ARCGRAPH SYSTEM - AMES RESEARCH GRAPHICS SYSTEM
NASA Technical Reports Server (NTRS)
Hibbard, E. A.
1994-01-01
Ames Research Graphics System, ARCGRAPH, is a collection of libraries and utilities which assist researchers in generating, manipulating, and visualizing graphical data. In addition, ARCGRAPH defines a metafile format that contains device independent graphical data. This file format is used with various computer graphics manipulation and animation packages at Ames, including SURF (COSMIC Program ARC-12381) and GAS (COSMIC Program ARC-12379). In its full configuration, the ARCGRAPH system consists of a two stage pipeline which may be used to output graphical primitives. Stage one is associated with the graphical primitives (i.e. moves, draws, color, etc.) along with the creation and manipulation of the metafiles. Five distinct data filters make up stage one. They are: 1) PLO which handles all 2D vector primitives, 2) POL which handles all 3D polygonal primitives, 3) RAS which handles all 2D raster primitives, 4) VEC which handles all 3D raster primitives, and 5) PO2 which handles all 2D polygonal primitives. Stage two is associated with the process of displaying graphical primitives on a device. To generate the various graphical primitives, create and reprocess ARCGRAPH metafiles, and access the device drivers in the VDI (Video Device Interface) library, users link their applications to ARCGRAPH's GRAFIX library routines. Both FORTRAN and C language versions of the GRAFIX and VDI libraries exist for enhanced portability within these respective programming environments. The ARCGRAPH libraries were developed on a VAX running VMS. Minor documented modification of various routines, however, allows the system to run on the following computers: Cray X-MP running COS (no C version); Cray 2 running UNICOS; DEC VAX running BSD 4.3 UNIX, or Ultrix; SGI IRIS Turbo running GL2-W3.5 and GL2-W3.6; Convex C1 running UNIX; Amhdahl 5840 running UTS; Alliant FX8 running UNIX; Sun 3/160 running UNIX (no native device driver); Stellar GS1000 running Stellex (no native device driver); and an SGI IRIS 4D running IRIX (no native device driver). Currently with version 7.0 of ARCGRAPH, the VDI library supports the following output devices: A VT100 terminal with a RETRO-GRAPHICS board installed, a VT240 using the Tektronix 4010 emulation capability, an SGI IRIS turbo using the native GL2 library, a Tektronix 4010, a Tektronix 4105, and the Tektronix 4014. ARCGRAPH version 7.0 was developed in 1988.
PSTOOLS - FOUR PROGRAMS THAT INTERPRET/FORMAT POSTSCRIPT FILES
NASA Technical Reports Server (NTRS)
Choi, D.
1994-01-01
PSTOOLS is a package of four programs that operate on files written in the page description language, PostScript. The programs include a PostScript previewer for the IRIS workstation, a PostScript driver for the Matrix QCRZ film recorder, a PostScript driver for the Tektronix 4693D printer, and a PostScript code beautifier that formats PostScript files to be more legible. The three programs PSIRIS, PSMATRIX, and PSTEK are similar in that they all interpret the PostScript language and output the graphical results to a device, and they support color PostScript images. The common code which is shared by these three programs is included as a library of routines. PSPRETTY formats a PostScript file by appropriately indenting procedures and code delimited by "saves" and "restores." PSTOOLS does not use Adobe fonts. PSTOOLS is written in C-language for implementation on SGI IRIS 4D series workstations running IRIX 3.2 or later. A README file and UNIX man pages provide information regarding the installation and use of the PSTOOLS programs. A six-page manual which provides slightly more detailed information may be purchased separately. The standard distribution medium for this package is one .25 inch streaming magnetic tape cartridge in UNIX tar format. PSIRIS (the largest program) requires 1.2Mb of main memory. PSMATRIX requires the "gpib" board (IEEE 488) available from Silicon Graphics. Inc. The programs with graphical interfaces require that the IRIS have at least 24 bit planes. This package was developed in 1990 and updated in 1991. SGI, IRIS 4D, and IRIX are trademarks of Silicon Graphics, Inc. Matrix QCRZ is a registered trademark of the AGFA Group. Tektronix 4693D is a trademark of Tektronix, Inc. Adobe is a trademark of Adobe Systems Incorporated. PostScript is a registered trademark of Adobe Systems Incorporated. UNIX is a registered trademark of AT&T Bell Laboratories.
NASA Technical Reports Server (NTRS)
Schlecht, Leslie E.; Kutler, Paul (Technical Monitor)
1998-01-01
This is a proposal for a general use system based, on the SGI IRIS workstation platform, for recording computer animation to videotape. In addition, this system would provide features for simple editing and enhancement. Described here are a list of requirements for the system, and a proposed configuration including the SGI VideoLab Integrator, VideoMedia VLAN animation controller and the Pioneer rewritable laserdisc recorder.
PLOT3D/AMES, SGI IRIS VERSION (WITHOUT TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. In each of these areas, the IRIS implementation of PLOT3D offers advanced features which aid visualization efforts. Shading and hidden line/surface removal can be used to enhance depth perception and other aspects of the graphical displays. A mouse can be used to translate, rotate, or zoom in on views. Files for several types of output can be produced. Two animation options are even offered: creation of simple animation sequences without the need for other software; and, creation of files for use in GAS (Graphics Animation System, ARC-12379), an IRIS program which offers more complex rendering and animation capabilities and can record images to digital disk, video tape, or 16-mm film. The version 3.6b+ SGI implementations of PLOT3D (ARC-12783) and PLOT3D/TURB3D (ARC-12782) were developed for use on Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D workstations. These programs are each distributed on one .25 inch magnetic tape cartridge in IRIS TAR format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: (1) generic UNIX Supercomputer and IRIS, suitable for CRAY 2/UNICOS, CONVEX, and Alliant with remote IRIS 2xxx/3xxx or IRIS 4D (ARC-12779, ARC-12784); (2) VAX computers running VMS Version 5.0 and DISSPLA Version 11.0 (ARC-12777,ARC-12781); (3) generic UNIX and DISSPLA Version 11.0 (ARC-12788, ARC-12778); and (4) Apollo computers running UNIX and GMR3D Version 2.0 (ARC-12789, ARC-12785 which have no capabilities to put text on plots). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo and GMR3D are trademarks of Hewlett-Packard, Incorporated. UNIX is a registered trademark of AT&T.
PLOT3D/AMES, SGI IRIS VERSION (WITH TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. In each of these areas, the IRIS implementation of PLOT3D offers advanced features which aid visualization efforts. Shading and hidden line/surface removal can be used to enhance depth perception and other aspects of the graphical displays. A mouse can be used to translate, rotate, or zoom in on views. Files for several types of output can be produced. Two animation options are even offered: creation of simple animation sequences without the need for other software; and, creation of files for use in GAS (Graphics Animation System, ARC-12379), an IRIS program which offers more complex rendering and animation capabilities and can record images to digital disk, video tape, or 16-mm film. The version 3.6b+ SGI implementations of PLOT3D (ARC-12783) and PLOT3D/TURB3D (ARC-12782) were developed for use on Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D workstations. These programs are each distributed on one .25 inch magnetic tape cartridge in IRIS TAR format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: (1) generic UNIX Supercomputer and IRIS, suitable for CRAY 2/UNICOS, CONVEX, and Alliant with remote IRIS 2xxx/3xxx or IRIS 4D (ARC-12779, ARC-12784); (2) VAX computers running VMS Version 5.0 and DISSPLA Version 11.0 (ARC-12777,ARC-12781); (3) generic UNIX and DISSPLA Version 11.0 (ARC-12788, ARC-12778); and (4) Apollo computers running UNIX and GMR3D Version 2.0 (ARC-12789, ARC-12785 which have no capabilities to put text on plots). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo and GMR3D are trademarks of Hewlett-Packard, Incorporated. UNIX is a registered trademark of AT&T.
NASA Technical Reports Server (NTRS)
Melis, M. E.
1994-01-01
A significant percentage of time spent in a typical finite element analysis is taken up in the modeling and assignment of loads and constraints. This process not only requires the analyst to be well-versed in the art of finite element modeling, but also demands familiarity with some sort of preprocessing software in order to complete the task expediently. COMGEN (COmposite Model GENerator) is an interactive FORTRAN program which can be used to create a wide variety of finite element models of continuous fiber composite materials at the micro level. It quickly generates batch or "session files" to be submitted to the finite element pre- and post-processor program, PATRAN. (PDA Engineering, Costa Mesa, CA.) In modeling a composite material, COMGEN assumes that its constituents can be represented by a "unit cell" of a fiber surrounded by matrix material. Two basic cell types are available. The first is a square packing arrangement where the fiber is positioned in the center of a square matrix cell. The second type, hexagonal packing, has the fiber centered in a hexagonal matrix cell. Different models can be created using combinations of square and hexagonal packing schemes. Variations include two- and three- dimensional cases, models with a fiber-matrix interface, and different constructions of unit cells. User inputs include fiber diameter and percent fiber-volume of the composite to be analyzed. In addition, various mesh densities, boundary conditions, and loads can be assigned to the models within COMGEN. The PATRAN program then uses a COMGEN session file to generate finite element models and their associated loads which can then be translated to virtually any finite element analysis code such as NASTRAN or MARC. COMGEN is written in FORTRAN 77 and has been implemented on DEC VAX series computers under VMS and SGI IRIS series workstations under IRIX. If the user has the PATRAN package available, the output can be graphically displayed. Without PATRAN, the output is tabular. The VAX VMS version is available on a 5.25 inch 360K MS-DOS format diskette (standard distribution media) or a 9-track 1600 BPI DEC VAX FILES-11 format magnetic tape, and it requires about 124K of main memory. The standard distribution media for the IRIS version is a .25 inch streaming magnetic tape cartridge in UNIX tar format. The memory requirement for the IRIS version is 627K. COMGEN was developed in 1990. DEC, VAX and VMS are trademarks of Digital Equipment Corporation. PATRAN is a registered trademark of PDA Engineering. SGI IRIS and IRIX are trademarks of Silicon Graphics, Inc. MS-DOS is a registered trademark of Microsoft Corporation. UNIX is a registered trademark of AT&T.
NASA Astrophysics Data System (ADS)
Jaffe, P. R.; Pennino, M. J.; McDonald, R.
