Stringer, Kathleen A.; Younger, John G.; McHugh, Cora; Yeomans, Larisa; Finkel, Michael A.; Puskarich, Michael A.; Jones, Alan E.; Trexel, Julie; Karnovsky, Alla
2015-01-01
Serum is a common sample of convenience for metabolomics studies. Its processing time can be lengthy and may result in the loss of metabolites including those of red blood cells (RBC). Unlike serum, whole blood (WB) is quickly processed, minimizing the influence of variable hemolysis while including RBC metabolites. To determine differences between serum and WB metabolomes, both sample types, collected from healthy volunteers, were assayed by 1H-NMR spectroscopy. A total of 34 and 50 aqueous metabolites were quantified from serum and WB, respectively. Free hemoglobin (Hgb) levels in serum were measured and the correlation between Hgb and metabolite concentrations was determined. All metabolites detected in serum were at higher concentrations in WB with the exception of acetoacetate and propylene glycol. The 18 unique metabolites of WB included adenosine, AMP, ADP and ATP, which are associated with RBC metabolism. The use of serum results in the underrepresentation of a number of metabolic pathways including branched chain amino acid degradation and glycolysis and gluconeogenesis. The range of free Hgb in serum was 0.03-0.01 g/dL and 8 metabolites were associated (p ≤ 0.05) with free Hgb. The range of free Hgb in serum samples from 18 sepsis patients was 0.02-0.46 g/dL. WB and serum have unique aqueous metabolite profiles but the use of serum may introduce potential pathway bias. Use of WB for metabolomics may be particularly important for studies in diseases like sepsis in which RBC metabolism is altered and mechanical and sepsis-induced hemolysis contributes to variance in the metabolome. PMID:26009817
Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A
2006-06-01
To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.
Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc
1998-01-01
A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372
Iron and ADHD: Time to Move beyond Serum Ferritin Levels
ERIC Educational Resources Information Center
Donfrancesco, Renato; Parisi, Pasquale; Vanacore, Nicola; Martines, Francesca; Sargentini, Vittorio; Cortese, Samuele
2013-01-01
Objective: (a) To compare serum ferritin levels in a sample of stimulant-naive children with ADHD and matched controls and (b) to assess the association of serum ferritin to ADHD symptoms severity, ADHD subtypes, and IQ. Method: The ADHD and the control groups included 101 and 93 children, respectively. Serum ferritin levels were determined with…
Antibodies against MERS coronavirus in dromedary camels, United Arab Emirates, 2003 and 2013.
Meyer, Benjamin; Müller, Marcel A; Corman, Victor M; Reusken, Chantal B E M; Ritz, Daniel; Godeke, Gert-Jan; Lattwein, Erik; Kallies, Stephan; Siemens, Artem; van Beek, Janko; Drexler, Jan F; Muth, Doreen; Bosch, Berend-Jan; Wernery, Ulrich; Koopmans, Marion P G; Wernery, Renate; Drosten, Christian
2014-04-01
Middle East respiratory syndrome coronavirus (MERS-CoV) has caused an ongoing outbreak of severe acute respiratory tract infection in humans in the Arabian Peninsula since 2012. Dromedary camels have been implicated as possible viral reservoirs. We used serologic assays to analyze 651 dromedary camel serum samples from the United Arab Emirates; 151 of 651 samples were obtained in 2003, well before onset of the current epidemic, and 500 serum samples were obtained in 2013. Recombinant spike protein-specific immunofluorescence and virus neutralization tests enabled clear discrimination between MERS-CoV and bovine CoV infections. Most (632/651, 97.1%) camels had antibodies against MERS-CoV. This result included all 151 serum samples obtained in 2003. Most (389/651, 59.8%) serum samples had MERS-CoV-neutralizing antibody titers >1,280. Dromedary camels from the United Arab Emirates were infected at high rates with MERS-CoV or a closely related, probably conspecific, virus long before the first human MERS cases.
Effect of storage duration on cytokine stability in human serum and plasma.
Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James
2018-06-14
Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ehresman, David J.; Froehlich, John W.; Olsen, Geary W.
2007-02-15
Interest in human exposure to perfluorinated acids, including perfluorobutanesulfonate (PFBS), perfluorohexanesulfonate (PFHS), perfluorooctanesulfonate (PFOS), and perfluorooctanoate (PFOA) has led to their measurement in whole blood, plasma and serum. Comparison of measurements in these different blood-based matrices, however, has not been rigorously investigated to allow for across-matrix comparisons. This research evaluated concentrations of PFBS, PFHS, PFOS, and PFOA in whole blood collected in heparin (lithium) and ethylenediamine tetraacetic acid (EDTA), plasma samples collected in heparin and EDTA, and serum (from whole blood allowed to clot). Blood samples were collected from 18 voluntary participants employed at 3M Company. Solid phase extraction methodsmore » were used for all analytical sample preparations, and analyses were completed using high-pressure liquid chromatography/tandem mass spectrometry methods. Serum concentrations ranged from: limit of quantitation (LOQ, 5 ng/mL) to 25 ng/mL for PFBS; LOQ (5 ng/mL) to 75 ng/mL for PFHS; LOQ (5 ng/mL) to 880 ng/mL for PFOS; and LOQ (5 or 10 ng/mL) to 7320 ng/mL for PFOA. Values less than the LOQ were not included in the statistical analyses of the mean of the ratios of individual values for the matrices. PFBS was not quantifiable in most samples. Serum to plasma ratios for PFHS, PFOS, and PFOA were 1:1 and this ratio was independent of the level of concentrations measured. Serum or plasma to whole blood ratios, regardless of the anticoagulant used, approximated 2:1. The difference between plasma and serum and whole blood corresponded to volume displacement by red blood cells, suggesting that the fluorochemicals are not found intracellularly or attached to the red blood cells.« less
The WHI offers an opportunity to evaluate ovarian cancer markers and screening decision rules developed and validated in EDRN CVC Studies 2 and 3 in women who were not being screened. It is particularly well suited to validation of risk markers, since many serum samples were drawn well before clinical diagnosis of cancer in the WHI cohorts. A strategy is needed to identify from among the general population of women over the age of 50 those at high-risk for a diagnosis of ovarian/fallopian tube cancer so that they can be referred for appropriate surveillance, imaging or surgical consult. Tools to identify high-risk women will be investigated including serum markers CA125, HE4, MSLN, and MMP7 and epidemiologic risk factors. We will optimize decision rules using stored serum samples from the WHI OS and conduct a simulated prospective validation using stored serum samples from the WHI CT. Decision rules to select women for ovarian cancer screening will be investigated as well as decision rules for use in ovarian cancer screening.
Serum factors and clinical characteristics associated with serum E-Screen activity
Wang, Jue; Trentham-Dietz, Amy; Hemming, Jocelyn D. C.; Hedman, Curtis J.; Sprague, Brian L.
2013-01-01
Background The E-Screen bioassay can measure the mitogenicity of human serum and thus may be useful as a biomarker in epidemiologic studies of breast cancer. While the assay’s MCF-7 cells are known to proliferate in response to estrogen, the specific determinants of variation in E-Screen activity in human serum samples are poorly understood. We sought to identify serum molecules and patient characteristics associated with serum E-Screen activity among postmenopausal women. Methods Postmenopausal women (N=219) aged 55–70 with no history of postmenopausal hormone use or breast cancer completed a questionnaire and provided a blood sample. Serum was analyzed for E-Screen activity and a variety of molecules including sex hormones, growth factors, and environmental chemicals. Stepwise selection procedures were used to identify correlates of E-Screen activity. Results Serum samples from all women had detectable E-Screen activity, with a median estradiol equivalents value of 0.027 ng/mL and interquartile range of 0.018–0.036 ng/mL. In the final multivariable-adjusted model, serum E-Screen activity was positively associated with serum estradiol, estrone, IGFBP-3, and testosterone levels (p<0.05), as well as body mass index (p=0.03). Serum E-Screen activity was lower among women with higher SHBG (p<0.0001) and progesterone levels (p=0.03). Conclusion Serum E-Screen activity varies according to levels of endogenous estrogens and other serum molecules. Obesity appears to confer additional serum mitogenicity beyond its impact on the measured hormones and growth factors. Impact By capturing mitogenicity due to a variety of patient and serum factors, the E-Screen may provide advantages for use as a biomarker in breast cancer studies. PMID:23588007
Higher serum 25-hydroxyvitamin D concentrations are related to a reduced risk of depression.
Jääskeläinen, Tuija; Knekt, Paul; Suvisaari, Jaana; Männistö, Satu; Partonen, Timo; Sääksjärvi, Katri; Kaartinen, Niina E; Kanerva, Noora; Lindfors, Olavi
2015-05-14
Vitamin D has been suggested to protect against depression, but epidemiological evidence is scarce. The present study investigated the relationship of serum 25-hydroxyvitamin D (25(OH)D) with the prevalence of depressive and anxiety disorders. The study population consisted of a representative sample of Finnish men and women aged 30-79 years from the Health 2000 Survey. The sample included 5371 individuals, of which 354 were diagnosed with depressive disorder and 222 with anxiety disorder. Serum 25(OH)D concentration was determined from frozen samples. In a cross-sectional study, a total of four indicators of depression and one indicator of anxiety were used as dependent variables. Serum 25(OH)D was the risk factor of interest, and logistic models used further included sociodemographic and lifestyle variables as well as indicators of metabolic health as confounding and/or effect-modifying factors. The population attributable fraction (PAF) was estimated. Individuals with higher serum 25(OH)D concentrations showed a reduced risk of depression. The relative odds between the highest and lowest quartiles was 0.65 (95% CI 0.46, 0.93; P for trend = 0.006) after adjustment for sociodemographic, lifestyle and metabolic factors. Higher serum 25(OH)D concentrations were associated with a lower prevalence of depressive disorder especially among men, younger, divorced and those who had an unhealthy lifestyle or suffered from the metabolic syndrome. The PAF was estimated to be 19% for depression when serum 25(OH)D concentration was at least 50 nmol/l. These results support the hypothesis that higher serum 25(OH)D concentrations protect against depression even after adjustment for a large number of sociodemographic, lifestyle and metabolic factors. Large-scale prospective studies are needed to confirm this finding.
Pedroza, Kelly C M C; de Matos, Sócrates B; de Moura, Daniel L; Oliveira, Mônica B B; Araújo, Marco A S; Nascimento, Roberto J M; Lima, Fernanda W M
2013-10-01
Galactomannan (GM) was recently included in consensus guidelines as an indirect mycological criterion for the diagnosis of invasive aspergillosis. Currently, there is an enzyme immunoassay available to detect GM in biological samples, the Platelia™ Aspergillus EIA. In this study, the reproducibility of positive results obtained using this assay was evaluated using serum samples from neutropenic patients. A trend toward lower values was observed, and 55 %(27/49) of positive results were negative after retesting. A low reproducibility of positive results for the detection of GM in serum was observed.
Serum levels of perfluoroalkyl compounds in human maternal and umbilical cord blood samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monroy, Rocio; Morrison, Katherine; Teo, Koon
2008-09-15
Perfluoroalkyl compounds (PFCs) are end-stage metabolic products from industrial flourochemicals used in the manufacture of plastics, textiles, and electronics that are widely distributed in the environment. The objective of the present study was to quantify exposure to perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), perfluorodecanoic acid (PFDeA), perfluorohexane sulfonate (PFHxS), perfluoroheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA) in serum samples collected from pregnant women and the umbilical cord at delivery. Pregnant women (n=101) presenting for second trimester ultrasound were recruited and PFC residue levels were quantified in maternal serum at 24-28 weeks of pregnancy, at delivery, and in umbilical cord blood (UCB;more » n=105) by liquid chromatography-mass spectrometry. Paired t-test and multiple regression analysis were performed to determine the relationship between the concentrations of each analyte at different sample collection time points. PFOA and PFOS were detectable in all serum samples analyzed including the UCB. PFOS serum levels (mean{+-}S.D.) were significantly higher (p<0.001) in second trimester maternal serum (18.1{+-}10.9 ng/mL) than maternal serum levels at delivery (16.2{+-}10.4 ng/mL), which were higher than the levels found in UCB (7.3{+-}5.8 ng/mL; p<0.001). PFHxS was quantifiable in 46/101 (45.5%) maternal and 21/105 (20%) UCB samples with a mean concentration of 4.05{+-}12.3 and 5.05{+-}12.9 ng/mL, respectively. There was no association between serum PFCs at any time point studied and birth weight. Taken together our data demonstrate that although there is widespread exposure to PFCs during development, these exposures do not affect birth weight.« less
Loeffler, David A; Klaver, Andrea C
2017-11-01
Specific antibody concentrations are frequently measured in serum (and plasma and intravenous immunoglobulin) samples by enzyme-linked immunosorbent assay (ELISA). The standard negative control involves incubation of buffer alone on antigen-coated wells. The immunoreactivity that develops in antigen-coated wells in which diluted serum has been incubated is assumed to represent specific antibody binding. This approach can result in marked overestimation of specific antibody levels, because serum contains specific polyvalent antibodies which bind, primarily with low affinity, to multiple antigens (including those on ELISA plates) despite the use of blocking agents. Non-denaturing purification of serum IgG, followed by assessment of the antigen binding or antigen-binding affinity of this purified IgG, can reduce but not eliminate the problem of polyvalent antibody binding in indirect ELISAs. Alternatively, polyvalent antibody binding can be estimated by incubating a diluted serum sample on wells coated with an irrelevant protein (such as bovine serum albumin or a scrambled peptide sequence) or buffer alone, then subtracting this reactivity from the sample's binding to wells coated with the antigen of interest. Polyvalent binding of immunoglobulins must be accounted for in order to obtain accurate ELISA measurements of serum, plasma, or intravenous immunoglobulin antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
Natsios, Athanasios; Vezakis, Antonios; Kaparos, Georgios; Fragulidis, Georgios; Karakostas, Nikolaos; Kouskouni, Evangelia; Logothetis, Emmanouil; Polydorou, Andreas
2015-01-01
Serum and bile tumor markers are under intense scrutiny for the diagnosis of malignant disease. The purpose of our study was to report the usefulness of serum and bile tumor markers for the discrimination between benign and malignant pancreatobiliary diseases. Between March 2010 and May 2013, 95 patients with obstructive jaundice or history of biliary obstruction, were included in the study. During ERCP, bile samples were obtained for measurement of tumor markers CEA, CA19- 9, CA125, CA72-4 and CA242. Serum samples were taken before ERCP for the same measurements. The patients were divided into two groups: patients with malignant disease and patients with benign disease. Serum tumor marker levels were significantly higher in patients with malignant disease. Serum CA242 and CA19-9 exhibited the highest diagnostic accuracy (76.8% and 73.7%, respectively). CA125 and CA72-4 levels in bile samples were significantly higher in patients with malignant disease. Bile CA125, CEA and CA72-4 achieved the best diagnostic accuracy (69, 65 and 65), respectively). The combined detection of CA19-9, CA242 in serum and CA125, CA72-4 in bile along with total bilirubin levels, showed the best diagnostic accuracy (81%). Serum and bile tumor markers, when studied alone, lack the diagnostic yield to discriminate benign from malignant pancreatobiliary diseases. In cases of diagnostic dilemmas the combination of serum and bile markers might be helpful.
NASA Astrophysics Data System (ADS)
Treado, Patrick J.; Stewart, Shona D.; Smith, Aaron; Kirschner, Heather; Post, Christopher; Overholt, Bergein F.
2016-03-01
Colorectal cancer (CRC) is the third most common cancer in men and women in the United States. Raman Molecular Imaging (RMI) is an effective technique to evaluate human tissue, cells and bodily fluids, including blood serum for disease diagnosis. ChemImage Corporation, in collaboration with clinicians, has been engaged in development of an in vitro diagnostic Raman assay focused on CRC detection. The Raman Assay for Colorectal Cancer (RACC) exploits the high specificity of Raman imaging to distinguish diseased from normal dried blood serum droplets without additional reagents. Pilot Study results from testing of hundreds of biobank patient samples have demonstrated that RACC detects CRC with high sensitivity and specificity. However, expanded clinical trials, which are ongoing, are revealing a host of important preanalytical considerations associated with sample collection, sample storage and stability, sample shipping, sample preparation and sample interferents, which impact detection performance. Results from recent clinical studies will be presented.
Butler, Emily K; Gersch, Jeffrey; McNamara, Anne; Luk, Ka-Cheung; Holzmayer, Vera; de Medina, Maria; Schiff, Eugene; Kuhns, Mary; Cloherty, Gavin A
2018-05-07
Treatment of chronic hepatitis B (CHB) patients with nucleos(t)ide analogues (NA) suppresses HBV DNA synthesis but does not affect synthesis of HBV pregenomic RNA (pgRNA). HBV pgRNA is detectable in the serum during NA treatment and has been proposed as a marker of HBV covalently closed circular DNA (cccDNA) activity within the infected hepatocyte. We developed an automated assay for the quantification of serum HBV pgRNA using a dual-target qRT-PCR approach on the Abbott m2000sp/rt system. We demonstrate accurate detection and quantification of serum HBV RNA. HBV DNA was quantified using the Abbott RealTime HBV viral load assay. We further compared serum nucleic acid levels and kinetics in HBV-positive populations. Samples included: on-therapy CHB samples (N=16), samples (N=89) from 10 treatment naïve CHB subjects receiving 12-weeks of NA treatment with 8-week follow-up, HBsAg-positive blood donor samples (N=102), and 3 seroconversion series from plasmapheresis donors (N=79 samples). During NA treatment of CHB subjects, we observed low correlation of HBV DNA to pgRNA levels; pgRNA concentration was generally higher than HBV DNA concentrations. In contrast, when NA treatment was absent we observed serum pgRNA at concentrations that correlated to HBV DNA and were approximately 2 log lower than HBV DNA. Importantly, we observe this trend in untreated subject samples from both chronic infections and throughout seroconversion during acute infection. Results demonstrate that the presence of pgRNA in serum is part of the HBV lifecycle; constant relative detection of pgRNA and HBV DNA in the serum is suggestive of a linked mechanism for egress for HBV DNA or pgRNA containing virions. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-07
To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-01
AIM: To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). METHODS: Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn’s disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student’s t test (α = 0.05). RESULTS: The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. CONCLUSION: NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission. PMID:24415869
Sub-tesla-field magnetization of vibrated magnetic nanoreagents for screening tumor markers
NASA Astrophysics Data System (ADS)
Chieh, Jen-Jie; Huang, Kai-Wen; Shi, Jin-Cheng
2015-02-01
Magnetic nanoreagents (MNRs), consisting of liquid solutions and magnetic nanoparticles (MNPs) coated with bioprobes, have been widely used in biomedical disciplines. For in vitro tests of serum biomarkers, numerous MNR-based magnetic immunoassay methods or schemes have been developed; however, their applications are limited. In this study, a vibrating sample magnetometer (VSM) was used for screening tumor biomarkers based on the same MNRs as those used in other immunoassay methods. The examination mechanism is that examined tumor biomarkers are typically conjugated to the bioprobes coated on MNPs to form magnetic clusters. Consequently, the sub-Tesla-field magnetization (Msub-T) of MNRs, including magnetic clusters, exceeds that of MNRs containing only separate MNPs. For human serum samples, proteins other than the targeted biomarkers induce the formation of magnetic clusters with increased Msub-T because of weak nonspecific binding. In this study, this interference problem was suppressed by the vibration condition in the VSM and analysis. Based on a referenced Msub-T,0 value defined by the average Msub-T value of a normal person's serum samples, including general proteins and few tumor biomarkers, the difference ΔMsub-T between the measured Msub-T and the reference Msub-T,0 determined the expression of only target tumor biomarkers in the tested serum samples. By using common MNRs with an alpha-fetoprotein-antibody coating, this study demonstrated that a current VSM can perform clinical screening of hepatocellular carcinoma.
Feng, Zufei; Xu, Yuehong; Wei, Shuguang; Zhang, Bao; Guan, Fanglin; Li, Shengbin
2015-01-01
A magnetic carbon nanomaterial for Fe3O4-modified hydroxylated multi-walled carbon nanotubes (Fe3O4-MWCNTs-OH) was prepared by the aggregating effect of Fe3O4 nanoparticles on MWCNTs-OH, and this material was combined with high-performance liquid chromatography (HPLC)/photodiode array detector (PAD) to determine strychnine in human serum samples. Some important parameters that could influence the extraction efficiency of strychnine were optimized, including the extraction time, amounts of Fe3O4-MWCNTs-OH, pH of sample solution, desorption solvent and desorption time. Under optimal conditions, the recoveries of spiked serum samples were between 98.3 and 102.7%, and the relative standard deviations (RSDs) ranged from 0.9 to 5.3%. The correlation coefficient was 0.9997. The LODs and LOQs of strychnine were 6.2 and 20.5 ng mL(-1), at signal-to-noise ratios of 3 and 10, respectively. These experimental results showed that the proposed method is feasible for the analysis of strychnine in serum samples.
Nipah Virus in Lyle's Flying Foxes, Cambodia
Counor, Dorian; Ong, Sivuth; Faure, Caroline; Seng, Vansay; Molia, Sophie; Walston, Joe; Georges-Courbot, Marie Claude; Deubel, Vincent; Sarthou, Jean-Louis
2005-01-01
We conducted a survey in Cambodia in 2000 on henipavirus infection among several bat species, including flying foxes, and persons exposed to these animals. Among 1,072 bat serum samples tested by enzyme-linked immunosorbent assay, antibodies reactive to Nipah virus (NiV) antigen were detected only in Pteropus lylei species; Cynopterus sphinx, Hipposideros larvatus, Scotophilus kuhlii, Chaerephon plicata, Taphozous melanopogon, and T. theobaldi species were negative. Seroneutralization applied on a subset of 156 serum samples confirmed these results. None of the 8 human serum samples was NiV seropositive with the seroneutralization test. One virus isolate exhibiting cytopathic effect with syncytia was obtained from 769 urine samples collected at roosts of P. lylei specimens. Partial molecular characterization of this isolate demonstrated that it was closely related to NiV. These results strengthen the hypothesis that flying foxes could be the natural host of NiV. Surveillance of human cases should be implemented. PMID:16022778
Thelin, Eric Peter; Zeiler, Frederick Adam; Ercole, Ari; Mondello, Stefania; Büki, András; Bellander, Bo-Michael; Helmy, Adel; Menon, David K; Nelson, David W
2017-01-01
The proteins S100B, neuron-specific enolase (NSE), glial fibrillary acidic protein (GFAP), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), and neurofilament light (NF-L) have been serially sampled in serum of patients suffering from traumatic brain injury (TBI) in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term "effective half-life" ( t 1/2 ) in order to describe the "fall" rate in serum. Through searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations. Following screening (10,389 papers), n = 122 papers were included. The proteins S100B ( n = 66) and NSE ( n = 27) were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t 1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1-2 h) though possibly of non-cerebral origin. In contrast, the t 1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP ( n = 18) appears to have t 1/2 of about 24-48 h in severe TBI. The protein UCH-L1 ( n = 9) presents a t 1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L ( n = 2) only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use. Serial sampling of brain-specific proteins in serum reveals different temporal trajectories that should be acknowledged. Proteins with shorter serum availability, like S100B, may be superior to proteins such as NF-L in detection of secondary harmful events when monitoring patients with TBI.
Berger, Sanne Schou; Lauritsen, Klara Tølbøll; Boas, Ulrik; Lind, Peter; Andresen, Lars Ole
2017-11-01
We developed and made a preliminary validation of a bead-based multiplexed immunoassay for simultaneous detection of porcine serum antibodies to Actinobacillus pleuropneumoniae serovars 1, 2, 6, 7, and 12. Magnetic fluorescent beads were coupled with A. pleuropneumoniae antigens and tested with a panel of serum samples from experimentally infected pigs and with serum samples from uninfected and naturally infected pigs. The multiplex assay was compared to in-house ELISAs and complement fixation (CF) tests, which have been used for decades as tools for herd classification in the Danish Specific Pathogen Free system. Assay specificities and sensitivities as well as the corresponding cutoff values were determined using receiver operating characteristic (ROC) curve analysis, and the A. pleuropneumoniae multiplex assay showed good correlation with the in-house ELISAs and CF tests with areas under ROC curves ≥ 0.988. Benefits of multiplexed assays compared to ELISAs and CF tests include reduced serum sample volumes needed for analysis, less labor, and shorter assay time.
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Wei-Jun; Leach, Robin J.; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srivastava, Sudhir; Rodland, Karin D.; Camp, David G.
2012-01-01
Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. PMID:22846433
Protein microarray analysis reveals BAFF-binding autoantibodies in systemic lupus erythematosus
Price, Jordan V.; Haddon, David J.; Kemmer, Dodge; Delepine, Guillaume; Mandelbaum, Gil; Jarrell, Justin A.; Gupta, Rohit; Balboni, Imelda; Chakravarty, Eliza F.; Sokolove, Jeremy; Shum, Anthony K.; Anderson, Mark S.; Cheng, Mickie H.; Robinson, William H.; Browne, Sarah K.; Holland, Steven M.; Baechler, Emily C.; Utz, Paul J.
2013-01-01
Autoantibodies against cytokines, chemokines, and growth factors inhibit normal immunity and are implicated in inflammatory autoimmune disease and diseases of immune deficiency. In an effort to evaluate serum from autoimmune and immunodeficient patients for Abs against cytokines, chemokines, and growth factors in a high-throughput and unbiased manner, we constructed a multiplex protein microarray for detection of serum factor–binding Abs and used the microarray to detect autoantibody targets in SLE. We designed a nitrocellulose-surface microarray containing human cytokines, chemokines, and other circulating proteins and demonstrated that the array permitted specific detection of serum factor–binding probes. We used the arrays to detect previously described autoantibodies against cytokines in samples from individuals with autoimmune polyendocrine syndrome type 1 and chronic mycobacterial infection. Serum profiling from individuals with SLE revealed that among several targets, elevated IgG autoantibody reactivity to B cell–activating factor (BAFF) was associated with SLE compared with control samples. BAFF reactivity correlated with the severity of disease-associated features, including IFN-α–driven SLE pathology. Our results showed that serum factor protein microarrays facilitate detection of autoantibody reactivity to serum factors in human samples and that BAFF-reactive autoantibodies may be associated with an elevated inflammatory disease state within the spectrum of SLE. PMID:24270423
Fiore, D; Auger, F A; Drusano, G L; Dandu, V R; Lesko, L J
1984-01-01
A rapid, sensitive, and specific method of analysis for mezlocillin in serum and urine by high-pressure liquid chromatography is described. A solid-phase extraction column was used to remove interfering substances from samples before chromatography. Quantitation included the use of an internal standard, nafcillin. Mezlocillin was chromatographed with a phosphate buffer-acetonitrile (73:27) mobile phase and a C-18 reverse-phase column and detected at a wavelength of 220 nm. The assay had a sensitivity of 1.6 micrograms/ml and a linearity of up to 600 micrograms/ml and 16 mg/ml in serum and urine, respectively, with only 0.1 ml of sample. The interday and intraday coefficients of variation for replicate analyses of spiked serum and urine specimens were less than 6.5%. PMID:6517560
Rezende, Vinícius Marcondes; Rivellis, Ariane Julio; Gomes, Melissa Medrano; Dörr, Felipe Augusto; Novaes, Mafalda Megumi Yoshinaga; Nardinelli, Luciana; Costa, Ariel Lais de Lima; Chamone, Dalton de Alencar Fisher; Bendit, Israel
2013-01-01
Objective The goal of this study was to monitor imatinib mesylate therapeutically in the Tumor Biology Laboratory, Department of Hematology and Hemotherapy, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo (USP). A simple and sensitive method to quantify imatinib and its metabolite (CGP74588) in human serum was developed and fully validated in order to monitor treatment compliance. Methods The method used to quantify these compounds in serum included protein precipitation extraction followed by instrumental analysis using high performance liquid chromatography coupled with mass spectrometry. The method was validated for several parameters, including selectivity, precision, accuracy, recovery and linearity. Results The parameters evaluated during the validation stage exhibited satisfactory results based on the Food and Drug Administration and the Brazilian Health Surveillance Agency (ANVISA) guidelines for validating bioanalytical methods. These parameters also showed a linear correlation greater than 0.99 for the concentration range between 0.500 µg/mL and 10.0 µg/mL and a total analysis time of 13 minutes per sample. This study includes results (imatinib serum concentrations) for 308 samples from patients being treated with imatinib mesylate. Conclusion The method developed in this study was successfully validated and is being efficiently used to measure imatinib concentrations in samples from chronic myeloid leukemia patients to check treatment compliance. The imatinib serum levels of patients achieving a major molecular response were significantly higher than those of patients who did not achieve this result. These results are thus consistent with published reports concerning other populations. PMID:23741187
Fast detection of Piscirickettsia salmonis in Salmo salar serum through MALDI-TOF-MS profiling.
Olate, Verónica R; Nachtigall, Fabiane M; Santos, Leonardo S; Soto, Alex; Araya, Macarena; Oyanedel, Sandra; Díaz, Verónica; Marchant, Vanessa; Rios-Momberg, Mauricio
2016-03-01
Piscirickettsia salmonis is a pathogenic bacteria known as the aetiological agent of the salmonid rickettsial syndrome and causes a high mortality in farmed salmonid fishes. Detection of P. salmonis in farmed fishes is based mainly on molecular biology and immunohistochemistry techniques. These techniques are in most of the cases expensive and time consuming. In the search of new alternatives to detect the presence of P. salmonis in salmonid fishes, this work proposed the use of MALDI-TOF-MS to compare serum protein profiles from Salmo salar fish, including experimentally infected and non-infected fishes using principal component analysis (PCA). Samples were obtained from a controlled bioassay where S. salar was challenged with P. salmonis in a cohabitation model and classified according to the presence or absence of the bacteria by real time PCR analysis. MALDI spectra of the fish serum samples showed differences in its serum protein composition. These differences were corroborated with PCA analysis. The results demonstrated that the use of both MALDI-TOF-MS and PCA represents a useful tool to discriminate the fish status through the analysis of salmonid serum samples. Copyright © 2016 John Wiley & Sons, Ltd.
Barrachina, Laura; Remacha, Ana Rosa; Soler, Lourdes; García, Natalia; Romero, Antonio; Vázquez, Francisco José; Vitoria, Arantza; Álava, María Ángeles; Lamprave, Fermín; Rodellar, Clementina
2016-12-01
Acute phase proteins are useful inflammatory markers in horses. Haptoglobin (Hp) serum level is increased in horses undergoing different inflammatory processes, including arthritis. However, Hp concentration has not been assessed in inflammatory synovial fluid (SF). The aim of the present study was to investigate the Hp response in serum and SF in horses undergoing experimentally induced arthritis. For this purpose, serum and SF samples were collected from 12 animals before amphotericin B-induced arthritis was created (T0, healthy) and 15days after the lesion induction (T1, joint inflammation) and Hp was determined by single radial immunodiffusion. The Hp increase between T0 and T1 was significant in both serum and SF, and serum Hp concentration at T0 was significantly higher than in SF, but significant differences were not found at T1, indicating a higher Hp increase in SF. A significant positive correlation for Hp concentration between serum and SF samples was found. These results highlight the potential usefulness of Hp as inflammatory marker in horses, showing for the first time the increase of Hp in SF from joint inflammation in the horse. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Whiitson, Peggy A. (Inventor); Clift, Vaughan L. (Inventor)
1999-01-01
The present invention provides a method and apparatus for separating a blood sample having a volume of up to about 20 milliliters into cellular and acellular fractions. The apparatus includes a housing divided by a fibrous filter into a blood sample collection chamber having a volume of at least about 1 milliliter and a serum sample collection chamber. The fibrous filter has a pore size of less than about 3 microns, and is coated with a mixture including between about 1-40 wt/vol % mannitol and between about 0.1-15 wt/vol % of plasma fraction protein (or an animal or vegetable equivalent thereof). The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber.
SELDI-TOF-MS proteomic profiling of serum, urine, and amniotic fluid in neural tube defects.
Liu, Zhenjiang; Yuan, Zhengwei; Zhao, Qun
2014-01-01
Neural tube defects (NTDs) are common birth defects, whose specific biomarkers are needed. The purpose of this pilot study is to determine whether protein profiling in NTD-mothers differ from normal controls using SELDI-TOF-MS. ProteinChip Biomarker System was used to evaluate 82 maternal serum samples, 78 urine samples and 76 amniotic fluid samples. The validity of classification tree was then challenged with a blind test set including another 20 NTD-mothers and 18 controls in serum samples, and another 19 NTD-mothers and 17 controls in urine samples, and another 20 NTD-mothers and 17 controls in amniotic fluid samples. Eight proteins detected in serum samples were up-regulated and four proteins were down-regulated in the NTD group. Four proteins detected in urine samples were up-regulated and one protein was down-regulated in the NTD group. Six proteins detected in amniotic fluid samples were up-regulated and one protein was down-regulated in the NTD group. The classification tree for serum samples separated NTDs from healthy individuals, achieving a sensitivity of 91% and a specificity of 97% in the training set, and achieving a sensitivity of 90% and a specificity of 97% and a positive predictive value of 95% in the test set. The classification tree for urine samples separated NTDs from controls, achieving a sensitivity of 95% and a specificity of 94% in the training set, and achieving a sensitivity of 89% and a specificity of 82% and a positive predictive value of 85% in the test set. The classification tree for amniotic fluid samples separated NTDs from controls, achieving a sensitivity of 93% and a specificity of 89% in the training set, and achieving a sensitivity of 90% and a specificity of 88% and a positive predictive value of 90% in the test set. These suggest that SELDI-TOF-MS is an additional method for NTDs pregnancies detection.
Metabolic Footprinting of Fermented Milk Consumption in Serum of Healthy Men
Pimentel, Grégory; Burton, Kathryn J; von Ah, Ueli; Bütikofer, Ueli; Pralong, François P; Vionnet, Nathalie; Portmann, Reto; Vergères, Guy
2018-01-01
Abstract Background Fermentation is a widely used method of natural food preservation that has consequences on the nutritional value of the transformed food. Fermented dairy products are increasingly investigated in view of their ability to exert health benefits beyond their nutritional qualities. Objective To explore the mechanisms underpinning the health benefits of fermented dairy intake, the present study followed the effects of milk fermentation, from changes in the product metabolome to consequences on the human serum metabolome after its ingestion. Methods A randomized crossover study design was conducted in 14 healthy men [mean age: 24.6 y; mean body mass index (in kg/m2): 21.8]. At the beginning of each test phase, serum samples were taken 6 h postprandially after the ingestion of 800 g of a nonfermented milk or a probiotic yogurt. During the 2-wk test phases, subjects consumed 400 g of the assigned test product daily (200 g, 2 times/d). Serum samples were taken from fasting participants at the end of each test phase. The serum metabolome was assessed through the use of LC-MS–based untargeted metabolomics. Results Postprandial serum metabolomes after milk or yogurt intake could be differentiated [orthogonal projections to latent structures discriminant analysis (OPLS-DA) Q2 = 0.74]. Yogurt intake was characterized by higher concentrations of 7 free amino acids (including proline, P = 0.03), reduced concentrations of 5 bile acids (including glycocholic acid, P = 0.04), and modulation of 4 indole derivative compounds (including indole lactic acid, P = 0.01). Fasting serum samples after 2 wk of daily intake of milk or yogurt could also be differentiated based on their metabolic profiles (OPLS-DA Q2 = 0.56) and were discussed in light of the postprandial results. Conclusion Metabolic pathways related to amino acids, indole derivatives, and bile acids were modulated in healthy men by the intake of yogurt. Further investigation to explore novel health effects of fermented dairy products is warranted.This trial was registered at clinicaltrials.gov as NCT02230345. PMID:29788433
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kronewitter, Scott R.; Marginean, Ioan; Cox, Jonathan T.
The N-glycan diversity of human serum glycoproteins, i.e. the human blood serum N-glycome, is complex due to the range of glycan structures potentially synthesizable by human glycosylation enzymes. The reported glycome, however, is limited by methods of sample preparation, available analytical platforms, e.g., based upon electrospray ionization-mass spectrometry (ESI-MS), and software tools for data analysis. In this report, several improvements have been implemented in sample preparation and analysis to extend ESI-MS glycan characterization and to provide an improved view of glycan diversity. Sample preparation improvements include acidified, microwave-accelerated, PNGase F N-glycan release, and sodium borohydride reduction were optimized to improvemore » quantitative yields and conserve the number of glycoforms detected. Two-stage desalting (during solid phase extraction and on the analytical column) increased the sensitivity by reducing analyte signal division between multiple reducing-end-forms or cation adducts. On-line separations were improved by using extended length graphitized carbon columns and adding TFA as an acid modifier to a formic acid/reversed phase gradient which provides additional resolving power and significantly improved desorption of both large and heavily sialylated glycans. To improve MS sensitivity and provide gentler ionization conditions at the source-MS interface, subambient pressure ionization with nanoelectrospray (SPIN) has been utilized. When method improvements are combined together with the Glycomics Quintavariate Informed Quantification (GlyQ-IQ) recently described1 these technologies demonstrate the ability to significantly extend glycan detection sensitivity and provide expanded glycan coverage. We demonstrate application of these advances in the context of the human serum glycome, and for which our initial observations include detection of a new class of heavily sialylated N-glycans, including polysialylated N-glycans.« less
Comparison of lacosamide concentrations in cerebrospinal fluid and serum in patients with epilepsy.
May, Theodor W; Brandt, Christian; Helmer, Renate; Bien, Christian G; Cawello, Willi
2015-07-01
This study was carried out to estimate the exposure of the central nervous system (CNS) to the antiepileptic drug (AED) lacosamide, under steady state conditions, in patients with epilepsy who take oral lacosamide alongside up to three other AEDs. Twenty-seven serum and cerebral spinal fluid (CSF) samples were collected from 21 patients receiving lacosamide for the treatment of epilepsy (50-600 mg/day over two or three doses). This included 23 time-matched pairs of serum and CSF samples from 19 patients. The concentration of lacosamide in each sample was determined using high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). Linear regression was used to characterize the relationship between the CSF-to-serum ratio of lacosamide concentration and the time since dosing, the daily lacosamide dose, or the daily dose normalized by volume of distribution (Vd , approximated to total body water), and between the drug concentrations in each compartment (CSF vs. serum). Concentrations of lacosamide in CSF (mean ± standard deviation [SD] 7.37 ± 3.73 μg/ml, range 1.24-14.95, n = 27) and serum (mean ± SD 8.16 ± 3.82 μg/ml, range 2.29-15.45, n = 27) samples showed a good correlation over the dose range investigated. The mean CSF-to-serum ratio of lacosamide concentrations was 0.897 ± 0.193 (range 0.492-1.254, n = 23 time-matched pairs) and was independent of lacosamide dose. Drug concentrations in the CSF are often used to indicate those in the brain interstitial fluid. In patients with epilepsy who follow a stable oral AED dosing regimen, lacosamide concentration in CSF is approximately 85% of that found in serum, suggesting that serum may be a valuable indicator of lacosamide concentration in the CNS. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.
Kim, Jun-Tae; Son, Min-Hui; Lee, Duk-Hee; Seong, Won Joon; Han, Seunghee; Chang, Yoon-Seok
2015-06-16
Heavy metals and persistent organic pollutants (POPs), including Pb, Cd, T-Hg, MeHg, PCDD/Fs, PCBs, PBDEs, PCNs, and PBDD/Fs, were analyzed in 20 paired samples of cord blood, maternal blood, maternal urine, and placenta. The samples were collected from pregnant mothers and neonates from South Korea in 2010. The distribution of heavy metals among the samples varied with their physicochemical characteristics. The concentrations of Pb and Hg in the maternal and the cord blood samples were significantly correlated each other, implying efficient transplacental transport (TPT). Cd and Hg were accumulated in the placenta, forming protein conjugates, and T-Hg was higher in the cord blood samples than the maternal blood samples due to the binding affinity of Hg with fetal proteins. POPs generally showed the highest concentrations in the maternal serum samples, and the POPs levels in the cord serum and the placenta samples were dependent on the degree of halogenation. The TPT of POPs was seemingly related to lipoprotein transportation. Some PBDE congeners, however, showed their highest concentrations in the cord serum samples, suggesting an additional TPT mechanism. This is the first study to detect PCNs and PBDD/Fs in the cord serum samples, showing that the PCN levels were comparable to other POPs. According to the principal component analysis (PCA) results of the contaminant levels, POPs and heavy metals showed significantly different characteristics, whereas PBDEs had an intermediate attribute. Despite the limited number of participants, the comprehensive analysis of trace contaminants in the paired sample sets enabled us to infer the distribution and TPT mechanism of various contaminants.
Wang, Yajie; Yu, Jinsheng; Ren, Yuan; Liu, Li; Li, Haowen; Guo, Anchen; Shi, Congning; Fang, Fang; Juehne, Twyla; Yao, Jianer; Yang, Enhuan; Zhou, Xuelei; Kang, Xixiong
2013-11-15
A variety of immunoassays including multiplex suspension bead array have been developed for tumor marker detections; however, these assays could be compromised in their sensitivity and specificity by well-known heterophile antibody interference and hook effect. Using Luminex® multiplex suspension bead arrays, we modified protocols with two newly-developed solutions that can identify heterophile antibody interference and AFP hook effect. Effectiveness of the two solutions was assessed in serum samples from patients. Concentrations of 9 tumor markers in heterophile antibody positive samples assayed with Solution A, containing murine monoclonal antibodies and mouse serum, were significantly reduced when compared with those false high signals assayed without Solution A (all p<0.01). With incorporation of Solution H (fluorescent beads linked with AFP antigen), a new strategy for identification of AFP hook effect was established, and with this strategy AFP hook effect was identified effectively in serum samples with very high levels of AFP. Two proprietary solutions improve the identification of heterophile antibody interference and AFP hook effect. With these solutions, multiplex suspension bead arrays provide more reliable testing results in tumor marker detection where complex clinical serum samples are used. © 2013.
High serum 25-hydroxyvitamin D levels are associated with pediatric sepsis.
Aydemir, Gokhan; Cekmez, Ferhat; Kalkan, Gokhan; Fidanci, M Kursat; Kaya, Guven; Karaoglu, Abdulbaki; Meral, Cihan; Arzıman, İbrahim; Karademir, Ferhan; Ayar, Ganime; Gunduz, Ramiz Coskun; Suleymanoglu, Selami
2014-12-01
Despite major advances in intensive care, sepsis continues to be a major cause of morbidity and mortality. Vitamin D is involved in various physiologic functions, including cellular responses during infection and inflammation. The aim of this study was to evaluate diagnostic value of 25-hydroxyvitamin D in childhood sepsis because it can be fatal if diagnosis delayed. The study included 40 children with sepsis and 20 children without sepsis (control group). We included only the patients with high probable sepsis, judged by clinical and laboratory findings, including positive blood culture. Blood samples were collected from patients with sepsis before treatment (pre-treatment group) and 48-72 hours later (post-treatment group). Treatment varied from ampicillin-sulbactam to cephalosporin. Blood samples were collected from control group once on admission. Serum 25-hydroxyvitamin D levels were significantly higher in sepsis (pre-treatment group) than control group (74 ± 8 ng/ml vs. 28 ± 12 ng/ml, p = 0.01) and the serum 25-hydroxyvitamin D levels were decreased to 44 ± 5 ng/ml (p = 0.01) after treatment. Moreover, we found significant positive correlation between 25-hydroxyvitamin D and each of well-know sepsis markers, C-reactive protein, tumor necrosis factor-α and interleukin-6. A cut-off point of 20 ng/mL for serum 25-hydroxyvitamin D showed 84% sensitivity and 76% specificity for sepsis diagnosis. This is the first study evaluating the diagnostic role of vitamin D in pediatric sepsis, thereby suggesting that serum 25-hydroxyvitamin D level can be used as a diagnostic marker for sepsis with high sensitivity and specificity.
Onwuneme, C; Diya, B; Uduma, O; McCarthy, R A; Murphy, N; Kilbane, M T; McKenna, M J; Molloy, E J
2016-08-01
Although the role of vitamin D in the prevention of rickets has long been well established, controversies still exist on the ideal dose of vitamin D supplementation in infants. We assessed serum 25-hydroxyvitamin D (25OHD) status simultaneously in maternal and cord samples and the response to vitamin D3 supplementation in neonates. Serum 25OHD levels were evaluated from maternal, and umbilical cord samples from term normal pregnancies. Repeat 25OHD levels were assessed in neonates with 25OHD below 30 nmol/L following vitamin D3 200 IU daily after 6 weeks. Blood samples were taken including 57 cord samples and 16 follow-up neonatal samples. Maternal and cord serum 25OHD were 43 ± 21 and 29 ± 15 nmol/L, respectively. Infants with 25OHD < 30 nmol/L (19.8 ± 4.7 nmol/L) had a significant increase in serum 25OHD (63.3 ± 14.5 nmol/L) following vitamin D3 200 IU daily after 6 weeks. Healthy Irish infants born at term are at high risk of vitamin D deficiency, but vitamin D3 200 IU daily, rapidly corrects poor vitamin D status.
Iwama, Ryosuke; Sato, Tsubasa; Katayama, Masaaki; Shimamura, Shunsuke; Satoh, Hiroshi; Ichijo, Toshihiro; Furuhama, Kazuhisa
2015-08-01
We examined the correlation between the glomerular filtration rate (GFR) estimated from an equation based on the serum iodixanol clearance technique and International Renal Interest Society (IRIS) stages of chronic kidney disease (CKD) in cats. The equation included the injection dose, sampling time, serum concentration and estimated volume of distribution (Vd) of the isotonic, nonionic, contrast medium iodixanol as a test tracer. The percent changes in the median basal GFR values calculated from the equation in CKD cats resembled those of IRIS stages 1-3. These data validate the association between the GFR derived from the simplified equation and IRIS stages based on the serum creatinine concentration in cats with CKD. They describe the GFR ranges determined using single-sample iodixanol clearance for healthy cats and cats with various IRIS stages of CKD.
Yang, Xuezhou; Quan, Xiaozhen; Lan, Yanli; Ye, Jinhai; Wei, Qipeng; Yin, Xiaofang; Fan, Fangfang; Xing, Hui
2017-10-01
To investigate the association between chemerin level in the first trimester of pregnancy and the risk of gestational diabetes mellitus. The blood samples of 212 women at 8-12 weeks of gestation were collected. After screening for gestational diabetes mellitus (GDM), 19 women with GDM and 20 women randomly selected from 144 women with normal glucose tolerance (NGT) were included in the study. Blood samples were collected from these women. Triglycerides, glucose, total cholesterol, and HDL cholesterol, LDL cholesterol, insulin and chemerin were measured. Gestational weight gain and body mass index was assessed. Serum levels of chemerin were significantly elevated during late gestation, and the risk of GDM was positively associated with maternal serum chemerin in the first trimester. Serum chemerin level during the first trimester of pregnancy has the potential to predict risk of GDM.
A comparison of serum and plasma cytokine values using a multiplexed assay in cats.
Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X
2016-12-01
Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
p16 promoter hypermethylation: A useful serum marker for early detection of gastric cancer
Abbaszadegan, Mohammad Reza; Moaven, Omeed; Sima, Hamid Reza; Ghafarzadegan, Kamran; A'rabi, Azadeh; Forghani, Mohammad Naser; Raziee, Hamid Reza; Mashhadinejad, Ali; Jafarzadeh, Mostafa; Esmaili-Shandiz, Ehsan; Dadkhah, Ezzat
2008-01-01
AIM: To determine p16 promoter hypermethylation in gastric tumoral tissue and serum samples, its impact on p16-protein expression, and correlation with clinical and histological features. METHODS: Samples were obtained from 52 histologically confirmed cases of gastric adenocarcinoma. Gastric tissue and serum of 50 age- and sex-matched individuals with normal gastroscopy and biopsy were obtained as control samples. Methylation-specific polymerase chain reaction (MSP) was used to evaluate methylation status of p16 promoter. p16-protein expression was analyzed by immunohistochemical staining on paraffin-embedded sections. RESULTS: Methylation was detected in 44.2% (23/52) of tumoral tissues. 60.9% of them were also methylated in serum, i.e., 26.9% of all patients (14/52). Methylation was not detected in tissue and sera of control samples. p16-protein expression was decreased in 61.5% of cases (32/52), and was significantly associated with promoter hypermethylation (P < 0.001). Methylation was significantly more frequent in higher pathological grades (P < 0.05). Methylation was not associated with other clinicopathological features and environmental factors including H pylori infection and smoking. CONCLUSION: p16 promoter hypermethylation is an important event in gastric carcinogenesis. It is the principle mechanism of p16 gene silencing. It is related to malignant tumor behavior. Detection of DNA methylation in serum may be a biomarker for early detection of gastric cancer. PMID:18395906
Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun
2014-02-01
Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from
Meyer, Golo M; Maurer, Hans H; Meyer, Markus R
2016-01-01
This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.
Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.
Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen
2016-12-01
Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.
Polyfluoroalkyl Chemicals in the Serum and Milk of ...
Polyfluoroalkyl chemicals (PFCs) comprise a group of man-made organic compounds, some of which are persistent contaminants with developmental toxicity shown in laboratory animals. There is a paucity of human perinatal exposure data. The US EPA conducted a pilot study (Methods Advancement in Milk Analysis) including 34 breastfeeding women in North Carolina. Milk and serum samples were collected at 2-7 weeks and 3-4 months postpartum; 9 PFCs were assessed in milk and 7 in serum. Perfluorooctane sulfonic acid (PFOS), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorohexane sulfonic acid (PFHxS) were found in nearly 100% of the serum samples. PFOS and PFOA were found at the highest concentrations. PFCs were below the limit of detection in most milk samples. Serum concentrations of PFOS, PFOA and PFHxS were lower (p<0.01) at the second visit compared to the first visit, and living in North Carolina 10 years or longer was related to elevated PFOS, PFOA and PFNA (p<0.03). These pilot data support the need to further explore perinatal PFC exposures and potentially related health effects, as planned in the upcoming National Children’s Study which provided the framework for this investigation. These data demonstrate very low transfer of perfluorinated chemicals (PFCs) to breast milk, even though PFCs are readily detected in the sera of lactating NC women. Our data correlation statistics suggest that there is an elevation of average serum PFCs i
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Virological Survey in free-ranging wildcats (Felis silvestris) and feral domestic cats in Portugal.
Duarte, A; Fernandes, M; Santos, N; Tavares, L
2012-08-17
To determine the presence of viral pathogens in natural areas a survey was conducted on an opportunistic sample of fifty eight wild (Felis silvestris silvestris) and feral cats (F. s. catus). The biological materials included serum, lung tissue extract and stool. Feline leukemia virus p27 antigen was detected in 13/50 serum/lung tissue extract samples (26%), canine distemper virus antibodies were detected in 2/26 serum/lung tissue extract samples (7.7%), feline coronavirus RNA was present in 6/29 stool samples (20.7%) and feline parvovirus DNA in 2/29 stool samples (6.9%). Canine distemper virus RNA was not detected. Feline immunodeficiency virus and feline coronavirus antibodies were not detected. Evidence of exposure to feline leukemia virus, canine distemper virus, feline coronavirus and feline parvovirus was found in wild and feral cats raising the importance of performing a comprehensive survey to correctly evaluate the potential threat of infectious diseases to endangered species, namely to the wildcat and to the Iberian lynx, which is meant to be reintroduced after 2012 in Portugal. Copyright © 2012 Elsevier B.V. All rights reserved.
Fulton, Robert W.; Hessman, Bill E.; Ridpath, Julia F.; Johnson, Bill J.; Burge, Lurinda J.; Kapil, Sanjay; Braziel, Barbara; Kautz, Kira; Reck, Amy
2009-01-01
Several tests for Bovine viral diarrhea virus (BVDV) were applied to samples collected monthly from December 20, 2005, through November 27, 2006 (day 0 to day 342) from 12 persistently infected (PI) cattle with BVDV subtypes found in US cattle: BVDV-1a, BVDV-1b, and BVDV-2a. The samples included clotted blood for serum, nasal swabs, and fresh and formalin-fixed ear notches. The tests were as follows: titration of infectious virus in serum and nasal swabs; antigen-capture (AC) enzyme-linked immunosorbent assay (ELISA), or ACE, on serum, nasal swabs, and fresh ear notches; gel-based polymerase chain reaction (PCR) testing of serum, nasal swabs, and fresh ear notches; immunohistochemical (IHC) testing of formalin-fixed ear notches; and serologic testing for BVDV antibodies in serum. Of the 12 animals starting the study, 3 died with mucosal disease. The ACE and IHC tests on ear notches had positive results throughout the study, as did the ACE and PCR tests on serum. There was detectable virus in nasal swabs from all the cattle throughout the study except for a few samples that were toxic to cell cultures. The serum had a virus titer ≥ log10 1.60 in all samples from all the cattle except for 3 collections from 1 animal. Although there were several equivocal results, the PCR test most often had positive results. The BVDV antibodies were due to vaccination or exposure to heterologous strains and did not appear to interfere with any BVDV test. These findings illustrate that PI cattle may be identified by several tests, but differentiation of PI cattle from cattle with acute BVDV infection requires additional testing, especially of blood samples and nasal swabs positive on initial testing. Also, calves PI with BVDV are continual shedders of infectious virus, as shown by the infectivity of nasal swabs over the 11-mo study. PMID:19436580
Neuroprotective effect of sevoflurane in general anaesthesia.
Ramos Ramos, Victoria; Mesa Suárez, Pablo; Santotoribio, José Diego; González García, María Ángela; Muñoz Hoyos, Antonio
2017-02-23
The aim of this study was to evaluate the brain damage caused by inhaled sevoflurane, by determining the concentration of serum S100B protein before and after the exposure to this drug as the only anaesthetic agent. Paediatric patients undergoing general anaesthesia for the conduct of a nuclear magnetic resonance were included in the study. A venous blood sample was taken from each patient before (basal sample) and after (post-exposure sample) administering the general anaesthesia. The concentration of serum S100B protein was determined in the basal (S100Bb) and post-exposure sample (S100Bp). A total of 72 patients were included in the study, with a mean patient age of 2 to 13 years (median=6), 28 males and 44 females. S100Bp values (median=66.5ng/L) were significantly lower (P=.0059) than those of S100Bb (median=84.0ng/L). The median of the difference between S100Bp and S100Bb was -11.0ng/L. Inhaled sevoflurane at low doses causes a decrease of serum S100B protein levels, hence, this drug could have a neuroprotective effect in the central nervous system. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Use of dried blood spots for the determination of serum concentrations of tamoxifen and endoxifen.
Jager, N G L; Rosing, H; Schellens, J H M; Beijnen, J H; Linn, S C
2014-07-01
The anti-estrogenic effect of tamoxifen is suggested to be mainly attributable to its metabolite (Z)-endoxifen, and a minimum therapeutic threshold for (Z)-endoxifen in serum has been proposed. The objective of this research was to establish the relationship between dried blood spot (DBS) and serum concentrations of tamoxifen and (Z)-endoxifen to allow the use of DBS sampling, a simple and patient-friendly alternative to venous sampling, in clinical practice. Paired DBS and serum samples were obtained from 50 patients using tamoxifen and analyzed using HPLC-MS/MS. Serum concentrations were calculated from DBS concentrations using the formula calculated serum concentration = DBS concentration/([1-haematocrit (Hct)] + blood cell-to-serum ratio × Hct). The blood cell-to-serum ratio was determined ex vivo by incubating a batch of whole blood spiked with both analytes. The average Hct for female adults was imputed as a fixed value. Calculated and analyzed serum concentrations were compared using weighted Deming regression. Weighted Deming regression analysis comparing 44 matching pairs of DBS and serum samples showed a proportional bias for both analytes. Serum concentrations were calculated using [Tamoxifen] serum, calculated = [Tamoxifen] DBS /0.779 and [(Z)-Endoxifen] serum, calculated = [(Z)-Endoxifen] DBS /0.663. Calculated serum concentrations were within 20 % of analyzed serum concentrations in 84 and 100 % of patient samples for tamoxifen and (Z)-endoxifen, respectively. In conclusion, DBS concentrations of tamoxifen and (Z)-endoxifen were equal to serum concentrations after correction for Hct and blood cell-to-serum ratio. DBS sampling can be used in clinical practice.
Herwig, Ela; Marchetti-Deschmann, Martina; Wenz, Christian; Rüfer, Andreas; Redl, Heinz; Bahrami, Soheyl; Allmaier, Günter
2015-06-01
Sepsis represents a significant cause of mortality in intensive care units. Early diagnosis of sepsis is essential to increase the survival rate of patients. Among others, C-reactive protein (CRP) is commonly used as a sepsis marker. In this work we introduce immune precipitation combined with microchip capillary gel electrophoresis (IP-MCGE) for the detection and quantification of CRP in serum samples. First high-abundance proteins (HSA, IgG) are removed from serum samples using affinity spin cartridges, and then the remaining proteins are labeled with a fluorescence dye and incubated with an anti-CRP antibody, and the antigen/antibody complex is precipitated with protein G-coated magnetic beads. After precipitation the complex is eluted from the beads and loaded onto the MCGE system. CRP could be reliably detected and quantified, with a detection limit of 25 ng/μl in serum samples and 126 pg/μl in matrix-free samples. The overall sensitivity (LOQ = 75 ng/μl, R(2) = 0.9668) of the method is lower than that of some specially developed methods (e.g., immune radiometric assay) but is comparable to those of clinically accepted ELISA methods. The straightforward sample preparation (not prone to mistakes), reduced sample and reagent volumes (including the antibodies), and high throughput (10 samples/3 h) are advantages and therefore IP-MCGE bears potential for point-of-care diagnosis. Copyright © 2015 Elsevier Inc. All rights reserved.
Serological evidence of hepatitis E virus infection in dromedary camels in Ethiopia.
Li, Tian-Cheng; Yoshizaki, Sayaka; Zhou, Xianfeng; Sentsui, Hiroshi; Shirato, Kazuya; Matsuyama, Shutoku; Melaku, Simenew Keskes; Bazartseren, Boldbaatar; Takeda, Naokazu; Wakita, Takaji
2017-08-01
The genome of dromedary camel hepatitis E virus (DcHEV) has been detected in stool and serum samples from dromedary camels, but the sero-epidemiological information of DcHEV infection remains unclear. A total of 246 serum samples collected from dromedary camels (Camelus dromedarius) in Ethiopia, and 40 serum samples from Bactrian camels (Camelus ferus) in Mongolia were examined for the detection of anti-DcHEV IgG antibody by a newly developed enzyme-linked immunosorbent assay (ELISA) by using DcHEV-like particles (DcHEV-LPs) as the antigen. The results revealed that 55 of the 246 (22.4%) dromedary camels were positive for anti-DcHEV IgG, whereas all 40 samples from the Bactrian camels were negative for DcHEV IgG antibody. A total of 98 serum samples from dromedary camels, including 25 anti-DcHEV-IgG positive samples, were used for the detection of DcHEV RNA by reverse transcription-polymerase chain reaction (RT-PCR), however, no positive samples were identified. These results suggested that the DcHEV infection occurred in the dromedary camels in Ethiopia. Further studies are required to determine whether Bactrian camels are susceptible to DcHEV infection. In addition, not only DcHEV-LPs, but also virus-like particles (VLPs) delivered from G1, G3 and G5 HEV are likely applicable for the detection of the anti-DcHEV IgG antibody. Copyright © 2017 Elsevier B.V. All rights reserved.
Detection of hepatitis E virus RNA in saliva for diagnosis of acute infection.
Rivero-Juarez, A; Frias, M; Lopez-Lopez, P; Martinez-Peinado, A; Risalde, M Á; Brieva, T; Machuca, I; Camacho, Á; García-Bocanegra, I; Gomez-Villamandos, J C; Rivero, A
2018-04-16
Diagnosis of acute hepatitis E virus (HEV) infection is established by detection of anti-HEV IgM antibodies by ELISA or by amplification of serum viral RNA. Here, we evaluate the diagnostic value of testing HEV RNA in saliva to identify patients with acute HEV infection. Prospective proof-of-concept study including patients with acute hepatitis. Whole blood and neat saliva samples were obtained from all patients. Saliva samples were processed and analysed for HEV RNA by RT-PCR within 2 hr after collection. A total of 34 patients with acute hepatitis and 12 healthy donors were included in the study. HEV RNA in serum was confirmed by RT-PCR in eight of these patients (23.5%; 95% CI: 12.2%-40.2%). HEV was isolated in the saliva of eight of 34 patients (23.5%; 95% CI: 12.2%-40.2%). All patients with HEV RNA amplified in saliva had detectable HEV RNA in serum. HEV was isolated neither in the saliva of any of the 26 patients without detectable HEV RNA in serum nor in healthy donors. Our study suggests that acute HEV infection could be diagnosed by assessing viral load in saliva. © 2018 Blackwell Verlag GmbH.
Plut, Jan; Toplak, Ivan; Štukelj, Marina
2018-06-01
Over the last few years several porcine epidemic diarrhoea (PED) outbreaks have been discovered in Europe including the first PED case in Slovenia in January 2015. The aim of this study was to determine when PED virus (PEDV) infection started in Slovenia. Serum samples collected between 2012 and 2016 were tested. Three hundred and seventy-five serum samples were collected from 132 Slovenian small, one-site pig farms. Samples were tested for PEDV antibodies utilising three different serological methods: commercially-available indirect ELISA, in-house blocking ELISA test and Immunoperoxidase Monolayer Assay (IPMA) test. One hundred and seventy (45.33%) tested samples were found positive by the commercially-available ELISA test kit, and 10 (5.68%) of these 170 samples found positive were positive by the in-house blocking ELISA. Only these 10 samples were collected from a farm where clinical signs of PED infection had been observed and PEDV was confirmed by RT-PCR methodology; the other 160 samples were collected randomly. Thirty-two samples with the highest S/P value obtained with the commercial ELISA were all negative with IPMA. Reasons for the high variance in the results obtained remain unclear; more research is required to ensure higher sensitivity and specificity in terms of PEDV antibody tests and other PED diagnostic methods.
Serum endocan levels before and after surgery on low-grade gliomas.
Tanriverdi, Taner; Kemerdere, Rahsan; Inal, Berrin B; Yuksel, Odhan; Emre, Humeyra O; Ahmedov, Merdin; Baran, Oguz; Ates, Seda
2017-01-01
Endocan has been shown to be a marker for several cancers and may show degree of malignancy. The aim of this study is to assess serum levels of endocan before and after surgery on low-grade gliomas (LGGs). Endocan was assayed by commercially available enzyme-linked immunosorbent assay (ELISA) kits in a total of 19 patients and 12 controls. Serial serum samples were obtained before and after surgery (1 st day, 1 st week, and 1 st month of surgery). Control samples were collected from cord blood during cesarean section. The results were compared with control brain tissues. Controls showed significantly lower serum endocan levels compared to before and after surgery ( P < 0.05). There is a trend of increase in mean serum levels from before surgery and during the very early period after surgery (during first week); however, in the first month, mean serum levels became lower. Endocan, a vital molecule for angiogenesis, is highly expressed before and after surgery in LGGs, but long-term data is needed. Furthermore, future studies should include high-grade gliomas to discuss whether endocan is associated with recurrence and response to treatment.
Polyfluorinated Compounds in Serum Linked to Indoor Air in Office Environments
Fraser, Alicia J; Webster, Thomas F; Watkins, Deborah J; Nelson, Jessica W; Stapleton, Heather M; Calafat, Antonia M; Kato, Kayoko; Shoeib, Mahiba; Vieira, Verónica M; McClean, Michael D
2011-01-01
We aimed to investigate the role of indoor office air on exposure to polyfluorinated compounds (PFCs) among office workers. Week-long, active air sampling was conducted during the winter of 2009 in 31 offices in Boston, MA. Air samples were analyzed for fluorotelomer alcohols (FTOHs), sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs). Serum was collected from each participant (n=31) and analyzed for twelve PFCs including PFOA and PFOS. In air, FTOHs were present in the highest concentrations, particularly 8:2-FTOH (GM=9,920 pg/m3). FTOHs varied significantly by building with the highest levels observed in a newly constructed building. PFOA in serum was significantly correlated with air levels of 6:2-FTOH (r=0.43), 8:2-FTOH (r=0.60), and 10:2-FTOH (r=0.62). Collectively, FTOHs in air significantly predicted PFOA in serum (p < 0.001) and explained approximately 36% of the variation in serum PFOA concentrations. PFOS in serum was not associated with air levels of FOSAs/FOSEs. In conclusion, FTOH concentrations in office air significantly predict serum PFOA concentrations in office workers. Variation in PFC air concentrations by building is likely due to differences in the number, type, and age of potential sources such as carpeting, furniture and/or paint. PMID:22148395
Polyfluorinated compounds in serum linked to indoor air in office environments.
Fraser, Alicia J; Webster, Thomas F; Watkins, Deborah J; Nelson, Jessica W; Stapleton, Heather M; Calafat, Antonia M; Kato, Kayoko; Shoeib, Mahiba; Vieira, Verónica M; McClean, Michael D
2012-01-17
We aimed to investigate the role of indoor office air on exposure to polyfluorinated compounds (PFCs) among office workers. Week-long, active air sampling was conducted during the winter of 2009 in 31 offices in Boston, MA. Air samples were analyzed for fluorotelomer alcohols (FTOHs), sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs). Serum was collected from each participant (n = 31) and analyzed for 12 PFCs including PFOA and PFOS. In air, FTOHs were present in the highest concentrations, particularly 8:2-FTOH (GM = 9920 pg/m(3)). FTOHs varied significantly by building with the highest levels observed in a newly constructed building. PFOA in serum was significantly correlated with air levels of 6:2-FTOH (r = 0.43), 8:2-FTOH (r = 0.60), and 10:2-FTOH (r = 0.62). Collectively, FTOHs in air significantly predicted PFOA in serum (p < 0.001) and explained approximately 36% of the variation in serum PFOA concentrations. PFOS in serum was not associated with air levels of FOSAs/FOSEs. In conclusion, FTOH concentrations in office air significantly predict serum PFOA concentrations in office workers. Variation in PFC air concentrations by building is likely due to differences in the number, type, and age of potential sources such as carpeting, furniture, and/or paint.
Zhang, Yong; Xie, Xinfang; Zhao, Xinyuan; Tian, Fang; Lv, Jicheng; Ying, Wantao; Qian, Xiaohong
2018-01-06
Human serum has been intensively studied to identify biomarkers via global proteomic analysis. The altered O-glycoproteome is associated with human pathological state including cancer, inflammatory and degenerative diseases and is an attractive source of disease biomarkers. Because of the microheterogeneity and macroheterogeneity of O-glycosylation, site-specific O-glycosylation analysis in human serum is still challenging. Here, we developed a systematic strategy that combined multiple enzyme digestion, multidimensional separation for sample preparation and high-resolution tandem MS with Byonic software for intact O-glycopeptide characterization. We demonstrated that multiple enzyme digestion or multidimensional separation can make sample preparation more efficient and that EThcD is not only suitable for the identification of singly O-glycosylated peptides (50.3%) but also doubly (21.2%) and triply (28.5%) O-glycosylated peptides. Totally, with the strict scoring criteria, 499 non-redundant intact O-glycopeptides, 173 O-glycosylation sites and 6 types of O-glycans originating from 49 O-glycoprotein groups were identified in human serum, including 121 novel O-glycosylation sites. Currently, this is the largest data set of site-specific native O-glycoproteome from human serum samples. We expect that the strategies developed by this study will facilitate in-depth analyses of native O-glycoproteomes in human serum and provide opportunities to understand the functional roles of protein O-glycosylation in human health and diseases. The altered O-glycoproteome is associated with human pathological state and is an attractive source of disease biomarkers. However, site-specific O-glycosylation analysis is challenging because of the microheterogeneity (different glycoforms attached to one glycosylation site) and macroheterogeneity (site occupancy) of O-glycosylation. In this work, we developed a systematic strategy for intact O-glycopeptide characterization. This study took advantage of the inherent properties of the new fragmentation method called EThcD, which provides more complete fragmentation information about O-glycosylated peptides and a more confident site localization of O-glycans than collision-induced dissociation (HCD). We demonstrated that multiple enzyme digestion or multidimensional separation can make sample preparation more efficient and that EThcD was not only suitable for the identification of singly O-glycosylated peptides (50.3%) but also doubly (21.2%) and triply (28.5%) O-glycosylated peptides. Finally, we got a largest data set of site-specific native O-glycoproteome from human serum samples. Furthermore, quantitative analysis of intact O-glycopeptides from the serum samples of IgA nephropathy (IgAN) patients and healthy donors was performed, and the results showed the potential of the strategy to discover O-glycosylation biomarkers. We expect that the strategies developed by this study will facilitate in-depth analyses of native O-glycoproteomes in human serum and lead to exciting opportunities to understand the functional roles of protein O-glycosylation in human health and diseases. Copyright © 2017. Published by Elsevier B.V.
Chip-LC-MS for label-free profiling of human serum.
Horvatovich, Peter; Govorukhina, Natalia I; Reijmers, Theo H; van der Zee, Ate G J; Suits, Frank; Bischoff, Rainer
2007-12-01
The discovery of biomarkers in easily accessible body fluids such as serum is one of the most challenging topics in proteomics requiring highly efficient separation and detection methodologies. Here, we present the application of a microfluidics-based LC-MS system (chip-LC-MS) to the label-free profiling of immunodepleted, trypsin-digested serum in comparison to conventional capillary LC-MS (cap-LC-MS). Both systems proved to have a repeatability of approximately 20% RSD for peak area, all sample preparation steps included, while repeatability of the LC-MS part by itself was less than 10% RSD for the chip-LC-MS system. Importantly, the chip-LC-MS system had a two times higher resolution in the LC dimension and resulted in a lower average charge state of the tryptic peptide ions generated in the ESI interface when compared to cap-LC-MS while requiring approximately 30 times less (~5 pmol) sample. In order to characterize both systems for their capability to find discriminating peptides in trypsin-digested serum samples, five out of ten individually prepared, identical sera were spiked with horse heart cytochrome c. A comprehensive data processing methodology was applied including 2-D smoothing, resolution reduction, peak picking, time alignment, and matching of the individual peak lists to create an aligned peak matrix amenable for statistical analysis. Statistical analysis by supervised classification and variable selection showed that both LC-MS systems could discriminate the two sample groups. However, the chip-LC-MS system allowed to assign 55% of the overall signal to selected peaks against 32% for the cap-LC-MS system.
Serum adipokines and HIV viral replication in patients undergoing antiretroviral therapy
Aramă, Victoria; Tilişcan, Cătălin; Ion, Daniela Adriana; Mihăilescu, Raluca; Munteanu, Daniela; Streinu-Cercel, Anca; Tudor, Ana Maria; Hristea, Adriana; Leoveanu, Viorica; Olaru, Ioana; Aramă, Ştefan Sorin
2012-01-01
Introduction Several studies have reported that cytokines secreted by adipose tissue (adipokines) may be linked to HIV replication. The aim of the study was to evaluate the relationship between HIV replication and serum levels of adipokines, in a Caucasian HIV-infected population of men and women undergoing complex antiretroviral therapy. Methods A cross-sectional study was conducted in an unselected sample of 77 HIV-1-positive patients. Serum adipokines levels were measured including circulating adiponectin, leptin, resistin, tumor necrosis factor alpha (TNF-alpha) and interleukin-6 (IL-6). Patients were divided into two groups: Group 1 - with undetectable viral load and Group 2 - with persistent HIV viral replication. Differences between groups ? were tested using independent-sample t-test for Gaussian variables and Mann–Whitney–Wilcoxon test for non-parametric variables. Pearson's chi-squared test was used for correlation analysis. Results A total of 77 patients (age range: 17-65, mean: 32.5 years) including 44 men (57.1% men, age range: 17–63 years, mean: 34.1 years) and 33 women (42.9% women age range: 19–65 years, mean: 30.3 years) were included in the study. TNF-alpha had significantly higher serum levels in patients with detectable viral load (16.89 vs. 9.35 pg/mL), (p=0.043), but correlation analysis lacked statistical significance. Adiponectin had median serum levels of 9.22 ìg/mL in Group 1 vs. 16.50 ìg/mL in Group 2 but the results lacked statistical significance (p=0.059). Higher leptin, IL-6 and resistin serum levels were noted in patients with undetectable HIV viral load, without statistical significance. Conclusions The present study reported higher TNF-alpha serum levels in patients with persistent HIV viral load. We found no statistically significant correlations between adiponectin, leptin, resistin and IL-6 and HIV viral load in our Caucasian HIV-positive study population, undergoing antiretroviral therapy. PMID:24432258
Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein
2015-03-01
Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.
Piroozmand, Ahmad; Soltani, Babak; Razavizadeh, Mohsen; Matini, Amir Hasan; Gilasi, Hamid Reza; Zavareh, Abbas Nassaji; Soltani, Siamak
2017-12-01
Helicobacter pylori ( H. pylori ) is an important and common contagious human pathogen which may cause peptic ulcer and also gastric cancer. The definite diagnosis of it is made through invasive tests. Recently, non-invasive tests including serologic tests of serum and saliva have been conducted for diagnosis of H. pylori infection. In this research, the diagnostic values of serum and salivary serology were compared together to use salivary anti- H. pylori test as an alternative method in the future. During this prospective case-control study on patients who were candidates for endoscopy and gastric biopsy from March 2015 to April 2016 in Shahid Beheshti hospital, Kashan, Iran, serum and salivary samples were obtained for measurement of Immunoglobulin G (IgG) antibody levels against H. pylori by enzyme-linked immunosorbent assay (ELISA). Histopathology was the gold standard test. Statistical analysis was performed by SPSS software version 16. Statistical tests included Kolmogorov-Smirnov, independent-samples t-test, Chi-square, Mann-Whitney U, Kruskal-Wallis, McNemar and correlation. Of 123 patients, sixty-one patients (49.6%) were H. pylori -positive according to histology. The median levels of anti- H. pylori antibodies in serum (p<0.001) and saliva (p<0.001) of H. pylori -positive cases were significantly higher than H. pylori -negative cases. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and accuracy of serologic tests in serum were 75%, 79%, 3.5, 0.3, 77% and for saliva were 85%, 82%, 4.7, 0.18, 84% respectively. Diagnostic values of salivary ELISA are comparable to serum ELISA and can be used as an alternative modality for diagnosis of H. pylori infection.
Massive glutamine cyclization to pyroglutamic acid in human serum discovered using NMR spectroscopy.
Nagana Gowda, G A; Gowda, Yashas N; Raftery, Daniel
2015-04-07
Glutamine is one of the most abundant metabolites in blood and is a precursor as well as end product central to numerous important metabolic pathways. A number of surprising and unexpected roles for glutamine, including cancer cell glutamine addiction discovered recently, stress the importance of accurate analysis of glutamine concentrations for understanding its role in health and numerous diseases. Utilizing a recently developed NMR approach that offers access to an unprecedented number of quantifiable blood metabolites, we have identified a surprising glutamine cyclization to pyroglutamic acid that occurs during protein removal. Intact, ultrafiltered and protein precipitated samples from the same pool of human serum were comprehensively investigated using (1)H NMR spectroscopy at 800 MHz to detect and quantitatively evaluate the phenomenon. Interestingly, although glutamine cyclization occurs in both ultrafiltered and protein precipitated serum, the cyclization was not detected in intact serum. Strikingly, due to cyclization, the apparent serum glutamine level drops by up to 75% and, concomitantly, the pyroglutamic acid level increases proportionately. Further, virtually under identical conditions, the magnitude of cyclization is vastly different for different portions of samples from the same pool of human serum. However, the sum of glutamine and pyroglutamic acid concentrations in each sample remains the same for all portions. These unexpected findings indicate the importance of considering the sum of apparent glutamine and pyroglutamic acid levels, obtained from the contemporary analytical methods, as the actual blood glutamine level for biomarker discovery and biological interpretations.
O'Maille, Grace; Go, Eden P.; Hoang, Linh; ...
2008-01-01
Comprehensive detection and quantitation of metabolites from a biological source constitute the major challenges of current metabolomics research. Two chemical derivatization methodologies, butylation and amination, were applied to human serum for ionization enhancement of a broad spectrum of metabolite classes, including steroids and amino acids. LC-ESI-MS analysis of the derivatized serum samples provided a significant signal elevation across the total ion chromatogram to over a 100-fold increase in ionization efficiency. It was also demonstrated that derivatization combined with isotopically labeled reagents facilitated the relative quantitation of derivatized metabolites from individual as well as pooled samples.
Shao, Stephanie; Neely, Benjamin A; Kao, Tzu-Cheg; Eckhaus, Janet; Bourgeois, Jolie; Brooks, Jasmin; Jones, Elizabeth E; Drake, Richard R; Zhu, Kangmin
2017-05-01
Background: Serum proteomic biomarkers offer a promising approach for early detection of cancer. In this study, we aimed to identify proteomic profiles that could distinguish colon cancer cases from controls using serial prediagnostic serum samples. Methods: This was a nested case-control study of active duty military members. Cases consisted of 264 patients diagnosed with colon cancer between 2001 and 2009. Controls were matched to cases on age, gender, race, serum sample count, and collection date. We identified peaks that discriminated cases from controls using random forest data analysis with a 2/3 training and 1/3 validation dataset. We then included epidemiologic data to see whether further improvement of model performance was obtainable. Proteins that corresponded to discriminatory peaks were identified. Results: Peaks with m/z values of 3,119.32, 2,886.67, 2,939.23, and 5,078.81 were found to discriminate cases from controls with a sensitivity of 69% and a specificity of 67% in the year before diagnosis. When smoking status was included, sensitivity increased to 76% while histories of other cancer and tonsillectomy raised specificity to 76%. Peaks at 2,886.67 and 3,119.32 m/z were identified as histone acetyltransferases while 2,939.24 m/z was a transporting ATPase subunit. Conclusions: Proteomic profiles in the year before cancer diagnosis have the potential to discriminate colon cancer patients from controls, and the addition of epidemiologic information may increase the sensitivity and specificity of discrimination. Impact: Our findings indicate the potential value of using serum prediagnostic proteomic biomarkers in combination with epidemiologic data for early detection of colon cancer. Cancer Epidemiol Biomarkers Prev; 26(5); 711-8. ©2016 AACR . ©2016 American Association for Cancer Research.
Association between serum total testosterone and Body Mass Index in middle aged healthy men
Shamim, Muhammad Omar; Ali Khan, Farooq Munfaet; Arshad, Rabia
2015-01-01
Objective: To determine correlation of serum total testosterone with body mass index (BMI) and waist hip ratio (WHR) in healthy adult males. Methods: A cross sectional study was conducted on 200 nonsmoker healthy males (aged 30-50 years) university employees. They were selected by convenience sampling technique after a detailed medical history and clinical examination including BMI and Waist Hip Ratio (WHR) calculation. Blood sampling was carried out to measure serum total testosterone (TT) using facilities of Chemiluminescence assay (CLIA) technique in Dow Chemical Laboratory. Independent sample T test was used for mean comparisons of BMI and WHR in between low and normal testosterone groups. (Subjects having < 9.7 nmol/L of total testosterone in blood were placed in low testosterone group and subjects having ≥ 9.7 nmol/L of total testosterone in blood were placed in normal testosterone group). Correlation of testosterone with BMI and WHR was analyzed by Pearson Correlation. Results: Mean (± SD) age of the subjects included in this study was 38.7 (± 6.563) years mean (± SD) total testosterone was 15.92 (±6.322)nmol/L. The mean (± SD) BMI, and WHR were 24.95 (±3.828) kg/m2 and 0.946 (±0.0474) respectively. Statistically significant differences were observed in the mean values of BMI and WHR for the two groups of testosterone. Significant inverse correlation of serum total testosterone with BMI(r = -0.311, p = 0.000) was recorded in this study. However testosterone was not significantly correlated with waist/hip ratio.(r = -0.126, p = 0.076) Conclusion: Middle age men working at DUHS who have low level of serum total testosterone are more obese than individuals with normal total testosterone level. PMID:26101490
Anti-signal recognition particle autoantibody ELISA validation and clinical associations.
