Effect of Repeated Freezing and Thawing on 18 Clinical Chemistry Analytes in Rat Serum
Kale, Vijay P; Patel, Sweta G; Gunjal, Prashant S; Wakchaure, Santosh U; Sundar, Rajesh S; Ranvir, Ramchandra K; Jain, Mukul R
2012-01-01
In a preclinical research laboratory, using serum samples that have been frozen and thawed repeatedly is sometimes unavoidable when needing to confirm previous results or perform additional analysis. Here we determined the effects of multiple cycles of refrigeration or freezing and thawing of rat serum at 3 temperature conditions for different storage times on clinical chemistry analytes. Serum samples obtained from adult Wistar rats were stored at 2 to 8 °C and −10 to −20 °C for as long as 72 h and at −70 °C for as long as 30 d. At different time points (24, 48, and 72 h for samples stored at 2 to 8 °C or −10 to −20 °C and 1, 7, and 30 d for samples stored at −70 °C), the samples were brought to room temperature, analyzed, and then stored again at the designated temperature. The results obtained after each storage cycle were compared with those obtained from the initial analysis of fresh samples. Of the 18 serum analytes evaluated, 14 were stable without significant changes, even after 3 freeze–thaw cycles at the tested temperature ranges. Results from this study will help researchers working with rat serum to interpret the biochemical data obtained from serum samples that have been frozen and thawed repeatedly. PMID:23043814
Garner, Bridget C; Kuroki, Keiichi; Stoker, Aaron M; Cook, Cristi R; Cook, James L
2013-03-01
To identify proteins with differential expression between healthy dogs and dogs with stifle joint osteoarthritis secondary to cranial cruciate ligament (CCL) disease. Serum and synovial fluid samples obtained from dogs with stifle joint osteoarthritis before (n = 10) and after (8) surgery and control dogs without osteoarthritis (9) and archived synovial membrane and articular cartilage samples obtained from dogs with stifle joint osteoarthritis (5) and dogs without arthritis (5). Serum and synovial fluid samples were analyzed via liquid chromatography-tandem mass spectrometry; results were compared against a nonredundant protein database. Expression of complement component 3 in archived tissue samples was determined via immunohistochemical methods. No proteins had significantly different expression between serum samples of control dogs versus those of dogs with stifle joint osteoarthritis. Eleven proteins (complement component 3 precursor, complement factor I precursor, apolipoprotein B-100 precursor, serum paraoxonase and arylesterase 1, zinc-alpha-2-glycoprotein precursor, serum amyloid A, transthyretin precursor, retinol-binding protein 4 precursor, alpha-2-macroglobulin precursor, angiotensinogen precursor, and fibronectin 1 isoform 1 preproprotein) had significantly different expression (> 2.0-fold) between synovial fluid samples obtained before surgery from dogs with stifle joint osteoarthritis versus those obtained from control dogs. Complement component 3 was strongly expressed in all (5/5) synovial membrane samples of dogs with stifle joint osteoarthritis and weakly expressed in 3 of 5 synovial membrane samples of dogs without stifle joint arthritis. Findings suggested that the complement system and proteins involved in lipid and cholesterol metabolism may have a role in stifle joint osteoarthritis, CCL disease, or both.
NASA Astrophysics Data System (ADS)
Ivanov, A. I.; Zhbankov, R. G.; Korolenko, E. A.; Korolik, E. V.; Meleshchenko, L. A.; Sarnatskaya, V. V.; Nikolaev, V. G.; Nikolaichik, V. V.; Yushko, L. A.
1997-01-01
Differential scanning calorimetry and IR spectrosocopy were used to investigate the effect of the procedure of isolation of human serum albumin on its physicochemical characteristics. It is shown that fractionation of blood plasma with ethylene glycol followed by ion exchange chromatography can be used to obtain albumin of normal donors that is similar to the albumin in the nonfractionated plasma according to melting thermograms. Endotherms of human serum albumin samples that were obtained by affinity chromatography and preparative electrophoresis are bimodal, unlike the monophasic for albumin obtained by polyethylene glycol precipitation. These changes result from a higher content of nonetherified fatty acids in the albumin samples obtained by affinity chromatography and from modification of the secondary protein structure in the samples obtained by electrophoresis. Analysis of melting thermograms of serum albumin from patients with uremia, chronic hepatitis, and peritonitis shows that fractionation of blood with polyethylene glycol preserves the thermodynamic characteristics of the various pathological serum albumins to the greatest extent. The present results demonstrate the advantage of polyethylene glycol fractionation for isolation of native preparations of normal and “pathological” human serum albumin.
Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio
2012-01-01
Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296
Suarez-Diez, Maria; Adam, Jonathan; Adamski, Jerzy; Chasapi, Styliani A; Luchinat, Claudio; Peters, Annette; Prehn, Cornelia; Santucci, Claudio; Spyridonidis, Alexandros; Spyroulias, Georgios A; Tenori, Leonardo; Wang-Sattler, Rui; Saccenti, Edoardo
2017-07-07
Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA-MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids.
2017-01-01
Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA–MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids. PMID:28517934
Antibodies against MERS coronavirus in dromedary camels, United Arab Emirates, 2003 and 2013.
Meyer, Benjamin; Müller, Marcel A; Corman, Victor M; Reusken, Chantal B E M; Ritz, Daniel; Godeke, Gert-Jan; Lattwein, Erik; Kallies, Stephan; Siemens, Artem; van Beek, Janko; Drexler, Jan F; Muth, Doreen; Bosch, Berend-Jan; Wernery, Ulrich; Koopmans, Marion P G; Wernery, Renate; Drosten, Christian
2014-04-01
Middle East respiratory syndrome coronavirus (MERS-CoV) has caused an ongoing outbreak of severe acute respiratory tract infection in humans in the Arabian Peninsula since 2012. Dromedary camels have been implicated as possible viral reservoirs. We used serologic assays to analyze 651 dromedary camel serum samples from the United Arab Emirates; 151 of 651 samples were obtained in 2003, well before onset of the current epidemic, and 500 serum samples were obtained in 2013. Recombinant spike protein-specific immunofluorescence and virus neutralization tests enabled clear discrimination between MERS-CoV and bovine CoV infections. Most (632/651, 97.1%) camels had antibodies against MERS-CoV. This result included all 151 serum samples obtained in 2003. Most (389/651, 59.8%) serum samples had MERS-CoV-neutralizing antibody titers >1,280. Dromedary camels from the United Arab Emirates were infected at high rates with MERS-CoV or a closely related, probably conspecific, virus long before the first human MERS cases.
Lyssavirus Surveillance in Bats, Bangladesh
Niezgoda, Michael; Carroll, Darin S.; Keeler, Natalie; Hossain, Mohammed Jahangir; Breiman, Robert F.; Ksiazek, Thomas G.; Rupprecht, Charles E.
2006-01-01
Lyssavirus surveillance in bats was performed in Bangladesh during 2003 and 2004. No virus isolates were obtained. Three serum samples (all from Pteropus giganteus, n = 127) of 288 total serum samples, obtained from bats in 9 different taxa, neutralized lyssaviruses Aravan and Khujand. The infection occurs in bats in Bangladesh, but virus prevalence appears low. PMID:16704789
2015-10-01
screening. The project requires the use of serum samples obtained from at-risk subjects (heavy smokers with defined characteristics) undergoing...screening. The project requires the use of serum samples obtained from at-risk subjects (heavy smokers with defined characteristics) that were collected
Comparison of Schmallenberg virus antibody levels detected in milk and serum from individual cows.
Daly, Janet M; King, Barnabas; Tarlinton, Rachael A; Gough, Kevin C; Maddison, Ben C; Blowey, Roger
2015-03-11
Schmallenberg virus (SBV) is a recently emerged virus of ruminants in Europe. Enzyme-linked immunosorbent assays (ELISA) are commonly used to detect SBV-specific antibodies in bulk tank milk samples to monitor herd exposure to infection. However, it has previously been shown that a bulk tank milk sample can test positive even though the majority of cows within the herd are seronegative for SBV antibodies. Development of a pen-side test to detect antibodies in individual milk samples would potentially provide a cheaper test (for which samples are obtained non-invasively) than testing individual serum samples by ELISA. Therefore, the aim of this study was to investigate the agreement between antibody levels measured in milk and serum. Corresponding milk and serum samples from 88 cows in two dairy herds in the UK were tested for presence of immunoglobulin G antibodies to SBV using a commercially-available indirect ELISA. A serum neutralisation test (NT) was also performed as a gold standard assay. The ELISA values obtained for the bulk tank milk samples corresponded with the mean values for individual milk samples from each herd (bulk tank milk values were 58% and 73% and mean individual milk values 50% and 63% for herds A and B, respectively). Of the 88 serum samples tested in the NT, 82 (93%) were positive. Although at higher antibody levels, the ELISA values tended to be higher for the individual milk samples than for the corresponding serum samples, the positive predictive value for milk samples was 98% and for serum samples 94%. The serum ELISA was more likely to give false positive results around the lower cut-off value of the assay. The results indicate that testing of individual milk samples for antibodies against SBV by ELISA could be used to inform decisions in the management of dairy herds such as which, if any, animals to vaccinate.
Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc
2018-04-06
Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.
NASA Astrophysics Data System (ADS)
Rocha-Osornio, L. N.; Pichardo-Molina, J. L.; Barbosa-Garcia, O.; Frausto-Reyes, C.; Araujo-Andrade, C.; Huerta-Franco, R.; Gutiérrez-Juárez, G.
2008-02-01
Raman spectroscopy and Multivariate methods were used to study serum blood samples of control and breast cancer patients. Blood samples were obtained from 11 patients and 12 controls from the central region of Mexico. Our results show that principal component analysis is able to discriminate serum sample of breast cancer patients from those of control group, also the loading vectors of PCA plotted as a function of Raman shift shown which bands permitted to make the maximum discrimination between both groups of samples.
A comparison of serum and plasma cytokine values using a multiplexed assay in cats.
Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X
2016-12-01
Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, S. X.; Zhang, Y. J.; Zeng, Q. Y.; Li, L. F.; Guo, Z. Y.; Liu, Z. M.; Xiong, H. L.; Liu, S. H.
2014-06-01
Cancer is the most common disease to threaten human health. The ability to screen individuals with malignant tumours with only a blood sample would be greatly advantageous to early diagnosis and intervention. This study explores the possibility of discriminating between cancer patients and normal subjects with serum surface-enhanced Raman spectroscopy (SERS) and a support vector machine (SVM) through a peripheral blood sample. A total of 130 blood samples were obtained from patients with liver cancer, colonic cancer, esophageal cancer, nasopharyngeal cancer, gastric cancer, as well as 113 blood samples from normal volunteers. Several diagnostic models were built with the serum SERS spectra using SVM and principal component analysis (PCA) techniques. The results show that a diagnostic accuracy of 85.5% is acquired with a PCA algorithm, while a diagnostic accuracy of 95.8% is obtained using radial basis function (RBF), PCA-SVM methods. The results prove that a RBF kernel PCA-SVM technique is superior to PCA and conventional SVM (C-SVM) algorithms in classification serum SERS spectra. The study demonstrates that serum SERS, in combination with SVM techniques, has great potential for screening cancerous patients with any solid malignant tumour through a peripheral blood sample.
Ito, Hiroaki; Hasegawa, Katsuyuki; Hasegawa, Yuuki; Nishimaki, Tadashi; Hosomichi, Kazuyoshi; Kimura, Satoshi; Ohba, Motoi; Yao, Hiroshi; Onimaru, Manabu; Inoue, Ituro; Inoue, Haruhiro
2015-05-21
Blood tests, which are commonly used for cancer screening, generally have low sensitivity. Here, we developed a novel rapid and simple method to generate silver nanoscale hexagonal columns (NHCs) for use in surface-enhanced Raman scattering (SERS). We reported that the intensity of SERS spectra of clinical serum samples obtained from gastrointestinal cancer patients is was significantly higher than that of SERS spectra of clinical serum samples obtained from non-cancer patients. We estimated the combined constituents on silver NHCs by using a field emission-type scanning electron microscope, Raman microscopes, and a 3D laser scanning confocal microscope. We obtained the Raman scattering spectra of samples of physically fractured cells and clinical serum. No spectra were obtained for chemically lysed cultured cells and DNA, RNA, and protein extracted from cultured cells. We believe that our method, which uses SERS with silver NHCs to detect circulating nucleosomes bound by methylated cell-free DNA, may be successfully implemented in blood tests for cancer screening.
Garca, Mehmet Fatih; Demir, Halit; Turan, Mahfuz; Bozan, Nazım; Kozan, Ahmet; Belli, Şeyda Bayel; Arslan, Ayşe; Cankaya, Hakan
2014-06-01
To emphasize the effectiveness of adenosine deaminase (ADA) enzyme, which has important roles in the differentiation of lymphoid cells, and oxidative stress in patients with chronic tonsillitis. Serum and tissue samples were obtained from 25 patients who underwent tonsillectomy due to recurrent episodes of acute tonsillitis. In the control group, which also had 25 subjects, only serum samples were taken as obtaining tissue samples would not have been ethically appropriate. ADA enzyme activity, catalase (CAT), carbonic anhydrase (CA), nitric oxide (NO) and malondialdehyde (MDA) were measured in the serum and tissue samples of patients and control group subjects. The serum values of both groups were compared. In addition, the tissue and serum values of patients were compared. Serum ADA activity and the oxidant enzymes MDA and NO values of the patient group were significantly higher than those of the control group (p < 0.001), the antioxidant enzymes CA and CAT values of the patient group were significantly lower than those of the control group (p < 0.001). In addition, while CA, CAT and NO enzyme levels were found to be significantly higher in the tonsil tissue of the patient group when compared to serum levels (p < 0.05), there was no difference between tissue and serum MDA and ADA activity (p > 0.05). Elevated ADA activity may be effective in the pathogenesis of chronic tonsillitis both by impairing tissue structure and contributing to SOR formation.
Lack of Serologic Evidence of Neospora caninum in Humans, England
McCann, Catherine M.; Vyse, Andrew J.; Salmon, Roland L; Thomas, Daniel; Williams, Diana J.L.; McGarry, John W.; Pebody, Richard
2008-01-01
Retrospective testing of 3,232 serum samples from the general population and 518 serum samples from a high-risk group showed no evidence of human exposure to Neospora caninum in England. Results were obtained by using immunofluorescence antibody testing and ELISA to analyze frequency distribution. PMID:18507920
Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A
2006-06-01
To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.
NASA Astrophysics Data System (ADS)
Buoso, M. C.; Ceccato, D.; Moschini, G.; Bernardini, D.; Testoni, S.; Torboli, A.; Valdes, M.
2001-11-01
The assessment of selenium status of livestock plays an important role in the production of medicine since low serum Se levels influence disease resistance in ruminants. It has been proved that Se deficiency may cause muscular dystrophy, cardiomyopathy and even death. Serum level has been widely used to evaluate the Se short-term status in animals since there is a good association between serum Se level and the dietary intake of the element over a wide range. The purpose of this work was to determine the Se serum concentration in a population of 78 sucking 2-month-old calves, in order to corroborate a clinical diagnosis of severe deficiency status. The samples were analyzed by total reflection X-ray fluorescence (TXRF) at the ITAL STRUCTURES Research Laboratory. The results obtained from the serum samples presented Se concentrations varying from 10 to 66 ng/ml. The comparison between the obtained values and the expected serum selenium values (60-80 ng/ml), confirmed a mild to severe deficiency status in the investigated population.
Use of dried blood spots for the determination of serum concentrations of tamoxifen and endoxifen.
Jager, N G L; Rosing, H; Schellens, J H M; Beijnen, J H; Linn, S C
2014-07-01
The anti-estrogenic effect of tamoxifen is suggested to be mainly attributable to its metabolite (Z)-endoxifen, and a minimum therapeutic threshold for (Z)-endoxifen in serum has been proposed. The objective of this research was to establish the relationship between dried blood spot (DBS) and serum concentrations of tamoxifen and (Z)-endoxifen to allow the use of DBS sampling, a simple and patient-friendly alternative to venous sampling, in clinical practice. Paired DBS and serum samples were obtained from 50 patients using tamoxifen and analyzed using HPLC-MS/MS. Serum concentrations were calculated from DBS concentrations using the formula calculated serum concentration = DBS concentration/([1-haematocrit (Hct)] + blood cell-to-serum ratio × Hct). The blood cell-to-serum ratio was determined ex vivo by incubating a batch of whole blood spiked with both analytes. The average Hct for female adults was imputed as a fixed value. Calculated and analyzed serum concentrations were compared using weighted Deming regression. Weighted Deming regression analysis comparing 44 matching pairs of DBS and serum samples showed a proportional bias for both analytes. Serum concentrations were calculated using [Tamoxifen] serum, calculated = [Tamoxifen] DBS /0.779 and [(Z)-Endoxifen] serum, calculated = [(Z)-Endoxifen] DBS /0.663. Calculated serum concentrations were within 20 % of analyzed serum concentrations in 84 and 100 % of patient samples for tamoxifen and (Z)-endoxifen, respectively. In conclusion, DBS concentrations of tamoxifen and (Z)-endoxifen were equal to serum concentrations after correction for Hct and blood cell-to-serum ratio. DBS sampling can be used in clinical practice.
Long-term in vitro reactivity for HLA antibodies and comparison of detection using serum vs. plasma
Norris, Philip J.; Lee, Jar-How; Carrick, Danielle M.; Gottschall, Jerome L.; Lebedeva, Mila; de Castro, B.R.; Kleinman, Steven H.; Busch, Michael P.
2010-01-01
BACKGROUND HLA antibodies are a possible cause of transfusion-related acute lung injury (TRALI), and fluorescent bead assays are often used for antibody detection. Serum is the manufacturer’s recommended sample, but plasma may be easier to obtain for studies of HLA antibody prevalence and TRALI case investigations. STUDY DESIGN AND METHODS Specimens were obtained from 44 multiparous females positive for HLA antibodies by lymphocytotoxicity testing at least 13 years prior, and from 1,000 contemporary blood donors. Screening tests were performed using a Luminex-based assay. In addition to comparing results obtained with paired plasma and serum samples, the effects of storage at 4 °C for one week and of multiple freeze-thaw cycles were evaluated. RESULTS Of 42 evaluable subjects with HLA antibodies documented >13 years earlier, only 1 showed loss of detectable antibodies, with 39 (93%) positive in the screening assay for class I and 24 (57%) positive in the screening assay for HLA class II antibodies. In 968 evaluable contemporary donors, 291 screened positive for HLA class I and 206 for HLA class II antibodies using a low assay cut-off. Screening test concordance using paired plasma and serum samples was high, particularly for subjects with higher level antibodies. Refrigeration of samples for one week did not significantly affect assay results, while repeated freeze-thaw cycles caused a decrement in signal level. CONCLUSION Serum and plasma samples gave concordant results in the majority of cases, particularly for specimens with higher-level antibodies. High-level HLA antibodies were present in most individuals for over 13 years. PMID:18980615
Reproducibility of biomarkers in induced sputum and in serum from chronic smokers.
Zuiker, Rob G J A; Kamerling, Ingrid M C; Morelli, Nicoletta; Calderon, Cesar; Boot, J Diderik; de Kam, Marieke; Diamant, Zuzana; Burggraaf, Jacobus; Cohen, Adam F
2015-08-01
Soluble inflammatory markers obtained from non-invasive airway sampling such as induced sputum may be useful biomarkers for targeted pharmaceutical interventions. However, before these soluble markers can be used as potential targets, their variability and reproducibility need to be established in distinct study populations. This study aimed to assess the reproducibility of biomarkers obtained from induced sputum and serum in chronic smokers and non-smokers. Sputum and serum samples were obtained from 16 healthy non-smokers and 16 asymptomatic chronic smokers (for both groups: 8M/8F, 30-52 years, FEV1 ≥80% pred.; ≥10 pack years for the smokers) on 2 separate visits 4-10 days apart. Soluble markers in serum and sputum were analysed by ELISA. The differences between smokers vs non-smokers were analysed with a t-test and variability was assessed on log-transformed data by a mixed model ANOVA. Analysable sputum samples could be obtained from all 32 subjects. In both study populations neutrophils and macrophages were the predominant cell types. Serum Pulmonary Surfactant Associated Protein D had favourable reproducibility criteria for reliability ratio (0.99), intra-subject coefficient of variation (11.2%) and the Bland Altman limits of agreement. Furthermore, chronic smokers, compared to non-smokers, had significantly higher sputum concentrations of IL-8 (1094.6 pg/mL vs 460.8 pg/mL, p = 0.006)), and higher serum concentrations of Pulmonary Surfactant Associated Protein D (110.9 pg/mL vs 64.7 pg/mL, p = 0.019), and lower concentrations of Serum Amyloid A (1352.4 pg/mL vs 2297.5 pg/mL, p = 0.022). Serum Pulmonary Surfactant Associated Protein D proved to be a biomarker that fulfilled the criteria for reproducibility in both study groups. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sampling and analysis techniques for monitoring serum for trace elements.
Ericson, S P; McHalsky, M L; Rabinow, B E; Kronholm, K G; Arceo, C S; Weltzer, J A; Ayd, S W
1986-07-01
We describe techniques for controlling contamination in the sampling and analysis of human serum for trace metals. The relatively simple procedures do not require clean-room conditions. The atomic absorption and atomic emission methods used have been applied in studying zinc, copper, chromium, manganese, molybdenum, selenium, and aluminum concentrations. Values obtained for a group of 16 normal subjects agree with the most reliable values reported in the literature, obtained by much more elaborate techniques. All of these metals can be measured in 3 to 4 mL of serum. The methods may prove especially useful in monitoring concentrations of essential trace elements in blood of patients being maintained on total parenteral nutrition.
Inoue, K; Kato, K; Yoshimura, Y; Makino, T; Nakazawa, H
2000-11-10
A simple and sensitive method using high-performance liquid chromatography with multi-electrode electrochemical detection (HPLC-ED) including a coulometric array of four electrochemical sensors has been developed for the determination of bisphenol A in water and human serum. For good separation and detection of bisphenol A, a CAPCELL PAK UG 120 C18 reversed-phase column and a mobile phase consisting of 0.3% phosphoric acid-acetonitrile (60:40) were used. The detection limit obtained by the HPLC-ED method was 0.01 ng/ml (0.5 pg), which was more than 3000-times higher than the detection limit obtained by the ultraviolet (UV) method, and more than 200-times higher than the detection limit obtained by the fluorescence (FL) method. Bisphenol A in water and serum samples was pretreated by solid-phase extraction (SPE) after removing possible contamination derived from a plastic SPE cartridges and water used for the pretreatment. A trace amount (ND approximately 0.013 ng/ml) of bisphenol A was detected from the parts of cartridges (filtration column, sorbent bed and frits) by extraction with methanol, and it was completely removed by washing with at least 15 ml of methanol in the operation process. The concentrations of bisphenol A in tap water and Milli-Q-purified water were found to be 0.01 and 0.02 ng/ml, respectively. For that reason, bisphenol A-free water was made to trap bisphenol A in water using an Empore disk. In every pretreatment, SPE methods using bisphenol A-free water and washing with 15 ml of methanol were done in water and serum samples. The yields obtained from the recovery tests using water to which 0.5 or 0.05 ng/ml of bisphenol A was added were 83.8 to 98.2%, and the RSDs were 3.4 to 6.1%, respectively. The yields obtained from the recovery tests by OASIS HLB using serum to which 1.0 ng/ml or 0.1 ng/ml of bisphenol A was added were 79.0% and 87.3%, and the RSDs were 5.1% and 13.5%, respectively. The limits of quantification in water and serum sample were 0.01 ng/ml and 0.05 ng/ml, respectively. The method was applied to the determination of bisphenol A in healthy human serum sample, and the obtained detection was 0.32 ng/ml. From these results, the HPLC-ED method should be the most useful in the determination of bisphenol A at low concentration levels in water and biological samples.
Introduction of a rapid, simple radioimmunoassay and quality control scheme for thyroxine.
Nye, L; Hassan, M; Willmott, E; Landon, J
1976-01-01
A simple radioimmunoassay has been developed for service purposes to determine serum total thyroxine levels. Only three additions are required, of standard or sample, labelled thyroxine and antibody in polyethylene glycol. After 2 hours' incubation at room temperature the antibody-bound and free fractions are separated by centrifugation. Serum total thyroxine levels were measured in 195 euthyroid subjects and it was established that normal values lay within the range 57 to 155 nmol/1. Serial blood samples taken over a 24-hour period, from 11 subjects, indicated that there was no circadian rhythm so that samples for total thyroxine assay can be taken at any time of the day. Similar results were obtained using serum or plasma. Satisfactory results were obtained for three quality control sera when measured by seven different laboratories using this method. PMID:932232
Pilot Metabolome-Wide Association Study of Benzo(a)pyrene in Serum from Military Personnel
Walker, Douglas I.; Pennell, Kurt D.; Uppal, Karan; Xia, Xiaoyan; Hopke, Philip K.; Utell, Mark J.; Phipps, Richard P.; Sime, Patricia J.; Rohrbeck, Patricia; Mallon, COL Timothy M.; Jones, Dean P.
2016-01-01
Objective A pilot study was conducted to test the feasibility of using Department of Defense Serum Repository (DoDSR) samples to study health and exposure-related effects. Methods Thirty unidentified human serum samples were obtained from the DoDSR and analyzed for normal serum metabolites with high-resolution mass spectrometry and serum levels of free benzo(a)pyrene (BaP) by gas chromatography-mass spectrometry. Metabolic associations with BaP were determined using a metabolome wide association study (MWAS) and metabolic pathway enrichment. Results The serum analysis detected normal ranges of glucose, selected amino acids, fatty acids, and creatinine. Free BaP was detected in a broad concentration range. MWAS of BaP showed associations with lipids, fatty acids, and sulfur amino acid metabolic pathways. Conclusion The results show the DoDSR samples are of sufficient quality for chemical profiling of DoD personnel. PMID:27501104
Pilot Metabolome-Wide Association Study of Benzo(a)pyrene in Serum From Military Personnel.
Walker, Douglas I; Pennell, Kurt D; Uppal, Karan; Xia, Xiaoyan; Hopke, Philip K; Utell, Mark J; Phipps, Richard P; Sime, Patricia J; Rohrbeck, Patricia; Mallon, Col Timothy M; Jones, Dean P
2016-08-01
A pilot study was conducted to test the feasibility of using Department of Defense Serum Repository (DoDSR) samples to study health and exposure-related effects. Thirty unidentified human serum samples were obtained from the DoDSR and analyzed for normal serum metabolites with high-resolution mass spectrometry and serum levels of free benzo(a)pyrene (BaP) by gas chromatography-mass spectrometry. Metabolic associations with BaP were determined using a metabolome-wide association study (MWAS) and metabolic pathway enrichment. The serum analysis detected normal ranges of glucose, selected amino acids, fatty acids, and creatinine. Free BaP was detected in a broad concentration range. MWAS of BaP showed associations with lipids, fatty acids, and sulfur amino acid metabolic pathways. The results show that the DoDSR samples are of sufficient quality for chemical profiling of DoD personnel.
Gerloff, B J; Herdt, T H; Wells, W W; Liesman, J S; Emery, R S
1986-06-01
Percutaneous liver biopsies and blood samples were obtained from 80 multiparous dairy cows in nine Michigan herds. Biopsies and samples were obtained serially over the peripartum period. Thirty-nine cows received 17 g of supplemental myoinositol in the diet to test its use as a possible lipotropic substance and 41 received a placebo. Liver biopsies were assayed for triglyceride (TG) and total myoinositol content. Serum was assayed for dextran precipitable cholesterol and non-esterified fatty acids (NEFA). Inositol supplementation had no effect on any of the lipid variables. There was a significant herd effect on liver inositol, serum dextran precipitable cholesterol and NEFA concentrations. Serum NEFA and liver TG concentrations increased in the immediate postpartum period, while dextran precipitable cholesterol decreased. A significant herd X period interaction existed for liver TG and serum dextran precipitable cholesterol concentrations. Liver TG and serum NEFA concentrations were positively correlated. Excessive infiltration of bovine liver with lipid at calving appears to be an exaggerated manifestation of normal metabolic changes.
Sipa1l1 is an early biomarker of liver fibrosis in CCl4-treated rats
Marfà, Santiago; Morales-Ruiz, Manuel; Oró, Denise; Ribera, Jordi; Fernández-Varo, Guillermo; Jiménez, Wladimiro
2016-01-01
ABSTRACT At present, several procedures are used for staging liver fibrosis. However, these methods may involve clinical complications and/or present diagnostic uncertainty mainly in the early stages of the disease. Thus, this study was designed to unveil new non-invasive biomarkers of liver fibrosis in an in vivo model of fibrosis/cirrhosis induction by CCl4 inhalation by using a label-free quantitative LC-MS/MS approach. We analyzed 94 serum samples from adult Wistar rats with different degrees of liver fibrosis and 36 control rats. Firstly, serum samples from 18 CCl4-treated rats were clustered into three different groups according to the severity of hepatic and the serum proteome was characterized by label-free LC-MS/MS. Furthermore, three different pooled serum samples obtained from 16 control Wistar rats were also analyzed. Based on the proteomic data obtained, we performed a multivariate analysis which displayed three main cell signaling pathways altered in fibrosis. In cirrhosis, more biological imbalances were detected as well as multi-organ alterations. In addition, hemopexin and signal-induced proliferation-associated 1 like 1 (SIPA1L1) were selected as potential serum markers of liver fibrogenesis among all the analyzed proteins. The results were validated by ELISA in an independent group of 76 fibrotic/cirrhotic rats and 20 controls which confirmed SIPA1L1 as a potential non-invasive biomarker of liver fibrosis. In particular, SIPA1L1 showed a clear diminution in serum samples from fibrotic/cirrhotic rats and a great accuracy at identifying early fibrotic stages. In conclusion, the proteomic analysis of serum samples from CCl4-treated rats has enabled the identification of SIPA1L1 as a non-invasive marker of early liver fibrosis. PMID:27230648
[Serum glycosaminoglycans in Graves' disease patients].
Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław
2006-01-01
The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.
Analysis of serum and cerebrospinal fluid in clinically normal adult miniature donkeys.
Mozaffari, A A; Samadieh, H
2013-09-01
To establish reference intervals for serum and cerebrospinal fluid (CSF) parameters in clinically healthy adult miniature donkeys. Experiments were conducted on 10 female and 10 male clinically normal adult miniature donkeys, randomly selected from five herds. Lumbosacral CSF collection was performed with the sedated donkey in the standing position. Cell analysis was performed immediately after the samples were collected. Blood samples were obtained from the jugular vein immediately after CSF sample collection. Sodium, potassium, glucose, urea nitrogen, total protein, calcium, chloride, phosphorous and magnesium concentrations were measured in CSF and serum samples. A paired t-test was used to compare mean values between female and male donkeys. The CSF was uniformly clear, colourless and free from flocculent material, with a specific gravity of 1.002. The range of total nucleated cell counts was 2-4 cells/μL. The differential white cell count comprised only small lymphocytes. No erythrocytes or polymorphonuclear cells were observed on cytological examination. Reference values were obtained for biochemical analysis of serum and CSF. Gender had no effect on any variables measured in serum or CSF (p>0.05). CSF analysis can provide important information in addition to that gained by clinical examination. CSF analysis has not previously been performed in miniature donkeys; this is the first report on the subject. In the present study, reference intervals for total nucleated cell count, total protein, glucose, urea nitrogen, sodium, potassium, chloride, calcium, phosphorous and magnesium concentrations of serum and CSF were determined for male and female miniature donkeys.
Johns, Jennifer L.; Moorhead, Kaitlin A.; Hu, Jing; Moorhead, Roberta C.
2018-01-01
Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended. PMID:29497614
Serum Dried Samples to Detect Dengue Antibodies: A Field Study.
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Vazquez-Rosales, Guillermo; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Cevallos, Ana Maria; Xoconostle-Cazares, Beatriz; Lira, Rosalia
2017-01-01
Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µ l of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µ l. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Xoconostle-Cazares, Beatriz
2017-01-01
Background Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Methods Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion DSS samples are useful for detecting anti-dengue IgG antibodies in the field. PMID:28630868
Bead-based microfluidic immunoassay for diagnosis of Johne's disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wadhwa, Ashutosh; Foote, Robert; Shaw, Robert W
2012-01-01
Microfluidics technology offers a platform for development of point-of-care diagnostic devices for various infectious diseases. In this study, we examined whether serodiagnosis of Johne s disease (JD) can be conducted in a bead-based microfluidic assay system. Magnetic micro-beads were coated with antigens of the causative agent of JD, Mycobacterium avium subsp. paratuberculosis. The antigen-coated beads were incubated with serum samples of JD-positive or negative serum samples and then with a fluorescently-labeled secondary antibody (SAB). To confirm binding of serum antibodies to the antigen, the beads were subjected to flow cytometric analysis. Different conditions (dilutions of serum and SAB, types ofmore » SAB, and types of magnetic beads) were optimized for a great degree of differentiation between the JD-negative and JD-positive samples. Using the optimized conditions, we tested a well-classified set of 155 serum samples from JD negative and JD-positive cattle by using the bead-based flow cytometric assay. Of 105 JD-positive samples, 63 samples (60%) showed higher antibody binding levels than a cut-off value determined by using antibody binding levels of JD-negative samples. In contrast, only 43-49 JD-positive samples showed higher antibody binding levels than the cut-off value when the samples were tested by commercially-available immunoassays. Microfluidic assays were performed by magnetically immobilizing a number of beads within a microchannel of a glass microchip and detecting antibody on the collected beads by laser-induced fluorescence. Antigen-coated magnetic beads treated with bovine serum sample and fluorescently-labeled SAB were loaded into a microchannel to measure the fluorescence (reflecting level of antibody binding) on the beads in the microfluidic system. When the results of five bovine serum samples obtained with the system were compared to those obtained with the flow cytometer, a high level of correlation (linear regression, r2 = 0.994) was observed. In a further experiment, we magnetically immobilized antigen-coated beads in a microchannel, reacted the beads with serum and SAB in the channel, and detected antibody binding to the beads in the microfluidic system. A strong antibody binding in JD-positive serum was detected, whereas there was only negligible binding in negative control experiments. Our data suggest that the bead-based microfluidic system may form a basis for development of an on-site serodiagnosis of JD. Key Words: Mycobacterium avium ssp. paratuberculosis, Johne s disease, microfluidics, lab-on-a-chip.« less
p16 promoter hypermethylation: A useful serum marker for early detection of gastric cancer
Abbaszadegan, Mohammad Reza; Moaven, Omeed; Sima, Hamid Reza; Ghafarzadegan, Kamran; A'rabi, Azadeh; Forghani, Mohammad Naser; Raziee, Hamid Reza; Mashhadinejad, Ali; Jafarzadeh, Mostafa; Esmaili-Shandiz, Ehsan; Dadkhah, Ezzat
2008-01-01
AIM: To determine p16 promoter hypermethylation in gastric tumoral tissue and serum samples, its impact on p16-protein expression, and correlation with clinical and histological features. METHODS: Samples were obtained from 52 histologically confirmed cases of gastric adenocarcinoma. Gastric tissue and serum of 50 age- and sex-matched individuals with normal gastroscopy and biopsy were obtained as control samples. Methylation-specific polymerase chain reaction (MSP) was used to evaluate methylation status of p16 promoter. p16-protein expression was analyzed by immunohistochemical staining on paraffin-embedded sections. RESULTS: Methylation was detected in 44.2% (23/52) of tumoral tissues. 60.9% of them were also methylated in serum, i.e., 26.9% of all patients (14/52). Methylation was not detected in tissue and sera of control samples. p16-protein expression was decreased in 61.5% of cases (32/52), and was significantly associated with promoter hypermethylation (P < 0.001). Methylation was significantly more frequent in higher pathological grades (P < 0.05). Methylation was not associated with other clinicopathological features and environmental factors including H pylori infection and smoking. CONCLUSION: p16 promoter hypermethylation is an important event in gastric carcinogenesis. It is the principle mechanism of p16 gene silencing. It is related to malignant tumor behavior. Detection of DNA methylation in serum may be a biomarker for early detection of gastric cancer. PMID:18395906
Sato, Kenichi; Seimiya, Masanori; Kodera, Yoshio; Kitamura, Akihide; Nomura, Fumio
2010-02-01
Fourier-transform infrared (FT-IR) spectroscopy is a simple and reagent-free physicochemical analysis method, and is a potential alternative to more time-consuming and labor-intensive procedures. In this study, we aimed to use FT-IR spectroscopy to determine serum concentrations of chylomicron-triglyceride (TG) and very low density lipoprotein (VLDL)-TG. We analyzed a chylomicron fraction and VLDL fraction, which had been obtained by ultracentrifugation, to search for wavelengths to designate to each fraction. Then, partial least square (PLS) calibrations were developed using a training set of samples, for which TG concentrations had been determined by conventional procedures. Validation was conducted with another set of samples using the PLS model to predict serum TG concentrations on the basis of the samples' IR spectra. We analyzed a total of 150 samples. Serum concentrations of chylomicron-TG and VLDL-TG estimated by FT-IR spectroscopy agreed well with those obtained by the reference method (r=0.97 for both lipoprotein fractions). FT-IR spectrometric analysis required 15mul of serum and was completed within 1min. Serum chylomicron-TG and VLDL-TG concentrations can be determined with FT-IR spectroscopy. This rapid and simple test may have a great impact on the management of patients with dyslipidemia. Copyright 2009. Published by Elsevier B.V.
Detection of a Serum Siderophore by LC-MS/MS as a Potential Biomarker of Invasive Aspergillosis
Carroll, Cassandra S.; Amankwa, Lawrence N.; Pinto, Linda J.; Fuller, Jeffrey D.; Moore, Margo M.
2016-01-01
Invasive aspergillosis (IA) is a life-threatening systemic mycosis caused primarily by Aspergillus fumigatus. Early diagnosis of IA is based, in part, on an immunoassay for circulating fungal cell wall carbohydrate, galactomannan (GM). However, a wide range of sensitivity and specificity rates have been reported for the GM test across various patient populations. To obtain iron in vivo, A. fumigatus secretes the siderophore, N,N',N"-triacetylfusarinine C (TAFC) and we hypothesize that TAFC may represent a possible biomarker for early detection of IA. We developed an ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for TAFC analysis from serum, and measured TAFC in serum samples collected from patients at risk for IA. The method showed lower and upper limits of quantitation (LOQ) of 5 ng/ml and 750 ng/ml, respectively, and complete TAFC recovery from spiked serum. As proof of concept, we evaluated 76 serum samples from 58 patients with suspected IA that were investigated for the presence of GM. Fourteen serum samples obtained from 11 patients diagnosed with probable or proven IA were also analyzed for the presence of TAFC. Control sera (n = 16) were analyzed to establish a TAFC cut-off value (≥6 ng/ml). Of the 36 GM-positive samples (≥0.5 GM index) from suspected IA patients, TAFC was considered positive in 25 (69%). TAFC was also found in 28 additional GM-negative samples. TAFC was detected in 4 of the 14 samples (28%) from patients with proven/probable aspergillosis. Log-transformed TAFC and GM values from patients with proven/probable IA, healthy individuals and SLE patients showed a significant correlation with a Pearson r value of 0.77. In summary, we have developed a method for the detection of TAFC in serum that revealed this fungal product in the sera of patients at risk for invasive aspergillosis. A prospective study is warranted to determine whether this method provides improved early detection of IA. PMID:26974544
Organic cattle products: Authenticating production origin by analysis of serum mineral content.
Rodríguez-Bermúdez, Ruth; Herrero-Latorre, Carlos; López-Alonso, Marta; Losada, David E; Iglesias, Roberto; Miranda, Marta
2018-10-30
An authentication procedure for differentiating between organic and non-organic cattle production on the basis of analysis of serum samples has been developed. For this purpose, the concentrations of fourteen mineral elements (As, Cd, Co, Cr, Cu, Fe, Hg, I, Mn, Mo, Ni, Pb, Se and Zn) in 522 serum samples from cows (341 from organic farms and 181 from non-organic farms), determined by inductively coupled plasma spectrometry, were used. The chemical information provided by serum analysis was employed to construct different pattern recognition classification models that predict the origin of each sample: organic or non-organic class. Among all classification procedures considered, the best results were obtained with the decision tree C5.0, Random Forest and AdaBoost neural networks, with hit levels close to 90% for both production types. The proposed method, involving analysis of serum samples, provided rapid, accurate in vivo classification of cattle according to organic and non-organic production type. Copyright © 2018 Elsevier Ltd. All rights reserved.
Exposure of Piglets to Enteroviruses Investigated by an Immunoassay Based on the EV-G1 VP4 Peptide.
Benkahla, Mehdi A; Sane, Famara; Desailloud, Rachel; Hober, Didier
2016-01-01
The aim of this study was to investigate the exposure of piglets to enteroviruses-G (EV-G) through the presence of antibodies in their serum. Serum samples were obtained from the vena cava of 10 piglets at 9 weeks of age and again 39 days later (day 39). They were tested using an immunoassay based on the EV-G1 VP4 peptide, since VP4 is highly conserved among the four Enterovirus capsid proteins, and by using a seroneutralization assay. For each serum collected on day 39 the optical density was high compared to the value obtained in serum collected earlier (p = 0.002). However, the titers of anti-EV-G1 serum neutralizing activity were not different in paired samples (p > 0.999). The sequence alignment of the EV-G1 VP4 peptide, encompassing 50 amino acids, used in the immunoassay showed 88% homology with EV-G, suggesting that antibodies directed toward other EV-G than EV-G1 may be detected. An immunoassay based on EV-G1 VP4 can detect an increased level of EV-G antibodies in piglet serum samples. Further studies are needed to determine whether this immunoassay may be useful for diagnosis and/or epidemiological studies and to monitor EV-G infection in pigs to evaluate strategies aimed to prevent enterovirus infections. © 2016 S. Karger AG, Basel.
Oleinikov, Andrew V; Rossnagle, Eddie; Francis, Susan; Mutabingwa, Theonest K; Fried, Michal; Duffy, Patrick E
2007-07-01
Plasmodium falciparum-infected erythrocytes adhere to chondroitin sulfate A (CSA) to sequester in the human placenta, and pregnancy malaria (PM) is associated with the development of disease in and the death of both mother and child. A PM vaccine appears to be feasible, because women become protected as they develop antibodies against placental infected erythrocytes (IEs). Two IE surface molecules, VAR1CSA and VAR2CSA, bind CSA in vitro and are potential vaccine candidates. We expressed all domains of VAR1CSA and VAR2CSA as mammalian cell surface proteins, using a novel approach that allows rapid purification, immobilization, and quantification of target antigen. For serum samples from East Africa, we measured reactivity to all domains, and we examined the effects of host sex and parity, as well as the effects of parasite antigenic variation. Serum samples obtained from multigravid women had a higher reactivity to all VAR2CSA domains than did those obtained from primigravid women or from men. Conversely, serum samples obtained from men had consistently higher reactivity to VAR1CSA domains than did those obtained from gravid women. Seroreactivity was strongly influenced by antigenic variation of VAR2CSA Duffy binding-like domains. Women acquire antibodies to VAR2CSA over successive pregnancies, but they lose reactivity to VAR1CSA. Serum reactivity to VAR2CSA is variant specific, and future studies should examine the degree to which functional antibodies, such as binding-inhibition antibodies, are variant specific.
Specific IgA and IgG antibodies in paired serum and breast milk samples in human strongyloidiasis.
Mota-Ferreira, Daniela M L; Gonçalves-Pires, Maria do Rosário F; Júnior, Alvaro Ferreira; Sopelete, Mônica C; Abdallah, Vânia O S; Costa-Cruz, Julia M
2009-02-01
Strongyloidiasis, caused by the nematode Strongyloides stercoralis, is one of the major worldwide parasitic infections in humans. Breastfeeding may offer a potential protection against this infection. Feces, serum and milk samples were obtained from 90 lactating women from Clinical Hospital of Universidade Federal de Uberlândia, Brazil. The fecal samples were collected for parasitological diagnosis and the serum and milk samples were examined for specific S. stercoralis IgA and IgG antibodies using the indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assay (ELISA). Fecal examination showed that the rate of prevalence of S. stercoralis infection in the lactating women was 4.4%. IFAT manifested a 16.7% positivity rate for specific IgA antibody in serum and a 28.9% rate in milk samples; specific IgG was 41.1% in serum and 25.5% in milk samples. According to ELISA the positivity rate for specific IgA antibody was 21.1% in serum and 42.2% in milk samples; specific IgG was 40% in serum and 18.9% in milk samples. In serum samples, these immunological tests showed a concurrence of 91.1% and 94.4%, respectively, in detecting specific IgA and IgG antibodies. In milk samples, they showed a concurrence of 70% and 78.9%, respectively, in detecting specific IgA and IgG antibodies. There was a statistically significant difference between concordant and discordant results of immunological tests (P<0.0001). IFAT and ELISA highly concurred in their detection of specific S. stercoralis IgA and IgG antibodies in serum and in milk samples reconfirming prior studies that the serological method is a complement to the direct diagnosis of the parasite, and suggesting that immunological methods using milk samples can also be helpful. Furthermore, in endemic areas, infants may acquire antibodies to S. stercoralis from breast milk, possibly, contributing to the enhancement of specific mucosal immunity against this parasite.
Plut, Jan; Toplak, Ivan; Štukelj, Marina
2018-06-01
Over the last few years several porcine epidemic diarrhoea (PED) outbreaks have been discovered in Europe including the first PED case in Slovenia in January 2015. The aim of this study was to determine when PED virus (PEDV) infection started in Slovenia. Serum samples collected between 2012 and 2016 were tested. Three hundred and seventy-five serum samples were collected from 132 Slovenian small, one-site pig farms. Samples were tested for PEDV antibodies utilising three different serological methods: commercially-available indirect ELISA, in-house blocking ELISA test and Immunoperoxidase Monolayer Assay (IPMA) test. One hundred and seventy (45.33%) tested samples were found positive by the commercially-available ELISA test kit, and 10 (5.68%) of these 170 samples found positive were positive by the in-house blocking ELISA. Only these 10 samples were collected from a farm where clinical signs of PED infection had been observed and PEDV was confirmed by RT-PCR methodology; the other 160 samples were collected randomly. Thirty-two samples with the highest S/P value obtained with the commercial ELISA were all negative with IPMA. Reasons for the high variance in the results obtained remain unclear; more research is required to ensure higher sensitivity and specificity in terms of PEDV antibody tests and other PED diagnostic methods.
Gil, A.; González, A.; Dal-Ré, R.; Dominguez, V.; Astasio, P.; Aguilar, L.
1997-01-01
Diluted dried blood drops on filter paper were compared with serum samples as a specimen source for qualitative anti-HAV antibody determination by ELISA. A total of 298 serum samples and dried blood drops were collected from a population of healthy adolescents (15.3 +/- 1.2 years old). The prevalence of anti-HAV antibody obtained by testing serum samples was 7.7% (95% CI:4.8 10.1). Compared with serum sampling the sensitivity and specificity of diluted dried blood drops were 91.3 and 99.3%. The positive and negative predictive values were 91.3 and 99.3%, respectively, and the likelihood ratios of positive and negative results were 91 and 0.09. It is proposed that this test represents a reliable procedure for anti-HAV antibody testing. PMID:9129596
Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D
2014-04-01
The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.
Hayashi, Kuniki; Hoshino, Tadashi; Yanai, Mitsuru; Tsuchiya, Tatsuyuki; Kumasaka, Kazunari; Kawano, Kinya
2004-06-01
It is well known that serious method-related differences exist in results of serum CA19-9, and the necessity of standardization has been pointed out. In this study, differences of serum tumor marker CA19-9 levels obtained by various immunoassay kits (CLEIA, FEIA, LPIA and RIA) were evaluated in sixty-seven clinical samples and five calibrators and the possibility to improve the inter-methodological differences were observed not only for clinical samples but also for calibrators. We supposed an assumed standard material using by a calibrator. We calculated the serum levels of CA19-9 when using the assumed standard material for three different measurement methods. We approximate the CA19-9 values using by this method. It is suggested that the obtained CA19-9 values could be approximated by recalculation with the assumed standard material would be able to correct between-method and between-laboratory discrepancies in particular systematic errors.
NASA Astrophysics Data System (ADS)
Khetani, Altaf; Tiwari, Vidhu S.; Harb, Alaa; Anis, Hanan
2011-08-01
The feasibility of using hollow core photonic crystal fiber (HC-PCF) in conjunction with Raman spectroscopy has been explored for real time monitoring of heparin concentration in serum. Heparin is an important blood anti-coagulant whose precise monitoring and controlling in patients undergoing cardiac surgery and dialysis is of utmost importance. Our method of heparin monitoring offers a novel alternative to existing clinical procedures in terms of accuracy, response time and sample volume. The optical design configuration simply involves a 785-nm laser diode whose light is coupled into HC-PCF filled with heparin-serum mixtures. By non-selectively filling HC-PCF, a strong modal field overlap is obtained. Consequently, an enhanced Raman signal (>90 times) is obtained from various heparin-serum mixtures filled HC-PCFs compared to its bulk counterpart (cuvette). The present scheme has the potential to serve as a `generic biosensing tool' for diagnosing a wide range of biological samples.
Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C
2015-01-01
In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from
Gutiérrez-Zúñiga, Gabriela Guadalupe; Hernández-López, José Luis
2016-01-01
A gold millielectrode (GME) functionalized with a mixed (16-MHA + EG3SH) self-assembled monolayer (SAM) was used to fabricate an indirect enzyme-linked immunosorbent assay (ELISA) immunosensor for the sensitive detection of prostate-specific antigen (PSA), a prostate cancer (PCa) biomarker, in human serum samples. To address and minimize the issue of non-specific protein adsorption, an organic matrix (amine-PEG3-biotin/avidin) was assembled on the previously functionalized electrode surface to build up an ordered and hierarchically organized interfacial supramolecular architecture: Au/16-MHA/EG3SH/amine-PEG3-biotin/avidin. The electrode was then exposed to serum samples at different concentrations of a sandwich-type immunocomplex molecule ((Btn)Ab-AgPSA-(HRP)Ab), and its interfacial properties were characterized using electrochemical impedance spectroscopy (EIS). Calibration curves for polarization resistance (RP) and capacitance (1/C) vs. total and free PSA concentrations were obtained and their analytical quality parameters were determined. This approach was compared with results obtained from a commercially available ELISA immunosensor. The results obtained in this work showed that the proposed immunosensor can be successfully applied to analyze serum samples of patients representative of the Mexican population. Copyright © 2015 Elsevier B.V. All rights reserved.
Nyman, U; Lundberg, I; Hedfors, E; Wahren, M; Pettersson, I
1992-01-01
Sequentially obtained serum samples from 30 patients with connective tissue disease positive for antibody to ribonucleoprotein (RNP) were examined to determine the specificities of IgG and IgM antibodies to snRNP during the disease course using immunoblotting of nuclear extracts. The antibody patterns were correlated with disease activity. The patterns of antibody to snRNP of individual patients were mainly stable during the study but changes in levels of antibody to snRNP were seen corresponding to changes in clinical activity. These results indicate that increased reactivity of serum IgM antibodies against the B/B' proteins seems to precede a clinically evident exacerbation of disease whereas IgG antibody reactivity to the 70 K protein peaks at the time of a disease flare. Images PMID:1485812
Pedroza, Kelly C M C; de Matos, Sócrates B; de Moura, Daniel L; Oliveira, Mônica B B; Araújo, Marco A S; Nascimento, Roberto J M; Lima, Fernanda W M
2013-10-01
Galactomannan (GM) was recently included in consensus guidelines as an indirect mycological criterion for the diagnosis of invasive aspergillosis. Currently, there is an enzyme immunoassay available to detect GM in biological samples, the Platelia™ Aspergillus EIA. In this study, the reproducibility of positive results obtained using this assay was evaluated using serum samples from neutropenic patients. A trend toward lower values was observed, and 55 %(27/49) of positive results were negative after retesting. A low reproducibility of positive results for the detection of GM in serum was observed.
Heterophile antibody interference in qualitative urine/serum hCG devices: Case report.
Patel, Khushbu K; Gronowski, Ann M
2016-06-01
This case report investigates the origin of a false positive result on a serum qualitative human chorionic gonadotropin (hCG) device. A 46-year-old woman diagnosed with chronic myeloid leukemia presented with nausea and vomiting. A qualitative serum hCG test was interpreted as positive; however, a quantitative serum hCG test was negative (<5IU/L). To further investigate this discrepancy, the sample was pretreated with heterophilic blocking reagent (HBR). Additionally, the sample was tested on other qualitative hCG devices composed of antibodies from different animal sources. Blocking reagent from an automated quantitative immunoassay was also tested for its ability to inhibit the heterophile antibody interference. The qualitative test result was negative after pretreatment with heterophilic blocking reagent. Other devices composed of antibodies from different animal sources also demonstrated mixed results with the patient's sample. Blocking reagent obtained from the automated quantitative assay inhibited the heterophile antibody interference in the patient's sample. This case demonstrates that positive serum point-of-care hCG results should be interpreted with caution and confirmed with a quantitative serum hCG immunoassay when clinical suspicion is raised. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Jafari, M T; Rezaei, B; Zaker, B
2009-05-01
Application of ion mobility spectrometry (IMS) as the detection technique for a separation method based on molecular imprinted polymer (MIP) was investigated and evaluated for the first time. On the basis of the results obtained in this work, the MIP-IMS system can be used as a powerful technique for separation, preconcentration, and detection of the metronidazole drug in pharmaceutical and human serum samples. The method is exhaustively validated in terms of sensitivity, selectivity, recovery, reproducibility, and column capacity. The linear dynamic range of 0.05-70.00 microg/mL was obtained for the determination of metronidazole with IMS. The recovery of analyzed drug was calculated to be above 89%, and the relative standard deviation (RSD) was lower than 6% for all experiments. Various real samples were analyzed with the coupled techniques, and the results obtained revealed the efficient cleanup of the samples using MIP separation before the analysis by IMS as a detection technique.
Early Whole Blood for Patients Requiring Massive Transfusion after Major Trauma. Addendum
2013-10-01
process of determining which of the 45 patients had an abdominal CT. Measure serum (adipokines, leptin, adiponectin, and ghrelin ). We obtained serial...samples thru 24 hours on 60 patients and samples thru five days on 23 patients. We measured serum adiponectin, leptin, ghrelin , and resistin, and...adiponectin, leptin, and ghrelin were all lower in injured patients than in healthy volunteers at all timepoints. Adiponectin slowly decreased over time
Ajayi, O O; Charles-Davies, M A; Arinola, O G
2012-06-01
Environmental and endocrine factors have been implicated in the aetiology of recurrent abortion, with poorly understood roles. Luteal phase insufficiency marked with insufficient progesterone secretion has been reported. To define the involvement of progesterone, trace metals, and Vitamin E in pregnant women with history of recurrent spontaneous abortion. Convenience sampling method was used to recruit 69 pregnant women aged 21-41 years with gestational age of 0-20 weeks in this case-control study. Thirty five (cases) and thirty four (controls) had previous and no history of recurrent spontaneous abortion respectively. Demographic characteristics and 10 mls of blood samples were obtained from each subject. Serum obtained was used for the determination of progesterone, zinc, copper, selenium, iron, magnesium, manganese, chromium, lead, cadmium, and serum vitamin E by standard methods. Results showed statistically significant decreases (p<0.05) in the serum zinc, copper, and vitamin E and a significant elevation (p<0.05) in the serum selenium, lead, and cadmium in cases compared with controls. Insignificant decrease (p=0.07) was observed in the serum progesterone when cases were compared with controls. Results suggest that elevated serum heavy metals (cadmium and lead) and reduction of essential micronutrients (zinc, copper and vitamin E) may contribute to recurrent spontaneous abortion.
Effect of storage duration on cytokine stability in human serum and plasma.
Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James
2018-06-14
Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.
Wang, Michael Z; Howard, Brandon; Campa, Michael J; Patz, Edward F; Fitzgerald, Michael C
2003-09-01
Direct matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis of human serum yielded ion signals from only a fraction of the total number of peptides and proteins expected to be in the sample. We increased the number of peptide and protein ion signals observed in the MALDI-TOF mass spectra analysis of human serum by using a prefractionation protocol based on liquid phase isoelectric focusing electrophoresis. This pre-fractionation technique facilitated the MALDI-TOF MS detection of as many as 262 different peptide and protein ion signals from human serum. The results obtained from three replicate fractionation experiments on the same serum sample indicated that 148 different peptide and protein ion signals were reproducibly detected using our isoelectric focusing and MALDI-TOF MS protocol.
Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen
2016-03-01
Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time to diagnosis may be enhanced by testing multiple contemporaneously obtained sample types. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Serological tests for detecting Rift Valley fever viral antibodies in sheep from the Nile Delta.
Scott, R M; Feinsod, F M; Allam, I H; Ksiazek, T G; Peters, C J; Botros, B A; Darwish, M A
1986-01-01
To determine the accuracy of serological methods in detecting Rift Valley fever (RVF) viral antibodies, we examined serum samples obtained from 418 sheep in the Nile Delta by using five tests. The plaque reduction neutralization test (PRNT) was considered the standard serological method against which the four other tests were compared. Twenty-four serum samples had RVF viral antibodies detected by PRNT. Hemagglutination inhibition and enzyme-linked immunosorbent assay antibodies to RVF virus were also present in the same 24 serum samples. Indirect immunofluorescence was less sensitive in comparison with PRNT, and complement fixation was the least sensitive. These results extend observations made with laboratory animals to a large field-collected group of Egyptian sheep. PMID:3533977
Occurrence of West Nile virus antibodies in wild birds, horses, and humans in Poland.
Niczyporuk, Jowita Samanta; Samorek-Salamonowicz, Elżbieta; Lecollinet, Sylvie; Pancewicz, Sławomir Andrzej; Kozdruń, Wojciech; Czekaj, Hanna
2015-01-01
Serum samples of 474 wild birds, 378 horses, and 42 humans with meningitis and lymphocytic meningitis were collected between 2010 and 2014 from different areas of Poland. West Nile virus (WNV) antibodies were detected using competition enzyme linked immunosorbent assays: ELISA-1 ID Screen West Nile Competition, IDvet, ELISA-2 ID Screen West Nile IgM Capture, and ELISA-3 Ingezim West Nile Compac. The antibodies were found in 63 (13.29%) out of 474 wild bird serum samples and in one (0.26%) out of 378 horse serum samples. Fourteen (33.33%) out of 42 sera from patients were positive against WNV antigen and one serum was doubtful. Positive samples obtained in birds were next retested with virus microneutralisation test to confirm positive results and cross-reactions with other antigens of the Japanese encephalitis complex. We suspect that positive serological results in humans, birds, and horses indicate that WNV can be somehow closely related with the ecosystem in Poland.
Occurrence of West Nile Virus Antibodies in Wild Birds, Horses, and Humans in Poland
Niczyporuk, Jowita Samanta; Samorek-Salamonowicz, Elżbieta; Lecollinet, Sylvie; Pancewicz, Sławomir Andrzej; Kozdruń, Wojciech; Czekaj, Hanna
2015-01-01
Serum samples of 474 wild birds, 378 horses, and 42 humans with meningitis and lymphocytic meningitis were collected between 2010 and 2014 from different areas of Poland. West Nile virus (WNV) antibodies were detected using competition enzyme linked immunosorbent assays: ELISA-1 ID Screen West Nile Competition, IDvet, ELISA-2 ID Screen West Nile IgM Capture, and ELISA-3 Ingezim West Nile Compac. The antibodies were found in 63 (13.29%) out of 474 wild bird serum samples and in one (0.26%) out of 378 horse serum samples. Fourteen (33.33%) out of 42 sera from patients were positive against WNV antigen and one serum was doubtful. Positive samples obtained in birds were next retested with virus microneutralisation test to confirm positive results and cross-reactions with other antigens of the Japanese encephalitis complex. We suspect that positive serological results in humans, birds, and horses indicate that WNV can be somehow closely related with the ecosystem in Poland. PMID:25866767
Israeli, E; Grotto, I; Gilburd, B; Balicer, R D; Goldin, E; Wiik, A; Shoenfeld, Y
2005-09-01
Several antibodies have been reported in the sera of patients with Crohn's disease (CD) and ulcerative colitis (UC). The most commonly described are anti-Saccharomyces cerevisiae mannan antibodies (ASCA) in CD and perinuclear antineutrophil cytoplasm antibodies (pANCA) in UC. Familial clustering of these antibodies has been described, suggesting they might be genetic markers. Our aim was to investigate the presence of these antibodies before the emergence of overt clinical manifestations. Since 1980, the Israeli Defense Force (IDF) Medical Corps Serum Repository has stored serum samples obtained systematically from 5% of all recruits on enlistment, and from the same population on discharge from compulsory military service. We evaluated serum samples obtained from 32 subjects with CD and eight with UC before they were clinically diagnosed, along with samples from matched controls. ASCA were present in 10/32 (31.3%) CD patients before clinical diagnosis compared with 0/95 (0%) controls (p<0.001). None of the eight patients with serum samples available before diagnosis of UC were ASCA positive. ASCA was positive in 54.5% of patients after diagnosis of CD. The mean interval between ASCA detection and diagnosis was 38 months. In 90% of patients, antibodies were detected in the first available serum sample; therefore, measurements of the average time from the presence of ASCA to diagnosis may be even longer. pANCA were present in 2/8 (25%) patients with available sera before the diagnosis of UC. None of their 24 matched controls were positive (p = 0.014). ASCA and pANCA may predict development of inflammatory bowel disease years before the disease is clinically diagnosed.
Nucleic Acid-Based Cross-Linking Assay for Detection and Quantification of Hepatitis B Virus DNA
Lai, Vicky C. H.; Guan, Richard; Wood, Michael L.; Lo, Su Kong; Yuen, Man-Fung; Lai, Ching-Lung
1999-01-01
A nucleic acid photo-cross-linking technology was used to develop a direct assay for the quantification of hepatitis B virus (HBV) DNA levels in serum. Cross-linker-modified DNA probes complementary to the viral genomes of the major HBV subtypes were synthesized and used in an assay that could be completed in less than 6 h. The quantification range of the assay, as determined by testing serial dilutions of Eurohep HBV reference standards and cloned HBV DNA, was 5 × 105 to 3 × 109 molecules of HBV DNA/ml of serum. Within-run and between-run coefficients of variation (CVs) for the assay were 4.3 and 4.0%, respectively. The assay was used to determine HBV DNA levels in 302 serum samples, and the results were compared to those obtained after testing the same samples with the Chiron branched-DNA (bDNA) assay for HBV DNA. Of the samples tested, 218 were positive for HBV DNA by both assays and 72 gave results below the cutoff for both assays. Of the remaining 12 samples, 10 were positive for HBV DNA by the cross-linking assay only; the 2 other samples were positive by the bDNA assay only. Twenty-eight samples had to be retested by the bDNA assay (CV, >20% between the results obtained from the testing of each sample in duplicate), whereas only three samples required retesting by the cross-linking assay. The correlation between the HBV DNA levels, as measured by the two tests, was very high (r = 0.902; P = 0.01). We conclude that the cross-linking assay is a sensitive and reproducible method for the detection and quantification of HBV DNA levels in serum. PMID:9854083
Yellow Fever Outbreak, Imatong, Southern Sudan
Ofula, Victor O.; Sang, Rosemary C.; Konongoi, Samson L.; Sow, Abdourahmane; De Cock, Kevin M.; Tukei, Peter M.; Okoth, Fredrick A.; Swanepoel, Robert; Burt, Felicity J.; Waters, Norman C.; Coldren, Rodney L.
2004-01-01
In May 2003, the World Health Organization received reports about a possible outbreak of a hemorrhagic disease of unknown cause in the Imatong Mountains of southern Sudan. Laboratory investigations were conducted on 28 serum samples collected from patients in the Imatong region. Serum samples from 13 patients were positive for immunoglobulin M antibody to flavivirus, and serum samples from 5 patients were positive by reverse transcription–polymerase chain reaction with both the genus Flavivirus–reactive primers and yellow fever virus–specific primers. Nucleotide sequencing of the amplicons obtained with the genus Flavivirus oligonucleotide primers confirmed yellow fever virus as the etiologic agent. Isolation attempts in newborn mice and Vero cells from the samples yielded virus isolates from five patients. Rapid and accurate laboratory diagnosis enabled an interagency emergency task force to initiate a targeted vaccination campaign to control the outbreak. PMID:15207058
Cremer, N E; Cossen, C K; Hanson, C V; Shell, G R
1982-01-01
Several methods for evaluating and reporting enzyme immunoassay (EIA) determinations of antibody to herpes simplex virus derived from one dilution of single serum samples were studied. An EIA ratio method for serological evidence of current infection from paired serum samples was also evaluated. Optical density (OD) of the reaction at a 1:100 serum dilution and estimated titers obtained by reference of the OD of the serum dilution to a standard curve were compared to the corresponding plotted EIA titer obtained by titration to endpoint. Neither the OD per se nor the estimated titer was completely predictive of the plotted titer (correlation coefficient [r] of 0.824 and 0.817, respectively), and they provided only a semiquantitative measurement of antibody concentration. For an antibody status report, however, OD would be sufficient if related to the cutoff value as an EIA index (OD of sample divided by cutoff OD for positive specimens). The OD of the EIA reaction at a single dilution (1:5) of cerebrospinal fluid, on the other hand, correlated quite well with the titer obtained by titration (r = 0.950). For serological diagnosis of current infection, the OD ratio of convalescence-phase/acute-phase sera was determined at several dilutions. A ratio of greater than or equal to 1.54 was calculated as a reliable index for a significant rise in antibody concentration and compatible with current infection. By determining the convalescent-phase/acute-phase serum ratio at two dilutions, 1:100 and 1:1,000, the EIA ratio method appeared to be a sensitive as or more sensitive than, complement fixation in diagnosing current infection. PMID:6284791
Amoeba-Resisting Bacteria and Ventilator-Associated Pneumonia
La Scola, Bernard; Boyadjiev, Ioanna; Greub, Gilbert; Khamis, Atieh; Martin, Claude
2003-01-01
To evaluate the role of amoeba-associated bacteria as agents of ventilator-associated pneumonia (VAP), we tested the water from an intensive care unit (ICU) every week for 6 months for such bacteria isolates; serum samples and bronchoalveolar lavage samples (BAL) were also obtained from 30 ICU patients. BAL samples were examined for amoeba-associated bacteria DNA by suicide-polymerase chain reaction, and serum samples were tested against ICU amoeba-associated bacteria. A total of 310 amoeba-associated bacteria from10 species were isolated. Twelve of 30 serum samples seroconverted to one amoeba-associated bacterium isolated in the ICU, mainly Legionella anisa and Bosea massiliensis, the most common isolates from water (p=0.021). Amoeba-associated bacteria DNA was detected in BAL samples from two patients whose samples later seroconverted. Seroconversion was significantly associated with VAP and systemic inflammatory response syndrome, especially in patients for whom no etiologic agent was found by usual microbiologic investigations. Amoeba-associated bacteria might be a cause of VAP in ICUs, especially when microbiologic investigations are negative. PMID:12890321
NASA Astrophysics Data System (ADS)
Hernández-Caraballo, Edwin A.; Burguera, Marcela; Burguera, José L.
2002-12-01
A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH 4OH+0.05% w/v Triton X-100 ®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO 3) 2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1 -1 Se, corresponding to 30 μg l -1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l -1, with a mean value of 114±22 μg l -1.
Serum prolactin in coeliac disease: a marker for disease activity
Reifen, R.; Buskila, D.; Maislos, M.; Press, J.; Lerner, A.
1997-01-01
Accepted 21 April 1997 Prolactin, a polypeptide hormone of anterior pituitary origin, has pronounced physiological effects on growth, reproduction, and osmoregulation. Increasing evidence indicates that prolactin also has an immunomodulatory influence on the immune system. The status of prolactin in patients with coeliac disease was investigated by obtaining serum samples from 48 patients with active and non-active coeliac disease. These were compared with samples from 20 children with familial Mediterranean fever and 65 normal controls. Serum prolactin in patients with active coeliac disease was significantly higher than in the other groups studied and reference values. Serum prolactin correlated well with the degree of mucosal atrophy and with the serum concentration of antiendomysial antibodies. Prolactin may play a part in immune modulation in the intestinal damage of coeliac disease and serve as a potential marker for disease activity. PMID:9301358
Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A
1993-01-01
The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.
[Detection of antibodies against enterovirus 71 in the sera of Moscow residents].
Kravchenko, A T; Omel'chenko, T N
1984-03-01
Twenty three out of 55 serum samples obtained from subjects aged 20-55 years have proved to be seropositive, 15 of the positive serum samples (i.e. more than 50%) possessing the titer greater than or equal to 1:16. The presence of specific antibodies in the sera of the inhabitants of Moscow suggests that either enterovirus 71 or some other virus whose antigens are partly identical to those of enterovirus 71 apparently circulates among the population of Moscow.
Some comments on the effectiveness of the therapy for Β-thalassemia
NASA Astrophysics Data System (ADS)
Jiang, K.; Ma, W. Y.; Ortalli, I.; Pedrazzi, G.; Zhang, X.; Izzi, G. C.
1994-12-01
In the present study, twenty-five samples of red blood cells (RBCs) and two samples of lyophilized serum, drawn from thirteen patients with Β-thanassemia major, have been examined by Mössbauer spectroscopy. All these patients undergo long-term therapy by regular blood transfusion and deferoxamine. The samples were obtained at the end of one cycle of treatments, before the successive blood transfusion. The results show, within the experimental errors, that the ferritin-like iron appears to be absent in the RBCs of the patients but it is still present in the serum.
Chiem, N H; Harrison, D J
1998-03-01
A glass microchip is described in which reagents and serum samples for competitive immunoassay of serum theophylline can be mixed, reacted, separated, and analyzed. The device functions as an automated microfluidic immunoassay system, creating a lab-on-a-chip. Electroosmotic pumping was used to control first the mixing of 50-fold-diluted serum sample with labeled theophylline tracer in a 1:1 ratio, followed by 1:1 mixing and reaction with anti-theophylline antibody. The 51-nL on-chip mixer gave the same concentration as dilution performed off-chip, within 3%. A 100-pL plug of the reacted solution was then injected into an electrophoresis separation channel integrated within the same chip. Measurements of free and bound tracer by fluorescence detection gave linear calibration curves of signal vs log[theophylline] between 0 and 40 mg/L, with a slope of 0.52 +/- 0.03 and an intercept of -0.04 +/- 0.04 after a 90-s reaction time. A detection limit of 0.26 mg/L in serum (expressed before the dilution step, actual concentration of 1.3 micrograms/L at the detector) was obtained. Recovery values were 107% +/- 8% for 15 mg/L serum samples.
Loeffler, David A; Klaver, Andrea C
2017-11-01
Specific antibody concentrations are frequently measured in serum (and plasma and intravenous immunoglobulin) samples by enzyme-linked immunosorbent assay (ELISA). The standard negative control involves incubation of buffer alone on antigen-coated wells. The immunoreactivity that develops in antigen-coated wells in which diluted serum has been incubated is assumed to represent specific antibody binding. This approach can result in marked overestimation of specific antibody levels, because serum contains specific polyvalent antibodies which bind, primarily with low affinity, to multiple antigens (including those on ELISA plates) despite the use of blocking agents. Non-denaturing purification of serum IgG, followed by assessment of the antigen binding or antigen-binding affinity of this purified IgG, can reduce but not eliminate the problem of polyvalent antibody binding in indirect ELISAs. Alternatively, polyvalent antibody binding can be estimated by incubating a diluted serum sample on wells coated with an irrelevant protein (such as bovine serum albumin or a scrambled peptide sequence) or buffer alone, then subtracting this reactivity from the sample's binding to wells coated with the antigen of interest. Polyvalent binding of immunoglobulins must be accounted for in order to obtain accurate ELISA measurements of serum, plasma, or intravenous immunoglobulin antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
Nipah Virus in Lyle's Flying Foxes, Cambodia
Counor, Dorian; Ong, Sivuth; Faure, Caroline; Seng, Vansay; Molia, Sophie; Walston, Joe; Georges-Courbot, Marie Claude; Deubel, Vincent; Sarthou, Jean-Louis
2005-01-01
We conducted a survey in Cambodia in 2000 on henipavirus infection among several bat species, including flying foxes, and persons exposed to these animals. Among 1,072 bat serum samples tested by enzyme-linked immunosorbent assay, antibodies reactive to Nipah virus (NiV) antigen were detected only in Pteropus lylei species; Cynopterus sphinx, Hipposideros larvatus, Scotophilus kuhlii, Chaerephon plicata, Taphozous melanopogon, and T. theobaldi species were negative. Seroneutralization applied on a subset of 156 serum samples confirmed these results. None of the 8 human serum samples was NiV seropositive with the seroneutralization test. One virus isolate exhibiting cytopathic effect with syncytia was obtained from 769 urine samples collected at roosts of P. lylei specimens. Partial molecular characterization of this isolate demonstrated that it was closely related to NiV. These results strengthen the hypothesis that flying foxes could be the natural host of NiV. Surveillance of human cases should be implemented. PMID:16022778
Lindberger, Martin; Luhr, Owe; Johannessen, Svein I; Larsson, Sirkku; Tomson, Torbjörn
2003-08-01
To explore possible concentration-effect relationships, gabapentin (GBP) and vigabatrin (VGB) serum concentrations were obtained from patients participating in an add-on dose-titration trial comparing GBP and VGB in partial epilepsy. Patients randomized to GBP started on 1800 mg/d and could have their dosage increased stepwise to 2400 and 3600 mg/d if seizures persisted. Those randomised to VGB started on 1000 mg/d, and the dose could be increased to 2000 and 4000 mg/d. Blood samples were obtained at steady state, at a nonstandardized time, from 27 patients randomized to GBP and from 36 randomized to VGB. Serum samples were analyzed using high-performance liquid chromatography. The treatment effect was expressed as percentage reduction in number of seizures from baseline. In addition, patients were classified as responders (>50% reduction in number of seizures from baseline) or nonresponders. There was no significant correlation between serum concentrations of GBP and seizure reduction at the lowest dosage, 1800 mg/d (r = -0.02, P = 0.94, Spearman-rank), nor between VGB serum levels and seizure reduction at 1000 mg/d of VGB (r = -0.14, P = 0.44). The serum GBP concentrations among responders to GBP 1800 mg/d were 26 +/- 12 micro mol/L (mean +/- SD), which was not different from serum concentrations in nonresponders, 28+/-13 micro mol/L. Nor was there a difference between serum concentrations of responders and nonresponders to VGB 1000 mg/d (32 +/- 23 and 44 +/- 36 micro mol/L, respectively). Hence, with the present study design we were unable to identify specific target ranges of GBP and VGB serum concentrations.
Browne, J L; Schielen, P C J I; Belmouden, I; Pennings, J L A; Klipstein-Grobusch, K
2015-06-01
The objectives of the article is to compare pregnancy-associated plasma protein A (PAPP-A) and free β-subunit of human chorionic gonadotropin (β-hCG) concentrations in dried blood spots (DBSs) with serum of samples obtained from a public hospital in a low-resource setting and to evaluate their stability. Serum and DBS samples were obtained by venipuncture and finger prick from 50 pregnant participants in a cohort study in a public hospital in Accra, Ghana. PAPP-A and β-hCG concentrations from serum and DBS were measured with an AutoDELFIA® (PerkinElmer, PerkinElmer, Turku, Finland) automatic immunoassay. Correlation and Passing-Bablok regression analyses were performed to compare marker levels. High correlation (>0.9) was observed for PAPP-A and β-hCG levels between various sampling techniques. The β-hCG concentration was stable between DBS and serum, PAPP-A concentration consistently lower in DBS. Our findings suggest that β-hCG can be reliably collected from DBS in low-resource tropical settings. The exact conditions of the clinical workflow necessary for reliable PAPP-A measurement in these settings need to be further developed in the future. These findings could have implications for prenatal screening programs feasibility in low-income and middle-income countries, as DBS provides an alternative minimally invasive sampling method, with advantages in sampling technique, stability, logistics, and potential application in low-resource settings. © 2015 John Wiley & Sons, Ltd.
How the reference values for serum parathyroid hormone concentration are (or should be) established?
Souberbielle, J-C; Brazier, F; Piketty, M-L; Cormier, C; Minisola, S; Cavalier, E
2017-03-01
Well-validated reference values are necessary for a correct interpretation of a serum PTH concentration. Establishing PTH reference values needs recruiting a large reference population. Exclusion criteria for this population can be defined as any situation possibly inducing an increase or a decrease in PTH concentration. As recommended in the recent guidelines on the diagnosis and management of asymptomatic primary hyperparathyroidism, PTH reference values should be established in vitamin D-replete subjects with a normal renal function with possible stratification according to various factors such as age, gender, menopausal status, body mass index, and race. A consensus about analytical/pre-analytical aspects of PTH measurement is also needed with special emphasis on the nature of the sample (plasma or serum), the time and the fasting/non-fasting status of the blood sample. Our opinion is that blood sample for PTH measurement should be obtained in the morning after an overnight fast. Furthermore, despite longer stability of the PTH molecule in EDTA plasma, we prefer serum as it allows to measure calcium, a prerequisite for a correct interpretation of a PTH concentration, on the same sample. Once a consensus is reached, we believe an important international multicentre work should be performed to recruit a very extensive reference population of apparently healthy vitamin D-replete subjects with a normal renal function in order to establish the PTH normative data. Due to the huge inter-method variability in PTH measurement, a sufficient quantity of blood sample should be obtained to allow measurement with as many PTH kits as possible.
Single point estimation of phenytoin dosing: a reappraisal.
Koup, J R; Gibaldi, M; Godolphin, W
1981-11-01
A previously proposed method for estimation of phenytoin dosing requirement using a single serum sample obtained 24 hours after intravenous loading dose (18 mg/Kg) has been re-evaluated. Using more realistic values for the volume of distribution of phenytoin (0.4 to 1.2 L/Kg), simulations indicate that the proposed method will fail to consistently predict dosage requirements. Additional simulations indicate that two samples obtained during the 24 hour interval following the iv loading dose could be used to more reliably predict phenytoin dose requirement. Because of the nonlinear relationship which exists between phenytoin dose administration rate (RO) and the mean steady state serum concentration (CSS), small errors in prediction of the required RO result in much larger errors in CSS.
Tinkov, Alexey A; Skalnaya, Margarita G; Demidov, Vasily A; Serebryansky, Eugeny P; Nikonorov, Alexandr A; Skalny, Anatoly V
2014-12-01
The primary objective of the research is to estimate the dependence between hair mercury content, hair selenium, mercury-to-selenium ratio, serum lipid spectrum, and gamma-glutamyl transferase (GGT) activity in 63 adults (40 men and 23 women). Serum triglyceride (TG) concentration in the high-mercury group significantly exceeded the values obtained for low- and medium-mercury groups by 72 and 42 %, respectively. Serum GGT activity in the examinees from high-Hg group significantly exceeded the values of the first and the second groups by 75 and 28 %, respectively. Statistical analysis of the male sample revealed similar dependences. Surprisingly, no significant changes in the parameters analyzed were detected in the female sample. In all analyzed samples, hair mercury was not associated with hair selenium concentrations. Significant correlation between hair mercury content and serum TG concentration (r = 0.531) and GGT activity (r = 0.524) in the general sample of the examinees was detected. The respective correlations were observed in the male sample. Hair mercury-to-selenium ratios significantly correlated with body weight (r = 0.310), body mass index (r = 0.250), serum TG (r = 0.389), atherogenic index (r = 0.257), and GGT activity (r = 0.393). The same correlations were observed in the male sample. Hg/Se ratio in women did not correlate with the analyzed parameters. Generally, the results of the current study show the following: (1) hair mercury is associated with serum TG concentration and GGT activity in men, (2) hair selenium content is not related to hair mercury concentration, and (3) mercury-to-selenium ratio correlates with lipid spectrum parameters and GGT activity.
Samlıoğlu, Pınar; Unalp, Aycan; Gökçay, Ahmet; Altuğlu, Imre; Oztürk, Aysel; Zeytinoğlu, Ayşın
2012-10-01
Subacute sclerosing panencephalitis (SSPE) caused by persistent defective measles virus strains, is a progressive neurological disorder of children and adolescents. The aim of this letter was to share the data from SSPE-suspected cases who were definitely diagnosed by the detection of increased antibody index in serum and cerebrospinal fluid (CSF) samples. A total of 11 patients (mean age: 14.3 years) with suspected SSPE between February 2006 to August 2008, were included in the study. Simultaneously obtained serum and CSF samples from patients were analyzed in terms of albumin, total IgG and measles-specific IgG levels (Measles Virus IgG ELISA for CSF Diagnostics, Euroimmun, Germany). The value of CSQrel (relative CSF/serum quotient) ≥ 1.5 was accepted indicative for intrathecal measles antibody synthesis. Seven (63.6%) of the 11 patients' diagnosis were confirmed with the demonstration of elevated CSF/serum indices (CSQrel range: 2.3-36.9; mean: 12.9). Mean age of those seven cases was 12.3 years (age range: 7-21) and four of them were male. The history of patients with high antibody indices indicated that three of four patients who had measles infection had not been vaccinated against measles. These three unvaccinated patients had measles infection at 3rd, 8th and 30th months of age, respectively, and the period of SSPE development were 15, 6 and 4.5 years, respectively. With this letter we would like to emphasize once more that effective measles vaccination is the only way for the prevention of measles and SSPE and the demonstration of increased measles antibody index in simultaneously obtained serum and CSF samples is crucial for the diagnosis of SSPE.