2015-12-01
Stormwater green infrastructure (SGI), including rain gardens, detention ponds, bioswales, and green roofs, is being implemented in cities across the globe to help reduce flooding, decrease combined sewer overflows, and lessen pollutant transport to streams and rivers. Despite the increasing use of urban SGI, there is much uncertainty regarding the cumulative effects of multiple SGI projects on hydrology and water quality at the watershed scale. To assess the cumulative effects of SGI, major cities across the mid-Atlantic were selected based on availability of SGI, water quality, and stream flow data. The impact of SGI was evaluated by comparing similar watersheds, with and without SGI or by assessing how long-term changes in SGI impact hydrologic and water quality metrics over time. Most mid-Atlantic cities have a goal of achieving 10-75% SGI by 2030. Of these cites, Washington D.C. currently has the highest density of SGI (15.5%), while Philadelphia, PA and New York, NY have the lowest (0.14% and 0.28%, respectively). When comparing watersheds of similar size and percent impervious surface cover, watersheds with lower amounts of SGI, on average, show up to 40% greater annual total nitrogen and 75% greater total phosphorus loads and show flashier hydrology (as indicated by 35% greater average peak discharge, 26% more peak discharge events per year, and 21% higher peak-to-volume ratio) compared to watersheds with higher amounts of SGI. However, for cities with combined sewer systems (e.g. Washington, D.C. and Philadelphia, PA), there was no relationship between the level of combined sewer overflows (CSOs) and the amount of SGI, indicating the level of SGI may not yet be sufficient to reduce CSOs as intended. When comparing individual watersheds over time, increases in SGI show no significant effect on the long-term trends in nutrient loads or hydrologic variables, potentially being obscured by the larger effect of interannual variability.
PLOT3D/AMES, UNIX SUPERCOMPUTER AND SGI IRIS VERSION (WITHOUT TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. In addition to providing the advantages of performing complex calculations on a supercomputer, the Supercomputer/IRIS implementation of PLOT3D offers advanced 3-D, view manipulation, and animation capabilities. Shading and hidden line/surface removal can be used to enhance depth perception and other aspects of the graphical displays. A mouse can be used to translate, rotate, or zoom in on views. Files for several types of output can be produced. Two animation options are available. Simple animation sequences can be created on the IRIS, or,if an appropriately modified version of ARCGRAPH (ARC-12350) is accesible on the supercomputer, files can be created for use in GAS (Graphics Animation System, ARC-12379), an IRIS program which offers more complex rendering and animation capabilities and options for recording images to digital disk, video tape, or 16-mm film. The version 3.6b+ Supercomputer/IRIS implementations of PLOT3D (ARC-12779) and PLOT3D/TURB3D (ARC-12784) are suitable for use on CRAY 2/UNICOS, CONVEX, and ALLIANT computers with a remote Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D workstation. These programs are distributed on .25 inch magnetic tape cartridges in IRIS TAR format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: (1) Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D workstations (ARC-12783, ARC-12782); (2) VAX computers running VMS Version 5.0 and DISSPLA Version 11.0 (ARC12777, ARC-12781); (3) generic UNIX and DISSPLA Version 11.0 (ARC-12788, ARC-12778); and (4) Apollo computers running UNIX and GMR3D Version 2.0 (ARC-12789, ARC-12785 - which have no capabilities to put text on plots). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo, DN10000, and GMR3D are trademarks of Hewlett-Packard, Incorporated. System V is a trademark of Bell Labs, Incorporated. BSD4.3 is a trademark of the University of California at Berkeley. UNIX is a registered trademark of AT&T.
PLOT3D/AMES, UNIX SUPERCOMPUTER AND SGI IRIS VERSION (WITH TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. In addition to providing the advantages of performing complex calculations on a supercomputer, the Supercomputer/IRIS implementation of PLOT3D offers advanced 3-D, view manipulation, and animation capabilities. Shading and hidden line/surface removal can be used to enhance depth perception and other aspects of the graphical displays. A mouse can be used to translate, rotate, or zoom in on views. Files for several types of output can be produced. Two animation options are available. Simple animation sequences can be created on the IRIS, or,if an appropriately modified version of ARCGRAPH (ARC-12350) is accesible on the supercomputer, files can be created for use in GAS (Graphics Animation System, ARC-12379), an IRIS program which offers more complex rendering and animation capabilities and options for recording images to digital disk, video tape, or 16-mm film. The version 3.6b+ Supercomputer/IRIS implementations of PLOT3D (ARC-12779) and PLOT3D/TURB3D (ARC-12784) are suitable for use on CRAY 2/UNICOS, CONVEX, and ALLIANT computers with a remote Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D workstation. These programs are distributed on .25 inch magnetic tape cartridges in IRIS TAR format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: (1) Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D workstations (ARC-12783, ARC-12782); (2) VAX computers running VMS Version 5.0 and DISSPLA Version 11.0 (ARC12777, ARC-12781); (3) generic UNIX and DISSPLA Version 11.0 (ARC-12788, ARC-12778); and (4) Apollo computers running UNIX and GMR3D Version 2.0 (ARC-12789, ARC-12785 - which have no capabilities to put text on plots). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo, DN10000, and GMR3D are trademarks of Hewlett-Packard, Incorporated. System V is a trademark of Bell Labs, Incorporated. BSD4.3 is a trademark of the University of California at Berkeley. UNIX is a registered trademark of AT&T.
Sorensen, Jacob R; Fuqua, Jordan D; Deyhle, Michael R; Parmley, Jacob; Skousen, Caitlin; Hancock, Chad; Parcell, Allen C; Hyldahl, Robert D
2018-01-01
Recent studies have highlighted the JAK/STAT signaling pathway in the regulation of muscle satellite cell behavior. Herein we report preclinical studies designed to characterize the effects of a novel JAK/STAT inhibitor on plantar flexor skeletal muscle function, morphology, and satellite cell content. The compound, SGI-1252, was administered orally (400mg/kg) in a 10% dextrose solution to wild type mice (n = 6) 3 times per week for 8 weeks. A control group (n = 6) received only the dextrose solution. SGI-1252 was well tolerated, as animals displayed similar weight gain over the 8-week treatment period. Following treatment, fatigue in the gastrocnemius-soleus-plantaris complex was greater in the SGI-1252 mice during a 300 second tetanic contraction bout (p = 0.035), though both the rate of fatigue and maximal force production were similar. SGI-1252 treated mice had increased type II myofiber cross-sectional area (1434.8 ± 225.4 vs 1754.7 ± 138.5 μm2), along with an increase in wet muscle mass (125.45 ± 5.46 vs 139.6 ± 12.34 mg, p = 0.032) of the gastrocnemius relative to vehicle treated mice. SGI-1252 treatment reduced gastrocnemius STAT3 phosphorylation 53% (94.79 ± 45.9 vs 44.5 ± 6.1 MFI) and significantly increased the concentration of Pax7+ satellite cells (2589.2 ± 105.5 vs 2859.4 ± 177.5 SC/mm3) in the gastrocnemius. SGI-1252 treatment suppressed MyoD (p = 0.013) and Myogenin (p<0.0001) expression in human primary myoblasts, resulting in reduced myogenic differentiation (p = 0.039). Orally delivered SGI-1252 was well tolerated, attenuates skeletal muscle STAT3 activity, and increases satellite cell content in mouse gastrocnemius muscle, likely by inhibiting myogenic progression.
Application of high-performance computing to numerical simulation of human movement
NASA Technical Reports Server (NTRS)
Anderson, F. C.; Ziegler, J. M.; Pandy, M. G.; Whalen, R. T.
1995-01-01
We have examined the feasibility of using massively-parallel and vector-processing supercomputers to solve large-scale optimization problems for human movement. Specifically, we compared the computational expense of determining the optimal controls for the single support phase of gait using a conventional serial machine (SGI Iris 4D25), a MIMD parallel machine (Intel iPSC/860), and a parallel-vector-processing machine (Cray Y-MP 8/864). With the human body modeled as a 14 degree-of-freedom linkage actuated by 46 musculotendinous units, computation of the optimal controls for gait could take up to 3 months of CPU time on the Iris. Both the Cray and the Intel are able to reduce this time to practical levels. The optimal solution for gait can be found with about 77 hours of CPU on the Cray and with about 88 hours of CPU on the Intel. Although the overall speeds of the Cray and the Intel were found to be similar, the unique capabilities of each machine are better suited to different portions of the computational algorithm used. The Intel was best suited to computing the derivatives of the performance criterion and the constraints whereas the Cray was best suited to parameter optimization of the controls. These results suggest that the ideal computer architecture for solving very large-scale optimal control problems is a hybrid system in which a vector-processing machine is integrated into the communication network of a MIMD parallel machine.
Yang, Qingshan; Chen, Lisa S.; Neelapu, Sattva S.; Miranda, Roberto N.; Medeiros, L. Jeffrey
2012-01-01
Proviral integration site for Moloney murine leukemia virus (Pim) kinases are serine/threonine/tyrosine kinases and oncoproteins that promote tumor progression. Three isoforms of Pim kinases have been identified and are known to phosphorylate numerous substrates, with regulatory functions in transcription, translation, cell cycle, and survival pathways. These kinases are involved in production, proliferation, and survival of normal B cells and are overexpressed in B-cell malignancies such as mantle cell lymphoma (MCL). SGI-1776 is a small mol-ecule and Pim kinase inhibitor with selectivity for Pim-1. We hypothesize that Pim kinase function can be inhibited by SGI-1776 in MCL and that inhibition of phosphorylation of downstream substrates will disrupt transcriptional, translational, and cell cycle processes and promote cell death. SGI-1776 treatment in 4 MCL cell lines resulted in apoptosis induction. Phosphorylation of transcription (c-Myc) and translation targets (4E-BP1), tested in Jeko-1 and Mino, was declined. Consistent with these data, Mcl-1 and cyclin D1 protein levels were decreased. Importantly, similar to cell line data, MCL primary cells but not normal cells showed similar inhibition of substrate phosphorylation and cytotoxicity from SGI-1776 treatment. Genetic knockdown of Pim-1/Pim-2 affected similar proteins in MCL cell lines. Collectively these data demonstrate Pim kinases as therapeutic targets in MCL. PMID:22955922
Yang, Qingshan; Chen, Lisa S; Neelapu, Sattva S; Miranda, Roberto N; Medeiros, L Jeffrey; Gandhi, Varsha
2012-10-25
Proviral integration site for Moloney murine leukemia virus (Pim) kinases are serine/threonine/tyrosine kinases and oncoproteins that promote tumor progression. Three isoforms of Pim kinases have been identified and are known to phosphorylate numerous substrates, with regulatory functions in transcription, translation, cell cycle, and survival pathways. These kinases are involved in production, proliferation, and survival of normal B cells and are overexpressed in B-cell malignancies such as mantle cell lymphoma (MCL). SGI-1776 is a small molecule and Pim kinase inhibitor with selectivity for Pim-1. We hypothesize that Pim kinase function can be inhibited by SGI-1776 in MCL and that inhibition of phosphorylation of downstream substrates will disrupt transcriptional, translational, and cell cycle processes and promote cell death. SGI-1776 treatment in 4 MCL cell lines resulted in apoptosis induction. Phosphorylation of transcription (c-Myc) and translation targets (4E-BP1), tested in Jeko-1 and Mino, was declined. Consistent with these data, Mcl-1 and cyclin D1 protein levels were decreased. Importantly, similar to cell line data, MCL primary cells but not normal cells showed similar inhibition of substrate phosphorylation and cytotoxicity from SGI-1776 treatment. Genetic knockdown of Pim-1/Pim-2 affected similar proteins in MCL cell lines. Collectively these data demonstrate Pim kinases as therapeutic targets in MCL.