Aggarwal, Rohit; Oddis, Chester V; Goudeau, Danielle; Fertig, Noreen; Metes, Ilinca; Stephens, Chad; Qi, Zengbiao; Koontz, Diane; Levesque, Marc C
2015-07-01
The aim of this study was to develop and validate a quantitative anti-signal recognition particle (SRP) autoantibody serum ELISA in patients with myositis and longitudinal association with myositis disease activity. We developed a serum ELISA using recombinant purified full-length human SRP coated on ELISA plates and a secondary antibody that bound human IgG to detect anti-SRP binding. Protein immunoprecipitation was used as the gold standard for the presence of anti-SRP. Serum samples from three groups were analysed: SRP(+) myositis subjects by immunoprecipitation, SRP(-) myositis subjects by immunoprecipitation and non-myositis controls. The ELISA's sensitivity, specificity, positive predictive value and negative predictive value were evaluated. Percentage agreement and test-retest reliability were assessed. Serial samples from seven SRP immunoprecipitation-positive subjects were also tested, along with serum muscle enzymes and manual muscle testing. Using immunoprecipitation, we identified 26 SRP(+) myositis patients and 77 SRP(-) controls (including 38 patients with necrotizing myopathy). Non-myositis control patients included SLE (n = 4) and SSc (n = 7) patients. Anti-SRP positivity by ELISA showed strong agreement (97.1%) with immunoprecipitation (κ = 0.94). The sensitivity, specificity, positive predictive value, and negative predictive value of the anti-SRP ELISA were 88, 100, 100 and 96, respectively. The area under the curve was 0.94, and test-retest reliability was strong (r = 0.91, P < 0.001). Serial samples showed that anti-SRP levels paralleled changes in muscle enzymes and manual muscle testing. We developed a quantitative ELISA for detecting serum anti-SRP autoantibodies and validated the assay in myositis. Longitudinal assessment of SRP levels by ELISA may be a useful biomarker for disease activity. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Bi, Cong; Zheng, Xiwei; Hage, David S
2016-02-05
In the circulatory system, many drugs are reversibly bound to serum proteins such as human serum albumin (HSA) and alpha1-acid glycoprotein (AGP), resulting in both free and protein-bound fractions for these drugs. This report examined the use of microcolumns containing immobilized AGP for the measurement of free drug fractions by ultrafast affinity extraction and a two-dimensional affinity system. Several drugs known to bind AGP were used as models to develop and evaluate this approach. Factors considered during the creation of this method included the retention of the drugs on the microcolumns, the injection flow rate, the microcolumn size, and the times at which a second AGP column was placed on-line with the microcolumn. The final system had residence times of only 110-830ms during sample passage through the AGP microcolumns and allowed free drug fractions to be determined within 10-20min when using only 3-10μL of sample per injection. This method was used to measure the free fractions of the model drugs at typical therapeutic levels in serum, giving good agreement with the results obtained by ultrafiltration. This approach was also used to estimate the binding constants for each drug with AGP in serum, even for drugs that had significant interactions with both AGP and HSA in such samples. These results indicated that AGP microcolumns could be used with ultrafast affinity extraction to measure free drug fractions in a label-free manner and to study the binding of drugs with AGP in complex samples such as serum. Copyright © 2015 Elsevier B.V. All rights reserved.
Mlynash, Michael; Buckwalter, Marion S; Okada, Ami; Caulfield, Anna Finley; Venkatasubramanian, Chitra; Eyngorn, Irina; Verbeek, Marcel M; Wijman, Christine A C
2013-10-01
In comatose post-cardiac arrest patients, a serum neuron-specific enolase (NSE) level of >33 μg/L within 72 h was identified as a reliable marker for poor outcome in a large Dutch study (PROPAC), and this level was subsequently adopted in an American Academy of Neurology practice parameter. Later studies reported that NSE >33 μg/L is not a reliable predictor of poor prognosis. To test whether different clinical laboratories contribute to this variability, we compared NSE levels from the laboratory used in the PROPAC study (DLM-Nijmegen) with those of our hospital's laboratory (ARUP) using paired blood samples. We prospectively enrolled cardiac arrest patients who remained comatose after resuscitation. During the first 3 days, paired blood samples for serum NSE were drawn at a median of 10 min apart. After standard preparation for each lab, one sample was sent to ARUP laboratories and the other to DLM-Nijmegen. Fifty-four paired serum samples from 33 patients were included. Although the serum NSE measurements correlated well between laboratories (R = 0.91), the results from ARUP were approximately 30% lower than those from DLM-Nijmegen. Therapeutic hypothermia did not affect this relationship. Two patients had favorable outcomes after hypothermia despite NSE levels measured by DLM-Nijmegen as >33 μg/L. Absolute serum NSE levels of comatose cardiac arrest patients differ between laboratories. Any specific absolute cut-off levels proposed to prognosticate poor outcome should not be used without detailed data on how neurologic outcomes correspond to a particular laboratory's method, and even then only in conjunction with other prognostic variables.
Collicutt, Nancy B; Garner, Bridget; Berghaus, Roy D; Camus, Melinda S; Hart, Kelsey
2015-03-01
Although delays between blood sample collection and analysis are common in veterinary medicine, the effect of prolonged serum-clot contact time on serum glucose concentration is not well established and species differences have not been elucidated. The objective was to investigate the effect of storage time and temperature on serum glucose concentration in stored whole blood samples from horse, dog, alpaca, and sturgeon. Whole blood specimens were divided into 7 no-additive tubes and serum was separated from one sample within one hour, serving as the reference sample. The remaining samples were stored at 4°C and 25°C, then centrifuged and serum glucose measured by automated analysis at 2, 4, and 8 hours postcollection. Glucose concentrations were compared using linear mixed models. The decline in serum glucose concentration for all samples stored at 4°C was not statistically significant, except for the 8-hour samples from sturgeon and dog. At 25°C, serum glucose concentration was comparable to reference values at 2 hours in sturgeon and alpaca, but significantly lower at 4 and 8 hours in those species, and at all time points in equine and canine specimens, being most prominent after 8 hours of storage in canine specimens. Storage at 4°C limits serum glucose decline for at least 4 hours in all species tested and up to 8 hours in specimens of horse and alpaca. At 25°C, serum-clot contact time should not exceed 1 hour in equine and canine samples, and 2 hours in specimens from alpaca and sturgeon. © 2014 American Society for Veterinary Clinical Pathology.
Schirtzinger, Erin E; Suddith, Andrew W; Hause, Benjamin M; Hesse, Richard A
2015-10-16
Currently, eight species in four genera of parvovirus have been described that infect swine. These include ungulate protoparvovirus 1 (classical porcine parvovirus, PPV), ungulate tetraparvovirus 2 (PPV3), ungulate tetraparvovirus 3 (which includes PPV2, porcine hokovirus, porcine partetravirus and porcine PARV4), ungulate copiparvovirus 2 (which includes PPV4 and PPV5), ungulate bocaparvovirus 2 (which includes porcine bocavirus 1, 2 and 6), ungulate bocaparvovirus 3 (porcine bocavirus 5), ungulate bocaparvovirus 4 (porcine bocavirus 7) and ungulate bocaparvovirus 5 (porcine bocavirus 3, 4-1 and 4-2). PPV6, the most recently described porcine parvovirus, was first identified in China in late 2014 in aborted pig fetuses. Prevalence of PPV6 in China was found to be similar in finishing age pigs from farms with and without evidence of swine reproductive failure. Porcine parvovirus 6 (PPV6) was detected by sequence-independent single primer amplification (SISPA) and confirmed by overlapping and real-time PCR in the serum of porcine reproductive and respiratory virus (PRRSv) positive samples. Seven nearly complete genomes of PPV6 were identified in PRRSv genotype 2 positive serum samples submitted to state veterinary diagnostic laboratories in 2014. Further testing using overlapping and real-time PCR determined PPV6 to be present in 13.2 % of the serums tested. Additionally, PPV6 was present in samples from all of the geographic locations sampled encompassing nine states in the United States and one state in Mexico. The presence of PPV6 in serum indicates that the PPV6 infection is disseminated and not localized to a specific tissue type. Alignments of the near full length genomes, NS1, and capsid genes identified one of the five PPV6 isolates from China (98.6-99.5 % identity with the North American strains) to be the North American strains nearest relative. These results are the first to report the presence of PPV6 in North America and demonstrate that the virus is found in multiple geographic areas in the United States and in Mexico. The overall prevalence of PPV6 in PRRSv viremic animals is relatively low. Further, all of the PPV6 genomes found in North America are most closely related to a PPV6 strain first identified in 2014 in healthy pigs from the Tianjin province of China.
Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R.; Fernandes, Daryl L.; Satsangi, Jack; Spencer, Daniel I. R.
2015-01-01
Introduction Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. Methods 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. Results There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. Conclusions The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures. PMID:25831126
Ventham, Nicholas T; Gardner, Richard A; Kennedy, Nicholas A; Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R; Fernandes, Daryl L; Satsangi, Jack; Spencer, Daniel I R
2015-01-01
Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures.
IL8 and IL16 levels indicate serum and plasma quality.
Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay
2018-02-09
Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.
Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.
Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H
2013-10-01
Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.
Frölich, K; Li, H; Müller-Doblies, U
1998-10-01
A total of 486 serum samples collected from several species of both free-living and captive cervids in Germany was examined for antibodies against malignant catarrhal fever (MCF)-associated viruses (MCFV) by a competitive-inhibition enzyme-linked immunosorbent assay (CI-ELISA). Eleven (2%) of these samples were positive for antibodies against MCFV. Among 157 serum samples collected from 16 different species of captive deer including four (7%) of 54 fallow deer and one (7%) of 14 sika deer (Cervus nippon) were seropositive. Among 329 samples from three species of free-ranging deer, including 253 roe deer (Capreolus capreolus), 22 red deer (Cervus elaphus) and 54 fallow deer (Cervus dama), only fallow deer were antibody-positive. Of the 25 fallow deer samples collected between 1990 and 1993, four (16%) were seropositive. Among 29 free-ranging fallow deer samples collected in the hunting period 1996-1997, antibodies to MCFV were detected in two (7%) of these sera. All of these fallow deer samples were collected from a circumscribed area in northern Germany. In the same area a high seroprevalence (72%) to MCFV was observed in domestic sheep (n = 50). Among 20 sheep samples (buffy coat) and 15 fallow deer samples (spleen or lymph nodes) examined for ovine herpesvirus 2 (OvHV-2) by PCR, all 20 sheep samples examined were OvHV-2 positive, but all of the 15 fallow deer samples, including seven seropositive deer, were OvHV-2 negative.
Joulié, A.; Rousset, E.; Gasqui, P.; Lepetitcolin, E.; Leblond, A.; Sidi-Boumedine, K.
2017-01-01
ABSTRACT The control of Q fever, a zoonotic disease caused by the Coxiella burnetii bacterium, remains a scientific challenge. Domestic ruminants are considered the main reservoir, shedding C. burnetii essentially through parturition products during abortion or birth. Sheep are particularly frequently associated with human outbreaks, but there are insufficient field data to fully understand disease dynamics and to instigate efficient control measures. A longitudinal follow-up study of a naturally infected sheep flock was performed (i) to investigate relationships between seropositivity and bacterial shedding in the vaginal mucus, (ii) to describe the kinetics of antibodies, including responses to vaccination, (iii) to monitor maternal antibodies in ewe lambs, and (iv) to compare serological results for milk and serum samples. For 8 months, we collected blood samples every 3 weeks from 11 aborting and 26 nonaborting dairy ewes, 20 nonaborting suckler ewes, and 9 ewe lambs. Individual milk samples were also obtained from lactating females. All serum and milk samples were tested by enzyme-linked immunosorbent assay (ELISA), whereas vaginal swabs were tested by quantitative PCR. We found that some dairy females did not seroconvert despite shedding C. burnetii in their vaginal mucus. Overall, antibody levels in adult females were found to remain stable over time, with exceptions during the mating and lambing periods. Maternal antibodies decreased during the first month after birth. Interestingly, antibody levels in milk were correlated with those in serum. This study provides valuable field data that will help improve Q fever surveillance and within-flock management measures. IMPORTANCE Field data are necessary to improve the surveillance, diagnosis, and sanitary management of Q fever in livestock. Here, we provide extensive serological data obtained from serum and milk samples from infected and vaccinated ewes belonging to a naturally infected flock of sheep. We show that antibody levels are stable over time and seropositivity and vaginal shedding are not clearly correlated, whereas antibody levels in milk are strongly correlated with those in serum. Accordingly, we find that antibody levels in bulk tank milk are consistent with the variations observed in the serum of dairy females over time. We report the existence of maternal antibody transmission to ewe lambs and we show that the presence of maternal antibodies at birth does not prevent the development of a serological response to vaccination at the age of 4 months. Finally, we report that adult ewes generally seroconvert after vaccination, including during pregnancy. PMID:28455328
Joulié, A; Rousset, E; Gasqui, P; Lepetitcolin, E; Leblond, A; Sidi-Boumedine, K; Jourdain, E
2017-07-01
The control of Q fever, a zoonotic disease caused by the Coxiella burnetii bacterium, remains a scientific challenge. Domestic ruminants are considered the main reservoir, shedding C. burnetii essentially through parturition products during abortion or birth. Sheep are particularly frequently associated with human outbreaks, but there are insufficient field data to fully understand disease dynamics and to instigate efficient control measures. A longitudinal follow-up study of a naturally infected sheep flock was performed (i) to investigate relationships between seropositivity and bacterial shedding in the vaginal mucus, (ii) to describe the kinetics of antibodies, including responses to vaccination, (iii) to monitor maternal antibodies in ewe lambs, and (iv) to compare serological results for milk and serum samples. For 8 months, we collected blood samples every 3 weeks from 11 aborting and 26 nonaborting dairy ewes, 20 nonaborting suckler ewes, and 9 ewe lambs. Individual milk samples were also obtained from lactating females. All serum and milk samples were tested by enzyme-linked immunosorbent assay (ELISA), whereas vaginal swabs were tested by quantitative PCR. We found that some dairy females did not seroconvert despite shedding C. burnetii in their vaginal mucus. Overall, antibody levels in adult females were found to remain stable over time, with exceptions during the mating and lambing periods. Maternal antibodies decreased during the first month after birth. Interestingly, antibody levels in milk were correlated with those in serum. This study provides valuable field data that will help improve Q fever surveillance and within-flock management measures. IMPORTANCE Field data are necessary to improve the surveillance, diagnosis, and sanitary management of Q fever in livestock. Here, we provide extensive serological data obtained from serum and milk samples from infected and vaccinated ewes belonging to a naturally infected flock of sheep. We show that antibody levels are stable over time and seropositivity and vaginal shedding are not clearly correlated, whereas antibody levels in milk are strongly correlated with those in serum. Accordingly, we find that antibody levels in bulk tank milk are consistent with the variations observed in the serum of dairy females over time. We report the existence of maternal antibody transmission to ewe lambs and we show that the presence of maternal antibodies at birth does not prevent the development of a serological response to vaccination at the age of 4 months. Finally, we report that adult ewes generally seroconvert after vaccination, including during pregnancy. Copyright © 2017 American Society for Microbiology.
Comparison of Schmallenberg virus antibody levels detected in milk and serum from individual cows.
Daly, Janet M; King, Barnabas; Tarlinton, Rachael A; Gough, Kevin C; Maddison, Ben C; Blowey, Roger
2015-03-11
Schmallenberg virus (SBV) is a recently emerged virus of ruminants in Europe. Enzyme-linked immunosorbent assays (ELISA) are commonly used to detect SBV-specific antibodies in bulk tank milk samples to monitor herd exposure to infection. However, it has previously been shown that a bulk tank milk sample can test positive even though the majority of cows within the herd are seronegative for SBV antibodies. Development of a pen-side test to detect antibodies in individual milk samples would potentially provide a cheaper test (for which samples are obtained non-invasively) than testing individual serum samples by ELISA. Therefore, the aim of this study was to investigate the agreement between antibody levels measured in milk and serum. Corresponding milk and serum samples from 88 cows in two dairy herds in the UK were tested for presence of immunoglobulin G antibodies to SBV using a commercially-available indirect ELISA. A serum neutralisation test (NT) was also performed as a gold standard assay. The ELISA values obtained for the bulk tank milk samples corresponded with the mean values for individual milk samples from each herd (bulk tank milk values were 58% and 73% and mean individual milk values 50% and 63% for herds A and B, respectively). Of the 88 serum samples tested in the NT, 82 (93%) were positive. Although at higher antibody levels, the ELISA values tended to be higher for the individual milk samples than for the corresponding serum samples, the positive predictive value for milk samples was 98% and for serum samples 94%. The serum ELISA was more likely to give false positive results around the lower cut-off value of the assay. The results indicate that testing of individual milk samples for antibodies against SBV by ELISA could be used to inform decisions in the management of dairy herds such as which, if any, animals to vaccinate.
Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin
2014-01-01
Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.
Dukić, Lora; Šimundić, Ana-Maria; Malogorski, Davorin
2014-01-01
Introduction: Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Materials and methods: Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Results: Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Conclusion: Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration. PMID:24627723
Biomonitoring of selenoprotein P in human serum by fast affinity chromatography coupled to ICP-MS.
Heitland, Peter; Köster, Helmut D
2018-04-01
Most of the Se in human serum is bound to selenoprotein P (SEPP1) in which Se is present in form of selenocysteine. The SEPP1 is a new possible biomarker for the Se status and for this reason we developed a fast, simple and reliable method for the quantitative determination of SEPP1 in serum by affinity chromatography coupled to ICP-MS. It is possible to separate SEPP1 from other selenoproteins in serum in only 5 min, which allows high sample throughput in clinical laboratories. Measured and certified concentrations of total Se and Se(SEPP1) are in good agreement for the reference material SRM 1950. The SEPP1 concentration was stable in serum samples of 3 persons for a minimum of 2 weeks. Further results of method validation were described including internal and external quality assurance. The analytical method was applied for a biomonitoring study of the SEPP1 and total Se concentration in human serum of 50 occupationally non-exposed persons living in northern Germany. Concentration ranges and mean concentrations for Se(SEPP1) are 31.1-59.7 and 46.2 μg/L, respectively. The corresponding values for total Se are 62-120 and 83.5 μg/L. The mean percentage of total Se in serum present as SEPP1 is 58%. Copyright © 2018 Elsevier GmbH. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.
2012-08-03
Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the developmentmore » of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.« less
Zhou, Tong; Yang, Rupu; Li, Shihong; Zheng, Guoqing; Xi, Yu; Cheng, Xuemin; Hou, Jiaxiang; Cui, Liuxin; Ba, Yue
2013-03-01
To explore the influence of water fluoride exposure on sex hormone binding globulin (SHBG) and testosterone in adult male. Cross-sectional study was conducted in three villages of Tongxu county including high fluoride group (HFG), defluoridation project group (DFPG) and control group (CG) based on the fluoride concentration in drinking water. Adult male who were born and raised in the village and aged 18 - 50 years old were recruited using cluster sampling. Fasting blood and morning urine samples were collected. The fluoride levels in drinking water and urine were detected by fluoride-ion selective electrode method. Serum SHBG level was determined using enzyme-linked immunosorbent assay (ELISA). The chemical luminescence immune analysis method was used to detect serum testosterone content. Serum SHBG level was 47.85 nmol/L in CG, 31.37 nmol/L in DFPG and 24.52 nmol/L in HFG respectively. There were significant difference among of three groups (P < 0.05). Serum testosterone level was 3.69 ng/ml in CG, 4.61 ng/ml in DFPG and 4.83 ng/ml in HFG respectively. Serum testosterone level in HFG was significantly higher than that in CG (P < 0.05). Serum SHBG level in HFG has positive correlation with serum testosterone (r = 0.230, P = 0.049), which has not been observed in DFPG and CG. Long-time fluorine exposure may affect serum SHBG and testosterone level in adult male.
Gresa-Arribas, Nuria; Titulaer, Maarten J; Torrents, Abiguei; Aguilar, Esther; McCracken, Lindsey; Leypoldt, Frank; Gleichman, Amy J; Balice-Gordon, Rita; Rosenfeld, Myrna R; Lynch, David; Graus, Francesc; Dalmau, Josep
2014-02-01
Anti-N-methyl-d-aspartate (NMDA) receptor encephalitis is a severe but treatable autoimmune disorder which diagnosis depends on sensitive and specific antibody testing. We aimed to assess the sensitivity and specificity of serum and CSF antibody testing in patients with anti-NMDA receptor encephalitis, and the relation between titres, relapses, outcome, and epitope repertoire. In this observational study, we used rat brain immunohistochemistry and cell-based assays (CBA) with fixed or live NMDA receptor-expressing cells to determine the sensitivity and specificity of antibody testing in paired serum and CSF samples. Samples were obtained at diagnosis from patients with anti-NMDA receptor encephalitis and from control participants worldwide. We deemed a patient to be antibody positive if their serum, their CSF, or both tested positive with both immunohistochemistry and CBA techniques; we determined titres with serial sample dilution using brain immunohistochemistry. We examined samples from 45 patients (25 with good outcome [modified Rankin Scale, mRS 0-2], ten with poor outcome [mRS 3-6], and ten with relapses) at three or more timepoints. We determined the epitope repertoire in the samples of 23 patients with CBA expressing GluN1-NMDA receptor mutants. We analysed samples from 250 patients with anti-NMDA receptor encephalitis and 100 control participants. All 250 patients had NMDA receptor antibodies in CSF but only 214 had antibodies in serum (sensitivity 100.0% [98.5-1000%] vs 85.6% [80.7-89.4%], p<0.0001). Serum immunohistochemistry testing was more often in agreement with CBA with fixed cells (77 [71%] of 108) than with CBA with live cells (63 [58%] of 108, p=0.0056). In multivariable analysis, CSF and serum titres were higher in patients with poor outcome than in those with good outcome (CSF dilution 340 vs 129, difference 211, [95% CI 1-421], p=0.049; serum dilution 7370 vs 1243, difference 6127 [2369-9885], p=0.0025), and in patients with teratoma than in those without teratoma (CSF 395 vs 110, difference 285 [134-437], p=0.0079; serum 5515 vs 1644, difference 3870 [548-7193], p=0.024). Over time there was a decrease of antibody titres in the 35 patients with good or poor outcome and samples followed at three timepoints regardless of outcome (from diagnosis to last follow-up: CSF 614 to 76, difference 538 [288-788]; serum 5460 to 1564, difference 3896 [2428-5362]; both p<0.0001). Relapses were associated with a change in titre more often in CSF than in serum (14 of 19 vs seven of 16, p=0.037). After recovery, 24 of 28 CSF samples and 17 of 23 serum samples from patients remained antibody positive. Patients' antibodies targeted a main epitope region at GluN1 aminoacid 369; the epitope repertoire did not differ between patients with different outcomes, and did not change during relapses. The sensitivity of NMDA receptor antibody testing is higher in CSF than in serum. Antibody titres in CSF and serum were higher in patients with poor outcome or teratoma than in patients with good outcome or no tumour. The titre change in CSF was more closely related with relapses than was that in serum. These findings emphasise the importance of including CSF in antibody studies, and that antibody titres can complement clinical assessments. Dutch Cancer Society, National Institutes of Health, McKnight Neuroscience of Brain Disorders award, the Fondo de Investigaciones Sanitarias, ErasmusMC fellowship, and Fundació la Marató de TV3. Copyright © 2014 Elsevier Ltd. All rights reserved.
YAMAMOTO, Kenya; KUDO, Mitsuhiro; ARITO, Heihachiro; OGAWA, Yasutaka; TAKATA, Tsutomu
2015-01-01
This cross-sectional study was intended to examine health effects of 678 male workers employed during an 8-yr period from 2000 to 2007 at 36 municipal and private waste incineration plants in Japan. Blood samples were obtained for analysis of concentrations of dioxins including coplanar polychlorinated biphenyls (coplanar PCBs) and evaluation of health effects. Health effects including diabetes were surveyed via a physician’s interview or clinical data from blood samples. There was a certain difference in serum concentrations of polychlorinated dibenzofurans (PCDFs) between the incinerator workers and Japanese general population, although no differences in the concentrations of total dioxins or polychlorinated dibenzo-p-dioxins (PCDDs) were found between the two groups. A few positive correlations between serum levels of PCDDs and PCDFs and the results of laboratory and physiological tests were found, but coplanar PCBs showed significant relations with 14 parameters of the tests. The background serum levels of PCDDs, PCDFs and total dioxins were significantly associated with the prevalence of diabetes. No essential differences in serum concentrations of total dioxins and in prevalence of diabetes between our subjects and the general population suggested that the incinerator workers were marginally exposed to dioxins in the workplace without any recognizable adverse health effects. PMID:26212412
Yamamoto, Hiroshi; Li, Tian-Cheng; Koshimoto, Chihiro; Ito, Kaori; Kita, Masakazu; Miyashita, Nobumoto; Arikawa, Jiro; Yagami, Kenichi; Asano, Masahide; Tezuka, Hideo; Suzuki, Noboru; Kurosawa, Tsutomu; Shibahara, Toshiyuki; Furuya, Masato; Mohri, Shirou; Sato, Hiroshi; Ohsawa, Kazutaka; Ibuki, Kentaro; Takeda, Naokazu
2008-07-01
In laboratory animal facilities, monkeys and pigs are used for animal experiments, but the details of hepatitis E virus (HEV) infection in these animals are unknown. The risk of infection from laboratory animals to humans has become a concern; therefore, much attention should be paid to the handling of these animals during their care and use, including surgical procedures performed on infected animals. In this connection, serum samples collected from 916 monkeys and 77 pigs kept in 23 animal facilities belonging to the Japanese Association of Laboratory Animal Facilities of National University Corporations (JALAN) and the Japanese Association of Laboratory Animal Facilities of Public and Private Universities (JALAP) in Japan were examined for the purpose of detecting antibodies to HEV and HEV RNA by using ELISA and RT-PCR, respectively. One hundred and seven serum samples of 916 (11.7%) monkeys were positive for anti-HEV IgG, and 7 and 17 serum samples of 916 (0.8% and 5.3%) monkeys were positive for anti-HEV IgM and IgA, respectively. Thirty-six samples from 62 (58.1%) farm pigs were positive for anti-HEV IgG, whereas all samples tested from miniature pigs were negative (0/15, 0%). Seven samples from 62 (9.1%) farm pigs and 7 samples from 916 (0.8%) monkeys were positive for IgM antibody, but these HEV-IgM antibody positive serum samples were HEV-RNA negative by RT-PCR. The IgM antibody positive rate (9.1%) of farm pigs was much higher than that of monkeys (0.8%). These results suggest the relative levels of risk of HEV infection from these animals to animal handlers and researchers who work with them in laboratory animal facilities.
Cundy, Thomas P; Cundy, William J; Antoniou, Georgia; Sutherland, Leanne M; Freeman, Brian J C; Cundy, Peter J
2014-11-01
Measurement of serum metal ion levels is used to determine systemic exposure to implant-derived metal debris that may be generated by processes of wear and corrosion. The aim of this study is to investigate predictors of serum metal ion levels in children undergoing instrumented spinal arthrodesis using a titanium alloy, focusing on implant characteristics and instrumentation construct design variables. This prospective longitudinal cohort study involved 33 children. Serum samples were obtained preoperatively:and at five defined interval periods over the first:two post-operative years. Samples were analysed using high resolution:inductively coupled plasma mass spectrometry to measure titanium, niobium and aluminium concentrations. Instrumentation characteristics were catalogued and construct surface area (SA) measurements calculated using an implant-specific software algorithm tool. Significantly elevated levels of serum titanium and niobium were observed (p< 0.0001), with >95 % of post-operative levels abnormally elevated. Significant predictors of serum titanium and niobium levels included time since surgery, surgical procedure (posterior or anterior fusion), number of levels fused, number of pedicle screws inserted, total rod length, total metal SA, total exposed metal SA and total metal-on-metal SA. All significant instrumentation variables were highly correlated. There is a strong relationship between implant SA and both serum titanium and niobium levels. The direct clinical implications of these findings for patients are uncertain, but remain of concern. Surgeons should be aware of the strong correlation between implant surface area of the chosen construct and the subsequent serum metal ion levels.
Systematic evaluation of serum and plasma collection on the endogenous metabolome.
Zhou, Zhi; Chen, Yanhua; He, Jiuming; Xu, Jing; Zhang, Ruiping; Mao, Yan; Abliz, Zeper
2017-02-01
In metabolomics research, the use of different blood collection methods may influence endogenous metabolites. Ultra HPLC coupled with MS/MS was applied together with multivariate statistics to investigate metabolomics differences in serum and plasma samples handled by different anticoagulants. A total of 135 known representative metabolites were assessed for comprehensive evaluation of the effects of anticoagulants. Exogenous factors, including separation gel ingredients from the serum collection tubes and the anticoagulants, affected mass spectrometer detection. Heparin plasma yielded the best detection of different functional groups and is therefore the optimal blood specimen for metabolomics research, followed by potassium oxalate plasma.
Serum uric acid as prognostic marker of coronary heart disease (CHD).
Purnima, Samudrala; El-Aal, Bahiga Galal Abd
A substantial body of epidemiological and experimental evidence suggests the significance of serum uric acid as an important and independent risk factor of cardio vascular and renal diseases especially in patients with diabetes mellitus, hypertension. Hyperuricemia is a risk factor of coronary heart disease. Several studies showed positive association between hyperuricemia and CHD risk factors. To analyze the serum uric acid levels in patients with diabetes and hypertension, which helps in understanding its role as prognostic marker of coronary heart disease. The study was conducted in population of Wadi-Al Dawasir (K.S.A.) aged 20-80 years through random sampling from October 2012 to June 2013. It included 250 samples and the cases were categorized into diabetic and hypertensive. In the cases, purely hypertensive were 52, diabetic were 57 and mixed group included both diabetic and hypertensive patients 65. Fasting blood was collected to analyze lipid profile which included (total cholesterol, triglycerides, high density lipoprotein, low density lipoprotein) and serum uric acid in association with age and heredity was also studied. Patient demographics were recorded. The study revealed significant association of serum uric acid (p<0.014*) and total cholesterol (p<0.007**) triglycerides (p<0.009**) low density lipoprotein (p<0.044*) in hypertensive group. Serum uric acid levels in the mixed group patients with diabetes and hypertension reported serum uric acid (p<0.0037), total cholesterol (p<0.089+) proved to have increased risk of coronary heart disease. When compared to controls (non-diabetic p<0.529) and (non-hypertensive p<0.021*) with respect to serum uric acid levels show the magnitude of risk to coronary heart disease. With progressing age the association of lipid profile and serum uric acid reported (p<0.001**) in diabetics. Significant correlations were found between serum uric acid and risk factors for CHD. This is first study of its kind in this region of K.S.A., which helps the community to understand the role of serum uric acid in coronary heart disease, justifies the objective of research in taking preventive measures to combat the deleterious effect of coronary heart disease. Prevention and early detection of elevated uric acid in both hypertensive and diabetic patients could serve as effective investigative tool in reducing coronary heart disease. Copyright © 2016 Sociedad Española de Arteriosclerosis. Publicado por Elsevier España, S.L.U. All rights reserved.
Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong
2017-01-01
Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime, laboratorians must remain alert to the negative interference by rheumatoid factor, and in some cases, pretreat rheumatoid factor-positive samples with blocking or absorbing reagents.
Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing
2015-01-01
Objective Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Methods Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. Results A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. Conclusion A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC. PMID:26487969
Therapeutic drug monitoring of caffeine in preterm infants: Could saliva be an alternative to serum?
Chaabane, Amel; Chioukh, Fatma Z; Chadli, Zohra; Ben Fredj, Nadia; Ben Ameur, Karim; Ben Hmida, Hayet; Boughattas, Naceur A; Monastiri, Kamel; Aouam, Karim
2017-12-01
Evaluate whether saliva could be a useful alternative to serum for routine therapeutic drug monitoring of caffeine in preterm infants using the enzyme multiplied immunoassay technique (EMIT) assay. We conducted a prospective study including preterm infants (less than 34 weeks' amenorrhea) admitted to the intensive care and neonatal medicine department. All infants received 5, 10, 15, 20 and 25mg/kg/day of citrate caffeine intravenously from the first to the fifth day of birth, respectively. For each patient, two concomitant blood and saliva samples corresponding to the trough concentrations were collected 24hours after each caffeine dose. The caffeine concentrations were determined using the EMIT ® 2000 caffeine assay. Thirteen preterm infants were included. The saliva and the serum caffeine concentration increased proportionally to the administered dose. Saliva and serum kinetics were comparable and the saliva caffeine concentrations were correlated to the serum ones (r 2 =0.76). Saliva caffeine monitoring by EMIT is a valid, useful and safe alternative to serum in preterm infants. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.
Chen, Rui; Tan, Yexiong; Wang, Min; Wang, Fangjun; Yao, Zhenzhen; Dong, Liwei; Ye, Mingliang; Wang, Hongyang; Zou, Hanfa
2011-01-01
A robust, reproducible, and high throughput method was developed for the relative quantitative analysis of glycoprotein abundances in human serum. Instead of quantifying glycoproteins by glycopeptides in conventional quantitative glycoproteomics, glycoproteins were quantified by nonglycosylated peptides derived from the glycoprotein digest, which consists of the capture of glycoproteins in serum samples and the release of nonglycopeptides by trypsin digestion of captured glycoproteins followed by two-dimensional liquid chromatography-tandem MS analysis of released peptides. Protein quantification was achieved by comparing the spectrum counts of identified nonglycosylated peptides of glycoproteins between different samples. This method was demonstrated to have almost the same specificity and sensitivity in glycoproteins quantification as capture at glycopeptides level. The differential abundance of proteins present at as low as nanogram per milliliter levels was quantified with high confidence. The established method was applied to the analysis of human serum samples from healthy people and patients with hepatocellular carcinoma (HCC) to screen differential glycoproteins in HCC. Thirty eight glycoproteins were found with substantial concentration changes between normal and HCC serum samples, including α-fetoprotein, the only clinically used marker for HCC diagnosis. The abundance changes of three glycoproteins, i.e. galectin-3 binding protein, insulin-like growth factor binding protein 3, and thrombospondin 1, which were associated with the development of HCC, were further confirmed by enzyme-linked immunosorbent assay. In conclusion, the developed method was an effective approach to quantitatively analyze glycoproteins in human serum and could be further applied in the biomarker discovery for HCC and other cancers. PMID:21474793
Reference measurement procedure for total glycerides by isotope dilution GC-MS.
Edwards, Selvin H; Stribling, Shelton L; Pyatt, Susan D; Kimberly, Mary M
2012-04-01
The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum. We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [(13)C(3)]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b). The calibration response was linear for the range of calibrator concentrations examined (0-1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123-0.7225) and 0.3122 (95% CI, 0.3096-0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%. This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.
Colón, I; Caro, D; Bourdony, C J; Rosario, O
2000-01-01
Premature breast development (thelarche) is the growth of mammary tissue in girls younger than 8 years of age without other manifestations of puberty. Puerto Rico has the highest known incidence of premature thelarche ever reported. In the last two decades since this serious public health anomaly has been observed, no explanation for this phenomenon has been found. Some organic pollutants, including pesticides and some plasticizers, can disrupt normal sexual development in wildlife, and many of these have been widely used in Puerto Rico. This investigation was designed to identify pollutants in the serum of Puerto Rican girls with premature thelarche. A method for blood serum analysis was optimized and validated using pesticides and phthalate esters as model compounds of endocrine-disrupting chemicals. Recovery was > 80% for all compounds. We performed final detection by gas chromatography/mass spectrometry. We analyzed 41 serum samples from thelarche patients and 35 control samples. No pesticides or their metabolite residues were detected in the serum of the study or control subjects. Significantly high levels of phthalates [dimethyl, diethyl, dibutyl, and di-(2-ethylhexyl)] and its major metabolite mono-(2-ethylhexyl) phthalate were identified in 28 (68%) samples from thelarche patients. Of the control samples analyzed, only one showed significant levels of di-isooctyl phthalate. The phthalates that we identified have been classified as endocrine disruptors. This study suggests a possible association between plasticizers with known estrogenic and antiandrogenic activity and the cause of premature breast development in a human female population. PMID:11017896
el-Zoghbi, M; Sitohy, M Z
2001-04-01
Male albino rats were fed diets contained 6.85% mineral salts for 2 weeks (adaptation condition). Then they were fed the dietary pectin administered diet for 6 weeks to evaluate the effect of administration of pectin on the absorption of some monovalent, bivalent and heavy metals in the serum of rats. The experimental parameters included, monovalent minerals (K, Na), bivalent minerals (Zn, Cu, Ca, Fe), heavy metals (Pb, Cd), serum uric acid and serum creatinine. The obtained results indicated that the serum contents of monovalent minerals were negatively affected by pectin administration. The low degree of esterification of pectin was more effective on the absorption of bivalent minerals. Also, the rat serum levels of lead and cadmium were reduced by pectin administration. Serum total proteins were reduced by pectin administration. The level of rat serum of uric acid and creatinine fed different sources of pectin were within normal levels and were insignificantly lower than that recorded for control samples.
Serum protein electrophoretic pattern in one-humped camels (Camelus dromedarius) in Tripoli, Libya.
Abdoslam, Omran; Bayt-Almal, Mahmoud; Almghrbe, Abdullah; Algriany, Omran
2018-01-01
The aim of this study was to characterize serum protein capillary electrophoretic pattern in apparently healthy adult male (age: 3-7 years) dromedary camels and also evaluate total protein and albumin levels using automated analyzer. Blood samples were taken from 20 camels. 5ml of blood was collected from the jugular vein and serum was separated from samples by centrifugation. Capillary electrophoresis of serum proteins identified six protein fractions in adult camels, including albumin, alpha1, alpha2, beta1, beta2 and gamma globulins, serum levels of these parameters were 3.9±0.04 g/dl, 0.16±0.01 g/dl, 0.39±0.03 g/dl, 0.515±0.03 g/dl, 0.205±0.01 g/dl and 0.61±0.04 g/dl, and 65.42±0.62 g/l, respectively. The total protein concentration was 65.42±0.62 g/L, while, the albumin/globulin (A/G) ratio was 2.4±0.14. The present study indicates six peaks with minicapillary electrophoresis and the results obtained were compared and interpreted in the light of finding reported by other investigators in camels.
Hosotani, Keisuke; Kitagawa, Masahiro
2003-07-05
Among the many simultaneous determination methods for carotenoid and retinoid, there are only a few reports including the saponification process. However, the yields of beta-carotene and retinol were higher when using this process. In this study, the analytical conditions, including saponification, were investigated. The extraction solvent was n-hexane and the sample solvent was HPLC mobile phase in the beta-carotene and retinol analysis. BHT as an antioxidant was added at concentrations of 0.125 and 0.025%, respectively, to ethanol and n-hexane phase in the extraction process for serum. The recovery rates were 99.7, 93.7 and 98.3% for beta-carotene, retinol and retinyl palmitate in serum, respectively, and 107.1, 92.8 and 98.8% for beta-carotene, retinol and retinyl palmitate in liver, respectively. The within-day coefficients of variation (C.V.) were 6.0% for serum and 4.7% for liver in the case of beta-carotene, 7.1% for serum, and 5.1% for liver in the case of retinol. The between-day coefficients of variation were 2.7% for serum and 2.7% for liver in the case of beta-carotene, and for retinol, 6.4% for serum and 2.7% for liver.
Kittawornrat, Apisit; Panyasing, Yaowalak; Goodell, Christa; Wang, Chong; Gauger, Phillip; Harmon, Karen; Rauh, Rolf; Desfresne, Luc; Levis, Ian; Zimmerman, Jeffrey
2014-01-31
Oral fluid samples collected from litters of piglets (n=600) one day prior to weaning were evaluated as a method to surveil for porcine reproductive and respiratory syndrome virus (PRRSV) infections in four sow herds of approximately 12,500 sow each. Serum samples from the litters' dam (n=600) were included for comparison. All four herds were endemically infected with PRRSV and all sows had been vaccinated ≥ 2 times with PRRSV modified-live virus vaccines. After all specimens had been collected, samples were randomized and assayed by PRRSV real-time reverse transcription polymerase chain reaction (RT-qPCR) and four PRRSV antibody ELISA assays (IgM, IgA, IgG, and Commercial Kit). All sow serum samples were negative by PRRSV RT-qPCR, but 9 of 600 oral fluid samples tested positive at two laboratories. Open reading frame 5 (ORF5) sequencing of 2 of the 9 positive oral fluid samples identified wild-type viruses as the source of the infection. A comparison of antibody responses in RT-qPCR positive vs. negative oral fluid samples showed significantly higher IgG S/P ratios in RT-qPCR-positive oral fluid samples (mean S/P 3.46 vs. 2.36; p=0.02). Likewise, sow serum samples from RT-qPCR-positive litter oral fluid samples showed significantly higher serum IgG (mean S/P 1.73 vs. 0.98; p<0.001) and Commercial Kit (mean S/P 1.97 vs. 0.98; p<0.001) S/P ratios. Overall, the study showed that pre-weaning litter oral fluid samples could provide an efficient and sensitive approach to surveil for PRRSV in infected, vaccinated, or presumed-negative pig breeding herds. Copyright © 2014 Elsevier B.V. All rights reserved.
Specific IgA and IgG antibodies in paired serum and breast milk samples in human strongyloidiasis.
Mota-Ferreira, Daniela M L; Gonçalves-Pires, Maria do Rosário F; Júnior, Alvaro Ferreira; Sopelete, Mônica C; Abdallah, Vânia O S; Costa-Cruz, Julia M
2009-02-01
Strongyloidiasis, caused by the nematode Strongyloides stercoralis, is one of the major worldwide parasitic infections in humans. Breastfeeding may offer a potential protection against this infection. Feces, serum and milk samples were obtained from 90 lactating women from Clinical Hospital of Universidade Federal de Uberlândia, Brazil. The fecal samples were collected for parasitological diagnosis and the serum and milk samples were examined for specific S. stercoralis IgA and IgG antibodies using the indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assay (ELISA). Fecal examination showed that the rate of prevalence of S. stercoralis infection in the lactating women was 4.4%. IFAT manifested a 16.7% positivity rate for specific IgA antibody in serum and a 28.9% rate in milk samples; specific IgG was 41.1% in serum and 25.5% in milk samples. According to ELISA the positivity rate for specific IgA antibody was 21.1% in serum and 42.2% in milk samples; specific IgG was 40% in serum and 18.9% in milk samples. In serum samples, these immunological tests showed a concurrence of 91.1% and 94.4%, respectively, in detecting specific IgA and IgG antibodies. In milk samples, they showed a concurrence of 70% and 78.9%, respectively, in detecting specific IgA and IgG antibodies. There was a statistically significant difference between concordant and discordant results of immunological tests (P<0.0001). IFAT and ELISA highly concurred in their detection of specific S. stercoralis IgA and IgG antibodies in serum and in milk samples reconfirming prior studies that the serological method is a complement to the direct diagnosis of the parasite, and suggesting that immunological methods using milk samples can also be helpful. Furthermore, in endemic areas, infants may acquire antibodies to S. stercoralis from breast milk, possibly, contributing to the enhancement of specific mucosal immunity against this parasite.
High VEGF-D and Low MMP-2 Serum Levels Predict Nodal-Positive Disease in Invasive Bladder Cancer
Benoit, Tobias; Keller, Etienne X.; Wolfsgruber, Pirmin; Hermanns, Thomas; Günthart, Michele; Banzola, Irina; Sulser, Tullio; Provenzano, Maurizio; Poyet, Cédric
2015-01-01
Background To investigate stromal variables including angiogenesis, lymphangiogenesis, and matrix metalloproteinase (MMP) in the serum of patients with urothelial carcinoma of the bladder (UCB) and to evaluate their association with histopathological characteristics and clinical outcome. Material/Methods Protein levels of vascular endothelial growth factors-A, -C, -D (VEGF-A/-C/-D), their receptors- VEGF-R2 and -R3 (VEGF-R2/-R3), and matrix metalloproteinases 2, -3, and -7 (MMP-2, MMP-3, MMP-7) were quantified in the blood serum samples of 71 patients with UCB before radical cystectomy (RC). Samples of patients with non-invasive UCB or no history of UCB were investigated as controls (n=20). Protein levels in the serum were measured using a flow cytometric cytokine assay. Results A positive association for VEGF-D (p<0.001) and an inverse association for MMP-2 (p=0.017) were observed in patients with positive lymph node (LN) status at the time of RC. VEGF-A (p<0.001), VEGF-C (p<0.001), MMP-2 (p<0.001), and MMP-7 (p=0.005) serum levels were different in serum of patients with invasive UCB compared with non-invasive UCB or healthy individuals. None of the serum markers were associated with disease progression. Conclusions High VEGF-D and low MMP-2 serum levels predict LN metastasis in patients with UCB at the time of RC. VEGF-A, VEGF-C, MMP-2, and MMP-7 serum levels varied significantly between invasive and non-invasive disease as well as in comparison with healthy individuals. Clinical implementation of these marker serum measurements may be valuable to select high-risk patients with more invasive or nodal-positive disease. PMID:26241709
Lerch, Oliver; Temme, Oliver; Daldrup, Thomas
2014-07-01
The analysis of opioids, cocaine, and metabolites from blood serum is a routine task in forensic laboratories. Commonly, the employed methods include many manual or partly automated steps like protein precipitation, dilution, solid phase extraction, evaporation, and derivatization preceding a gas chromatography (GC)/mass spectrometry (MS) or liquid chromatography (LC)/MS analysis. In this study, a comprehensively automated method was developed from a validated, partly automated routine method. This was possible by replicating method parameters on the automated system. Only marginal optimization of parameters was necessary. The automation relying on an x-y-z robot after manual protein precipitation includes the solid phase extraction, evaporation of the eluate, derivatization (silylation with N-methyl-N-trimethylsilyltrifluoroacetamide, MSTFA), and injection into a GC/MS. A quantitative analysis of almost 170 authentic serum samples and more than 50 authentic samples of other matrices like urine, different tissues, and heart blood on cocaine, benzoylecgonine, methadone, morphine, codeine, 6-monoacetylmorphine, dihydrocodeine, and 7-aminoflunitrazepam was conducted with both methods proving that the analytical results are equivalent even near the limits of quantification (low ng/ml range). To our best knowledge, this application is the first one reported in the literature employing this sample preparation system.
Serum TIMP1 and TIMP2 concentration in patients with different grades of meningioma.
Mashayekhi, Farhad; Saberi, Alia; Mashayekhi, Sohail
2018-07-01
Meningiomas are common primary brain tumors that constitute about 13% of all intracranial tumors. Matrix metalloproteinase-9 (MMP-9) is able to degrade the extracellular matrix and basement membrane leading to cancer cell invasion and metastasis. MMPs are specifically inhibited by a family of small extracellular proteins known as the tissue inhibitors of metalloproteinases (TIMPs). The objective of this project was to evaluate serum concentration of TIMP-1 and TIMP-2 in patients with different grades of meningioma. Ninety samples from different stages of patients with meningitis (42 cases of grade I, 28 grade II, 20 grade III) and 51 samples from normal healthy were included in this study. Total protein concentration (TPC) and the level TIMP-1 and TIMP-2 serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay (ELISA), respectively. No significant change in the TPC was seen in the serum of patients with meningioma when compared with normal controls. Results obtained demonstrated that all serum samples presented TIMP-1 and TIMP-2 expression, whereas, starting from grade I to III meningiomas, a significant decrease of TIMP-1 and TIMP-2 expression was observed as compared to controls. The results of this study show that a low expression of TIMP1 and TIMP2 is correlated with advanced stages of meningioma. It is also concluded that the detection of serum TIMP1 and TIMP2 may be useful in classifying different grades of meningioma. Copyright © 2018 Elsevier B.V. All rights reserved.
Multiplex Immunoassay Profiling of Serum in Psychiatric Disorders.
Stephen, Laurie; Schwarz, Emanuel; Guest, Paul C
2017-01-01
Multiplex immunoassays allow for the rapid profiling of biomarker proteins in biological fluids, using less sample and labour than in single immunoassays. This chapter details the methods to develop and manufacture a 5-plex immunoassay for the Luminex® platform. Although assay development is not included here, the same methods can be used to covalently couple antibodies to the Luminex beads and to label antibodies for the screening of sandwich pairs, if needed. An example will be given for the analysis of five hormones (glucagon-like peptide 1, growth hormone, insulin, leptin and thyroid-stimulating hormone) in serum samples from schizophrenia patients and controls.
Wollanke, B; Gerhards, H; Brem, S; Kopp, H; Meyer, P
1998-04-01
Between February 1993 and July 1997, 150 horses suffering from recurrent uveitis were subjected to parsplana vitrectomy. In these horses, antibody titers to Leptospira serovars were determined in serum samples and in samples from diluted vitreous collected during vitrectomy. Although the vitreous samples were diluted with 250 ml of balanced salt solution, in 86 of the 150 vitreous samples (= 57%) the antibody titers were higher than in the serum samples. Additionally, serum samples from 77 horses suffering from ERU, but which were not subjected to vitrectomy, and serum samples from 97 horses with clinically normal eyes were analyzed for antibodies to Leptospira serovars. Among the 227 horses with ERU (150 treated surgically, 77 treated conservatively) 50 horses (50 of 227 = 22%) had serum antibody titers to Leptospira serovars of > or = 1:800. Among the 97 horses with clinically normal eyes, 24 horses (24 of 97 = 25%) had serum antibody titers to Leptospira serovars of > or = 1:800. In undiluted vitreous samples from 20 horses with clinically normal eyes, no antibody titers to Leptospira serovars could be detected. Among the 150 horses with ERU, 90 animals (90 of 150 = 60%) had antibody titers of > or = 1:100 in the diluted vitreous samples, the difference being highly significant (p < 0.001). The findings are discussed in relation to the etiology of recurrent uveitis in horses.
Guthmann, Jean-Paul; Klovstad, Hilde; Boccia, Delia; Hamid, Nuha; Pinoges, Loretxu; Nizou, Jacques-Yves; Tatay, Mercedes; Diaz, Francisco; Moren, Alain; Grais, Rebecca Freeman; Ciglenecki, Iza; Nicand, Elisabeth; Guerin, Philippe Jean
2006-06-15
The conflict in Darfur, Sudan, was responsible for the displacement of 1.8 million civilians. We investigated a large outbreak of hepatitis E virus (HEV) infection in Mornay camp (78,800 inhabitants) in western Darfur. To describe the outbreak, we used clinical and demographic information from cases recorded at the camp between 26 July and 31 December 2004. We conducted a case-cohort study and a retrospective cohort study to identify risk factors for clinical and asymptomatic hepatitis E, respectively. We collected stool and serum samples from animals and performed a bacteriological analysis of water samples. Human samples were tested for immunoglobulin G and immunoglobulin M antibody to HEV (for serum samples) and for amplification of the HEV genome (for serum and stool samples). In 6 months, 2621 hepatitis E cases were recorded (attack rate, 3.3%), with a case-fatality rate of 1.7% (45 deaths, 19 of which involved were pregnant women). Risk factors for clinical HEV infection included age of 15-45 years (odds ratio, 2.13; 95% confidence interval, 1.02-4.46) and drinking chlorinated surface water (odds ratio, 2.49; 95% confidence interval, 1.22-5.08). Both factors were also suggestive of increased risk for asymptomatic HEV infection, although this was not found to be statistically significant. HEV RNA was positively identified in serum samples obtained from 2 donkeys. No bacteria were identified from any sample of chlorinated water tested. Current recommendations to ensure a safe water supply may have been insufficient to inactivate HEV and control this epidemic. This research highlights the need to evaluate current water treatment methods and to identify alternative solutions adapted to complex emergencies.
Smol, Ewa; Kłapcińska, Barbara; Kempa, Katarzyna; Fredyk, Artur; Małecki, Andrzej
2015-01-01
Evidence of the role of ANGPTL3, a liver-secreted glycoprotein, in serum lipid turnover, led us to hypothesize that this protein may be involved in modification of the lipid profile induced by exercise-training. Given the lack of data regarding this issue, the main goal of the present study was to investigate the effects of regular participation in a recreational physical activity program on serum ANGPTL3 and selected lipid profile measures in young, apparently healthy female and male adults. We compared serum ANGPTL3, lipid profile measures, common lipid ratios, the Atherogenic Index of Plasma (AIP) and glucose in fasting blood samples derived from 22 active physical education students including active females (AF, N=6) and males (AM, N=16) with samples from 28 relatively sedentary age-matched peers, including female (SF, N=9) and male (SM, N=19) individuals not involved in any regular physical conditioning program. Despite high inter-individual variability of serum ANGPTL3, there was a general tendency toward higher serum ANGPTL3 and HDL-C in women compared to men, but without significant differences related to their physical activity status. Based on both routine lipid profile measures and lipid ratios, all participants had normal lipid profiles, normal glycemia, as well as favorable anthropometric indices not suggesting increased cardiometabolic risk. However, lower levels of the TG/HDL-C ratio and AIP in physically active compared to relatively sedentary participants, reflecting the predominance of large, buoyant LDL particles, strongly support the view of beneficial health-promoting effects of regular participation in recreational sport activities. PMID:26839611
2004-01-01
Abstract A study was performed to evaluate the presence of porcine reproductive and respiratory syndrome virus (PRRSV) in pig meat collected at slaughterhouses and its potential transmission to pigs via pig meat. A total of 1039 blood samples were collected from pigs upon their arrival at the abattoir. The following day, meat samples (n = 1027) were collected from the carcasses of these same pigs. Samples originated from 2 Canadian slaughterhouses, 1 situated in the province of Quebec and the other situated in the province of Manitoba. Serum samples were tested for antibodies to PRRSV and both serum and meat samples were also tested for PRRSV nucleic acid by polymerase chain reaction (PCR). Seropositivity to PRRSV for all serum samples was 74.3%. Furthermore 45 (4.3%) of the total serum samples and 19 (1.9%) of the 1027 meat samples were positive for PRRSV by PCR. Sequence analysis of open reading frame (ORF) 5 performed on 15 of the 19 PRRSV strains identified in pig meat indicated that 9 were field strains and 6 were vaccine-like (98% to 99.7% nucleotide homology with the Ingelvac RespPRRS/Repro vaccine). One of these 6 strains presented an intermediate 2-6-2 restriction fragment length polymorphism (RFLP) cut pattern and the others showed the characteristic 2-5-2 RFLP pattern of the vaccine strain. All strains sequenced were determined to be North American strains. In only 1 of the 19 PRRSV-positive meat samples could PRRSV be isolated. To test the potential infectivity of meat samples containing residual PRRSV, 11 of the PCR-positive meat samples (weighing 1.05 to 1.8 kg) were each used in feeding experiments of 2 PRRSV antibody-negative specific pathogen-free pigs of 9 wk of age. Samples were cut into several pieces and fed to each pair of pigs on 2 consecutive days. Each pig pair was housed in a separate cubicle and serum samples were collected at –7, 0, 7, 14, and 20 to 21 days post exposure. Seven pig pairs were found to be infected by PRRSV following ingestion of meat samples, including meat samples containing vaccine-like virus, as judged by the demonstration of PRRSV antibodies and/or PRRSV nucleic acid in the serum. In summary, the present study indicated that low residual quantities of PRRSV may be found in a small percentage of pig meat collected at slaugtherhouses. Furthermore, when this meat was fed raw to pigs in the experimental setting designed, pigs could be infected by PRRSV. PMID:15581220
Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad
2015-01-01
In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.
Yılmaz, Cansu; Köksal, Nilgün; Özkan, Hilal; Dorum, Bayram Ali; Bağcı, Onur
2017-01-01
Yılmaz C, Köksal N, Özkan H, Dorum BA, Bağcı O. Low serum IGF-1 and increased cytokine levels in tracheal aspirate samples are associated with bronchopulmonary dysplasia. Turk J Pediatr 2017; 59: 122-129. Despite developments in the perinatal and neonatal care, bronchopulmonary dysplasia (BPD) is still the most frequently seen long-term complication in preterm infants. The aim of this prospective study is to investigate the association between the development of BPD and serial measurements of IGF-1 levels and their relationship with levels of IGF-1 and cytokine in tracheal aspirate fluids. A total of 40 premature infants, born at a gestational age of ≤ 32 weeks, were enrolled in the study. On postnatal day-1, 3, 7, 21 and 28 serum IGF-1 levels and IGF-1 levels, IL-6, IL-8, IL-10 and TNF-alpha levels in tracheal aspirate fluid samples of intubated cases were examined. Mean gestational age of 40 patients included in the study was 29.41 ± 2.23 weeks, and their mean birth weight was 1,256.85 ± 311.48 g. BPD was detected in 35% of cases. Mean gestational week and birth weight of the cases that developed BPD were 30 ± 3 weeks and 1,150 ± 295 g, respectively. Serum IGF-1 levels on postnatal day-1, 3, 7, 21 and 28 in cases who developed BPD were significantly lower when compared with those without BPD (p < 0.01). Levels of IL-6, IL-8, IL-10, and TNF-alpha in tracheal aspirate samples were significantly higher in cases with BPD compared to those without BPD (p < 0.05). IGF-1 levels in tracheal aspirate fluid samples did not differ significantly based on the presence of BPD (p > 0.05). Severity of BPD was associated with decreased serum IGF-1 levels and increased cytokine levels in tracheal aspirate samples.
Baillargeon, Paul; Arango-Sabogal, Juan C; Wellemans, Vincent; Fecteau, Gilles
2017-04-01
The objective of this study was to determine if precolostral blood samples are useful to detect apparent fetal infections with bovine viral diarrhea (BVD) and infectious bovine rhinotracheitis (IBR) viruses. A convenience sample of 317 sera from 50 Canadian herds was used in the study. Antibody level was measured using 2 commercial IBR and BVD ELISA kits. Precolostral status of sera was confirmed on 304 samples using serum gamma-glutamyl transferase activity. Postcolostral serum samples yielded a higher proportion of positive results to IBR (OR = 86; 95% CI: 17.8 to 415.7) and BVD (OR = 199.3; 95% CI: 41.7 to 952.3) than did precolostral samples. All positive precolostral serum samples ( n = 7 of 304) originated from calves born to vaccinated cows. Postcolostral positive serum samples ( n = 11 of 13) originated mostly (60%) from calves born to non-vaccinated cows. Precolostral serum sampling can detect apparent fetal infections in a herd.
Cross-reactive antibodies against GM2 and CMV-infected fibroblasts in Guillain-Barré syndrome.
Ang, C W; Jacobs, B C; Brandenburg, A H; Laman, J D; van der Meché, F G; Osterhaus, A D; van Doorn, P A
2000-04-11
To investigate whether anti-GM2 antibodies in patients with Guillain-Barré syndrome (GBS) are induced by molecular mimicry with cytomegalovirus (CMV). Antibodies against ganglioside GM2 are frequently present in the serum from GBS patients with an antecedent infection with CMV. The authors detected inhibition of anti-GM2 reactivity after incubation of GM2-reactive serum samples with fibroblasts infected with a GBS-associated CMV strain. Control sera consisted of GQ1b-reactive samples, and control antigens included uninfected fibroblasts and fibroblasts that were infected with other herpes viruses. Serum immunoglobulin M reactivity with GM2 was decreased in a dose-dependent manner after incubation with CMV-infected fibroblasts. Incubation of anti-GM2-positive serum samples with uninfected fibroblasts and fibroblasts infected with varicella zoster virus did not inhibit anti-GM2 reactivity, whereas this reactivity was slightly decreased after incubation with herpes simplex virus type 1 in one patient. Antibodies against ganglioside GQ1b did not react with CMV-infected fibroblasts. CMV-infected fibroblasts express gangliosidelike epitopes that recognize specifically anti-GM2 antibodies. These results support the hypothesis that antiganglioside antibodies in CMV-infected GBS patients are induced by molecular mimicry between GM2 and antigens that are induced by a CMV infection.
Han, Tiesuo; Zhao, Kui; Wu, Chenchen; Lu, Huijun; Song, Deguang; He, Wenqi; Gao, Feng
2013-02-01
To determine the relationship between viral kinetics and the expression patterns for different cytokines and chemokines in the serum and organs of coxsackievirus B3 (SSM-CVB3)-infected macaques over the course of infection. SSM-CVB3 levels in serum and organs were measured using the Spearman-Karber 50% tissue culture infectious dose (TCID(50)) method. Cytokine and chemokine levels in the serum and organs were measured by indirect-ELISA. Low viral titers were detected in the serum samples on the first day post-inoculation (p.i.) and peaked at 6 to 10 days p.i. in the serum samples from five macaques. Serum levels of IL-1β, IL-2, IL-6, IL-12p40, IL-17α, IFN-γ, TNF-α, MCP-1 and MIP-1β were detected each day and, similar to the viral titers, peaked at 6 to 10 days. IL-10 was only detected on days 10 to 14 p.i. Additionally, higher viral titers and relative viral mRNA levels were associated with higher cytokine and chemokine levels in selected tissues from infected macaques including heart, liver, spleen, lung, kidney and brain. The results indicate that patterns of cytokine and chemokine response are associated with viral kinetics in the serum and target organs of SSM-CVB3-infected macaques, suggesting that the changes in cytokines and chemokines could help further our understanding of the progress of CVB3 infections in clinical settings. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Shaoxin; Zhang, Yanjiao; Xu, Junfa; Li, Linfang; Zeng, Qiuyao; Lin, Lin; Guo, Zhouyi; Liu, Zhiming; Xiong, Honglian; Liu, Songhao
2014-09-01
This study aims to present a noninvasive prostate cancer screening methods using serum surface-enhanced Raman scattering (SERS) and support vector machine (SVM) techniques through peripheral blood sample. SERS measurements are performed using serum samples from 93 prostate cancer patients and 68 healthy volunteers by silver nanoparticles. Three types of kernel functions including linear, polynomial, and Gaussian radial basis function (RBF) are employed to build SVM diagnostic models for classifying measured SERS spectra. For comparably evaluating the performance of SVM classification models, the standard multivariate statistic analysis method of principal component analysis (PCA) is also applied to classify the same datasets. The study results show that for the RBF kernel SVM diagnostic model, the diagnostic accuracy of 98.1% is acquired, which is superior to the results of 91.3% obtained from PCA methods. The receiver operating characteristic curve of diagnostic models further confirm above research results. This study demonstrates that label-free serum SERS analysis technique combined with SVM diagnostic algorithm has great potential for noninvasive prostate cancer screening.
Bowen, Richard A.; O'Shea, Thomas J.; Shankar, Vidya; Neubaum, Melissa A.; Neubaum, Daniel J.; Rupprecht, Charles E.
2013-01-01
We determined the presence of rabies-virus-neutralizing antibodies (RVNA) in serum of 721 insectivorous bats of seven species captured, sampled, and released in Colorado and New Mexico, United States in 2003-2005. A subsample of 160 bats was tested for rabies-virus RNA in saliva. We sampled little brown bats (Myotis lucifugus) at two maternity roosts in Larimer County, Colorado; big brown bats (Eptesicus fuscus) at three maternity roosts in Morgan County, Colorado; and big brown bats at five maternity roosts in Larimer County. We also sampled hoary bats (Lasiurus cinereus) and silver-haired bats (Lasionycteris noctivagans) captured while drinking or foraging over water in Bernalillo County, New Mexico and at various locations in Larimer County. Big brown bats, little brown bats, long-legged myotis (Myotis volans), long-eared myotis (Myotis evotis), and fringed myotis (Myotis thysanodes) were also sampled over water in Larimer County. All species except long-eared myotis included individuals with RVNA, with prevalences ranging from 7% in adult female silver-haired bats to 32% in adult female hoary bats. None of the bats had detectable rabies-virus RNA in oropharyngeal swabs, including 51 bats of 5 species that had RVNA in serum. Antibody-positive bats were present in nine of the 10 maternity colonies sampled. These data suggest that wild bats are commonly exposed to rabies virus and develop a humoral immune response suggesting some degree of viral replication, but many infections fail to progress to clinical disease.
Reed, S M; Howe, D K; Morrow, J K; Graves, A; Yeargan, M R; Johnson, A L; MacKay, R J; Furr, M; Saville, W J A; Williams, N M
2013-01-01
Recent work demonstrated the value of antigen-specific antibody indices (AI and C-value) to detect intrathecal antibody production against Sarcocystis neurona for antemortem diagnosis of equine protozoal myeloencephalitis (EPM). The study was conducted to assess whether the antigen-specific antibody indices can be reduced to a simple serum : cerebrospinal fluid (CSF) titer ratio to achieve accurate EPM diagnosis. Paired serum and CSF samples from 128 horses diagnosed by postmortem examination. The sample set included 44 EPM cases, 35 cervical-vertebral malformation (CVM) cases, 39 neurologic cases other than EPM or CVM, and 10 non-neurologic cases. Antibodies against S. neurona were measured in serum and CSF pairs using the SnSAG2 and SnSAG4/3 (SnSAG2, 4/3) ELISAs, and the ratio of each respective serum titer to CSF titer was determined. Likelihood ratios and diagnostic sensitivity and specificity were calculated based on serum titers, CSF titers, and serum : CSF titer ratios. Excellent diagnostic sensitivity and specificity was obtained from the SnSAG2, 4/3 serum : CSF titer ratio. Sensitivity and specificity of 93.2 and 81.1%, respectively, were achieved using a ratio cutoff of ≤100, whereas sensitivity and specificity were 86.4 and 95.9%, respectively, if a more rigorous cutoff of ≤50 was used. Antibody titers in CSF also provided good diagnostic accuracy. Serum antibody titers alone yielded much lower sensitivity and specificity. The study confirms the value of detecting intrathecal antibody production for antemortem diagnosis of EPM, and they further show that the antigen-specific antibody indices can be reduced in practice to a simple serum : CSF titer ratio. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Marques, Sara S.; Magalhães, Luís M.; Tóth, Ildikó V.; Segundo, Marcela A.
2014-01-01
Total antioxidant capacity assays are recognized as instrumental to establish antioxidant status of biological samples, however the varying experimental conditions result in conclusions that may not be transposable to other settings. After selection of the complexing agent, reagent addition order, buffer type and concentration, copper reducing assays were adapted to a high-throughput scheme and validated using model biological antioxidant compounds of ascorbic acid, Trolox (a soluble analogue of vitamin E), uric acid and glutathione. A critical comparison was made based on real samples including NIST-909c human serum certified sample, and five study samples. The validated method provided linear range up to 100 µM Trolox, (limit of detection 2.3 µM; limit of quantification 7.7 µM) with recovery results above 85% and precision <5%. The validated developed method with an increased sensitivity is a sound choice for assessment of TAC in serum samples. PMID:24968275
Drug residues in serum of dogs receiving anticancer chemotherapy.
Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D
2010-01-01
The presence of drug residues in blood samples can represent an occupational hazard. However, studies on cytotoxic drug residues in serum of dogs are lacking in veterinary oncology. To evaluate possible occupational hazards associated with handling of blood samples from dogs receiving oncolytic drugs 7 days after treatment. Twenty-seven client-owned dogs treated for lymphoma or mast cell tumors with vincristine, vinblastine, cyclophosphamide, or doxorubicin. Prospective, observational study. Serum samples were either taken 7 days after administration of vincristine, cyclophosphamide, doxorubicin (lymphoma), and vinblastine (mast cell tumor), or 1-2 days after the last concurrent oral administration of cyclophosphamide (mast cell tumor). Additionally, serum was collected within 5 minutes of treatment. Measurement of drug residues in serum was performed by liquid chromatography tandem mass spectrometry (LC/MS/MS). In 33 samples collected within 5 minute of treatment, the median serum concentrations were vincristine: 37 microg/L (range: 11-87 microg/L), vinblastine: 13 microg/L (range: 13-35 microg/L), cyclophosphamide: 2,484 microg/L (range: 1,209-2,778 microg/L), doxorubicin: 404 microg/L (range: 234-528 microg/L). In 81 serum samples collected 7 days after treatment vinblastine (7 microg/L) was detected in 1 sample, and cyclophosphamide (7 and 9 microg/L) in 2 samples collected 1-2 days after oral administration of cyclophosphamide. Medications were not detected in any of the other samples. Handling of blood samples from dogs receiving oncolytic chemotherapy 7 days after treatment with vincristine, vinblastine, cyclophosphamide, and doxorubicin should not present a health hazard.
Walsh, Robert B.; Kelton, David F.; Hietala, Sharon K.; Duffield, Todd F.
2013-01-01
Serum and milk samples from 1229 cows on 22 Ontario dairy farms were individually tested for antibodies specific for bovine leukosis virus (BLV) and Neospora caninum by enzyme-linked immunosorbent assay (ELISA). Antibodies against BLV were present in 361 serum samples (29.4%) and 369 milk samples (30.0%). Comparing the 2 tests, agreement was almost perfect (k = 0.86; 95% CI = 0.83 to 0.90) and the proportions of samples positive were not significantly different (P = 0.56). Both tests identified the same 3 herds free of bovine leukosis virus. Antibodies against N. caninum were detected in 138 serum samples (11.2%), and 111 milk samples (9.0%). Agreement between the 2 tests was moderate (k = 0.52; 95% CI = 0.43 to 0.59). Four herds were free of neosporosis by the serum test, while 10 herds were negative by the milk test. The ELISA on milk samples facilitates sample collection to classify herds free of BLV; the milk N. caninum ELISA was less reliable in predicting herd-level infection. PMID:24082160
Estrogen levels in serum and urine of vegetarian and omnivore premenopausal women
Harmon, Brook; Morimoto, Yukiko; Beckford, Fanchon; Franke, Adrian A.; Stanczyk, Frank Z.; Maskarinec, Gertraud
2014-01-01
Objective Based on the hypothesis that high-meat diets may increase breast cancer risk through hormonal pathways, this analysis compared estrogens in serum and urine by meat-eating status. Design Intervention with repeated measures. Setting Two randomized soy trials (BEAN1 and BEAN2) among premenopausal healthy women. Subjects BEAN1 participants completed 7 unannounced 24-hour dietary recalls and donated 5 blood and urine samples over 2 years. BEAN2 women provided 7 recalls and 3 samples over 13 months. Serum samples were analyzed for estrone (E1) and estradiol (E2) using radioimmunoassays. Nine estrogen metabolites were measured in urine by liquid chromatography mass spectrometry. Semi-vegetarians included women who reported <30 g/day of red meat, poultry, and fish and pescatarians who consumed <20 g/day of meat/poultry but >10 g/day of fish. All other women were classified as non-vegetarians. We applied mixed models to compute least-square means by vegetarian status adjusted for potential confounders. Results The mean age of the 272 participants was 41.9±4.5 years. Serum E1 (85 vs 100 pg/mL, p=0.04) and E2 (140 vs 154 pg/mL, p=0.04) levels were lower in the 37 semi-vegetarians than in the 235 non-vegetarians. The sum of the 9 urinary estrogen metabolites (183 vs 200 pmol/mg creatinine, p=0.27) and the proportions of individual estrogens and pathways did not differ by meat-eating status. Restricting the models to the samples collected during the luteal phase strengthened the associations. Conclusions Given the limitations of this study, the lower levels of serum estrogens in semi-vegetarians than non-vegetarians need confirmation in larger populations. PMID:24050121
Zhu, Xiao-Dong; Su, Fang; Liang, Zhong-Guo; Li, Ling; Qu, Song; Liang, Xia; Wang, Qi; Liang, Shi-Xiong; Chen, Long
2014-08-01
As diagnosis of nasopharyngeal carcinoma at an early disease stage is important, we attempted to distinguish between patients with nasopharyngeal carcinoma and noncancer controls by using serum protein profiles. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry and CM10 protein chip were used to detect the serum proteomic patterns of 65 patients with nasopharyngeal carcinoma before radiotherapy and 93 noncancer controls. Proteomic spectra of serum samples from 50 nasopharyngeal carcinoma patients and 60 noncancer controls were used as a training set. The validity of the classification tree was then challenged with a blind test set which included another 15 patients with nasopharyngeal carcinoma and 33 noncancer controls. Biomarker Wizard 3.01 and Biomarker Pattern 5.01 were used in combination to analyze the data and to develop diagnostic models. 21 protein peaks were significantly different between nasopharyngeal carcinoma and controls. 4 mass peaks (M4182, M5343, M5913 and M8702 mass/charge ratio) were chosen automatically to construct a classification tree. The classification tree correctly determined 93.8 % (45/48) of the test samples with 93.3 % (14/15) of the nasopharyngeal carcinoma samples and 93.9 % (31/33) of the noncancer samples. Using a combination of serum protein profiles and Epstein-Barr viral capsid antigen immunoglobulin A antibody tests, the diagnostic sensitivity and specificity were increased to 100 and 97 %, respectively. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry could correctly distinguish nasopharyngeal carcinoma from noncancer individuals and showed great potential for the development of a screening test for the detection of nasopharyngeal carcinoma.
Comparison of serum and plasma measurements of Müllerian inhibiting substance.
Merhi, Zaher O; Messerlian, Geralyn M; Minkoff, Howard; Eklund, Elizabeth E; Macura, Jerzy; Feldman, Joseph; Rodriguez, Carlos; Seifer, David B
2008-06-01
The authors sought to determine whether measurement of plasma Müllerian inhibiting substance (MIS) is a suitable substitute for measurement of serum MIS. Eighteen samples of serum and plasma were examined that were drawn simultaneously. Levels of MIS were measured with an ELISA kit, and plasma levels were studied in parallel to serum samples. A 98.5% correlation was found between serum and plasma MIS values.
Depciuch, J; Parlinska-Wojtan, M
2018-02-20
Depression is a serious mental illness. To study the mechanism of depression and search for new, more effective therapies, animal models are often used. Unfortunately, none of the available models reflects all the symptoms of depression. Therefore researchers are looking for new tools to diagnose depression. Unfortunately, the nowadays-available depression diagnosis methods are only psychological tests. However, it is known, that the amount of phospholipids, proteins and lipids decreases during depression. Raman and FTIR (Fourier Transform Infra Red) spectroscopies provide information on the chemical compounds in the measured sample e.g. blood serum. These spectroscopic techniques may thus become reliable and accurate tools for evaluating changes in the amount of phospholipids and proteins in depression disease. In this study differences between dried and liquid blood serum samples of healthy and depressed individuals measured by Raman (range 0-3000cm -1 ) and FTIR (Fourier Transform Infrared) (range 900-3000cm -1 ) spectroscopy were evaluated. The resulting spectra and accurate analysis led to the conclusion that an appropriate measurement of the background and the elimination of peaks from water had the greatest impact on the reliability of the results. Furthermore, after detailed studies of FTIR and Raman spectra of dried and liquid blood serum samples, including a complete analysis of peaks after Kramers-Kröning (KK) transformation, it was found that the sample preparation did not affect the results obtained by Raman spectroscopy. In FTIR measurements only a minimal effect on peak intensity was observed. Copyright © 2017 Elsevier B.V. All rights reserved.
Optimal combinations of acute phase proteins for detecting infectious disease in pigs.
Heegaard, Peter M H; Stockmarr, Anders; Piñeiro, Matilde; Carpintero, Rakel; Lampreave, Fermin; Campbell, Fiona M; Eckersall, P David; Toussaint, Mathilda J M; Gruys, Erik; Sorensen, Nanna Skall
2011-03-17
The acute phase protein (APP) response is an early systemic sign of disease, detected as substantial changes in APP serum concentrations and most disease states involving inflammatory reactions give rise to APP responses. To obtain a detailed picture of the general utility of porcine APPs to detect any disease with an inflammatory component seven porcine APPs were analysed in serum sampled at regular intervals in six different experimental challenge groups of pigs, including three bacterial (Actinobacillus pleuropneumoniae, Streptococcus suis, Mycoplasma hyosynoviae), one parasitic (Toxoplasma gondii) and one viral (porcine respiratory and reproductive syndrome virus) infection and one aseptic inflammation. Immunochemical analyses of seven APPs, four positive (C-reactive protein (CRP), haptoglobin (Hp), pig major acute phase protein (pigMAP) and serum amyloid A (SAA)) and three negative (albumin, transthyretin, and apolipoprotein A1 (apoA1)) were performed in the more than 400 serum samples constituting the serum panel. This was followed by advanced statistical treatment of the data using a multi-step procedure which included defining cut-off values and calculating detection probabilities for single APPs and for APP combinations. Combinations of APPs allowed the detection of disease more sensitively than any individual APP and the best three-protein combinations were CRP, apoA1, pigMAP and CRP, apoA1, Hp, respectively, closely followed by the two-protein combinations CRP, pigMAP and apoA1, pigMAP, respectively. For the practical use of such combinations, methodology is described for establishing individual APP threshold values, above which, for any APP in the combination, ongoing infection/inflammation is indicated.
Association between serum antibodies to periodontal bacteria and rheumatoid factor in NHANES III
Goh, Charlene E.; Kopp, Jacob; Papapanou, Panos N.; Molitor, Jerry A.; Demmer, Ryan T.
2016-01-01
Objective Alterations in the microbiome, including the periodontal microbiome, may be a risk factor for rheumatoid arthritis (RA). Most studies that have analyzed this association are relatively small, focus primarily on a single periodontal pathogen (Porphyromonas gingivalis), and are not population-based. We investigated the association between elevated serum IgG antibodies to 19 periodontal species and the prevalence of rheumatoid factor (RF) in a large nationally representative sample of adults. Methods The Third National Health and Nutrition Examination Survey is a cross-sectional sample of the non-institutionalized US population (n=33,994). Our study population included all dentate participants ≥60 years, who did not have RA as defined by a modified version of the American College of Rheumatology 1987 criteria, and had complete data for both serum IgG antibodies against periodontal bacteria and serum RF antibody titer (n=2461). Results Adjusted odds ratios (ORs) (95% CI) summarizing the relationship between the 19 periodontal serum IgGs and RF seropositivity ranged from 0.53 (0.29, 0.97) to 1.27 (0.79, 2.06), and 17 of the 19 observed ORs were < 1.0. The ORs for RF seropositivity among participants with elevated Prevotella intermedia [0.53 (0.29, 0.97)] and Capnocytophaga ochracea [0.54 (0.31, 0.95)] IgG were statistically significant. Conclusion We have found elevated periodontal IgGs to be mostly unassociated with RF seropositivity in the nationally representative NHANES III. Elevated antibody levels to P. intermedia and C. ochracea were associated with lower odds of RF seropositivity. PMID:27110949
Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Sun, Xuefei; Gao, Yuqian
2013-07-05
We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50-100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion and the multiplexing potential of this technique. Limits of quantification (LOQs) at low ng/mL levels with a medianmore » CV of ~12% were achieved for proteins spiked into human female serum using as little as 2 µL serum. PRISM-SRM provided up to ~1000-fold improvement in the LOQ when compared to conventional SRM measurements. Multiplexing capability of PRISM-SRM was also evaluated by two sets of serum samples with 6 and 21 target peptides spiked at the low attomole/µL levels. The results from SRM measurements for pooled or post-concatenated samples were comparable to those obtained from individual peptide fractions in terms of signal-to-noise ratios and SRM peak area ratios of light to heavy peptides. PRISM-SRM was applied to measure several ng/mL-level endogenous plasma proteins, including prostate-specific antigen, in clinical patient sera where correlation coefficients > 0.99 were observed between the results from PRISM-SRM and ELISA assays. Our results demonstrate that PRISM-SRM can be successfully used for quantification of low-abundance endogenous proteins in highly complex samples. Moderate throughput (50 samples/week) can be achieved by applying the post-concatenation or fraction multiplexing strategies. We anticipate broad applications for targeted PRISM-SRM quantification of low-abundance cellular proteins in systems biology studies as well as candidate biomarkers in biofluids.« less
Environmental Chemicals in Urine and Blood: Improving Methods for Creatinine and Lipid Adjustment.
O'Brien, Katie M; Upson, Kristen; Cook, Nancy R; Weinberg, Clarice R
2016-02-01
Investigators measuring exposure biomarkers in urine typically adjust for creatinine to account for dilution-dependent sample variation in urine concentrations. Similarly, it is standard to adjust for serum lipids when measuring lipophilic chemicals in serum. However, there is controversy regarding the best approach, and existing methods may not effectively correct for measurement error. We compared adjustment methods, including novel approaches, using simulated case-control data. Using a directed acyclic graph framework, we defined six causal scenarios for epidemiologic studies of environmental chemicals measured in urine or serum. The scenarios include variables known to influence creatinine (e.g., age and hydration) or serum lipid levels (e.g., body mass index and recent fat intake). Over a range of true effect sizes, we analyzed each scenario using seven adjustment approaches and estimated the corresponding bias and confidence interval coverage across 1,000 simulated studies. For urinary biomarker measurements, our novel method, which incorporates both covariate-adjusted standardization and the inclusion of creatinine as a covariate in the regression model, had low bias and possessed 95% confidence interval coverage of nearly 95% for most simulated scenarios. For serum biomarker measurements, a similar approach involving standardization plus serum lipid level adjustment generally performed well. To control measurement error bias caused by variations in serum lipids or by urinary diluteness, we recommend improved methods for standardizing exposure concentrations across individuals.