Vu, David M; Kelly, Dominic; Heath, Paul T; McCarthy, Noel D; Pollard, Andrew J; Granoff, Dan M
2006-07-15
Group C meningococcal conjugate-vaccine effectiveness in the United Kingdom declines from ~90% in the first year to 0% between 1 and 4 years after immunization in infants immunized at 2, 3, and 4 months of age and to 61% in toddlers given a single dose. Confidence intervals are wide, and the extent of protection is uncertain. Serum samples were obtained from children 3-5 years of age who were participants in a preschool booster-vaccine trial. Serum bactericidal activity was measured with human complement. Group C anticapsular antibody concentrations were measured by a radioantigen binding assay. Passive protection was analyzed in an infant rat bacteremia model. Serum samples from UK children who had been immunized 2-3 years earlier as infants or toddlers had higher levels of radioantigen binding, bactericidal activity, and passive protection than did historical control serum samples from unimmunized children (P<.05). A higher proportion of children immunized as infants had serum bactericidal activity titers > or =1 : 4 (considered to be protective) than those immunized as toddlers (61% vs. 24%; P<.01), but there were no significant differences in the proportion of serum samples conferring passive protection (50% and 41%, respectively; P=.4). We found no evidence of lower immunity in children immunized as infants than as toddlers. On the basis of serum bactericidal activity and/or passive protection, 40%-50% of both age groups are protected at 2-3 years after immunization, which was significantly greater than in unimmunized historical controls (<5%).
Natsios, Athanasios; Vezakis, Antonios; Kaparos, Georgios; Fragulidis, Georgios; Karakostas, Nikolaos; Kouskouni, Evangelia; Logothetis, Emmanouil; Polydorou, Andreas
2015-01-01
Serum and bile tumor markers are under intense scrutiny for the diagnosis of malignant disease. The purpose of our study was to report the usefulness of serum and bile tumor markers for the discrimination between benign and malignant pancreatobiliary diseases. Between March 2010 and May 2013, 95 patients with obstructive jaundice or history of biliary obstruction, were included in the study. During ERCP, bile samples were obtained for measurement of tumor markers CEA, CA19- 9, CA125, CA72-4 and CA242. Serum samples were taken before ERCP for the same measurements. The patients were divided into two groups: patients with malignant disease and patients with benign disease. Serum tumor marker levels were significantly higher in patients with malignant disease. Serum CA242 and CA19-9 exhibited the highest diagnostic accuracy (76.8% and 73.7%, respectively). CA125 and CA72-4 levels in bile samples were significantly higher in patients with malignant disease. Bile CA125, CEA and CA72-4 achieved the best diagnostic accuracy (69, 65 and 65), respectively). The combined detection of CA19-9, CA242 in serum and CA125, CA72-4 in bile along with total bilirubin levels, showed the best diagnostic accuracy (81%). Serum and bile tumor markers, when studied alone, lack the diagnostic yield to discriminate benign from malignant pancreatobiliary diseases. In cases of diagnostic dilemmas the combination of serum and bile markers might be helpful.
Yang, Qian; Manicke, Nicholas E.; Wang, He; Petucci, Christopher; Cooks, R. Graham
2013-01-01
A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 μL of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R2>0.95) and reproducibility (RSD ~10 %) were achieved in the concentration ranges from 100 nM to 5 μM for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests. PMID:22760507
Partition of environmental chemicals between maternal and fetal blood and tissues.
Needham, Larry L; Grandjean, Philippe; Heinzow, Birger; Jørgensen, Poul J; Nielsen, Flemming; Patterson, Donald G; Sjödin, Andreas; Turner, Wayman E; Weihe, Pal
2011-02-01
Passage of environmental chemicals across the placenta has important toxicological consequences, as well as for choosing samples for analysis and for interpreting the results. To obtain systematic data, we collected in 2000 maternal and cord blood, cord tissue, placenta, and milk in connection with births in the Faroe Islands, where exposures to marine contaminants is increased. In 15 sample sets, we measured a total of 87 environmental chemicals, almost all of which were detected both in maternal and fetal tissues. The maternal serum lipid-based concentrations of organohalogen compounds averaged 1.7 times those of cord serum, 2.8 times those of cord tissue and placenta, and 0.7 those of milk. For organohalogen compounds detectable in all matrices, a high degree of correlation between concentrations in maternal serum and the other tissues investigated was generally observed (r(2) > 0.5). Greater degree of chlorination resulted in lower transfer from maternal serum into milk. Concentrations of pentachlorbenzene, γ-hexachlorocyclohexane, and several polychlorinated biphenyl congeners with low chlorination were higher in fetal samples and showed poor correlation with maternal levels. Perfluorinated compounds occurred in lower concentrations in cord serum than in maternal serum. Cadmium, lead, mercury, and selenium were all detected in fetal samples, but only mercury showed close correlations among concentrations in different matrices. Although the environmental chemicals examined pass through the placenta and are excreted into milk, partitions between maternal and fetal samples are not uniform.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-07
To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.
Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases
Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr
2014-01-01
AIM: To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). METHODS: Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn’s disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student’s t test (α = 0.05). RESULTS: The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value < 0.001 for serum and 0.003 for urine). The metabolites that were found to be the strongest biomarkers included in this case: leucine, isoleucine, 3-hydroxybutyric acid, N-acetylated compounds, acetoacetate, glycine, phenylalanine and lactate (increased in serum), creatine, dimethyl sulfone, histidine, choline and its derivatives (decreased in serum), as well as citrate, hippurate, trigonelline, taurine, succinate and 2-hydroxyisobutyrate (decreased in urine). No clear separation in PLS-DA models was found between CD and UC patients based on the analysis of serum and urine samples, although one metabolite (formate) in univariate statistical analysis was significantly lower in serum of patients with active CD, and two metabolites (alanine and N-acetylated compounds) were significantly higher in serum of patients with CD when comparing jointly patients in the remission and active phase of the diseases. Contrary to the results obtained from the serum samples, the analysis of urine samples allowed to distinguish patients with IBD in remission from healthy control subjects. The metabolites of importance included in this case up-regulated acetoacetate and down-regulated citrate, hippurate, taurine, succinate, glycine, alanine and formate. CONCLUSION: NMR-based metabolomic fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission. PMID:24415869
NASA Astrophysics Data System (ADS)
Zhang, Yanjiao; Lai, Xiaoping; Zeng, Qiuyao; Li, Linfang; Lin, Lin; Li, Shaoxin; Liu, Zhiming; Su, Chengkang; Qi, Minni; Guo, Zhouyi
2018-03-01
This study aims to classify low-grade and high-grade bladder cancer (BC) patients using serum surface-enhanced Raman scattering (SERS) spectra and support vector machine (SVM) algorithms. Serum SERS spectra are acquired from 88 serum samples with silver nanoparticles as the SERS-active substrate. Diagnostic accuracies of 96.4% and 95.4% are obtained when differentiating the serum SERS spectra of all BC patients versus normal subjects and low-grade versus high-grade BC patients, respectively, with optimal SVM classifier models. This study demonstrates that the serum SERS technique combined with SVM has great potential to noninvasively detect and classify high-grade and low-grade BC patients.
Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav
2009-05-01
Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.
Early Prediction of Lupus Nephritis Using Advanced Proteomics
2012-06-01
urine samples for research were obtained, and information on the following laboratory measures was collected: BUN ( urea ), serum creatinine, serum... urine chemistry), medications and other clinical outcomes (overall disease activity, renal and overall damage). Specific Aim 2: Advanced proteomic...measured by the external standards. We concluded that serial measurements of plasma and urine NGAL may be valuable in predicting impending worsening of
Culzoni, María J; Aucelio, Ricardo Q; Escandar, Graciela M
2012-08-31
Based on green analytical chemistry principles, an efficient approach was applied for the simultaneous determination of galantamine, a widely used cholinesterase inhibitor for the treatment of Alzheimer's disease, and its major metabolites in serum samples. After a simple serum deproteinization step, second-order data were rapidly obtained (less than 6 min) with a chromatographic system operating in the isocratic regime using ammonium acetate/acetonitrile (94:6) as mobile phase. Detection was made with a fast-scanning spectrofluorimeter, which allowed the efficient collection of data to obtain matrices of fluorescence intensity as a function of retention time and emission wavelength. Successful resolution was achieved in the presence of matrix interferences in serum samples using multivariate curve resolution-alternating least-squares (MCR-ALS). The developed approach allows the quantification of the analytes at levels found in treated patients, without the need of applying either preconcentration or extraction steps. Limits of detection in the range between 8 and 11 ng mL(-1), relative prediction errors from 7 to 12% and coefficients of variation from 4 to 7% were achieved. Copyright © 2012 Elsevier B.V. All rights reserved.
Colon Reference Set Application: Mary Disis - University of Washington (2008) — EDRN Public Portal
The proposed study aims to validate the diagnostic value of a panel of serum antibodies for the early detection of colorectal cancer (CRC). We have developed a serum antibody based assay that shows promise in discriminating sera from CRC patients from healthy donors. We have evaluated two separate sample sets of sera that were available either commercially or were comprised of left over samples from previous studies by our group. Both sample sets showed concordance in discriminatory power. We have not been able to identify investigators with a larger, well defined sample set of early stage colon cancer sera and request assistance from the EDRN in obtaining such samples to help assess the potential diagnostic value of our autoantibody panel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kreja, L.; Baltschukat, K.; Nothdurft, W.
1988-08-01
Erythroid burst-forming units (BFU-E) from canine bone marrow and peripheral blood could be grown in methylcellulose in the presence of an appropriate batch of fetal calf serum (FCS), transferrin, and erythropoietin (Epo). However, improved colony formation (size and number of bursts) was obtained when serum from total body irradiated dogs was present in the culture. This serum, obtained from dogs at day 9 after total body irradiation with a dose of 3.9 Gy, reduced markedly the Epo requirement of BFU-E. Furthermore, it allowed the omission of FCS from the culture medium if cholesterol and bovine serum albumin (BSA) were usedmore » as FCS substitutes. BFU-E concentrations were found to be rather different in the peripheral blood and in bone marrow samples from different sites (i.e., iliac crest, sternum, and humerus) of normal beagles. The studies further show that canine bone marrow BFU-E can be cryopreserved in liquid nitrogen.« less
The effect of short duration transportation on serum cortisol response in alpacas (Llama pacos).
Anderson, D E; Grubb, T; Silveira, F
1999-03-01
This research project evaluated the changes in serum cortisol in six male and six female alpacas in response to transportation of short duration. All alpacas were subjected to trailer transportation for 30 min. Serum samples were obtained prior to transportation, immediately after transportation, and after a 4-h recovery period. Heart rate was recorded at each time interval and observations of individual behavioural characteristics were recorded. Data were analysed using analysis of variance. Heart rate was not significantly changed by transportation stress. Serum cortisol concentration was significantly higher after transportation, but head returned to baseline concentration after the 4-h recovery period. Behavioural characteristics were not associated with changes in serum cortisol concentration.
Azimi, Mina; Nikanfar, Masoud; Khakikhatibi, Fatemeh; Rahbarghazi, Reza; Nourazarian, Seyed Manuchehr; Biray Avci, Cigir; Nourazarian, Alireza
2017-09-01
According to evidence, Alzheimer's disease is known as one of the most serious neurodegenerative diseases, for which hypertension has been observed to be a key risk factor. Therefore, this study aims to examine the relationship between the PIN1 and eNOS genes expression, as well as serum levels and hypertension in Alzheimer's disease sufferers. Blood samples were obtained from subjects who were divided into four groups: the control group, normotensive Alzheimer's patients, the Alzheimer's sufferers group with hypertension, and the healthy group with only hypertension, considering the inhibition of confounding factors. Thereafter, eNOS and PIN1 genes expression along with serum levels were studied. Based on the obtained results, a statistically significant correlation didn't exist between serum level of PIN1 and the systolic and diastolic blood pressure, between serum level of eNOS and diastolic blood pressure in the norm tension Alzheimer's disease patients, between serum levels of PIN1, eNOS and systolic blood pressure, and between serum eNOS and systolic and diastolic blood pressure in the patients with hypertension (p<0.05). According to the results obtained from this study, measuring the serum levels of eNOS and Pin1 may contribute to the prognosis, prevention, and monitoring of hypertension and also to the reduction of death rates from cardiovascular diseases in Alzheimer's disease. Copyright © 2017 Elsevier Ltd. All rights reserved.
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Wei-Jun; Leach, Robin J.; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srivastava, Sudhir; Rodland, Karin D.; Camp, David G.
2012-01-01
Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. PMID:22846433
Decreased measles antibody response after measles-mumps-rubella vaccine in infants with colds.
Krober, M S; Stracener, C E; Bass, J W
1991-04-24
We examined the possibility that the common cold or afebrile upper respiratory tract infection might interfere with successful immunization in children who receive standard measles-mumps-rubella vaccine. Infants 15 to 18 months of age presenting at our well-child clinics for routine examination and immunizations were divided into two groups. Those infants with a history and physical findings of upper respiratory tract infection were compared with healthy control group infants who did not have upper respiratory tract infections, and who did not have a history of upper respiratory tract infection symptoms within the previous month. Both groups were studied for their serologic response to measles-mumps-rubella vaccination. Prevaccination serum samples were obtained prior to vaccine administration and postvaccination serum samples were obtained 6 to 8 weeks later. Measles antibody was measured in these serum samples by an indirect fluorescein-tagged antibody test. Ten (21%) of 47 infants with colds failed to develop measles antibody, while only one (2%) of 51 well infants failed to develop antibody. We conclude that infants with colds have a significant seroconversion failure rate associated with measles vaccine administration and that this may be the cause of some primary measles vaccine failures.
1976-01-01
Serum samples obtained from two groups within the College of Veterinary Medicine, Iowa State University, were examined for Toxoplasma gondii antibodies. Serum samples from 65 (26.0%) of the 250 persons examined yielded a titer of 1:16 or greater by the indirect fluorescent antibody test. A prevalence of 33.3% was obtained for 108 Veterinary Medical Research Institute (VMRI) personnel. Fof 142 veterinary students, the reactive rate was 20.4%. There was a marked difference of results within the student group--the reactive rate of 31.0% of 58 members of the class of 1975 was significantly higher (p less than 0.05) than the 13.1% for 84 members of the class of 1976. Studies on multiple serum samples were carried out on 55 VMRI personnel; 17 showed a change in serologic reactivity but only 5 had titers of 1:64 or greater. No definitive relationships could be determined between the epidemiologic characteristics examined and the presence of T. gondii antibodies. Characteristics examined included age, sex, primary residency, food habits (eating of rare beef and smoked pork products), and extent of animal contact. Images p526-a PMID:825918
Stevens, Servi J. C.; Pronk, Inge; Middeldorp, Jaap M.
2001-01-01
Epstein-Barr virus (EBV) DNA load monitoring in peripheral blood has been shown to be a useful tool for the diagnosis of aberrant EBV infections. In the present study we compared the relative diagnostic values of EBV DNA load monitoring in unfractionated whole blood and simultaneously obtained serum or plasma samples from Burkitt's lymphoma (BL) patients, transplant recipients, human immunodeficiency virus (HIV)-infected individuals, and infectious mononucleosis (IM) patients by a quantitative competitive PCR (Q-PCR). The EBV DNA load in BL patients was mainly situated in the cellular blood compartment (up to 4.5 × 106 copies/ml). EBV DNA loads in unfractionated whole blood and parallel serum samples showed no correlation. In transplant recipients, IM patients, and HIV-infected patients, the EBV burden in the circulation was almost exclusively restricted to the cellular blood compartment, because serum or plasma samples from these patients yielded negative results by Q-PCR, despite high viral loads in corresponding whole-blood samples. A 10-fold more sensitive but qualitative BamHI-W-repeat PCR occasionally revealed the presence of EBV at <2,000 copies of EBV DNA per ml of serum. Spiking of 100 copies of EBV DNA in samples with negative Q-PCR results excluded the presence of inhibitory factors in serum or plasma that influenced the Q-PCR result. Serum samples from all populations were often positive for β-globin DNA, indicating cell damage in vivo or during serum preparation. We conclude that serum is an undesirable clinical specimen for EBV DNA load monitoring because it omits the presence of cell-associated virus and uncontrolled cell lysis may give irreproducible results or overestimation of the DNA load. Unfractionated whole blood is strongly preferred since it combines all blood compartments that may harbor EBV and it best reflects the absolute viral burden in the patient's circulation. PMID:11283029
Van Emon, Jeanette M; Reed, Allan W; Yike, Iwona; Vesper, Stephen J
2003-06-01
The goal of this research was to develop a measurable indicator of human exposure to Stachyborys chartarum. Antibodies were produced against the hemolytic agent stachylysin obtained from the mold S. chartarum. These antibodies were used to develop two enzyme-linked immunosorbent assay methods for the analysis of stachylysin in human and rat sera and environmental samples. Stachylysin was measured in rat pups that received nasal instillations of S. chartarum conidia but not in control rat serum. Stachylysin in the serum of five human adults exposed to S. chartarum in water-damaged environments was 371 ng/mL but none was detected in the control serum. Stachylysin was also quantified in spore, wallboard, mycelial, and dust samples. The measurement of stachylysin may be a useful indicator in assessing human exposure to S. chartarum and in determining the presence of this indoor mold.
Serum and urine chromium as indices of chromium status in tannery workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Randall, J.A.; Gibson, R.S.
Serum and urinary Cr levels of a selected group of men exposed to CrIII in four Southern Ontario tanneries were compared with those of men not exposed to Cr. Fasted blood samples were obtained from 72 tannery workers (TW; mean age +/- SD = 36 +/- 12 years) and from 52 controls (CS; mean age +/- SD = 41 +/- 13 years). Serum Cr levels as determined by graphite furnace atomic absorption spectrophotometry were significantly higher (P = 0.0001) for TW (median 0.49 ng/ml, range 0.37-0.81) than for CS (median 0.15 ng/ml, range 0.12-0.20). Urine samples were collected from 49more » TW and 43 CS on a Friday pm and from 42 TW on a Monday am. Urinary creatine (Cre) was determined by the Jaffe reaction. For Friday samples, the median urinary Cr/Cre ratio was significantly higher (P = 0.0001) for TW (median 0.83 ng/mg, range 0.48-1.82) than for CS (median 0.18 ng/mg, range 0.13-0.26). For TW, Cr/Cre was correlated with serum Cr (r = 0.72, P = 0.0001). Neither urinary Cr/Cre nor serum Cr was correlated with length of employment in the tanning industry. There were significant differences in serum Cr levels and urinary Cr/Cre ratios among TW employed in different areas of the tanneries. For TW, the median urinary Cr/Cre ratio for Monday morning samples was significantly lower than for Friday afternoon samples (P = 0.03). These data indicate that CrIII is absorbed and that serum and urine Cr in tannery workers may be indices of Cr exposure and status.« less
Serum and urine chromium as indices of chromium status in tannery workers.
Randall, J A; Gibson, R S
1987-05-01
Serum and urinary Cr levels of a selected group of men exposed to CrIII in four Southern Ontario tanneries were compared with those of men not exposed to Cr. Fasted blood samples were obtained from 72 tannery workers (TW; mean age +/- SD = 36 +/- 12 years) and from 52 controls (CS; mean age +/- SD = 41 +/- 13 years). Serum Cr levels as determined by graphite furnace atomic absorption spectrophotometry were significantly higher (P = 0.0001) for TW (median 0.49 ng/ml, range 0.37-0.81) than for CS (median 0.15 ng/ml, range 0.12-0.20). Urine samples were collected from 49 TW and 43 CS on a Friday pm and from 42 TW on a Monday am. Urinary creatine (Cre) was determined by the Jaffe reaction. For Friday samples, the median urinary Cr/Cre ratio was significantly higher (P = 0.0001) for TW (median 0.83 ng/mg, range 0.48-1.82) than for CS (median 0.18 ng/mg, range 0.13-0.26). For TW, Cr/Cre was correlated with serum Cr (r = 0.72, P = 0.0001). Neither urinary Cr/Cre nor serum Cr was correlated with length of employment in the tanning industry. There were significant differences in serum Cr levels and urinary Cr/Cre ratios among TW employed in different areas of the tanneries. For TW, the median urinary Cr/Cre ratio for Monday morning samples was significantly lower than for Friday afternoon samples (P = 0.03). These data indicate that CrIII is absorbed and that serum and urine Cr in tannery workers may be indices of Cr exposure and status.
Fast detection of Piscirickettsia salmonis in Salmo salar serum through MALDI-TOF-MS profiling.
Olate, Verónica R; Nachtigall, Fabiane M; Santos, Leonardo S; Soto, Alex; Araya, Macarena; Oyanedel, Sandra; Díaz, Verónica; Marchant, Vanessa; Rios-Momberg, Mauricio
2016-03-01
Piscirickettsia salmonis is a pathogenic bacteria known as the aetiological agent of the salmonid rickettsial syndrome and causes a high mortality in farmed salmonid fishes. Detection of P. salmonis in farmed fishes is based mainly on molecular biology and immunohistochemistry techniques. These techniques are in most of the cases expensive and time consuming. In the search of new alternatives to detect the presence of P. salmonis in salmonid fishes, this work proposed the use of MALDI-TOF-MS to compare serum protein profiles from Salmo salar fish, including experimentally infected and non-infected fishes using principal component analysis (PCA). Samples were obtained from a controlled bioassay where S. salar was challenged with P. salmonis in a cohabitation model and classified according to the presence or absence of the bacteria by real time PCR analysis. MALDI spectra of the fish serum samples showed differences in its serum protein composition. These differences were corroborated with PCA analysis. The results demonstrated that the use of both MALDI-TOF-MS and PCA represents a useful tool to discriminate the fish status through the analysis of salmonid serum samples. Copyright © 2016 John Wiley & Sons, Ltd.
Yamane, Itsuro; Ishizeki, Sayoko; Yamazaki, Hisanori
2015-05-01
Pseudorabies virus (PRV) is endemic in some regions of Japan. We investigated the effects of PRV infection status on herd productivity. Serum samples were obtained from 48 swine herds in Japan. Within each herd, three serum samples were obtained from growing pigs at four different ages, as well as from sows in low and high parity groups. Sera were tested for antibodies against wild-type PRV via competitive ELISA. Herds were classified into PRV positive and negative groups based on serological results. Herds infected with PRV exhibited postweaning mortalities (6.84%) that were significantly (P=0.0018) higher than those in unaffected herds (4.73%). Because of the reduced productivity in PRV positive herds, the current PRV eradication program must be strengthened.
Henriksen, Louise T; Nersting, Jacob; Raja, Raheel A; Frandsen, Thomas L; Rosthøj, Steen; Schrøder, Henrik; Albertsen, Birgitte K
2014-07-01
L-asparaginase is an important drug in the treatment of childhood acute lymphoblastic leukaemia (ALL). Cerebrospinal fluid (CSF) asparagine depletion is considered a marker of asparaginase effect in the central nervous system (CNS) and may play a role in CNS-directed anti-leukaemia therapy. The objective of this study was to describe CSF asparagine depletion during 30 weeks of pegylated asparaginase therapy, 1000 iu/m(2) i.m. every second week, and to correlate CSF asparagine concentration with serum L-asparaginase enzyme activity. Danish children (1-17 years) with ALL, treated according to the Nordic Society of Paediatric Haematology and Oncology ALL2008 protocol, standard and intermediate risk, were included. CSF samples were obtained throughout L-asparaginase treatment at every scheduled lumbar puncture. A total of 128 samples from 31 patients were available for analysis. Median CSF asparagine concentration decreased from a pre-treatment level of 5·3 μmol/l to median levels ≤1·5 μmol/l. However, only 4/31 patients (five samples) had CSF asparagine concentrations below the limit of detection (0·1 μmol/l). In 11 patients, 24 paired same day serum and CSF samples were obtained. A decrease in CSF asparagine corresponded to serum enzyme activities above 50 iu/l. Higher serum enzyme activities were not followed by more extensive depletion. In conclusion, pegylated asparaginase 1000 iu/m(2) i.m. every second week effectively reduced CSF asparagine levels. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Farnoudian-Habibi, Amir; Massoumi, Bakhshali; Jaymand, Mehdi
2016-11-01
A novel and efficient strategy for the simultaneous determination of two tricyclic antidepressant (TCA) drugs [amitriptyline (AT), and its main metabolite (nortriptyline; NT)] via a combination of magnetic solid phase extraction (MSPE), and spectrophotometric techniques in serum is suggested. For this purpose, the imidazolium ionic liquid (Imz)-modified Fe3O4@SiO2 nanoparticles (Fe3O4@SiO2-Imz) was employed as an adsorbent for the MSPE. Preconcentration (loading-desorption) studies were performed under optimized conditions including pH, adsorbent amount, contact time, eluent volume, and desorption time. Afterward, determination of each drug was carried out by specific strategy. Acetaldehyde (AC), and 2,3,5,6-tetrachloro-1,4-benzoquinone (chloranil; CL) were used as chemical reagents for reaction with NT, while AT did not react with these reagents. This method is based on the condensation reaction between secondary amine group of NT and AC to afford an enamine, and subsequently reaction with CL to produce a chlorinated quinone-substituted enamine. The final product exhibited maximum absorption at 556 nm, while the AT was determined at 240 nm. The limits of detections (LODs) for NT and AT in serum sample were obtained as 0.19 and 0.90 ng mL- 1, respectively. The limits of quantifications (LOQs) were obtained to be 0.63 and 2.93 ng mL- 1 for NT and AT, respectively. A linear range was obtained to be 1 to 5 ng mL- 1. Results indicated that the suggested method is applicable for simultaneous determination of NT and AT in serum samples.
Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao
2017-11-27
Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.
Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen
2016-07-01
Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.
Protein electrophoresis in cranes with presumed insect bite.
Hartup, Barry K; Schroeder, Carrie A
2006-06-01
Serum protein electrophoresis (SPE) has emerged as a potentially valuable diagnostic tool in avian medicine; yet, there is limited information regarding SPE in cranes. Since 2000, 20 cases of unilateral periocular or facial soft tissue swelling, blepharitis, feather loss, and ocular or nasal discharge attributed to insect bite hypersensitivity were observed in cranes from a captive breeding center. SPE may be useful for evaluating these lesions. The aim of this study was to characterize the inflammatory response in cranes with hypersensitivity reactions using SPE. Serum samples from 7 cranes diagnosed with hypersensitivity reactions were submitted to a diagnostic laboratory for agarose gel electrophoresis. Results were compared to those in control serum samples obtained from the same cranes during routine physical examination, when they were clinically healthy. Total protein and a- and g-globulin concentrations were significantly increased and albumin/globulin ratios were significantly decreased in serum samples from cranes with hypersensitivity lesions compared with control samples. Using SPE, we documented changes in protein fraction concentrations in cranes with clinical signs of hypersensitivity. The increase in alpha- and gamma-globulin concentrations suggested inflammation and antigenic stimulation, consistent with a Type I hypersensitivity reaction.
Tarasidis, C G; Garnett, W R; Kline, B J; Pellock, J M
1986-01-01
The influence of storage conditions on the total and free concentration of valproic acid (VPA) was studied in six normal male subjects who ingested 750 mg of VPA (3 X 250 mg Depakene capsules; Abbott Laboratories). Blood samples were collected in various types of Vacutainer tubes (red top, no additives; green top, sodium heparin; blue top, sodium citrate; and purple top, EDTA) 2 h post administration of VPA. Either these samples were centrifuged immediately or stored for various periods of time at room temperature or refrigerated, or the supernate was frozen prior to analysis. Free VPA samples were obtained utilizing the Amicon ultrafiltration system. All VPA samples were analyzed by gas-liquid chromatography. Total VPA concentrations obtained from plasma collected with sodium citrate were lower (p less than 0.05) than either serum or plasma collected with other anticoagulants. There were no differences (p greater than 0.05) in total or free VPA concentrations between samples collected in serum or in plasma collected with heparin or EDTA. Storing samples for 96 h at room temperature did not alter the total VPA concentrations but was found to increase the free fraction of VPA (p less than 0.05). The refrigeration or freezing of the supernate from the blood samples for 7 days did not alter (p greater than 0.05) the total or the free fraction of VPA. The results of this study demonstrate that total and/or free VPA may be collected from either serum or plasma, provided sodium citrate is not used to collect plasma.(ABSTRACT TRUNCATED AT 250 WORDS)
Sajid, Muhammad; Basheer, Chanbasha
2016-07-15
In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Kooshki, A; Samadipour, E; Akbarzadeh, R
2015-01-01
Background:Despite the high levels of inflammation in hemodialysis patients and the effects of diet on systemic inflammation, such as the development of atherosclerosis and cardiovascular disease, few studies have evaluated the relationship of macronutrients and antioxidants intake with serum C-reactive protein (CRP). Therefore, this study assessed the relationship between serum high sensitivity CRP (hs-CRP) with macronutrients and antioxidants intake and serum albumin. Methods:This cross-sectional study used census sampling to select 75 hemodialysis patients (35 men and 40 women) who attended the hemodialysis department of Vaseie Hospital of Sabzevar, Iran. After obtaining the written consent, all the patients were interviewed and dietary data was collected by using a semi-quantitative food frequency questionnaire including 160 food items. Diet analysis was performed with Nutritionist IV. Before being connected to the dialysis machine, 5 cc fasting blood samples were obtained from all participants and serum hs-CRP and albumin levels were measured. All the statistical analyses were conducted with SPSS -for Windows, version 16.0. Results:The patients’ mean body mass index was 20.09 ± 3.27 kg/ m2. The participants’ intake of antioxidants and all macronutrients, except for carbohydrates and proteins, was less than the standard levels. Moreover, the hs-CRP had significant inverse relationships with serum albumin (P=0.0001) and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy (P=0.002) and protein (P=0.0001). Conclusion:Our findings indicated hs-CRP levels of hemodialysis patients to have significant inverse relationships with serum albumin and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy and protein. PMID:28255396
Kooshki, A; Samadipour, E; Akbarzadeh, R
2015-01-01
Background: Despite the high levels of inflammation in hemodialysis patients and the effects of diet on systemic inflammation, such as the development of atherosclerosis and cardiovascular disease, few studies have evaluated the relationship of macronutrients and antioxidants intake with serum C-reactive protein (CRP). Therefore, this study assessed the relationship between serum high sensitivity CRP (hs-CRP) with macronutrients and antioxidants intake and serum albumin. Methods: This cross-sectional study used census sampling to select 75 hemodialysis patients (35 men and 40 women) who attended the hemodialysis department of Vaseie Hospital of Sabzevar, Iran. After obtaining the written consent, all the patients were interviewed and dietary data was collected by using a semi-quantitative food frequency questionnaire including 160 food items. Diet analysis was performed with Nutritionist IV. Before being connected to the dialysis machine, 5 cc fasting blood samples were obtained from all participants and serum hs-CRP and albumin levels were measured. All the statistical analyses were conducted with SPSS -for Windows, version 16.0. Results: The patients' mean body mass index was 20.09 ± 3.27 kg/ m2. The participants' intake of antioxidants and all macronutrients, except for carbohydrates and proteins, was less than the standard levels. Moreover, the hs-CRP had significant inverse relationships with serum albumin (P=0.0001) and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy (P=0.002) and protein (P=0.0001). Conclusion: Our findings indicated hs-CRP levels of hemodialysis patients to have significant inverse relationships with serum albumin and vitamin E and C intakes but was not significant. Also, a significant relationship was observed between hs-CRP levels and the intake of energy and protein.
Zhou, Manshui; McDonald, John F; Fernández, Facundo M
2010-01-01
Metabolomic fingerprinting of bodily fluids can reveal the underlying causes of metabolic disorders associated with many diseases, and has thus been recognized as a potential tool for disease diagnosis and prognosis following therapy. Here we report a rapid approach in which direct analysis in real time (DART) coupled with time-of-flight (TOF) mass spectrometry (MS) and hybrid quadrupole TOF (Q-TOF) MS is used as a means for metabolomic fingerprinting of human serum. In this approach, serum samples are first treated to precipitate proteins, and the volatility of the remaining metabolites increased by derivatization, followed by DART MS analysis. Maximum DART MS performance was obtained by optimizing instrumental parameters such as ionizing gas temperature and flow rate for the analysis of identical aliquots of a healthy human serum samples. These variables were observed to have a significant effect on the overall mass range of the metabolites detected as well as the signal-to-noise ratios in DART mass spectra. Each DART run requires only 1.2 min, during which more than 1500 different spectral features are observed in a time-dependent fashion. A repeatability of 4.1% to 4.5% was obtained for the total ion signal using a manual sampling arm. With the appealing features of high-throughput, lack of memory effects, and simplicity, DART MS has shown potential to become an invaluable tool for metabolomic fingerprinting. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.
Analysis of anhydrous glucose and human serum assisted by Raman spectroscopy
NASA Astrophysics Data System (ADS)
González, Naara; Cerecedo-Núñez, H. H.; Padilla-Sosa, P.; Flores, Aaron; May, Manuel; Basurto, Miguel; Alcántara, Gabriela; Muñiz, Omar
2017-02-01
Raman spectroscopy has been considered like a potentially important clinical tool for real-time diagnosis of disease and evaluation of living tissue, whit the proposal to development noninvasive glucose measurements in a near future, with lower power than other reported studies, in this work are reported experimental tests made with a excitation source of semiconductor laser of 785 nm and 35 mW power. Measurements were made to different glucose concentrations, with variation from 50 mg/dL to 6000 mg/dL. For this, three intervals with different ranges of concentration were analyzed, these tests were put into plastic sampling cells, making incise the beam vertically on sample. In the same way measurements to serum human are reported, for healthy volunteers had 12 hours fasting and non-fasting conditions, with it's corresponding values of glucose taken through a conventional glucometer. Freeze-dried human serum was poured on object-holder, in the case of human serum reconstitute, it was used container in which were previously kept samples. Nine spectra per test were obtained and subsequently average was calculated, the spectra were studied in a range of 500 to 1700 cm-1. This work explores the intensity variation of the bands of glucose in 1065 cm-1 and 1127 cm-1 as a function of glucose concentration. In the obtained results, there observes a behavior with positive slope in both substances, interrelation being observed between the measurements, being promissory for non-invasive measurement.
Influenza A Virus Surveillance Based on Pre-Weaning Piglet Oral Fluid Samples.
Panyasing, Y; Goodell, C; Kittawornrat, A; Wang, C; Levis, I; Desfresne, L; Rauh, R; Gauger, P C; Zhang, J; Lin, X; Azeem, S; Ghorbani-Nezami, S; Yoon, K-J; Zimmerman, J
2016-10-01
Influenza A virus (IAV) surveillance using pre-weaning oral fluid samples from litters of piglets was evaluated in four ˜12 500 sow and IAV-vaccinated, breeding herds. Oral fluid samples were collected from 600 litters and serum samples from their dams at weaning. Litter oral fluid samples were tested for IAV by virus isolation, quantitative reverse transcription-polymerase chain reaction (qRT-PCR), RT-PCR subtyping and sequencing. Commercial nucleoprotein (NP) enzyme-linked immunosorbent assay (ELISA) kits and NP isotype-specific assays (IgM, IgA and IgG) were used to characterize NP antibody in litter oral fluid and sow serum. All litter oral fluid specimens (n = 600) were negative by virus isolation. Twenty-five oral fluid samples (25/600 = 4.2%) were qRT-PCR positive based on screening (Laboratory 1) and confirmatory testing (Laboratory 2). No hemagglutinin (HA) and neuraminidase (NA) gene sequences were obtained, but matrix (M) gene sequences were obtained for all qRT-PCR-positive samples submitted for sequencing (n = 18). Genetic analysis revealed that all M genes sequences were identical (GenBank accession no. KF487544) and belonged to the triple reassortant influenza A virus M gene (TRIG M) previously identified in swine. The proportion of IgM- and IgA-positive samples was significantly higher in sow serum and litter oral fluid samples, respectively (P < 0.01). Consistent with the extensive use of IAV vaccine, no difference was detected in the proportion of IgG- and blocking ELISA-positive sow serum and litter oral fluids. This study supported the use of oral fluid sampling as a means of conducting IAV surveillance in pig populations and demonstrated the inapparent circulation of IAV in piglets. Future work on IAV oral fluid diagnostics should focus on improved procedures for virus isolation, subtyping and sequencing of HA and NA genes. The role of antibody in IAV surveillance remains to be elucidated, but longitudinal assessment of specific antibody has the potential to provide information regarding patterns of infection, vaccination status and herd immunity. © 2014 Blackwell Verlag GmbH.
[Measurement of the status of trace elements in cattle using liver biopsy samples].
Ouweltjes, W; de Zeeuw, A C; Moen, A; Counotte, G H M
2007-02-01
Serum, plasma, or urine samples are usually used for the measurement of the trace elements copper; zinc, iron, selenium, because these samples are easy to obtain; however; these samples are not always appropriate. For example, it is not possible to measure molybdenum, the major antagonist of copper; in blood or urine. Therefore measurement of trace elements in liver tissue is considered the gold standard. For the assessment of selenium the method of choice remains determination of glutathion peroxidase in erythrocytes and for the assessment of magnesium determination of magnesium in urine. We determined the accuracy and repeatability of measuring trace elements in liver biopsies and whole liver homogenates. The levels of trace elements measured were similar in both preparations (92% agreement). Liver biopsy in live animals is a relatively simple procedure but not common in The Netherlands. Reference levels of trace elements, classified as too low, low, adequate, high, and too high, were established on the basis of our research and information in the literature. In a second study we investigated the practical aspects of obtaining liver tissue samples and their use. Samples were collected from cattle on a commercial dairy farm. Liver biopsy provided additional information to that obtained from serum and urine samples. We prepared a biopsy protocol and a test package, which we tested on 14 farms where an imbalance of trace minerals was suspected. Biopsy samples taken from 4 to 6 animals revealed extreme levels of trace elements.
Goudarzi, Nasser; Amirnavaee, Monavar; Arab Chamjangali, Mansour; Farsimadan, Sahar
2017-07-01
An improved microextraction method is proposed on the basis of ultrasound-assisted surfactant-enhanced emulsification and solidification of a floating organic droplet procedure combined with high performance liquid chromatography for the preconcentration and quantification of alprazolam (ALP) and chlordiazepoxide (CHL) present in a number of human serum samples. Several parameters affecting the extraction efficiency were investigated by the Plackett -Burman factorial design as the screening design. Then the response surface methodology based on the Box-Behnken design was used to optimize the effective parameters in the proposed procedure. The limits of detection for the proposed method were found to be 3.0 and 3.1 ng mL-1 for CHL and ALP, respectively. The calibration curves obtained for the method were linear in the ranges of 10.0-3,500.0 and 10.0-3,000.0 ng mL-1 for CHL and ALP, respectively, with a good determination coefficient. The recoveries of the drugs in the spiked human serum samples were above 93.0%. The developed method was successfully applied to the analysis of these studied drugs in human serum samples. The pre-treatment of the serum samples was performed using acetonitrile to remove the proteins. The proposed procedure was an accurate and reliable one for the determination and preconcentration of these drugs in blood samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K
2012-04-30
Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.
Hsieh, Hua-Yi; Li, Li-Hua; Hsu, Ren-Yu; Kao, Wei-Fong; Huang, Ying-Chen; Hsu, Cheng-Chih
2017-06-06
Blood testing for endogenous small metabolites to determine physiological and biochemical states is routine for laboratory analysis. Here we demonstrate that by combining the commercial direct analysis in real time (DART) ion source with an ion trap mass spectrometer, native cholesterol in its free alcohol form is readily detected from a few hundred nanoliters of human serum loaded onto chromatography paper. Deuterium-labeled cholesterol was used as the internal standard to obtain the absolute quantity of the endogenous cholesterol. The amount of the cholesterol measured by this paper-loaded DART mass spectrometry (pDART-MS) is statistically comparable with that obtained by using commercially available fluorometric-enzymatic assay and liquid chromatography/mass spectrometry. Furthermore, sera from 21 participants at three different time points in an ultramarathon were collected to obtain their cholesterol levels. The test requires only very minimal sample preparation, and the concentrations of cholesterol in each sample were acquired within a minute.
Altermann, Wolfgang; Schlaf, Gerald; Rothhoff, Anita; Seliger, Barbara
2007-10-01
Previous studies have suggested that the pre-transplant levels of the soluble CD30 molecule (sCD30) represent a non-invasive tool which can be used as a biomarker for the prediction of kidney allograft rejections. In order to evaluate the feasibility of sCD30 for pre-transplantation monitoring the sera of potential kidney recipients (n = 652) were collected four times in a 3 months interval. Serum from healthy blood donors (n = 203) served as controls. The sCD30 concentrations of all samples were determined using a commercially available ELISA. This strategy allowed the detection of possible variations of individual sCD30 levels over time. Heterogeneous sCD30 concentrations were found in the samples obtained from individual putative kidney transplant recipients when quarterly measured over 1 year. Total 95% of serum samples obtained from healthy controls exhibited sCD30 values <30 U/ml, whereas most recipients displayed higher serum levels (>30 U/ml). Total 524 patients (80.4%) constantly exhibited serum concentrations of <100 U/ml during the period investigated, whereas 109 patients (16.7%) showed variations by exceeding the proposed 'cut off' of 100 U/ml for one to three times. The frequency of samples exhibiting sCD30 values >100 U/ml was significantly lower than that previously reported. The high degree of variation does not allow the stratification of patients into high and low immunological risk groups based on a single sCD30 value > 100 U/ml. Due to the heterogeneity of sCD30 levels during time course and the high values of SD, its implementation as a pre-transplant marker cannot be justified to generate special provisions for the organ allocation to patients with single sCD30 values > 100 U/ml.
Jager, N G L; Rosing, H; Schellens, J H M; Linn, S C; Beijnen, J H
2014-02-01
A sensitive and selective HPLC-MS/MS assay was used to analyze steady-state serum concentrations of tamoxifen, N-desmethyltamoxifen (E)-endoxifen, (Z)-endoxifen, N-desmethyl-4'-hydroxytamoxifen, 4-hydroxytamoxifen, and 4'-hydroxytamoxifen to support therapeutic drug monitoring (TDM) in patients treated with tamoxifen according to standard of care. When the (Z)-endoxifen serum concentration was below the predefined therapeutic threshold concentration of 5.9 ng/mL, the clinician was advised to increase the tamoxifen dose and to collect another serum sample. Paired serum samples from patients at one dose level at different time points during the tamoxifen treatment were used to assess the intra-patient variability. A total of 251 serum samples were analyzed, obtained from 205 patients. Of these patients, 197 used 20 mg tamoxifen per day and 8 patients used 10 mg/day. There was wide variability in tamoxifen and metabolite concentrations within the dosing groups. The threshold concentration for (Z)-endoxifen was reached in one patient (12 %) in the 10 mg group, in 153 patients (78 %) in the 20 mg group, and in 26 (96 %) of the patients who received a dose increase to 30 or 40 mg/day. Dose increase from 20 to 30 or 40 mg per day resulted in a significant increase in the mean serum concentrations of all analytes (p < 0.001). The mean intra-patient variability was between 10 and 20 % for all analytes. These results support the suitability of TDM for optimizing the tamoxifen treatment. It is shown that tamoxifen dose is related to (Z)-endoxifen exposure and increasing this dose leads to a higher serum concentration of tamoxifen and its metabolites. The low intra-patient variability suggests that only one serum sample is needed for TDM, making this a relatively noninvasive way to optimize the patient's treatment.
Serum endocan levels before and after surgery on low-grade gliomas.
Tanriverdi, Taner; Kemerdere, Rahsan; Inal, Berrin B; Yuksel, Odhan; Emre, Humeyra O; Ahmedov, Merdin; Baran, Oguz; Ates, Seda
2017-01-01
Endocan has been shown to be a marker for several cancers and may show degree of malignancy. The aim of this study is to assess serum levels of endocan before and after surgery on low-grade gliomas (LGGs). Endocan was assayed by commercially available enzyme-linked immunosorbent assay (ELISA) kits in a total of 19 patients and 12 controls. Serial serum samples were obtained before and after surgery (1 st day, 1 st week, and 1 st month of surgery). Control samples were collected from cord blood during cesarean section. The results were compared with control brain tissues. Controls showed significantly lower serum endocan levels compared to before and after surgery ( P < 0.05). There is a trend of increase in mean serum levels from before surgery and during the very early period after surgery (during first week); however, in the first month, mean serum levels became lower. Endocan, a vital molecule for angiogenesis, is highly expressed before and after surgery in LGGs, but long-term data is needed. Furthermore, future studies should include high-grade gliomas to discuss whether endocan is associated with recurrence and response to treatment.
Moon, Sung-Sil; Groome, Michelle J; Velasquez, Daniel E; Parashar, Umesh D; Jones, Stephanie; Koen, Antoinette; van Niekerk, Nadia; Jiang, Baoming; Madhi, Shabir A
2016-01-15
Live oral rotavirus (RV) vaccines have shown modest efficacy among children in African countries for reasons that are not completely understood. We examined the possible inhibitory effect of preexisting antirotavirus antibodies on immunogenicity of monovalent RV vaccine (RV1). Mother-infant pairs were enrolled at presentation for their routine immunization visit in Soweto, South Africa, when infants were aged 5-8 weeks. Infant serum samples were obtained before the first and second doses of RV1 and 1 month after the second dose. Maternal serum and breast milk samples were obtained prior to administration of each dose of RV1 to infants. RV-specific immunoglobulin G (IgG), IgA, and neutralizing activity in sera of infants and serum or breast milk samples of mothers were measured using enzyme-linked immunosorbent assays or a microneutralization test. Of the 107 serum pairs from infants who were seronegative for RV IgA at enrollment, we observed a strong positive association between IgG titers in pre-dose 1 sera of infants and mothers and significant negative associations between IgG titers in pre-dose 1 sera of infants and seroconversion to RV1 post-dose 1. Similarly, mothers whose infants' IgA seroconverted after RV1 had significantly lower pre-dose 1 IgG titers in sera than those whose infants did not seroconvert. High levels of preexisting serum IgG, including transplacentally acquired maternal IgG, appeared to have an inhibitory effect on the immunogenicity of RV1 among infants and may, in part, contribute to lower efficacy of RV vaccines in this and other low-income settings. Published by Oxford University Press for the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Fehm, Tanja; Becker, Sven; Duerr-Stoerzer, Silke; Sotlar, Karl; Mueller, Volkmar; Wallwiener, Diethelm; Lane, Nancy; Solomayer, Erich; Uhr, Jonathan
2007-01-01
Introduction At the time when metastatic disease is identified, assessment of human epidermal growth factor receptor (HER)2 status might help to optimize treatment decisions if HER2 status was not determined at first diagnosis and if HER2 positivity has been acquired during disease progression. Within this context, determination of serum HER2 or evaluation of HER2 status in circulating tumor cells (CTCs) may be of clinical relevance because metastatic tissue may be difficult to obtain for analysis as a result of its localization. The aim of this study was therefore to determine the HER2 status in serum and corresponding CTCs in patients with metastatic breast cancer whose primary tumors were HER2 negative or of unknown HER2 status. Methods Blood samples were obtained from 77 metastatic breast cancer patients with negative (n = 44) or unknown (n = 33) HER2 status. Serum HER2 was determined using a commercial HER2/neu ELISA kit. CTCs were detected by slide-based assay using immunomagnetic enrichment and characterized by phenotyping and genotyping. Alternatively, a commercial kit, based on RT-PCR, was used to detect and characterize CTCs. Results Twenty out of 77 patients with metastatic disease had elevated serum levels of HER2. Blood samples could be analyzed for the presence of CTCs in 67 patients. Eight out of 21 patients with detectable CTCs exhibited HER2 amplification. Twenty-three out of 77 patients were HER2 positive using at least one method. Concordance between HER2 status of CTCs and serum HER2 was observed in 15 of 21 patients (71%). In six patients conflicting results were obtained. Three patients with elevated serum HER2 status had HER2-negative CTCs, whereas three patients with HER2-positive CTCs had normal serum HER2 levels. Conclusion A subgroup of patients with initially negative or unknown HER2 status can have elevated serum HER2 levels and/or HER2-positive CTCs at the time of development of metastatic disease. Although only a small number of patients were studied, our observations are of clinical relevance because, currently, these patients do not have access to HER2-targeted therapy. PMID:17963511
Bertaso, Anna; Sorio, Daniela; Vandoros, Anthula; De Palo, Elio F; Bortolotti, Federica; Tagliaro, Franco
2016-10-01
Continued progress in chronic alcohol abuse investigation requires the development of less invasive procedures for screening purposes. The application of finger-prick and related dried blood spots (fpDBS) for carbohydrate deficient transferrin (CDT) detection appears suitable for this aim. Therefore, the goal of this project was to develop a screening method for CDT using fpDBS with CZE analysis. Blood samples prepared by finger-prick were placed on DBS cards and left to air dry; each dried fpDBS disc was shredded into small pieces and suspended in acid solution (60 μL of HCl 120 mmol/L). After centrifugation (10 min at 1500 × g), the collected sample was adjusted to pH 3.5. After an overnight incubation, the pH was neutralised and an iron rich solution was added. After 1 h, CZE analysis was carried out. A group of 47 individuals was studied. Parallel serum samples were collected from each investigated subject and the %CDT for each sample was measured using HPLC and CZE techniques. The fpDBS transferrin sialo isoform electropherograms were similar to those obtained with serum. Moreover, fpDBS CZE CDT percentage levels demonstrated significant statistical correlation with those obtained from serum for both HPLC and CZE %CDT (p < 0.01; r 2 = 0.8913 and 0.8976, respectively), with %CDT from 0.8 to 13.7% for fpDBS and from 0.7 to 12.7% for serum. The newly developed fpDBS procedure for CDT analysis provides a simple and inexpensive tool for use in population screening. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Penetration of Clindamycin into Decubitus Ulcers
Berger, Stephen A.; Barza, Michael; Haher, Jane; McFarland, James J.; Louie, Samuel; Kane, Anne
1978-01-01
Forty tissue samples, primarily of skin and bone, were obtained from 29 patients undergoing excision of decubitus ulcers after intravenous injection of 600 mg of clindamycin. Antibiotic concentrations exceeded 2.5 μg/g in 80% of the samples. In 50% of the instances, tissue levels were greater than those simultaneously present in the serum. PMID:708028
Dhaliwal, G S; Murray, R D; Dobson, H; Montgomery, J; Ellis, W A
1996-03-01
Samples of cervico-vaginal mucus from 163 bulling cows (group 1) and post calving discharges from 59 newly calved cows (group 2) in five dairy herds naturally infected with Leptospira interrogans serovar hardjo were examined for the presence of antigen and IgG and IgA antibodies by using two ELISA systems which were protein or carbohydrate based. Corresponding serum samples were examined for systemic immune responses by using a microscopic agglutination test (MAT) and IgG-ELISA tests. Antigen was detected by direct immunofluorescence in six of the 163 samples of cervico-vaginal mucus. Both IgG and IgA antibodies were detected by ELISA in the genital discharges with a prevalence much higher than that obtained by the MAT but lower than that observed with the serum IgG-ELISA. Combining both groups, none of the MAT-positive cattle was negative by serum-ELISA. By using the protein or carbohydrate fraction serum IgG-ELISA assays, respectively, 29 or 41 per cent of the MAT-negative cows were positive at a titre of at least 1:40. Similarly, eight or 23 samples (10 or 27 per cent) had titres of at least 1:20 in the genital discharge ELISA for IgG and IgA antibodies, respectively. The serum IgG-ELISA was the most efficient in detecting hardjo antibodies, but in group 2 the IgG- and IgA-ELISA of the post calving discharge proved to be equally effective.
Phospholipase A2 as a point of care alternative to serum amylase and pancreatic lipase
NASA Astrophysics Data System (ADS)
Liu, Nathan J.; Chapman, Robert; Lin, Yiyang; Bentham, Andrew; Tyreman, Matthew; Philips, Natalie; Khan, Shahid A.; Stevens, Molly M.
2016-06-01
Acute pancreatitis is a relatively common and potentially fatal condition, but the presenting symptoms are non-specific and diagnosis relies largely on the measurement of amylase activity by the hospital clinical laboratory. In this work we develop a point of care test for pancreatitis measuring concentration of secretory phospholipase A2 group IB (sPLA2-IB). Novel antibodies for sPLA2-IB were raised and used to design an ELISA and a lateral flow device (LFD) for the point of care measurement of sPLA2-IB concentration, which was compared to pancreatic amylase activity, lipase activity, and sPLA2-IB activity in 153 serum samples. 98 of these samples were obtained from the pathology unit of a major hospital and classified retrospectively according to presence or absence of pancreatitis, and the remaining 55 were obtained from commercial sources to serve as high lipase (n = 20), CA19-9 positive (n = 15), and healthy (n = 20) controls. sPLA2-IB concentration correlated well with the serum activity of both amylase and lipase, and performed at least as well as either markers in the differentiation of pancreatitis from controls.Acute pancreatitis is a relatively common and potentially fatal condition, but the presenting symptoms are non-specific and diagnosis relies largely on the measurement of amylase activity by the hospital clinical laboratory. In this work we develop a point of care test for pancreatitis measuring concentration of secretory phospholipase A2 group IB (sPLA2-IB). Novel antibodies for sPLA2-IB were raised and used to design an ELISA and a lateral flow device (LFD) for the point of care measurement of sPLA2-IB concentration, which was compared to pancreatic amylase activity, lipase activity, and sPLA2-IB activity in 153 serum samples. 98 of these samples were obtained from the pathology unit of a major hospital and classified retrospectively according to presence or absence of pancreatitis, and the remaining 55 were obtained from commercial sources to serve as high lipase (n = 20), CA19-9 positive (n = 15), and healthy (n = 20) controls. sPLA2-IB concentration correlated well with the serum activity of both amylase and lipase, and performed at least as well as either markers in the differentiation of pancreatitis from controls. Electronic supplementary information (ESI) available: Additional characterisation and statistical analysis. See DOI: 10.1039/c6nr03376h
Mochizuki, Mariko; Hayakawa, Noriyuki; Minowa, Fumiko; Saito, Akihiro; Ishioka, Katsumi; Ueda, Fukiko; Okubo, Kimihiro; Tazaki, Hiroyuki
2016-04-01
In this study, iodine and thyroxin (T4) concentrations in the serum of 69 horses were investigated. Higher iodine concentrations were obtained from the horses housed in Chiba Prefecture. In contrast, T4 concentrations of horses at Shizuoka Prefecture were higher than those of horses at Chiba Prefecture. There was a significant correlation (r = 0.643, P < 0.001) between the iodine and T4 concentrations of horses at Saitama and Shizuoka prefectures. Although a significant correlation (r = 0.794, P < 0.001) was also observed in the investigation of all horses at Chiba Prefecture, the distribution area of the data was separated from the data of horses housed in Saitama and Shizuoka prefectures. A higher iodine concentration in the environment is expected in the sampling area at Chiba Prefecture. Thus, it was suggested that the concentrations of iodine in the serum of horses are influenced by geological differences. It was thought that equine serum is a useful sample for monitoring.
Borchardt, Stefan; Staufenbiel, Rudolf
2012-04-15
To evaluate the use of nonesterified fatty acids (NEFA) and β-hydroxybutyrate (BHBA) concentrations in pooled serum samples for herd-based detection of subclinical ketosis (SCK) in dairy cows after calving. Cross-sectional study. 1,100 dairy cows from 110 herds. Blood samples were collected from 10 healthy cows/herd in the first week after parturition. Aliquots of serum were mixed to create a pooled sample. Concentrations of NEFA and BHBA were measured to estimate prevalence of SCK. Pooled sample test results were compared with those obtained for individual samples. Linear regression and receiver-operating characteristic curve analysis were performed; Bland-Altman plots were used to evaluate agreement between methods. Overall prevalence of SCK was 30.7%, 19.3%, and 13.6%, as determined by use of BHBA threshold concentrations of 1,000, 1,200, and 1,400 μmol/L, respectively. Pooled sample concentrations of NEFA and BHBA were significantly correlated (r = 0.98 and 0.97, respectively) with individual sample means and with the number of cows that had NEFA (R(2) range, 0.81 to 0.84) or BHBA (R(2) range, 0.65 to 0.76) concentrations above predefined thresholds. Pooled sample concentrations of NEFA and BHBA were very accurate to highly accurate for herd-based detection of SCK. Analysis of NEFA and BHBA concentrations in pooled serum samples was useful for herd-based detection of SCK. A sample size of 10 cows/herd was deemed adequate for monitoring dairy herds for SCK. Reference criteria specific to pooled samples should be used for this type of herd-based testing.
Serum chemistry of free-ranging white whales (Delphinapterus leucas) in Svalbard.
Tryland, Morten; Thoresen, Stein Istre; Kovacs, Kit M; Lydersen, Christian
2006-06-01
Abnormal physiological conditions and diseases can change the concentrations of enzymes, metabolites, and minerals in the body. Serum chemistry information may thus be indicative of a specific disease; interpretation of such information requires knowledge of serum chemistry reference intervals from a seemingly healthy population of the species. The aim of this study was to obtain serum chemistry reference intervals for a population of white whales. Blood samples were collected from 21 free-ranging white whales (beluga; Delphinapterus leucas). The whales were live-captured in nets during 1996-2001 in Storfjorden, Van Mijenfjorden, and Van Keulenfjorden (Svalbard, Norway). While the whales were briefly physically restrained, blood was collected from the caudal vein into vacuum tubes without anticoagulant. The blood was left to clot for 4-6 hours before serum was obtained by centrifugation. The serum samples were then kept at -20 degrees C until analysis. Enzymes (aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase [ALP], creatine kinase, lactate dehydrogenase [LDH], amylase, lipase), metabolites (urea, creatinine, bilirubin, cholesterol, triglycerides, nonesterified fatty acids, glucose), and minerals (calcium, phosphate, magnesium, sodium, potassium, chloride) were analyzed in an Advia 1650 System (Bayer, Tarrytown, NY, USA). Cortisol was analyzed in an Immulite One system (Diagnostic Products Corporation, Los Angeles, CA, USA). The major blood proteins (albumin and globulins) were separated by gel electrophoresis in a Beckman Paragon electrophoresis system (Beckman Coulter, Inc., Fullerton, CA, USA). Serum values for all analytes were reported as median and range, and reference intervals were calculated as 10-90th percentiles. Activities of ALP and LDH and cortisol concentration were higher, and protein and bilirubin concentrations were lower compared with those previously reported for white whales from Canada; remaining results were strikingly similar in these 2 white whale populations. These data provide valuable serum chemistry reference intervals for future health assessments of white whales in Svalbard and other white whale populations, as well as captive individuals.
Gerloff, B J; Herdt, T H; Wells, W W; Nachreiner, R F; Emery, R S
1986-06-01
Percutaneous liver biopsies and blood samples were obtained from 80 dairy cows in nine Michigan herds over the peripartum period. Thirty-nine cows were fed 17 g of supplemental inositol and 41 were fed a placebo. Liver biopsies were assayed for total myoinositol and triglyceride (TG) concentrations. Blood samples were assayed for serum dextran precipitable cholesterol, nonesterified fatty acids (NEFA), insulin, thyroxine (T4), free (FT4), triiodothyronine (T3) and free T3 (FT3) concentrations. Serum concentrations of insulin and the thyroid hormones decreased near parturition, with lowest concentrations occurring in the immediate postpartum period. Concentrations of T3 correlated well with T4, and the concentrations of free thyroid hormones reflected concentrations of total thyroid hormones. The percentage of hormone in the free fraction remained constant over time. Serum insulin, T3 and T4 were negatively correlated with serum NEFA and liver TG concentrations. Thyroid hormone concentrations were positively correlated with serum dextran precipitable cholesterol concentrations. Inositol supplementation was associated with reduced circulating T3 and FT3 concentrations, but not T4 and FT4 concentrations. Changes in hormone concentrations at parturition and their relationship to liver TG and serum NEFA concentrations were consistent with a metabolic adaptation by the dairy cow to the negative energy balance of early lactation.
Pires, Cherrine K.; Martelli, Patrícia B.; Lima, José L. F. C.; Saraiva, Maria Lúcia M. F. S.
2003-01-01
An automatic flow procedure based on multicommutation dedicated for the determination of glucose in animal blood serum using glucose oxidase with chemiluminescence detection is described. The flow manifold consisted of a set of three-way solenoid valves assembled to implement multicommutation. A microcomputer furnished with an electronic interface and software written in Quick BASIC 4.5 controlled the manifold and performed data acquisition. Glucose oxidase was immobilized on porous silica beads (glass aminopropyl) and packed in a minicolumn (15 × 5 mm). The procedure was based on the enzymatic degradation of glucose, producing hydrogen peroxide, which oxidized luminol in the presence of hexacyanoferrate(III), causing the chemiluminescence. The system was tested by analysing a set of serum animal samples without previous treatment. Results were in agreement with those obtained with the conventional method (LABTEST Kit) at the 95% confidence level. The detection limit and variation coefficient were estimated as 12.0 mg l−1 (99.7% confidence level) and 3.5% (n = 20), respectively. The sampling rate was about 60 determinations h−1 with sample concentrations ranging from 50 to 600 mg l−1 glucose. The consumptions of serum sample, hexacyanoferrate(III) and luminol were 46 μl, 10.0 mg and 0.2 mg/determination, respectively. PMID:18924619
Maudry, Arnaud; Chene, Gautier; Chatelain, Rémi; Patural, Hugues; Bellete, Bahrie; Tisseur, Bernard; Hafid, Jamal; Raberin, Hélène; Beretta, Sophie; Sung, Roger Tran Manh; Belot, Georges; Flori, Pierre
2009-09-01
A comparative study of the Toxoplasma IgG(I) and IgG(II) Access (Access I and II, respectively; Beckman Coulter Inc.), AxSYM Toxo IgG (AxSYM; Abbott Diagnostics), Vidas Toxo IgG (Vidas; bioMerieux, Marcy l'Etoile, France), Immulite Toxo IgG (Immulite; Siemens Healthcare Diagnostics Inc.), and Modular Toxo IgG (Modular; Roche Diagnostics, Basel, Switzerland) tests was done with 406 consecutive serum samples. The Toxo II IgG Western blot (LDBio, Lyon, France) was used as a reference technique in the case of intertechnique discordance. Of the 406 serum samples tested, the results for 35 were discordant by the different techniques. Using the 175 serum samples with positive results, we evaluated the standardization of the titrations obtained (in IU/ml); the medians (second quartiles) obtained were 9.1 IU/ml for the AxSYM test, 21 IU/ml for the Access I test, 25.7 IU/ml for the Access II test, 32 IU/ml for the Vidas test, 34.6 IU/ml for the Immulite test, and 248 IU/ml for the Modular test. For all the immunoassays tested, the following relative sensitivity and specificity values were found: 89.7 to 100% for the Access II test, 89.7 to 99.6% for the Immulite test, 90.2 to 99.6% for the AxSYM test, 91.4 to 99.6% for the Vidas test, 94.8 to 99.6% for the Access I test, and 98.3 to 98.7% for the Modular test. Among the 406 serum samples, we did not find any false-positive values by two different tests for the same serum sample. Except for the Modular test, which prioritized sensitivity, it appears that the positive cutoff values suggested by the pharmaceutical companies are very high (either for economical or for safety reasons). This led to imperfect sensitivity, a large number of unnecessary serological follow-ups of pregnant women, and difficulty in determining the serological status of immunosuppressed individuals.
Joulié, A.; Rousset, E.; Gasqui, P.; Lepetitcolin, E.; Leblond, A.; Sidi-Boumedine, K.
2017-01-01
ABSTRACT The control of Q fever, a zoonotic disease caused by the Coxiella burnetii bacterium, remains a scientific challenge. Domestic ruminants are considered the main reservoir, shedding C. burnetii essentially through parturition products during abortion or birth. Sheep are particularly frequently associated with human outbreaks, but there are insufficient field data to fully understand disease dynamics and to instigate efficient control measures. A longitudinal follow-up study of a naturally infected sheep flock was performed (i) to investigate relationships between seropositivity and bacterial shedding in the vaginal mucus, (ii) to describe the kinetics of antibodies, including responses to vaccination, (iii) to monitor maternal antibodies in ewe lambs, and (iv) to compare serological results for milk and serum samples. For 8 months, we collected blood samples every 3 weeks from 11 aborting and 26 nonaborting dairy ewes, 20 nonaborting suckler ewes, and 9 ewe lambs. Individual milk samples were also obtained from lactating females. All serum and milk samples were tested by enzyme-linked immunosorbent assay (ELISA), whereas vaginal swabs were tested by quantitative PCR. We found that some dairy females did not seroconvert despite shedding C. burnetii in their vaginal mucus. Overall, antibody levels in adult females were found to remain stable over time, with exceptions during the mating and lambing periods. Maternal antibodies decreased during the first month after birth. Interestingly, antibody levels in milk were correlated with those in serum. This study provides valuable field data that will help improve Q fever surveillance and within-flock management measures. IMPORTANCE Field data are necessary to improve the surveillance, diagnosis, and sanitary management of Q fever in livestock. Here, we provide extensive serological data obtained from serum and milk samples from infected and vaccinated ewes belonging to a naturally infected flock of sheep. We show that antibody levels are stable over time and seropositivity and vaginal shedding are not clearly correlated, whereas antibody levels in milk are strongly correlated with those in serum. Accordingly, we find that antibody levels in bulk tank milk are consistent with the variations observed in the serum of dairy females over time. We report the existence of maternal antibody transmission to ewe lambs and we show that the presence of maternal antibodies at birth does not prevent the development of a serological response to vaccination at the age of 4 months. Finally, we report that adult ewes generally seroconvert after vaccination, including during pregnancy. PMID:28455328
Joulié, A; Rousset, E; Gasqui, P; Lepetitcolin, E; Leblond, A; Sidi-Boumedine, K; Jourdain, E
2017-07-01
The control of Q fever, a zoonotic disease caused by the Coxiella burnetii bacterium, remains a scientific challenge. Domestic ruminants are considered the main reservoir, shedding C. burnetii essentially through parturition products during abortion or birth. Sheep are particularly frequently associated with human outbreaks, but there are insufficient field data to fully understand disease dynamics and to instigate efficient control measures. A longitudinal follow-up study of a naturally infected sheep flock was performed (i) to investigate relationships between seropositivity and bacterial shedding in the vaginal mucus, (ii) to describe the kinetics of antibodies, including responses to vaccination, (iii) to monitor maternal antibodies in ewe lambs, and (iv) to compare serological results for milk and serum samples. For 8 months, we collected blood samples every 3 weeks from 11 aborting and 26 nonaborting dairy ewes, 20 nonaborting suckler ewes, and 9 ewe lambs. Individual milk samples were also obtained from lactating females. All serum and milk samples were tested by enzyme-linked immunosorbent assay (ELISA), whereas vaginal swabs were tested by quantitative PCR. We found that some dairy females did not seroconvert despite shedding C. burnetii in their vaginal mucus. Overall, antibody levels in adult females were found to remain stable over time, with exceptions during the mating and lambing periods. Maternal antibodies decreased during the first month after birth. Interestingly, antibody levels in milk were correlated with those in serum. This study provides valuable field data that will help improve Q fever surveillance and within-flock management measures. IMPORTANCE Field data are necessary to improve the surveillance, diagnosis, and sanitary management of Q fever in livestock. Here, we provide extensive serological data obtained from serum and milk samples from infected and vaccinated ewes belonging to a naturally infected flock of sheep. We show that antibody levels are stable over time and seropositivity and vaginal shedding are not clearly correlated, whereas antibody levels in milk are strongly correlated with those in serum. Accordingly, we find that antibody levels in bulk tank milk are consistent with the variations observed in the serum of dairy females over time. We report the existence of maternal antibody transmission to ewe lambs and we show that the presence of maternal antibodies at birth does not prevent the development of a serological response to vaccination at the age of 4 months. Finally, we report that adult ewes generally seroconvert after vaccination, including during pregnancy. Copyright © 2017 American Society for Microbiology.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-09-24
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70-200 mg/dL), revealing high system performance for a wide glycemic state range (45-500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting.
Dengue-yellow fever sera cross-reactivity; challenges for diagnosis.
Houghton-Triviño, Natalia; Montaña, Diana; Castellanos, Jaime
2008-01-01
The Flavivirus genera share epitopes inducing cross-reactive antibodies leading to great difficulty in differentially diagnosing flaviviral infections. This work was aimed at evaluating the complexity of dengue and yellow fever serological differential diagnosis. Dengue antibody capture ELISA and a yellow fever neutralisation test were carried out on 13 serum samples obtained from yellow fever patients, 20 acute serum samples from dengue patients and 19 voluntary serum samples pre- and post-vaccination with YF vaccine. Dengue ELISA revealed IgM reactivity in 46,2 % of yellow fever patients and 42 % of vaccinees. Sixteen out of 20 dengue patients (80 %) had high YF virus neutralisation titres. Such very high cross-reactivity data challenged differential laboratory diagnosis of dengue and yellow fever in areas where both flaviviruses co-circulate. New laboratory strategies are thus needed for improving the tests and providing a specific laboratory diagnosis. Cross-reactivity between Flaviviruses represents a great difficulty for epidemiological surveillance and preventing dengue, both of which demand urgent attention.
Validity and Reliability of Perinatal Biomarkers after Storage as Dry Blood Spots on Paper
Mihalopoulos, Nicole L.; Phillips, Terry M.; Slater, Hillarie; Thomson, J. Anne; Varner, Michael W.; Moyer-Mileur, Laurie J.
2013-01-01
Ojective To validate use of chip-based immunoaffinity capillary electrophoresis on dry blood spot samples (DBSS) to measure obesity-related cytokines. Methods Chip-based immunoaffinity capillary electrophoresis was used to measure adiponectin, leptin and insulin in serum and DBSS in pregnant women, cord blood, and infant heelstick at birth and 6 weeks. Concordance of measurements was determined with Pearson's correlation. Results We report high concordance between results obtained from serum and DBSS with the exception of cord blood specimens. Conclusions Ease of sample collection and storage makes DBSS an optimal method for use in studies involving neonates and young children. PMID:21735507
[Seroepidemiology of cholera in Mexico].
González-Bonilla, C; Valle-Valdez, J G; Núñez-León, A; Moguel-Pech, L; Villanueva-Zamudio, A
1994-01-01
Antibodies against Vibrio cholerae were determined in 2352 serum samples obtained from patients with clinical diagnosis of cholera. Samples from their contacts and from healthy people living in the same communities were also analyzed. Vibriocidal antibodies with titers 1:160 or higher were observed in 25% of the samples. An increase of vibriocidal and antitoxin antibody titers were observed in 56 to 60% of the patients in which paired samples were available, one obtained in the acute phase of the disease and the other in the convalescence, confirming the diagnosis of cholera. Differences in the antibody titers were noticed when comparing the serotype according to the geographic area and the season of the year.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodgen, G.D.; Wilks, J.W.; Vaitukaitis, J.L.
A sensitive and specific radioimmunoassay system for macaque follicle-stimulating hormone (mFSH) was developed utilizing an antiserum (H-31) prepared in a rabbit against purified ovine FSH as the immunogen. Sera from castrated female, adult male, and juvenile rhesus monkeys, as well as urinary extracts from castrated rhesus and bonnet monkeys, were used to demonstrate parallelism with a standard of partially purified monkey pituitary gonadotropins (LER-M-907-D). An extract of baboon pituitary tissue also showed parallelism with the reference standard. A highly purified pituitary extract (WP-X-105-28), containing approximately 75 percent macaque luteinizing hormone (mLH) and 1 percent mFSH, was used to demonstrate themore » specificity of this mFSH assay system. Sera and urinary extracts obtained from hypophysectomized monkeys did not show cross-reactivity in the assay. Macaque chorionic gonadotropin (mCG) did not produce an inhibition curve in the assay, as determined from serum samples and urinary extracts collected from pregnant monkeys at the time of peak mCG secretion. Serum concentrations of mFSH were suppressed in ovariectomized monkeys by the administration of ethinyl estradiol for 3 days, but returned to near pretreatment values by 96 h after the last estradiol administration. The determination of serum mFSH concentrations in daily blood samples obtained from 20 rhesus monkeys throughout ovulatory menstrual cycles revealed a pattern similar to that previously reported for the rhesus monkey and the woman. The peak value of serum mFSH during the menstrual cycle coincided with the midcycle surge of mLH in each case. The gonadotropin peaks were preceded by increasing serum concentrations of estradiol and followed by rises in the serum concentrations of progesterone.« less
Expression of microRNAs of C19MC in Different Histological Types of Testicular Germ Cell Tumour.
Flor, Inga; Spiekermann, Meike; Löning, Thomas; Dieckmann, Klaus-Peter; Belge, Gazanfer; Bullerdiek, Jörn
2016-01-01
Testicular germ cell tumours (TGCTs) are the most common tumours in men aged from 20 to 40 years, with a steadily increasing incidence. This study aimed to characterize the expression of the miRNA cluster C19MC in TGCT and to evaluate the suitability of a C19MC miRNA as a serum biomarker. By quantitative reverse transcription PCR, we measured the expression of miR-517a-3p, miR-519a-3p, and miR-519c 3p in tissue samples of 25 TGCTs and the level of miR-517a-3p in serum samples obtained pre- and postoperatively from the same patients. We detected a significantly higher expression of C19MC miRNAs in non-seminomas than in seminomas and in clinical stages 2 and 3 than in stage 1 in both tissue and serum samples. miRNAs of C19MC are overexpressed in more aggressive types of TGCT, suggesting they contribute to malignancy. Furthermore, they might serve as serum biomarkers for these types of TGCT. Copyright© 2016, International Institute of Anticancer Research (Dr. John G. Delinasios), All rights reserved.
Spencer, Kevin; Cuckle, Howard S
2002-10-01
To assess the within person biological variability of first trimester maternal serum biochemical markers of trisomy 21 across the 10-14 week gestational period. To evaluate whether repeat sampling and testing of free beta-hCG and PAPP-A during this period would result in an improved detection rate. Women presenting at the first trimester OSCAR clinic have blood collected prior to ultrasound dating and nuchal translucency measurement. All samples are analysed for free beta-hCG and PAPP-A before an accurate estimate of gestation is available. In 10% of cases the gestation is prior to the minimum time for NT measurement (11 weeks) and these women are rebooked for a repeat visit to the clinic at the appropriate time. Our fetal database was interrogated to obtain cases in which two maternal blood samples had been collected and analysed in the 10-14 week period. Using data from the marker correlations and statistical modelling, the impact of repeat testing on detection rate for trisomy 21 at a fixed 5% false positive rate, was assessed. 261 pairs of data were available for analysis collected over a 3 year period. The correlation between free beta-hCG in sample 1 and sample 2 was 0.890 and that for PAPP-A was 0.827. The average within person biological variation for free beta-hCG was 21% and 32% for PAPP-A. The increase in detection rate when using both sets of marker data was 3.5% when using serum biochemistry and maternal age, and 1.3% when using nuchal translucency, serum biochemistry and maternal age. Repeat sampling and testing of maternal serum biochemical markers is unlikely to substantially improve first trimester screening performance. Copyright 2002 John Wiley & Sons, Ltd.
Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi
2014-01-20
Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV <1%. A certified reference material (CRM) of lipids in frozen human serum was used to verify the accuracy of the measurement. The obtained values for both triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation <0.4% from the certified values. The relative expanded uncertainties were also comparable with the uncertainties associated with the certified values of the CRM. The validated procedure was used in an External Quality Assessment (EQA) Program organized by our laboratory to establish the assigned values for triglycerides and total glycerides.
Serum and saliva magnesium in postmenopausal women with xerostomia.
Agha-Hosseini, F; Mirzaii-Dizgah, I
2012-10-01
The aim of this study was to investigate serum, stimulated and unstimulated salivary magnesium in postmenopausal women with xerostomia. A case-control study was carried out on 60 selected postmenopausal women aged 41-77 years with or without xerostomia (30 as cases with xerostomia and 30 as controls without xerostomia), conducted at the Clinic of Oral Medicine, Tehran University of Medical Sciences. Unstimulated and paraffin-stimulated saliva samples were obtained by expectoration. Magnesium concentration was determined by the spectrophotometer method. Statistical analysis was carried out using Student's t-test. The mean serum concentration, but not stimulated and unstimulated whole saliva magnesium concentrations, was significantly higher in the cases than in the controls. Serum magnesium level appears to be associated with xerostomia in menopause.
A bacterial engineered glycoprotein as a novel antigen for diagnosis of bovine brucellosis.
Ciocchini, Andrés E; Serantes, Diego A Rey; Melli, Luciano J; Guidolin, Leticia S; Iwashkiw, Jeremy A; Elena, Sebastián; Franco, Cristina; Nicola, Ana M; Feldman, Mario F; Comerci, Diego J; Ugalde, Juan E
2014-08-27
Brucellosis is a highly contagious zoonosis that affects livestock and human beings. Laboratory diagnosis of bovine brucellosis mainly relies on serological diagnosis using serum and/or milk samples. Although there are several serological tests with different diagnostic performance and capacity to differentiate vaccinated from infected animals, there is still no standardized reference antigen for the disease. Here we validate the first recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of bovine brucellosis. This antigen can be produced in homogeneous batches without the need of culturing pathogenic brucellae; all characteristics that make it appropriate for standardization. An indirect immunoassay based on the detection of anti O-polysaccharide IgG antibodies in bovine samples was developed coupling OAg-AcrA to magnetic beads or ELISA plates. As a proof of concept and to validate the antigen, we analyzed serum, whole blood and milk samples obtained from non-infected, experimentally infected and vaccinated animals included in a vaccination/infection trial performed in our laboratory as well as more than 1000 serum and milk samples obtained from naturally infected and S19-vaccinated animals from Argentina. Our results demonstrate that OAg-AcrA-based assays are highly accurate for diagnosis of bovine brucellosis, even in vaccinated herds, using different types of samples and in different platforms. We propose this novel recombinant glycoprotein as an antigen suitable for the development of new standard immunological tests for screening and confirmatory diagnosis of bovine brucellosis in regions or countries with brucellosis-control programs. Copyright © 2014 Elsevier B.V. All rights reserved.
Massive glutamine cyclization to pyroglutamic acid in human serum discovered using NMR spectroscopy.
Nagana Gowda, G A; Gowda, Yashas N; Raftery, Daniel
2015-04-07
Glutamine is one of the most abundant metabolites in blood and is a precursor as well as end product central to numerous important metabolic pathways. A number of surprising and unexpected roles for glutamine, including cancer cell glutamine addiction discovered recently, stress the importance of accurate analysis of glutamine concentrations for understanding its role in health and numerous diseases. Utilizing a recently developed NMR approach that offers access to an unprecedented number of quantifiable blood metabolites, we have identified a surprising glutamine cyclization to pyroglutamic acid that occurs during protein removal. Intact, ultrafiltered and protein precipitated samples from the same pool of human serum were comprehensively investigated using (1)H NMR spectroscopy at 800 MHz to detect and quantitatively evaluate the phenomenon. Interestingly, although glutamine cyclization occurs in both ultrafiltered and protein precipitated serum, the cyclization was not detected in intact serum. Strikingly, due to cyclization, the apparent serum glutamine level drops by up to 75% and, concomitantly, the pyroglutamic acid level increases proportionately. Further, virtually under identical conditions, the magnitude of cyclization is vastly different for different portions of samples from the same pool of human serum. However, the sum of glutamine and pyroglutamic acid concentrations in each sample remains the same for all portions. These unexpected findings indicate the importance of considering the sum of apparent glutamine and pyroglutamic acid levels, obtained from the contemporary analytical methods, as the actual blood glutamine level for biomarker discovery and biological interpretations.