Inertial Manifolds for Navier-Stokes Equations and Related Dynamical Systems
1991-05-31
Graphics IRIS (SGI). The RLE files for the animation are loaded to an Abekas and recorded to tape by Betacam . This computational work was done by using the...scripts and comments, are loaded to the Abekas-A60 digital image storage device, and then recorded to the Betacam BVW-75 analog tape recorder. Static...interfacing, huge data files are output to the Data Vault parallelly with little cost. In addition to the SGIs, Abekas, Betacam and Solitaire, the
Efficacy of Code Optimization on Cache-Based Processors
NASA Technical Reports Server (NTRS)
VanderWijngaart, Rob F.; Saphir, William C.; Chancellor, Marisa K. (Technical Monitor)
1997-01-01
In this paper a number of techniques for improving the cache performance of a representative piece of numerical software is presented. Target machines are popular processors from several vendors: MIPS R5000 (SGI Indy), MIPS R8000 (SGI PowerChallenge), MIPS R10000 (SGI Origin), DEC Alpha EV4 + EV5 (Cray T3D & T3E), IBM RS6000 (SP Wide-node), Intel PentiumPro (Ames' Whitney), Sun UltraSparc (NERSC's NOW). The optimizations all attempt to increase the locality of memory accesses. But they meet with rather varied and often counterintuitive success on the different computing platforms. We conclude that it may be genuinely impossible to obtain portable performance on the current generation of cache-based machines. At the least, it appears that the performance of modern commodity processors cannot be described with parameters defining the cache alone.
Watershed Scale Impacts of Stormwater Green Infrastructure ...
Despite the increasing use of urban stormwater green infrastructure (SGI), including detention ponds and rain gardens, few studies have quantified the cumulative effects of multiple SGI projects on hydrology and water quality at the watershed scale. To assess the effects of SGI, Baltimore County, MD, Montgomery County, MD, and Washington, DC, were selected based on the availability of data on SGI, water quality, and stream flow. The watershed scale impact of SGI was evaluated by assessing how increased spatial density of SGI correlates with stream hydrology and nitrogen exports over space and time. The most common SGI types were detention ponds (58%), followed by marshes (12%), sand filters (9%), wet ponds (7%), infiltration trenches (4%), and rain gardens (2%). When controlling for watersheds size and percent impervious surface cover, watersheds with greater amounts of SGI (>10% SGI) have 44% lower peak runoff, 26% less frequent runoff events, and 26% less variable runoff than watersheds with lower SGI. Watersheds with more SGI also show 44% less NO3− and 48% less total nitrogen exports compared to watersheds with minimal SGI. There was no significant reduction in combined sewer overflows in watersheds with greater SGI. Based on specific SGI types, infiltration trenches (R2 = 0.35) showed the strongest correlation with hydrologic metrics, likely due to their ability to attenuate flow, while bioretention (R2 = 0.19) and wet ponds (R2 = 0.12) showed stronger
NASA Astrophysics Data System (ADS)
Jaffe, P. R.; Pennino, M. J.; McDonald, R.
2016-12-01
Despite the increasing use of urban stormwater green infrastructure (SGI), including detention ponds and rain gardens, few studies have quantified the cumulative effects of multiple SGI projects on hydrology and water quality at the watershed scale. To assess the effects of SGI, Baltimore County, MD, Montgomery County, MD, and Washington, DC, were selected based on the availability of data on SGI, water quality, and stream flow. The watershed scale impact of SGI was evaluated by assessing how increased spatial density of SGI correlates with stream hydrology and nitrogen exports over space and time. The most common SGI types were detention ponds (58%), followed by marshes (12%), sand filters (9%), wet ponds (7%), infiltration trenches (4%), and rain gardens (2%). When controlling for watersheds size and percent impervious surface cover, watersheds with greater amounts of SGI (>10% SGI) have 44% lower peak runoff, 26% less frequent runoff events, and 26% less variable runoff than watersheds with lower SGI. Watersheds with more SGI also show 44% less NO3- and 48% less total nitrogen exports compared to watersheds with minimal SGI. There was no significant reduction in combined sewer overflows in watersheds with greater SGI. Based on specific SGI types, infiltration trenches (R2 = 0.35) showed the strongest correlation with hydrologic metrics, likely due to their ability to attenuate flow, while bioretention (R2 = 0.19) and wet ponds (R2 = 0.12) showed stronger relationships with nitrogen compared to other SGI types, possibly due to greater denitrification in these sites. When comparing individual watersheds over time, increases in SGI corresponded to non-significant reductions in hydrologic flashiness and combined sewer overflows compared to watersheds with no change in SGI. This study shows that while implementation of SGI is ongoing, some regions are beginning to have enough SGI to see significant impacts on hydrology and water quality at the watershed scale.
Experiences from the National Institute of Nursing Research: Summer Genetics Institute 2004.
Whitt, Karen J
2005-02-01
The National Institute of Nursing Research (NINR) Summer Genetics Institute (SGI) prepares nurses with training in molecular genetics for use in clinical practice, research, and education. Experiences from the SGI 2004 are recounted. More than 35 genetic experts from National Institutes of Health and surrounding universities in Washington, D.C., provided lecture and laboratory experiences. The lecture portion of the SGI focused on the molecular aspect of genetics and the laboratory component included experiments designed to provide an understanding of genetic approaches for diagnostic and research purposes. The SGI prepares nurses with the genetic foundation to meet the healthcare challenges of the future.
Update the following IRIS chemical dose-response assessments: Barium (cancer, RfC), o-Cresol (RfD, cancer), carbon disulfied (RfD, RfC), 1,1-Dichloroethane (cancer), 2,4-Dimethylphenol (RfD), 1,4-Dibromobenzene (RfD), 1-chloro-1,1-difluroelfane (RfC, Acetyl chloride (cancer),2,4...
Batra, Vandana; Maris, John M.; Kang, Min H.; Reynolds, C. Patrick; Houghton, Peter J.; Alexander, Denise; Kolb, E. Anders; Gorlick, Richard; Keir, Stephen T.; Carol, Hernan; Lock, Richard; Billups, Catherine A.; Smith, Malcolm A.
2011-01-01
The PIM kinase inhibitor, SGI-1776, was tested against the PPTP in vitro (1.0 nM to 10 μM) and in vivo panels (148 mg/kg daily x 5 days for 3 weeks). SGI-1776 exhibited cytotoxic activity in vitro with a median relative IC50 of 3.1 μM. SGI-1776 induced significant differences in EFS distribution in vivo in 9 of 31 solid tumor xenografts and in 1 of 8 of the evaluable ALL xenografts. SGI-1776 induced tumor growth inhibition meeting criteria for intermediate EFS T/C activity in 1 of 39 evaluable models. In contrast, SGI-1776 induced complete responses of subcutaneous MV4;11 (B myeloid leukemia). PMID:22052829
Analytic Patch Configuration (APC) gateway version 1.0 user's guide
NASA Technical Reports Server (NTRS)
Bingel, Bradford D.
1990-01-01
The Analytic Patch Configuration (APC) is an interactive software tool which translates aircraft configuration geometry files from one format into another. This initial release of the APC Gateway accommodates six formats: the four accepted APC formats (89f, 89fd, 89u, and 89ud), the PATRAN 2.x phase 1 neutral file format, and the Integrated Aerodynamic Analysis System (IAAS) General Geometry (GG) format. Written in ANSI FORTRAN 77 and completely self-contained, the APC Gateway is very portable and was already installed on CDC/NOS, VAX/VMS, SUN, SGI/IRIS, CONVEX, and GRAY hosts.
Batra, Vandana; Maris, John M; Kang, Min H; Reynolds, C Patrick; Houghton, Peter J; Alexander, Denise; Kolb, E Anders; Gorlick, Richard; Keir, Stephen T; Carol, Hernan; Lock, Richard; Billups, Catherine A; Smith, Malcolm A
2012-10-01
The PIM kinase inhibitor, SGI-1776, was tested against the PPTP in vitro (1.0 nM-10 µM) and in vivo panels (148 mg/kg daily × 5 days for 3 weeks). SGI-1776 exhibited cytotoxic activity in vitro with a median relative IC(50) of 3.1 µM. SGI-1776 induced significant differences in EFS distribution in vivo in 9 of 31 solid tumor xenografts and in 1 of 8 of the evaluable ALL xenografts. SGI-1776 induced tumor growth inhibition meeting criteria for intermediate EFS T/C activity in 1 of 39 evaluable models. In contrast, SGI-1776 induced complete responses of subcutaneous MV4;11 (B myeloid leukemia). Copyright © 2011 Wiley Periodicals, Inc.
Mechanisms of cytotoxicity to Pim kinase inhibitor, SGI-1776, in acute myeloid leukemia.
Chen, Lisa S; Redkar, Sanjeev; Taverna, Pietro; Cortes, Jorge E; Gandhi, Varsha
2011-07-21
Pim kinases are Ser/Thr kinases with multiple substrates that affect survival pathways. These proteins are overexpressed in acute myeloid leukemia (AML) blasts and we hypothesized that Pim kinase inhibition would affect AML cell survival. Imidazo[1,2-b]pyridazine compound, SGI-1776 inhibits Pim-1, Pim-2 and Pim-3, and was evaluated in AML-cell line, -xenograft model, and -primary blasts. Treatment of AML cells with SGI-1776 results in a concentration-dependent induction of apoptosis and we investigated its effect on Pim kinase functions. Phosphorylation of traditional Pim kinase targets, c-Myc(Ser62) and 4E-BP1 (Thr36/Thr47), were both decreased in actively cycling AML cell lines MV-4-11, MOLM-13 and OCI-AML-3. Levels of antiapoptotic proteins Bcl-2, Bcl-x(L), XIAP, and proapoptotic Bak and Bax were unchanged; however, a significant reduction in Mcl-1 was observed. This was correlated with inhibition of global RNA and protein synthesis and MCL-1 transcript decline after SGI-1776 treatment. These data suggest that SGI-1776 mechanism in AML involves Mcl-1 protein reduction. Consistent with cell line data, xenograft model studies with mice bearing MV-4-11 tumors showed efficacy with SGI-1776. Importantly, SGI-1776 was also cytotoxic in AML primary cells, irrespective of FLT3 mutation status and resulted in Mcl-1 protein decline. Pim kinase inhibition may be a new strategy for AML treatment.
Mechanisms of cytotoxicity to Pim kinase inhibitor, SGI-1776, in acute myeloid leukemia
Chen, Lisa S.; Redkar, Sanjeev; Taverna, Pietro; Cortes, Jorge E.