Pradeep, A R; Manjunath, R G Shiva; Kathariya, Rahul
2010-11-01
Increased C-reactive protein levels have been found in all active inflammations, including periodontitis. This study aims to assess the C-reactive protein levels in periodontal disease progression. Forty-five patients were divided into the following three groups (n=15) based on gingival index, probing pocket depth, and clinical attachment level: healthy (group I), gingivitis (group II), and chronic periodontitis (group III). Gingival crevicular fluid and serum samples were quantified for C-reactive protein using enzyme-linked immunosorbent assay. The mean C-reactive protein concentration in gingival crevicular fluid and serum was found to be highest in group III (1233.33ng/mL for gingival crevicular fluid, 5483.33ng/mL for serum), and least in group I (60 ng/mL and 413 ng/mL for gingival crevicular fluid and serum, respectively) The mean C-reactive protein concentration in group II (453.33ng/mL for gingival crevicular fluid and 3565.33 ng/mL for serum) was found to be intermediate. C-reactive protein levels in gingival crevicular fluid and serum increased proportionately with the severity of periodontal disease. They correlated positively with clinical parameters, including gingival index, probing pocket depth, and clinical attachment level. Thus, it can be considered as a periodontal inflammatory biomarker and deserves further consideration. © 2010 Blackwell Publishing Asia Pty Ltd.
Samlıoğlu, Pınar; Unalp, Aycan; Gökçay, Ahmet; Altuğlu, Imre; Oztürk, Aysel; Zeytinoğlu, Ayşın
2012-10-01
Subacute sclerosing panencephalitis (SSPE) caused by persistent defective measles virus strains, is a progressive neurological disorder of children and adolescents. The aim of this letter was to share the data from SSPE-suspected cases who were definitely diagnosed by the detection of increased antibody index in serum and cerebrospinal fluid (CSF) samples. A total of 11 patients (mean age: 14.3 years) with suspected SSPE between February 2006 to August 2008, were included in the study. Simultaneously obtained serum and CSF samples from patients were analyzed in terms of albumin, total IgG and measles-specific IgG levels (Measles Virus IgG ELISA for CSF Diagnostics, Euroimmun, Germany). The value of CSQrel (relative CSF/serum quotient) ≥ 1.5 was accepted indicative for intrathecal measles antibody synthesis. Seven (63.6%) of the 11 patients' diagnosis were confirmed with the demonstration of elevated CSF/serum indices (CSQrel range: 2.3-36.9; mean: 12.9). Mean age of those seven cases was 12.3 years (age range: 7-21) and four of them were male. The history of patients with high antibody indices indicated that three of four patients who had measles infection had not been vaccinated against measles. These three unvaccinated patients had measles infection at 3rd, 8th and 30th months of age, respectively, and the period of SSPE development were 15, 6 and 4.5 years, respectively. With this letter we would like to emphasize once more that effective measles vaccination is the only way for the prevention of measles and SSPE and the demonstration of increased measles antibody index in simultaneously obtained serum and CSF samples is crucial for the diagnosis of SSPE.
Centrifugal microfluidic platform for ultrasensitive detection of botulinum toxin
Koh, Chung -Yan; Schaff, Ulrich Y.; Sandstone Diagnostics, Livermore, CA; ...
2014-12-18
In this study, we present an innovative centrifugal microfluidic immunoassay platform (SpinDx) to address the urgent biodefense and public health need for ultrasensitive point-of-care/incident detection of botulinum toxin. The simple, sample-to-answer centrifugal microfluidic immunoassay approach is based on binding of toxins to antibody-laden capture particles followed by sedimentation of the particles through a density-media in a microfluidic disk and quantification by laser-induced fluorescence. A blind, head-to-head comparison study of SpinDx versus the gold-standard mouse bioassay demonstrates 100-fold improvement in sensitivity (limit of detection = 0.09 pg/mL), while achieving total sample-to-answer time of <30 min with 2-μL required volume of themore » unprocessed sample. We further demonstrate quantification of botulinum toxin in both exogeneous (human blood and serum spiked with toxins) and endogeneous (serum from mice intoxicated via oral, intranasal, and intravenous routes) samples. SpinDx can analyze, without any sample preparation, multiple sample types including whole blood, serum, and food. It is readily expandable to additional analytes as the assay reagents (i.e., the capture beads and detection antibodies) are disconnected from the disk architecture and the reader, facilitating rapid development of new assays. SpinDx can also serve as a general-purpose immunoassay platform applicable to diagnosis of other conditions and diseases.« less
Thoresen, Stein I; Arnemo, Jon M; Liberg, Olof
2009-06-01
Scandinavian free-ranging wolves (Canis lupus) are endangered, such that laboratory data to assess their health status is increasingly important. Although wolves have been studied for decades, most biological information comes from captive animals. The objective of the present study was to establish reference intervals for 30 clinical chemical and 8 hematologic analytes in Scandinavian free-ranging wolves. All wolves were tracked and chemically immobilized from a helicopter before examination and blood sampling in the winter of 7 consecutive years (1998-2004). Seventy-nine blood samples were collected from 57 gray wolves, including 24 juveniles (24 samples), 17 adult females (25 samples), and 16 adult males (30 samples). Whole blood and serum samples were stored at refrigeration temperature for 1-3 days before hematologic analyses and for 1-5 days before serum biochemical analyses. Reference intervals were calculated as 95% confidence intervals except for juveniles where the minimum and maximum values were used. Significant differences were observed between adult and juvenile wolves for RBC parameters, alkaline phosphatase and amylase activities, and total protein, albumin, gamma-globulins, cholesterol, creatinine, calcium, chloride, magnesium, phosphate, and sodium concentrations. Compared with published reference values for captive wolves, reference intervals for free-ranging wolves reflected exercise activity associated with capture (higher creatine kinase activity, higher glucose concentration), and differences in nutritional status (higher urea concentration).
Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.
Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto
2017-04-01
Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Oberhauser, Felix; Kornhuber, Johannes; Wiltfang, Jens; Fassbender, Klaus; Schroeter, Matthias L.; Volk, Alexander E.; Diehl-Schmid, Janine; Prudlo, Johannes; Danek, Adrian; Landwehrmeyer, Bernhard; Lauer, Martin; Otto, Markus; Jahn, Holger
2018-01-01
Information on circulating miRNAs in frontotemporal lobar degeneration is very limited and conflicting results have complicated an interpretation in Alzheimer’s disease thus far. In the present study we I) collected samples from multiple clinical centers across Germany, II) defined 3 homogenous patient groups with high sample sizes (bvFTD n = 48, AD n = 48 and cognitively healthy controls n = 44), III) compared expression levels in both CSF and serum samples and IV) detected a limited set of miRNAs by using a MIQE compliant protocol based on SYBR-green miRCURY assays that have proven reliable to generate reproducible results. We included several quality controls that identified and reduced technical variation to increase the reliability of our data. We showed that the expression levels of circulating miRNAs measured in CSF did not correlate with levels in serum. Using cluster analysis we found expression pattern in serum that, in part, reflects the genomic organization and affiliation to a specific miRNA family and that were specifically altered in bvFTD, AD, and control groups. Applying factor analysis we identified a 3-factor model characterized by a miRNA signature that explained 80% of the variance classifying healthy controls with 97%, bvFTD with 77% and AD with 72% accuracy. MANOVA confirmed signals like miR-320a and miR-26b-5p at BH corrected significance that contributed most to discriminate bvFTD cases with 96% sensitivity and 90% specificity and AD cases with 89% sensitivity and specificity compared to healthy controls, respectively. Correlation analysis revealed that miRNAs from the 3-factor model also correlated with levels of protein biomarker amyloid-beta1-42 and phosphorylated neurofilament heavy chain, indicating their potential role in the monitoring of progressive neuronal degeneration. Our data show that miRNAs can be reproducibly measured in serum and CSF without pre-amplification and that serum includes higher expressed signals that demonstrate an overall better ability to classify bvFTD, AD and healthy controls compared to signals detected in CSF. PMID:29746584
Vaidya, Sunil R; Dvivedi, Garima M; Jadhav, Santoshkumar M
2016-01-01
The reports from the countries where mumps vaccine is given as routine immunization suggest differences in mumps virus neutralizing antibody titres when tested with vaccine and wild type viruses. Such reports are unavailable from countries like India where mumps vaccine is not included in routine immunization. We, therefore, undertook this study to understand the cross-neutralization activity of Indian mumps viruses. By using commercial mumps IgG enzyme immunoassay (EIA) and a rapid focus reduction neutralization test (FRNT), a panel of serum samples was tested. The panel consisted of 14 acute and 14 convalescent serum samples collected during a mumps outbreak and 18 archived serum samples. Two wild types (genotypes C and G) and Leningrad-Zagreb vaccine strain (genotype N) were used for the challenge experiments and FRNT titres were determined and further compared. The HN protein sequence of three mumps viruses was analyzed for the presence of key epitopes. All serum samples effectively neutralized mumps virus wild types and a vaccine strain. However, significantly lower FRNT titres were noted to wild types than to vaccine strain (P<0.05). The comparison between EIA and FRNT results revealed 95.6 per cent agreement. No amino acid changes were seen in the epitopes in the Indian wild type strains. All potential N-linked glycosylation sites were observed in Indian strains. Good cross-neutralization activity was observed for three mumps virus strains, however, higher level of FRNT titres was detected for mumps virus vaccine strain compared to Indian wild type isolates.
Effect of Repeated Freezing and Thawing on 18 Clinical Chemistry Analytes in Rat Serum
Kale, Vijay P; Patel, Sweta G; Gunjal, Prashant S; Wakchaure, Santosh U; Sundar, Rajesh S; Ranvir, Ramchandra K; Jain, Mukul R
2012-01-01
In a preclinical research laboratory, using serum samples that have been frozen and thawed repeatedly is sometimes unavoidable when needing to confirm previous results or perform additional analysis. Here we determined the effects of multiple cycles of refrigeration or freezing and thawing of rat serum at 3 temperature conditions for different storage times on clinical chemistry analytes. Serum samples obtained from adult Wistar rats were stored at 2 to 8 °C and −10 to −20 °C for as long as 72 h and at −70 °C for as long as 30 d. At different time points (24, 48, and 72 h for samples stored at 2 to 8 °C or −10 to −20 °C and 1, 7, and 30 d for samples stored at −70 °C), the samples were brought to room temperature, analyzed, and then stored again at the designated temperature. The results obtained after each storage cycle were compared with those obtained from the initial analysis of fresh samples. Of the 18 serum analytes evaluated, 14 were stable without significant changes, even after 3 freeze–thaw cycles at the tested temperature ranges. Results from this study will help researchers working with rat serum to interpret the biochemical data obtained from serum samples that have been frozen and thawed repeatedly. PMID:23043814
Marshall, Nicole E; Fraley, Gwen; Feist, Cori; Burns, Michael J; Pereira, Leonardo
2012-08-01
To determine the prevalence of abnormal karyotype results in women undergoing chorionic villus sampling (CVS) for abnormal first trimester screening compared to CVS for historical indications (advanced maternal age (AMA) or prior aneuploidy). Retrospective cohort of all patients undergoing CVS at Oregon Health & Science University from January 2006 to June 2010. Patients were separated based on CVS indication: (1) positive ultrasound (U/S) or serum screening; or (2) AMA or prior aneuploidy with normal or no screening. Prevalence of abnormal karyotype results were compared between groups. Fetal karyotyping was successful in 500 of 506 CVS procedures performed. 203 CVS were performed for positive screening with 69 abnormal karyotypes (34.0%). 264 CVS were performed for historical indications with 11 abnormal karyotypes (4.2%). This difference was statistically significant (χ(2) 71.9, p < 0.001; OR 11.8 [95% CI 5.8, 24.6]). There were two age-related aneuplodies in AMA women without positive screening. 42 out of 44 AMA women diagnosed with aneuploidy (95.5%) had abnormal U/S and/or serum screening (35 U/S, 4 serum, 3 U/S and serum). Combined ultrasound and serum screening should be recommended to all women, including AMA women, prior to undergoing invasive testing to improve risk-based counseling and minimize morbidity.
NASA Astrophysics Data System (ADS)
Lin, Duo; Feng, Shangyuan; Pan, Jianji; Chen, Yanping; Lin, Juqiang; Sun, Liqing; Chen, Rong
2011-11-01
Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopic technique that is capable of probing the biomolecular changes associated with diseased transformation. The objective of our study was to explore gold nanoparticle based SERS to obtain blood serum biochemical information for non-invasive colorectal cancer detection. SERS measurements were performed on two groups of blood serum samples: one group from patients (n = 38) with pathologically confirmed colorectal cancer and the other group from healthy volunteers (control subjects, n = 45). Tentative assignments of the Raman bands in the measured SERS spectra suggested interesting cancer specific biomolecular changes, including an increase in the relative amounts of nucleic acid, a decrease in the percentage of saccharide and proteins contents in the blood serum of colorectal cancer patients as compared to that of healthy subjects. Principal component analysis (PCA) of the measured SERS spectra separated the spectral features of the two groups into two distinct clusters with little overlaps. Linear discriminate analysis (LDA) based on the PCA generated features differentiated the nasopharyngeal cancer SERS spectra from normal SERS spectra with high sensitivity (97.4%) and specificity (100%). The results from this exploratory study demonstrated that gold nanoparticle based SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of colorectal cancers.
NASA Astrophysics Data System (ADS)
Lin, Duo; Feng, Shangyuan; Pan, Jianji; Chen, Yanping; Lin, Juqiang; Sun, Liqing; Chen, Rong
2012-03-01
Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopic technique that is capable of probing the biomolecular changes associated with diseased transformation. The objective of our study was to explore gold nanoparticle based SERS to obtain blood serum biochemical information for non-invasive colorectal cancer detection. SERS measurements were performed on two groups of blood serum samples: one group from patients (n = 38) with pathologically confirmed colorectal cancer and the other group from healthy volunteers (control subjects, n = 45). Tentative assignments of the Raman bands in the measured SERS spectra suggested interesting cancer specific biomolecular changes, including an increase in the relative amounts of nucleic acid, a decrease in the percentage of saccharide and proteins contents in the blood serum of colorectal cancer patients as compared to that of healthy subjects. Principal component analysis (PCA) of the measured SERS spectra separated the spectral features of the two groups into two distinct clusters with little overlaps. Linear discriminate analysis (LDA) based on the PCA generated features differentiated the nasopharyngeal cancer SERS spectra from normal SERS spectra with high sensitivity (97.4%) and specificity (100%). The results from this exploratory study demonstrated that gold nanoparticle based SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of colorectal cancers.
Measurement of rivaroxaban and apixaban in serum samples of patients
Harenberg, Job; Krämer, Sandra; Du, Shanshan; Zolfaghari, Shabnam; Schulze, Astrid; Krämer, Roland; Weiss, Christel; Wehling, Martin; Lip, Gregory Y H
2014-01-01
Background The determination of rivaroxaban and apixaban from serum samples of patients may be beneficial in specific clinical situations when additional blood sampling for plasma and thus the determination of factor Xa activity is not feasible or results are not plausible. Materials and methods The primary aim of this study was to compare the concentrations of rivaroxaban and apixaban in serum with those measured in plasma. Secondary aims were the performance of three different chromogenic methods and concentrations in patients on treatment with rivaroxaban 10 mg od (n = 124) or 20 mg od (n = 94) or apixaban 5 mg bid (n = 52) measured at different time. Results Concentrations of rivaroxaban and apixaban in serum were about 20–25% higher compared with plasma samples with a high correlation (r = 0·79775–0·94662) using all assays (all P < 0·0001). The intraclass correlation coefficients were about 0·90 for rivaroxaban and 0·55 for apixaban. Mean rivaroxaban concentrations were higher at 2 and 3 h compared with 1 and 12 h after administration measured from plasma and serum samples (all P-values < 0·05) and were not different between 1 vs. 12 h (plasma and serum). Conclusions The results indicate that rivaroxaban and apixaban concentrations can be determined specifically from serum samples. PMID:24931429
Association of Mood Disorders with Serum Zinc Concentrations in Adolescent Female Students.
Tahmasebi, Kobra; Amani, Reza; Nazari, Zahra; Ahmadi, Kambiz; Moazzen, Sara; Mostafavi, Seyed-Ali
2017-08-01
Among various factors influencing mood disorders, the impact of micronutrient deficiencies has attracted a great attention. Zinc deficiency is considered to play a crucial role in the onset and progression of mood disorders in different stages of life. The main objective of this study was to assess the correlation between serum zinc levels and mood disorders in high school female students. This cross-sectional study was conducted on a random sample of 100 representative high school female students. The participants completed 24-h food recall questionnaires to assess the daily zinc intakes. Serum zinc status was assessed using flame atomic absorption spectrometry, and zinc deficiency was defined accordingly. Mood disorders were estimated by calculating the sum of two test scores including Beck's depression inventory (BDI) and hospital anxiety depression scale (HADS) tests. General linear model (GLM) and Pearson's regression test were applied to show the correlation of serum zinc levels and mood disorder scores and the correlation between zinc serum levels and BDI scores, respectively. Dietary zinc intake was higher in subjects with normal zinc concentrations than that of zinc-deficient group (p = 0.001). Serum zinc levels were inversely correlated with BDI and HADS scores (p < 0.05). Each 10 μg/dL increment in serum zinc levels led to 0.3 and 0.01 decrease in depression and anxiety scores, respectively (p < 0.05). Serum zinc levels were inversely correlated with mood disorders including depression and anxiety in adolescent female students. Increasing serum levels of zinc in female students could improve their mood disorders.
Radiation-Induced Changes in Serum Lipidome of Head and Neck Cancer Patients
Jelonek, Karol; Pietrowska, Monika; Ros, Malgorzata; Zagdanski, Adam; Suchwalko, Agnieszka; Polanska, Joanna; Marczyk, Michal; Rutkowski, Tomasz; Skladowski, Krzysztof; Clench, Malcolm R.; Widlak, Piotr
2014-01-01
Cancer radiotherapy (RT) induces response of the whole patient’s body that could be detected at the blood level. We aimed to identify changes induced in serum lipidome during RT and characterize their association with doses and volumes of irradiated tissue. Sixty-six patients treated with conformal RT because of head and neck cancer were enrolled in the study. Blood samples were collected before, during and about one month after the end of RT. Lipid extracts were analyzed using MALDI-oa-ToF mass spectrometry in positive ionization mode. The major changes were observed when pre-treatment and within-treatment samples were compared. Levels of several identified phosphatidylcholines, including (PC34), (PC36) and (PC38) variants, and lysophosphatidylcholines, including (LPC16) and (LPC18) variants, were first significantly decreased and then increased in post-treatment samples. Intensities of changes were correlated with doses of radiation received by patients. Of note, such correlations were more frequent when low-to-medium doses of radiation delivered during conformal RT to large volumes of normal tissues were analyzed. Additionally, some radiation-induced changes in serum lipidome were associated with toxicity of the treatment. Obtained results indicated the involvement of choline-related signaling and potential biological importance of exposure to clinically low/medium doses of radiation in patient’s body response to radiation. PMID:24747595
Vera-Candioti, Luciana; Culzoni, María J; Olivieri, Alejandro C; Goicoechea, Héctor C
2008-11-01
Drug monitoring in serum samples was performed using second-order data generated by CE-DAD, processed with a suitable chemometric strategy. Carbamazepine could be accurately quantitated in the presence of its main metabolite (carbamazepine epoxide), other therapeutic drugs (lamotrigine, phenobarbital, phenytoin, phenylephrine, ibuprofen, acetaminophen, theophylline, caffeine, acetyl salicylic acid), and additional serum endogenous components. The analytical strategy consisted of the following steps: (i) serum sample clean-up to remove matrix interferences, (ii) data pre-processing, in order to reduce the background and to correct for electrophoretic time shifts, and (iii) resolution of fully overlapped CE peaks (corresponding to carbamazepine, its metabolite, lamotrigine and unexpected serum components) by the well-known multivariate curve resolution-alternating least squares algorithm, which extracts quantitative information that can be uniquely ascribed to the analyte of interest. The analyte concentration in serum samples ranged from 2.00 to 8.00 mg/L. Mean recoveries were 102.6% (s=7.7) for binary samples, and 94.8% (s=13.5) for spiked serum samples, while CV (%)=4.0 was computed for five replicate, indicative of the acceptable accuracy and precision of the proposed method.
Serological evidence for the presence of influenza D virus in small ruminants.
Quast, Megan; Sreenivasan, Chithra; Sexton, Gabriel; Nedland, Hunter; Singrey, Aaron; Fawcett, Linda; Miller, Grant; Lauer, Dale; Voss, Shauna; Pollock, Stacy; Cunha, Cristina W; Christopher-Hennings, Jane; Nelson, Eric; Li, Feng
2015-11-18
Influenza D virus (FLUDV) was isolated from diseased pigs with respiratory disease symptoms in 2011, and since then the new virus has also been spread to cattle. Little is known about the susceptibility of other agricultural animals and poultry to FLUDV. This study was designed to determine if other farm animals such as goats, sheep, chickens, and turkey are possible hosts to this newly emerging influenza virus. 648 goat and sheep serum samples and 250 chicken and turkey serum samples were collected from 141 small ruminant and 25 poultry farms from different geographical locations in the United States and Canada. Serum samples were examined using the hemagglutination inhibition (HI) assay and the sheep and goat samples were further analyzed using the serum neutralization assay. Results of this study showed FLUDV antibodies were detected in 13.5% (17/126) of the sampled sheep farms, and 5.2% (29/557) of tested sheep serum samples were positive for FLUDV antibodies. For the goat results, the FLUDV antibodies were detected in 13.3% (2/15) of the sampled farms, and 8.8% (8/91) of the tested goat serum samples were positive for FLUDV antibodies. Furthermore, all tested poultry serum samples were negative for FLUDV antibodies. Our data demonstrated that sheep and goat are susceptible to FLUDV virus and multiple states in U.S. have this virus infection already in these two species. This new finding highlights a need for future surveillance of FLUDV virus in small ruminants toward better understanding both the origin and natural reservoir of this new virus. Copyright © 2015 Elsevier B.V. All rights reserved.
Pietrowska, M; Marczak, L; Polanska, J; Nowicka, E; Behrent, K; Tarnawski, R; Stobiecki, M; Polanski, A; Widlak, P
2010-01-01
Mass spectrometry-based analysis of the serum proteome allows identifying multi-peptide patterns/signatures specific for blood of cancer patients, thus having high potential value for cancer diagnostics. However, because of problems with optimization and standardization of experimental and computational design, none of identified proteome patterns/signatures was approved for diagnostics in clinical practice as yet. Here we compared two methods of serum sample preparation for mass spectrometry-based proteome pattern analysis aimed to identify biomarkers that could be used in early detection of breast cancer patients. Blood samples were collected in a group of 92 patients diagnosed at early (I and II) stages of the disease before the start of therapy, and in a group of age-matched healthy controls (104 women). Serum specimens were purified and analyzed using MALDI-ToF spectrometry, either directly or after membrane filtration (50 kDa cut-off) to remove albumin and other large serum proteins. Mass spectra of the low-molecular-weight fraction (2-10 kDa) of the serum proteome were resolved using the Gaussian mixture decomposition, and identified spectral components were used to build classifiers that differentiated samples from breast cancer patients and healthy persons. Mass spectra of complete serum and membrane-filtered albumin-depleted samples have apparently different structure and peaks specific for both types of samples could be identified. The optimal classifier built for the complete serum specimens consisted of 8 spectral components, and had 81% specificity and 72% sensitivity, while that built for the membrane-filtered samples consisted of 4 components, and had 80% specificity and 81% sensitivity. We concluded that pre-processing of samples to remove albumin might be recommended before MALDI-ToF mass spectrometric analysis of the low-molecular-weight components of human serum Keywords: albumin removal; breast cancer; clinical proteomics; mass spectrometry; pattern analysis; serum proteome.
Molecular diagnosis of Toxoplasma gondii infection in Libya.
Gashout, Aisha; Amro, Ahmad; Erhuma, Mabruk; Al-Dwibe, Hamida; Elmaihub, Eanas; Babba, Hamouda; Nattah, Nabil; Abudher, Abdalhafid
2016-04-16
Toxoplasma gondii infections are prevalent in humans and animals throughout Libya. Current diagnosis is based on detection of Toxoplasma-specific IgM and IgG. In this study, we established and optimized a diagnostic PCR assay for molecular diagnosis of T. gondii in Libya. From January to December, 2010, 177 blood and serum samples were collected from suspected patients. This includes: 140 women who have had spontaneous abortions, 26 HIV-positive patients, nine patients with leukemia and lymphoma, and two infants with ocular infection. Samples were screened for anti-Toxoplasma IgG and IgM antibodies before DNA extraction. The surface antigen gene 2 (SAG2) was targeted in a semi-nested PCR to amplify a 999 bp and a 614 bp fragment in the first and the second run respectively. A total of 54/140 (38.5 %) women who have had spontaneous abortions, 23/26 (88 %) HIV patients, 6/9 (66.6 %) of the leukaemia and lymphoma patients, and one child with ocular infection were seropositive for anti-Toxoplasma IgG and/or IgM. Genomic DNA was extracted from 38 selected seropositive samples. The PCR was sensitive enough to detect DNA concentration of 12 ng/μL. PCR analysis was performed for 38 selected seropositive patients (16 women who have had spontaneous abortions, 15 positive HIV patients, six leukaemia patients and one child with ocular infection). Our designed primers were successfully amplified in 22/38 (57.9 %) samples; 5/12 (35.7 %) from serum and 17/26 (65.8 %) from whole blood samples. All PCR positive samples were IgG-positive except two samples which were IgM and IgG & IgM-positive serum samples respectively. The semi-nested PCR confirmed five more samples. These included two leukaemia and two HIV-positive whole blood samples and one serum sample from an aborted woman. The ability of PCR to diagnose active toxoplasmosis is needed in immunocompromised patients and congenital toxoplasmosis cases, especially when serological techniques fail. For the first time in Libya, we established and optimized semi-nested PCR of SAG2 gene. The developed PCR method was able to detect as little as 12 ng/μL of T. gondii DNA and was useful to diagnose the diseases in women who have had spontaneous abortions, HIV-positive patients, patients with leukemia and lymphoma, and infants with ocular infection.
Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus.
Portilho, M M; Mendonça, Acf; Marques, V A; Nabuco, L C; Villela-Nogueira, C A; Ivantes, Cap; Lewis-Ximenez, L L; Lampe, E; Villar, L M
2017-11-01
This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.
Serum chemistry comparisons between captive and free-ranging giraffes (Giraffa camelopardalis).
Schmidt, Debra A; Barbiers, Robyn B; Ellersieck, Mark R; Ball, Ray L; Koutsos, Elizabeth A; Griffin, Mark E; Grobler, Douw; Citino, Scott B; Bush, Mitchell
2011-03-01
Serum chemistry analyses were compared between captive and free-ranging giraffes (Giraffa camelopardalis) in an attempt to better understand some of the medical issues seen with captive giraffes. Illnesses, including peracute mortality, energy malnutrition, pancreatic disease, urolithiasis, hoof disease, and severe intestinal parasitism, may be related to zoo nutrition and management issues. Serum samples were collected from 20 captive giraffes at 10 United States institutions. Thirteen of the captive animal samples were collected from animals trained for blood collection; seven were banked samples obtained from a previous serum collection. These samples were compared with serum samples collected from 24 free-ranging giraffes in South Africa. Differences between captive and free-ranging giraffes, males and females, and adults and subadults were analyzed by using a 2 x 2 x 2 factorial and Fisher's least significant difference for mean separation; when necessary variables were ranked and analyzed via analysis of variance. Potassium and bilirubin concentrations and alanine aminotransferase (ALT) activities were different between captive and free-ranging giraffes, but all fell within normal bovid reference ranges. The average glucose concentration was significantly elevated in free-ranging giraffes (161 mg/dl) compared with captive giraffes (113 mg/dl). All giraffes in this study had glucose concentrations higher than bovine (42-75 mg/ dl) and caprine (48-76 mg/dl) reference ranges. Differences were also seen in lipase, chloride, and magnesium though these findings are likely not clinically significant. There were no differences detected between sexes. Adults had higher concentrations of potassium, total protein, globulins, and chloride and higher gamma glutamyltransferase activities, whereas subadults had higher concentrations of phosphorus. Within the captive group, nonimmobilized animals had higher concentrations of total protein and globulins. Captive giraffe diets need further investigation to determine if the differences seen in this study, especially glucose and bilirubin concentrations and ALT activities, may result in some health problems often seen in captive giraffes.
Ergünay, Koray; Özkul, Aykut
2011-04-01
West Nile virus (WNV) infections may trigger febrile conditions and/or neuroinvasive disease in a portion of the exposed individuals. Serosurveillance data from various regions of Turkey indicate WNV activity. The aim of this study was to confirm the antibody specificity of the serum samples via virus neutralization assay, previously reported to be reactive for WNV IgM. The samples originated from two individuals with the preliminary diagnosis of aseptic meningitis/encephalitis of unknown etiology in 2009 and had been classified as probable WNV infections. Cerebrospinal fluid and sera samples of these patients had been evaluated as negative for WNV RNA and IgG antibodies. Only one serum sample could be included in the neutralization assay due to the limited amounts in the current investigation. The sample was observed as positive in dilutions of 1/20 and 1/40, thus confirming the diagnosis of WNV-related central nervous system infection in a 62 year-old female patient from Ankara, Central Anatolia, Turkey.
Feasibility of Using Convalescent Plasma Immunotherapy for MERS-CoV Infection, Saudi Arabia.
Arabi, Yaseen M; Hajeer, Ali H; Luke, Thomas; Raviprakash, Kanakatte; Balkhy, Hanan; Johani, Sameera; Al-Dawood, Abdulaziz; Al-Qahtani, Saad; Al-Omari, Awad; Al-Hameed, Fahad; Hayden, Frederick G; Fowler, Robert; Bouchama, Abderrezak; Shindo, Nahoko; Al-Khairy, Khalid; Carson, Gail; Taha, Yusri; Sadat, Musharaf; Alahmadi, Mashail
2016-09-01
We explored the feasibility of collecting convalescent plasma for passive immunotherapy of Middle East respiratory syndrome coronavirus (MERS-CoV) infection by using ELISA to screen serum samples from 443 potential plasma donors: 196 patients with suspected or laboratory-confirmed MERS-CoV infection, 230 healthcare workers, and 17 household contacts exposed to MERS-CoV. ELISA-reactive samples were further tested by indirect fluorescent antibody and microneutralization assays. Of the 443 tested samples, 12 (2.7%) had a reactive ELISA result, and 9 of the 12 had reactive indirect fluorescent antibody and microneutralization assay titers. Undertaking clinical trials of convalescent plasma for passive immunotherapy of MERS-CoV infection may be feasible, but such trials would be challenging because of the small pool of potential donors with sufficiently high antibody titers. Alternative strategies to identify convalescent plasma donors with adequate antibody titers should be explored, including the sampling of serum from patients with more severe disease and sampling at earlier points during illness.
Felten, Sandra; Leutenegger, Christian M; Balzer, Hans-Joerg; Pantchev, Nikola; Matiasek, Kaspar; Wess, Gerhard; Egberink, Herman; Hartmann, Katrin
2017-08-02
Feline coronavirus (FCoV) exists as two pathotypes, and FCoV spike gene mutations are considered responsible for the pathotypic switch in feline infectious peritonitis (FIP) pathogenesis. The aim of this study was to evaluate sensitivity and specificity of a real-time reverse transcriptase polymerase chain reaction (RT-PCR) specifically designed to detect FCoV spike gene mutations at two nucleotide positions. It was hypothesized that this test would correctly discriminate feline infectious peritonitis virus (FIPV) and feline enteric coronavirus (FECV). The study included 63 cats with signs consistent with FIP. FIP was confirmed in 38 cats. Twenty-five control cats were definitively diagnosed with a disease other than FIP. Effusion and/or serum/plasma samples were examined by real-time RT-PCR targeting the two FCoV spike gene fusion peptide mutations M1058 L and S1060A using an allelic discrimination approach. Sensitivity, specificity, negative and positive predictive values including 95% confidence intervals (95% CI) were calculated. FIPV was detected in the effusion of 25/59 cats, one of them being a control cat with chronic kidney disease. A mixed population of FIPV/FECV was detected in the effusion of 2/59 cats; all of them had FIP. RT-PCR was negative or the pathotype could not be determined in 34/59 effusion samples. In effusion, sensitivity was 68.6% (95% CI 50.7-83.2), specificity was 95.8% (95% CI 78.9-99.9). No serum/plasma samples were positive for FIPV. Although specificity of the test in effusions was high, one false positive result occurred. The use of serum/plasma cannot be recommended due to a low viral load in blood.
Maternal serum bisphenol A levels and risk of pre-eclampsia: a nested case-control study.
Ye, Yunzhen; Zhou, Qiongjie; Feng, Liping; Wu, Jiangnan; Xiong, Yu; Li, Xiaotian
2017-12-01
Although recent studies have indicated the potential adverse effects of maternal bisphenol A (BPA) exposure on pregnancy such as increasing the risk of pre-eclampsia, epidemiological evidence is limited. We aimed to evaluate the relationship between maternal BPA exposure and the risk of pre-eclampsia. We conducted a nested case-control study among 173 women (74 cases of pre-eclampsia and 99 controls). BPA concentrations were measured using liquid chromatography-mass spectrometry in the maternal serum samples collected during 16-20 gestational weeks. Multivariate logistic models were used to examine the relationship between maternal serum BPA concentrations and the risk of pre-eclampsia. BPA was detectable (>0.1 µg/l) in 78.6% of the maternal serum samples at three levels: low (<2.24 µg/l), medium (2.24-4.44 µg/l), and high (>4.44 µg/l). BPA concentrations were significantly higher in the serum samples collected from the pre-eclampsia cases than those from controls (median: 3.40 vs. 1.50 µg/l, P < 0.01). With adjustment for maternal age, primiparous and BMI, the odds of developing pre-eclampsia were significantly elevated in subjects with high serum BPA levels compared with those with low levels (adjusted OR = 16.46, 95%CI = 5.42-49.85) regardless of subcategories of pre-eclampsia including severity and onset time. Among the pre-eclampsia subjects, the maternal serum concentration of BPA was not different between the early- and late-onset subjects (median: 3.09 vs. 3.50 µg/l, P = 0.57), but surprisingly higher in mild pre-eclampsia subjects compared with severe pre-eclampsia subjects (median: 5.20 vs. 1.80 µg/l, P < 0.01). These results demonstrated that maternal exposure to high level of BPA could be associated with an increased risk of pre-eclampsia. © The Author 2017. Published by Oxford University Press on behalf of the European Public Health Association.
Maternal serum bisphenol A levels and risk of pre-eclampsia: a nested case–control study
Ye, Yunzhen; Zhou, Qiongjie; Feng, Liping; Wu, Jiangnan; Xiong, Yu; Li, Xiaotian
2017-01-01
Abstract Background Although recent studies have indicated the potential adverse effects of maternal bisphenol A (BPA) exposure on pregnancy such as increasing the risk of pre-eclampsia, epidemiological evidence is limited. We aimed to evaluate the relationship between maternal BPA exposure and the risk of pre-eclampsia. Methods We conducted a nested case–control study among 173 women (74 cases of pre-eclampsia and 99 controls). BPA concentrations were measured using liquid chromatography-mass spectrometry in the maternal serum samples collected during 16–20 gestational weeks. Multivariate logistic models were used to examine the relationship between maternal serum BPA concentrations and the risk of pre-eclampsia. Results BPA was detectable (>0.1 µg/l) in 78.6% of the maternal serum samples at three levels: low (<2.24 µg/l), medium (2.24-4.44 µg/l), and high (>4.44 µg/l). BPA concentrations were significantly higher in the serum samples collected from the pre-eclampsia cases than those from controls (median: 3.40 vs. 1.50 µg/l, P < 0.01). With adjustment for maternal age, primiparous and BMI, the odds of developing pre-eclampsia were significantly elevated in subjects with high serum BPA levels compared with those with low levels (adjusted OR = 16.46, 95%CI = 5.42–49.85) regardless of subcategories of pre-eclampsia including severity and onset time. Among the pre-eclampsia subjects, the maternal serum concentration of BPA was not different between the early- and late-onset subjects (median: 3.09 vs. 3.50 µg/l, P = 0.57), but surprisingly higher in mild pre-eclampsia subjects compared with severe pre-eclampsia subjects (median: 5.20 vs. 1.80 µg/l, P < 0.01). Conclusions These results demonstrated that maternal exposure to high level of BPA could be associated with an increased risk of pre-eclampsia. PMID:29186464
Comparison of serum Concentration of Se, Pb, Mg, Cu, Zn, between MS patients and healthy controls
Alizadeh, Anahita; Mehrpour, Omid; Nikkhah, Karim; Bayat, Golnaz; Espandani, Mahsa; Golzari, Alireza; Jarahi, Lida; Foroughipour, Mohsen
2016-01-01
Introduction Multiple Sclerosis (MS) is defined as one of the inflammatory autoimmune disorders and is common. Its exact etiology is unclear. There are some evidences on the role of environmental factors in susceptible genetics. The aim of this study is to evaluate the possible role of Selenium, Zinc, Copper, Lead and Magnesium metals in Multiple Sclerosis patients. Methods In the present analytical cross-sectional study, 56 individuals including 26 patients and 30 healthy controls were enrolled in the evaluation. The serum level of Se, Zn, Cu, Pb were quantified in graphite furnace conditions and flame conditions by utilizing an atomic absorption Perkin Elmer spectrophotometer 3030. The serum levels of Mg were measured by auto analyzer 1500 BT. The mean level of minerals (Zn, Pb, Cu, Mg, Se) in serum samples were compared in both cases and controls. The mean level of minerals (Zn, Pb, Cu, Mg, Se) in serum samples were compared in both cases and controls by using independent-samples t-test for normal distribution and Mann-Whitney U test as a non-parametric test. All statistical analyses were carried out using SPSS 11.0. Results As well as the Zn, Cu, and Se, there was no significant difference between MS patients and healthy individuals in Pb concentrations (p-value = 0.11, 0.14, 0.32, 0.20 respectively) but the level of Mg was significantly different (p= 0.001). Conclusion All serum concentrations of Zn, Pb, Se, Cu in both groups were in normal ranges and there was no difference in MS patients compared with the healthy group who were matched in genetics. Blood level of Mg was significantly lower in MS patients. But it should be noted that even with the low level of serum magnesium in MS patients, this value is still in the normal range. PMID:27757186
Ramos-Trautmann, Grisel; González, Lilliana; Díaz-Luquis, Giselle; Pérez, Cynthia M; Palacios, Cristina
2015-04-01
Vitamin D deficiency is a public health problem around the world. Diabetes has been associated with vitamin D deficiency. We aimed to examine the association between the vitamin D status and diabetes in a clinic based sample of Hispanic adults in Puerto Rico. Demographics and laboratory test results for serum 25(OH)D, Fasting Blood Glucose (FBG), and Haemoglobin A1C (HbAlc) were extracted from medical records. Vitamin D status was classified as deficient (<12 ng/ml); inadequate (12-20 ng/ml); insufficient (21-29 ng/ml) and optimal (≥30 ng/ml) using serum 25(OH)D levels. A total of 716 records were included in the analyses. Most were females (63.3%), with mean age of 54.1±14.9 y, mean BMI 30.1±6.3 kg/m2 and mean serum 25(OH)D levels of 24.3±8.6 ng/ml. Most were classified as diabetics (41.1%). Those with diabetes had lower 25(OH)D levels compared to pre-diabetic and normal glucose status (p<0.05). Serum 25(OH) D levels were inversely correlated to FBG and HbA1c in the total sample and in men (p<0.05). After adjusting for age, gender, BMI and seasonality, there was a greater risk of diabetes, but not prediabetes, in those with serum 25(OH)D levels <30 ng/ml. This risk increased from 1.8 times in those with vitamin D insufficiency to 4.2 times in those with vitamin D deficiency (<12 ng/ml). Diabetes risk significantly increased as serum 25(OH)D levels decreased in this group of Hispanic adults, underscoring the importance of routinely screening high risk individuals for vitamin D deficiency and offer supplementation to normalize serum levels.
Ramos-Trautmann, Grisel; González, Lilliana; Díaz-Luquis, Giselle; Pérez, Cynthia M.; Palacios, Cristina
2017-01-01
Background Vitamin D deficiency is a public health problem around the world. Diabetes has been associated with vitamin D deficiency. We aimed to examine the association between the vitamin D status and diabetes in a clinic based sample of Hispanic adults in Puerto Rico. Methods Demographics and laboratory test results for serum 25(OH)D, Fasting Blood Glucose (FBG), and Haemoglobin A1C (HbAlc) were extracted from medical records. Vitamin D status was classified as deficient (<12 ng/ml); inadequate (12–20 ng/ml); insufficient (21–29 ng/ml) and optimal (≥30 ng/ml) using serum 25(OH)D levels. Results A total of 716 records were included in the analyses. Most were females (63.3%), with mean age of 54.1±14.9 y, mean BMI 30.1±6.3 kg/m2 and mean serum 25(OH)D levels of 24.3±8.6 ng/ml. Most were classified as diabetics (41.1%). Those with diabetes had lower 25(OH)D levels compared to pre-diabetic and normal glucose status (p<0.05). Serum 25(OH) D levels were inversely correlated to FBG and HbA1c in the total sample and in men (p<0.05). After adjusting for age, gender, BMI and seasonality, there was a greater risk of diabetes, but not prediabetes, in those with serum 25(OH)D levels <30 ng/ml. This risk increased from 1.8 times in those with vitamin D insufficiency to 4.2 times in those with vitamin D deficiency (<12 ng/ml). Conclusion Diabetes risk significantly increased as serum 25(OH)D levels decreased in this group of Hispanic adults, underscoring the importance of routinely screening high risk individuals for vitamin D deficiency and offer supplementation to normalize serum levels. PMID:28345061
Hollmen, T.; Franson, J.C.; Hario, Martti; Sankari, S.; Kilpi, Mikael; Lindstrom, K.
2001-01-01
During 1997–1999, we collected serum samples from 156 common eider (Somateria mollissima) females incubating eggs in the Finnish archipelago of the Baltic Sea. We used serum chemistry profiles to evaluate metabolic changes in eiders during incubation and to compare the health and nutritional status of birds nesting at a breeding area where the eider population has declined by over 50% during the past decade, with birds nesting at two areas with stable populations. Several changes in serum chemistries were observed during incubation, including (1) decreases in serum glucose, total protein, albumin, β‐globulin, and γ‐globulin concentrations and (2) increases in serum uric acid, creatine kinase, and β‐hydroxybutyrate concentrations. However, these changes were not consistent throughout the 3‐yr period, suggesting differences among years in the rate of carbohydrate, lipid, and protein utilization during incubation. The mean serum concentrations of free fatty acids, glycerol, and albumin were lowest and the serum α‐ and γ‐globulin levels were highest in the area where the eider population has declined, suggesting a role for nutrition and diseases in the population dynamics of Baltic eiders.
Yapakçi, Ece; Ecevit, Ayşe; Gökmen, Zeynel; Tarcan, Aylin; Ozbek, Namik
2009-11-01
Hepcidin is a regulatory peptide hormone acts by limiting intestinal iron absorption and promoting iron retention. Determining the level of hepcidin in anemia of prematurity might be important in preventing iron overload. This study aimed to determine serum levels of prohepcidin in newborns with anemia of prematurity, to assess the effect of a single erythrocyte transfusion on serum prohepcidin levels, and to determine the possible relationships between prohepcidin levels and serum iron and complete blood count parameters. Nineteen premature newborns with anemia of prematurity who had been treated with erythrocyte transfusions were included in this study. Just before, and 48 hours after, each transfusion, venous blood samples were collected from patients. Serum prohepcidin levels before and after erythrocyte transfusion were 206.5+/-27.3 and 205.7+/-47.1 ng/mL, respectively; no statistically significant differences were found. No significant differences existed before or after transfusion regarding serum total iron and ferritin levels, iron-binding capacity, or mean corpuscular hemoglobin concentration. No significant correlations existed between serum prohepcidin levels and other parameters, either before or after transfusions. Our results showed that there were no statistically significant differences between serum prohepcidin levels before and after a single erythrocyte transfusion in premature newborns.
Agréus, Lars; Storskrubb, Tom; Aro, Pertti; Ronkainen, Jukka; Talley, Nicholas J; Sipponen, Pentti
2009-01-01
Proton-pump inhibitors (PPIs), H(2) receptor antagonists (H(2)RAs) and antacids/alginates reduce intragastric acidity and may thus influence normal gastric physiology. The purpose of this study was to examine the effect of these compounds on serum levels of amidated gastrin-17 (G-17) and pepsinogens (PGI & PGII) in a large, random, adult Swedish population sample with uninfected stomach mucosa. The initial sample subjects (n=1000, mean age 50 years, range 20-80 years) completed a questionnaire on the use of acid inhibitory drugs 1 week and/or 3 months before study entry. All subjects (n=590) with normal gastric mucosa as delineated by serum biomarkers were included. Among them, serum levels of PGI, PGII and G-17 were compared between those who used acid inhibitory drugs and those who did not. The serum levels of G-17 or pepsinogens in the subjects who reported use of H(2)RAs (n=18) or antacid/alginates (n=66) during the previous 3 months did not differ from those in non-users (n=471). However, the median levels of G-17 and pepsinogens were significantly (p<0.001) higher among the PPI users (n=35) than among non-users: the levels were approximately doubled. The ratio of PGI/PGII was, however, similar between PPI users and non-users, or those using antacids/alginates or H(2)RAs. Among subjects using PPIs, the serum levels of pepsinogens correlated positively (p<0.01) with the serum levels of G-17. PPIs but not antacids/alginates or H(2)RAs markedly increase the fasting levels of serum amidated G-17 and pepsinogens among ordinary patients in everyday clinical practice.
Kasaian, M T; Lee, J; Brennan, A; Danto, S I; Black, K E; Fitz, L; Dixon, A E
2018-04-17
A major goal of asthma therapy is to achieve disease control, with maintenance of lung function, reduced need for rescue medication, and prevention of exacerbation. Despite current standard of care, up to 70% of patients with asthma remain poorly controlled. Analysis of serum and sputum biomarkers could offer insights into parameters associated with poor asthma control. To identify signatures as determinants of asthma disease control, we performed proteomics using Olink proximity extension analysis. Up to 3 longitudinal serum samples were collected from 23 controlled and 25 poorly controlled asthmatics. Nine of the controlled and 8 of the poorly controlled subjects also provided 2 longitudinal sputum samples. The study included an additional cohort of 9 subjects whose serum was collected within 48 hours of asthma exacerbation. Two separate pre-defined Proseek Multiplex panels (INF and CVDIII) were run to quantify 181 separate protein analytes in serum and sputum. Panels consisting of 9 markers in serum (CCL19, CCL25, CDCP1, CCL11, FGF21, FGF23, Flt3L, IL-10Rβ, IL-6) and 16 markers in sputum (tPA, KLK6, RETN, ADA, MMP9, Chit1, GRN, PGLYRP1, MPO, HGF, PRTN3, DNER, PI3, Chi3L1, AZU1, and OPG) distinguished controlled and poorly controlled asthmatics. The sputum analytes were consistent with a pattern of neutrophil activation associated with poor asthma control. The serum analyte profile of the exacerbation cohort resembled that of the controlled group rather than that of the poorly controlled asthmatics, possibly reflecting a therapeutic response to systemic corticosteroids. Proteomic profiles in serum and sputum distinguished controlled and poorly controlled asthmatics, and were maintained over time. Findings support a link between sputum neutrophil markers and loss of asthma control. © 2018 John Wiley & Sons Ltd.
Liang, Si; Xu, Feng; Tang, Weibiao; Zhang, Zheng; Zhang, Wei; Liu, Lili; Wang, Junxia; Lin, Kuangfei
2016-08-01
Hair samples and paired serum samples were collected from e-waste and urban areas in Wenling of Zhejiang Province, China. The PBDE and DBDPE concentrations in hair and serum samples from e-waste workers were significantly higher than those of non-occupational residents and urban residents. BDE209 was the dominating BFRs in hair and serum samples from the e-waste area, while DBDPE was the major BFRs from the urban area. Statistically significant correlations were observed between hair level and serum level for some substances (BDE209, DBDPE, BDE99, BDE47, BDE28, and BDE17), although the PBDE congener profiles in hair were different from those in the serum. A statistically significant positive correlation between the PBDE concentrations and the working age, as well as gender difference, was observed in e-waste workers. Different sources of PBDEs and DBDPE in three groups were identified by principal component analysis and spearman correlation coefficient. Hair is suggested to be a useful matrix for biomonitoring the PBDE exposure in humans.
Litwiniuk, Małgorzata; Niemczyk, Kazimierz; Niderla-Bielińska, Justyna; Łukawska-Popieluch, Izabela; Grzela, Tomasz
2017-10-01
To assess the expression of endoglin in head and neck paragangliomas and the soluble endoglin level in serum of paraganglioma patients. Seven tumor samples of patients operated for cervical paraganglioma were assessed, as well as serum samples collected preoperatively, on days 4 and 28 postoperation. Serum level of endoglin in healthy controls was also determined. Tumor samples were subjected to immunofluorescent staining and examined with confocal microscope. The level of soluble endoglin in serum samples was examined using the immunoenzymatic assay (ELISA). Endoglin was highly expressed in all tumor samples. The level of soluble endoglin was significantly higher in paraganglioma patients compared to healthy controls and correlated with the tumor size. The serum level of s-endoglin was reduced after surgical excision of the tumor and remained stable after 4 weeks in all patients with complete resection of the tumor. Endoglin is an important factor in the pathophysiology of head and neck paragangliomas and may be a potential diagnostic and prognostic marker in these types of tumors.
Rosen, Jennifer B.; Doll, Margaret K.; McNall, Rebecca J.; McGrew, Marcia; Williams, Nobia; Lopareva, Elena N.; Barskey, Albert E.; Punsalang, Amado; Rota, Paul A.; Oleszko, William R.; Hickman, Carole J.; Zimmerman, Christopher M.; Bellini, William J.
2013-01-01
A mumps outbreak in upstate New York in 2009 at a summer camp for Orthodox Jewish boys spread into Orthodox Jewish communities in the Northeast, including New York City. The availability of epidemiologic information, including vaccination records and parotitis onset dates, allowed an enhanced analysis of laboratory methods for mumps testing. Serum and buccal swab samples were collected from 296 confirmed cases with onsets from September through December 2009. All samples were tested using the Centers for Disease Control and Prevention (CDC) capture IgM enzyme immunoassay (EIA) and a real-time reverse transcription-PCR (rRT-PCR) that targets the short hydrophobic gene. A subset of the samples (n = 205) was used to evaluate 3 commercial mumps IgM assays and to assess the sensitivity of using an alternative target gene (nucleoprotein) in the rRT-PCR protocol. Among 115 cases of mumps with 2 documented doses of measles, mumps, and rubella (MMR) vaccine, the CDC capture IgM EIA detected IgM in 51% of serum samples compared to 9% to 24% using three commercial IgM assays. The rRT-PCR that targeted the nucleoprotein gene increased RNA detection by 14% compared to that obtained with the original protocol. The ability to detect IgM improved when serum was collected 3 days or more after symptom onset, whereas sensitivity of RNA detection by rRT-PCR declined when buccal swabs were collected later than 2 days after onset. Selection of testing methods and timing of sample collection are important factors in the ability to confirm infection among vaccinated persons. These results reinforce the need to use virus detection assays in addition to serologic tests. PMID:23324519
Stafylis, Chrysovalantis; Klausner, Jeffrey D
2017-01-01
Fourth generation assays detect simultaneously antibodies for HIV and the p24 antigen, identifying HIV infection earlier than previous generation tests. Previous studies have shown that the Alere Determine HIV-1/2 Combo has lower than anticipated performance in detecting antibodies for HIV and the p24 antigen. Furthermore, there are currently very few studies evaluating the performance of Standard Diagnostics BIOLINE HIV Ag/Ab Combo. To evaluate the performance of the Alere Determine HIV-1/2 Combo and the Standard Diagnostics BIOLINE HIV Ag/Ab Combo in a panel of frozen serum samples. The testing panel included 133 previously frozen serum specimens from the UCLA Clinical Microbiology & Immunoserology laboratory. Reference testing included testing for HIV antibodies by a 3rd generation enzyme immunoassay followed by HIV RNA detection. Antibody negative and RNA positive sera were also tested by a laboratory 4th generation HIV Ab/Ag enzyme immunoassay. Reference testing yielded 97 positives for HIV infection and 36 negative samples. Sensitivity of the Alere test was 95% (88-98%), while the SD Bioline sensitivity was 91% (83-96%). Both assays showed 100% (90-100%) specificity. No indeterminate or invalid results were recorded. Among 13 samples with acute infection (HIV RNA positive, HIV antibody negative), 12 were found positive by the first assay and 8 by the second. The antigen component of the Alere assay detected 10 acute samples, while the SD Bioline assay detected only one. Both rapid assays showed very good overall performance in detecting HIV infection in frozen serum samples, but further improvements are required to improve the performance in acute infection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyle, Jennifer E.; Casey, Cameron P.; Stratton, Kelly G.
The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules weremore » identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.« less
Evaluation of automated assays for immunoglobulin G, M, and A measurements in dog and cat serum.
Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Caldin, Marco; Tecles, Fernando; Ceron, Jose J
2013-09-01
Measurements of immunoglobulins (Igs) in companion animals can be useful to detect deficiencies of the humoral immune system, that can be associated with opportunistic or chronic infections, or other immune-mediated disorders including B-cell neoplasms. The purpose of this study was to evaluate commercially available automated immunoturbidimetric assays designed for human IgG, M, and A measurements in canine and feline serum using species-specific calibrators. Canine and feline serum samples with different IgG, M, and A concentrations were used for the analytical validation of the assays. Intra- and inter-assay precision, linearity under dilution, spiking recovery, and limit of detection were determined. In addition, effects of lipemia, hemolysis, and bilirubinemia were evaluated. Finally, Ig concentrations were determined in small groups of diseased dogs and cats, and compared with healthy groups. Spiking recovery and linearity under dilution tests showed that the assays measured Igs in canine and feline serum samples precisely and accurately. Intra- and inter-assay imprecisions were lower than 15% in all cases. Significantly higher IgG, IgM, and IgA levels were observed in dogs with leishmaniasis, while dogs with pyometra showed a statistically significant increase in IgM and IgA concentrations in comparison with healthy dogs. Significantly higher IgG and IgM levels were observed in FIV-infected cats compared with healthy ones. The automated human Ig assays showed adequate precision and accuracy with serum samples from dogs and cats. Also, they were able to discriminate different concentrations of Igs in healthy and diseased animals. © 2013 American Society for Veterinary Clinical Pathology.
Pavlica, Zlatko; Petelin, Milan; Nemec, Alenka; Erzen, Damjan; Skaleric, Uros
2004-11-01
To determine whether gingival crevicular fluid (GCF) and serum total antioxidant capacities (TACs) correlate with the degree of severity of periodontal disease in dogs. 41 Toy and Miniature Poodles. After assessment of the degree of severity of naturally occurring periodontitis, GCF samples from both maxillary fourth premolars and a blood sample were collected from each dog. The condition of the periodontium of the entire dentition and at each site of GCF collection was recorded. Clinical parameters assessed included plaque index, gingival index, and probing depth. Radiographic analysis of alveolar bone level was also performed. Total antioxidant capacity was measured in GCF and serum samples by use of a commercial kit. Dogs with gingivitis and minimal periodontitis had significantly higher TAC in GCF than dogs with advanced periodontitis. Bivariate regression analysis revealed significant negative correlations between TAC in GCF and clinical parameters and age. The TAC in serum was significantly negatively correlated with the degree of gingival inflammation but was not significantly correlated with age. TAC in GCF is related to the degree of severity of periodontal disease in dogs. This is likely the result of release of reactive oxygen species by activated phagocytes and fibroblasts in the inflamed periodontal tissues. The results of our study suggest that the local delivery of antioxidants may be a useful adjunctive treatment for periodontitis in dogs.
Ayache, Saleh; Panelli, Monica C; Byrne, Karen M; Slezak, Stefanie; Leitman, Susan F; Marincola, Francesco M; Stroncek, David F
2006-01-01
Background The culture and expansion of human cells for clinical use requires the presence of human serum or plasma in culture media. Although these supplements have been extensively characterized in their chemical composition, only recently it has been possible to provide by high throughput protein analysis, a comprehensive profile of the soluble factors contributing to cell survival. This study analyzed and compared the presence of 100 proteins including chemokines, cytokines and soluble factors in six different types of media supplements: serum, plasma, recalcified plasma, heat inactivated serum, heat inactivated plasma and heat inactivated recalcified plasma. Methods Serum, plasma, recalcified plasma, and heat inactivated supplements were prepared from ten healthy subjects. The levels of 100 soluble factors were measured in each sample using a multiplexed ELISA assay and compared by Eisen hierarchical clustering analysis. Results A comparison of serum and plasma levels of soluble factors found that 2 were greater in plasma but 18 factors were greater in serum including 11 chemokines. The levels of only four factors differed between recalcified plasma and plasma. Heat inactivation had the greatest effect on soluble factors. Supervised Eisen hierarchical clustering indicated that the differences between heat inactivated supplements and those that were not were greater than the differences within these two groups. The levels of 36 factors differed between heat inactivated plasma and plasma. Thirty one of these factors had a lower concentration in heat inactivated plasma including 12 chemokines, 4 growth factors, 4 matrix metalloproteases, and 3 adhesion molecules. Heat inactivated decalcified plasma is often used in place of heat inactivated serum and the levels of 19 soluble factors differed between these two supplements. Conclusion Our report provides a comprehensive protein profile of serum, plasma recalcified plasma, and heat inactivated supplements. This profile represents a qualitative and quantitative database that can aid in the selection of the appropriate blood derived supplement for human cell cultures with special requirements. PMID:17020621
Maki, Katsuyuki; Watabe, Etsuko; Iguchi, Yumi; Nakamura, Hideko; Tomishima, Masaki; Ohki, Hidenori; Yamada, Akira; Matsumoto, Satoru; Ikeda, Fumiaki; Tawara, Shuichi; Mutoh, Seitaro
2006-01-01
To establish an in vitro method of predicting in vivo efficacy of antifungal drugs against Candida albicans and Aspergillus fumigatus, the antifungal activities of fluconazole, itraconazole, and amphotericin B were determined in mouse serum. The minimum inhibitory concentration (MIC) of each drug was measured using mouse serum as a diluent. For C. albicans, the assay endpoint of azoles was defined as inhibition of mycelial extension (mMIC) and for A. fumigatus, as no growth (MIC). The MICs of amphotericin B for both pathogens were defined as the MIC at which no mycelial growth occurred. Serum MIC or mMIC determinations were then used to estimate the concentration of the drugs in serum of mice treated with antifungal drugs by multiplying the antifungal titer of the serum samples by the serum (m)MIC. The serum drug concentrations were also determined by HPLC. The serum concentrations estimated microbiologically showed good agreement with those determined by HPLC, except for itraconazole. Analysis of the serum samples from itraconazole-treated mice by a sensitive bioautography revealed the presence of additional spots, not seen in control samples of itraconazole. The bioautography assay demonstrated that the additional material detected in serum from mice treated with itraconazole was an active metabolite of itraconazole. The data showed that the apparent reduction in the itraconazole serum concentration as determined by HPLC was the result of the formation of an active metabolite, and that the use of a microbiological method to measure serum concentrations of drugs can provide a method for prediction of in vivo efficacy of antifungal drugs.
Davies, R H; Heath, P J; Coxon, S M; Sayers, A R
2003-01-01
Monitoring for Salmonella in slaughter pigs is important to enable targeted control measures to be applied on problem farms and at the abattoir. The aim of this study was to determine whether pooled serum and meat juice could be used to identify finishing pig herds with a high prevalence of infection. Samples of meat juice, serum, caecal contents, carcase swabs and pooled faeces from pig pens were taken from 20 commercial pig finishing farms and comparisons were made between the results of Salmonella culture, individual ELISA tests on serum and meat juice and pooled samples of serum and meat juice. Salmonella was isolated from samples from 19 of 20 farms. None of the ELISA tests showed a statistically significant correlation with caecal carriage of Salmonella or contamination of carcases. Serum mean optical density (O.D.) from pools of five, 10 or 20 sera showed a significant correlation with the Salmonella status of farm pen faeces. All pooled serum O.D. and sample/positive control ratio results correlated significantly with the results of the conventional individual sample ELISA. There was a statistically significant correlation between the incidence of Salmonella in farm pen pooled faeces and the prevalence of Salmonella in caeca of slaughter pigs. The results show a generally poor correlation between serological and bacteriological results but pooled serum or meat juice samples could be used as a cheaper substitute for serological screening of farms for Salmonella than individual samples. The availability of a cheaper test should allow the costs of Salmonella monitoring of pig farms to be reduced or allow more regular testing to enhance the designation of farm Salmonella risk status.
Detection of Serum microRNAs From Department of Defense Serum Repository
Woeller, Collynn F.; Thatcher, Thomas H.; Van Twisk, Daniel; Pollock, Stephen J.; Croasdell, Amanda; Kim, Nina; Hopke, Philip K.; Xia, Xiaoyan; Thakar, Juilee; Mallon, COL Timothy M.; Utell, Mark J.; Phipps, Richard P.
2017-01-01
Objective The aim of this study was to investigate whether serum samples from the Department of Defense Serum Repository (DoDSR) are of sufficient quality to detect microRNAs (miRNAs), cytokines, immunoglobulin E (IgE), and polycyclic aromatic hydrocarbons (PAHs). Methods MiRNAs were isolated and quantified by polymerase chain reaction (PCR) array. Cytokines and chemokines related to inflammation were measured using multiplex immunoassays. Cotinine and IgE were detected by enzyme-linked immunoassay (ELISA) and PAHs were detected by Liquid Chromatography/Mass Spectroscopy. Results We detected miRNAs, cytokines, IgE, and PAHs with high sensitivity. Eleven of 30 samples tested positive for cotinine suggesting tobacco exposure. Significant associations between serum cotinine, cytokine, IgE, PAHs, and miRNA were discovered. Conclusion We successfully quantified over 200 potential biomarkers of occupational exposure from DoDSR samples. The stored serum samples were not affected by hemolysis and represent a powerful tool for biomarker discovery and analysis in retrospective studies. PMID:27501106
Hepatotoxicosis in dogs consuming a diet of camel meat contaminated with indospicine.
FitzGerald, L M; Fletcher, M T; Paul, A E H; Mansfield, C S; O'Hara, A J
2011-03-01
Four dogs presented with clinical signs of severe hepatic disease after consuming a commercial camel meat diet. Laboratory investigation revealed evidence of severe liver disease, including markedly increased serum alanine aminotransferase (ALT) activity and total bilirubin concentration, and prolonged clotting times. Two dogs deteriorated despite supportive therapy and were euthanased. Histologically, both livers appeared similar, with the main lesion being extensive periacinar necrosis and haemorrhage. Indospicine, a toxic amino acid of plant origin, was detected in the serum and/or plasma from all four dogs, as well as in tissues of a dog that was necropsied and in a sample of the camel meat fed to this animal. Serum biochemistry tests using blood samples collected from 15 additional dogs identified as having eaten the diet detected indospicine was in the serum of 14 and 3 had increased ALT activity. One of the latter dogs subsequently developed clinical signs of severe liver disease and was euthanased. To the authors' knowledge, this is the first published report of the detection of indospicine residues in camel meat and the occurrence of severe, sometimes fatal, liver disease in dogs that consumed this contaminated meat. © 2011 The Authors. Australian Veterinary Journal © 2011 Australian Veterinary Association.
Salivary alterations in insulin-dependent diabetes mellitus.
Belazi, M A; Galli-Tsinopoulou, A; Drakoulakos, D; Fleva, A; Papanayiotou, P H
1998-03-01
To examine the flow rate and composition of unstimulated whole saliva and of serum in children with newly diagnosed insulin-dependent diabetes mellitus (IDDM) and to compare these with values for a group of healthy controls. Cross-sectional. Diabetic Department of a University Hospital in Thessaloniki, Greece. The test group was made up of 10 recently diagnosed child patients with IDDM, aged 4-15 years and free of other systemic disease. Ten healthy children aged 5-17 years served as controls. Children were clinically examined before unstimulated saliva was collected over a 5 minute period and blood samples taken. Saliva and serum measurements included glucose, total proteins, albumin and immunoglobulins (IgA, IgG). No significant difference was seen in salivary flow rate between the two groups. Significantly greater concentrations of glucose were seen in saliva and serum in children with IDDM. Neither total protein nor albumin differed significantly between the two groups. Salivary IgA concentration was higher in the test group as was serum IgG. Findings in this sample suggest that changes in salivary composition may, together with estimated glucose levels, play a helpful diagnostic role in the early stages of IDDM in some children.
NASA Astrophysics Data System (ADS)
Rocha-Osornio, L. N.; Pichardo-Molina, J. L.; Barbosa-Garcia, O.; Frausto-Reyes, C.; Araujo-Andrade, C.; Huerta-Franco, R.; Gutiérrez-Juárez, G.
2008-02-01
Raman spectroscopy and Multivariate methods were used to study serum blood samples of control and breast cancer patients. Blood samples were obtained from 11 patients and 12 controls from the central region of Mexico. Our results show that principal component analysis is able to discriminate serum sample of breast cancer patients from those of control group, also the loading vectors of PCA plotted as a function of Raman shift shown which bands permitted to make the maximum discrimination between both groups of samples.
Elevated Serum GAD65 and GAD65-GADA Immune Complexes in Stiff Person Syndrome.
Gu Urban, Gucci Jijuan; Friedman, Mikaela; Ren, Ping; Törn, Carina; Fex, Malin; Hampe, Christiane S; Lernmark, Åke; Landegren, Ulf; Kamali-Moghaddam, Masood
2015-06-16
Glutamic acid decarboxylase 65 (GAD65) and autoantibodies specific for GAD65 (GADA) are associated with autoimmune diseases including Stiff Person Syndrome (SPS) and Type 1 diabetes (T1D). GADA is recognized as a biomarker of value for clinical diagnosis and prognostication in these diseases. Nonetheless, it remains medically interesting to develop sensitive and specific assays to detect GAD65 preceding GADA emergence, and to monitor GADA-GAD65 immune complexes in blood samples. In the present study, we developed a highly sensitive proximity ligation assay to measure serum GAD65. This novel assay allowed detection of as little as 0.65 pg/ml GAD65. We were also able to detect immune complexes involving GAD65 and GADA. Both free GAD65 and GAD65-GADA levels were significantly higher in serum samples from SPS patients compared to healthy controls. The proximity ligation assays applied for detection of GAD65 and its immune complexes may thus enable improved diagnosis and better understanding of SPS.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study.
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Vazquez-Rosales, Guillermo; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Cevallos, Ana Maria; Xoconostle-Cazares, Beatriz; Lira, Rosalia
2017-01-01
Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µ l of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µ l. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Xoconostle-Cazares, Beatriz
2017-01-01
Background Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Methods Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion DSS samples are useful for detecting anti-dengue IgG antibodies in the field. PMID:28630868
Hecker, Michael; Fitzner, Brit; Wendt, Matthias; Lorenz, Peter; Flechtner, Kristin; Steinbeck, Felix; Schröder, Ina; Thiesen, Hans-Jürgen; Zettl, Uwe Klaus
2016-01-01
Intrathecal immunoglobulin G (IgG) synthesis and oligoclonal IgG bands in cerebrospinal fluid (CSF) are hallmarks of multiple sclerosis (MS), but the antigen specificities remain enigmatic. Our study is the first investigating the autoantibody repertoire in paired serum and CSF samples from patients with relapsing-remitting MS (RRMS), primary progressive MS (PPMS), and other neurological diseases by the use of high-density peptide microarrays. Protein sequences of 45 presumed MS autoantigens (e.g. MOG, MBP, and MAG) were represented on the microarrays by overlapping 15mer peptides. IgG reactivities were screened against a total of 3991 peptides, including also selected viral epitopes. The measured antibody reactivities were highly individual but correlated for matched serum and CSF samples. We found 54 peptides to be recognized significantly more often by serum or CSF antibodies from MS patients compared with controls (p values <0.05). The results for RRMS and PPMS clearly overlapped. However, PPMS patients presented a broader peptide-antibody signature. The highest signals were detected for a peptide mapping to a region of the Epstein-Barr virus protein EBNA1 (amino acids 392–411), which is homologous to the N-terminal part of human crystallin alpha-B. Our data confirmed several known MS-associated antigens and epitopes, and they delivered additional potential linear epitopes, which await further validation. The peripheral and intrathecal humoral immune response in MS is polyspecific and includes antibodies that are also found in serum of patients with other diseases. Further studies are required to assess the pathogenic relevance of autoreactive and anti-EBNA1 antibodies as well as their combinatorial value as biomarkers for MS. PMID:26831522
Goh, Charlene E; Kopp, Jacob; Papapanou, Panos N; Molitor, Jerry A; Demmer, Ryan T
2016-10-01
Alterations in the microbiome, including the periodontal microbiome, may be a risk factor for rheumatoid arthritis (RA). Most studies that have analyzed this association are relatively small, focus primarily on a single periodontal pathogen (Porphyromonas gingivalis), and are not population based. This study was undertaken to investigate the association between elevated serum levels of IgG antibodies to 19 periodontal species and the prevalence of rheumatoid factor (RF) in a large nationally representative sample of adults. The Third National Health and Nutrition Examination Survey (NHANES-III) is a cross-sectional sample of the noninstitutionalized US population (n = 33,994). Our study population included all dentate participants who were 60 years and older, did not have RA as defined by a modified version of the American College of Rheumatology 1987 criteria, and had complete data for both serum IgG antibodies against periodontal bacteria and serum RF antibody titer (n = 2,461). Adjusted odds ratios (ORs) and 95% confidence intervals (95% CIs) summarizing the relationship between the 19 periodontal serum IgG antibodies and RF seropositivity ranged from 0.53 (95% CI 0.29-0.97) to 1.27 (95% CI 0.79-2.06), and 17 of the 19 observed ORs were <1.0. The ORs for RF seropositivity among participants with elevated Prevotella intermedia (0.53 [95% CI 0.29-0.97]) and Capnocytophaga ochracea (0.54 [0.31-0.95]) IgG levels were statistically significant. Our findings indicate that elevated levels of IgG antibodies to periodontal bacteria are mostly unassociated with RF seropositivity in the nationally representative NHANES-III. Elevated levels of antibodies to P intermedia and C ochracea are associated with lower odds of RF seropositivity. © 2016, American College of Rheumatology.
Fan, Lihong; Qi, Huiwei; Teng, Junliang; Su, Bo; Chen, Hao; Wang, Changhui; Xia, Qing
2016-06-01
Circulating microRNAs (miRNAs) are potential noninvasive biomarkers for cancer detection. We used preoperative serum samples from non-small cell lung cancer (NSCLC) patients and healthy controls to investigate whether serum levels of candidate miRNAs could be used as diagnostic biomarkers in patients with resectable NSCLC and whether they were associated with clinicopathologic characteristics. We initially detected expression of 12 miRNAs using quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) in preoperative serum samples of 94 NSCLC patients and 58 healthy controls. We further validated our results using the fluorescence quantum dots liquid bead array for differentially expressed miRNAs in serum samples of 70 NSCLC patients and 54 healthy controls. Receiver operating characteristic (ROC) analysis was performed to select the best diagnostic miRNA cutoff value. A predictive model of miRNAs for NSCLC was derived by multivariate logistic regression. We found that five serum miRNAs (miR-16-5p, miR-17b-5p, miR-19-3p, miR-20a-5p, and miR-92-3p) were significantly downregulated in NSCLC, while miR-15b-5p was significantly upregulated (p < 0.05). Multivariate logistic regression analysis revealed that miR-15b-5p, miR-16-5p, and miR-20a-5p expression were independent diagnostic factors for the identification of patients with NSCLC after adjustment for patient's age and sex. In addition, the expression of serum miR-106-5p was higher in stage I than in stages IIa-IIIb, and no significant association was observed between expression of miRNAs and other variables including pathological type, tumor size, and lymph nodes status. Six serum miRNAs could potentially serve as noninvasive diagnostic biomarkers for resectable NSCLC. The predictive model combining miR-15b-5p, miR-16-5p, and miR-20a-5p was the best diagnostic approach.
Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc
2018-04-06
Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.
Preanalytical stability of maternal serum markers hCGβ and PAPP-A.
Veyrat, Béatrice; Tosetti, François; Morin, Jean-François; Moineau, Marie-Pierre; Piedimonte, Andrée; Clément, Patrice; Dreux, Sophie; Muller, Françoise
2017-04-01
Down syndrome maternal serum marker screening is based on a risk calculation including the free β - human chorionic gonadotropin (hCGβ) and pregnancy-associated placenta protein type A (PAPP-A). The aim of this study was to define the pre-analytical conditions of stability of these markers both in whole blood at 15-25 ̊C and, after centrifugation, in serum at 4-8 ̊C. 158 patients were included in the study. Two automated workstations were used for assays, Cobas 8000e602, Roche Diagnostics (58 patients tested) and DELFIAXpress, PerkinElmer (100 patients tested). The stability of markers was studied in whole blood (15-25 ̊C) 2, 4, 6 and 8 hours after sampling and in serum stored after centrifugation at 4-8 ̊C at 24, 72 and 120 hours. Variations were defined by (C T - C 2 )/C 2 , C 2 being the marker concentration at 2 hours and C T the concentration at time T. In whole blood kept for 8 hours at 15-25 ̊C, hCGβ increased by a mean 2.4%, whereas the mean increase of PAPP-A was < 1%. In the serum kept for 5 days at 4-8̊C, the mean increase of hCGβ was 4.2%, with no change in PAPP-A. The impact of these variations on risk calculation is low. In conclusion, maternal serum can be store 8 hours at 15-25̊C in whole blood and 5 days at 4-8̊C after centrifugation and serum separation for Down syndrome maternal serum screening.
Bjermo, Helena; Aune, Marie; Cantillana, Tatiana; Glynn, Anders; Lind, P Monica; Ridefelt, Peter; Darnerud, Per Ola
2017-01-01
The aim of this study was to investigate associations between serum concentrations of brominated flame retardants and personal characteristics, including diet, in adults participating in a population-based study in Sweden 2010-11. Moreover, observed concentrations were used in a health risk assessment, using published health-based reference values. Serum samples of 170 adult individuals of both sexes were analyzed for 10 PBDE congeners and HBCD by GC-MS. When including concentrations between LOD and LOQ, highest median serum concentration was observed for BDE-153 (1.2 ng/g serum lipid), followed by BDE-209 (0.95 ng/g lipid), BDE-47 (0.49 ng/g lipid) and BDE-100 (0.21 ng/g lipid). Median concentration of HBCD was 0.10 ng/g lipid. A few markedly elevated concentrations of BDE-209, HBCD (77-78 ng/g lipid) and BDE-47 (44 ng/g lipid) were observed. The only statistical significant findings were higher BDE-153 concentrations in men than in women, and positive associations between serum BDE-153 concentrations and consumption of fish (total), beef, mutton and poultry. PBDE concentrations were in accordance with concentrations reported in other European countries but generally lower than those found in North America. Median PBDE serum concentrations observed in adults from Sweden suggest sufficient health protection, when compared with published health-based reference values, although some outliers with high serum concentrations had lower safety margins. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Jensen, Berit P; Saraf, Rajneeta; Ma, Jing; Berry, Sarah; Grant, Cameron C; Camargo, Carlos A; Sies, Christiaan W
2018-06-01
Demand for measurement of 25-hydroxyvitamin D (25OHD) is growing and dried blood spot (DBS) sampling is attractive as samples are easier to collect, transport and store. A 2D LC-MS/MS assay without derivatization was developed. DBS punches (3.2 mm) were ultrasonicated with d 6 -25OHD 3 in 70% methanol followed by hexane extraction, dry-down and reconstitution. The assay was validated and applied to two studies comparing whole blood adult DBS with serum samples (n = 40) and neonatal whole blood DBS with cord serum samples (n = 80). The assay was validated in whole blood DBS over the range 13-106 nmol/L 25OHD 3 and 11-91 nmol/L 25OHD 2 with a limit of detection of 3 nmol/L. Intra- and inter-day imprecision was <13% CV and bias <12%. The assay had high recovery and minimal matrix effects. Triplicate DBS study samples had a mean CV of ≤13% for 25OHD 3. No 25OHD 2 was detected. DBS calculated serum 25OHD 3 concentrations correlated strongly with serum concentrations in the adult DBS/serum study (r = 0.94) and moderately in the neonatal DBS/cord serum study (r = 0.69). Direct quantitation of 25OHD in DBS by 2D LC-MS/MS without derivatization was found to be an alternative to serum quantitation applicable to clinical research studies on adult DBS samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Macro TSH in patients with subclinical hypothyroidism.
Hattori, Naoki; Ishihara, Takashi; Yamagami, Keiko; Shimatsu, Akira
2015-12-01
TSH is a sensitive indicator of thyroid function. In subclinical hypothyroidism, however, serum TSH concentrations are elevated despite normal thyroid hormone levels, and macro TSH is one of the causes. This study aimed to clarify the prevalence and nature of macro TSH in patients with subclinical hypothyroidism. We conducted a 2-year cross-sectional observational study. We included 681 patients with subclinical hypothyroidism and 38 patients with overt hypothyroidism (controls). Macro TSH was screened by polyethylene glycol (PEG) method and analysed by gel filtration chromatography and bioassays. Among 681 serum samples, 117 exhibited PEG-precipitable TSH ratios greater than 75% (mean + 1·5 SD in controls) and were subjected to gel filtration chromatography. TSH was eluted at a position greater than 100 kDa in 11 patients with subclinical hypothyroidism (1·62%); these patients were diagnosed with macro TSH. The nature of macro TSH included eight anti-TSH autoantibodies of IgG class, two non-IgG-associated and one human anti-mouse antibody (HAMA). Macro TSH showed low bioactivity. Macro TSH was heterogeneous, but it is mostly comprised of TSH and anti-TSH autoantibodies. When PEG-precipitable TSH exceeds 90% in serum samples with TSH above 10 mU/l, clinicians should strongly suspect the presence of macro TSH and confirm it by gel chromatography. Because macro TSH exhibited low bioactivity, thyroid hormone replacement therapy may not be required in patients with subclinical hypothyroidism due to macro TSH except for those with high serum free TSH levels. © 2014 John Wiley & Sons Ltd.
Höllig, Anke; Stoffel-Wagner, Birgit; Clusmann, Hans; Veldeman, Michael; Schubert, Gerrit A; Coburn, Mark
2017-01-01
Aneurysmal subarachnoid hemorrhage triggers an intense inflammatory response, which is suspected to increase the risk for secondary complications such as delayed cerebral ischemia (DCI). However, to date, the monitoring of the inflammatory response to detect secondary complications such as DCI has not become part of the clinical routine diagnostic. Here, we aim to illustrate the time courses of inflammatory parameters after aneurysmal subarachnoid hemorrhage (aSAH) and discuss the problems of inflammatory parameters as biomarkers but also their possible relevance for deeper understanding of the pathophysiology after aSAH and sophisticated planning of future studies. In this prospective cohort study, 109 patients with aSAH were initially included, n = 28 patients had to be excluded. Serum and-if possible-cerebral spinal fluid samples ( n = 48) were retrieved at days 1, 4, 7, 10, and 14 after aSAH. Samples were analyzed for leukocyte count and C-reactive protein (CRP) (serum samples only) as well as matrix metallopeptidase 9 (MMP9), intercellular adhesion molecule 1 (ICAM1), and leukemia inhibitory factor (LIF) [both serum and cerebrospinal fluid (CSF) samples]. Time courses of the inflammatory parameters were displayed and related to the occurrence of DCI. We illustrate the time courses of leukocyte count, CRP, MMP9, ICAM1, and LIF in patients' serum samples from the first until the 14th day after aSAH. Time courses of MMP9, ICAM1, and LIF in CSF samples are demonstrated. Furthermore, no significant difference was shown relating the time courses to the occurrence of DCI. We estimate that the wide range of the measured values hampers their interpretation and usage as a biomarker. However, understanding the inflammatory response after aSAH and generating a multicenter database may facilitate further studies: realistic sample size calculations on the basis of a multicenter database will increase the quality and clinical relevance of the acquired results.