Morrill, K M; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H
2013-07-01
Objectives of this study were to develop a rapid calf-side test to determine serum IgG concentrations using caprylic acid (CA) fractionation, followed by refractometry of the IgG-rich supernatant and compare the accuracy of this method with results obtained using refractometry using raw serum. Serum samples (n=200) were obtained from 1-d-old calves, frozen (-20°C), and shipped to the laboratory. Samples were allowed to thaw for 1h at room temperature. Fractionation with CA was conducted by adding 1mL of serum to a tube containing 45, 60, or 75µL of CA and 0.5, 1.0, or 1.5mL of 0.06 M acetic acid. The tube contents were mixed well, allowed to react for 1 min, and then centrifuged at 3,300 × g for 0, 10, or 20 min at 25°C. The %Brix and refractive index of the fractionated supernatant were determined using a digital refractometer. Nonfractionated serum was analyzed for %Brix (BRn), refractive index (nDn), and IgG concentration by radial immunodiffusion. The mean serum IgG concentration was 19.0 mg/mL [standard deviation (SD)=9.7], with a range of 3.5 to 47.0 mg/mL. The mean serum BRn was 8.6 (SD=0.91), with a range of 6.8 to 11.0. The mean serum nDn was 1.34566 (SD=0.00140), with a range of 1.34300 to 1.34930. Serum nDn was positively correlated with IgG concentration (correlation coefficient=0.86; n=185). Fractionated samples treated with 1mL 0.6 M acetic acid and 60µL of CA and not centrifuged before analysis resulted in a strong relationship between the refractive index of the fractionated supernatant and IgG (correlation coefficient=0.80; n=45). Regression was used to determine cut points indicative of 10, 12, and 14 mg of IgG/mL to determine the sensitivity and specificity of refractometry to identify failure of passive transfer (serum IgG <10 mg/mL at 24 h old). The nDn were 1.34414, 1.34448, and 1.34480 to predict 10, 12, and 14 mg of IgG/mL of serum, respectively. The BRn cut points were 7.6, 7.8, and 8.0, respectively. The nDn cut points of 1.34448 and 1.34480 resulted in similar specificities (82.9%), whereas the 1.34414 cut point had a specificity of 60.0%. The BRn cut point of 7.6 and 7.8%Brix resulted in a similar percentage of correctly classified samples (89.7 and 90.8%, respectively); however, the 7.8% Brix cut point resulted in fewer false positives. These results suggest that Brix refractometry of nonfractionated calf serum provides a strong estimate of IgG concentration and 7.8% Brix may be used as the cut point to identify failure of passive transfer in 1-d-old calves. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Carrasco, Juan Antonio Péculo; Escorza, Juana Gómez; Sánchez, María Del Mar Casal; Bouza, Mónica Rodríguez; Sanchez, José Luis Avecilla; Ruiz, Hugo José Rodríguez
2008-01-01
The authors detail the characteristics for the sterility of drained serums placed in a mobile emergency service unit and they determine how much time they can maintain optimum conditions for the use of these serums by means of a controlled, random, triple blind clinical test in which the units studied were serums prepared by an infusion system and a three-way valve. Data were gathered during a 12 month study period. The authors designed six operating groups based on their exposure time and where they were kept. These samples totaled 672 units. The authors carried out 12 microbiological cultural analyses for each unit; these analyses were tested for bacteria and fungi, both aerobic and anaerobic. The authors contrasted their hypothesis with a multivariable logistic regression model used as the variable for sterility A value of p < 0.05 was considered to be significant. Results were obtained on 669 serums, 98.82% of samples. Colonization was found in 1.7% of the 8028 cultures analyzed; in only 2 cases was there a register greater than 10 UFC/ml. This colonization corresponded to 103 serums which were then classified as non-sterile. For sterility the logistic regression model did not show any significant association with the various operating groups, which were controlled by means of two possible variable methods. The authors did not find evidence that recently drained serums were different, from the point of view of sterility, than the serums exposed during 24, 48 or 72 hours but, as well as for the groups, the incidences of these serums tripled the risk of colonization. The authors concluded they could use serums prepared previously and these serums sterility were guaranteed to the same degree as recently drained serums.
Silva, F M O; Vergara-Parente, J E; Gomes, J K N; Teixeira, M N; Lima, R P
2007-04-01
Serum chemistry analyses represents a fundamental tool for the diagnosis and understanding of diseases in marine mammals. Although several studies are being conducted within the field of clinical pathology, haematological and serum chemistry data for Antillean manatees are deficient. The purpose of this study was to determine serum chemistry values for captive Antillean manatees within the CMA/Ibama facility in Brazil. Serum samples were obtained from five captive adult Antillean manatees fed with seagrass and analysed for aspartate aminotransferase, alanine aminotransferase, bilirubin, alkaline phosphatase, urea, creatinine, glucose, triglycerides, cholesterol, total protein, albumin, globulin, phosphate, chloride, calcium and uric acid. Blood chemistry parameters were determined using a semi-automatic analyzer. Maximum, minimum, mean and standard deviations were calculated for each serum chemistry parameter. Differences on the values of males and females were verified using an unpaired Student's t-test. All the parameters analysed were similar between sexes, with exception of AP, which was higher in females (191.43 +/- 31.86 U/l). Alanine aminotransferase and uric acid values for Trichechus manatus manatus are reported for the first time in this paper. This study is the first to report serum chemistry parameter values for long-term captive male and female Antillean manatees. Therefore, the lower values of albumin, phosphate, chloride, cholesterol and triglycerides obtained here highlight the importance of clinical pathology during health monitoring of captive marine mammals.
el-Zoghbi, M; Sitohy, M Z
2001-04-01
Male albino rats were fed diets contained 6.85% mineral salts for 2 weeks (adaptation condition). Then they were fed the dietary pectin administered diet for 6 weeks to evaluate the effect of administration of pectin on the absorption of some monovalent, bivalent and heavy metals in the serum of rats. The experimental parameters included, monovalent minerals (K, Na), bivalent minerals (Zn, Cu, Ca, Fe), heavy metals (Pb, Cd), serum uric acid and serum creatinine. The obtained results indicated that the serum contents of monovalent minerals were negatively affected by pectin administration. The low degree of esterification of pectin was more effective on the absorption of bivalent minerals. Also, the rat serum levels of lead and cadmium were reduced by pectin administration. Serum total proteins were reduced by pectin administration. The level of rat serum of uric acid and creatinine fed different sources of pectin were within normal levels and were insignificantly lower than that recorded for control samples.
Canine cancer screening via ultraviolet absorbance and fluorescence spectroscopy of serum proteins
NASA Astrophysics Data System (ADS)
Dickerson, Bryan D.; Geist, Brian L.; Spillman, William B., Jr.; Robertson, John L.
2007-11-01
A cost-effective optical cancer screening and monitoring technique was demonstrated in a pilot study of canine serum samples and was patented for commercialization. Compared to conventional blood chemistry analysis methods, more accurate estimations of the concentrations of albumin, globulins, and hemoglobin in serum were obtained by fitting the near UV absorbance and photoluminescence spectra of diluted serum as a linear combination of component reference spectra. Tracking these serum proteins over the course of treatment helped to monitor patient immune response to carcinoma and therapy. For cancer screening, 70% of dogs with clinical presentation of cancer displayed suppressed serum hemoglobin levels (below 20 mg/dL) in combination with atypical serum protein compositions, that is, albumin levels outside of a safe range (from 4 to 8 g/dL) and globulin levels above or below a more normal range (from 1.7 to 3.7 g/dL). Of the dogs that met these criteria, only 20% were given a false positive label by this cancer screening test.
Skibinska, A; Lee, A; Wylie, M; Smyth, V J; Welsh, M D; Todd, D
2015-01-01
The development of an indirect enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of Group B chicken astrovirus (CAstV) infections is described. The test was based on the use of an affinity-purified capsid antigen, specific to CAstV isolate 11672, produced as a glutathione-S-transferase N-terminal fusion protein by a recombinant baculovirus. Strongly positive ELISA signals were elicited against experimentally produced antisera raised to CAstVs from Group B (subgroups i and ii) but were negative for antisera raised to a Group A CAstV. Using a panel of 240 selected serum samples, 99% agreement was observed when the results obtained by ELISA were compared to those from an indirect immunofluorescence test for CAstV 11672. The ELISA test was applied to 68 serum sets comprising 1864 samples, which were obtained from parent and grandparent flocks originating mainly in the UK. Of the 52 sets containing ELISA-positive samples, 24 sets had >75% samples positive and nine sets had <25% samples positive and were regarded as having high and low seropositivities, respectively. Of the 1864 serum samples tested 1090 (58.5%) were ELISA positive and of these, 234 sera (21.5%) produced strongly positive signals, whereas moderately positive and weakly positive signals were produced by 562 (51.5%) and 294 (27%) sera. When used for flock screening purposes, this ELISA test can be used to (i) investigate the occurrence of first-time CAstV infections of parent flocks during lay and the possible adverse effects caused by vertically transmitted CAstV infections on broiler hatchability and performance and (ii) diagnose Group B CAstV infections within specific pathogen free flocks.
Semevolos, Stacy A; Reed, Shannon K; Schultz, Loren G
2013-01-01
To characterize serum trace mineral, sex steroid hormone, and vitamin D concentrations and identify factors associated with metacarpophalangeal and metatarsophalangeal hyperextension in llamas and alpacas. Serum samples from 79 llamas and 15 alpacas and owner survey data for 573 llamas and 399 alpacas. Serum samples were stored at -20°C until analysis and were evaluated for trace mineral, vitamin D, estradiol, progesterone, and testosterone concentrations. Information regarding age of onset, number of affected animals in herd, feed and supplements given, type of housing, and management practices was obtained in an owner survey. Higher serum zinc and iron concentrations were associated with metacarpophalangeal and metatarsophalangeal hyperextension in camelids, compared with controls. In summer and fall months, vitamin D concentrations were significantly higher in affected camelids than controls. Overall prevalence was 13.3% in llamas, compared with 0.7% in alpacas. No management factors were found to be predictive of this condition. No other factors examined were associated with metacarpophalangeal and metatarsophalangeal hyperextension. Despite similar supplementation practices and environmental conditions between affected and unaffected animals, an association of high serum zinc, iron, and vitamin D concentrations in affected camelids, compared with controls, may indicate differences of intake or absorption of dietary supplements.
Banse, Heidi E; McKenzie, Erica C; Nelson, Stuart; Hinchcliff, Kenneth W
2008-06-01
To determine serum antibody titers against canine distemper virus (CDV), canine adenovirus type II (CAV-2), and canine parvovirus (CPV) in trained sled dogs prior to and after completion of a long-distance race. Prospective cohort study. 195 Alaskan sled dogs (from 18 kennels) that participated in the 2006 Iditarod Trail Race. All 1,323 dogs participating in the race had been vaccinated against the 3 viruses at 19 to 286 days prior to initial blood sample collection (obtained within the month preceding the race). Within 12 hours of race completion, blood samples were collected from 195 dogs (convenience sample) and matched with each dog's prerace sample. Serum antibody titers (90% confidence intervals [CIs]) were determined via serum neutralization assays. After racing, geometric mean titers against CDV and CPV were significantly higher (2,495 [90% CI, 321 to 16,384] and 6,323 [90% CI, 512 to 32,768], respectively) than prerace values (82 [90% CI, 11 to 362] and 166 [90% CI, 32 to 1,024], respectively). Sixty-one of 194 (31.4%) dogs had > or = 4-fold increases in anti-CPV antibody titers after racing. Prerace serum antibody titers against CDV, CPV, and CAV-2 varied significantly by sled team but were not associated with time since vaccination. Postrace increases in serum anti-CDV and anti-CPV antibody titer might reflect exposure of dogs to these agents immediately before or during racing. Dogs had no clinical signs of CDV-, CAV-2-, or CPV-associated disease; therefore, the clinical importance of these titer changes is uncertain.
Bi, Cong; Zheng, Xiwei; Hage, David S
2016-02-05
In the circulatory system, many drugs are reversibly bound to serum proteins such as human serum albumin (HSA) and alpha1-acid glycoprotein (AGP), resulting in both free and protein-bound fractions for these drugs. This report examined the use of microcolumns containing immobilized AGP for the measurement of free drug fractions by ultrafast affinity extraction and a two-dimensional affinity system. Several drugs known to bind AGP were used as models to develop and evaluate this approach. Factors considered during the creation of this method included the retention of the drugs on the microcolumns, the injection flow rate, the microcolumn size, and the times at which a second AGP column was placed on-line with the microcolumn. The final system had residence times of only 110-830ms during sample passage through the AGP microcolumns and allowed free drug fractions to be determined within 10-20min when using only 3-10μL of sample per injection. This method was used to measure the free fractions of the model drugs at typical therapeutic levels in serum, giving good agreement with the results obtained by ultrafiltration. This approach was also used to estimate the binding constants for each drug with AGP in serum, even for drugs that had significant interactions with both AGP and HSA in such samples. These results indicated that AGP microcolumns could be used with ultrafast affinity extraction to measure free drug fractions in a label-free manner and to study the binding of drugs with AGP in complex samples such as serum. Copyright © 2015 Elsevier B.V. All rights reserved.
Bonis, J; Baillou, A; Barin, F; Verdier, M; Janvier, B; Denis, F
1993-01-01
We describe enzyme immunoassays that use synthetic oligopeptides to discriminate serologically between human T-cell lymphotropic virus type I and II (HTLV-I and HTLV-II) infections. The peptides represented 20-amino acid segments between residues 111 and 130 (MA1) and residues 116 and 135 (MA2) of the p19 gag proteins of HTLV-I and HTLV-II, respectively. The assays were sensitive since 69 of 74 HTLV-positive sera were reactive to at least one of the two matrix (MA) peptides (sensitivity, 93.2%). By using the ratio of the optical density of MA1 to the optical density of MA2, which represents for every serum sample the ratio between the absorbance value obtained in the MA1 assay and the absorbance value obtained in the MA2 assay, 59 of the 69 reactive serum samples were clearly and easily typed as positive for either antibody to HTLV-I or antibody to HTLV-II. Eight of the 10 remaining reactive serum samples were analyzed further by an inhibition procedure, and their type specificities were then clearly identifiable. Therefore, the results indicate that all MA-reactive sera were serologically distinguished by our peptide assays. Images PMID:8314990
2013-01-01
Background Anniston, Alabama, is the site of a former Monsanto plant where polychlorinated biphenyls (PCBs) were manufactured from 1929 until 1971. Residents of Anniston are known to have elevated levels of PCBs. The objective of the study was to test the hypothesis that levels of the various lipid components (total cholesterol, LDL cholesterol, HDL cholesterol, triglycerides) are differentially associated with concentrations of total PCBs and total pesticides, and further that different congeners, congener groups and different pesticides do not have identical associations in serum samples obtained from Anniston residents in a cross-sectional study. Methods Fasting serum samples were obtained from 575 residents of Anniston who were not on any lipid-lowering medication and were analyzed for 35 PCB congeners, nine chlorinated pesticides, total cholesterol, LDL and HDL cholesterol and triglyceride concentrations. Associations between toxicant concentrations and lipid levels were determined using multiple linear regression analysis. Results We observed that elevated serum concentrations of lipids were associated with elevated serum concentrations of ΣPCBs and summed pesticides in analyses adjusted for age, race, gender, BMI, alcohol consumption, smoking and exercising status. The strongest associations were seen for PCB congeners with three, four, or at least eight substituted chlorines. Mono-ortho substituted congeners 74 and 156, di-ortho congeners 172 and 194, and tri- and tetra-ortho congeners 199, 196–203, 206 and 209 each were significantly associated with total lipids, total cholesterol and triglycerides. Serum concentrations of HCB and chlordane also had strong associations with lipid components. Conclusions Increased concentrations of PCBs and organochlorine pesticides are associated with elevations in total serum lipids, total cholesterol and triglycerides, but the patterns are different for different groups of PCBs and different pesticides. These observations show selective effects of different organochlorines on serum concentrations of different groups of lipids. This elevation in concentrations of serum lipids may be the basis for the increased incidence of cardiovascular disease found in persons with elevated exposures to PCBs and chlorinated pesticides. PMID:24325314
Park, Se Jin; Han, Sung Sik; Anvarov, Khikmat; Khajibaev, Abdukhakim; Choi, Min-Ho; Hong, Sung-Tae
2015-12-01
Cystic echinococcosis (CE) is one of the most widespread zoonotic helminthiases, which can last an asymptomatic infection for several years. The purpose of this study was to demonstrate serum antibody prevalence of CE among asymptomatic people in Uzbekistan using ELISA. A total of 2,547 serum samples were collected, 66 from confirmed CE patients and 2,481 of patients with other diseases than CE at a hospital in Tashkent, Uzbekistan. The serum samples were screened for CE specific IgG antibodies by ELISA using cystic fluid antigen obtained from sheep. The serum antibody positive rate was 89.4% (59/66) in CE and 3.6% (89/2,481) in other disease patients. The present ELISA recognized 89.4% sensitivity and 96.4% specificity. The ELISA absorbance of positive samples was distributed 0.271-0.971 for CE and 0.273-0.887 for other disease patients. The other disease patients with high absorbance over 0.3 were 50 (2.0%) who were presumed to be active CE patients. The patients in their 40s showed the highest positive rate of 5.2% (P=0.181), and women were 4.4% while men were 3.1% positive (P=0.136). The data confirmed that there are many asymptomatic patients of CE in Tashkent. It is indicated that CE is an endemic disease of public health importance in Uzbekistan.
Oshima, Minako; Deitiker, Philip; Hastings-Ison, Tandy; Aoki, K Roger; Graham, H Kerr; Atassi, M Zouhair
2017-05-15
We have conducted a 26-month-long comparative study involving young patients (2-6years old) with a clinical diagnosis of spastic equinus secondary to cerebral palsy who have been treated with BoNT/A (BOTOX®, Allergan) tri-annually or annually. Serum samples were obtained to determine the presence or absence of blocking antibodies (Abs) by a mouse protection assay (MPA) and levels of anti-BoNT/A Abs by radioimmune assay (RIA). HLA DQ alleles were typed using blood samples to determine the possible association of certain HLA type(s) with the disease or with the Ab status. Blocking Abs were detected in only two out of 18 serum samples of the tri-annual group, but none were found in 20 samples of the annual group. The MPA-positive serum samples gave in RIA significantly higher anti-BoNT/A Ab-binding levels than the MPA-negative samples. On the other hand, when two MPA-positive sample data were excluded, serum samples from tri-annual and annual groups showed similar anti-BoNT/A Ab levels. Linkage of the disorder with a particular HLA DQA1 and DQB1 allele types was not observed due to the small sample size. However, by combining results with other studies on BoNT/A-treated Caucasian patients with cervical dystonia (CD), we found that, among Caucasian patients treated with BoNT/A, DQA1*01:02 and DQB1*06:04 were higher in Ab-positive than in Ab-negative patients. The genetic linkage was on the threshold of corrected significance. Copyright © 2017. Published by Elsevier B.V.
Serum protein electrophoretic pattern in one-humped camels (Camelus dromedarius) in Tripoli, Libya.
Abdoslam, Omran; Bayt-Almal, Mahmoud; Almghrbe, Abdullah; Algriany, Omran
2018-01-01
The aim of this study was to characterize serum protein capillary electrophoretic pattern in apparently healthy adult male (age: 3-7 years) dromedary camels and also evaluate total protein and albumin levels using automated analyzer. Blood samples were taken from 20 camels. 5ml of blood was collected from the jugular vein and serum was separated from samples by centrifugation. Capillary electrophoresis of serum proteins identified six protein fractions in adult camels, including albumin, alpha1, alpha2, beta1, beta2 and gamma globulins, serum levels of these parameters were 3.9±0.04 g/dl, 0.16±0.01 g/dl, 0.39±0.03 g/dl, 0.515±0.03 g/dl, 0.205±0.01 g/dl and 0.61±0.04 g/dl, and 65.42±0.62 g/l, respectively. The total protein concentration was 65.42±0.62 g/L, while, the albumin/globulin (A/G) ratio was 2.4±0.14. The present study indicates six peaks with minicapillary electrophoresis and the results obtained were compared and interpreted in the light of finding reported by other investigators in camels.
Serologic and hematologic values of wild coyotes in Wisconsin
Smith, G.J.; Rongstad, O.J.
1980-01-01
Blood samples were obtained from 30 coyotes (Canis latrans) captured in northern Wisconsin in conjunction with radio-telemetry studies. Samples were assayed for seven hematologic values, seven serum chemistries, serum albumin, globulin and total protein. Results are given with respect to sex and age and are compared with available data for captive wild and pen-raised coyotes. Leukocyte counts were greater for males than females and packed cell volumes were greater for adults than young, possibly due to differential response to capture and handling stress. Hemoglobin concentrations and calcium levels suggest differences in nutrition between pen-raised and wild coyotes. Sex and age differences in serum calcium for wild coyotes probably reflect nutritional differences between groups examined. Juvenile coyote serum alkaline phosphatase levels declined curvilinearly with age for coyotes less than one year old, suggesting a possible technique for separating juveniles and yearlings captured in autumn that are released for research purposes. Elevated glucose levels and leukocyte counts in wild coyotes may reflect greater handling stress than for pen-raised and captive coyotes. No significant sex or age effects were found for levels of serum urea nitrogen, total protein, cholesterol, and total bilirubin.
Fukasawa, Lucila Okuyama; Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares
2017-01-01
The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo's national surveillance for routine diagnosis were selected for this study. The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory's standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer's instructions. The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory's standard methodology, results showed high concordance, with Kappa index ranges of 0.9877-1.00 for CSF, and 0.8004-1.00 for serum samples. The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost.
Eison, T. Matthew; Hastings, M. Colleen; Moldoveanu, Zina; Sanders, John T.; Gaber, Lillian; Walker, Patrick D.; Lau, Keith K; Julian, Bruce A.; Novak, Jan; Wyatt, Robert J.
2012-01-01
Objective: To determine whether the absence of mesangial IgG deposits is associated with the absence of elevated blood levels of galactose-deficient IgA1 (Gd-IgA1) in pediatric patients with IgA nephropathy (IgAN). Design and methods: Serum Gd-IgA1 levels were determined by ELISA using an N-acetylgalactosamine-specific lectin from Helix aspersa. Levels of Gd-IgA1 above the 90th percentile for healthy pediatric controls were considered to be elevated. Renal biopsy samples were examined by immunofluorescence for presence and intensity of staining for IgA, IgG, IgM, C3 and C1q and by light microscopy for histological changes. Findings were graded by a single pathologist (L. Gaber) at UTHSC until 2007 and by NephropathTM (Little Rock, AR, USA) thereafter. Staining for the mesangial deposits was considered negative when intensity was trace or less, and positive at greater intensity. Fisher’s exact-test was used to determine significance of 2 × 2 tables. Results: Serum samples were obtained from 30 patients with IgAN diagnosed before age 18 years. Male : female ratio was 2.3 : 1. Twenty were Caucasian and 10 were African-American. Blood was obtained within 3 months of biopsy (incident cases) for 12, while 18 provided blood > 3 months after biopsy (prevalent cases). Serum Gd-IgA1 level was elevated in 23 (77%) of cases and 20 (67%) had a biopsy positive for IgG. Of those 20 patients, 18 (90%) had an elevated serum Gd-IgA1 level, whereas 5 (50%) of patients with biopsies without IgG had a normal serum Gd-IgA1 level (p = 0.026). Summary: In this small study we found a weak association between the absence of IgG in the biopsy and normal serum Gd-IgA1 level. PMID:23006340
NASA Astrophysics Data System (ADS)
Wang, Chun Wei; Manne, Upender; Reddy, Vishnu B.; Oelschlager, Denise K.; Katkoori, Venkat R.; Grizzle, William E.; Kapoor, Rakesh
2010-11-01
A combination tapered fiber-optic biosensor (CTFOB) dip probe for rapid and cost-effective quantification of proteins in serum samples has been developed. This device relies on diode laser excitation and a charged-coupled device spectrometer and functions on a technique of sandwich immunoassay. As a proof of principle, this technique was applied in a quantitative estimation of interleukin IL-6. The probes detected IL-6 at picomolar levels in serum samples obtained from a patient with lupus, an autoimmune disease, and a patient with lymphoma. The estimated concentration of IL-6 in the lupus sample was 5.9 +/- 0.6 pM, and in the lymphoma sample, it was below the detection limit. These concentrations were verified by a procedure involving bead-based xMAP technology. A similar trend in the concentrations was observed. The specificity of the CTFOB dip probes was assessed by analysis with receiver operating characteristics. This analysis suggests that the dip probes can detect 5-pM or higher concentration of IL-6 in these samples with specificities of 100%. The results provide information for guiding further studies in the utilization of these probes to quantify other analytes in body fluids with high specificity and sensitivity.
McCracken, M M; Morrill, K M; Fordyce, A L; Tyler, H D
2017-10-01
Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG <10 mg/mL at 24 h of life). Brix cut-points analyzed were 7.1, 7.3, and 7.6%; TP cut-points were 4.6, 5.0, and 5.5 g/dL; and nD cut-points were 1.34332, 1.34271, and 1.3448, respectively, for 10, 12, and 14 mg of IgG/mL. The 7.3% Brix and 4.6 g/dL TP cut-points resulted in the greatest percentage of samples being correctly classified. These data suggest that digital refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Costa, Márcio Reis da; Costa, Izaias Pereira da; Devalle, Sylvie; Castro, Ana Rita Coimbra Motta de; Freitas, Solange Zacalusni
2012-01-01
Recent studies on the torque teno virus (TTV), genus Anellovirus, have allowed formulating the hypothesis that TTV may trigger autoimmune rheumatic diseases or have some pathogenic role in them. To determine the frequency of TTV infection in patients with systemic lupus erythematosus (SLE), the genetic diversity of TTV, the correlation between TTV infection and SLE clinical manifestations, and SLE clinical course and serological profile. Serum samples were obtained from 46 SLE patients treated at the University-Affiliated Hospital of Campo Grande (NHU/FAMED/UFMS), Brazil. For controls, serum samples were obtained from 46 healthy volunteer blood donors. Viral DNA was extracted from samples using the QIAamp DNA Blood Mini Kit (QIAGEN, Hilden, Germany) and amplified using nested PCR. Positivity for TTV was found in 17 (37%) of SLE patients and in only seven (15.2%) of the controls (z test, P = 0.03). There was no correlation between TTV infection, SLE clinical manifestations, SLE clinical course, and the serological profile of the patients evaluated. Further studies on the presence of TTV in SLE patients are required.
Dyspepsia treatment with Al compounds widely used in clinical practice — an animal model approach
NASA Astrophysics Data System (ADS)
Pinheiro, T.; Canena, J.; Reis, J.; Santos, A. M.; Pinto, A. S.; Quina, M. G.; Reis, M. A.; Alves, L. C.
1996-04-01
The potential toxic effects of Al to organs and tissues used in drugs commonly applied in dyspepsia as therapeutic, have been studied. Brain, liver, kidney and serum samples obtained from Wistar rats treated with two commercial Al complexes were studied and compared with equivalent samples collected from healthy animals receiving a placebo. The major alterations found, connected with the persistent intake of medicaments based on Al compounds, are relative to the accumulation of Al in liver and kidney. Also, the Al levels increase in brain and serum of rats supplemented with one of the Al complexes used. In the liver and kidney samples analyzed alterations in the Cu and Zn content levels were observed. Furthermore, a tendency to the decrease of Fe content in kidney and an increase of the Mn levels in brain is observed. The elemental alterations found are probably related to the intake of the drugs tested and are dependent on the type of the Al complex administered. The results obtained suggest that the long term use of these medicaments in the clinical practice should be thought over.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.
2012-08-03
Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the developmentmore » of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.« less
Elevations in the Fasting Serum Proinsulin-to-C-Peptide Ratio Precede the Onset of Type 1 Diabetes.
Sims, Emily K; Chaudhry, Zunaira; Watkins, Renecia; Syed, Farooq; Blum, Janice; Ouyang, Fangqian; Perkins, Susan M; Mirmira, Raghavendra G; Sosenko, Jay; DiMeglio, Linda A; Evans-Molina, Carmella
2016-09-01
We tested whether an elevation in the serum proinsulin-to-C-peptide ratio (PI:C), a biomarker of β-cell endoplasmic reticulum (ER) dysfunction, was associated with progression to type 1 diabetes. Fasting total PI and C levels were measured in banked serum samples obtained from TrialNet Pathway to Prevention (PTP) participants, a cohort of autoantibody-positive relatives without diabetes of individuals with type 1 diabetes. Samples were obtained ∼12 months before diabetes onset from PTP progressors in whom diabetes developed (n = 60), and were compared with age-, sex-, and BMI-matched nonprogressors who remained normoglycemic (n = 58). PI:C ratios were calculated as molar ratios and were multiplied by 100% to obtain PI levels as a percentage of C levels. Although absolute PI levels did not differ between groups, PI:C ratios were significantly increased in antibody-positive subjects in whom there was progression to diabetes compared with nonprogressors (median 1.81% vs. 1.17%, P = 0.03). The difference between groups was most pronounced in subjects who were ≤10 years old, where the median progressor PI:C ratio was nearly triple that of nonprogressors; 90.0% of subjects in this age group within the upper PI:C quartile progressed to the development of diabetes. Logistic regression analysis, adjusted for age and BMI, demonstrated increased odds of progression for higher natural log PI:C ratio values (odds ratio 1.44, 95% CI 1.02, 2.05). These data suggest that β-cell ER dysfunction precedes type 1 diabetes onset, especially in younger children. Elevations in the serum PI:C ratio may have utility in predicting the onset of type 1 diabetes in the presymptomatic phase. © 2016 by the American Diabetes Association.
Elevations in the Fasting Serum Proinsulin–to–C-Peptide Ratio Precede the Onset of Type 1 Diabetes
Sims, Emily K.; Chaudhry, Zunaira; Watkins, Renecia; Syed, Farooq; Blum, Janice; Ouyang, Fangqian; Perkins, Susan M.; Mirmira, Raghavendra G.; Sosenko, Jay; DiMeglio, Linda A.
2016-01-01
OBJECTIVE We tested whether an elevation in the serum proinsulin–to–C-peptide ratio (PI:C), a biomarker of β-cell endoplasmic reticulum (ER) dysfunction, was associated with progression to type 1 diabetes. RESEARCH DESIGN AND METHODS Fasting total PI and C levels were measured in banked serum samples obtained from TrialNet Pathway to Prevention (PTP) participants, a cohort of autoantibody-positive relatives without diabetes of individuals with type 1 diabetes. Samples were obtained ∼12 months before diabetes onset from PTP progressors in whom diabetes developed (n = 60), and were compared with age-, sex-, and BMI-matched nonprogressors who remained normoglycemic (n = 58). PI:C ratios were calculated as molar ratios and were multiplied by 100% to obtain PI levels as a percentage of C levels. RESULTS Although absolute PI levels did not differ between groups, PI:C ratios were significantly increased in antibody-positive subjects in whom there was progression to diabetes compared with nonprogressors (median 1.81% vs. 1.17%, P = 0.03). The difference between groups was most pronounced in subjects who were ≤10 years old, where the median progressor PI:C ratio was nearly triple that of nonprogressors; 90.0% of subjects in this age group within the upper PI:C quartile progressed to the development of diabetes. Logistic regression analysis, adjusted for age and BMI, demonstrated increased odds of progression for higher natural log PI:C ratio values (odds ratio 1.44, 95% CI 1.02, 2.05). CONCLUSIONS These data suggest that β-cell ER dysfunction precedes type 1 diabetes onset, especially in younger children. Elevations in the serum PI:C ratio may have utility in predicting the onset of type 1 diabetes in the presymptomatic phase. PMID:27385327
Cundy, Thomas P; Cundy, William J; Antoniou, Georgia; Sutherland, Leanne M; Freeman, Brian J C; Cundy, Peter J
2014-11-01
Measurement of serum metal ion levels is used to determine systemic exposure to implant-derived metal debris that may be generated by processes of wear and corrosion. The aim of this study is to investigate predictors of serum metal ion levels in children undergoing instrumented spinal arthrodesis using a titanium alloy, focusing on implant characteristics and instrumentation construct design variables. This prospective longitudinal cohort study involved 33 children. Serum samples were obtained preoperatively:and at five defined interval periods over the first:two post-operative years. Samples were analysed using high resolution:inductively coupled plasma mass spectrometry to measure titanium, niobium and aluminium concentrations. Instrumentation characteristics were catalogued and construct surface area (SA) measurements calculated using an implant-specific software algorithm tool. Significantly elevated levels of serum titanium and niobium were observed (p< 0.0001), with >95 % of post-operative levels abnormally elevated. Significant predictors of serum titanium and niobium levels included time since surgery, surgical procedure (posterior or anterior fusion), number of levels fused, number of pedicle screws inserted, total rod length, total metal SA, total exposed metal SA and total metal-on-metal SA. All significant instrumentation variables were highly correlated. There is a strong relationship between implant SA and both serum titanium and niobium levels. The direct clinical implications of these findings for patients are uncertain, but remain of concern. Surgeons should be aware of the strong correlation between implant surface area of the chosen construct and the subsequent serum metal ion levels.
Identification of New Biomarkers of Low-Dose GH Replacement Therapy in GH-Deficient Patients
Cruz-Topete, Diana; Jorgensen, Jens Otto L.; Christensen, Britt; Sackmann-Sala, Lucila; Krusenstjerna-Hafstrøm, Thomas; Jara, Adam; Okada, Shigeru
2011-01-01
Context: GH secretion peaks at puberty and continues to be secreted in adulthood, albeit at a declining rate. Profound GH deficiency (GHD) in adults with pituitary disease is associated with symptoms that improve with GH substitution, but it is important to tailor the GH dose to avoid overtreatment. Measurement of serum IGF-I levels is an important clinical tool in this regard, but it is well recognized that some patients receiving GH treatment do not show an increase in IGF-I. Objective: The objective of the study was to identify novel serum biomarkers of GH treatment in adults with GHD. Design and Patients: Eight patients with profound GHD as a consequence of a pituitary adenoma or its treatment were evaluated before and 3 months after GH replacement therapy (0.2–0.4 mg/d). Main Outcome Measures: Serum proteomic changes were studied using two-dimensional gel electrophoresis and mass spectrometry. Protein profiles were analyzed and compared in serum samples obtained before and after GH treatment. Results: The levels of six serum protein spots were significantly altered after GH substitution. These proteins were identified as five isoforms of haptoglobin (decreased in posttreatment samples) and one isoform of apolipoprotein A-I (increased in posttreatment samples). Importantly, changes in the levels of the identified proteins were associated with decreases in fat mass and increases in lean mass in all patients. These results were independent of serum IGF-I levels. Conclusions: Evaluation of the identified proteins provides a novel alternative to traditional markers of GH status, such as serum IGF-I levels, to assess GH therapy in GH deficient adults. PMID:21543428
Supercritical fluid extraction of selected pharmaceuticals from water and serum.
Simmons, B R; Stewart, J T
1997-01-24
Selected drugs from benzodiazepine, anabolic agent and non-steroidal anti-inflammatory drug (NSAID) therapeutic classes were extracted from water and serum using a supercritical CO2 mobile phase. The samples were extracted at a pump pressure of 329 MPa, an extraction chamber temperature of 45 degrees C, and a restrictor temperature of 60 degrees C. The static extraction time for all samples was 2.5 min and the dynamic extraction time ranged from 5 to 20 min. The analytes were collected in appropriate solvent traps and assayed by modified literature HPLC procedures. Analyte recoveries were calculated based on peak height measurements of extracted vs. unextracted analyte. The recovery of the benzodiazepines ranged from 80 to 98% in water and from 75 to 94% in serum. Anabolic drug recoveries from water and serum ranged from 67 to 100% and 70 to 100%, respectively. The NSAIDs were recovered from water in the 76 to 97% range and in the 76 to 100% range from serum. Accuracy, precision and endogenous peak interference, if any, were determined for blank and spiked serum extractions and compared with classical sample preparation techniques of liquid-liquid and solid-phase extraction reported in the literature. For the benzodiazepines, accuracy and precision for supercritical fluid extraction (SFE) ranged from 1.95 to 3.31 and 0.57 to 1.25%, respectively (n = 3). The SFE accuracy and precision data for the anabolic agents ranged from 4.03 to 7.84 and 0.66 to 2.78%, respectively (n = 3). The accuracy and precision data reported for the SFE of the NSAIDs ranged from 2.79 to 3.79 and 0.33 to 1.27%, respectively (n = 3). The precision of the SFE method from serum was shown to be comparable to the precision obtained with other classical preparation techniques.
Acute phase proteins in the diagnosis of bovine subclinical mastitis.
Safi, Shahabeddin; Khoshvaghti, Ameneh; Jafarzadeh, Seyed Reza; Bolourchi, Mahmoud; Nowrouzian, Iradj
2009-12-01
The California mastitis test (CMT) and somatic cell count (SCC) are commonly used for diagnosis of subclinical mastitis in cattle. Acute phase proteins (APPs), as alternative biomarkers of mastitis, may increase in concentration in the absence of macroscopic changes in the milk, or may precede the onset of clinical signs. The aim of this study was to compare the accuracy of APPs measured in milk and in serum with bacterial culture for the diagnosis of bovine subclinical mastitis. One hundred and seventy-five Holstein cows were randomly selected from 7 dairy farms. Quarter milk and serum samples were taken from all cows. Milk samples were analyzed using a CMT and SCC, and for haptoglobin (MHp) and amyloid A (MAA) concentrations, and were also submitted for bacterial culture. Serum samples obtained concurrently were analyzed for haptoglobin (SHp) and amyloid A (SAA). Two-sample Wilcoxon (Mann-Whitney) test was used to compare SCC, MAA, MHp, SAA, and SHp concentrations between culture-positive and culture-negative animals. Receiver-operating characteristic analysis was used to assess the performance of each test using bacterial culture as the reference method. MAA concentration was the most accurate of the 5 tests, with a sensitivity of 90.6% and specificity of 98.3% at concentrations >16.4 mg/L. MAA and MHp had significantly larger areas under the curve than the respective serum proteins, SAA and SHp. The results suggest that measuring haptoglobin and amyloid A in milk is more accurate than serum analysis for the diagnosis of subclinical mastitis in Holstein cows.
NASA Astrophysics Data System (ADS)
Li, Shaoxin; Zhang, Yanjiao; Xu, Junfa; Li, Linfang; Zeng, Qiuyao; Lin, Lin; Guo, Zhouyi; Liu, Zhiming; Xiong, Honglian; Liu, Songhao
2014-09-01
This study aims to present a noninvasive prostate cancer screening methods using serum surface-enhanced Raman scattering (SERS) and support vector machine (SVM) techniques through peripheral blood sample. SERS measurements are performed using serum samples from 93 prostate cancer patients and 68 healthy volunteers by silver nanoparticles. Three types of kernel functions including linear, polynomial, and Gaussian radial basis function (RBF) are employed to build SVM diagnostic models for classifying measured SERS spectra. For comparably evaluating the performance of SVM classification models, the standard multivariate statistic analysis method of principal component analysis (PCA) is also applied to classify the same datasets. The study results show that for the RBF kernel SVM diagnostic model, the diagnostic accuracy of 98.1% is acquired, which is superior to the results of 91.3% obtained from PCA methods. The receiver operating characteristic curve of diagnostic models further confirm above research results. This study demonstrates that label-free serum SERS analysis technique combined with SVM diagnostic algorithm has great potential for noninvasive prostate cancer screening.
Halliwell, R E; Brim, T A; Hines, M T; Wolf, D; White, F H
1985-10-01
An enzyme linked immunosorbent assay was developed for the detection of immunoglobulin class specific antibodies to Leptospira interrogans serovar pomona in the serum and aqueous humor of horses. Serum antibody was also assayed by microscopic agglutination tests. Although higher levels of antibody were found in sera from horses with signs of uveitis, the association was not statistically significant. Antibodies to pomona were detected in the aqueous of 12 eyes from the 101 horses sampled at a slaughterhouse, and in most instances, a comparison of the aqueous/serum antibody level with that of the total aqueous/serum IgG level indicated intraocular antibody synthesis. Antibodies were also found in 4 aqueous (or vitreous) samples out of 9 obtained from horses with clinically documented uveitis and the above comparison again indicated intraocular antibody synthesis. The data point to an important role for pomona as an etiology of equine recurrent uveitis but also emphasize that the initiating cause for this disease is often obscure in that association with leptospirosis cannot be shown in many instances.
Biagini, R E; Sammons, D L; Smith, J P; Page, E H; Snawder, J E; Striley, C A F; MacKenzie, B A
2004-08-01
To evaluate potential exposure to Bacillis anthracis (Ba) spores in sampling/decontamination workers in the aftermath of an anthrax terror attack. Fifty six serum samples were obtained from workers involved in environmental sampling for Ba spores at the American Media, Inc. (AMI) building in Boca Raton, FL after the anthrax attack there in October 2001. Nineteen sera were drawn from individuals both pre-entry and several weeks after entrance into the building. Nine sera each were drawn from unique individuals at the pre-entry and follow up blood draws. Thirteen donor control sera were also evaluated. Individuals were surveyed for Ba exposure by measurement of serum Ba anti-protective antigen (PA) specific IgG antibodies using a newly developed fluorescent covalent microsphere immunoassay (FCMIA). Four sera gave positive anti-PA IgG results (defined as anti-PA IgG concentrations > or = the mean microg/ml anti-PA IgG from donor control sera (n = 13 plus 2 SD which were also inhibited > or = 85% when the serum was pre-adsorbed with PA). The positive sera were the pre-entry and follow up samples of two workers who had received their last dose of anthrax vaccine in 2000. It appears that the sampling/decontamination workers of the present study either had insufficient exposure to Ba spores to cause the production of anti-PA IgG antibodies or they were exposed to anthrax spores without producing antibody. The FCMIA appears to be a fast, sensitive, accurate, and precise method for the measurement of anti-PA IgG antibodies.
Serum TIMP1 and TIMP2 concentration in patients with different grades of meningioma.
Mashayekhi, Farhad; Saberi, Alia; Mashayekhi, Sohail
2018-07-01
Meningiomas are common primary brain tumors that constitute about 13% of all intracranial tumors. Matrix metalloproteinase-9 (MMP-9) is able to degrade the extracellular matrix and basement membrane leading to cancer cell invasion and metastasis. MMPs are specifically inhibited by a family of small extracellular proteins known as the tissue inhibitors of metalloproteinases (TIMPs). The objective of this project was to evaluate serum concentration of TIMP-1 and TIMP-2 in patients with different grades of meningioma. Ninety samples from different stages of patients with meningitis (42 cases of grade I, 28 grade II, 20 grade III) and 51 samples from normal healthy were included in this study. Total protein concentration (TPC) and the level TIMP-1 and TIMP-2 serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay (ELISA), respectively. No significant change in the TPC was seen in the serum of patients with meningioma when compared with normal controls. Results obtained demonstrated that all serum samples presented TIMP-1 and TIMP-2 expression, whereas, starting from grade I to III meningiomas, a significant decrease of TIMP-1 and TIMP-2 expression was observed as compared to controls. The results of this study show that a low expression of TIMP1 and TIMP2 is correlated with advanced stages of meningioma. It is also concluded that the detection of serum TIMP1 and TIMP2 may be useful in classifying different grades of meningioma. Copyright © 2018 Elsevier B.V. All rights reserved.
Kjelgaard-Hansen, Mads; Christensen, Michelle B; Lee, Marcel H; Jensen, Asger L; Jacobsen, Stine
2007-06-15
Serum amyloid A (SAA) is a major acute phase protein in dogs. However, knowledge of qualitative properties of canine SAA and extent of its synthesis in extrahepatic tissues is limited. The aim of the study was to investigate expression of different SAA isoforms in serum and synovial fluid in samples obtained from dogs (n=16) suffering from different inflammatory or non-inflammatory conditions, which were either related or unrelated to joints. Expression of SAA isoforms was visualized by denaturing isoelectric focusing and Western blotting. Serum amyloid A was present in serum from all dogs with systemic inflammatory activity, and up to four major isoforms with apparent isoelectric points between 6.1 and 7.9 were identified. In synovial fluid from inflamed joints one or more highly alkaline SAA isoforms (with apparent isoelectric points above 9.3) were identified, with data suggesting local production of these isoforms in the canine inflamed joint.
Deguchi, Matsuo; Kagita, Masanori; Yoshioka, Nori; Tsukamoto, Hiroko; Takao, Miyuki; Tahara, Kazuko; Maeda, Ikuhiro; Hidaka, Yoh; Yamauchi, Satoshi; Kaneko, Atsushi; Miyakoshi, Hideo; Isomura, Mitsuo
2017-10-06
Ongoing efforts in the development of HBsAg detection kits are focused on improving sensitivity and specificity. The purpose of this study was to evaluate an improved, highly sensitive quantitative assay, "Lumipulse HBsAg-HQ", a chemiluminescent enzyme immunoassay designed for a fully automated instrument, the "Lumipulse G1200". Serum samples for reproducibility, dilution, correlation, sensitivity, and specificity studies were obtained from patients at the Osaka University Hospital. Seroconversion and sensitivity panels were purchased from a commercial vender. Subtype, sensitivity panels, and HBsAg recombinant proteins with one or two amino acid substitutions were prepared in-house. The coefficients of variation for the low, medium, and high concentration samples ranged from 1.93 to 2.55%. The HBsAg-HQ reagent for dilution testing showed good linearity in the 0.005-150 HBsAg IU/mL range and no prozone phenomenon. All 102 HBV carrier samples were positive by HBsAg-HQ, while other commercial reagents showed one or more to be negative. In the seroconversion panel, the 14-day blood sample was positive. The sensitivity against HBsAg-HQ "ad" and "ay" subtypes was 0.025 ng/mL. Comparisons among the HBsAg-HQ, HISCL, and Architect HBsAg reagents were performed using the Bland-Altman plot. Specificity for 1000 seronegative individuals was 99.7%. HBsAg-HQ detected 29 positive serum among 12 231 routinely obtained serum samples, which showed concentrations of 0.005-0.05 HBsAg IU/mL. According to these results, the Lumipulse HBsAg-HQ assay, with a highly sensitive limit of detection of 0.005 IU/mL, may facilitate the development of a better management strategy for a considerable proportion of infected patients. © 2017 Wiley Periodicals, Inc.
Differential expression profiling of serum proteins and metabolites for biomarker discovery
NASA Astrophysics Data System (ADS)
Roy, Sushmita Mimi; Anderle, Markus; Lin, Hua; Becker, Christopher H.
2004-11-01
A liquid chromatography-mass spectrometry (LC-MS) proteomics and metabolomics platform is presented for quantitative differential expression analysis. Proteome profiles obtained from 1.5 [mu]L of human serum show ~5000 de-isotoped and quantifiable molecular ions. Approximately 1500 metabolites are observed from 100 [mu]L of serum. Quantification is based on reproducible sample preparation and linear signal intensity as a function of concentration. The platform is validated using human serum, but is generally applicable to all biological fluids and tissues. The median coefficient of variation (CV) for ~5000 proteomic and ~1500 metabolomic molecular ions is approximately 25%. For the case of C-reactive protein, results agree with quantification by immunoassay. The independent contributions of two sources of variance, namely sample preparation and LC-MS analysis, are respectively quantified as 20.4 and 15.1% for the proteome, and 19.5 and 13.5% for the metabolome, for median CV values. Furthermore, biological diversity for ~20 healthy individuals is estimated by measuring the variance of ~6500 proteomic and metabolomic molecular ions in sera for each sample; the median CV is 22.3% for the proteome and 16.7% for the metabolome. Finally, quantitative differential expression profiling is applied to a clinical study comparing healthy individuals and rheumatoid arthritis (RA) patients.
NASA Astrophysics Data System (ADS)
Jafari, Marzieh; Tashkhourian, Javad; Absalan, Ghodratollah
2017-10-01
A simple, fast and green method for chiral recognition of S- and R-naproxen has been introduced. The method was based on quenching of the fluorescence intensity of bovine serum albumin-stabilized gold nanoclusters in the presence of naproxen enantiomers. The quenching intensity in the presence of S-naproxen was higher than R-naproxen when phosphate buffer solution at pH 7.0 was used. The chiral recognition occurred due to steric effect between bovine serum albumin conformation and naproxen enantiomers. Two linear determination range were established as 7.4 × 10-7-9.1 × 10-6 and 9.1 × 10-6-3.1 × 10-5 mol L-1 for both enantiomers and detection limits of 7.4 × 10-8 mol L- 1 and 9.5 × 10-8 mol L-1 were obtained for S- and R-naproxen, respectively. The developed method showed good repeatability and reproducibility for the analysis of a synthetic sample. To make the procedure applicable to biological samples, the removal of heavy metals from the sample is suggested before any analytical attempt.
Seo, Dongmin; Paek, Sung-Ho; Oh, Sangwoo; Seo, Sungkyu; Paek, Se-Hwan
2016-01-01
The incidence of diabetes is continually increasing, and by 2030, it is expected to have increased by 69% and 20% in underdeveloped and developed countries, respectively. Therefore, glucose sensors are likely to remain in high demand in medical device markets. For the current study, we developed a needle-type bio-layer interference (BLI) sensor that can continuously monitor glucose levels. Using dialysis procedures, we were able to obtain hypoglycemic samples from commercial human serum. These dialysis-derived samples, alongside samples of normal human serum were used to evaluate the utility of the sensor for the detection of the clinical interest range of glucose concentrations (70–200 mg/dL), revealing high system performance for a wide glycemic state range (45–500 mg/dL). Reversibility and reproducibility were also tested over a range of time spans. Combined with existing BLI system technology, this sensor holds great promise for use as a wearable online continuous glucose monitoring system for patients in a hospital setting. PMID:27669267
Ince, Bahar; Coban, Halil; Turker, Gokhan; Ertekin, Emine; Ince, Orhan
2013-05-01
The aim of this study was to investigate the effect of a common veterinary antibiotic in biogas plants. 20 mg/kg of oxytetracycline was intramuscularly injected into a cow and its concentration in manure, which was sampled daily during the following 20 days, was measured. A total of 20 % of the injected oxytetracycline was detected in manure. Collected manure samples on days 1, 2, 3, 5, 10, 15, and 20 were digested in triplicate serum bottles at 37 °C for 30 days. Control serum bottles produced 255 ± 13 mL biogas, whereas 50-60 % inhibitions were obtained for the serum bottles operated with samples collected for the 5 days after medication. Multivariate statistics used for the evaluation of FISH results showed that Methanomicrobiales were the main methanogenic group responsible for most of the biogas production. Numbers of active Bacteria and Methanomicrobiales were negatively correlated with the presence of oxytetracycline, whereas Methanosarcinales and Methanobacteriales were less affected.
Raj, G Dhinakar; Thiagarajan, V; Nachimuthu, K
2007-09-01
A simple, user-friendly, and rapid method to detect the presence of antibodies to egg drop syndrome 76 (EDS) virus in chicken sera based on an immunofiltration (flow-through) test was developed. Purified EDS virus antigen was coated onto nitrocellulose membranes housed in a plastic module with layers of absorbent filter pads underneath. Following addition of serum to be tested and washing, monoclonal antibodies or polyclonal serum to chicken immunoglobulin G (IgG) was used as a bridge antibody to mediate binding between EDS virus-specific IgG and protein A gold conjugate. The appearance of a pink dot indicated the presence of antibodies to EDS virus in the sample tested. The results could be obtained within 5-10 min. The developed immunofiltration test could detect antibodies in the sera of experimentally vaccinated chickens from 2 wk postvaccination. With field sera samples, this test was positive in samples having hemagglutination inhibition titers of 8 and above. This test has the potential to be used as a field-based kit to assess seroconversion in EDS-vaccinated flocks.
Goitrous hypothyroidism associated with treatment with trimethoprim-sulfamethoxazole in a young dog.
Seelig, Davis M; Whittemore, Jacqueline C; Lappin, Michael R; Myers, Alan M; Avery, Paul R
2008-04-15
A 16-week-old female Boxer that had been treated for 5 weeks with trimethoprim-sulfamethoxazole and chloramphenicol because of aspiration pneumonia was evaluated for bilaterally symmetric masses in the subcutaneous tissues of the ventral neck, in the region of the larynx. Fine-needle aspirates were obtained from the neck masses; cytologic examination revealed well-differentiated thyroid epithelial tissue. A blood sample was collected for serum biochemical and thyroid function analyses. Mild hyperphosphatemia, severe hypercholesterolemia, mild hyperkalemia, and a mild increase in creatine kinase activity were identified. Serum concentration of total thyroxine was less than the lower reference limit, and that of thyroid-stimulating hormone was greater than the upper reference limit. Findings were consistent with a diagnosis of clinical hypothyroidism in a skeletally immature dog. Treatment with trimethoprim-sulfamethoxazole was discontinued. The dog was reevaluated 3 weeks later, at which time the neck masses were markedly decreased in size. Serum concentrations of cholesterol and potassium were lower; serum concentrations of total thyroxine and thyroid-stimulating hormone were near or within respective reference ranges. Age-appropriate increases in serum phosphorus concentration and serum alkaline phosphatase activity were also detected. To the authors' knowledge, this is the first report of antimicrobial-induced goiter in a dog. Cytologic examination of fine-needle aspirates and interpretation of data from serum biochemical and thyroid function analyses were needed to obtain a definitive diagnosis. Practitioners should include goiter among the differential diagnoses for ventral neck swellings in young dogs receiving potentiated sulfonamide antimicrobials.
Schmidt, Debra A; Koutsos, Elizabeth A; Ellersieck, Mark R; Griffin, Mark E
2009-03-01
Serum concentrations of amino acids, fatty acids, lipoproteins, vitamins A and E, and minerals in zoo giraffes (Giraffa camelopardalis) were compared to values obtained from free-ranging giraffes in an effort to identify potential nutritional differences in the zoo population. Zoo giraffes have a specific set of maladies that may be nutritionally related, including peracute mortality, energy malnutrition, pancreatic disease, urolithiasis, hoof disease, and severe intestinal parasitism. Dietary requirements for giraffes are not known; invasive studies used with domestic animals cannot be performed on zoo animals. Though domestic animal standards are often used to evaluate nutritional health of exotic animals, they may not be the most appropriate standards to use. Serum samples from 20 zoo giraffes at 10 zoological institutions in the United States were compared to previously collected samples from 24 free-ranging giraffes in South Africa. Thirteen of the zoo animal samples were collected from animals trained for blood collection, and seven were banked samples obtained from a previous serum collection. Dietary information was also collected on each zoo giraffe; most zoo giraffe diets consisted of alfalfa-based pellets (acid detergent fiber-16), alfalfa hay, and browse in varying quantities. Differences between zoo and free-ranging giraffes, males and females, and adults and subadults were analyzed with the use of a 2 x 2 x 2 factorial and Fisher's Least Significant Difference (LSD) for mean separation. Of the 84 parameters measured, 54 (60%) were significantly different (P < or = 0.05) between zoo and free-ranging giraffes. Nine (11%) items were significantly different (P < or = 0.05) between adult and subadult animals. Only one parameter, sodium concentration, was found to be significantly different (P < or = 0.05) between genders. Further investigation in zoo giraffe diets is needed to address the differences seen in this study and the potentially related health problems.
Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I
2015-03-01
The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.
Guthmann, Jean-Paul; Klovstad, Hilde; Boccia, Delia; Hamid, Nuha; Pinoges, Loretxu; Nizou, Jacques-Yves; Tatay, Mercedes; Diaz, Francisco; Moren, Alain; Grais, Rebecca Freeman; Ciglenecki, Iza; Nicand, Elisabeth; Guerin, Philippe Jean
2006-06-15
The conflict in Darfur, Sudan, was responsible for the displacement of 1.8 million civilians. We investigated a large outbreak of hepatitis E virus (HEV) infection in Mornay camp (78,800 inhabitants) in western Darfur. To describe the outbreak, we used clinical and demographic information from cases recorded at the camp between 26 July and 31 December 2004. We conducted a case-cohort study and a retrospective cohort study to identify risk factors for clinical and asymptomatic hepatitis E, respectively. We collected stool and serum samples from animals and performed a bacteriological analysis of water samples. Human samples were tested for immunoglobulin G and immunoglobulin M antibody to HEV (for serum samples) and for amplification of the HEV genome (for serum and stool samples). In 6 months, 2621 hepatitis E cases were recorded (attack rate, 3.3%), with a case-fatality rate of 1.7% (45 deaths, 19 of which involved were pregnant women). Risk factors for clinical HEV infection included age of 15-45 years (odds ratio, 2.13; 95% confidence interval, 1.02-4.46) and drinking chlorinated surface water (odds ratio, 2.49; 95% confidence interval, 1.22-5.08). Both factors were also suggestive of increased risk for asymptomatic HEV infection, although this was not found to be statistically significant. HEV RNA was positively identified in serum samples obtained from 2 donkeys. No bacteria were identified from any sample of chlorinated water tested. Current recommendations to ensure a safe water supply may have been insufficient to inactivate HEV and control this epidemic. This research highlights the need to evaluate current water treatment methods and to identify alternative solutions adapted to complex emergencies.
Molecular detection of Rift Valley fever virus in serum samples from selected areas of Tanzania.
Chengula, Augustino Alfred; Kasanga, Christopher Jacob; Mdegela, Robinson Hammerthon; Sallu, Raphael; Yongolo, Mmeta
2014-04-01
Rift Valley fever (RVF) is an acute mosquito-borne viral zoonotic disease affecting domestic animals and humans caused by the Rift Valley fever virus (RVFV). The virus belongs to the genus Phlebovirus of the family Bunyaviridae. The main aim of this study was to detect the presence of antibodies to RVFV as well as the virus in the serum samples that were collected from livestock during the 2006/2007 RVF outbreaks in different locations in Tanzania. Analysis of selected samples was done using a RVF-specific inhibition enzyme-linked immunosorbent assay (I-ELISA) and reverse transcription polymerase chain reaction (RT-PCR). Genomic viral RNA was extracted directly from serum samples using a QIAamp Viral RNA Mini Kit (QIAGEN), and a one-step RT-PCR protocol was used to amplify the S segment of RVFV. Positive results were obtained in 39.5% (n = 200) samples using the RVF I-ELISA, and 17.6% (n = 108) of samples were positive by RT-PCR. I-ELISA detected 41 (38.7%), 32 (39.0%), and 6 (50.0%) positive results in cattle, goats, and sheep sera, respectively, whereas the RT-PCR detected 11 (0.2%), 7 (0.2%), and 1 (0.1%) positive results in cattle, goats, and sheep sera, respectively. These findings have demonstrated the presence of RVFV in Tanzania during the 2006/2007 RVF outbreaks. To our knowledge, this is the first report to detect RVFV in serum samples from domestic animals in Tanzania using PCR technique. Therefore, a detailed molecular study to characterize the virus from different geographical locations in order to establish the profile of strains circulating in the country and develop more effective and efficient control strategies should be done.
Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D
2013-12-01
Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, < Lower Limit of Quantitation (LLQ); range, < LLQ-43.3 mcg/mL). Significant differences and associations were identified between case status and the following: 1) serum oxalic acid and serum HEAA (both OR = 14.6; 95% C I = 2.8-100.9); 2) serum diglycolic acid and urine diglycolic acid (both OR > 999; exact p < 0.0001); and 3) urinary glycolic acid (OR = 0.057; 95% C I = 0.001-0.55). Two CSF sample results were excluded and two from the same case were averaged, yielding eight samples from eight cases. Diglycolic acid was detected in seven (88%) of case CSF samples (median, 2.03 mcg/mL; range, < LLQ, 7.47). Significantly elevated HEAA (serum) and diglycolic acid (serum and urine) concentrations were identified among cases, which is consistent with animal data. Low urinary glycolic acid concentrations in cases may have been due to concurrent AKI. Although serum glycolic concentrations among cases may have initially increased, further metabolism to oxalic acid may have occurred thereby explaining the similar glycolic acid concentrations in cases and controls. The increased serum oxalic acid concentration results in cases versus controls are consistent with this hypothesis. Diglycolic acid is associated with human DEG poisoning and may be a biomarker for poisoning. These findings add to animal data suggesting a possible role for traditional antidotal therapies. The detection of HEAA and diglycolic acid in the CSF of cases suggests a possible association with signs and symptoms of DEG-associated neurotoxicity. Further work characterizing the pathophysiology of DEG-associated neurotoxicity and the role of traditional toxic alcohol therapies such as fomepizole and hemodialysis is needed.
Prevalence and causes of abnormal PSA recovery.
Lautenbach, Noémie; Müntener, Michael; Zanoni, Paolo; Saleh, Lanja; Saba, Karim; Umbehr, Martin; Velagapudi, Srividya; Hof, Danielle; Sulser, Tullio; Wild, Peter J; von Eckardstein, Arnold; Poyet, Cédric
2018-01-26
Prostate-specific antigen (PSA) test is of paramount importance as a diagnostic tool for the detection and monitoring of patients with prostate cancer. In the presence of interfering factors such as heterophilic antibodies or anti-PSA antibodies the PSA test can yield significantly falsified results. The prevalence of these factors is unknown. We determined the recovery of PSA concentrations diluting patient samples with a standard serum of known PSA concentration. Based on the frequency distribution of recoveries in a pre-study on 268 samples, samples with recoveries <80% or >120% were defined as suspect, re-tested and further characterized to identify the cause of interference. A total of 1158 consecutive serum samples were analyzed. Four samples (0.3%) showed reproducibly disturbed recoveries of 10%, 68%, 166% and 4441%. In three samples heterophilic antibodies were identified as the probable cause, in the fourth anti-PSA-autoantibodies. The very low recovery caused by the latter interference was confirmed in serum, as well as heparin- and EDTA plasma of blood samples obtained 6 months later. Analysis by eight different immunoassays showed recoveries ranging between <10% and 80%. In a follow-up study of 212 random plasma samples we found seven samples with autoantibodies against PSA which however did not show any disturbed PSA recovery. About 0.3% of PSA determinations by the electrochemiluminescence assay (ECLIA) of Roche diagnostics are disturbed by heterophilic or anti-PSA autoantibodies. Although they are rare, these interferences can cause relevant misinterpretations of a PSA test result.
Ramon-Marquez, Teresa; Medina-Castillo, Antonio L; Fernandez-Gutierrez, Alberto; Fernandez-Sanchez, Jorge F
2016-08-15
This paper describes a novel biosensor which combines the use of nanotechnology (non-woven nanofibre mat) with Solid Surface-Room Temperature Phosphorescence (SS-RTP) measurement for the determination of serotonin in human serum. The developed biosensor is simple and can be directly applied in serum; only requires a simple clean-up protocol. Therefore it is the first time that serotonin is analysed directly in serum with a non-enzymatic technique. This new approach is based on the covalent immobilization of serotonin directly from serum on a functional nanofibre material (Tiss®-Link) with a preactivated surface for direct covalent immobilization of primary and secondary amines, and the subsequent measurement of serotonin phosphorescent emission from the solid surface. The phosphorescent detection allows avoiding the interference from any fluorescence emission or scattering light from any molecule present in the serum sample which can be also immobilised on the nanofibre material. The determination of serotonin with this SS-RTP sensor overcomes some limitations, such as large interference from the matrix and high cost and complexity of many of the methods widely used for serotonin analysis. The potential applicability of the sensor in the clinical diagnosis was demonstrated by analysing serum samples from seven healthy volunteers. The method was validated with an external reference laboratory, obtaining a correlation coefficient of 0.997 which indicates excellent correlation between the two methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Lower, K S; Medleau, L M; Hnilica, K; Bigler, B
2001-12-01
Canine scabies is a challenging disease to diagnose because sarcoptic mites are hard to find on skin scrapings. The purpose of this study was to evaluate a serologic enzyme-linked immunosorbent assay (ELISA) as an aid in the diagnosis of canine scabies. In addition, serum samples were obtained post treatment to determine the duration and persistence of circulating scabies antibodies after resolution of natural infection. Nineteen dogs diagnosed with sarcoptic mange and 38 control dogs were tested. Sixteen scabies-infested dogs showed positive pretreatment ELISA results (84.2% sensitivity). Thirty-four control dogs showed negative ELISA results (89.5% specificity). In the 11 scabies dogs from which multiple post treatment serum samples were obtained, detectable antibodies were not present 1 month after treatment in four cases, but were present for 1-4.5 months post treatment in seven dogs. Our results suggest that this scabies ELISA test is useful in the diagnosis of canine scabies.
Kehinde, E O; Akanji, A O; Memon, A; Bashir, A A; Daar, A S; Al-Awadi, K A; Fatinikun, T
2006-01-01
Factors responsible for the low incidence of clinical prostate cancer (3-8/100,000 men/year) in the Arab population remain unclear, but may be related to changes in steroid hormone metabolism. We compared the levels of serum conjugated and unconjugated steroids between Arab and Caucasian populations, to determine if these can provide a rational explanation for differences in incidence of prostate cancer between the two populations. Venous blood samples were obtained from 329 unselected apparently healthy indigenous Arab men (Kuwaitis and Omanis) aged 15-80 years. Samples were also obtained from similar Arab men with newly diagnosed prostate cancer or benign prostatic hyperplasia (BPH). The samples were taken between 8:00 am and 12:00 noon. Serum levels of total testosterone, (TT), sex hormone binding globulin (SHBG), free androgen index (FAI); adrenal C19-steroids, dehydroepiandrosterone sulphate (DHEAS) and androstenedione (ADT) were determined using Immulite kits (Diagnostic Systems Laboratories Inc, Webster Texas, USA). The results obtained in Arab men were compared with those reported for similarly aged Chinese, German and White USA men. In all four ethnic groups, median TT and FAI declined with age, while SHBG increased with age. However, the mean TT and SHBG was significantly lower (p < 0.01) and the FAI significantly higher in Arab men (p < 0.01) compared to German men only in 21-30 years age group. In the other age groups the levels of TT and SHBG were higher in the Germans but the differences were not statistically significant. In all the racial groups serum levels of DHEAS and ADT reached a peak by about 20 years of life, and then declined progressively. The mean DHEAS in American Caucasians aged 20-29 years was 11.4 micromol/l compared to 6.22 micromol/l in the Arabs (p < 0.001). The mean DHEAS in USA Caucasians aged 70-79 years was 2.5 micromol/l compared to 1.8 micromol/l (p < 0.03) in the Arabs. There was no significant difference in mean serum levels of DHEAS between German and USA men. Similarly, there was no significant difference in the level of the hormones between Arab and Chinese men. Arab men with newly diagnosed prostate cancer had high serum TT, SHBG and DHEAS compared to those without the disease. The mean TT and SHBG was significantly lower in Arab men compared to Caucasian men especially in early adulthood. Caucasians have significantly higher serum levels of the precursor androgens DHEAS and ADT especially in early adulthood compared to Arab men. These observations of low circulating androgens and their adrenal precursors in Arab men may partially account for the decreased risk for prostate cancer among Arab men.
Yang, Mei; Wang, Zhuoya; Hao, Wei; Wang, Yanfang; Huang, Li; Cai, Jianpiao; Jiang, Lingxiao; Che, Xiaoyan; Zhong, Xiaozhu; Yu, Nan
2014-05-01
To establish two double-antigen sandwich ELISA systems to detect anti-Afmp1cr and Afmp2cr antibodies of Aspergillus fumigatus. Recombinant Afmp1cr and Afmp2cr proteins of A.fumigatus expressed in Pichia pastoris were obtained. Double-antigen sandwich ELISA systems for detecting specific anti-Afmp1cr and anti-Afmp2cr antibodies were developed after chessboard titrating to determine the appropriate concentrations of the recombinant proteins and HRP-labeled proteins. The sensitivity of the assay was evaluated using serum samples of rabbits immunized with Afmp1cr and Afmp2cr. The specificity of the assay was evaluated by detecting serum samples from healthy donors and patients with other pathogenic fungal and baterial infections. The performance of the two ELISA kits was furthered evaluated using serum samples from patients with suspected Aspergillus infection. The established ELISA kits were capable of detecting anti-Afmp1cr and anti-Afmp2cr antibodies in immunized rabbit serum at the maximum dilutions of 800 and 3200, respectively. No cross-reactivity was observed in detecting serum from patients with other pathogenic fungal or bactetial infections. Both of the two kits yielded positive results in sera from two established Aspergillus-infected cases and a suspected case. Two antibody-capture ELISA kits were developed for the laboratory diagnosis of A.fumigatus infection and can be potentially useful in the clinical diagnosis of Aspergillosis infections.
Antineuronal antibodies in idiopathic achalasia and gastro-oesophageal reflux disease
Moses, P L; Ellis, L M; Anees, M R; Ho, W; Rothstein, R I; Meddings, J B; Sharkey, K A; Mawe, G M
2003-01-01
Background and aims: The precise aetiology of achalasia is unknown although autoimmunity has been implicated and is supported by several studies. We screened sera from patients with achalasia or gastro-oesophageal reflux disease (GORD) to test for circulating antimyenteric neuronal antibodies. Methods: Serum was obtained from 45 individuals with achalasia, 16 with GORD, and 22 normal controls. Serum was used in immunohistochemistry to label whole mount preparations of ileum and oesophagus of the guinea pig and mouse. Also, sections of superior cervical and dorsal root ganglia, and spinal cord were examined. Results: Positive immunostaining of the myenteric plexus was detected in significantly more achalasia and GORD samples than control samples (achalasia, p<0.001; GORD, p<0.01), and immunoreactivity was significantly more intense with achalasia and GORD serum samples than controls (achalasia, p<0.01; GORD, p<0.05). There was no correlation between intensity of immunoreactivity and duration of achalasia symptoms. In most cases, achalasia and GORD sera stained all ileal submucosal and myenteric neurones, and oesophageal neurones. Immunostaining was not species specific; however, immunostaining was largely specific for enteric neurones. Western blot analysis failed to reveal specific myenteric neuronal proteins that were labelled by antibodies in achalasia or GORD serum. Conclusions: These data suggest that antineuronal antibodies are generated in response to tissue damage or some other secondary phenomenon in achalasia and GORD. We conclude that antineuronal antibodies found in the serum of patients with achalasia represent an epiphenomenon and not a causative factor. PMID:12692044
Fathipour, Vahid; Khaki, Zohreh; Nassiri, Seyyed Mehdi
2018-01-01
Recently, matrix metalloproteinases (MMP), in particular the gelatinases MMP-2 and MMP-9, generally considered as tumor markers for clinical applications. A longitudinal 2-years follow-up survey was performed on dogs with cutaneous tumor. Serum samples were obtained from 22 dogs with different cutaneous tumors and 22 health dogs at the time of surgery and one month, three months and one year after surgery. Gelatin zymography, hematological and biochemical assessment were performed for all serum samples. The serum alkaline phosphatase activity in dogs with malignant tumors was significantly higher than that in dogs with benign tumors and control cases. Latent forms of MMP-2 and MMP-9 were detected in all of the tumor cases. Gelatin zymography showed active form of MMP-9 in 12 cases (three benign and nine malignant tumors) and active form of MMP-2 in one fibrosarcoma case. Serum activity of active-MMP-9 and total MMP-9 was significantly higher in dogs with cutaneous tumors than those in controls. Tumor cases had higher serum activity of active-MMP-9 rather than controls. MMPs and alkaline phosphatase activities in serum were decreased significantly after surgery. Only one case with perianal gland adenoma showed recurrence of tumor four months after surgery in which active form of MMP-9 had identified one month before recurrence. According to the findings, it will be useful to measure ALP, MMP-2 and MMP-9 activities in the serum of dogs with cutaneous tumor for determination of tumor behavior before surgical treatment.
Bekaert, Michaël; Bakheit, Mohammed; Frischmann, Sieghard; Patel, Pranav; Simon-Loriere, Etienne; Lambrechts, Louis; Duong, Veasna; Dussart, Philippe; Harold, Graham; Fall, Cheikh; Faye, Oumar; Sall, Amadou Alpha; Weidmann, Manfred
2018-01-01
Background 4 one-step, real-time, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays were developed for the detection of dengue virus (DENV) serotypes by considering 2,056 full genome DENV sequences. DENV1 and DENV2 RT-LAMP assays were validated with 31 blood and 11 serum samples from Tanzania, Senegal, Sudan and Mauritania. DENV3 and DENV4 RT-LAMP assays were validated with 25 serum samples from Cambodia Methodology/Principal findings 4 final reaction primer mixes were obtained by using a combination of Principal Component Analysis of the full DENV genome sequences, and LAMP primer design based on sequence alignments using the LAVA software. These mixes contained 14 (DENV1), 12 (DENV2), 8 (DENV3) and 3 (DENV4) LAMP primer sets. The assays were evaluated with an External Quality Assessment panel from Quality Control for Molecular Diagnostics. The assays were serotype-specific and did not cross-detect with other flaviviruses. The limits of detection, with 95% probability, were 22 (DENV1), 542 (DENV2), 197 (DENV3) and 641 (DENV4) RNA molecules, and 100% reproducibility in the assays was obtained with up to 102 (DENV1) and 103 RNA molecules (DENV2, DENV3 and DENV4). Validation of the DENV2 assay with blood samples from Tanzania resulted in 23 samples detected by RT-LAMP, demonstrating that the assay is 100% specific and 95.8% sensitive (positive predictive value of 100% and a negative predictive value of 85.7%). All serum samples from Senegal, Sudan and Mauritania were detected and 3 untyped as DENV1. The sensitivity of RT-LAMP for DENV4 samples from Cambodia did not quite match qRT-PCR. Conclusions/Significance We have shown a novel approach to design LAMP primers that makes use of fast growing sequence databases. The DENV1 and DENV2 assays were validated with viral RNA extracted clinical samples, showing very good performance parameters. PMID:29813062
Chantada-Vázquez, María Pilar; de-Becerra-Sánchez, Carolina; Fernández-Del-Río, Alba; Sánchez-González, Juan; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2018-05-01
A molecularly imprinted polymer - Mn-doped ZnS quantum dot-based fluorescence probe for cocaine abuse screening has been prepared and applied to complex samples such as serum and oral fluid. The fluorescent sensing material was prepared by anchoring a selective MIP for COC on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). Simple and low cost methods have thus been optimized for assessing cocaine abuse in serum and oral fluid by monitoring fluorescence quenching when cocaine (COC) is present (optimized operating conditions with 1.5mL of 200mgL -1 MIP-coated QDs solution, pH 5.5, and 15min before fluorescence scanning). The matrix effect was found to be important when analyzing oral fluid and serum, and several strategies based on centrifugation for oral fluid and solid phase extraction (SPE) for serum were explored. Two analytical methods were developed for oral fluid. The first one (direct method) requires a centrifugation step (6°C, 4000rpm, 20min) to avoid the matrix effect, and allows for cocaine determination by using an aqueous calibration (1:20 dilution). The second method was developed for oral fluid sampled by Salivette devices, and also requires a further centrifugation (6°C, 4000rpm, 20min) of the recovered oral fluid. This method, however, requires the standard addition technique (1:20 dilution) because of the existence of the matrix effect. Regarding serum samples, a direct method (serum dilution) was not possible, and an SPE procedure was needed to avoid the matrix effect (use of aqueous calibration). The limits of detection and quantification when using the Salivette method were 0.035mgL -1 and 0.117mgL -1, respectively; whereas, 0.015mgL -1 (LOD) and 0.050mgL -1 (LOQ) were obtained for serum. Copyright © 2018 Elsevier B.V. All rights reserved.
Determination of element levels in human serum: Total reflection X-ray fluorescence applications
NASA Astrophysics Data System (ADS)
Majewska, U.; Łyżwa, P.; Łyżwa, K.; Banaś, D.; Kubala-Kukuś, A.; Wudarczyk-Moćko, J.; Stabrawa, I.; Braziewicz, J.; Pajek, M.; Antczak, G.; Borkowska, B.; Góźdź, S.
2016-08-01
Deficiency or excess of elements could disrupt proper functioning of the human body and could lead to several disorders. Determination of their concentrations in different biological human fluids and tissues should become a routine practice in medical treatment. Therefore the knowledge about appropriate element concentrations in human organism is required. The purpose of this study was to determine the concentration of several elements (P, S, Cl, K, Ca, Cr, Fe, Cu, Zn, Se, Br, Rb, Pb) in human serum and to define the reference values of element concentration. Samples of serum were obtained from 105 normal presumably healthy volunteers (66 women aged between 15 and 78 years old; 39 men aged between 15 and 77 years old). Analysis has been done for the whole studied population and for subgroups by sex and age. It is probably first so a wide study of elemental composition of serum performed in the case of Świętokrzyskie region. Total reflection X-ray fluorescence (TXRF) method was used to perform the elemental analysis. Spectrometer S2 Picofox (Bruker AXS Microanalysis GmbH) was used to identify and measure elemental composition of serum samples. Finally, 1st and 3rd quartiles were accepted as minimum and maximum values of concentration reference range.
NASA Astrophysics Data System (ADS)
Lin, Duo; Feng, Shangyuan; Pan, Jianji; Chen, Yanping; Lin, Juqiang; Sun, Liqing; Chen, Rong
2011-11-01
Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopic technique that is capable of probing the biomolecular changes associated with diseased transformation. The objective of our study was to explore gold nanoparticle based SERS to obtain blood serum biochemical information for non-invasive colorectal cancer detection. SERS measurements were performed on two groups of blood serum samples: one group from patients (n = 38) with pathologically confirmed colorectal cancer and the other group from healthy volunteers (control subjects, n = 45). Tentative assignments of the Raman bands in the measured SERS spectra suggested interesting cancer specific biomolecular changes, including an increase in the relative amounts of nucleic acid, a decrease in the percentage of saccharide and proteins contents in the blood serum of colorectal cancer patients as compared to that of healthy subjects. Principal component analysis (PCA) of the measured SERS spectra separated the spectral features of the two groups into two distinct clusters with little overlaps. Linear discriminate analysis (LDA) based on the PCA generated features differentiated the nasopharyngeal cancer SERS spectra from normal SERS spectra with high sensitivity (97.4%) and specificity (100%). The results from this exploratory study demonstrated that gold nanoparticle based SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of colorectal cancers.
NASA Astrophysics Data System (ADS)
Lin, Duo; Feng, Shangyuan; Pan, Jianji; Chen, Yanping; Lin, Juqiang; Sun, Liqing; Chen, Rong
2012-03-01
Surface-enhanced Raman spectroscopy (SERS) is a vibrational spectroscopic technique that is capable of probing the biomolecular changes associated with diseased transformation. The objective of our study was to explore gold nanoparticle based SERS to obtain blood serum biochemical information for non-invasive colorectal cancer detection. SERS measurements were performed on two groups of blood serum samples: one group from patients (n = 38) with pathologically confirmed colorectal cancer and the other group from healthy volunteers (control subjects, n = 45). Tentative assignments of the Raman bands in the measured SERS spectra suggested interesting cancer specific biomolecular changes, including an increase in the relative amounts of nucleic acid, a decrease in the percentage of saccharide and proteins contents in the blood serum of colorectal cancer patients as compared to that of healthy subjects. Principal component analysis (PCA) of the measured SERS spectra separated the spectral features of the two groups into two distinct clusters with little overlaps. Linear discriminate analysis (LDA) based on the PCA generated features differentiated the nasopharyngeal cancer SERS spectra from normal SERS spectra with high sensitivity (97.4%) and specificity (100%). The results from this exploratory study demonstrated that gold nanoparticle based SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of colorectal cancers.
de Brito, Naira Josele Neves; de Medeiros Rocha, Érika Dantas; de Araújo Silva, Alfredo; Costa, João Batista Sousa; França, Mardone Cavalcante; das Graças Almeida, Maria; Brandão-Neto, José
2014-01-01
The recognized antagonistic actions between zinc and iron prompted us to study this subject in children. A convenience sample was used. Thirty healthy children between 8 and 9 years of age were studied with the aim of establishing the effect of a 3-mo oral zinc supplementation on iron status. Fifteen individuals were given a placebo (control group), and 15 were given 10 mg Zn/day (experimental group). Blood samples were collected at 0, 60, 120, 180 and 210 min after a 12-h overnight fast, before and after placebo or zinc supplementation. This supplementation was associated with significant improvements in energy, protein, fat, carbohydrate, fiber, calcium, iron, and zinc intake in accordance with the recommendations for age and sex. The basal serum zinc concentration significantly increased after oral zinc supplementation (p < 0.001). However, basal serum iron concentrations and area under the iron curves significantly decreased in the experimental group (p < 0.0001) and remained at the same level throughout the 210-min study. The values obtained for hemoglobin, mean corpuscular volume, ferritin, transferrin, transferrin saturation, ceruloplasmin and total protein were within normal reference ranges. In conclusion, the decrease in serum iron was likely due to the effects of chronic zinc administration, and the decrease in serum iron was not sufficient to cause anemia. PMID:25192026
Reed, S M; Howe, D K; Morrow, J K; Graves, A; Yeargan, M R; Johnson, A L; MacKay, R J; Furr, M; Saville, W J A; Williams, N M
2013-01-01
Recent work demonstrated the value of antigen-specific antibody indices (AI and C-value) to detect intrathecal antibody production against Sarcocystis neurona for antemortem diagnosis of equine protozoal myeloencephalitis (EPM). The study was conducted to assess whether the antigen-specific antibody indices can be reduced to a simple serum : cerebrospinal fluid (CSF) titer ratio to achieve accurate EPM diagnosis. Paired serum and CSF samples from 128 horses diagnosed by postmortem examination. The sample set included 44 EPM cases, 35 cervical-vertebral malformation (CVM) cases, 39 neurologic cases other than EPM or CVM, and 10 non-neurologic cases. Antibodies against S. neurona were measured in serum and CSF pairs using the SnSAG2 and SnSAG4/3 (SnSAG2, 4/3) ELISAs, and the ratio of each respective serum titer to CSF titer was determined. Likelihood ratios and diagnostic sensitivity and specificity were calculated based on serum titers, CSF titers, and serum : CSF titer ratios. Excellent diagnostic sensitivity and specificity was obtained from the SnSAG2, 4/3 serum : CSF titer ratio. Sensitivity and specificity of 93.2 and 81.1%, respectively, were achieved using a ratio cutoff of ≤100, whereas sensitivity and specificity were 86.4 and 95.9%, respectively, if a more rigorous cutoff of ≤50 was used. Antibody titers in CSF also provided good diagnostic accuracy. Serum antibody titers alone yielded much lower sensitivity and specificity. The study confirms the value of detecting intrathecal antibody production for antemortem diagnosis of EPM, and they further show that the antigen-specific antibody indices can be reduced in practice to a simple serum : CSF titer ratio. Copyright © 2013 by the American College of Veterinary Internal Medicine.
de Araújo, Tais Pinheiro; Rodrigues, Sueli Guerreiro; Costa, Maria Irene Weyl de A; Vasconcelos, Pedro Fernando da Costa; da Rosa, Amélia P A Travassos
2002-01-01
From June to December 1999, 785 serum samples were obtained from patients clinically suspected of having dengue or yellow fever. The patients were referred by public health centers distributed within the six mesoregions of Par State, Brazil. Serum samples were tested for Flavivirus antibodies by hemagglutination inhibition test and for dengue and yellow fever viruses by enzyme-linked immunosorbent assay for IgM detection. Of the sera collected, 563 (71.7%) were positive by HI test and out of these 150 (26.6%) were positive by ELISA-IgM. Dengue virus was responsible for most of the recent infections in all regions; yellow fever cases detected in the current study were restricted to the Maraj and Southeast regions.