2011-01-01
Pim kinases are Ser/Thr kinases with multiple substrates that affect survival pathways. These proteins are overexpressed in acute myeloid leukemia (AML) blasts and we hypothesized that Pim kinase inhibition would affect AML cell survival. Imidazo[1,2-b]pyridazine compound, SGI-1776 inhibits Pim-1, Pim-2 and Pim-3, and was evaluated in AML-cell line, -xenograft model, and -primary blasts. Treatment of AML cells with SGI-1776 results in a concentration-dependent induction of apoptosis and we investigated its effect on Pim kinase functions. Phosphorylation of traditional Pim kinase targets, c-Myc(Ser62) and 4E-BP1 (Thr36/Thr47), were both decreased in actively cycling AML cell lines MV-4-11, MOLM-13 and OCI-AML-3. Levels of antiapoptotic proteins Bcl-2, Bcl-xL, XIAP, and proapoptotic Bak and Bax were unchanged; however, a significant reduction in Mcl-1 was observed. This was correlated with inhibition of global RNA and protein synthesis and MCL-1 transcript decline after SGI-1776 treatment. These data suggest that SGI-1776 mechanism in AML involves Mcl-1 protein reduction. Consistent with cell line data, xenograft model studies with mice bearing MV-4-11 tumors showed efficacy with SGI-1776. Importantly, SGI-1776 was also cytotoxic in AML primary cells, irrespective of FLT3 mutation status and resulted in Mcl-1 protein decline. Pim kinase inhibition may be a new strategy for AML treatment. PMID:21628411
NAS Parallel Benchmark Results 11-96. 1.0
NASA Technical Reports Server (NTRS)
Bailey, David H.; Bailey, David; Chancellor, Marisa K. (Technical Monitor)
1997-01-01
The NAS Parallel Benchmarks have been developed at NASA Ames Research Center to study the performance of parallel supercomputers. The eight benchmark problems are specified in a "pencil and paper" fashion. In other words, the complete details of the problem to be solved are given in a technical document, and except for a few restrictions, benchmarkers are free to select the language constructs and implementation techniques best suited for a particular system. These results represent the best results that have been reported to us by the vendors for the specific 3 systems listed. In this report, we present new NPB (Version 1.0) performance results for the following systems: DEC Alpha Server 8400 5/440, Fujitsu VPP Series (VX, VPP300, and VPP700), HP/Convex Exemplar SPP2000, IBM RS/6000 SP P2SC node (120 MHz), NEC SX-4/32, SGI/CRAY T3E, SGI Origin200, and SGI Origin2000. We also report High Performance Fortran (HPF) based NPB results for IBM SP2 Wide Nodes, HP/Convex Exemplar SPP2000, and SGI/CRAY T3D. These results have been submitted by Applied Parallel Research (APR) and Portland Group Inc. (PGI). We also present sustained performance per dollar for Class B LU, SP and BT benchmarks.
Xie, Jing; Bai, Jun
2014-07-01
To investigate the antitumor effect of SGI-1776 on human ovarian cancer HO-8910 cells and its molecular mechanism. HO-8910 cells were cultured in vitro, and the proliferation inhibitory effects of SGI- 1776 were determined by MTT assay and colony formation assay. The effect of SGI-1776 on the distribution of cell cycle phase was observed by flow cytometry with propidium iodide (PI) staining. The inhibition rate of migration and invasion were valued by transwell cell assay. Multiple molecular techniques, such as ELISA, Western blot, siRNA and cDNA transfection were used to explore the molecular mechanism. SGI-1776 presented dramatic anti-tumor activity against HO-8910 cells in vitro, inhibited the cells proliferation and colony formation, and attenuated the migration and invasion in a dosedependent manner, accompanied by cell cycle arrest in G1 phase. SGI-1776 caused the proliferation inhibition with concomitant decrease in Pim-1 kinase activity, down-regulated the expression of Pim-1 protein and and its downstream genes, such as CDK6, pCDK6, CDK4, pCDK4, CDK2 and pCDK2, and increased the expression of P21 and P27. Down-regulation expression of Pim-1 by siRNA followed SGI-1776 treatment resulted in enhanced cell proliferation inhibition rate and attenuated migration/invasion. Up-regulation of Pim-1 by cDNA transfection attenuated SGI- 1776-induced cell proliferation inhibition and its migration/invasion. Pim-1 mediates the biological effect of SGI-1776 in human ovarian cancer HO-8910 cells, suggesting Pim-1 might be a novel target for human ovarian cancer.
2,4-Dichlorophenoxyacetic acid (2,4-D)
Integrated Risk Information System (IRIS)
2,4 - Dichlorophenoxyacetic acid ( 2,4 - D ) ; CASRN 94 - 75 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Asses
Program Helps Decompose Complex Design Systems
NASA Technical Reports Server (NTRS)
Rogers, James L., Jr.; Hall, Laura E.
1995-01-01
DeMAID (Design Manager's Aid for Intelligent Decomposition) computer program is knowledge-based software system for ordering sequence of modules and identifying possible multilevel structure for design problems such as large platforms in outer space. Groups modular subsystems on basis of interactions among them. Saves considerable amount of money and time in total design process, particularly in new design problem in which order of modules has not been defined. Originally written for design problems, also applicable to problems containing modules (processes) that take inputs and generate outputs. Available in three machine versions: Macintosh written in Symantec's Think C 3.01, Sun, and SGI IRIS in C language.
Stability, Entrapment and Variant Formation of Salmonella Genomic Island 1
Kiss, János; Nagy, Béla; Olasz, Ferenc
2012-01-01
Background The Salmonella genomic island 1 (SGI1) is a 42.4 kb integrative mobilizable element containing several antibiotic resistance determinants embedded in a complex integron segment In104. The numerous SGI1 variants identified so far, differ mainly in this segment and the explanations of their emergence were mostly based on comparative structure analyses. Here we provide experimental studies on the stability, entrapment and variant formation of this peculiar gene cluster originally found in S. Typhimurium. Methodology/Principal Findings Segregation and conjugation tests and various molecular techniques were used to detect the emerging SGI1 variants in Salmonella populations of 17 Salmonella enterica serovar Typhimurium DT104 isolates from Hungary. The SGI1s in these isolates proved to be fully competent in excision, conjugal transfer by the IncA/C helper plasmid R55, and integration into the E. coli chromosome. A trap vector has been constructed and successfully applied to capture the island on a plasmid. Monitoring of segregation of SGI1 indicated high stability of the island. SGI1-free segregants did not accumulate during long-term propagation, but several SGI1 variants could be obtained. Most of them appeared to be identical to SGI1-B and SGI1-C, but two new variants caused by deletions via a short-homology-dependent recombination process have also been detected. We have also noticed that the presence of the conjugation helper plasmid increased the formation of these deletion variants considerably. Conclusions/Significance Despite that excision of SGI1 from the chromosome was proven in SGI1+ Salmonella populations, its complete loss could not be observed. On the other hand, we demonstrated that several variants, among them two newly identified ones, arose with detectable frequencies in these populations in a short timescale and their formation was promoted by the helper plasmid. This reflects that IncA/C helper plasmids are not only involved in the horizontal spreading of SGI1, but may also contribute to its evolution. PMID:22384263
Visual flow scene effects on the somatogravic illusion in non-pilots.
Eriksson, Lars; von Hofsten, Claes; Tribukait, Arne; Eiken, Ola; Andersson, Peter; Hedström, Johan
2008-09-01
The somatogravic illusion (SGI) is easily broken when the pilot looks out the aircraft window during daylight flight, but it has proven difficult to break or even reduce the SGI in non-pilots in simulators using synthetic visual scenes. Could visual-flow scenes that accommodate compensatory head movement reduce the SGI in naive subjects? We investigated the effects of visual cues on the SGI induced by a human centrifuge. The subject was equipped with a head-tracked, head-mounted display (HMD) and was seated in a fixed gondola facing the center of rotation. The angular velocity of the centrifuge increased from near zero until a 0.57-G centripetal acceleration was attained, resulting in a tilt of the gravitoinertial force vector, corresponding to a pitch-up of 30 degrees. The subject indicated perceived horizontal continuously by means of a manual adjustable-plate system. We performed two experiments with within-subjects designs. In Experiment 1, the subjects (N = 13) viewed a darkened HMD and a presentation of simple visual flow beneath a horizon. In Experiment 2, the subjects (N = 12) viewed a darkened HMD, a scene including symbology superimposed on simple visual flow and horizon, and this scene without visual flow (static). In Experiment 1, visual flow reduced the SGI from 12.4 +/- 1.4 degrees (mean +/- SE) to 8.7 +/- 1.5 degrees. In Experiment 2, the SGI was smaller in the visual flow condition (9.3 +/- 1.8 degrees) than with the static scene (13.3 +/- 1.7 degrees) and without HMD presentation (14.5 +/- 2.3 degrees), respectively. It is possible to reduce the SGI in non-pilots by means of a synthetic horizon and simple visual flow conveyed by a head-tracked HMD. This may reflect the power of a more intuitive display for reducing the SGI.
The Changing Landscape of Chemical Toxicity Values and Challenges Presented with Trichloroethylene
2012-12-11
become Risk Management Actions (RMAs) BUILDING STRONG® IRIS Documents Reviewed by DoD Services Benzo(a)pyrene Trimethylbenzenes Dioxin ...4 BUILDING STRONG® Other Chemicals of DoD Interest Undergoing IRIS Reassessment 1,4-Dioxane Dioxin (cancer) RDX Arsenic
DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (SGI IRIS VERSION)
NASA Technical Reports Server (NTRS)
Rogers, J. L.
1994-01-01
Many engineering systems are large and multi-disciplinary. Before the design of new complex systems such as large space platforms can begin, the possible interactions among subsystems and their parts must be determined. Once this is completed the proposed system can be decomposed to identify its hierarchical structure. DeMAID (A Design Manager's Aid for Intelligent Decomposition) is a knowledge-based system for ordering the sequence of modules and identifying a possible multilevel structure for the design problem. DeMAID displays the modules in an N x N matrix format (called a design structure matrix) where a module is any process that requires input and generates an output. (Modules which generate an output but do not require an input, such as an initialization process, are also acceptable.) Although DeMAID requires an investment of time to generate and refine the list of modules for input, it could save a considerable amount of money and time in the total design process, particularly in new design problems where the ordering of the modules has not been defined. The decomposition of a complex design system into subsystems requires the judgement of the design manager. DeMAID reorders and groups the modules based on the links (interactions) among the modules, helping the design manager make decomposition decisions early in the design cycle. The modules are grouped into circuits (the subsystems) and displayed in an N x N matrix format. Feedback links, which indicate an iterative process, are minimized and only occur within a subsystem. Since there are no feedback links among the circuits, the circuits can be displayed in a multilevel format. Thus, a large amount of information is reduced to one or two displays which are stored for later retrieval and modification. The design manager and leaders of the design teams then have a visual display of the design problem and the intricate interactions among the different modules. The design manager could save a substantial amount of time if circuits on the same level of the multilevel structure are executed in parallel. DeMAID estimates the time savings based on the number of available processors. In addition to decomposing the system into subsystems, DeMAID examines the dependencies of a problem with independent variables and dependant functions. A dependency matrix is created to show the relationship. DeMAID is based on knowledge base techniques to provide flexibility and ease in adding new capabilities. Although DeMAID was originally written for design problems, it has proven to be very general in solving any problem which contains modules (processes) which take an input and generate an output. For example, one group is applying DeMAID to gain understanding of the data flow of a very large computer program. In this example, the modules are the subroutines of the program. The design manager begins the design of a system by determining the level of modules which need to be ordered. The level is the "granularity" of the problem. For example, the design manager may wish to examine disciplines (a coarse model), analysis programs, or the data level (a fine model). Once the system is divided into these modules, each module's input and output is determined, creating a data file for input to the main program. DeMAID is executed through a system of menus. The user has the choice to plan, schedule, display the N x N matrix, display the multilevel organization, or examine the dependency matrix. The main program calls a subroutine which reads a rule file and a data file, asserts facts into the knowledge base, and executes the inference engine of the artificial intelligence/expert systems program, CLIPS (C Language Integrated Production System). To determine the effects of changes in the design process, DeMAID includes a trace effects feature. There are two methods available to trace the effects of a change in the design process. The first method traces forward through the outputs to determine the effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.