Vijaylakshmi, P; Muthukkaruppan, V R; Rajasundari, A; Korukluoglu, G; Nigatu, W; L A Warrener; Samuel, D; Brown, D W G
2006-12-01
Clinical diagnosis (surveillance) of rubella is unreliable and laboratory confirmation is essential. Detection of virus specific IgM in serum is the most commonly used method. However, the use of serum necessitates the drawing of blood, either through venipuncture or finger/heel prick, which can be difficult in young babies. Oral fluid samples have proved useful as an alternative, less invasive sample for virus specific IgM detection however until recently no commercial rubella IgM tests were available, restricting the usefulness of this approach. To evaluate the performance of the Microimmune Rubella IgM capture EIA using oral fluid samples from outbreaks as well as in cases of suspected congenital rubella syndrome (CRS). Paired serum and oral fluids were collected from cases during a rubella outbreak in three provinces in Turkey. Matched serum and oral fluid samples were collected from children with suspected CRS in an active surveillance programme at the Aravind Eye Hospital in South India. Serum samples were collected as part of the measles surveillance programme in Ethiopia. On serum samples the sensitivity and specificity of the Microimmune Rubella IgM capture EIA compared to Behring Enzygnost rubella IgM test was 96.9% (62/64; 95% CI 94.2-100%) and 100% (53/53; 95% CI 93.2-100%). On oral fluids compared to matched Behring results on serum the sensitivity was 95.5% (42/44; 95% CI 84.5-99.4%). The sensitivity and specificity of Microimmune Rubella IgM capture EIA on oral fluids from suspected CRS cases compared to serum results using Behring Enzygnost IgM assay was 100% (95% CI 84.5-100%) and 100% (95% CI 95.8-100.0%) respectively. Microimmune Rubella IgM capture EIA has adequate performance for diagnosis and surveillance of rubella in outbreak using either serum or oral fluid specimens.
Bradbury, Kathryn E; Crowe, Francesca L; Appleby, Paul N; Schmidt, Julie A; Travis, Ruth C; Key, Timothy J
2013-01-01
BACKGROUND The objective of this study was to describe serum lipid concentrations, including apolipoproteins A-I and B, in different diet groups. METHODS A cross-sectional analysis of a sample of 424 meat-eaters, 425 fish-eaters, 423 vegetarians, and 422 vegans, matched on sex and age, from the European Prospective Investigation into Cancer and Nutrition (EPIC)-Oxford cohort. Serum concentrations of total, and HDL cholesterol, as well as apolipoproteins A-I and B were measured, and serum non-HDL cholesterol was calculated. RESULTS Vegans had the lowest BMI, and the highest and lowest intakes of polyunsaturated and saturated fat, respectively. After adjustment for age, alcohol and physical activity, compared to meat-eaters, fish-eaters and vegetarians, serum concentrations of total and non-HDL cholesterol, and apolipoprotein B were significantly lower in vegans. Serum apolipoprotein A-I concentrations did not differ between the diet groups. In males, the mean serum total cholesterol concentration was 0.87 nmol/L lower in vegans than in meat-eaters; after further adjustment for BMI this difference was 0.76 nmol/L. In females, the difference in total cholesterol between these two groups was 0.60 nmol/L, and after further adjustment for BMI was 0.55 nmol/L. CONCLUSIONS In this study, which included a large number of vegans, serum total cholesterol and apolipoprotein B concentrations were lower in vegans compared to meat-eaters, fish-eaters and vegetarians. A small proportion of the observed differences in serum lipid concentrations was explained by differences in BMI, but a large proportion is most likely due to diet. PMID:24346473
Bradbury, K E; Crowe, F L; Appleby, P N; Schmidt, J A; Travis, R C; Key, T J
2014-02-01
The objective of this study was to describe serum lipid concentrations, including apolipoproteins A-I and B, in different diet groups. A cross-sectional analysis of a sample of 424 meat-eaters, 425 fish-eaters, 423 vegetarians and 422 vegans, matched on sex and age, from the European Prospective Investigation into Cancer and Nutrition-Oxford cohort. Serum concentrations of total, and high-density lipoprotein (HDL) cholesterol, as well as apolipoproteins A-I and B were measured, and serum non-HDL cholesterol was calculated. Vegans had the lowest body mass index (BMI) and the highest and lowest intakes of polyunsaturated and saturated fat, respectively. After adjustment for age, alcohol and physical activity, compared with meat-eaters, fish-eaters and vegetarians, serum concentrations of total and non-HDL cholesterol and apolipoprotein B were significantly lower in vegans. Serum apolipoprotein A-I concentrations did not differ between the diet groups. In males, the mean serum total cholesterol concentration was 0.87 mmol/l lower in vegans than in meat-eaters; after further adjustment for BMI this difference was 0.76 mmol/l. In females, the difference in total cholesterol between these two groups was 0.6 mmol/l, and after further adjustment for BMI was 0.55 mmol/l. [corrected]. In this study, which included a large number of vegans, serum total cholesterol and apolipoprotein B concentrations were lower in vegans compared with meat-eaters, fish-eaters and vegetarians. A small proportion of the observed differences in serum lipid concentrations was explained by differences in BMI, but a large proportion is most likely due to diet.
Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils
2014-01-01
Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.
Koestel, Zoe L; Backus, Robert C; Tsuruta, Kaoru; Spollen, William G; Johnson, Sarah A; Javurek, Angela B; Ellersieck, Mark R; Wiedmeyer, Charles E; Kannan, Kurunthachalam; Xue, Jingchuan; Bivens, Nathan J; Givan, Scott A; Rosenfeld, Cheryl S
2017-02-01
Bisphenol A (BPA) is a widely present endocrine disruptor chemical found in many household items. Moreover, this chemical can bioaccumulate in various terrestrial and aquatic sources; thereby ensuring continual exposure of animals and humans. For most species, including humans, diet is considered the primary route of exposure. However, there has been little investigation whether commercial-brands of dog foods contain BPA and potential health ramifications of BPA-dietary exposure in dogs. We sought to determine BPA content within dog food, whether short-term consumption of these diets increases serum concentrations of BPA, and potential health consequences, as assessed by potential hematological, serum chemistry, cortisol, DNA methylation, and gut microbiome changes, in dogs associated with short-term dietary exposure to BPA. Fourteen healthy privately-owned dogs were used in this study. Blood and fecal samples were collected prior to dogs being placed for two-weeks on one of two diets (with one considered to be BPA-free), and blood and fecal samples were collected again. Serum/plasma samples were analyzed for chemistry and hematology profiles, cortisol concentrations, 5-methylcytosine in lymphocytes, and total BPA concentrations. Fecal samples were used for microbiome assessments. Both diets contained BPA, and after two-weeks of being on either diet, dogs had a significant increase in circulating BPA concentrations (pre-samples=0.7±0.15ng/mL, post-samples=2.2±0.15ng/mL, p<0.0001). Elevated BPA concentrations positively correlated with increased plasma bicarbonate concentrations and associated with fecal microbiome alterations. Short-term feeding of canned dog food increased circulating BPA concentrations in dogs comparable to amounts detected in humans, and greater BPA concentrations were associated with serum chemistry and microbiome changes. Dogs, who share our internal and external environments with us, are likely excellent indicators of potential human health concerns to BPA and other environmental chemicals. These findings may also have relevance to aquatic and terrestrial wildlife. Copyright © 2016 Elsevier B.V. All rights reserved.
Nassan, Feiby L; Chavarro, Jorge E; Mínguez-Alarcón, Lidia; Williams, Paige L; Tanrikut, Cigdem; Ford, Jennifer B; Dadd, Ramace; Perry, Melissa J; Hauser, Russ; Gaskins, Audrey J
2018-06-01
We examined associations of residential distance to major roadways, as a proxy for traffic-related air pollution exposures, with sperm characteristics and male reproductive hormones. The cohort included 797 men recruited from Massachusetts General Hospital Fertility Center between 2000 and 2015 to participate in fertility research studies. Men reported their residential addresses at enrollment and provided 1-6 semen samples and a blood sample during follow-up. We estimated the Euclidean distance to major roadways (e.g. interstates and highways: limited access highways, multi-lane highways (not limited access), other numbered routes, and major roads) using information from the Massachusetts Department of Geographic Information Systems. Semen parameters (1238 semen samples), sperm DNA integrity (389 semen samples), chromosomal disomy (101 semen samples), and serum reproductive hormones (405 serum samples) were assessed following standard procedures. Men in this cohort were primarily Caucasian (86%), not current smokers (92%), with a college or higher education (88%), and had an average age of 36 years and BMI of 27.7 kg/m 2 . The median (interquartile range) residential distance to a major roadway was 111 (37, 248) meters. Residential proximity to major roadways was not associated with semen parameters, sperm DNA integrity, chromosomal disomy, or serum reproductive hormone concentrations. The adjusted percent change (95% CI) in semen quality parameters associated with a 500 m increase in residential distance to a major roadway was -1.0% (-6.3, 4.5) for semen volume, 4.3% (-5.8, 15.7) for sperm concentration, 3.1% (-7.2, 14.5) for sperm count, 1.1% (-1.2, 3.4) for % total motile sperm, and 0.1% (-0.3, 0.5) for % morphologically normal sperm. Results were consistent when we modeled the semen parameters dichotomized according to WHO 2010 reference values. Residential distance to major roadways, as a proxy for traffic-related air pollution exposure, was not related to sperm characteristics or serum reproductive hormones among men attending a fertility clinic in Massachusetts. Copyright © 2018 Elsevier GmbH. All rights reserved.
Lindström, Mikael; Tohmola, Niina; Renkonen, Risto; Hämäläinen, Esa; Schalin-Jäntti, Camilla; Itkonen, Outi
2018-07-01
Serotonin (5-hydroxytyramine) is a mediator of gastrointestinal smooth muscle contraction, and is secreted by neuroendocrine neoplasms (NENs). We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum serotonin to be used in NEN diagnostics and follow-up. We used serum samples from healthy volunteers (n = 31) and patients suspected or monitored for NEN (n = 98). Serotonin-D 4 internal standard was added to samples before solid phase extraction (SPE) and quantification by LC-MS/MS. The effects of sample handling and preparation on serotonin stability were studied. Finally, we established a provisional reference range for serum serotonin and compared our assay with serum 5-hydroxyindoleacetic acid (5-HIAA) for detection of NENs. Our assay is sensitive and has a wide linear range (10-10,000 nmol/l). Serum serotonin is stable for 7 days at room temperature and for 3 months at -20 °C. Sampling temperature is not critical. Normal range for serum serotonin was 270-1490 nmol/l. We found that serum serotonin and 5-HIAA performed equally well as diagnostic tests for NENs. Our LC-MS/MS assay for serum serotonin is well suited for clinical research and patient diagnostics. Our results confirm that it can complement 5-HIAA in diagnosis of NENs. Copyright © 2018 Elsevier B.V. All rights reserved.
Massuger, L F; Thomas, C M; Segers, M F; Corstens, F H; Verheijen, R H; Kenemans, P; Poels, L G
1992-11-01
The development of human anti-mouse antibodies (HAMA) may cause problems in radioimmunotargeting studies, but may also improve survival of patients. To identify the presence of HAMA in blood samples from patients intravenously injected with 1 mg of 111In-labeled OV-TL3-F(ab')2, we developed three specific OV-TL 3-based HAMA assays and tested these along with two commercially available nonspecific HAMA assays (Sorin and Immunomedics). The specific assays were positive for HAMA with 10 postinjection serum samples from 7 patients. Eight of the 10 samples were also HAMA positive with one or both nonspecific HAMA assays. Conflicting results were observed with half the number of samples. The two nonspecific assays also reacted positively with another 11 serum samples from 5 patients including their preinjection samples. Despite some contradictory results, the nonspecific HAMA assays identify both pre-existent and Mab-induced HAMA, whereas the specific OV-TL3-based HAMA assays identify specific immune-responses occurring after the OV-TL 3 injection.
Henriksen, Louise T; Nersting, Jacob; Raja, Raheel A; Frandsen, Thomas L; Rosthøj, Steen; Schrøder, Henrik; Albertsen, Birgitte K
2014-07-01
L-asparaginase is an important drug in the treatment of childhood acute lymphoblastic leukaemia (ALL). Cerebrospinal fluid (CSF) asparagine depletion is considered a marker of asparaginase effect in the central nervous system (CNS) and may play a role in CNS-directed anti-leukaemia therapy. The objective of this study was to describe CSF asparagine depletion during 30 weeks of pegylated asparaginase therapy, 1000 iu/m(2) i.m. every second week, and to correlate CSF asparagine concentration with serum L-asparaginase enzyme activity. Danish children (1-17 years) with ALL, treated according to the Nordic Society of Paediatric Haematology and Oncology ALL2008 protocol, standard and intermediate risk, were included. CSF samples were obtained throughout L-asparaginase treatment at every scheduled lumbar puncture. A total of 128 samples from 31 patients were available for analysis. Median CSF asparagine concentration decreased from a pre-treatment level of 5·3 μmol/l to median levels ≤1·5 μmol/l. However, only 4/31 patients (five samples) had CSF asparagine concentrations below the limit of detection (0·1 μmol/l). In 11 patients, 24 paired same day serum and CSF samples were obtained. A decrease in CSF asparagine corresponded to serum enzyme activities above 50 iu/l. Higher serum enzyme activities were not followed by more extensive depletion. In conclusion, pegylated asparaginase 1000 iu/m(2) i.m. every second week effectively reduced CSF asparagine levels. © 2014 John Wiley & Sons Ltd.
Vaidya, Sunil R.; Dvivedi, Garima M.; Jadhav, Santoshkumar M.
2016-01-01
Background & objectives: The reports from the countries where mumps vaccine is given as routine immunization suggest differences in mumps virus neutralizing antibody titres when tested with vaccine and wild type viruses. Such reports are unavailable from countries like India where mumps vaccine is not included in routine immunization. We, therefore, undertook this study to understand the cross-neutralization activity of Indian mumps viruses. Methods: By using commercial mumps IgG enzyme immunoassay (EIA) and a rapid focus reduction neutralization test (FRNT), a panel of serum samples was tested. The panel consisted of 14 acute and 14 convalescent serum samples collected during a mumps outbreak and 18 archived serum samples. Two wild types (genotypes C and G) and Leningrad-Zagreb vaccine strain (genotype N) were used for the challenge experiments and FRNT titres were determined and further compared. The HN protein sequence of three mumps viruses was analyzed for the presence of key epitopes. Results: All serum samples effectively neutralized mumps virus wild types and a vaccine strain. However, significantly lower FRNT titres were noted to wild types than to vaccine strain (P<0.05). The comparison between EIA and FRNT results revealed 95.6 per cent agreement. No amino acid changes were seen in the epitopes in the Indian wild type strains. All potential N-linked glycosylation sites were observed in Indian strains. Interpretation & conclusions: Good cross-neutralization activity was observed for three mumps virus strains, however, higher level of FRNT titres was detected for mumps virus vaccine strain compared to Indian wild type isolates. PMID:26997012
ALLEMAN, Brandon W.; SMITH, Amanda R.; BYERS, Heather M.; BEDELL, Bruce; RYCKMAN, Kelli K.; MURRAY, Jeffrey C.; BOROWSKI, Kristi S.
2013-01-01
Objective To create a predictive model for preterm birth (PTB) from available clinical data and serum analytes. Study Design Serum analytes, routine pregnancy screening plus cholesterol and corresponding health information were linked to birth certificate data for a cohort of 2699 Iowa women with serum sampled in the first and second trimester. Stepwise logistic regression was used to select the best predictive model for PTB. Results Serum screening markers remained significant predictors of PTB even after controlling for maternal characteristics. The best predictive model included maternal characteristics, first trimester total cholesterol (TC), TC change between trimesters and second trimester alpha-fetoprotein and inhibin A. The model showed better discriminatory ability than PTB history alone and performed similarly in subgroups of women without past PTB. Conclusions Using clinical and serum screening data a potentially useful predictor of PTB was constructed. Validation and replication in other populations, and incorporation of other measures that identify PTB risk, like cervical length, can be a step towards identifying additional women who may benefit from new or currently available interventions. PMID:23500456
The validation of the Z-Scan technique for the determination of plasma glucose
NASA Astrophysics Data System (ADS)
Alves, Sarah I.; Silva, Elaine A. O.; Costa, Simone S.; Sonego, Denise R. N.; Hallack, Maira L.; Coppini, Ornela L.; Rowies, Fernanda; Azzalis, Ligia A.; Junqueira, Virginia B. C.; Pereira, Edimar C.; Rocha, Katya C.; Fonseca, Fernando L. A.
2013-11-01
Glucose is the main energy source for the human body. The concentration of blood glucose is regulated by several hormones including both antagonists: insulin and glucagon. The quantification of glucose in the blood is used for diagnosing metabolic disorders of carbohydrates, such as diabetes, idiopathic hypoglycemia and pancreatic diseases. Currently, the methodology used for this determination is the enzymatic colorimetric with spectrophotometric. This study aimed to validate the use of measurements of nonlinear optical properties of plasma glucose via the Z-Scan technique. For this we used samples of calibrator patterns that simulate commercial samples of patients (ELITech ©). Besides calibrators, serum glucose levels within acceptable reference values (normal control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) and also overestimated (pathological control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) were used in the methodology proposal. Calibrator dilutions were performed and determined by the Z-Scan technique for the preparation of calibration curve. In conclusion, Z-Scan method can be used to determinate glucose levels in biological samples with enzymatic colorimetric reaction and also to apply the same quality control parameters used in biochemistry clinical.
1976-01-01
Serum samples obtained from two groups within the College of Veterinary Medicine, Iowa State University, were examined for Toxoplasma gondii antibodies. Serum samples from 65 (26.0%) of the 250 persons examined yielded a titer of 1:16 or greater by the indirect fluorescent antibody test. A prevalence of 33.3% was obtained for 108 Veterinary Medical Research Institute (VMRI) personnel. Fof 142 veterinary students, the reactive rate was 20.4%. There was a marked difference of results within the student group--the reactive rate of 31.0% of 58 members of the class of 1975 was significantly higher (p less than 0.05) than the 13.1% for 84 members of the class of 1976. Studies on multiple serum samples were carried out on 55 VMRI personnel; 17 showed a change in serologic reactivity but only 5 had titers of 1:64 or greater. No definitive relationships could be determined between the epidemiologic characteristics examined and the presence of T. gondii antibodies. Characteristics examined included age, sex, primary residency, food habits (eating of rare beef and smoked pork products), and extent of animal contact. Images p526-a PMID:825918
Hyperuricemia in the inhabitants of the Marshall Islands
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, W.H.; Harper, J.A.; Heotis, P.M.
1984-06-01
Annual medical examinations are conducted by Brookhaven National Laboratory (BNL) for a population of Marshallese who were accidentally exposed to radioactive fallout in 1954, for a comparison population, and for all inhabitants of the atolls of Rongelap and Utirik. Disease surveillance includes analysis of serum samples. Elevated serum uric acid (SUA) levels are common along Pacific populations, and modifying environmental factors have been investigated as a cause for this finding. The authors have studied SUA levels of people living in the Marshall Islands, and have found elevated values similar to those reported for other Micronesian populations. The nearly Gaussian distributionmore » of individual serum uric acid values for men, and for women less than or equal to45 years of age, indicates that the elevation is due to a regularized increase in serum uric acid rather than to a subpopulation that has pathologic hyperuricemia. The higher serum uric acid levels appear, therefore, to be normal for the Marshallese, a conclusion supported by the infrequency of clinical gout in the population tested.« less
First Trimester Maternal Serum PP13 in the Risk Assessment for Preeclampsia
ROMERO, Roberto; KUSANOVIC, Juan Pedro; THAN, Nandor Gabor; EREZ, Offer; GOTSCH, Francesca; ESPINOZA, Jimmy; EDWIN, Samuel; CHEFETZ, Ilana; GOMEZ, Ricardo; NIEN, Jyh Kae; SAMMAR, Marei; PINELES, Beth; HASSAN, Sonia S.; MEIRI, Hamutal; TAL, Yossi; KUHNREICH, Ido; PAPP, Zoltan; CUCKLE, Howard S.
2008-01-01
Objective To determine whether first trimester maternal serum Placental Protein 13 (PP13) concentrations can be used in the risk assessment for preeclampsia. Study Design This case-control study included 50 patients with preeclampsia and 250 patients with normal pregnancies. Samples were collected between 8-13 weeks of gestation. Serum PP13 concentrations were measured by ELISA and expressed as medians and multiples of the median (MoM) for gestational age. Sensitivity and specificity were derived from receiver operating characteristic curve analysis. Results 1) Serum PP13 concentration in the first trimester was significantly lower in patients who developed preterm and early-onset preeclampsia than in those with normal pregnancies; and 2) At 80% specificity, a cutoff of 0.39 MoM had a sensitivity of 100% for early-onset preeclampsia and 85% for preterm preeclampsia. Conclusion Maternal serum first trimester PP13 appears to be a reasonable marker for risk assessment, but a weak marker for severe preeclampsia at term, and ineffective for identifying mild preeclampsia at term. PMID:18539259
Metabonomics identifies serum metabolite markers of colorectal cancer.
Tan, Binbin; Qiu, Yunping; Zou, Xia; Chen, Tianlu; Xie, Guoxiang; Cheng, Yu; Dong, Taotao; Zhao, Linjing; Feng, Bo; Hu, Xiaofang; Xu, Lisa X; Zhao, Aihua; Zhang, Menghui; Cai, Guoxiang; Cai, Sanjun; Zhou, Zhanxiang; Zheng, Minhua; Zhang, Yan; Jia, Wei
2013-06-07
Recent studies suggest that biofluid-based metabonomics may identify metabolite markers promising for colorectal cancer (CRC) diagnosis. We report here a follow-up replication study, after a previous CRC metabonomics study, aiming to identify a distinct serum metabolic signature of CRC with diagnostic potential. Serum metabolites from newly diagnosed CRC patients (N = 101) and healthy subjects (N = 102) were profiled using gas chromatography time-of-flight mass spectrometry (GC-TOFMS) and ultraperformance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-QTOFMS). Differential metabolites were identified with statistical tests of orthogonal partial least-squares-discriminant analysis (VIP > 1) and the Mann-Whitney U test (p < 0.05). With a total of 249 annotated serum metabolites, we were able to differentiate CRC patients from the healthy controls using an orthogonal partial least-squares-discriminant analysis (OPLS-DA) in a learning sample set of 62 CRC patients and 62 matched healthy controls. This established model was able to correctly assign the rest of the samples to the CRC or control groups in a validation set of 39 CRC patients and 40 healthy controls. Consistent with our findings from the previous study, we observed a distinct metabolic signature in CRC patients including tricarboxylic acid (TCA) cycle, urea cycle, glutamine, fatty acids, and gut flora metabolism. Our results demonstrated that a panel of serum metabolite markers is of great potential as a noninvasive diagnostic method for the detection of CRC.
McBride, David; Lovelock, Kirsten; Shepherd, Daniel; Dirks, Kim; Welch, David; Gray, Andrew
2016-10-01
The New Zealand Ministry of Health responded to community concern about dioxin exposure during on-site remediation of a pesticide-contaminated rural area by commissioning this exposed-referent study of serum dioxins and health in local residents. All 200 residents were eligible, with age and sex matching to demographically comparable referents. Face-to-face interviews included questions on health status, health-related quality of life (HRQOL) and perceptions about community consultation. Thirty serum samples were obtained, eligibility being based on likelihood of exposure and age. Both HRQOL and serum outcomes were analysed by the appropriate regression methods. Of 200 eligible residents, 139 (69.5%) participated, with 139 matched referents. Mapua residents had lower physical and psychological HRQOL scores, but no difference in health status. 2,3,7,8 TCDD was below the limit of detection in the majority of all serum samples, with some congeners being higher in referents. Perceptions of the communication process were equivocal. Both dioxin levels and measures of health did not differ significantly between the exposed community and controls. Implications for public health: The results suggest neither significant dioxin exposure nor community health effects. Oversight by expert panel with health expertise, allied to sound communication, may have helped the community understand the risks. © 2016 Public Health Association of Australia.
Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana
2014-01-01
Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.
Quantitative bioanalysis of strontium in human serum by inductively coupled plasma-mass spectrometry
Somarouthu, Srikanth; Ohh, Jayoung; Shaked, Jonathan; Cunico, Robert L; Yakatan, Gerald; Corritori, Suzana; Tami, Joe; Foehr, Erik D
2015-01-01
Aim: A bioanalytical method using inductively-coupled plasma-mass spectrometry to measure endogenous levels of strontium in human serum was developed and validated. Results & methodology: This article details the experimental procedures used for the method development and validation thus demonstrating the application of the inductively-coupled plasma-mass spectrometry method for quantification of strontium in human serum samples. The assay was validated for specificity, linearity, accuracy, precision, recovery and stability. Significant endogenous levels of strontium are present in human serum samples ranging from 19 to 96 ng/ml with a mean of 34.6 ± 15.2 ng/ml (SD). Discussion & conclusion: Calibration procedures and sample pretreatment were simplified for high throughput analysis. The validation demonstrates that the method was sensitive, selective for quantification of strontium (88Sr) and is suitable for routine clinical testing of strontium in human serum samples. PMID:28031925
Serum fructosamine concentrations in 59 dogs naturally Infected with Angiostrongylus vasorum.
Willesen, J L; Jensen, A L; Kristensen, A T; Kjelgaard-Hansen, M; Jessen, R; Koch, J
2006-06-01
Retrospectively, 89 cases of dogs infected with Angiostrongylus vasorum were examined. Fifty-nine of these 89 dogs fulfilled the criteria of not being dually infected with Crenosoma vulpis as well as having a full biochemistry profile including serum fructosamine available. The mean serum fructosamine value of the 59 dogs was 236 micromol/l (reference value 258-348 micromol/l) and significantly lower than the serum fructosamine level of 314 micromol/l in a control group of 42 clinically healthy dogs. Eleven dogs were available for follow up after successful treatment of angiostrongylosis. In this group, the serum fructosamine value rose from a mean of 244 micromol/l to a mean of 320 micromol/l following treatment. Serum glucose, albumin and protein were all within the respective reference ranges at all sampling points. The results indicate that serum fructosamine could be affected by infection with A. vasorum. Furthermore, this change cannot be explained by measurable changes in the level of glucose, albumin or protein. The clinical impact of this study is that a low fructosamine value may indicate infection with A. vasorum thereby suggesting a Baermann test to be performed.
[Value of polymerase chain reaction in serum for the diagnosis of enteroviral meningitis].
Marque Juillet, S; Lion, M; Pilmis, B; Tomini, E; Dommergues, M-A; Laporte, S; Foucaud, P
2013-06-01
Enteroviruses (EV) are a common cause of aseptic meningitis in children. Virological diagnosis of EV meningitis is currently based on the detection of the viral genome in the cerebrospinal fluid (CSF). This study attempted to determine the correlation and the temporality of the polymerase chain reaction (PCR) assay in serum and CSF and to evaluate the possibility of diagnosing EV infection only on the serum PCR. The EV genome was sought by RT real-time PCR (Smart Cycler EV Primer and Probe Set(®), Cepheid) in CSF and serum, collected at the same time, for all children who underwent a lumbar puncture for suspected meningitis, between 1 June and 31 July 2010 at the Versailles Hospital. Forty-four patients were included in the study. EV infection was documented for 22 of them. In 10 patients, the EV genome was detected in CSF only; in 3 patients in serum only, and in 9 patients in both. Among patients with acute EV neurological infection, viremic children were significantly younger (1.6 months versus 5.8 years; P<0.001). Viremia was detected when the serum was sampled within 30 h after the beginning of symptoms. These results confirm previous reports of early and transient viremia in young children. This preliminary study shows the limits and added value of EV PCR in serum. It suggests that in some children and under certain conditions (age >3 months, clinical and biological compatibility with a viral infection, no previous antibiotic therapy, time from symptom onset to blood sampling <30 h, PCR in serum analyzed within 3h), PCR in serum, when positive, is a possible alternative. Therefore, it may be possible to diagnose EV infection without performing a lumbar puncture in a limited number of young children (11.4% of our suspected cases). This study needs to be reinforced by a multicenter study with a broader panel of patients. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Eipeldauer, Stefan; Thomas, Anita; Hoechtl-Lee, Leonard; Kecht, Mathias; Binder, Harald; Koettstorfer, Julia; Gregori, Markus; Sarahrudi, Kambiz
2014-01-01
Sonic Hedgehog (SHH) is a new signalling pathway in bone repair. Evidence exist that SHH pathway plays a significant role in vasculogenesis and limb development during embryogenesis. Some in vitro and animal studies has already proven its potential for bone regeneration. However, no data on the role of SHH in the human fracture healing have been published so far. Seventy-five patients with long bone fractures were included into the study and divided in 2 groups. First group contained 69 patients with normal fracture healing. Four patients with impaired fracture healing formed the second group. 34 volunteers donated blood samples as control. Serum samples were collected over a period of 1 year following a standardized time schedule. In addition, SHH levels were measured in fracture haematoma and serum of 16 patients with bone fractures. Fracture haematoma and patients serum both contained lower SHH concentrations compared to control serum. The comparison between the patients' serum SHH level and the control serum revealed lower levels for the patients at all measurement time points. Significantly lower concentrations were observed at weeks 1 and 2 after fracture. SHH levels were slightly decreased in patients with impaired fracture healing without statistical significance. This is the first study to report local and systemic concentration of SHH in human fracture healing and SHH serum levels in healthy adults. A significant reduction of the SHH levels during the inflammatory phase of fracture healing was found. SHH concentrations in fracture haematoma and serum were lower than the concentration in control serum for the rest of the healing period. Our findings indicate that there is no relevant involvement of SHH in human fracture healing. Fracture repair process seem to reduce the SHH level in human. Further studies are definitely needed to clarify the underlying mechanisms.
Feasibility study of feces for noninvasive biomonitoring of brominated flame retardants in toddlers.
Sahlström, Leena M O; Sellström, Ulla; de Wit, Cynthia A; Lignell, Sanna; Darnerud, Per Ola
2015-01-06
This study investigated the feasibility of using feces as a noninvasive matrix to estimate serum concentrations of brominated flame retardants (BFRs) in toddlers for biomonitoring purposes. Tri- to decabrominated diphenyl ethers (tri-decaBDEs), isomer-specific hexabromocyclododecanes, and 16 emerging BFRs were determined in feces from 22 toddlers (11-15 months of age), and results were compared to previously analyzed matched serum samples. BDE-47, -153, -196, -197, -203, -206, -207, -208, and -209 were detected in the feces creating a matched data set (feces-serum, n = 21). Tetra-octaBDE concentrations were significantly higher (Student's paired comparisons t test, α = 0.05) in serum versus feces with BDE-153 having the highest mean difference between the sample matrices. BDE-209 was found in significantly higher concentrations in feces compared to serum. Significant correlations (Pearson's, α = 0.05) between congener-specific concentrations in feces and serum were found for all BDEs except BDE-197 and -203. The feces-serum associations found can be used to estimate serum concentrations of tetra-decaBDEs from feces concentrations and enable a noninvasive sampling method for biomonitoring BDEs in toddlers.
Panyasing, Yaowalak; Kedkovid, Roongtham; Thanawongnuwech, Roongroje; Kittawornrat, Apisit; Ji, Ju; Giménez-Lirola, Luis; Zimmerman, Jeffrey
2018-03-01
Early recognition and rapid elimination of infected animals is key to controlling incursions of classical swine fever virus (CSFV). In this study, the diagnostic characteristics of 10 CSFV assays were evaluated using individual serum (n = 601) and/or oral fluid (n = 1417) samples collected from -14 to 28 days post inoculation (DPI). Serum samples were assayed by virus isolation (VI), 2 commercial antigen-capture enzyme-linked immunosorbent assays (ELISA), virus neutralization (VN), and 3 antibody ELISAs. Both serum and oral fluid samples were tested with 3 commercial real-time reverse transcription-polymerase chain reaction (rRT-PCR) assays. One or more serum samples was positive by VI from DPIs 3 to 21 and by antigen-capture ELISAs from DPIs 6 to 17. VN-positive serum samples were observed at DPIs ≥ 7 and by antibody ELISAs at DPIs ≥ 10. CSFV RNA was detected in serum samples from DPIs 2 to 28 and in oral fluid samples from DPIs 4 to 28. Significant differences in assay performance were detected, but most importantly, no single combination of sample and assay was able to dependably identify CSFV-inoculated pigs throughout the 4-week course of the study. The results show that effective surveillance for CSFV, especially low virulence strains, will require the use of PCR-based assays for the detection of early infections (<14 days) and antibody-based assays, thereafter. Copyright © 2018 Elsevier B.V. All rights reserved.
Nyberg, G; Mårtensson, E
1986-01-01
The effects were tested of eight common types of blood collection tubes and two types of "plasma separators" on the stability of the tricyclic antidepressants amitriptyline, imipramine, clomipramine, and their monodemethylated metabolites in venous blood samples. Although EDTA-containing Venoject lavender and Vacutainer lavender tubes seemed to give the most stable plasma samples, and Venoject red the most stable serum samples, the differences were too small to have practical consequences. Vacutainer royal blue collection tubes gave significant losses of greater than 20% of some of the substances. The tubes with serum separator gel or filter proved unsuitable, since they were responsible for losses of greater than 40%. The losses were not caused by redistribution between blood cells and plasma but occurred mainly as a result of contact between the contents and the caps of the tubes. Experiments with freezing, thawing, and storage of samples showed that freshly sampled blood could be stored at room temperature for 24 h in Venoject green tubes without significant losses. Serum samples could be stored at refrigerator temperature for 4 weeks without important losses. Freezing, thawing, and storage at -20 degrees C did not influence the serum or plasma concentrations.
Kirino, Yohei; Kawaguchi, Yasushi; Tada, Yoshifumi; Tsukamoto, Hiroshi; Ota, Toshiyuki; Iwamoto, Masahiro; Takahashi, Hiroki; Nagasawa, Kohei; Takei, Shuji; Horiuchi, Takahiko; Ichida, Hisae; Minota, Seiji; Ueda, Atsuhisa; Ohta, Akihide; Ishigatsubo, Yoshiaki
2018-01-11
Heme oxygenase (HO)-1 is a heme-degrading enzyme highly expressed in monocyte/macrophage, serum levels of which may be promising biomarker for adult-onset Still's disease (AOSD). We here report data on the use of serum ferritin and HO-1 levels in AOSD. Under the Hypercytokinemia Study Group collaboration, we collected sera from a total of 145 AOSD patients. Three independent experts judged whether the patients were definite AOSD depending on the clinical information. These 91 'definite AOSD' patients were further divided into active, remission, and relapse groups. Forty-six cases of systemic vasculitis, sepsis, etc. were included as disease controls. Serum ferritin and HO-1 levels were measured using ELISA. Associations between clinical symptoms, serum ferritin, and HO-1 were explored. Multivariate regression analysis was performed to identify independent variables associated with definite AOSD diagnosis. Serum ferritin and HO-1 levels were significantly higher in active and relapsed AOSD cases compared to disease controls, and were reduced by the treatment. Although a significant correlation was found between serum ferritin and HO-1 levels, a discrepancy was found in some cases such as iron-deficiency anemia. Receiver operating characteristic analysis identified optimal levels of serum ferritin (>819 ng/ml; sensitivity 76.1% and specificity 73.8%), and serum HO-1 (>30.2 ng/ml; sensitivity 84.8% and specificity 83.3%) that differentiated AOSD from controls. Interestingly, 88.9% of patients with AOSD who relapsed exceeded the cut-off value of serum HO-1 > 30.2 ng/ml, but only 50.0% exceeded serum ferritin >819 ng/ml (p = .013), suggesting that serum HO-1 levels may be a convenient indicator of AOSD disease status. Multivariate analysis identified neutrophilia, RF/ANA negativity, sore throat, and elevated serum HO-1 as independent variables associated with AOSD diagnosis. We confirmed that serum ferritin and HO-1 serve as highly specific and sensitive biomarkers for AOSD. A future prospective study with large sample size is necessary to determine whether these biomarkers could be included in Yamaguchi's Criteria.
Zhang, Xiaolan; Li, Xiaojing; Jing, Ye; Fang, Xiangming; Zhang, Xinyu; Lei, Bingli; Yu, Yingxin
2017-03-01
Prenatal exposure to polycyclic aromatic hydrocarbons (PAHs) is a high-priority public health concern. However, maternal to fetal transplacental transfer of PAHs has not been systematically studied. To investigate the transplacental transfer of PAHs from mother to fetus and determine the influence of lipophilicity (octanol-water partition coefficient, K OW ) on transfer process, in the present study, we measured the concentrations of 15 PAHs in 95 paired maternal and umbilical cord serum, and placenta samples (in total 285 samples) collected in Shanghai, China. The average concentration of total PAHs was the highest in maternal serums (1290 ng g -1 lipid), followed by umbilical cord serums (1150 ng g -1 lipid). The value was the lowest in placenta samples (673 ng g -1 lipid). Low molecular weight PAHs were the predominant compounds in the three matrices. Increases in fish and meat consumption did not lead to increases in maternal PAH levels, and no obvious gender differences in umbilical cord serums were observed. The widespread presence of PAHs in umbilical cord serums indicated the occurrence of transplacental transfer. The ratios of PAH concentrations in umbilical cord serum to those in maternal serum (F/M) and the concentrations in placenta to those in maternal serum (P/M) of paired samples were analyzed to characterize the transfer process of individual PAHs. Most F/M ratios on lipid basis were close to one (range: 0.79 to 1.36), which suggested that passive diffusion may control the transplacental transfer of PAHs from maternal serum to the fetal circulation. The P/M and F/M values calculated on lipid basis showed that PAHs with lower K OW were more likely to transfer from mother to fetus via the placenta. Copyright © 2016 Elsevier Ltd. All rights reserved.
Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.
2003-01-01
OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429
Ali, Nadeem; Malik, Riffat Naseem; Mehdi, Toufeer; Eqani, Syed Ali Musstjab Akber Shah; Javeed, Aqeel; Neels, Hugo; Covaci, Adrian
2013-04-01
Concentrations of different classes of organohalogenated contaminants (OHCs) viz., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), bromophenols (BPs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and their metabolites were determined in cat and dog serum and hair samples from Pakistan. The major DDT metabolite, p,p'-DDE, was the major OHC in cat serum (N=20) and ranged between 1 and 2150 ng/g lipid weight (lw). p,p'-DDE was not detected in dog serum (N=16). In contrary to other OHCs, levels of ∑HO-PCBs were significantly higher in dog serum (median=6.0 ng/g lw) than cat serum (median=2.2 ng/g lw). Levels of most OHCs were significantly higher (p<0.05) in cat serum than those found in human serum from the same region, in particular for ∑PBDEs (ranged 1-1280 ng/g lw). Significantly lower levels of OCPs (p<0.05) were detected in dog serum than in human serum. The concentrations of ∑BPs were seven times higher in cat serum (median 112 ng/g lw) than dog serum (median 16 ng/g lw). To the best of our knowledge, this is the first time that NBFRs, e.g. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), decabromodiphenylethane (DBDPE), and bis(2-ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), were detected in cat and dog's hair. BTBPE had the highest detection frequency (30%) in the serum samples. In cat and dog hair samples, the order of importance of OHCs was ∑OCPs>∑NBFRs>∑PBDEs>∑PCB, with the highest concentrations being around 38 ng/g hair. In paired hair-serum cat samples (N=12), ∑DDTs (r=0.65, p=0.001) were significantly correlated, while for all other OHCs no significant correlations (p<0.001) were observed in both cats and dogs. Our findings on both hair and serum samples suggested that pet dogs do not bioaccumulate DDTs. Our results are also in agreement with the hypothesis that pets may serve as biosentinels for indoor pollution. This is the first study to document the presence of OHCs in pets from Pakistan and provides baseline information for future monitoring of OHCs in pets. Copyright © 2013 Elsevier B.V. All rights reserved.
Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio
2012-01-01
Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296
Kooshki, A; Samadipour, E; Akbarzadeh, R
2015-01-01
Background:Despite the high levels of inflammation in hemodialysis patients and the effects of diet on systemic inflammation, such as the development of atherosclerosis and cardiovascular disease, few studies have evaluated the relationship of macronutrients and antioxidants intake with serum C-reactive protein (CRP). Therefore, this study assessed the relationship between serum high sensitivity CRP (hs-CRP) with macronutrients and antioxidants intake and serum albumin. Methods:This cross-sectional study used census sampling to select 75 hemodialysis patients (35 men and 40 women) who attended the hemodialysis department of Vaseie Hospital of Sabzevar, Iran. After obtaining the written consent, all the patients were interviewed and dietary data was collected by using a semi-quantitative food frequency questionnaire including 160 food items. Diet analysis was performed with Nutritionist IV. Before being connected to the dialysis machine, 5 cc fasting blood samples were obtained from all participants and serum hs-CRP and albumin levels were measured. All the statistical analyses were conducted with SPSS -for Windows, version 16.0. Results:The patients’ mean body mass index was 20.09 ± 3.27 kg/ m2. The participants’ intake of antioxidants and all macronutrients, except for carbohydrates and proteins, was less than the standard levels. Moreover, the hs-CRP had significant inverse relationships with serum albumin (P=0.0001) and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy (P=0.002) and protein (P=0.0001). Conclusion:Our findings indicated hs-CRP levels of hemodialysis patients to have significant inverse relationships with serum albumin and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy and protein. PMID:28255396
Kooshki, A; Samadipour, E; Akbarzadeh, R
2015-01-01
Background: Despite the high levels of inflammation in hemodialysis patients and the effects of diet on systemic inflammation, such as the development of atherosclerosis and cardiovascular disease, few studies have evaluated the relationship of macronutrients and antioxidants intake with serum C-reactive protein (CRP). Therefore, this study assessed the relationship between serum high sensitivity CRP (hs-CRP) with macronutrients and antioxidants intake and serum albumin. Methods: This cross-sectional study used census sampling to select 75 hemodialysis patients (35 men and 40 women) who attended the hemodialysis department of Vaseie Hospital of Sabzevar, Iran. After obtaining the written consent, all the patients were interviewed and dietary data was collected by using a semi-quantitative food frequency questionnaire including 160 food items. Diet analysis was performed with Nutritionist IV. Before being connected to the dialysis machine, 5 cc fasting blood samples were obtained from all participants and serum hs-CRP and albumin levels were measured. All the statistical analyses were conducted with SPSS -for Windows, version 16.0. Results: The patients' mean body mass index was 20.09 ± 3.27 kg/ m2. The participants' intake of antioxidants and all macronutrients, except for carbohydrates and proteins, was less than the standard levels. Moreover, the hs-CRP had significant inverse relationships with serum albumin (P=0.0001) and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy (P=0.002) and protein (P=0.0001). Conclusion: Our findings indicated hs-CRP levels of hemodialysis patients to have significant inverse relationships with serum albumin and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy and protein.
Serum glycerophosphate levels are increased in Japanese men with type 2 diabetes.
Daimon, Makoto; Soga, Tomoyoshi; Hozawa, Atsushi; Oizumi, Toshihide; Kaino, Wataru; Takase, Kaoru; Karasawa, Shigeru; Jimbu, Yumi; Wada, Kiriko; Kameda, Wataru; Susa, Shinji; Kayama, Takamasa; Saito, Kaori; Tomita, Masaru; Kato, Takeo
2012-01-01
To identify metabolites showing changes in serum levels among Japanese male with diabetes. We performed metabolite profiling by coupling capillary electrophoresis with electrospray ionization time-of-flight mass spectrometry using fasting serum samples from Japanese male subjects with diabetes (n=17), impaired glucose tolerance (IGT; n=5) and normal glucose tolerance (NGT; n=14). Other than the expected differences in characteristics related to abnormal glucose metabolism, the percent body fat was significantly different among subjects with diabetes, IGT and NGT (27.3±6.2, 22.2±4.5 and 19.2±6.0%, respectively, p=0.0022). Therefore, percent body fat was considered as a possible confounding factor in subsequent analyses. Of 560 metabolites detected using our platform, the levels of 74 metabolites were quantified in all of the serum samples. Significant differences between diabetes and NGT were observed for 24 metabolites. The top-ranked metabolite was glycerol-3-phophate (glycerophosphate), which was significantly higher in subjects with diabetes than in those with NGT, even after Bonferroni correction for multiple testing (11.7±3.6 vs. 6.4±1.9 µM, respectively; corrected p=0.0222). Stepwise multiple regression analyses revealed that serum glycerophosphate levels were significantly correlated with 2-h plasma glucose after a 75-g oral glucose tolerance test (r=0.553, p=0.0005), independently of other characteristics, including FPG and HbA1c. Serum glycerophosphate levels were found to be elevated in Japanese men with diabetes, and correlated with 2-h PG, independent of FPG and HbA1c. Namely, serum glycerophosphate level at fasting condition can be a marker for predicting glucose intolerance. These results warrant further studies to evaluate the relevance of glycerophosphate in the pathophysiology of diabetes.
Pilot Metabolome-Wide Association Study of Benzo(a)pyrene in Serum from Military Personnel
Walker, Douglas I.; Pennell, Kurt D.; Uppal, Karan; Xia, Xiaoyan; Hopke, Philip K.; Utell, Mark J.; Phipps, Richard P.; Sime, Patricia J.; Rohrbeck, Patricia; Mallon, COL Timothy M.; Jones, Dean P.
2016-01-01
Objective A pilot study was conducted to test the feasibility of using Department of Defense Serum Repository (DoDSR) samples to study health and exposure-related effects. Methods Thirty unidentified human serum samples were obtained from the DoDSR and analyzed for normal serum metabolites with high-resolution mass spectrometry and serum levels of free benzo(a)pyrene (BaP) by gas chromatography-mass spectrometry. Metabolic associations with BaP were determined using a metabolome wide association study (MWAS) and metabolic pathway enrichment. Results The serum analysis detected normal ranges of glucose, selected amino acids, fatty acids, and creatinine. Free BaP was detected in a broad concentration range. MWAS of BaP showed associations with lipids, fatty acids, and sulfur amino acid metabolic pathways. Conclusion The results show the DoDSR samples are of sufficient quality for chemical profiling of DoD personnel. PMID:27501104
Pilot Metabolome-Wide Association Study of Benzo(a)pyrene in Serum From Military Personnel.
Walker, Douglas I; Pennell, Kurt D; Uppal, Karan; Xia, Xiaoyan; Hopke, Philip K; Utell, Mark J; Phipps, Richard P; Sime, Patricia J; Rohrbeck, Patricia; Mallon, Col Timothy M; Jones, Dean P
2016-08-01
A pilot study was conducted to test the feasibility of using Department of Defense Serum Repository (DoDSR) samples to study health and exposure-related effects. Thirty unidentified human serum samples were obtained from the DoDSR and analyzed for normal serum metabolites with high-resolution mass spectrometry and serum levels of free benzo(a)pyrene (BaP) by gas chromatography-mass spectrometry. Metabolic associations with BaP were determined using a metabolome-wide association study (MWAS) and metabolic pathway enrichment. The serum analysis detected normal ranges of glucose, selected amino acids, fatty acids, and creatinine. Free BaP was detected in a broad concentration range. MWAS of BaP showed associations with lipids, fatty acids, and sulfur amino acid metabolic pathways. The results show that the DoDSR samples are of sufficient quality for chemical profiling of DoD personnel.
Romaniuk, Wioletta; Kalita, Joanna; Ostrowska, Halina; Kloczko, Janusz
2018-03-05
The ubiquitin-proteasome system is relevant in the pathobiology of many haematological malignancies, including multiple myeloma. The assessment of proteasome concentration and chymotrypsin-like (ChT-L) activity might constitute a new approach to diagnosis, prognosis and monitoring of anticancer treatment of patients with haematological malignancies and other diseases. The aim of our study was to determine which material, plasma or serum, is better for measuring chymotrypsin-like (ChT-L) activity and proteasome concentration. We analysed proteasome concentration and chymotrypsin-like (ChT-L) activity in 70 plasma and serum samples drawn from 28 patients at different treatment stages for multiple myeloma (MM) and 31 healthy volunteers. Proteasome ChT-L activity and concentration in multiple myeloma patients were significantly higher in plasma compared to serum. In this group we observed significant and positive correlations both between the plasma and serum proteasome ChT-L activity and plasma and serum proteasome concentration. The higher values of proteasome concentration and ChT-L activity in plasma than in serum and their better correlations with parameters of tumour load and prognosis suggest that plasma constitutes a better biological material for measuring ChT-L activity and proteasome concentration than serum in multiple myeloma patients.
Genome-wide association study identifies multiple loci influencing human serum metabolite levels
Kettunen, Johannes; Tukiainen, Taru; Sarin, Antti-Pekka; Ortega-Alonso, Alfredo; Tikkanen, Emmi; Lyytikäinen, Leo-Pekka; Kangas, Antti J; Soininen, Pasi; Würtz, Peter; Silander, Kaisa; Dick, Danielle M; Rose, Richard J; Savolainen, Markku J; Viikari, Jorma; Kähönen, Mika; Lehtimäki, Terho; Pietiläinen, Kirsi H; Inouye, Michael; McCarthy, Mark I; Jula, Antti; Eriksson, Johan; Raitakari, Olli T; Salomaa, Veikko; Kaprio, Jaakko; Järvelin, Marjo-Riitta; Peltonen, Leena; Perola, Markus; Freimer, Nelson B; Ala-Korpela, Mika; Palotie, Aarno; Ripatti, Samuli
2013-01-01
Nuclear magnetic resonance assays allow for measurement of a wide range of metabolic phenotypes. We report here the results of a GWAS on 8,330 Finnish individuals genotyped and imputed at 7.7 million SNPs for a range of 216 serum metabolic phenotypes assessed by NMR of serum samples. We identified significant associations (P < 2.31 × 10−10) at 31 loci, including 11 for which there have not been previous reports of associations to a metabolic trait or disorder. Analyses of Finnish twin pairs suggested that the metabolic measures reported here show higher heritability than comparable conventional metabolic phenotypes. In accordance with our expectations, SNPs at the 31 loci associated with individual metabolites account for a greater proportion of the genetic component of trait variance (up to 40%) than is typically observed for conventional serum metabolic phenotypes. The identification of such associations may provide substantial insight into cardiometabolic disorders. PMID:22286219
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crow, J. Allen; Borazjani, Abdolsamad; Potter, Philip M.
2007-05-15
Hydrolytic metabolism of pyrethroid insecticides in humans is one of the major catabolic pathways that clear these compounds from the body. Rodent models are often used to determine the disposition and clearance rates of these esterified compounds. In this study the distribution and activities of esterases that catalyze pyrethroid metabolism have been investigated in vitro using several human and rat tissues, including small intestine, liver and serum. The major esterase in human intestine is carboxylesterase 2 (hCE2). We found that the pyrethroid trans-permethrin is effectively hydrolyzed by a sample of pooled human intestinal microsomes (5 individuals), while deltamethrin and bioresmethrinmore » are not. This result correlates well with the substrate specificity of recombinant hCE2 enzyme. In contrast, a sample of pooled rat intestinal microsomes (5 animals) hydrolyze trans-permethrin 4.5-fold slower than the sample of human intestinal microsomes. Furthermore, it is demonstrated that pooled samples of cytosol from human or rat liver are {approx} 2-fold less hydrolytically active (normalized per mg protein) than the corresponding microsomal fraction toward pyrethroid substrates; however, the cytosolic fractions do have significant amounts ({approx} 40%) of the total esteratic activity. Moreover, a 6-fold interindividual variation in carboxylesterase 1 protein expression in human hepatic cytosols was observed. Human serum was shown to lack pyrethroid hydrolytic activity, but rat serum has hydrolytic activity that is attributed to a single CE isozyme. We purified the serum CE enzyme to homogeneity to determine its contribution to pyrethroid metabolism in the rat. Both trans-permethrin and bioresmethrin were effectively cleaved by this serum CE, but deltamethrin, esfenvalerate, alpha-cypermethrin and cis-permethrin were slowly hydrolyzed. Lastly, two model lipase enzymes were examined for their ability to hydrolyze pyrethroids. However, no hydrolysis products could be detected. Together, these results demonstrate that extrahepatic esterolytic metabolism of specific pyrethroids may be significant. Moreover, hepatic cytosolic and microsomal hydrolytic metabolism should each be considered during the development of pharmacokinetic models that predict the disposition of pyrethroids and other esterified compounds.« less
Mimivirus Circulation among Wild and Domestic Mammals, Amazon Region, Brazil
Dornas, Fábio P.; Rodrigues, Felipe P.; Boratto, Paulo V.M.; Silva, Lorena C.F.; Ferreira, Paulo C.P.; Bonjardim, Cláudio A.; Trindade, Giliane S.; Kroon, Erna G.; La Scola, Bernard
2014-01-01
To investigate circulation of mimiviruses in the Amazon Region of Brazil, we surveyed 513 serum samples from domestic and wild mammals. Neutralizing antibodies were detected in 15 sample pools, and mimivirus DNA was detected in 9 pools of serum from capuchin monkeys and in 16 pools of serum from cattle. PMID:24564967
Sahoo, S.; Raghavendra, K. M.; Biswas, S.
2014-01-01
Moringa oleifera Lam. has been an important plant in the history of mankind, both for its nutritional and medicinal uses. Apart from bactericidal effects, the parts of this plant have been effectively used in the treatment of circulatory, respiratory, endocrine, digestive as well as neural disorders. Till date, though, there has been no reported activity of the involvement of any proteinaceous extract from M. oleifera on high levels of serum creatinine. To address this issue, blood samples with high levels of serum creatinine (2 mg/dl and above) were treated with leaf extract from M. oleifera. The crude extract was partially purified initially and eventually purified to completion as well. All these proteinaceous fractions were used to treat samples with high levels of serum creatinine as mentioned above. While the treatment of serum sample having high creatinine with crude extract and partially purified protein fractions showed a decrease of approximately 20% in the levels of serum creatinine over a period of 24 h, the samples treated with purified protein fraction reduced the serum creatinine level by 50%. In light of the fact that increased level of serum creatinine levels have adverse downstream effects on the heart, lungs and other organs, this communication assumes significance because it suggests a way of reducing the level of serum creatinine as an emergency measure. Further, the identification and characterisation of this proteinaceous component and possible in vivo experiments would provide a major tool for the treatment of downstream complications associated with increased serum creatinine via a new sources, albeit a natural one. PMID:24799742
Chantada-Vázquez, María Pilar; Moreda-Piñeiro, Jorge; Cantarero-Roldán, Alicia; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2018-08-15
A novel approach for serum analysis by dried matrix spot (DMS) technique is proposed. The methodology consists of sampling filter paper discs (2.7 mm in diameter) containing the large amount of serum retained after a single spotting. Several oxidizers (sodium chlorate, sodium azide, acetic acid, formic acid, 1-butyl-3-methylimidazoliumm chloride/bromide) were tested (oxidizers premixed with the sample before spotting, and papers previously soaked in concentrated additive/oxidizer solutions). Direct multi-element determination (Al, Be, Ca, Cu, Fe, K, Li, Mg, Mn, Mo, Na, P, Rb, Se, V, and Zn) in dried serum spots at very low levels was therefore assessed by laser ablation (LA) coupled with inductively coupled plasma - mass spectrometry (ICP-MS). Laser ablation was performed using a focused Nd: YAG laser beam in lineal scan mode (wavelength 213 nm, laser fluency 2.2 J cm -2 , repetition rate 20 Hz, laser spot diameter 90 µm, depth 0 µm, scanning speed 12 µm s -1 ). Matrix-matched calibration mode and 13 C as internal standard (for signal intensities normalization) was used throughout the work. Limits of quantification were found to be from 21 µg L -1 to 221 mg L -1 . Repeatability (seven ablations of the same dried serum spot) and reproducibility (two ablations of seven dried serum spot from the same material) offered RSDs below 12% for all analytes, which seems satisfactory for clinical purposes. The method was validated by analyzing several certified reference materials (Seronorm™ level I and II trace elements in serum), and it was applied to several DMS from serum samples from healthy adults. Copyright © 2018 Elsevier B.V. All rights reserved.
Inoue, K; Kato, K; Yoshimura, Y; Makino, T; Nakazawa, H
2000-11-10
A simple and sensitive method using high-performance liquid chromatography with multi-electrode electrochemical detection (HPLC-ED) including a coulometric array of four electrochemical sensors has been developed for the determination of bisphenol A in water and human serum. For good separation and detection of bisphenol A, a CAPCELL PAK UG 120 C18 reversed-phase column and a mobile phase consisting of 0.3% phosphoric acid-acetonitrile (60:40) were used. The detection limit obtained by the HPLC-ED method was 0.01 ng/ml (0.5 pg), which was more than 3000-times higher than the detection limit obtained by the ultraviolet (UV) method, and more than 200-times higher than the detection limit obtained by the fluorescence (FL) method. Bisphenol A in water and serum samples was pretreated by solid-phase extraction (SPE) after removing possible contamination derived from a plastic SPE cartridges and water used for the pretreatment. A trace amount (ND approximately 0.013 ng/ml) of bisphenol A was detected from the parts of cartridges (filtration column, sorbent bed and frits) by extraction with methanol, and it was completely removed by washing with at least 15 ml of methanol in the operation process. The concentrations of bisphenol A in tap water and Milli-Q-purified water were found to be 0.01 and 0.02 ng/ml, respectively. For that reason, bisphenol A-free water was made to trap bisphenol A in water using an Empore disk. In every pretreatment, SPE methods using bisphenol A-free water and washing with 15 ml of methanol were done in water and serum samples. The yields obtained from the recovery tests using water to which 0.5 or 0.05 ng/ml of bisphenol A was added were 83.8 to 98.2%, and the RSDs were 3.4 to 6.1%, respectively. The yields obtained from the recovery tests by OASIS HLB using serum to which 1.0 ng/ml or 0.1 ng/ml of bisphenol A was added were 79.0% and 87.3%, and the RSDs were 5.1% and 13.5%, respectively. The limits of quantification in water and serum sample were 0.01 ng/ml and 0.05 ng/ml, respectively. The method was applied to the determination of bisphenol A in healthy human serum sample, and the obtained detection was 0.32 ng/ml. From these results, the HPLC-ED method should be the most useful in the determination of bisphenol A at low concentration levels in water and biological samples.
Zhao, Mei-Fen; Huang, Peng; Ge, Chun-Lin; Sun, Tao; Ma, Zhi-Gang; Ye, Fei-Fei
2016-02-28
To identify conjugated bile acids in gallbladder bile and serum as possible biomarkers for cholesterol polyps (CPs) and adenomatous polyps (APs). Gallbladder bile samples and serum samples were collected from 18 patients with CPs (CP group), 9 patients with APs (AP group), and 20 patients with gallstones (control group) from March to November, 2013. High performance liquid chromatography (HPLC) assay with ultraviolent detection was used to detect the concentration of 8 conjugated bile acids (glycocholic acid, GCA; taurocholic acid, TCA; glycochenodeoxycholic acid, GCDCA; taurochenodeoxycholic acid, TCDCA; glycodeoxycholic acid, GDCA; taurodeoxycholic acid, TDCA; taurolithocholic acid, TLCA; tauroursodeoxycholic acid, TUDCA) in bile samples and serum samples. The diagnostic efficacy of serum GCA, GCDCA and TCDCA was evaluated. These 8 conjugated bile acids in gallbladder bile and serum were completely identified within 10 minutes with good linearity (correlation coefficient: R>0.9900; linearity range: 3.91-500 µg/mL). Among these conjugated bile acids, the levels of gallbladder bile GCDCA and TCDCA in the CP group were significantly higher than those in the AP group (p<0.05). Furthermore, serum GCDCA and TCDCA as well as GCA were significantly higher in the AP group than the CP group (p<0.05). Serum GCDCA alone (≤12 µg/mL) had relatively better diagnostic efficacy than the other conjugated bile acids. The levels of serum GCA, GCDCA and TCDCA may be valuable for differentiation of APs and CPs.
Saoudi, Abdessattar; Fréry, Nadine; Zeghnoun, Abdelkrim; Bidondo, Marie-Laure; Deschamps, Valérie; Göen, Thomas; Garnier, Robert; Guldner, Laurence
2014-02-15
Although most organochlorine (OC) pesticides were banned in France in the 1970s and 1980s, they remain a source of public concern. Because of their high persistence in the environment, they are still detected in foodstuffs, leading to continued human exposure. The purpose of this study was to assess the distribution of serum organochlorine (OC) pesticides in the French adult population and to identify the main risk factors for p,p'-dichlorodiphenyl dichlorethylene (DDE), β-hexachlorocyclohexane (β-HCH) and hexachlorobenzene (HCB). The selected OC pesticides (HCB, DDE, DDT, α-HCH, β-HCB and γ-HCH) were measured in serum samples collected in 2006-2007 from 386 persons (aged 18-74 years) randomly selected among the participants in the clinical and biological component of the French Nutrition and Health Survey (Etude Nationale Nutrition Santé [ENNS]), a cross-sectional survey carried out in the general population. Collected data included biological samples, socio-demographic characteristics, and data about environmental and occupational exposure factors. Of the six OC pesticides investigated, the highest concentrations were observed for HCB, β-HCH and DDE. Median serum concentrations were as follows: 22.8 ng/g lipid for HCB, 0.74 and 27.0 ng/g lipid, respectively, for α- and ß-HCH, and 3.8 and 104.6 ng/g lipid, respectively, for DDT and DDE. Lindane (γ-HCH) was detected in approximately 10% of the sample. OC pesticide levels in serum in French adults were higher (except for DDT and DDE) than those observed in American, Canadian and German populations and generally lower than or in the same range as those observed in other European countries. The low serum DDT/DDE ratio in the present study (3.7%) would suggest that the concentrations observed for these two OC pesticides were mainly the result of past exposure. The most important predictors of serum DDE, HCB and β-HCH concentrations among the French adult population included individual factors (age, gender, BMI, etc.), dietary factors of animal and vegetable origin, and domestic use of pesticides (in vegetable gardens and/or fruit trees). For the first time in France, a human biomonitoring study has shown that exposure to OC pesticides remains common in the population. French concentrations were higher (except for DDT and DDE) or were similar to those observed in other developed countries. Copyright © 2013 Elsevier B.V. All rights reserved.
Klein, Joern; Hussain, Manzoor; Ahmad, Munir; Afzal, Muhammad; Alexandersen, Soren
2008-01-01
Background Foot-and-mouth disease (FMD) is endemic in Pakistan and causes huge economic losses. This work focus on the Landhi Dairy Colony (LDC), located in the suburbs of Karachi. LDC is the largest Buffalo colony in the world, with more than 300,000 animals (around 95% buffaloes and 5% cattle, as well as an unknown number of sheep and goats). Each month from April 2006 to April 2007 we collected mouth-swabs from apparently healthy buffaloes and cattle, applying a convenient sampling based on a two-stage random sampling scheme, in conjunction with participatory information from each selected farm. Furthermore, we also collected epithelium samples from animals with clinical disease, as well as mouth-swabs samples from those farms. In addition, we analysed a total of 180 serum samples randomly collecting 30 samples each month at the local slaughterhouse, from October 2006 to March 2007. Samples have been screened for FMDV by real-time RT-PCR and the partial or full 1D coding region of selected isolates has been sequenced. Serum samples have been analysed by applying serotype-specific antibody ELISA and non-structural proteins (NSP) antibody ELISA. Results FMDV infection prevalence at aggregate level shows an endemic occurrence of FMDV in the colony, with peaks in August 2006, December 2006 and February 2007 to March 2007. A significant association of prevalence peaks to the rainy seasons, which includes the coldest time of the year and the muslimic Eid-festival, has been demonstrated. Participatory information indicated that 88% of all questioned farmers vaccinate their animals. Analysis of the serum samples showed high levels of antibodies for serotypes O, A, Asia 1 and C. The median endpoint-titre for all tested serotypes, except serotype C, in VNT titration is at a serum dilution of equal or above 1/100. All 180 serum samples collected have been tested for antibodies against the non-structural proteins and all but four have been found positive. Out of the 106 swab-samples from apparently healthy and affected animals positive in real-time RT-PCR, we sequenced the partial or full 1D coding region from 58 samples. In addition we sequenced the full 1D coding region of 17 epithelium samples from animals with clinical signs of FMD. From all sequenced samples, swabs and epithelium, 19 belong to the regional PanAsia II lineage of serotype O and 56 to the A/Iran/2005 lineage of serotype A. Conclusion For an effective and realisable FMD control program in LDC, we suggest to introduce a twice annually mass vaccination of all buffaloes and cattle in the colony. These mass vaccinations should optimally take place shortly before the beginning of the two rainy periods, e.g. in June and September. Those vaccinations should, in our opinion, be in addition to the already individually performed vaccinations of single animals, as the latter usually targets only newly introduced animals. This suggested combination of mass vaccination of all large ruminants with the already performed individually vaccination should provide a continuous high level of herd immunity in the entire colony. Vaccines used for this purpose should contain the matching vaccine strains, i.e. as our results indicate antigens for A/Iran/2005 and the regional type of serotype O (PanAsia II), but also antigens of the, in this world region endemic, Asia 1 lineage should be included. In the long term it will be important to control the vaccine use, so that subclinical FMD will be avoided. PMID:18445264
Polyfluoroalkyl substance exposure in the Mid-Ohio River Valley, 1991-2012.
Herrick, Robert L; Buckholz, Jeanette; Biro, Frank M; Calafat, Antonia M; Ye, Xiaoyun; Xie, Changchun; Pinney, Susan M
2017-09-01
Industrial discharges of perfluorooctanoic acid (PFOA) to the Ohio River, contaminating water systems near Parkersburg, WV, were previously associated with nearby residents' serum PFOA concentrations above US general population medians. Ohio River PFOA concentrations downstream are elevated, suggesting Mid-Ohio River Valley residents are exposed through drinking water. Quantify PFOA and 10 other per- and polyfluoroalkyl substances (PFAS) in Mid-Ohio River Valley resident sera collected between 1991 and 2013 and determine whether the Ohio River and Ohio River Aquifer are exposure sources. We measured eleven PFAS in 1608 sera from 931 participants. Serum PFOA concentration and water source associations were assessed using linear mixed-effects models. We estimated between-sample serum PFOA using one-compartment pharmacokinetics for participants with multiple samples. In serum samples collected as early as 1991, PFOA (median = 7.6 ng/mL) was detected in 99.9% of sera; 47% had concentrations greater than US population 95th percentiles. Five other PFAS were detected in greater than 82% of samples; median other PFAS concentrations were similar to the US general population. Serum PFOA was significantly associated with water source, sampling year, age at sampling, tap water consumption, pregnancy, gravidity and breastfeeding. Serum PFOA was 40-60% lower with granular activated carbon (GAC) use. Repeated measurements and pharmacokinetics suggest serum PFOA peaked 2000-2006 for participants using water without GAC treatment; where GAC was used, serum PFOA concentrations decreased from 1991 to 2012. Mid-Ohio River Valley residents appear to have PFOA, but not other PFAS, serum concentrations above US population levels. Drinking water from the Ohio River and Ohio River Aquifer, primarily contaminated by industrial discharges 209-666 km upstream, is likely the primary exposure source. GAC treatment of drinking water mitigates, but does not eliminate, PFOA exposure. Copyright © 2017 Elsevier Ltd. All rights reserved.
Craig, A M; Blythe, L L; Rowe, K E; Lassen, E D; Barrington, R; Walker, K C
1992-12-01
Recent evidence concerning the pathogenesis of equine degenerative myeloencephalopathy indicated that low blood alpha-tocopherol values are a factor in the disease process. Variables that could be introduced by a veterinarian procuring, transporting, or storing samples were evaluated for effects on alpha-tocopherol concentration in equine blood. These variables included temperature; light; exposure to the rubber stopper of the evacuated blood collection tube; hemolysis; duration of freezing time, with and without nitrogen blanketing; and repeated freeze/thaw cycles. It was found that hemolysis caused the greatest change in high-performance liquid chromatography-measured serum alpha-tocopherol values, with mean decrease of 33% (P < 0.001). Lesser, but significant (P < 0.01) changes in serum alpha-tocopherol values were an approximate 10% decrease when refrigerated blood was left in contact with the red rubber stopper of the blood collection tube for 72 hours and an approximate 5% increase when blood was stored at 20 to 25 C (room temperature) for 72 hours. Repeated freeze/thaw cycles resulted in a significant (P < 0.05) 3% decrease in alpha-tocopherol values in heparinized plasma by the third thawing cycle. Freezer storage for a 3-month period without nitrogen blanketing resulted in slight (2%) decrease in mean serum alpha-tocopherol values, whereas values in serum stored for an identical period under nitrogen blanketing did not change. A significant (P < 0.001) mean decrease (10.3%) in alpha-tocopherol values was associated with freezer (-16 C) storage of nitrogen blanketed serum for 6 months.(ABSTRACT TRUNCATED AT 250 WORDS)
Aydemir, Omer; Deveci, Artuner; Taskin, Oryal E; Taneli, Fatma; Esen-Danaci, Aysen
2007-06-30
In this present work, it is aimed to demonstrate BDNF serum concentrations in patients with dysthymia and to compare them with BDNF serum concentrations in patients with major depressive disorder and healthy subjects. The study was carried out in Celal Bayar University Hospital, Manisa, Turkey. Seventeen patients with dysthymia, 24 patients with major depressive disorder and 26 subjects without any psychiatric diagnosis and any psychiatric treatment were included in the study. The severity of depression was assessed with 17-item HAM-D. All subjects were asked to give their written consent. Blood samples were collected at baseline. Serum BDNF was kept at -70 degrees C before testing, and assayed with an ELISA Kit (Promega; Madison, WI, USA), after dilution with the Block and Sample solution provided with the kit. The data were subjected to the analysis of variance. The BDNF serum concentrations of the dysthymia group (mean=28.9+/-9.2 ng/ml) were significantly higher than that of the major depressive disorder group (21.2+/-11.3 ng/ml) (p=0.002), and it was not different from the level of the control group (31.4+/-8.8 ng/ml). BDNF serum concentrations and HAM-D score did not have any significant correlation in the dysthymia and major depression groups (r=-0.276, p=0.086). The low level of BDNF in patients with dysthymic disorder seems to point out that BDNF changes in mood disorders are state-dependent and vary according to the severity of depressive episodes.
Grapp, Marcel; Kaufmann, Christoph; Streit, Frank; Binder, Lutz
2018-06-01
Comprehensive screening procedures for psychoactive agents in body fluids are an essential task in clinical and forensic toxicology. With the continuous emergence and adaption of new psychoactive substances (NPS) keeping a screening method up to date is challenging. To meet these demands, hyphenated high-resolution mass spectrometry has gained interest as extensive and expandable screening approach. Here we present a comprehensive method for systematic toxicological analysis of serum by liquid chromatography-quadrupole-time-of-flight mass spectrometry (LC-QTOF-MS) with data independent acquisition. The potential of this method was demonstrated by analysis of 247 authentic serum- and 12 post-mortem femoral blood samples. Thus 950 compounds, comprising 185 different drugs and metabolites could be identified. For the detected substances, including pharmaceutical substances, illicit drugs as well as NPS, serum concentrations were confirmed ranging from traces to toxic values indicating the capability for forensic toxicological requirements. Positive identification of drugs was achieved by accurate mass measurement (±5ppm for [M+H] + ; ±10ppm for [M-H] - ), retention time (±0.35min), isotopic pattern match (less than 10 m/z RMS [ppm]), isotope match intensity (less than 20% RMS) and the presence of at least two fragment ions. The LC-QTOF-MS procedure was shown to be superior to serum screening by GC-MS, since 240% (335 versus 141) more drugs were identified in serum samples compared to GC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Lei; Zhong, Yuxin; Liu, Xin; Bao, Yan; Zhao, Yunfeng; Wu, Yongning; Cai, Zongwei; Li, Jingguang
2017-09-01
The determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in blood from a non-occupational population is essential for the investigation of adverse health effects from these pollutants. In this study, a sensitive method based on programmable-temperature vaporization with large-volume injection coupled with gas chromatography with high-resolution mass spectrometry was developed to determine these pollutants in 1-2 mL of human serum samples. Various key parameters of programmable-temperature vaporization injector, including vent temperature, vent time, vent flow, transfer temperature and transfer time were optimized by factorial design. The accuracy and precision as well as applicability were assessed by determining polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in calibration standard solutions, standard reference materials and real human serum samples from non-occupational population. The method detection limits of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls were 1.5-9.0 and 0.005-0.02 ng/kg wet weight, respectively. By comparing with typically splitless injection, the application of programmable-temperature vaporization injector could effectively lead to higher detectable rate of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in 1-2 mL of human serum samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development of optical immunosensors for detection of proteins in serum.
Kyprianou, Dimitris; Chianella, Iva; Guerreiro, Antonio; Piletska, Elena V; Piletsky, Sergey A
2013-01-15
The detection of proteins in biological samples such as blood, serum or plasma by biosensors is very challenging due to the complex nature of the matrix, which contains a high level of many interfering compounds. Here we show the application of a novel polymeric immobilisation matrix that helps in the detection of specific protein analytes in biological samples by surface plasmon resonance (SPR) immunosensors. This polymer matrix contains thioacetal functional groups included in the network, and these groups do not require any further activation in order to react with proteins, making it attractive for sensor fabrication. The protein prostate specific antigen (PSA) was selected as a model target analyte. A sandwich format with two primary antibodies recognising different parts (epitopes) of the analyte was used for the detection of PSA in serum. The efficiency of the reduction of non-specific binding achieved with novel polymer was compared with those of other techniques such as coating of sensor surface with polyethylene glycol (PEG), use of charged hydrophilic aspartic acid and surfactants such as Tween20. The detection limit of the polymer based immunosensor was 0.1 ng ml(-1) for free form PSA (f-PSA) in buffer and 5 ng ml(-1) in 20% serum. This is an improvement compared with similar devices reported on literature, indicating the potential of the immunosensor developed here for the analysis of real samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Zhao, Jing; Jin, Yan; Shin, Yujin; Jeong, Kyung Min; Lee, Jeongmi
2016-03-01
Here we describe a simple and sensitive analytical method for the enantioselective quantification of fluoxetine in mouse serum using ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry. The sample preparation method included a simple deproteinization with acetonitrile in 50 μL of serum, followed by derivatization of the extracts in 50 μL of 2 mM 1R-(-)-menthyl chloroformate at 45ºC for 55 min. These conditions were statistically optimized through response surface methodology using a central composite design. Under the optimized conditions, neither racemization nor kinetic resolution occurred. The derivatized diastereomers were readily resolved on a conventional sub-2 μm C18 column under a simple gradient elution of aqueous methanol containing 0.1% formic acid. The established method was validated and found to be linear, precise, and accurate over the concentration range of 5.0-1000.0 ng/mL for both R and S enantiomers (r(2) > 0.993). Stability tests of the prepared samples at three different concentration levels showed that the R- and S-fluoxetine derivatives were relatively stable for 48 h. No significant matrix effects were observed. Last, the developed method was successfully used for enantiomeric analysis of real serum samples collected at a number of time points from mice administered with racemic fluoxetine. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Castberg, Ingrid; Spigset, Olav
2008-10-01
The aim of this study was to investigate the use of psychotropic medication and therapeutic drug monitoring in a high-security psychiatric unit and to compare the doses and serum concentrations both with the recommended intervals and with the doses and serum concentrations in a control group. One hundred thirty-two patients were admitted in the period from January 2000 to December 2005. All available samples were used when comparing serum concentrations and doses with the recommended ranges. For the comparison of doses and serum concentration-to-dose (C:D) ratios with the control group only 1 sample from each patient was used. A total of 459 analyses of 27 different drugs in samples from 8 women and 73 men were included. The median number of therapeutic drug monitoring analyses per patient was 4 (range 1-29). Thirty-seven of the 81 patients (46%) used 2 or more antipsychotics at the same time. Clozapine, lamotrigine, olanzapine, quetiapine, ziprasidone, and zuclopenthixol were often given in doses above the recommended. The serum levels were frequently above those recommended for clozapine, olanzapine, quetiapine, risperidone, ziprasidone, and zuclopenthixol. The serum levels were significantly higher in the study group than in the control group for clozapine, lamotrigine, quetiapine, and zuclopenthixol. The given dose was significantly higher in the study group than in the control group for clozapine, lamotrigine and zuclopenthixol. The C:D ratio was significantly lower in the study group than in the control group for olanzapine but higher for quetiapine. The non-evidence based practice of high-dose polypharmacy with several antipsychotics is widely used in this unit. The use of higher doses in the study group than in the control group was not due to differences in metabolism or adherence to treatment between the 2 groups. The frequent use of therapeutic drug monitoring did not seem to have a great impact on the prescribed doses.
Moon, Sung-Sil; Groome, Michelle J; Velasquez, Daniel E; Parashar, Umesh D; Jones, Stephanie; Koen, Antoinette; van Niekerk, Nadia; Jiang, Baoming; Madhi, Shabir A
2016-01-15
Live oral rotavirus (RV) vaccines have shown modest efficacy among children in African countries for reasons that are not completely understood. We examined the possible inhibitory effect of preexisting antirotavirus antibodies on immunogenicity of monovalent RV vaccine (RV1). Mother-infant pairs were enrolled at presentation for their routine immunization visit in Soweto, South Africa, when infants were aged 5-8 weeks. Infant serum samples were obtained before the first and second doses of RV1 and 1 month after the second dose. Maternal serum and breast milk samples were obtained prior to administration of each dose of RV1 to infants. RV-specific immunoglobulin G (IgG), IgA, and neutralizing activity in sera of infants and serum or breast milk samples of mothers were measured using enzyme-linked immunosorbent assays or a microneutralization test. Of the 107 serum pairs from infants who were seronegative for RV IgA at enrollment, we observed a strong positive association between IgG titers in pre-dose 1 sera of infants and mothers and significant negative associations between IgG titers in pre-dose 1 sera of infants and seroconversion to RV1 post-dose 1. Similarly, mothers whose infants' IgA seroconverted after RV1 had significantly lower pre-dose 1 IgG titers in sera than those whose infants did not seroconvert. High levels of preexisting serum IgG, including transplacentally acquired maternal IgG, appeared to have an inhibitory effect on the immunogenicity of RV1 among infants and may, in part, contribute to lower efficacy of RV vaccines in this and other low-income settings. Published by Oxford University Press for the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Shu, Irene; Wang, Ping
2013-06-01
Concentrations of nicotine and its metabolites in blood are indicative of patients' current tobacco exposure, and their quantifications have been clinically applied to multiple assessments including demonstration of abstinence prior to heart-lung transplantation. For the purpose of transplant evaluation, the laboratory work up is extensive; thereby an assay with minimal sample volume is preferred. We developed and validated a rapid LC-MS/MS assay to simultaneously quantitate nicotine and its major metabolites, Cotinine and trans-3'-OH-cotinine (3-OH-Cot), in serum. 100μL of serum was spiked with deuterated internal standards and extracted by Oasis HLB solid phase extraction cartridge. Nicotine and metabolites in the reconstituted serum extract were separated by Agilent Eclipse XDB-C8 3.5μm 2.1mm×50mm HPLC column within 4.7min, and quantified by MS/MS with positive mode electrospray ionization and multiple reaction monitoring. Ion suppression was insignificant, and extraction efficiency was 79-110% at 50ng/mL for all compounds. Limit of detection was 1.0ng/mL for nicotine and 3-OH-Cot, and <0.5ng/mL for Cotinine. Linearity ranges for nicotine, cotinine and 3-OH-Cot were 2-100, 2-1000, and 5-1000ng/mL with recoveries of 86-115%. Within-day and twenty-day imprecision at nicotine/cotinine/3-OH-Cot levels of 22/150/90, 37/250/150, and 50/800/500ng/mL were all 1.1-6.5%. The reconstituted serum extracts were stable for at least 7 days stored in the HPLC autosampler at 5°C. Our method correlates well with alternative LC-MS/MS methods. We successfully developed and validated an LC-MS/MS assay to quantitate concentrations of nicotine and its metabolites in serum with minimal sample volume to assess tobacco exposure of heart-lung transplant patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Parkinson, I S; Ward, M K; Kerr, D N
1982-10-27
A simple but reliable method for the routine determination of aluminium in serum and water by flameless atomic absorption spectrometry is described. No preparatory procedures are required for water samples, although serum is mixed with a wetting agent (Triton X-100) to allow complete combustion of the samples and to improve analytical precision. Precautions to prevent contamination during sample handling are discussed and instrumental parameters are defined. The method has a sensitivity of 35.5 pg and detection limits of 2.3 micrograms Al/l for serum and 1.3 micrograms Al/l for water. The method was used to determine the aluminium concentration in serum of 46 normal subjects. The mean aluminium content was 7.3 micrograms/l (range 2--15 micrograms/l.