Wang, Qingqing; Rangiah, Kannan; Mesaros, Clementina; Snyder, Nathaniel W.; Vachani, Anil; Song, Haifeng; Blair, Ian A.
2015-01-01
An ultrasensitive stable isotope dilution liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for multiplexed quantitative analysis of six unconjugated and conjugated estrogens in human serum. The quantification utilized a new derivatization procedure, which formed analytes as pre-ionized N-methyl pyridinium-3-sulfonyl (NMPS) derivatives. This method required only 0.1 mL of human serum, yet was capable of simultaneously quantifying six estrogens within 20 min. The lower limit of quantitation (LLOQ) for estradiol (E2), 16α-hydroxy (OH)-E2, 4-methoxy (MeO)-E2 and 2-MeO-E2 was 1 fg on column, and was 10 fg on column for 4-OH-E2 and 2-OH-E2. All analytes demonstrated a linear response from 0.5 to 200 pg/mL (5–2000 pg/mL for 4-OH-E2 and 2-OH-E2). Using this validated method, the estrogen levels in human serum samples from 20 female patients and 20 male patients were analyzed and compared. The levels found for unconjugated serum E2 from postmenopausal women (mean 2.7 pg/mL) were very similar to those obtained by highly sensitive gas chromatography-mass spectrometry (GC-MS) methodology. However, the level obtained in serum from older men (mean 9.5 pg/mL) was lower than has been reported previously by both GC-MS and LC-MS procedures. The total (unconjugated + conjugated) 4-MeO-E2 levels were significantly higher in female samples compared with males (p<0.05). The enhanced sensitivity offered by the present method will allow for a more specific analysis of estrogens and their metabolites. Our observations might suggest that the level of total 4-MeO-E2 could be a potential biomarker for breast cancer cases. PMID:25637677
Trends in serum relaxin concentration among elite collegiate female athletes
Dragoo, Jason L; Castillo, Tiffany N; Korotkova, Tatiana A; Kennedy, Ashleigh C; Kim, Hyeon Joo; Stewart, Dennis R
2011-01-01
Purpose: This study was designed to investigate the relationship between serum relaxin concentration (SRC) and menstrual history and hormonal contraceptive use among elite collegiate female athletes. Evaluation of SRC in athletes is necessary, because relaxin has been associated with increased knee joint laxity and decreased anterior cruciate ligament (ACL) strength in animal models. Methods: National Collegiate Athletic Association Division I female athletes participating in sports at high risk for ACL tears – basketball, field hockey, gymnastics, lacrosse, soccer, and volleyball – were invited to participate. All participants completed a questionnaire about their menstrual history and hormonal contraceptive use. Venipuncture was performed to obtain samples of serum progesterone and relaxin. Samples were obtained during the mid-luteal phase from ovulating participants, and between the actual or projected cycle days 21 to 24, from anovulatory participants. Serum concentration of relaxin and progesterone was determined by ELISA and the data were analyzed using SPSS statistical software with significance set at P = 0.05. Results: 169 female athletes participated. The mean SRC among all participants was 3.08 ± 6.66 pg/mL). The mean SRC differed significantly between those participants using hormonal contraceptives (1.41 pg/mL) and those not using hormonal contraceptives (3.08 pg/mL, P = 0.002). Mean SRC was lowest among amenorrheic participants (1.02 pg/mL) and highest among oligomenorrheic participants (3.71 pg/mL) and eumenorrheic participants (3.06 pg/mL); these differences were not significant (P = 0.53). Mean serum progesterone concentration (SPC) differed significantly between those participants using hormonal contraceptives (2.80 ng/mL), and those not using hormonal contraceptives (6.99 ng/mL, P < 0.0001). Conclusions: There is a positive correlation between serum progesterone and SRC and an attenuation of SRC with hormonal contraceptive use. Our results underscore the significant role that hormonal contraceptives can play in decreasing relaxin levels, if future investigations establish a link between relaxin levels and ligamentous injury among female athletes. PMID:21339934
Spillane, Mike; Schwarz, Neil; Willoughby, Darryn S
2015-06-01
The purpose of the study was to determine the effect of single bouts of lower-body (LB) and upper- and lower-body (ULB) resistance exercise on serum testosterone concentrations and the effects on muscle testosterone, dihydrotestosterone (DHT), androgen receptor (AR) protein content, and AR-DNA binding. A secondary purpose was to determine the effects on serum wingless-type MMTV integration site (Wnt4) levels and skeletal muscle β-catenin content. In a randomized cross-over design, exercise bouts consisted of a LB and ULB protocol, and each bout was separated by 1 week. Blood and muscle samples were obtained before exercise and 3 and 24h post-exercise; blood samples were also obtained at 0.5, 1, and 2 h post-exercise. Statistical analyses were performed by separate two-way factorial analyses of variance (ANOVA) with repeated measures. No significant differences from baseline were observed in serum total and free testosterone and skeletal muscle testosterone and DHT with either protocol (p>0.05). AR protein was significantly increased at 3 h post-exercise and decreased at 24 h post-exercise for ULB, whereas AR-DNA binding was significantly increased at 3 and 24h post-exercise (p<0.05). In response to ULB, serum Wnt4 was significantly increased at 0.5, 1, and 2 h post-exercise (p<0.05) and β-catenin was significantly increased at 3 and 24 h post-exercise (p<0.05). It was concluded that, despite a lack of increase in serum testosterone and muscle androgen concentrations from either mode of resistance exercise, ULB resistance exercise increased Wnt4/β-catenin signaling and AR-DNA binding. Copyright © 2015 Elsevier Inc. All rights reserved.
Biernacka, Kinga; Karbowiak, Paweł; Wróbel, Paweł; Charęza, Tomasz; Czopowicz, Michał; Balka, Gyula; Goodell, Christa; Rauh, Rolf; Stadejek, Tomasz
2016-12-01
Recently oral fluid has become a novel sample type for pathogen nucleic acid and antibody detection, as it is easy to obtain with non-invasive procedures. The objective of the study was to analyze porcine reproductive and respiratory syndrome virus (PRRSV) and influenza A virus (IAV) circulation in growing pigs from three Polish production farms, using Real Time PCR and ELISA testing of oral fluid and serum. Oral fluids were collected every 2weeks, in the same 3-4 pens of pigs aged between 5 and 17weeks. Additionally, blood samples were collected every 4weeks from 4 pigs corresponding to the same pens as oral fluid and tested for the presence of PRRSV nucleic acid (pooled by 4) and antibodies. In farm A no PRRSV circulation was detected and only maternal antibodies were present. In farm B and farm C antibodies to PRRSV in serum and oral fluid were detected in most samples. In farm B PRRSV Type 1 was detected in 80.9% of oral fluid samples and in 58.3% of serum pools, and in farm C in 92.8% of oral fluid samples and 75% serum pools. Striking differences were observed between different pens in PRRSV detection patterns. In farms B and C ORF5 sequence analysis showed the presence of wild type strains which were about 84-85% identical to the modified live vaccine used. In all three farms two waves of IAV shedding with oral fluid were detected, in weaners and fatteners. Copyright © 2016 Elsevier Ltd. All rights reserved.
Depciuch, J; Parlinska-Wojtan, M
2018-02-20
Depression is a serious mental illness. To study the mechanism of depression and search for new, more effective therapies, animal models are often used. Unfortunately, none of the available models reflects all the symptoms of depression. Therefore researchers are looking for new tools to diagnose depression. Unfortunately, the nowadays-available depression diagnosis methods are only psychological tests. However, it is known, that the amount of phospholipids, proteins and lipids decreases during depression. Raman and FTIR (Fourier Transform Infra Red) spectroscopies provide information on the chemical compounds in the measured sample e.g. blood serum. These spectroscopic techniques may thus become reliable and accurate tools for evaluating changes in the amount of phospholipids and proteins in depression disease. In this study differences between dried and liquid blood serum samples of healthy and depressed individuals measured by Raman (range 0-3000cm -1 ) and FTIR (Fourier Transform Infrared) (range 900-3000cm -1 ) spectroscopy were evaluated. The resulting spectra and accurate analysis led to the conclusion that an appropriate measurement of the background and the elimination of peaks from water had the greatest impact on the reliability of the results. Furthermore, after detailed studies of FTIR and Raman spectra of dried and liquid blood serum samples, including a complete analysis of peaks after Kramers-Kröning (KK) transformation, it was found that the sample preparation did not affect the results obtained by Raman spectroscopy. In FTIR measurements only a minimal effect on peak intensity was observed. Copyright © 2017 Elsevier B.V. All rights reserved.
Park, Jaehyun; Jeon, Byongtae; Kang, Sungki; Oh, Mirae; Kim, Myonghwa; Jang, Seyoung; Park, Pyojam; Kim, Sangwoo; Moon, Sangho
2015-09-01
This study was conducted to investigate changes in blood enzyme parameters and to evaluate the relationship between insulin-like growth factor-1 (IGF-1), antler growth and body weight during the antler growth of sika deer (Cervus nippon). Serum enzyme activity and IGF-1 concentrations were measured in blood samples collected from the jugular and femoral veins at regular intervals during the antler growth period. Blood samples were taken in the morning from fasted stags (n = 12) which were healthy and showed no clinical signs of disease. Alfalfa was available ad libitum and concentrates were given at 1% of body weight to all stags. The experimental diet was provided at 9 am with water available at all times. There were no significant differences in alkaline phosphatase, aspartate aminotransferase, and alanine aminotransferase during antler growth, but alkaline phosphatase concentrations increased with antler growth progression, and the highest alkaline phosphatase concentration was obtained 55 days after antler casting. Serum IGF-1 concentrations measured from blood samples taken from the jugular vein during antler growth, determined that levels of IGF-1 was associated with body weight and antler growth patterns. Serum IGF-1 concentrations were higher at the antler cutting date than other sampling dates. Antler length increased significantly during antler growth (p<0.001), and there was a similar trend to between right and left beams. Body weight increased with antler growth but was not significant. Consequently it appeared that serum alkaline phosphatase concentration was related to antler growth and both antler growth and body weight were associated positively with IGF-1 concentrations during antler growth.
Borte, Stephan; Janzi, Magdalena; Pan-Hammarström, Qiang; von Döbeln, Ulrika; Nordvall, Lennart; Winiarski, Jacek; Fasth, Anders; Hammarström, Lennart
2012-01-01
There is a need for neonatal screening tools to improve the long-term clinical outcome of patients with primary immunodeficiency diseases (PID). Recently, a PCR-based screening method for both TRECs and KRECs using Guthrie card samples has been developed. However, the applicability of these excision circle assays is limited to patients with severe T or B cell lymphopenia (SCID, XLA and A-T), whereas the most common forms of PID are not detected. Absence of serum IgA is seen in a major fraction of patients with immunological defects. As serum IgA in newborns is considered to be of fetal origin, eluates from routinely collected dried blood spot samples might thus be suitable for identification of children with PID. To assess the applicability of such screening assays, stored Guthrie card samples were obtained from 47 patients with various forms of primary immunodeficiency diseases (SCID, XLA, A-T, HIGM and IgAD), 20 individuals with normal serum IgA levels born to IgA-deficient mothers and 51 matched healthy newborns. Surprisingly, normal serum IgA levels were found in all SCID, XLA, A-T and HIGM patients and, additionally, in all those IgAD patients born to IgA-sufficient mothers. Conversely, no serum IgA was found in any of the 16 IgAD patients born by IgA-deficient mothers. Moreover, half of the IgA-sufficient individuals born by IgA-deficient mothers also lacked IgA at birth whereas no IgA-deficient individuals were found among the controls. IgA in neonatal dried blood samples thus appears to be of both maternal and fetal origin and precludes its use as a reliable marker for neonatal screening of primary immunodeficiency diseases. PMID:22916257
Borte, Stephan; Janzi, Magdalena; Pan-Hammarström, Qiang; von Döbeln, Ulrika; Nordvall, Lennart; Winiarski, Jacek; Fasth, Anders; Hammarström, Lennart
2012-01-01
There is a need for neonatal screening tools to improve the long-term clinical outcome of patients with primary immunodeficiency diseases (PID). Recently, a PCR-based screening method for both TRECs and KRECs using Guthrie card samples has been developed. However, the applicability of these excision circle assays is limited to patients with severe T or B cell lymphopenia (SCID, XLA and A-T), whereas the most common forms of PID are not detected. Absence of serum IgA is seen in a major fraction of patients with immunological defects. As serum IgA in newborns is considered to be of fetal origin, eluates from routinely collected dried blood spot samples might thus be suitable for identification of children with PID. To assess the applicability of such screening assays, stored Guthrie card samples were obtained from 47 patients with various forms of primary immunodeficiency diseases (SCID, XLA, A-T, HIGM and IgAD), 20 individuals with normal serum IgA levels born to IgA-deficient mothers and 51 matched healthy newborns. Surprisingly, normal serum IgA levels were found in all SCID, XLA, A-T and HIGM patients and, additionally, in all those IgAD patients born to IgA-sufficient mothers. Conversely, no serum IgA was found in any of the 16 IgAD patients born by IgA-deficient mothers. Moreover, half of the IgA-sufficient individuals born by IgA-deficient mothers also lacked IgA at birth whereas no IgA-deficient individuals were found among the controls. IgA in neonatal dried blood samples thus appears to be of both maternal and fetal origin and precludes its use as a reliable marker for neonatal screening of primary immunodeficiency diseases.
Greenacre, C B; Young, D W; Behrend, E N; Wilson, G H
2001-11-01
To validate a novel high-sensitivity radioimmunoassay (RIA) procedure developed to accurately measure the relatively low serum total thyroxine (T4) concentrations of birds and reptiles and to establish initial reference ranges forT4 concentration in selected species of psittacine birds and snakes. 56 healthy nonmolting adult psittacine birds representing 6 species and 42 captive snakes representing 4 species. A solid-phase RIA designed to measure free T4 concentrations in dialysates of human serum samples was used without dialysis to evaluate total T4 concentration in treated samples obtained from birds and reptiles. Serum T4 binding components were removed to allow assay of undialyzed samples. Assay validation was assessed by determining recovery of expected amounts of T4 in treated samples that were serially diluted or to which T4 was added. Intra- and interassay coefficient of variation (CV) was determined. Mean recovery of T4 added at 4 concentrations ranged from 84.9 to 115.0% and 95.8 to 119.4% in snakes and birds, respectively. Intra- and interassay CV was 3.8 and 11.3%, respectively. Serum total T4 concentrations for 5 species of birds ranged from 2.02 to 768 nmol/L but ranged from 3.17 to 142 nmol/L for blue-fronted Amazon parrots; concentrations ranged from 0.21 to 6.06 nmol/L for the 4 species of snakes. This new RIA method provides a commercially available, accurate, and sensitive method for measurement of the relatively low serum T4 concentrations of birds and snakes. Initial ranges for the species evaluated were established.
Gresa-Arribas, Nuria; Titulaer, Maarten J; Torrents, Abiguei; Aguilar, Esther; McCracken, Lindsey; Leypoldt, Frank; Gleichman, Amy J; Balice-Gordon, Rita; Rosenfeld, Myrna R; Lynch, David; Graus, Francesc; Dalmau, Josep
2014-02-01
Anti-N-methyl-d-aspartate (NMDA) receptor encephalitis is a severe but treatable autoimmune disorder which diagnosis depends on sensitive and specific antibody testing. We aimed to assess the sensitivity and specificity of serum and CSF antibody testing in patients with anti-NMDA receptor encephalitis, and the relation between titres, relapses, outcome, and epitope repertoire. In this observational study, we used rat brain immunohistochemistry and cell-based assays (CBA) with fixed or live NMDA receptor-expressing cells to determine the sensitivity and specificity of antibody testing in paired serum and CSF samples. Samples were obtained at diagnosis from patients with anti-NMDA receptor encephalitis and from control participants worldwide. We deemed a patient to be antibody positive if their serum, their CSF, or both tested positive with both immunohistochemistry and CBA techniques; we determined titres with serial sample dilution using brain immunohistochemistry. We examined samples from 45 patients (25 with good outcome [modified Rankin Scale, mRS 0-2], ten with poor outcome [mRS 3-6], and ten with relapses) at three or more timepoints. We determined the epitope repertoire in the samples of 23 patients with CBA expressing GluN1-NMDA receptor mutants. We analysed samples from 250 patients with anti-NMDA receptor encephalitis and 100 control participants. All 250 patients had NMDA receptor antibodies in CSF but only 214 had antibodies in serum (sensitivity 100.0% [98.5-1000%] vs 85.6% [80.7-89.4%], p<0.0001). Serum immunohistochemistry testing was more often in agreement with CBA with fixed cells (77 [71%] of 108) than with CBA with live cells (63 [58%] of 108, p=0.0056). In multivariable analysis, CSF and serum titres were higher in patients with poor outcome than in those with good outcome (CSF dilution 340 vs 129, difference 211, [95% CI 1-421], p=0.049; serum dilution 7370 vs 1243, difference 6127 [2369-9885], p=0.0025), and in patients with teratoma than in those without teratoma (CSF 395 vs 110, difference 285 [134-437], p=0.0079; serum 5515 vs 1644, difference 3870 [548-7193], p=0.024). Over time there was a decrease of antibody titres in the 35 patients with good or poor outcome and samples followed at three timepoints regardless of outcome (from diagnosis to last follow-up: CSF 614 to 76, difference 538 [288-788]; serum 5460 to 1564, difference 3896 [2428-5362]; both p<0.0001). Relapses were associated with a change in titre more often in CSF than in serum (14 of 19 vs seven of 16, p=0.037). After recovery, 24 of 28 CSF samples and 17 of 23 serum samples from patients remained antibody positive. Patients' antibodies targeted a main epitope region at GluN1 aminoacid 369; the epitope repertoire did not differ between patients with different outcomes, and did not change during relapses. The sensitivity of NMDA receptor antibody testing is higher in CSF than in serum. Antibody titres in CSF and serum were higher in patients with poor outcome or teratoma than in patients with good outcome or no tumour. The titre change in CSF was more closely related with relapses than was that in serum. These findings emphasise the importance of including CSF in antibody studies, and that antibody titres can complement clinical assessments. Dutch Cancer Society, National Institutes of Health, McKnight Neuroscience of Brain Disorders award, the Fondo de Investigaciones Sanitarias, ErasmusMC fellowship, and Fundació la Marató de TV3. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kobayashi, Tsuneo
2018-03-01
Diagnosis using a specific tumor marker is difficult because the sensitivity of this detection method is under 20%. Herein, a tumor marker combination assay, combining growth-related tumor marker and associated tumor marker (Cancer, 73(7), 1994), was employed. This double-blind tumor marker combination assay (TMCA) showed 87.5% sensitivity as the results, but a low specificity, ranging from 30 to 76%. To overcome this low specificity, we exploited complex markers, a multivariate analysis and serum fractionation by biochemical biopsy. Thus, in this study, a combination of new techniques was used to re-evaluate these serum samples. Three serum panels, containing 90, 120, and 97 samples were obtained from the Mayo Clinic. The final results showed 80-90% sensitivity, 84-85% specificity, and 83-88% accuracy. We demonstrated a notable tumor marker combination assay with high accuracy. This TMCA should be applicable for primary cancer detection and recurrence prevention. © 2018 The Author. Cancer Medicine published by John Wiley & Sons Ltd.
Andreasen, C B; Pearson, E G; Smith, B B; Gerros, T C; Lassen, E D
1998-04-01
Fifty clinically healthy llamas, 0.5-13 years of age (22 intact males, 10 neutered males, 18 females), with no biochemical evidence of liver disease or hematologic abnormalities, were selected to establish serum bile acid reference intervals. Serum samples submitted to the clinical pathology laboratory were analyzed using a colorimetric enzymatic assay to establish bile acid reference intervals. A nonparametric distribution of llama bile acid concentrations was 1-23 micromol/liter for llamas >1 year of age and 10-44 micromol/liter for llamas < or = 1 year of age. A significant difference was found between these 2 age groups. No correlation was detected between gender and bile acid concentrations. The reference intervals were 1.1-22.9 micromol/liter for llamas >1 year of age and 1.8-49.8 micromol/liter for llamas < or = 1 year of age. Additionally, a separate group of 10 healthy adult llamas (5 males, 5 females, 5-11 years of age) without biochemical or hematologic abnormalities was selected to assess the effects of feeding and time intervals on serum bile acid concentrations. These 10 llamas were provided fresh water and hay ad libitum, and serum samples were obtained via an indwelling jugular catheter hourly for 11 hours. Llamas were then kept from food overnight (12 hours), and subsequent samples were taken prior to feeding (fasting baseline time, 23 hours after trial initiation) and postprandially at 0.5, 1, 2, 4, and 8 hours. In feeding trials, there was no consistent interaction between bile acid concentrations and time, feeding, or 12-hour fasting. Prior feeding or time of day did not result in serum bile acid concentrations outside the reference interval, but concentrations from individual llamas varied within this interval over time.
Influence of time, temperature and coagulation on the measurement of C3, C3 split products and C4.
Sinosich, M J; Teisner, B; Brandslund, I; Fisher, M; Grudzinskas, J G
1982-11-26
Quantitative and qualitative immunoelectrophoretic analyses of circulating C3, C3 split products and C4 were performed in matched EDTA plasma and serum obtained from 5 normal subjects and stored for up to 48 h at room temperature (18 degrees C-22 degrees C) and 4 degrees C. Fluctuations in apparent levels of C3 were greater in serum than plasma stored at room temperature, a fall in levels seen by 24 h being followed by a significant increase. By contrast, levels of C3 did not alter if stored at 4 degrees C. C4 levels in both EDTA plasma and serum remained unchanged for 24 h, a slight decrease being seen at 48 h. Levels of C4 remained constant if samples were stored at 4 degrees C. Crossed immunoelectrophoresis revealed a significant progressive decrease in C3 levels and a simultaneous increase in C3c occurring after 4 h in serum and 8 h in EDTA plasma, stored at room temperature. In studies conducted at 4 degrees C, similar but delayed fluctuations were seen. A progressive and significant increase in C3d levels was seen in both plasma and serum samples stored at room temperature, levels rising to 276% (plasma) and 308% (serum) of levels seen at zero time. At 4 degrees C marginal increases in C3d levels only were observed. These results suggest that in vitro degradation of C3 and C4 are readily facilitated by temperature, time and coagulation, and that conditions of collection and storage of samples must be optimized for the accurate definition of activation of the complement cascade.
Simultaneous quantitation of multiple contraceptive hormones in human serum by LC-MS/MS.
Blue, Steven W; Winchell, Andrea J; Kaucher, Amy V; Lieberman, Rachel A; Gilles, Christopher T; Pyra, Maria N; Heffron, Renee; Hou, Xuanlin; Coombs, Robert W; Nanda, Kavita; Davis, Nicole L; Kourtis, Athena P; Herbeck, Joshua T; Baeten, Jared M; Lingappa, Jairam R; Erikson, David W
2018-04-01
The objective was to develop a method to simultaneously quantify five commonly used hormonal contraceptives (HCs) and two endogenous sex steroids by liquid chromatography-tandem triple quadrupole mass spectrometry (LC-MS/MS) and apply this method to human serum samples. We developed a method to simultaneously analyze ethinyl estradiol (EE2), etonogestrel (ENG), levonorgestrel (LNG), medroxyprogesterone acetate (MPA) and norethisterone (NET), along with estradiol (E2) and progesterone (P4), in human serum for a Shimadzu Nexera-LCMS-8050 LC-MS/MS platform. We analyzed serum collected from women self-reporting use of oral contraceptives, contraceptive implants or injectable contraceptives (n=14) and normally cycling women using no HC (n=15) as well as pooled samples from women administered various HCs (ENG, n=6; LNG, n=14; MPA, n=7; NET, n=5). Limits of quantitation were 0.010ng/mL for E2, EE2 and P4; 0.020ng/mL for ENG, LNG and MPA; and 0.040ng/mL for NET. Precisions for all assays, as indicated by coefficient of variation, were less than or equal to 12.1%. Accuracies for all assays were in the range of 95%-108%. Endogenous hormone values obtained from analysis of human serum samples are in agreement with levels previously reported in the literature for normally cycling women as well as for women taking the appropriate HC. We have developed a robust, accurate and sensitive method for simultaneously analyzing commonly used contraceptive steroids and endogenous sex steroids in human serum. This analytical method can be used for quantitating contraceptive steroid levels in women for monitoring systemic exposure to determine drug interactions, nonadherence, misreporting and proper dosing. Copyright © 2018 Elsevier Inc. All rights reserved.
Klohonatz, Kristin M; Cameron, Ashely D; Hergenreder, Joanna R; da Silveira, Juliano C; Belk, Aeriel D; Veeramachaneni, D N R; Bouma, Gerrit J; Bruemmer, Jason E
2016-12-01
During early pregnancy, the conceptus and mare communicate to establish pregnancy. Cell-secreted vesicles (e.g., exosomes) have been reported in serum. Exosomes contain bioactive materials, such as miRNA, that can mediate cell responses. We hypothesized that a) exosomes are present in mare circulation and quantity varies with pregnancy status, b) exosomes contain miRNAs unique to pregnancy status, and c) miRNAs target pathways in endometrium based upon pregnancy status of the mare. First, serum samples were obtained from mares in a crossover design, with each mare providing samples from a pregnant and nonmated control cycle (n = 3/sample day) on Days 12, 14, 16, and 18 postovulation. Flow cytometry revealed the presence of serum microvesicles in mares in two different-sized populations (greater than or less than 100 nm), validated by transmission electron microscopy. Second, serum was collected on Days 9, 11, and 13 (n = 4/day), and endometrial biopsies were collected on Days 11 and 13 (n = 3/day) from pregnant and nonmated mares. Total RNA from serum exosomes was evaluated with quantitative RT-PCR using equine-specific miRNA sequences. A total of 12 miRNAs were found in different quantities on the specified days. Pathway analysis suggested that miRNAs targeted focal adhesion molecules (FAMs). Transcripts corresponding to FAMs were evaluated in endometrial biopsies. Protein levels and localization for PAK6 and RAF1 were further evaluated. Our data suggest that serum exosomes contain miRNA that differ based upon pregnancy status, and may affect mRNA expression related to focal adhesion pathway in the endometrium, with a potential role in maternal recognition of pregnancy. © 2016 by the Society for the Study of Reproduction, Inc.
Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares
2017-01-01
Background The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo’s national surveillance for routine diagnosis were selected for this study. Methods The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory’s standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer’s instructions. Results The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory’s standard methodology, results showed high concordance, with Kappa index ranges of 0.9877–1.00 for CSF, and 0.8004–1.00 for serum samples. Conclusion The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost. PMID:28235065
Thiazide increases serum calcium in anuric patients: the role of parathyroid hormone.
Vasco, Raquel F V; Reis, Eduardo T; Moyses, Rosa M A; Elias, Rosilene M
2017-12-01
We evaluated the effect of hydrochlorothiazide in a sample of anuric patients on hemodialysis and found an increase in serum calcium, which occurred only in those with parathyroid hormone >300 pg/ml. This finding highlights the extra-renal effect of this diuretic and a possible role of parathyroid hormone in the mechanism. Thiazide diuretics are commonly used in patients with chronic kidney disease to treat hypertension. Their effects on calcium and bone metabolism are not well established, once calciuria may not fully explain levels of calcium and parathyroid hormone (PTH) in this population. A previous study has suggested that thiazides require the presence of PTH as a permissive condition for its renal action. In anuric patients, however, the role of PTH, if any, in the thiazide effect is unknown. To assess thiazide extra renal effect on serum calcium and whether such an effect is reliant on PTH, hydrochlorothiazide (HCTZ) 100 mg was given orally once a day to a sample of 19 anuric patients on hemodialysis for 2 weeks. Laboratories' analyses were obtained in three phases: baseline, after diuretic use, and after a 2-week washout phase. We demonstrated that serum calcium (Ca) increased in ten patients (52.6%) after HCTZ use, returning to previous levels after the washout period. Out of the 19 patients, ten presented PTH ≥ 300 pg/ml, and Ca has increased in eight of them, whereas in the other nine patients with PTH < 300 pg/ml, serum Ca has increased only in two individuals (RR risk of increase Ca 3.9; p = 0.012). HCTZ was capable of increasing serum Ca in a sample of anuric patients on hemodialysis and seems this effect is highly dependent on PTH levels. Caution is required while interpreting this result, as the small sample size might implicate in a finding caused by chance.
Voge, Natalia V.; Perera, Rushika; Mahapatra, Sebabrata; Gresh, Lionel; Balmaseda, Angel; Loroño-Pino, María A.; Hopf-Jannasch, Amber S.; Belisle, John T.; Harris, Eva; Blair, Carol D.; Beaty, Barry J.
2016-01-01
Background Epidemic dengue fever (DF) and dengue hemorrhagic fever/dengue shock syndrome (DHF/DSS) are overwhelming public health capacity for diagnosis and clinical care of dengue patients throughout the tropical and subtropical world. The ability to predict severe dengue disease outcomes (DHF/DSS) using acute phase clinical specimens would be of enormous value to physicians and health care workers for appropriate triaging of patients for clinical management. Advances in the field of metabolomics and analytic software provide new opportunities to identify host small molecule biomarkers (SMBs) in acute phase clinical specimens that differentiate dengue disease outcomes. Methodology/Principal Findings Exploratory metabolomic studies were conducted to characterize the serum metabolome of patients who experienced different dengue disease outcomes. Serum samples from dengue patients from Nicaragua and Mexico were retrospectively obtained, and hydrophilic interaction liquid chromatography (HILIC)-mass spectrometry (MS) identified small molecule metabolites that were associated with and statistically differentiated DHF/DSS, DF, and non-dengue (ND) diagnosis groups. In the Nicaraguan samples, 191 metabolites differentiated DF from ND outcomes and 83 differentiated DHF/DSS and DF outcomes. In the Mexican samples, 306 metabolites differentiated DF from ND and 37 differentiated DHF/DSS and DF outcomes. The structural identities of 13 metabolites were confirmed using tandem mass spectrometry (MS/MS). Metabolomic analysis of serum samples from patients diagnosed as DF who progressed to DHF/DSS identified 65 metabolites that predicted dengue disease outcomes. Differential perturbation of the serum metabolome was demonstrated following infection with different DENV serotypes and following primary and secondary DENV infections. Conclusions/Significance These results provide proof-of-concept that a metabolomics approach can be used to identify metabolites or SMBs in serum specimens that are associated with distinct DENV infections and disease outcomes. The differentiating metabolites also provide insights into metabolic pathways and pathogenic and immunologic mechanisms associated with dengue disease severity. PMID:26913918
Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Sun, Xuefei; Gao, Yuqian
2013-07-05
We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50-100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion and the multiplexing potential of this technique. Limits of quantification (LOQs) at low ng/mL levels with a medianmore » CV of ~12% were achieved for proteins spiked into human female serum using as little as 2 µL serum. PRISM-SRM provided up to ~1000-fold improvement in the LOQ when compared to conventional SRM measurements. Multiplexing capability of PRISM-SRM was also evaluated by two sets of serum samples with 6 and 21 target peptides spiked at the low attomole/µL levels. The results from SRM measurements for pooled or post-concatenated samples were comparable to those obtained from individual peptide fractions in terms of signal-to-noise ratios and SRM peak area ratios of light to heavy peptides. PRISM-SRM was applied to measure several ng/mL-level endogenous plasma proteins, including prostate-specific antigen, in clinical patient sera where correlation coefficients > 0.99 were observed between the results from PRISM-SRM and ELISA assays. Our results demonstrate that PRISM-SRM can be successfully used for quantification of low-abundance endogenous proteins in highly complex samples. Moderate throughput (50 samples/week) can be achieved by applying the post-concatenation or fraction multiplexing strategies. We anticipate broad applications for targeted PRISM-SRM quantification of low-abundance cellular proteins in systems biology studies as well as candidate biomarkers in biofluids.« less
Lorusso, Alessio; Baba, Doumbia; Spedicato, Massimo; Teodori, Liana; Bonfini, Barbara; Marcacci, Maurilia; Di Provvido, Andrea; Isselmou, Katia; Marini, Valeria; Carmine, Irene; Scacchia, Massimo; Di Sabatino, Daria; Petrini, Antonio; Bezeid, Beyatt Ahmed; Savini, Giovanni
2016-06-01
In March 2013, EDTA-blood and serum samples were collected from 119 cattle and 159 dromedaries at the slaughterhouse of Nouakchott, the capital city of the Islamic Republic of Mauritania. Serum samples were screened for the presence of Bluetongue (BT) antibodies by competitive ELISA (cELISA). Positive samples were then tested by serum-neutralization (SN) to determine BTV serotype. RNA from blood samples was first tested by a genus-specific quantitative RT-PCR assay which is able to detect all 27 existing BTV serotypes (RT-qPCR1-27). Positive samples were further screened by a RT-qPCR assay which, instead, is able to detect the classical 24 BTV serotypes only (RT-qPCR1-24). Of the 278 serum samples tested, 177 (mean=63.7%; 95% CI: 57.9%-69.1%) resulted positive by cELISA. Of these, 69 were from cattle (mean=58.0%; 95% CI: 49.0%-66.5%) and 108 from dromedaries (mean=67.9%; 95% CI: 60.3%-74.7%). BTV-26 neutralizing antibodies were by far the most frequently found as they were detected in 146 animals with titres ranging from 1:10 to 1:80. Out of 278 blood samples, 25 (mean=9.0%; 95% CI: 6.2%-12.9%) were found positive for BTV by RT-qPCR1-27, 20 (mean=16.8%; 95% CI: 11.2%-24.6%) were from cattle and 5 (mean=3.1%; 95% CI: 1.4%-7.1%) from dromedaries. When tested by RT-qPCR1-24 the 25 BTV positive samples were negative. Unfortunately, no genetic information by molecular typing or by next generation sequencing has been obtained as for the very low levels of RNA in the blood samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Sauter, Edward R; Tichansky, David S; Chervoneva, Inna; Diamandis, Eleftherios P
2002-01-01
Preliminary evidence has associated testosterone and prostate-specific antigen (PSA) with breast cancer. Our objective was to determine whether a) testosterone levels in nipple aspirate fluid (NAF), serum, or breast tissue are associated with breast cancer; b) testosterone levels in serum are associated with levels in NAF; c) PSA in NAF, serum, or breast tissue is associated with breast cancer; and d) serum PSA is associated with NAF PSA levels. We obtained 342 NAF specimens from 171 women by means of a modified breast pump. Additionally, we collected 201 blood samples from 99 women and 51 tissue samples from 41 subjects who underwent surgical resection for suspected disease. Women currently using birth control pills or hormone replacement therapy were excluded from the study. Controlling for age and menopausal status, serum testosterone was significantly increased in women with breast cancer (p = 0.002). NAF and serum testosterone levels were not associated. Neither NAF nor tissue testosterone was associated with breast cancer. Controlling for menopausal status and age, NAF PSA was significantly decreased in women with breast cancer (p < 0.001). We did not find serum PSA to be associated with breast cancer, although we found an indication that, in postmenopausal women, its levels were lower in women with cancer. Serum PSA was associated with NAF PSA in postmenopausal women (p < 0.001). PSA levels in cancerous tissue were significantly lower than in benign breast specimens from subjects without cancer (p = 0.011), whereas levels of PSA in histologically benign specimens from subjects with cancer were intermediate. Our results suggest that serum testosterone is increased and NAF PSA is decreased in women with breast cancer, with PSA expression being higher in normal than in cancerous breast tissues. NAF and serum PSA levels in postmenopausal women are correlated, suggesting that as laboratory assessment of PSA becomes more sensitive, serum PSA may become useful in identifying women with breast cancer. PMID:11882474
Piñeiro, Matilde; Morales, Joaquín; Vizcaíno, Elena; Murillo, José Alberto; Klauke, Thorsten; Petersen, Brigitte; Piñeiro, Carlos
2013-11-01
The serum concentration of acute phase proteins (APPs) increases in the presence of disease or stress, which makes APPs notable parameters for the global assessment of animal health and welfare. A rapid, immunochromatographic test (ICT) for the detection of elevated levels of pig Major Acute-phase Protein (pig-MAP), one of the main APPs in pigs, was evaluated in more than 1400 pig serum samples obtained from commercial farms. The ICT showed a good performance with a relative sensitivity (Sn) and specificity (Sp) of 94 and 97%, respectively, for a threshold of 1.5mg/mL (comparison with ELISA). Differences in the pig-MAP levels and the number of positive samples with the ICT were observed within the season of sampling, farms, and age groups at one farm, according to the presence of disease or lesions. The ICT was also evaluated in blood samples obtained at slaughter in association with the carcase inspection. The results from this study indicate that the ICT may be used for the evaluation of groups of pigs, after analysing one sub-sample of these pigs, and might be a useful tool in routine health and welfare monitoring programmes aimed to improve the quality of pig production. Copyright © 2013 Elsevier Ltd. All rights reserved.
Human herpesvirus 8 infection among various population groups in southern Israel.
Margalith, Miriam; Chatlynne, Louise G; Fuchs, Efrat; Owen, Carole; Lee, Cheng-Rei Ruth; Yermiyahu, Tikva; Whitman, James E; Ablashi, Dharam V
2003-12-15
To compare the prevalence of antibodies to human herpesvirus 8 (HHV-8) or Kaposi sarcoma-associated herpesvirus among Israeli and Ethiopian subjects. Serum samples were obtained from 98 Israeli Jewish students aged 18-30 years, 100 HIV-1-seronegative Ethiopian immigrants to Israel of the same age, and 100 HIV-1-seronegative Ethiopian children 1-12 years old upon their arrival in southern Israel. Plasma samples were obtained from 3 hospitalized patients with multicentric Castleman disease (MCD) as positive controls. All serum samples were tested for antibodies to both latent and lytic antigens. Antibodies to the lytic antigens and the latency-associated nuclear antigen (LANA) of HHV-8 were detected by enzyme linked immunosorbent assay and by immunofluorescence assay. HHV-8 DNA from serum or plasma samples was detected by polymerase chain reaction analysis. Antibodies to HHV-8 LANA were detected in 2.9% of the Israeli subjects aged 18-30 years and in 26% of the Ethiopian subjects from both age groups tested. Antibodies to the lytic antigens were detected in all 3 MCD patients, in 4% of the Ethiopian children, and in 2% of the 18- to 30-year-old Ethiopians. No antibodies to the lytic antigens were detected in the Israeli students. HHV-8 DNA was detected in all 3 MCD patients and in 2 of 4 of the Ethiopian children positive for the lytic antigens. HHV-8 is highly prevalent in Ethiopian immigrants to Israel as compared with Israeli students. Antibodies to HHV-8 in Ethiopia are acquired before puberty. The results of this study indicate the association of HHV-8 with MCD, as has been documented by many other researchers.
Böttger, Roland; Hoffmann, Ralf; Knappe, Daniel
2017-01-01
Proteolytic degradation of peptide-based drugs is often considered as major weakness limiting systemic therapeutic applications. Therefore, huge efforts are typically devoted to stabilize sequences against proteases present in serum or plasma, obtained as supernatants after complete blood coagulation or centrifugation of blood supplemented with anticoagulants, respectively. Plasma and serum are reproducibly obtained from animals and humans allowing consistent for clinical analyses and research applications. However, the spectrum of active or activated proteases appears to vary depending on the activation of proteases and cofactors during coagulation (serum) or inhibition of such enzymes by anticoagulants (plasma), such as EDTA (metallo- and Ca2+-dependent proteases) and heparin (e.g. thrombin, factor Xa). Here, we studied the presumed effects on peptide degradation by taking blood via cardiac puncture of CD-1 mice using a syringe containing a peptide solution. Due to absence of coagulation activators (e.g. glass surfaces and damaged cells), visible blood clotting was prevented allowing to study peptide degradation for one hour. The remaining peptide was quantified and the degradation products were identified using mass spectrometry. When the degradation rates (half-life times) were compared to serum derived freshly from the same animal and commercial serum and plasma samples, peptides of three different families showed indeed considerably different stabilities. Generally, peptides were faster degraded in serum than in plasma, but surprisingly all peptides were more stable in fresh blood and the order of degradation rates among the peptides varied among the six different incubation experiments. This indicates, that proteolytic degradation of peptide-based therapeutics may often be misleading stimulating efforts to stabilize peptides at degradation sites relevant only in vitro, i.e., for serum or plasma stability assays, but of lower importance in vivo.
Detection of hepatitis E virus RNA in saliva for diagnosis of acute infection.
Rivero-Juarez, A; Frias, M; Lopez-Lopez, P; Martinez-Peinado, A; Risalde, M Á; Brieva, T; Machuca, I; Camacho, Á; García-Bocanegra, I; Gomez-Villamandos, J C; Rivero, A
2018-04-16
Diagnosis of acute hepatitis E virus (HEV) infection is established by detection of anti-HEV IgM antibodies by ELISA or by amplification of serum viral RNA. Here, we evaluate the diagnostic value of testing HEV RNA in saliva to identify patients with acute HEV infection. Prospective proof-of-concept study including patients with acute hepatitis. Whole blood and neat saliva samples were obtained from all patients. Saliva samples were processed and analysed for HEV RNA by RT-PCR within 2 hr after collection. A total of 34 patients with acute hepatitis and 12 healthy donors were included in the study. HEV RNA in serum was confirmed by RT-PCR in eight of these patients (23.5%; 95% CI: 12.2%-40.2%). HEV was isolated in the saliva of eight of 34 patients (23.5%; 95% CI: 12.2%-40.2%). All patients with HEV RNA amplified in saliva had detectable HEV RNA in serum. HEV was isolated neither in the saliva of any of the 26 patients without detectable HEV RNA in serum nor in healthy donors. Our study suggests that acute HEV infection could be diagnosed by assessing viral load in saliva. © 2018 Blackwell Verlag GmbH.
NASA Astrophysics Data System (ADS)
Cheng, Jin-ying; Xu, Liang; Lü, Guo-dong; Tang, Jun; Mo, Jia-qing; Lü, Xiao-yi; Gao, Zhi-xian
2017-01-01
A Raman spectroscopy method combined with neural network is used for the invasive and rapid detection of echinococcosis. The Raman spectroscopy measurements are performed on two groups of blood serum samples, which are from 28 echinococcosis patients and 38 healthy persons, respectively. The normalized Raman reflection spectra show that the reflectivity of the echinococcosis blood serum is higher than that of the normal human blood serum in the wavelength ranges of 101—175 nm and 1 801—2 701 nm. Then the principal component analysis (PCA) and back propagation neural network (BPNN) model are used to obtain the diagnosis results. The diagnosis rates for healthy persons and echinococcosis persons are 93.333 3% and 90.909 1%, respectively, so the average final diagnosis rate is 92.121 2%. The results demonstrate that the Raman spectroscopy analysis of blood serum combined with PCA-BPNN has considerable potential for the non-invasive and rapid detection of echinococcosis.
Evaluation of pre transplant T-cell activation status by soluble CD 30 determination.
Abbas, Khawar; Muzaffar, Rana; Zafar, Mirza Naqi; Mubarak, Muhammad; Naqvi, Syed Ali Anwar; Rizvi, Syed Adibul Hassan
2009-04-01
To evaluate the utility of serum CD30 (sCD30) levels as predictor of early acute graft rejection in live related renal transplant programme. This prospective study included 50 consecutive renal transplant recipients who received their first live related renal allograft at the Sindh Institute of Urology and Transplantation (SIUT) between October 2006 and March 2007. Blood samples were obtained one day before transplantation and on the third and fourteenth posttransplant days. Blood samples were also obtained from 50, age and sex matched healthy control individuals. Levels of serum sCD30 were measured by Enzyme Linked Immunosorbent Assay (ELISA). Donor-recipient blood group matching was identical in all patients. Pre-transplant lymphocyte crossmatch for T and B cells was negative, and panel reactive antibodies (PRA) were 0% for all recipients. The mean age of recipients was 31.6 +/- 10.23 years (range 5 to 55 years), while mean donor age was 32.74 +/- 8.48 years (range 21-50 years). Eleven (22%) recipients and donors were HLA identical while remaining (78%) were one haplotype match. Average serum sCD30 pre-transplant levels (37.8 +/- 4.97U/ml) were significantly higher than those of healthy individual's mean value of 8.48 +/- 4.97 U/ml, (P = 0.001). Eight (16%) patients developed acute rejection episode during this follow up period. Rejections were described and classified according to BANFF 97 classification. In this small single center study the serum levels of sCD30 did not show any significant difference between rejection and non rejection group in our transplant population.
Judd, W J; Barnes, B A; Steiner, E A; Oberman, H A; Averill, D B; Butch, S H
1986-01-01
Direct antiglobulin tests (DATs) using anti-IgG were performed on 65,049 blood samples from prospective transfusion recipients; 3570 tests (5.49%) were positive. Using criteria published previously (primarily excluding patients not transfused within the preceding 14 days), 778 samples from other than neonatal patients were selected for further evaluation. Eluates that did not react were obtained on 518 (66.6%) of these samples. Warm-reactive autoantibodies were apparent in 192 eluates, while 16 contained drug-related antibodies, anti-A or anti-B from prior transfusion with ABO mismatched blood components, or anti-D passively acquired from immune serum globulin. Fifty-two eluates contained alloantibodies; however, in only six of these cases did the corresponding serum lack unexpected alloantibodies, as determined by routine pretransfusion studies. Three additional weakly reactive clinically significant alloantibodies were detected solely through additional serum tests performed on DAT-positive samples. On the basis of these findings, the DAT had a low predictive value when used to detect the early manifestations of an immune response to recently transfused red cells. Elimination of the autocontrol from routine pretransfusion testing, therefore, carries minimal risk to patients yet will undoubtedly contribute to the containment of health care costs. Moreover, the risk is lower than that associated with the elimination of the antiglobulin crossmatch.
Oikonomou, G; Trojacanec, P; Ganda, E K; Bicalho, M L S; Bicalho, R C
2014-07-01
The main objective of this study was to investigate the association between digital cushion thickness and sole temperature measured by infrared thermography. Data were collected from 216 lactating Holstein cows at 4 to 10d in milk (DIM). Cows were locomotion scored and sole temperature was measured after claw trimming (a minimum delay of 3 min was allowed for the hoof to cool) using an infrared thermography camera. Temperature was measured at the typical ulcer site of the lateral digit of the left hind foot. Immediately after the thermographic image was obtained, the thickness of the digital cushion was measured by ultrasonography. Rumen fluid samples were collected with a stomach tube and sample pH was measured immediately after collection. Additionally, a blood sample was obtained and used for measurements of serum concentrations of β-hydroxybutyrate (BHBA), nonesterified fatty acids (NEFA), and haptoglobin. To evaluate the associations of digital cushion thickness with sole temperature, a linear regression model was built using the GLIMMIX procedure in SAS software (SAS Institute Inc., Cary, NC). Sole temperature was the response variable, and digital cushion thickness quartiles, locomotion score group, rumen fluid pH, rumen fluid sample volume, environmental temperature, age in days, and serum levels of NEFA, BHBA, and haptoglobin were fitted in the model. Only significant variables were retained in the final model. Simple linear regression scatter plots were used to illustrate associations between sole temperature (measured by infrared thermography at the typical ulcer site) and environmental temperature and between NEFA and BHBA serum levels and haptoglobin. One-way ANOVA was used to compare rumen fluid pH for different locomotion score groups and for different digital cushion quartiles. Results from the multivariable linear regression model showed that sole temperature increased as locomotion scores increased and decreased as digital cushion thickness increased. These results were adjusted for environmental temperature, which was significantly associated with sole temperature. Serum levels of NEFA, BHBA, and haptoglobin were not associated with sole temperature. However, significant correlations existed between serum levels of NEFA and haptoglobin and between serum levels of BHBA and haptoglobin. Rumen fluid pH was not associated with either locomotion score or digital cushion thickness. In conclusion, we show here that digital cushion thickness was associated with sole temperature in cows at 4 to 10 DIM. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Evaluation of thyroid function in dogs suffering from recurrent flank alopecia.
Daminet, S; Paradis, M
2000-01-01
Thyroid function was assessed in euthyroid dogs (n = 20), dogs suffering from canine recurrent flank alopecia (CRFA, n = 18), and hypothyroid dogs (n = 21). Blood samples obtained from all dogs in each group were assayed for total thyroxine (TT4), thyrotropin (TSH), and thyroglobulin autoantibody (TgAA) serum concentrations. Total T4 and TSH serum concentrations were significantly decreased and increased, respectively, in the hypothyroid group compared with the other 2 groups. No significant differences in TT4 and TSH serum values were found between the euthyroid and CRFA groups. Thyroglobulin autoantibodies were detected in 10, 11.1, and 61.9% of euthyroid dogs, dogs with CRFA, and hypothyroid dogs, respectively. In conclusion, dogs suffering from CRFA have a normal thyroid function, and the determination of TT4 and TSH serum concentrations allows differentiation of these dogs from dogs with hypothyroidism, in most cases. Occasionally, the 2 diseases can be concomitant. PMID:10992988
Barker, Tyler; Rogers, Victoria E; Levy, Mark; Templeton, Jenna; Goldfine, Howard; Schneider, Erik D; Dixon, Brian M; Henriksen, Vanessa T; Weaver, Lindell K
2015-02-01
The purpose of this study was to determine if vitamin D status before supplementation influences the cytokine response after supplemental vitamin D. Forty-six reportedly healthy adults (mean(SD); age, 32(7) y; body mass index (BMI), 25.3(4.5) kg/m(2); serum 25-hydroxyvitamin D (25(OH)D), 34.8(12.2) ng/mL) were randomly assigned (double blind) to one of three groups: (1) placebo (n=15), or supplemental vitamin D (cholecalciferol) at (2) 4000 (n=14) or (3) 8000IU (n=17). Supplements were taken daily for 35days. Fasting blood samples were obtained before (Baseline, Bsl) and 35-days after (35-d) supplementation. Serum 25(OH)D, 1,25-dihydroxyvitamin D (1,25(OH)D), cytokines, and intact parathyroid hormone with calcium were measured in each blood sample. Supplemental vitamin D increased serum 25(OH)D (4000IU, ≈29%; 8000IU, ≈57%) and 1,25(OH)D (4000IU, ≈12%; 8000IU, ≈38%) without altering intact parathyroid hormone or calcium. The vitamin D metabolite increases in the supplemental vitamin D groups (n=31) were dependent on initial levels as serum 25(OH)D (r=-0.63, p<0.05) and 1,25(OH)D (r=-0.45, p<0.05) at Bsl correlated with their increases after supplementation. Supplemental vitamin D increased interferon (IFN)-γ and interleukin (IL)-10 in subjects that were vitamin D insufficient (serum 25(OH)D<29ng/mL) compared to sufficient (serum 25(OH)D⩾30ng/mL) at Bsl. We conclude that supplemental vitamin D increase a pro- and anti-inflammatory cytokine in those with initially low serum 25(OH)D. Copyright © 2014 Elsevier Ltd. All rights reserved.
Moraes, Claudia Trigo Pedroso; Oliveira, Danielle Bruna Leal; Campos, Angelica Cristine Almeida; Bosso, Patricia Alves; Lima, Hildener Nogueira; Stewien, Klaus Eberhard; Gilio, Alfredo Elias; Vieira, Sandra Elisabete; Botosso, Viviane Fongaro; Durigon, Edison Luiz
2015-01-01
Human respiratory syncytial virus (HRSV) is an important respiratory pathogens among children between zero-five years old. Host immunity and viral genetic variability are important factors that can make vaccine production difficult. In this work, differences between biological clones of HRSV were detected in clinical samples in the absence and presence of serum collected from children in the convalescent phase of the illness and from their biological mothers. Viral clones were selected by plaque assay in the absence and presence of serum and nucleotide sequences of the G2 and F2 genes of HRSV biological clones were compared. One non-synonymous mutation was found in the F gene (Ile5Asn) in one clone of an HRSV-B sample and one non-synonymous mutation was found in the G gene (Ser291Pro) in four clones of the same HRSV-B sample. Only one of these clones was obtained after treatment with the child's serum. In addition, some synonymous mutations were determined in two clones of the HRSV-A samples. In conclusion, it is possible that minor sequences could be selected by host antibodies contributing to the HRSV evolutionary process, hampering the development of an effective vaccine, since we verify the same codon alteration in absence and presence of human sera in individual clones of BR-85 sample. PMID:25742274
Moraes, Claudia Trigo Pedroso; Oliveira, Danielle Bruna Leal; Campos, Angelica Cristine Almeida; Bosso, Patricia Alves; Lima, Hildener Nogueira; Stewien, Klaus Eberhard; Gilio, Alfredo Elias; Vieira, Sandra Elisabete; Botosso, Viviane Fongaro; Durigon, Edison Luiz
2015-02-01
Human respiratory syncytial virus (HRSV) is an important respiratory pathogens among children between zero-five years old. Host immunity and viral genetic variability are important factors that can make vaccine production difficult. In this work, differences between biological clones of HRSV were detected in clinical samples in the absence and presence of serum collected from children in the convalescent phase of the illness and from their biological mothers. Viral clones were selected by plaque assay in the absence and presence of serum and nucleotide sequences of the G2 and F2 genes of HRSV biological clones were compared. One non-synonymous mutation was found in the F gene (Ile5Asn) in one clone of an HRSV-B sample and one non-synonymous mutation was found in the G gene (Ser291Pro) in four clones of the same HRSV-B sample. Only one of these clones was obtained after treatment with the child's serum. In addition, some synonymous mutations were determined in two clones of the HRSV-A samples. In conclusion, it is possible that minor sequences could be selected by host antibodies contributing to the HRSV evolutionary process, hampering the development of an effective vaccine, since we verify the same codon alteration in absence and presence of human sera in individual clones of BR-85 sample.
Perez-Guaita, David; Kuligowski, Julia; Quintás, Guillermo; Garrigues, Salvador; Guardia, Miguel de la
2013-03-30
Locally weighted partial least squares regression (LW-PLSR) has been applied to the determination of four clinical parameters in human serum samples (total protein, triglyceride, glucose and urea contents) by Fourier transform infrared (FTIR) spectroscopy. Classical LW-PLSR models were constructed using different spectral regions. For the selection of parameters by LW-PLSR modeling, a multi-parametric study was carried out employing the minimum root-mean square error of cross validation (RMSCV) as objective function. In order to overcome the effect of strong matrix interferences on the predictive accuracy of LW-PLSR models, this work focuses on sample selection. Accordingly, a novel strategy for the development of local models is proposed. It was based on the use of: (i) principal component analysis (PCA) performed on an analyte specific spectral region for identifying most similar sample spectra and (ii) partial least squares regression (PLSR) constructed using the whole spectrum. Results found by using this strategy were compared to those provided by PLSR using the same spectral intervals as for LW-PLSR. Prediction errors found by both, classical and modified LW-PLSR improved those obtained by PLSR. Hence, both proposed approaches were useful for the determination of analytes present in a complex matrix as in the case of human serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Xiao, Qin; Hu, Bin; Duan, Jiankun; He, Man; Zu, Wanqing
2007-10-01
A novel method for the analysis of four polybrominated diphenyl ethers (PBDEs) in environmental and human serum samples based on hollow fiber-liquid phase microextraction (HF-LPME) followed by gas chromatography-inductively coupled plasma mass spectrometric (GC-ICP-MS) detection has been developed. The organic solvent in the porous hollow fiber was first dipped into the sample for extraction at a given time, and the retracted organic phase was introduced into the GC-ICP-MS for analysis. The addition of methanol has a strong effect on the HF-LPME extraction efficiency. Other significant parameters affecting the extraction efficiency of HF-LPME were also studied. HF-LPME was effective to isolate the analytes from the complex matrix. Under the optimized conditions, the detection limits of the proposed method varied from 15.2 to 40.5 ng/L. In general, the relative standard deviations (RSDs) were less than 10%. Good linearity was obtained with the correlation coefficients all better than 0.999. The proposed method is simple, quick, few microliters of organic solvent required, and is especially suitable for the analysis of the real sample with small amount available. The overall process of HF-LPME with GC-ICP-MS was applied successfully for the determination of polybrominated diphenyl ethers (PBDEs) in environmental and spiked human serum samples, and the results were satisfactory.
Clark, R G; Ellison, R S; Mortleman, L; Kirk, J A; Henderson, H V
1999-08-01
To obtain information on serum and liver vitamin B12 and urinary methylmalonic acid concentrations as diagnostic tests to predict a weight gain response to supplementation with vitamin B12 in young dairy cattle when grazing pasture of low cobalt content. Methodology. Forty dairy cattle (12 Friesian, 14 Friesian x Jersey and 14 Jersey) were allocated to two equal sized groups, treated and untreated, based on liveweight. At monthly intervals for 14 months, all animals were weighed, their serum and urine sampled, their liver biopsied and the pasture sampled from the paddocks they were grazing and going to graze. Serum and liver were assayed for vitamin B12 concentrations. For the first 5 months of the trial, urine was assayed for methylmalonic acid concentrations. Both washed and unwashed pasture samples were assayed for cobalt concentrations. No weight gain response occurred vitamin B12 supplementation in young growing cattle grazing pasture with a cobalt concentration of 0.04-0.06 mg/kg DM. For 5 months of the trial, liver vitamin B12 concentrations from untreated calves were in the range 75-220 nmol/kg and serum vitamin B12 concentrations were as low as 72 pmol/1. There was no associated growth response to supplementation. Further trials involving young cattle grazing pastures with cobalt concentrations less than 0.04 mg/kg DM are required to reliably determine liver and serum vitamin B12 concentrations at which growth responses to vitamin B12 or cobalt supplementation are likely under New Zealand pastoral grazing conditions.
Downs, Jennifer A.; Corstjens, Paul L.A.M.; Mngara, Julius; Lutonja, Peter; Isingo, Raphael; Urassa, Mark; Kornelis, Dieuwke; van Dam, Govert J.
2015-01-01
Circulating Anodic Antigen (CAA) testing is a powerful, increasingly-used tool for diagnosis of active schistosome infection. We sought to determine the feasibility and reliability of measuring CAA in blood spots collected on Whatman 903 Protein Saver cards, which are the predominant filter papers used worldwide for dried blood spot (DBS) research and clinical care. CAA was eluted from blood spots collected from 19 individuals onto Whatman 903 cards in Mwanza, Tanzania, and the assay was optimized to achieve CAA ratios comparable to those obtained from the spots’ corresponding serum samples. The optimized assay was then used to determine the correlation of serum samples (n=16) with DBS from cards that had been stored for 8 years at ambient temperature.Using a DBS volume equivalent to approximately four times the quantity of serum, CAA testing in DBS had a sensitivity of 76% and a specificity of 79% compared to CAA testing in serum. CAA testing was reliable in samples eluted from Whatman 903 cards that had been stored for 8 years at ambient temperature. The overall kappa coefficient was 0.53 (standard error 0.17, p<0.001). We conclude that CAA can be reliably and accurately measured in DBS collected onto the filter paper that is most commonly used for clinical care and research, and that can be stored for prolonged periods of time. This finding opens new avenues for future work among more than 700 million individuals living in areas worldwide in which schistosomes are endemic. PMID:26149541
Dynamics of viral load in Crimean Congo hemorrhagic fever.
Hasanoglu, Imran; Guner, Rahmet; Carhan, Ahmet; K Tufan, Zeliha; Y Caglayik, Dilek; Yilmaz, Gul R; Tasyaran, Mehmet A
2018-04-01
Crimean Congo hemorrhagic fever (CCHF) is a viral zoonotic disease with high mortality rate. There are only a few studies on viral load in CCHF. In our study, we revealed the dynamics of viral load and its relationship with mortality in early phase of the disease. A total of 138 serum samples were collected from 23 patients. All patients had positive PCR for CCHF on admission. Serum samples were obtained daily from all patients for the first 6 days of hospitalization and stored at -80°C for viral load measurement. We found statistically significant difference between mean number of viremic serum samples of fatal and non-fatal patients. Furthermore, non-fatal cases' viral loads demonstrated statistically significant decreases over time; however, we could not observe a similar trend in viral loads of fatal cases. Limited number of studies on CCHF indicate that score of the contest between CCHF virus and immune system determines the survival in CCHF and viral load is found to be the most prognostic factor. In our study, we found that there is a notable decrease trend in viral loads of non-fatal patients over time and this clearance of CCHF virus is significantly related with survival. © 2017 Wiley Periodicals, Inc.
Rauf, Sana; Zhang, Ling; Ali, Asghar; Liu, Yang; Li, Jinghong
2017-02-24
Detection of very low amounts of illicit drugs such as cocaine in clinical fluids like serum continues to be important for many areas in the fight against drug trafficking. Herein, we constructed a label-free nanopore biosensor for rapid and highly sensitive detection of cocaine in human serum and saliva samples based on target-induced strand release strategy. In this bioassay, an aptamer for cocaine was prehybridized with a short complementary DNA. Owing to cocaine specific binding with aptamer, the short DNA strand was displaced from aptamer and translocation of this output DNA through α-hemolysin nanopore generated distinct spike-like current blockages. When plotted in double-logarithmic scale, a linear relationship between target cocaine concentration and output DNA event frequency was obtained in a wide concentration range from 50 nM to 100 μM of cocaine, with the limit of detection down to 50 nM. In addition, this aptamer-based sensor method was successfully applied for cocaine detection in complex biological fluids like human saliva and serum samples with great selectivity. Simple preparation, low cost, rapid, label-free, and real sample detection are the motivating factors for practical application of the proposed biosensor.
Kawaguchi, Migaku; Takatsu, Akiko
2009-08-01
A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.
Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.
González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R
1988-02-01
The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.
Serum chemistry comparisons between captive and free-ranging giraffes (Giraffa camelopardalis).
Schmidt, Debra A; Barbiers, Robyn B; Ellersieck, Mark R; Ball, Ray L; Koutsos, Elizabeth A; Griffin, Mark E; Grobler, Douw; Citino, Scott B; Bush, Mitchell
2011-03-01
Serum chemistry analyses were compared between captive and free-ranging giraffes (Giraffa camelopardalis) in an attempt to better understand some of the medical issues seen with captive giraffes. Illnesses, including peracute mortality, energy malnutrition, pancreatic disease, urolithiasis, hoof disease, and severe intestinal parasitism, may be related to zoo nutrition and management issues. Serum samples were collected from 20 captive giraffes at 10 United States institutions. Thirteen of the captive animal samples were collected from animals trained for blood collection; seven were banked samples obtained from a previous serum collection. These samples were compared with serum samples collected from 24 free-ranging giraffes in South Africa. Differences between captive and free-ranging giraffes, males and females, and adults and subadults were analyzed by using a 2 x 2 x 2 factorial and Fisher's least significant difference for mean separation; when necessary variables were ranked and analyzed via analysis of variance. Potassium and bilirubin concentrations and alanine aminotransferase (ALT) activities were different between captive and free-ranging giraffes, but all fell within normal bovid reference ranges. The average glucose concentration was significantly elevated in free-ranging giraffes (161 mg/dl) compared with captive giraffes (113 mg/dl). All giraffes in this study had glucose concentrations higher than bovine (42-75 mg/ dl) and caprine (48-76 mg/dl) reference ranges. Differences were also seen in lipase, chloride, and magnesium though these findings are likely not clinically significant. There were no differences detected between sexes. Adults had higher concentrations of potassium, total protein, globulins, and chloride and higher gamma glutamyltransferase activities, whereas subadults had higher concentrations of phosphorus. Within the captive group, nonimmobilized animals had higher concentrations of total protein and globulins. Captive giraffe diets need further investigation to determine if the differences seen in this study, especially glucose and bilirubin concentrations and ALT activities, may result in some health problems often seen in captive giraffes.
Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun
2014-02-01
Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from
Min, Li; Cheng, Jian-bo; Shi, Bao-lu; Yang, Hong-jian; Zheng, Nan; Wang, Jia-qi
2015-06-01
Heat stress affects feed intake, milk production, and endocrine status in dairy cows. The temperature-humidity index (THI) is employed as an index to evaluate the degree of heat stress in dairy cows. However, it is difficult to ascertain whether THI is the most appropriate measurement of heat stress in dairy cows. This experiment was conducted to investigate the effects of heat stress on serum insulin, adipokines (leptin and adiponectin), AMP-activated protein kinase (AMPK), and heat shock signal molecules (heat shock transcription factor (HSF) and heat shock proteins (HSP)) in dairy cows and to research biomarkers to be used for better understanding the meaning of THI as a bioclimatic index. To achieve these objectives, two experiments were performed. The first experiment: eighteen lactating Holstein dairy cows were used. The treatments were: heat stress (HS, THI average=81.7, n=9) and cooling (CL, THI average=53.4, n=9). Samples of HS were obtained on August 16, 2013, and samples of CL were collected on April 7, 2014 in natural conditions. The second experiment: HS treatment cows (n=9) from the first experiment were fed for 8 weeks from August 16, 2013 to October 12, 2013. Samples for moderate heat stress, mild heat stress, and no heat stress were obtained, respectively, according to the physical alterations of the THI. Results showed that heat stress significantly increased the serum adiponectin, AMPK, HSF, HSP27, HSP70, and HSP90 (P<0.05). Adiponectin is strongly associated with AMPK. The increases of adiponectin and AMPK may be one of the mechanisms to maintain homeostasis in heat-stressed dairy cows. When heat stress treatment lasted 8 weeks, a higher expression of HSF and HSP70 was observed under moderate heat stress. Serum HSF and HSP70 are sensitive and accurate in heat stress and they could be potential indicators of animal response to heat stress. We recommend serum HSF and HSP70 as meaningful biomarkers to supplement the THI and evaluate moderate heat stress in dairy cows in the future.
Min, Li; Cheng, Jian-bo; Shi, Bao-lu; Yang, Hong-jian; Zheng, Nan; Wang, Jia-qi
2015-01-01
Heat stress affects feed intake, milk production, and endocrine status in dairy cows. The temperature-humidity index (THI) is employed as an index to evaluate the degree of heat stress in dairy cows. However, it is difficult to ascertain whether THI is the most appropriate measurement of heat stress in dairy cows. This experiment was conducted to investigate the effects of heat stress on serum insulin, adipokines (leptin and adiponectin), AMP-activated protein kinase (AMPK), and heat shock signal molecules (heat shock transcription factor (HSF) and heat shock proteins (HSP)) in dairy cows and to research biomarkers to be used for better understanding the meaning of THI as a bioclimatic index. To achieve these objectives, two experiments were performed. The first experiment: eighteen lactating Holstein dairy cows were used. The treatments were: heat stress (HS, THI average=81.7, n=9) and cooling (CL, THI average=53.4, n=9). Samples of HS were obtained on August 16, 2013, and samples of CL were collected on April 7, 2014 in natural conditions. The second experiment: HS treatment cows (n=9) from the first experiment were fed for 8 weeks from August 16, 2013 to October 12, 2013. Samples for moderate heat stress, mild heat stress, and no heat stress were obtained, respectively, according to the physical alterations of the THI. Results showed that heat stress significantly increased the serum adiponectin, AMPK, HSF, HSP27, HSP70, and HSP90 (P<0.05). Adiponectin is strongly associated with AMPK. The increases of adiponectin and AMPK may be one of the mechanisms to maintain homeostasis in heat-stressed dairy cows. When heat stress treatment lasted 8 weeks, a higher expression of HSF and HSP70 was observed under moderate heat stress. Serum HSF and HSP70 are sensitive and accurate in heat stress and they could be potential indicators of animal response to heat stress. We recommend serum HSF and HSP70 as meaningful biomarkers to supplement the THI and evaluate moderate heat stress in dairy cows in the future. PMID:26055916
Tiss, Ali; Timms, John F; Smith, Celia; Devetyarov, Dmitry; Gentry-Maharaj, Aleksandra; Camuzeaux, Stephane; Burford, Brian; Nouretdinov, Ilia; Ford, Jeremy; Luo, Zhiyuan; Jacobs, Ian; Menon, Usha; Gammerman, Alex; Cramer, Rainer
2010-12-01
Our objective was to test the performance of CA125 in classifying serum samples from a cohort of malignant and benign ovarian cancers and age-matched healthy controls and to assess whether combining information from matrix-assisted laser desorption/ionization (MALDI) time-of-flight profiling could improve diagnostic performance. Serum samples from women with ovarian neoplasms and healthy volunteers were subjected to CA125 assay and MALDI time-of-flight mass spectrometry (MS) profiling. Models were built from training data sets using discriminatory MALDI MS peaks in combination with CA125 values and tested their ability to classify blinded test samples. These were compared with models using CA125 threshold levels from 193 patients with ovarian cancer, 290 with benign neoplasm, and 2236 postmenopausal healthy controls. Using a CA125 cutoff of 30 U/mL, an overall sensitivity of 94.8% (96.6% specificity) was obtained when comparing malignancies versus healthy postmenopausal controls, whereas a cutoff of 65 U/mL provided a sensitivity of 83.9% (99.6% specificity). High classification accuracies were obtained for early-stage cancers (93.5% sensitivity). Reasons for high accuracies include recruitment bias, restriction to postmenopausal women, and inclusion of only primary invasive epithelial ovarian cancer cases. The combination of MS profiling information with CA125 did not significantly improve the specificity/accuracy compared with classifications on the basis of CA125 alone. We report unexpectedly good performance of serum CA125 using threshold classification in discriminating healthy controls and women with benign masses from those with invasive ovarian cancer. This highlights the dependence of diagnostic tests on the characteristics of the study population and the crucial need for authors to provide sufficient relevant details to allow comparison. Our study also shows that MS profiling information adds little to diagnostic accuracy. This finding is in contrast with other reports and shows the limitations of serum MS profiling for biomarker discovery and as a diagnostic tool.
Roberts, Michael S; Turner, David C; Owens, Thandranese S; Ramachandran, Abhijit; Wetmore, Cynthia; Throm, Stacy L; Stewart, Clinton F
2013-06-15
A LC-ESI-MS/MS method for the determination of crenolanib (CP-868,596) in human serum was developed and validated employing d4-CP-868,596 as an internal standard (ISTD). In addition to human serum, the method was also partially validated for crenolanib determination in human cerebrospinal fluid (CSF) samples. Sample aliquots (50μl of serum or CSF) were prepared for analysis using liquid-liquid extraction (LLE) with tert-butyl methyl ether. Chromatography was performed using a phenomenex Gemini C18 column (3μm, 100mm×4.6mm I.D.) in a column heater set at 50°C and an isocratic mobile phase (methanol/water/formic acid at a volume ratio of 25/25/0.15, v/v/v). The flow rate was 0.45mL/min, and the retention time for both analyte and ISTD was less than 3.5min. Samples were analyzed with an API-5500 LC-MS/MS system (ESI) in positive ionization mode coupled to a Shimadzu HPLC system. The ion transitions monitored were m/z 444.4→373.1 and m/z 448.2→374.2 for crenolanib and ISTD, respectively. The method was linear over the range of 5-1000ng/mL for serum and 0.5-1000ng/mL for CSF. For human serum, both intra-day and inter-day precision were <4%, while intra-day and inter-day accuracy were within 8% of nominal values. Recovery was greater than 50% for both the analyte and ISTD. For CSF samples, both intra-day and inter-day precision were <9% except at the lower limit of quantification (LLOQ) which was <17%. The intra-day and inter-day accuracy were within 11% of the nominal CSF concentrations. After validation, this method was successfully applied to the analysis of serial pharmacokinetic samples obtained from a child treated with oral crenolanib. Copyright © 2013 Elsevier B.V. All rights reserved.
Low-cost and reagent-free paper-based device to detect chloride ions in serum and sweat.
Cinti, Stefano; Fiore, Luca; Massoud, Renato; Cortese, Claudio; Moscone, Danila; Palleschi, Giuseppe; Arduini, Fabiana
2018-03-01
The recent goal of sustainability in analytical chemistry has boosted the development of eco-designed analytical tools to deliver fast and cost-effective analysis with low economic and environmental impact. Due to the recent focus in sustainability, we report the use of low-cost filter paper as a sustainable material to print silver electrodes and to load reagents for a reagent-free electrochemical detection of chloride in biological samples, namely serum and sweat. The electrochemical detection of chloride ions was carried out by exploiting the reaction of the analyte (i.e. chloride) with the silver working electrode. During the oxidation wave in cyclic voltammetry the silver ions are produced, thus they react with chloride ions to form AgCl, while in the reduction wave, the following reaction occurs: AgCl + e - -->Ag + Cl - . These reactions at the electrode surface resulted in anodic/cathodic peaks directly proportional to the chloride ions in solution. Chloride ions were detected with the addition of only 10μL of the sample on the paper-based electrochemical cell, obtaining linearity up to 200mM with a detection limit equal to 1mM and relative standard deviation lower than 10%. The accuracy of the sensor was evaluated in serum and sweat samples, with percentage recoveries between 93 ± 10 and 108 ± 8%. Moreover, the results achieved with the paper-based device were positively compared with those obtained by using the gold standard method (Ion Selective Electrode) adopted in routine clinical analyses. Copyright © 2017 Elsevier B.V. All rights reserved.
Sommardahl, Carla S; Frank, Nicholas; Elliott, Sarah B; Webb, Latisha L; Refsal, Kent R; Denhart, Joseph W; Thompson, Donald L
2005-06-01
To determine the effects of levothyroxine sodium (L-T4) on serum concentrations of thyroid gland hormones and responses to injections of thyrotropin-releasing hormone (TRH) in euthyroid horses. 12 healthy adult mares. 8 horses received an incrementally increasing dosage of L-T4 (24, 48, 72, or 96 mg of L-T4/d) for weeks 1 to 8. Each dose was provided for 2 weeks. Four additional horses remained untreated. Serum concentrations of total triiodothyronine (tT3), total thyroxine (tT4), free T3 (fT3), free T4 (fT4), and thyroid-stimulating hormone (TSH) were measured in samples obtained at weeks 0, 2, 4, 6, and 8; 1.2 mg of TRH was then administered i.v., and serum concentrations of thyroid gland hormones were measured 2 and 4 hours after injection. Serum reverseT3 (rT3) concentration was also measured in the samples collected at weeks 0 and 8. Treated horses lost a significant amount of weight (median, 19 kg). Significant treatment-by-time effects were detected for serum tT3, tT4, fT3, fT4, and TSH concentrations, and serum tT4 concentrations were positively correlated (r, 0.95) with time (and therefore dosage) in treated horses. Mean +/- SD serum rT3 concentration significantly increased in treated horses (3.06 +/- 0.51 nmol/L for week 8 vs 0.74 +/- 0.22 nmol/L for week 0). Serum tT3, tT4, fT3, and TSH concentrations in response to TRH injections differed significantly between treated and untreated horses. Administration of levothyroxine sodium increased serum tT4 concentrations and blunted responses toTRH injection in healthy euthyroid horses.
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Satoh, Mamoru; Ishige, Takayuki; Ogawa, Shoujiro; Nishimura, Motoi; Matsushita, Kazuyuki; Higashi, Tatsuya; Nomura, Fumio
2016-11-01
The quantification of serum 25-hydroxyvitamin D [25(OH)D] as an indicator of vitamin D status is currently primarily conducted by immunoassays, yet LC-MS/MS would allow more accurate determination. Furthermore, LC-MS/MS would allow simultaneous measurement of multiple analytes. The aim of this study was to develop and validate an LC-MS/MS method to simultaneously measure four vitamin D metabolites (25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 ) in serum for clinical laboratory applications. Serum samples were first prepared in a 96-well supported liquid extraction plate and the eluate was derivatized using the Cookson-type reagent 4-(4'-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD), which rapidly and quantitatively reacts with the s-cis-diene structure of vitamin D metabolites. The derivatized samples were subjected to LC-MS/MS, ionized by electrospray ionization (positive-ion mode), and detected by selected reaction monitoring. The lower limits of quantification for 25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 were 0.091, 0.020, 0.013, and 0.024 ng/mL, respectively. The accuracy values and the extraction recoveries for these four metabolites were satisfactory. Serum 25(OH)D levels determined by our LC-MS/MS were compared with those obtained by conventional radioimmunoassay (RIA) that cannot distinguish 25(OH)D 3 and 25(OH)D 2 . The values obtained by the RIA method exhibited a mean bias of about 8.35 ng/mL, most likely as a result of cross reaction of the antibody with low-abundance metabolites, including 24,25(OH) 2 D 3 . Various preanalytical factors, such as long sample sitting prior to serum separation, repeated freeze-thaw cycles, and the presence of anticoagulants, had no significant effects on these determinations. This high-throughput LC-MS/MS simultaneous assay of the four vitamin D metabolites 25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 required as little as 20 μL serum. This method will aid further understanding of low-abundance vitamin D metabolites, as well as the accurate determination of 25(OH)D 3 and 25(OH)D 2 .
Serum free light chain reference values: a critical approach.
Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario
2013-05-01
The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.
Alizadeh, Naader; Mohammadi, Abdorreza; Tabrizchi, Mahmoud
2008-03-07
A simple, rapid and highly sensitive method for simultaneous analysis of methamphetamine (MA) and 3,4-methylenedioxy methamphetamine (MDMA) in human serum was developed using the solid-phase microextraction (SPME) combined with ion mobility spectrometry (IMS). A dodecylsulfate-doped polypyrrole (PPy-DS) was applied as a new fiber for SPME. Electrochemically polymerized PPy is formed on the surface of a platinum wire and will contain charge-compensating anion (dodecylsulfate) incorporated during synthesis using cyclic voltammetry (CV) technique. The extraction properties of the fiber to MA and MDMA were examined, using a headspace-SPME (HS-SPME) device and thermal desorption in injection port of IMS. The results show that PPy-DS as a SPME fiber coating is suitable for the successful extraction of these compounds. This method is suitable for the identification and determination of MAs, is not time-consuming, requires small quantities of sample and does not require any derivatization. Parameters like pH, extraction time, ionic strength, and temperature of the sample were studied and optimized to obtain the best extraction results. The HS-SPME-IMS method provided good repeatability (RSDs<7.8 %) for spiked serum samples. The calibration graphs were linear in the range of 20-4000 ng ml(-1) (R(2)>0.99) and detection limits for MDMA and MA were 5 and 8 ng ml(-1), respectively. HS-SPME-IMS of non-spiked serum sample provided a spectrum without any peak from the matrix, supporting an effective sample clean-up. Finally, the proposed method was applied for analysis one of the ecstasy tablet.
McBride, David; Lovelock, Kirsten; Shepherd, Daniel; Dirks, Kim; Welch, David; Gray, Andrew
2016-10-01
The New Zealand Ministry of Health responded to community concern about dioxin exposure during on-site remediation of a pesticide-contaminated rural area by commissioning this exposed-referent study of serum dioxins and health in local residents. All 200 residents were eligible, with age and sex matching to demographically comparable referents. Face-to-face interviews included questions on health status, health-related quality of life (HRQOL) and perceptions about community consultation. Thirty serum samples were obtained, eligibility being based on likelihood of exposure and age. Both HRQOL and serum outcomes were analysed by the appropriate regression methods. Of 200 eligible residents, 139 (69.5%) participated, with 139 matched referents. Mapua residents had lower physical and psychological HRQOL scores, but no difference in health status. 2,3,7,8 TCDD was below the limit of detection in the majority of all serum samples, with some congeners being higher in referents. Perceptions of the communication process were equivocal. Both dioxin levels and measures of health did not differ significantly between the exposed community and controls. Implications for public health: The results suggest neither significant dioxin exposure nor community health effects. Oversight by expert panel with health expertise, allied to sound communication, may have helped the community understand the risks. © 2016 Public Health Association of Australia.
Schoeman, J P; Herrtage, M E
2007-12-01
This prospective, cross-sectional, interventional study was designed to determine the association between the hormones of the pituitary-adrenal and pituitary-thyroid axes and other clinical parameters with the blood glucose perturbations in dogs with naturally occurring Babesia canis rossi babesiosis. Thirty-six dogs with canine babesiosis were studied. Blood samples were obtained from the jugular vein in each dog prior to treatment at admission to hospital and serum endogenous adrenocorticotrophic hormone (ACTH), pre-ACTH cortisol, thyroxine, free thyroxine and TSH concentrations were measured. Immediately thereafter each dog was injected intravenously with 5 microg/kg of ACTH (tetracosactrin). A 2nd blood sample was taken 1 hour later for serum post-ACTH cortisol measurement. Three patient groups were recruited: hypoglycaemic dogs (glucose < 3.3 mmol/l, n = 12); normoglycaemic dogs (glucose 3.3-5.5 mmol/l, n = 12); hyperglycaemic dogs (glucose > 5.5 mmol/l, n = 12). Basal and post-ACTH serum cortisol concentrations were significantly higher in hypoglycaemic dogs, whereas body temperature, serum thyroxine and free thyroxine were significantly lower in hypoglycaemic dogs. Haematocrit was significantly lower in both hypo-and hyperglycaemic dogs compared with normoglycaemic dogs. Low blood glucose concentrations were significantly associated with high basal and post-ACTH cortisol concentrations and with low serum thyroxine and free thyroxine concentrations in dogs suffering from B. canis rossi babesiosis.
Comparison of RFFIT tests with different standard sera and testing procedures.