Transferable Output ASCII Data (TOAD) editor version 1.0 user's guide
NASA Technical Reports Server (NTRS)
Bingel, Bradford D.; Shea, Anne L.; Hofler, Alicia S.
1991-01-01
The Transferable Output ASCII Data (TOAD) editor is an interactive software tool for manipulating the contents of TOAD files. The TOAD editor is specifically designed to work with tabular data. Selected subsets of data may be displayed to the user's screen, sorted, exchanged, duplicated, removed, replaced, inserted, or transferred to and from external files. It also offers a number of useful features including on-line help, macros, a command history, an 'undo' option, variables, and a full compliment of mathematical functions and conversion factors. Written in ANSI FORTRAN 77 and completely self-contained, the TOAD editor is very portable and has already been installed on SUN, SGI/IRIS, and CONVEX hosts.
Ghosh, Sudipta; Couper, Terry A; Lamoureux, Ecosse; Jhanji, Vishal; Taylor, Hugh R; Vajpayee, Rasik B
2008-02-01
To evaluate the visual and refractive outcomes of wavefront-guided laser in situ keratomileusis (LASIK) using an iris recognition system for the correction of myopic astigmatism. Centre for Eye Research Australia, Melbourne Excimer Laser Research Group, and Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia. A comparative analysis of wavefront-guided LASIK was performed with an iris recognition system (iris recognition group) and without iris recognition (control group). The main parameters were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity, amount of residual cylinder, manifest spherical equivalent (SE), and the index of success using the Alpins method of astigmatism analysis 1 and 3 months postoperatively. A P value less than 0.05 was considered statistically significant. Preoperatively, the mean SE was -4.32 diopters (D) +/- 1.59 (SD) in the iris recognition group (100 eyes) and -4.55 +/- 1.87 D in the control group (98 eyes) (P = .84). At 3 months, the mean SE was -0.05 +/- 0.21 D and -0.20 +/- 0.40 D, respectively (P = .001), and an SE within +/-0.50 D of emmetropia was achieved in 92.0% and 85.7% of eyes, respectively (P = .07). At 3 months, the UCVA was 20/20 or better in 90.0% and 76.5% of eyes, respectively. A statistically significant difference in the amount of astigmatic correction was seen between the 2 groups (P = .00 and P = .01 at 1 and 3 months, respectively). The index of success was 98.0% in the iris recognition group and 81.6% in the control group (P = .03). Iris recognition software may achieve better visual and refractive outcomes in wavefront-guided LASIK for myopic astigmatism.
Pennino, Michael J; McDonald, Rob I; Jaffe, Peter R
2016-09-15
Stormwater green infrastructure (SGI), including rain gardens, detention ponds, bioswales, and green roofs, is being implemented in cities across the globe to reduce flooding, combined sewer overflows, and pollutant transport to streams and rivers. Despite the increasing use of urban SGI, few studies have quantified the cumulative effects of multiple SGI projects on hydrology and water quality at the watershed scale. To assess the effects of SGI, Washington, DC, Montgomery County, MD, and Baltimore County, MD, were selected based on the availability of data on SGI, water quality, and stream flow. The cumulative impact of SGI was evaluated over space and time by comparing watersheds with and without SGI, and by assessing how long-term changes in SGI impact hydrologic and water quality metrics over time. Most Mid-Atlantic municipalities have a goal of achieving 10-20% of the landscape drain runoff through SGI by 2030. Of these areas, Washington, DC currently has the greatest amount of SGI (12.7% of the landscape drained through SGI), while Baltimore County has the lowest (7.9%). When controlling for watersheds size and percent impervious surface cover, watersheds with greater amounts of SGI have less flashy hydrology, with 44% lower peak runoff, 26% less frequent runoff events, and 26% less variable runoff. Watersheds with more SGI also show 44% less NO3(-) and 48% less total nitrogen exports compared to watersheds with minimal SGI. There was no significant reduction in phosphorus exports or combined sewer overflows in watersheds with greater SGI. When comparing individual watersheds over time, increases in SGI corresponded to non-significant reductions in hydrologic flashiness compared to watersheds with no change in SGI. While the implementation of SGI is somewhat in its infancy in some regions, cities are beginning to have a scale of SGI where there are statistically significant differences in hydrologic patterns and water quality. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Le Hello, Simon; Weill, François-Xavier; Guibert, Véronique; Praud, Karine; Cloeckaert, Axel
2012-01-01
Salmonella genomic island 1 (SGI1) is a 43-kb integrative mobilizable element that harbors a great diversity of multidrug resistance gene clusters described in numerous Salmonella enterica serovars and also in Proteus mirabilis. The majority of SGI1 variants contain an In104-derivative complex class 1 integron inserted between resolvase gene res and open reading frame (ORF) S044 in SGI1. Recently, the international spread of ciprofloxacin-resistant S. enterica serovar Kentucky sequence type 198 (ST198) containing SGI1-K variants has been reported. A retrospective study was undertaken to characterize ST198 S. Kentucky strains isolated before the spread of the epidemic ST198-SGI1-K population in Africa and the Middle East. Here, we characterized 12 ST198 S. Kentucky strains isolated between 1969 and 1999, mainly from humans returning from Southeast Asia (n = 10 strains) or Israel (n = 1 strain) or from meat in Egypt (n = 1 strain). All these ST198 S. Kentucky strains did not belong to the XbaI pulsotype X1 associated with the African epidemic clone but to pulsotype X2. SGI1-J subgroup variants containing different complex integrons with a partial transposition module and inserted within ORF S023 of SGI1 were detected in six strains. The SGI1-J4 variant containing a partially deleted class 1 integron and thus showing a narrow resistance phenotype to sulfonamides was identified in two epidemiologically unrelated strains from Indonesia. The four remaining strains harbored a novel SGI1-J variant, named SGI1-J6, which contained aadA2, floR2, tetR(G)-tetA(G), and sul1 resistance genes within its complex integron. Moreover, in all these S. Kentucky isolates, a novel insertion sequence related to the IS630 family and named ISSen5 was found inserted upstream of the SGI1 complex integron in ORF S023. Thus, two subpopulations of S. Kentucky ST198 independently and exclusively acquired the SGI1 during the 1980s and 1990s. Unlike the ST198-X1 African epidemic subpopulation, the ST198-X2 subpopulation mainly from Asia harbors variants of the SGI1-J subgroup that are encountered mainly in the Far East, as previously described for S. enterica serovars Emek and Virchow. PMID:22802251
Le Hello, Simon; Weill, François-Xavier; Guibert, Véronique; Praud, Karine; Cloeckaert, Axel; Doublet, Benoît
2012-10-01
Salmonella genomic island 1 (SGI1) is a 43-kb integrative mobilizable element that harbors a great diversity of multidrug resistance gene clusters described in numerous Salmonella enterica serovars and also in Proteus mirabilis. The majority of SGI1 variants contain an In104-derivative complex class 1 integron inserted between resolvase gene res and open reading frame (ORF) S044 in SGI1. Recently, the international spread of ciprofloxacin-resistant S. enterica serovar Kentucky sequence type 198 (ST198) containing SGI1-K variants has been reported. A retrospective study was undertaken to characterize ST198 S. Kentucky strains isolated before the spread of the epidemic ST198-SGI1-K population in Africa and the Middle East. Here, we characterized 12 ST198 S. Kentucky strains isolated between 1969 and 1999, mainly from humans returning from Southeast Asia (n = 10 strains) or Israel (n = 1 strain) or from meat in Egypt (n = 1 strain). All these ST198 S. Kentucky strains did not belong to the XbaI pulsotype X1 associated with the African epidemic clone but to pulsotype X2. SGI1-J subgroup variants containing different complex integrons with a partial transposition module and inserted within ORF S023 of SGI1 were detected in six strains. The SGI1-J4 variant containing a partially deleted class 1 integron and thus showing a narrow resistance phenotype to sulfonamides was identified in two epidemiologically unrelated strains from Indonesia. The four remaining strains harbored a novel SGI1-J variant, named SGI1-J6, which contained aadA2, floR2, tetR(G)-tetA(G), and sul1 resistance genes within its complex integron. Moreover, in all these S. Kentucky isolates, a novel insertion sequence related to the IS630 family and named ISSen5 was found inserted upstream of the SGI1 complex integron in ORF S023. Thus, two subpopulations of S. Kentucky ST198 independently and exclusively acquired the SGI1 during the 1980s and 1990s. Unlike the ST198-X1 African epidemic subpopulation, the ST198-X2 subpopulation mainly from Asia harbors variants of the SGI1-J subgroup that are encountered mainly in the Far East, as previously described for S. enterica serovars Emek and Virchow.
GVS - GENERAL VISUALIZATION SYSTEM
NASA Technical Reports Server (NTRS)
Keith, S. R.