Bead-based microfluidic immunoassay for diagnosis of Johne's disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wadhwa, Ashutosh; Foote, Robert; Shaw, Robert W
2012-01-01
Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types ofmore » SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.« less
Association of testosterone and BDNF serum levels with craving during alcohol withdrawal.
Heberlein, Annemarie; Lenz, Bernd; Opfermann, Birgitt; Gröschl, Michael; Janke, Eva; Stange, Katrin; Groh, Adrian; Kornhuber, Johannes; Frieling, Helge; Bleich, Stefan; Hillemacher, Thomas
2016-08-01
Preclinical and clinical studies show associations between testosterone and brain-derived neurotrophic growth factor (BDNF) serum levels. BDNF and testosterone have been independently reported to influence alcohol consumption. Therefore, we aimed to investigate a possible interplay of testosterone and BDNF contributing to alcohol dependence. Regarding possible interplay of testosterone and BDNF and the activity of the hypothalamic pituitary axis (HPA), we included cortisol serum levels in our research. We investigated testosterone and BDNF serum levels in a sample of 99 male alcohol-dependent patients during alcohol withdrawal (day 1, 7, and 14) and compared them to a healthy male control group (n = 17). The testosterone serum levels were significantly (p < 0.001) higher in the patients' group than in the control group and decreased significantly during alcohol withdrawal (p < 0.001). The decrease of testosterone serum levels during alcohol withdrawal (days 1-7) was significantly associated with the BDNF serum levels (day 1: p = 0.008). In a subgroup of patients showing high cortisol serum levels (putatively mirroring high HPA activity), we found a significant association of BDNF and testosterone as well as with alcohol craving measured by the Obsessive and Compulsive Drinking Scale (OCDS). Our data suggest a possible association of BDNF and testosterone serum levels, which may be relevant for the symptomatology of alcohol dependence. Further studies are needed to clarify our results. Copyright © 2016 Elsevier Inc. All rights reserved.
Korosue, Kenji; Murase, Harutaka; Sato, Fumio; Ishimaru, Mutsuki; Kotoyori, Yasumitsu; Nambo, Yasuo
2012-11-01
The object of this study was to evaluate the usefulness of measuring the differences in the values of the serum total protein (DVSTP) concentration of foals and the refractometry index (DVRI) of the milk of dams before and after nursing of the colostrum for assessing failure of passive transfer (FPT) in foals. Serum samples from 31 foals were collected before the first nursing and other 1 to 6 times between 4 and 24 hr after birth. Paired colostrum and milk samples were collected from 14 of their dams at the same time. Serum samples were analyzed for IgG concentration using a single radial immunodiffusion (SRID) test (98 samples) and total protein concentration using a temperature-compensating refractometer (98 samples). Colostrum and milk samples were analyzed for refractometry index (RI) using a Brix refractometer (71 samples). DVSTP concentration and DVRI were significantly correlated with serum IgG concentration. The negative predictive values (NPVs) of DVSTP concentration for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 98.2% and 91.3% when the cutoff value is set to 0.4 mg/dl and 0.8 mg/dl, respectively. Furthermore, the NPVs of DVRI for detecting serum IgG concentrations<400 mg/dl and<800 mg/dl were 97.3% and 96.3% when the cutoff value is set to 6% and 10%, respectively. The results suggest that measurement of DVRI is useful in assessing FPT as an initial "stall-side" screening test, because it is easy, inexpensive to perform and allows for rapid interpretation.
Buttke, Danielle E; Wolkin, Amy; Stapleton, Heather M; Miranda, Marie Lynn
2013-03-01
Polybrominated diphenyl ethers (PBDE) are flame retardants that were previously used in upholstery, fabrics, and household appliances. PBDEs have been linked to adverse health outcomes, including neurotoxicity, thyroid hormone dysregulation, endocrine disruption, and poor semen quality. Because PBDEs pass into placental circulation, maternal exposures can approximate fetal exposures. Our objectives were to determine whether diet and specific human behaviors were significantly associated with PBDE exposures in a cohort of pregnant women. Women between the 34th and 38th week of pregnancy were given a questionnaire about behavioral, environmental, and dietary factors and asked to provide blood samples. Serum PBDE levels were measured using GS-MS and lipid adjusted. An adjusted ordinary least squares regression model was run to identify potential associations between behaviors and serum PBDE levels. Serum concentrations of BDEs 47, 99, 100, and 153 were found above the limit of detection in at least 50% of study participants and used in our models. Associations with serum PBDEs were observed with self-reported hand-to-mouth behaviors, including biting nails and licking fingers. Serum BDE levels of 47, 99, 153, and total PBDEs were also significantly higher in those individuals owning a large-screen TV compared with those who did not. Serum PBDE levels were comparable to levels reported in the general population. Hand-to-mouth behaviors may influence serum PBDE concentrations in adults. Household electronics such as large-screen TVs appear to serve as a significant source of PBDEs in pregnant women. Together, hand-to-mouth behaviors and TV ownership may serve as a route of exposure to PBDEs in adults.
Buttke, Danielle E.; Wolkin, Amy; Stapleton, Heather M.; Miranda, Marie Lynn
2015-01-01
Background Polybrominated diphenyl ethers (PBDE) are flame retardants that were previously used in upholstery, fabrics, and household appliances. PBDEs have been linked to adverse health outcomes, including neurotoxicity, thyroid hormone dysregulation, endocrine disruption, and poor semen quality. Because PBDEs pass into placental circulation, maternal exposures can approximate fetal exposures. Objectives Our objectives were to determine if diet and specific human behaviors were significantly associated with PBDE exposures in a cohort of pregnant women. Methods Women between the 34th and 38th week of pregnancy were given a questionnaire about behavioral, environmental, and dietary factors and asked to provide blood samples. Serum PBDE levels were measured using GS-MS and lipid adjusted. An adjusted ordinary least squares regression model was run to identify potential associations between behaviors and serum PBDE levels. Results Serum concentrations of BDEs 47, 99, 100, and 153 were found above the limit of detection in at least 50% of study participants and used in our models. Associations with serum PBDEs were observed with self-reported hand-to-mouth behaviors, including biting nails and licking fingers. Serum BDE levels of 47, 99, 153, and total PBDEs were also significantly higher in those individuals owning a large screen TV compared to those who did not. Serum PBDE levels were comparable to levels reported in the general population. Conclusions Hand-to-mouth behaviors may influence serum PBDE concentrations in adults. Household electronics such as large-screen TV’s appear to serve as a significant source of PBDEs in pregnant women. Together, hand-to-mouth behaviors and TV ownership may serve as a route of exposure to PBDEs in adults. PMID:22760441
Influence of the collection tube on metabolomic changes in serum and plasma.
López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D
2016-04-01
Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Chaya, DR; Parija, Subhash Chandra
2014-01-01
Introduction: Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. Materials and Methods: An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Results: Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Conclusions: Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis. PMID:24754027
Chaya, Dr; Parija, Subhash Chandra
2014-01-01
Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.
Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro
2015-01-01
Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were <0.50 for 48% of amino acids, 27% of acylcarnitines, 18% of lysophosphatidylcholines and 4% of phosphatidylcholines. In non-fasting samples, the median ICC was 0.54. ICC values were <0.50 for 71% of acylcarnitines, 48% of amino acids, 44% of biogenic amines, 36% of sphingomyelins, 34% of phosphatidylcholines and 33% of lysophosphatidylcholines. Overall, reproducibility was lower in non-fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920
AhR transcriptional activity in serum of Inuits across Greenlandic districts
Long, Manhai; Deutch, Bente; Bonefeld-Jorgensen, Eva C
2007-01-01
Background Human exposure to lipophilic persistent organic pollutants (POPs) including polychlorinated dibenzo-p-dioxins/furans (PCDDs/PCDFs), polychlorinated biphenyls (PCBs) and organochlorine pesticide is ubiquitous. The individual is exposed to a complex mixture of POPs being life-long beginning during critical developmental windows. Exposure to POPs elicits a number of species- and tissue-specific toxic responses, many of which involve the aryl hydrocarbon receptor (AhR). The aim of this study was to compare the actual level of integrated AhR transcriptional activity in the lipophilic serum fraction containing the actual POP mixture among Inuits from different districts in Greenland, and to evaluate whether the AhR transactivity is correlated to the bio-accumulated POPs and/or lifestyle factors. Methods The study included 357 serum samples from the Greenlandic districts: Nuuk and Sisimiut (South West Coast), Qaanaaq (North Coast) and Tasiilaq (East Coast). The bio-accumulated serum POPs were extracted by ethanol: hexane and clean-up on Florisil columns. Effects of the serum extract on the AhR transactivity was determined using the Hepa 1.12cR mouse hepatoma cell line carrying an AhR-luciferase reporter gene, and the data was evaluated for possible association to the serum levels of 14 PCB congeners, 10 organochlorine pesticide residues and/or lifestyle factors. Results In total 85% of the Inuit samples elicited agonistic AhR transactivity in a district dependent pattern. The median level of the AhR-TCDD equivalent (AhR-TEQ) of the separate genders was similar in the different districts. For the combined data the order of the median AhR-TEQ was Tasiilaq > Nuuk ≥ Sisimiut > Qaanaaq possibly being related to the different composition of POPs. In overall, the AhR transactivity was inversely correlated to the levels of sum POPs, age and/or intake of marine food. Conclusion i) We observed that the proportion of dioxin like (DL) compounds in the POP mixture was the dominating factor affecting the level of serum AhR transcriptional activity even at very high level of non DL-PCBs; ii) The inverse association between the integrated serum AhR transactivity and sum of POPs might be explained by the higher level of compounds antagonizing the AhR function probably due to selective POP bioaccumulation in the food chain. PMID:17956617
Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K
2012-04-30
Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.
Serum zinc concentrations: contamination from laboratory equipment.
Ralstin, J O; Schneider, P J; Blackstone, L; Ruberg, R L
1979-01-01
The following experiment was designed because of high serum zinc reported in patients who were reciving total parenteral nutrition (TPN) concentrations. Blood samples were collected, divided into 3 containers: a clean glass control test tube, a vacuum collecting tube with a rubber stopper, and paraffin clot activator. It was found that compared to glass control tubes, vacuum collection with rubber stoppers contributed an average of 76 +/- 14 microgram/dl of zinc as contaminants. Moreover, tubes with a rubber stopper and clot activator contributed 198 +/- 42 microgram/dl of zinc as contaminants. It is concluded that care must be used to avoid trace element contaminants when plasma zinc concentrations are analyzed. Without proper methodology, including selection of the container in which the sample is taken, erroneous results will be reported.
An enzyme-linked immunosorbent assay for the evaluation of thrombocytopenia induced by heparin.
Howe, S E; Lynch, D M
1985-05-01
Five patients with heparin-associated thrombocytopenia (HAT) were evaluated by platelet aggregation and quantitation of immunoglobulin binding to intact target platelets in both the presence and absence of heparin. These patients developed thrombocytopenia (12,000 to 70,000 platelets/microliter) 7 to 15 days and embolic and hemorrhagic complications 9 to 15 days after the initiation of heparin therapy. Platelet aggregation after the addition of heparin was demonstrated in two of four HAT serum samples, whereas normal serum samples showed no significant platelet aggregation. The five HAT serum samples showed normal to elevated baseline serum platelet-bindable immunoglobulin (SPBIg) with a range of 4.3 to 11.4 fg/platelet (normal less than or equal to 1.0 to 6.5 fg/platelet). When HAT sera were incubated with target platelets and heparin (5 U/ml), the SPBIg increased to 8.5 to 37.5 fg/platelet, a mean increase of 148% in the presence of heparin. Normal and control serum samples (from 10 normal laboratory volunteers, nine patients without thrombocytopenia receiving heparin, nine patients with autoimmune thrombocytopenic purpura, and nine patients with nonimmune thrombocytopenia not receiving heparin) showed only a slight increase in SPBIg of 0 to 2.8 fg/platelet above baseline, a mean increase of 15% after heparin incubation with the serum samples. The measurement of SPBIg of washed platelets incubated with test serum samples in the presence and absence of heparin is potentially a specific and sensitive in vitro test for the diagnosis of HAT and may prove more sensitive than platelet aggregation studies with heparin.
Aneurysmal subarachnoid hemorrhage lead to systemic upregulation of IL-23/IL-17 inflammatory axis.
Chaudhry, Shafqat Rasul; Güresir, Erdem; Vatter, Hartmut; Kinfe, Thomas M; Dietrich, Dirk; Lamprecht, Alf; Muhammad, Sajjad
2017-09-01
IL-23 and IL-17 are pro-inflammatory cytokines. IL-23 is secreted by activated macrophages and dendritic cells, while IL-17 by Th17 cells. Serum IL-23 and IL-17 are known to be elevated in numerous inflammatory diseases including neurodegenerative diseases. The role of serum IL-23 and IL-17 in aneurysmal subarachnoid hemorrhage (aSAH) has still not been investigated. The present work investigates the serum IL-23 and IL-17 levels and their association with post hemorrhagic complications and clinical outcome in patients with aSAH. In this study, 80 patients with aSAH (Hunt and Hess grade I-V) were prospectively recruited. We enrolled 24 control patients with lumbar spinal stenosis. Peripheral venous blood was withdrawn from controls and from aSAH patients at day 1 and day 7, allowed to clot and centrifuged to obtain serum. Enzyme linked immunoassay kits were employed to quantify the serum levels of IL-23 and IL-17 by applying 50µL of serum samples. Post hemorrhagic complications and clinical outcome were documented prospectively from patient's hospital record. Serum IL-23 and IL-17 levels were significantly elevated in aSAH patients at day 1 and day 7 (n=80) as compared to control patients (n=24). Further analysis after dichotomy of patients who suffered from post hemorrhagic complications including cerebral vasospasm, chronic hydrocephalus, seizures, cerebral ischemia, delayed neurological deficits showed differential correlations with different post hemorrhagic complications (Table 1). Serum IL-23 and IL-17 levels did not correlate with clinical outcome. Serum IL-23 and IL-17 levels were elevated in patients with aSAH showing upregulation of IL-23/IL-17 inflammatory axis after aSAH. Serum IL-23 and IL-17 showed differential correlations with post hemorrhagic complications and no correlation with clinical outcome. Copyright © 2017 Elsevier Ltd. All rights reserved.
METHOD FOR MICRORNA ISOLATION FROM CLINICAL SERUM SAMPLES
Li, Yu; Kowdley, Kris V.
2012-01-01
MicroRNAs are a group of intracellular non-coding RNA molecules that have been implicated in a variety of human diseases. Due to their high stability in blood, microRNAs released into circulation could be potentially utilized as non-invasive biomarkers for diagnosis or prognosis. Current microRNA isolation protocols are specifically designed for solid tissues and are impractical for biomarker development utilizing small-volume serum samples on a large scale. Thus, a protocol for microRNA isolation from serum is needed to accommodate these conditions in biomarker development. To establish such a protocol, we developed a simplified approach to normalize sample input by using single synthetic spike-in microRNA. We evaluated three commonly used commercial microRNA isolation kits for the best performance by comparing RNA quality and yield. The manufacturer’s protocol was further modified to improve the microRNA yield from 200 μL of human serum. MicroRNAs isolated from a large set of clinical serum samples were tested on the miRCURY LNA real-time PCR panel and confirmed to be suitable for high-throughput microRNA profiling. In conclusion, we have established a proven method for microRNA isolation from clinical serum samples suitable for microRNA biomarker development. PMID:22982505
Clendenen, Tess V; Rendleman, Justin; Ge, Wenzhen; Koenig, Karen L; Wirgin, Isaac; Currie, Diane; Shore, Roy E; Kirchhoff, Tomas; Zeleniuch-Jacquotte, Anne
2015-01-01
Large epidemiologic studies have the potential to make valuable contributions to the assessment of gene-environment interactions because they prospectively collected detailed exposure data. Some of these studies, however, have only serum or plasma samples as a low quantity source of DNA. We examined whether DNA isolated from serum can be used to reliably and accurately genotype single nucleotide polymorphisms (SNPs) using Sequenom multiplex SNP genotyping technology. We genotyped 81 SNPs using samples from 158 participants in the NYU Women's Health Study. Each participant had DNA from serum and at least one paired DNA sample isolated from a high quality source of DNA, i.e. clots and/or cell precipitates, for comparison. We observed that 60 of the 81 SNPs (74%) had high call frequencies (≥95%) using DNA from serum, only slightly lower than the 85% of SNPs with high call frequencies in DNA from clots or cell precipitates. Of the 57 SNPs with high call frequencies for serum, clot, and cell precipitate DNA, 54 (95%) had highly concordant (>98%) genotype calls across all three sample types. High purity was not a critical factor to successful genotyping. Our results suggest that this multiplex SNP genotyping method can be used reliably on DNA from serum in large-scale epidemiologic studies.
Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D
2014-04-01
The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.
May, J C; Rains, T C; Maienthal, F J; Biddle, G N; Progar, J J
1986-10-01
Approximately 85 samples of injectable biological products regulated by the Center for Drugs and Biologics of the United States Food and Drug Administration were surveyed for the presence of 11 elements, namely aluminum, arsenic, barium, cadmium, chromium, lead, mercury, selenium, thallium and zinc, by flame and flameless methods of atomic absorption spectrometry and flame emission spectrometry. The range of products tested included whole blood, red cells, plasma, normal serum albumin, antihemophilic factor, and other products derived from blood; allergenic extracts including honey bee venom and house dust allergenic extracts; vaccines such as measles virus vaccine and typhoid vaccine; and tetanus toxoid. The metal concentrations found in the majority of these products were low or undetectable. The metal levels varied from manufacturer to manufacturer, product and lot-to-lot of the same manufacturer's products. House dust allergenic extracts had the highest concentrations of arsenic (2.4 ppm), cadmium (0.28 ppm), chromium (0.6 ppm) and lead (1.5 ppm) found in the study. A high zinc concentration (24 ppm) in an immune serum globulin was attributed to the zinc-containing rubber stopper in contact with the product. A range of 0.36-3.30 ppm aluminum was found for seven 25% normal serum albumin samples from seven manufacturers. Values of 8.2, 17 and 18 ppm aluminum were found in one manufacturer's 25% normal serum albumin. These aluminum values appeared to be the result of an anomaly in this manufacturer's production that has not been repeated to date.
Body Fluids as a Source of Diagnostic Biomarkers: Prostate — EDRN Public Portal
Recent advances in high-throughput protein expression profiling of bodily fluids has generated great enthusiasm and hope for this approach as a potent diagnostic tool. At the center of these efforts is the application of SELDI-TOF-MS and artificial intelligence algorithms by the EDRN BDL site at Eastern Virginia Medical School and the DMCC respectively. When the expression profiling process was applied to sera from individuals with prostate cancer (N=197), BPH (N=92) or from otherwise healthy donors (N=97) we achieved an overall misclassification rate of 90% sensitivity. Since this represents a noticeable improvement in current clinical approach we are proposing to embark upon a validation process. The described studies are designed to address validation issues and include three phases. Phase 1; Synchronization of SELDI Output within the EDRN-Prostate-SELDI Investigational Collaboration (EPSIC); addressing portability (A) Synchronize SELDI instrumentation and robotic sample processing across the EPSIC using pooled serum(QC); (B) Establish the portability and reproducibility of the SELDI protein profiling approach within the EPSIC using normal and prostate cancer patient’s serum from a single site; (C) Establish robustness of the approach toward geographic, sample collection and processing differences within EPSIC using case and control serum from five different sites. Phase 2; Population Validation Establish geographic variability and robustness in a large cross-sectional study among different sample population. Phase 3; Clinical Validation; validate the serum protein expression profiling coupled with a learning algorithm as a means for early detection of prostate cancer using longitudinal PCPT samples. We have assembled a cohesive multi-institutional team for completing these studies in a timely and efficient manner. The team consists of five EDRN laboratories, DMCC and CBI and the proposed budget reflects the total involvement.
Lu, Dasheng; Jin, Yu'e; Feng, Chao; Wang, Dongli; Lin, Yuanjie; Qiu, Xinlei; Xu, Qian; Wen, Yimin; She, Jianwen; Wang, Guoquan; Zhou, Zhijun
2017-09-01
Commonly, analytical methods measuring brominated flame retardants (BFRs) of different chemical polarities in human serum are labor consuming and tedious. Our study used acidified diatomaceous earth as solid-phase extraction (SPE) adsorbent and defatting material to simultaneously determine the most abundant BFRs and their metabolites with different polarities in human serum samples. The analytes include three types of commercial BFRs, tetrabromobisphenol A (TBBPA), hexabromocyclododecane (HBCD) isomers, and polybrominated biphenyl ethers (PBDEs), and dominant hydroxylated BDE (OH-PBDE) and methoxylated BDE (MeO-PBDE) metabolites of PBDEs. The sample eluents were sequentially analyzed for PBDEs and MeO-BDEs on online gel permeation chromatography/gas chromatography-electron capture-negative ionization mass spectrometry (online GPC GC-ECNI-MS) and for TBBPA, HBCD, and OH-BDEs on liquid chromatography-tandem mass spectrometry (LC-MS/MS). Method recoveries were 67-134% with a relative standard deviation (RSD) of less than 20%. Method detection limits (MDLs) were 0.30-4.20 pg/mL fresh weight (f.w.) for all analytes, except for BDE-209 of 16 pg/mL f.w. The methodology was also applied in a pilot study, which analyzed ten real samples from healthy donors in China, and the majority of target analytes were detected with a detection rate of more than 80%. To our knowledge, it is the first time for us in effectively determining BFRs of most types in one aliquot of human serum samples. This new analytical method is more specific, sensitive, accurate, and time saving for routine biomonitoring of these BFRs and for integrated assessment of health risk of BFR exposure.
Anti-complement activities of human breast-milk.
Ogundele, M O
1999-08-01
It has long been observed that the human milk possesses significant anti-inflammatory properties, while simultaneously protecting the infant against many intestinal and respiratory pathogens. There is, however, a paucity of information on the degree and extent of this anti-inflammatory activity. In the present study, the inhibitory effects of different fractions of human milk on serum complement activity were analysed. Colostrum and milk samples from healthy voluntary lactating donors at different postpartum ages were obtained and pooled normal human serum was used as source of complement in a modified CH50 assay. Inherent complement activity in human milk was also investigated by measuring the deposition of an activated C3 fragment on a serum-sensitive bacteria, and by haemolytic assays. Most whole- and defatted-milk samples consistently showed a dose-dependent inhibition of the serum complement activity. This inhibition was greater in mature milk compared to transitional milk samples. It was enhanced by inactivation of milk complement, and diminished by centrifugation of milk samples, which partly removed fat and larger protein components including casein micelles. Inherent complement activity in human milk was also demonstrated by haemolysis of sensitised sheep erythrocytes and deposition of C3 fragments on solid-phase bacteria. These activities were highest in the colostrum and gradually decreased as lactation proceeded. Several natural components abundant in the fluid phase of the human breast-milk have been shown to be inhibitors of complement activation in vitro. Their physiological significance probably reside in their ability to prevent inflammatory-induced tissue damage of the delicate immature gastrointestinal tract of the new-born as well as the mammary gland itself, which may arise from ongoing complement activation.
Chung, Chungwon J; Clavijo, Alfonso; Bounpheng, Mangkey A; Uddowla, Sabena; Sayed, Abu; Dancho, Brooke; Olesen, Ian C; Pacheco, Juan; Kamicker, Barbara J; Brake, David A; Bandaranayaka-Mudiyanselage, Carey L; Lee, Stephen S; Rai, Devendra K; Rieder, Elizabeth
2018-06-01
The highly contagious foot-and-mouth disease virus (FMDV) afflicts cloven-hoofed animals, resulting in significant costs because of loss of trade and recovery from disease. We developed a sensitive, specific, and rapid competitive ELISA (cELISA) to detect serum antibodies to FMDV. The cELISA utilized a monoclonal blocking antibody specific for a highly conserved FMDV nonstructural 3B epitope, a recombinant mutant FMDV 3ABC coating protein, and optimized format variables including serum incubation for 90 min at 20-25°C. Samples from 16 animals experimentally infected with one FMDV serotype (A, O, Asia, or SAT-1) demonstrated early detection capacity beginning 7 d post-inoculation. All samples from 55 vesicular stomatitis virus antibody-positive cattle and 44 samples from cloven-hoofed animals affected by non-FMD vesicular diseases were negative in the cELISA, demonstrating 100% analytical specificity. The diagnostic sensitivity was 100% against sera from 128 cattle infected with isolates of all FMDV serotypes, emphasizing serotype-agnostic results. Diagnostic specificities of U.S. cattle ( n = 1135) and swine ( n = 207) sera were 99.4% and 100%, respectively. High repeatability and reproducibility were demonstrated with 3.1% coefficient of variation in percent inhibition data and 100% agreement using 2 kit lots and 400 negative control serum samples, with no difference between bench and biosafety cabinet operation. Negative results from vaccinated, uninfected cattle, pig, and sheep sera confirmed the DIVA (differentiate infected from vaccinated animals) capability. This rapid (<3 h), select agent-free assay with high sensitivity and specificity, DIVA capability, and room temperature processing capability will serve as a useful tool in FMDV surveillance, emergency preparedness, response, and outbreak recovery programs.
Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan
2013-01-01
Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.
Garner, Bridget C; Kuroki, Keiichi; Stoker, Aaron M; Cook, Cristi R; Cook, James L
2013-03-01
To identify proteins with differential expression between healthy dogs and dogs with stifle joint osteoarthritis secondary to cranial cruciate ligament (CCL) disease. Serum and synovial fluid samples obtained from dogs with stifle joint osteoarthritis before (n = 10) and after (8) surgery and control dogs without osteoarthritis (9) and archived synovial membrane and articular cartilage samples obtained from dogs with stifle joint osteoarthritis (5) and dogs without arthritis (5). Serum and synovial fluid samples were analyzed via liquid chromatography-tandem mass spectrometry; results were compared against a nonredundant protein database. Expression of complement component 3 in archived tissue samples was determined via immunohistochemical methods. No proteins had significantly different expression between serum samples of control dogs versus those of dogs with stifle joint osteoarthritis. Eleven proteins (complement component 3 precursor, complement factor I precursor, apolipoprotein B-100 precursor, serum paraoxonase and arylesterase 1, zinc-alpha-2-glycoprotein precursor, serum amyloid A, transthyretin precursor, retinol-binding protein 4 precursor, alpha-2-macroglobulin precursor, angiotensinogen precursor, and fibronectin 1 isoform 1 preproprotein) had significantly different expression (> 2.0-fold) between synovial fluid samples obtained before surgery from dogs with stifle joint osteoarthritis versus those obtained from control dogs. Complement component 3 was strongly expressed in all (5/5) synovial membrane samples of dogs with stifle joint osteoarthritis and weakly expressed in 3 of 5 synovial membrane samples of dogs without stifle joint arthritis. Findings suggested that the complement system and proteins involved in lipid and cholesterol metabolism may have a role in stifle joint osteoarthritis, CCL disease, or both.
Can serums be replaced by Mueller-Hinton agar in germ tube test?
Atalay, M A; Koc, A N; Parkan, O M; Aydemir, G; Elmali, F; Sav, H
2017-01-01
The germ tube test (GTT) is inexpensive, easy, and well-defined test that differentiates Candida albicans (excluding Candida dubliniensis and Candida africana) from other species. The aim of this study was to evaluate various serums (i.e., human, rabbit, horse, and fetal bovine serum) used in the GTT and Mueller-Hinton agar (MHA). Fifty species isolated from various clinical samples that were defined as C. albicans by both conventional and DNA sequence analysis methods were included in the study. One to two colonies of C. albicans were mixed into 0.5-1 ml of fetal bovine serum, horse serum, rabbit serum, and human serum. Serums and MHA were incubated at 37°C for GTT. They were removed from the incubator and evaluated after 30 min, 1 h, 2 h, and 3 h of incubation. The GTT was accepted to be positive only if germ tube was 1/2 the width and 3 times the length of the parent yeast cell and with no constriction at the point of origin. When the use of serums and MHA for GTT was statistically evaluated, according to the positive scoring, the best results were obtained with MHA and with rabbit, horse, and fetal bovine serum, respectively. The best definition over time statistically was the third hour. It is suggested that inexpensive MHA is a fast, appropriate, and reliable medium for the probable diagnosis of GTT and C. albicans; however, additional studies are still needed to define other Candida species.
Brain-Derived Neurotrophic Factor in Patients with Huntington's Disease
Zuccato, Chiara; Mariotti, Caterina; Valenza, Marta; Lahiri, Nayana; Wild, Edward J.; Sassone, Jenny; Ciammola, Andrea; Bachoud-Lèvi, Anne Catherine; Tabrizi, Sarah J.; Di Donato, Stefano; Cattaneo, Elena
2011-01-01
Reduced Brain-Derived Neurotrophic Factor (BDNF) levels have been described in a number of patho-physiological conditions, most notably, in Huntington's disease (HD), a progressive neurodegenerative disorder. Since BDNF is also produced in blood, we have undertaken the measurement of its peripheral levels in the attempt to identify a possible link with HD prognosis and/or its progression. Here we evaluated BDNF level in 398 blood samples including 138 controls, 56 preHD, and 204 HD subjects. We found that BDNF protein levels were not reliably different between groups, whether measured in plasma (52 controls, 26 preHD, 105 HD) or serum (39 controls, 5 preHD, 29 HD). Our experience, and a re-analysis of the literature highlighted that intra-group variability and methodological aspects affect this measurement, especially in serum. We also assessed BDNF mRNA levels in blood samples from 47 controls, 25 preHD, and 70 HD subjects, and found no differences among the groups. We concluded that levels of BDNF in human blood were not informative (mRNA levels or plasma protein level) nor reliable (serum protein levels) as HD biomarkers. We also wish to warn the scientific community in interpreting the significance of changes measured in BDNF protein levels in serum from patients suffering from different conditions. PMID:21857974
Morello-Frosch, Rachel; Cushing, Lara J; Jesdale, Bill M; Schwartz, Jackie M; Guo, Weihong; Guo, Tan; Wang, Miaomiao; Harwani, Suhash; Petropoulou, Syrago-Styliani E; Duong, Wendy; Park, June-Soo; Petreas, Myrto; Gajek, Ryszard; Alvaran, Josephine; She, Jianwen; Dobraca, Dina; Das, Rupali; Woodruff, Tracey J
2016-11-15
Exposures to environmental pollutants in utero may increase the risk of adverse health effects. We measured the concentrations of 59 potentially harmful chemicals in 77 maternal and 65 paired umbilical cord blood samples collected in San Francisco during 2010-2011, including polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), polybrominated diphenyl ethers (PBDEs), hydroxylated PBDEs (OH-PBDEs), and perfluorinated compounds (PFCs) in serum and metals in whole blood. Consistent with previous studies, we found evidence that concentrations of mercury (Hg) and lower-brominated PBDEs were often higher in umbilical cord blood or serum than in maternal samples (median cord:maternal ratio > 1), while for most PFCs and lead (Pb), concentrations in cord blood or serum were generally equal to or lower than their maternal pair (median cord:maternal ratio ≤ 1). In contrast to the conclusions of a recent review, we found evidence that several PCBs and OCPs were also often higher in cord than maternal serum (median cord:maternal ratio > 1) when concentrations are assessed on a lipid-adjusted basis. Our findings suggest that for many chemicals, fetuses may experience higher exposures than their mothers and highlight the need to characterize potential health risks and inform policies aimed at reducing sources of exposure.
Austdal, Marie; Tangerås, Line H; Skråstad, Ragnhild B; Salvesen, Kjell; Austgulen, Rigmor; Iversen, Ann-Charlotte; Bathen, Tone F
2015-09-08
Hypertensive disorders of pregnancy, including preeclampsia, are major contributors to maternal morbidity. The goal of this study was to evaluate the potential of metabolomics to predict preeclampsia and gestational hypertension from urine and serum samples in early pregnancy, and elucidate the metabolic changes related to the diseases. Metabolic profiles were obtained by nuclear magnetic resonance spectroscopy of serum and urine samples from 599 women at medium to high risk of preeclampsia (nulliparous or previous preeclampsia/gestational hypertension). Preeclampsia developed in 26 (4.3%) and gestational hypertension in 21 (3.5%) women. Multivariate analyses of the metabolic profiles were performed to establish prediction models for the hypertensive disorders individually and combined. Urinary metabolomic profiles predicted preeclampsia and gestational hypertension at 51.3% and 40% sensitivity, respectively, at 10% false positive rate, with hippurate as the most important metabolite for the prediction. Serum metabolomic profiles predicted preeclampsia and gestational hypertension at 15% and 33% sensitivity, respectively, with increased lipid levels and an atherogenic lipid profile as most important for the prediction. Combining maternal characteristics with the urinary hippurate/creatinine level improved the prediction rates of preeclampsia in a logistic regression model. The study indicates a potential future role of clinical importance for metabolomic analysis of urine in prediction of preeclampsia.
Focant, Jean-François; Eppe, Gauthier; Massart, Anne-Cécile; Scholl, Georges; Pirard, Catherine; De Pauw, Edwin
2006-10-13
We report on the use of a state-of-the-art method for the measurement of selected polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and polychlorinated biphenyls in human serum specimens. The sample preparation procedure is based on manual small size solid-phase extraction (SPE) followed by automated clean-up and fractionation using multi-sorbent liquid chromatography columns. SPE cartridges and all clean-up columns are disposable. Samples are processed in batches of 20 units, including one blank control (BC) sample and one quality control (QC) sample. The analytical measurement is performed using gas chromatography coupled to isotope dilution high-resolution mass spectrometry. The sample throughput corresponds to one series of 20 samples per day, from sample reception to data quality cross-check and reporting, once the procedure has been started and series of samples keep being produced. Four analysts are required to ensure proper performances of the procedure. The entire procedure has been validated under International Organization for Standardization (ISO) 17025 criteria and further tested over more than 1500 unknown samples during various epidemiological studies. The method is further discussed in terms of reproducibility, efficiency and long-term stability regarding the 35 target analytes. Data related to quality control and limit of quantification (LOQ) calculations are also presented and discussed.
Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS
NASA Astrophysics Data System (ADS)
Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.
2013-09-01
Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.
[Identification of hepatitis B virus YMDD point mutation using peptide nucleic acid clamping PCR].
Zhang, Yingying; He, Haitang; Yang, Jie; Hou, Jinlin
2013-06-01
To establish a peptide nucleic acid clamping PCR assay for detecting hepatitis B virus (HBV) drug resistance mutation. RtM204I (ATT) mutant, rtM204V (GTG) mutant and rtM204 (ATG) wild-type plasmids mixed at different ratios were detected for mutations by PNA clamping PCR assay and direct sequencing, and the sensitivity and specificity of the two methods were compared. Serum samples from 85 patients with chronic HBV infection were detected for drug resistance using the two methods. The sensitivity of PNA-PCR assay was 0.001% in a 10(5)-fold excess of wild-type HBV DNA with a detection limit of 10(1) copies. The sensitivity of direct sequencing was 10% with a detection limit of 10(4) copies. Mutants were detected in 73 of the 85 serum samples (85.9%), including YIDD in 40 samples, YVDD in 23 samples, and YIDD+YVDD in 10 samples. The agreement of PNA-PCR assay with direct sequencing was only 40% (34/85, YIDD in 21 samples, YVDD in 11 samples, and YIDD+YVDD in 2 samples). Neither of the two methods yielded positive results for the negative control samples, suggesting their good specificity. PNA-PCR assay appears to be a more sensitive and rapid assay for detection of HBV genotypic resistance.
Suarez-Diez, Maria; Adam, Jonathan; Adamski, Jerzy; Chasapi, Styliani A; Luchinat, Claudio; Peters, Annette; Prehn, Cornelia; Santucci, Claudio; Spyridonidis, Alexandros; Spyroulias, Georgios A; Tenori, Leonardo; Wang-Sattler, Rui; Saccenti, Edoardo
2017-07-07
Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA-MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids.
2017-01-01
Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA–MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids. PMID:28517934
Organic cattle products: Authenticating production origin by analysis of serum mineral content.
Rodríguez-Bermúdez, Ruth; Herrero-Latorre, Carlos; López-Alonso, Marta; Losada, David E; Iglesias, Roberto; Miranda, Marta
2018-10-30
An authentication procedure for differentiating between organic and non-organic cattle production on the basis of analysis of serum samples has been developed. For this purpose, the concentrations of fourteen mineral elements (As, Cd, Co, Cr, Cu, Fe, Hg, I, Mn, Mo, Ni, Pb, Se and Zn) in 522 serum samples from cows (341 from organic farms and 181 from non-organic farms), determined by inductively coupled plasma spectrometry, were used. The chemical information provided by serum analysis was employed to construct different pattern recognition classification models that predict the origin of each sample: organic or non-organic class. Among all classification procedures considered, the best results were obtained with the decision tree C5.0, Random Forest and AdaBoost neural networks, with hit levels close to 90% for both production types. The proposed method, involving analysis of serum samples, provided rapid, accurate in vivo classification of cattle according to organic and non-organic production type. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
McClung, James P; Martini, Svein; Murphy, Nancy E; Montain, Scott J; Margolis, Lee M; Thrane, Ingjerd; Spitz, Marissa G; Blatny, Janet-Martha; Young, Andrew J; Gundersen, Yngvar; Pasiakos, Stefan M
2013-11-04
Hepcidin, a peptide that is released into the blood in response to inflammation, prevents cellular iron export and results in declines in iron status. Elevated serum and urinary levels of hepcidin have been observed in athletes following exercise, and declines in iron status have been reported following prolonged periods of training. The objective of this observational study was to characterize the effects of an occupational task, military training, on iron status, inflammation, and serum hepcidin. Volunteers (n = 21 males) included Norwegian Soldiers participating in a 7-day winter training exercise that culminated in a 3-day, 54 km ski march. Fasted blood samples were collected at baseline, on day 4 (PRE, prior to the ski march), and again on day 7 (POST, following the ski march). Samples were analyzed for hemoglobin, serum ferritin, soluble transferrin receptor (sTfR), interleukin-6 (IL-6), and serum hepcidin. Military training affected inflammation and serum hepcidin levels, as IL-6 and hepcidin concentrations increased (P < 0.05) from the baseline to POST (mean ± SD, 9.1 ± 4.9 vs. 14.5 ± 8.4 pg/mL and 6.5 ± 3.5 vs. 10.2 ± 6.9 ng/mL, respectively). Iron status was not affected by the training exercise, as sTfR levels did not change over the course of the 7-day study. Military training resulted in significant elevations in IL-6 and serum hepcidin. Future studies should strive to identify the role of hepcidin in the adaptive response to exercise, as well as countermeasures for the prevention of chronic or repeated elevations in serum hepcidin due to exercise or sustained occupational tasks which may result in longer term decrements in iron status.
Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuettler, J.; White, P.F.
Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and upmore » to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.« less
Khaksari, Maryam; Mazzoleni, Lynn R; Ruan, Chunhai; Kennedy, Robert T; Minerick, Adrienne R
2017-02-01
Tears serve as a viable diagnostic fluid with advantages including less invasive sample to collect and less complex to prepare for analysis. Several water-soluble and fat-soluble vitamins were detected and quantified in human tears and compared with blood serum levels. Samples from 15 family pairs, each pair consisting of a four-month-old infant and one parent were analyzed; vitamin concentrations were compared between tears and blood serum for individual subjects, between infants and parents, and against self-reported dietary intakes. Water-soluble vitamins B 1 , B 2 , B 3 (nicotinamide), B 5 , B 9 and fat-soluble vitamin E (α-tocopherol) were routinely detected in tears and blood serum while fat-soluble vitamin A (retinol) was detected only in blood serum. Water-soluble vitamin concentrations measured in tears and blood serum of single subjects were comparable, while higher concentrations were measured in infants compared to their parents. Fat-soluble vitamin E concentrations were lower in tears than blood serum with no significant difference between infants and parents. Serum vitamin A concentrations were higher in parents than infants. Population trends were compiled and quantified using a cross correlation factor. Strong positive correlations were found between tear and blood serum concentrations of vitamin E from infants and parents and vitamin B 3 concentrations from parents, while slight positive correlations were detected for infants B 3 and parents B 1 and B 2 concentrations. Correlations between infants and parents were found for the concentrations of B 1 , B 2 , B 3 , and E in tears, and the concentrations of B 2, A, and E in blood serum. Stronger vitamin concentration correlations were found between infants and parents for the breast-fed infants, while no significant difference was observed between breast-fed and bottle-fed infants. This work is the first to demonstrate simultaneous vitamin A, B, and E detection and to quantify correlations between vitamin concentrations in tears and blood serum. Our results suggest that tears are a viable biofluid to monitor nutritional health because they sufficiently mirror blood serum data and may enhance the speed of deficiency diagnoses. Copyright © 2016 Elsevier Ltd. All rights reserved.
Quantitating Iron in Serum Ferritin by Use of ICP-MS
NASA Technical Reports Server (NTRS)
Smith, Scott M.; Gillman, Patricia L.
2003-01-01
A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid to extract its iron content. Finally, a micronebulizer is used to inject the sample of the product of the digestion into the ICPMS for analysis of its iron content. The sensitivity of the ICP-MS is high enough to enable it to characterize samples smaller than those required in the prior method (samples can be 0.15 to 0.60 mL).
Alarmins and Clinical Outcomes After Major Abdominal Surgery-A Prospective Study.
Máca, Jan; Burša, Filip; Ševčík, Pavel; Sklienka, Peter; Burda, Michal; Holub, Michal
2017-06-01
Tissue injury causing immune response is an integral part of surgical procedure. Evaluation of the degree of surgical trauma could help to improve postoperative management and determine the clinical outcomes. We analyzed serum levels of alarmins, including S100A5, S100A6, S100A8, S100A9, S100A11, and S100A12; high-mobility group box 1; and heat-shock protein 70, after elective major abdominal surgery (n = 82). Blood samples were collected for three consecutive days after surgery. The goals were to evaluate the relationships among the serum levels of alarmins and selected surgical characteristics and to test potential of alarmins to predict the clinical outcomes. Significant, positive correlations were found for high-mobility group box 1 with the length of surgery, blood loss, and intraoperative fluid intake for all three days of blood sampling. The protein S100A8 serum levels showed positive correlations with intensive care unit length of stay, 28-day and in-hospital mortality. The protein S100A12 serum levels had significant, positive correlations with intensive care unit length of stay, 28-day mortality, and in-hospital mortality. We did not find significant differences in alarmin levels between cancer and noncancer subjects. The high-mobility group box 1 serum levels reflect the degree of surgical injury, whereas proteins S100A8 and S100A12 might be considered good predictors of major abdominal surgery morbidity and mortality.
Implementing self sustained quality control procedures in a clinical laboratory.
Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N
2013-01-01
Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.
Gong, Zhong-Ying; Lv, Gao-Peng; Gao, Li-Na; Lu, Yi; Guo, Jie; Zang, Da-Wei
2018-06-13
There are no reliable biomarkers that could evaluate the disease burden in amyotrophic lateral sclerosis (ALS). The aim of our study is to evaluate the changes in cerebrospinal fluid (CSF) and serum neurofilament subunit L (NF-L) in patients with ALS and to analyze the correlations between the levels of NF-L and clinical parameters. CSF and serum samples were obtained from 80 ALS patients and 40 controls. The levels of NF-L in CSF and serum were assessed, and disease progression parameters including duration, revised ALS Functional Rating Scale (ALSFRS-r) score, disease progression rate (DPR), upper motor neuron (UMN) score, and survival were analyzed by registered neurologists. All samples were measured using a commercial enzyme-linked immunosorbent assay. Statistical analyses were performed using Prism software. Compared to the controls, the ALS patients displayed significantly increased levels of NF-L; these values were negatively correlated with the ALSFRS-r score and positively correlated with the decrease in ALSFRS-r score, DPR, and UMN score. There was no correlation between levels of NF-L and duration. In addition, the cumulative survival rate in ALS patients with a low level of NF-L was higher than in patients with a high level of NF-L. NF-L levels increased in CSF and serum of patients with ALS. NF-L may thus be a neurodegenerative biomarker for predicting ALS severity and progression, and the survival of patients with this disease. © 2018 S. Karger AG, Basel.
Van Nguyen, Dung; Van Nguyen, Cuong; Bonsall, David; Ngo, Tue Tri; Carrique-Mas, Juan; Pham, Anh Hong; Bryant, Juliet E; Thwaites, Guy; Baker, Stephen; Woolhouse, Mark; Simmonds, Peter
2018-02-28
Rodents and bats are now widely recognised as important sources of zoonotic virus infections in other mammals, including humans. Numerous surveys have expanded our knowledge of diverse viruses in a range of rodent and bat species, including their origins, evolution, and range of hosts. In this study of pegivirus and human hepatitis-related viruses, liver and serum samples from Vietnamese rodents and bats were examined by PCR and sequencing. Nucleic acids homologous to human hepatitis B, C, E viruses were detected in liver samples of 2 (1.3%) of 157 bats, 38 (8.1%), and 14 (3%) of 470 rodents, respectively. Hepacivirus-like viruses were frequently detected (42.7%) in the bamboo rat, Rhizomys pruinosus , while pegivirus RNA was only evident in 2 (0.3%) of 638 rodent serum samples. Complete or near-complete genome sequences of HBV, HEV and pegivirus homologues closely resembled those previously reported from rodents and bats. However, complete coding region sequences of the rodent hepacivirus-like viruses substantially diverged from all of the currently classified variants and potentially represent a new species in the Hepacivirus genus. Of the viruses identified, their routes of transmission and potential to establish zoonoses remain to be determined.
Contracting with outpatient hemodialysis patients to improve adherence to treatment.
Laidlaw, J K; Beeken, J E; Whitney, F W; Reyes, A A
1999-02-01
The purpose of this study was to examine the relationship between contingency contracting and adherence to prescribed therapy in outpatient chronic hemodialysis patients. A quasi-experimental, pretest/posttest design was used. The sample included 15 hemodialysis patients, 6 in the phosphorus group and 9 in the weight-gain group. The study was conducted at an outpatient hemodialysis center in a Midwestern rural state. Specific variables investigated were interdialytic weight gains and serum phosphorus levels that reflect adherence to fluid restrictions and to taking phosphate-binding medications. Weekly interviews were conducted with each patient and content analysis of interview data was completed to identify categories related to adherence and nonadherence. Pre- and postcontract weight gains and phosphorus levels were analyzed with a paired two sample t-test. The categories related to adherence and nonadherence included physiological, psychological, environmental, locus of control/self-control/self-praise, economical, medical, knowledge deficit, health benefits, family support, and social support. Adherence to taking phosphate-binding medication responded more favorably to contingency contracting than did adherence to fluid restrictions. Chronic outpatient hemodialysis patients in the sample responded to the use of contingency contracting and developed techniques to remember to take phosphate-binding medications in order to lower serum phosphorus medications.
Serum fibroblast growth factor 23 concentrations in dogs with chronic kidney disease.
Dittmer, Keren E; Perera, Kalyani C; Elder, Peter A
2017-10-01
The aim of this study was to determine if serum fibroblast growth factor (FGF23) concentrations were increased in dogs with chronic kidney disease (CKD). Serum samples submitted to a commercial laboratory were collected over a 15-month period, 14 samples were from dogs with a history of polyuria/polydipsia, azotaemia and low urine specific gravity, 20 samples were from non-azotaemic dogs. Serum FGF23, parathyroid hormone, total calcium and phosphorus, urea and creatinine were measured. Mann-Whitney test was used to determine differences between non-azotaemic and CKD groups; a one-way ANOVA with Tukey pairwise comparisons was used to determine any differences between International Renal Interest Society stages; and regression models were used to determine predictors of International Renal Interest Society stage, serum phosphorus and FGF23 concentrations. The median serum FGF23 concentration of dogs with CKD was 5194.6pg/mL, which was significantly greater (P<0.001) than the median serum FGF23 concentration of non-azotaemic dogs (259.2pg/mL). Log serum FGF23 and age were significantly associated with IRIS stage (P=0.027 and P=0.032 respectively), while log serum phosphorus concentration (P<0.001) was significantly associated with log serum FGF23 concentration. In summary, serum FGF23 concentration is increased in dogs with CKD, and is associated with serum phosphorus concentration. This phosphatonin pathway may be a useful target for the development of future treatments to control plasma phosphorus concentrations in chronic kidney disease. Copyright © 2017 Elsevier Ltd. All rights reserved.
Serum concentrations of perfluorinated compounds (PFC) ...
Perfluorinated compounds (PFCs) have been widely used in industrial applications and consumer products. Their persistent nature and potential health impacts are of concern. Given the high cost of collecting serum samples, this study is to understand whether we can quantify PFC serum concentrations using factors extracted from questionnaire responses and indirect measurements, and whether a single serum measurement can be used to classify an individual′s exposure over a one-year period. The study population included three demographic groups: young children (2–8 years old) (N=67), parents of young children (55 years old) (N=59). PFC serum concentrations, house dust concentrations, and questionnaires were collected. The geometric mean of perfluorooctane sulfonic acid (PFOS) was highest for the older adults. In contrast, the geometric mean of perfluorooctanoic acid (PFOA) was highest for children. Serum concentrations of the parent and the child from the same family were moderately correlated (Spearman correlation (r)=0.26–0.79, p<0.05), indicating common sources within a family. For adults, age, having occupational exposure or having used fire extinguisher, frequencies of consuming butter/margarine, pork, canned meat entrées, tuna and white fish, freshwater fish, and whether they ate microwave popcorn were significantly positively associated with serum concentrations of individual PFCs. For children, residential dust
Detection of endogenous cortisol in equine tears and blood at rest and after simulated stress.
Monk, Caroline S; Hart, Kelsey A; Berghaus, Roy D; Norton, Natalie A; Moore, Phillip A; Myrna, Kathern E
2014-07-01
To determine whether cortisol is present in equine tears at rest and during simulated stress and compare tear cortisol to serum free and total cortisol. Fourteen healthy adult horses were included. Paired tear total cortisol and serum total and free cortisol concentrations were measured with ELISA, chemiluminescent immunoassay, and ultrafiltration methodology, respectively, in 10 horses at rest once daily for five consecutive days. In an additional four horses, paired tear and serum samples were collected for cortisol measurement before and after adrenocorticotropic hormone (ACTH) stimulation (cosyntropin, 1 μg/kg IV). Cortisol was detectable in equine tears at rest. Following ACTH stimulation, tear cortisol increased significantly from baseline at 60-120 min (P ≤ 0.001). Serum total and free cortisol also increased significantly at 30-180 min after ACTH stimulation (P ≤ 0.001). Both serum and tear cortisol returned to baseline concentrations by 360 min. Changes in tear cortisol were similarly associated with changes in serum total and free cortisol, although high tear cortisol concentrations suggest a portion of tear cortisol may be protein-bound. Cortisol is present in equine tears and increases in concert with serum cortisol following ACTH stimulation. Further study is needed to determine whether endogenous cortisol in tears contributes to ocular pathology. © 2013 American College of Veterinary Ophthalmologists.
Heterophile antibody interference in qualitative urine/serum hCG devices: Case report.
Patel, Khushbu K; Gronowski, Ann M
2016-06-01
This case report investigates the origin of a false positive result on a serum qualitative human chorionic gonadotropin (hCG) device. A 46-year-old woman diagnosed with chronic myeloid leukemia presented with nausea and vomiting. A qualitative serum hCG test was interpreted as positive; however, a quantitative serum hCG test was negative (<5IU/L). To further investigate this discrepancy, the sample was pretreated with heterophilic blocking reagent (HBR). Additionally, the sample was tested on other qualitative hCG devices composed of antibodies from different animal sources. Blocking reagent from an automated quantitative immunoassay was also tested for its ability to inhibit the heterophile antibody interference. The qualitative test result was negative after pretreatment with heterophilic blocking reagent. Other devices composed of antibodies from different animal sources also demonstrated mixed results with the patient's sample. Blocking reagent obtained from the automated quantitative assay inhibited the heterophile antibody interference in the patient's sample. This case demonstrates that positive serum point-of-care hCG results should be interpreted with caution and confirmed with a quantitative serum hCG immunoassay when clinical suspicion is raised. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum.
Dussart, Philippe; Labeau, Bhety; Lagathu, Gisèle; Louis, Philippe; Nunes, Marcio R T; Rodrigues, Sueli G; Storck-Herrmann, Cécile; Cesaire, Raymond; Morvan, Jacques; Flamand, Marie; Baril, Laurence
2006-11-01
We evaluated a one-step sandwich-format microplate enzyme immunoassay for detecting dengue virus NS1 antigen (Ag) in human serum by use of Platelia Dengue NS1 Ag kits (Bio-Rad Laboratories, Marnes La Coquette, France). We collected 299 serum samples from patients with dengue disease and 50 serum samples from patients not infected with dengue virus. For the 239 serum samples from patients with acute infections testing positive by reverse transcription-PCR and/or virus isolation for one of the four dengue virus serotypes, the sensitivity of the Platelia Dengue NS1 Ag kit was 88.7% (95% confidence interval, 84.0% to 92.4%). None of the serum samples from patients not infected with dengue virus tested positive with the Platelia Dengue NS1 Ag kit. A diagnostic strategy combining the Platelia Dengue NS1 Ag test for acute-phase sera and immunoglobulin M capture enzyme-linked immunosorbent assay for early-convalescent-phase sera increased sensitivity only from 88.7% to 91.9%. Thus, NS1 antigen detection with the Platelia Dengue NS1 Ag kit could be used for first-line testing for acute dengue virus infection in clinical diagnostic laboratories.
Gunnala, Vishal; Guo, Rong; Minutti, Carla; Durazo-Arvizu, Ramon; Laporte, Cynthia; Mathews, Herbert; Kliethermis, Stephanie; Bhatia, Rahul
2015-05-01
To compare serum total, serum free and salivary cortisol in critically ill children. Prospective observational cohort study. Tertiary pediatric critical care unit at Ronald McDonald Children's Hospital at Loyola University Medical Center. We enrolled 59 patients (4 weeks to 18 years of age) between January 2012 and May 2013. Thirty-four patients were included in the salivary to serum free cortisol correlational analysis. Blood and saliva samples were obtained simultaneously within 24 hours of admission between the hours of 6 AM and 12 PM. Salivary cortisol was tested by liquid chromatography/tandem mass spectrometry, serum free cortisol by liquid chromatography/tandem mass spectrometry followed by equilibrium dialysis, and serum total cortisol by liquid chromatography/tandem mass spectrometry. Salivary and serum free cortisol values from 34 patients had a correlation coefficient (r) of 0.87 (95% CI, 0.75-0.93; p < 0.0001). The total serum and salivary cortisol values had a correlation coefficient (r) of 0.67 (95% CI, 0.42-0.81; p < 0.0001). The total serum and serum free cortisol values had a correlation coefficient (r) of 0.83 (95% CI, 0.69-0.91; p < 0.0001). Serum free and salivary cortisol values correlate in critically ill children. Salivary cortisol can be used as a surrogate for serum free cortisol in critically ill pediatric patients. Salivary cortisol is a cost-effective and less invasive measure of bioavailable cortisol and offers an alternate and accurate method for assessing critical illness-related corticosteroid insufficiency in children.
Garca, Mehmet Fatih; Demir, Halit; Turan, Mahfuz; Bozan, Nazım; Kozan, Ahmet; Belli, Şeyda Bayel; Arslan, Ayşe; Cankaya, Hakan
2014-06-01
To emphasize the effectiveness of adenosine deaminase (ADA) enzyme, which has important roles in the differentiation of lymphoid cells, and oxidative stress in patients with chronic tonsillitis. Serum and tissue samples were obtained from 25 patients who underwent tonsillectomy due to recurrent episodes of acute tonsillitis. In the control group, which also had 25 subjects, only serum samples were taken as obtaining tissue samples would not have been ethically appropriate. ADA enzyme activity, catalase (CAT), carbonic anhydrase (CA), nitric oxide (NO) and malondialdehyde (MDA) were measured in the serum and tissue samples of patients and control group subjects. The serum values of both groups were compared. In addition, the tissue and serum values of patients were compared. Serum ADA activity and the oxidant enzymes MDA and NO values of the patient group were significantly higher than those of the control group (p < 0.001), the antioxidant enzymes CA and CAT values of the patient group were significantly lower than those of the control group (p < 0.001). In addition, while CA, CAT and NO enzyme levels were found to be significantly higher in the tonsil tissue of the patient group when compared to serum levels (p < 0.05), there was no difference between tissue and serum MDA and ADA activity (p > 0.05). Elevated ADA activity may be effective in the pathogenesis of chronic tonsillitis both by impairing tissue structure and contributing to SOR formation.
Sá e Silva, Mariana; Swayne, David E
2012-09-01
Surveillance for low pathogenicity avian influenza virus (LPAIV) infections has primarily relied on labor-intensive collection and serological testing of serum, but for many poultry diseases, easier-to-collect yolk samples have replaced serum for surveillance testing. A time-course LPAIV infection study in layers was performed to evaluate the utility of antibody detection in serum vs. egg yolk samples. Layers inoculated with the LPAIV A/Bobwhite Quail/Pennsylvania/20304/98 (H7N2) were tested for antibody levels in the serum and egg yolk by using the agar gel immunodiffusion test (AGID), hemagglutination-inhibition test (HI), and a commercially available enzyme-linked immunosorbent assay (ELISA). Anti-influenza specific antibodies were detected in the serum as early as 7 days postinoculation (DPI), and the majority of the hens remained positive until 42 DPI. Antibodies in the egg yolk were first detected by AGID at 7 DPI, which was also the first day of detection in serum. However, the majority of the eggs were positive by all techniques at 11 DPI and remained positive until 42 DPI, at which time the number of AGID+ and HI+ samples declined slightly as compared to ELISA+ samples. These results suggest that egg yolk can be an alternative to serum for flock serological surveillance against LPAIV infections, and the three methods (AGID, HI, and ELISA) will give similar results for first 42 days after infection, although AGID may give earlier positive response.
Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo
2016-09-07
Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.
A new approach for rapid detection and typing of serum monoclonal components.
Cacoub, P; Camproux, A C; Thiolières, J M; Assogba, U; Hausfater, P; Mallet, A; Foglietti, M J; Piette, J C; Bernard, M
2000-12-01
When used independently, none of the routine methods to explore serum monoclonal components (MC), including: serum protein electrophoresis (SPE), immunoelectrophoresis (IEP), kappa to lambda ratio (KLR) and immunofixation (IFE), provides a comprehensive quantitative and qualitative identification of the MC. In the past few years the concept of 'protein profile', based on immunonephelometric quantifications of serum proteins, has become widely used. It consists of a qualitative and quantitative graphic representation of numerous serum proteins including immunoglobulins. Aim of study was to develop a multidimensional model based exclusively on protein profiles labeled the protein profile prediction method (PPPM) to improve routine MC detection and typing. Serum samples from 127 hospitalized patients and 99 healthy blood donors were submitted to all of the following: SPE, IFE, KLR and a protein profile (which included IgM, IgA, IgG, kappa and lambda chain detections and quantification). The presence of a MC using IFE was chosen as the gold standard. Healthy donors and patients were randomly divided into two groups defined as testing and validation groups. A logistic model was designed based on the protein profiles of the testing group leading to the determination of a threshold value (called Z(r)) for MC detection. It was then tested to detect MC in the validation group. Using IFE, 73 MC were found in the 127 hospitalized patients. Using the threshold value for MC detection of Z(r)=1.86, the PPPM showed greater sensitivity (94.6%) in detecting a MC compared to either SPE (64.8%) or KLR (89.2%). This result was obtained without diminished specificity (80.8%). The association of SPE or KLR to PPPM did not significantly increase the sensitivity of the PPPM. In the validation group, for samples which had a high predictive probability of a MC using PPPM, the correct MC typing was identified in up to 77% of sera using PPPM only. These results may be interesting in helping to determine when supplementary IFE analysis is required to qualitatively analyze a MC. PPPM allows MC detection with great sensitivity. The immune protein profile dramatically increases the sensitivity of either SPE and/or KLR in detecting MC and may also allow heavy and light chain typing.
Serum ischemia modified albumin is a possible new marker of oxidative stress in phenylketonuria.
Keshavarzi, Fatemeh; Rastegar, Mohsen; Vessal, Mahmood; Rafiei Dehbidi, Gholamreza; Khorsand, Marjan; Ganjkarimi, Amir Hossein; Takhshid, Mohammad Ali
2018-06-01
The role of oxidative stress in the pathogenesis of phenylketonuria (PKU)-associated disorders has been implicated. Ischemia modified albumin (IMA) is a modified form of serum albumin, which is produced under the conditions of oxidative stress. The aim of this study was to measure the serum level of IMA in the PKU patients and to investigate its ability in predicting the status of oxidative stress in these patients. Fifty treated-PKU patients and fifty age- and sex-matched healthy subjects were included in the study. The blood samples were obtained and the serum level of phenylalanine (Phe) was measured using reverse phase HPLC method. The levels of IMA, malondialdehyde (MDA), gamma-glutamyl transferase (GGT) activity, and uric acid (UA) were determined using colorimetric methods. The levels of serum Phe, IMA, and MDA were significantly higher (p < 0.001) and the level of UA (p < 0.05) was lower in the PKU patients compared to control group. Serum IMA level was positively correlated with MDA (r = 0.585, p < 0.001) and UA (r = 0.6, p < 0.001). An inverse relationship was observed between the serum level of IMA and Phe (r = - 0.410, p < 0. 01). Results of the present study suggest that serum IMA level could be used as a novel marker for the evaluation of oxidative stress in the PKU patients.
Sia, I G; Wilson, J A; Espy, M J; Paya, C V; Smith, T F
2000-02-01
Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients.
Sia, Irene G.; Wilson, Jennie A.; Espy, Mark J.; Paya, Carlos V.; Smith, Thomas F.
2000-01-01
Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients. PMID:10655353
Bakken, L L; Callister, S M; Wand, P J; Schell, R F
1997-01-01
In 1991, we reported that 55% of laboratories participating in the Wisconsin Proficiency Testing Program could not accurately identify serum samples from Lyme disease patients containing antibody against Borrelia burgdorferi. The purpose of this study was to determine whether the accuracy of Lyme disease test results reported by approximately 500 participants in the Wisconsin State Laboratory of Hygiene/College of American Pathologists Lyme Disease Survey had improved. From 1992 through 1994, 50 serum samples were sent to participants of the survey. Each laboratory received 28 serum samples from individuals with Lyme disease according to the case definition of the Centers for Disease Control and Prevention and 22 serum samples from healthy individuals. Unfortunately, the serodiagnosis of Lyme disease by participants had not improved. The specificity of the Lyme disease assays steadily decreased from approximately 95% to approximately 81% during the 3-year period of the survey. False-positive test results approached 55% with some of the serum samples from healthy donors. A serum sample containing antibody against Treponema pallidum was reported as positive by 70% of the participants. In addition, the sensitivity fluctuated between 93 and 75%, depending upon the conjugate used by the laboratories. These results suggest that stronger criteria must be applied for approving and continuing to approve commercially available kits for the serodiagnosis of Lyme disease. PMID:9041384
Tinkov, Alexey A; Skalnaya, Margarita G; Demidov, Vasily A; Serebryansky, Eugeny P; Nikonorov, Alexandr A; Skalny, Anatoly V
2014-12-01
The primary objective of the research is to estimate the dependence between hair mercury content, hair selenium, mercury-to-selenium ratio, serum lipid spectrum, and gamma-glutamyl transferase (GGT) activity in 63 adults (40 men and 23 women). Serum triglyceride (TG) concentration in the high-mercury group significantly exceeded the values obtained for low- and medium-mercury groups by 72 and 42 %, respectively. Serum GGT activity in the examinees from high-Hg group significantly exceeded the values of the first and the second groups by 75 and 28 %, respectively. Statistical analysis of the male sample revealed similar dependences. Surprisingly, no significant changes in the parameters analyzed were detected in the female sample. In all analyzed samples, hair mercury was not associated with hair selenium concentrations. Significant correlation between hair mercury content and serum TG concentration (r = 0.531) and GGT activity (r = 0.524) in the general sample of the examinees was detected. The respective correlations were observed in the male sample. Hair mercury-to-selenium ratios significantly correlated with body weight (r = 0.310), body mass index (r = 0.250), serum TG (r = 0.389), atherogenic index (r = 0.257), and GGT activity (r = 0.393). The same correlations were observed in the male sample. Hg/Se ratio in women did not correlate with the analyzed parameters. Generally, the results of the current study show the following: (1) hair mercury is associated with serum TG concentration and GGT activity in men, (2) hair selenium content is not related to hair mercury concentration, and (3) mercury-to-selenium ratio correlates with lipid spectrum parameters and GGT activity.
Burns, J; Hou, S; Riley, C B; Shaw, R A; Jewett, N; McClure, J T
2014-01-01
Rapid, economical, and quantitative assays for measurement of camelid serum immunoglobulin G (IgG) are limited. In camelids, failure of transfer of maternal immunoglobulins has a reported prevalence of up to 20.5%. An accurate method for quantifying serum IgG concentrations is required. To develop an infrared spectroscopy-based assay for measurement of alpaca serum IgG and compare its performance to the reference standard radial immunodiffusion (RID) assay. One hundred and seventy-five privately owned, healthy alpacas. Eighty-two serum samples were collected as convenience samples during routine herd visits whereas 93 samples were recruited from a separate study. Serum IgG concentrations were determined by RID assays and midinfrared spectra were collected for each sample. Fifty samples were set aside as the test set and the remaining 125 training samples were employed to build a calibration model using partial least squares (PLS) regression with Monte Carlo cross validation to determine the optimum number of PLS factors. The predictive performance of the calibration model was evaluated by the test set. Correlation coefficients for the IR-based assay were 0.93 and 0.87, respectively, for the entire data set and test set. Sensitivity in the diagnosis of failure of transfer of passive immunity (FTPI) ([IgG] <1,000 mg/dL) was 71.4% and specificity was 100% for the IR-based method (test set) as gauged relative to the RID reference method assay. This study indicated that infrared spectroscopy, in combination with chemometrics, is an effective method for measurement of IgG in alpaca serum. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Salgado, Miguel; Kruze, Juan; Collins, Michael T
2007-01-01
Fecal culture has been the primary method used to diagnose paratuberculosis in goats. It is laborious, slow, and expensive. Validation of enzyme-linked immunosorbent assays (ELISAs) on milk samples could make paratuberculosis testing more widely available for goat farmers. The aim of this study was to determine the accuracy of serum and milk ELISAs for paratuberculosis, relative to fecal culture, in Chilean dairy goats. Eight dairy goat herds were selected. Feces, blood, and milk samples were collected from all female goats >2 years old. Fecal samples were cultured using Herrold egg yolk medium with mycobactin J and antibiotics. Serum and milk samples were tested using a commercial ELISA kit for Mycobacterium avium subsp. paratuberculosis antibody detection. A total of 383 goats were tested by ELISA and fecal culture. The sensitivity of ELISA on serum and milk relative to fecal culture was 74.3% (95% CI: 59.8-88.8) and 60% (95% CI: 43.8-76.2), respectively. The corresponding values for ELISA specificity based on the percentage of non- M. avium subsp. paratuberculosis-infected goats testing ELISA-negative were 98.6% (95% CI: 96.6-100) and 99.3% (95% CI: 97.9-100) on serum and milk, respectively. Proportions of positive results for serum and fecal samples were significantly different, whereas the proportions of positive results for milk and fecal samples were not significantly different. The milk ELISA had a moderate level of agreement with fecal culture results (Kappa = 0.57). The paratuberculosis ELISA on goat milk samples may be a cost-effective, accurate alternative to fecal culture.
Wu, Kusheng; Xu, Xijin; Peng, Lin; Liu, Junxiao; Guo, Yongyong; Huo, Xia
2012-11-01
Perfluorooctanoic acid (PFOA) has applications in numerous industrial and consumer products. The widespread prevalence of PFOA in humans demonstrated in recent studies has drawn considerable interest from the public. We aimed to evaluate the exposure of mothers to PFOA and the potential hazards to neonates in a primitive electronic waste recycling area, Guiyu, China, and a control area, Chaonan, China. Our investigation included analyses of maternal serum samples, health effect examinations, and other relevant factors. Questionnaires were administered and maternal serum samples were collected for 167 pregnant women. Solid phase extraction method was used for all analytical sample preparation, and analyses were completed using high performance liquid chromatography tandem mass spectrometry method. The PFOA concentration was higher in maternal serum samples from Guiyu than in samples from Chaonan (median 16.95, range 5.5-58.5 ng mL(-1); vs. 8.7, range 4.4-30.0 ng mL(-1); P<0.001). Residence in Guiyu, involvement in e-waste recycling, husband's involvement in e-waste and use of the family residence as workshop were significant factors contributing to PFOA exposure. Maternal PFOA concentrations were significantly different between normal births and adverse birth outcomes including premature delivery, term low birth weight, and stillbirths. After adjusting for potential confounders, PFOA was negatively associated with gestational age [per lg-unit: β=-15.99 days, 95% confidence interval (CI), -27.72 to -4.25], birth weight (per lg-unit: β=-267.3g, 95% CI, -573.27 to -37.18), birth length (per lg-unit: β=-1.91 cm, 95% CI, -3.31 to -0.52), and Apgar scores (per lg-unit: β=-1.37, 95% CI, -2.42 to -0.32), but not associated with ponderal index. Mothers from Guiyu were exposed to higher levels of PFOA than those from control areas. Prenatal exposure to PFOA was associated with decreased neonatal physical development and adverse birth outcomes. Copyright © 2012 Elsevier Ltd. All rights reserved.
Wilberger, M S; McKenzie, E C; Payton, M E; Rigas, J D; Valberg, S J
2015-03-01
Exertional rhabdomyolysis (ER) is a reported syndrome in competing endurance horses; however, the prevalence and cause of ER in this population have not been defined. To determine the prevalence of ER in a sample of endurance racing horses and investigate factors, including relevant genetic defects, contributing to the occurrence of rhabdomyolysis in this group. Prospective clinical study. Riders of 101 horses participating in one of four 50-mile (80.5 km) distance races completed a comprehensive questionnaire regarding the medical history, management and performance of their horse. Serum creatine kinase activity (CK) was measured before and 4 h after completion of exercise. Hair samples were analysed by PCR for the R309H mutation in the glycogen synthase gene (GYS1) responsible for type 1 polysaccharide storage myopathy (PSSM) and the C7360G mutation in the ryanodine receptor 1 (RYR1) gene causing malignant hyperthermia (MH). Samples were obtained from 68 Arabians, 20 half-Arabians and 13 horses of other breeds. Serum CK was above the resting reference interval (145-633 u/l) in 38 horses after racing (median 883 u/l, range 658-3739) but was compatible with values previously reported in apparently healthy endurance horses. Pathological ER was suspected to occur in 4 horses with serum CK activities exceeding 10,000 u/l 4 h after racing (median 84,825 u/l; range 10,846-381,790) including 3 Arabians and one half-Arabian horse. GYS1 and RYR1 mutations were not present in hair samples from any horses. Exertional rhabdomyolysis occurred at a prevalence of 4.0% in a sample of horses participating in 50 mile distance events and all affected horses were Arabian or half-Arabian. The cause of ER in the endurance horse population remains unknown; however, ER in competing Arabian endurance horses is unlikely to be due to type 1 PSSM or MH. © 2014 EVJ Ltd.
Wang, Jun-Sing; Lee, Wen-Jane; Lee, I-Te; Lin, Shih-Yi; Lee, Wen-Lieng; Liang, Kae-Woei; Lin, Shing-Jong; Sheu, Wayne Huey-Herng
2018-05-26
We aimed to investigate the association of serum aryl hydrocarbon receptor (AhR) levels with insulin resistance and β-cell function in patients undergoing coronary angiography with no history of diabetes. Patients with no history of diabetes who had been admitted for coronary angiography were enrolled. An oral glucose tolerance test (OGTT) was conducted two to four weeks after the patients were discharged from the hospital, and a blood sample was collected for measurements of glucose, insulin, and AhR. Patients' glucose regulation status was determined using the results of OGTT. Insulin resistance was assessed using the homeostasis model assessment method (HOMA-IR). β-cell function was assessed using the insulinogenic index (IGI). A total of 473 patients were included in the analysis (mean age 61 ± 12 years, male 81.8%, mean body mass index 26.1 ± 3.6 kg/m 2 ). Overall, mean serum AhR level was 25.1 ± 12.2 pg/ml. Patients with normal glucose tolerance had a lower serum AhR level (23.4 ± 10.8 pg/ml) than those who had prediabetes (26.2 ± 13.2 pg/ml) or newly diagnosed diabetes (26.9 ± 12.3 pg/ml, p=0.029). Using linear regression analysis, serum AhR levels were not associated with HOMA-IR. In contrast, serum AhR levels were negatively associated with IGI after adjustment for several confounders including HOMA-IR (β coefficient -0.162, 95% CI -0.302 to -0.022, p=0.023). In patients with no history of diabetes, levels of serum AhR were negatively associated with β-cell function, independent of several confounders including insulin resistance. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Stevens, Servi J. C.; Pronk, Inge; Middeldorp, Jaap M.
2001-01-01
Epstein-Barr virus (EBV) DNA load monitoring in peripheral blood has been shown to be a useful tool for the diagnosis of aberrant EBV infections. In the present study we compared the relative diagnostic values of EBV DNA load monitoring in unfractionated whole blood and simultaneously obtained serum or plasma samples from Burkitt's lymphoma (BL) patients, transplant recipients, human immunodeficiency virus (HIV)-infected individuals, and infectious mononucleosis (IM) patients by a quantitative competitive PCR (Q-PCR). The EBV DNA load in BL patients was mainly situated in the cellular blood compartment (up to 4.5 × 106 copies/ml). EBV DNA loads in unfractionated whole blood and parallel serum samples showed no correlation. In transplant recipients, IM patients, and HIV-infected patients, the EBV burden in the circulation was almost exclusively restricted to the cellular blood compartment, because serum or plasma samples from these patients yielded negative results by Q-PCR, despite high viral loads in corresponding whole-blood samples. A 10-fold more sensitive but qualitative BamHI-W-repeat PCR occasionally revealed the presence of EBV at <2,000 copies of EBV DNA per ml of serum. Spiking of 100 copies of EBV DNA in samples with negative Q-PCR results excluded the presence of inhibitory factors in serum or plasma that influenced the Q-PCR result. Serum samples from all populations were often positive for β-globin DNA, indicating cell damage in vivo or during serum preparation. We conclude that serum is an undesirable clinical specimen for EBV DNA load monitoring because it omits the presence of cell-associated virus and uncontrolled cell lysis may give irreproducible results or overestimation of the DNA load. Unfractionated whole blood is strongly preferred since it combines all blood compartments that may harbor EBV and it best reflects the absolute viral burden in the patient's circulation. PMID:11283029
Mohammadpour, Niloofar; Saki, Jasem; Rafiei, Abdollah; Khodadadi, Ali; Tavalla, Mehdi; Cheraghian, Bahman
2016-10-01
Toxoplasma gondii is one of the most common causes of latent infections in humans worldwide. Detecting anti- Toxoplasma antibodies in serum using serological tests is a common method to diagnose toxoplasmosis. In the present study, an indigenous ELISA kit was prepared using tachyzoites from the RH strain of T. gondii , and its sensitivity and specificity were compared with those of commercial kits. To produce antigens, 0.02 mL of locally isolated T. gondii RH strain parasites along with 10 9 tachyzoites were injected into the peritoneal cavities of 50 laboratory mice (BALB/C). Parasites were collected after 4 days. After filtering and washing, the concentration of protein in sonicated tachyzoites was calculated using the Lowry protein assay. The dilution of antigen, serum and alkaline phosphatase conjugate was assessed in designing an indigenous ELISA method; then ELISA was performed based on these dilutions, and its sensitivity was determined using 200 serum samples. In addition, the specificity of the assay was evaluated using 40 serum samples from patients with tuberculosis, leukemia or hydatid cyst. Indigenous ELISA was used to examine 100 serum samples containing anti- T. gondii IgG, with a sensitivity of 98% (commercial kits: 100%). Another 100 serum samples containing anti- T. gondii IgM were also tested, with a sensitivity of 99% (commercial kits: 100%). When 40 serum samples from patients with leukemia, hydatid cyst or tuberculosis were examined using anti- T. gondii IgG, the specificity was 100%, identical to commercial kits. However, the specificity of a similar test with anti- T. gondii IgM was just 28.6% for serum samples from leukemia patients, 21.4% for hydatid cyst and 16.7% for tuberculosis. We found that purified locally isolated soluble crude antigens of the RH strain of T. gondii from the peritoneal cavity of mice may be one of the most promising antigens for detection of human toxoplasmosis in routine screening.
Karlberg, Helen; Sharifi-Mood, Batool; Mousavi-Jazi, Mehrdad; Dilcher, Meik; Lindegren, Gunnel; Mardani, Masoud; Bereskly, Sandor; Weidmann, Manfred; Mirazimi, Ali
2015-04-01
Crimean-Congo hemorrhagic fever (CCHF) is an arthropod-borne disease of humans associated with a severe clinical picture, including hemorrhagic syndrome and a high mortality rate. CCHF virus is widely distributed throughout large areas of the world. To characterize the serological status in CCHF patients, paired clinical samples were collected from suspected CCHF patients and analyzed by microbiological and other laboratory analyses with the aim of: determining the presence of neutralizing antibodies against CCHF virus; investigating the cross-reactivity of these neutralizing antibodies against virus isolated from the same outbreak and against other available laboratory strain; and studying the relationship between the isolated virus with other virus by whole genome sequencing. Patients at Boo-Ali Hospital, Zahedan, Iran, with clinical symptoms ranging from mild to severe hemorrhagic fever were included in the study. Two serum samples were taken from each patient, the first as soon as the patient matched the criteria for CCHF notification and the second when the patient was discharged from hospital (2 weeks later). Commercial and in-house assays revealed a positive IgM signal in acute serum samples from six patients. A novel finding was that CCHF patients develop neutralizing antibodies soon after infection. Interestingly these antibodies were able to neutralize other CCHF virus strains too. The complete sequence of the Zahedan 2007 isolate, including the hitherto unknown first L-segment sequence, was identified using an original clinical sample from one patient with confirmed CCHF infection. © 2015 Wiley Periodicals, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... either electronic or written comments on the collection of information by October 1, 2013. ADDRESSES: Submit electronic comments on the collection of information to http://www.regulations.gov . Submit... detecting antibodies to T. cruzi in plasma and serum samples from individual human donors, including donors...
Knauf, Sascha; Dahlmann, Franziska; Batamuzi, Emmanuel K; Frischmann, Sieghard; Liu, Hsi
2015-03-01
There is evidence to suggest that the yaws bacterium (Treponema pallidum ssp. pertenue) may exist in non-human primate populations residing in regions where yaws is endemic in humans. Especially in light of the fact that the World Health Organizaiton (WHO) recently launched its second yaws eradication campaign, there is a considerable need for reliable tools to identify treponemal infection in our closest relatives, African monkeys and great apes. It was hypothesized that commercially available serological tests detect simian anti-T. pallidum antibody in serum samples of baboons, with comparable sensitivity and specificity to their results on human sera. Test performances of five different treponemal tests (TTs) and two non-treponemal tests (NTTs) were evaluated using serum samples of 57 naturally T. pallidum-infected olive baboons (Papio anubis) from Lake Manyara National Park in Tanzania. The T. pallidum particle agglutination assay (TP-PA) was used as a gold standard for comparison. In addition, the overall infection status of the animals was used to further validate test performances. For most accurate results, only samples that originated from baboons of known infection status, as verified in a previous study by clinical inspection, PCR and immunohistochemistry, were included. All tests, TTs and NTTs, used in this study were able to reliably detect antibodies against T. pallidum in serum samples of infected baboons. The sensitivity of TTs ranged from 97.7-100%, while specificity was between 88.0-100.0%. The two NTTs detected anti-lipoidal antibodies in serum samples of infected baboons with a sensitivity of 83.3% whereas specificity was 100%. For screening purposes, the TT Espline TP provided the highest sensitivity and specificity and at the same time provided the most suitable format for use in the field. The enzyme immune assay Mastblot TP (IgG), however, could be considered as a confirmatory test.