Yu, Peng-cheng; Noguchi, Akira; Inoue, Satoshi; Tang, Qing; Rayner, Simon; Liang, Guo-dong
2012-06-01
The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.
Primary cultures of astrocytes from fetal bovine brain.
Ballarin, Cristina; Peruffo, Antonella
2012-01-01
We describe here a method to obtain primary cell cultures from the cerebral cortex and the hypothalamus of bovine fetuses. We report how tissue origin, developmental stages, and culture medium conditions influence cell differentiation and the prevalence of glial cells vs. neurons. We compare explants from early, middle, and late stages of development and two different fetal calf serum concentrations (1 and 10%) to identify the best conditions to obtain and grow viable astrocytes in culture. In addition, we describe how to cryopreserve and obtain viable cortical astrocytes from frozen fetal bovine brain samples.
Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E
1991-01-01
An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166
Ogata, Norio
2006-04-01
The worldwide consensus of the minimum protective anti-HBs level against HBV infection is 10 mIU/mL on assays standardized by the World Health Organization (WHO) reference preparations. To investigate whether this value could be applied to recipients of yeast-derived recombinant HB vaccine containing the major surface protein of subtype adr (Bimmugen, Astellas Pharmaceutical, Tokyo), we compared anti-HBs measurements between chemiluminescent immunoassay (CLIA) (Architect Ausab, Abbott Japan, Tokyo) and chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse Forte, Fujirebio, Tokyo) in given serum samples obtained from the vaccinees. The vaccine and the two assay methods are currently in a wide use in Japan. The study included 300 medical students who completed a standard vaccination course (0, 1 and 6 months). Serum samples obtained 1 month or 13 months after completing the vaccination were simultaneously tested for anti-HBs by CLIA and CLEIA. In 147 samples with quantifiable values on both CLIA and CLEIA (10 to 1000 mIU/mL) the geometric mean titer on CLEIA (225.0 mIU/mL) was significantly higher than that on CLIA (94.5 mIU/mL) (p < 0.0001). Of 26 subjects with CLIA measurements below 10 mIU/mL, 15 samples (57.7%) showed CLEIA measurements more than 10 mIU/mL. Thus, in the subtype adr-vaccinees CLEIA demonstrated considerably high serum anti-HBs measurements compared to CLIA and discordance in determining critical anti-HBs level of 10 mIU/mL was observed in more than half the samples. This suggests that the minimum HBV-protective anti HBs titer of 10 mIU/mL is difficult to be introduced to Japan where subtype adr-HB vaccines or -HBV infection are prevalent, unless characteristics of assay methods are carefully evaluated.
A screening method for biotinidase deficiency in newborns.
Heard, G S; Secor McVoy, J R; Wolf, B
1984-01-01
We describe a method for neonatal screening for biotinidase (EC 3.5.1.12) deficiency. Biotinidase activity is assessed colorimetrically from dried samples of whole blood spotted on the same filter papers as used in the neonatal screening for phenylketonuria. After the reaction, samples from normal infants are characteristically purple, whereas those from affected individuals are straw-colored. To confirm the deficiency, the enzyme is quantitatively assayed in additional blood spots or serum. A pilot study has been initiated with samples obtained by the Commonwealth of Virginia for phenylketonuria testing.
Ambient and at-the-ear occupational noise exposure and serum lipid levels.
Arlien-Søborg, Mai C; Schmedes, Astrid S; Stokholm, Z A; Grynderup, M B; Bonde, J P; Jensen, C S; Hansen, Å M; Frederiksen, T W; Kristiansen, J; Christensen, K L; Vestergaard, J M; Lund, S P; Kolstad, H A
2016-10-01
Occupational and residential noise exposure has been related to increased risk of cardiovascular disease. Alteration of serum lipid levels has been proposed as a possible causal pathway. The objective of this study was to investigate the relation between ambient and at-the-ear occupational noise exposure and serum levels of total cholesterol, low-density lipoprotein-cholesterol, high-density lipoprotein-cholesterol, and triglycerides when accounting for well-established predictors of lipid levels. This cross-sectional study included 424 industrial workers and 84 financial workers to obtain contrast in noise exposure levels. They provided a serum sample and wore portable dosimeters that every 5-s recorded ambient noise exposure levels during a 24-h period. We extracted measurements obtained during work and calculated the full-shift mean ambient noise level. For 331 workers who kept a diary on the use of a hearing protection device (HPD), we subtracted 10 dB from every noise recording obtained during HPD use and estimated the mean full-shift noise exposure level at the ear. Mean ambient noise level was 79.9 dB (A) [range 55.0-98.9] and the mean estimated level at the ear 77.8 dB (A) [range 55.0-94.2]. Ambient and at-the-ear noise levels were strongly associated with increasing levels of triglycerides, cholesterol-HDL ratio, and decreasing levels of HDL-cholesterol, but only in unadjusted analyses that did not account for HPD use and other risk factors. No associations between ambient or at-the-ear occupational noise exposure and serum lipid levels were observed. This indicates that a causal pathway between occupational and residential noise exposure and cardiovascular disease does not include alteration of lipid levels.
Walscheid, Karoline; Heiligenhaus, Arnd; Holzinger, Dirk; Roth, Johannes; Heinz, Carsten; Tappeiner, Christoph; Kasper, Maren; Foell, Dirk
2015-12-01
Juvenile idiopathic arthritis-associated uveitis (JIAU) is the most common uveitis entity in childhood. As S100A8/A9 and S100A12 proteins are valuable biomarkers in childhood arthritis, we investigated the occurrence of these proteins in childhood uveitis. Serum samples from patients with JIAU (n = 79) or idiopathic anterior uveitis (IAU, n = 24), as well as from nonuveitic controls (n = 24), were collected. Furthermore, aqueous humor samples (JIAU n = 17, nonuveitic controls n = 16, IAU n = 12) were obtained. Samples were analyzed for S100A8/A9 and S100A12 protein levels by ELISA. Intergroup comparisons were performed, involving patient data, clinical data, and S100 levels. S100A8/A9 and S100A12 serum levels were elevated in IAU and JIAU patients as compared to nonuveitic controls (all P < 0.05). S100 serum levels in JIAU patients were higher in active arthritis (not significant; P = 0.289 for S100A8/A9 and P = 0.196 for S100A12) and active uveitis (P = 0.010 for S100A8/A9 and P = 0.026 for S100A12) than in controls. No significant differences in S100 levels were found in a subgroup analysis for sex, antinuclear antibody (ANA) status, disease duration, or presence of uveitis complications. In JIAU patients, S100 serum levels correlated with age and age at onset of uveitis. A longitudinal analysis in JIAU patients showed a correlation of serum S100A8/A9 and S100A12 levels with uveitis activity (both P = 0.03). S100A8/A9 levels in aqueous humor of patients with JIAU (P = 0.001) and IAU (P = 0.0002) were increased as compared to nonuveitic controls. Increased S100A8/A9 and S100A12 levels are found in the serum and aqueous humor of patients with autoimmune uveitis. Serum levels reflect activity of joint and eye disease.
Fiber-optic evanescent-wave spectroscopy for fast multicomponent analysis of human blood
NASA Astrophysics Data System (ADS)
Simhi, Ronit; Gotshal, Yaron; Bunimovich, David; Katzir, Abraham; Sela, Ben-Ami
1996-07-01
A spectral analysis of human blood serum was undertaken by fiber-optic evanescent-wave spectroscopy (FEWS) by the use of a Fourier-transform infrared spectrometer. A special cell for the FEWS measurements was designed and built that incorporates an IR-transmitting silver halide fiber and a means for introducing the blood-serum sample. Further improvements in analysis were obtained by the adoption of multivariate calibration techniques that are already used in clinical chemistry. The partial least-squares algorithm was used to calculate the concentrations of cholesterol, total protein, urea, and uric acid in human blood serum. The estimated prediction errors obtained (in percent from the average value) were 6% for total protein, 15% for cholesterol, 30% for urea, and 30% for uric acid. These results were compared with another independent prediction method that used a neural-network model. This model yielded estimated prediction errors of 8.8% for total protein, 25% for cholesterol, and 21% for uric acid. spectroscopy, fiber-optic evanescent-wave spectroscopy, Fourier-transform infrared spectrometer, blood, multivariate calibration, neural networks.
Hadar, T; Margalith, M; Sagiv, E; Sarov, B; Sarov, I
1995-05-01
The feasibility of using serum IgM, IgA and IgG antibodies specific to Epstein-Barr virus (EBV) viral capsid antigen (VCA), as determined by immunoperoxidase assay (IPA), for the early diagnosis of mononucleosis was evaluated in 65 patients with infectious mononucleosis (IMN). Control groups consisted of 104 healthy students and 15 cytomegalovirus-infected patients. In the first serum sample obtained upon admission, IgM antibodies (titer > or = 64) to EBV VCA were found in 64 of the 65 IMN patients (98%), while EBV-VCA IgA antibodies (titer > or = 32) were found in 32 patients (49%). In those particular titers, no EBV-VCA IgM or IgA antibodies were found in any of the control sera. EBV-VCA-specific IgM antibodies were also not detected in any of the 15 patients with cytomegalovirus infection. In sera obtained from IMN patients within 10 days of the onset of symptoms, 18 of 19 (95%) were IgM seropositive. This study demonstrates that serum EBV-VCA IgM antibodies (titer > or = 64) as determined by IPA are highly specific (100%) and highly sensitive (98%) and can be of value for the early and rapid diagnosis of EBV-IMN infection.
O'Bryant, Sid E; Xiao, Guanghua; Barber, Robert; Huebinger, Ryan; Wilhelmsen, Kirk; Edwards, Melissa; Graff-Radford, Neill; Doody, Rachelle; Diaz-Arrastia, Ramon
2011-01-01
There is no rapid and cost effective tool that can be implemented as a front-line screening tool for Alzheimer's disease (AD) at the population level. To generate and cross-validate a blood-based screener for AD that yields acceptable accuracy across both serum and plasma. Analysis of serum biomarker proteins were conducted on 197 Alzheimer's disease (AD) participants and 199 control participants from the Texas Alzheimer's Research Consortium (TARC) with further analysis conducted on plasma proteins from 112 AD and 52 control participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI). The full algorithm was derived from a biomarker risk score, clinical lab (glucose, triglycerides, total cholesterol, homocysteine), and demographic (age, gender, education, APOE*E4 status) data. Alzheimer's disease. 11 proteins met our criteria and were utilized for the biomarker risk score. The random forest (RF) biomarker risk score from the TARC serum samples (training set) yielded adequate accuracy in the ADNI plasma sample (training set) (AUC = 0.70, sensitivity (SN) = 0.54 and specificity (SP) = 0.78), which was below that obtained from ADNI cerebral spinal fluid (CSF) analyses (t-tau/Aβ ratio AUC = 0.92). However, the full algorithm yielded excellent accuracy (AUC = 0.88, SN = 0.75, and SP = 0.91). The likelihood ratio of having AD based on a positive test finding (LR+) = 7.03 (SE = 1.17; 95% CI = 4.49-14.47), the likelihood ratio of not having AD based on the algorithm (LR-) = 3.55 (SE = 1.15; 2.22-5.71), and the odds ratio of AD were calculated in the ADNI cohort (OR) = 28.70 (1.55; 95% CI = 11.86-69.47). It is possible to create a blood-based screening algorithm that works across both serum and plasma that provides a comparable screening accuracy to that obtained from CSF analyses.
Piroozmand, Ahmad; Soltani, Babak; Razavizadeh, Mohsen; Matini, Amir Hasan; Gilasi, Hamid Reza; Zavareh, Abbas Nassaji; Soltani, Siamak
2017-12-01
Helicobacter pylori ( H. pylori ) is an important and common contagious human pathogen which may cause peptic ulcer and also gastric cancer. The definite diagnosis of it is made through invasive tests. Recently, non-invasive tests including serologic tests of serum and saliva have been conducted for diagnosis of H. pylori infection. In this research, the diagnostic values of serum and salivary serology were compared together to use salivary anti- H. pylori test as an alternative method in the future. During this prospective case-control study on patients who were candidates for endoscopy and gastric biopsy from March 2015 to April 2016 in Shahid Beheshti hospital, Kashan, Iran, serum and salivary samples were obtained for measurement of Immunoglobulin G (IgG) antibody levels against H. pylori by enzyme-linked immunosorbent assay (ELISA). Histopathology was the gold standard test. Statistical analysis was performed by SPSS software version 16. Statistical tests included Kolmogorov-Smirnov, independent-samples t-test, Chi-square, Mann-Whitney U, Kruskal-Wallis, McNemar and correlation. Of 123 patients, sixty-one patients (49.6%) were H. pylori -positive according to histology. The median levels of anti- H. pylori antibodies in serum (p<0.001) and saliva (p<0.001) of H. pylori -positive cases were significantly higher than H. pylori -negative cases. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and accuracy of serologic tests in serum were 75%, 79%, 3.5, 0.3, 77% and for saliva were 85%, 82%, 4.7, 0.18, 84% respectively. Diagnostic values of salivary ELISA are comparable to serum ELISA and can be used as an alternative modality for diagnosis of H. pylori infection.
Almario, R U; Karakas, S E
2015-02-01
Wingless-type MMTV integration site family member (WNT) signaling and WNT-inhibitors have been implicated in regulation of adipogenesis, insulin resistance, pancreatic function, and inflammation. Our goal was to determine serum proteins involved in WNT signaling (WNT5 and WISP2) and WNT inhibition (SFRP4 and SFRP5) as they relate to obesity, serum adipokines, insulin resistance, insulin secretion, and inflammation in humans. Study population comprised 57 insulin resistant women with polycystic ovary syndrome (PCOS) and 27 reference women. In a cross-sectional study, blood samples were obtained at fasting, during oral, and frequently sampled intravenous glucose tolerance tests. Serum WNT5, WISP2, and SFRP4 concentrations did not differ between PCOS vs. reference women. Serum WNT5 correlated inversely with weight both in PCOS and reference women, and correlated directly with insulin response during oral glucose tolerance test in PCOS women. Serum WISP2 correlated directly with fatty acid binding protein 4. Serum SFRP5 did not differ between obese (n=32) vs. nonobese (n=25) PCOS women, but reference women had lower SFRP5 (p<5×10(-6) as compared to both PCOS groups). Serum SFRP5 correlated inversely with IL-1β, TNF-α, cholesterol, and apoprotein B. These findings demonstrated that WNT5 correlated inversely with adiposity and directly with insulin response, and the WNT-inhibitor SFRP5 may be anti-inflammatory. Better understanding of the role of WNT signaling in obesity, insulin resistance, insulin secretion, lipoprotein metabolism, and inflammation is important for prevention and treatment of metabolic syndrome, diabetes and cardiovascular disease. © Georg Thieme Verlag KG Stuttgart · New York.
Huh, Jung Wook; Kim, Sung Chun; Sohn, Insuk; Jung, Sin-Ho; Kim, Hee Cheol
2016-01-01
Background In this study, we established and validated a model for predicting prognosis of stage IIA colon cancer patients based on expression profiles of aptamers in serum. Methods Bloods samples were collected from 227 consecutive patients with pathologic T3N0M0 (stage IIA) colon cancer. We incubated 1,149 serum molecule-binding aptamer pools of clinical significance with serum from patients to obtain aptamers bound to serum molecules, which were then amplified and marked. Oligonucleotide arrays were constructed with the base sequences of the 1,149 aptamers, and the marked products identified above were reacted with one another to produce profiles of the aptamers bound to serum molecules. These profiles were organized into low- and high-risk groups of colon cancer patients based on clinical information for the serum samples. Cox proportional hazards model and leave-one-out cross-validation (LOOCV) were used to evaluate predictive performance. Results During a median follow-up period of 5 years, 29 of the 227 patients (11.9%) experienced recurrence. There were 212 patients (93.4%) in the low-risk group and 15 patients (6.6%) in the high-risk group in our aptamer prognosis model. Postoperative recurrence significantly correlated with age and aptamer risk stratification (p = 0.046 and p = 0.001, respectively). In multivariate analysis, aptamer risk stratification (p < 0.001) was an independent predictor of recurrence. Disease-free survival curves calculated according to aptamer risk level predicted through a LOOCV procedure and age showed significant differences (p < 0.001 from permutations). Conclusion Aptamer risk stratification can be a valuable prognostic factor in stage II colon cancer patients. PMID:26908450
Abdelwahab, Mohamed; Loa, Chien Chang; Wu, Ching Ching; Lin, Tsang Long
2015-06-01
Nucleocapsid (N) protein gene of turkey coronavirus (TCoV) was expressed in a prokaryotic system and used to develop an enzyme-linked immunosorbent assay (ELISA) for detection of antibody to TCoV. Anti-TCoV hyperimmune turkey serum and normal turkey serum were used as positive or negative controls for optimization of the ELISA. Goat anti-turkey IgG (H+L) conjugated with horseradish peroxidase was used as detector antibody. Three hundred and twenty two turkey sera from the field were used to evaluate the performance of ELISA and determine the cut-off point of ELISA. The established ELISA was also examined with serum samples obtained from turkeys experimentally infected with TCoV. Those serum samples were collected at various time intervals from 1 to 63 days post-infection. The optimum conditions for differentiation between anti-TCoV hyperimmune serum and normal turkey serum were recombinant TCoV N protein concentration at 20 μg/ml, serum dilution at 1:800, and conjugate dilution at 1:10,000. Of the 322 sera from the field, 101 were positive for TCoV by immunofluorescent antibody assay (IFA). The sensitivity and specificity of the ELISA relative to IFA test were 86.0% and 96.8%, respectively, using the optimum cut-off point of 0.2 as determined by logistic regression method. Reactivity of anti-rotavirus, anti-reovirus, anti-adenovirus, or anti-enterovirus antibodies with the recombinant N protein coated on the ELISA plates was not detected. These results indicated that the established antibody-capture ELISA in conjunction with recombinant TCoV N protein as the coating protein can be utilized for detection of antibodies to TCoV in turkey flocks. Copyright © 2015 Elsevier B.V. All rights reserved.
Fosse, J; Laroche, M; Rossero, A; Fédérighi, M; Seegers, H; Magras, C
2006-09-01
Campylobacter is one of the main causes of human foodborne bacterial disease associated with meat consumption in developed countries. Therefore, the most effective approach for recovery and detection of Campylobacter from meat should be determined. Two hundred ninety pork skin and chine samples were inoculated with Campylobacter jejuni NCTC 11168 and two strains of Campylobacter coli. Campylobacter cells were then recovered from suspensions and enumerated by direct plating. Campylobacter recovery was evaluated by comparing results for two methods of sample collection (swabbing and mechanical pummeling) and three recovery fluids (peptone water, 5% glucose serum, and demineralized water). End-point multiplex PCR was performed to evaluate the compatibility of the recovery fluids with direct PCR detection techniques. Mean recovery ratios differed significantly between pork skin and chine samples. Ratios were higher for mechanical pummeling (0.53 for pork skin and 0.49 for chine) than for swabbing (0.31 and 0.13, respectively). For pork skin, ratios obtained with peptone water (0.50) and with glucose serum (0.55) were higher than those obtained with demineralized water (0.16). Significant differences were not observed for chine samples. Direct multiplex PCR detection of Campylobacter was possible with pork skin samples. The tools for Campylobacter recovery must be appropriate for the meat matrix to be evaluated. In this study, less than 66% of inoculated Campylobacter was recovered from meat. This underestimation must be taken into account for quantitative risk analysis of Campylobacter infection.
White, P Lewis; Barnes, Rosemary A; Springer, Jan; Klingspor, Lena; Cuenca-Estrella, Manuel; Morton, C Oliver; Lagrou, Katrien; Bretagne, Stéphane; Melchers, Willem J G; Mengoli, Carlo; Donnelly, J Peter; Heinz, Werner J; Loeffler, Juergen
2015-09-01
Aspergillus PCR testing of serum provides technical simplicity but with potentially reduced sensitivity compared to whole-blood testing. With diseases for which screening to exclude disease represents an optimal strategy, sensitivity is paramount. The associated analytical study confirmed that DNA concentrations were greater in plasma than those in serum. The aim of the current investigation was to confirm analytical findings by comparing the performance of Aspergillus PCR testing of plasma and serum in the clinical setting. Standardized Aspergillus PCR was performed on plasma and serum samples concurrently obtained from hematology patients in a multicenter retrospective anonymous case-control study, with cases diagnosed according to European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and the National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (19 proven/probable cases and 42 controls). Clinical performance and clinical utility (time to positivity) were calculated for both kinds of samples. The sensitivity and specificity for Aspergillus PCR when testing serum were 68.4% and 76.2%, respectively, and for plasma, they were 94.7% and 83.3%, respectively. Eighty-five percent of serum and plasma PCR results were concordant. On average, plasma PCR was positive 16.8 days before diagnosis and was the earliest indicator of infection in 13 cases, combined with other biomarkers in five cases. On average, serum PCR was positive 10.8 days before diagnosis and was the earliest indicator of infection in six cases, combined with other biomarkers in three cases. These results confirm the analytical finding that the sensitivity of Aspergillus PCR using plasma is superior to that using serum. PCR positivity occurs earlier when testing plasma and provides sufficient sensitivity for the screening of invasive aspergillosis while maintaining methodological simplicity. Copyright © 2015 White et al.
Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein
2015-03-01
Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.
Stojsavljević, Aleksandar; Trifković, Jelena; Rasić-Milutinović, Zorica; Jovanović, Dragana; Bogdanović, Gradimir; Mutić, Jelena; Manojlović, Dragan
2018-07-01
Inductively coupled plasma-mass spectrometry ((ICP-MS)) was used to determine three toxic (Ni, As, Cd) and six essential trace elements (Cr, Mn, Co, Cu, Zn, Se) in blood serum of patients with hypothyroidism (Hy group) and healthy people (control group), in order to set the experimental conditions for accurate determination of a unique profile of these elements in hypothyroidism. Method validation was performed with standard reference material of the serum by varying the sample treatment with both standard and collision mode for analysis of elements isotopes. Quadratic curvilinear functions with good performances of models and the lowest detection limits were obtained for 52 Cr, 66 Zn, 75 As, 112 Cd in collision mode, and 55 Mn, 59 Co, 60 Ni, 65 Cu, 78 Se in standard mode. Treatment of serum samples with aqueous solution containing nitric acid, Triton X-100 and n-butanol gave the best results. Chemometric tools were applied for discrimination of patients with hypothyroidism. All nine elements discriminated Hy group of samples with almost the same discriminating power as indicated by their higher values for this group of patients. Statistically significant correlation (p < 0.01) was observed for several elements. Results indicated clear differences in element profile between Hy and control group and it could be used as a unique profile of hypothyroid state. Copyright © 2018 Elsevier GmbH. All rights reserved.
Taheri, Salman; Jalali, Fahimeh; Fattahi, Nazir; Jalili, Ronak; Bahrami, Gholamreza
2015-10-01
Dispersive liquid-liquid microextraction based on solidification of floating organic droplet was developed for the extraction of methadone and determination by high-performance liquid chromatography with UV detection. In this method, no microsyringe or fiber is required to support the organic microdrop due to the usage of an organic solvent with a low density and appropriate melting point. Furthermore, the extractant droplet can be collected easily by solidifying it at low temperature. 1-Undecanol and methanol were chosen as extraction and disperser solvents, respectively. Parameters that influence extraction efficiency, i.e. volumes of extracting and dispersing solvents, pH, and salt effect, were optimized by using response surface methodology. Under optimal conditions, enrichment factor for methadone was 134 and 160 in serum and urine samples, respectively. The limit of detection was 3.34 ng/mmL in serum and 1.67 ng/mL in urine samples. Compared with the traditional dispersive liquid-liquid microextraction, the proposed method obtained lower limit of detection. Moreover, the solidification of floating organic solvent facilitated the phase transfer. And most importantly, it avoided using high-density and toxic solvents of traditional dispersive liquid-liquid microextraction method. The proposed method was successfully applied to the determination of methadone in serum and urine samples of an addicted individual under methadone therapy. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development of a novel protein chip for the detection of bluetongue virus in China.
Xu, Q Y; Sun, E C; Feng, Y F; Li, J P; Lv, S; Zhang, Q; Wang, H X; Zhang, J K; Wu, D L
2016-08-01
Bluetongue (BT), which is caused by the BT virus (BTV), is an important disease in ruminants that leads to significant economic losses in the husbandry industry. To detect BTV-specific antibodies in serum, a protein chip detection method based on a novel solid supporting material known as polymer-coated initiator-integrated poly (dimethyl siloxane) (iPDMS) was developed. With a threshold of 25% (signal-to-noise percentage), the sensitivity and specificity of the protein chip were 98.6% and 94.8%, respectively. Furthermore, spot serum samples obtained from six provinces of China were tested with the protein chip and a commercially available BTV enzyme-linked immunosorbent assay (ELISA) kit (IDEXX). Of 615 samples, BTV-specific antibodies were detected in 200 (32.52%) by the protein chip and in 176 (28.62%) by the IDEXX BTV ELISA kit. Comparison of the protein chip with the commercial IDEXX BTV ELISA kit yielded the following spot serum detection results: a total coincidence, a negative coincidence and a positive coincidence of 95.12%, 99.28% and 86.5%, respectively. With the protein chip, the BTV-specific serum antibody was detected in samples from all six provinces, and the positive rates ranged from 4.12 to 74.4%. These results indicate that this protein chip detection method based on iPDMS is useful for the serological diagnosis of BTV infection and for epidemiological investigation. Copyright © 2016. Published by Elsevier B.V.
Davarcı, I; Karcıoğlu, M; Tuzcu, K; İnanoğlu, K; Yetim, T D; Motor, S; Ulutaş, K T; Yüksel, R
2015-01-01
To compare the effects of pneumoperitoneum on lung mechanics, end-tidal CO2 (ETCO2), arterial blood gases (ABG), and oxidative stress markers in blood and bronchoalveolar lavage fluid (BALF) during laparoscopic cholecystectomy (LC) by using lung-protective ventilation strategy. Forty-six patients undergoing LC and abdominal wall hernia (AWH) surgery were assigned into 2 groups. Measurements and blood samples were obtained before, during pneumoperitoneum, and at the end of surgery. BALF samples were obtained after anesthesia induction and at the end of surgery. Peak inspiratory pressure, ETCO2, and pCO2 values at the 30th minute were significantly increased, while there was a significant decrease in dynamic lung compliance, pH, and pO2 values in LC group. In BALF samples, total oxidant status (TOS), arylesterase, paraoxonase, and malondialdehyde levels were significantly increased; the glutathione peroxidase levels were significantly decreased in LC group. The serum levels of TOS and paraoxonase were significantly higher at the end of surgery in LC group. In addition, arylesterase level in the 30th minute was increased compared to baseline. Serum paraoxonase level at the end of surgery was significantly increased when compared to AWH group. Our study showed negative effects of pneumoperitoneum in both lung and systemic levels despite lung-protective ventilation strategy.
Zhang, Dan; Wang, Xiaolin; Liu, Man; Zhang, Lina; Deng, Ming; Liu, Huichen
2015-01-01
A rapid, sensitive and accurate ICP-MS method using alternate analyte-free matrix for calibration standards preparation and a rapid direct dilution procedure for sample preparation was developed and validated for the quantification of exogenous strontium (Sr) from the drug in human serum. Serum was prepared by direct dilution (1:29, v/v) in an acidic solution consisting of nitric acid (0.1%) and germanium (Ge) added as internal standard (IS), to obtain simple and high-throughput preparation procedure with minimized matrix effect, and good repeatability. ICP-MS analysis was performed using collision cell technology (CCT) mode. Alternate matrix method by using distilled water as an alternate analyte-free matrix for the preparation of calibration standards (CS) was used to avoid the influence of endogenous Sr in serum on the quantification. The method was validated in terms of selectivity, carry-over, matrix effects, lower limit of quantification (LLOQ), linearity, precision and accuracy, and stability. Instrumental linearity was verified in the range of 1.00-500ng/mL, corresponding to a concentration range of 0.0300-15.0μg/mL in 50μL sample of serum matrix and alternate matrix. Intra- and inter-day precision as relative standard deviation (RSD) were less than 8.0% and accuracy as relative error (RE) was within ±3.0%. The method allowed a high sample throughput, and was sensitive and accurate enough for a pilot bioequivalence study in healthy male Chinese subjects following single oral administration of two strontium ranelate formulations containing 2g strontium ranelate. Copyright © 2014 Elsevier GmbH. All rights reserved.
Hsu, Te-Yao; Hsieh, T'sang-T'ang; Yang, Kuender D; Tsai, Ching-Chang; Ou, Chia-Yu; Cheng, Bi-Hua; Wong, Yi-Hsun; Hung, Hsuan-Ning; Chou, An-Kuo; Hsiao, Chang-Chun; Lin, Hao
2015-10-01
Preeclampsia is a major cause of mortality in pregnant women but the underlying mechanism remains unclear to date. In this study, we attempted to identify candidate proteins that might be associated with preeclampsia in pregnant women by means of proteomics tools. Differentially expressed proteins in serum samples obtained from pregnant women with severe preeclampsia (n = 8) and control participants (n = 8) were identified using two-dimensional gel electrophoresis (2-DE) followed by peptide mass fingerprinting using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS). Additional serum samples from 50 normal and 41 pregnant women with severe preeclampsia were analyzed by immunoassay for validation. Ten protein spots were found to be upregulated significantly in women with severe preeclampsia. These protein spots had the peptide mass fingerprints matched to α1-antitrypsin, α1-microglobulin, clusterin, and haptoglobin. Immunoassays in an independent series of serum samples showed that serum α1-antitrypsin, α1-microglobulin, and clusterin levels of severe preeclampsia patients (n = 41) were significantly higher than those in the normal participants (n = 50; α1-antitrypsin 295.95 ± 50.94 mg/dL vs. 259.31 ± 33.90 mg/dL, p = 0.02; α1-microglobulin 0.029 ± 0.004 mg/mL vs. 0.020 ± 0.004 mg/mL, p < 0.0001; clusterin 77.6 ± 16.15 μg/dL vs. 67.6 ± 15.87 μg/dL, p < 0.05). Identification of these proteins by proteomics analysis enables further understanding of the pathophysiology of preeclampsia. Further studies are warranted to investigate the role of these biomarkers in prediction of this disease. Copyright © 2015. Published by Elsevier B.V.
Analysis of lysergic acid amide in human serum and urine after ingestion of Argyreia nervosa seeds.
Paulke, Alexander; Kremer, Christian; Wunder, Cora; Toennes, Stefan W
2012-08-01
The ergot alkaloid lysergic acid amide (LSA) is a secondary plant constituent in a number of plants, but it is mainly present in considerable amounts in Convolvulaceae, like Argyreia nervosa. Due to its close structural similarity to lysergic acid diethylamide, LSA is considered as psychedelic and therefore promoted as so-called "legal high" in various internet forums. During a human behavioral study with orally administered seeds of A. nervosa, blood and urine samples were obtained. The present study describes the validation of a sensitive and robust high performance liquid chromatography method with fluorescence detection, which was applied to the study samples. The limit of detection (LOD) and lower limit of quantification in human serum were 0.05 and 0.17 ng/mL, respectively, and in urine, the LOD was 0.15 ng/mL. Intra- and interday precision and accuracy were below 15 % relative standard deviation with a bias better than ±15 %. No conversion of LSA to its epimer iso-LSA was noted during analyses. The LSA concentrations in the authentic human serum samples were in the range of 0.66 to 3.15 ng/mL approximately 2 h after ingestion. In urine, LSA could be found 1-24 h after ingestion; after 48 h, no LSA could be detected. The LSA epimer iso-LSA was also detected in serum and urine in varying ratios. In conclusion, LSA serum levels in the low nanogram per milliliter range correlated with severe vegetative adverse effects (nausea, weakness, fatigue, tremor, blood pressure elevation) and a psychosis-like state, which led to study termination.
Shao, Stephanie; Neely, Benjamin A; Kao, Tzu-Cheg; Eckhaus, Janet; Bourgeois, Jolie; Brooks, Jasmin; Jones, Elizabeth E; Drake, Richard R; Zhu, Kangmin
2017-05-01
Background: Serum proteomic biomarkers offer a promising approach for early detection of cancer. In this study, we aimed to identify proteomic profiles that could distinguish colon cancer cases from controls using serial prediagnostic serum samples. Methods: This was a nested case-control study of active duty military members. Cases consisted of 264 patients diagnosed with colon cancer between 2001 and 2009. Controls were matched to cases on age, gender, race, serum sample count, and collection date. We identified peaks that discriminated cases from controls using random forest data analysis with a 2/3 training and 1/3 validation dataset. We then included epidemiologic data to see whether further improvement of model performance was obtainable. Proteins that corresponded to discriminatory peaks were identified. Results: Peaks with m/z values of 3,119.32, 2,886.67, 2,939.23, and 5,078.81 were found to discriminate cases from controls with a sensitivity of 69% and a specificity of 67% in the year before diagnosis. When smoking status was included, sensitivity increased to 76% while histories of other cancer and tonsillectomy raised specificity to 76%. Peaks at 2,886.67 and 3,119.32 m/z were identified as histone acetyltransferases while 2,939.24 m/z was a transporting ATPase subunit. Conclusions: Proteomic profiles in the year before cancer diagnosis have the potential to discriminate colon cancer patients from controls, and the addition of epidemiologic information may increase the sensitivity and specificity of discrimination. Impact: Our findings indicate the potential value of using serum prediagnostic proteomic biomarkers in combination with epidemiologic data for early detection of colon cancer. Cancer Epidemiol Biomarkers Prev; 26(5); 711-8. ©2016 AACR . ©2016 American Association for Cancer Research.
Ahn, Joong Kyong; Kim, Jungyeon; Hwang, Jiwon; Song, Juhwan; Kim, Kyoung Heon; Cha, Hoon-Suk
2018-05-01
Although many diagnostic criteria of Behcet's disease (BD) have been developed and revised by experts, diagnosing BD is still complicated and challenging. No metabolomic studies on serum have been attempted to improve the diagnosis and to identify potential biomarkers of BD. The purposes of this study were to investigate distinctive metabolic changes in serum samples of BD patients and to identify metabolic candidate biomarkers for reliable diagnosis of BD using the metabolomics platform. Metabolomic profiling of 90 serum samples from 45 BD patients and 45 healthy controls (HCs) were performed via gas chromatography with time-of-flight mass spectrometry (GC/TOF-MS) with multivariate statistical analyses. A total of 104 metabolites were identified from samples. The serum metabolite profiles obtained from GC/TOF-MS analysis can distinguish BD patients from HC group in discovery set. The variation values of the partial least squared-discrimination analysis (PLS-DA) model are R 2 X of 0.246, R 2 Y of 0.913 and Q 2 of 0.852, respectively, indicating strong explanation and prediction capabilities of the model. A panel of five metabolic biomarkers, namely, decanoic acid, fructose, tagatose, linoleic acid and oleic acid were selected and adequately validated as putative biomarkers of BD (sensitivity 100%, specificity 97.1%, area under the curve 0.998) in the discovery set and independent set. The PLS_DA model showed clear discrimination of BD and HC groups by the five metabolic biomarkers in independent set. This is the first report on characteristic metabolic profiles and potential metabolite biomarkers in serum for reliable diagnosis of BD using GC/TOF-MS. Copyright © 2017. Published by Elsevier SAS.
Lanshoeft, Christian; Heudi, Olivier; Cianférani, Sarah
2016-05-15
The newly developed SMART Digest™ kit was applied for the sample preparation of human immunoglobulin G1 (hIgG1) in rat serum prior to qualitative and quantitative analyses by liquid chromatography tandem mass spectrometry (LC-MS/MS). The sequence coverages obtained for the light and heavy chains of hIgG1A were 50 and 76%, respectively. The calibration curve was linear from 1.00 to 1000 μg/ml for three of four generic peptides. Overall, the SMART Digest™ kit resulted in similar quantitative data (linearity, sensitivity, accuracy, and precision) compared with the pellet digestion protocol. However, the SMART Digest™ required only 2 h of sample preparation with fewer reagents. Copyright © 2016 Elsevier Inc. All rights reserved.
López Uriarte, Graciela Arelí; Burciaga Flores, Carlos Horacio; Torres de la Cruz, Víctor Manuel; Medina Aguado, María Magdalena; Gómez Puente, Viviana Maricela; Romero Gutiérrez, Liliana Nayeli; Martínez de Villarreal, Laura Elia
2018-06-01
Prenatal diagnosis of Down syndrome (DS) is based on the calculated risk of maternal age, biochemical and ultrasonographic markers and recently by cfDNA. Differences in proteomic profiles may give an opportunity to find new biomarkers. Characterize proteome of serum of mothers carrying DS fetus. Blood serum samples of three groups of women were obtained, (a) 10 non-pregnant, (b) 10 pregnant with healthy fetus by ultrasound evaluation, (c) nine pregnant with DS fetus. Sample preparation was as follows: Albumin/IgG depletion, desalting, and trypsin digestion; the process was performed in nanoUPLC MS/MS. Data analysis was made with Mass Lynx 4.1 and ProteinLynx Global Server 3.0, peptide and protein recognition by MASCOT algorithm and UNIPROT-Swissprot database. Each group showed different protein profiles. Some proteins were shared between groups. Only sera from pregnant women showed proteins related to immune and clot pathways. Mothers with DS fetus had 42 specific proteins. We found a different serum protein profile in mothers carrying DS fetuses that do not reflect expression of genes in the extra chromosome. Further studies will be necessary to establish the role of these proteins in aneuploid fetus and analyze their possible use as potential biomarkers.
YAMAMOTO, Kenya; KUDO, Mitsuhiro; ARITO, Heihachiro; OGAWA, Yasutaka; TAKATA, Tsutomu
2015-01-01
This cross-sectional study was intended to examine health effects of 678 male workers employed during an 8-yr period from 2000 to 2007 at 36 municipal and private waste incineration plants in Japan. Blood samples were obtained for analysis of concentrations of dioxins including coplanar polychlorinated biphenyls (coplanar PCBs) and evaluation of health effects. Health effects including diabetes were surveyed via a physician’s interview or clinical data from blood samples. There was a certain difference in serum concentrations of polychlorinated dibenzofurans (PCDFs) between the incinerator workers and Japanese general population, although no differences in the concentrations of total dioxins or polychlorinated dibenzo-p-dioxins (PCDDs) were found between the two groups. A few positive correlations between serum levels of PCDDs and PCDFs and the results of laboratory and physiological tests were found, but coplanar PCBs showed significant relations with 14 parameters of the tests. The background serum levels of PCDDs, PCDFs and total dioxins were significantly associated with the prevalence of diabetes. No essential differences in serum concentrations of total dioxins and in prevalence of diabetes between our subjects and the general population suggested that the incinerator workers were marginally exposed to dioxins in the workplace without any recognizable adverse health effects. PMID:26212412
Alderete, J F
1984-06-01
An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses during the development of lesions in animals inoculated subcutaneously and it reproducibly measured the individual classes immunoglobulins directed at T vaginalis. The colorimetric assay was also suitable for showing cross reactivity between trichomonal species as well as between different strains of T vaginalis. Conditions established for monitoring antibody to trichomanads in immunised rabbits or infected mice were equally effective for human materials, such as serum or vaginal washes. Serum from experimental animals or infected people showed high concentrations of IgG, IgA, and IgM antibody to trichomonads. Only antibodies of the IgG and IgA class were detected in vaginal washes from women with acute trichomoniasis. No IgE antibody to trichomonads was found under a variety of conditions in serum samples from patients or experimental animals.
NASA Astrophysics Data System (ADS)
Liao, Fadian; Ruan, Qiuyong; Lin, Juqiang; Lin, Jinyong; Zeng, Yongyi; Li, Ling; Huang, Zufang; Liu, Nenrong; Chen, Rong
2014-09-01
Despite the introduction of high-technology methods of detection and diagnosis, screening of primary liver cancer (PLC) remains imperfect. To diagnosis PLC earlier, Surface-enhanced Raman spectroscopy (SERS) coupled with cellulose-acetate membrane electrophoresis were introduced to separate human serum albumin and SERS spectra. Three groups (15 normal persons' samples, 17 hepatitis/cirrhosis samples, 15 cases of PLC) of serum albumin were tested. Silver colloid was used to obtain SERS spectra of human serum albumin. Principal component analysis (PCA) and linear discriminant analysis (LDA) were also employed for statistical analysis. The mean Raman spectra of three groups and the difference spectra of any two suggested that the albumin has changed in liver patients. Compared to normal groups, some Raman peaks have shifted or even disappeared in hepatitis/cirrhosis and PLCs groups. The sensitivity and specificity between PLCs and normal groups is 80% and 93.3%. Among hepatitis/cirrhosis and normal groups, the sensitivity is 88.2% and specificity is also 93.3%. Besides, the sensitivity and specificity between PLCs and hepatitis/cirrhosis groups is 86.7% and 76.5%. All the above data and results indicated that early screening of PLC is potential by SERS in different stages of liver disease before cancer occurs.
Austdal, Marie; Tangerås, Line H; Skråstad, Ragnhild B; Salvesen, Kjell; Austgulen, Rigmor; Iversen, Ann-Charlotte; Bathen, Tone F
2015-09-08
Hypertensive disorders of pregnancy, including preeclampsia, are major contributors to maternal morbidity. The goal of this study was to evaluate the potential of metabolomics to predict preeclampsia and gestational hypertension from urine and serum samples in early pregnancy, and elucidate the metabolic changes related to the diseases. Metabolic profiles were obtained by nuclear magnetic resonance spectroscopy of serum and urine samples from 599 women at medium to high risk of preeclampsia (nulliparous or previous preeclampsia/gestational hypertension). Preeclampsia developed in 26 (4.3%) and gestational hypertension in 21 (3.5%) women. Multivariate analyses of the metabolic profiles were performed to establish prediction models for the hypertensive disorders individually and combined. Urinary metabolomic profiles predicted preeclampsia and gestational hypertension at 51.3% and 40% sensitivity, respectively, at 10% false positive rate, with hippurate as the most important metabolite for the prediction. Serum metabolomic profiles predicted preeclampsia and gestational hypertension at 15% and 33% sensitivity, respectively, with increased lipid levels and an atherogenic lipid profile as most important for the prediction. Combining maternal characteristics with the urinary hippurate/creatinine level improved the prediction rates of preeclampsia in a logistic regression model. The study indicates a potential future role of clinical importance for metabolomic analysis of urine in prediction of preeclampsia.
Zeng, Jie; Qi, Tianqi; Wang, Shu; Zhang, Tianjiao; Zhou, Weiyan; Zhao, Haijian; Ma, Rong; Zhang, Jiangtao; Yan, Ying; Dong, Jun; Zhang, Chuanbao; Chen, Wenxiang
2018-04-25
The aim of the current study was to evaluate the commutability of commercial control materials and human serum pools and to investigate the suitability of the materials for the external quality assessment (EQA) of serum apolipoprotein A-I (apo A-I) measurement. The Clinical and Laboratory Standards Institute (CLSI) EP14-A3 protocol was used for the commutability study. Apo A-I concentrations in two levels of commercial control materials used in EQA program, two fresh-frozen human serum pools (FSPs) and two frozen human serum pools prepared from residual clinical specimens (RSPs) were measured along with 50 individual samples using nine commercial assays. Measurement results of the 50 individual samples obtained with different assays were pairwise analyzed by Deming regression, and 95% prediction intervals (PIs) were calculated. The commutability of the processed materials was evaluated by comparing the measurement results of the materials with the limits of the PIs. The FSP-1 was commutable for all the 36 assay pairs, and FSP-2 was commutable for 30 pairs; RSP-1 and RSP-2 showed commutability for 27/36 and 22/36 assay pairs, respectively, whereas the two EQA materials were commutable only for 4/36 and 5/36 assay pairs, respectively. Non-commutability of the tested EQA materials has been observed among current apo A-I assays. EQA programs need either to take into account the commutability-related biases in the interpretation of the EQA results or to use more commutable materials. Frozen human serum pools were commutable for most of the assays.
Cells and biofluids analyzed in aqueous environment by infrared spectroscopy
NASA Astrophysics Data System (ADS)
Naumann, D.; Lasch, P.; Fabian, H.
2006-02-01
Infrared transmission/absorption measurements of cells and biofluids in water are restricted to very short optical pathlengths. When the amide I and amide II bands of protein constituents have to be analysed, path-lengths of less than 8 μm are necessary. Infrared spectra of cancer cells were collected from physiological buffer solutions utilizing custom-made mid-infrared compatible IR-cuvettes. The technology permitted to obtain cell-type specific spectral signatures and probe biochemical changes induced by varying temperatures or cell-drug interaction. Optical path-lengths of 8-30 μm were used on a set of microbial test strains to evaluate, whether the methodology can also be used to discriminate and identify micro-organisms. A semi-automatic methodology was developed for the analysis of liquid serum samples, which combines simple sample handling with high sample throughput and extreme measurement reproducibility. The applicability of this infrared technology to the analysis of liquid serum samples from cattle and human beings suffering from various acute viral or bacterial infections was explored testing the interrelationship between α-helical and β-sheet specific spectral signatures in the amide I band contour and total albumin and globulin content in serum. The technical details, advantages, and limitations of the new technology are described in the context of developing a routine, IR-based biodiagnostic technique for biofluids and biological cells.
Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah
2015-01-01
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1 and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum. PMID:26330859
Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum.
Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah
2015-01-01
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1) and 2-20 μg mL(-1) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum.
Ratti, H; Zhang, M; Kunkel, G
2001-03-02
Neutral endopeptidase (NEP) is described in airways as the major degrading enzyme of tachykinins such as neurokinin A (NKA) and substance P (SP). Due to its localization and mode of action NEP may play a role in the pathophysiology of bronchial reactivity (BR) especially under the aspect of neurogenic inflammation. Serum NEP concentrations were measured by ELISA to investigate if there is a correlation between serum NEP and the degree of bronchial reactivity expressed by PC20-FEV1 histamine(.). PC20-FEV1 histamine was determined in 31 asthmatic patients [age 31.9+/-1.3 years (mean+/-SEM) FEV1=92.1+/-2.4% (mean+/-SEM) 16 females/15 males]. Prior to the histamine challenge blood samples were obtained and stored at -70 degrees C until determination using ELISA. A significant correlation between serum NEP and the PC20-FEV1 (n=31, r=0.49, P<0.01) was found. The results suggest that serum NEP is modulating neuropeptide-induced effects in the pathophysiology of airway responsiveness.
Prüller, Florian; Wagner, Jasmin; Raggam, Reinhard B; Hoenigl, Martin; Kessler, Harald H; Truschnig-Wilders, Martie; Krause, Robert
2014-07-01
Testing for (1→3)-beta-D-glucan (BDG) is used for detection of invasive fungal infection. However, current assays lack automation and the ability to conduct rapid single-sample testing. The Fungitell assay was adopted for automation and evaluated using clinical samples from patients with culture-proven candidemia and from culture-negative controls in duplicate. A comparison with the standard assay protocol was made in order to establish analytical specifications. With the automated protocol, the analytical measuring range was 8-2500 pg/ml of BDG, and precision testing resulted in coefficients of variation that ranged from 3.0% to 5.5%. Samples from 15 patients with culture-proven candidemia and 94 culture-negative samples were evaluated. All culture-proven samples showed BDG values >80 pg/ml (mean 1247 pg/ml; range, 116-2990 pg/ml), which were considered positive. Of the 94 culture-negative samples, 92 had BDG values <60 pg/ml (mean, 28 pg/ml), which were considered to be negative, and 2 samples were false-positive (≥80 pg/ml; up to 124 pg/ml). Results could be obtained within 45 min and showed excellent agreement with results obtained with the standard assay protocol. The automated Fungitell assay proved to be reliable and rapid for diagnosis of candidemia. It was demonstrated to be feasible and cost efficient for both single-sample and large-scale testing of serum BDG. Its 1-h time-to-result will allow better support for clinicians in the management of antifungal therapy. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Porcella, Stephen F.; Raffel, Sandra J.; Schrumpf, Merry E.; Schriefer, Martin E.; Dennis, David T.; Schwan, Tom G.
2000-01-01
Human louse-borne relapsing fever occurs in sporadic outbreaks in central and eastern Africa that are characterized by significant morbidity and mortality. Isolates of the causative agent, Borrelia recurrentis, were obtained from the blood of four patients during a recent epidemic of the disease in southern Sudan. The glpQ gene, encoding glycerophosphodiester phosphodiesterase, from these isolates was sequenced and compared with the glpQ sequences obtained from other relapsing-fever spirochetes. Previously we showed that GlpQ of Borrelia hermsii is an immunogenic protein with utility as a serological test antigen for discriminating tick-borne relapsing fever from Lyme disease. In the present work, we cloned and expressed the glpQ gene from B. recurrentis and used recombinant GlpQ in serological tests. Acute- and convalescent-phase serum samples obtained from 42 patients with louse-borne relapsing fever were tested with an indirect immunofluorescence assay (IFA) and an enzyme-linked immunosorbent assay (ELISA) that used whole cells of B. recurrentis and with immunoblotting to whole-cell lysates of the spirochete and Escherichia coli producing recombinant GlpQ. The geometric mean titers of the acute- and convalescent-phase serum samples measured by IFA were 1:83 and 1:575, respectively. The immunoblot analysis identified a high level of reactivity and seroconversion to GlpQ, and the assay was more sensitive than the whole-cell IFA and ELISA using purified, recombinant histidine-tagged GlpQ. Serum antibodies to GlpQ and other antigens persisted for 27 years in one patient. We conclude that assessment of anti-GlpQ antibodies will allow serological confirmation of louse-borne relapsing fever and determination of disease prevalence. PMID:11015364
Díaz-Llano, G; Smith, T K; Boermans, H J; Caballero-Cortes, C; Friendship, R
2010-03-01
A study was conducted to assess the effects of feeding a blend of grains naturally contaminated with Fusarium mycotoxins to sows on the capacity for protein synthesis in skeletal muscle, the protein content per cellular unit, and the efficacy of a polymeric glucomannan adsorbent (GMA) to prevent these effects in late gestation and in lactation. Thirty-two Yorkshire sows were assigned to 4 treatment groups (8 per treatment) from 91 +/- 3 d of gestation up to weaning on d 21 after farrowing. Diets included 1) control, 2) contaminated grains, and 3) contaminated grains + 0.2% GMA. A fourth treatment of feeding sows the control diet at a restricted feed allowance was also included. The variables measured include ADFI, average daily BW change, serum total protein, urea, and ammonia, and skeletal muscle DNA, RNA, and protein. To assess the capacity for protein synthesis, ratios of RNA:DNA, and RNA:protein were compared among dietary treatments. To assess the degree of muscle protein mobilization in gestation and lactation, ratios of protein:DNA were compared among dietary treatments. Muscle samples were obtained from the triceps brachii. Blood and muscle samples were obtained 3 times: the first was obtained 1 d before the sows began to receive the experimental diets (90 +/- 3 d of gestation), a second sample was obtained 14 d later (104 +/- 3 d of gestation), and the third sample was obtained 10 d after farrowing. Serum ammonia concentrations were similar in sows fed the contaminated feed and sows fed the restricted feed compared with controls, but serum ammonia concentrations were greater in sows fed contaminated feed (P = 0.02) and restricted-fed sows (P = 0.008) compared with sows fed the contaminated grains plus GMA on 104 +/- 3 d of gestation. There were no reductions in the capacity for protein synthesis caused by mycotoxins or restricted feeding compared with controls. A reduction in ADFI (P = 0.003) was observed in sows fed the 2 contaminated diets in lactation. Muscle protein mobilization was not affected by diet, but a reduction (P = 0.04) in the content of protein per cellular unit was observed in lactation compared with gestation. Reduction in protein:DNA could be caused by the catabolic state in lactation, which was augmented by a low ADFI. The rate of muscle mobilization could be the result of the indirect effect of the reduction in ADFI in lactation rather than a direct effect of Fusarium mycotoxins in the capacity for protein synthesis.
Nosocomial Outbreak of Parechovirus 3 Infection among Newborns, Austria, 2014.
Strenger, Volker; Diedrich, Sabine; Boettcher, Sindy; Richter, Susanne; Maritschnegg, Peter; Gangl, Dietmar; Fuchs, Simone; Grangl, Gernot; Resch, Bernhard; Urlesberger, Berndt
2016-09-01
In 2014, sepsis-like illness affected 9 full-term newborns in 1 hospital in Austria. Although results of initial microbiological testing were negative, electron microscopy identified picornavirus. Archived serum samples and feces obtained after discharge were positive by PCR for human parechovirus 3. This infection should be included in differential diagnoses of sepsis-like illness in newborns.
Murata, Kenji; Kanno, Shunsuke; Nishio, Hisanori; Saito, Mitsumasa; Tanaka, Tamami; Yamamura, Kenichiro; Sakai, Yasunari; Takada, Hidetoshi; Miyamoto, Tomofumi; Mizuno, Yumi; Ouchi, Kazunobu; Waki, Kenji; Hara, Toshiro
2014-01-01
Background Kawasaki disease (KD) is a systemic vasculitis of unknown etiology. The innate immune system is involved in its pathophysiology at the acute phase. We have recently established a novel murine model of KD coronary arteritis by oral administration of a synthetic microbe-associated molecular pattern (MAMP). On the hypothesis that specific MAMPs exist in KD sera, we have searched them to identify KD-specific molecules and to assess the pathogenesis. Methods We performed liquid chromatography-mass spectrometry (LC-MS) analysis of fractionated serum samples from 117 patients with KD and 106 controls. Microbiological and LC-MS evaluation of biofilm samples were also performed. Results KD samples elicited proinflammatory cytokine responses from human coronary artery endothelial cells (HCAECs). By LC-MS analysis of KD serum samples collected at 3 different periods, we detected a variety of KD-specific molecules in the lipophilic fractions that showed distinct m/z and MS/MS fragmentation patterns in each cluster. Serum KD-specific molecules showed m/z and MS/MS fragmentation patterns almost identical to those of MAMPs obtained from the biofilms formed in vitro (common MAMPs from Bacillus cereus, Yersinia pseudotuberculosis and Staphylococcus aureus) at the 1st study period, and from the biofilms formed in vivo (common MAMPs from Bacillus cereus, Bacillus subtilis/Bacillus cereus/Yersinia pseudotuberculosis and Staphylococcus aureus) at the 2nd and 3rd periods. The biofilm extracts from Bacillus cereus, Bacillus subtilis, Yersinia pseudotuberculosis and Staphylococcus aureus also induced proinflammatory cytokines by HCAECs. By the experiments with IgG affinity chromatography, some of these serum KD-specific molecules bound to IgG. Conclusions We herein conclude that serum KD-specific molecules were mostly derived from biofilms and possessed molecular structures common to MAMPs from Bacillus cereus, Bacillus subtilis, Yersinia pseudotuberculosis and Staphylococcus aureus. Discovery of these KD-specific molecules might offer novel insight into the diagnosis and management of KD as well as its pathogenesis. PMID:25411968
Vitamins D and A can be successfully measured by LC-MS/MS in cord blood diluted plasma.
Albarhani, Ali A; Collier, Fiona; Greaves, Ronda F; Ponsonby, Anne-Louise; Allen, Katrina J; Vuillermin, Peter J; Roche, Peter; Clarke, Michael W
2015-11-01
In widely used protocols for the collection and isolation of cord blood mononuclear cells, investigators are left with substantial volumes of diluted plasma which could be used for other measurements. The aim of this study was to ascertain the validity of umbilical cord blood (UCB) diluted plasma samples for vitamin D, A and E analysis compared to UCB serum samples. Twenty UCB matched samples of diluted plasma and serum were collected. The samples were analysed by two liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods on two separate occasions. The results of 25(OH)D3 obtained by the two laboratories demonstrated close agreement with a mean difference of 0.14nmol/L [95% confidence interval (95% CI), -6.8 to 7.1]. Both methods demonstrate close agreement for 25(OH)D3 in UCB serum versus diluted UCB plasma; mean difference 2.2nmol/L [95% CI, -9.5 to 13.9] and 4.1nmol/L [95% CI, -14.5 to 6.1] for the results from Lab A and Lab B, respectively. Vitamin A was quantified by Lab A in UCB serum and diluted UCB plasma; mean difference 0.07μmol/L [95% CI, -0.41 to 0.28]. Results of 25(OH)D3 epimer and vitamin E in the diluted UCB plasma were below the limit of quantification, and could not be compared with UCB serum. Diluted UCB plasma can be used for the quantification of retinol and 25(OH)D3 by LC-MS/MS. By contrast, quantification of 25(OH)D3 epimer and vitamin E in diluted UCB plasma is not supported by this study due to limitations in analytical sensitivity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Can serums be replaced by Mueller-Hinton agar in germ tube test?
Atalay, M A; Koc, A N; Parkan, O M; Aydemir, G; Elmali, F; Sav, H
2017-01-01
The germ tube test (GTT) is inexpensive, easy, and well-defined test that differentiates Candida albicans (excluding Candida dubliniensis and Candida africana) from other species. The aim of this study was to evaluate various serums (i.e., human, rabbit, horse, and fetal bovine serum) used in the GTT and Mueller-Hinton agar (MHA). Fifty species isolated from various clinical samples that were defined as C. albicans by both conventional and DNA sequence analysis methods were included in the study. One to two colonies of C. albicans were mixed into 0.5-1 ml of fetal bovine serum, horse serum, rabbit serum, and human serum. Serums and MHA were incubated at 37°C for GTT. They were removed from the incubator and evaluated after 30 min, 1 h, 2 h, and 3 h of incubation. The GTT was accepted to be positive only if germ tube was 1/2 the width and 3 times the length of the parent yeast cell and with no constriction at the point of origin. When the use of serums and MHA for GTT was statistically evaluated, according to the positive scoring, the best results were obtained with MHA and with rabbit, horse, and fetal bovine serum, respectively. The best definition over time statistically was the third hour. It is suggested that inexpensive MHA is a fast, appropriate, and reliable medium for the probable diagnosis of GTT and C. albicans; however, additional studies are still needed to define other Candida species.
Collicutt, Nancy B; Garner, Bridget; Berghaus, Roy D; Camus, Melinda S; Hart, Kelsey
2015-03-01
Although delays between blood sample collection and analysis are common in veterinary medicine, the effect of prolonged serum-clot contact time on serum glucose concentration is not well established and species differences have not been elucidated. The objective was to investigate the effect of storage time and temperature on serum glucose concentration in stored whole blood samples from horse, dog, alpaca, and sturgeon. Whole blood specimens were divided into 7 no-additive tubes and serum was separated from one sample within one hour, serving as the reference sample. The remaining samples were stored at 4°C and 25°C, then centrifuged and serum glucose measured by automated analysis at 2, 4, and 8 hours postcollection. Glucose concentrations were compared using linear mixed models. The decline in serum glucose concentration for all samples stored at 4°C was not statistically significant, except for the 8-hour samples from sturgeon and dog. At 25°C, serum glucose concentration was comparable to reference values at 2 hours in sturgeon and alpaca, but significantly lower at 4 and 8 hours in those species, and at all time points in equine and canine specimens, being most prominent after 8 hours of storage in canine specimens. Storage at 4°C limits serum glucose decline for at least 4 hours in all species tested and up to 8 hours in specimens of horse and alpaca. At 25°C, serum-clot contact time should not exceed 1 hour in equine and canine samples, and 2 hours in specimens from alpaca and sturgeon. © 2014 American Society for Veterinary Clinical Pathology.
Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R.; Fernandes, Daryl L.; Satsangi, Jack; Spencer, Daniel I. R.
2015-01-01
Introduction Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. Methods 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. Results There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. Conclusions The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures. PMID:25831126
Ventham, Nicholas T; Gardner, Richard A; Kennedy, Nicholas A; Shubhakar, Archana; Kalla, Rahul; Nimmo, Elaine R; Fernandes, Daryl L; Satsangi, Jack; Spencer, Daniel I R
2015-01-01
Serum N-glycans have been identified as putative biomarkers for numerous diseases. The impact of different serum sample tubes and processing methods on N-glycan analysis has received relatively little attention. This study aimed to determine the effect of different sample tubes and processing methods on the whole serum N-glycan profile in both health and disease. A secondary objective was to describe a robot automated N-glycan release, labeling and cleanup process for use in a biomarker discovery system. 25 patients with active and quiescent inflammatory bowel disease and controls had three different serum sample tubes taken at the same draw. Two different processing methods were used for three types of tube (with and without gel-separation medium). Samples were randomised and processed in a blinded fashion. Whole serum N-glycan release, 2-aminobenzamide labeling and cleanup was automated using a Hamilton Microlab STARlet Liquid Handling robot. Samples were analysed using a hydrophilic interaction liquid chromatography/ethylene bridged hybrid(BEH) column on an ultra-high performance liquid chromatography instrument. Data were analysed quantitatively by pairwise correlation and hierarchical clustering using the area under each chromatogram peak. Qualitatively, a blinded assessor attempted to match chromatograms to each individual. There was small intra-individual variation in serum N-glycan profiles from samples collected using different sample processing methods. Intra-individual correlation coefficients were between 0.99 and 1. Unsupervised hierarchical clustering and principal coordinate analyses accurately matched samples from the same individual. Qualitative analysis demonstrated good chromatogram overlay and a blinded assessor was able to accurately match individuals based on chromatogram profile, regardless of disease status. The three different serum sample tubes processed using the described methods cause minimal inter-individual variation in serum whole N-glycan profile when processed using an automated workstream. This has important implications for N-glycan biomarker discovery studies using different serum processing standard operating procedures.
Serum hyaluronic acid in dogs with congenital portosystemic shunts.
Seki, M; Asano, K; Sakai, M; Kanno, N; Teshima, K; Edamura, K; Tanaka, S
2010-05-01
To compare the serum level of hyaluronic acid in dogs with congenital portosystemic shunt with that in healthy dogs and to investigate the perioperative change in serum hyaluronic acid following shunt attenuation. Blood samples were obtained from 29 congenital portosystemic shunt dogs before the operation, and 2 and 4 weeks after the operation from 17 and 7 dogs, respectively. The serum hyaluronic acid level of these dogs was measured and compared with that of 10 healthy beagles. The median preoperative hyaluronic acid level in dogs with congenital portosystemic shunt was significantly elevated compared with that in healthy dogs. Furthermore, the median postoperative hyaluronic acid level significantly decreased compared with the median preoperative levels in congenital portosystemic shunt dogs. In the case of dogs with congenital portosystemic shunt, the reduction of intrahepatic portal blood flow might lower the clearance rate of hyaluronic acid in hepatic sinusoidal endothelial cells, so hyaluronic acid clearance could be improved by attenuation of a shunt vessel. Hence, serum hyaluronic acid levels might be useful to evaluate liver function and also have the potential to evaluate successful attenuation of a shunt vessel in dogs with congenital portosystemic shunt. Further investigations are required to clarify whether serum hyaluronic acid offers significant benefits over existing markers such as serum bile acid or ammonia concentrations.
Anel-López, L; Ortega-Ferrusola, C; Martínez-Rodríguez, C; Álvarez, M; Borragán, S; Chamorro, C; Peña, F J; Anel, L; de Paz, P
2017-01-01
Seminal plasma (SP) plays an important role in the motility, viability and maintenance of the fertilizing capacity of mammalian spermatozoa. This study is the first on brown bear (Ursus arctos) SP components, and has two main objectives: 1) to define the SP composition in bear ejaculate and 2) to identify variations in SP composition in relation to high and low levels of testosterone in serum during the breeding season. Forty-eight sperm samples from 30 sexually mature male brown bears (Ursus arctos) were obtained by electroejaculation, and their serum testosterone levels were assessed to sort the animals into 2 groups (high and low testosterone levels, threshold 5 ng/dl). The biochemical and protein compositions of the SP samples were assessed, and sperm motility was analyzed. We found that lactate dehydrogenase was significantly higher in the low-serum-testosterone samples, while concentrations of lipase and Mg+ values were significantly higher in the high-serum-testosterone samples. In contrast, sperm motility did not significantly differ (P>0.05) between the testosterone level groups (total motility: 74.42.8% in the high-level group vs. 77.1±4.7% in the low-level group). A reference digital model was constructed since there is no information for this wild species. To do this, all gel images were added in a binary multidimensional image and thirty-three spots were identified as the most-repeated spots. An analysis of these proteins was done by qualitative equivalency (isoelectric point and molecular weight) with published data for a bull. SP protein composition was compared between bears with high and low serum testosterone, and three proteins (binder of sperm and two enzymes not identified in the reference bull) showed significant (P<0.05) quantitative differences. We conclude that male bears with high or low serum testosterone levels differs only in some properties of their SP, differences in enzyme LDIP2, energy source LACT2, one protein (similar to BSP1) and Mg ion were identified between these two groups. These data may inform the application of SP to improve bear semen extenders.
IL8 and IL16 levels indicate serum and plasma quality.
Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay
2018-02-09
Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.
NASA Astrophysics Data System (ADS)
Huang, Keke; Li, Ming; Li, Hongmei; Li, Mengwan; Jiang, You; Fang, Xiang
2016-01-01
Ambient ionization (AI) techniques have been widely used in chemistry, medicine, material science, environmental science, forensic science. AI takes advantage of direct desorption/ionization of chemicals in raw samples under ambient environmental conditions with minimal or no sample preparation. However, its quantitative accuracy is restricted by matrix effects during the ionization process. To improve the quantitative accuracy of AI, a matrix reference material, which is a particular form of measurement standard, was coupled to an AI technique in this study. Consequently the analyte concentration in a complex matrix can be easily quantified with high accuracy. As a demonstration, this novel method was applied for the accurate quantification of creatinine in serum by using extractive electrospray ionization (EESI) mass spectrometry. Over the concentration range investigated (0.166 ~ 1.617 μg/mL), a calibration curve was obtained with a satisfactory linearity (R2 = 0.994), and acceptable relative standard deviations (RSD) of 4.6 ~ 8.0% (n = 6). Finally, the creatinine concentration value of a serum sample was determined to be 36.18 ± 1.08 μg/mL, which is in excellent agreement with the certified value of 35.16 ± 0.39 μg/mL.
Abellan, Rosario; Ventura, Rosa; Palmi, Ilaria; di Carlo, Simonetta; Bacosi, Antonella; Bellver, Montse; Olive, Ramon; Pascual, Jose Antonio; Pacifici, Roberta; Segura, Jordi; Zuccaro, Piergiorgio; Pichini, Simona
2008-11-04
Insulin-like growth factor-II (IGF-II), insulin-like growth factor binding proteins (IGFBPs) -2 and -3 and C-terminal telopeptide of type I collagen (ICTP) have been proposed, among others, as indirect biomarkers of the recombinant human growth hormone misuse in sport. An extended intra- and inter-laboratory validation of commercially available immunoassays for biomarkers detection was performed. ELISA assays for total IGF-II, IGFBP-2 and IGFBP-3 (IGF-II/ELISA1: DSLabs, IGFBP-2/ELISA2: Biosource, and IGFBP-3/ELISA3: BioSource) and an EIA assay for ICTP (ICTP/EIA: Orion Diagnostica) were evaluated. The inter- and intra-laboratory precision values were acceptable for all evaluated assays (maximum imprecision of 30% and 66% were found only for the lowest quality control samples of IGF-II and IGFBP-3). Correct accuracy was obtained for all inter-laboratory immunoassays and for IGFBP-2 intra-laboratory immunoassay. The range of concentrations found in serum samples under investigation was always covered by the calibration curves of the studied immunoassays. However, 11% and 15% of the samples felt below the estimated LOQ for IGF-II and ICTP, respectively, in the zone where lower precision was obtained. Although the majority of evaluated assays showed an overall reliability not always suitable for antidoping control analysis, relatively high concordances between laboratory results were obtained for all assays. Evaluated immunoassays were used to measure serum concentrations of IGF-II, IGFBP-2 and -3 and ICTP in elite athletes of various sport disciplines at different moments of the training season; in recreational athletes at baseline conditions and finally in sedentary individuals. Serum IGF-II was statistically higher both in recreational and elite athletes compared to sedentary individuals. Elite athletes showed lower IGFBP-2 and higher IGFBP-3 concentration with respect to recreational athletes and sedentary people. Among elite athletes, serum IGFBP-3 (synchronized swimming), and ICTP (rhythmic gymnastics) concentrations were sport-dependent. Over the training season, within athlete variability was observed for IGFBP-2 in case of taekwondo and IGFBP-2 and -3 in case of weightlifting. Variations due to those aspects should be taken in careful consideration in the hypothesis of setting reference concentration ranges for doping detection.
Changsom, Don; Jiang, Li; Lerdsamran, Hatairat; Iamsirithaworn, Sopon; Kitphati, Rungrueng; Pooruk, Phisanu; Auewarakul, Prasert; Puthavathana, Pilaipan
2017-12-01
The kinetics, longevity, and breadth of antibodies to influenza virus neuraminidase (NA) in archival, sequential serum/plasma samples from influenza A virus (IAV) H5N1 infection survivors and from patients infected with the 2009 pandemic IAV (H1N1) virus were determined using an enzyme-linked lectin-based assay. The reverse-genetics-derived H4N1 viruses harboring a hemagglutinin (HA) segment from A/duck/Shan Tou/461/2000 (H4N9) and an NA segment derived from either IAV H5N1 clade 1, IAV H5N1 clade 2.3.4, the 2009 pandemic IAV (H1N1) (H1N1pdm), or A/Puerto Rico/8/1934 (H1N1) virus were used as the test antigens. These serum/plasma samples were also investigated by microneutralization (MN) and/or hemagglutination inhibition (HI) assays. Neuraminidase-inhibiting (NI) antibodies against N1 NA of both homologous and heterologous viruses were observed in H5N1 survivors and H1N1pdm patients. H5N1 survivors who were never exposed to H1N1pdm virus developed NI antibodies to H1N1pdm NA. Seroconversion of NI antibodies was observed in 65% of the H1N1pdm patients at day 7 after disease onset, but an increase in titer was not observed in serum samples obtained late in infection. On the other hand, an increase in seroconversion rate with the HI assay was observed in the follow-up series of sera obtained on days 7, 14, 28, and 90 after infection. The study also showed that NI antibodies are broadly reactive, while MN and HI antibodies are more strain specific. Copyright © 2017 American Society for Microbiology.
Blood creatinine level in postmortem cases.
Nishida, Atsushi; Funaki, Hironao; Kobayashi, Masaki; Tanaka, Yuka; Akasaka, Yoshihisa; Kubo, Toshikazu; Ikegaya, Hiroshi
2015-05-01
Blood chemical analysis for the diagnosis of diseases in forensic cases should be conducted in the same way as for clinical cases. However, it is sometimes difficult to obtain serum samples in forensic cases because of postmortem changes such as hemolysis and putrefaction. This study aimed to evaluate renal function in postmortem cases by blood creatinine analysis. The blood creatinine level was measured by high performance liquid chromatography (HPLC) using whole blood samples taken from 77 postmortem cases, and the relationships between blood creatinine level, postmortem interval, and cause of death were examined. The median blood creatinine level was found to be 1.15 mg/dL, with no significant differences between blood samples taken from different parts of the body. The blood creatinine level was stable for 3 days after death and gradually increased after that period, in line with a previous study using enzymatic analysis that found the serum creatinine level was stable in the early postmortem period. The blood creatinine level was high in the cases of blunt injury, intoxication, and in deaths caused by fire. This was considered to reflect acute renal dysfunction. However, the postmortem blood creatinine level remained higher than the clinical normal value despite omitting cases with renal dysfunction from the analysis. Therefore, we next investigated the change in postmortem creatinine levels in mice and found that the blood creatinine level increased with the emergence of rigor mortis. Our findings indicate that HPLC is useful in the postmortem evaluation of renal function even in the cases where serum cannot be obtained. However, the presence of rigor mortis should be considered in the evaluation of blood creatinine values. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.
Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H
2013-10-01
Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.
Morandi, Pierre-Alain; Schockmel, Gérard A.; Yerly, Sabine; Burgisser, Philippe; Erb, Peter; Matter, Lukas; Sitavanc, Radan; Perrin, Luc
1998-01-01
A total of 234 pools were prepared from 10,692 consecutive serum samples negative for antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 collected at five virological laboratories (average pool size, 45 serum samples). Pools were screened for the presence of HIV-1 RNA by a modified commercial assay (Amplicor HIV-1 Monitor test) which included an additional polyethylene glycol (PEG) precipitation step prior to purification of viral RNA (PEG Amplicor assay). The sensitivity of this assay for HIV-1 RNA detection in individual serum samples within pools matches that of standard commercial assays for individual serum samples, i.e., 500 HIV-1 RNA copies per ml. Five pools were identified as positive, and each one contained one antibody-negative, HIV-1 RNA-positive serum sample, corresponding to an average of 1 infected sample per 2,138 serum samples. Retrospective analysis revealed that the five HIV-1 RNA-positive specimens originated from individuals who had symptomatic primary HIV-1 infection at the time of sample collection and who were also positive for p24 antigenemia. We next assessed the possibility of performing the prepurification step by high-speed centrifugation (50,000 × g for 80 min) of 1.5-ml pools containing 25 μl of 60 individual serum samples, of which only 1 contained HIV-1 RNA (centrifugation Amplicor assay). The sensitivity of this assay also matches the sensitivities of standard commercial assays for HIV-1 RNA detection in individual serum samples. The results demonstrate that both assays with pooled sera can be applied to the screening of large numbers of serum samples in a time- and cost-efficient manner. PMID:9620372
Oba, M; Miyashita, S; Nishii, R; Koiwa, M; Koyama, H; Ambrose, D J; Dochi, O
2013-03-01
The objective of the study was to determine whether the serum obtained from animals differing in body condition score (BCS) affects in vitro embryo development. After in vitro fertilization, serum obtained from dairy cows of either low (L-BCS; 2.1 ± 0.14 on a scale of 1 to 5) or high BCS (H-BCS; 4.0 ± 0.0), or commercially available bovine serum (control) was added at 5% concentration to the in vitro culture medium. Use of serum obtained from H-BCS cows increased the cleavage rates compared with control serum at both 24 and 48 h after in vitro fertilization (78.3 vs. 71.9% and 79.9 vs. 75.1%, respectively), whereas use of serum obtained from L-BCS cows increased the blastocyst rate compared with control serum at 7d (23.8 vs. 19.1%), but this difference was not evident at 8 or 9 d after in vitro fertilization. As nonesterified fatty acid concentrations were highest in control serum, followed by serum from L-BCS and H-BCS cows (621, 559, and 272 μEq/L, respectively), a high concentration of nonesterified fatty acids might adversely affect the very early stages of embryo development, and its negative effects might be greater immediately after fertilization compared with developmental stages after morula formation. Our findings also indicate that factors promoting early stage embryo development do not necessarily promote blastocyst development. Serum obtained from animals under different physiological conditions may be used for in vitro embryo culture to study the effects of nutritional management of dairy cattle on embryo development. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Abulaizi, Mayinuer; Tomonaga, Takeshi; Satoh, Mamoru; Sogawa, Kazuyuki; Matsushita, Kazuyuki; Kodera, Yoshio; Obul, Jurat; Takano, Shigetsugu; Yoshitomi, Hideyuki; Miyazaki, Masaru; Nomura, Fumio
2011-01-01
We searched for novel tumor markers of pancreatic cancer by three-step serum proteome analysis. Twelve serum abundant proteins were depleted using immunoaffinity columns followed by fractionation by reverse-phase high-performance liquid chromatography. Proteins in each fraction were separated by two-dimensional gel electrophoresis. Then the gel was stained by Coomassie Brilliant Blue. Protein spots in which the expression levels were significantly different between cancer and normal control were identified by LC-MS/MS. One hundred and two spots were upregulated, and 84 spots were downregulated in serum samples obtained from patients with pancreatic cancers, and 58 proteins were identified by mass spectrometry. These candidate proteins were validated using western blot analysis and enzyme-linked immunosorbent assay (ELISA). As a result of these validation process, we could confirm that the serum levels of apolipoprotein A-IV, vitamin D-binding protein, plasma retinol-binding protein 4, and tetranectin were significantly decreased in patients with pancreatic cancer. PMID:22091389
Newman, M J; Light, B A; Weston, A; Tollurud, D; Clark, J L; Mann, D L; Blackmon, J P; Harris, C C
1988-01-01
The presence of serum antibodies to the diol-epoxide DNA adducts of representative polycyclic aromatic hydrocarbons (PAH), chrysene, benz[a]anthracene and benzo[a]pyrene, was determined by ELISA using serum samples obtained from normal healthy individuals. Antibodies that reacted against PAH adducted-DNA, but not against PAH-adducted protein, were found in the serum of approximately 40% of the test individuals. Specificity analysis of the antibodies demonstrated that serological cross-reactions between the benzo[a]pyrene and the chrysene diol-epoxide adducts were present. Similar cross-reactivity between the benz[a]anthracene and the chrysene adducts was observed. Sera containing antibodies that were apparently specific for each of the three PAH-DNA adducts were also identified. The presence of antibodies to PAH-DNA adducts indicates both past exposure to these carcinogenic PAH and their metabolic activation to the DNA damaging metabolites. These antibodies may prove to be useful in both retrospective and prospective epidemiological studies of various diseases associated with PAH exposure. PMID:3392204
The Platelia Aspergillus ELISA in diagnosis of invasive pulmonary aspergilosis (IPA).
Siemann, M; Koch-Dörfler, M
2001-01-01
The sensitivity of a sandwich enzyme-linked immunosorbent assay (ELISA) for detecting Aspergillus galactomannan was evaluated with 66 serum samples and 113 specimens of the respiratory tract obtained from 52 patients with pulmonary diseases. The patients were divided into five groups: proven invasive pulmonary aspergillosis (IPA) (five patients), probable IPA (seven patients), Aspergillus colonization (eight patients) or unlikely Aspergillus infection (27 patients). Another five patients with doubtful diagnostic test results are discussed in detail. The results of the Platelia Aspergillus ELISA (Sanofi Pasteur, Freiburg, Germany) in testing specimens of the respiratory tract were 90% sensitivity in proven (serum 38%), 60% in probable (serum 37%) and 71% in Aspergillus colonization (serum 0%). Furthermore, 85% of the Aspergillus spp. from positive cultures of specimens of the respiratory tract were also detected in the ELISA. A total of 57% of the culture negative specimens of patients with a least one positive culture or proven aspergillosis in a series of specimens were positive in the ELISA.
Annerén, G; Magnusson, C G; Nordvall, S L
1990-01-01
In a previous study on children with Down's syndrome a reduced rate of infections was reported by their parents after the children had received six months' treatment with selenium supplements. In the present study the concentrations of the four IgG subclasses were measured in 29 of these children in samples of serum obtained before and immediately after the period of supplementation and one year after it had finished. Selenium had a significant augmentative effect on the serum concentrations of IgG2 and IgG4, but not of IgG1 and IgG3. This effect was not related to age, as among children over the age of 6 years the serum concentrations of IgG2 and IgG4 had decreased significantly one year after the treatment had been stopped. This study suggests that selenium has an immunoregulatory effect, which might be of importance in both basic research and clinical practice. PMID:2148668
Poljak, M; Bednarik, J; Rednak, K; Seme, K; Kristancic, L; Celan-Lucu, B
1998-01-01
To establish current seroprevalence of human T cell leukaemia/lymphoma virus type I (HTLV-I) infection in some low- and high-risk populations from Slovenia, 10,369 and 869 serum samples collected during Slovenian 1994 unlinked surveys of human immunodeficiency viruses seroprevalence in pregnant women and patients attending venereological outpatient services, respectively, and 219 serum samples collected from Slovenian intravenous drug abusers during 1995 and 1996, were screened for the presence of anti-HTLV-I antibodies using commercial particle agglutination test Serodia HTLV-I (Fujirebio, Tokyo, Japan). Only one sample obtained from a pregnant woman was found repeatedly positive in the screening test. Presence of anti-HTLV-I antibodies in the reactive sample was undoubtedly confirmed with supplemental Western blot test. The prevalence of antibodies to HTLV-I in the Slovenian population might be somewhere between one in 10,000 (0.01%) and one in 15,000 (0.0066%), which is similar or even higher to prevalence rates in other European countries.
Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem
2016-04-01
A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.
Nikolac Gabaj, Nora; Miler, Marijana; Vrtarić, Alen; Hemar, Marina; Filipi, Petra; Kocijančić, Marija; Šupak Smolčić, Vesna; Ćelap, Ivana; Šimundić, Ana-Maria
2018-04-25
The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.
Byrem, T M; Bartlett, P C; Donohue, H; Voisinet, B D; Houseman, J T
2012-11-23
Control of Neospora caninum infection in cattle depends on specific, ante-mortem detection of infected animals and limiting their use as breeding stock or by culling. The objective of the present study was to determine appropriate cut-off values and diagnostic performance of a milk ELISA test using whole and skim milk in a commercial serum ELISA test (IDEXX Neospora Ab). Serum and milk samples were obtained from a total of 475 lactating cows from two herds with and two herds without a previous history of N. caninum-associated abortion. Overall seroprevalence determined by the ELISA was 18.3%. Compared to serum ELISA values, correlation and overall performance assessed by receiver operating characteristic analysis was higher when either whole or skim milk samples were diluted 1:2 compared to undiluted or 1:5 diluted samples. Diagnostic performance for analysis of whole and skim milk was compared at cut-off values that achieved a desired operating characteristic of at least 95% specificity. For whole milk diluted 1:2 and a cut-off of 0.14 (S/P ratio), sensitivity and kappa values were 74.7% (95% CI 64.3-83.4) and 0.70 (95% CI 0.61-0.78), respectively. For skim milk diluted 1:2 and a cut-off of 0.30, sensitivity and kappa values were 77.0% (95% CI 66.8-85.4) and 0.72 (95% CI 0.64-0.80), respectively. Using the selected cut-offs, the IDEXX Neospora Ab Test is equally suited for the analysis of whole and skim milk as a screening tool in neosporosis control programs. Copyright © 2012 Elsevier B.V. All rights reserved.
