol/l). The PLP-to-PL ratios in the serum and CSF correlated positively with age. The CSF-to-serum PLP ratio and CSF-to-serum PL ratio were independent of age. Age-related changes in PLP, PL, and PA in serum and in CSF from pediatric patients and CSF-to-serum ratios of PLP and PL demonstrated in this study will provide valuable information for evaluating PLP supply to the central nervous system from the peripheral blood. Copyright © 2017 Elsevier B.V. All rights reserved.
Cheadle, M A; Lindsay, D S; Greiner, E C
2006-06-01
Serum was collected from laboratory-reared Virginia opossums (Didelphis virginiana) to determine whether experimentally infected opossums shedding Sarcocystis neurona sporocysts develop serum antibodies to S. neurona merozoite antigens. Three opossums were fed muscles from nine-banded armadillos (Dasypus novemcinctus), and 5 were fed muscles from striped skunks (Mephitis mephitis). Serum was also collected from 26 automobile-killed opossums to determine whether antibodies to S. neurona were present in these opossums. Serum was analyzed using the S. neurona direct agglutination test (SAT). The SAT was modified for use with a filter paper collection system. Antibodies to S. neurona were not detected in any of the serum samples from opossums, indicating that infection in the opossum is localized in the small intestine. Antibodies to S. neurona were detected in filter-paper-processed serum samples from 2 armadillos naturally infected with S. neurona.