NASA Astrophysics Data System (ADS)
Hernández-Caraballo, Edwin A.; Burguera, Marcela; Burguera, José L.
2002-12-01
A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH 4OH+0.05% w/v Triton X-100 ®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO 3) 2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1 -1 Se, corresponding to 30 μg l -1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l -1, with a mean value of 114±22 μg l -1.
NASA Astrophysics Data System (ADS)
Li, S. X.; Zhang, Y. J.; Zeng, Q. Y.; Li, L. F.; Guo, Z. Y.; Liu, Z. M.; Xiong, H. L.; Liu, S. H.
2014-06-01
Cancer is the most common disease to threaten human health. The ability to screen individuals with malignant tumours with only a blood sample would be greatly advantageous to early diagnosis and intervention. This study explores the possibility of discriminating between cancer patients and normal subjects with serum surface-enhanced Raman spectroscopy (SERS) and a support vector machine (SVM) through a peripheral blood sample. A total of 130 blood samples were obtained from patients with liver cancer, colonic cancer, esophageal cancer, nasopharyngeal cancer, gastric cancer, as well as 113 blood samples from normal volunteers. Several diagnostic models were built with the serum SERS spectra using SVM and principal component analysis (PCA) techniques. The results show that a diagnostic accuracy of 85.5% is acquired with a PCA algorithm, while a diagnostic accuracy of 95.8% is obtained using radial basis function (RBF), PCA-SVM methods. The results prove that a RBF kernel PCA-SVM technique is superior to PCA and conventional SVM (C-SVM) algorithms in classification serum SERS spectra. The study demonstrates that serum SERS, in combination with SVM techniques, has great potential for screening cancerous patients with any solid malignant tumour through a peripheral blood sample.
Kramer, Marabeth M; Hirota, Jeremy A; Sood, Akshay; Teschke, Kay; Carlsten, Christopher
2017-04-01
Adipokines are mediators released from adipose tissue. These proteins are regarded as active elements of systemic and pulmonary inflammation, whose dysregulation can alter an individual's risk of developing allergic lung diseases. Despite this knowledge, adipokine responses to inhaled stimuli are poorly understood. We sought to measure serum and lung adiponectin, leptin, and resistin in an atopic adult study population following exposure to allergen and diesel exhaust (DE). Two types of lung samples including bronchoalveolar lavage (BAL) and bronchial wash (BW), and a time course of serum samples, were collected from the 18 subjects who participated in the randomized, double-blinded controlled human study. The two crossover exposure triads in this study were inhaled DE and filtered air each followed by instilled allergen or saline. Serum and lung adipokine responses to these exposures were quantified using enzyme-linked immunosorbent assay. Allergen significantly increased adiponectin and leptin in BAL, and adiponectin in the BW 48 hours after exposure. Serum leptin and resistin responses were not differentially affected by exposure, but varied over time. Coexposure with DE and allergen revealed significant correlations between the adiponectin/leptin ratio and FEV 1 changes and airway responsiveness measures. Changes in lung and serum adipokines in response to allergen exposure were identified in the context of a controlled exposure study. Coexposure identified a potentially protective role of adiponectin in the lung. This response was not observed in those with baseline airway hyper-responsiveness, or after allergen exposure alone. The clinical relevance of this potentially adaptive adipokine pattern warrants further study. Copyright © 2016 Elsevier Inc. All rights reserved.
Rollin, E; Berghaus, R D; Rapnicki, P; Godden, S M; Overton, M W
2010-03-01
The objective of this study was to determine the effect of an injection of 10% butaphosphan and cyanocobalamin (Catosal, Bayer, Shawnee Mission, KS) on the day of calving and 1 d later on the prevalence of subclinical ketosis in dairy cattle in the early postpartum period. Cows from 4 herds (n=1,122) were randomized to receive either 25mL of 10% butaphosphan and cyanocobalamin or 25mL of sterile water subcutaneously on both days. Each milliliter of Catosal contained 0.05mg of cyanocobalamin and 100mg of butaphosphan, which provided 17.3mg of P in the form of [1-(butylamino)-1-methylethyl]-phosphonic acid. Serum was sampled for beta-hydroxybutyrate (BHBA) concentration at calving (pretreatment) and again between 3 and 10 d in milk. A subset of samples from mature cows was also evaluated for serum Ca and P concentrations. When cows from all age groups were included in the analysis, there was no difference between the median serum BHBA concentrations of cows in the 2 treatment groups, and no difference in the proportion of hyperketonemic cows (serum BHBA >or=1,200micromol/L) during the first week postpartum. When the analysis was restricted to mature cows (lactation >or=3), both the median BHBA concentration and the proportion of hyperketonemic cows were significantly lower in the treatment group than in the placebo group. Serum Ca and P concentrations did not differ between treatment groups. Our results suggest that injection of butaphosphan and cyanocobalamin on the day of calving and 1 d later may decrease the prevalence of subclinical ketosis during the week after calving in mature dairy cows, but not in first- and second-lactation animals.
Gupta, Shreya; Deoskar, Anuradha; Gupta, Puneet; Jain, Sandhya
2015-01-01
OBJECTIVE: The aim of this cross sectional study was to assess serum insulin-like growth factor-1 (IGF-1) levels in female and male subjects at various cervical vertebral maturation (CVM) stages. MATERIAL AND METHODS: The study sample consisted of 60 subjects, 30 females and 30 males, in the age range of 8-23 years. For all subjects, serum IGF-1 level was estimated from blood samples by means of chemiluminescence immunoassay (CLIA). CVM was assessed on lateral cephalograms using the method described by Baccetti. Serum IGF-1 level and cervical staging data of 30 female subjects were included and taken from records of a previous study. Data were analyzed by Kruska-Wallis and Mann Whitney test. Bonferroni correction was carried out and alpha value was set at 0.003. RESULTS: Peak value of serum IGF-1 was observed in cervical stages CS3 in females and CS4 in males. Differences between males and females were observed in mean values of IGF-1 at stages CS3, 4 and 5. The highest mean IGF-1 levels in males was observed in CS4 followed by CS5 and third highest in CS3; whereas in females the highest mean IGF-1 levelswas observed in CS3 followed by CS4 and third highest in CS5. Trends of IGF-1 in relation to the cervical stages also differed between males and females. The greatest mean serum IGF-1 value for both sexes was comparable, for females (397 ng/ml) values were slightly higher than in males (394.8 ng/ml). CONCLUSIONS: Males and females showed differences in IGF-1 trends and levels at different cervical stages. PMID:25992990
Gupta, Shreya; Deoskar, Anuradha; Gupta, Puneet; Jain, Sandhya
2015-01-01
The aim of this cross sectional study was to assess serum insulin-like growth factor-1 (IGF-1) levels in female and male subjects at various cervical vertebral maturation (CVM) stages. The study sample consisted of 60 subjects, 30 females and 30 males, in the age range of 8-23 years. For all subjects, serum IGF-1 level was estimated from blood samples by means of chemiluminescence immunoassay (CLIA). CVM was assessed on lateral cephalograms using the method described by Baccetti. Serum IGF-1 level and cervical staging data of 30 female subjects were included and taken from records of a previous study. Data were analyzed by Kruska-Wallis and Mann Whitney test. Bonferroni correction was carried out and alpha value was set at 0.003. Peak value of serum IGF-1 was observed in cervical stages CS3 in females and CS4 in males. Differences between males and females were observed in mean values of IGF-1 at stages CS3, 4 and 5. The highest mean IGF-1 levels in males was observed in CS4 followed by CS5 and third highest in CS3; whereas in females the highest mean IGF-1 levelswas observed in CS3 followed by CS4 and third highest in CS5. Trends of IGF-1 in relation to the cervical stages also differed between males and females. The greatest mean serum IGF-1 value for both sexes was comparable, for females (397 ng/ml) values were slightly higher than in males (394.8 ng/ml). Males and females showed differences in IGF-1 trends and levels at different cervical stages.
Antioxidant capacity and oxygen radical diseases in the preterm newborn.
Rogers, S; Witz, G; Anwar, M; Hiatt, M; Hegyi, T
2000-06-01
Bronchopulmonary dysplasia, intraventricular hemorrhage, necrotizing enterocolitis, and retinopathy of prematurity may be different manifestations of oxygen radical diseases of prematurity (ORDP). To test the hypothesis that the antioxidant capacity of cord blood serum will predict risk of ORDP. An inception cohort of premature neonates was followed up from birth until discharge or death to determine if outcome was related to cord blood serum antioxidant capacity, as determined by a manual assay measuring the relative inhibition of oxidation of 2,2'-azino-di-(3-ethylbenzthiazoline)-6 sulfonic acid (ABTS). Possible correlations between antioxidant capacity and various perinatal factors were also tested. Level 3 newborn intensive care unit. All inborn very low-birth-weight neonates from whom cord blood was available and for whom maternal consent was obtained were included. Newborns who died in the first week of life or who had major congenital malformations were excluded. A convenience sample of newborns weighing more than 1500 g was used to perfect assay and explore confounders. Significant ORDP was defined as the presence of intraventricular hemorrhage greater than grade 2, retinopathy of prematurity greater than stage 1, bronchopulmonary dysplasia at the postconceptional age of 36 weeks, or necrotizing enterocolitis with the hypothesis that neonates with ORDP will have lower antioxidant capacity in cord blood serum. Serum antioxidant capacity at birth correlated with gestational age for the entire sample of 41 neonates and for the 26 neonates born before 32 weeks' gestation. After correction for gestational age, cord serum antioxidant capacity did not correlate with maternal smoking, preeclampsia, chorioamnionitis, cord pH Apgar scores, or any of the ORDP studied. Cord serum antioxidant capacity correlates with gestational age but does not predict ORDP risk.
Lee, Young Ah; Kim, Jin Hee; Jung, Hae Woon; Lim, Youn-Hee; Bae, Sanghyuk; Kho, Younglim; Hong, Yun-Chul; Shin, Choong Ho; Yang, Sei Won
2018-07-01
The relationship between the serum concentrations of perfluoroalkyl compounds (PFCs) and growth parameters was investigated in 2-year-old Korean children. The study included 361 children aged 2years (192 boys and 169 girls; 22-27months), born at term appropriate-for-gestational-age, who visited between 2012 and 2013. Growth parameters of height and weight, and serum samples were collected from 2-year-old children. Four PFCs (perfluorohexane sulfonic acid [PFHxS], perfluorooctane sulfonic acid [PFOS], perfluorooctanoic acid [PFOA], and perfluorononanoic acid [PFNA]), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), and perfluoroheptanoic acid (PFHpA) were detected in >99, 93.4, 89.8, and 74.2% of the serum samples, respectively. The duration of breastfeeding was positively associated with the serum concentrations of ln-transformed PFHxS, PFOS, PFHpA, PFOA, PFNA, PFDA, and PFUnDA (all P<0.001). Height at 2years of age was inversely related to PFHxS, PFOS, PFOA, PFNA, and PFDA concentrations (adjusted β per ln unit [95% confidence interval, CI]: -0.84 [-1.26, -0.42], -0.77 [-1.27, -0.15], -0.91 [-1.36, -0.47], -0.48 [-1.40, -0.51], and -0.44 [-0.77, -0.10] cm, respectively), after adjusting for age, sex, and midparental height. Weight at 2years of age was inversely associated with PFNA (adjusted β per ln unit [95% CI]: -0.32 [-0.48, -0.15] kg), after adjusting for age, sex, and parental BMI. In conclusion, the serum concentrations of PFCs were inversely associated with growth parameters in 2-year-old children. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong; Li, Ning
2016-12-01
Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC ( n = 65) and healthy control subjects ( n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC.
Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong
2016-01-01
Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC (n = 65) and healthy control subjects (n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC. PMID:27885040
Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L
2017-06-03
Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p < 0.004). In summary, when considering the acceptable change limit, BDNF was stable in serum and in EDTA-plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.
Grützner, Niels; Suchodolski, Jan S; Steiner, Jörg M
2014-12-01
Increased serum concentrations of homocysteine (HCY) and methylmalonic acid (MMA), the 2 main cobalamin-dependent metabolites, as well as decreased serum albumin and canine alpha1 -proteinase inhibitor (cα1 -PI) concentrations have previously been described in hypocobalaminemic dogs with gastrointestinal disease. However, no studies have been conducted to evaluate potential relationships between these serum biomarkers. The aim of this study was to evaluate the relationship between HCY and MMA, 2 cobalamin-dependent metabolites, and both serum albumin and cα1 -PI concentrations in hypocobalaminemic dogs. Serum samples from 285 dogs including 7 different breeds (Beagle, Boxer, Cocker Spaniel, German Shepherd, Labrador Retriever, Chinese Shar-Pei, and Yorkshire Terrier) with hypocobalaminemia were used. Serum HCY, MMA, albumin, and cα1 -PI concentrations were determined. There was a significant correlation between serum HCY and albumin concentrations, as well as serum HCY and cα1 -PI concentrations (ρ = 0.62 and ρ = 0.37, respectively; P < .0001). No correlations were observed between serum MMA and albumin concentrations, or cα1 -PI concentrations (ρ = 0.01 and ρ = 0.08, respectively; P > .05). In addition, significant breed-specific correlations were observed between serum MMA and albumin concentrations in German Shepherds, and serum HCY and MMA concentrations in Chinese Shar-Peis with hypocobalaminemia. This study shows a correlation between serum albumin and cα1 -PI and HCY concentrations, but not with serum MMA concentration in dogs with hypocobalaminemia. In addition, significant breed-specific correlations were observed between serum MMA and albumin concentrations in German Shepherds, as well as serum HCY and MMA concentrations in Chinese Shar-Peis, emphasizing the unique metabolic interactions in those dog breeds affected by hypocobalaminemia. © 2014 American Society for Veterinary Clinical Pathology.
Bobbo, T; Fiore, E; Gianesella, M; Morgante, M; Gallo, L; Ruegg, P L; Bittante, G; Cecchinato, A
2017-12-01
Blood serum proteins are significant indicators of animal health. Nevertheless, several factors should be considered to appropriately interpret their concentrations in blood. Therefore, the objectives of this study were (1) to assess the effect of herd productivity, breed, age and stage of lactation on serum proteins and (2) to investigate association between serum proteins and somatic cell count (SCC) in dairy cattle. Milk and blood samples were collected from 1508 cows of six different breeds (Holstein Friesian, Brown Swiss, Jersey, Simmental, Rendena and Alpine Grey) that were housed in 41 multi-breed herds. Milk samples were analyzed for composition and SCC, while blood samples were analyzed for serum proteins (i.e. total protein, albumin, globulin and albumin-to-globulin ratio (A : G)). Herds were classified as low or high production, according to the cow's average daily milk energy yield adjusted for breed, days in milk (DIM) and parity. Data were analyzed using a linear mixed model that included the fixed effects of DIM, parity, SCS, breed, herd productivity and the random effect of the Herd-test date within productivity level. Cows in high producing herds (characterized also by greater use of concentrates in the diet) had greater serum albumin concentrations. Breed differences were reported for all traits, highlighting a possible genetic mechanism. The specialized breed Jersey and the two dual-purpose local breeds (Alpine Grey and Rendena) had the lowest globulin concentration and greatest A : G. Changes in serum proteins were observed through lactation. Total protein reached the highest concentration during the 4th month of lactation. Blood albumin increased with DIM following a quadratic pattern, while globulin decreased linearly. As a consequence, A : G increased linearly during lactation. Older cows had greater total protein and globulin concentrations, while albumin concentration seemed to be not particularly affected by age. A linear relationship between serum proteins and SCS was observed. High milk SCS was associated with greater total protein and globulin concentrations in blood. The rise in globulin concentration, together with a decrease in albumin concentrations, resulted in a decline in A : G as SCS of milk increased. In conclusion, such non-genetic factors must be considered to appropriately interpret serum proteins as potential animal welfare indicator and their evaluation represents an important first-step for future analysis based on the integration of metabolomics, genetic and genomic information for improving the robustness of dairy cows.
Neuropsychiatric lupus erythematosus, cerebral infarctions, and anticardiolipin antibodies.
Fields, R A; Sibbitt, W L; Toubbeh, H; Bankhurst, A D
1990-01-01
Anticardiolipin antibody (aCL) has been associated with thromboembolic phenomena, including stroke, in certain patients with systemic lupus erythematosus (SLE); however, the relation between this antibody and the central nervous system manifestations of SLE is unknown. Serum samples and cerebrospinal fluid from five patients with SLE and acute central nervous system manifestations were assayed for the presence of aCL. Anticardiolipin antibody was identified in sera from four of the five patients but in none of the cerebrospinal fluid samples. Nuclear magnetic resonance imaging showed 'infarct-like' lesions in these four patients. This preliminary study suggests that a correlation between serum aCL and cerebral infarcts in central nervous system lupus may potentially exist. From this limited study it seems unlikely that aCL has a direct pathogenic role in the diffuse encephalopathy of acute central nervous system lupus. Images PMID:2317112
Acikgoz, Seyyid Bilal; Genc, Ahmet Bilal; Sipahi, Savas; Yildirim, Mehmet; Cinemre, Behice; Tamer, Ali; Solak, Yalcin
2016-05-01
Several studies investigated the agreement between central laboratory biochemistry analyzers and blood gas analyzers for potassium measurements. However, data are scarce when the potassium level is moderate to severely high. We aimed to evaluate the agreement between central laboratory biochemistry analyzers and blood gas analyzer in terms of serum potassium level measurement because differences in potassium at this level translate into very different clinical actions. This was a retrospective medical record review study in which patients who presented to the emergency department and had serum potassium levels ≥6mmol/L were included. Patients who did not have simultaneous potassium measurement by blood gas analyzer were excluded. We included all patients meeting potassium criteria irrespective of their underlying disease or comorbidities. We evaluated agreement between the measurement methods with Pearson correlation, Bland-Altman plot, and Sign test. A total of 118 blood sample pairs were included. The mean serum potassium level measured by biochemistry analyzer was 6.78±0.79mmol/L, whereas it was 6.16±0.86mmol/L by blood gas analyzer (P<.001, Sign test). There was a strong correlation (P<.001, r=0.864) between the 2 methods, but agreement was relatively poor. Blood gas analyzer tended to measure potassium significantly lower than measured by biochemistry analyzer. The mean difference between the methods was 0.62±0.43mmol/L. In patients with moderate to severe hyperkalemia, blood gas analyzer and biochemistry analyzer gives significantly different serum potassium results which may be clinically important. Copyright © 2016 Elsevier Inc. All rights reserved.
Sureda-Vives, Macià; Morell-Garcia, Daniel; Rubio-Alaejos, Ana; Valiña, Laura; Robles, Juan; Bauça, Josep Miquel
2017-09-01
Osmolality reflects the concentration of all dissolved particles in a body fluid, and its measurement is routinely performed in clinical laboratories for the differential diagnosis of disorders related with the hydrolytic balance regulation, the renal function and in small-molecule poisonings. The aim of the study was to assess the stability of serum, plasma and urine osmolality through time and under different common storage conditions, including delayed centrifugation. Blood and urine samples were collected, and classified into different groups according to several preanalytical variables: serum or plasma lithium-heparin tubes; spun or unspun; stored at room temperature (RT), at 4°C or frozen at -21°C. Aliquots from each group were assayed over time, for up to 14days. Statistical differences were based on three different international performance criteria. Whole blood stability was higher in the presence of anticoagulant. Serum osmolality was stable for 2days at RT and 8days at 4°C, while plasma was less stable when refrigerated. Urine stability was 5days at RT, 4days at 4°C and >14days when frozen. Osmolality may be of great interest for the management of several conditions, such as in case of a delay in the clinical suspicion, or in case of problems in sample collection or processing. The ability to obtain reliable results for samples kept up to 14days also offers the possibility to retrospectively assess baseline values for patients which may require it. Copyright © 2017. Published by Elsevier Inc.
Serum and saliva cortisol relations in adolescents during pregnancy and the early postpartum period.
Dorn, L D; Susman, E J
1993-08-15
The purpose of this investigation was to examine: (1) relations between serum and saliva cortisol in adolescents in pregnancy and early postpartum and (2) short-term consistency of serum and saliva cortisol across three samples, 20 minutes apart, as well as the long-term consistency from pregnancy to early postpartum. Pregnant adolescents (n = 40), ages 14 to 19 years, were enrolled in this study. Subjects were seen at 20 weeks gestation or earlier (T1), 34-36 weeks gestation (T2), and 2-3 weeks postpartum (T3). Blood samples were drawn at T1 and T3, at 0, 20, and 40 minutes. Saliva samples were collected across the same 40-minute period at T1, T2, and T3. Spearman rho (rs) correlation coefficients between serum and saliva ranged from 0.72 to 0.77 (T1), and 0.42 to 0.60 (T3) (p < or = 0.05). Short-term consistency between serum cortisol samples was 0.86-0.97 at T1 and 0.60-0.82 at T3. Short-term consistency for saliva cortisol samples was 0.70-0.96 at T1, 0.91-0.95 at T2, and 0.64-0.89 at T3. Long-term consistency (T1 to T3) for serum and saliva cortisol was low. Individual differences as well as dramatic changes in the endocrine environment in pregnancy and the early postpartum period may explain the more moderate serum-saliva correlations in the postpartum period.
Gas chromatography-mass spectrometry of biofluids and extracts.
Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Yang, Yang; Kharbatia, Najeh M
2015-01-01
Gas chromatography-mass spectrometry (GC-MS) has been widely used in metabonomics analyses of biofluid samples. Biofluids provide a wealth of information about the metabolism of the whole body and from multiple regions of the body that can be used to study general health status and organ function. Blood serum and blood plasma, for example, can provide a comprehensive picture of the whole body, while urine can be used to monitor the function of the kidneys, and cerebrospinal fluid (CSF) will provide information about the status of the brain and central nervous system (CNS). Different methods have been developed for the extraction of metabolites from biofluids, these ranging from solvent extracts, acids, heat denaturation, and filtration. These methods vary widely in terms of efficiency of protein removal and in the number of metabolites extracted. Consequently, for all biofluid-based metabonomics studies, it is vital to optimize and standardize all steps of sample preparation, including initial extraction of metabolites. In this chapter, recommendations are made of the optimum experimental conditions for biofluid samples for GC-MS, with a particular focus on blood serum and plasma samples.
Gefen, Aharon; Zaidman, Irina; Shachor-Meyouhas, Yael; Avidor, Israela; Hakim, Fahed; Weyl Ben-Arush, Myriam; Kassis, Imad
2015-03-01
Both transplanted and leukemia patients are at high risk (HR) for invasive pulmonary aspergillosis (IPA). Methods for rapid diagnosis are crucial. Our objective was to investigate the impact of serial serum galactomannan assay (GMA) screening on IPA diagnosis in children. Between January 2010 and December 2011, all children following stem cell transplantation (SCT) or with HR leukemia were prospectively included. Serum samples for GMA were taken once-twice weekly. Results >.5 were considered positive. Patients suspected of having IPA were stratified as possible, probable, and definite. Forty-six children (median age, 8 years) were included, 38 after SCT (32 allogeneic), 8 with HR leukemia. A total of 510 samples were taken; screening period was 1-6 months for 34 patients. GMA was negative in 28 patients, all but one without suspicion of IPA. Eighteen patients had positive GMA: while four (22%) were upgraded to probable IPA, fourteen (78%) were considered as false positives (FP), some associated with piperacillin-tazobactam treatment. GMA sensitivity and specificity were 0.8 and 0.66, respectively; positive- and negative-predictive values (PPV, NPV) were 0.22 and 0.96, respectively. GMA may have a role in evaluating HR children for IPA. Both NPV and FP rates are high. The cost benefit of early detection versus over-diagnosis should be further studied.
Moe, Sharon M; Chertow, Glenn M; Parfrey, Patrick S; Kubo, Yumi; Block, Geoffrey A; Correa-Rotter, Ricardo; Drüeke, Tilman B; Herzog, Charles A; London, Gerard M; Mahaffey, Kenneth W; Wheeler, David C; Stolina, Maria; Dehmel, Bastian; Goodman, William G; Floege, Jürgen
2015-07-07
Patients with kidney disease have disordered bone and mineral metabolism, including elevated serum concentrations of fibroblast growth factor-23 (FGF23). These elevated concentrations are associated with cardiovascular and all-cause mortality. The objective was to determine the effects of the calcimimetic cinacalcet (versus placebo) on reducing serum FGF23 and whether changes in FGF23 are associated with death and cardiovascular events. This was a secondary analysis of a randomized clinical trial comparing cinacalcet to placebo in addition to conventional therapy (phosphate binders/vitamin D) in patients receiving hemodialysis with secondary hyperparathyroidism (intact parathyroid hormone ≥300 pg/mL). The primary study end point was time to death or a first nonfatal cardiovascular event (myocardial infarction, hospitalization for angina, heart failure, or a peripheral vascular event). This analysis included 2985 patients (77% of randomized) with serum samples at baseline and 2602 patients (67%) with samples at both baseline and week 20. The results demonstrated that a significantly larger proportion of patients randomized to cinacalcet had ≥30% (68% versus 28%) reductions in FGF23. Among patients randomized to cinacalcet, a ≥30% reduction in FGF23 between baseline and week 20 was associated with a nominally significant reduction in the primary composite end point (relative hazard, 0.82; 95% confidence interval, 0.69-0.98), cardiovascular mortality (relative hazard, 0.66; 95% confidence interval, 0.50-0.87), sudden cardiac death (relative hazard, 0.57; 95% confidence interval, 0.37-0.86), and heart failure (relative hazard, 0.69; 95% confidence interval, 0.48-0.99). Treatment with cinacalcet significantly lowers serum FGF23. Treatment-induced reductions in serum FGF23 are associated with lower rates of cardiovascular death and major cardiovascular events. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00345839. © 2015 American Heart Association, Inc.
Environmental Chemicals in Urine and Blood: Improving Methods for Creatinine and Lipid Adjustment
O’Brien, Katie M.; Upson, Kristen; Cook, Nancy R.; Weinberg, Clarice R.
2015-01-01
Background Investigators measuring exposure biomarkers in urine typically adjust for creatinine to account for dilution-dependent sample variation in urine concentrations. Similarly, it is standard to adjust for serum lipids when measuring lipophilic chemicals in serum. However, there is controversy regarding the best approach, and existing methods may not effectively correct for measurement error. Objectives We compared adjustment methods, including novel approaches, using simulated case–control data. Methods Using a directed acyclic graph framework, we defined six causal scenarios for epidemiologic studies of environmental chemicals measured in urine or serum. The scenarios include variables known to influence creatinine (e.g., age and hydration) or serum lipid levels (e.g., body mass index and recent fat intake). Over a range of true effect sizes, we analyzed each scenario using seven adjustment approaches and estimated the corresponding bias and confidence interval coverage across 1,000 simulated studies. Results For urinary biomarker measurements, our novel method, which incorporates both covariate-adjusted standardization and the inclusion of creatinine as a covariate in the regression model, had low bias and possessed 95% confidence interval coverage of nearly 95% for most simulated scenarios. For serum biomarker measurements, a similar approach involving standardization plus serum lipid level adjustment generally performed well. Conclusions To control measurement error bias caused by variations in serum lipids or by urinary diluteness, we recommend improved methods for standardizing exposure concentrations across individuals. Citation O’Brien KM, Upson K, Cook NR, Weinberg CR. 2016. Environmental chemicals in urine and blood: improving methods for creatinine and lipid adjustment. Environ Health Perspect 124:220–227; http://dx.doi.org/10.1289/ehp.1509693 PMID:26219104
Zang, Xiaodong; Huang, Hesuyuan; Zhuang, Zhulun; Chen, Runsen; Xie, Zongyun; Xu, Cheng; Mo, Xuming
2018-06-01
Copper is an essential element in human beings, alterations in serum copper levels could potentially have effect on human health. To date, no data are available regarding how serum copper affects cardiovascular disease (CVD) risk factors in children and adolescents. We examined the association between serum copper levels and CVD risk factors in children and adolescents. We analyzed data consisting of 1427 subjects from a nationally representative sample of the US population in the National Health and Nutrition Examination Survey (NHANES) from 2011 to 2014. The CVD risk factors included total cholesterol, HDL-cholesterol, LDL-cholesterol, triglycerides, fasting glucose, glycohemoglobin, fasting insulin, and blood pressure. Multivariate and generalized linear regressions were performed to investigate associations adjusted for age, gender, ethnicity, poverty:income ratio (PIR), BMI, energy intake, and physical activity. We found significant associations between serum copper and total cholesterol (coefficient = 0.132; 95% CI 0.081, 0.182; P for trend < 0.001), glycohemoglobin (coefficient = 0.044; 95% CI 0.020, 0.069; P < 0.001), and fasting insulin (coefficient = 0.730; 95% CI 0.410, 1.050; P < 0.001) among the included participants. Moreover, in the generalized linear models, subjects with the highest copper levels demonstrated a 0.83% (95% CI 0.44%, 1.24%) greater increase in serum total cholesterol (p for trend < 0.001) when compared to participants with the lowest copper concentrations. Our results provide the first epidemiological evidence that serum copper concentrations are associated with total cholesterol concentrations in children and adolescents. However, the underlying mechanisms still need further exploration.
Stanek, J F; Stich, R W; Dubey, J P; Reed, S M; Njoku, C J; Lindsay, D S; Schmall, L M; Johnson, G K; LaFave, B M; Saville, W J A
2003-11-28
Equine protozoal myeloencephalitis (EPM) is a serious neurologic disease in the horse most commonly caused by Sarcocystis neurona. The domestic cat (Felis domesticus) is an intermediate host for S. neurona. In the present study, nine farms, known to have prior clinically diagnosed cases of EPM and a resident cat population were identified and sampled accordingly. In addition to the farm cats sampled, samples were also collected from a mobile spay and neuter clinic. Overall, serum samples were collected in 2001 from 310 cats, with samples including barn, feral and inside/outside cats. Of these 310 samples, 35 were from nine horse farms. Horse serum samples were also collected and traps were set for opossums at each of the farms. The S. neurona direct agglutination test (SAT) was used for both the horse and cat serum samples (1:25 dilution). Fourteen of 35 (40%) cats sampled from horse farms had circulating S. neurona agglutinating antibodies. Twenty-seven of the 275 (10%) cats from the spay/neuter clinic also had detectable S. neurona antibodies. Overall, 115 of 123 (93%) horses tested positive for anti-S. neurona antibodies, with each farm having greater than a 75% exposure rate among sampled horses. Twenty-one opossums were trapped on seven of the nine farms. Eleven opossums had Sarcocystis sp. sporocysts, six of them were identified as S. neurona sporocysts based on bioassays in gamma-interferon gene knockout mice with each opossum representing a different farm. Demonstration of S. neurona agglutinating antibodies in domestic and feral cats corroborates previous research demonstrating feral cats to be naturally infected, and also suggests that cats can be frequently infected with S. neurona and serve as one of several natural intermediate hosts for S. neurona.
Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav
2009-05-01
Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.
Stark, Klaus; Reinhard, Wibke; Grassl, Martina; Erdmann, Jeanette; Schunkert, Heribert; Illig, Thomas; Hengstenberg, Christian
2009-11-05
Recently, a large meta-analysis including over 28,000 participants identified nine different loci with association to serum uric acid (UA) levels. Since elevated serum UA levels potentially cause gout and are a possible risk factor for coronary artery disease (CAD) and myocardial infarction (MI), we performed two large case-control association analyses with participants from the German MI Family Study. In the first study, we assessed the association of the qualitative trait gout and ten single nucleotide polymorphisms (SNP) markers that showed association to UA serum levels. In the second study, the same genetic polymorphisms were analyzed for association with CAD. A total of 683 patients suffering from gout and 1,563 healthy controls from the German MI Family Study were genotyped. Nine SNPs were identified from a recently performed genome-wide meta-analysis on serum UA levels (rs12129861, rs780094, rs734553, rs2231142, rs742132, rs1183201, rs12356193, rs17300741 and rs505802). Additionally, the marker rs6855911 was included which has been associated with gout in our cohort in a previous study. SNPs rs734553 and rs6855911, located in SLC2A9, and SNP rs2231142, known to be a missense polymorphism in ABCG2, were associated with gout (p=5.6*10(-7), p=1.1*10(-7), and p=1.3*10(-3), respectively). Other SNPs in the genes PDZK1, GCKR, LRRC16A, SLC17A1-SLC17A3, SLC16A9, SLC22A11 and SLC22A12 failed the significance level. None of the ten markers were associated with risk to CAD in our study sample of 1,473 CAD cases and 1,241 CAD-free controls. SNP markers in SLC2A9 and ABCG2 genes were found to be strongly associated with the phenotype gout. However, not all SNP markers influencing serum UA levels were also directly associated with the clinical manifestation of gout in our study sample. In addition, none of these SNPs showed association with the risk to CAD in the German MI Family Study.
Christiansen, Anders; Kringelum, Jens V; Hansen, Christian S; Bøgh, Katrine L; Sullivan, Eric; Patel, Jigar; Rigby, Neil M; Eiwegger, Thomas; Szépfalusi, Zsolt; de Masi, Federico; Nielsen, Morten; Lund, Ole; Dufva, Martin
2015-08-06
Phage display is a prominent screening technique with a multitude of applications including therapeutic antibody development and mapping of antigen epitopes. In this study, phages were selected based on their interaction with patient serum and exhaustively characterised by high-throughput sequencing. A bioinformatics approach was developed in order to identify peptide motifs of interest based on clustering and contrasting to control samples. Comparison of patient and control samples confirmed a major issue in phage display, namely the selection of unspecific peptides. The potential of the bioinformatic approach was demonstrated by identifying epitopes of a prominent peanut allergen, Ara h 1, in sera from patients with severe peanut allergy. The identified epitopes were confirmed by high-density peptide micro-arrays. The present study demonstrates that high-throughput sequencing can empower phage display by (i) enabling the analysis of complex biological samples, (ii) circumventing the traditional laborious picking and functional testing of individual phage clones and (iii) reducing the number of selection rounds.
In vitro production of GHB in blood and serum samples under various storage conditions.
Zörntlein, S W; Kopp, A; Becker, J; Kaufmann, T J; Röhrich, J; Urban, R
2012-01-10
The in vitro production of GHB was observed in freshly collected, untreated whole blood samples using glass BD-Vacutainers and polypropylene S-monovettes. GHB concentrations were determined daily over a period of one week and after 3, 6 and 9 weeks again. Furthermore, the GHB concentration in 40 untreated random whole blood samples stored at 4°C for a longer period of time (10 samples 12 month, 10 samples 24 month and 20 samples 36 month) was also determined. For comparison, the in vitro production of GHB in freshly collected and prepared serum samples was observed. GHB serum concentrations were determined three times over a period of one week and once again after six weeks. Sample preparation was performed by means of methanolic extraction following the precipitation of whole blood and serum samples. A methanolic standard calibration was done in a low range of 0.005-0.1 μg/mL (LOD: 0.004, LLOQ: 0.013). For quantification a spiked blood bank serum with a determined GHB concentration of 0.09 μg/mL was used. Corrected calibrations in the range of 0.09-5.09 μg/mL were used (LOD: 0.08 μg/mL, LLOQ: 0.30 μg/mL), recovery: 91.3% (high level: 4.09 μg/mL) 50.5% (low level: 0.19 μg/mL). Relevant elevation of GHB was observed in all whole blood samples stored in liquid form (4°C or room temperature). In two of the 40 whole blood samples stored over a longer period of time at 4°C, GHB concentrations in the range of 13 μg/mL were even determined. These findings constitute grounds for caution. Even a GHB cut-off level of 5 μg/mL cannot be considered as "absolutely positive" proof of a case of exogenous administration, at least in untreated liquid blood samples in long time storage. However, no significant elevations of GHB were otherwise observed in any of the serum samples independently of storage temperature nor in the whole blood samples that were frozen for storage. The results suggest that the cut-off for exogenous GHB of 5 μg/mL could be lowered significantly, with the consequence of winning valuable time for the potential victim, but only if serum is collected for GHB determination or if the whole blood sample is frozen immediately after collection and the procedure well documented. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Hirokawa, Kumi; Taniguchi, Toshiyo; Fujii, Yasuhito
2015-02-01
Although serum cortisol is a widely accepted index of stress levels, associations between job stress and cortisol levels have been inconsistent. Individual differences in personality traits were discussed as one compelling explanation for this discrepancy. Agentic-communal personality traits have been examined as possible predictive factors for psychological stress. This study investigated correlations among agentic-communal personality traits and serum cortisol levels. It was also investigated whether job stress levels modified correlations between agentic-communal personality and cortisol levels. Participants were 198 male workers (mean age = 52.2 years) employed by a shipbuilding company in Japan. Questionnaire data and blood samples were collected during an annual health checkup. Participants completed a self-report questionnaire that included the Job Content Questionnaire (JCQ) that assesses job control as job stress levels the Communion-Agency scale (CAS) and questions regarding health behaviors. Communion positively correlated with serum cortisol levels and unmitigated agency negatively correlated with serum cortisol levels. Stratified by job control, communion positively correlated with serum cortisol levels and agency negatively correlated with serum cortisol levels in participants with low levels of job control. Unmitigated agency negatively correlated with serum cortisol levels in participants with high levels of job control. Levels of job control may modify correlations of gender-related personality with serum cortisol levels. Especially with exposure to high job stress, male workers with high femininity (i.e., high communion and low agency) were more likely to have a high stress response as measured by serum cortisol levels.
Determination of chlormequat in pig serum and sow milk by LC-MS/MS.
Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H
2007-11-01
Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.
Hoque, M M; Adnan, S D; Karim, S; Al-Mamun, M A; Faruki, M A; Islam, K; Nandy, S
2016-04-01
Blood donation results in a substantial iron loss and subsequent mobilization from body stores. Chronic iron deficiency is a well-recognized complication of regular blood donation. The present study conducted to compare the level of serum ferritin, serum iron, total iron binding capacity (TIBC) and percentage transferrin saturation in different ABO and Rhesus type blood groups among the voluntary blood donors of Bangladesh. The present prospective study included 100 healthy voluntary donors attending at Department of Blood Transfusion, Dhaka Medical College, Dhaka between the periods of July 2013 to Jun 2014. From each donor 10mL venous blood sample was taken and divided into heparinized and non-heparinized tubes for determination of hemoglobin (Hb), hematocrit (Hct), serum iron (SI), total iron binding capacity (TIBC) and serum ferritin by standard laboratory methods. Percentage of transferrin saturation (TS) calculated from serum iron and TIBC. Data were analyzed with SPSS (version 16) software and comparisons between groups were made using student's t-test and one way ANOVA. In the present study mean±SD of age of the respondents was 27.2±6.5 years with a range of 18 to 49 years and 81.0% were male and 19.0% were female. Among the donors 18.0% had blood group A, 35.0% had blood group B, 14.0% had blood group AB and 33.0% had blood group O. Among the donors 91.0% had rhesus positive and 9.0% had rhesus negative. Donors with blood group O had lowest haemoglobin, serum iron and transferring saturation levels. Donors with blood group A had highest TIBC level. Donors with blood group B had lowest serum ferritin level. An independent samples 't' test showed statistically significant difference in serum ferritin and percentage transferrin saturation between blood group AB and blood group O and in percentage transferrin saturation between blood group B and blood group O. One way ANOVA showed that there is no significant difference in haemoglobin, serum iron, serum ferritin and percentage transferring saturation in different ABO and Rh blood grouping categories. Blood donors with blood group O had lowest haemoglobin, serum iron and transferring saturation levels and donors with blood group A had highest TIBC level. Blood donors with blood group B had lowest serum ferritin level. The understanding of the different blood groups ability to retain iron in their system can give an insight into their ability to handle the disease iron deficiency anaemia.
Gil, A.; González, A.; Dal-Ré, R.; Dominguez, V.; Astasio, P.; Aguilar, L.
1997-01-01
Diluted dried blood drops on filter paper were compared with serum samples as a specimen source for qualitative anti-HAV antibody determination by ELISA. A total of 298 serum samples and dried blood drops were collected from a population of healthy adolescents (15.3 +/- 1.2 years old). The prevalence of anti-HAV antibody obtained by testing serum samples was 7.7% (95% CI:4.8 10.1). Compared with serum sampling the sensitivity and specificity of diluted dried blood drops were 91.3 and 99.3%. The positive and negative predictive values were 91.3 and 99.3%, respectively, and the likelihood ratios of positive and negative results were 91 and 0.09. It is proposed that this test represents a reliable procedure for anti-HAV antibody testing. PMID:9129596
Torres, J R; Mondolfi, A
1991-01-01
In an investigation of a 21-year-old epidemic of severe hepatitis, 80 serum samples were studied from two isolated Yanomami Amerindian populations of the Upper Orinoco basin in Venezuela. Of the assayed samples, 30.6% were positive for hepatitis B surface antigen (HBsAg), 53.7% were considered to reflect immunity to infection with hepatitis B virus (HBV), and only 16.2% were believed to reflect susceptibility to HBV infection; 82.5% of the samples tested positive for any marker of HBV infection. Thirty-one (39.7%) of 78 samples were also positive for antibody to delta antigen, including 91.6% of those positive for HBsAg and 20.9% of those immune to HBV. Our findings provide evidence of a high prevalence of HBV infection in this population. Furthermore, the high prevalence of antibody to delta antigen strongly suggests that coinfections with HBV or superinfections with hepatitis delta virus (HDV) in HBV carriers may be an important factor in the occurrence of an unusually high number of cases of fulminant hepatitis and of chronic liver disease. Serum samples obtained at the beginning of the outbreak 13 years earlier from 36 selected cases in the same population revealed a high rate of HBV infection (96.5%). All six HBsAg carriers from whom enough serum remained to be assayed were positive for antibody to delta antigen. Our findings indicate that the outbreak coincided with the introduction of HDV into a population with an already-high prevalence of HBV infection.
A bacterial engineered glycoprotein as a novel antigen for diagnosis of bovine brucellosis.
Ciocchini, Andrés E; Serantes, Diego A Rey; Melli, Luciano J; Guidolin, Leticia S; Iwashkiw, Jeremy A; Elena, Sebastián; Franco, Cristina; Nicola, Ana M; Feldman, Mario F; Comerci, Diego J; Ugalde, Juan E
2014-08-27
Brucellosis is a highly contagious zoonosis that affects livestock and human beings. Laboratory diagnosis of bovine brucellosis mainly relies on serological diagnosis using serum and/or milk samples. Although there are several serological tests with different diagnostic performance and capacity to differentiate vaccinated from infected animals, there is still no standardized reference antigen for the disease. Here we validate the first recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of bovine brucellosis. This antigen can be produced in homogeneous batches without the need of culturing pathogenic brucellae; all characteristics that make it appropriate for standardization. An indirect immunoassay based on the detection of anti O-polysaccharide IgG antibodies in bovine samples was developed coupling OAg-AcrA to magnetic beads or ELISA plates. As a proof of concept and to validate the antigen, we analyzed serum, whole blood and milk samples obtained from non-infected, experimentally infected and vaccinated animals included in a vaccination/infection trial performed in our laboratory as well as more than 1000 serum and milk samples obtained from naturally infected and S19-vaccinated animals from Argentina. Our results demonstrate that OAg-AcrA-based assays are highly accurate for diagnosis of bovine brucellosis, even in vaccinated herds, using different types of samples and in different platforms. We propose this novel recombinant glycoprotein as an antigen suitable for the development of new standard immunological tests for screening and confirmatory diagnosis of bovine brucellosis in regions or countries with brucellosis-control programs. Copyright © 2014 Elsevier B.V. All rights reserved.
Fujii, Yuji; Henares, Terence G; Kawamura, Kunio; Endo, Tatsuro; Hisamoto, Hideaki
2012-04-21
To enhance sensitivity and facilitate easy sample introduction into a combinable poly(dimethylsiloxane) (PDMS) capillary (CPC) sensor array, PDMS was modified in bulk and on its surface to prepare "black" PDMS coated with a silver layer and self-assembled monolayer (SAM). India ink, a traditional Japanese black ink, was added to the PDMS pre-polymer for bulk modification. The surface was modified by a silver mirror reaction followed by SAM formation using cysteine. These modifications enhanced the fluorescence signals by reflecting them from the surface and reducing background interference. A decrease in the water contact angle led to enhanced sensitivity and easy sample introduction. Furthermore, a CPC sensor array for multiplex detection of serum sample components was prepared that could quantify the analytes glucose, potassium, and alkaline phosphatase (ALP). When serum samples were introduced by capillary action, the CPC sensor array showed fluorescence responses for each analyte and successfully identified the components with elevated concentrations in the serum samples.
Gastrointestinal parasites of feral cats from Christmas Island.
Adams, P J; Elliot, A D; Algar, D; Brazell, R I
2008-01-01
To investigate the gastrointestinal parasites present in feral cats on Christmas Island, with particular interest in the protozoan parasite Toxoplasma gondii. Faecal and serum samples were collected from 28 and 25 cats respectively that were trapped as part of an ongoing eradication program being run on Christmas Island by the Department of Environment and Conservation. Faecal samples were screened microscopically for helminth and protozoan parasites. Serum samples were screened for antibodies to T gondii using a commercial indirect immunofluorescence assay (IFA) and a latex agglutination test (LAT). The most common helminth parasites detected were Toxocara cati (present in 15 of 28 faecal samples), Strongyloides sp (13/28), Aelurostrongylus abstrusus, (7/28), an unidentified capillarid (6/28) and Ancylostoma sp (4/28). Based on serology, T gondii was the most common parasite detected (protozoan or otherwise) with antibodies detected in 24 serum samples by IFA and 23 serum samples by LAT. Cats on Christmas Island harbour many of the helminth and protozoan parasites reported from feral cats elsewhere in Australia. The high seroprevalence of T gondii in these cats indicates a high level of exposure to the parasite in this environment.
Sonu, Yeldose; Avinash, S S; Sreekantha; Arun Kumar, K; Malathi, M; Shivashankara, A R
2016-07-01
Given the paucity of studies conducted to know the effect of suddenness and earlier onset of endocrinological changes associated with hysterectomy, on the serum and urinary levels of calcium, magnesium and phosphate the present study was conducted to compare the levels of calcium, magnesium and phosphate in serum and urine of hysterectomised and natural menopausal south Indian women. This is a cross-sectional observational study. The study included three groups of 30 healthy premenopausal, 30 early surgical menopausal and 30 natural post menopausal women. Women suffering from any endocrine disease were excluded. Analysis was performed in serum and urine sample. The levels of calcium, magnesium and phosphate in serum and calcium/creatinine, magnesium/creatinine and phosphate/creatinine ratio were estimated in urine by spectrophotometric method. Hysterectomised women (serum calcium: 8.7 ± 0.09 mg/dl; urine calcium/creatinine: 0.16 ± 0.02) have significantly low serum calcium (p < 0.001) and high urinary calcium/creatinine (p = 0.002) ratio and post menopausal women (serum magnesium: 2.1 ± 0.03; serum phosphate: 4.4 ± 0.16; urinary calcium/creatinine: 0.17 ± 0.02; urinary magnesium/creatinine: 0.09 ± 0.01) have significantly high serum magnesium (p = 0.016), serum phosphate (p = 0.043) and high urinary calcium/creatinine (p = 0.002), magnesium/creatinine ratio (p = 0.025) compared to healthy pre menopausal women. Post menopausal women (serum calcium: 9.1 ± 0.08) have significantly high serum calcium and phosphate compared to hysterectomised women (serum phosphate: 3.93 ± 0.11). Hysterectomised women have significantly low serum calcium, oestrogen and high urinary calcium/creatinine ratio compared to healthy premenopausal women and low serum calcium and low serum phosphate compared to natural postmenopausal women. Natural postmenopausal women had low serum oestrogen and high serum magnesium, serum phosphate, urinary calcium creatinine ratio and urinary magnesium creatinine ratio compared to healthy premenopausal women.
Screening and staging for non-small cell lung cancer by serum laser Raman spectroscopy.
Wang, Hong; Zhang, Shaohong; Wan, Limei; Sun, Hong; Tan, Jie; Su, Qiucheng
2018-08-05
Lung cancer is the leading cause of cancer-related death worldwide. Current clinical screening methods to detect lung cancer are expensive and associated with many complications. Raman spectroscopy is a spectroscopic technique that offers a convenient method to gain molecular information about biological samples. In this study, we measured the serum Raman spectral intensity of healthy volunteers and patients with different stages of non-small cell lung cancer. The purpose of this study was to evaluate the application of serum laser Raman spectroscopy as a low cost alternative method in the screening and staging of non-small cell lung cancer (NSCLC). The Raman spectra of the sera of peripheral venous blood were measured with a LabRAM HR 800 confocal Micro Raman spectrometer for individuals from five groups including 14 healthy volunteers (control group), 23 patients with stage I NSCLC (stage I group), 24 patients with stage II NSCLC (stage II group), 19 patients with stage III NSCLC (stage III group), 11 patients with stage IV NSCLC (stage IV group). Each serum sample was measured 3 times at different spots and the average spectra represented the signal of Raman spectra in each case. The Raman spectrum signal data of the five groups were statistically analyzed by analysis of variance (ANOVA), principal component analysis (PCA), linear discriminant analysis (LDA), and cross-validation. Raman spectral intensity was sequentially reduced in serum samples from control group, stage I group, stage II group and stage III/IV group. The strongest peak intensity was observed in the control group, and the weakest one was found in the stage III/IV group at bands of 848 cm -1 , 999 cm -1 , 1152 cm -1 , 1446 cm -1 and 1658 cm -1 (P < 0.05). Linear discriminant analysis showed that the sensitivity to identify healthy people, stage I, stage II, and stage III/IV NSCLC was 86%, 65%, 75%, and 87%, respectively; the specificity was 95%, 94%, 88%, and 93%, respectively; and the overall accuracy rate was 92% (71/77). The laser Raman spectroscopy can effectively identify patients with stage I, stage II or stage III/IV Non-Small Cell Lung cancer using patient serum samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Díaz de Bustamante, M; Alarcón, T; Menéndez-Colino, R; Ramírez-Martín, R; Otero, Á; González-Montalvo, J I
2018-01-01
Backgrounds/objectives:Malnutrition is very common in acute hip fracture (HF) patients. Studies differ widely in their findings, with reported prevalences between 31 and 88% mainly because of small sample sizes and the use of different criteria. The aim of this study was to learn the prevalence of malnutrition in a large cohort of HF patients in an comprehensive way that includes the frequency of protein-energy malnutrition, vitamin D deficiency and sarcopenia. A 1-year consecutive sample of patients admitted with fragility HF in a 1300-bed public University Hospital, who were assessed within the first 72 h of admission. Clinical, functional, cognitive and laboratory variables were included. Energy malnutrition (body mass index (BMI) <22 kg/m 2 ), protein malnutrition (serum total protein <6.5 g/dl or albumin <3.5 g/dl), vitamin D deficiency (serum 25-OH-vitamin D <30 ng/dl) and sarcopenia (low muscle mass plus low grip strength) were considered. Five hundred nine HF patients were included. The mean age was 85.6±6.9 years and 79.2% were women. Ninety-nine (20.1%) patients had a BMI <22 kg/m 2 . Four hundred nine patients (81.2%) had protein malnutrition. Eighty-seven (17.1%) patients had both energy and protein malnutrition. Serum vitamin D was <30 ng/ml in 466 (93%) patients. The prevalence of sarcopenia was 17.1%. Protein malnutrition and vitamin D deficiency are the rule in acute HF patients. Energy malnutrition and sarcopenia are also common. A nutritional assessment in these patients should include these aspects together.
Müller, A; Freude, B
2016-01-01
An optimal selenium supply of cattle is essential, because an insufficiency can lead to health disorders and reduced performance. The aim of the study was to retrospectively evaluate the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Serum samples from 45 068 cattle with unknown clinical status originating from countries all across Europe, which had been sent by veterinarians to the IDEXX Laboratory Ludwigsburg, Germany, between January 1st, 2006 and June 30th, 2015, were routinely analyzed for the selenium concentration by means of Inductively Coupled Plasma Mass Spectrometry. A total of 40 949 samples (30 462 from Germany, 4004 from Austria, 3232 from Switzerland, 3251 from Denmark) were included in the evaluation. Results were categorized as follows: 50-150 µg/l: sufficient supply, < 50 µg/l: supply too low, > 150 µg/l: supply too high. During the observation period, a generalized trend towards a decreasing selenium supply was clear. Denmark showed the best selenium supply (77.4% of samples indicating a sufficient supply); however, even in this country a tendency towards a deterioration was seen. A very poor situation with a strongly decreasing selenium supply was observed in Austria, followed by Germany (38% and 30% of samples, respectively, indicating an undersupply). For Switzerland, a constantly poor selenium supply was found (49% of samples indicating an undersupply). Due to the ongoing trend of a selenium undersupply in cattle herds, it is recommended to control the serum selenium concentration annually and supplement this trace element via mineral food when necessary.
Stein, Cheryl R.; Wolff, Mary S.; Calafat, Antonia M.; Kato, Kayoko; Engel, Stephanie M.
2012-01-01
The extent to which polyfluoroalkyl compounds (PFCs) are detectable in amniotic fluid is unknown. Using paired samples from 28 women, we compared the concentration of 8 PFCs measured in serum, the standard matrix for assessing human exposure, amniotic fluid from routine amniocentesis, and urine. Perfluorooctanoate (PFOA), perfluorononanoate (PFNA), perfluorooctane sulfonate (PFOS), and perfluorohexane sulfonate (PFHxS) were detected in all maternal serum samples. The number of amniotic fluid samples with detectable concentrations differed by PFC (PFOA n=24; PFNA n=10; PFOS n=9; PFHxS n=4). The correlation coefficient between maternal serum and amniotic PFC levels varied considerably by PFC (PFOA ρ=0.64, p<0.001; PFNA ρ=0.05, p=0.9; PFOS ρ=0.76, p=0.01; PFHxS ρ=0.80, p=0.2). Using linear regression, PFOA appeared to be commonly detected in amniotic fluid if the serum concentration exceeded approximately 1.5 ng/mL whereas PFOS was rarely detected in amniotic fluid until the serum concentration was about 5.5 ng/mL. No PFCs were detected in urine. PMID:22613200
A novel diagnostic biomarker panel for obesity-related nonalcoholic steatohepatitis (NASH).
Younossi, Zobair M; Jarrar, Mohammed; Nugent, Clare; Randhawa, Manpreet; Afendy, Mariam; Stepanova, Maria; Rafiq, Nila; Goodman, Zachary; Chandhoke, Vikas; Baranova, Ancha
2008-11-01
Within the spectrum of nonalcoholic fatty liver disease (NAFLD), only patients with nonalcoholic steatohepatitis (NASH) show convincing evidence for progression. To date, liver biopsy remains the gold standard for the diagnosis of NASH; however, liver biopsy is expensive and associated with a small risk, emphasizing the urgent need for noninvasive diagnostic biomarkers. Recent findings suggest a role for apoptosis and adipocytokines in the pathogenesis of NASH. The aim of this study was to develop a noninvasive diagnostic biomarker for NASH. The study included 101 patients with liver biopsies who were tested with enzyme-linked immunosorbent assay (ELISA)-based assays. Of these, 69 were included in the biomarker development set and 32 were included in the biomarker validation set. Clinical data and serum samples were collected at the time of biopsy. Fasting serum samples were assayed for adiponectin, resistin, insulin, glucose, TNF-alpha, IL-6, IL-8, cytokeratin CK-18 (M65 antigen), and caspase-cleaved CK-18 (M30 antigen). Data analysis revealed that the levels of M30 antigen (cleaved CK-18) predicted histological NASH with 70% sensitivity and 83.7% specificity and area under the curve (AUC) = 0.711, p < 10(-4), whereas the predictive value of the levels of intact CK-18 (M65) was higher (63.6% sensitivity and 89.4% specificity and AUC = 0.814, p < 10(-4)). Histological NASH could be predicted by a combination of Cleaved CK-18, a product of the subtraction of Cleaved CK-18 level from intact CK-18 level, serum adiponectin, and serum resistin with a sensitivity of 95.45% sensitivity, specificity of 70.21%, and AUC of 0.908 (p < 10(-4)). Blinded validation of this model confirmed its reliability for separating NASH from simple steatosis. Four ELISA-based tests were combined to form a simple diagnostic biomarker for NASH.
Estimating GFR Among Participants in the Chronic Renal Insufficiency Cohort (CRIC) Study
Anderson, Amanda Hyre; Yang, Wei; Hsu, Chi-yuan; Joffe, Marshall M.; Leonard, Mary B.; Xie, Dawei; Chen, Jing; Greene, Tom; Jaar, Bernard G.; Kao, Patricia; Kusek, John W.; Landis, J. Richard; Lash, James P.; Townsend, Raymond R.; Weir, Matthew R.; Feldman, Harold I.
2012-01-01
Background Glomerular filtration rate (GFR) is considered the best measure of kidney function, but repeated assessment is not feasible in most research studies. Study Design Cross-sectional study of 1,433 participants from the Chronic Renal Insufficiency Cohort (CRIC) Study (i.e., the GFR subcohort) to derive an internal GFR estimating equation using a split sample approach. Setting & Participants Adults from 7 US metropolitan areas with mild to moderate chronic kidney disease; 48% had diabetes and 37% were black. Index Test CRIC GFR estimating equation Reference Test or Outcome Urinary 125I-iothalamate clearance testing (measured GFR) Other Measurements Laboratory measures including serum creatinine and cystatin C, and anthropometrics Results In the validation dataset, the model that included serum creatinine, serum cystatin C, age, gender, and race was the most parsimonious and similarly predictive of mGFR compared to a model additionally including bioelectrical impedance analysis phase angle, CRIC clinical center, and 24-hour urinary creatinine excretion. Specifically, the root mean square errors for the separate model were 0.207 vs. 0.202, respectively. The performance of the CRIC GFR estimating equation was most accurate among the subgroups of younger participants, men, non-blacks, non-Hispanics, those without diabetes, those with body mass index <30 kg/m2, those with higher 24-hour urine creatinine excretion, those with lower levels of high-sensitivity C-reactive protein, and those with higher mGFR. Limitations Urinary clearance of 125I-iothalamate is an imperfect measure of true GFR; cystatin C is not standardized to certified reference material; lack of external validation; small sample sizes limit analyses of subgroup-specific predictors. Conclusions The CRIC GFR estimating equation predicts measured GFR accurately in the CRIC cohort using serum creatinine and cystatin C, age, gender, and race. Its performance was best among younger and healthier participants. PMID:22658574
Monteiro, F.C.; Mandarino, N.R.; Santos, E.M.; Santos, A.M.; Salgado, J.V.; Brito, D.J.A.; Salgado, B.J.L.; Lages, J.S.; Castelo Branco, G.; Salgado, N.
2018-01-01
Hypovitaminosis D has been identified as a possible new cardiovascular risk factor. However, the results of studies correlating serum vitamin D levels with markers of subclinical atherosclerosis have been conflicting. The aim of this study was to correlate serum levels of 25-hydroxyvitamin D [25(OH)D] with carotid intima-media thickness (C-IMT) and conventional cardiovascular risk factors in Afro-descendants. A cross-sectional analysis was performed on a sample of 382 individuals from a cohort of descendants of African slaves, inhabitants of “Quilombola” communities, with a mean age of 57.79 ±15.3 years, 54.5% of whom were women. Socio-demographic and clinical data were collected and biochemical tests were performed, including serum levels of 25(OH)D by electrochemiluminescence and urinary albumin excretion, evaluated by the albumin/creatinine ratio (ACR) in a spot urine sample. All participants underwent high-resolution ultrasonography for C-IMT measurement. Hypovitaminosis D was defined as serum 25(OH)D levels <30 ng/mL. The mean serum 25(OH)D levels were 50.4±13.5 ng/mL, with a low prevalence of hypovitaminosis D (4.86%). By simple linear correlation, a significant inverse association between 25(OH)D levels and C-IMT (r=-0.174, P=0.001) was observed. However, after multiple linear regression analysis, the significance of the association between serum levels of 25(OH)D and C-IMT measurement was lost (β=-0.039, P=0.318) and only male gender, age, smoking, systolic blood pressure, glucose and low density lipoprotein (LDL)-cholesterol remained significantly associated with C-IMT. Levels of 25(OH)D were independently and positively associated with HDL-cholesterol and inversely associated with age and ACR. In conclusion, no independent association between 25(OH)D levels and C-IMT was observed in this population. On the other hand, there was an inverse association with albuminuria, a marker of endothelial lesion. PMID:29490002
Monteiro Júnior, F C; Mandarino, N R; Santos, E M; Santos, A M; Salgado, J V; Brito, D J A; Salgado, B J L; Lages, J S; Castelo Branco, G; Salgado Filho, N
2018-01-01
Hypovitaminosis D has been identified as a possible new cardiovascular risk factor. However, the results of studies correlating serum vitamin D levels with markers of subclinical atherosclerosis have been conflicting. The aim of this study was to correlate serum levels of 25-hydroxyvitamin D [25(OH)D] with carotid intima-media thickness (C-IMT) and conventional cardiovascular risk factors in Afro-descendants. A cross-sectional analysis was performed on a sample of 382 individuals from a cohort of descendants of African slaves, inhabitants of "Quilombola" communities, with a mean age of 57.79 ±15.3 years, 54.5% of whom were women. Socio-demographic and clinical data were collected and biochemical tests were performed, including serum levels of 25(OH)D by electrochemiluminescence and urinary albumin excretion, evaluated by the albumin/creatinine ratio (ACR) in a spot urine sample. All participants underwent high-resolution ultrasonography for C-IMT measurement. Hypovitaminosis D was defined as serum 25(OH)D levels <30 ng/mL. The mean serum 25(OH)D levels were 50.4±13.5 ng/mL, with a low prevalence of hypovitaminosis D (4.86%). By simple linear correlation, a significant inverse association between 25(OH)D levels and C-IMT (r=-0.174, P=0.001) was observed. However, after multiple linear regression analysis, the significance of the association between serum levels of 25(OH)D and C-IMT measurement was lost (β=-0.039, P=0.318) and only male gender, age, smoking, systolic blood pressure, glucose and low density lipoprotein (LDL)-cholesterol remained significantly associated with C-IMT. Levels of 25(OH)D were independently and positively associated with HDL-cholesterol and inversely associated with age and ACR. In conclusion, no independent association between 25(OH)D levels and C-IMT was observed in this population. On the other hand, there was an inverse association with albuminuria, a marker of endothelial lesion.
[False positive serum des-gamma-carboxy prothrombin after resection of hepatocellular carcinoma].
Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi
2007-04-01
Measurements of serum concentrations of des-gamma-carboxy-prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, when we evaluated the correlation of PIVKA-II between two commercially available PIVKA-II immunoassay kits (Lumipulse f vs. Picolumi) to introduce it in our hospital, false high values of PIVKA-II were observed in Lumipulse assay. Four(4%) of 100 serum samples showed false high values, and all of them were obtained from patients less than 2 month after curative resection of HCC. Examining additional 7 patients with HCC resection, serum samples from the 5 patients had the same trend. To elucidate the non-specific reaction by Lumipulse assay which utilized alkaline phosphatase (ALP) enzymatic reaction, inhibition assays by various absorbents such as inactive ALP and IgM antibodies were performed. Excess of inactive ALP reduced the high values of PIVKA-II. Note that anti-bleeding sheets (fibrinogen combined drug), which included bovine thrombin, were directly attached on liver of all patients with HCC resection in this study. As the sheets also contaminate ALP and probably produce IgM antibodies to ALP, the IgM may cross-react with anti-PIVKA-II antibodies directly. Taken together, it was suggested that produced antibodies against ALP derived from anti-bleeding sheets led false high values of PIVKA-II in the patients with HCC resection.
2015-09-30
ranging individuals support the existence of these same stress response pathways in marine mammals. 2 While the HPA axis and physiological processes...relying upon methods which include capture-release health assessments. Stress and reproductive hormones (cortisol, aldosterone , thyroid, testosterone...Analyses Hormone concentrations (cortisol, aldosterone , reproductive and thyroid hormones) in serum samples were analyzed by Cornell’s Animal Health
Karlicic, Vukoica; Vukovic, Jelena; Stanojevic, Ivan; Sotirovic, Jelena; Peric, Aleksandar; Jovic, Milena; Cvijanovic, Vlado; Djukic, Mirjana; Banovic, Tatjana; Vojvodic, Danilo
2016-01-01
Advanced lung carcinoma is charasterized with fast disease progression. Interleukin (IL)10 and transforming growth factor (TGF)b1 are immunosuppressive mediators and their role in lung carcinoma pathogenesis and in the antitumor response has not yet been elucidated. The purpose of this study was to correlate IL10 and TGFb1 levels in the serum and lung tumor microcirculation with clinical stage, disease extent, histological features and TNM stage. The study included 41 lung cancer patients in clinical stage III and IV. Histological type was determined immunohistochemically, while tumor size, localization and dissemination were determined radiologically by multislice computerized tomography (MSCT). IL10 and TGFb1 levels were quantified with commercial flow cytometric test in serum and lung tumor microcirculation samples. Non small cell lung cancer (NSCLC) patients had significantly elevated TGFb1 while small cell lung cancer (SCLC) patients had significantly increased IL10 in tumor microcirculation. IL10 was significantly elevated in patients with the largest tumors, as well as in patients with III clinical stage and without metastases, both in the serum and tumor microcirculation. TGFb1 was significantly increased in serum and tumor microcirculation in patients with larger tumors. We found significant correlation between these two immunosuppressive cytokines, IL10 and TGFb1, in tumor microcirculation but not in patient serum samples. IL10 and TGFb1 in systemic and tumor microcirculation are significantly associated with particular histological type of lung cancer, tumor size and degree of disease extent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saunders, G.C.
1977-01-01
A rapid enzyme-labeled antibody (ELA) microtechnique for the screening of swine for hog cholera antibodies was developed and evaluated with a blind study, using a 640-sample hog cholera serum bank. The total time to run a group of 22 samples was approximately 1 hour. The ELA test results correlated >99% with hog cholera serum-neutralization test results on the same serums. Test results also indicated that the ELA test shares with the hog cholera serum-neutralization test the problem of cross reactions between the antibodies of hog cholera and bovine viral diarrhea.
NASA Astrophysics Data System (ADS)
Lee, Jack Monroe, Jr.
There is ongoing controversy about the possibility of adverse biological effects from environmental exposures to electric and magnetic fields. These fields are produced by all electrical equipment and appliances including electrical transmission lines. The objective of this environmental science study was to investigate the possible effects of a high voltage transmission line on domestic sheep (Ovis aries L.), a species that can often be found near such lines. The study was primarily designed to determine whether a specific effect of electric and magnetic fields found in laboratory animals also occurs in livestock under natural environmental conditions. The effect is the ability of fields, at levels found in the environment, to significantly depress the normally high nocturnal concentrations of the pineal hormone-melatonin. Ten female Suffolk lambs were penned for 10 months directly beneath a 500-kV transmission line near Estacada, Oregon. Ten other lambs of the same type were penned in a control area away from the transmission line where electric and magnetic fields were at ambient levels. Serum melatonin was analyzed by radioimmunoassay (RIA) from 6618 blood samples collected at 0.5 to 3-hour intervals over eight 48-hour periods. Serum progesterone was analyzed by RIA from blood samples collected twice weekly. Serum cortisol was also assayed by RIA from the blood samples collected during the 48-hour samples. Results showed that lambs in both the control and line groups had the typical pattern of melatonin secretion consisting of low daytime and high nighttime serum concentrations. There were no statistically significant differences between groups in melatonin levels, or in the phase or duration of the nighttime melatonin elevation. Age at puberty and number of reproductive cycles also did not differ between groups. Serum cortisol showed a circadian rhythm with highest concentrations during the day. There were, however, no differences in cortisol concentrations between groups. Statistical analyses on other biological parameters revealed no differences between groups for body weight gain, wool growth, or behavior.
Elkhair, Nawal M; Hartmann, Helmut
2010-01-01
The identification of the reference values of Stewart variables and the changes in the acid-base status of the blood and urine in relation to the age after acid-load were studied in desert species of camels. 14 healthy young camels (age: 3-5 months) and 22 adult camels (age: 5-8 years) were used to provide the reference and percentile ranges of the Stewart variables. In the experiments, 24 healthy young camels (age: < 3-5 months) were infused with 5M NH4Cl solution (dose: 1.0 ml/kg) through a permanent intravenous catheter. Venous blood and urine samples were collected before infusion (0 hours). After the start of infusion, venous blood samples were collected at 2, 4, 6, 8 and 24 hours, and urine samples were collected at 8, 24 and 48 hours. Blood and urine samples were used for the determination of the various acid-base parameters, including the non-respiratory Stewart variables. The reference range of serum-[strong ion difference = SID3] was 39-52 mmol/l for all age groups. The reference values of serum-[acid total = A-] were between 10-17 mmol/l for all age groups. Serum-[Atotprotein] and -[Atot-albumin] showed a reference range of 19-24 mmol/I and 20-28 mmol/l, respectively. By 2-8 hours after the NH4Cl-load, the Stewart variables (serum-[SID3] and serum-[A(tot-protein)]) decreased significantly, and as a consequence, the blood pH decreased. Generally, the loaded young camels showed a transient moderate hyperchloraemic acidosis with a slight hypoproteinaemic alkalosis. These malfunctions were accompanied by increased renal fractional excretion of chloride and sodium and decreased urine pH. The identified reference values of the Stewart variables can be used for the clinical diagnosis of acid-base disturbances in camels. With the assistance of the non-respiratory Stewart variables ([SID3] and [Atot]), we can detect the determining influence of strong electrolytes (Na+, K+ and Cl-) and weak acids (proteins, Pi) on the physiological and pathological acid-base status of the animals.
Moncrieff, J
1994-03-18
A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.
Vu, David M; Kelly, Dominic; Heath, Paul T; McCarthy, Noel D; Pollard, Andrew J; Granoff, Dan M
2006-07-15
Group C meningococcal conjugate-vaccine effectiveness in the United Kingdom declines from ~90% in the first year to 0% between 1 and 4 years after immunization in infants immunized at 2, 3, and 4 months of age and to 61% in toddlers given a single dose. Confidence intervals are wide, and the extent of protection is uncertain. Serum samples were obtained from children 3-5 years of age who were participants in a preschool booster-vaccine trial. Serum bactericidal activity was measured with human complement. Group C anticapsular antibody concentrations were measured by a radioantigen binding assay. Passive protection was analyzed in an infant rat bacteremia model. Serum samples from UK children who had been immunized 2-3 years earlier as infants or toddlers had higher levels of radioantigen binding, bactericidal activity, and passive protection than did historical control serum samples from unimmunized children (P<.05). A higher proportion of children immunized as infants had serum bactericidal activity titers > or =1 : 4 (considered to be protective) than those immunized as toddlers (61% vs. 24%; P<.01), but there were no significant differences in the proportion of serum samples conferring passive protection (50% and 41%, respectively; P=.4). We found no evidence of lower immunity in children immunized as infants than as toddlers. On the basis of serum bactericidal activity and/or passive protection, 40%-50% of both age groups are protected at 2-3 years after immunization, which was significantly greater than in unimmunized historical controls (<5%).
Daily rhythm of salivary and serum urea concentration in sheep
Piccione, Giuseppe; Foà, Augusto; Bertolucci, Cristiano; Caola, Giovanni
2006-01-01
Background In domestic animals many biochemical and physiological processes exhibit daily rhythmicity. The aim of the present study was to investigate the rhythmic pattern of salivary and serum urea concentrations in sheep. Methods Six 3-year-old female sheep kept in the same environmental conditions were used. Sheep were sampled at 4 hour intervals for 48 consecutive hours starting at 08:00 of the first day and finishing at 04:00 of the second day. Blood samples were collected via intravenous cannulae inserted into the jugular vein; saliva samples were collected through a specific tube, the "Salivette". Salivary and serum urea concentrations were assayed by means of UV spectrophotometer. ANOVA was used to determine significant differences. The single Cosinor procedure was applied to the results showing significant differences over time. Results ANOVA showed a significant effect of time on salivary and serum urea concentrations. Serum and salivary urea peaked during the light phase. In the dark phase serum and salivary urea concentrations decreased, and the diurnal trough occurred at midnight. Cosinor analysis showed diurnal acrophases for salivary and serum urea concentrations. Daily mean levels were significantly higher in the serum than in the saliva. Conclusion In sheep both salivary and serum urea concentrations showed daily fluctuations. Urea is synthesized in the liver and its production is strongly influenced by food intake. Future investigation should clarify whether daily urea rhythms in sheep are endogenous or are simply the result of the temporal administration of food. PMID:17123442
Fox, Maureen; Brieva, Claudia; Moreno, Carlos; MacWilliams, Peter; Thomas, Chet
2008-12-01
The white-footed tamarin (Saguinus leucopus) is an endangered primate that lives in a small forest corridor in northern Colombia, South America. Hematologic and serum biochemistry reference values are important tools in evaluating the health of the white-footed tamarin and serve to promote the survival of this species. The purpose of this study was to establish diagnostically important hematologic and serum biochemistry reference values for healthy white-footed tamarins and to determine whether there was significant variation with respect to age class (juveniles, adults), gender, and housing facility. Blood samples were collected for hematologic and serum biochemistry measurements from 29 wild-caught captive tamarins during February and April 2005, housed at three different facilities in central Colombia. Hematology and serum biochemistry values were similar in adults and juveniles. Female white-footed tamarins had absolute reticulocyte counts that were lower than those of male tamarins and males had lower serum chloride concentrations than female tamarins. Mean values for hemoglobin, mean cell hemoglobin, serum total protein, albumin, glucose, and alkaline phosphatase varied among the three housing facilities. Twenty-two of the 29 tamarins sampled were microfilaria-positive and had significantly higher mean serum alkaline phosphatase concentrations. Among the 29 tamarins sampled in this study, serum values for mean alkaline phosphatase and creatine kinase concentrations were higher than reported values for other mammals. The reference intervals determined in this study were comparable to normal ranges reported for other members of the family Callitrichidae.
Parathyroid hormone related protein concentration in human serum and CSF correlates with age.
Kushnir, Mark M; Peterson, Lisa K; Strathmann, Frederick G
2018-02-01
Parathyroid Hormone-Related Protein (PTHrP) is involved in intracellular calcium (Ca) regulation, and has been demonstrated to participate in regulation of Ca in brain cells, activation of neurons, and modulation of pain. However, there are conflicting reports regarding the presence of PTHrP in CSF. PTHrP and Ca were quantified in paired CSF and serum samples using mass spectrometry-based methods. Associations between PTHrP and Ca concentrations with age, sex and concentrations of nine CSF diagnostic markers in a set of 140 paired serum and CSF patient samples were evaluated. The observed median PTHrP concentration in CSF was 51 times higher than in serum; the median concentration of Ca in CSF was 1.8 times lower than in serum. We observed positive correlation between concentrations of PTHrP in CSF and serum (p=0.013). Distribution of PTHrP concentrations in serum was associated with age (p=0.0068) and the concentrations were higher in women. In samples with serum calcium concentrations within the reference intervals (n=118), central 95% distribution of concentrations for Ca-CSF, PTHrP-serum and PTHrP-CSF were 5.4 (4.5-6.1) mg/dL, 1.2 (0.5-2.5) pmol/L, 62 (22-125) pmol/L, respectively. Our data demonstrate that PTHrP is a normal constituent of human CSF with median concentrations 51 fold higher than in serum. Elevated serum PTHrP concentrations were positively correlated with age and significantly higher in women. Our data suggest that CSF could be a significant source of circulating PTHrP. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Hausmann, Jennifer C; Cray, Carolyn; Hartup, Barry K
2015-09-01
Protein electrophoresis of serum samples from endangered, wild whooping cranes ( Grus americana ) was performed to help assess the health of the only self-sustaining, migratory population in North America. Serum samples from wild adult cranes (n = 22) were taken at Aransas National Wildlife Refuge, Texas, USA during winter. Wild juvenile cranes (n = 26) were sampled at Wood Buffalo National Park, Northwest Territories, Canada, in midsummer. All captive crane samples were acquired from the International Crane Foundation, Baraboo, WI, USA. Captive adult cranes (n = 30) were sampled during annual examinations, and archived serum samples from captive juvenile cranes (n = 19) were selected to match the estimated age of wild juveniles. Wild juveniles had significantly lower concentrations of all protein fractions than wild adults, except for prealbumin and γ globulins. All protein fraction concentrations for wild juveniles were significantly lower compared with captive juveniles, except for prealbumin and γ globulins, which were higher. Wild adults had significantly greater γ globulin concentrations than captive adults. Captive juveniles had significantly lower prealbumin and albumin concentrations and albumin : globulin ratios than captive adults. The higher γ globulin concentrations in wild versus captive cranes are likely because of increased antigenic exposure and immune stimulation. Protein fraction concentrations vary significantly with age and natural history in this species. Reference intervals for serum protein electrophoresis results from captive adult whooping cranes are provided in this study.
Okay, Thelma Suely; Del Negro, Gilda Maria Barbaro; Yamamoto, Lídia; Raiz Júnior, Roberto
2005-01-01
Twenty-four whole blood and serum samples were drawn from an eight year-old heart transplant child during a 36 months follow-up. EBV serology was positive for VCA-IgM and IgG, and negative for EBNA-IgG at the age of five years old when the child presented with signs and symptoms suggestive of acute infectious mononucleosis. After 14 months, serological parameters were: positive VCA-IgG, EBNA-IgG and negative VCA-IgM. This serological pattern has been maintained since then even during episodes suggestive of EBV reactivation. PCR amplified a specific DNA fragment from the EBV gp220 (detection limit of 100 viral copies). All twenty-four whole blood samples yielded positive results by PCR, while 12 out of 24 serum samples were positive. We aimed at analyzing whether detection of EBV-DNA in serum samples by PCR was associated with overt disease as stated by the need of antiviral treatment and hospitalization. Statistical analysis showed agreement between the two parameters evidenced by the Kappa test (value 0.750; p < 0.001). We concluded that detection of EBV-DNA in serum samples of immunosuppressed patients might be used as a laboratory marker of active EBV disease when a Real-Time PCR or another quantitative method is not available.
Yang, Qian; Manicke, Nicholas E.; Wang, He; Petucci, Christopher; Cooks, R. Graham
2013-01-01
A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 μL of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R2>0.95) and reproducibility (RSD ~10 %) were achieved in the concentration ranges from 100 nM to 5 μM for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests. PMID:22760507
Partition of environmental chemicals between maternal and fetal blood and tissues.
Needham, Larry L; Grandjean, Philippe; Heinzow, Birger; Jørgensen, Poul J; Nielsen, Flemming; Patterson, Donald G; Sjödin, Andreas; Turner, Wayman E; Weihe, Pal
2011-02-01
Passage of environmental chemicals across the placenta has important toxicological consequences, as well as for choosing samples for analysis and for interpreting the results. To obtain systematic data, we collected in 2000 maternal and cord blood, cord tissue, placenta, and milk in connection with births in the Faroe Islands, where exposures to marine contaminants is increased. In 15 sample sets, we measured a total of 87 environmental chemicals, almost all of which were detected both in maternal and fetal tissues. The maternal serum lipid-based concentrations of organohalogen compounds averaged 1.7 times those of cord serum, 2.8 times those of cord tissue and placenta, and 0.7 those of milk. For organohalogen compounds detectable in all matrices, a high degree of correlation between concentrations in maternal serum and the other tissues investigated was generally observed (r(2) > 0.5). Greater degree of chlorination resulted in lower transfer from maternal serum into milk. Concentrations of pentachlorbenzene, γ-hexachlorocyclohexane, and several polychlorinated biphenyl congeners with low chlorination were higher in fetal samples and showed poor correlation with maternal levels. Perfluorinated compounds occurred in lower concentrations in cord serum than in maternal serum. Cadmium, lead, mercury, and selenium were all detected in fetal samples, but only mercury showed close correlations among concentrations in different matrices. Although the environmental chemicals examined pass through the placenta and are excreted into milk, partitions between maternal and fetal samples are not uniform.
Detection and zoonotic potential of Trichinella spp. from free-range pig farming in Greece.