Anti-complement activities of human breast-milk.
Ogundele, M O
1999-08-01
It has long been observed that the human milk possesses significant anti-inflammatory properties, while simultaneously protecting the infant against many intestinal and respiratory pathogens. There is, however, a paucity of information on the degree and extent of this anti-inflammatory activity. In the present study, the inhibitory effects of different fractions of human milk on serum complement activity were analysed. Colostrum and milk samples from healthy voluntary lactating donors at different postpartum ages were obtained and pooled normal human serum was used as source of complement in a modified CH50 assay. Inherent complement activity in human milk was also investigated by measuring the deposition of an activated C3 fragment on a serum-sensitive bacteria, and by haemolytic assays. Most whole- and defatted-milk samples consistently showed a dose-dependent inhibition of the serum complement activity. This inhibition was greater in mature milk compared to transitional milk samples. It was enhanced by inactivation of milk complement, and diminished by centrifugation of milk samples, which partly removed fat and larger protein components including casein micelles. Inherent complement activity in human milk was also demonstrated by haemolysis of sensitised sheep erythrocytes and deposition of C3 fragments on solid-phase bacteria. These activities were highest in the colostrum and gradually decreased as lactation proceeded. Several natural components abundant in the fluid phase of the human breast-milk have been shown to be inhibitors of complement activation in vitro. Their physiological significance probably reside in their ability to prevent inflammatory-induced tissue damage of the delicate immature gastrointestinal tract of the new-born as well as the mammary gland itself, which may arise from ongoing complement activation.
Implementing self sustained quality control procedures in a clinical laboratory.
Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N
2013-01-01
Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.
Katsoulos, Panagiotis D; Athanasiou, Labrini V; Karatzia, Maria A; Giadinis, Nektarios; Karatzias, Harilaos; Boscos, Constantin; Polizopoulou, Zoe S
2017-12-01
Determination of serum total protein concentration is commonly performed by the biuret method. Refractometric measurement is a faster and less expensive alternative but its accuracy has not been determined in ruminants. The purpose of the study was to compare the serum total protein concentrations in cattle, sheep, and goats measured by the biuret method with those obtained by refractometry. Serum total protein concentration was determined in 120 cattle, 67 sheep, and 58 goat blood samples refractometrically and with the biuret method. The data were analyzed with a paired samples t-test, and Passing and Bablok regression equations and Bland and Altman plots were generated. There was a strong linear relationship between the total protein values determined with the refractometer and the biuret method in cattle, sheep, and goats. The statistical accuracy, which represents a bias correction factor that measures the deviation of the best-fit line from the 45° line through the origin, was 90.63% for cattle, 93.05% for sheep, and 91.76% for goats. The mean protein values determined with the refractometer were significantly lower than those measured with the biuret method in cattle and goats (P < .05) but not in sheep (P > .05). The evaluated refractometer was sufficiently accurate for the determination of serum total proteins in cattle, sheep, and goats, although it cannot be used interchangeably with the biuret method. The RIs should be corrected for negative bias based on the created equations. © 2017 American Society for Veterinary Clinical Pathology.
Gong, Zhong-Ying; Lv, Gao-Peng; Gao, Li-Na; Lu, Yi; Guo, Jie; Zang, Da-Wei
2018-06-13
There are no reliable biomarkers that could evaluate the disease burden in amyotrophic lateral sclerosis (ALS). The aim of our study is to evaluate the changes in cerebrospinal fluid (CSF) and serum neurofilament subunit L (NF-L) in patients with ALS and to analyze the correlations between the levels of NF-L and clinical parameters. CSF and serum samples were obtained from 80 ALS patients and 40 controls. The levels of NF-L in CSF and serum were assessed, and disease progression parameters including duration, revised ALS Functional Rating Scale (ALSFRS-r) score, disease progression rate (DPR), upper motor neuron (UMN) score, and survival were analyzed by registered neurologists. All samples were measured using a commercial enzyme-linked immunosorbent assay. Statistical analyses were performed using Prism software. Compared to the controls, the ALS patients displayed significantly increased levels of NF-L; these values were negatively correlated with the ALSFRS-r score and positively correlated with the decrease in ALSFRS-r score, DPR, and UMN score. There was no correlation between levels of NF-L and duration. In addition, the cumulative survival rate in ALS patients with a low level of NF-L was higher than in patients with a high level of NF-L. NF-L levels increased in CSF and serum of patients with ALS. NF-L may thus be a neurodegenerative biomarker for predicting ALS severity and progression, and the survival of patients with this disease. © 2018 S. Karger AG, Basel.
Helbig, Dorit; Wagner, Andreas; Schubert, Rainer; Jahreis, Gerhard
2009-12-01
Serum gamma-tocopherol is thought to be associated with human health. The dietary influence of tocopherol and fibre-rich black currant seed press residue on serum and stool tocopherol concentration was investigated in a controlled human intervention study. Thirty-six women consumed bread enriched with black currant press residue (4 weeks). The resultant faecal and serum tocopherol concentrations were compared with those after a period consuming control bread without press residue and a normal baseline diet. Fibre intake and excretion, antioxidant capacity (TEAC), and vitamin C concentrations in serum and urine were also determined. Samples were obtained with a 5-day standardised diet at the end of each period. The press residue bread lead to significantly increased beta-, gamma-, delta- and total tocopherol intake, serum alpha-, beta-, gamma- and total tocopherol concentration (with and without lipid adjustment), fibre intake and urinary vitamin C concentration compared to control bread (P<0.05). Faecal excretion of total tocopherols and fibre increased compared to baseline (P<0.05). Fibre intake and excretion influence total tocopherol concentration in lipid-adjusted serum and in stool. The outstandingly high increase of serum gamma-tocopherol concentration through seed press residue consumption could be due to a presumed interruption of the enzymatic tocopherol degradation mechanism by bread constituents.
Increased Serum Oxidative Stress Markers in Women with Uterine Leiomyoma
Santulli, Pietro; Borghese, Bruno; Lemaréchal, Herve; Leconte, Mahaut; Millischer, Anne-Elodie; Batteux, Frédéric
2013-01-01
Background Uterine leiomyomas (fibroids) are the most common gynaecological benign tumors in premenopausal women. Evidences support the role of oxidative stress in the development of uterine leiomyoma. We have analysed oxidative stress markers (thiols, advanced oxidized protein products (AOPP), protein carbonyls and nitrates/nitrites) in preoperative sera from women with histologically proven uterine leiomyoma. Methodology/Principal Findings We conducted a laboratory study in a tertiary-care university hospital. Fifty-nine women with histologically proven uterine leiomyoma and ninety-two leiomyoma-free control women have been enrolled in this study. Complete surgical exploration of the abdominopelvic cavity was performed in each patient. Preoperative serum samples were obtained from all study participants to assay serum thiols, AOPP, protein carbonyls and nitrates/nitrites. Concentrations of serum protein carbonyl groups and AOPP were higher in leiomyoma patients than in the control group (p=0.005 and p<0.001, respectively). By contrast, serum thiol levels were lower in leiomyoma patients (p<0.001). We found positive correlations between serum AOPP concentrations and total fibroids weight (r=0.339; p=0.028), serum AOPP and serum protein carbonyls with duration of infertility (r=0.762; p=0.006 and r=0.683; p=0.021, respectively). Conclusions/Significance This study, for the first time, reveals a significant increase of protein oxidative stress status and reduced antioxidant capacity in sera from women with uterine leiomyoma. PMID:23951284
Serum ischemia modified albumin is a possible new marker of oxidative stress in phenylketonuria.
Keshavarzi, Fatemeh; Rastegar, Mohsen; Vessal, Mahmood; Rafiei Dehbidi, Gholamreza; Khorsand, Marjan; Ganjkarimi, Amir Hossein; Takhshid, Mohammad Ali
2018-06-01
The role of oxidative stress in the pathogenesis of phenylketonuria (PKU)-associated disorders has been implicated. Ischemia modified albumin (IMA) is a modified form of serum albumin, which is produced under the conditions of oxidative stress. The aim of this study was to measure the serum level of IMA in the PKU patients and to investigate its ability in predicting the status of oxidative stress in these patients. Fifty treated-PKU patients and fifty age- and sex-matched healthy subjects were included in the study. The blood samples were obtained and the serum level of phenylalanine (Phe) was measured using reverse phase HPLC method. The levels of IMA, malondialdehyde (MDA), gamma-glutamyl transferase (GGT) activity, and uric acid (UA) were determined using colorimetric methods. The levels of serum Phe, IMA, and MDA were significantly higher (p < 0.001) and the level of UA (p < 0.05) was lower in the PKU patients compared to control group. Serum IMA level was positively correlated with MDA (r = 0.585, p < 0.001) and UA (r = 0.6, p < 0.001). An inverse relationship was observed between the serum level of IMA and Phe (r = - 0.410, p < 0. 01). Results of the present study suggest that serum IMA level could be used as a novel marker for the evaluation of oxidative stress in the PKU patients.
Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin
2014-01-01
Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.
Dukić, Lora; Šimundić, Ana-Maria; Malogorski, Davorin
2014-01-01
Introduction: Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Materials and methods: Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Results: Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Conclusion: Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration. PMID:24627723
Analytical validation of a new point-of-care assay for serum amyloid A in horses.
Schwartz, D; Pusterla, N; Jacobsen, S; Christopher, M M
2018-01-17
Serum amyloid A (SAA) is a major acute phase protein in horses. A new point-of-care (POC) test for SAA (Stablelab) is available, but studies evaluating its analytical accuracy are lacking. To evaluate the analytical performance of the SAA POC test by 1) determining linearity and precision, 2) comparing results in whole blood with those in serum or plasma, and 3) comparing POC results with those obtained using a previously validated turbidimetric immunoassay (TIA). Assay validation. Analytical validation of the POC test was done in accordance with American Society of Veterinary Clinical Pathology guidelines using residual equine serum/plasma and whole blood samples from the Clinical Pathology Laboratory at the University of California-Davis. A TIA was used as the reference method. We also evaluated the effect of haematocrit (HCT). The POC test was linear for SAA concentrations of up to at least 1000 μg/mL (r = 0.991). Intra-assay CVs were 13, 18 and 15% at high (782 μg/mL), intermediate (116 μg/mL) and low (64 μg/mL) concentrations. Inter-assay (inter-batch) CVs were 45, 14 and 15% at high (1372 μg/mL), intermediate (140 μg/mL) and low (56 μg/mL) concentrations. SAA results in whole blood were significantly lower than those in serum/plasma (P = 0.0002), but were positively correlated (r = 0.908) and not affected by HCT (P = 0.261); proportional negative bias was observed in samples with SAA>500 μg/mL. The difference between methods exceeded the 95% confidence interval of the combined imprecision of both methods (15%). Analytical validation could not be performed in whole blood, the sample most likely to be used stall side. The POC test has acceptable accuracy and precision in equine serum/plasma with SAA concentrations of up to at least 1000 μg/mL. Low inter-batch precision at high concentrations may affect serial measurements, and the use of the same test batch and sample type (serum/plasma or whole blood) is recommended. Comparison of results between the POC test and the TIA is not recommended. © 2018 EVJ Ltd.
Foulstone, M; Reading, C
1982-11-01
Augmentin is a new antibacterial formulation comprised of amoxicillin and the beta-lactamase inhibitor clavulanic acid. In the present paper, the use of high-performance liquid chromatography (HPLC) to provide a rapid assay of the components of Augmentin in body fluids is described. Clavulanic acid was assayed by reacting the sample with imidazole, which readily produces a derivative absorbing at 311 nm. This derivative chromatographs on reverse-phase HPLC columns clear of interfering components in both human serum and urine. Concentrations of clavulanic acid as low as 0.1 microgram/ml were readily detectable in human serum with this procedure. There was no interference from amoxicillin, amoxicillin penicilloic acid, or the acid and alkali degradation products of clavulanic acid when this assay system was used. Amoxicillin in body fluids was assayed directly by HPLC without derivatization. The same chromatographic conditions were employed for the assay of amoxicillin and the clavulanic acid derivative, simplifying the methodology. Amoxicillin, however, was determined of the antibiotic per ml. An alkali blanking procedure for amoxicillin and clavulanic acid is also described which allows the detection of any underlying peaks which may cochromatograph. The use of ultrafiltration to remove protein from serum samples before HPLC was successfully applied to the assay of clavulanic acid and amoxicillin. Ultrafiltration is not an essential procedure for these assays, but it prolongs column life and reduces interference in the amoxicillin assay. Results obtained by HPLC were compared with those obtained by using microbiological assays.
Properdin Levels in Individuals with Chemotherapy-Induced Neutropenia.
Tsyrkunou, Artsiom; Agarwal, Sarika; Koirala, Bibek; Finberg, Robert W; Nath, Rajneesh; Barton, Bruce; Levitz, Stuart M; Wang, Jennifer P; Ram, Sanjay
2017-01-01
Neutrophils produce and carry key components of the alternative pathway (AP) of complement, including properdin (P). The effect of chemotherapy-induced absolute neutropenia on circulating P levels and AP function has not been previously established. We prospectively measured free P levels in serum from 27 individuals expected to develop neutropenia after administration of chemotherapy for hematological malignancies in preparation for hematopoietic stem cell transplantation and here describe the relationship between serum P levels and the neutrophil count over time. When the absolute neutrophil count (ANC) was >500 cells/mm 3 pre-chemotherapy, P levels were significantly higher than P levels associated with an ANC ≤500 cells/mm 3 (median values 8392 ng/mL and 6355 ng/mL, respectively; P = .001). Pairwise comparison between pre-chemotherapy P levels and P levels at initial or last documented neutropenia before recovery showed a significant decline ( P < .0001). No correlation was observed between P levels during neutropenia and after recovery of neutropenia in 20 subjects for which postneutropenia samples were obtained. A small but significant ( P = .02) decrease in AP hemolytic activity was noted between baseline (preneutropenia) and samples obtained at the onset of neutropenia, but only with low (6.25%) and not higher (12.5 or 25%) serum concentrations. A decline in P levels and AP activity could contribute to the increased risk of infection in neutropenic patients and warrants further study. © The Author 2016. Published by Oxford University Press on behalf of Infectious Diseases Society of America.
Gunnala, Vishal; Guo, Rong; Minutti, Carla; Durazo-Arvizu, Ramon; Laporte, Cynthia; Mathews, Herbert; Kliethermis, Stephanie; Bhatia, Rahul
2015-05-01
To compare serum total, serum free and salivary cortisol in critically ill children. Prospective observational cohort study. Tertiary pediatric critical care unit at Ronald McDonald Children's Hospital at Loyola University Medical Center. We enrolled 59 patients (4 weeks to 18 years of age) between January 2012 and May 2013. Thirty-four patients were included in the salivary to serum free cortisol correlational analysis. Blood and saliva samples were obtained simultaneously within 24 hours of admission between the hours of 6 AM and 12 PM. Salivary cortisol was tested by liquid chromatography/tandem mass spectrometry, serum free cortisol by liquid chromatography/tandem mass spectrometry followed by equilibrium dialysis, and serum total cortisol by liquid chromatography/tandem mass spectrometry. Salivary and serum free cortisol values from 34 patients had a correlation coefficient (r) of 0.87 (95% CI, 0.75-0.93; p < 0.0001). The total serum and salivary cortisol values had a correlation coefficient (r) of 0.67 (95% CI, 0.42-0.81; p < 0.0001). The total serum and serum free cortisol values had a correlation coefficient (r) of 0.83 (95% CI, 0.69-0.91; p < 0.0001). Serum free and salivary cortisol values correlate in critically ill children. Salivary cortisol can be used as a surrogate for serum free cortisol in critically ill pediatric patients. Salivary cortisol is a cost-effective and less invasive measure of bioavailable cortisol and offers an alternate and accurate method for assessing critical illness-related corticosteroid insufficiency in children.
Gabriel, Frédéric; Gaboyard, Manuel; Lagardere, Gaëlle; Audebert, Lucile; Quesne, Gilles; Godichaud, Sandrine; Verweij, Paul E.; Accoceberry, Isabelle
2017-01-01
ABSTRACT Aspergillus fumigatus is the main species responsible for aspergillosis in humans. The diagnosis of aspergillosis remains difficult, and the rapid emergence of azole resistance in A. fumigatus is worrisome. The aim of this study was to validate the new MycoGENIE A. fumigatus real-time PCR kit and to evaluate its performance on clinical samples for the detection of A. fumigatus and its azole resistance. This multiplex assay detects DNA from the A. fumigatus species complex by targeting the multicopy 28S rRNA gene and specific TR34 and L98H mutations in the single-copy-number cyp51A gene of A. fumigatus. The specificity of cyp51A mutation detection was assessed by testing DNA samples from 25 wild-type or mutated clinical A. fumigatus isolates. Clinical validation was performed on 88 respiratory samples obtained from 62 patients and on 69 serum samples obtained from 16 patients with proven or probable aspergillosis and 13 patients without aspergillosis. The limit of detection was <1 copy for the Aspergillus 28S rRNA gene and 6 copies for the cyp51A gene harboring the TR34 and L98H alterations. No cross-reactivity was detected with various fungi and bacteria. All isolates harboring the TR34 and L98H mutations were accurately detected by quantitative PCR (qPCR) analysis. With respiratory samples, qPCR results showed a sensitivity and specificity of 92.9% and 90.1%, respectively, while with serum samples, the sensitivity and specificity were 100% and 84.6%, respectively. Our study demonstrated that this new real-time PCR kit enables sensitive and rapid detection of A. fumigatus DNA and azole resistance due to TR34 and L98H mutations in clinical samples. PMID:28814586
A Low-Testosterone State Associated with Endometrioma Leads to the Apoptosis of Granulosa Cells
Ono, Yoshihiro J.; Tanabe, Akiko; Nakamura, Yoko; Yamamoto, Hikaru; Hayashi, Atsushi; Tanaka, Tomohito; Sasaki, Hiroshi; Hayashi, Masami; Terai, Yoshito; Ohmichi, Masahide
2014-01-01
Although endometriosis is suspected to be a cause of premature ovarian insufficiency (POI), the mechanism(s) underlying this process have not been elucidated. Recently, androgens were shown to promote oocyte maturation and to play a role in folliculogenesis. In addition, several reports have documented low testosterone levels in the follicular fluid obtained from endometriosis patients. We therefore examined whether the low levels of serum testosterone are associated with the apoptosis of granulosa cells in follicles obtained from endometriosis patients. Serum samples were collected from 46 patients with endometriosis and from 62 patients without endometriosis who received assisted reproductive therapy. Specimens of the ovaries obtained from 10 patients with endometrioma were collected using laparoscopy. The mean serum testosterone concentration in the patients with endometriosis was significantly lower than that observed in the patients without endometriosis. Furthermore, high expression of a pro-apoptotic Bcl-2 member, BimEL, in the follicles was found to be associated with a low serum testosterone level. We clarified the underlying mechanisms using a basic approach employing human immortalized granulosa cells derived from a primary human granulosa cell tumor, the COV434 cell line. The in vitro examination demonstrated that testosterone inhibited apoptosis induced by sex steroids depletion via the PI3K/Akt-FoxO3a pathway in the COV434 cells. In conclusion, we elucidated the mechanism underlying the anti-apoptotic effects of testosterone on granulosa cells, and found that a low-testosterone status is a potentially important step in the development of premature ovarian insufficiency in patients with endometriosis. PMID:25536335
Melatonin in human preovulatory follicular fluid
NASA Technical Reports Server (NTRS)
Brzezinski, Amnon; Seibel, Machelle M.; Lynch, Harry J.; Deng, Mei-Hua; Wurtman, Richard J.
1987-01-01
Melatonin, the major hormone of the pineal gland, has antigonadotrophic activity in many mammals and may also be involved in human reproduction. Melatonin suppresses steroidogenesis by ovarian granulosa and luteal cells in vitro. To determine if melatonin is present in the human ovary, preovulatory follicular fluids (n = 32) from 15 women were assayed for melatonin by RIA after solvent extraction. The fluids were obtained by laparoscopy or sonographically controlled follicular puncture from infertile women undergoing in vitro fertilization and embryo transfer. All patients had received clomiphene citrate, human menopausal gonadotropin, and hCG to stimulate follicle formation. Blood samples were obtained by venipuncture 30 rain or less after follicular aspiration. All of the follicular fluids contained melatonim, in concentrations substantially higher than those in the corresponding serum. A positive correlation was found between follicular fluid and serum melatonin levels in each woman; these observations indicate that preovulatory follicles contain substantial amounts of melatonin that may affect ovarian steroidogenesis.
The diagnostic effect of serum miR-196b as biomarker in colorectal cancer
Xu, Chunjie; Gu, Lei
2017-01-01
The microRNA, miR-196b, serves a role in normal cell differentiation, proliferation and tumorigenesis of different types of cancer. The aim of the present study was to explore the serum expression of miR-196b in colorectal cancer (CRC) and its correlation with clinicopathological features. Sera samples were obtained from 103 patients with CRC, 51 patients with colorectal adenoma (Ad) and 100 healthy individuals for the present study. The serum expression of miR-196b in sera samples of the three cohorts was detected using reverse transcription-quantitative polymerase chain reaction. The diagnostic value of miR-196b in the serum of the patients with CRC was evaluated by receiver operating characteristic (ROC) curve and survival analysis, using the Kaplan-Meier method, which was performed with the data from a 5-year follow-up. The expression of miR-196b in the serum of patients with CRC was significantly higher compared with that in Ad patients or healthy individuals (all P<0.001), and the overexpression of serum miR-196b was clearly associated with lymph node invasion, differentiation, and the tumor-lymph nodes-metastasis stage (all P<0.05). ROC curve analysis demonstrated that, comparing patients with CRC with healthy individuals, the area under the curve of serum miR-196b was 0.8135, and its specificity and sensitivity were 63 and 87.38%, respectively, at a diagnostic threshold of −4.785. Patients with CRC of miR-196b-high status had shorter overall survival and disease-free survival rates compared with those of miR-196b-low status. In conclusion, the results of the present study demonstrated that serum miR-196b is upregulated in CRC, and may have an application as a diagnostic and prognostic biomarker for patients with CRC. PMID:28123705
Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong
2017-01-01
Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime, laboratorians must remain alert to the negative interference by rheumatoid factor, and in some cases, pretreat rheumatoid factor-positive samples with blocking or absorbing reagents.
Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing
2015-01-01
Objective Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Methods Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. Results A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. Conclusion A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC. PMID:26487969
Hernandez, Michelle; Zhou, Haibo; Zhou, Bingqing; Robinette, Carole; Crissman, Kay; Hatch, Gary; Alexis, Neil E; Peden, David
2011-01-01
Oxidative stress plays a significant role in allergic airway inflammation. Supplementation with alpha-tocopherol (alone or combined with ascorbate/vitamin C) has been assessed as an intervention for allergic airway diseases with conflicting results. Enhancing levels of airway antioxidants with oral supplements has been suggested as an intervention to protect individuals from the effect of inhaled oxidants, although it is unclear whether supplementation changes tocopherol or vitamin C levels in both serum and airway fluids. Our objective was to obtain pilot safety and dosing data from 14 allergic asthmatic volunteers examining the effect of daily combination oral therapy with 500 mg alpha-tocopherol (αT) and 2 g vitamin C for 12 wk. We examined serum and airway fluid and cellular levels of alpha- and gamma-tocopherol (γT) and vitamin C to plan for future studies of these agents in asthma and allergic rhinitis. Six volunteers completed 12 wk of active treatment with αT and vitamin C and 8 completed placebo. Blood and sputum samples were obtained at baseline and at 6 wk and 12 wk of therapy and were analyzed for αT, γT, and vitamin C levels in the serum, sputum supernatant, and sputum cells. Combination treatment increased serum vitamin C and significantly decreased sputum αT and serum γT levels. No changes were found in sputum supernatant or sputum cell vitamin C or serum αT levels in the active treatment group. In conclusion, supplementation with αT and high-dose vitamin C does not augment vitamin C levels in the respiratory-tract lining fluid. PMID:18932058
BK Virus Load Associated with Serum Levels of sCD30 in Renal Transplant Recipients
Malik, Salma N.; Al-Saffer, Jinan M.; Jawad, Rana S.
2016-01-01
Background. Rejection is the main drawback facing the renal transplant operations. Complicated and overlapping factors, mainly related to the immune system, are responsible for this rejection. Elevated serum levels of sCD30 were frequently recorded as an indicator for renal allograft rejection, while BV virus is considered as one of the most serious consequences for immunosuppressive treatment of renal transplant recipients (RTRs). Aims. This study aimed to determine the association of BK virus load with serum levels of sCD30 in RTRs suffering from nephropathy. Patients and Methods. A total of 50 RTRs with nephropathy and 30 age-matched apparently healthy individuals were recruited for this study. Serum samples were obtained from each participant. Real-time PCR was used to quantify BK virus load in RTRs serum, while ELISA technique was employed to estimate serum levels of sCD30. Results. Twenty-two percent of RTRs had detectable BKV with mean viral load of 1.094E + 06 ± 2.291E + 06. RTRs showed higher mean serum level of sCD30 (20.669 ± 18.713 U/mL) than that of controls (5.517 ± 5.304 U/mL) with significant difference. BK virus load had significant positive correlation with the serum levels of sCD30 in RTRs group. Conclusion. These results suggest that serum levels of sCD30 could be used as an indicator of BK viremia, and accordingly the immunosuppressive regime should be adjusted. PMID:27051424
Diagnosis of cysticercosis in endemic regions. The Cysticercosis Working Group in Peru.
Garcia, H H; Martinez, M; Gilman, R; Herrera, G; Tsang, V C; Pilcher, J B; Diaz, F; Verastegui, M; Gallo, C; Porras, M
1991-08-31
Taenia solium cysticercosis is a frequent cause of neurological disease in developing countries. Specific diagnosis of cysticercosis is difficult. We obtained serum and/or CSF samples from 204 consecutive patients admitted to a neurological ward in Lima, Peru, and looked for antibodies specific for T solium with the enzyme-linked immunoelectrotransfer blot (EITB) assay. 21 (12%) of 173 serum samples from these patients were EITB-positive. In contrast, only 2 (1.5%) of 135 patients attending a public endoscopy clinic and 1 (1%) of 88 patients attending a private endoscopy clinic were seropositive. 1 (1%) of 98 pregnant women living in a Lima shanty town was EITB-positive. 15 (58%) of 26 neurology patients diagnosed clinically as having cysticercosis were seronegative. Routine screening by EITB of all patients with neurological symptoms from areas of endemic cysticercosis would avoid misdiagnosis of this common and treatable disease.
Diagnosis of cysticercosis in endemic regions
Garcia, H. H.; Martinez, M.; Gilman, R.; Herrera, G.; Tsang, V. C. W.; Pilcher, J. B.; Diaz, F.; Verastegui, M.; Gallo, C.; Porras, M.; Alvarado, M.; Naranjo, J.; Miranda, E.
2010-01-01
Taenia solium cysticercosis is a frequent cause of neurological disease in developing countries. Specific diagnosis of cysticercosis is difficult. We obtained serum and/or CSF samples from 204 consecutive patients admitted to a neurological ward in Lima, Peru, and looked for antibodies specific for T solium with the enzyme-linked immunoelectrotransfer blot (EITB) assay. 21 (12%) of 173 serum samples from these patients were EITB-positive. In contrast only 2 (1·5%) of 135 patients attending a public endoscopy clinic and 1 (1%) of 88 patients attending a private endoscopy clinic were seropositive. 1 (1%) of 98 pregnant women living in a Lima shanty town was EITB-positive. 15 (58%) of 26 neurology patients diagnosed clinically as having cysticercosis were seronegative. Routine screening by EITB of all patients with neurological symptoms from areas of endemic cysticercosis would avoid misdiagnosis of this common and treatable disease. PMID:1678809
NASA Astrophysics Data System (ADS)
Chen, Yanhua; Gao, Dejiang; Tian, Yuan; Ai, Peng; Zhang, Hanqi; Yu, Aimin
2007-07-01
As a resonance light scattering (RLS) probe, the polyelectrolyte polymethacrylic acid (PMAA) was applied in this assay. The bovine serum albumin (BSA) and human serum albumin (HSA) were determined by the electrostatic interaction of PMAA and proteins. At pH 3.8 Na 2HPO 4-citric acid buffer solution, the RLS intensities of PMAA-BSA (HSA) system were greatly enhanced. The characteristic peaks were appeared at the wavelength 320, 546 and 594 nm. The optimization conditions of the reaction were also examined and selected. Under the selected conditions, the RLS intensities were proportional to the protein concentrations in the range of (0.0200-2.00) × 10 -6 mol/L for BSA and (0.0200-2.40) × 10 -6 mol/L for HSA. The influences of some foreign substances were also examined. The synthetic samples containing proteins and some real samples were analyzed and the results obtained were satisfactory.
Chen, Yanhua; Gao, Dejiang; Tian, Yuan; Ai, Peng; Zhang, Hanqi; Yu, Aimin
2007-07-01
As a resonance light scattering (RLS) probe, the polyelectrolyte polymethacrylic acid (PMAA) was applied in this assay. The bovine serum albumin (BSA) and human serum albumin (HSA) were determined by the electrostatic interaction of PMAA and proteins. At pH 3.8 Na(2)HPO(4)-citric acid buffer solution, the RLS intensities of PMAA-BSA (HSA) system were greatly enhanced. The characteristic peaks were appeared at the wavelength 320, 546 and 594 nm. The optimization conditions of the reaction were also examined and selected. Under the selected conditions, the RLS intensities were proportional to the protein concentrations in the range of (0.0200-2.00) x 10(-6) mol/L for BSA and (0.0200-2.40) x 10(-6) mol/L for HSA. The influences of some foreign substances were also examined. The synthetic samples containing proteins and some real samples were analyzed and the results obtained were satisfactory.
Lack of correlation between serum soluble Fas/APO-1 levels and autoimmune disease.
Goel, N; Ulrich, D T; St Clair, E W; Fleming, J A; Lynch, D H; Seldin, M F
1995-12-01
To determine whether elevated soluble Fas/APO-1 (sFas/APO-1) levels are associated with either autoimmune disease or evidence of flares in autoimmune disease. Thirty-seven serum samples were retrospectively obtained from normal controls and patients with laboratory evidence of autoimmune disease activity. These samples were assayed for sFas/APO-1 levels by an enzyme-linked immunosorbent assay, and hospital medical records were retrospectively reviewed for clinical and laboratory characteristics of the patients. Soluble Fas/APO-1 levels did not correlate with clinical diagnoses or laboratory abnormalities. The mean and range of sFas/APO-1 levels were similar in systemic lupus erythematosus patients (including those with active disease), patients with other autoimmune diseases, and normal controls. These data strongly suggest that measurement of sFas/APO-1 levels is unlikely to hold clinical value or play a role in the pathogenesis of autoimmune disease.
Healthcare Worker Seroconversion in SARS Outbreak
Ooi, Eng-Eong; Tan, Hiang-Khoon; Ong, Kong-Wee; Sil, Bijon Kumar; Teo, Melissa; Ng, Timothy; Soo, Khee-Chee
2004-01-01
Serum samples were obtained from healthcare workers 5 weeks after exposure to an outbreak of severe acute respiratory syndrome (SARS). A sensitive dot blot enzyme-linked immunosorbent assay, complemented by a specific neutralization test, shows that only persons in whom probable SARS was diagnosed had specific antibodies and suggests that subclinical SARS is not an important feature of the disease. PMID:15030691
Ozkan, Seda; Ikizceli, Ibrahim; Sözüer, Erdoğan Mütevelli; Avşaroğullari, Levent; Oztürk, Figen; Muhtaroğlu, Sebahattin; Akdur, Okhan; Küçük, Can; Durukan, Polat
2008-10-01
To demonstrate the effect of piracetam on changes in brain tissue and serum nitric oxide levels in dogs submitted to hemorrhagic shock. The subjects were randomized into four subgroups each consisting of 10 dogs. Hemorrhagic shock was induced in Group I for 1 hour and no treatment was given to this group. Blood and saline solutions were administered to Group II following 1 hour hemorrhagic shock. Blood and piracetam were given to Group III following 1 hour shock. No shock was induced and no treatment was applied to Group IV. Blood samples were obtained at the onset of the experiment and at 60, 120 and 180 minutes for nitric oxide analysis. For histopathological examination, brain tissue samples were obtained at the end of the experiment. The observed improvement in blood pressure and pulse rates in Group III was more than in Group II. Nitric oxide levels were increased in Group I; however, no correlation between piracetam and nitric oxide levels was determined. It was seen that recovery in brain damage in Group III was greater than in the control group. Piracetam, added to the treatment, may ecrease ischemic damage in hemorrhagic shock.
Zhang, Shuo; Zhao, Yunfeng; Li, Haijiao; Zhou, Shuang; Chen, Dawei; Zhang, Yizhe; Yao, Qunmei; Sun, Chengye
2016-01-01
Amatoxins and phallotoxins are toxic cyclopeptides found in the genus Amanita and are among the predominant causes of fatal food poisoning in China. In the treatment of Amanita mushroom poisoning, an early and definite diagnosis is necessary for a successful outcome, which has prompted the development of protocols for the fast and confirmatory determination of amatoxins and phallotoxins in human biological fluids. For this purpose, a simple, rapid and sensitive multiresidue UPLC-MS/MS method for the simultaneous determination of α-amanitin, β-amanitin, γ-amanitin, phalloidin (PHD) and phallacidin (PCD) in human plasma, serum and urine was developed and validated. The diluted plasma, serum and urine samples were directly purified with a novel PRiME technique on a 96-well μElution plate platform, which allowed high-throughput sample processing and low reagent consumption. After purification, a UPLC-MS/MS analysis was performed using positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode. This method fulfilled the requirements of a validation test, with good results for the limit of detection (LOD), lower limit of quantification (LLOQ), accuracy, intra- and inter-assay precision, recovery and matrix effects. All of the analytes were confirmed and quantified in authentic plasma, serum and urine samples obtained from cases of poisoning using this method. Using the PRiME μElution technique for quantification reduces labor and time costs and represents a suitable method for routine toxicological and clinical emergency analysis. PMID:27153089
Sureda-Vives, Macià; Morell-Garcia, Daniel; Rubio-Alaejos, Ana; Valiña, Laura; Robles, Juan; Bauça, Josep Miquel
2017-09-01
Osmolality reflects the concentration of all dissolved particles in a body fluid, and its measurement is routinely performed in clinical laboratories for the differential diagnosis of disorders related with the hydrolytic balance regulation, the renal function and in small-molecule poisonings. The aim of the study was to assess the stability of serum, plasma and urine osmolality through time and under different common storage conditions, including delayed centrifugation. Blood and urine samples were collected, and classified into different groups according to several preanalytical variables: serum or plasma lithium-heparin tubes; spun or unspun; stored at room temperature (RT), at 4°C or frozen at -21°C. Aliquots from each group were assayed over time, for up to 14days. Statistical differences were based on three different international performance criteria. Whole blood stability was higher in the presence of anticoagulant. Serum osmolality was stable for 2days at RT and 8days at 4°C, while plasma was less stable when refrigerated. Urine stability was 5days at RT, 4days at 4°C and >14days when frozen. Osmolality may be of great interest for the management of several conditions, such as in case of a delay in the clinical suspicion, or in case of problems in sample collection or processing. The ability to obtain reliable results for samples kept up to 14days also offers the possibility to retrospectively assess baseline values for patients which may require it. Copyright © 2017. Published by Elsevier Inc.
Ameri, Mehrdad; Schnaars, Henry; Sibley, John; Honor, David
2011-01-01
The most widely used method for bilirubin concentration determination is the diazo method, which measures the color of azobilirubin. The vanadate oxidase method is based on oxidation of bilirubin to biliverdin by vanadate. The objective of this study was to compare total and direct bilirubin concentration ([Bt] and [Bd], respectively) determined by the diazo and vanadate oxidase methods in pooled serum samples from dogs, monkeys, and rats spiked with panels of different concentrations of bilirubin standards. Pooled serum samples from 40 dogs, 40 monkeys, and 60 rats were spiked with either ditaurine conjugates of bilirubin or a standard reference material. The results obtained from both assays were compared using Deming regression analysis. The intra- and interassay precision, expressed as a percentage of the coefficient of variation (%CV), was determined for [Bt] and [Bd], and the mean percentage of recovery was calculated. The vanadate oxidase method displayed an excellent correlation (r = 0.99-1.00) with the diazo method. Using Deming regression, there were minimal negative or positive constant and proportional biases for [Bt] and [Bd]. The precision studies revealed that the vanadate oxidase method has comparable between-run and within-run CVs to those of the diazo method. The recovery study demonstrated that the diazo method more closely approximates the expected values of [Bt]. In conclusion, the vanadate oxidase method is a simple and rapid method that can be employed as an alternative to the diazo method when interfering substances are present in the serum samples of dog, monkey, and rat.
Antioxidant capacity and oxygen radical diseases in the preterm newborn.
Rogers, S; Witz, G; Anwar, M; Hiatt, M; Hegyi, T
2000-06-01
Bronchopulmonary dysplasia, intraventricular hemorrhage, necrotizing enterocolitis, and retinopathy of prematurity may be different manifestations of oxygen radical diseases of prematurity (ORDP). To test the hypothesis that the antioxidant capacity of cord blood serum will predict risk of ORDP. An inception cohort of premature neonates was followed up from birth until discharge or death to determine if outcome was related to cord blood serum antioxidant capacity, as determined by a manual assay measuring the relative inhibition of oxidation of 2,2'-azino-di-(3-ethylbenzthiazoline)-6 sulfonic acid (ABTS). Possible correlations between antioxidant capacity and various perinatal factors were also tested. Level 3 newborn intensive care unit. All inborn very low-birth-weight neonates from whom cord blood was available and for whom maternal consent was obtained were included. Newborns who died in the first week of life or who had major congenital malformations were excluded. A convenience sample of newborns weighing more than 1500 g was used to perfect assay and explore confounders. Significant ORDP was defined as the presence of intraventricular hemorrhage greater than grade 2, retinopathy of prematurity greater than stage 1, bronchopulmonary dysplasia at the postconceptional age of 36 weeks, or necrotizing enterocolitis with the hypothesis that neonates with ORDP will have lower antioxidant capacity in cord blood serum. Serum antioxidant capacity at birth correlated with gestational age for the entire sample of 41 neonates and for the 26 neonates born before 32 weeks' gestation. After correction for gestational age, cord serum antioxidant capacity did not correlate with maternal smoking, preeclampsia, chorioamnionitis, cord pH Apgar scores, or any of the ORDP studied. Cord serum antioxidant capacity correlates with gestational age but does not predict ORDP risk.
O'Rourke, Dennis J; DiJohnson, Daniel A; Caiazzo, Robert J; Nelson, James C; Ure, David; O'Leary, Michael P; Richie, Jerome P; Liu, Brian C-S
2012-03-22
Serum prostate specific antigen (PSA) concentrations lack the specificity to differentiate prostate cancer from benign prostate hyperplasia (BPH), resulting in unnecessary biopsies. We identified 5 autoantibody signatures to specific cancer targets which might be able to differentiate prostate cancer from BPH in patients with increased serum PSA. To identify autoantibody signatures as biomarkers, a native antigen reverse capture microarray platform was used. Briefly, well-characterized monoclonal antibodies were arrayed onto nanoparticle slides to capture native antigens from prostate cancer cells. Prostate cancer patient serum samples (n=41) and BPH patient samples (collected starting at the time of initial diagnosis) with a mean follow-up of 6.56 y without the diagnosis of cancer (n=39) were obtained. One hundred micrograms of IgGs were purified and labeled with a Cy3 dye and incubated on the arrays. The arrays were scanned for fluorescence and the intensity was quantified. Receiver operating characteristic curves were produced and the area under the curve (AUC) was determined. Using our microarray platform, we identified autoantibody signatures capable of distinguishing between prostate cancer and BPH. The top 5 autoantibody signatures were TARDBP, TLN1, PARK7, LEDGF/PSIP1, and CALD1. Combining these signatures resulted in an AUC of 0.95 (sensitivity of 95% at 80% specificity) compared to AUC of 0.5 for serum concentration PSA (sensitivity of 12.2% at 80% specificity). Our preliminary results showed that we were able to identify specific autoantibody signatures that can differentiate prostate cancer from BPH, and may result in the reduction of unnecessary biopsies in patients with increased serum PSA. Copyright © 2011 Elsevier B.V. All rights reserved.
False positive acetaminophen concentrations in patients with liver injury.
Polson, Julie; Wians, Frank H; Orsulak, Paul; Fuller, Dwain; Murray, Natalie G; Koff, Jonathan M; Khan, Adil I; Balko, Jody A; Hynan, Linda S; Lee, William M
2008-05-01
Acetaminophen toxicity is the most common form of acute liver failure in the U.S. After acetaminophen overdoses, quantitation of plasma acetaminophen can aid in predicting severity of injury. However, recent case reports have suggested that acetaminophen concentrations may be falsely increased in the presence of hyperbilirubinemia. We tested sera obtained from 43 patients with acute liver failure, mostly unrelated to acetaminophen, utilizing 6 different acetaminophen quantitation systems to determine the significance of this effect. In 36 of the 43 samples with bilirubin concentrations ranging from 1.0-61.5 mg/dl no acetaminophen was detectable by gas chromatography-mass spectroscopy. These 36 samples were then utilized to test the performance characteristics of 2 immunoassay and 4 enzymatic-colorimetric methods. Three of four colorimetric methods demonstrated 'detectable' values for acetaminophen in from 4 to 27 of the 36 negative samples, low concentration positive values being observed when serum bilirubin concentrations exceeded 10 mg/dl. By contrast, the 2 immunoassay methods (EMIT, FPIA) were virtually unaffected. The false positive values obtained were, in general, proportional to the quantity of bilirubin in the sample. However, prepared samples of normal human serum with added bilirubin showed a dose-response curve for only one of the 4 colorimetric assays. False positive acetaminophen tests may result when enzymatic-colorimetric assays are used, most commonly with bilirubin concentrations >10 mg/dl, leading to potential clinical errors in this setting. Bilirubin (or possibly other substances in acute liver failure sera) appears to affect the reliable measurement of acetaminophen, particularly with enzymatic-colorimetric assays.
Wollanke, B; Gerhards, H; Brem, S; Kopp, H; Meyer, P
1998-04-01
Between February 1993 and July 1997, 150 horses suffering from recurrent uveitis were subjected to parsplana vitrectomy. In these horses, antibody titers to Leptospira serovars were determined in serum samples and in samples from diluted vitreous collected during vitrectomy. Although the vitreous samples were diluted with 250 ml of balanced salt solution, in 86 of the 150 vitreous samples (= 57%) the antibody titers were higher than in the serum samples. Additionally, serum samples from 77 horses suffering from ERU, but which were not subjected to vitrectomy, and serum samples from 97 horses with clinically normal eyes were analyzed for antibodies to Leptospira serovars. Among the 227 horses with ERU (150 treated surgically, 77 treated conservatively) 50 horses (50 of 227 = 22%) had serum antibody titers to Leptospira serovars of > or = 1:800. Among the 97 horses with clinically normal eyes, 24 horses (24 of 97 = 25%) had serum antibody titers to Leptospira serovars of > or = 1:800. In undiluted vitreous samples from 20 horses with clinically normal eyes, no antibody titers to Leptospira serovars could be detected. Among the 150 horses with ERU, 90 animals (90 of 150 = 60%) had antibody titers of > or = 1:100 in the diluted vitreous samples, the difference being highly significant (p < 0.001). The findings are discussed in relation to the etiology of recurrent uveitis in horses.
Ilesanmi, A O; Adeleye, J A; Osotimehin, B O
1995-03-01
Infertility remains a medico-social problem in Nigeria and it accounts for a large percentage of outpatient gynecological consultations. The evaluation of the infertile couple remains a continuing challenge to the practising doctor in this part of the world. The need to evaluate the two methods commonly used for determining ovulation in these patients is indicated. Endometrial biopsy specimen and a single sample for serum progesterone estimation were obtained simultaneously in the luteal phase from 50 normally menstruating infertile Nigerian women. Subsequent analysis showed that a serum progesterone value of 6.6 nmol/l (2.2 ng/ml) or above was always associated with a secretory endometrium. Forty-six cycles yielded sufficient information to compare the two methods for confirmation of ovulation. Patients who ovulated with a progesterone value of 6.6 nmol/l (2.2 ng/ml) were 91.3% (42/46) or above, while 89% (41/46) showed secretory endometrium. Forty-six of the cases 86.9% (40/46) were judged to have ovulated by both parameters while 6.5% demonstrated anovulatory cycle using both criteria. From the study, a significant correlation was obtained between endometrial biopsy and progesterone assay methods in confirming ovulation.
Simple, miniaturized blood plasma extraction method.
Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E
2013-12-03
A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to that observed with serum samples obtained by venipuncture.
Torres, J R; Mondolfi, A
1991-01-01
In an investigation of a 21-year-old epidemic of severe hepatitis, 80 serum samples were studied from two isolated Yanomami Amerindian populations of the Upper Orinoco basin in Venezuela. Of the assayed samples, 30.6% were positive for hepatitis B surface antigen (HBsAg), 53.7% were considered to reflect immunity to infection with hepatitis B virus (HBV), and only 16.2% were believed to reflect susceptibility to HBV infection; 82.5% of the samples tested positive for any marker of HBV infection. Thirty-one (39.7%) of 78 samples were also positive for antibody to delta antigen, including 91.6% of those positive for HBsAg and 20.9% of those immune to HBV. Our findings provide evidence of a high prevalence of HBV infection in this population. Furthermore, the high prevalence of antibody to delta antigen strongly suggests that coinfections with HBV or superinfections with hepatitis delta virus (HDV) in HBV carriers may be an important factor in the occurrence of an unusually high number of cases of fulminant hepatitis and of chronic liver disease. Serum samples obtained at the beginning of the outbreak 13 years earlier from 36 selected cases in the same population revealed a high rate of HBV infection (96.5%). All six HBsAg carriers from whom enough serum remained to be assayed were positive for antibody to delta antigen. Our findings indicate that the outbreak coincided with the introduction of HDV into a population with an already-high prevalence of HBV infection.
Wang, Jiaojiao; Lan, Jingfeng; Li, Huihui; Liu, Xiaoyan; Zhang, Haixia
2017-01-01
In proteomic studies, poor detection of low abundant proteins is a major problem due to the presence of highly abundant proteins. Therefore, the specific removal or depletion of highly abundant proteins prior to analysis is necessary. In response to this problem, a series of pH-sensitive functional mesoporous silica materials composed of 2-(diethylamino)ethyl methacrylate and methacrylic acid units were designed and synthesized via atom transfer radical polymerization. These functional mesoporous silica materials were characterized and their ability for adsorption and separation of proteins was evaluated. Possessing a pH-sensitive feature, the synthesized functional materials showed selective adsorption of some proteins in aqueous or buffer solutions at certain pH values. The specific removal of a particular protein from a mixed protein solution was subsequently studied. The analytical results confirmed that all the target proteins (bovine serum albumin, ovalbumin, and lysozyme) can be removed by the proposed materials from a five-protein mixture in a single operation. Finally, the practical application of this approach was also evaluated by the selective removal of certain proteins from real biological samples. The results revealed that the maximum removal efficiencies of ovalbumin and lysozyme from egg white sample were obtained as 99% and 92%, respectively, while the maximum removal efficiency of human serum albumin from human serum sample was about 80% by the proposed method. It suggested that this treatment process reduced the complexity of real biological samples and facilitated the identification of hidden proteins in chromatograms. Copyright © 2016 Elsevier B.V. All rights reserved.
Serological Detection of Viral Infections in Captive Wild Cats from Costa Rica
Blanco, Kinndle; Peña, Roberto; Hernández, Carmen; Jiménez, Mauricio; Araya, Luis Nazario; Romero, Juan José; Dolz, Gaby
2011-01-01
Serum samples from a total of 44 wildcats, 28 margays (Leopardus wiedii), 10 ocelots (Leopardus pardalis), four jaguaroundis (Herpailurus yaguaroundi), one oncilla (Leopardus tigrina), and one jaguar (Panthera onca) were obtained between January 2001 and August 2002 from the Profelis Centre for rehabilitation of wild felids, located in the northwestern region of Costa Rica. Forty three samples were tested for antibodies against feline immunodeficiency virus (FIV) and p27 antigen of feline leukemia virus (FeLV), 42 samples for antibodies against feline parvovirus (FPV), and 30 for antibodies against feline calicivirus (FCV). None of the samples contained detectable antibodies against FIV or p27 antigen of FeLV, all samples contained antibodies against FPV, and one sample contained antibodies against FCV. PMID:21547230
Serological detection of viral infections in captive wild cats from costa rica.
Blanco, Kinndle; Peña, Roberto; Hernández, Carmen; Jiménez, Mauricio; Araya, Luis Nazario; Romero, Juan José; Dolz, Gaby
2011-04-03
Serum samples from a total of 44 wildcats, 28 margays (Leopardus wiedii), 10 ocelots (Leopardus pardalis), four jaguaroundis (Herpailurus yaguaroundi), one oncilla (Leopardus tigrina), and one jaguar (Panthera onca) were obtained between January 2001 and August 2002 from the Profelis Centre for rehabilitation of wild felids, located in the northwestern region of Costa Rica. Forty three samples were tested for antibodies against feline immunodeficiency virus (FIV) and p27 antigen of feline leukemia virus (FeLV), 42 samples for antibodies against feline parvovirus (FPV), and 30 for antibodies against feline calicivirus (FCV). None of the samples contained detectable antibodies against FIV or p27 antigen of FeLV, all samples contained antibodies against FPV, and one sample contained antibodies against FCV.
[False positive serum des-gamma-carboxy prothrombin after resection of hepatocellular carcinoma].
Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi
2007-04-01
Measurements of serum concentrations of des-gamma-carboxy-prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, when we evaluated the correlation of PIVKA-II between two commercially available PIVKA-II immunoassay kits (Lumipulse f vs. Picolumi) to introduce it in our hospital, false high values of PIVKA-II were observed in Lumipulse assay. Four(4%) of 100 serum samples showed false high values, and all of them were obtained from patients less than 2 month after curative resection of HCC. Examining additional 7 patients with HCC resection, serum samples from the 5 patients had the same trend. To elucidate the non-specific reaction by Lumipulse assay which utilized alkaline phosphatase (ALP) enzymatic reaction, inhibition assays by various absorbents such as inactive ALP and IgM antibodies were performed. Excess of inactive ALP reduced the high values of PIVKA-II. Note that anti-bleeding sheets (fibrinogen combined drug), which included bovine thrombin, were directly attached on liver of all patients with HCC resection in this study. As the sheets also contaminate ALP and probably produce IgM antibodies to ALP, the IgM may cross-react with anti-PIVKA-II antibodies directly. Taken together, it was suggested that produced antibodies against ALP derived from anti-bleeding sheets led false high values of PIVKA-II in the patients with HCC resection.
Yu, Ting; Gao, Shangxian; Yin, Aihua; Tang, Yongping; Wu, Yingsong; Li, Lili; Li, Ming
2013-01-01
Pregnancy-associated plasma protein A (PAPP-A) is an important serum marker for first trimester screening. Its weekly median value varies with ethnicity. A one-step time-resolved fluoroimmunoassay (TRFIA) using two monoclonal antibodies against PAPP-A with Eu(3+) chelates as labels has been developed. Using the assay described here, we evaluated 5,301 normal serum samples from Chinese women at 7-13 weeks of gestation. The detection limit using this assay was 1.2 mIU/L, and the maximum detection range was up to 10,000 mIU/L. The intra-assay and inter-assay coefficients of variation were <3.0% and <5.0%, respectively, and the mean recovery rate was 98.0%. PAPP-A concentrations measured in 516 maternal serum samples correlated well with those obtained by Dissociation-Enhanced Lanthanide Fluorescent Immunoassay (DELFIA) PAPP-A assay (r=0.988, P<0.001). The medians for 7-13 weeks of maternal serum PAPP-A were higher in the women from China compared to reports from other countries. The present assay possesses accuracy and high sensitivity and exhibits great potential for the clinical analysis of PAPP-A. Our investigation on the median concentrations of PAPP-A will help establish reference values that are specific for China and study the importance of ethnic factors in biochemical screening.
Relationship of glomerular filtration rate and serum CK activity after resistance exercise in women.
Machado, Marco; Zini, Elida N; Valadão, Samara D; Amorim, Mayra Z; Barroso, Tiago Z; de Oliveira, Wilkes
2012-04-01
The aim of study was to assess the correlation between the changes in serum CK activity after a resistance exercise and renal function measured by glomerular filtration rate (eGFR). Twenty-nine trained women (32 ± 10 years; 157 ± 4 cm; 58.8 ± 6.4 kg) performed a resistance exercise session with 17 exercises with 3 × 12 repetitions in a circuit training fashion. Subjects provided blood samples prior to exercise session (PRE), and at 24, 48, and 72 h following exercise session for creatine kinase (CK) and creatinine. 24-Urine samples were collected before and 72 h after exercises. eGFR was obtained by the three most recommended methods (MDRD; MCQE; Cockcroft-Gault). After the exercise session, serum CK activity increase up 1.68 times (P < 0.01). Serum creatinine increased 25.5% (P = 0.0000) while urinary creatinine decreased on average 6.4% (P = 0.0422). eGFR decreased in all formulas: MDRD by 21.5%, MCQE by 14.2%, and C-G by 17% (all with P < 0.01). Ccr also decreased (-22.9%, P < 0.01). The index of correlation was significant for MDRD (r = -0.924; P < 0.01), C-G (r = -0.884; P < 0.01), and MQCE (r = -0.644; P < 0.05). In conclusion, we observed a significant negative correlation between CK activity and the eGFR indices of renal function.
Kaya, Safak; Elaldi, Nazif; Kubar, Ayhan; Gursoy, Nevcihan; Yilmaz, Meral; Karakus, Gulderen; Gunes, Turabi; Polat, Zubeyde; Gozel, Mustafa Gokhan; Engin, Aynur; Dokmetas, Ilyas; Bakir, Mehmet; Yilmaz, Neziha; Sencan, Mehmet
2014-07-28
Although there have been a number of studies on the pathogenesis of Crimean-Congo hemorrhagic fever (CCHF) recently, knowledge on this topic is still insufficient. This study aims to reveal the kinetics of serum CCHF virus (CCHFV) titers, serum levels of anti-CCHFV immunoglobulin (Ig)G, tumor necrosis factor (TNF)-α, interleukin (IL)-6, IL-10, and interferon (IFN)-γ in CCHF patients. In total, 31 CCHF cases (11 fatal) were studied. Serum samples were obtained daily from all patients from the time of admission and continued for a 7-day hospitalization period for serologic (ELISA), virologic (real-time PCR), and cytokine (ELISA) analysis. The mean serum CCHFV titer at admission was 5.5E + 09 copies/mL in fatal cases and 5.7E + 08 copies/mL in survivors (p < 0.001). Compared to survivors, both the mean serum levels of IL-6 and TNF-α at admission were found to be significantly increased in fatal cases. The serum levels of IL-6, TNF-α and serum CCHFV titer at admission were significantly and positively correlated with disseminated intravascular coagulation (DIC) scores (r = 0.626, p = 0.0002; r = 0.461, p = 0.009; and r = 0.625, p = 0.003, respectively). When the data obtained from the sequential determination of CCHFV titer and levels of anti-CCHFV IgG, IL-6, TNF-α, IL-10 and IFN-γ were grouped according to the days of illness, the initial serum CCHFV titer of a fatal patient was 5.5E + 09 (copies/mL) and it was 6.1E + 09 (copies/mL) in a survivor on the 2 day of illness. While significant alterations were observed in all cytokines during the monitoring period, IL-6 levels remained consistently higher in fatal cases and TNF-α levels increased in both in fatal and non-fatal CCHF cases. The increased CCHFV load and higher concentrations of IL-6 and TNF-α, the presence of DIC, and the absence of CCHFV specific immunity are strongly associated with death in CCHF.
An evaluation of the histological effects of intra-articular methadone in the canine model.
Jones, Timothy A; Hand, Walter R; Ports, Michael D; Unger, Daniel V; Herbert, Daniel; Pellegrini, Joseph E
2003-02-01
Methadone hydrochloride is an opiate that has pharmacodynamic and pharmacokinetic properties that suggest it may provide longer analgesia than morphine when administered via the intra-articular route. However, no studies to date have been conducted examining the effects of intra-articular methadone hydrochloride on local tissues. Therefore, the purpose of this study was to determine the histopathologic effects of intra-articular methadone hydrochloride on local tissues in the canine knee. Nine canines, 1 to 4 years old, weighing between 20 kg and 23 kg were used. All canines had their knees randomized to receive either bupivacaine, 0.5% with epinephrine 1:200,000 (4.5 mL), and 5 mg methadone hydrochloride (0.5 mL) for the study knee, or bupivacaine, 0.5% with epinephrine 1:200,000 (4.5 mL), and 0.5 mL normal saline for the control knee. Serum methadone hydrochloride levels were obtained on all canines at 6 and 24 hours. Canines were randomly assigned to 1 of 3 groups to be euthanized at either 24 hours, 14 days, or 28 days. Following euthanization and necropsy, synovial fluid levels and tissue samples were obtained and examined for histopathologic changes. Synovial fluid samples noted a few white blood cells at 24 hours and none at 14 and 28 days. Tissue samples showed no histopathologic changes, and serum concentration levels of methadone hydrochloride were negligible.
Kidney cell electrophoresis, continuing task
NASA Technical Reports Server (NTRS)
Todd, P. W.
1985-01-01
Materials and procedures for microgravity electrophoresis of living human embryonic kidney cells were evaluated to provide ground support in the form of analytical cell electrophoresis and flow cytometry. Preflight culture media, electrophoresis buffer, fraction collection media, temperature profiles, and urokinase assay procedures were tested prior to flight. Electrophoretic mobility distributions of aliquots of the cell population to be fractionated in flight were obtained. Cells were prepared in suspension prior to flight in electrophoresis buffer and 10% calf serum. Electrophoretic separation proceeded in electrophoresis buffer without serum in the Continuous Flow Electrophoretic Separator, and fractions were collected into sample bags containing culture medium and concentrated serum. Fractions that yielded enough progeny cells were analyzed for morphology and electrophoretic mobility distributions. It is noted that the lowest mobility fraction studied produced higher mobility progeny while the other fractions produced progeny cells with mobilities related to the fractions from which they were collected.
High-Resolution Metabolomics for Nutrition and Health Assessment of Armed Forces Personnel.
Accardi, Carolyn Jonas; Walker, Douglas I; Uppal, Karan; Quyyumi, Arshed A; Rohrbeck, Patricia; Pennell, Kurt D; Mallon, Col Timothy M; Jones, Dean P
2016-08-01
The aim of this study was to test the utility of high-resolution metabolomics (HRM) for analysis of nutritional status and health indicators in military personnel. Serum samples from 400 military personnel were obtained from the Department of Defense Serum Repository (DoDSR) and analyzed for metabolites related to nutrition and health status. Metabolic profile organization was studied using modulated modularity clustering (MMC). HRM provided quantitative measures of 61 metabolites across chemical classes for use as nutritional and clinical biomarkers. Levels were comparable to reported values except for arginine and glutamine, which were above and below reference ranges, respectively. MMC generated five clusters, three of which were associated and contained amino acids. The others contained lipids and mitochondria-related metabolites. HRM analysis of serum is suitable for real-time and/or retrospective evaluation of nutrition and health status of specific military cohorts.
Eating a healthy lunch improves serum alanine aminotransferase activity.
Iwamoto, Masako; Yagi, Kaori; Yazumi, Kayoko; Komine, Airi; Shirouchi, Bungo; Sato, Masao
2013-09-14
Nutritional guidance and diet control play important roles in the treatment of obesity and non-alcoholic fatty liver. However, in Japan, nutritional guidance is difficult to provide in practice. Therefore, we evaluated the effects of providing the 'once-a-day' intervention of a healthy lunch on various metabolic parameters. For a 1-month preparatory period, 10 subjects generally consumed the lunches that were provided by the worksite cafeteria. This was followed by a 1-week washout period, after which, the subjects consumed healthy, low-calorie, well-balanced lunches for a 1-month test period. After the preparatory and test periods, blood samples were obtained from all subjects. The serum levels of indices relevant to metabolic syndrome and fatty liver were measured. Serum alanine aminotransferase activity significantly decreased by 20.3% after the healthy intervention. However, the indices of metabolic syndrome did not significantly change. Analysis of the relationship between serum alanine aminotransferase activity and nutrient content indicated that the improvement of serum alanine aminotransferase status was due to the higher vegetable content and lower animal-source protein of the meals provided. In summary, the 'once-a-day' intervention of providing a healthy lunch improved serum alanine aminotransferase status. A diet high in vegetables and low in animal-based protein is important in maintaining a healthy condition.
Lawal, A O; Kolude, B; Adeyemi, B F; Lawoyin, J O; Akang, E E
2012-01-01
Tobacco and alcohol are major risk factors of oral cancer, but nutritional deficiency may also contribute to development of oral cancer. This study compared serum antioxidant vitamin levels in oral cancer patients and controls in order to validate the role of vitamin deficiencies in the etiology of oral cancer. Serum vitamin A, C, and E levels of 33 oral cancer patients and 30 controls at University College Hospital, Ibadan, Nigeria, were determined using standard methods. The data obtained were analyzed using the Student t-test, odds ratio, and logistic regression. Mean vitamin A, C, and E levels were significantly lower in oral cancer patients (P=0.022, P=0.000, and P=0.013 respectively). Risk of oral cancer was 10.89, 11.35, and 5.6 times more in patients with low serum vitamins A, C, and E, respectively. However, on logistic regression analysis, only low serum vitamin E independently predicted occurrence of oral cancer. The lower serum vitamin A, C, and E levels in oral cancer patients could be either a cause or an effect of the oral cancer. Further studies using a larger sample size and cohort studies with long-term follow-up of subjects are desirable.
Tande, Desiree L; Hotchkiss, Larry; Cotugna, Nancy
2004-04-01
Dietary recommendations are based on nutrients, foods, and food groups, but the relationship between the Food Guide Pyramid (FGP) food groups and serum lipids has not been studied. NHANES III data were obtained for US adults who met the following criteria: aged 20-59 years, reliable participant, and typical 24-h recall. We examined whether serum lipids (serum total cholesterol (STC), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), and triacylglycerol) were related to FGP food group intake (dairy, fruit, grain, meat, and vegetable). A sample of 9111 participants qualified for this analysis. Fruit intakes were inversely related to STC, HDL-C, and LDL-C (P = 0.012, P = 0.001, and P = 0.014, respectively) and directly related to triacylglycerol levels (P = 0.003). Grain intake was inversely associated with both STC and HDL-C (P = 0.020 and P = 0.000). Dairy and meat intakes were directly related to LDL-C (P = 0.026 and P = 0.020). Food groups are related to serum lipids. Universal definitions for food groups are needed in research and nutrition education. Studying the relationships between food groups and serum lipids is important for future dietary recommendations related to serum lipids.
Elevated EGF Levels in the Blood Serum of Dogs with Periodontal Diseases and Oral Tumours.
Sobczyńska-Rak, Aleksandra; Żylińska, Beata; Polkowska, Izabela; Szponder, Tomasz
2018-01-01
Paradontopathy and neoplasms of the oral cavity represent one of the greatest challenges in human and animal dentistry. EGF plays a key role in maintaining the integrity and proper rate of cell proliferation in normal oral epithelium. The aim of the present study was to study serum levels of EGF in dogs diagnosed with periodontal diseases and oral cavity tumours. The samples comprised of cancerous tissue sections and serum obtained from dogs of various breeds, aged between 5-13 years. Serum EGF concentrations were measured by an immunoenzymatic method. The median for EGF concentration in serum of dogs suffered from severe periodontal diseases was greater when compared to the control group. EGF concentration in dogs with malignant tumours was significantly higher than in those with non-malignant growths. A positive correlation between EGF concentration and tumour size was also observed. EGF level in dogs diagnosed with benign tumours was comparable to the control group. The blood serum level of EGF increases significantly in patients with malignant oral tumours and advanced periodontal disease. In malignant tumours, the high level of EGF correlates with the size and invasiveness of the neoplasm. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Spriggs, Maria C; Gerhold, Richard W; Wilkes, Rebecca P; Keenlance, Paul; Sanders, Robert L; Witt, Jill; Clark, Eric; Miller, Debra
2018-06-01
To better understand the clinical pathology, diseases, and causes of mortality of reintroduced American martens ( Martes americana) in Michigan, a study was conducted from 2011 to 2015 in the Upper and Lower Peninsulas of Michigan. Samples obtained from live trapping ( n = 58) or harvested carcasses ( n = 34) were serologically tested for select pathogens. Antibodies against Toxoplasma gondii and canine distemper virus were detected in 58 and 3.4% of samples, respectively. All samples were seronegative for Leptospira spp. and negative for Dirofilaria immitis antigen. Urine samples tested for Leptospira spp. via immunofluorescent antibody assay ( n = 7), polymerase chain reaction ( n = 6) , or both ( n = 3) were all negative. Parvovirus DNA was detected in 9.1% of small intestine samples ( n = 22) collected from carcasses and in 3.7% of fecal samples ( n = 27) collected during live trapping. Complete blood counts ( n = 64) and serum biochemistries ( n = 63) were obtained from 49 live-trapped martens. Biochemical parameters found to be significantly different ( P < 0.05) between genders were calcium, creatinine, glucose, and phosphorus. There was no significant difference between genders for any hematologic parameter. Significant differences ( P < 0.05) between summer and winter seasons were found in total estimated white blood cell count, neutrophils, lymphocytes, monocytes, alkaline phosphatase, bicarbonate, calcium, creatinine, globulin, glucose, phosphorus, potassium, sodium, and total protein. There was no significant difference in blood cell count or serum biochemistry values between radio-collared ( n = 17) and noncollared ( n = 47) martens. Animals seropositive for T. gondii were found to have significantly higher ( P < 0.05) eosinophil and globulin levels than seronegative animals. The primary natural cause for mortality of radio-collared American martens was predation. Histologic examinations revealed a high percentage (60%) of martens with verminous or granulomatous pneumonia.
Luteal phase deficiency: abnormal gonadotropin and progesterone secretion patterns.
Soules, M R; Clifton, D K; Cohen, N L; Bremner, W J; Steiner, R A
1989-10-01
Luteal phase deficiency (LPD) is a reproductive disorder associated with infertility and spontaneous abortion. This study was undertaken to determine whether LPD might be related to an abnormal pattern of gonadotropin secretion. We tested this hypothesis by evaluating the pattern of pulsatile LH secretion in both the follicular and luteal phases of the menstrual cycle in normal women (n = 21) and women with LPD (n = 20), which was diagnosed on the basis of two out of phase endometrial biopsies. In addition, we sought to determine whether changes in progesterone (P) pulse patterns could account for the decrease in average serum P levels in women with LPD. To this end, we examined the pulse patterns of P and compared these patterns between normal women and those with LPD. Frequent blood sampling was performed in both groups to determine their respective hormone secretion patterns. In the follicular phase, blood samples were obtained every 10 min for 12 h; in the luteal phase the samples were obtained every 10 min for 12 h; in the luteal LH, FSH, and P were assayed in each sample. Pulse detection was performed by an adaptive threshold method of pulse analysis. The LH pulse frequency was significantly higher in the women with LPD than in the normal women in the early follicular phase [P less than 0.05; LPD, 12.8 +/- 1.4 (+/- SE); normal, 8.2 +/- 0.7 pulses/12 h]. LH pulse frequency was similar in the early and late follicular phases in the women with LPD, whereas it was higher in the late follicular phase in normal women. Mean serum FSH levels were not different between groups in both the early and late follicular phases. In the luteal phase the P pulse amplitude and mean serum P level were significantly lower in the LPD group than in the normal women (P less than 0.01). We conclude that 1) a too rapid LH pulse pattern in the early follicular phase may lead to inadequate LH support of the corpus luteum and become manifest as LPD; 2) the mechanism for inadequate P secretion in LPD is decreased P pulse amplitude; 3) the finding of similar serum FSH levels in the two groups in both the early and late follicular phases did not support compromised folliculogenesis as an etiological factor for LPD.
Magnarelli, L A; Dumler, J S; Anderson, J F; Johnson, R C; Fikrig, E
1995-11-01
Serum specimens from persons with or without Lyme borreliosis were analyzed by indirect fluorescent antibody staining methods for total immunoglobulins to Babesia microti, Ehrlichia chaffeensis (Arkansas strain), and Ehrlichia equi (MRK strain). There was serologic evidence of human exposure to multiple tick-borne agents in 15 (6.6%) of 227 serum samples obtained in Connecticut and Minnesota. Of these, 10 serum samples were from Connecticut patients who had erythema migrans and antibodies to Borrelia burgdorferi (range, 1:160 to 1:40, 960). A maximal antibody titer of 1:640 was noted for a B. microti infection, whereas titration end points of 1:640 and 1:1,280 were recorded for E. chaffeensis and E. equi seropositives, respectively. In specificity tests, there was no cross-reactivity among the antisera and antigens tested for the four tick-borne pathogens. On the basis of serologic testing, a small group of persons who had Lyme borreliosis had been exposed to one or more other tick-borne agents, but there was no clinical diagnosis of babesiosis or ehrlichiosis. Therefore, if the clinical picture is unclear or multiple tick-associated illnesses are suspected, more extensive laboratory testing is suggested.
Xu, Hui; Wang, Shuyu
2012-04-29
In this study, a porous polypropylene frit was coated with polydimethylsiloxane (PDMS) as extraction medium, based on the home-made PDMS-frit, a rapid, simple and sensitive sorptive extraction method was established for analysis of potential biomarkers of lung cancer (hexanal and heptanal) in human serum samples. In the method, derivatization and extraction occurred simultaneously on the PDMS-frit, then the loaded frit was ultrasonically desorbed in acetonitrile. Polymerization, derivatization-extraction and desorption conditions were optimized. Under the optimal conditions, satisfactory results were gained, a wide linear application range was obtained in the range of 0.002-5.0 μmol L(-1) (R>0.997) for two aldehydes, the detection limits (SN(-1)=3) were 0.5 nmol L(-1) for hexanal and 0.4 nmol L(-1) for heptanal. The relative standard deviations (RSDs, n=5) of the method were below 7.9% and the recoveries were above 72.7% for the spiked serum. All these results hint that the proposed method is potential for disease markers analysis in complex biological samples. Copyright © 2012 Elsevier B.V. All rights reserved.
González-Domínguez, Raúl; García, Antonia; García-Barrera, Tamara; Barbas, Coral; Gómez-Ariza, José Luis
2014-12-01
There is high interest in the discovery of early diagnostic biomarkers of Alzheimer's disease, for which metabolomics exhibits a great potential. In this work, a metabolomic approach based on ultrafiltration and analysis by CE-MS has been used to obtain representative fingerprints of polar metabolites from serum samples in order to distinguish between patients with Alzheimer's disease, mild cognitive impairment, and healthy controls. By the use of partial least squares discriminant analysis it was possible to classify patients according to the disease stage and then identify potential markers. Significant increase was observed with progression of disease in levels of choline, creatinine, asymmetric dimethyl-arginine, homocysteine-cysteine disulfide, phenylalanyl-phenylalanine, and different medium chain acylcarnitines. On the other hand, asparagine, methionine, histidine, carnitine, acetyl-spermidine, and C5-carnitine were reduced in these serum samples. In this way, multiple essential pathways were found implicated in the underlying pathology, such as oxidative stress or defects in energy metabolism. However, the most interesting results are related to the association of several vascular risk factors with Alzheimer's disease. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Baillargeon, Paul; Arango-Sabogal, Juan C; Wellemans, Vincent; Fecteau, Gilles
2017-04-01
The objective of this study was to determine if precolostral blood samples are useful to detect apparent fetal infections with bovine viral diarrhea (BVD) and infectious bovine rhinotracheitis (IBR) viruses. A convenience sample of 317 sera from 50 Canadian herds was used in the study. Antibody level was measured using 2 commercial IBR and BVD ELISA kits. Precolostral status of sera was confirmed on 304 samples using serum gamma-glutamyl transferase activity. Postcolostral serum samples yielded a higher proportion of positive results to IBR (OR = 86; 95% CI: 17.8 to 415.7) and BVD (OR = 199.3; 95% CI: 41.7 to 952.3) than did precolostral samples. All positive precolostral serum samples ( n = 7 of 304) originated from calves born to vaccinated cows. Postcolostral positive serum samples ( n = 11 of 13) originated mostly (60%) from calves born to non-vaccinated cows. Precolostral serum sampling can detect apparent fetal infections in a herd.
Wang, Hong; Li, Wei-Rong; Guo, Xiao-Feng; Zhang, Hua-Shan
2007-04-01
The application of near-infrared (NIR) dyes (lambda (em) > 750 nm) to the analysis of biological samples shows much promise, because the long emission wavelengths of such dyes allow interferences from biomolecule matrices to be minimized. In this paper, a novel NIR dye, 5,5'-dicarboxy-1,1'-disulfobutyl-3,3,3',3'-tetramethylindotricarbocyanine (DCDSTCY) has been developed for the spectrophotometric determination of total protein in serum. Under acidic conditions, the binding of DCDSTCY to proteins caused a new peak at 878 nm, the height of which was proportional to the concentration of protein. The linear range of the method was found to be 0.04-0.5 microg mL(-1) for bovine serum albumin (BSA) and human serum albumin (HSA), and detection limits of 5 ng mL(-1) were obtained for these substances. The maximum binding number of BSA with DCDSTCY was measured to be 133. The method proposed here has been applied to the quantitation of total protein in serum, and recoveries of 96.6-104% were achieved. Figure Near-infrared probe for protein determination.
The Role of Trace Elements in Tinnitus.
Yaşar, Mehmet; Şahin, Mehmet İlhan; Karakükçü, Çiğdem; Güneri, Erhan; Doğan, Murat; Sağıt, Mustafa
2017-03-01
In this study, we aimed to investigate the role of three trace elements, namely, zinc, copper, and lead, in tinnitus by analyzing the serum level of copper and lead and both the serum and tissue level of zinc. Eighty patients, who applied to outpatient otolaryngology clinic with the complaints of having tinnitus, and 28 healthy volunteers were included. High-frequency audiometry was performed, and participants who had hearing loss according to the pure tone average were excluded; tinnitus frequency and loudness were determined and tinnitus reaction questionnaire scores were obtained from the patients. Of all the participants, serum zinc, copper, and lead values were measured; moreover, zinc levels were examined in hair samples. The levels of trace elements were compared between tinnitus and control groups. The level of copper was found to be significantly lower in the tinnitus group (p = 0.02), but there was no significant difference between the groups in terms of the levels of zinc, neither in serum nor in hair, and lead in serum (p > 0.05). The lack of trace elements, especially that of "zinc," have been doubted for the etiopathogenesis of tinnitus in the literature; however, we only found copper levels to be low in patients having tinnitus.
Metabolic profile of serum and follicular fluid from postpartum dairy cows during summer and winter.
Alves, Benner G; Alves, Kele A; Martins, Muller C; Braga, Lucas S; Silva, Thiago H; Alves, Bruna G; Santos, Ricarda M; Silva, Thiago V; Viu, Marco A O; Beletti, Marcello E; Jacomini, José O; Gambarini, Maria L
2014-01-01
This study was designed to monitor the biochemical profiles of serum and follicular fluid (FF) of postpartum dairy cows during the summer (n=30) and winter (n=30). Blood and FF (follicles ≥ 9 mm) were obtained from Girolando cows at 30, 45, 60, 75 and 90 days postpartum. The samples were collected and analysed to determine glucose, total cholesterol (TC), triglyceride (TG), urea, sodium (Na), potassium (K) and calcium (Ca) levels. Throughout the study, the following clinical variables were measured: rectal temperature (RT), respiratory rate (RR) and body condition score (BCS). In addition, the temperature humidity index (THI) was calculated for each season. During the summer season, THI was higher, BCS decreased, there was an increase in RT, and glucose, urea, Na and K serum levels were decreased (P<0.05). The levels of TC, TG, urea, K and Ca in follicular fluid increased (P<0.05). Positive correlations (P<0.05) were observed between the serum and FF levels for glucose (r=0.29), TC (r=0.24) and Ca (r=0.30). Therefore, the biochemical profile of serum and FF of dairy cows under summer heat-stress conditions demonstrates marked changes that may impair fertility during lactation.
One-day fluorescent-antibody procedure for detecting salmonellae in frozen and dried foods.
Goepfert, J M; Mann, M E; Hicks, R
1970-12-01
The indirect fluorescent-antibody technique was used to examine 422 food samples for the presence of salmonellae. A cultural phase involving a 16-hr preenrichment in buffered nutrient broth-milk medium followed by a 4- to 5-hr subculture into fresh medium of the same composition was evaluated. This procedure yielded a sufficient population of salmonellae so that no false-negative results were obtained. Of the 31 false-positives obtained, 12 samples yielded positive cultural results upon extensive subculture of the original enrichment broths. Yeast cells and both vegetative and spore forms of bacilli were observed to fluoresce when stained with anti-Salmonella serum. Efforts to ascertain the cause of these cross-reactions and several alternate explanations are discussed.
Yuki, Masashi; Itoh, Hiroshi; Takase, Katsuaki
2010-03-01
alpha-1-acid glycoprotein (AGP) is an acute-phase protein and a serum marker of inflammation and neoplasia in humans. AGP concentrations in diseased dogs and the potential effects of age, breed, and sex have not been elucidated. The purpose of this study was to examine differences in AGP concentration based on age, sex, and breed in a large population of clinically healthy dogs and to compare AGP concentrations in dogs with various diseases. Serum was obtained from clinically healthy puppies (n=74) and adults (n=172) of both sexes, and included mongrels (n=205) and Beagles (n=41). Serum also was obtained from 192 dogs with various diseases, including 8 with pyometra that were sampled before, and 1, 2, 3, and 10 days after surgery. AGP concentration was measured by single radial immunodiffusion. Statistical comparisons were made among age, sex, breed, and disease groups. Serum AGP in healthy adult mongrels was 364+/-106 mg/L (reference interval, 152-576 mg/L). AGP was lowest in newborns (n=11, 122+/-54 mg/L) and gradually increased to adult levels by 3 months of age. Median AGP concentration was highest in dogs with parvovirus (n=17, 2100 mg/L), distemper (n=7, 1250 mg/L), and pyometra (n=18, 2480 mg/L) and was also significantly higher in dogs with acute filariasis, renal failure, urolithiasis, pancreatitis, hepatitis, trauma, hyperadrenocorticism, and immune-mediated hemolytic anemia. Dogs with acute filariasis and acute hepatopathy had significantly higher AGP concentrations than dogs with chronic filariasis and chronic hepatopathy. Serum AGP concentration decreased gradually following surgery for pyometra but remained increased after 10 days (896+/-175 mg/L). Because of significantly lower AGP in puppies, the age of dogs should be considered when using AGP as a marker of disease. Serum AGP may be a useful marker of inflammatory disease in dogs and may help differentiate acute and chronic stages of disease.
Optimal combinations of acute phase proteins for detecting infectious disease in pigs.
Heegaard, Peter M H; Stockmarr, Anders; Piñeiro, Matilde; Carpintero, Rakel; Lampreave, Fermin; Campbell, Fiona M; Eckersall, P David; Toussaint, Mathilda J M; Gruys, Erik; Sorensen, Nanna Skall
2011-03-17
The acute phase protein (APP) response is an early systemic sign of disease, detected as substantial changes in APP serum concentrations and most disease states involving inflammatory reactions give rise to APP responses. To obtain a detailed picture of the general utility of porcine APPs to detect any disease with an inflammatory component seven porcine APPs were analysed in serum sampled at regular intervals in six different experimental challenge groups of pigs, including three bacterial (Actinobacillus pleuropneumoniae, Streptococcus suis, Mycoplasma hyosynoviae), one parasitic (Toxoplasma gondii) and one viral (porcine respiratory and reproductive syndrome virus) infection and one aseptic inflammation. Immunochemical analyses of seven APPs, four positive (C-reactive protein (CRP), haptoglobin (Hp), pig major acute phase protein (pigMAP) and serum amyloid A (SAA)) and three negative (albumin, transthyretin, and apolipoprotein A1 (apoA1)) were performed in the more than 400 serum samples constituting the serum panel. This was followed by advanced statistical treatment of the data using a multi-step procedure which included defining cut-off values and calculating detection probabilities for single APPs and for APP combinations. Combinations of APPs allowed the detection of disease more sensitively than any individual APP and the best three-protein combinations were CRP, apoA1, pigMAP and CRP, apoA1, Hp, respectively, closely followed by the two-protein combinations CRP, pigMAP and apoA1, pigMAP, respectively. For the practical use of such combinations, methodology is described for establishing individual APP threshold values, above which, for any APP in the combination, ongoing infection/inflammation is indicated.