1994-01-01
The primary purpose of GVS (General Visualization System) is to support scientific visualization of data output by the panel method PMARC_12 (inventory number ARC-13362) on the Silicon Graphics Iris computer. GVS allows the user to view PMARC geometries and wakes as wire frames or as light shaded objects. Additionally, geometries can be color shaded according to phenomena such as pressure coefficient or velocity. Screen objects can be interactively translated and/or rotated to permit easy viewing. Keyframe animation is also available for studying unsteady cases. The purpose of scientific visualization is to allow the investigator to gain insight into the phenomena they are examining, therefore GVS emphasizes analysis, not artistic quality. GVS uses existing IRIX 4.0 image processing tools to allow for conversion of SGI RGB files to other formats. GVS is a self-contained program which contains all the necessary interfaces to control interaction with PMARC data. This includes 1) the GVS Tool Box, which supports color histogram analysis, lighting control, rendering control, animation, and positioning, 2) GVS on-line help, which allows the user to access control elements and get information about each control simultaneously, and 3) a limited set of basic GVS data conversion filters, which allows for the display of data requiring simpler data formats. Specialized controls for handling PMARC data include animation and wakes, and visualization of off-body scan volumes. GVS is written in C-language for use on SGI Iris series computers running IRIX. It requires 28Mb of RAM for execution. Two separate hardcopy documents are available for GVS. The basic document price for ARC-13361 includes only the GVS User's Manual, which outlines major features of the program and provides a tutorial on using GVS with PMARC_12 data. Programmers interested in modifying GVS for use with data in formats other than PMARC_12 format may purchase a copy of the draft GVS 3.1 Software Maintenance Manual separately, if desired, for $26. An electronic copy of the User's Manual, in Macintosh Word format, is included on the distribution media. Purchasers of GVS are advised that changes and extensions to GVS are made at their own risk. In addition, GVS includes an on-line help system and sample input files. The standard distribution medium for GVS is a .25 inch streaming magnetic tape cartridge in IRIX tar format. GVS was developed in 1992.
Secondary metabolites from endemic species Iris adriatica Trinajstić ex Mitić (Iridaceae).
Bukvički, Danka; Novaković, Miroslav; Ab Ghani, Nurunajah; Marin, Petar D; Asakawa, Yoshinori
2018-08-01
This manuscript describes the first detailed chemical investigation of endemic species Iris adriatica, including isolation and structure elucidation. Chemical analyses of the rhizome CH 2 Cl 2 /MeOH (2:1) extract revealed fourteen secondary metabolites, mainly isoflavonoids. Among isoflavonoids, two groups have been found: nigricin-type and tectorigenin-type. Dominant group of the isolated compounds has been nigricin-type isoflavones: nigricin, nigricin-4'-(1-O-β-D-glucopyranoside) and nigricin-4'-(1-O-β-D-glucopyranosyl (1-6)-β-D-glucopyranoside) with 2.5, 10 and 1% of the total extract, respectively. Irisxanthone - xanthone C-glucoside, β-sitosterol, benzophenone and one of its derivatives have also been found. Nigricin-type isoflavonoids and irisxanthone can be considered as possible chemotaxonomic markers for I. adriatica. 5,3',5'-Trimethoxy-6,7-methylenedioxyisoflavone-4'-(1-O-β-D-glucopyranoside) and benzophenone have been isolated from Iris species for the first time.
BRCA1-IRIS regulates cyclin D1 expression in breast cancer cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakuci, Enkeleda; Mahner, Sven; DiRenzo, James
2006-10-01
The regulator of cell cycle progression, cyclin D1, is up-regulated in breast cancer cells; its expression is, in part, dependent on ER{alpha} signaling. However, many ER{alpha}-negative tumors and tumor cell lines (e.g., SKBR3) also show over-expression of cyclin D1. This suggests that, in addition to ER{alpha} signaling, cyclin D1 expression is under the control of other signaling pathways; these pathways may even be over-expressed in the ER{alpha}-negative cells. We previously noticed that both ER{alpha}-positive and -negative cell lines over-express BRCA1-IRIS mRNA and protein. Furthermore, the level of over-expression of BRCA1-IRIS in ER{alpha}-negative cell lines even exceeded its over-expression level inmore » ER{alpha}-positive cell lines. In this study, we show that: (1) BRCA1-IRIS forms complex with two of the nuclear receptor co-activators, namely, SRC1 and SRC3 (AIB1) in an ER{alpha}-independent manner. (2) BRCA1-IRIS alone, or in connection with co-activators, is recruited to the cyclin D1 promoter through its binding to c-Jun/AP1 complex; this binding activates the cyclin D1 expression. (3) Over-expression of BRCA1-IRIS in breast cells over-activates JNK/c-Jun; this leads to the induction of cyclin D1 expression and cellular proliferation. (4) BRCA1-IRIS activation of JNK/c-Jun/AP1 appears to account for this, because in cells that were depleted from BRCA1-IRIS, JNK remained inactive. However, depletion of SRC1 or SRC3 instead reduced c-Jun expression. Our data suggest that this novel signaling pathway links BRCA1-IRIS to cellular proliferation through c-Jun/AP1 nuclear pathway; finally, this culminates in the increased expression of the cyclin D1 gene.« less
Predicting story goodness performance from cognitive measures following traumatic brain injury.
Lê, Karen; Coelho, Carl; Mozeiko, Jennifer; Krueger, Frank; Grafman, Jordan
2012-05-01
This study examined the prediction of performance on measures of the Story Goodness Index (SGI; Lê, Coelho, Mozeiko, & Grafman, 2011) from executive function (EF) and memory measures following traumatic brain injury (TBI). It was hypothesized that EF and memory measures would significantly predict SGI outcomes. One hundred sixty-seven individuals with TBI participated in the study. Story retellings were analyzed using the SGI protocol. Three cognitive measures--Delis-Kaplan Executive Function System (D-KEFS; Delis, Kaplan, & Kramer, 2001) Sorting Test, Wechsler Memory Scale--Third Edition (WMS-III; Wechsler, 1997) Working Memory Primary Index (WMI), and WMS-III Immediate Memory Primary Index (IMI)--were entered into a multiple linear regression model for each discourse measure. Two sets of regression analyses were performed, the first with the Sorting Test as the first predictor and the second with it as the last. The first set of regression analyses identified the Sorting Test and IMI as the only significant predictors of performance on measures of the SGI. The second set identified all measures as significant predictors when evaluating each step of the regression function. The cognitive variables predicted performance on the SGI measures, although there were differences in the amount of explained variance. The results (a) suggest that storytelling ability draws on a number of underlying skills and (b) underscore the importance of using discrete cognitive tasks rather than broad cognitive indices to investigate the cognitive substrates of discourse.
Doublet, Benoît; Praud, Karine; Bertrand, Sophie; Collard, Jean-Marc; Weill, François-Xavier; Cloeckaert, Axel
2008-10-01
Salmonella genomic island 1 (SGI1) is an integrative mobilizable element that harbors a multidrug resistance (MDR) gene cluster. Since its identification in epidemic Salmonella enterica serovar Typhimurium DT104 strains, variant SGI1 MDR gene clusters conferring different MDR phenotypes have been identified in several S. enterica serovars and classified as SGI1-A to -O. A study was undertaken to characterize SGI1 from serovar Kentucky strains isolated from travelers returning from Africa. Several strains tested were found to contain the partially characterized variant SGI1-K, recently described in a serovar Kentucky strain isolated in Australia. This variant contained only one cassette array, aac(3)-Id-aadA7, and an adjacent mercury resistance module. Here, the uncharacterized part of SGI1-K was sequenced. Downstream of the mer module similar to that found in Tn21, a mosaic genetic structure was found, comprising (i) part of Tn1721 containing the tetracycline resistance genes tetR and tet(A); (ii) part of Tn5393 containing the streptomycin resistance genes strAB, IS1133, and a truncated tnpR gene; and (iii) a Tn3-like region containing the tnpR gene and the beta-lactamase bla(TEM-1) gene flanked by two IS26 elements in opposite orientations. The rightmost IS26 element was shown to be inserted into the S044 open reading frame of the SGI1 backbone. This variant MDR region was named SGI1-K1 according to the previously described variant SGI1-K. Other SGI1-K MDR regions due to different IS26 locations, inversion, and partial deletions were characterized and named SGI1-K2 to -K5. Two new SGI1 variants named SGI1-P1 and -P2 contained only the Tn3-like region comprising the beta-lactamase bla(TEM-1) gene flanked by the two IS26 elements inserted into the SGI1 backbone. Three other new variants harbored only one IS26 element inserted in place of the MDR region of SGI1 and were named SGI1-Q1 to -Q3. Thus, in serovar Kentucky, the SGI1 MDR region undergoes recombinational and insertional events of transposon and insertion sequences, resulting in a higher diversity of MDR gene clusters than previously reported and consequently a higher diversity of MDR phenotypes.
Modelling future changes to the stratospheric source gas injection of biogenic bromocarbons
NASA Astrophysics Data System (ADS)
Hossaini, R.; Chipperfield, M. P.; Dhomse, S.; Ordóñez, C.; Saiz-Lopez, A.; Abraham, N. L.; Archibald, A.; Braesicke, P.; Telford, P.; Warwick, N.; Yang, X.; Pyle, J.
2012-10-01
Simulations with a chemistry-climate model (CCM) show a future increase in the stratospheric source gas injection (SGI) of biogenic very short-lived substances (VSLS). For 2000, the modelled SGI of bromine from VSLS is ∼1.7 parts per trillion (pptv) and largest over the tropical West Pacific. For 2100, this increases to ∼2.0 and ∼2.7 pptv when the model is forced with Intergovernmental Panel on Climate Change (IPCC) representative concentration pathways (RCPs) 4.5 and 8.5. The increase is largely due to stronger tropical deep convection transporting more CHBr3 to the lower stratosphere. For CH2Br2, CHBr2Cl, CH2BrCl and CHBrCl2, changes to primary oxidant OH determines their SGI contribution. Under RCP 4.5 (moderate warming), OH increases in a warmer, more humid troposphere. Under RCP 8.5 (extreme warming) OH decreases significantly due to a large methane increase, allowing greater SGI of bromine from these VSLS. Potentially enhanced VSLS emissions in the future would further increase these estimates.
Remedial Investigation Addendum Report Data Item A009. Volume 4: Appendices I-Z
1993-12-01
Impatien~s capensis FACW Yellow Iris Iris pseudoacorus OBL Blueflag Iris Iris versicolor OBL 1 21 I NEW ENGLAND ENVIRONMENTAL, INC. Duckweed Lemna spp...small mammal community in the food web model. American woodcock (Scolopax minor ). This small bird is often j found in forested wetlands and forages...34Drinking Water and Health" Safe Drinking Water Committee, Washington, D.C. Thallium Thallium is a naturally occurring soft metal that is a minor
Permethrin resistance in Aedes albopictus (Diptera: Culicidae) and associated fitness costs.
Chan, Hiang Hao; Zairi, Jaal
2013-03-01
Insecticide resistance has become a serious issue in vector management programs. Information on insecticidal resistance and its associated mechanisms is important for successful insecticide resistance management. The selection of a colony of permethrin-resistant Aedes albopictus (Skuse) (Diptera: Culicidae), originating from Penang Island, Malaysia, yielded high larval-specific resistance to permethrin and cross-resistance to deltamethrin. Synergism assays showed that the major mechanism underlying this resistance involves cytochrome P450 monooxygenase. The resistance is autosomal, polygenically inherited and incompletely dominant (D = 0.26). Resistant larvae were reared under different conditions to assess the fitness costs. Under high larval density, larval development time of the resistant SGI strain was significantly longer than the susceptible VCRU strain. In both high- and low-density conditions SGI showed a lower rate of emergence and survival compared with the VCRU strain. Resistant larvae were more susceptible to predation by Toxorhynchites splendens (Wiedemann) (Diptera: Culicidae) larvae. The body size of SGI females reared under high-density conditions was larger compared with females of the susceptible strain. SGI females survived longer when starved than did VCRU females. The energy reserve upon eclosion was positively correlated with the size of the adults.