Papatsiros, V G; Boutsini, S; Ntousi, D; Stougiou, D; Mintza, D; Bisias, A
2012-06-01
Trichinellosis is a serious parasitic zoonosis, which is widely distributed around the world. Pork meat is still the predominant source of outbreaks of human trichinellosis in many countries. The aim of this study is to examine the impact of Trichinella spp. as an important risk factor on the free-range pig farming sector in Greece. In 2009, during routine testing for the detection of Trichinella larvae at slaughterhouses and the National Reference Laboratory for Parasites (NRL), a total of 826,426 pigs were tested with the magnetic stirrer method for Trichinella spp. at slaughterhouses, including 2,892 samples from free-range pigs. Two positive samples were detected: one positive for Trichinella britovi and one positive for Trichinella spp. (unspecified) in the samples from wild farmed free-range pigs. It is alarming that one of these cases was connected with clinical signs of trichinellosis in five persons of the same family in northeastern Greece, who consumed undercooked pork meat from a free-range pig farm. During 2010, a total number of 1,295,034 pigs were tested with same method, including 4,159 samples from free-range pig farms. Five positive samples for Trichinella spp. (unspecified) were detected from 4,159 free-range pigs tested by the Greek NRL. Moreover, 363 serum samples from free-range pigs were serologically tested with enzyme-linked immunosorbent assay (ELISA). Moreover, 363 serum samples from farmed free-range pigs were serologically tested with ELISA, and 15 samples were found positive. Finally, the present study is the first report of detection of T. britovi in Greece. In conclusion, based on the results of the present study, Trichinella spp. is a high-risk factor for the free-range pig farming in Greece.
Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D
2013-12-01
Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, < Lower Limit of Quantitation (LLQ); range, < LLQ-43.3 mcg/mL). Significant differences and associations were identified between case status and the following: 1) serum oxalic acid and serum HEAA (both OR = 14.6; 95% C I = 2.8-100.9); 2) serum diglycolic acid and urine diglycolic acid (both OR > 999; exact p < 0.0001); and 3) urinary glycolic acid (OR = 0.057; 95% C I = 0.001-0.55). Two CSF sample results were excluded and two from the same case were averaged, yielding eight samples from eight cases. Diglycolic acid was detected in seven (88%) of case CSF samples (median, 2.03 mcg/mL; range, < LLQ, 7.47). Significantly elevated HEAA (serum) and diglycolic acid (serum and urine) concentrations were identified among cases, which is consistent with animal data. Low urinary glycolic acid concentrations in cases may have been due to concurrent AKI. Although serum glycolic concentrations among cases may have initially increased, further metabolism to oxalic acid may have occurred thereby explaining the similar glycolic acid concentrations in cases and controls. The increased serum oxalic acid concentration results in cases versus controls are consistent with this hypothesis. Diglycolic acid is associated with human DEG poisoning and may be a biomarker for poisoning. These findings add to animal data suggesting a possible role for traditional antidotal therapies. The detection of HEAA and diglycolic acid in the CSF of cases suggests a possible association with signs and symptoms of DEG-associated neurotoxicity. Further work characterizing the pathophysiology of DEG-associated neurotoxicity and the role of traditional toxic alcohol therapies such as fomepizole and hemodialysis is needed.
Ozer, A B; Demirel, I; Erhan, O L; Firdolas, F; Ustundag, B
2015-10-01
Serum Brain-Derived Neurotrophic Factor (BDNF) levels are associated with neurotransmission and cognitive functions. The goal of this study was to examine the effect of general anesthesia on BDNF levels. It was also to reveal whether this effect had a relationship with the surgical stress response or not. The study included 50 male patients, age 20-40, who were scheduled to have inguinoscrotal surgery, and who were in the ASA I-II risk group. The patients were divided into two groups according to the anesthesia techniques used: general (GA) and spinal (SA). In order to measure serum BDNF, cortisol, insulin and glucose levels, blood samples were taken at four different times: before and after anesthesia, end of the surgery, and before transferal from the recovery room. Serum BDNF levels were significantly low (p < 0.01), cortisol and glucose levels were higher (p < 0.05 and p < 0.01) in Group GA compared with Group SA. No significant difference was detected between the groups in terms of serum insulin levels. There was no correlation between serum BDNF and the stress hormones. Our findings suggested that general anesthetics had an effect on serum BDNF levels independent of the stress response. In future, BDNF could be used as biochemical parameters of anesthesia levels, but studies with a greater scope should be carried out to present the relationship between anesthesia and neurotrophins.
Nam, H W; Karpyak, V M; Hinton, D J; Geske, J R; Ho, A M C; Prieto, M L; Biernacka, J M; Frye, M A; Weinshilboum, R M; Choi, D-S
2015-01-01
Acamprosate has been widely used since the Food and Drug Administration approved the medication for treatment of alcohol use disorders (AUDs) in 2004. Although the detailed molecular mechanism of acamprosate remains unclear, it has been largely known that acamprosate inhibits glutamate action in the brain. However, AUD is a complex and heterogeneous disorder. Thus, biomarkers are required to prescribe this medication to patients who will have the highest likelihood of responding positively. To identify pharmacometabolomic biomarkers of acamprosate response, we utilized serum samples from 120 alcohol-dependent subjects, including 71 responders (maintained continuous abstinence) and 49 non-responders (any alcohol use) during 12 weeks of acamprosate treatment. Notably, baseline serum glutamate levels were significantly higher in responders compared with non-responders. Importantly, serum glutamate levels of responders are normalized after acamprosate treatment, whereas there was no significant glutamate change in non-responders. Subsequent functional studies in animal models revealed that, in the absence of alcohol, acamprosate activates glutamine synthetase, which synthesizes glutamine from glutamate and ammonia. These results suggest that acamprosate reduces serum glutamate levels for those who have elevated baseline serum glutamate levels among responders. Taken together, our findings demonstrate that elevated baseline serum glutamate levels are a potential biomarker associated with positive acamprosate response, which is an important step towards development of a personalized approach to treatment for AUD. PMID:26285131
Lorente, Leonardo; Martín, María M; Pérez-Cejas, Antonia; Ramos, Luis; Argueso, Mónica; Solé-Violán, Jordi; Cáceres, Juan J; Jiménez, Alejandro; García-Marín, Victor
2018-04-16
Apoptotic changes after cerebral hemorrhage in brain samples of humans have been found. Caspase-cleaved cytokeratin (CCCK)-18 could be detected in the bloodstream during apoptosis. Higher circulating CCCK-18 levels have been associated with 6-month mortality in patients with basal ganglia hemorrhage. The aim of our study was to determine whether there is an association between serum CCCK-18 levels and early mortality of spontaneous intracerebral hemorrhage (SIH) patients. We performed an observational, prospective and multicentre study. There were included patients with severe SIH defined as Glasgow Coma Scale (GCS) lower than 9. We determined serum CCCK-18 levels at the severe SIH diagnosis moment. We found that non-surviving SIH patients (n = 46) showed lower GCS, and higher serum CCCK-18 levels and APACHE-II score than survivor ones (n = 54). In ROC analysis was found that the area under the curve of serum CCCK-18 levels for 30-day mortality prediction was 90% (95% CI 82-95%; p < 0.001). In the multiple logistic regression analysis, we found an association between serum CCCK-18 levels and 30-day mortality (OR 1.034; 95% CI 1.013-1.055; p = 0.002). The novel finding of our study was that there is an association between high serum CCCK-18 levels and 30-day mortality in severe SIH patients.
Sipa1l1 is an early biomarker of liver fibrosis in CCl4-treated rats
Marfà, Santiago; Morales-Ruiz, Manuel; Oró, Denise; Ribera, Jordi; Fernández-Varo, Guillermo; Jiménez, Wladimiro
2016-01-01
ABSTRACT At present, several procedures are used for staging liver fibrosis. However, these methods may involve clinical complications and/or present diagnostic uncertainty mainly in the early stages of the disease. Thus, this study was designed to unveil new non-invasive biomarkers of liver fibrosis in an in vivo model of fibrosis/cirrhosis induction by CCl4 inhalation by using a label-free quantitative LC-MS/MS approach. We analyzed 94 serum samples from adult Wistar rats with different degrees of liver fibrosis and 36 control rats. Firstly, serum samples from 18 CCl4-treated rats were clustered into three different groups according to the severity of hepatic and the serum proteome was characterized by label-free LC-MS/MS. Furthermore, three different pooled serum samples obtained from 16 control Wistar rats were also analyzed. Based on the proteomic data obtained, we performed a multivariate analysis which displayed three main cell signaling pathways altered in fibrosis. In cirrhosis, more biological imbalances were detected as well as multi-organ alterations. In addition, hemopexin and signal-induced proliferation-associated 1 like 1 (SIPA1L1) were selected as potential serum markers of liver fibrogenesis among all the analyzed proteins. The results were validated by ELISA in an independent group of 76 fibrotic/cirrhotic rats and 20 controls which confirmed SIPA1L1 as a potential non-invasive biomarker of liver fibrosis. In particular, SIPA1L1 showed a clear diminution in serum samples from fibrotic/cirrhotic rats and a great accuracy at identifying early fibrotic stages. In conclusion, the proteomic analysis of serum samples from CCl4-treated rats has enabled the identification of SIPA1L1 as a non-invasive marker of early liver fibrosis. PMID:27230648
Serum and urine chromium as indices of chromium status in tannery workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Randall, J.A.; Gibson, R.S.
Serum and urinary Cr levels of a selected group of men exposed to CrIII in four Southern Ontario tanneries were compared with those of men not exposed to Cr. Fasted blood samples were obtained from 72 tannery workers (TW; mean age +/- SD = 36 +/- 12 years) and from 52 controls (CS; mean age +/- SD = 41 +/- 13 years). Serum Cr levels as determined by graphite furnace atomic absorption spectrophotometry were significantly higher (P = 0.0001) for TW (median 0.49 ng/ml, range 0.37-0.81) than for CS (median 0.15 ng/ml, range 0.12-0.20). Urine samples were collected from 49more » TW and 43 CS on a Friday pm and from 42 TW on a Monday am. Urinary creatine (Cre) was determined by the Jaffe reaction. For Friday samples, the median urinary Cr/Cre ratio was significantly higher (P = 0.0001) for TW (median 0.83 ng/mg, range 0.48-1.82) than for CS (median 0.18 ng/mg, range 0.13-0.26). For TW, Cr/Cre was correlated with serum Cr (r = 0.72, P = 0.0001). Neither urinary Cr/Cre nor serum Cr was correlated with length of employment in the tanning industry. There were significant differences in serum Cr levels and urinary Cr/Cre ratios among TW employed in different areas of the tanneries. For TW, the median urinary Cr/Cre ratio for Monday morning samples was significantly lower than for Friday afternoon samples (P = 0.03). These data indicate that CrIII is absorbed and that serum and urine Cr in tannery workers may be indices of Cr exposure and status.« less
Serum and urine chromium as indices of chromium status in tannery workers.
Randall, J A; Gibson, R S
1987-05-01
Serum and urinary Cr levels of a selected group of men exposed to CrIII in four Southern Ontario tanneries were compared with those of men not exposed to Cr. Fasted blood samples were obtained from 72 tannery workers (TW; mean age +/- SD = 36 +/- 12 years) and from 52 controls (CS; mean age +/- SD = 41 +/- 13 years). Serum Cr levels as determined by graphite furnace atomic absorption spectrophotometry were significantly higher (P = 0.0001) for TW (median 0.49 ng/ml, range 0.37-0.81) than for CS (median 0.15 ng/ml, range 0.12-0.20). Urine samples were collected from 49 TW and 43 CS on a Friday pm and from 42 TW on a Monday am. Urinary creatine (Cre) was determined by the Jaffe reaction. For Friday samples, the median urinary Cr/Cre ratio was significantly higher (P = 0.0001) for TW (median 0.83 ng/mg, range 0.48-1.82) than for CS (median 0.18 ng/mg, range 0.13-0.26). For TW, Cr/Cre was correlated with serum Cr (r = 0.72, P = 0.0001). Neither urinary Cr/Cre nor serum Cr was correlated with length of employment in the tanning industry. There were significant differences in serum Cr levels and urinary Cr/Cre ratios among TW employed in different areas of the tanneries. For TW, the median urinary Cr/Cre ratio for Monday morning samples was significantly lower than for Friday afternoon samples (P = 0.03). These data indicate that CrIII is absorbed and that serum and urine Cr in tannery workers may be indices of Cr exposure and status.
Ascertaining serum levels of trace elements in melanoma patients using PIXE and HR-ICPMS
NASA Astrophysics Data System (ADS)
Bernardes, S.; Tabacniks, M. H.; Santos, I. D. A. O.; Oliveira, A. F.; Shie, J. N.; Sarkis, J. E. S.; Oliveira, T.
2014-01-01
Melanoma is a serious and deadly form of skin cancer. However, patients' chances of survival and recovery are considerably increased when it is diagnosed and treated in its early stages. In this study, trace element concentrations in serum samples from patients with melanoma were measured using PIXE (Proton Induced X-ray Emission) and HR-ICPMS (High-Resolution Inductively Coupled Plasma Mass Spectrometry), with the purpose of correlating these concentrations with the disease. Blood samples from 30 melanoma patients and 116 healthy donors were collected at São Paulo Hospital (protocol CEP 1036/08 UNIFESP). Relevant clinical information on the patients has also been included in the statistical analysis. Analysis of the control group showed different P and Mg concentrations in individuals above and below 40 years of age. P, S, Ca, Cu and Zn concentrations in healthy individuals differed according to gender, highlighting the necessity to include age and gender variables in the case-control analysis. There were also differences in K, S, Ca and Se concentrations between the control and melanoma groups.
Association between serum soluble CD30 and serum creatinine before and after renal transplantation.
López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M
2008-11-01
There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.
Abou-Donia, Mohamed B; Abou-Donia, Martha M; ElMasry, Eman M; Monro, Jean A; Mulder, Michel F A
2013-01-01
This descriptive study reports the results of assays performed to detect circulating autoantibodies in a panel of 7 proteins associated with the nervous system (NS) in sera of 12 healthy controls and a group of 34 flight crew members including both pilots and attendants who experienced adverse effects after exposure to air emissions sourced to the ventilation system in their aircrafts and subsequently sought medical attention. The proteins selected represent various types of proteins present in nerve cells that are affected by neuronal degeneration. In the sera samples from flight crew members and healthy controls, immunoglobin (IgG) was measured using Western blotting against neurofilament triplet proteins (NFP), tubulin, microtubule-associated tau proteins (tau), microtubule-associated protein-2 (MAP-2), myelin basic protein (MBP), glial fibrillary acidic protein (GFAP), and glial S100B protein. Significant elevation in levels of circulating IgG-class autoantibodies in flight crew members was found. A symptom-free pilot was sampled before symptoms and then again afterward. This pilot developed clinical problems after flying for 45 h in 10 d. Significant increases in autoantibodies were noted to most of the tested proteins in the serum of this pilot after exposure to air emissions. The levels of autoantibodies rose with worsening of his condition compared to the serum sample collected prior to exposure. After cessation of flying for a year, this pilot's clinical condition improved, and eventually he recovered and his serum autoantibodies against nervous system proteins decreased. The case study with this pilot demonstrates a temporal relationship between exposure to air emissions, clinical condition, and level of serum autoantibodies to nervous system-specific proteins. Overall, these results suggest the possible development of neuronal injury and gliosis in flight crew members anecdotally exposed to cabin air emissions containing organophosphates. Thus, increased circulating serum autoantibodies resulting from neuronal damage may be used as biomarkers for chemical-induced CNS injury.
Lauritzen, Hilde B.; Larose, Tricia L.; Øien, Torbjørn; Odland, Jon Ø.; van de Bor, Margot; Jacobsen, Geir W.; Sandanger, Torkjel M.
2016-01-01
Introduction Perfluoroalkyl substances (PFASs) and organochlorines (OCs) are ubiquitous and persistent in the environment and proposed endocrine disrupting chemicals (EDCs). They can be transferred across the placenta during pregnancy, and studies suggest that the prenatal period may be particularly sensitive for influences on fetal growth and development. Several studies have investigated socio-demographic and pregnancy related factors associated with maternal serum PFAS and OC levels, but few studies have been conducted in time periods with increasing emissions of PFASs and recent emissions of OCs. Methods Serum from 424 pregnant women participating in the NICHD Scandinavian Successive Small-for-gestational Age (SGA) births study was collected in 1986–1988, and analyses of two PFASs and six OCs were conducted. Associations between EDCs and geographic, time dependent, socio-demographic and pregnancy related variables were evaluated by using multivariable linear regression models. Results Previous breastfeeding duration, time since last breastfeeding period, sampling date and country of residence were important factors associated with serum levels of PFOS and PFOA. Smoking status and pre-pregnancy BMI were negatively associated with PFOS, and maternal height was borderline negatively associated with PFOS and PFOA. Glomerular filtration rate (GFR) was negatively associated with PFOS in a sub-sample. Maternal serum levels of OCs were positively associated with maternal age, and negatively associated with previous breastfeeding duration and sampling date. Smoking had a consistently negative association with PCB 118 in a dose-dependent manner. Education level, pre-pregnancy BMI and alcohol consumption varied in importance according to the compound under study. Conclusions Several maternal factors, including potentially modifiable factors, markers of pregnancy physiology and factors also related to perinatal outcomes were associated with EDC levels. Results from this study are relevant to populations with still high PFAS and OC levels, i.e. developing countries. Moreover, we can use this knowledge about associated factors on emerging EDCs with similar properties. PMID:27824939
Do neighbourhoods matter? Neighbourhood disorder and long-term trends in serum cortisol levels.
Dulin-Keita, Akilah; Casazza, Krista; Fernandez, Jose R; Goran, Michael I; Gower, Barbara
2012-01-01
Characteristics associated with low socioeconomic status neighbourhoods may put children at risk for unique chronic stressors that affect cortisol levels. This research sought to explore whether neighbourhood stressor exposure affected serum cortisol levels among children. A total of 148 African and European-American children with an average age of 8.28 years participated in a longitudinal study evaluating ethnic differences in body composition and disease risk. Five waves of data were included in analyses. Mixed modelling was used to explore neighbourhood stressors, which was a composite index of five items for zip code level poverty and physical disorder, and serum cortisol outcomes for the full sample, by race/ethnicity and gender. Adjustments were made for individual level correlates age, pubertal status, gender and total fat mass. Neighborhood disorder was predictive of lower serum cortisol levels among African-American children (p<0.05), such that higher neighbourhood stressor exposure resulted in lower serum cortisol over time compared with individuals in socially ordered neighbourhoods. Neighbourhood disorder was marginally significant and predictive of higher serum cortisol among European-American children (p<0.10). Transition to a higher pubertal status, nested in age was also predictive of lower serum cortisol levels (p<0.01) among European-American children. Children who are exposed to negative socioenvironmental climates over time are more likely to have altered serum cortisol levels. This may be an adaptive mechanism to cope with stress; however, disrupted cortisol levels may have negative effects on general physical and mental health.
Radhakrishnan, V V; Sumi, M G; Reuben, S; Mathai, A; Nair, M D
2003-05-01
Tumour necrosis factor-alpha (TNF-alpha) is regarded as one of the immune factors that can induce demyelination of peripheral nerves in patients with Guillian-Barre syndrome (GBS). This present study was undertaken to find out the role of TNF-alpha and soluble TNF receptors in the pathogenesis of GBS; and to study the effect of intravenous immunoglobulin (ivIg) therapy on the serum TNF-alpha and soluble TNF receptors in patients with GBS. Thirty six patients with GBS in progressive stages of motor weakness were included in this study. The serum TNF-alpha and soluble TNF receptors (TNF-RI, TNF-RII) were measured in the serum samples of these patients before and after ivIg therapy by a sandwich ELISA. Of the 36 patients with GBS, 26 (72.2%) showed elevated serum TNF-alpha levels prior to ivIg therapy. Following a complete course of ivIg therapy there was a progressive decrease in the serum TNF-alpha concentrations in these 26 patients. On the other hand, the soluble TNF receptors, particularly TNF-RII showed an increase in the serum of GBS patients following ivIg therapy. The results indicate that ivIg reduces the serum TNF-alpha concentrations in the GBS patients having elevated levels prior to ivIg therapy. Elevated serum levels of soluble TNF receptors following ivIg therapy may play a protective role by inhibiting the demyelinating effect of TNF-alpha in the peripheral nerves of patients with GBS.
Meta-analysis of serum lactate dehydrogenase and prognosis for osteosarcoma.
Fu, Yucheng; Lan, Tao; Cai, Hongliu; Lu, Anwei; Yu, Wei
2018-05-01
A large number of studies have reported the relationships between serum lactate dehydrogenase (LDH) and prognosis of osteosarcoma. However, the result is still controversial and no consensus has been reached. Therefore, we performed a meta-analysis to evaluate the prognostic role of serum LDH in osteosarcoma patients. We performed the systematic computerized search for eligible articles from PubMed, Embase, and Cochrane databases until December 21, 2017. The pooled hazard ratio (HR) and 95% confidence intervals (CIs) of overall survival (OS) and event-free survival (EFS) were obtained to assess the prognostic value of serum LDH. A total of 18 studies with 2543 osteosarcoma patients were included. Overall, 15 studies assessed the elevated serum LDH level on OS and the pooled HR was 1.87 (95% CI = 1.58-2.20). Meanwhile, the pooled HR to evaluate the relationship between serum LDH and EFS in 9 studies was 1.78 (95% CI = 1.51-2.10). The same results were acquired when these studies were stratified by Enneking stage, geographic region, and sample size. No heterogeneity existed between these subgroups (P > .05). Begg's funnel plot and Egger's test (OS: P = .04; EFS: P = .34) showed that possible publication bias might exist in OS studies. Sensitivity analysis suggested the pooled HR was robust. This meta-analysis demonstrates that elevated serum LDH level is apparently associated with lower EFS rate and serum LDH could be a prognostic biomarker for osteosarcoma patients.
Beta endorphin in serum and follicular fluid of PCOS- and non-PCOS women.
Jaschke, Nikolai; Lunger, Fabian; Wildt, Ludwig; Seeber, Beata
2018-07-01
To compare the concentrations of beta endorphin in serum and follicular fluid (FF) of PCOS- and non-PCOS women. Secondarily, to investigate associations between beta endorphin and other parameters. Fifty-nine women undergoing in vitro fertilization (IVF) were included in the study. Sixteen were stratified to the PCOS group using the Rotterdam criteria. The remaining 43 women served as controls. Follicular fluid was collected during oocyte retrieval and peripheral blood sampling was performed on the same day. Beta endorphin concentrations in serum and follicular fluid, serum levels of insulin, glucose, LH, estradiol and progesterone were measured. Additionally, testosterone was measured before starting the stimulation protocol. There was no difference in beta endorphin levels between PCOS- and non-PCOS women. The concentration of the peptide was higher in serum than in FF, likely due to collection of FF after ovulation induction and corresponding to the early luteal phase. We found a significant correlation between the number of mature Metaphase II (MII) oocytes retrieved and beta endorphin concentration in FF. In women with biochemical hyperandrogenemia, beta endorphin levels in FF correlated with testosterone levels. Beta Endorphin concentrations in serum and FF do not differ between PCOS- and non PCOS-women undergoing IVF. However, together with sex hormones, beta endorphin might play a key role in oocyte maturation.
de Brito, Rita de Cássia Coelho Moraes; Lucena-Silva, Norma; Torres, Leuridan Cavalcante; Luna, Carlos Feitosa; Correia, Jaílson de Barros; da Silva, Giselia Alves Pontes
2016-12-01
To identify markers for earlier diagnosis of severe pneumonia, we assess the correlation between serum cytokine profile of children with different pneumonia severity. In 25 hospitalized children, 7 with mild pneumonia and 18 with severe pneumonia, the serum concentration of 11 cytokines in three sampling times were dosed. Statistical analysis included parametric and non-parametric tests, Pearson correlation and ROC curve for cut-off definition of cytokines. At admission, IL-6 serum levels were high in mild or severe pneumonia, and was associated to vomiting (P = 0.019) in both groups; and also to dyspnea (P = 0.012) and white blood cell count (P = 0.045) in patients with severe pneumonia. IL-10 levels were also high in patients with pneumonia and were associated to lymphocytosis (P = 0.025). The ROC curve of the IL-6:IL-10 serum levels ratio discriminated severe pneumonia cases at admission, and persistence of infection in the third day of antibiotic therapy, with positive predictive values of 93% and 89%, respectively. The balance between IL-6 and IL-10 serum levels showed to be a more discriminative marker for severity definition and evaluation of recovery in patients with pneumonia.
von Berens, Å; Cederholm, T; Fielding, R A; Gustafsson, T; Kirn, D; Laussen, J; Nydahl, M; Travison, T G; Reid, K; Koochek, A
2018-01-01
To examine the potential association between serum 25(OH) vitamin D and the performance on the Short Physical Performance Battery (SPPB) including the sub-components; five repeated chair stands test, 4 meters walk test and balance in older mobility-limited community-dwelling men and women. A cross sectional study was performed in American and Swedish subjects who were examined for potential participation in a combined exercise and nutrition intervention trial. Logistic regression analysis and linear regression analyses were performed to evaluate the association for 25(OH)D with the overall score on the SBBP, chair stand, gait speed and balance. Community-dwelling (mean age 77.6 ± 5.3 years) mobility limited American (n=494) and Swedish (n=116) females (59%) and males. The SPPB (0-12 points) includes chair stand (s), gait speed (m/s) and a balance test. Mobility limitation i.e., SPPB score ≤ 9 was an inclusion criterion. A blood sample was obtained to measure serum 25(OH)vitamin D concentrations. No clear association of 25(OH)D with SPPB scores was detected either when 25(OH)D was assessed as a continuous variable or when categorized according to serum concentrations of <50, 50-75 or <75 nmol/L. However, when analyzing the relationship between 25(OH)D and seconds to perform the chair stands, a significant quadratic relationship was observed. Thus, at serum levels of 25(OH)D above 74 nmol/L, higher concentrations appeared to be advantageous for the chair stand test, whereas for serum levels below 74 nmol/L this association was not observed. This cross- sectional study lacked clear association between serum 25(OH)D and physical performance in mobility limited adults. A potentially interesting observation was that at higher serum levels of 25(OH)D a better performance on the chair stand test was indicated.
Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio
2015-04-07
This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.
Serum Albumin Domain Structures in Human Blood Serum by Mass Spectrometry and Computational Biology.
Belsom, Adam; Schneider, Michael; Fischer, Lutz; Brock, Oliver; Rappsilber, Juri
2016-03-01
Chemical cross-linking combined with mass spectrometry has proven useful for studying protein-protein interactions and protein structure, however the low density of cross-link data has so far precluded its use in determining structures de novo. Cross-linking density has been typically limited by the chemical selectivity of the standard cross-linking reagents that are commonly used for protein cross-linking. We have implemented the use of a heterobifunctional cross-linking reagent, sulfosuccinimidyl 4,4'-azipentanoate (sulfo-SDA), combining a traditional sulfo-N-hydroxysuccinimide (sulfo-NHS) ester and a UV photoactivatable diazirine group. This diazirine yields a highly reactive and promiscuous carbene species, the net result being a greatly increased number of cross-links compared with homobifunctional, NHS-based cross-linkers. We present a novel methodology that combines the use of this high density photo-cross-linking data with conformational space search to investigate the structure of human serum albumin domains, from purified samples, and in its native environment, human blood serum. Our approach is able to determine human serum albumin domain structures with good accuracy: root-mean-square deviation to crystal structure are 2.8/5.6/2.9 Å (purified samples) and 4.5/5.9/4.8Å (serum samples) for domains A/B/C for the first selected structure; 2.5/4.9/2.9 Å (purified samples) and 3.5/5.2/3.8 Å (serum samples) for the best out of top five selected structures. Our proof-of-concept study on human serum albumin demonstrates initial potential of our approach for determining the structures of more proteins in the complex biological contexts in which they function and which they may require for correct folding. Data are available via ProteomeXchange with identifier PXD001692. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Burse, V W; Groce, D F; Caudill, S P; Korver, M P; Phillips, D L; McClure, P C; Lapeza, C R; Head, S L; Miller, D T; Buckley, D J
1994-04-29
We measured the residues of polychlorinated biphenyls (PCBs) in the serum of 23 residents of the New Bedford, Massachusetts, area and from two homogenates each of bluefish and lobsters from the same area. We used congener-specific and total Aroclor quantitative approaches, both of which involved gas chromatography with electron capture detection. Using gas chromatography mass spectrometry (electron ionization mode), we confirmed the presence of PCBs in the combined serum samples and in the aliquots of bluefish and lobsters. In measuring the PCB levels in serum, we found good agreement between the two electron capture detector approaches (r > or = 0.97) when the serum of specific congeners was compared to total Aroclor. We used univariate and multivariate quality control approaches to monitor these analyses. Analytical results for bluefish showed a better agreement between the two techniques than did those for lobsters; however, the small number of samples precluded any statistical comparison. We also measured levels of chlorinated pesticides in the serum samples of two groups of New Bedford residents, those with low PCB levels (< 15 ng/ml) and those with high PCB levels (> or = 15 ng/ml). We found that residents with high PCB levels also tended to have higher levels of hexachlorobenzene (HCB) and 1,1-dichloro-2,2-di-(p-chlorophenyl) ethylene (p,p'-DDE). The higher concentration of all three analytes appears to be influenced by employment in the capacitor industry, by seafood consumption, or both. Using Jaccard measures of similarity and principal component analysis we compared the gas chromatographic patterns of PCBs found in the serum of New Bedford area residents with high serum PCBs with the patterns found in homogenates of lobsters (inclusive of all edible portions except the roe), in homogenates of bluefish fillets taken from local waters, and in serum from goats fed selected technical Aroclors (e.g. Aroclors 1016, 1242, 1254, or 1260). The patterns found in human serum samples were similar to the patterns found in lobster homogenates. Both of these patterns closely resembled patterns found in the serum samples of the goat fed aroclor 1254, as demonstrated by both pattern recognition techniques. In addition, the chromatographic patterns of human serum and of lobsters and bluefish homogenates all indicated the presence of PCBs more characteristic of Aroclors 1016 or 1242.
Polychlorinated biphenyls in umbilical cord serum of newborns from Rio Grande do Sul state, Brazil.
Mohr, Susana; Sifuentes dos Santos, Joice; Schwanz, Thiago Guilherme; Wagner, Roger; Mozzaquatro, Joseane Oliveira; Lorenzoni, Alessandra Scherer; Costabeber, Ijoni Hilda
2015-12-07
Polychlorinated biphenyls (PCBs) are food-chain contaminants that have been shown to contaminate foods worldwide. The newborn are exposed to these organochlorine compounds across the placenta and through breastfeeding. They are proven to be carcinogenic and may contribute to congenital malformation etiology. This study examined levels of five PCB congeners (28, 52, 138, 153 and 180) in umbilical cord serum samples from 148 newborns from Rio Grande do Sul state, Brazil. Serum concentrations of PCBs were analyzed by gas chromatography with electron capture detection and mass spectrometry. Levels of ∑PCBs ranged from 0.35 to 55.17 ng/ml in umbilical cord serum positive samples, and PCB 138 was the most prevalent congener. Only 7.4% of samples presented no PCB congener. Some PCB congener cord serum levels were related to the locale of the mothers' residence, smoking and drinking habits, fruit consumption, and congenital malformation. Copyright © 2015 Elsevier B.V. All rights reserved.
Lin, Zi-Ying; Liang, Zhen-Xing; Zhuang, Pei-Lin; Chen, Jie-Wei; Cao, Yun; Yan, Li-Xu; Yun, Jing-Ping; Xie, Dan; Cai, Mu-Yan
2016-10-12
Serum C-reactive protein (CRP), an acute inflammatory response biomarker, has been recognized as an indicator of malignant disease progression. However, the prognostic significance of CRP levels collected before tumor removal in intrahepatic cholangiocarcinoma requires further investigation. We sampled the CRP levels in 140 patients with intrahepatic cholangiocarcinoma who underwent hepatectomies with regional lymphadenectomies between 2006 and 2013. A retrospective analysis of the clinicopathological data was performed. We focused on the impact of serum CRP on the patients' cancer-specific survival and recurrence-free survival rates. High levels of preoperative serum CRP were significantly associated with well-established clinicopathologic features, including gender, advanced tumor stage, and elevated carcinoembryonic antigen and carbohydrate antigen 19-9 levels (P < 0.05). Univariate analysis demonstrated a significant association between high levels of serum CRP and adverse cancer-specific survival (P = 0.001) and recurrence-free survival (P < 0.001). In patients with stage I/II intrahepatic cholangiocarcinoma, the serum CRP level was a prognostic indicator for cancer-specific survival. In patients with stage I/II or stage III/IV, the serum CRP level was a prognostic indicator for recurrence-free survival (P < 0.05). Additionally, multivariate analysis identified serum CRP level in intrahepatic cholangiocarcinoma as an independent prognostic factor (P < 0.05). We confirmed a significant association of elevated pre-operative CRP levels with poor clinical outcomes for the tested patients with intrahepatic cholangiocarcinoma. Our results indicate that the serum CRP level may represent a useful factor for patient stratification in intrahepatic cholangiocarcinoma management.
Serum androgenic hormones motivate sexual behavior in adolescent boys.
Udry, J R; Billy, J O; Morris, N M; Groff, T R; Raj, M H
1985-01-01
In order to separate hormonal from social effects on adolescent male sexual behavior, serum hormone assays were performed and questionnaire data on sexual motivation and behavior were collected on a representative sample of 102 boys in grades 8, 9, and 10 of a public school system. Free testosterone was a strong predictor of sexual motivation and behavior, with no additional contribution of other hormones. Including measures of pubertal development and age (indexing the effects of social processes) indicated no additional effects. Free testosterone, therefore, appears to affect sexual motivation directly and does not work through the social interpretation of the accompanying pubertal development.
Kumar, Abhinav; Gangadharan, Bevin; Cobbold, Jeremy; Thursz, Mark; Zitzmann, Nicole
2017-09-21
LC-MS and immunoassay can detect protein biomarkers. Immunoassays are more commonly used but can potentially be outperformed by LC-MS. These techniques have limitations including the necessity to generate separate calibration curves for each biomarker. We present a rapid mass spectrometry-based assay utilising a universal calibration curve. For the first time we analyse clinical samples using the HeavyPeptide IGNIS kit which establishes a 6-point calibration curve and determines the biomarker concentration in a single LC-MS acquisition. IGNIS was tested using apolipoprotein F (APO-F), a potential biomarker for non-alcoholic fatty liver disease (NAFLD). Human serum and IGNIS prime peptides were digested and the IGNIS assay was used to quantify APO-F in clinical samples. Digestion of IGNIS prime peptides was optimised using trypsin and SMART Digest™. IGNIS was 9 times faster than the conventional LC-MS method for determining the concentration of APO-F in serum. APO-F decreased across NAFLD stages. Inter/intra-day variation and stability post sample preparation for one of the peptides was ≤13% coefficient of variation (CV). SMART Digest™ enabled complete digestion in 30 minutes compared to 24 hours using in-solution trypsin digestion. We have optimised the IGNIS kit to quantify APO-F as a NAFLD biomarker in serum using a single LC-MS acquisition.
Intrathecal oligoclonal IgG bands are infrequently found in neuro-Behçet's disease.
Saruhan-Direskeneli, Guher; Yentür, S P; Mutlu, Melike; Shugaiv, E; Yesilot, Nilufer; Kürtüncü, M; Akman-Demir, Gulsen
2013-01-01
Oligoclonal bands (OCB) of immunoglobulins (IgG) in the cerebrospinal fluid (CSF) provides an evidence for the humoral response and have been screened in the CSF and serum of patients revealing 5 different patterns. In this study, patients with Behçet's disease (BD) are screened in a larger sample to potentially provide information about the possible role of CSF oligoclonal immunoglobulins in the diagnosis of this disease. Paired CSF and serum samples from 121 consecutive BD patients with neurological complaints (43 women and 78 men) were included in this study. Parenchymal NBD was diagnosed in 74 patients, and 22 patients had cerebral venous sinus thrombosis (CVST); of the remaining patients, 18 had primary headache disorders not directly associated with BD, and 7 had a cerebrovascular event. OCB of IgG were detected by isoelectric focusing on agarose and immunoblotting of matched serum and CSF sample pairs. Intrathecal production of IgG only is considered positive (Pattern 2 or 3). In the whole group, only 8 patients had OCB in the CSF showing pattern 2. All these positive cases had parenchymal neuro-BD (10.8% positive and 78.4% negative in parenchymal neuro-BD group). All other groups were negative. The rare presence of oligoclonal IgG bands in CSF can be utilized as another laboratory finding in the diagnosis of NBD.
Serum Concentrations of Polyfluoroalkyl Compounds in Faroese Whale Meat Consumers
Weihe, Pal; Kato, Kayoko; Calafat, Antonia M.; Nielsen, Flemming; Wanigatunga, Amal A.; Needham, Larry L.; Grandjean, Philippe
2008-01-01
To learn the extent of human exposure to polyfluoroalkyl compounds (PFCs) in a remote fishing population, we measured, in Faroese children and pregnant women, the serum concentrations of nine PFCs, including perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and perfluorononanoate (PFNA), by using on-line solid-phase extraction coupled to isotope dilution high-performance liquid chromatography-tandem mass spectrometry. The serum samples analyzed had been collected between 1993 and 2005 from 103 children 7 years of age, 79 of these children at 14 years of age, and from 12 pregnant women and their children 5 years later. PFOS was detected in all samples analyzed, and both PFOA and PFNA in all but one of the samples. The concentrations found are comparable to those reported elsewhere. Correlations between paired concentrations were poor. However, PFOS and PFNA concentrations correlated well with the frequency of pilot whale dinners and with concentrations of mercury and polychlorinated biphenyls. One whale meal every two weeks increased the PFOS concentration in 14-year olds by about 25% and PFNA by 50%. The high frequency of detection of most PFCs suggests widespread exposure in the Faroe Islands already by the early 1990s, with whale meat being an important source. Synopsis: Pilot whale meat may have been an important source of dietary exposure to PFOS and PFNA among Faroe Islands residents since the 1990s PMID:18767701
Evaluation of the Olympus AU-510 analyser.
Farré, C; Velasco, J; Ramón, F
1991-01-01
The selective multitest Olympus AU-510 analyser was evaluated according to the recommendations of the Comision de Instrumentacion de la Sociedad Española de Quimica Clinica and the European Committee for Clinical Laboratory Standards. The evaluation was carried out in two stages: an examination of the analytical units and then an evaluation in routine work conditions. The operational characteristics of the system were also studied.THE FIRST STAGE INCLUDED A PHOTOMETRIC STUDY: dependent on the absorbance, the inaccuracy varies between +0.5% to -0.6% at 405 nm and from -5.6% to 10.6% at 340 nm; the imprecision ranges between -0.22% and 0.56% at 405 nm and between 0.09% and 2.74% at 340 nm. Linearity was acceptable, apart from a very low absorbance for NADH at 340 nm; and the imprecision of the serum sample pipetter was satisfactory.TWELVE SERUM ANALYTES WERE STUDIED UNDER ROUTINE CONDITIONS: glucose, urea urate, cholesterol, triglycerides, total bilirubin, creatinine, phosphate, iron, aspartate aminotransferase, alanine aminotransferase and gamma-glutamyl transferase.The within-run imprecision (CV%) ranged from 0.67% for phosphate to 2.89% for iron and the between-run imprecision from 0.97% for total bilirubin to 7.06% for iron. There was no carryover in a study of the serum sample pipetter. Carry-over studies with the reagent and sample pipetters shows some cross contamination in the iron assay.
Serum microRNA expression profile as a diagnostic panel for gastric cancer.
Huang, Shengkai; Wang, Jia; Li, Jia; Luo, Qing; Zhao, Mei; Zheng, Limin; Dong, Xianzhe; Chen, Chao; Che, Yiqun; Liu, Ping; Qi, Jun; Huang, Changzhi
2016-09-01
Previously, we identified six miRNAs that are differentially expressed in colorectal cancer compared with healthy controls. Here, we tested them in gastric cancer GC. We performed quantitative RT-PCR on serum samples from 92 patients with gastric cancer and 89 controls for the six miRNAs, and analyzed their risk scores to evaluate the diagnostic value of the serum miRNA profiling system. After a two-phase selection and validation process, five miRNAs were found to significantly differ in expression between gastric cancer samples and control samples, including miR-21, miR-31, miR-92a, miR-181b, and miR-203. Risk score analysis showed that this miRNA panel could distinguish gastric cancer cases from controls with high sensitivity and specificity. Under receiver operating characteristic curves, areas under the curve for tumor identification were 0.933 (95% confidence interval [CI]: 0.86-1.007) for the training set and 0.919 (95% CI: 0.863-0.975) for the validation set-markedly higher than those of carcinoembryonic antigen (0.624) and carbohydrate antigen 19-9 (0.603). The signature of these five miRNAs is a novel and noninvasive biomarker for gastric cancer, and could facilitate and simplify its diagnosis. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Laassri, Majid; Mee, Edward T; Connaughton, Sarah M; Manukyan, Hasmik; Gruber, Marion; Rodriguez-Hernandez, Carmen; Minor, Philip D; Schepelmann, Silke; Chumakov, Konstantin; Wood, David J
2018-06-22
Bovine viral diarrhoea virus (BVDV) is a cattle pathogen that has previously been reported to be present in bovine raw materials used in the manufacture of biological products for human use. Seven lots of trivalent measles, mumps and rubella (MMR) vaccine and 1 lot of measles vaccine from the same manufacturer, together with 17 lots of foetal bovine serum (FBS) from different vendors, 4 lots of horse serum, 2 lots of bovine trypsin and 5 lots of porcine trypsin were analysed for BVDV using recently developed techniques, including PCR assays for BVDV detection, a qRT-PCR and immunofluorescence-based virus replication assays, and deep sequencing to identify and genotype BVDV genomes. All FBS lots and one lot of bovine-derived trypsin were PCR-positive for the presence of BVDV genome; in contrast all vaccine lots and the other samples were negative. qRT-PCR based virus replication assay and immunofluorescence-based infection assay detected no infectious BVDV in the PCR-positive samples. Complete BVDV genomes were generated from FBS samples by deep sequencing, and all were BVDV type 1. These data confirmed that BVDV nucleic acid may be present in bovine-derived raw materials, but no infectious virus or genomic RNA was detected in the final vaccine products. Copyright © 2018 International Alliance for Biological Standardization. All rights reserved.
Lack of correlation between serum soluble Fas/APO-1 levels and autoimmune disease.
Goel, N; Ulrich, D T; St Clair, E W; Fleming, J A; Lynch, D H; Seldin, M F
1995-12-01
To determine whether elevated soluble Fas/APO-1 (sFas/APO-1) levels are associated with either autoimmune disease or evidence of flares in autoimmune disease. Thirty-seven serum samples were retrospectively obtained from normal controls and patients with laboratory evidence of autoimmune disease activity. These samples were assayed for sFas/APO-1 levels by an enzyme-linked immunosorbent assay, and hospital medical records were retrospectively reviewed for clinical and laboratory characteristics of the patients. Soluble Fas/APO-1 levels did not correlate with clinical diagnoses or laboratory abnormalities. The mean and range of sFas/APO-1 levels were similar in systemic lupus erythematosus patients (including those with active disease), patients with other autoimmune diseases, and normal controls. These data strongly suggest that measurement of sFas/APO-1 levels is unlikely to hold clinical value or play a role in the pathogenesis of autoimmune disease.
Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao
2017-11-27
Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.
Detection of a Serum Siderophore by LC-MS/MS as a Potential Biomarker of Invasive Aspergillosis
Carroll, Cassandra S.; Amankwa, Lawrence N.; Pinto, Linda J.; Fuller, Jeffrey D.; Moore, Margo M.
2016-01-01
Invasive aspergillosis (IA) is a life-threatening systemic mycosis caused primarily by Aspergillus fumigatus. Early diagnosis of IA is based, in part, on an immunoassay for circulating fungal cell wall carbohydrate, galactomannan (GM). However, a wide range of sensitivity and specificity rates have been reported for the GM test across various patient populations. To obtain iron in vivo, A. fumigatus secretes the siderophore, N,N',N"-triacetylfusarinine C (TAFC) and we hypothesize that TAFC may represent a possible biomarker for early detection of IA. We developed an ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for TAFC analysis from serum, and measured TAFC in serum samples collected from patients at risk for IA. The method showed lower and upper limits of quantitation (LOQ) of 5 ng/ml and 750 ng/ml, respectively, and complete TAFC recovery from spiked serum. As proof of concept, we evaluated 76 serum samples from 58 patients with suspected IA that were investigated for the presence of GM. Fourteen serum samples obtained from 11 patients diagnosed with probable or proven IA were also analyzed for the presence of TAFC. Control sera (n = 16) were analyzed to establish a TAFC cut-off value (≥6 ng/ml). Of the 36 GM-positive samples (≥0.5 GM index) from suspected IA patients, TAFC was considered positive in 25 (69%). TAFC was also found in 28 additional GM-negative samples. TAFC was detected in 4 of the 14 samples (28%) from patients with proven/probable aspergillosis. Log-transformed TAFC and GM values from patients with proven/probable IA, healthy individuals and SLE patients showed a significant correlation with a Pearson r value of 0.77. In summary, we have developed a method for the detection of TAFC in serum that revealed this fungal product in the sera of patients at risk for invasive aspergillosis. A prospective study is warranted to determine whether this method provides improved early detection of IA. PMID:26974544
Szarvas, Tibor; Reis, Henning; Vom Dorp, Frank; Tschirdewahn, Stephan; Niedworok, Christian; Nyirady, Peter; Schmid, Kurt W; Rübben, Herbert; Kovalszky, Ilona
2016-08-01
PSA-screening detects many cases of clinically non-aggressive prostate cancer (PC) leading to significant overtreatment. Therefore, pre-operatively available prognostic biomarkers are needed to help therapy decisions. Syndecan-1 (SDC1) is a promising prognostic tissue marker in several cancers including PC but serum levels of shedded SDC1-ectodomain (sSDC1) have not been assessed in PC. A total of 150 patients with PC were included in this study (n = 99 serum samples, n = 103 paraffin-embedded samples (FFPE), n = 52 overlap). SDC1 protein expression and cellular localization was evaluated by immunohistochemistry (IHC), while sSDC1 serum concentrations were measured by ELISA. Serum sSDC1 levels were compared to those of MMP7, which is known to be a protease involved in SDC1 ectodomain-shedding. Clinico-pathological and follow-up data were collected and correlated with SDC1 tissue and serum levels. Disease (PC)-specific (DSS) and overall-survival (OS) were primary endpoints. Median follow-up was 167 months in the serum- and 146 months in the FFPE-group. SDC1-reactivity was higher in non-neoplastic prostate glands compared to PC. In addition, cytoplasmatic, but not membranous SDC1 expression was enhanced in PC patients with higher Gleason-score >6 PC (P = 0.016). Soluble SDC1-levels were higher in patients with Gleason-score >6 (P = 0.043) and metastatic disease (P = 0.022) as well as in patients with progressed disease treated with palliative transurethral resection (P = 0.002). In addition, sSDC1 levels were associated with higher MMP7 serum concentration (P = 0.005). In univariable analyses, only sSDC1-levels exhibited a trend to unfavorable DSS (P = 0.077). In a multivariable pre-operative model, high pre-operative sSDC1-level (>123 ng/ml) proved to be an independent marker of adverse OS (P = 0.048) and DSS (P = 0.020). The present study does not confirm the prognostic relevance of SDC1-IHC. The significant higher sSDC1 serum levels in advanced cases of PC, suggest that SDC1 shedding might be involved in PC progression. Additionally, high sSDC1-level proved to be an independent factor of adverse OS and DSS in a multivariable pre-operative model, making evaluation of sSDC1-levels a promising tool for pre-operative risk-stratification and/or therapy monitoring. Prostate 76:977-985, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Van Nguyen, Cuong; Bonsall, David; Ngo, Tue Tri; Carrique-Mas, Juan; Pham, Anh Hong; Bryant, Juliet E.; Thwaites, Guy; Baker, Stephen; Woolhouse, Mark; Simmonds, Peter
2018-01-01
Rodents and bats are now widely recognised as important sources of zoonotic virus infections in other mammals, including humans. Numerous surveys have expanded our knowledge of diverse viruses in a range of rodent and bat species, including their origins, evolution, and range of hosts. In this study of pegivirus and human hepatitis-related viruses, liver and serum samples from Vietnamese rodents and bats were examined by PCR and sequencing. Nucleic acids homologous to human hepatitis B, C, E viruses were detected in liver samples of 2 (1.3%) of 157 bats, 38 (8.1%), and 14 (3%) of 470 rodents, respectively. Hepacivirus-like viruses were frequently detected (42.7%) in the bamboo rat, Rhizomys pruinosus, while pegivirus RNA was only evident in 2 (0.3%) of 638 rodent serum samples. Complete or near-complete genome sequences of HBV, HEV and pegivirus homologues closely resembled those previously reported from rodents and bats. However, complete coding region sequences of the rodent hepacivirus-like viruses substantially diverged from all of the currently classified variants and potentially represent a new species in the Hepacivirus genus. Of the viruses identified, their routes of transmission and potential to establish zoonoses remain to be determined. PMID:29495551
Sandsveden, Malte; Manjer, Jonas
2017-11-01
Previous research has not been conclusive regarding the association between selenium (Se) and breast cancer. This study was conducted to clarify if there is an association between prediagnostic serum Se levels and breast cancer risk. A population based cohort, the Malmö Diet and Cancer Study, was used and linked with the Swedish cancer registry up to 31 December 2013. Our study included 1,186 women with breast cancer and an equal number of controls. Selenium levels were analysed from stored serum samples. The included individuals were divided into quartiles based on Se value and we compared breast cancer cases with controls using logistic regression yielding odds ratios (OR) with 95% confidence intervals. Serum Se was also analysed as a continuous variable regarding breast cancer risk. The analyses were adjusted for established risk factors and stratified on smoking status and body mass index (BMI). When comparing the highest Se quartile with the lowest, the adjusted OR for breast cancer was 0.98 (0.75-1.26). With selenium as a continuous variable the adjusted OR was 1.00 (1.00-1.01) per 10 ng/ml. When comparing the highest with the lowest Se quartile in women with BMI > 25 kg/m 2 the adjusted OR was 0.77 (0.53-1.14). We conclude that it is unlikely that prediagnostic serum selenium is overall associated with breast cancer risk and no modifying effect from BMI or smoking was seen. © 2017 UICC.
Milk and serum standard reference materials for monitoring organic contaminants in human samples.
Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A
2013-02-01
Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.
Milk and serum standard reference materials for monitoring organic contaminants in human samples
Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N. Alan; Heltsley, Rebecca M.; Hoover, Dale; Keller, Jennifer M.; Leigh, Stefan D.; Patterson, Donald G.; Pintar, Adam L.; Sharpless, Katherine E.; Sjödin, Andreas; Turner, Wayman E.; Vander Pol, Stacy S.; Wise, Stephen A.
2016-01-01
Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4′-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis. PMID:23132544
An aptamer nanopore-enabled microsensor for detection of theophylline.
Feng, Silu; Chen, Changtian; Wang, Wei; Que, Long
2018-05-15
This paper reports an aptamer-based nanopore thin film sensor for detecting theophylline in the buffer solution and complex fluids including plant extracts and serum samples. Compared to antibody-based detection, aptamer-based detection offers many advantages such as low cost and high stability at elevated temperatures. Experiments found that this type of sensor can readily detect theophylline at a concentration as low as 0.05µM, which is much lower than the detection limit of current lab-based equipment such as liquid chromatography (LC). Experiments also found that the aptamer-based sensor has good specificity, selectivity, and reasonable reusability with a significantly improved dynamic detection range. By using the same nanopore thin film sensors as the reference sensors to further mitigate the non-specific binding effect, the theophylline in plant extracts and serum has been detected. Only a small amount (~1μL) of plant extracts or serum samples is required to measure theophylline. Its low cost and ease-of-operation make this type of sensor suitable for point-of-care application to monitor the theophylline level of patients in real time. Copyright © 2018 Elsevier B.V. All rights reserved.
Florant, Gregory L; Porst, Heather; Peiffer, Aubrey; Hudachek, Susan F; Pittman, Chris; Summers, Scott A; Rajala, Michael W; Scherer, Philipp E
2004-11-01
Leptin and adiponectin are proteins produced and secreted from white adipose tissue and are important regulators of energy balance and insulin sensitivity. Seasonal changes in leptin and adiponectin have not been investigated in mammalian hibernators in relationship to changes in fat cell and fat mass. We sought to determine the relationship between serum leptin and adiponectin levels with seasonal changes in lipid mass. We collected serum and tissue samples from marmots (Marmota flaviventris) in different seasons while measuring changes in fat mass, including fat-cell size. We found that leptin is positively associated with increasing fat mass and fat-cell size, while adiponectin is negatively associated with increasing lipid mass. These findings are consistent with the putative roles of these adipokines: leptin increases with fat mass and is involved in enhancing lipid oxidation while adiponectin appears to be higher in summer when hepatic insulin sensitivity should be maintained since the animals are eating. Our data suggest that during autumn/winter animals have switched from a lipogenic condition to a lipolytic state, which may include leptin resistance.
Effect of mobile usage on serum melatonin levels among medical students.
Shrivastava, Abha; Saxena, Yogesh
2014-01-01
Exposure to extremely low frequency (ELF) electromagnetic radiations from mobile phones may affect the circadian rhythm of melatonin in mobile users. The study was designed with objective to evaluate the influence of mobile phone on circadian rhythm of melatonin and to find the association if any between the hours of mobile usage with serum melatonin levels. All the volunteers medical students using mobiles for > 2 hrs/day were included in high users group and volunteers who used mobile for ≤ 2 hrs where included in low users group. Both high and low users volunteers were sampled three times in the same day (Morning-3-4 am, Noon 1-2 pm, Evening-5-6 pm) for estimation of serum melatonin levels: Comparsion of sernum melatonin levels in high users and low users were done by Mann Whitney "U" Test. Reduced morning melatonin levels (3-4 am) was observed in high users (> 2 hrs/day) i.e high users had a disturbed melatonin circadian rhythm.There was a negative correlation between melatonin secretion and hours of mobile usages.
Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma
2017-08-01
Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p<0.005), whereas for patients having cholesterol and mixed GS the concentrations were on the lower side. Biliary Ca concentrations of patients were found to be higher than controls, but difference was significant for pigmented GS patients (p>0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of GS. Copyright © 2017 Elsevier B.V. All rights reserved.
Nassiri, Parvin; Zare, Sajad; Monazzam, Mohammad R.; Pourbakht, Akram; Azam, Kamal; Golmohammadi, Taghi
2017-01-01
Introduction: Noise exposure may have anatomical, nonauditory, and auditory influences. Considering nonauditory impacts, noise exposure can cause alterations in the automatic nervous system, including increased pulse rates, heightened blood pressure, and abnormal secretion of hormones. The present study aimed at examining the effect of various sound pressure levels (SPLs) on the serum aldosterone level among rats. Materials and Methods: A total of 45 adult male rats with an age range of 3 to 4 months and a weight of 200 ± 50 g were randomly divided into 15 groups of three. Three groups were considered as the control groups and the rest (i.e., 12 groups) as the case groups. Rats of the case groups were exposed to SPLs of 85, 95, and 105 dBA. White noise was used as the noise to which the rats were exposed. To measure the level of rats’ serum aldosterone, 3 mL of each rat’s sample blood was directly taken from the heart of anesthetized animals by using syringes. The taken blood samples were put in labeled test tubes that contained anticoagulant Ethylenediaminetetraacetic acid. In the laboratory, the level of aldosterone was assessed through Enzyme-linked immunosorbent assay protocol. The collected data were analyzed by the use of Statistical Package for Social Sciences (SPSS) version 18. Results: The results revealed that there was no significant change in the level of rats’ serum aldosterone as a result of exposure to SPLs of 65, 85, and 95 dBA. However, the level of serum aldosterone experienced a remarkable increase after exposure to the SPL of 105 dBA (P < 0.001). Thus, the SPL had a significant impact on the serum aldosterone level (P < 0.001). In contrast, the exposure time and the level of potassium in the used water did not have any measurable influence on the level of serum aldosterone (P = 0.25 and 0.39). Conclusion: The findings of this study demonstrated that serum aldosterone can be used as a biomarker in the face of sound exposure. PMID:28816207
Ekselius, L; Bengtsson, F; von Knorring, L
2000-09-01
Inadequate compliance of drug intake is an important cause of ineffective pharmacotherapy and has been associated with therapeutic failure. We hypothesized that sensation seeking personality traits would affect compliance with long-term antidepressant medication. Three hundred and eight depressed patients participating in a randomized double-blind study of sertraline and citalopram were included. Personality traits were assessed using the Karolinska Scales of Personality. Compliance to medication was determined in two ways, by means of tablet counting and by measurement concentration of drug in serum. Tablet non-compliance was defined as less than 80% or more than 100% intake of the prescribed drug during weeks 20-24. Serum drug non-compliance was defined as undetectable amounts of either drug and main metabolite in the serum samples at week 24. Two virtually not overlapping groups of non-compliant patients were identified, where those regarded as non-compliant due to the interpretation of the serum drug levels were in majority. The group of serum drug non-compliant patients were recognized by significantly higher scores on the Monotony Avoidance scale and the Impulsive Sensation Seeking Psychopathy factor. The need for better methods than tablet counting and patient questioning to ascertain compliance is emphasized.
The Role of Trace Elements in Tinnitus.
Yaşar, Mehmet; Şahin, Mehmet İlhan; Karakükçü, Çiğdem; Güneri, Erhan; Doğan, Murat; Sağıt, Mustafa
2017-03-01
In this study, we aimed to investigate the role of three trace elements, namely, zinc, copper, and lead, in tinnitus by analyzing the serum level of copper and lead and both the serum and tissue level of zinc. Eighty patients, who applied to outpatient otolaryngology clinic with the complaints of having tinnitus, and 28 healthy volunteers were included. High-frequency audiometry was performed, and participants who had hearing loss according to the pure tone average were excluded; tinnitus frequency and loudness were determined and tinnitus reaction questionnaire scores were obtained from the patients. Of all the participants, serum zinc, copper, and lead values were measured; moreover, zinc levels were examined in hair samples. The levels of trace elements were compared between tinnitus and control groups. The level of copper was found to be significantly lower in the tinnitus group (p = 0.02), but there was no significant difference between the groups in terms of the levels of zinc, neither in serum nor in hair, and lead in serum (p > 0.05). The lack of trace elements, especially that of "zinc," have been doubted for the etiopathogenesis of tinnitus in the literature; however, we only found copper levels to be low in patients having tinnitus.
Association of serum uric acid level and blood pressure in type 2 diabetes mellitus
NASA Astrophysics Data System (ADS)
Savira, M.; Rusdiana; Syahputra, M.
2018-03-01
Uric acid is an end product of purine degradation in humans and primarily excreted through urine. In adulthood, concentrations rise steadily over time and vary with height, body weight, blood pressure, renal function, and alcohol intake. Uric acid is known as anti-oxidant, it has a beneficial role in diseases. Elevated serum uric acid associated with anincreased risk of cardiovascular disease. It has been found that elevated levels of uric acid associated with high risks of acomplication of type 2 diabetes mellitus and It has astrong association between elevated uric acid levels and obesity, metabolic syndrome, diabetes mellitus, hypertension, cardiovascular and renal disorders. The aim of the study analyzed the association between serum uric acid level and blood pressure in type 2 diabetes mellitus patients. This research is descriptive analytic research with a cross sectional design included 50 diabetic subjects aged over 40 years old. Subjects picked by consecutive sampling then we examined the weight, height, waist size, blood pressure, fasting blood sugar, and serum uric acid level. Statistical analysis using chi-square found that there was no significant association between serum uric acid level and systole and diastole pressure in type 2 diabetes mellitus patients (p>0.005).
Kuračka, Lubomír; Kalnovičová, Terézia; Kucharská, Jarmila; Turčáni, Peter
2014-01-01
In the pathogenesis of demyelinating diseases including multiple sclerosis (MS) an important role is played by oxidative stress. Increased energy requirements during remyelination of axons and mitochondria failure is one of the causes of axonal degeneration and disability in MS. In this context, we analyzed to what extent the increase in purine catabolism is associated with selected blood lipophilic antioxidants and if there is any association with alterations in serum levels of coenzyme Q10. Blood serum and cerebrospinal fluid (CSF) samples from 42 patients with diagnosed MS and 34 noninflammatory neurologic patients (control group) were analyzed. Compared to control group, MS patients had significantly elevated values of all purine nucleotide metabolites, except adenosine. Serum lipophilic antioxidants γ -tocopherol, β -carotene, and coenzyme Q10 for the vast majority of MS patients were deficient or moved within the border of lower physiological values. Serum levels of TBARS, marker of lipid peroxidation, were increased by 81% in the MS patients. The results indicate that the deficit of lipophilic antioxidants in blood of MS patients may have a negative impact on bioenergetics of reparative remyelinating processes and promote neurodegeneration.
Wang, Shu-Xia; Zhang, Jia-Ming; Wu, Kai; Chen, Juan; Shi, Jian-Feng
2014-08-01
To investigate the pathogenic infection and its drug resistance in expressed prostatic secretion (EPS) and its correlation with serum PSA, and provide some evidence for the systematic and normalized diagnosis and treatment of prostatitis. Three EPS swabs were collected from each of the 320 prostatis patients following measurement of the serum PSA level, 1 for bacterial culture and identification, 1 for detection of Mycoplasma and drug sensitivity, and the other for examination of Chlamydia trachomatis antigen by colloidal gold immunoblot. Totally 244 strains were isolated from the 320 EPS samples, including 188 bacterial strains (dominated by Staphylococcus and sensitive to vancomycin or linezolid) and 44 Mycoplasma and Chlamydia strains (mainly Ureaplasma urealyticum and susceptible to josamycin or doxycycline). The serum PSA level was significantly higher in the pathogen-positive than in the pathogen-negative group ([6.98 +/- 0.56] microg/L vs [2.32 +/- 0.12] microg/L, P < 0.05). Prostatitis may lead to the elevation of the serum PSA level and the pathogens involved vary in their resistance to different antibacterial spectrums. Therefore, appropriate and individualized antibiotic therapy should be selected according to etiological diagnosis and the results of drug sensitivity test.
Hansen, Jessica; Slechta, E. Susan; Gates-Hollingsworth, Marcellene A.; Neary, Brandon; Barker, Adam P.; Bauman, Sean; Kozel, Thomas R.
2013-01-01
Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results. PMID:23114703
Hansen, Jessica; Slechta, E Susan; Gates-Hollingsworth, Marcellene A; Neary, Brandon; Barker, Adam P; Bauman, Sean; Kozel, Thomas R; Hanson, Kimberly E
2013-01-01
Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results.
Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen
2016-07-01
Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.
Li, Xiao; Tan, Jie; Yu, Jiekai; Feng, Jiandong; Pan, Aiwu; Zheng, Shu; Wu, Jianmin
2014-11-07
Small peptides in serum are potential biomarkers for the diagnosis of cancer and other diseases. The identification of peptide biomarkers in human plasma/serum has become an area of high interest in medical research. However, the direct analysis of peptides in serum samples using mass spectrometry is challenging due to the low concentration of peptides and the high abundance of high-molecular-weight proteins in serum, the latter of which causes severe signal suppression. Herein, we reported that porous semiconductor-noble metal hybrid nanostructures can both eliminate the interference from large proteins in serum samples and significantly enhance the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) yields of peptides captured on the nanostructure. Serum peptide fingerprints with high fidelity can be acquired rapidly, and successful discrimination of colorectal cancer patients based on peptide fingerprints is demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.
Serum Adipocytokine Levels as Surrogate Markers for Disease Activity of Crohn's Disease.
Kim, Su Hwan; Jang, Seung Hyeon; Kim, Ji Won; Kim, Byeong Gwan; Lee, Kook Lae; Kim, You Sun; Han, Dong Soo; Kim, Joo Sung
2017-05-01
Determining inflammatory activity is crucial for assessing disease activity and for tailoring therapy in patients with Crohn׳s disease (CD). This study aimed to evaluate adipocytokine levels in patients with CD and to determine whether they can serve as surrogate markers for disease activity. Serum samples and information regarding the clinical features of patients in the CD Network Project registry were collected from March 2009 to February 2012. Patients with CD and disease duration of at least 2 years were enrolled in this study. Fasting serum leptin, adiponectin, obestatin and ghrelin levels were measured, and their correlation with clinical features of the patients was analyzed. Serum adipocytokine levels were evaluated according to disease activity as determined by CD activity index score. A total of 153 patients with CD were included. Serum ghrelin levels negatively correlated with patient age (P = 0.041) and age at diagnosis (P = 0.017), and positively correlated with C-reactive protein (CRP) levels (P = 0.017). Multiple regression analysis showed that serum ghrelin levels were related only to CRP levels (P = 0.032). Like ghrelin, serum leptin levels were also related to CRP levels (P < 0.001). Obestatin and adiponectin levels were not related to CRP levels. Serum adipocytokine levels did not significantly differ across different disease locations or behaviors. Serum ghrelin levels were significantly lower in patients with CD with a history of surgery than in those without (P = 0.007). Serum ghrelin and leptin levels may be useful as surrogate markers for disease activity in patients with CD. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.
Xia, Xiaoyan; Carroll-Haddad, Alesia; Brown, Nicole; Utell, Mark J.; Mallon, Timothy; Hopke, Philip K.
2016-01-01
Objective The objectives were: 1) measure polycyclic aromatic hydrocarbons (PAHs), polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in 100 μL of human serum and 2) assess PAH and PCDD/PCDF as markers of burn pit exposures during military deployments. Methods PAHs and PCDDs/PCDFs were analyzed in 100μL serum samples collected pre- and post-deployment from 200 persons deployed to Iraq or Afghanistan (CASE); 200 persons not deployed (CONTROL) with GC/MS. Results Naphthalene was found in ~83% of the samples and was statistically different between post-deployment CASE personnel and pre-deployment. 1,2,3,4,6,7,8-Heptachlorodibenzo-p-dioxin, Octachlorodibenzo-p-dioxin, 1,2,3,7,8,9-Hexachlorodibenzofuran, and 1,2,3,4,6,7,8-Heptachlorodibenzofuran were found in ~38% of samples. Concentrations were significantly different between CASE and CONTROL and between pre- and post-deployment samples. Conclusions PAH and PCDD/PCDF in serum can serve as exposure markers and measurements in small volumes is feasible for quantifying exposure to burn pits. PMID:27501107
Jara, Rocio F.; Sepúlveda, Carolina; Ip, Hon S.; Samuel, Michael D.
2015-01-01
Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.
Jara, Rocío F; Sepúlveda, Carolina; Ip, Hon S; Samuel, Michael D
2015-04-01
Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.
Akiyama, Tomoyuki; Hayashi, Yumiko; Hanaoka, Yoshiyuki; Shibata, Takashi; Akiyama, Mari; Tsuchiya, Hiroki; Yamaguchi, Tokito; Kobayashi, Katsuhiro
2017-09-01
We quantified pyridoxal 5'-phosphate (PLP), pyridoxal (PL), and 4-pyridoxic acid (PA) in paired serum and cerebrospinal fluid (CSF) samples from children and investigated the effect of age on the concentrations and CSF-to-serum ratios of these vitamers. Serum and CSF samples prospectively collected from 49 pediatric patients were analyzed. PLP, PL, and PA were measured using high-performance liquid chromatography with fluorescence detection, using pre-column derivatization by semicarbazide. Effects of age on these vitamers, the PLP-to-PL ratio, CSF-to-serum PLP ratio, and CSF-to-serum PL ratio were evaluated using correlation analysis. The PLP, PL, and PA concentrations in the serum and CSF were higher at younger ages, except for CSF PA concentrations that were mostly below the limit of detection (<1.2nmol/l). The PLP-to-PL ratios in the serum and CSF correlated positively with age. The CSF-to-serum PLP ratio and CSF-to-serum PL ratio were independent of age. Age-related changes in PLP, PL, and PA in serum and in CSF from pediatric patients and CSF-to-serum ratios of PLP and PL demonstrated in this study will provide valuable information for evaluating PLP supply to the central nervous system from the peripheral blood. Copyright © 2017 Elsevier B.V. All rights reserved.
Cheadle, M A; Lindsay, D S; Greiner, E C
2006-06-01
Serum was collected from laboratory-reared Virginia opossums (Didelphis virginiana) to determine whether experimentally infected opossums shedding Sarcocystis neurona sporocysts develop serum antibodies to S. neurona merozoite antigens. Three opossums were fed muscles from nine-banded armadillos (Dasypus novemcinctus), and 5 were fed muscles from striped skunks (Mephitis mephitis). Serum was also collected from 26 automobile-killed opossums to determine whether antibodies to S. neurona were present in these opossums. Serum was analyzed using the S. neurona direct agglutination test (SAT). The SAT was modified for use with a filter paper collection system. Antibodies to S. neurona were not detected in any of the serum samples from opossums, indicating that infection in the opossum is localized in the small intestine. Antibodies to S. neurona were detected in filter-paper-processed serum samples from 2 armadillos naturally infected with S. neurona.
Evaluation of a Serum Lung Cancer Biomarker Panel.
Mazzone, Peter J; Wang, Xiao-Feng; Han, Xiaozhen; Choi, Humberto; Seeley, Meredith; Scherer, Richard; Doseeva, Victoria
2018-01-01
A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results.
Evaluation of a Serum Lung Cancer Biomarker Panel
Mazzone, Peter J; Wang, Xiao-Feng; Han, Xiaozhen; Choi, Humberto; Seeley, Meredith; Scherer, Richard; Doseeva, Victoria
2018-01-01
Background: A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. Methods: The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. Results: The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. Conclusions: This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results. PMID:29371783
Nutrititional Status Assessment of International Space Station Crew Members
NASA Technical Reports Server (NTRS)
Smith, S. M.; Zwart, S. R.; Block, G.; Rice, B. I.; Davis-Street, J. F.
2005-01-01
Defining optimal nutrient requirements is imperative to ensure crew health on long-duration space exploration missions. To date, nutrient requirement data have been extremely limited because of small sample sizes and difficulties associated with collecting biological samples. In this study, we examined changes in body composition, bone metabolism, hematology, general blood chemistry, and blood levels of selected vitamins and minerals after long-duration (128-195 d) space flight aboard the International Space Station. Crew members consumed an average of 80% of the recommended energy intakes, and on landing day their body weight had decreased (P=0.051). After flight, hematocrit was less, and serum femtin was greater than before flight (P<0.01). Serum iron, ferritin saturation, and transferrin had decreased after flight. The finding that other acute-phase proteins, including ceruloplasmin, retinol binding protein, transthyretin, and albumin were not changed after flight suggests that the changes in iron metabolism may not be strictly due to an inflammatory response. Urinary 8- hydroxy-2'-deoxyguanosine concentration was greater and superoxide dismutase was less after flight, indicating that oxidative damage had increased (P<0.05). Despite the reported use of vitamin D supplements during flight, serum 25-hydroxyvitamin D was significantly decreased after flight (P<0.01). Bone resorption was increased after flight, as indicated by several urinary markers of bone resorption. Bone formation, assessed by serum concentration of bone-specific alkaline phosphatase, was elevated only in crew members who landed in Russia, probably because of the longer time lapse between landing and sample collection. These data provide evidence that bone loss, compromised vitamin D status, and oxidative damage remain critical concerns for long-duration space flight.
Protein Turnover Measurements in Human Serum by Serial Immunoaffinity LC-MS/MS.
Farrokhi, Vahid; Chen, Xiaoying; Neubert, Hendrik
2018-02-01
The half-life of target proteins is frequently an important parameter in mechanistic pharmacokinetic and pharmacodynamic (PK/PD) modeling of biotherapeutics. Clinical studies for accurate measurement of physiologically relevant protein turnover can reduce the uncertainty in PK/PD model-based predictions, for example, of the therapeutic dose and dosing regimen in first-in-human clinical trials. We used a targeted mass spectrometry work flow based on serial immunoaffinity enrichment ofmultiple human serum proteins from a [5,5,5- 2 H 3 ]-L-leucine tracer pulse-chase study in healthy volunteers. To confirm the reproducibility of turnover measurements from serial immunoaffinity enrichment, multiple aliquots from the same sample set were subjected to protein turnover analysis in varying order. Tracer incorporation was measured by multiple-reaction-monitoring mass spectrometry and target turnover was calculated using a four-compartment pharmacokinetic model. Five proteins of clinical or therapeutic relevance including soluble tumor necrosis factor receptor superfamily member 12A, tissue factor pathway inhibitor, soluble interleukin 1 receptor like 1, soluble mucosal addressin cell adhesion molecule 1, and muscle-specific creatine kinase were sequentially subjected to turnover analysis from the same human serum sample. Calculated half-lives ranged from 5-15 h; however, no tracer incorporation was observed for mucosal addressin cell adhesion molecule 1. The utility of clinical pulse-chase studies to investigate protein turnover can be extended by serial immunoaffinity enrichment of target proteins. Turnover analysis from serum and subsequently from remaining supernatants provided analytical sensitivity and reproducibility for multiple human target proteins in the same sample set, irrespective of the order of analysis. © 2017 American Association for Clinical Chemistry.
Serum Proteome Profiles in Stricturing Crohn’s Disease: A pilot study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Townsend, Peter; Zhang, Qibin; Shapiro, Jason
Background: Crohn’s disease (CD) is a form of inflammatory bowel disease (IBD) with different described behaviors, including stricture. At present, there are no laboratory studies that can differentiate stricturing CD from other phenotypes of IBD. We performed a pilot study to examine differences in the proteome among patients with stricturing Crohn’s disease, non-stricturing Crohn’s disease, and ulcerative colitis (UC). Methods: Serum samples were selected from the Ocean State Crohn’s and Colitis Area Registry (OSCCAR), an established cohort of patients with IBD. Crohn’s disease patients with surgically-resected stricture were matched with similar patients with Crohn’s disease without known stricture, and withmore » UC. Serum samples from each patient were digested and analyzed using liquid chromatography-mass spectrometry to characterize the proteome. Statistical analyses were performed to identify peptides and proteins that can differentiate CD with stricture. Results: Samples from 9 patients in each group (27 total patients) were analyzed. Baseline demographic characteristics were similar among the three groups. We quantified 7668 peptides and 897 proteins for analysis. ROC analysis identified a subset of peptides with an area under the curve greater than 0.9, indicating greater separation potential. Partial least squares discriminant analysis was able to distinguish among the three groups with up to 70% accuracy by peptides, and up to 80% accuracy by proteins. We identified the significantly different proteins and peptides, and determined their function based on previously published literature. Conclusions: The serum of patients with stricturing CD, non-stricturing CD, and UC are distinguishable via proteomic analysis. Some of the proteins that differentiate the stricturing phenotype have been implicated in complement activation, fibrinolytic pathways, and lymphocyte adhesion.« less
NASA Astrophysics Data System (ADS)
Farnoudian-Habibi, Amir; Massoumi, Bakhshali; Jaymand, Mehdi
2016-11-01
A novel and efficient strategy for the simultaneous determination of two tricyclic antidepressant (TCA) drugs [amitriptyline (AT), and its main metabolite (nortriptyline; NT)] via a combination of magnetic solid phase extraction (MSPE), and spectrophotometric techniques in serum is suggested. For this purpose, the imidazolium ionic liquid (Imz)-modified Fe3O4@SiO2 nanoparticles (Fe3O4@SiO2-Imz) was employed as an adsorbent for the MSPE. Preconcentration (loading-desorption) studies were performed under optimized conditions including pH, adsorbent amount, contact time, eluent volume, and desorption time. Afterward, determination of each drug was carried out by specific strategy. Acetaldehyde (AC), and 2,3,5,6-tetrachloro-1,4-benzoquinone (chloranil; CL) were used as chemical reagents for reaction with NT, while AT did not react with these reagents. This method is based on the condensation reaction between secondary amine group of NT and AC to afford an enamine, and subsequently reaction with CL to produce a chlorinated quinone-substituted enamine. The final product exhibited maximum absorption at 556 nm, while the AT was determined at 240 nm. The limits of detections (LODs) for NT and AT in serum sample were obtained as 0.19 and 0.90 ng mL- 1, respectively. The limits of quantifications (LOQs) were obtained to be 0.63 and 2.93 ng mL- 1 for NT and AT, respectively. A linear range was obtained to be 1 to 5 ng mL- 1. Results indicated that the suggested method is applicable for simultaneous determination of NT and AT in serum samples.
Jager, Alessandra V; Tonin, Fernando G; Baptista, Gabriela Z; Souto, Pollyana C M C; Oliveira, Carlos A F
2016-05-01
The aim of this study was to evaluate the human exposure of individuals from Pirassununga, Brazil, to dietary aflatoxins B1 (AFB1) and M1 (AFM1) by determination of serum AFB1-lysine and urinary aflatoxin biomarkers (AFM1 and AFB1-N(7)-guanine). The participants were recruited among employees from a Campus of the University of São Paulo, which provided food samples from their homes, as well as serum and urine samples four times every three months, from June 2011 until March 2012. The probable daily intake (PDI) of aflatoxin was estimated by using the results from analysis of food products collected by the time of samples collection, and data from a 24-hour dietary recall questionnaire. Analyses of AFB1 and AFM1 in food samples were conducted by high-performance liquid chromatography with fluorescence detection. Biomarkers in serum and urine were determined by tandem mass spectrometry. AFB1 and AFM1 were detected in 38 samples of cereals (28%, N=136) and 31 milk products (36%, N=86), respectively. AFB1-lysine and AFB1-N(7)-guanine and were not detected in serum or urine samples, respectively. However, AFM1 was found in 74 urine samples (65%), at mean levels in the 4 sampling times ranging from 0.37±0.23 to 1.70±2.88pg/mg creatinine. The mean PDI varied among different sampling times, ranging from 0.09±0.09 to 1.35±5.98ng/kg body weight/day. A modest though significant correlation (r=0.45; p=0.03; N=23) was found for the first time in Brazil between the AFM1 concentration in urine and the PDI for total aflatoxins (AFB1+AFM1) in sampling 1 (June 2011). Urinary AFM1 was confirmed as very sensitive for monitoring the human exposure to dietary aflatoxin. Further studies using serum and urinary biomarkers are needed to estimate the aflatoxin exposure of populations in higher risk areas in Brazil. Copyright © 2015 Elsevier GmbH. All rights reserved.
Maslin, Jérôme; Rogier, Christophe; Berger, Franck; Khamil, Mohamed Ali; Mattera, Didier; Grandadam, Marc; Caron, Mélanie; Nicand, Elizabeth
2005-06-01
During a national survey in 2002 in Djibouti, serum samples were collected using a valid sampling scheme from 2423 Djiboutians representing the general population of urban and rural districts. The HIV-1 seroprevalence was 2%. The HIV-1 polymerase gene from 53 untreated patients was amplified. Phylogenetic analysis of 34 isolates revealed a majority of subtype C (73%) as well as other subtypes, including CRF02_AG recombinants (18%), subtype D (6%), and subtype A (3%).
Urine phenobarbital drug screening: potential use for compliance assessment in neonates.
Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P
2012-02-01
This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.
Occurrence of West Nile virus antibodies in wild birds, horses, and humans in Poland.
Niczyporuk, Jowita Samanta; Samorek-Salamonowicz, Elżbieta; Lecollinet, Sylvie; Pancewicz, Sławomir Andrzej; Kozdruń, Wojciech; Czekaj, Hanna
2015-01-01
Serum samples of 474 wild birds, 378 horses, and 42 humans with meningitis and lymphocytic meningitis were collected between 2010 and 2014 from different areas of Poland. West Nile virus (WNV) antibodies were detected using competition enzyme linked immunosorbent assays: ELISA-1 ID Screen West Nile Competition, IDvet, ELISA-2 ID Screen West Nile IgM Capture, and ELISA-3 Ingezim West Nile Compac. The antibodies were found in 63 (13.29%) out of 474 wild bird serum samples and in one (0.26%) out of 378 horse serum samples. Fourteen (33.33%) out of 42 sera from patients were positive against WNV antigen and one serum was doubtful. Positive samples obtained in birds were next retested with virus microneutralisation test to confirm positive results and cross-reactions with other antigens of the Japanese encephalitis complex. We suspect that positive serological results in humans, birds, and horses indicate that WNV can be somehow closely related with the ecosystem in Poland.