Changes of human serum proteome profile during 7-day “dry” immersion
NASA Astrophysics Data System (ADS)
Pakharukova, N. A.; Pastushkova, L. Kh.; Larina, I. M.; Grigoriev, A. I.
2011-05-01
The aim of this study was to characterize changes of serum proteome profile during 7-day "dry" immersion (DI). The experiment with DI consisted of three series: control group without countermeasures (10 men), with using mechanical stimulation (6 men) and low-frequency myostimulation (5 men) as preventive means. Serum samples were fractionated using ClinProt robot (Bruker Daltonics) on magnetic beads (weak cation exchange magnetic beads—MB WCX) prior to mass-spectral profiling. It was obtained 170 peaks after fractionation of serum samples in each group. On 7th immersion day peak areas of fibrinopeptide A ( m/ z=1206; 1464), angiotensin II ( m/ z=1051), high molecular mass kininogen fragment ( m/ z=2133 Da) and C3-fragment of the complement system ( m/ z=1350 Da) were significantly decreased comparing with pre-experimental values of all experimental series. Peak areas of apolipoprotein C III ( m/ z=9419) and C4a fragment of the complement system ( m/ z=3206 Da) were increased. On 7th day of the recovery peak areas of all changed peaks were not close to pre-experimental values. This fact provided evidence of incomplete recovery of an organism after DI. The depth of the alterations had considerable individual variability. Thereby the detected changes of serum proteome profile in the experiment. They indicated a reorganization of the hormonal, immune systems and lipid metabolism. The use of myostimulation and mechanical stimulation as countermeasures partly compensated adverse effects of 7-day dry immersion on the parameters of coagulation system (fibrinopeptide A) and lipid metabolism (apolipoprotein CIII).
Singh, Sonu Sundd; Jain, Manish; Sharma, Kuldeep; Shah, Bhavin; Vyas, Meghna; Thakkar, Purav; Shah, Ruchy; Singh, Shriprakash; Lohray, Brajbhushan
2005-04-25
A new method was developed for determination of itopride in human serum by reversed phase high-performance liquid chromatography (HPLC) with fluorescence detection (excitation at 291 nm and emission at 342 nm). The method employed one-step extraction of itopride from serum matrix with a mixture of tert-butyl methyl ether and dichloromethane (70:30, v/v) using etoricoxib as an internal standard. Chromatographic separation was obtained within 12.0 min using a reverse phase YMC-Pack AM ODS column (250 mm x 4.6 mm, 5 microm) and an isocratic mobile phase constituting of a mixture of 0.05% tri-fluoro acetic acid in water and acetonitrile (75:25, v/v) flowing at a flow rate of 1.0 ml/min. The method was linear in the range of 14.0 ng/ml to 1000.0 ng/ml. The lower limit of quantitation (LLOQ) was 14.0 ng/ml. Average recovery of itopride and the internal standard from the biological matrix was more than 66.04 and 64.57%, respectively. The inter-day accuracy of the drug containing serum samples was more than 97.81% with a precision of 2.31-3.68%. The intra-day accuracy was 96.91% or more with a precision of 5.17-9.50%. Serum samples containing itopride were stable for 180.0 days at -70+/-5 degrees C and for 24.0 h at ambient temperature (25+/-5 degrees C). The method was successfully applied to the bioequivalence study of itopride in healthy, male human subjects.
Hypobaric Hypoxia Exacerbates the Neuroinflammatory Response to Traumatic Brain Injury
Goodman, Michael D.; Makley, Amy T.; Huber, Nathan L.; Clarke, Callisia N.; Friend, Lou Ann W.; Schuster, Rebecca M.; Bailey, Stephanie R.; Barnes, Stephen L.; Dorlac, Warren C.; Johannigman, Jay A.; Lentsch, Alex B.; Pritts, Timothy A.
2015-01-01
Objective To determine the inflammatory effects of time-dependent exposure to the hypobaric environment of simulated aeromedical evacuation following traumatic brain injury (TBI). Methods Mice were subjected to a blunt TBI or sham injury. Righting reflex response (RRR) time was assessed as an indicator of neurologic recovery. Three or 24 h (Early and Delayed groups, respectively) after TBI, mice were exposed to hypobaric flight conditions (Fly) or ground-level control (No Fly) for 5 h. Arterial blood gas samples were obtained from all groups during simulated flight. Serum and cortical brain samples were analyzed for inflammatory cytokines after flight. Neuron specific enolase (NSE) was measured as a serum biomarker of TBI severity. Results TBI resulted in prolonged RRR time compared with sham injury. After TBI alone, serum levels of interleukin-6 (IL-6) and keratinocyte-derived chemokine (KC) were increased by 6 h post-injury. Simulated flight significantly reduced arterial oxygen saturation levels in the Fly group. Post-injury altitude exposure increased cerebral levels of IL-6 and macrophage inflammatory protein-1α (MIP-1α), as well as serum NSE in the Early but not Delayed Flight group compared to ground-level controls. Conclusions The hypobaric environment of aero-medical evacuation results in significant hypoxia. Early, but not delayed, exposure to a hypobaric environment following TBI increases the neuroinflammatory response to injury and the severity of secondary brain injury. Optimization of the post-injury time to fly using serum cytokine and biomarker levels may reduce the potential secondary cerebral injury induced by aeromedical evacuation. PMID:20850781
Fractionation of canine serum magnesium.
Schenck, Patricia A
2005-06-01
Serum total magnesium (tMg) consists of 3 fractions: ionized magnesium (iMg), protein-bound magnesium (pbMg), and complexed magnesium (cMg). Serum iMg may be measured by an ion-selective electrode, but determination of pbMg and cMg has not been attempted in dogs. The objectives of this study were to assess the validity of a micropartition system to fractionate serum tMg and to establish reference intervals for pbMg, cMg, and iMg in clinically normal dogs using this method. Serum samples from 10 clinically healthy dogs were fractionated using a micropartition system (Centrifree YM-30, Amicon Corp, Lexington, MA, USA). Serum tMg and iMg were measured in whole serum, and tMg was also measured in the ultrafiltrate. Concentration of cMg was obtained by the subtraction of iMg from tMg concentrations of the ultrafiltrate. Protein-bound Mg was calculated by subtracting the tMg concentration of the ultrafiltrate from the tMg concentration of whole serum. Results for pbMg and cMg using the micropartition system showed good reproducibility. Determination of tMg and iMg had acceptable inter- and intra-assay precision. Concentrations of iMg, cMg, and pbMg were 0.50 +/- 0.05 mmol/L, 0.05 +/- 0.04 mmol/L, and 0.24 +/- 0.04 mmol/L, representing 63%, 6%, and 31% of the tMg concentration, respectively. The micropartition system was a reproducible means to accurately assess cMg and pbMg concentrations in dogs.
Meta-analysis of serum lactate dehydrogenase and prognosis for osteosarcoma.
Fu, Yucheng; Lan, Tao; Cai, Hongliu; Lu, Anwei; Yu, Wei
2018-05-01
A large number of studies have reported the relationships between serum lactate dehydrogenase (LDH) and prognosis of osteosarcoma. However, the result is still controversial and no consensus has been reached. Therefore, we performed a meta-analysis to evaluate the prognostic role of serum LDH in osteosarcoma patients. We performed the systematic computerized search for eligible articles from PubMed, Embase, and Cochrane databases until December 21, 2017. The pooled hazard ratio (HR) and 95% confidence intervals (CIs) of overall survival (OS) and event-free survival (EFS) were obtained to assess the prognostic value of serum LDH. A total of 18 studies with 2543 osteosarcoma patients were included. Overall, 15 studies assessed the elevated serum LDH level on OS and the pooled HR was 1.87 (95% CI = 1.58-2.20). Meanwhile, the pooled HR to evaluate the relationship between serum LDH and EFS in 9 studies was 1.78 (95% CI = 1.51-2.10). The same results were acquired when these studies were stratified by Enneking stage, geographic region, and sample size. No heterogeneity existed between these subgroups (P > .05). Begg's funnel plot and Egger's test (OS: P = .04; EFS: P = .34) showed that possible publication bias might exist in OS studies. Sensitivity analysis suggested the pooled HR was robust. This meta-analysis demonstrates that elevated serum LDH level is apparently associated with lower EFS rate and serum LDH could be a prognostic biomarker for osteosarcoma patients.
Radiation-Induced Changes in Serum Lipidome of Head and Neck Cancer Patients
Jelonek, Karol; Pietrowska, Monika; Ros, Malgorzata; Zagdanski, Adam; Suchwalko, Agnieszka; Polanska, Joanna; Marczyk, Michal; Rutkowski, Tomasz; Skladowski, Krzysztof; Clench, Malcolm R.; Widlak, Piotr
2014-01-01
Cancer radiotherapy (RT) induces response of the whole patient’s body that could be detected at the blood level. We aimed to identify changes induced in serum lipidome during RT and characterize their association with doses and volumes of irradiated tissue. Sixty-six patients treated with conformal RT because of head and neck cancer were enrolled in the study. Blood samples were collected before, during and about one month after the end of RT. Lipid extracts were analyzed using MALDI-oa-ToF mass spectrometry in positive ionization mode. The major changes were observed when pre-treatment and within-treatment samples were compared. Levels of several identified phosphatidylcholines, including (PC34), (PC36) and (PC38) variants, and lysophosphatidylcholines, including (LPC16) and (LPC18) variants, were first significantly decreased and then increased in post-treatment samples. Intensities of changes were correlated with doses of radiation received by patients. Of note, such correlations were more frequent when low-to-medium doses of radiation delivered during conformal RT to large volumes of normal tissues were analyzed. Additionally, some radiation-induced changes in serum lipidome were associated with toxicity of the treatment. Obtained results indicated the involvement of choline-related signaling and potential biological importance of exposure to clinically low/medium doses of radiation in patient’s body response to radiation. PMID:24747595
Analysis of urinary PSA glycosylation is not indicative of high-risk prostate cancer.
Barrabés, Sílvia; Llop, Esther; Ferrer-Batallé, Montserrat; Ramírez, Manel; Aleixandre, Rosa N; Perry, Antoinette S; de Llorens, Rafael; Peracaula, Rosa
2017-07-01
The levels of core fucosylation and α2,3-linked sialic acid in serum Prostate Specific Antigen (PSA), using the lectins Pholiota squarrosa lectin (PhoSL) and Sambucus nigra agglutinin (SNA), can discriminate between Benign Prostatic Hyperplasia (BPH) and indolent prostate cancer (PCa) from aggressive PCa. In the present work we evaluated whether these glycosylation determinants could also be altered in urinary PSA obtained after digital rectal examination (DRE) and could also be useful for diagnosis determinations. For this purpose, α2,6-sialic acid and α1,6-fucose levels of urinary PSA from 53 patients, 18 biopsy-negative and 35 PCa patients of different aggressiveness degree, were analyzed by sandwich ELLA (Enzyme Linked Lectin Assay) using PhoSL and SNA. Changes in the levels of specific glycosylation determinants, that in serum PSA samples were indicative of PCa aggressiveness, were not found in PSA from DRE urine samples. Although urine is a simpler matrix for analyzing PSA glycosylation compared to serum, an immunopurification step was necessary to specifically detect the glycans on the PSA molecule. Those specific glycosylation determinants on urinary PSA were however not useful to improve PCa diagnosis. This could be probably due to the low proportion of PSA from the tumor in urine samples, which precludes the identification of aberrantly glycosylated PSA. Copyright © 2017 Elsevier B.V. All rights reserved.
Detection of reticuloendotheliosis virus as a contaminant of fowl pox vaccines.
Awad, A M; Abd El-Hamid, H S; Abou Rawash, A A; Ibrahim, H H
2010-11-01
This study was designed to detect reticuloendotheliosis virus (REV) as a contaminant in fowl pox vaccines. A total of 30 fowl pox vaccine samples were examined for the presence of REV using both in vitro and in vivo methods. In in vitro testing, the fowl pox vaccine samples were inoculated into chicken embryo fibroblast cultures prepared from specific-pathogen-free embryonated chicken eggs, and the cultures were examined using PCR to detect REV. In in vivo testing, each fowl pox vaccine sample was inoculated into 5-d-old specific-pathogen-free chicks, which were kept under observation for up to 12 wk postinoculation; serum samples were collected at 15, 30, and 45 d postinoculation for the detection of REV-specific antibodies using ELISA. Tissue samples were collected at 8 and 12 wk postinoculation for histopathological examination. Of the tested vaccines, only one imported vaccine sample tested positive for REV using PCR. Serum samples collected from chicks infected with the PCR-positive vaccine batch also tested positive for REV-specific antibodies using ELISA. Histopathological examination of the liver, spleen, and bursa of Fabricius demonstrated the presence of tumor cells in these organs, confirming the results obtained using PCR and ELISA, and indicating that the sample was contaminated with REV. These data clearly indicate that the screening of all commercial poultry vaccines for viruses is an important factor in assuring the biosafety of animal vaccines.
Drug residues in serum of dogs receiving anticancer chemotherapy.
Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D
2010-01-01
The presence of drug residues in blood samples can represent an occupational hazard. However, studies on cytotoxic drug residues in serum of dogs are lacking in veterinary oncology. To evaluate possible occupational hazards associated with handling of blood samples from dogs receiving oncolytic drugs 7 days after treatment. Twenty-seven client-owned dogs treated for lymphoma or mast cell tumors with vincristine, vinblastine, cyclophosphamide, or doxorubicin. Prospective, observational study. Serum samples were either taken 7 days after administration of vincristine, cyclophosphamide, doxorubicin (lymphoma), and vinblastine (mast cell tumor), or 1-2 days after the last concurrent oral administration of cyclophosphamide (mast cell tumor). Additionally, serum was collected within 5 minutes of treatment. Measurement of drug residues in serum was performed by liquid chromatography tandem mass spectrometry (LC/MS/MS). In 33 samples collected within 5 minute of treatment, the median serum concentrations were vincristine: 37 microg/L (range: 11-87 microg/L), vinblastine: 13 microg/L (range: 13-35 microg/L), cyclophosphamide: 2,484 microg/L (range: 1,209-2,778 microg/L), doxorubicin: 404 microg/L (range: 234-528 microg/L). In 81 serum samples collected 7 days after treatment vinblastine (7 microg/L) was detected in 1 sample, and cyclophosphamide (7 and 9 microg/L) in 2 samples collected 1-2 days after oral administration of cyclophosphamide. Medications were not detected in any of the other samples. Handling of blood samples from dogs receiving oncolytic chemotherapy 7 days after treatment with vincristine, vinblastine, cyclophosphamide, and doxorubicin should not present a health hazard.
Verhoeven, Cornelia J; Farid, Waqar R R; Roest, Henk P; Ramakrishnaiah, Vedashree; de Ruiter, Petra E; de Jonge, Jeroen; Kwekkeboom, Jaap; Metselaar, Herold J; Tilanus, Hugo W; Kazemier, Geert; Ijzermans, Jan N M; van der Laan, Luc J W
2016-06-01
Extracellular microRNAs (miRNAs) in serum and bile are currently under intense investigation for biomarker purposes in liver disease. However, the directions and pathways by which miRNAs are released from hepatic cells remains largely unknown. Here, we investigated the release of hepatocyte and cholangiocyte-derived miRNAs (HDmiRs and CDmiRs) into blood and bile during various (patho)physiological hepatic conditions. MiRNA release was analysed using longitudinally collected tissue and paired bile and serum samples (n = 124) that were obtained from liver transplant recipients during follow-up. Cell-type specificity of HDmiRs and CDmiRs was confirmed in liver and common bile duct biopsies (P < 0.001). Analysis of paired bile and serum samples showed up to 20-times higher miRNA-levels in bile compared to serum (P < 0.0001). Fractionation of bile showed the majority of miRNAs being present in the unpelletable supernatant, where protein conjunctions protect miRNAs against degradation (P < 0.0001). During episodes of liver injury and histologically proven rejection in liver transplant recipients, relative HDmiR-levels in bile decreased while its levels in serum increased (P ≤ 0.015). Simultaneously, relative CDmiR-levels in bile significantly increased, while their levels in serum decreased. Related to liver excretory function, a strong positive correlation was observed between HDmiR-122 levels and bilirubin excretion into bile (R = 0.694, P < 0.0001), whereas CDmiRs showed an inverse correlation (P < 0.05). During impaired excretory function and injury, the liver shows polarized release of extracellular HDmiRs and CDmiRs. This sheds new light on the biology of hepatic miRNA release which is relevant for the interpretation of hepatic miRNAs as biomarkers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sayed-Hassan, Rima; Abazid, Nizar; Alourfi, Zaynab
2014-01-01
Vitamin D deficiency (25-hydroxyvitamin D (25OHD) <25 nmol/L) was common in a convenience sample of apparently healthy Syrian adults. Female gender, season, and concealing clothing were independent predictors of vitamin D deficiency. Community-based research is needed to identify vulnerable subgroups and inform public health actions. Optimal vitamin D status for bone health has been inferred from the determination of serum 25OHD levels below which there is an increase in serum parathyroid hormone (PTH). Studies worldwide showed high prevalence of hypovitaminosis D even in sunny countries. There is little evidence about its prevalence among Syrian adult population. We aimed to assess the serum levels of 25OHD and factors related to vitamin D inadequacy and its relation to serum PTH and calcium among apparently healthy adults. Serum 25OHD and PTH measurements were obtained from 372 subjects aged 18-62 years living in Damascus and its surroundings, between April 2011 and March 2013. Binary logistic regression was used to assess risk factors for hypovitaminosis D. The mean (standard deviation (SD)) 25OHD level was 24.7 (16.9) nmol/L [9.8 (6.7) ng/mL] and was higher in men than women (p < 0.001). Levels <25, <50, and <75 nmol/L were detected in 61, 90.1, and 99.2 % of the participants, respectively. Season influenced vitamin D status in men but not in women (p < 0.001). Female gender and wearing the veil (hijab) were independent predictors of vitamin D deficiency (25OHD <25 nmol/L). PTH was significantly higher below this threshold (p < 0.001). Serum 25OHD <25 nmol/L, sex, and age ≥ 35 years were statistically significant factors for PTH elevation. Vitamin D deficiency was highly prevalent in our sample. Further research is needed to identify population groups vulnerable for hypovitaminosis D and specify its predictors and inform the necessary public health measures.
Prolonged weightlessness and humoral immunity
NASA Technical Reports Server (NTRS)
Voss, E. W., Jr.
1984-01-01
Preflight, inflight, and postflight serum samples obtained from crewmen aboard STS-9 were analyzed for immunoglobulin content. Control studies for circadian rhythm were conducted to further validate the analyses. Quantitation of immunoglobulins G, M, A, D, and E indicated relatively minor fluctuations in the concentration of each class of immunoglobulin during the experiment. Thus, microgravity effects on immunoglobulin levels during a 10-day flight were considered insignificant.
Linton, Linda; Taylor, Monica; Dunn, Sheila; Martin, Lisa; Chavez, Sonia; Stanitz, Greg; Huszti, Ella; Minkin, Salomon; Boyd, Norman
2016-01-01
In previous work in young women aged 15-30 years we measured breast water and fat using MR and obtained blood for hormone assays on the same day in the follicular phase of the menstrual cycle. Only serum growth hormone levels and sex hormone binding globulin (SHBG) were significantly associated with percent breast water after adjustment for covariates. The sex hormones estradiol, progesterone and testosterone were not associated with percent water in the breast in the follicular phase of the menstrual cycle. In the present study we have examined the association of percent breast water with serum levels of sex hormones in both follicular and luteal phase of the menstrual cycle. In 315 healthy white Caucasian young women aged 15-30 with regular menstrual cycles who had not used oral contraceptives or other hormones in the previous 6 months, we used MR to determine percent breast water, and obtained blood samples for hormone assays within 10 days of the onset of the most recent menstrual cycle (follicular phase) of the cycle on the same day as the MR scan, and a second blood sample on days 19-24 of the cycle. Serum progesterone levels of > = 5 mmol/L in days 19-24 were used to define the 225 subjects with ovulatory menstrual cycles, whose data are the subject of the analyses shown here. SHBG was positively associated with percent water in both follicular and luteal phases of the menstrual cycle. Total and free estradiol and total and free testosterone were not associated with percent water in the follicular phase, but in young women with ovulatory cycles, were all negatively associated with percent water in the luteal phase. Our results from young women aged 15-30 years add to the evidence that the extent of fibroglandular tissue in the breast that is reflected in both mammographic density and breast water is associated positively with higher serum levels of SHBG, but not with higher levels of sex hormones.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iriyama, Chisako; Tomita, Akihiro, E-mail: atomita@med.nagoya-u.ac.jp; Hoshino, Hideaki
2012-03-23
Highlights: Black-Right-Pointing-Pointer Circulating DNAs (CDs) can be used to detect genetic/epigenetic abnormalities in MDS. Black-Right-Pointing-Pointer Epigenetic changes can be detected more sensitively when using plasma DNA than PBMNC. Black-Right-Pointing-Pointer Mutation ratio in CDs may reflect the ratio in stem cell population in bone marrow. Black-Right-Pointing-Pointer Using CDs can be a safer alternate strategy compared to bone marrow aspiration. -- Abstract: Myelodysplastic syndrome (MDS) is a hematopoietic stem cell disorder. Several genetic/epigenetic abnormalities are deeply associated with the pathogenesis of MDS. Although bone marrow (BM) aspiration is a common strategy to obtain MDS cells for evaluating their genetic/epigenetic abnormalities, BM aspirationmore » is difficult to perform repeatedly to obtain serial samples because of pain and safety concerns. Here, we report that circulating cell-free DNAs from plasma and serum of patients with MDS can be used to detect genetic/epigenetic abnormalities. The plasma DNA concentration was found to be relatively high in patients with higher blast cell counts in BM, and accumulation of DNA fragments from mono-/di-nucleosomes was confirmed. Using serial peripheral blood (PB) samples from patients treated with hypomethylating agents, global methylation analysis using bisulfite pyrosequencing was performed at the specific CpG sites of the LINE-1 promoter. The results confirmed a decrease of the methylation percentage after treatment with azacitidine (days 3-9) using DNAs from plasma, serum, and PB mono-nuclear cells (PBMNC). Plasma DNA tends to show more rapid change at days 3 and 6 compared with serum DNA and PBMNC. Furthermore, the TET2 gene mutation in DNAs from plasma, serum, and BM cells was quantitated by pyrosequencing analysis. The existence ratio of mutated genes in plasma and serum DNA showed almost equivalent level with that in the CD34+/38- stem cell population in BM. These data suggest that genetic/epigenetic analyses using PB circulating DNA can be a safer and painless alternative to using BM cells.« less
Liu, Tao; Hou, Ying; Dai, Ting-Jun; Yan, Chuan-Zhu
2017-09-05
The immunopathologic mechanism underlying dermatomyositis (DM) and polymyositis (PM) remains poorly understood. Many cytokines play a pathogenic role in DM and PM. Interleukin 21 (IL-21) has a pleiotropic effect on inflammation regulation. This study aimed to detect the serum IL-21 level and investigate the expression of IL-21 and IL-21 receptor (IL-21R) in muscle tissues of patients with DM and PM. Biopsied muscle samples were obtained from 11 patients with DM, 12 with PM, and six controls; mRNA levels of IL-21 and IL-21R were analyzed by real-time quantitative reverse transcription-polymerase chain reaction; and immunohistochemical staining was used to evaluate the protein expression of IL-21 and IL-21R. Serum samples were obtained from 36 patients with DM, 19 with PM, and 20 healthy controls. The serum IL-21 level was detected by enzyme-linked immunosorbent assay. The expression of IL-21 was upregulated in patients with DM and PM. The IL-21 mRNA level was significantly increased in muscle tissues of patients with DM and PM (DM vs. control, P= 0.001; PM vs. control, P= 0.001), whereas IL-21R mRNA level in patients with DM/PM was not statistically different from that of healthy controls. Immunohistochemical staining showed both IL-21 and IL-21R were significantly expressed in the inflammatory cells in muscle tissues of patients with DM and PM. The serum IL-21 level was also significantly higher in patients with DM/PM than in controls (DM vs. control, 49.12 [45.28, 60.07] pg/ml vs. 42.54 [38.69, 48.85] pg/ml, P= 0.001; PM vs. control, 50.77 [44.19, 60.62] pg/ml vs. 42.54 [38.69, 48.85] pg/ml, P= 0.005). IL-21 expression is upregulated in patients with DM and PM in both muscle tissue and serum. In addition, IL-21R protein is highly expressed in affected muscle tissues of patients with DM and PM. IL-21 may play a pathogenic role through IL-21R in patients with DM and PM.
Sukla, Soumi; Ghosh, Anisa; Saha, Rajdeep; De, Abhishek; Adhya, Samit; Biswas, Subhajit
2018-06-13
Zika virus infections have recently been reported in many dengue-endemic areas globally. Both dengue (DENV) and Zika (ZIKV) virus are transmitted by Aedes mosquitoes, raising the possibility of mixed infections in both vector and host. We evaluated DENV and ZIKV prevalence in human and vector samples in Kolkata, a DENV-endemic city. Blood samples were collected from 70 patients presenting dengue-like fever symptoms at a hospital in Kolkata during 2015-16. Serum was obtained and tested for DENV infection by DENV NS1-based ELISA. Adult (n=8) and larval stages (n=12) of Aedes were also collected. A RT-PCR-based screening of both viruses supplemented by amplicon sequencing was performed. Of the 70 samples, 20 DENV NS1-positive serum samples were used for detailed molecular study for DENV infection. Eighteen of these (90 %) were positive by hemi-nested serotype-specific RT-PCR for DENV1/2/3, with four samples showing evidence of DENV2-3 or DENV1-3 mixed infection. None were ZIKV-positive using NS5 or ENV-based PCR, though weak amplification of a DENV1 NS5 sequence was detected in three serum samples indicating cross-reactivity of the primers. All mosquito samples were ZIKV-negative, whereas 5/8 (63 %) of adult mosquitoes and 11/12 (92 %) of larvae were DENV3-positive. Both host and vector samples showed absence of ZIKV but high prevalence of DENV. The high rate of infection of larvae with DENV is suggestive of trans-ovarial transmission that could contribute to the surge of human infections during each post-monsoon season. It would be important to guard against false positives using the available Zika-reporting primer sets.
Novel blood-based microRNA biomarker panel for early diagnosis of chronic pancreatitis
Xin, Lei; Gao, Jun; Wang, Dan; Lin, Jin-Huan; Liao, Zhuan; Ji, Jun-Tao; Du, Ting-Ting; Jiang, Fei; Hu, Liang-Hao; Li, Zhao-Shen
2017-01-01
Chronic pancreatitis (CP) is an inflammatory disease characterized by progressive fibrosis of pancreas. Early diagnosis will improve the prognosis of patients. This study aimed to obtain serum miRNA biomarkers for early diagnosis of CP. In the current study, we analyzed the differentially expressed miRNAs (DEmiRs) of CP patients from Gene Expression Omnibus (GEO), and the DEmiRs in plasma of early CP patients (n = 10) from clinic by miRNA microarrays. Expression levels of DEmiRs were further tested in clinical samples including early CP patients (n = 20), late CP patients (n = 20) and healthy controls (n = 18). The primary endpoints were area under curve (AUC) and expression levels of DEmiRs. Four DEmiRs (hsa-miR-320a-d) were obtained from GEO CP, meanwhile two (hsa-miR-221 and hsa-miR-130a) were identified as distinct biomarkers of early CP by miRNA microarrays. When applied on clinical serum samples, hsa-miR-320a-d were accurate in predicting late CP, while hsa-miR-221 and hsa-miR-130a were accurate in predicting early CP with AUC of 100.0% and 87.5%. Our study indicates that miRNA expression profile is different in early and late CP. Hsa-miR-221 and hsa-miR-130a are biomarkers of early CP, and the panel of the above 6 serum miRNAs has the potential to be applied clinically for early diagnosis of CP. PMID:28074846
Foulstone, M; Reading, C
1982-01-01
Augmentin is a new antibacterial formulation comprised of amoxicillin and the beta-lactamase inhibitor clavulanic acid. In the present paper, the use of high-performance liquid chromatography (HPLC) to provide a rapid assay of the components of Augmentin in body fluids is described. Clavulanic acid was assayed by reacting the sample with imidazole, which readily produces a derivative absorbing at 311 nm. This derivative chromatographs on reverse-phase HPLC columns clear of interfering components in both human serum and urine. Concentrations of clavulanic acid as low as 0.1 microgram/ml were readily detectable in human serum with this procedure. There was no interference from amoxicillin, amoxicillin penicilloic acid, or the acid and alkali degradation products of clavulanic acid when this assay system was used. Amoxicillin in body fluids was assayed directly by HPLC without derivatization. The same chromatographic conditions were employed for the assay of amoxicillin and the clavulanic acid derivative, simplifying the methodology. Amoxicillin, however, was determined of the antibiotic per ml. An alkali blanking procedure for amoxicillin and clavulanic acid is also described which allows the detection of any underlying peaks which may cochromatograph. The use of ultrafiltration to remove protein from serum samples before HPLC was successfully applied to the assay of clavulanic acid and amoxicillin. Ultrafiltration is not an essential procedure for these assays, but it prolongs column life and reduces interference in the amoxicillin assay. Results obtained by HPLC were compared with those obtained by using microbiological assays. PMID:7181486
Walsh, Robert B.; Kelton, David F.; Hietala, Sharon K.; Duffield, Todd F.
2013-01-01
Serum and milk samples from 1229 cows on 22 Ontario dairy farms were individually tested for antibodies specific for bovine leukosis virus (BLV) and Neospora caninum by enzyme-linked immunosorbent assay (ELISA). Antibodies against BLV were present in 361 serum samples (29.4%) and 369 milk samples (30.0%). Comparing the 2 tests, agreement was almost perfect (k = 0.86; 95% CI = 0.83 to 0.90) and the proportions of samples positive were not significantly different (P = 0.56). Both tests identified the same 3 herds free of bovine leukosis virus. Antibodies against N. caninum were detected in 138 serum samples (11.2%), and 111 milk samples (9.0%). Agreement between the 2 tests was moderate (k = 0.52; 95% CI = 0.43 to 0.59). Four herds were free of neosporosis by the serum test, while 10 herds were negative by the milk test. The ELISA on milk samples facilitates sample collection to classify herds free of BLV; the milk N. caninum ELISA was less reliable in predicting herd-level infection. PMID:24082160
Soluble VCAM-1/soluble ICAM-1 ratio is a promising biomarker for diagnosing endometriosis.
Kuessel, L; Wenzl, R; Proestling, K; Balendran, S; Pateisky, P; Yotova; Yerlikaya, G; Streubel, B; Husslein, H
2017-04-01
Do cell adhesion molecules play a role in endometriosis, and can they be used as a biomarker for diagnosing endometriosis? Altered expression of vascular cell adhesion molecule-1 (VCAM-1) and intercellular adhesion molecule-1 (ICAM-1) in the endometrium and peritoneum may play a key role in endometriosis and the soluble VCAM-1/soluble ICAM-1 ratio is a promising biomarker. Cell adhesion molecules are cell surface proteins that mediate cellular adherence, inflammatory and immune responses, and cancer-related biological processes. Altered expression of VCAM-1 and ICAM-1 in women with endometriosis has been investigated previously; however, gene expression levels in tissues and protein levels in the serum have not been investigated in the same patients. We performed a prospective, longitudinal study (the Endometriosis Marker Austria) in patients who underwent a laparoscopy for benign gynecological pathology in a university-based tertiary referral center for endometriosis. From a total of 138 women who were included in the study from July 2013 through September 2014, 97 had not received hormonal treatment for at least 3 months prior to recruitment and were included in the analysis; 49 (50.5%) of these women had endometriosis, and the 48 (49.5%) who did not have endometriosis served as a control group. During laparoscopy, tissue samples were obtained from ectopic and eutopic endometrium, and from normal pelvic peritoneum. In addition, serum samples were collected immediately before and 6-10 weeks after surgery. The mRNA levels of VCAM-1, ICAM-1 and epithelial cell adhesion molecule (EpCAM) were measured using quantitative real-time PCR, and serum protein levels of soluble VCAM-1 (sVCAM-1), ICAM-1 (sICAM-1) and EpCAM (sEpCAM) were measured using ELISA and correlated with endometriosis status. The mRNA levels of both VCAM-1 and ICAM-1 were higher in ectopic endometriotic lesions than in eutopic endometrium (P < 0.001). Moreover, the mRNA levels of both VCAM-1 and ICAM-1 were higher in normal peritoneum samples obtained from women with endometriosis compared to those from controls (P = 0.038 and P = 0.009). The mRNA levels of VCAM-1 were also higher in the eutopic endometrium samples obtained from women with endometriosis compared to controls (P = 0.018). With respect to serum protein levels, compared to controls, the women with endometriosis had lower serum levels of sICAM-1 (P = 0.042) and higher levels of sVCAM-1 (P < 0.001). Our analysis revealed that the serum levels of sVCAM-1 were not affected by lesion entity, menstrual cycle phase or disease severity. An receiver operating characteristics curve, calculated to determine whether preoperative serum sVCAM-1 concentration can be used to predict endometriosis, found an AUC of 0.868 with 80% specificity and 84% sensitivity at a cutoff value of 370 pg/ml. This predictive performance can be further improved by calculation of the sVCAM-1/sICAM-1 ratio, leading to an AUC of 0.929 with 86.7% specificity and 90.3% sensitivity at a cutoff ratio value of 1.55. Not applicable. The relatively small sample size in the expression analyses is a possible limitation of this study. Our findings could contribute to an improved understanding of the pathogenesis of endometriosis and the role of cell adhesion molecules. In addition, the results may lead to the development of new, non-invasive tools for diagnosing endometriosis. The ability to diagnose patients by measuring serum sVCAM-1 levels or the sVCAM-1/sICAM-1 ratio would have considerable clinical value. The Ingrid Flick Foundation (Grant no. FA751C0801), which played no role in the study design, data collection and analysis, decision to publish or preparation of the manuscript. The authors declare no competing interests. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Comparison of serum and plasma measurements of Müllerian inhibiting substance.
Merhi, Zaher O; Messerlian, Geralyn M; Minkoff, Howard; Eklund, Elizabeth E; Macura, Jerzy; Feldman, Joseph; Rodriguez, Carlos; Seifer, David B
2008-06-01
The authors sought to determine whether measurement of plasma Müllerian inhibiting substance (MIS) is a suitable substitute for measurement of serum MIS. Eighteen samples of serum and plasma were examined that were drawn simultaneously. Levels of MIS were measured with an ELISA kit, and plasma levels were studied in parallel to serum samples. A 98.5% correlation was found between serum and plasma MIS values.
Effect of Ramadan fasting on serum heat shock protein 70 and serum lipid profile.
Zare, A; Hajhashemi, M; Hassan, Z M; Zarrin, S; Pourpak, Z; Moin, M; Salarilak, S; Masudi, S; Shahabi, S
2011-07-01
Ramadan, the holy month for the Islamic world, is a period every year when food and fluid intake is restricted to the pre-sunrise and post-sunset hours. The aim of this study was to evaluate the effect of Ramadan fasting on the serum concentration of heat shock protein 70 (HSP70) and serum lipid profile in healthy men. A total of 32 male volunteers with a mean age of 28.5 (range 23-37) years were selected for the study. Blood samples were obtained one day prior to Ramadan and on the 3rd and 25th days of fasting. Serum HSP70, triglyceride (TG), cholesterol (Chol), low-density lipoprotein (LDL) and high-density lipoprotein (HDL), LDL/HDL and Chol/HDL ratios were investigated. It was observed that the mean concentrations of serum HSP70 and HDL on the 25th day of Ramadan were significantly higher than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels on the 3rd day of Ramadan was significantly higher than those recorded one day before Ramadan. Mean concentrations of serum TG, Chol, LDL, and LDL/HDL and Chol/HDL ratios on the 25th day of Ramadan were significantly lower than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels found on the 3rd day of Ramadan were also significantly lower than those recorded one day before Ramadan. Ramadan fasting increases serum HSP70 and improves serum lipid profile.
Zicker, F.; Smith, P. G.; Luquetti, A. O.; Oliveira, O. S.
1990-01-01
Methods used to diagnose Trypanosoma cruzi infection differ in their ability to discriminate between sera from infected and uninfected individuals. We compared the results of an immunofluorescence (IF) test, a haemagglutination (HA) test, and an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of T. cruzi infections in a large population-based survey in central Brazil using blood eluates from filter-paper and venous blood samples. The sensitivities of the tests on eluates, compared with results on serum samples, were low: ELISA (78.1%), IF (69.2%) and HA (64.6%). The level of agreement between the tests on eluates was very poor, with the best co-positivity for IF and ELISA. Both the positive and negative predictive values of the three tests on eluates were similar (around 96%) to those for sera. Higher co-positivity values were obtained for the three tests on sera. The implications of these results are discussed in relation to blood screening, routine medical practice, sero-epidemiological surveys, and the follow-up of patients admitted to therapeutic trials. PMID:2119903
Zicker, F; Smith, P G; Luquetti, A O; Oliveira, O S
1990-01-01
Methods used to diagnose Trypanosoma cruzi infection differ in their ability to discriminate between sera from infected and uninfected individuals. We compared the results of an immunofluorescence (IF) test, a haemagglutination (HA) test, and an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of T. cruzi infections in a large population-based survey in central Brazil using blood eluates from filter-paper and venous blood samples. The sensitivities of the tests on eluates, compared with results on serum samples, were low: ELISA (78.1%), IF (69.2%) and HA (64.6%). The level of agreement between the tests on eluates was very poor, with the best co-positivity for IF and ELISA. Both the positive and negative predictive values of the three tests on eluates were similar (around 96%) to those for sera. Higher co-positivity values were obtained for the three tests on sera. The implications of these results are discussed in relation to blood screening, routine medical practice, sero-epidemiological surveys, and the follow-up of patients admitted to therapeutic trials.
Serum levels of C-reactive protein in adolescents with periodontitis.
López, Rodrigo; Baelum, Vibeke; Hedegaard, Chris Juul; Bendtzen, Klaus
2011-04-01
The results of several cross-sectional studies suggested a relationship between periodontitis and higher serum levels of C-reactive protein (CRP). Most of these studies were restricted to adult study groups with severe periodontal inflammation, and the potential effects of confounding factors were frequently overlooked. A case-referent study comprised of 87 adolescent cases who presented with clinical attachment loss ≥3 mm recorded in ≥2 of 16 teeth and 73 controls who did not fulfill these criteria was nested in a fully enumerated adolescent population. Venous blood samples were obtained, and CRP levels were quantified, using a high-sensitive bead-based flow cytometric assay. The Mann-Whitney U test was used to assess overall differences between groups. The median serum CRP values for cases and controls were 64 ng/ml (interquartile range: 27 to 234 ng/ml) and 55 ng/ml (31 to 183 ng/ml), respectively (P = 0.8). Serum levels of CRP were not significantly higher among subjects with periodontitis than among controls. However, a statistically significant positive association between percentages of sites with bleeding on probing and log-transformed CRP values was observed.
Serum tenascin-C predicts severity and outcome of acute intracerebral hemorrhage.
Wang, Lin-Guo; Huangfu, Xue-Qin; Tao, Bo; Zhong, Guan-Jin; Le, Zhou-Di
2018-06-01
Tenascin-C is a matricellular protein related to brain injury. We studied serum tenascin-C in acute intracerebral hemorrhage (ICH) and examined the associations with severity and outcome following the acute event. Tenascin-C samples were obtained from 162 patients with acute hemorrhagic stroke and 162 healthy controls. Poor 90-day functional outcome was defined as modified Rankin Scale score > 2. Early neurological deterioration (END) and hematoma growth (HG) were recorded at 24 h. Patients had higher tenascin-C levels than controls. Tenascin-C levels were positively correlated with hematoma volume or National Institutes of Health Stroke Scale score at baseline. Elevated tenascin-C levels were independently associated with END, HG, 90-day mortality and poor functional outcome. Moreover, tenascin-C levels significantly predicted END, HG and 90-day outcomes under receiver operating characteristic curves. An increase in serum tenascin-C level is associated with an adverse outcome in ICH patients, supporting the potential role of serum tenascin-C as a prognostic biomarker for hemorrhagic stroke. Copyright © 2018 Elsevier B.V. All rights reserved.
Rastawicki, Waldemar; Smietafiska, Karolina; Chrost, Anna; Wolkowicz, Tomasz; Rokosz-Chudziak, Natalia
Proper analysis of the human immune response is crucial in the laboratory diagnosis of many bacterial infections-The current serological diagnosis of yersiniosis often is carried out using ELISA with native antigens. However, recombinant proteins increase the specificity of the serological assays, particularly in patients with chronic, non- specific infections. The aim of the present study was to evaluate the usefulness of in-house obtained recombinant proteins Yop of Yersinia enterocolitica as highly specific antigens in ELISA and recom-dot performed in the serodiagnosis of yersiniosis. Recombinant YopD, YopB, YopE and V-Ag proteins of Y enterocolitica were expressing in E. coli BL21 (DE3) using the pET-30 Ek/LIC expression vector (Novagen). Purification was accomplished by immobilized metal (Ni2) affinity column chromatography (His-trap). The proteins were used as antigens in standard ELISA and recom-dot assay, which was performed on nitrocellulose strips. The study population, used for characterization of the humoral immune response to the recombinant proteins, consisted of 74 patients suspected for Y enterocolitica infection and 41 clinically healthy blood donors. Some of the results obtained by ELISA and recom-dot were compared with results obtained by commercial western-blot Yersinia (Virotech). In the group of patients suspected for yersiniosis in clinical investigation the most positive results were obtained in ELISA with the recombinant protein YopD (IgA respectively 25 (42.4%), IgG 41 (69.5%), IgM 24 (40.7%). The percentage ofpositive results in the group of blood donors did not exceed 10.0% in IgG and 5.0% in IgA/IgM classes of immunoglobulin. The results obtained in the recom-dot assay showed that among 74 tested serum samples obtained from individuals suspected of yersiniosis the most common IgA, IgG and IgM antibodies were found for recombinant protein YopD (respectively IgG in 60.8%, IgA in 37.8% and IgM in 33.8% of serum samples). IgG antibodies to the protein V-Ag were observed in 32.4%, protein YopB in 27.0% and for the protein YopE in 18.9% serum samples. Immunoglobulin A, and M for the recombinant proteins were found much less frequently than IgG antibodies (respectively 12.2% and 10.8% for V protein-Ag in 10.8% and 14.9% protein and_YopB 2,7% and 10.8% for the protein YopE). Further studies showed that results obtained in recom-dot assay with recombinant protein YopD were comparable with the results of commercial western-blot Yersinia. The study showed that in-house obtained recombinant proteins can be used as highly specific antigens in ELISA and recom-dot performed in the serodiagnosis of yersiniosis. The most useful was the protein YopD.
Cardoso, Luciene C; Martins, Denise C L; Campos, Denise V B; Santos, Luciana M; Corrêa da Costa, Vânia M; Rosenthal, Doris; Vaisman, Mario; Violante, Alice H D; Carvalho, Denise P
2002-09-01
The aim of the present study was to compare the effects of iopanoic acid (IOP) or a saturated solution of potassium iodide (SSKI) administration to patients with toxic diffuse goiters (TDG). Patients with TDG are treated with thionamides and high doses of iodine preoperatively. In this study, two types of preoperative drug regimens were used: propylthiouracil or methimazole plus SSKI for 10-15 days (n=8) or IOP for 7 days (n=6). Serum thyroid hormones (total and free thyroxine (T(4)), total tri-iodothyronine (T(3)) and reverse T(3) (rT(3)), were evaluated after 7 days of either SSKI or IOP treatment, and after 10-15 days of SSKI administration. During thyroidectomy, samples of thyroid gland were obtained to evaluate thyroperoxidase and thyroid H(2)O(2)-generating activities. Serum total T(3) was significantly decreased after 7 days of either treatment, and serum rT(3) was significantly increased in IOP-treated patients. Serum total and free T(4) were unaffected by 7 days of IOP treatment, but decreased after 7 days of SSKI treatment, although significantly diminished levels were only reached after a further 3-8 days of SSKI administration. During both drug regimens, serum TSH remained low (SSKI: 0.159+/-0.122; IOP: 0.400+/-0.109 microU/ml). Thyroperoxidase activity was significantly lower in thyroid samples from patients treated with SSKI for 10-15 days than in the thyroid glands from IOP-treated patients. However, thyroid H(2)O(2) generation was inhibited in samples from patients treated with either IOP or SSKI. We show herein that IOP treatment can be effective in the management of hyperthyroidism and that this drug inhibits thyroid NADPH oxidase activity, just as previously described for SSKI, probably due to its iodine content.
Whitehead, S J; Cornes, M P; Ford, C; Gama, R
2015-01-01
Exclusion of macroprolactinaemia, a well-recognised interference, as the cause of hyperprolactinaemia is essential to avoid potential misdiagnosis and mismanagement of patients. We have derived gender-specific serum total and post-polyethylene glycol (PEG) precipitation monomeric reference ranges for the recently re-standardised Abbott Architect prolactin assay. Prolactin was measured in serum samples obtained from males (n=49) and females (n=52) using the current Abbott Architect immunoassay pre- and post-PEG precipitation. Gender-specific reference ranges were derived for total and monomeric (post-PEG) prolactin. Routine patients' samples (n=175) with a serum total prolactin >700 mIU/L were screened for macroprolactinaemia to assess classification compared with our previous post-PEG precipitation percentage recovery-based approach. Reference ranges for serum total prolactin were 58-419 mIU/L (male) and 63-561 mIU/L (female). Male and female monomeric prolactin reference ranges were 32-309 mIU/L and 39-422 mIU/L, respectively. Mean (SD) post-PEG percentage recovery of the IS 84/500 prolactin standard was 80 (2.3)%. Of 175 patients' samples screened for macroprolactinaemia, 149 had monomeric prolactin concentrations (median monomeric prolactin=1035 mIU/L; median recovery=83%) above the gender-specific reference range. Monomeric prolactin concentrations (median monomeric prolactin=162 mIU/L; median recovery=20%) in the remaining 26 were within the reference ranges. One patient classified as macroprolactin positive and another classified as macroprolactin negative would not have been identified as such using the previous recovery-based approach. The use of post-PEG monomeric reference ranges not only identifies hyperprolactinaemia due solely to macroprolactinaemia but has the added advantage of identifying patients who have simultaneous true monomeric hyperprolactinaemia and elevated concentrations of macroprolactin. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.
Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto
2017-04-01
Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Brazhnik, Kristina; Grinevich, Regina; Efimov, Anton E.; Nabiev, Igor; Sukhanova, Alyona
2014-05-01
Advanced multiplexed assays have recently become an indispensable tool for clinical diagnostics. These techniques provide simultaneous quantitative determination of multiple biomolecules in a single sample quickly and accurately. The development of multiplex suspension arrays is currently of particular interest for clinical applications. Optical encoding of microparticles is the most available and easy-to-use technique. This technology uses fluorophores incorporated into microbeads to obtain individual optical codes. Fluorophore-encoded beads can be rapidly analyzed using classical flow cytometry or microfluidic techniques. We have developed a new generation of highly sensitive and specific diagnostic systems for detection of cancer antigens in human serum samples based on microbeads encoded with fluorescent quantum dots (QDs). The designed suspension microarray system was validated for quantitative detection of (1) free and total prostate specific antigen (PSA) in the serum of patients with prostate cancer and (2) carcinoembryonic antigen (CEA) and cancer antigen 15-3 (CA 15-3) in the serum of patients with breast cancer. The serum samples from healthy donors were used as a control. The antigen detection is based on the formation of an immune complex of a specific capture antibody (Ab), a target antigen (Ag), and a detector Ab on the surface of the encoded particles. The capture Ab is bound to the polymer shell of microbeads via an adapter molecule, for example, protein A. Protein A binds a monoclonal Ab in a highly oriented manner due to specific interaction with the Fc-region of the Ab molecule. Each antigen can be recognized and detected due to a specific microbead population carrying the unique fluorescent code. 100 and 231 serum samples from patients with different stages of prostate cancer and breast cancer, respectively, and those from healthy donors were examined using the designed suspension system. The data were validated by comparing with the results of the "gold standard" enzyme-linked immunosorbent assay (ELISA). They have shown that our approach is a good alternative to the diagnostics of cancer markers using conventional assays, especially in early diagnostic applications.
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, Ksenia; Nichols, James H.
2009-01-01
Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy, anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results. PMID:20144348
Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold
2016-04-01
We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automated 25(OH)D assays (Abbott, Beckman, and Roche). The accuracy of each assay tested was evaluated against a Labquality reference serum panel for 25(OH)D (Ref!25OHD; University of Ghent). Intra- and inter-day imprecision of the Fujirebio 25(OH)D assay was <5%. Fujirebio 25(OH)D assay showed the highest correlation among the assays tested with the LC-MS/MS method (R=0.986). The mean relative bias obtained was -15.6% (Fujirebio), -12.7% (Beckman), -2.1% (Abbott) and 9.7% (Roche) as compared to LC-MS/MS. Comparison with the Labquality certified reference serum panel yielded a mean bias of -11.8% (Fujirebio), -14.1% (Beckman), 4.4% (Abbott) and 3.2% (Roche), respectively. Compared to LC-MS/MS, the sensitivity of different methods in detecting vitamin D insufficiency (<50 nmol/L) varied from 100% for the Fujirebio assay to 72.7% for Roche, and specificity ranged from 94.4% for Roche to 87.6% for Beckman. The Lumipulse G 25-OH vitamin D assay from Fujirebio demonstrated a good correlation with LC-MS/MS and some immunoassays. The performance of the assay is well-suited for routine 25(OH)D measurement in clinical serum samples. A correction for the observed negative bias vs. LC-MS/MS could be considered.
Measurement of rivaroxaban and apixaban in serum samples of patients
Harenberg, Job; Krämer, Sandra; Du, Shanshan; Zolfaghari, Shabnam; Schulze, Astrid; Krämer, Roland; Weiss, Christel; Wehling, Martin; Lip, Gregory Y H
2014-01-01
Background The determination of rivaroxaban and apixaban from serum samples of patients may be beneficial in specific clinical situations when additional blood sampling for plasma and thus the determination of factor Xa activity is not feasible or results are not plausible. Materials and methods The primary aim of this study was to compare the concentrations of rivaroxaban and apixaban in serum with those measured in plasma. Secondary aims were the performance of three different chromogenic methods and concentrations in patients on treatment with rivaroxaban 10 mg od (n = 124) or 20 mg od (n = 94) or apixaban 5 mg bid (n = 52) measured at different time. Results Concentrations of rivaroxaban and apixaban in serum were about 20–25% higher compared with plasma samples with a high correlation (r = 0·79775–0·94662) using all assays (all P < 0·0001). The intraclass correlation coefficients were about 0·90 for rivaroxaban and 0·55 for apixaban. Mean rivaroxaban concentrations were higher at 2 and 3 h compared with 1 and 12 h after administration measured from plasma and serum samples (all P-values < 0·05) and were not different between 1 vs. 12 h (plasma and serum). Conclusions The results indicate that rivaroxaban and apixaban concentrations can be determined specifically from serum samples. PMID:24931429
Plaisance, Eric P; Grandjean, Peter W; Judd, Robert L; Jones, Kathy W; Taylor, J Kyle
2009-11-01
Serum adiponectin concentrations are higher in women than men. The sexual dimorphism for adiponectin has been attributed to the direct effects of testosterone on adipose tissue adiponectin secretion. However, serum testosterone and adiponectin concentrations are generally lower in obese men than lean men, suggesting that sex steroids may not be the only factor that contributes to sex differences in serum adiponectin. The primary objective of this study was to examine the influence of sex, body composition, and nonesterified fatty acids (NEFAs) on serum adiponectin concentrations. Women and men between the ages of 18 and 35 years were consecutively accrued into the study. Sixty-one participants were partitioned into normal-weight (15 female and 16 male) or obese (14 female and 16 male) groups. Blood samples were obtained after a 12-hour fast. Differences between groups were determined by analysis of variance with Tukey-Kramer post hoc testing. Serum adiponectin was 26% higher in women compared with men. Body mass index was associated with total serum adiponectin in men (r = -0.63, P < .05) but not women. Adiponectin was correlated with the homeostasis model assessment index in women (r = -0.56, P < .05) and men (r = -0.58, P < .05) and with NEFAs (r = -0.68, P < .05) in men only. After partitioning men and women into normal-weight and obese groups, serum adiponectin was lower and NEFAs were higher in obese men only. Homeostasis model assessment was similar between obese women and men despite higher NEFAs in the obese men. Leptin and plasminogen activator inhibitor-1 were higher in obese participants but were not associated with serum NEFAs. These results suggest that serum NEFAs may reduce adiponectin concentrations independent of their effects on insulin sensitivity in obese young men.
Serological diagnosis of bovine brucellosis using B. melitensis strain B115.
Corrente, Marialaura; Desario, Costantina; Parisi, Antonio; Grandolfo, Erika; Scaltrito, Domenico; Vesco, Gesualdo; Colao, Valeriana; Buonavoglia, Domenico
2015-12-01
Bovine brucellosis is diagnosed by official tests, such as Rose Bengal plate test (RBPT) and Complement Fixation test (CFT). Both tests detect antibodies directed against the lipolysaccharide (LPS) of Brucella cell wall. Despite their good sensitivity, those tests do not discriminate between true positive and false positive serological reactions (FPSR), the latter being generated by animals infected with other Gram negative microorganisms that share components of Brucella LPS. In this study, an antigenic extract from whole Brucella melitensis B115 strain was used to set up an ELISA assay for the serological diagnosis of bovine brucellosis. A total of 148 serum samples from five different groups of animals were tested: Group A: 28 samples from two calves experimentally infected with Yersinia enterocolitica O:9; Group B: 30 samples from bovines infected with Brucella abortus; Group C: 50 samples from brucellosis-free herds; Group D: 20 samples RBPT positive and CFT negative; Group E: 20 samples both RBPT and CFT positive. Group D and Group E serum samples were from brucellosis-free herds. Positive reactions were detected only by RBPT and CFT in calves immunized with Y. enterocolitica O:9. Sera from Group B animals tested positive also in the ELISA assay, whereas sera from the remaining groups were all negative. The results obtained encourage the use of the ELISA assay to implement the serological diagnosis of brucellosis. Copyright © 2015 Elsevier B.V. All rights reserved.
Kuusela, Elina; Kouri, Vesa-Petteri; Olkkonen, Juri; Koivuniemi, Riitta; Äyräväinen, Leena; Rajamäki, Kristiina; Valleala, Heikki; Nordström, Dan; Leirisalo-Repo, Marjatta; Ainola, Mari; Eklund, Kari K
2018-03-20
To study the prevalence of asymptomatic activation of Epstein-Barr virus (EBV) in patients with rheumatoid arthritis (RA) and to analyse the correlation of serum EBV DNA with the disease activity. The level of EBV DNA was determined by droplet digital PCR assay from the serum of 46 DMARD naive early RA (ERA) and 22 chronic RA (CRA)-patients at study onset. Follow-up samples from 31 ERA and 16 CRA patients were obtained after starting or modifying the anti-rheumatic treatment. EBV DNA was also measured from 33 healthy controls and 9 patients with adult onset Still's disease (AOSD). Disease activity was assessed by the disease activity score (DAS28). At baseline, EBV DNA was detected in the serum of 7 of the 46 ERA patients all of whom had moderate or high disease activity. In the follow-up samples, 11 of 31 patients were EBV DNA positive. At baseline EBV positive patients had significantly higher disease activity (p=0.036) and the concentration of EBV DNA correlated significantly with DAS28 (rs=0.333, p=0.024). EBV DNA was detected in 3 of 22 CRA patients at study onset and in 8 of 16 in the follow-up samples. At follow-up EBV positive patients had significantly higher DAS28 (p=0.027) and the concentration of EBV DNA correlated significantly with DAS28 (rs=0.724, p=0.002). Only one of the healthy controls and none of the AOSD patients were positive for EBV DNA. Active RA is associated with a lytic EBV infection which may have a role in the pathogenesis of RA.
Vera-Candioti, Luciana; Culzoni, María J; Olivieri, Alejandro C; Goicoechea, Héctor C
2008-11-01
Drug monitoring in serum samples was performed using second-order data generated by CE-DAD, processed with a suitable chemometric strategy. Carbamazepine could be accurately quantitated in the presence of its main metabolite (carbamazepine epoxide), other therapeutic drugs (lamotrigine, phenobarbital, phenytoin, phenylephrine, ibuprofen, acetaminophen, theophylline, caffeine, acetyl salicylic acid), and additional serum endogenous components. The analytical strategy consisted of the following steps: (i) serum sample clean-up to remove matrix interferences, (ii) data pre-processing, in order to reduce the background and to correct for electrophoretic time shifts, and (iii) resolution of fully overlapped CE peaks (corresponding to carbamazepine, its metabolite, lamotrigine and unexpected serum components) by the well-known multivariate curve resolution-alternating least squares algorithm, which extracts quantitative information that can be uniquely ascribed to the analyte of interest. The analyte concentration in serum samples ranged from 2.00 to 8.00 mg/L. Mean recoveries were 102.6% (s=7.7) for binary samples, and 94.8% (s=13.5) for spiked serum samples, while CV (%)=4.0 was computed for five replicate, indicative of the acceptable accuracy and precision of the proposed method.
Floehr, Julia; Dietzel, Eileen; Neulen, Josef; Rösing, Benjamin; Weissenborn, Ute; Jahnen-Dechent, Willi
2016-03-01
Is serum fetuin-B associated with the fertilization rate in in vitro fertilization (IVF)? Serum fetuin-B increased during IVF cycles when oocytes could be fertilized while remained unchanged in fertilization failure. Fetuin-B deficiency in mice causes premature zona pellucida hardening mediated by the zona protease ovastacin. Thus fetuin-B deficiency renders females infertile. We determined the human serum fetuin-B reference range, studying longitudinally, over the course of one month, five male and seven female volunteers without hormone treatment and four female volunteers on varying hormonal contraception. We sampled blood and determined serum fetuin-B, luteinizing hormone (LH), estradiol (E2) and progesterone (P4). In addition, we determined serum fetuin-B and estradiol in eight women undergoing intracytoplasmatic sperm injection (ICSI, nine ICSI cycles) and 19 women undergoing IVF (21 IVF cycles) after ovarian stimulation with recombinant human follicular stimulating hormone (rFSH) and/or a combined medication of FSH and LH. At least three blood samples were analyzed in each cycle. We compared serum fetuin-B and follicular fluid fetuin-B in nine patients by measuring follicular fetuin-B in pooled follicular fluid, and in fluid obtained from individual follicles. Samples were drawn from January 2012 to March 2014. All volunteers and patients gave informed consent. Fetuin-B was measured employing a commercial sandwich enzyme-linked immunosorbent assay. Serum fetuin-B was determined as duplicates in 5 male (34 ± 14.6 years) and 11 female volunteers (29.4 ± 4.1 years) as well as in female volunteers on hormonal contraception (30.0 ± 6.5 years). The duplicate standard deviation was 4.0 ± 2.3%. The contraceptive drugs were mono or combined preparations containing 0-0.03 mg ethinyl estradiol, and 0.15-3.0 mg of various progestins. In addition, serum fetuin-B was determined as triplicates in 27 female patients undergoing conventional IVF (19) or ICSI (8). The triplicate standard deviation was 3.3 ± 1.8%. IVF was declared as 'successful', if at least one oocyte was fertilized, and 'unsuccessful', if no oocyte could be fertilized. Patient age was 34.4 ± 4.4 years in successful IVF, and 35.4 ± 3.3 years in unsuccessful IVF. Serum and follicular fluid of patients undergoing controlled ovarian hyperstimulation were analyzed. Serum was drawn at the day of follicle aspiration. Serum fetuin-B and follicular fluid fetuin-B were not significantly different in six out of nine patients suggesting, in principle, free exchange of fetuin-B between serum and follicular fluid. Thus serum fetuin-B may be used as a proxy of follicular fluid fetuin-B. Serum fetuin-B increased during successful IVF cycles (n = 15, P < 0.0001), but did not change in unsuccessful IVF cycles (n = 6, P = 0.118) despite increased estradiol levels (P = 0.0019 and P = 0.0254, respectively). The female volunteers self-reported their respective hormone medication. Medication was verified by serum estradiol, LH and progesterone measurements. For oocyte harvesting, the vaginal wall was punctured once only to minimize co-morbidity. Low grade cross-contamination of individual follicular fluid aspirates and contamination of the follicular fluid with small amounts of blood were inevitable. Samples were routinely checked for the presence of hemoglobin that would suggest blood contamination. Only samples containing <250 erythrocyte equivalents/µl were used for analysis. Serum fetuin-B may be used as a marker to predict the fertilization success in IVF. Fetuin-B levels attained during IVF stimulation may help to make an informed decision whether oocytes should be fertilized by IVF or by ICSI to overcome the zona pellucida as a barrier. The research was supported by a grant from Deutsche Forschungsgemeinschaft and by the START program of the Medical Faculty of RWTH Aachen University. J.F., E.D., J.N., B.R. and W.J.-D. declare that they are named inventors on the RWTH Aachen University patent application EP 13157317.2, 'Use of fetuin-B for culture of oocytes', applied for by RWTH Aachen University. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Serological evidence for the presence of influenza D virus in small ruminants.
Quast, Megan; Sreenivasan, Chithra; Sexton, Gabriel; Nedland, Hunter; Singrey, Aaron; Fawcett, Linda; Miller, Grant; Lauer, Dale; Voss, Shauna; Pollock, Stacy; Cunha, Cristina W; Christopher-Hennings, Jane; Nelson, Eric; Li, Feng
2015-11-18
Influenza D virus (FLUDV) was isolated from diseased pigs with respiratory disease symptoms in 2011, and since then the new virus has also been spread to cattle. Little is known about the susceptibility of other agricultural animals and poultry to FLUDV. This study was designed to determine if other farm animals such as goats, sheep, chickens, and turkey are possible hosts to this newly emerging influenza virus. 648 goat and sheep serum samples and 250 chicken and turkey serum samples were collected from 141 small ruminant and 25 poultry farms from different geographical locations in the United States and Canada. Serum samples were examined using the hemagglutination inhibition (HI) assay and the sheep and goat samples were further analyzed using the serum neutralization assay. Results of this study showed FLUDV antibodies were detected in 13.5% (17/126) of the sampled sheep farms, and 5.2% (29/557) of tested sheep serum samples were positive for FLUDV antibodies. For the goat results, the FLUDV antibodies were detected in 13.3% (2/15) of the sampled farms, and 8.8% (8/91) of the tested goat serum samples were positive for FLUDV antibodies. Furthermore, all tested poultry serum samples were negative for FLUDV antibodies. Our data demonstrated that sheep and goat are susceptible to FLUDV virus and multiple states in U.S. have this virus infection already in these two species. This new finding highlights a need for future surveillance of FLUDV virus in small ruminants toward better understanding both the origin and natural reservoir of this new virus. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Duarte, Janaína; Pacheco, Marcos T. T.; Villaverde, Antonio Balbin; Machado, Rosangela Z.; Zângaro, Renato A.; Silveira, Landulfo
2010-07-01
Toxoplasmosis is an important zoonosis in public health because domestic cats are the main agents responsible for the transmission of this disease in Brazil. We investigate a method for diagnosing toxoplasmosis based on Raman spectroscopy. Dispersive near-infrared Raman spectra are used to quantify anti-Toxoplasma gondii (IgG) antibodies in blood sera from domestic cats. An 830-nm laser is used for sample excitation, and a dispersive spectrometer is used to detect the Raman scattering. A serological test is performed in all serum samples by the enzyme-linked immunosorbent assay (ELISA) for validation. Raman spectra are taken from 59 blood serum samples and a quantification model is implemented based on partial least squares (PLS) to quantify the sample's serology by Raman spectra compared to the results provided by the ELISA test. Based on the serological values provided by the Raman/PLS model, diagnostic parameters such as sensitivity, specificity, accuracy, positive prediction values, and negative prediction values are calculated to discriminate negative from positive samples, obtaining 100, 80, 90, 83.3, and 100%, respectively. Raman spectroscopy, associated with the PLS, is promising as a serological assay for toxoplasmosis, enabling fast and sensitive diagnosis.
Pearce, R.D.; O'Shea, T.J.; Shankar, V.; Rupprecht, C.E.
2007-01-01
Recently, bat ectoparasites have been demonstrated to harbor pathogens of potential importance to humans. We evaluated antirabies antibody seroprevalence and the presence of ectoparasites in big brown bats (Eptesicus fuscus) sampled in 2002 and 2003 in Colorado to investigate if an association existed between ectoparasite intensity and exposure to rabies virus (RV). We used logistic regression and Akaike's Information Criteria adjusted for sample size (AICc) in a post-hoc analysis to investigate the relative importance of three ectoparasite species, as well as bat colony size, year sampled, age class, colony size, and year interaction on the presence of rabies virus neutralizing antibodies (VNA) in serum of wild E. fuscus. We obtained serum samples and ectoparasite counts from big brown bats simultaneously in 2002 and 2003. Although the presence of ectoparasites (Steatonyssus occidentalis and Spinturnix bakeri) were important in elucidating VNA seroprevalence, their intensities were higher in seronegative bats than in seropositive bats, and the presence of a third ectoparasite (Cimex pilosellus) was inconsequential. Colony size and year sampled were the most important variables in these AICc models. These findings suggest that these ectoparasites do not enhance exposure of big brown bats to RV. ?? 2007 Mary Ann Liebert, Inc.
Pietrowska, M; Marczak, L; Polanska, J; Nowicka, E; Behrent, K; Tarnawski, R; Stobiecki, M; Polanski, A; Widlak, P
2010-01-01
Mass spectrometry-based analysis of the serum proteome allows identifying multi-peptide patterns/signatures specific for blood of cancer patients, thus having high potential value for cancer diagnostics. However, because of problems with optimization and standardization of experimental and computational design, none of identified proteome patterns/signatures was approved for diagnostics in clinical practice as yet. Here we compared two methods of serum sample preparation for mass spectrometry-based proteome pattern analysis aimed to identify biomarkers that could be used in early detection of breast cancer patients. Blood samples were collected in a group of 92 patients diagnosed at early (I and II) stages of the disease before the start of therapy, and in a group of age-matched healthy controls (104 women). Serum specimens were purified and analyzed using MALDI-ToF spectrometry, either directly or after membrane filtration (50 kDa cut-off) to remove albumin and other large serum proteins. Mass spectra of the low-molecular-weight fraction (2-10 kDa) of the serum proteome were resolved using the Gaussian mixture decomposition, and identified spectral components were used to build classifiers that differentiated samples from breast cancer patients and healthy persons. Mass spectra of complete serum and membrane-filtered albumin-depleted samples have apparently different structure and peaks specific for both types of samples could be identified. The optimal classifier built for the complete serum specimens consisted of 8 spectral components, and had 81% specificity and 72% sensitivity, while that built for the membrane-filtered samples consisted of 4 components, and had 80% specificity and 81% sensitivity. We concluded that pre-processing of samples to remove albumin might be recommended before MALDI-ToF mass spectrometric analysis of the low-molecular-weight components of human serum Keywords: albumin removal; breast cancer; clinical proteomics; mass spectrometry; pattern analysis; serum proteome.
Dittmer, K E; Hinkson, J A; Dwyer, C; Adlington, B; van Andel, M
2018-01-01
To determine the prevalence of infection with Candidatus Mycoplasma haemolamae (Mhl), antibodies to bovine viral diarrhoea virus (BVDV), and BVDV antigen, and the prevalence of animals with elevated faecal nematode egg counts (FEC) in a sample of adult New Zealand alpaca (Vicugna pacos). Blood samples were obtained from 175 alpaca, collected from 15 farms around New Zealand, and from 31 samples sent to a diagnostic laboratory for routine haematology. Blood smears (n=170) were examined microscopically for the presence of haemoplasma, and DNA was extracted from whole blood (n=206) for real-time PCR testing for Mhl. Packed cell volume (PCV) was determined for 193 samples. Serum samples (n=195) were tested for BVDV antibody using ELISA, and for BVDV antigen using a real-time PCR assay. Faecal samples were collected from 143 animals; FEC were measured, and samples pooled for larval culture. No haemoplasma organisms were present on blood smear examination. Of the 206 blood samples, two (from the same farm) were positive for Mhl by real-time PCR testing, giving a prevalence of infection with Mhl of 0.97%. Of the 195 serum samples tested, four (2.1%) were positive for antibodies to BVDV; animals with BVDV antibodies were from 3/15 (20%) farms, none of which farmed cattle. None of the serum samples were positive by PCR for BVDV antigen. The median FEC was 50 epg (min 0, max 4,700), with 55/143 (38.5%) samples having 0 epg, and 33/143 (23.1%) having ≥250 epg. Haemonchus spp. were the most common nematodes present in faecal larval cultures from the North Island. Log 10 FEC was negatively associated with PCV (p=0.02), and was higher in males than females (p<0.001), and in animals that were positive compared with negative for Mhl (p=0.022). The number of alpaca infected with Mhl was low, as was the seroprevalence of BVDV. Gastrointestinal parasitism was, however, a common finding in this sample of New Zealand alpaca.
Comparison of oral fluid collection methods for the molecular detection of hepatitis B virus.
Portilho, M M; Mendonça, Acf; Marques, V A; Nabuco, L C; Villela-Nogueira, C A; Ivantes, Cap; Lewis-Ximenez, L L; Lampe, E; Villar, L M
2017-11-01
This study aims to compare the efficiency of four oral fluid collection methods (Salivette, FTA Card, spitting and DNA-Sal) to detect HBV DNA by qualitative PCR. Seventy-four individuals (32 HBV reactive and 42 with no HBV markers) donated serum and oral fluid. In-house qualitative PCR to detect HBV was used for both samples and commercial quantitative PCR for serum. HBV DNA was detected in all serum samples from HBV-infected individuals, and it was not detected in control group. HBV DNA from HBV group was detected in 17 samples collected with Salivette device, 16 samples collected by FTA Card device, 16 samples collected from spitting and 13 samples collected by DNA-Sal device. Samples that corresponded to a higher viral load in their paired serum sample could be detected using all oral fluid collection methods, but Salivette collection device yielded the largest numbers of positive samples and had a wide range of viral load that was detected. It was possible to detect HBV DNA using all devices tested, but higher number of positive samples was observed when samples were collected using Salivette device, which shows high concordance to viral load observed in the paired serum samples. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.
Kumagai, S; Koda, S; Miyakita, T; Ueno, M
2002-01-01
Objectives: To find whether or not incinerator workers employed at intermittently burning municipal incineration plants are exposed to high concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). Methods: 20 Workers employed at three municipal waste incineration plants (incinerator workers) and 20 controls were studied. The previous job, dietary, smoking, and body weight and height were obtained from a questionnaire survey. Concentrations of PCDDs and PCDFs were measured in serum samples of the workers and the deposited dust of the plants. The influence of occupational exposure on concentrations of PCDDs and PCDFs in serum samples was examined by multiple regression analysis. Results: Dust analysis showed that dominant constituents were octachlorodibenzo-p-dioxin (OCDD) and 1,2,3,4,6,7,8-heptachlorodibenzo-p-dioxin (HpCDD) among the PCDDs, and 1,2,3,4,6,7,8-heptachlorodibenzofuran (HpCDF) and octachlorodibenzofuran (OCDF) among the PCDFs. The toxicity equivalents (TEQs) of summed PCDDs and PCDFs in the deposited dust were 0.91, 33, and 11 ng TEQ/g, respectively, for plants I, II, and III. The means of TEQ in serum samples of summed PCDDs and PCDFs in the incinerator workers and controls were 22.8 and 16.4 pg TEQ/g lipid for area I, 29.4 and 19.3 pg TEQ/g lipid for area II, and 22.8 and 24.9 pg TEQ/g lipid for area III, which were almost the same as for the general population of Japan. No significant differences in the TEQ of PCDDs and TEQ of PCDDs and PCDDs were found between the incinerator workers and the controls. However, the TEQ of PCDFs was significantly higher among the incinerator workers in areas I and II, and the 1,2,3,4,6,7,8-HpCDF concentration was also significantly higher for all three areas. When the occupational exposure index for each constituent of PCDDs and PCDFs was defined as the product of the duration of employment at the incineration plant and the concentration of the constituent in the deposited dust, multiple regression analysis showed that the concentrations of HxCDF, HpCDF, and TEQ of PCDFs in serum samples increased with the occupational exposure index. The multiple regression analysis also suggested that significant factors affecting the concentrations in serum samples were area for HxCDD, age for TCDD, PeCDD, PeCDF, TEQ of PCDDs, TEQ of PCDFs, and TEQ of summed PCDDs and PCDFs, and BMI for HxCDD, HpCDD, and OCDD. Conclusion: This study showed that incinerator workers employed at intermittently burning incineration plants were not necessarily exposed to high concentrations of PCDDs and PCDFs. However, the increases in the concentrations in serum of HxCDF, HpCDF and TEQ of PCDFs with the occupational exposure index suggest that the incinerator workers had inhaled dust containing PCDDs and PCDFs during their work. PMID:12040109
Measles & rubella outbreaks in Maharashtra State, India.
Vaidya, Sunil R; Kamble, Madhukar B; Chowdhury, Deepika T; Kumbhar, Neelakshi S
2016-02-01
Under the outbreak-based measles surveillance in Maharashtra State the National Institute of Virology at Pune receives 3-5 serum samples from each outbreak and samples from the local hospitals in Pune for laboratory diagnosis. This report describes one year data on the measles and rubella serology, virus isolation and genotyping. Maharashtra State Health Agencies investigated 98 suspected outbreaks between January-December 2013 in the 20 districts. Altogether, 491 serum samples were received from 20 districts and 126 suspected cases from local hospitals. Samples were tested for the measles and rubella IgM antibodies by commercial enzyme immunoassay (EIA). To understand the diagnostic utility, a subset of serum samples (n=53) was tested by measles focus reduction neutralization test (FRNT). Further, 37 throat swabs and 32 urine specimens were tested by measles reverse transcription (RT)-PCR and positive products were sequenced. Virus isolation was performed in Vero hSLAM cells. Of the 98 suspected measles outbreaks, 61 were confirmed as measles, 12 as rubella and 21 confirmed as the mixed outbreaks. Four outbreaks remained unconfirmed. Of the 126 cases from the local hospitals, 91 were confirmed for measles and three for rubella. Overall, 93.6 per cent (383/409) confirmed measles cases were in the age group of 0-15 yr. Measles virus was detected in 18 of 38 specimens obtained from the suspected cases. Sequencing of PCR products revealed circulation of D4 (n=9) and D8 (n=9) strains. Four measles viruses (three D4 & one D8) were isolated. Altogether, 94 measles and rubella outbreaks were confirmed in 2013 in the State of Maharasthra indicating the necessity to increase measles vaccine coverage in the State.
Rosen, Jennifer B.; Doll, Margaret K.; McNall, Rebecca J.; McGrew, Marcia; Williams, Nobia; Lopareva, Elena N.; Barskey, Albert E.; Punsalang, Amado; Rota, Paul A.; Oleszko, William R.; Hickman, Carole J.; Zimmerman, Christopher M.; Bellini, William J.
2013-01-01
A mumps outbreak in upstate New York in 2009 at a summer camp for Orthodox Jewish boys spread into Orthodox Jewish communities in the Northeast, including New York City. The availability of epidemiologic information, including vaccination records and parotitis onset dates, allowed an enhanced analysis of laboratory methods for mumps testing. Serum and buccal swab samples were collected from 296 confirmed cases with onsets from September through December 2009. All samples were tested using the Centers for Disease Control and Prevention (CDC) capture IgM enzyme immunoassay (EIA) and a real-time reverse transcription-PCR (rRT-PCR) that targets the short hydrophobic gene. A subset of the samples (n = 205) was used to evaluate 3 commercial mumps IgM assays and to assess the sensitivity of using an alternative target gene (nucleoprotein) in the rRT-PCR protocol. Among 115 cases of mumps with 2 documented doses of measles, mumps, and rubella (MMR) vaccine, the CDC capture IgM EIA detected IgM in 51% of serum samples compared to 9% to 24% using three commercial IgM assays. The rRT-PCR that targeted the nucleoprotein gene increased RNA detection by 14% compared to that obtained with the original protocol. The ability to detect IgM improved when serum was collected 3 days or more after symptom onset, whereas sensitivity of RNA detection by rRT-PCR declined when buccal swabs were collected later than 2 days after onset. Selection of testing methods and timing of sample collection are important factors in the ability to confirm infection among vaccinated persons. These results reinforce the need to use virus detection assays in addition to serologic tests. PMID:23324519
Measles & rubella outbreaks in Maharashtra State, India
Vaidya, Sunil R.; Kamble, Madhukar B.; Chowdhury, Deepika T.; Kumbhar, Neelakshi S.
2016-01-01
Background & objectives: Under the outbreak-based measles surveillance in Maharashtra State the National Institute of Virology at Pune receives 3-5 serum samples from each outbreak and samples from the local hospitals in Pune for laboratory diagnosis. This report describes one year data on the measles and rubella serology, virus isolation and genotyping. Methods: Maharashtra State Health Agencies investigated 98 suspected outbreaks between January-December 2013 in the 20 districts. Altogether, 491 serum samples were received from 20 districts and 126 suspected cases from local hospitals. Samples were tested for the measles and rubella IgM antibodies by commercial enzyme immunoassay (EIA). To understand the diagnostic utility, a subset of serum samples (n=53) was tested by measles focus reduction neutralization test (FRNT). Further, 37 throat swabs and 32 urine specimens were tested by measles reverse transcription (RT)-PCR and positive products were sequenced. Virus isolation was performed in Vero hSLAM cells. Results: Of the 98 suspected measles outbreaks, 61 were confirmed as measles, 12 as rubella and 21 confirmed as the mixed outbreaks. Four outbreaks remained unconfirmed. Of the 126 cases from the local hospitals, 91 were confirmed for measles and three for rubella. Overall, 93.6 per cent (383/409) confirmed measles cases were in the age group of 0-15 yr. Measles virus was detected in 18 of 38 specimens obtained from the suspected cases. Sequencing of PCR products revealed circulation of D4 (n=9) and D8 (n=9) strains. Four measles viruses (three D4 & one D8) were isolated. Interpretation & conclusions: Altogether, 94 measles and rubella outbreaks were confirmed in 2013 in the State of Maharasthra indicating the necessity to increase measles vaccine coverage in the State. PMID:27121521
Verdugo, Cristobal; Valdes, Maria Francisca; Salgado, Miguel
2018-06-01
This study aimed to estimate the distributions of the within-herd true prevalence (TP) and the annual clinical incidence proportion (CIp) of Mycobacterium avium subsp. paratuberculosis (MAP) infection in dairy cattle herds in Chile. Forty two commercial herds with antecedents of MAP infection were randomly selected to participate in the study. In small herds (≤30 cows), serum samples were collected from all animals present. Whereas, in larger herds, milk or serum samples were collected from all milking cows with 2 or more parities. Samples were analysed using the Pourquier® ELISA PARATUBERCULOSIS (Insitute Pourquier, France) test. Moreover, a questionnaire gathering information on management practices and the frequency of clinical cases, compatible with paratuberculosis (in the previous 12 months), was applied on the sampling date. A Bayesian latent class analysis was used to obtain TP and clinical incidence posterior distributions. The model adjusts for uncertainty in test sensitivity (serum or milk) and specificity, and prior TP & CIp estimates. A total of 4963 animals were tested, with an average contribution of 124 samples per herd. A mean apparent prevalence of 6.3% (95% confidence interval: 4.0-8.0%) was observed. Model outputs indicated an overall TP posterior distribution, across herds, with a median of 13.1% (95% posterior probability interval (PPI); 3.2-38.1%). A high TP variability was observed between herds. CIp presented a posterior median of 1.1% (95% PPI; 0.2-4.6%). Model results complement information missing from previously conducted epidemiological studies in the sector, and they could be used for further assessment of the disease impact and planning of control programs. Copyright © 2018 Elsevier B.V. All rights reserved.
Comparison of Follicular and Luteal Phase Mucosal Markers of HIV Susceptibility in Healthy Women
Chandra, Neelima; Yousefieh, Nazita; Zalenskaya, Irina; Kimble, Thomas; Asin, Susana; Rollenhagen, Christiane; Anderson, Sharon M.; Herold, Betsy; Mesquita, Pedro M.M.; Richardson-Harman, Nicola; Cunningham, Tina; Schwartz, Jill L.; Doncel, Gustavo F.
2016-01-01
Abstract The purpose of this study was to evaluate differences in vaginal immune cell populations, vaginal tissue gene expression, antimicrobial activity of the cervicovaginal (CV) lavage (CVL), vaginal flora, and p24 antigen production from CV tissues after ex vivo human immunodeficiency virus (HIV) infection between follicular (FOL) and luteal (LUT) phases of the menstrual cycle. CV tissue biopsies, CV secretions, and blood samples were obtained as part of two longitudinal clinical trials of healthy women (CONRAD D11-119 and A12-124 studies). Participants (n = 39) were HIV-seronegative women not using exogenous hormone supplementation, with normal menstrual cycles, who were screened to exclude sexually transmitted and reproductive tract infections. Serum levels of estradiol and progesterone were significantly higher in the LUT versus the FOL phase of the menstrual cycle. Controlling for race, reported contraceptive use/sexual practices, and clinical trial, we found no differences in vaginal tissue immune cell populations and activation status, transcriptomes, inhibition of HIV, herpes simplex virus type 2 and Escherichia coli by the CVL, vaginal pH or Nugent score, or production of p24 antigen after ex vivo infection by HIV-1BaL between CV samples obtained in the FOL phase versus the LUT phase of the menstrual cycle. There were no significant correlations between serum estradiol and progesterone levels and CV endpoints. The hypothesis that the LUT phase of the menstrual cycle represents a more vulnerable stage for mucosal infection with HIV was not supported by data from samples obtained from the lower genital tract (ectocervix and vagina) from these two clinical trials. PMID:26750085
Cytokine profiling reveals decreased serum levels of CCL2 in active ocular toxoplasmosis.