Biological Effects of the Pim Kinase Inhibitor, SGI-1776, in Multiple Myeloma
Cervantes-Gomez, Fabiola; Chen, Lisa S.; Orlowski, Robert Z.; Gandhi, Varsha
2013-01-01
Pim kinases are constitutively active serine/threonine/tyrosine kinases that are overexpressed in hematological malignancies such as multiple myeloma. Pim kinase substrates are involved in transcription, protein translation, cell proliferation, and apoptosis. SGI-1776 is a potent Pim kinase inhibitor that has proven to be cytotoxic to leukemia and lymphoma cells. Based on this background, we hypothesized that SGI-1776 treatment would result in myeloma cytotoxicity. To test this, myeloma cell lines and primary CD138+ cells from myeloma patients were treated with SGI-1776 in a dose- and time-dependent manner and effect on cell death and proliferation, induction of autophagy, as wells as changes in cell cycle profile were measured. SGI-1776 treatment resulted in limited apoptosis in cell lines (mean 30%) and CD138+ cells (<10%) as assessed by Annexin-V/PI. Limited effect was observed in cell cycle profile or growth in cell lines. However, DNA synthesis was decreased by 70% at 3 μM (all time points) in U266 though this was not observed in MM.1S. In accordance, immunoblot analyses revealed no change in transcription (c-Myc and H3), or apoptotic (Bad) proteins that are substrates of Pim kinases. In contrast, autophagy, as assessed by acridine orange staining, was induced with SGI-1776 treatment in both cell lines (U266 25-70%; MM.1S 8-52%) and CD138+ cells (19-21%). Immunoblot analyses of autophagy LC3b marker and translation initiation proteins (phospho p70S6K and 4E-BP1) corroborated autophagy induction. These data indicate that SGI-1776 treatment in myeloma cell lines and CD138+ myeloma cells elicits its deleterious effects through inhibition of translation and induction of autophagy. PMID:23988451
Biological effects of the Pim kinase inhibitor, SGI-1776, in multiple myeloma.
Cervantes-Gomez, Fabiola; Chen, Lisa S; Orlowski, Robert Z; Gandhi, Varsha
2013-09-01
Pim kinases are constitutively active serine/threonine/tyrosine kinases that are overexpressed in hematological malignancies such as multiple myeloma. Pim kinase substrates are involved in transcription, protein translation, cell proliferation, and apoptosis. SGI-1776 is a potent Pim kinase inhibitor that has proven to be cytotoxic to leukemia and lymphoma cells. Based on this background, we hypothesized that SGI-1776 treatment would result in myeloma cytotoxicity. To test this, myeloma cell lines and primary CD138(+) cells from myeloma patients were treated with SGI-1776 in a dose- and time-dependent manner, and effect on cell death and proliferation, induction of autophagy, and changes in cell cycle profile were measured. SGI-1776 treatment resulted in limited apoptosis in cell lines (mean 30%) and CD138(+) cells (< 10%) assessed using Annexin-V/propidium iodide. Limited effect was observed in cell cycle profile or growth in cell lines. However, DNA synthesis was decreased by 70% at 3 μM (all time points) in U266 though this was not observed in MM.1S. In accordance, immunoblot analyses revealed no change in transcription (c-Myc and H3), or apoptotic (Bad) proteins that are substrates of Pim kinases. In contrast, autophagy, assessed using acridine orange staining, was induced with SGI-1776 treatment in both cell lines (U266, 25%-70%; MM.1S, 8%-52%) and CD138(+) cells (19%-21%). Immunoblot analyses of the autophagy LC3b marker and translation initiation proteins (phospho-p70S6K and 4E-BP1) corroborated autophagy induction. These data indicate that SGI-1776 treatment in myeloma cell lines and CD138(+) myeloma cells elicits its deleterious effects through inhibition of translation and induction of autophagy. Copyright © 2013 Elsevier Inc. All rights reserved.
Lei, Chang-Wei; Zhang, An-Yun; Liu, Bi-Hui; Wang, Hong-Ning; Guan, Zhong-Bin; Xu, Chang-Wen; Xia, Qing-Qing; Cheng, Han; Zhang, Dong-Dong
2014-12-01
Six out of the 64 studied Proteus mirabilis isolates from 11 poultry farms in China contained Salmonella genomic island 1 (SGI1). PCR mapping showed that the complete nucleotide sequences of SGI1s ranged from 33.2 to 42.5 kb. Three novel variants, SGI1-W, SGI1-X, and SGI1-Y, have been characterized. Resistance genes lnuF, dfrA25, and qnrB2 were identified in SGI1 for the first time. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
2,2\\',3,3\\',4,4\\',5,5\\',6,6\\'-Decabromodiphenyl ether (BDE-209)
Integrated Risk Information System (IRIS)
EPA / 635 / R - 07 / 008F www.epa.gov / iris TOXICOLOGICAL REVIEW OF DECABROMODIPHENYL ETHER ( BDE - 209 ) ( CAS No . 1163 - 19 - 5 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) June 2008 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This d
Wang, Wei-qun; Zhang, Jin-song; Zhao, Xiao-jin
2011-10-01
To explore the postoperative visual acuity results of wavefront-guided LASIK with iris recognition for myopia or myopic astigmatism and the changes of higher-order aberrations and contrast sensitivity function (CSF). Series of prospective case studies, 158 eyes (85 cases) of myopia or myopic astigmatism were divided into two groups: one group underwent wavefront-guided LASIK with iris recognition (iris recognition group); another group underwent wavefront-guided LASIK treatment without iris recognition through the limbus maring point (non-iris recognition group). To comparative analyze the postoperative visual acuity, residual refraction, the RMS of higher-order aberrations and CSF of two groups. There was no statistical significance difference between two groups of the average uncorrected visual acuity (t = 0.039, 0.058, 0.898; P = 0.844, 0.810, 0.343), best corrected visual acuity (t = 0.320, 0.440, 1.515; P = 0.572, 0.507, 0.218), and residual refraction [spherical equivalent (t = 0.027, 0.215, 0.238; P = 0.869, 0.643, 0.626), spherical (t = 0.145, 0.117, 0.038; P = 0.704, 0.732, 0.845) and cylinder (t = 1.676, 1.936, 0.334; P = 0.195, 0.164, 0.563)] at postoperative 10 days, 1 month and 3 month. The security index of iris recognition group at postoperative 3 month was 1.06 and non-iris recognition group was 1.03; the efficacy index of iris recognition group is 1.01 and non-iris recognition group was 1.00. Postoperative 3 month iris recognition group 93.83% eyes and non-iris recognition group of 90.91% eyes spherical equivalent within ± 0.50 D (χ(2) = 0.479, P = 0.489), iris recognition group of 98.77% eyes and non-iris recognition group of 97.40% eyes spherical equivalent within ± 1.00 D (Fisher test, P = 0.613). There was no significance difference between the two groups of security, efficacy and predictability. Non-iris recognition group postoperative 1 month and postoperative 3 months 3-order order aberrations root mean square value (RMS) higher than the iris recognition group increased (t = 3.414, -2.870; P = 0.027, 0.045), in particular of coma; the general higher-order aberrations (t = 0.386, 1.132; P = 0.719, 0.321), 4-order aberrations (t = 0.808, 2.720; P = 0.464, 0.063), and 5-order aberrations (t = 0.148, -1.717; P = 0.890, 0.161) show no statistically significant difference. Three months after surgery, two groups have recovered at all spatial frequencies of CSF, iris recognition group at 3.0 c/d (t = 3.209, P = 0.002) and 6.0 c/d (t = 2.997, P = 0.004) spatial frequencies of CSF under mesopic condition was better than non-iris recognition group, glare contrast sensitivity function (GCSF) for 3.0 c/d (t = 3.423, P = 0.001) and 6.0 c/d (t = 6.986, P = 0.000) spatial frequencies under mesopic condition and 1.5 c/d (t = 9.839, P = 0.000) and 3.0 c/d (t = 7.367, P = 0.000) spatial frequencies under photopic condition in iris recognition group were better than non-iris recognition group, there were no significant difference between two groups at the other spatial frequencies. Wavefront-guided LASIK with or without iris recognition both acquired better postoperative visual acuity, but in comparison with without iris recognition, wavefront-guided LASIK with iris recognition is efficient to reduce coma and enhance contrast sensitivity of postoperative.
Human iris three-dimensional imaging at micron resolution by a micro-plenoptic camera
Chen, Hao; Woodward, Maria A.; Burke, David T.; Jeganathan, V. Swetha E.; Demirci, Hakan; Sick, Volker
2017-01-01
A micro-plenoptic system was designed to capture the three-dimensional (3D) topography of the anterior iris surface by simple single-shot imaging. Within a depth-of-field of 2.4 mm, depth resolution of 10 µm can be achieved with accuracy (systematic errors) and precision (random errors) below 20%. We demonstrated the application of our micro-plenoptic imaging system on two healthy irides, an iris with naevi, and an iris with melanoma. The ridges and folds, with height differences of 10~80 µm, on the healthy irides can be effectively captured. The front surface on the iris naevi was flat, and the iris melanoma was 50 ± 10 µm higher than the surrounding iris. The micro-plenoptic imaging system has great potential to be utilized for iris disease diagnosis and continuing, simple monitoring. PMID:29082081
Human iris three-dimensional imaging at micron resolution by a micro-plenoptic camera.
Chen, Hao; Woodward, Maria A; Burke, David T; Jeganathan, V Swetha E; Demirci, Hakan; Sick, Volker
2017-10-01
A micro-plenoptic system was designed to capture the three-dimensional (3D) topography of the anterior iris surface by simple single-shot imaging. Within a depth-of-field of 2.4 mm, depth resolution of 10 µm can be achieved with accuracy (systematic errors) and precision (random errors) below 20%. We demonstrated the application of our micro-plenoptic imaging system on two healthy irides, an iris with naevi, and an iris with melanoma. The ridges and folds, with height differences of 10~80 µm, on the healthy irides can be effectively captured. The front surface on the iris naevi was flat, and the iris melanoma was 50 ± 10 µm higher than the surrounding iris. The micro-plenoptic imaging system has great potential to be utilized for iris disease diagnosis and continuing, simple monitoring.