Occurrence of West Nile Virus Antibodies in Wild Birds, Horses, and Humans in Poland
Niczyporuk, Jowita Samanta; Samorek-Salamonowicz, Elżbieta; Lecollinet, Sylvie; Pancewicz, Sławomir Andrzej; Kozdruń, Wojciech; Czekaj, Hanna
2015-01-01
Serum samples of 474 wild birds, 378 horses, and 42 humans with meningitis and lymphocytic meningitis were collected between 2010 and 2014 from different areas of Poland. West Nile virus (WNV) antibodies were detected using competition enzyme linked immunosorbent assays: ELISA-1 ID Screen West Nile Competition, IDvet, ELISA-2 ID Screen West Nile IgM Capture, and ELISA-3 Ingezim West Nile Compac. The antibodies were found in 63 (13.29%) out of 474 wild bird serum samples and in one (0.26%) out of 378 horse serum samples. Fourteen (33.33%) out of 42 sera from patients were positive against WNV antigen and one serum was doubtful. Positive samples obtained in birds were next retested with virus microneutralisation test to confirm positive results and cross-reactions with other antigens of the Japanese encephalitis complex. We suspect that positive serological results in humans, birds, and horses indicate that WNV can be somehow closely related with the ecosystem in Poland. PMID:25866767
Zheng, Xiaoyang; Baker, Haven; Hancock, William S
2006-07-07
Advances in proteomics are continuing to expand the ability to analyze the serum proteome. In recent years, it has been realized that in addition to the circulating proteins, human serum also contains a large number of peptides. Many of these peptides are believed to be fragments of larger proteins that have been at least partially degraded by various enzymes such as metalloproteases. Identifying these peptides from a small amount of serum/plasma is difficult due to the complexity of the sample, the low levels of these peptides, and the difficulties in getting a protein identification from a single peptide. In this study, we modified previously published protocols for using centrifugal ultrafiltration, and unlike past studies did not digest the filtrate with trypsin with the intent of identifying endogenous peptides with this method. The filtrate fraction was concentrated and analyzed by a reversed phase-high performance liquid chromatography system connected to a nanospray ionization hybrid ion trap-Fourier transform mass spectrometer (LTQ-FTMS). The mass accuracy of this instrument allows confidence for identifying the protein precursors by a single peptide. The utility of this approach was demonstrated by the identification of over 300 unique peptides with 2 ppm or better mass accuracy per serum sample. With confident identifications, the origin and function of native serum peptides can be more seriously explored. Interestingly, over 34 peptide ladders were observed from over 17 serum proteins. This indicates that a cascade of proteolytic processes affects the serum peptidome. To examine whether this result was an artifact of serum, matched plasma and serum samples were analyzed with similar peptide ladders found in each.
Tan, Zhijing; Yin, Haidi; Nie, Song; Lin, Zhenxin; Zhu, Jianhui; Ruffin, Mack T; Anderson, Michelle A; Simeone, Diane M; Lubman, David M
2015-04-03
Glycosylation has significant effects on protein function and cell metastasis, which are important in cancer progression. It is of great interest to identify site-specific glycosylation in search of potential cancer biomarkers. However, the abundance of glycopeptides is low compared to that of nonglycopeptides after trypsin digestion of serum samples, and the mass spectrometric signals of glycopeptides are often masked by coeluting nonglycopeptides due to low ionization efficiency. Selective enrichment of glycopeptides from complex serum samples is essential for mass spectrometry (MS)-based analysis. Herein, a strategy has been optimized using LCA enrichment to improve the identification of core-fucosylation (CF) sites in serum of pancreatic cancer patients. The optimized strategy was then applied to analyze CF glycopeptide sites in 13 sets of serum samples from pancreatic cancer, chronic pancreatitis, healthy controls, and a standard reference. In total, 630 core-fucosylation sites were identified from 322 CF proteins in pancreatic cancer patient serum using an Orbitrap Elite mass spectrometer. Further data analysis revealed that 8 CF peptides exhibited a significant difference between pancreatic cancer and other controls, which may be potential diagnostic biomarkers for pancreatic cancer.
Chiem, N H; Harrison, D J
1998-03-01
A glass microchip is described in which reagents and serum samples for competitive immunoassay of serum theophylline can be mixed, reacted, separated, and analyzed. The device functions as an automated microfluidic immunoassay system, creating a lab-on-a-chip. Electroosmotic pumping was used to control first the mixing of 50-fold-diluted serum sample with labeled theophylline tracer in a 1:1 ratio, followed by 1:1 mixing and reaction with anti-theophylline antibody. The 51-nL on-chip mixer gave the same concentration as dilution performed off-chip, within 3%. A 100-pL plug of the reacted solution was then injected into an electrophoresis separation channel integrated within the same chip. Measurements of free and bound tracer by fluorescence detection gave linear calibration curves of signal vs log[theophylline] between 0 and 40 mg/L, with a slope of 0.52 +/- 0.03 and an intercept of -0.04 +/- 0.04 after a 90-s reaction time. A detection limit of 0.26 mg/L in serum (expressed before the dilution step, actual concentration of 1.3 micrograms/L at the detector) was obtained. Recovery values were 107% +/- 8% for 15 mg/L serum samples.
Belz, S; Frickel, C; Wolfrom, C; Nau, H; Henze, G
1994-11-04
A method for the simultaneous determination of the antifolates methotrexate and 7-hydroxymethotrexate as well as the folates 5-methyltetrahydrofolic acid and folinic acid (5-formyltetrahydrofolic acid) in serum and cerebrospinal fluid (CSF) is described. High-performance liquid chromatography with gradient elution and dual detection (ultraviolet absorption and fluorescence) was used to separate and quantitate the analytes. Serum samples containing high levels of the substances of interest and CSF samples were injected directly onto the HPLC column. For determination of low concentrations, serum samples were subjected to a solid-phase extraction method for clean-up and concentration purposes. The determination limits were 10 ng/ml for both antifolates, 100 ng/ml for folinic acid, and 0.1 ng/ml for the physiologically occurring methylated folate which is about 1/100 the serum concentration in healthy children. The suitability of the method for pharmacokinetic monitoring of high-dose methotrexate therapy combined with leucovorin rescue administered to children with acute lymphoblastic leukemia was demonstrated. Minimum values of the serum folate during treatment ranged from 0.2 to 3.1 ng/ml. Even those very low concentrations could be reliably measured.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomson, S.; Wallace, A.M.; Cook, B.
1989-08-01
We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of thesemore » selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.« less
NASA Astrophysics Data System (ADS)
Ivanov, A. I.; Zhbankov, R. G.; Korolenko, E. A.; Korolik, E. V.; Meleshchenko, L. A.; Sarnatskaya, V. V.; Nikolaev, V. G.; Nikolaichik, V. V.; Yushko, L. A.
1997-01-01
Differential scanning calorimetry and IR spectrosocopy were used to investigate the effect of the procedure of isolation of human serum albumin on its physicochemical characteristics. It is shown that fractionation of blood plasma with ethylene glycol followed by ion exchange chromatography can be used to obtain albumin of normal donors that is similar to the albumin in the nonfractionated plasma according to melting thermograms. Endotherms of human serum albumin samples that were obtained by affinity chromatography and preparative electrophoresis are bimodal, unlike the monophasic for albumin obtained by polyethylene glycol precipitation. These changes result from a higher content of nonetherified fatty acids in the albumin samples obtained by affinity chromatography and from modification of the secondary protein structure in the samples obtained by electrophoresis. Analysis of melting thermograms of serum albumin from patients with uremia, chronic hepatitis, and peritonitis shows that fractionation of blood with polyethylene glycol preserves the thermodynamic characteristics of the various pathological serum albumins to the greatest extent. The present results demonstrate the advantage of polyethylene glycol fractionation for isolation of native preparations of normal and “pathological” human serum albumin.
De Groote, Mary A; Sterling, David G; Hraha, Thomas; Russell, Theresa M; Green, Louis S; Wall, Kirsten; Kraemer, Stephan; Ostroff, Rachel; Janjic, Nebojsa; Ochsner, Urs A
2017-10-01
New non-sputum biomarker tests for active tuberculosis (TB) diagnostics are of the highest priority for global TB control. We performed in-depth proteomic analysis using the 4,000-plex SOMAscan assay on 1,470 serum samples from seven countries where TB is endemic. All samples were from patients with symptoms and signs suggestive of active pulmonary TB that were systematically confirmed or ruled out for TB by culture and clinical follow-up. HIV coinfection was present in 34% of samples, and 25% were sputum smear negative. Serum protein biomarkers were identified by stability selection using L1-regularized logistic regression and by Kolmogorov-Smirnov (KS) statistics. A naive Bayes classifier using six host response markers (HR6 model), including SYWC, kallistatin, complement C9, gelsolin, testican-2, and aldolase C, performed well in a training set (area under the sensitivity-specificity curve [AUC] of 0.94) and in a blinded verification set (AUC of 0.92) to distinguish TB and non-TB samples. Differential expression was also highly significant ( P < 10 -20 ) for previously described TB markers, such as IP-10, LBP, FCG3B, and TSP4, and for many novel proteins not previously associated with TB. Proteins with the largest median fold changes were SAA (serum amyloid protein A), NPS-PLA2 (secreted phospholipase A2), and CA6 (carbonic anhydrase 6). Target product profiles (TPPs) for a non-sputum biomarker test to diagnose active TB for treatment initiation (TPP#1) and for a community-based triage or referral test (TPP#2) have been published by the WHO. With 90% sensitivity and 80% specificity, the HR6 model fell short of TPP#1 but reached TPP#2 performance criteria. In conclusion, we identified and validated a six-marker signature for active TB that warrants diagnostic development on a patient-near platform. Copyright © 2017 De Groote et al.
De Groote, Mary A.; Sterling, David G.; Hraha, Thomas; Russell, Theresa M.; Green, Louis S.; Wall, Kirsten; Kraemer, Stephan; Ostroff, Rachel; Janjic, Nebojsa
2017-01-01
ABSTRACT New non-sputum biomarker tests for active tuberculosis (TB) diagnostics are of the highest priority for global TB control. We performed in-depth proteomic analysis using the 4,000-plex SOMAscan assay on 1,470 serum samples from seven countries where TB is endemic. All samples were from patients with symptoms and signs suggestive of active pulmonary TB that were systematically confirmed or ruled out for TB by culture and clinical follow-up. HIV coinfection was present in 34% of samples, and 25% were sputum smear negative. Serum protein biomarkers were identified by stability selection using L1-regularized logistic regression and by Kolmogorov-Smirnov (KS) statistics. A naive Bayes classifier using six host response markers (HR6 model), including SYWC, kallistatin, complement C9, gelsolin, testican-2, and aldolase C, performed well in a training set (area under the sensitivity-specificity curve [AUC] of 0.94) and in a blinded verification set (AUC of 0.92) to distinguish TB and non-TB samples. Differential expression was also highly significant (P < 10−20) for previously described TB markers, such as IP-10, LBP, FCG3B, and TSP4, and for many novel proteins not previously associated with TB. Proteins with the largest median fold changes were SAA (serum amyloid protein A), NPS-PLA2 (secreted phospholipase A2), and CA6 (carbonic anhydrase 6). Target product profiles (TPPs) for a non-sputum biomarker test to diagnose active TB for treatment initiation (TPP#1) and for a community-based triage or referral test (TPP#2) have been published by the WHO. With 90% sensitivity and 80% specificity, the HR6 model fell short of TPP#1 but reached TPP#2 performance criteria. In conclusion, we identified and validated a six-marker signature for active TB that warrants diagnostic development on a patient-near platform. PMID:28794177
Petropoulou, Syrago-Styliani E; Duong, Wendy; Petreas, Myrto; Park, June-Soo
2014-08-22
Hydroxylated polybrominated diphenyl ethers (OH-PBDEs) are formed from the oxidative metabolism of polybrominated diphenyl ethers (PBDEs) in humans, rats and mice, but their quantitation in human blood and other matrices with liquid chromatography-mass spectrometric techniques has been a challenge. In this study, a novel analytical method was developed and validated using only 250 μL of human serum for the quantitation of twelve OH-PBDEs, fully chromatographically separated in a 15 min analytical run. This method includes two novel approaches: an enzymatic hydrolysis procedure and a chromatographic separation using a mixed mode chromatography column. The enzymatic hydrolysis (EH) was found critical for 4'-OH-BDE17, which was not detectable without it. For the sample clean up, a solid phase extraction protocol was developed and validated for the extraction of the 12 congeners from human serum. In addition, for the first time baseline resolution of two components was achieved that correspond to a single peak previously identified as 6'-OH-BDE99. The method was validated for linearity, accuracy, precision, matrix effects, limit of quantification, limit of detection, sample stability and overall efficiency. Recoveries (absolute and relative) ranged from 66 to 130% with relative standard deviations <21% for all analytes. Limit of detection and quantitation ranged from 4 to 90 pg mL(-1) and 6-120 pg mL(-1), respectively, with no carry over effects. This method was applied in ten commercially available human serum samples from the general US population. The mean values of the congeners detected in all samples are 4'-OH-BDE17 (34.2 pg mL(-1)), 4-OH-BDE42 (33.9 pg mL(-1)), 5-OH-BDE47 (17.5 pg mL(-1)) and 4'-OH-BDE49 (12.4 pg mL(-1)). Copyright © 2014 Elsevier B.V. All rights reserved.
Schmidt, Debra A; Koutsos, Elizabeth A; Ellersieck, Mark R; Griffin, Mark E
2009-03-01
Serum concentrations of amino acids, fatty acids, lipoproteins, vitamins A and E, and minerals in zoo giraffes (Giraffa camelopardalis) were compared to values obtained from free-ranging giraffes in an effort to identify potential nutritional differences in the zoo population. Zoo giraffes have a specific set of maladies that may be nutritionally related, including peracute mortality, energy malnutrition, pancreatic disease, urolithiasis, hoof disease, and severe intestinal parasitism. Dietary requirements for giraffes are not known; invasive studies used with domestic animals cannot be performed on zoo animals. Though domestic animal standards are often used to evaluate nutritional health of exotic animals, they may not be the most appropriate standards to use. Serum samples from 20 zoo giraffes at 10 zoological institutions in the United States were compared to previously collected samples from 24 free-ranging giraffes in South Africa. Thirteen of the zoo animal samples were collected from animals trained for blood collection, and seven were banked samples obtained from a previous serum collection. Dietary information was also collected on each zoo giraffe; most zoo giraffe diets consisted of alfalfa-based pellets (acid detergent fiber-16), alfalfa hay, and browse in varying quantities. Differences between zoo and free-ranging giraffes, males and females, and adults and subadults were analyzed with the use of a 2 x 2 x 2 factorial and Fisher's Least Significant Difference (LSD) for mean separation. Of the 84 parameters measured, 54 (60%) were significantly different (P < or = 0.05) between zoo and free-ranging giraffes. Nine (11%) items were significantly different (P < or = 0.05) between adult and subadult animals. Only one parameter, sodium concentration, was found to be significantly different (P < or = 0.05) between genders. Further investigation in zoo giraffe diets is needed to address the differences seen in this study and the potentially related health problems.
Michalke, Bernhard; Kramer, Matthias F; Brehler, Randolf
2018-02-21
Aluminium is associated with disorders and is the commonly used vaccine adjuvant. Understanding the mechanisms of how Al is transported, metabolized or of its toxicity depends on the knowledge of Al-interactions with bioligands, i.e. Al-species. Al-speciation in serum is difficult because of low concentration and the risk of exogenous Al contamination. Furthermore, Al-measurements may be hampered according to various interferences. This study aims for developing quality controlled protocols for reliable Al- and Al-species determination and for investigating probable differences in Al (-speciation) after Al-containing subcutaneous immunotherapy (SIT). Sample donors were recruited either for the control group ("class-0", they never had been treated with SIT containing an Al-depot extract) or for the SIT-group ("class-1", they previously had been treated with SIT for insect venom allergy with an Al-depot extract). Blood was drawn for medical reasons and serum prepared. Additionally, some sample donors collected 24-h-urine. They had been informed (and they consented) about the scientific use of their samples. The study was approved by the ethic committee of the "Medical Association Westphalia-Lippe" and of the University of Münster, evaluating the study positively (No. 2013-667-f-S). We applied quality controlled sample preparation and interference-free Al detection by ICP sectorfield-mass spectrometry. Al-species were analysed using size-exclusion-chromatography-ICP-qMS. Al-concentrations or speciation in urine samples showed no differences between class-0 and class-1. Al-citrate was the main uric Al-species. In serum elevated Al-concentrations were found for both classes, with class-1 samples being significantly higher than class-0 (p = 0.041), but class-0 samples being approximately 10-fold too high compared to reference values from non-exposed persons. We identified gel-monovettes as contamination source. In contamination-free samples from HNO 3 -prewashed gel-free monovettes (n = 27) there was no difference in the serum Al concentration between the two patient groups (p = 0.669) INTERPRETATION: Thorough cleaning of sample preparation ware and use of gel-free monovettes is decisive for an accurate Al analysis in serum. Without these steps, wrong analysis and wrong conclusions are likely. We conclude that gel-monovettes are unsuitable for blood sampling with subsequent Al-analysis. Whether Al in serum is elevated after SIT treatment containing an Al-depot extract, or not, remains inconclusive as the non-contaminated sample size was small. Copyright © 2018 Elsevier GmbH. All rights reserved.
Jager, N G L; Rosing, H; Schellens, J H M; Linn, S C; Beijnen, J H
2014-02-01
A sensitive and selective HPLC-MS/MS assay was used to analyze steady-state serum concentrations of tamoxifen, N-desmethyltamoxifen (E)-endoxifen, (Z)-endoxifen, N-desmethyl-4'-hydroxytamoxifen, 4-hydroxytamoxifen, and 4'-hydroxytamoxifen to support therapeutic drug monitoring (TDM) in patients treated with tamoxifen according to standard of care. When the (Z)-endoxifen serum concentration was below the predefined therapeutic threshold concentration of 5.9 ng/mL, the clinician was advised to increase the tamoxifen dose and to collect another serum sample. Paired serum samples from patients at one dose level at different time points during the tamoxifen treatment were used to assess the intra-patient variability. A total of 251 serum samples were analyzed, obtained from 205 patients. Of these patients, 197 used 20 mg tamoxifen per day and 8 patients used 10 mg/day. There was wide variability in tamoxifen and metabolite concentrations within the dosing groups. The threshold concentration for (Z)-endoxifen was reached in one patient (12 %) in the 10 mg group, in 153 patients (78 %) in the 20 mg group, and in 26 (96 %) of the patients who received a dose increase to 30 or 40 mg/day. Dose increase from 20 to 30 or 40 mg per day resulted in a significant increase in the mean serum concentrations of all analytes (p < 0.001). The mean intra-patient variability was between 10 and 20 % for all analytes. These results support the suitability of TDM for optimizing the tamoxifen treatment. It is shown that tamoxifen dose is related to (Z)-endoxifen exposure and increasing this dose leads to a higher serum concentration of tamoxifen and its metabolites. The low intra-patient variability suggests that only one serum sample is needed for TDM, making this a relatively noninvasive way to optimize the patient's treatment.
Kiska, D L; Orkiszewski, D R; Howell, D; Gilligan, P H
1994-01-01
We evaluated the performance of CRYPTO-LEX (Trinity Laboratories, Inc., Raleigh, N. C.), a new mouse immunoglobulin M monoclonal antibody latex agglutination reagent which reacts with the capsular polysaccharide of the four serogroups of Cryptococcus neoformans. This test was compared with CALAS (Meridian Diagnostics, Cincinnati, Ohio) for the ability to detect cryptococcal antigen in serum and cerebrospinal fluid (CSF). A total of 580 clinical specimens (327 serum and 253 CSF samples), primarily from human immunodeficiency virus-infected patients, were tested in this study. Sixty-seven specimens (44 serum and 23 CSF samples) were positive for cryptococcal antigen with both tests, and 511 (282 serum and 229 CSF samples) were negative. The two latex reagents agreed for 326 of 327 serum specimens (44 positives and 282 negatives). One serum specimen with a titer of 1:2 was CALAS positive but CRYPTO-LEX negative. The titer correlation coefficient for the two tests was 0.884 when two highly discordant serum specimens were eliminated from analysis of the data. The two latex tests agreed for 252 of 253 CSF specimens (23 positives and 229 negatives). One specimen with a titer of 1:2 was positive with CALAS and negative by CRYPTO-LEX. The correlation coefficient of the two tests for CSF titers was 0.886. The sensitivity and specificity of CRYPTO-LEX were 97 and 100%, respectively, with a 99.6% correlation with CALAS. These data show that the performance of CRYPTO-LEX is comparable to that of CALAS for detection of cryptococcal antigen in serum and CSF. PMID:7814566
[Clinical evaluation of a novel HBsAg quantitative assay].
Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi
2007-07-01
The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.
Giménez-Lirola, Luis G; Mur, Lina; Rivera, Belen; Mogler, Mark; Sun, Yaxuan; Lizano, Sergio; Goodell, Christa; Harris, D L Hank; Rowland, Raymond R R; Gallardo, Carmina; Sánchez-Vizcaíno, José Manuel; Zimmerman, Jeff
2016-01-01
In the absence of effective vaccine(s), control of African swine fever caused by African swine fever virus (ASFV) must be based on early, efficient, cost-effective detection and strict control and elimination strategies. For this purpose, we developed an indirect ELISA capable of detecting ASFV antibodies in either serum or oral fluid specimens. The recombinant protein used in the ELISA was selected by comparing the early serum antibody response of ASFV-infected pigs (NHV-p68 isolate) to three major recombinant polypeptides (p30, p54, p72) using a multiplex fluorescent microbead-based immunoassay (FMIA). Non-hazardous (non-infectious) antibody-positive serum for use as plate positive controls and for the calculation of sample-to-positive (S:P) ratios was produced by inoculating pigs with a replicon particle (RP) vaccine expressing the ASFV p30 gene. The optimized ELISA detected anti-p30 antibodies in serum and/or oral fluid samples from pigs inoculated with ASFV under experimental conditions beginning 8 to 12 days post inoculation. Tests on serum (n = 200) and oral fluid (n = 200) field samples from an ASFV-free population demonstrated that the assay was highly diagnostically specific. The convenience and diagnostic utility of oral fluid sampling combined with the flexibility to test either serum or oral fluid on the same platform suggests that this assay will be highly useful under the conditions for which OIE recommends ASFV antibody surveillance, i.e., in ASFV-endemic areas and for the detection of infections with ASFV isolates of low virulence.
Suitability of selected free-gas and dissolved-gas sampling containers for carbon isotopic analysis.
Eby, P; Gibson, J J; Yi, Y
2015-07-15
Storage trials were conducted for 2 to 3 months using a hydrocarbon and carbon dioxide gas mixture with known carbon isotopic composition to simulate typical hold times for gas samples prior to isotopic analysis. A range of containers (both pierced and unpierced) was periodically sampled to test for δ(13)C isotopic fractionation. Seventeen containers were tested for free-gas storage (20°C, 1 atm pressure) and 7 containers were tested for dissolved-gas storage, the latter prepared by bubbling free gas through tap water until saturated (20°C, 1 atm) and then preserved to avoid biological activity by acidifying to pH 2 with phosphoric acid and stored in the dark at 5°C. Samples were extracted using valves or by piercing septa, and then introduced into an isotope ratio mass spectrometer for compound-specific δ(13)C measurements. For free gas, stainless steel canisters and crimp-top glass serum bottles with butyl septa were most effective at preventing isotopic fractionation (pierced and unpierced), whereas silicone and PTFE-butyl septa allowed significant isotopic fractionation. FlexFoil and Tedlar bags were found to be effective only for storage of up to 1 month. For dissolved gas, crimp-top glass serum bottles with butyl septa were again effective, whereas silicone and PTFE-butyl were not. FlexFoil bags were reliable for up to 2 months. Our results suggest a range of preferred containers as well as several that did not perform very well for isotopic analysis. Overall, the results help establish better QA/QC procedures to avoid isotopic fractionation when storing environmental gas samples. Recommended containers for air transportation include steel canisters and glass serum bottles with butyl septa (pierced and unpierced). Copyright © 2015 John Wiley & Sons, Ltd.
Long-duration space flight and bed rest effects on testosterone and other steroids.
Smith, Scott M; Heer, Martina; Wang, Zuwei; Huntoon, Carolyn L; Zwart, Sara R
2012-01-01
Limited data suggest that testosterone is decreased during space flight, which could contribute to bone and muscle loss. The main objective was to assess testosterone and hormone status in long- and short-duration space flight and bed rest environments and to determine relationships with other physiological systems, including bone and muscle. Blood and urine samples were collected before, during, and after long-duration space flight. Samples were also collected before and after 12- to 14-d missions and from participants in 30- to 90-d bed rest studies. Space flight studies were conducted on the International Space Station and before and after Space Shuttle missions. Bed rest studies were conducted in a clinical research center setting. Data from Skylab missions are also presented. All of the participants were male, and they included 15 long-duration and nine short-duration mission crew members and 30 bed rest subjects. Serum total, free, and bioavailable testosterone were measured along with serum and urinary cortisol, serum dehydroepiandrosterone, dehydroepiandrosterone sulfate, and SHBG. Total, free, and bioavailable testosterone was not changed during long-duration space flight but were decreased (P < 0.01) on landing day after these flights and after short-duration space flight. There were no changes in other hormones measured. Testosterone concentrations dropped before and soon after bed rest, but bed rest itself had no effect on testosterone. There was no evidence for decrements in testosterone during long-duration space flight or bed rest.
Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning
2013-03-01
Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.
Harrington, James M; Young, Daniel J; Essader, Amal S; Sumner, Susan J; Levine, Keith E
2014-07-01
Minerals are inorganic compounds that are essential to the support of a variety of biological functions. Understanding the range and variability of the content of these minerals in biological samples can provide insight into the relationships between mineral content and the health of individuals. In particular, abnormal mineral content may serve as an indicator of illness. The development of robust, reliable analytical methods for the determination of the mineral content of biological samples is essential to developing biological models for understanding the relationship between minerals and illnesses. This paper describes a method for the analysis of the mineral content of small volumes of serum and whole blood samples from healthy individuals. Interday and intraday precision for the mineral content of the blood (250 μL) and serum (250 μL) samples was measured for eight essential minerals--sodium (Na), calcium (Ca), magnesium (Mg), potassium (K), iron (Fe), zinc (Zn), copper (Cu), and selenium (Se)--by plasma spectrometric methods and ranged from 0.635 to 10.1% relative standard deviation (RSD) for serum and 0.348-5.98% for whole blood. A comparison of the determined ranges for ten serum samples and six whole blood samples provided good agreement with literature reference ranges. The results demonstrate that the digestion and analysis methods can be used to reliably measure the content of these minerals and potentially of other minerals.
[Presence of west Nile virus in northeast Mexico].
Fernández-Salas, Ildefonso; de Lourdes Garza-Rodríguez, María; Beaty, Barry J; Jiménez, Javier Ramos; Rivas-Estilla, Ana María
2007-01-01
To investigate the presence of WNV in birds, horses and humans in northeast Mexico. Serum samples from 33 birds, 24 horses and 237 humans were screened by ELISA for Anti-WNV antibodies. Human serum samples were also screened for WNV RNA using an RT-PCR assay. Positive sera were found in three birds and 15 horses. Forty percent of the human serum samples were positive for IgG antibodies and 0% for IgM antibodies and viral RNA. The results of this study show that WNV is present in northeast Mexico and it is a new emergent infectious agent that represents a challenge for research and prevention programs in Mexico.
Cotinine Concentration in Serum Correlates with Tobacco Smoke-Induced Emphysema in Mice
NASA Astrophysics Data System (ADS)
Xu, Xin; Su, Yunchao; Fan, Z. Hugh
2014-01-01
Secondhand smoke (SHS) has been associated with a variety of adverse health outcomes in nonsmokers, including emphysema (a chronic obstructive pulmonary disease). One way to detect SHS exposure is to measure the concentration of cotinine, the primary metabolite of nicotine, in bodily fluids. We have developed a method for cotinine analysis by combining micellar electrokinetic chromatography with enrichment techniques. We employed the method to measure cotinine concentrations in serum samples of mice exposed to tobacco smoke for 12 or 24 weeks and found that it was 3.1-fold or 4.8-fold higher than those exposed to room air for the same period. Further, we investigated the morphological changes in lungs of mice and observed tobacco smoke induced emphysema. Our results indicate that the method can be used to measure cotinine and there is an association between the serum cotinine concentration and tobacco smoke-induced emphysema in mice.
Lampon, Natalia; Pampin, Fernando; Tutor, J Carlos
2012-01-01
Although the possible interference of digoxin-like immunoreactive substances (DLIS) on the Architect iDigoxin chemiluminiscent microparticle immunoassay (CMIA) has been emphasized by the manufacturer, a specific study about this subject has still not been carried out. Apparent serum digoxin concentrations were determined using the Architect iDigoxin CMIA from Abbott Laboratories in digoxin-free pregnant women (n = 50), and patients with liver disease (n = 50), renal insufficiency (n = 50), kidney (n = 25) or liver (n = 25) transplant, and critical illness (n = 50). In all of the patients included in this study, apparent serum digoxin concentrations were lower than the correspondent quantification limit (< 0.30 microg/L). The Architect iDigoxin CMIA assay would be relatively free from endogenous DLIS positive interferences.
Sert, Tuba; Kırzıoğlu, F Yeşim; Fentoğlu, Ozlem; Aylak, Firdevs; Mungan, Tamer
2011-12-01
The aim of this study is the evaluation of levels of serum interleukin (IL)-1β, IL-6, IL-10, tumor necrosis factor (TNF)-α, vascular endothelial growth factor (VEGF), placental growth factor (PIGF), and soluble VEGF receptor (sVEGFR)-1 and -2 in the association between periodontal disease and adverse pregnancy outcomes. One hundred and nine mothers, who recently gave birth, and 51 women who were not recently pregnant, aged 18 to 35 years, were included in this study. The mothers were classified as term birth, preterm birth (PTB), and preterm low birth weight (PLBW) in respect to their gestational age and baby's birth weight. The birth mothers were grouped as having gingivitis or periodontitis. The non-pregnant group also included periodontally healthy patients. Venous blood samples were collected to evaluate serum IL-1β, IL-6, IL-10, TNF-α, VEGF, PIGF, and sVEGFR-1 and -2 levels. Mother's weight, education, and income level were significantly associated with pregnancy outcomes. Serum levels of IL-1β, TNF-α, IL-6, VEGF, and sVEGFR-1 and -2 showed an increase in significance when related to pregnancy. Whereas in the PLBW group IL-1β, VEGF, and sVEGFR-2 levels were increased, in the PTB group sVEGFR-1 levels were increased. Additionally, the patients in the PLBW group with periodontitis had higher serum levels of IL-1β, VEGF, sVEGFR-2, and IL-1β/IL-10. The serum levels of IL-1β, VEGF, and sVEGFR-1 and -2 may have a potential effect on the mechanism of the association between periodontal disease and adverse pregnancy outcomes.
Maternal serum fatty acid binding protein 4 (FABP4) and the development of preeclampsia.
Scifres, Christina M; Catov, Janet M; Simhan, Hyagriv
2012-03-01
Serum fatty acid binding protein 4 (FABP4) is associated with components of the metabolic syndrome in nonpregnant individuals, including dyslipidemia and insulin resistance. Preeclampsia shares many features with the metabolic syndrome, but the relationship between early pregnancy serum FABP4 levels and the development of preeclampsia is unknown. The aim of the study was to test the hypothesis that FABP4 is elevated in women who develop preeclampsia before the onset of disease. This was a nested case-control study within a larger prospective cohort of healthy women with singleton gestations. Cases included 22 women who developed preeclampsia, and a random sample of 72 unmatched controls delivered without preeclampsia was identified. Maternal serum FABP4 was measured at less than 13 wk gestation and 24-28 wk gestation, which was before the onset of preeclampsia in all patients. The main outcome measure was preeclampsia (new-onset gestational hypertension and proteinuria for the first time after 20 wk gestation). Maternal serum FABP4 concentrations were higher in women who ultimately developed preeclampsia both at 8-13 wk (20.4±12.3 vs. 10.1±4.7 ng/ml; P<0.01) and at 24-28 wk (20.7±11.7 vs. 9.9±4.5 ng/ml; P<0.01). After controlling for first trimester body mass index, systolic blood pressure, and nulliparity, FABP4 was associated with the development of preeclampsia (adjusted odds ratio, 1.2; 95% confidence interval, 1.1-1.3; P<0.01). Maternal serum FABP4 levels are elevated before the clinical onset of preeclampsia, and this increase occurs independently of maternal body mass index.
Cai, Jie; Wu, Meng; Ren, Jie; Du, Yali; Long, Zhangbiao; Li, Guoxun; Han, Bing; Yang, Lichen
2017-05-02
Our aim was to evaluate the cut-off value and efficiency of using reticulocyte hemoglobin content as a marker to diagnose iron deficiency anemia in Chinese adults. 140 adults who needed bone marrow aspiration for diagnosis at the hematology department of the Peking Union Medical College Hospital were enrolled according to the inclusive and exclusive criteria. Venous blood samples were collected to detect complete blood count, including hemoglobin, reticulocyte hemoglobin content, hematocrit, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, free erythrocyte protoporphyrin; iron indexes of serum ferritin, serum transferrin receptor, and unsaturated iron-binding capacity; and inflammation markers of C-reactive protein and α-acid glycoprotein. Bone marrow samples were obtained for the bone marrow iron staining, which was used as the standard for the evaluation of iron status in this study. Subjects were divided into three groups according to hemoglobin levels and bone marrow iron staining results: the IDA (iron deficiency anemia) group, the NIDA (non-iron deficiency anemia) group, and the control group. The differences of the above-mentioned indexes were compared among the three groups and the effect of inflammation was also considered. The cut-off value of reticulocyte hemoglobin content was determined by receiver operation curves. The IDA group ( n = 56) had significantly lower reticulocyte hemoglobin content, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, and serum ferritin; and higher free erythrocyte protoporphyrin, unsaturated iron-binding capacity, and serum transferrin receptor ( p < 0.05) compared with the NIDA group ( n = 38) and control group ( n = 46). Hematocrit, serum ferritin, and unsaturated iron-binding capacity were significantly affected by inflammation while reticulocyte hemoglobin content and other parameters were not. The cut-off value of reticulocyte hemoglobin content for diagnosing iron deficiency anemia was 27.2 pg, with a sensitivity of 87.5% and a specificity of 92.9%. The cut-off values for mean cellular volume, serum ferritin, and serum transferrin receptor were 76.6, 12.9, and 4.89 mg/L, respectively. Reticulocyte hemoglobin content had the largest area under the curve of 0.929, while those for mean cellular volume, serum ferritin, serum transferrin receptor were 0.922, 0.887, and 0.900, respectively. Reticulocyte hemoglobin content has a high sensitivity and specificity in the diagnosis of iron deficiency anemia, and its comprehensive diagnostic efficacy is better than other traditional indicators-such as serum ferritin and serum transferrin receptor.
Gümüş, Pınar; Nizam, Nejat; Nalbantsoy, Ayşe; Özçaka, Özgün; Buduneli, Nurcan
This cross-sectional study aims to evaluate saliva, serum levels of interleukin-21 (IL-21), IL-33, and prostaglandin E2 (PGE2) in patients with generalised chronic periodontitis or aggressive periodontitis. Before initiation of any periodontal treatment, saliva and serum samples were collected and clinical periodontal measurements were recorded from 94 participants (25 aggressive periodontitis patients, 25 chronic periodontitis patients, 44 periodontally healthy individuals). IL-21, IL-33 and PGE2 levels in serum and saliva samples were determined by ELISA. Data were tested statistically using Kruskal-Wallis, Mann-Whitney U-, and Spearman-rho rank tests. Saliva IL-33 levels were statistically significantly higher in the chronic than the aggressive group (p < 0.05). Serum IL-33, saliva and serum IL-21 and PGE2 levels were similar in the two periodontitis groups. Saliva IL-33 levels correlated with age in the chronic periodontitis group (p < 0.05). Statistically significant positive correlations were found between serum, saliva PGE2 levels and plaque index (p < 0.05). IL-33 and IL-21 levels in serum samples positively correlated in the periodontitis groups (p < 0.05). IL-21 and PGE2 analysis did not exhibit discriminating data between generalised chronic and aggressive periodontitis, but the present findings support the role of these cytokines in periodontitis. Statistically significantly higher saliva IL-33 levels in the chronic periodontitis group warrant further research.
Use of Paired Serum Samples for Serodiagnosis of Typhoid Fever
House, Deborah; Chinh, Nguyen T.; Diep, To S.; Parry, Christopher M.; Wain, John; Dougan, Gordon; White, Nicholas J.; Hien, Tran Tinh; Farrar, Jeremy J.
2005-01-01
Using an enzyme-linked immunosorbent assay we demonstrate that, in adult patients with typhoid fever, the sensitivity of a serological test based on the detection of anti-lipopolysaccharide immunoglobulin G is increased when used with paired serum samples taken 1 week apart. PMID:16145168
Nosocomial Outbreak of Parechovirus 3 Infection among Newborns, Austria, 2014.
Strenger, Volker; Diedrich, Sabine; Boettcher, Sindy; Richter, Susanne; Maritschnegg, Peter; Gangl, Dietmar; Fuchs, Simone; Grangl, Gernot; Resch, Bernhard; Urlesberger, Berndt
2016-09-01
In 2014, sepsis-like illness affected 9 full-term newborns in 1 hospital in Austria. Although results of initial microbiological testing were negative, electron microscopy identified picornavirus. Archived serum samples and feces obtained after discharge were positive by PCR for human parechovirus 3. This infection should be included in differential diagnoses of sepsis-like illness in newborns.
Serum markers for type II diabetes mellitus
Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Polpitiya, Ashoka D; Camp, II, David G; Smith, Richard D
2014-03-18
A method for identifying persons with increased risk of developing type 2 diabetes mellitus utilizing selected biomarkers described hereafter either alone or in combination. The present invention allows for broad based, reliable, screening of large population bases and provides other advantages, including the formulation of effective strategies for characterizing, archiving, and contrasting data from multiple sample types under varying conditions.
Liang, Fang Ting; Granstrom, David E.; Zhao, Xiao Min; Timoney, John F.
1998-01-01
Sarcocystis neurona is the etiologic agent of equine protozoal myeloencephalitis (EPM). Based on an analysis of 25,000 equine serum and cerebrospinal fluid (CSF) samples, including samples from horses with neurologic signs typical of EPM or with histologically or parasitologically confirmed EPM, four major immunoblot band patterns have been identified. Twenty-three serum and CSF samples representing each of the four immunoblot patterns were selected from 220 samples from horses with neurologic signs resembling EPM and examined for inhibitory effects on the infectivity of S. neurona by an in vitro neutralization assay. A high correlation between immunoblot band pattern and neutralizing activity was detected. Two proteins, Sn14 and Sn16 (14 and 16 kDa, respectively), appeared to be important for in vitro infection. A combination of the results of surface protein labeling, immunoprecipitation, Western blotting, and trypsin digestion suggests that these molecules are surface proteins and may be useful components of a vaccine against S. neurona infection. Although S. neurona is an obligate intracellular parasite, it is potentially a target for specific antibodies which may lyse merozoites via complement or inhibit their attachment and penetration to host cells. PMID:9573058
Seroprevalence of Chikungunya in Southern Odisha
Mohanty, Indrani; Dash, Muktikesh; Sahu, Susmita; Narasimham, M.V.; Panda, Pritilata; Padhi, Sanghamitra
2013-01-01
Background: The emergence of chikungunya (CHIK) infection was observed in Odisha, India in 2006. Thereafter many cases with symptoms suggestive of CHIK were reported from different districts of Southern-Odisha. This study was aimed to know the seroprevalence, clinical presentations and seasonal trends of CHIK infection in this region. Materials and Methods: This study was conducted in a tertiary hospital of this region. Serum samples received in the Department of Microbiology from various districts of Southern-Odisha from April 2011 to March 2012 were included in the study. The samples were tested for CHIK and dengue Immunoglobin M (IgM) antibodies by enzyme-linked immunosorbent assay and malaria parasite by immunochromatographic test (ICT) method. Results: Out of the 678 serum samples tested, 174 were positive for CHIK, 15 for dengue and two samples were positive for both CHIK and dengue IgM antibodies. The most affected age group was 16-45 years. Females were more affected than males. Conclusion: The seroprevalence of CHIK among the suspected cases was 25.7%. Co-infection with CHIK and dengue was found to be 1.15%. The infection had spread to new areas during this outbreak. PMID:24479040
Alemtuzumab: validation of a sensitive and simple enzyme-linked immunosorbent assay.
Jilani, Iman; Keating, Michael; Giles, Francis J; O'Brien, Susan; Kantarjian, Hagop M; Albitar, Maher
2004-12-01
Alemtuzumab (MabCampath) is a humanized rat monoclonal antibody that targets the CD52 antigen. It has been approved for the treatment of patients with resistant chronic lymphocytic leukaemia (CLL). Measuring plasma/serum levels of alemtuzumab is important for optimizing the dosing and scheduling of therapy; however, current assays in serum or plasma, based on the capture of alemtuzumab using CD52, are complicated and difficult to adapt for high throughput testing. We developed a simple sandwich enzyme-linked immunosorbent assay (ELISA) to measure alemtuzumab that takes advantage of the remaining rat sequence in alemtuzumab. Using specific anti-rat immunoglobulin (Ig) antibodies (absorbed against human Ig), alemtuzumab levels were measured in the serum and plasma of patients treated with alemtuzumab. Levels were similar between plasma and serum samples, in fresh samples and samples stored at 4 degrees C for 24 h, but were significantly lower in samples stored at room temperature for 24h. The assay was successfully used to determine serum alemtuzumab pre- and post-treatment. This assay is simple and adaptable for high throughput testing, with a limit of detection of 0.05 microg/ml and a coefficient of variation of +/-12.5%. No false positivity was observed in >200 samples tested. This validated assay should help optimize the dosing and scheduling of alemtuzumab therapy. The underlying principles are also applicable to the measurement of other humanized antibodies using an appropriate anti-Ig.
Curry, Patricia S; Ribble, Carl; Sears, William C; Hutchins, Wendy; Orsel, Karin; Godson, Dale; Lindsay, Robbin; Dibernardo, Antonia; Kutz, Susan J
2014-04-01
We compared Nobuto filter paper (FP) whole-blood samples to serum for detecting antibodies to seven pathogens in reindeer (Rangifer tarandus tarandus). Serum and FP samples were collected from captive reindeer in 2008-2009. Sample pairs (serum and FP eluates) were assayed in duplicate at diagnostic laboratories with the use of competitive enzyme-linked immunosorbent assays (cELISAs) for Neospora caninum and West Nile virus (WNV); indirect ELISA (iELISAs) for bovine herpesvirus type 1 (BHV-1), parainfluenza virus type 3 (PI-3), and bovine respiratory syncytial virus (BRSV); and virus neutralization (VN) for bovine viral diarrhea virus (BVDV) types I and II. Assay thresholds were evidence-based values employed by each laboratory. Comparable performance to serum was defined as FP sensitivity and specificity ≥ 80%. Filter-paper specificity estimates ranged from 92% in the cELISAs for N. caninum and WNV to 98% in the iELISAs for PI-3 and BRSV. Sensitivity was >85% for five tests (most ≥ 95%) but was insufficient (71-82%) for the PI-3 and BRSV iELISAs. Lowering the threshold for FP samples in these two ELISAs raised sensitivity to ≥ 87% and reduced specificity slightly (≥ 90% in three of the four test runs). Sample size limited the precision of some performance estimates. Based on the criteria of sensitivity and specificity ≥ 80%, and using adjusted FP thresholds for PI-3 and BRSV, FP sensitivity and specificity were comparable to serum in all seven assays. A potential limitation of FP is reduced sensitivity in tests that require undiluted serum (i.e., N. caninum cELISA and BVDV VNs). Possible toxicity to the assay cell layer in VN requires investigation. Results suggested that cELISA is superior to iELISA for detecting antibodies in FP samples from reindeer and other Rangifer tarandus subspecies. Our findings expand the potential utility of FP sampling from wildlife.
Ambreen, Fareeha; Ismail, Muhammad; Qureshi, Irfan Zia
2015-01-01
To study the association of serum levels of inflammatory mediators and angiogenic factors with genetic polymorphism in Pakistani age-related macular degeneration (AMD) patients. This was a cross-sectional and case-control study that included 90 AMD patients diagnosed through slit-lamp examination, fundoscopy, and ocular coherence tomography. For reference and comparison purposes, 100 healthy age-matched subjects (controls) were also recruited. IL-6, IL-8, VEGF, and CRP levels were estimated in the serum samples of patients and control subjects. Using restriction fragment length polymorphism, single nucleotide polymorphisms were studied in IL-6 (rs1800795, rs1800796, rs1800797), IL-8 (rs4073, rs2227306, rs2227543), VEGF (rs3025039, rs699947), and CRP genes (rs1205, rs1130864). Since the data were obtained from a sample population, the Box-Cox transformation algorithm was applied to reduce heterogeneity of error. Multivariate analyses of variance (M-ANOVA) were applied on the transformed data to investigate the association of serum levels of IL-6, IL-8, VEGF, and CRP with AMD. Genotype and allele frequencies were compared through χ(2) tests applying Hardy-Weinberg equilibrium. The serum concentrations of IL-6 and IL-8, VEGF, and CRP between homozygotes and heterozygotes were compared through one-way ANOVA. Significance level was p<0.05. Compared to control subjects, serum IL-6 (p<0.0001), IL-8 (p<0.0001), VEGF (p<0.0001), and CRP (p<0.0001) levels were significantly elevated in the AMD patients. For rs1800795, patients with the GG genotype showed significantly raised levels of IL-6 compared to those with GC and CC genotypes (p<0.0001). Serum IL-8 levels were significantly higher in patients with the GG genotype compared to the GC and CC genotypes for the single nucleotide polymorphism (SNP) rs2227543 (p<0.002). Similarly, significantly higher VEGF levels were detected for genotype TT for rs3025039 SNP (p<0.038). However, no significant alteration in serum CRP levels was detected in hetero- or homozygotes for rs1205 and rs1130864 SNPs. Serum IL-6, IL-8, and VEGF levels are substantially increased in AMD, and the levels coincide with polymorphism in the respective gene. No such relationship appears to exist with regard to SNPs of CRP.
Shafinaz, I S; Moy, F M
2016-03-07
Vitamin D deficiency is highly prevalent in both temperate as well as tropical countries. Obesity is one of the factors contributing to vitamin D deficiency. As our country has a high prevalence of overweight and obesity, we aimed to study serum 25-hydroxyvitamin D (25(OH)D) level and its association with adiposity using various adiposity indicators; and to study other risk factors that affect serum 25(OH)D level among multi-ethnic adults in Kuala Lumpur, Malaysia. This was a cross sectional study conducted with a multistage sampling. All permanent teachers working in government secondary schools in Kuala Lumpur were invited for the study. The data collection included serum 25(OH)D, Parathyroid Hormone (PTH), body fat percentage, waist circumference, body mass index (BMI) and blood pressure. Demographic characteristics, sun avoidance, sun exposure and physical activity were enquired from the participants using a self-administered questionnaire. The data was analyzed using a complex sample analysis. A total of 858 participants were recruited. Majority of them were Malays, females and had tertiary education. The overall prevalence of vitamin D deficiency (<20 ng/ml) was 67.4 %. Indian participants (80.9 %) had the highest proportion of vitamin D deficiency, followed by Malays (75.6 %), others (44.9 %) and Chinese (25.1 %). There was a significant negative association between serum 25(OH)D level with BMI (β = -0.23) and body fat percentage (β = -0.14). In the multivariate linear regression analysis, Malays, Indians and females (p < 0.001); higher BMI and larger waist circumference (p < 0.05) were significantly associated with lower serum 25(OH)D level. The full model explained 32.8 % of the variation between participants in the serum 25(OH)D level. The two most influential factors affecting serum 25(OH)D level were ethnicity and gender. The prevalence of vitamin D deficiency among our participants was high. Adiposity was associated with serum 25(OH)D level. Skin pigmentation and gender based behaviours were more dominant in contributing to serum 25(OH)D level. Health education should be targeted in weight management, gender based behaviours on sun exposure, as skin pigmentation is non-modifiable.
Sochorová, Lenka; Hanzlíková, Lenka; Černá, Milena; Drgáčová, Anna; Fialová, Alena; Švarcová, Andrea; Gramblička, Tomáš; Pulkrabová, Jana
2017-03-01
Persistent organic pollutants, such as perfluorinated alkylated substances (PFASs) and brominated flame retardants (BFRs) are widespread in the environment and most of them are bioaccumulated in wildlife and humans. The present study is the first investigation to reveal the PFAS and BFR levels of serum samples in the adult population of the Czech Republic. Altogether, 300 serum samples from blood donors in four cities were examined. In all samples 19 PFASs and 33 BFRs, including some of their metabolites, were targeted. The analyses were performed using ultra high performance liquid chromatography coupled with tandem mass spectrometry or gas chromatography with mass spectrometry (according to the type of analyte). PFASs, with the carbon chain length C6 and higher, dominated in all samples. Perfluorooctanesulfonate (PFOS; median: 2.43ng/mL), perfluorooctanoic acid (PFOA; median: 0.756ng/mL), perfluorodecanoic acid (PFDA; median: 0.145ng/mL) and perfluorohexanesulfonate (PFHxS; median: 0.184ng/mL) were detected in 100% of samples. Perfluorononanoic acid (PFNA; median: 0.325ng/mL) and perfluoroundecanoic acid (PFUdA; median: 0.058ng/mL) in 99.7% and 96.0% of samples, respectively. We observed statistically significant associations (p<0.05) between selected PFAS concentrations and the locality, gender, age of donors and education level. None of the BFRs was detected above the LOQ in more than 9% of the samples. The most frequently detected representatives of this group were congeners of polybrominated diphenyl ethers, namely BDE-47 (in 8.7%; range: 0.496-5.44ng/g lipid weight (l.w.)), BDE-99 (in 6.0%; range: 0.706-9.46ng/g l.w.), BDE-153 (in 7.3%; range: 0.736-6.44ng/g l.w.) and BDE-209 (in 7.0%; range: 13.7-2693ng/g l.w.). Copyright © 2016 Elsevier GmbH. All rights reserved.
Correlation Between Iron and alpha and pi Glutathione-S-Transferase Levels in Humans
2012-09-01
assays were performed as described in the Biotrin High Sensitivity Alpha GST EIA kit protocol. First, serum samples were diluted 1:10 with wash solution...immunosorbent assays were performed as described in the Biotrin Pi GST EIA kit protocol. First, plasma samples were diluted 1:5 with sample diluent...immunosorbent assays were performed as described in the AssayMax Human Transferrin ELISA kit protocol. First, serum samples were diluted 1:2000 with MIX
Ozone Exposure Increases Circulating Stress Hormones and Lipid Metabolites in Humans
Miller, Desinia B.; Ghio, Andrew J.; Karoly, Edward D.; Bell, Lauren N.; Snow, Samantha J.; Madden, Michael C.; Soukup, Joleen; Cascio, Wayne E.; Gilmour, M. Ian
2016-01-01
Rationale: Air pollution has been associated with increased prevalence of type 2 diabetes; however, the mechanisms remain unknown. We have shown that acute ozone exposure in rats induces release of stress hormones, hyperglycemia, leptinemia, and glucose intolerance that are associated with global changes in peripheral glucose, lipid, and amino acid metabolism. Objectives: To examine ozone-induced metabolic derangement in humans using serum metabolomic assessment, establish human-to-rodent coherence, and identify novel nonprotein biomarkers. Methods: Serum samples were obtained from a crossover clinical study that included two clinic visits (n = 24 each) where each subject was blindly exposed in the morning to either filtered air or 0.3 parts per million ozone for 2 hours during 15-minute on-off exercise. Serum samples collected within 1 hour after exposure were assessed for changes in metabolites using a metabolomic approach. Measurements and Main Results: Metabolomic analysis revealed that ozone exposure markedly increased serum cortisol and corticosterone together with increases in monoacylglycerol, glycerol, and medium- and long-chain free fatty acids, reflective of lipid mobilization and catabolism. Additionally, ozone exposure increased serum lysolipids, potentially originating from membrane lipid breakdown. Ozone exposure also increased circulating mitochondrial β-oxidation–derived metabolites, such as acylcarnitines, together with increases in the ketone body 3-hydroxybutyrate. These changes suggested saturation of β-oxidation by ozone in exercising humans. Conclusions: As in rodents, acute ozone exposure increased stress hormones and globally altered peripheral lipid metabolism in humans, likely through activation of a neurohormonally mediated stress response pathway. The metabolomic assessment revealed new biomarkers and allowed for establishment of rodent-to-human coherence. Clinical trial registered with www.clinicaltrials.gov (NCT 01492517). PMID:26745856
Alkerwi, Ala'a; Sauvageot, Nicolas; Crichton, Georgina E; Elias, Merrill F; Stranges, Saverio
2016-05-01
This study examined the association of chocolate consumption with insulin resistance and serum liver enzymes in a national sample of adults in Luxembourg. A random sample of 1153 individuals, aged 18-69 years, was recruited to participate in the cross-sectional Observation of Cardiovascular Risk Factors in Luxembourg study. Chocolate consumption (g/d) was obtained from a semi-quantitative FFQ. Blood glucose and insulin levels were used for the homoeostasis model assessment of insulin resistance (HOMA-IR). Hepatic biomarkers such as serum γ-glutamyl-transpeptidase (γ-GT), serum aspartate transaminase and serum alanine transaminase (ALT) (mg/l) were assessed using standard laboratory assays. Chocolate consumers (81·8 %) were more likely to be younger, physically active, affluent people with higher education levels and fewer chronic co-morbidities. After excluding subjects taking antidiabetic medications, higher chocolate consumption was associated with lower HOMA-IR (β=-0·16, P=0·004), serum insulin levels (β=-0·16, P=0·003) and γ-GT (β=-0·12, P=0·009) and ALT (β=-0·09, P=0·004), after adjustment for age, sex, education, lifestyle and dietary confounding factors, including intakes of fruits and vegetables, alcohol, polyphenol-rich coffee and tea. This study reports an independent inverse relationship between daily chocolate consumption and levels of insulin, HOMA-IR and liver enzymes in adults, suggesting that chocolate consumption may improve liver enzymes and protect against insulin resistance, a well-established risk factor for cardiometabolic disorders. Further observational prospective research and well-designed randomised-controlled studies are needed to confirm this cross-sectional relationship and to comprehend the role and mechanisms that different types of chocolate may play in insulin resistance and cardiometabolic disorders.
Tharwat, Mohamed; Al-Sobayil, Fahd; El-Sayed, Mehana
2013-12-01
This study was designed to establish serum cardiac troponin I (cTnI) concentrations in healthy newborn goat kids and in those with cardiac nutritional muscular dystrophy (NMD). Thirty-five single full-term newborn goat kids (20 males and 15 females; age: 6.1 ± 3.5 h; weight 3.4 ± 0.68 kg), together with their respective mothers (Group 1; G1) were enrolled consecutively. Thirty-one goat kids (age: 9.5 ± 4.3 days) with NMD, together with 20 control goat kids (age: 7.8 ± 4.3 days) were also included in this study (Group 2; G2). Blood samples were collected from G1 within 12 h of birth and from G2 on admission. Serum samples were collected and analysed for cTnI. In G1, the mean serum concentration of cTnI in goat kids was 0.290 ± 0.37 ng/mL, with no statistically significant difference between male and female kids (P = 0.61). The mean cTnI concentration in the does was 0.017 ± 0.04, ng/mL. Serum values of cTnI in the goat kids and in their respective mothers differed significantly (P = 0.0001). In G2, the mean cTnI concentration was 0.02 ± 0.05 ng/mL in the control and 11.18 ± 20.07 ng/mL in the diseased goat kids, with a statistically significant difference between diseased and control goat kids (P = 0.017). Serum concentrations of cTnI are higher in goat kids than in their respective mothers. In conclusion, the cTnI assay appears to be a sensitive and specific marker for myocardial injury in goat kids.
Postmenopausal estrogen and progestin effects on the serum proteome
2009-01-01
Background Women's Health Initiative randomized trials of postmenopausal hormone therapy reported intervention effects on several clinical outcomes, with some important differences between estrogen alone and estrogen plus progestin. The biologic mechanisms underlying these effects, and these differences, have yet to be fully elucidated. Methods Baseline serum samples were compared with samples drawn 1 year later for 50 women assigned to active hormone therapy in both the estrogen-plus-progestin and estrogen-alone randomized trials, by applying an in-depth proteomic discovery platform to serum pools from 10 women per pool. Results In total, 378 proteins were quantified in two or more of the 10 pooled serum comparisons, by using strict identification criteria. Of these, 169 (44.7%) showed evidence (nominal P < 0.05) of change in concentration between baseline and 1 year for one or both of estrogen-plus-progestin and estrogen-alone groups. Quantitative changes were highly correlated between the two hormone-therapy preparations. A total of 98 proteins had false discovery rates < 0.05 for change with estrogen plus progestin, compared with 94 for estrogen alone. Of these, 84 had false discovery rates <0.05 for both preparations. The observed changes included multiple proteins relevant to coagulation, inflammation, immune response, metabolism, cell adhesion, growth factors, and osteogenesis. Evidence of differential changes also was noted between the hormone preparations, with the strongest evidence in growth factor and inflammation pathways. Conclusions Serum proteomic analyses yielded a large number of proteins similarly affected by estrogen plus progestin and by estrogen alone and identified some proteins and pathways that appear to be differentially affected between the two hormone preparations; this may explain their distinct clinical effects. PMID:20034393
Serosurvey of Crimean-Congo Hemorrhagic Fever Virus in Cattle, Mali, West Africa.
Maiga, Ousmane; Sas, Miriam Andrada; Rosenke, Kyle; Kamissoko, Badian; Mertens, Marc; Sogoba, Nafomon; Traore, Abdallah; Sangare, Modibo; Niang, Mamadou; Schwan, Tom G; Maiga, Hamidou Moussa; Traore, Sekou F; Feldmann, Heinz; Safronetz, David; Groschup, Martin H
2017-06-01
AbstractCrimean-Congo hemorrhagic fever is a tick-borne disease caused by the arbovirus Crimean-Congo hemorrhagic fever virus (CCHFV, family Bunyaviridae, genus Nairovirus ). CCHFV can cause a severe hemorrhagic fever with high-case fatality rates in humans. CCHFV has a wide geographic range and has been described in around 30 countries in the Middle East, Asia, Europe, and Africa including Mali and neighboring countries. To date, little is known about the prevalence rates of CCHFV in Mali. Here, using banked bovine serum samples from across the country, we describe the results of a seroepidemiological study for CCHFV aimed at identifying regions of circulation in Mali. In total, 1,074 serum samples were tested by a modified in-house CCHFV-IgG-enzyme-linked immunosorbent assay (ELISA) with confirmatory testing by commercial ELISA and immunofluorescence assay. Overall, 66% of samples tested were positive for CCHFV-specific IgG antibodies. Regional seroprevalence rates ranged from 15% to 95% and seemed to correlate with cattle density. Our results demonstrate that CCHFV prevalence is high in many regions in Mali and suggest that CCHFV surveillance should be established.
Amoeba-Resisting Bacteria and Ventilator-Associated Pneumonia
La Scola, Bernard; Boyadjiev, Ioanna; Greub, Gilbert; Khamis, Atieh; Martin, Claude
2003-01-01
To evaluate the role of amoeba-associated bacteria as agents of ventilator-associated pneumonia (VAP), we tested the water from an intensive care unit (ICU) every week for 6 months for such bacteria isolates; serum samples and bronchoalveolar lavage samples (BAL) were also obtained from 30 ICU patients. BAL samples were examined for amoeba-associated bacteria DNA by suicide-polymerase chain reaction, and serum samples were tested against ICU amoeba-associated bacteria. A total of 310 amoeba-associated bacteria from10 species were isolated. Twelve of 30 serum samples seroconverted to one amoeba-associated bacterium isolated in the ICU, mainly Legionella anisa and Bosea massiliensis, the most common isolates from water (p=0.021). Amoeba-associated bacteria DNA was detected in BAL samples from two patients whose samples later seroconverted. Seroconversion was significantly associated with VAP and systemic inflammatory response syndrome, especially in patients for whom no etiologic agent was found by usual microbiologic investigations. Amoeba-associated bacteria might be a cause of VAP in ICUs, especially when microbiologic investigations are negative. PMID:12890321
Salivary cortisol and cortisone in the clinical setting.
Blair, Joanne; Adaway, Jo; Keevil, Brian; Ross, Richard
2017-06-01
A resurgence of interest in salivary biomarkers has generated evidence for their value in assessing adrenal function. The advantages of salivary measurements include only free hormone is detected, samples can be collected during normal daily routines and stress-induced cortisol release is less likely to occur than during venepuncture. We review the use of salivary biomarkers to diagnose and monitor patients for conditions of cortisol excess and deficiency and discuss the value of measuring salivary cortisone versus salivary cortisol. Developments in laboratory techniques have enabled the measurement of salivary hormones with a high level of sensitivity and specificity. In states of altered cortisol binding, salivary biomarkers are more accurate measures of adrenal reserve than serum cortisol. Salivary cortisone is a superior marker of serum cortisol compared with salivary cortisol, specifically when serum cortisol is low and during hydrocortisone therapy when contamination of saliva may result in misleading salivary cortisol concentrations. Salivary cortisol and cortisone can be used to assess cortisol excess, deficiency and hydrocortisone replacement, with salivary cortisone having the advantage of detection when serum cortisol levels are low and there is no interference from oral hydrocortisone.
Weitoft, T; Larsson, A; Rönnblom, L
2008-03-01
To study metalloproteinase activity and sex steroid hormone production in serum after intra-articular glucocorticoid treatment for knee synovitis. 18 female patients with rheumatoid arthritis and synovitis of the knee with need for intra-articular glucocorticoid treatment were included in this study. Serum samples of matrix metalloproteinases (MMP-1/TIMP complex and MMP-3), dehydroepiandrosterone sulphate, testosterone, oestradiol, steroid hormone binding globulin, follicle stimulating hormone and luteinising hormone were collected before injection with 20 mg triamcinolone hexacetonide, and 24 h, 48 h, 1 week and 2 weeks after injection, respectively. Serum levels of MMP-3 were significantly decreased, but MMP-1/TIMP complex was unaffected. Dehydroepiandrosterone sulphate, testosterone and oestradiol levels all decreased and tended to return to baseline levels during the observation period. Steroid hormone binding globulin, follicle stimulating hormone and luteinising hormone levels were unchanged. Intra-articular glucocorticoid treatment causes a temporary, but considerable suppression of sex steroid hormone secretion. The reduction of MMP-3 indicates an inhibition of the inflammatory, but probably also the cartilage destructive processes within the treated joint.
Cai, Tanxi; Yang, Fuquan
2017-01-01
Low-molecular-weight region (LMW, MW≤30kDa) of human serum/plasma proteins, including small intact proteins, truncated fragments of larger proteins, along with some other small components, has been associated with the ongoing physiological and pathological events, and thereby represent a treasure trove of diagnostic molecules. Great progress in the mining of novel biomarkers from this diagnostic treasure trove for disease diagnosis and health monitoring has been achieved based on serum samples from healthy individuals and patients and powerful new approaches in biochemistry and systems biology. However, cumulative evidence indicates that many potential LMW protein biomarkers might still have escaped from detection due to their low abundance, the dynamic complexity of serum/plasma, and the limited efficiency of characterization approaches. Here, we provide an overview of the current state of knowledge with respect to strategies for the characterization of low-abundant LMW proteins (small intact or truncated proteins) from human serum/plasma, involving prefractionation or enrichment methods to reduce dynamic range and mass spectrometry-based characterization of low-abundant LMW proteins. © 2017 Elsevier Inc. All rights reserved.
Lack of Serologic Evidence of Neospora caninum in Humans, England
McCann, Catherine M.; Vyse, Andrew J.; Salmon, Roland L; Thomas, Daniel; Williams, Diana J.L.; McGarry, John W.; Pebody, Richard
2008-01-01
Retrospective testing of 3,232 serum samples from the general population and 518 serum samples from a high-risk group showed no evidence of human exposure to Neospora caninum in England. Results were obtained by using immunofluorescence antibody testing and ELISA to analyze frequency distribution. PMID:18507920
Han, Bing; Yang, Qin; Luo, Xin-hua; He, Xiao-fei; Wu, Jun; Cheng, Ming-liang
2009-06-02
To compare and analyze the differential expression of proteins between coal-burning arsenism serum and normal human serum and identify the proteins related with arseniasis caused by coal-burning. Serum samples were collected from 6 normal subjects and 6 patients suffering from coal-burning arsenism. 2-DE was performed to separate serum proteins. After silver staining, the differential expression of proteins was analyzed and then identified by matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS). There were an average of 779 +/- 35 spots and 865 +/- 30 spots on 2-DE matching of two groups and the matching rate was 90.1% between two groups. From these two groups, 60 different protein spots were identified. Up-regulated expression was observed in 25 proteins and down-regulated expression in 35 proteins in the patient serum group. Among which 35 with differential expression above three times were singled out and MALDI-TOF-MS analysis was carried out on them. Thirteen proteins were identified, including keratin 10, apolipoprotein A-V, transferrin, alpha-1-antitrypsin, human zinc-alpha-2-glycoprotein, mitogen-activated protein kinase 3, vacuolar protein sorting 33A, O-linked GlcNAc transferase and etc. Up-regulated expression was observed in 5 proteins and down-regulated expression in 8 proteins in the patient serum group. The well-resolved and reproducible 2-DE serum patterns of patients suffering from coal-burning arsenism were established and some differentially expressed proteins characterized. These data will be used to screen the biomarker and to further study arseniasis caused by coal-burning.
Dimitris, Michelle C; Perumal, Nandita; Craig-Barnes, Hayley A; Leadley, Michael; Mahmud, Abdullah A; Baqui, Abdullah H; Roth, Daniel E
2016-04-01
Vitamin D status is conventionally defined by the serum concentration of 25-hydroxyvitamin D. However, it has been proposed that the serum cholecalciferol concentration (D3) also determines functional vitamin D sufficiency. The objective of this study was to describe the effect of weekly high-dose vitamin D3 supplementation on inter-dose serum D3 in pregnant women. We conducted a sub-study of a completed randomized double-blind placebo-controlled trial of vitamin D3 (35,000 IU/week) supplementation in late pregnancy (AViDD trial) in Dhaka, Bangladesh. This study included pregnant women enrolled at 26-29 weeks gestation who fully adhered to the prenatal supplement intervention for ≥8 consecutive weeks and for whom serum samples were available for D3 analysis (n=65). Serum D3 was uniformly low at enrolment. Mean D3 increased and was maximal at 1 day after vitamin D dose administration (152.09nmol/L, SD 25.11nmol/L) and remained significantly higher in VitD vs. Pl at 7 days (29.59nmol/L vs. 1.92nmol/L, p=0.007). Daily average of the group mean D3 during the week following dosing was 66.97nmol/L in VitD versus 2.13nmol/L in Pl. In conclusion, serum D3 remained significantly elevated throughout the week following ≥8 consecutive weekly doses of 35,000 IU D3 in pregnant women. However, the clinically significant minimum threshold of serum D3 remains to be established. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gaye, M. M.; Valentine, S. J.; Hu, Y.; Mirjankar, N.; Hammoud, Z. T.; Mechref, Y.; Lavine, B. K.; Clemmer, D. E.
2012-01-01
Three disease phenotypes, Barrett’s esophagus (BE), high-grade dysplasia (HGD), esophageal adenocarcinoma (EAC), and a set of normal control (NC) serum samples are examined using a combination of ion mobility spectrometry (IMS), mass spectrometry (MS) and principal component analysis (PCA) techniques. Samples from a total of 136 individuals were examined, including: 7 characterized as BE, 12 as HGD, 56 as EAC and 61 as NC. In typical datasets it was possible to assign ~20 to 30 glycan ions based on MS measurements. Ion mobility distributions for these ions show multiple features. In some cases, such as the [S1H5N4+3Na]3+ and [S1F1H5N4+3Na]3+ glycan ions, the ratio of intensities of high-mobility features to low-mobility features vary significantly for different groups. The degree to which such variations in mobility profiles can be used to distinguish phenotypes is evaluated for eleven N-linked glycan ions. An outlier analysis on each sample class followed by an unsupervised PCA using a genetic algorithm for pattern recognition reveals that EAC samples are separated from NC samples based on 46 features originating from the 11-glycan composite IMS distribution. PMID:23126309
Goitrous hypothyroidism associated with treatment with trimethoprim-sulfamethoxazole in a young dog.
Seelig, Davis M; Whittemore, Jacqueline C; Lappin, Michael R; Myers, Alan M; Avery, Paul R
2008-04-15
A 16-week-old female Boxer that had been treated for 5 weeks with trimethoprim-sulfamethoxazole and chloramphenicol because of aspiration pneumonia was evaluated for bilaterally symmetric masses in the subcutaneous tissues of the ventral neck, in the region of the larynx. Fine-needle aspirates were obtained from the neck masses; cytologic examination revealed well-differentiated thyroid epithelial tissue. A blood sample was collected for serum biochemical and thyroid function analyses. Mild hyperphosphatemia, severe hypercholesterolemia, mild hyperkalemia, and a mild increase in creatine kinase activity were identified. Serum concentration of total thyroxine was less than the lower reference limit, and that of thyroid-stimulating hormone was greater than the upper reference limit. Findings were consistent with a diagnosis of clinical hypothyroidism in a skeletally immature dog. Treatment with trimethoprim-sulfamethoxazole was discontinued. The dog was reevaluated 3 weeks later, at which time the neck masses were markedly decreased in size. Serum concentrations of cholesterol and potassium were lower; serum concentrations of total thyroxine and thyroid-stimulating hormone were near or within respective reference ranges. Age-appropriate increases in serum phosphorus concentration and serum alkaline phosphatase activity were also detected. To the authors' knowledge, this is the first report of antimicrobial-induced goiter in a dog. Cytologic examination of fine-needle aspirates and interpretation of data from serum biochemical and thyroid function analyses were needed to obtain a definitive diagnosis. Practitioners should include goiter among the differential diagnoses for ventral neck swellings in young dogs receiving potentiated sulfonamide antimicrobials.
A Routine 'Top-Down' Approach to Analysis of the Human Serum Proteome.
D'Silva, Arlene M; Hyett, Jon A; Coorssen, Jens R
2017-06-06
Serum provides a rich source of potential biomarker proteoforms. One of the major obstacles in analysing serum proteomes is detecting lower abundance proteins owing to the presence of hyper-abundant species (e.g., serum albumin and immunoglobulins). Although depletion methods have been used to address this, these can lead to the concomitant removal of non-targeted protein species, and thus raise issues of specificity, reproducibility, and the capacity for meaningful quantitative analyses. Altering the native stoichiometry of the proteome components may thus yield a more complex series of issues than dealing directly with the inherent complexity of the sample. Hence, here we targeted method refinements so as to ensure optimum resolution of serum proteomes via a top down two-dimensional gel electrophoresis (2DE) approach that enables the routine assessment of proteoforms and is fully compatible with subsequent mass spectrometric analyses. Testing included various fractionation and non-fractionation approaches. The data show that resolving 500 µg protein on 17 cm 3-10 non-linear immobilised pH gradient strips in the first dimension followed by second dimension resolution on 7-20% gradient gels with a combination of lithium dodecyl sulfate (LDS) and sodium dodecyl sulfate (SDS) detergents markedly improves the resolution and detection of proteoforms in serum. In addition, well established third dimension electrophoretic separations in combination with deep imaging further contributed to the best available resolution, detection, and thus quantitative top-down analysis of serum proteomes.
Zhao, Yongxi; Kong, Yu; Wang, Bo; Wu, Yayan; Wu, Hong
2007-03-30
A simple and rapid micellar electrokinetic chromatography (MEKC) method with UV detection was developed for the simultaneous separation and determination of all-trans- and 13-cis-retinoic acids in rabbit serum by on-line sweeping concentration technique. The serum sample was simply deproteinized and centrifuged. Various parameters affecting sample enrichment and separation were systematically investigated. Under optimal conditions, the analytes could be well separated within 17min, and the relative standard deviations (RSD) of migration times and peak areas were less than 3.4%. Compared with the conventional MEKC injection method, the 18- and 19-fold improvements in sensitivity were achieved, respectively. The proposed method has been successfully applied to the determination of all-trans- and 13-cis-retinoic acids in serum samples from rabbits and could be feasible for the further pharmacokinetics study of all-trans-retinoic acid.
Mihailovic-Vucinic, Violeta; Popevic, Ljubica; Popevic, Spasoje; Stjepanovic, Mihailo; Aleksic, Andjelka; Stanojevic-Paovic, Anka
2017-10-01
Many studies include elevated activity of angiotensin-converting enzyme (ACE) in serum in sarcoidosis and in ocular sarcoidosis as well, but there are only a few analyzing ACE activities in aqueous humor. The aim of this study is to illuminate the diagnostic value of ACE in aqueous humor in patients with ocular sarcoidosis. We analyzed twenty patients with ocular sarcoidosis and 18 patients with nonocular involvement. All patients have biopsy-positive sarcoidosis of the lungs and/or mediastinal lymph nodes. Blood samples for ACE serum levels were obtained from all patients. Aqueous humor samples were taken by paracentesis with a 25-gauge needle in local anesthesia. With appropriate statistical tests, we compared ACE activity in serum and aqueous humor in patients with and without ocular sarcoidosis. The majority of our patients with ocular sarcoidosis were female (12/20), also in the group with systemic sarcoidosis and without ocular involvement (12/6). Mean age of the whole analyzed group of sarcoidosis patients was 45 ± 6 years. There is no statistically significant difference in ACE activity in serum between two groups of patients (with and without ocular sarcoidosis). There is statistically significant difference in ACE activity in aqueous humor among patients with ocular and nonocular sarcoidosis. ACE activity in aqueous humor is significantly higher in patients with ocular sarcoidosis. Increased ACE activity in aqueous humor can point to a diagnosis of ocular sarcoidosis, without the need for ocular biopsy.
Relevance of matrix metalloproteases in non-small cell lung cancer diagnosis.
Blanco-Prieto, Sonia; Barcia-Castro, Leticia; Páez de la Cadena, María; Rodríguez-Berrocal, Francisco Javier; Vázquez-Iglesias, Lorena; Botana-Rial, María Isabel; Fernández-Villar, Alberto; De Chiara, Loretta
2017-12-05
The need for novel biomarkers that could aid in non-small cell lung cancer (NSCLC) detection, together with the relevance of Matrix Metalloproteases (MMPs) -1, -2, -7, -9 and -10 in lung tumorigenesis, prompted us to assess the diagnostic usefulness of these MMPs and the Tissue Inhibitor of Metalloproteinase (TIMP) -1 in NSCLC patients. Markers were evaluated in an initial study cohort (19 NSCLC cases and 19 healthy controls). Those that better performed were analyzed in a larger sample including patients with benign lung diseases. Serum MMPs and TIMP-1 were determined by multiplexed immunoassays. Logistic regression was employed for multivariate analysis of biomarker combinations. MMPs and TIMP-1 were elevated in the serum of NSCLC patients compared to healthy controls. MMP-1, -7 and -9 performed at best and were further evaluated in the sample including benign pathologies, corroborating the superiority of MMP-9 in NSCLC discrimination, also at early-stage NSCLC. The optimal diagnostic value was obtained with the model including MMP-9, gender, age and smoking history, that demonstrated an AUC of 0.787, 85.54% sensitivity and 64.89% specificity. Our results suggest that MMP-9 is a potential biomarker for NSCLC diagnosis and its combined measurement with other biomarkers could improve NSCLC detection.
Duque, Andrés; Martínez, Paula-Juliana; Giraldo, Astrid; Gualtero, Diego F.; Ardila, Carlos-Martín; Contreras, Adolfo; Duarte, Silvia
2017-01-01
Background The validity of the surveys on self-reported smoking status is often questioned because smokers underestimate cigarette use and deny the habit. It has been suggested that self-report should be accompanied by cotinine test. This report evaluates the usefulness of serum cotinine test to assess the association between smoking and periodontal status in a study with a large sample population to be used in studies with other serum markers in epidemiologic and periodontal medicine researches. Material and Methods 578 patients who were part of a multicenter study on blood biomarkers were evaluated about smoking and its relation to periodontal disease. Severity of periodontal disease was determinate using clinical attachment loss (CAL). Smoking was assessed by a questionnaire and a blood sample drawn for serum cotinine determination. Results The optimal cut-off point for serum cotinine was 10 ng/ml. Serum cotinine showed greater association with severity of CAL than self-report for mild-moderate CAL [OR 2.03 (CI95% 1.16-3.53) vs. OR 1.08 (CI95% 0.62-1.87) ] advanced periodontitis [OR 2.36 (CI95% 1.30- 4.31) vs. OR 2.06 (CI95% 0.97-4.38) ] and extension of CAL > 3 mm [ OR 1.78 (CI95% 1.16-1.71) vs. 1.37 (CI95% 0.89-2.11)]. When the two tests were evaluated together were not shown to be better than serum cotinine test. Conclusions Self-reported smoking and serum cotinine test ≥ 10ng/ml are accurate, complementary and more reliable methods to assess the patient’s smoking status and could be used in studies evaluating serum samples in large population and multicenter studies. Clinical Relevance: The serum cotinine level is more reliable to make associations with the patient’s periodontal status than self-report questionnaire and could be used in multicenter and periodontal medicine studies. Key words:Biological markers, serum, cotinine, periodontitis, smoking. PMID:28578367
van der Loos, Matthijs J H M; Haring, Robin; Rietveld, Cornelius A; Baumeister, Sebastian E; Groenen, Patrick J F; Hofman, Albert; de Jong, Frank H; Koellinger, Philipp D; Kohlmann, Thomas; Nauck, Matthias A; Rivadeneira, Fernando; Uitterlinden, André G; van Rooij, Frank J A; Wallaschofski, Henri; Thurik, A Roy
2013-07-02
Previous research has suggested a positive association between testosterone (T) and entrepreneurial behavior in males. However, this evidence was found in a study with a small sample size and has not been replicated. In the present study, we aimed to verify this association using two large, independent, population-based samples of males. We tested the association of T with entrepreneurial behavior, operationalized as self-employment, using data from the Rotterdam Study (N=587) and the Study of Health in Pomerania (N=1697). Total testosterone (TT) and sex hormone-binding globulin (SHBG) were measured in the serum. Free testosterone (FT), non-SHBG-bound T (non-SHBG-T), and the TT/SHBG ratio were calculated and used as measures of bioactive serum T, in addition to TT adjusted for SHBG. Using logistic regression models, we found no significant associations between any of the serum T measures and self-employment in either of the samples. To our knowledge, this is the first large-scale study on the relationship between serum T and entrepreneurial behavior. Copyright © 2013 Elsevier Inc. All rights reserved.
Ex vivo instability of glycated albumin: A role for autoxidative glycation.
Jeffs, Joshua W; Ferdosi, Shadi; Yassine, Hussein N; Borges, Chad R
2017-09-01
Ex vivo protein modifications occur within plasma and serum (P/S) samples due to prolonged exposure to the thawed state-which includes temperatures above -30 °C. Herein, the ex vivo glycation of human serum albumin from healthy and diabetic subjects was monitored in P/S samples stored for hours to months at -80 °C, -20 °C, and room temperature, as well as in samples subjected to multiple freeze-thaw cycles, incubated at different surface area-to-volume ratios or under different atmospheric compositions. A simple dilute-and-shoot method utilizing trap-and-elute LC-ESI-MS was employed to determine the relative abundances of the glycated forms of albumin-including forms of albumin bearing more than one glucose molecule. Significant increases in glycated albumin were found to occur within hours at room temperature, and within days at -20 °C. These increases continued over a period of 1-2 weeks at room temperature and over 200 days at -20 °C, ultimately resulting in a doubling of glycated albumin in both healthy and diabetic patients. It was also shown that samples stored at lower surface area-to-volume ratios or incubated under a nitrogen atmosphere experienced less rapid glucose adduction of albumin-suggesting a role for oxidative glycation in the ex vivo glycation of albumin. Copyright © 2017 Elsevier Inc. All rights reserved.
Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C
2015-01-01
In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from