Rey, Amanda; Molins, Blanca; Llorenç, Victor; Pelegrín, Laura; Mesquida, Marina; Adán, Alfredo
2013-10-01
Toxoplasma gondii infection is an important cause of ocular disease. Although parasite-mediated host cell lysis is probably the principal cause of tissue destruction in immunodeficiency states, hypersensitivity and inflammatory responses may underlie severe disease in otherwise immunocompetent individuals. The purpose of the current investigation was to study the cytokine profiles in serum from patients with ocular toxoplasmosis and to compare them with those obtained from healthy control subjects. Using a multiplex assay, we determined the serum concentration of granulocyte colony-stimulating factor (GCSF), interferon γ (IFNγ), interleukin (IL)-1β, IL-2, IL-6, IL-8, IL-10, chemokine (C-C motif) ligand 2 (CCL2) and tumour necrosis factor α (TNFα) in patients with inactive ocular toxoplasmosis (n=48), active ocular toxoplasmosis (n=21), and an age-matched and sex-matched healthy control group (n=25). In a subgroup of 17 patients with active disease, a second serum sample was obtained when the disease was inactive. Cytokine profiles were correlated with disease activity, severity and visual outcome. Levels of CCL2 were significantly reduced in patients with active ocular toxoplasmosis compared to the control group (564 ± 42 pg/mL vs 455 ± 35 pg/mL, p<0.05). Moreover, CCL2 levels were significantly lower during active ocular toxoplasmosis compared to inactive disease (569 ± 32 pg/mL vs 433 ± 32 pg/mL, p<0.01). GCSF and TNFα were elevated in patients with toxoplasmosis with poor visual outcome. No significant correlations were found with specific cytokine profiles and disease severity. Decreased serum levels of CCL2 may be associated with active ocular toxoplasmosis and could therefore serve as a marker of disease activity.
Kulkarni, Shilpa; Koller, Antonius; Mani, Kartik M; Wen, Ruofeng; Alfieri, Alan; Saha, Subhrajit; Wang, Jian; Patel, Purvi; Bandeira, Nuno; Guha, Chandan; Chen, Emily I
2016-11-01
Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24 and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted proteins were identified in urinary and serum exosomes. Together, these data showed the feasibility of defining biomarkers that could elucidate tissue-associated and systemic response caused by high-dose ionizing radiation. This is the first report using an exosome proteomics approach to identify radiation signatures. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kulkarni, Shilpa; Koller, Antonius; Proteomics Shared Resource, Herbert Irving Comprehensive Cancer Center, New York, New York
Purpose: Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). Methods and Materials: For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24more » and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. Results: A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Conclusions: Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted proteins were identified in urinary and serum exosomes. Together, these data showed the feasibility of defining biomarkers that could elucidate tissue-associated and systemic response caused by high-dose ionizing radiation. This is the first report using an exosome proteomics approach to identify radiation signatures.« less
Ermolenko, Yu; Anshakova, A; Osipova, N; Kamentsev, M; Maksimenko, O; Balabanyan, V; Gelperina, S
Capillary zone electrophoresis (CZE) was used for determination of rifabutin (RFB), an anti-tuberculosis antibiotic drug, in various pharmaceutical formulations. Apart from that, simultaneous determination of RFB and human serum albumin (HSA) was performed. Electrophoretic behaviour of RFB was examined at various pH levels. CE conditions: a quartz capillary tube (internal diameter 75mm, effective length 50cm, total length 60cm), the capillary temperature was 25°С, the voltage applied to the capillary tube was +20kV, the UV detection wavelength was 214nm, hydrodynamic injection of the sample was performed at 30mbar for 5s, tetraborate buffer solution (0.01М, рН9.2). The obtained results are characterized by high efficiency (number of theoretical plates up to 260,000) and sufficient sensitivity (LOQ starting from 0.02μg/ml for RFB). The obtained data are in good accord with both HPLC results (for RFB) and spectrophotometry (for HSA). Copyright © 2017 Elsevier Inc. All rights reserved.
Senolt, L; Braun, M; Olejarova, M; Forejtova, S; Gatterova, J; Pavelka, K
2005-01-01
Background: Pentosidine, an advanced glycation end product, increasingly accumulates in articular cartilage with age, and contributes to the pathogenesis of osteoarthritis (OA). Increased pentosidine concentrations are associated with inflammatory disorders—for example, rheumatoid arthritis. Objective: To compare pentosidine serum concentrations in patients with knee OA and in healthy volunteers and to determine a relationship between pentosidine and cartilage oligomeric matrix protein (COMP)—a marker of articular cartilage destruction. Methods: Paired serum and synovial fluid samples were obtained by arthrocentesis from 38 patients with knee OA and from 38 healthy volunteers. Pentosidine concentration was measured by reverse phase high performance liquid chromatography with fluorescent detection and COMP was determined by sandwich ELISA. Results: Significantly increased serum pentosidine (p<0.01) and COMP (p<0.05) levels were detected in the patients with OA compared with the control group. Serum pentosidine correlated significantly with synovial fluid pentosidine (p<0.001). Pentosidine in synovial fluid (p<0.05) and in serum (p<0.05) correlated significantly with synovial fluid COMP. Pentosidine and COMP concentrations did not correlate significantly with the radiological stage of the disease. Conclusion: Increased pentosidine serum concentration in patients with OA and its correlation with the cartilage destruction marker COMP in synovial fluid suggests that pentosidine may be important in OA pathology and is a new potential OA marker. PMID:15897309
Retinoic acid stability in stem cell cultures.
Sharow, Kyle A; Temkin, Boris; Asson-Batres, Mary Ann
2012-01-01
It has been reported that retinoids, such as retinoic acid (RA) and retinol (ROL), dissolved in aqueous solutions are susceptible to oxidative damage when exposed to light, air, and relatively high temperatures, conditions that are normal for culturing stem cells. Thus, questions arise regarding the interpretation of results obtained from studies of mouse embryonic stem cells exposed to retinoids because their isomerization state, their stability in culture conditions, and their interactions with other potential differentiation factors in growth media could influence developmental processes under study. Media samples were supplemented with retinoids and exposed to cell culture conditions with and without mouse embryonic stem cells (mESC), and retinoids were extracted and analyzed using HPLC. To determine whether retinoids are stable in media supplemented with fetal bovine serum (FBS) or in chemically-defined, serum-free media, mESC adapted to each type of growth media were investigated. Studies reported here indicate there was little loss or isomerization of at-RA, 9-cis-RA, 13-cis-RA, or ROL in cell cultures grown in serum-supplemented media when cell cultures were maintained in the dark and manipulated and observed under yellow light. In contrast, the stability of both at-RA and ROL were determined to be greatly reduced in serum-free media as compared with serum-supplemented media. Addition of 6 mg/ml bovine serum albumin was found to stabilize retinoids in serum-free media. It was also determined that ROL is less stable than RA in cell culture conditions.
Dendrimer enriched single-use aptasensor for impedimetric detection of activated protein C.
Erdem, Arzum; Congur, Gulsah
2014-05-01
A novel impedimetric aptasensor for detection of human activated protein C (APC) was introduced for the first time in the present study. An enhanced sensor response was obtained using poly(amidoamine) (PAMAM) dendrimer having 16 succinamic acid surface groups (generation 2, G2-PS), that was modified onto the surface of screen printed graphite electrode (G2-PS/SPE). An amino modified DNA aptamer was then immobilized onto the surface of G2-PS modified SPE. The selective interaction of APT with its cognate protein, APC was investigated using different electrochemical techniques; differential pulse voltammetry (DPV), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The microscopic characterization was consecutively performed before/after each modification/interaction step using scanning electron microscopy (SEM) and atomic force microscopy (AFM). The selectivity of aptasensor was tested in the presence of numerous proteins; protein C, thrombin, bovine serum albumin, factor Va and chromogenic substrate in different buffer mediums. The APC detection in the artificial serum; fetal bovine serum (FBS) was also performed impedimetrically. This dendrimer modified aptasensor technology brings several advantages: being single-use, fast screening with low-cost per measurement and resulting in sensitive detection of APC with the detection limits of 0.74 μg/mL (0.46 pmol in 35 μL sample) in buffer medium, and 2.03 μg/mL (1.27 pmol in 35 μL sample) in serum. Copyright © 2014 Elsevier B.V. All rights reserved.
Mihailovic-Vucinic, Violeta; Popevic, Ljubica; Popevic, Spasoje; Stjepanovic, Mihailo; Aleksic, Andjelka; Stanojevic-Paovic, Anka
2017-10-01
Many studies include elevated activity of angiotensin-converting enzyme (ACE) in serum in sarcoidosis and in ocular sarcoidosis as well, but there are only a few analyzing ACE activities in aqueous humor. The aim of this study is to illuminate the diagnostic value of ACE in aqueous humor in patients with ocular sarcoidosis. We analyzed twenty patients with ocular sarcoidosis and 18 patients with nonocular involvement. All patients have biopsy-positive sarcoidosis of the lungs and/or mediastinal lymph nodes. Blood samples for ACE serum levels were obtained from all patients. Aqueous humor samples were taken by paracentesis with a 25-gauge needle in local anesthesia. With appropriate statistical tests, we compared ACE activity in serum and aqueous humor in patients with and without ocular sarcoidosis. The majority of our patients with ocular sarcoidosis were female (12/20), also in the group with systemic sarcoidosis and without ocular involvement (12/6). Mean age of the whole analyzed group of sarcoidosis patients was 45 ± 6 years. There is no statistically significant difference in ACE activity in serum between two groups of patients (with and without ocular sarcoidosis). There is statistically significant difference in ACE activity in aqueous humor among patients with ocular and nonocular sarcoidosis. ACE activity in aqueous humor is significantly higher in patients with ocular sarcoidosis. Increased ACE activity in aqueous humor can point to a diagnosis of ocular sarcoidosis, without the need for ocular biopsy.
Wolfe, Barbara E.; Jimerson, David C.; Smith, Adrian; Keel, Pamela K.
2011-01-01
Objective Elevated serum amylase levels in bulimia nervosa (BN), associated with increased salivary gland size and self-induced vomiting in some patients, provide a possible marker of symptom severity. The goal of this study was to assess whether serum hyperamylasemia in BN is more closely associated with binge eating episodes involving consumption of large amounts of food or with purging behavior. Method Participants included women with BN (n=26); women with “purging disorder” (PD), a subtype of EDNOS characterized by recurrent purging in the absence of objectively large binge eating episodes (n=14); and healthy non-eating disorder female controls (n=32). There were no significant differences in age or body mass index (BMI) across groups. The clinical groups reported similar frequency of self-induced vomiting behavior and were free of psychotropic medications. Serum samples were obtained after overnight fast and were assayed for alpha-amylase by enzymatic method. Results Serum amylase levels were significantly elevated in BN (60.7 ± 25.4 international units [IU]/liter, mean ± sd) in comparison to PD (44.7 ± 17.1 IU/L, p < 02) and to Controls (49.3 ± 15.8, p < .05). Conclusion These findings provide evidence to suggest that it is recurrent binge eating involving large amounts of food, rather than self-induced vomiting, which contributes to elevated serum amylase values in BN. PMID:21781981
Liang, Si; Xu, Feng; Tang, Weibiao; Zhang, Zheng; Zhang, Wei; Liu, Lili; Wang, Junxia; Lin, Kuangfei
2016-08-01
Hair samples and paired serum samples were collected from e-waste and urban areas in Wenling of Zhejiang Province, China. The PBDE and DBDPE concentrations in hair and serum samples from e-waste workers were significantly higher than those of non-occupational residents and urban residents. BDE209 was the dominating BFRs in hair and serum samples from the e-waste area, while DBDPE was the major BFRs from the urban area. Statistically significant correlations were observed between hair level and serum level for some substances (BDE209, DBDPE, BDE99, BDE47, BDE28, and BDE17), although the PBDE congener profiles in hair were different from those in the serum. A statistically significant positive correlation between the PBDE concentrations and the working age, as well as gender difference, was observed in e-waste workers. Different sources of PBDEs and DBDPE in three groups were identified by principal component analysis and spearman correlation coefficient. Hair is suggested to be a useful matrix for biomonitoring the PBDE exposure in humans.
Litwiniuk, Małgorzata; Niemczyk, Kazimierz; Niderla-Bielińska, Justyna; Łukawska-Popieluch, Izabela; Grzela, Tomasz
2017-10-01
To assess the expression of endoglin in head and neck paragangliomas and the soluble endoglin level in serum of paraganglioma patients. Seven tumor samples of patients operated for cervical paraganglioma were assessed, as well as serum samples collected preoperatively, on days 4 and 28 postoperation. Serum level of endoglin in healthy controls was also determined. Tumor samples were subjected to immunofluorescent staining and examined with confocal microscope. The level of soluble endoglin in serum samples was examined using the immunoenzymatic assay (ELISA). Endoglin was highly expressed in all tumor samples. The level of soluble endoglin was significantly higher in paraganglioma patients compared to healthy controls and correlated with the tumor size. The serum level of s-endoglin was reduced after surgical excision of the tumor and remained stable after 4 weeks in all patients with complete resection of the tumor. Endoglin is an important factor in the pathophysiology of head and neck paragangliomas and may be a potential diagnostic and prognostic marker in these types of tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyle, Jennifer E.; Casey, Cameron P.; Stratton, Kelly G.
The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules weremore » identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.« less
FTIR study of secondary structure of bovine serum albumin and ovalbumin
NASA Astrophysics Data System (ADS)
Abrosimova, K. V.; Shulenina, O. V.; Paston, S. V.
2016-11-01
Proteins structure is the critical factor for their functioning. Fourier transform infrared spectroscopy provides a possibility to obtain information about secondary structure of proteins in different states and also in a whole biological samples. Infrared spectra of egg white from the untreated and hard-boiled hen's egg, and also of chicken ovalbumin and bovine serum albumin in lyophilic form and in aqueous solution were studied. Lyophilization of investigated globular proteins is accompanied by the decrease of a-helix structures and the increase in amount of intermolecular β-sheets. Analysis of infrared spectrum of egg white allowed to make an estimation of OVA secondary structure and to observe α-to-β structural transformation as a result of the heat denaturation.
Ebrahimpour, Anahita; Vaghari-Tabari, Mostafa; Qujeq, Durdi; Moein, Soheila; Moazezi, Zoleikha
2018-05-05
Subclinical hypothyroidism known as mild thyroid disorder without significant sign and symptoms. The correlation between subclinical hypothyroidism and some of cardiovascular disease risk factors such as serum lipids, homocysteine levels and also insulin resistance index is not well established and the current study was conducted to clarify this issue. Seventy four patients with mild elevation in levels of thyroid stimulating hormone (TSH) along with normal levels of T3 and T4 were selected as patients group and 74 age and sex matched individuals were selected as healthy control group. Serum insulin, triglyceride, glucose, total cholesterol, LDL-cholesterol, HDL-cholesterol and homocysteine levels were measured. Obtained data compared between groups with independent sample t-test. For evaluation of the correlation between mentioned parameters Pearson correlation coefficient method was used. Serum levels of LDL-C and total cholesterol significantly increased in SCH group compared to healthy control group. Homeostatic Model Assessment of Insulin Resistance (HOM-IR) and serum homocysteine level significantly elevated in patients with SCH compared to control group. There was a significant direct correlation between HOM-IR and serum homocysteine levels in SCH patients. Subclinical hypothyroidism likely have significant effect on insulin resistance as major diabetes risk factors and also cardiovascular disease risk factors such as homocysteine. The direct correlation between HOM-IR with serum homocysteine level indicate the possible role of insulin resistance in elevation of serum homocysteine in SCH patient group. Copyright © 2018 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Ozone Exposure Increases Circulating Stress Hormones and Lipid Metabolites in Humans
Miller, Desinia B.; Ghio, Andrew J.; Karoly, Edward D.; Bell, Lauren N.; Snow, Samantha J.; Madden, Michael C.; Soukup, Joleen; Cascio, Wayne E.; Gilmour, M. Ian
2016-01-01
Rationale: Air pollution has been associated with increased prevalence of type 2 diabetes; however, the mechanisms remain unknown. We have shown that acute ozone exposure in rats induces release of stress hormones, hyperglycemia, leptinemia, and glucose intolerance that are associated with global changes in peripheral glucose, lipid, and amino acid metabolism. Objectives: To examine ozone-induced metabolic derangement in humans using serum metabolomic assessment, establish human-to-rodent coherence, and identify novel nonprotein biomarkers. Methods: Serum samples were obtained from a crossover clinical study that included two clinic visits (n = 24 each) where each subject was blindly exposed in the morning to either filtered air or 0.3 parts per million ozone for 2 hours during 15-minute on-off exercise. Serum samples collected within 1 hour after exposure were assessed for changes in metabolites using a metabolomic approach. Measurements and Main Results: Metabolomic analysis revealed that ozone exposure markedly increased serum cortisol and corticosterone together with increases in monoacylglycerol, glycerol, and medium- and long-chain free fatty acids, reflective of lipid mobilization and catabolism. Additionally, ozone exposure increased serum lysolipids, potentially originating from membrane lipid breakdown. Ozone exposure also increased circulating mitochondrial β-oxidation–derived metabolites, such as acylcarnitines, together with increases in the ketone body 3-hydroxybutyrate. These changes suggested saturation of β-oxidation by ozone in exercising humans. Conclusions: As in rodents, acute ozone exposure increased stress hormones and globally altered peripheral lipid metabolism in humans, likely through activation of a neurohormonally mediated stress response pathway. The metabolomic assessment revealed new biomarkers and allowed for establishment of rodent-to-human coherence. Clinical trial registered with www.clinicaltrials.gov (NCT 01492517). PMID:26745856
Skrzydlewska, Elzbieta; Sulkowska, Mariola; Wincewicz, Andrzej; Koda, Mariusz; Sulkowski, Stanislaw
2005-01-01
AIM: Proteolytic degradation of the extracellular matrix facilitates cancer invasion and promotes metastasis. The study aims at evaluation of preoperative and postoperative serum cathepsins B and D levels in correlation with selected anatomoclinical features of colorectal cancer. METHODS: Blood samples were collected from 63 colorectal cancer patients before curative operation of the tumor 10 d later. Blood that was obtained from 20 healthy volunteers, served as a control. The activity of cathepsin B was measured with Bz-DL-arginine-pNA as a substrate at pH 6.0, while cathepsin D activity was determined with urea-denatured hemoglobin (pH 4.0). RESULTS: The preoperative and postoperative activities of cathepsin B were significantly (P < 0.00001) lower in serum of colorectal cancer patients than in control group. However, postoperative values of this protease were significantly increased in comparison with preoperative ones (P = 0.031). Activity of cathepsin D appeared to be significantly higher in colorectal cancer sera (P < 0.00001) compared with controls. No statistically significant differences between preoperative and postoperative activity of cathepsin D were noted (P = 0.09). We revealed a strong linkage of cathepsins’ levels with lymph node status and pT stage of colorectal cancer. CONCLUSION: Blood serum activities of cathepsin B and D depend on the time of sampling, tumor size and lymph node involvement. Significantly, increased activity of cathepsin D could indicate a malignant condition of the large intestine. In our work, the serum postoperative decrease of cathepsin B activity appears as an obvious concomitant of local lymph node metastasis-the well-known clinicopathological feature of poor prognosis. PMID:16015694
Piccione, G; Alberghina, D; Marafioti, S; Giannetto, C; Casella, S; Assenza, A; Fazio, F
2012-08-01
The aim of this study was to evaluate the influence of different physiological phases on serum total proteins and their fractions of ten Comisana ewes housed in Mediterranean area. From each animal, blood samples were collected at different physiological phases: late pregnancy, post-partum, early, mid-, end lactation and dry period. On all samples serum total proteins were determined by the biuret method, and albumin, α-globulins, β(1) -globulins, β(2) -globulins and γ-globulins concentrations were assessed using an automated system. One-way repeated measures analysis of variance was applied to determine the significant effect of different physiological phases on the parameters studied. During the late pregnancy and post-partum, total proteins, β1- and β2-globulins and γ-globulins showed the highest values. Starting from post-partum, α-globulins increased to reach their peaks in mid-lactation. Early lactation was characterized by low γ-globulins values. The increase in serum albumin concentration and the drop in some globulin fractions determined the significant increase in albumin/globulin ratio. The obtained results contributed to improve the knowledge on electrophoretic profile during the different physiological phases in ewes, confirming that pregnancy and lactation periods affect the protein metabolism. Particularly, serum protein fractions pattern could give information about dehydration, plasma volume expansion and hepatic function, which occur during the different physiological phases. Dynamics of the protein profile - from pregnancy to dry period - which are provided by our results, could be considered as guidelines for the management strategies to guarantee the nutritional needs of these animals during the different physiological phases and to avoid a decline of productive performance and consequently an economic loss. © 2011 Blackwell Verlag GmbH.
Heijnen, M L; van Amelsvoort, J M; Deurenberg, P; Beynen, A C
1996-09-01
The question addressed was whether dietary resistant starch would lower serum cholesterol and triacylglycerol concentrations in healthy normolipidemic subjects. In a randomized single-blind 3 x 3 Latin-square study with corrections for any carryover effects, 27 males and 30 females consumed supplements containing glucose or resistant starch (RS) from raw high-amylose cornstarch (RS2) or from retrograded high-amylose cornstarch (RS3). The RS2 and RS3 supplements provided 30 g RS/d. Each type of supplement was consumed in addition to the habitual diet for 3 wk. At the end of each 3-wk period, fasting blood samples and a 24-h food-consumption recall were obtained from each subject. The subjects collected 24-h urine samples for lithium determination, which was added to the supplements to check compliance. Mean lithium recovery was 97% and did not differ between supplements. The mean composition of the background diet was similar when the three supplements were taken. Body weight remained constant throughout the study. There were no significant differences in the fasting concentrations of serum total, high-density-lipoprotein (HDL), and low-density-lipoprotein (LDL) cholesterol; triacylglycerols, or 3 alpha-hydroxy bile acids after consumption of glucose, RS2, or RS3. Evidence is presented that the lack of effect of RS2 and RS3 on serum lipid concentrations cannot be explained by insufficient statistical power, a low dose, or a short duration of treatment. The subjects reported softer stools and more gastrointestinal symptoms after supplementation with RS than after glucose. Neither the RS2 nor the RS3 supplements lowered serum lipid concentrations in healthy, normolipidemic men and women.
Alkerwi, Ala'a; Sauvageot, Nicolas; Crichton, Georgina E; Elias, Merrill F; Stranges, Saverio
2016-05-01
This study examined the association of chocolate consumption with insulin resistance and serum liver enzymes in a national sample of adults in Luxembourg. A random sample of 1153 individuals, aged 18-69 years, was recruited to participate in the cross-sectional Observation of Cardiovascular Risk Factors in Luxembourg study. Chocolate consumption (g/d) was obtained from a semi-quantitative FFQ. Blood glucose and insulin levels were used for the homoeostasis model assessment of insulin resistance (HOMA-IR). Hepatic biomarkers such as serum γ-glutamyl-transpeptidase (γ-GT), serum aspartate transaminase and serum alanine transaminase (ALT) (mg/l) were assessed using standard laboratory assays. Chocolate consumers (81·8 %) were more likely to be younger, physically active, affluent people with higher education levels and fewer chronic co-morbidities. After excluding subjects taking antidiabetic medications, higher chocolate consumption was associated with lower HOMA-IR (β=-0·16, P=0·004), serum insulin levels (β=-0·16, P=0·003) and γ-GT (β=-0·12, P=0·009) and ALT (β=-0·09, P=0·004), after adjustment for age, sex, education, lifestyle and dietary confounding factors, including intakes of fruits and vegetables, alcohol, polyphenol-rich coffee and tea. This study reports an independent inverse relationship between daily chocolate consumption and levels of insulin, HOMA-IR and liver enzymes in adults, suggesting that chocolate consumption may improve liver enzymes and protect against insulin resistance, a well-established risk factor for cardiometabolic disorders. Further observational prospective research and well-designed randomised-controlled studies are needed to confirm this cross-sectional relationship and to comprehend the role and mechanisms that different types of chocolate may play in insulin resistance and cardiometabolic disorders.
Amorim, Mayra Z; Machado, Marco; Hackney, Anthony C; de Oliveira, Wilkes; Luz, Carla Patrícia Novais; Pereira, Rafael
2014-01-01
We investigated differences in sex responses in serum CK activity and renal function measured by glomerular filtration rate (GFR) after an exercise session. Twenty-two healthy and trained volunteers (11 males and 11 females) performed 17 resistance exercises with 3 × 12 repetitions in a circuit training fashion. Subjects provided blood samples prior to exercise session, and at 24, 48, and 72 h following exercise sessions for creatine kinase and creatinine. Twenty-four-hour urine samples were collected before and 72 h after the exercise. Estimate (e) GFR was obtained by using the Chronic Kidney Disease Epidemiology Collaboration equation adjusted for males and females. After the exercise session, males showed greater serum CK activity than females (p < 0.02), serum creatinine increased 31.3 % for males and 29.8 % for females, and urinary creatinine decreased on average 5.4 % for males and 0.6 % for females, with no significant differences (p > 0.05) between sex for serum and urinary creatinine. eGFR decreased significantly for males (~10 %) and females (~8 %), but also without a difference between the sexes (p > 0.05). The correlation between CK and eGFR was significant for males (r = -0.794; p = 0.003), and females (r = -0.8875; p < 0.001). A significant negative correlation between CK activity and the eGFR indice of renal function in both males and females was observed. Additionally, the renal function compromise was similar for both sexes, despite males presenting greater exercise-induced skeletal muscle damage when compared to females.
Maki, Katsuyuki; Watabe, Etsuko; Iguchi, Yumi; Nakamura, Hideko; Tomishima, Masaki; Ohki, Hidenori; Yamada, Akira; Matsumoto, Satoru; Ikeda, Fumiaki; Tawara, Shuichi; Mutoh, Seitaro
2006-01-01
To establish an in vitro method of predicting in vivo efficacy of antifungal drugs against Candida albicans and Aspergillus fumigatus, the antifungal activities of fluconazole, itraconazole, and amphotericin B were determined in mouse serum. The minimum inhibitory concentration (MIC) of each drug was measured using mouse serum as a diluent. For C. albicans, the assay endpoint of azoles was defined as inhibition of mycelial extension (mMIC) and for A. fumigatus, as no growth (MIC). The MICs of amphotericin B for both pathogens were defined as the MIC at which no mycelial growth occurred. Serum MIC or mMIC determinations were then used to estimate the concentration of the drugs in serum of mice treated with antifungal drugs by multiplying the antifungal titer of the serum samples by the serum (m)MIC. The serum drug concentrations were also determined by HPLC. The serum concentrations estimated microbiologically showed good agreement with those determined by HPLC, except for itraconazole. Analysis of the serum samples from itraconazole-treated mice by a sensitive bioautography revealed the presence of additional spots, not seen in control samples of itraconazole. The bioautography assay demonstrated that the additional material detected in serum from mice treated with itraconazole was an active metabolite of itraconazole. The data showed that the apparent reduction in the itraconazole serum concentration as determined by HPLC was the result of the formation of an active metabolite, and that the use of a microbiological method to measure serum concentrations of drugs can provide a method for prediction of in vivo efficacy of antifungal drugs.
Yao, Hanchun; Zhang, Min; Zeng, Wenyuan; Zeng, Xiaoying; Zhang, Zhenzhong
2014-05-01
A rapid and sensitive flow injection chemiluminescence (FI-CL) method is described for the determination of 2-methoxyestradiol (2ME) based on enhancement of the CL intensity from a potassium ferricyanide-calcein system in sodium hydroxide medium. The optimum conditions for the CL emission were investigated. Under optimized conditions, a linear calibration graph was obtained over the range 1.0 × 10(-8) to 1.0 × 10(-6) mol/L (r = 0.998) 2ME with a detection limit (3σ) of 5.4 × 10(-9) mol/L. The relative standard deviation (RSD) for 5.0 × 10(-7) mol/L 2ME was 1.7%. As a preliminary application, the proposed method was successfully applied to the determination of 2ME in injection solutions and serum samples. The possible CL mechanism was also proposed. Copyright © 2013 John Wiley & Sons, Ltd.
Vilar, M J; Ranta, J; Virtanen, S; Korkeala, H
2015-01-01
Bayesian analysis was used to estimate the pig's and herd's true prevalence of enteropathogenic Yersinia in serum samples collected from Finnish pig farms. The sensitivity and specificity of the diagnostic test were also estimated for the commercially available ELISA which is used for antibody detection against enteropathogenic Yersinia. The Bayesian analysis was performed in two steps; the first step estimated the prior true prevalence of enteropathogenic Yersinia with data obtained from a systematic review of the literature. In the second step, data of the apparent prevalence (cross-sectional study data), prior true prevalence (first step), and estimated sensitivity and specificity of the diagnostic methods were used for building the Bayesian model. The true prevalence of Yersinia in slaughter-age pigs was 67.5% (95% PI 63.2-70.9). The true prevalence of Yersinia in sows was 74.0% (95% PI 57.3-82.4). The estimates of sensitivity and specificity values of the ELISA were 79.5% and 96.9%.
Barnett, Jacqueline M.; Wraith, Patrick; Kiely, Janice; Persad, Raj; Hurley, Katrina; Hawkins, Peter; Luxton, Richard
2014-01-01
We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM) to quantify paramagnetic particles (PMPs) in immunochromatographic (lateral flow) assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA) in serum samples. A detection limit of 0.8 ng/mL was achieved for total PSA using the RCM and is at clinically significant concentrations. Comparison of data obtained in a pilot study from the analysis of serum samples with commercially available immunoassays shows good agreement. The development of a quantitative magneto-immunoassay in lateral flow format for total PSA suggests the potential of the RCM to operate with many immunoassay formats. The RCM has the potential to be modified to quantify multiple analytes in this format. This research shows promise for the development of an inexpensive device capable of quantifying multiple analytes at the point-of-care using a magneto-immunoassay in lateral flow format. PMID:25587419
SEPARATION AND CHARACTERIZATION OF HUMAN SERUM CHYLOMICRONS
Scanu, Angelo; Page, Irvine H.
1959-01-01
Chylomicrons were separated by low and high speed ultracentrifugation from lipemic sera of human subjects in the absorptive phase. The final chylomicron preparation was free from other serum components and contained a small constant amount of protein, approximately 2 per cent of the chylomicron fraction. Electrophoresis, immunochemical analysis, and absorption experiments identified the protein component as derived from a mixture of beta and alpha1 serum lipoproteins. Large aliquots of an emulsion of serum freed of chylomicrons and coconut oil were incubated at 37°C. for 2 hours and ultracentrifuged as in the preparation of chylomicrons. The fat particles now showed the presence of minute amounts of beta and alpha1 serum lipoproteins in almost the same proportion as found in chylomicrons. "Finger prints" of delipidized samples of chylomicrons and particles from serum-coconut oil emulsion gave similar, although not identical patterns. The data on "clearing factor" activity corroborated the finding that serum alpha1 lipoproteins are contained in chylomicrons and particles from serum-coconut oil emulsion. These two lipide particles, partially delipidized, were both able to activate a "clearing factor" system in vitro, a property exhibited only by intact or partially delipidized alpha1 serum lipoproteins. Clearing activity was satisfactorily determined by using an emulsion of coconut oil mixed in agar as a substrate to give an opaque gel, in which the diffusing enzyme showed its activity by areas of clearing. The results obtained by this technique were in agreement with those based on fall in optical density and non-esterified fatty acid production. Chemical analysis of serum chylomicrons showed a concentration of cholesterol and phospholipides higher than could be accounted for by the attached beta and alpha1 serum lipoproteins. On the basis of these results the assumption is made that in the blood stream small amounts of serum lipoproteins, by a process of adsorption, form a complex with the absorbed triglycerides, cholesterol, and phospholipides, to produce chylomicrons. PMID:13620852
Chrzczanowicz, Jacek; Gawron, Anna; Zwolinska, Anna; de Graft-Johnson, Jeffrey; Krajewski, Wojciech; Krol, Maciej; Markowski, Jaroslaw; Kostka, Tomasz; Nowak, Dariusz
2008-01-01
2,2-Diphenyl-1-picryl-hydrazyl (DPPH) radical decomposition in alcohol solution is widely used, characterizing plant antioxidants that can rise in serum after fruit and vegetable intake. However, this test failed reproducible results with serum due to protein precipitation. We describe the application of serum deproteinization with acetonitrile relating to the DPPH test. Assay sensitivity, linearity, repeatability and storage effect were determined in serum samples deproteinized with an equal volume of acetonitrile. Associations between the DPPH test and the ferric reducing ability of serum (FRAP) method, measuring total antioxidant potential, were evaluated in sera from 78 healthy non-smoking men. The effect of a single ingestion of 1 L of cloudy apple juice on the serum DPPH radical scavenging activity in healthy volunteers was also investigated. Assay linearity was within 5-25 microL (r=0.99, p<0.01). With 25 microL-deproteinized serum, coefficient of variation was 4.2% and detection limit was 0.5% of the initial amount of decomposed DPPH radical over 30 min incubation. There was no sera activity decrease over 14 days storage at -20 degrees C. Mean values of DPPH radical scavenging activity and FRAP obtained in human serum were 11.2+/-3.3% and 382.0+/-88.1 micromol/L, respectively. A positive significant linear correlation was observed between these two methods (r=0.42, p<0.01). Serum supplementation with 50 micromol/L of catechin, gallic acid, ascorbic acid or uric acid enhanced DPPH test results. One brisk serving of 1 L of apple juice caused a significant increment of serum DPPH radical scavenging activity (1.9+/-1.9%, p<0.01) in 12 healthy subjects 1 h after juice ingestion. Applicability of the DPPH test to deproteinized serum with acetonitrile revealed numerous advantages, validating its practicability, simplicity and cost effectiveness as a tool in the estimation of antioxidant status in humans.
A gas chromatography-mass spectrometry assay to quantify camphor extracted from goat serum.
Lee, Kyung-Min; Dai, Susie Y; Herrman, Timothy J; Musser, Jeffrey M B
2012-09-15
A sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for quantification and pharmacokinetics of camphor, a major monoterpene of juniper plant, in goat serum. Camphor and internal standard (terpinolene) eluates from solid phase extraction (SPE) with ethyl acetate yielded well resolved peaks and were clearly identified in total and selected ion chromatograms. The elution and injection volumes were optimized for improved detection and quantification of camphor based on peak shape, signal to noise ratio, recoveries, and repeatability. The matrix calibration curve with the good linearity (R(2)=0.998) and response in the range of 0.005-10.0 μg/mL was used to determine camphor concentration in goat serum. The GC-MS method offered sufficiently low limits of detection (1 ng/mL) and quantitation (3 ng/mL) for camphor concentration in goat serum for the pharmacokinetic study. The proposed method showed good intra- and inter-day variation with relative standard deviation (RSD) of 0.2-7.7% and produced good recovery (96.0-111.6%) and reproducibility (1.6-6.1%) at all spiked levels. Using this method on serum samples obtained from two goats orally dosed with camphor confirmed that the method is suitable for camphor studies in animals. Copyright © 2012 Elsevier B.V. All rights reserved.
Park, Wook Ha; Kang, Sora; Lee, Hong Kyu; Salihovic, Samira; Bavel, Bert van; Lind, P Monica; Pak, Youngmi Kim; Lind, Lars
2017-08-24
Metabolic syndrome and mitochondrial dysfunction have been linked to elevated serum levels of persistent organic pollutants (POPs). However, it is not clear which specific POPs contribute to aryl hydrocarbon receptor (AhR)-dependent bioactivity or inhibit mitochondrial function in human subjects. Here, we measured the cumulative bioactivity of AhR ligand mixture (AhR bioactivity) and the effects on mitochondrial function (ATP concentration) in recombinant Hepa1c1c7 cells incubated with raw serum samples obtained from 911 elderly subjects in the Prospective Investigation of the Vasculature in Uppsala Seniors (PIVUS) cohort. Plasma concentrations of 30 POPs and plastic chemicals have previously been determined in the same PIVUS subjects. Linear regression analysis demonstrated that total toxic equivalence (TEQ) values and polychlorinated biphenyls (PCBs) were significantly correlated with AhR bioactivity (positively) and ATP concentration (negatively). Serum AhR bioactivities were positively associated with some PCBs, regardless of their dioxin-like properties, but only dioxin-like PCBs stimulated AhR bioactivity. By contrast, PCBs mediated a reduction in ATP content independently of their dioxin-like properties. This study suggests that AhR bioactivity and ATP concentrations in serum-treated cells may be valuable surrogate biomarkers of POP exposure and could be useful for the estimation of the effects of POPs on human health.
Weiss, D J; Geor, R J; Burger, K
1996-06-01
To determine whether furosemide treatment altered the blood flow properties and serum and RBC electrolyte concentrations of Thoroughbreds during submaximal treadmill exercise. Thoroughbreds were subjected to submaximal treadmill exercise with and without treatment with furosemide (1 mg/kg of body weight, IV). 5 healthy Throughbreds that had raced within the past year and had no history of exercise-induced pulmonary hemorrhage. Venous blood samples were obtained before exercise, at treadmill speeds of 9 and 13 m/s, and 10 minutes after exercise, and hemorheologic and electrolyte test results were determined. Hemorheologic changes 60 minutes after furosemide administration included increased PCV, plasma total protein concentration, whole blood viscosity, mean RBC volume, and RBC potassium concentration, and decreased serum potassium concentration, serum chloride concentration, and RBC chloride concentration. Furosemide treatment attenuated the exercise-associated changes in RBC size, serum sodium concentration, serum potassium concentration, RBC potassium and chloride concentrations, and RBC density; exacerbated exercise-associated increases in whole blood viscosity; and had no effect on RBC filterability. The hemorheologic effects of furosemide probably occurred secondary to total body and transmembrane fluid and electrolyte fluxes and would not improve blood flow properties. The beneficial effects of furosemide treatment in reducing the severity of bleeding in horses with exercise-induced pulmonary hemorrhage cannot be explained by improved blood flow properties.
Davies, R H; Heath, P J; Coxon, S M; Sayers, A R
2003-01-01
Monitoring for Salmonella in slaughter pigs is important to enable targeted control measures to be applied on problem farms and at the abattoir. The aim of this study was to determine whether pooled serum and meat juice could be used to identify finishing pig herds with a high prevalence of infection. Samples of meat juice, serum, caecal contents, carcase swabs and pooled faeces from pig pens were taken from 20 commercial pig finishing farms and comparisons were made between the results of Salmonella culture, individual ELISA tests on serum and meat juice and pooled samples of serum and meat juice. Salmonella was isolated from samples from 19 of 20 farms. None of the ELISA tests showed a statistically significant correlation with caecal carriage of Salmonella or contamination of carcases. Serum mean optical density (O.D.) from pools of five, 10 or 20 sera showed a significant correlation with the Salmonella status of farm pen faeces. All pooled serum O.D. and sample/positive control ratio results correlated significantly with the results of the conventional individual sample ELISA. There was a statistically significant correlation between the incidence of Salmonella in farm pen pooled faeces and the prevalence of Salmonella in caeca of slaughter pigs. The results show a generally poor correlation between serological and bacteriological results but pooled serum or meat juice samples could be used as a cheaper substitute for serological screening of farms for Salmonella than individual samples. The availability of a cheaper test should allow the costs of Salmonella monitoring of pig farms to be reduced or allow more regular testing to enhance the designation of farm Salmonella risk status.
Lim, Yen Ying; Rainey-Smith, Stephanie; Lim, Yoon; Laws, Simon M; Gupta, Veer; Porter, Tenielle; Bourgeat, Pierrick; Ames, David; Fowler, Christopher; Salvado, Olivier; Villemagne, Victor L; Rowe, Christopher C; Masters, Colin L; Zhou, Xin Fu; Martins, Ralph N; Maruff, Paul
2017-11-01
The brain-derived neurotrophic factor (BDNF) Val66Met polymorphism Met allele exacerbates amyloid (Aβ) related decline in episodic memory (EM) and hippocampal volume (HV) over 36-54 months in preclinical Alzheimer's disease (AD). However, the extent to which Aβ+ and BDNF Val66Met is related to circulating markers of BDNF (e.g. serum) is unknown. We aimed to determine the effect of Aβ and the BDNF Val66Met polymorphism on levels of serum mBDNF, EM, and HV at baseline and over 18-months. Non-demented older adults (n = 446) underwent Aβ neuroimaging and BDNF Val66Met genotyping. EM and HV were assessed at baseline and 18 months later. Fasted blood samples were obtained from each participant at baseline and at 18-month follow-up. Aβ PET neuroimaging was used to classify participants as Aβ- or Aβ+. At baseline, Aβ+ adults showed worse EM impairment and lower serum mBDNF levels relative to Aβ- adults. BDNF Val66Met polymorphism did not affect serum mBDNF, EM, or HV at baseline. When considered over 18-months, compared to Aβ- Val homozygotes, Aβ+ Val homozygotes showed significant decline in EM and HV but not serum mBDNF. Similarly, compared to Aβ+ Val homozygotes, Aβ+ Met carriers showed significant decline in EM and HV over 18-months but showed no change in serum mBDNF. While allelic variation in BDNF Val66Met may influence Aβ+ related neurodegeneration and memory loss over the short term, this is not related to serum mBDNF. Longer follow-up intervals may be required to further determine any relationships between serum mBDNF, EM, and HV in preclinical AD.
Fonfara, Sonja; Sundermeyer, Janne; Casamian Sorrosal, Domingo; Weber, Corinna; Rosenberger, Tanja
2016-12-15
OBJECTIVE To measure serum cardiac troponin I (cTnI) concentrations in orphaned harbor seal (Phoca vitulina) pups at various points during rehabilitation in a seal rescue center and determine whether cTnI concentration was associated with survival during rehabilitation and duration of rehabilitation. DESIGN Serial cross-sectional study. ANIMALS Fifty-five 2- to 9-day-old harbor seal pups. PROCEDURES Blood samples for serum cTnI concentration measurement, CBC, and serum biochemical analysis were obtained from seal pups at admission into a seal rescue center, after 2 weeks of rehabilitation at the center, and prior to release. Serum cTnI concentrations were compared between seals that did or did not survive rehabilitation. RESULTS Median serum cTnI concentration was highest at admission (0.03 ng/mL). After 2 weeks, the median value was 0.01 ng/mL; prior to release, it was 0.01 ng/mL. Seal pups that were found to have died during or after rehabilitation (n = 7) had a significantly higher median serum cTnI concentration at admission (0.06 ng/mL) than did seal pups that survived rehabilitation (and for which the postrelease fate was unknown; 48; 0.03 ng/mL). No correlation was identified between serum cTnI concentration and duration of rehabilitation. CONCLUSIONS AND CLINICAL RELEVANCE The results of this study suggested some degree of myocardial injury was present in most of the orphaned seal pups admitted for rehabilitation. Measurement of serum cTnI concentration in seal pups at admission might provide prognostic information about their likelihood of survival during or after rehabilitation.
Detection of Serum microRNAs From Department of Defense Serum Repository
Woeller, Collynn F.; Thatcher, Thomas H.; Van Twisk, Daniel; Pollock, Stephen J.; Croasdell, Amanda; Kim, Nina; Hopke, Philip K.; Xia, Xiaoyan; Thakar, Juilee; Mallon, COL Timothy M.; Utell, Mark J.; Phipps, Richard P.
2017-01-01
Objective The aim of this study was to investigate whether serum samples from the Department of Defense Serum Repository (DoDSR) are of sufficient quality to detect microRNAs (miRNAs), cytokines, immunoglobulin E (IgE), and polycyclic aromatic hydrocarbons (PAHs). Methods MiRNAs were isolated and quantified by polymerase chain reaction (PCR) array. Cytokines and chemokines related to inflammation were measured using multiplex immunoassays. Cotinine and IgE were detected by enzyme-linked immunoassay (ELISA) and PAHs were detected by Liquid Chromatography/Mass Spectroscopy. Results We detected miRNAs, cytokines, IgE, and PAHs with high sensitivity. Eleven of 30 samples tested positive for cotinine suggesting tobacco exposure. Significant associations between serum cotinine, cytokine, IgE, PAHs, and miRNA were discovered. Conclusion We successfully quantified over 200 potential biomarkers of occupational exposure from DoDSR samples. The stored serum samples were not affected by hemolysis and represent a powerful tool for biomarker discovery and analysis in retrospective studies. PMID:27501106
Lesiak, Aleksandra; Zakrzewski, Marcin; Przybyłowska, Karolina; Rogowski-Tylman, Michał; Wozniacka, Anna; Narbutt, Joanna
2014-12-22
Atopic dermatitis (AD) is a chronic skin inflammatory disease in which Th2-derived cytokines play an essential role. Aim of the study was to assess interleukin 4, 10 and 13 (IL-4, IL-10 and IL-13) serum concentrations in AD patients and to correlate the values with the occurrence of genotypes of selected polymorphisms in genes encoding these cytokines. Seventy-six AD patients (mean age 11.4 years) and 60 healthy controls were enrolled in the study. Blood samples were analyzed for IL-4, IL-10 and IL-13 concentrations with ELISA assay and genotyping for -590C/T IL-4, -1082A/G IL-10 and -1055C/T IL-13 polymorphisms with PCR-RFLP. The obtained results revealed statistically higher serum concentration of IL-10 and IL-13 in AD patients when compared to healthy controls (10.30 pg/ml vs. 8.51 pg/ml for IL-10 and 5.67 pg/ml vs. 4.98 pg/ml for IL-13). There were no significant differences between AD patients and controls in regard to IL-4 serum level (5.10 pg/ml vs. 7.1 pg/ml). Analyzing the association between level of the examined cytokines and genotype polymorphisms -590 C/T for the IL-4 gene, -1082 A/G for the IL-10 gene and -1055 C/T for the IL-13 gene, we found a statistically higher IL-10 serum level among carriers of the G allele in the -1082 G/A IL-10 polymorphism both in AD and control groups. We did not find any significant differences between serum level of IL-4 and IL-13 in regard to genotype occurrence in examined polymorphisms: -590 C/T for the IL-4 gene and -1055 C/T for the IL-13 gene. The obtained results confirm the genetic background of IL-10 synthesis in the Polish population.
Dannaoui, Eric; Gabriel, Frédéric; Gaboyard, Manuel; Lagardere, Gaëlle; Audebert, Lucile; Quesne, Gilles; Godichaud, Sandrine; Verweij, Paul E; Accoceberry, Isabelle; Bougnoux, Marie-Elisabeth
2017-11-01
Aspergillus fumigatus is the main species responsible for aspergillosis in humans. The diagnosis of aspergillosis remains difficult, and the rapid emergence of azole resistance in A. fumigatus is worrisome. The aim of this study was to validate the new MycoGENIE A. fumigatus real-time PCR kit and to evaluate its performance on clinical samples for the detection of A. fumigatus and its azole resistance. This multiplex assay detects DNA from the A. fumigatus species complex by targeting the multicopy 28S rRNA gene and specific TR 34 and L98H mutations in the single-copy-number cyp51A gene of A. fumigatus The specificity of cyp51A mutation detection was assessed by testing DNA samples from 25 wild-type or mutated clinical A. fumigatus isolates. Clinical validation was performed on 88 respiratory samples obtained from 62 patients and on 69 serum samples obtained from 16 patients with proven or probable aspergillosis and 13 patients without aspergillosis. The limit of detection was <1 copy for the Aspergillus 28S rRNA gene and 6 copies for the cyp51A gene harboring the TR 34 and L98H alterations. No cross-reactivity was detected with various fungi and bacteria. All isolates harboring the TR 34 and L98H mutations were accurately detected by quantitative PCR (qPCR) analysis. With respiratory samples, qPCR results showed a sensitivity and specificity of 92.9% and 90.1%, respectively, while with serum samples, the sensitivity and specificity were 100% and 84.6%, respectively. Our study demonstrated that this new real-time PCR kit enables sensitive and rapid detection of A. fumigatus DNA and azole resistance due to TR 34 and L98H mutations in clinical samples. Copyright © 2017 American Society for Microbiology.
Gunay, Nurullah; Kekec, Zeynep; Demiryurek, Seniz; Kose, Ataman; Namiduru, Emine S; Gunay, Nahide E; Sari, Ibrahim; Demiryurek, Abdullah T
2010-02-01
Although atropine and oximes are traditionally used in the management of organophosphate poisoning, investigations have been directed to finding additional therapeutic approaches. Thus, the aim of this study was to evaluate the cardiac effects of magnesium sulfate pretreatment on dichlorvos intoxication in rats. Rats were randomly divided into three groups as control, dichlorvos, and magnesium sulfate groups. After 6 h of dichlorvos or corn oil (as a vehicle) injection, venous blood samples were collected, and cardiac tissue samples were obtained. Biochemical analyses were performed to measure some parameters on serum and cardiac tissue. Immunohistochemical analyses of apoptosis and inducible nitric oxide (NO) synthase showed no change in cardiac tissue. Serum cholinesterase levels were markedly depressed with dichlorvos, and further suppressed markedly with magnesium sulfate pretreatment. Although we have demonstrated that serum NO levels in dichlorvos and magnesium sulfate groups were lower than the control group, cardiac tissue NO levels in magnesium sulfate group were higher than the other two groups. Mortality was not significantly affected with magnesium sulfate pretreatment. Uncertainty still persists on the right strategies for the treatment of organophosphate acute poisoning; however, it was concluded that our results do not suggest that magnesium sulfate therapy is beneficial in the management of acute dichlorvos-induced organophosphate poisoning, and also further studies are required.
Franzen-Rohl, Elisabeth; Larsson, Kenny; Skoog, Eva; Tiveljung-Lindell, Annika; Grillner, Lena; Aurelius, Elisabeth; Glimåker, Martin
2008-01-01
Acute aseptic meningitis (AAM) affects 10-20/100,000 inhabitants per years in Sweden. Up to the beginning of the 1980s the diagnoses were made by virus isolation and/or determination of viral antibodies in serum. The development of PCR for detection of viruses in CSF samples has increased the sensitivity and diagnostic efficiency considerably. We investigated the aetiology of AAM and the diagnostic efficiency in an adult population in Stockholm, using a limited first-line combination of microbiological assays. CSF and serum samples, consecutively collected in 419 patients with clinical symptoms of AAM in northern Stockholm during 1999-2004, were included. PCR assays for herpes simplex virus (HSV) DNA and enterovirus (EV) RNA in the CSF as well as ELISA for IgM in serum to tick-borne encephalitis virus (TBEV) were performed routinely. A viral diagnosis was obtained in 255 of the 419 cases (62%) with these routinely performed assays. Clinical findings in combination with additional diagnostic tests resulted in an overall aetiological yield of 72%. EV was the major causative agent (27%) followed by TBEV (21%) and HSV-2 (19%). We conclude that consistent use of CSF-PCR for EV and HSV and TBEV serology established a diagnosis in the majority of AAM patients.
[Seroprevalence of human toxoplasmosis in Ceuta].
Pérez-Rendón González, J; López Caminero, A
1992-02-01
To study the association between religion and sex with seropositivity of Toxoplasma gondii. A cross-sectional observational or prevalence study, with blind, at random distribution. Clinic in Ceuta (North Africa). We studied 100 serum, 50 from people of Christian religion and 50 of Muslim religion, and in each group 25 of each sex. Selection was by order of arrival until the different groups were covered. The serological surveys consisted of indirect Immunofluorescence according to AMBROISE-THOMAS, using Evans Blue as a countercolor, and indirect Hemagglutination, using Blomerleux kits. Of the total samples, we found 51% positive serum for IFI and 64% for HAI. According to ethnic groups, in the Christian population we obtained 32% by IFI and 40% by HAI. In the Muslim population, we obtained 70% by IFI and 88% of seropositives by HAI (p less than 0.01). According to sexes, in males we obtained 46% by IFI and 64% by HAI of positives. In females we obtained 56% with IFI and 64% with HAI (p = insignificant). Our survey reflects a level of endemic above the world average in accordance with the WHO. This can be justified in the Muslim population who generally have a lower socio-economical and cultural level as well as their eating habits. Owing to the high prevalence of this zoonosis, we believe it requires greater consideration.
Serological, Bacteriological, and Molecular Diagnosis of Brucellosis in Domestic Animals in Croatia
Špičić, Silvio; Zdelar-Tuk, Maja; Račić, Ivana; Duvnjak, Sanja; Cvetnić, Željko
2010-01-01
Aim To present the surveillance data on Brucella melitensis, B. suis, and B. ovis infection in cattle, sheep, goats, and swine in Croatia obtained in 2008 by serological, bacteriological, and molecular methods for diagnostics of brucellosis in domestic animals. Methods We serologically tested 42 785 cattle serums, 22 686 sheep and goat serums, and 28 520 swine serums using the Rose Bengal test, complement fixation test, and various immunosorbent assays. We also tested 10 173 ram blood samples for B. ovis infection using the complement fixation test. Bacteriological examination was conducted on 214 samples collected from 34 serologically positive animals. Different molecular methods were employed in the identification and typing of 20 isolates from the samples. Results B. melitensis biovar (bv.) 3 was confirmed with different identification methods in 2 flocks in 2 Croatian counties and B. suis bv. 2 in 3 herds in 3 counties. B. melitensis in cows was confirmed for the first time in Croatia. Infection with B. ovis was serologically confirmed in 202 rams in 12 counties. Conclusions In 2008, the size of the brucellosis-affected area in Croatia and the efficiency of detection and prevention of brucellosis in sheep, goats, and swine were satisfactory. Infection with B. melitensis in cattle was confirmed for the first time and possible links for infection in humans were detected. More efficient measures for suppression and control of ovine epididymitis are required and a new strategy may be necessary for complete eradication of this disease. PMID:20718085
Tiwari, Dileep; Haque, Shafiul; Tiwari, Ram P; Jawed, Arshad; Govender, Thavendran; Kruger, Hendrik G
2017-04-01
A rapid and efficient diagnostic test was developed for the detection of Mycobacterium tuberculosis antigens in serum samples of active tuberculosis (TB) and extrapulmonary TB patients via a liposomal agglutination-based method. A rapid card test has been developed to facilitate the recognition of high-affinity binding rabbit raised purified culture filtrate protein antibodies coupled on the surface of activated liposomal preparation. In the presence of TB antigens, the polyclonal antibodies bound to the liposomal particles demonstrate a visible agglutination reaction. The developed assay was simple, rapid, reliable, sensitive, and specific as a diagnostic test for the detection of antigens in serum samples of clinically confirmed cases of TB within 4-5 minutes' duration. The test was evaluated at different hospitals, medical colleges, and pathology centers, and involved 1483 participants. This investigation was conducted to detect the presence of these antigens during the period of active growth of the microorganism in serum samples for pulmonary TB and processed tissue biopsy for other extrapulmonary TB. Results obtained using this test were compared with acid-fast bacilli smear and culture results. Our study demonstrated that the newly developed liposome tuberculosis antigen card test detected antigens in our study population with approximately 97.48% sensitivity and 95.79% specificity. This is the first study to report the liposomal encapsulation of culture filtrate proteins from M. tuberculosis for diagnostic application. Copyright © 2015. Published by Elsevier B.V.
Ha, Li-ya; A, Da-lat; Zhong, Liang-jun; Feng, Jin-hong
2004-12-01
The purpose of this investigation was to analyze by cross-sectional design the association between GCF IL-6 level, serum E2 level and common clinical measurements of periodontitis in Uyghur postmenopausal women. 79 subjects within 5 years after menopause were enrolled in the study. 30 GCF samples were harvested from healthy sites, 49 GCF samples from chronic periodontitis sites. Clinical measurements of each tooth were recorded after obtaining GCF samples. GCF IL-6 and serum E2 levels were measured by radioimmunoassay (RIA). The mean concentration of GCF IL-6 from healthy sites was (1088.10+/-102.33)pg/ml.The mean concentration of IL-6 from chronic periodontitis sites was significantly higher than that of healthy sites (P<0.005). Positive correlation was found between GCF IL-6 level and clinical measurements (GI, PPD and CAL) (r=0.564, P<0.005; r=0.335, P<0.05; r=0.324, P<0.05). Clinical measurements and GCF IL-6 levels of chronic periodontitis subjects were not different between E2-deficient and E2-sufficient subjects. These findings suggest that there is lower IL-6 level in GCF from healthy sites; the increasing production of IL-6 may be associated with the initiation and progress of periodontitis. IL-6 may be a valuable indicator of the severity of periodontitis; E2 level is not associated with clinical measurements and GCF IL-6 level of chronic periodontitis of Uyghuy woman in early menopause.
Jensen, Berit P; Saraf, Rajneeta; Ma, Jing; Berry, Sarah; Grant, Cameron C; Camargo, Carlos A; Sies, Christiaan W
2018-06-01
Demand for measurement of 25-hydroxyvitamin D (25OHD) is growing and dried blood spot (DBS) sampling is attractive as samples are easier to collect, transport and store. A 2D LC-MS/MS assay without derivatization was developed. DBS punches (3.2 mm) were ultrasonicated with d 6 -25OHD 3 in 70% methanol followed by hexane extraction, dry-down and reconstitution. The assay was validated and applied to two studies comparing whole blood adult DBS with serum samples (n = 40) and neonatal whole blood DBS with cord serum samples (n = 80). The assay was validated in whole blood DBS over the range 13-106 nmol/L 25OHD 3 and 11-91 nmol/L 25OHD 2 with a limit of detection of 3 nmol/L. Intra- and inter-day imprecision was <13% CV and bias <12%. The assay had high recovery and minimal matrix effects. Triplicate DBS study samples had a mean CV of ≤13% for 25OHD 3. No 25OHD 2 was detected. DBS calculated serum 25OHD 3 concentrations correlated strongly with serum concentrations in the adult DBS/serum study (r = 0.94) and moderately in the neonatal DBS/cord serum study (r = 0.69). Direct quantitation of 25OHD in DBS by 2D LC-MS/MS without derivatization was found to be an alternative to serum quantitation applicable to clinical research studies on adult DBS samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Yang, Xiao-min; Yang, Hua
2013-07-01
To explore the expression of high mobility group box-1 (HMGB1) in the lung tissue and serum of patients with pulmonary tuberculosis and to explore its relationship with tumor necrosis factor (TNF)-α and interleukin(IL)-1β. Sixty samples of lung tissues were obtained from patients with pulmonary tuberculosis who had underwent pneumonectomy in Department of Chest Surgery, First Affiliated Hospital of Zunyi Medical College from June 2010 to December 2011. At the same period, 40 normal lung samples were also obtained from patients with pulmonary contusion and lung cancer by surgical resections as the control group. The mRNA expressions of HMGB1 was detected by reverse transcription-polymerase chain reaction (RT-PCR), and the protein level of HMGB1 was measured by immunohistochemical staining of tissue microarrays in lung tissue. Blood samples were taken from 89 patients with active pulmonary tuberculosis (pulmonary tuberculosis group), including hematogenous disseminated pulmonary tuberculosis (type II) in 35 cases and secondary pulmonary tuberculosis (type III) in 54 cases, and 50 healthy volunteers (control group). Furthermore, the 54 patients with secondary pulmonary tuberculosis were divided into different subgroups according to cavity formation and the lung fields involved: patients without lung cavity (35 cases) vs those with lung cavity (19 cases), patients with involvement of <2 lung fields (31 cases) vs ≥ 2 lung fields (23 cases). Serum concentration of HMGB1, TNF-α and IL-1β were detected by ELISA. Two sample t-test was used to compare date among groups, liner correlation analysis was established for correlation analysis. The average optical density of HMGB1 in pulmonary tuberculosis (69 ± 29) was significantly higher than that in normal lung tissue (22 ± 12) (t = 2.389, P < 0.05). The mRNA relative transcript levels of HMGB1 in pulmonary tuberculosis (786 ± 86) was significantly higher than that in normal lung tissue (202 ± 60) (t = 3.872, P < 0.01). The serum concentration of HMGB1, TNF-α and IL-1β in the pulmonary tuberculosis group were (5.0 ± 3.2) µg/L, (118 ± 77) ng/L and (33 ± 20) ng/L, respectively, which were significantly higher than those in the control group [(1.7 ± 1.0) µg/L, (40 ± 11) ng/L and (18 ± 12) ng/L, respectively], the respective t values being -0.928, 4.268 and 11.064, all P < 0.01. In the subgroup of patients with hematogenous disseminated pulmonary tuberculosis, the serum concentration of HMGB1 and TNF-α[ (6.4 ± 3.3) µg/L, (147 ± 89) ng/L] were significantly higher than those in patients with secondary pulmonary tuberculosis [(4.1 ± 2.7) µg/L, (85 ± 37) ng/L] (t = 3.643 and t = 3.111, both P < 0.01). HMGB1 were correlated positively with TNF-α and IL-1β (r = 0.722 and r = 0.620, P < 0.01, respectively, n = 89) in the pulmonary tuberculosis group. Overexpression of HMGB1 in the lung tissue and serum of patients with pulmonary tuberculosis may play an important role in the inflammatory response of pulmonary tuberculosis. The measurement of serum HMGB1 is useful to evaluate the severity of disease.
Vijaylakshmi, P; Muthukkaruppan, V R; Rajasundari, A; Korukluoglu, G; Nigatu, W; L A Warrener; Samuel, D; Brown, D W G
2006-12-01
Clinical diagnosis (surveillance) of rubella is unreliable and laboratory confirmation is essential. Detection of virus specific IgM in serum is the most commonly used method. However, the use of serum necessitates the drawing of blood, either through venipuncture or finger/heel prick, which can be difficult in young babies. Oral fluid samples have proved useful as an alternative, less invasive sample for virus specific IgM detection however until recently no commercial rubella IgM tests were available, restricting the usefulness of this approach. To evaluate the performance of the Microimmune Rubella IgM capture EIA using oral fluid samples from outbreaks as well as in cases of suspected congenital rubella syndrome (CRS). Paired serum and oral fluids were collected from cases during a rubella outbreak in three provinces in Turkey. Matched serum and oral fluid samples were collected from children with suspected CRS in an active surveillance programme at the Aravind Eye Hospital in South India. Serum samples were collected as part of the measles surveillance programme in Ethiopia. On serum samples the sensitivity and specificity of the Microimmune Rubella IgM capture EIA compared to Behring Enzygnost rubella IgM test was 96.9% (62/64; 95% CI 94.2-100%) and 100% (53/53; 95% CI 93.2-100%). On oral fluids compared to matched Behring results on serum the sensitivity was 95.5% (42/44; 95% CI 84.5-99.4%). The sensitivity and specificity of Microimmune Rubella IgM capture EIA on oral fluids from suspected CRS cases compared to serum results using Behring Enzygnost IgM assay was 100% (95% CI 84.5-100%) and 100% (95% CI 95.8-100.0%) respectively. Microimmune Rubella IgM capture EIA has adequate performance for diagnosis and surveillance of rubella in outbreak using either serum or oral fluid specimens.
Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils
2014-01-01
Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.
Lindström, Mikael; Tohmola, Niina; Renkonen, Risto; Hämäläinen, Esa; Schalin-Jäntti, Camilla; Itkonen, Outi
2018-07-01
Serotonin (5-hydroxytyramine) is a mediator of gastrointestinal smooth muscle contraction, and is secreted by neuroendocrine neoplasms (NENs). We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum serotonin to be used in NEN diagnostics and follow-up. We used serum samples from healthy volunteers (n = 31) and patients suspected or monitored for NEN (n = 98). Serotonin-D 4 internal standard was added to samples before solid phase extraction (SPE) and quantification by LC-MS/MS. The effects of sample handling and preparation on serotonin stability were studied. Finally, we established a provisional reference range for serum serotonin and compared our assay with serum 5-hydroxyindoleacetic acid (5-HIAA) for detection of NENs. Our assay is sensitive and has a wide linear range (10-10,000 nmol/l). Serum serotonin is stable for 7 days at room temperature and for 3 months at -20 °C. Sampling temperature is not critical. Normal range for serum serotonin was 270-1490 nmol/l. We found that serum serotonin and 5-HIAA performed equally well as diagnostic tests for NENs. Our LC-MS/MS assay for serum serotonin is well suited for clinical research and patient diagnostics. Our results confirm that it can complement 5-HIAA in diagnosis of NENs. Copyright © 2018 Elsevier B.V. All rights reserved.
Codices, Vera; Martins, Catarina; Novo, Carlos; de Sousa, Bruno; Lopes, Ângela; Borrego, Miguel; Matos, Olga
2013-01-01
Infection by Cryptosporidium parvum triggers a complex array of innate and adaptive cell mediated immune response, playing an important role in controlling the infection. To date, there are no studies applying the Luminex® xMAP technology to determine profiles of cytokines and immunoglobulins in the context of an infection by C. parvum. In this study, we analyzed these immune mediators in the serum of immunocompetent mice inoculated with C. parvum oocysts, using Luminex, to understand how the immune system responds to an infection by this parasite. Animal sera were also analyzed by ELISA to determine the expressed immunoglobulin isotype profile, and compare the obtained trend with data obtained by Luminex. Specific-pathogen-free BALB/C mice were inoculated with oocysts of C. parvum at days 0 and 22. Peripheral blood was aseptically collected from sacrificed mice on several time points, and immune mediators were evaluated in serum samples. Infection was confirmed by the presence of C. parvum DNA in feces by a nested-PCR assay (60-kDa glycoprotein). Luminex results showed predominance in the secretion of IgG1 and IgG2a, confirmed by ELISA, which also showed that IgG1 is the major immunoglobulin isotype produced during the infection. The analysis of cytokines suggests a preferential Th(1) over the Th(2) response, with increased production of TNF-α, IFN-γ and GM-CSF. This work contributed to a better understanding of the immune response to the infection by C. parvum, as well as demonstrated the advantage of Luminex® xMAP technology to study immune mediators, using small sample volumes. Copyright © 2012 Elsevier Inc. All rights reserved.
Ditu, L M; Chifiriuc, M C; Bezirtzoglou, E; Marutescu, L; Bleotu, C; Pelinescu, D; Mihaescu, G; Lazar, V
2014-01-01
Competition of probiotic bacteria with other species from the intestinal microbiota involves different mechanisms that occur regardless of probiotics' viability. The objective of this paper was to assess the cytokine serum levels in holoxenic mice after oral administration of non-viable components (NVC) of Enterococcus faecium probiotic culture stimulated with heat-inactivated Escherichia coli and Bacillus cereus in comparison to NVC of unstimulated E. faecium probiotic culture. Probiotic E. faecium CMGb 16 culture, grown in the presence of heat-inactivated cultures of E. coli and B. cereus CMGB 102, was subsequently separated into supernatant (SN) and heat-inactivated cellular sediment (CS) fractions by centrifugation. Each NVC was orally administered to holoxenic mice (balb C mouse strain), in three doses, given at 24 hours. Blood samples were collected from the retinal artery, at 7, 14, and 21 days after the first administration of the NVC. The serum concentrations of IL-12 and tumor necrosis factor-alpha (TNF-α) interleukins were assessed by ELISA method. After the oral administration of SN component obtained from the probiotic culture stimulated with heat-inactivated cultures of B. cereus CMGB 102 and E. coli O28, the serum concentrations of IL-12 were maintained higher in the samples collected at 7 and 14 days post-administration. No specific TNF-α profile could be established, depending on stimulated or non-stimulated probiotic culture, NVC fraction, or harvesting time. The obtained results demonstrate that non-viable fractions of probiotic bacteria, stimulated by other bacterial species, could induce immunostimulatory effects mediated by cytokines and act, therefore, as immunological adjuvants.
Mamdouh, Samah; Khorshed, Fatma; Aboushousha, Tarek; Hamdy, Hussam; Diab, Ayman; Seleem, Mohamed; Saber, Mohamed
2017-11-26
HCV induced hepatitis and hepatocellular carcinoma as its sequel are major health problems world-wide and especially in Egypt. For diagnosis and during treatment of liver diseases, liver functions are monitored through determination of serum levels of liver enzymes and α-fetoprotein although the obtained information is generally not sufficient for either early detection of hepatic insult or effective follow up of therapeutic effects. More sensitive biomarkers may help to achieve these goals. MiRNAs are small non-coding RNAs that have an important role in gene expression and regulation. Many, such as miR-224, miR-215, miR-143 are correlated with tumor appearance and with the degree of fibrosis in lung, breast and colon cancer. This study was performed to estimate the level of these miRNAs in serum of patients with HCV-associated hepatitis and HCC in relation to grade of hepatitis, stage of fibrosis and differentiation of tumor tissue. In addition, correlations between serological and tissue levels were assessed. A total of 80 patients were examined, out of which 50 were included in the study. Blood samples and tissue specimens from malignant tumor and corresponding non-tumor tissue of HCV hepatitis patients were collected. Blood samples from 20 healthy volunteers were also obtained as controls. It was found that miRNAs profiles differed in HCC patients compared to controls and HCV-associated hepatitis cases. Distinction of tumor grade and fibrosis stage of patients as well as between different grades of tumor differentiation proved possible, making miRNAs promising biomarkers for diagnosis and assessment of treatment response of HCC patients. Creative Commons Attribution License
Bukbuk, David Nadeba; Fukushi, Shuetsu; Tani, Hideki; Yoshikawa, Tomoki; Taniguchi, Satoshi; Iha, Koichiro; Fukuma, Aiko; Shimojima, Masayuki; Morikawa, Shigeru; Saijo, Masayuki; Kasolo, Francis; Baba, Saka Saheed
2014-12-01
Rift Valley fever (RVF) is endemic to the tropical regions of eastern and southern Africa. The seroprevalence of RVF was investigated among the human population in Borno State, Nigeria to determine the occurrence of the disease in the study area in comparison with that of Lassa fever and Crimean-Congo Hemorrhagic fever. Recombinant nucleoprotein (rNP)-based IgG-ELISAs for the detection of serum antibodies against RVF virus (RVFV), Lassa fever virus (LASV), and Crimean-Congo hemorrhagic fever virus (CCHFV) were used to test human sera in Borno State, Nigeria. The presence of neutralizing antibody against the RVFV-glycoprotein-bearing vesicular stomatitis virus pseudotype (RVFVpv) was also determined in the human sera. Of the 297 serum samples tested, 42 (14.1%) were positive for the presence of RVFV-IgG and 22 (7.4%) and 7 (2.4%) of the serum samples were positive for antibodies against LASV and CCHFV, respectively. There was a positive correlation between the titers of neutralizing antibodies obtained using RVFVpv and those obtained using the conventional neutralization assay with the attenuated RVFV-MP12 strain. The seroprevalence of RVF was significantly higher than that of LASV and CCHF in Borno State, Nigeria. The RVFVpv-based neutralization assay developed in this study has the potential to replace the traditional assays based on live viruses for the diagnosis and seroepidemiological studies of RVF. © The Author 2014. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Development of in-house serological methods for diagnosis and surveillance of chikungunya.
Galo, Saira Saborío; González, Karla; Téllez, Yolanda; García, Nadezna; Pérez, Leonel; Gresh, Lionel; Harris, Eva; Balmaseda, Ángel
2017-08-21
To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014-2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention's IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%-95.9%. Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease.
Development of in-house serological methods for diagnosis and surveillance of chikungunya
Galo, Saira Saborío; González, Karla; Téllez, Yolanda; García, Nadezna; Pérez, Leonel; Gresh, Lionel; Harris, Eva; Balmaseda, Ángel
2017-01-01
Objective To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Methods Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014–2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention’s IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. Results All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%–95.9%. Conclusion Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease. PMID:28902269
Oliveira, Rafael Caputo; Pralle, Ryan S.; de Resende, Lucas C.; Nova, Carlos Henrique P. C.; Caprarulo, Valentina; Jendza, Joshua A.; Troescher, Arnulf
2018-01-01
Prepartum supplementation with conjugated linoleic acid (CLA) may influence lipolysis and hyperketonemia in dairy cows. The objective of this study was to examine the effect of prepartum CLA supplementation on lactation performance and serum fatty acids (FA) and β-hydroxybutyrate (BHB) in early lactation dairy cows, and secondarily on reproductive performance. Multiparous cows were enrolled in the study at 18 days prior to expected calving date, and randomly assigned 100 g/day of Lutrell Pure (BASF, Ludwigshafen, Germany; 75% FA), providing 10 g/day of each CLA isomer (trans-10 cis-12 and cis-9 trans-11 CLA) or equivalent amount of rumen inert fatty acids as control (78 g/day of Energy Booster 100; Milk Specialties Global, Eden Prairie, MN). Treatments were top dressed daily to individual cows from enrollment to calving and all cows were offered the same ration. Blood samples were collected on the first day of supplementation, 10 days prepartum, and 1, 7, 14, and 30 days postpartum. Hyperketonemia was defined as serum BHB ≥ 1.2 mM. Milk yield was recorded daily until 60 days postpartum and averaged weekly. Milk samples were obtained weekly for component analysis. Prepartum CLA supplementation tended to increase serum concentration of cis-9, trans-11 CLA and increased trans-10, cis-12 CLA prepartum. Cows supplemented with CLA had increased milk protein yield and tended to have increased milk fat yield and milk yield, which together resulted in greater energy content of milk. Cows supplemented with CLA had lower serum FA on day 1 and 7 postpartum and overall lower serum BHB postpartum, which resulted in decreased prevalence of hyperketonemia on day 14 postpartum. There were no differences in body condition score change, other health disorders, or reproductive outcomes by treatment. Together, these findings indicate that prepartum CLA supplementation may be a plausible strategy to positively influence postpartum performance. PMID:29772023
de Jesus, Jemmyson Romário; Galazzi, Rodrigo Moretto; de Lima, Tatiani Brenelli; Banzato, Cláudio Eduardo Muller; de Almeida Lima E Silva, Luiz Fernando; de Rosalmeida Dantas, Clarissa; Gozzo, Fábio Cézar; Arruda, Marco Aurélio Zezzi
2017-12-01
An exploratory analysis using proteomic strategies in blood serum of patients with bipolar disorder (BD), and with other psychiatric conditions such as Schizophrenia (SCZ), can provide a better understanding of this disorder, as well as their discrimination based on their proteomic profile. The proteomic profile of blood serum samples obtained from patients with BD using lithium or other drugs (N=14), healthy controls, including non-family (HCNF; N=3) and family (HCF; N=9), patients with schizophrenia (SCZ; N=23), and patients using lithium for other psychiatric conditions (OD; N=4) were compared. Four methods for simplifying the serum samples proteome were evaluated for both removing the most abundant proteins and for enriching those of lower-abundance: protein depletion with acetonitrile (ACN), dithiothreitol (DTT), sequential depletion using DTT and ACN, and protein equalization using commercial ProteoMiner® kit (PM). For proteomic evaluation, 2-D DIGE and nanoLC-MS/MS analysis were employed. PM method was the best strategy for removing proteins of high abundance. Through 2-D DIGE gel image comparison, 37 protein spots were found differentially abundant (p<0.05, Student's t-test), which exhibited ≥2.0-fold change of the average value of normalized spot intensities in the serum of SCZ, BD and OD patients compared to subject controls (HCF and HCNF). From these spots detected, 13 different proteins were identified: ApoA1, ApoE, ApoC3, ApoA4, Samp, SerpinA1, TTR, IgK, Alb, VTN, TR, C4A and C4B. Proteomic analysis allowed the discrimination of patients with BD from patients with other mental disorders, such as SCZ. The findings in this exploratory study may also contribute for better understanding the pathophysiology of these disorders and finding potential serum biomarkers for these conditions. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Apelin-13 increased food intake with serum ghrelin and leptin levels in male rats.
Saral, S; Alkanat, M; Sumer, A; Canpolat, S
2018-01-01
In this study, we aimed to explain the role of apelin-13 on body weight, food and water intake with serum leptin, ghrelin, neuropeptid Y (NPY) and peptid YY (PYY) levels in male rat. Thirty-two Sprague-Dawley male rats were used for the study. The rats were injected SP (0.9 %) intraperitoneally (i.p) in the control group and 30 (AP30), 100 (AP100) and 300 (AP300) µg/kg apelin-13 in the study groups, respectively, 10 min before the transition to dark period, for 10 days. During the experimental period, with light and dark periods of food and water intake, body weights were recorded in rats. Rats were euthanized and serum samples were obtained. In serum samples leptin, ghrelin, NPY and PYY levels were measured with specific ELISA kit. Apelin-13 was increased body weights in all three (AP30, AP100 and AP300) groups compared with the control group. AP100 and AP300 groups had increased food intake in the dark and the cumulative period, but in the light period food intake values were not significantly increased (p > 0.05). As for the value of water intake, compared with the control group, all dose of apelin-13 increased water intake during the dark and the cumulative period. There was no significant change in water intake in the light period. On the other hand, compared with the control group, serum leptin levels were found to increase in the groups administered 100 and 300 µg/kg of apelin-13 (p < 0.05). Ghrelin levels were found high in all groups treated with apelin-13. Serum levels of NPY decreased only in the 300 µg/kg apelin-13 treated group (p 0.05). Apelin-13 increases body weight in rats as well as food and water intake (dark and cumulative period). Additionally, ghrelin can mediate the orexigenic effect of apelin-13 in the regulation of food intake (Fig. 4, Ref. 37).
Engwegen, Judith Y M N; Helgason, Helgi H; Cats, Annemieke; Harris, Nathan; Bonfrer, Johannes M G; Schellens, Jan H M; Beijnen, Jos H
2006-03-14
To detect the new serum biomarkers for colorectal cancer (CRC) by serum protein profiling with surface-enhanced laser desorption ionisation--time of flight mass spectrometry (SELDI-TOF MS). Two independent serum sample sets were analysed separately with the ProteinChip technology (set A: 40 CRC+49 healthy controls; set B: 37 CRC+31 healthy controls), using chips with a weak cation exchange moiety and buffer pH 5. Discriminative power of differentially expressed proteins was assessed with a classification tree algorithm. Sensitivities and specificities of the generated classification trees were obtained by blindly applying data from set A to the generated trees from set B and vice versa. CRC serum protein profiles were also compared with those from breast, ovarian, prostate, and non-small cell lung cancer. Mass-to-charge ratios (m/z) 3.1x10(3), 3.3x10(3), 4.5x10(3), 6.6x10(3) and 28x10(3) were used as classifiers in the best-performing classification trees. Tree sensitivities and specificities were between 65% and 90%. Most of these discriminative m/z values were also different in the other tumour types investigated. M/z 3.3x10(3), main classifier in most trees, was a doubly charged form of the 6.6x10(3)-Da protein. The latter was identified as apolipoprotein C-I. M/z 3.1x10(3) was identified as an N-terminal fragment of albumin, and m/z 28x10(3) as apolipoprotein A-I. SELDI-TOF MS followed by classification tree pattern analysis is a suitable technique for finding new serum markers for CRC. Biomarkers can be identified and reproducibly detected in independent sample sets with high sensitivities and specificities. Although not specific for CRC, these biomarkers have a potential role in disease and treatment monitoring.
Zeitoun, H; Bahey-El-Din, M; Kassem, M A; Aboushleib, H M
2017-12-01
Mycobacterium tuberculosis infection constitutes a global threat that results in significant morbidity and mortality worldwide. Efficient and early diagnosis of tuberculosis (TB) is of paramount importance for successful treatment. The aim of the current study is to investigate the mycobacterial mycothiol acetyltransferase Rv0819 as a potential novel biomarker for the diagnosis of active TB infection. The gene encoding Rv0819 was cloned and successfully expressed in Escherichia coli. The recombinant Rv0819 was purified using metal affinity chromatography and was used to raise murine polyclonal antibodies against Rv0819. The raised antibodies were employed for direct detection of Rv0819 in patient serum samples using dot blot assay and competitive enzyme-linked immunosorbent assay (ELISA). Serum samples were obtained from 68 confirmed new TB patients and 35 healthy volunteers as negative controls. The dot blot assay showed sensitivity of 64·7% and specificity of 100%, whereas the competitive ELISA assay showed lower sensitivity (54·4%) and specificity (88·57%). The overall sensitivity of the combined results of the two tests was found to be 89·7%. Overall, the mycobacterial Rv0819 is a potential TB serum biomarker that can be exploited, in combination with other TB biomarkers, for efficient and reliable diagnosis of active TB infection. The early and accurate diagnosis of tuberculosis infection is of paramount importance for initiating treatment and avoiding clinical complications. Most current diagnostic tests have poor sensitivity and/or specificity and in many cases they are too expensive for routine diagnostic testing in resource-limited settings. In the current study, we examined a novel mycobacterial serum biomarker, namely mycothiol acetyltransferase Rv0819. The antigen was detectable in serum specimens of a significant number of tuberculosis patients. This article proves the importance of Rv0819 and paves the way towards its future use as a useful diagnostic marker for tuberculosis infection. © 2017 The Society for Applied Microbiology.