Crabb, Simon; Danson, Sarah J; Catto, James W F; McDowell, Cathy; Lowder, James N; Caddy, Joshua; Dunkley, Denise; Rajaram, Jessica; Ellis, Deborah; Hill, Stephanie; Hathorn, David; Whitehead, Amy; Kalevras, Mihalis; Huddart, Robert; Griffiths, Gareth
2018-04-03
Urothelial bladder cancer (UBC) accounts for 10,000 new diagnoses and 5000 deaths annually in the UK (Cancer Research UK, http://www.cancerresearchuk.org/health-professional/cancer-statistics/statistics-by-cancer-type/bladder-cancer , Cancer Research UK, Accessed 26 Mar 2018). Cisplatin-based chemotherapy is standard of care therapy for UBC for both palliative first-line treatment of advanced/metastatic disease and radical neoadjuvant treatment of localised muscle invasive bladder cancer. However, cisplatin resistance remains a critical cause of treatment failure and a barrier to therapeutic advance in UBC. Based on supportive pre-clinical data, we hypothesised that DNA methyltransferase inhibition would circumvent cisplatin resistance in UBC and potentially other cancers. The addition of SGI-110 (guadecitabine, a DNA methyltransferase inhibitor) to conventional doublet therapy of gemcitabine and cisplatin (GC) is being tested within the phase Ib/IIa SPIRE clinical trial. SPIRE incorporates an initial, modified rolling six-dose escalation phase Ib design of up to 36 patients with advanced solid tumours followed by a 20-patient open-label randomised controlled dose expansion phase IIa component as neoadjuvant treatment for UBC. Patients are being recruited from UK secondary care sites. The dose escalation phase will determine a recommended phase II dose (RP2D, primary endpoint) of SGI-110, by subcutaneous injection, on days 1-5 for combination with GC at conventional doses (cisplatin 70 mg/m 2 , IV infusion, day 8; gemcitabine 1000 mg/m 2 , IV infusion, days 8 and 15) in every 21-day cycle. In the dose expansion phase, patients will be randomised 1:1 to GC with or without SGI-110 at the proposed RP2D. Secondary endpoints will include toxicity profiles, SGI-110 pharmacokinetics and pharmacodynamic biomarkers, and pathological complete response rates in the dose expansion phase. Analyses will not be powered for formal statistical comparisons and descriptive statistics will be used to describe rates of toxicity, efficacy and translational endpoints by treatment arm. SPIRE will provide evidence for whether SGI-110 in combination with GC chemotherapy is safe and biologically effective prior to future phase II/III trials as a neoadjuvant therapy for UBC and potentially in other cancers treated with GC. EudraCT Number: 2015-004062-29 (entered Dec 7, 2015) ISRCTN registry number: 16332228 (registered on Feb 3, 2016).
System Level RBDO for Military Ground Vehicles using High Performance Computing
2008-01-01
platform. Only the analyses that required more than 24 processors were conducted on the Onyx 350 due to the limited number of processors on the...optimization constraints varied. The queues set the number of processors and number of finite element code licenses available to the analyses. sgi ONYX ...3900: unix 24 MIPS R16000 PROCESSORS 4 IR2 GRAPHICS PIPES 4 IR3 GRAPHICS PIPES 24 GBYTES MEMORY 36 GBYTES LOCAL DISK SPACE sgi ONYX 350: unix 32 MIPS
A Linux Workstation for High Performance Graphics
NASA Technical Reports Server (NTRS)
Geist, Robert; Westall, James
2000-01-01
The primary goal of this effort was to provide a low-cost method of obtaining high-performance 3-D graphics using an industry standard library (OpenGL) on PC class computers. Previously, users interested in doing substantial visualization or graphical manipulation were constrained to using specialized, custom hardware most often found in computers from Silicon Graphics (SGI). We provided an alternative to expensive SGI hardware by taking advantage of third-party, 3-D graphics accelerators that have now become available at very affordable prices. To make use of this hardware our goal was to provide a free, redistributable, and fully-compatible OpenGL work-alike library so that existing bodies of code could simply be recompiled. for PC class machines running a free version of Unix. This should allow substantial cost savings while greatly expanding the population of people with access to a serious graphics development and viewing environment. This should offer a means for NASA to provide a spectrum of graphics performance to its scientists, supplying high-end specialized SGI hardware for high-performance visualization while fulfilling the requirements of medium and lower performance applications with generic, off-the-shelf components and still maintaining compatibility between the two.
Ali, Rabab M; Al-Shorbagy, Muhammad Y; Helmy, Maged W; El-Abhar, Hanan S
2018-07-15
Renal ischemia-reperfusion injury (I/RI) remains a critical clinical situation. Several evidence revealed the potential reno-protective effects of Vitamin D and/or pioglitazone, on renal I/RI. This study addresses the possible involvement of the Wnt4/β-catenin signaling, p-S536NF-κBp65, PPARγ, Ang II/TGF-β, and ACE2 as potential effectors to vitamin D and pioglitazone-mediated renoprotective effects. Two sets of Sprague-Dawley rats (n = 30 rat each), were randomized into sham, I/R, Vit D "alfacalcidol" (5 ng/kg/day), pioglitazone (5 mg/kg/day), and Vit D + pioglitazone groups. In all groups renal biochemical parameters, as well as inflammatory and structural profiles were assessed, besides the expression/contents of Wnt4/β-catenin and pS536-NF-κBp65. All treatments started 7 days before I/RI and animals were killed 24 h after I/RI in the first set, while those in the 2nd set continued their treatments for 14 days. After 24 h, all pre-treatments impeded theI/R effect on neutrophils recruitment, p-S536NF-κBp65, IL-18, NGAL, caspase-3, AngII, ACE-2, PPARγ and TGF-β, besides the expression of Wnt4 and ACE-2 with notable reflection on histological changes. Two weeks after I/RI, except a marked up regulation in Wnt4 expression and a striking elevation in the β-catenin content, the magnitude of the injurious events was relatively less pronounced, an effect that was mostly augmented by the different treatments. The current study pledges a promising and novel reno-protective role of the administration of Vit D and pioglitazone entailing a potential involvement of ICAM-1, MPO, NF-κB, Ang II, ACE2, TGFβ, and a modulation of Wnt4/β-catenin pathway. Copyright © 2018 Elsevier B.V. All rights reserved.
Siebor, Eliane; Neuwirth, Catherine
2013-08-01
Salmonella genomic island 1 (SGI1) is often encountered in antibiotic-resistant Salmonella enterica and exceptionally in Proteus mirabilis. We investigated the prevalence of SGI1-producing clinical isolates of P. mirabilis in our hospital (Dijon, France). A total of 57 strains of P. mirabilis resistant to amoxicillin and/or gentamicin and/or trimethoprim/sulfamethoxazole isolated from August 2011 to February 2012 as well as 9 extended-spectrum β-lactamase (ESBL)-producing P. mirabilis from our collection were tested for the presence of SGI1 by PCR. The complete SGI1 structure from positive isolates [backbone and multidrug resistance (MDR) region] was sequenced. SGI1 was detected in 7 isolates; 5 out of the 57 isolates collected during the study period (9%) and 2 out of the 9 ESBL-producing strains of our collection. The structures of the seven SGI1s were distinct. Three different backbones were identified: one identical to the SGI1 backbone from the epidemic Salmonella Typhimurium DT104, one with variations already described in SGI1-K from Salmonella Kentucky (deletion and insertion of IS1359 in the region spanning from S005 to S009) and one with a variation never detected before (deletion from S005 to S009). Six different MDR regions were identified: four simple variants containing resistance genes already described and two variants harbouring a very complex structure including regions derived from several transposons and IS26 elements with aphA1a never reported to date in SGI1. SGI1 variants are widely distributed among P. mirabilis clinical strains and might spread to other commensal Enterobacteriaceae. This would become a serious public health problem.
Schultz, Eliette; Haenni, Marisa; Mereghetti, Laurent; Siebor, Eliane; Neuwirth, Catherine; Madec, Jean-Yves; Cloeckaert, Axel; Doublet, Benoît
2015-09-01
To characterize MDR genomic islands related to Salmonella genomic island 1 (SGI1) and Proteus genomic island 1 (PGI1) in Proteus mirabilis from human and animal sources in France in light of the previously reported cases. A total of 52 and 46 P. mirabilis clinical strains from human and animal sources, respectively, were studied for the period 2010-13. MDR was assessed by antimicrobial susceptibility testing, PCR detection of SGI1 and PGI1 and PCR mapping of the MDR regions. The diversity of the SGI1/PGI1-positive P. mirabilis strains was assessed by PFGE. Twelve P. mirabilis strains (5 humans and 7 dogs) were found to harbour an MDR island related to SGI1 or PGI1. Among them, several SGI1 variants were identified in diverse P. mirabilis genetic backgrounds. The variant SGI1-V, which harbours the ESBL bla VEB-6 gene, was found in closely genetically related human and dog P. mirabilis strains. The recently described PGI1 element was also identified in human and dog strains. Finally, one strain harboured a novel SGI genomic island closely related to SGI1 and SGI2 without an insertion of the MDR region. This study reports for the first time, to our knowledge, SGI1-positive and PGI1-positive P. mirabilis strains from dogs in France. The genetic diversity of the strains suggests several independent horizontal acquisitions of these MDR elements. The potential transmission of SGI1/PGI1-positive P. mirabilis strains between animals and humans is of public health concern, notably with regard to the spread of ESBL and carbapenemase genes, i.e. bla VEB-6 and bla NDM-1. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Kohnen, T; Kühne, C; Cichocki, M; Strenger, A
2007-01-01
Centration of the ablation zone decisively influences the result of wavefront-guided LASIK. Cyclorotation of the eye occurs as the patient changes from the sitting position during aberrometry to the supine position during laser surgery and may lead to induction of lower and higher order aberrations. Twenty patients (40 eyes) underwent wavefront-guided LASIK (B&L 217z 100 excimer laser) with a static eyetracker driven by iris recognition (mean preoperative SE: -4.72+/-1.45 D; range: -1.63 to -7.00 D). The iris patterns of the patients' eyes were memorized during aberrometry and after flap creation. The mean absolute value of the measured cyclorotation was -1.5+/-4.2 degrees (range: -11.0 to 6.9 degrees ). The mean cyclorotation was 3.5+/-2.7 masculine (range: 0.1 to 11.0 degrees ). In 65% of all eyes cyclorotation was >2 masculine. A static eyetracker driven by iris recognition demonstrated that cyclorotation of up to 11 degrees may occur in myopic and myopic astigmatic eyes when changing from a sitting to a supine position. Use of static eyetrackers with iris recognition may provide a more precise positioning of the ablation profile as they detect and compensate cyclorotation.
An effective approach for iris recognition using phase-based image matching.
Miyazawa, Kazuyuki; Ito, Koichi; Aoki, Takafumi; Kobayashi, Koji; Nakajima, Hiroshi
2008-10-01
This paper presents an efficient algorithm for iris recognition using phase-based image matching--an image matching technique using phase components in 2D Discrete Fourier Transforms (DFTs) of given images. Experimental evaluation using CASIA iris image databases (versions 1.0 and 2.0) and Iris Challenge Evaluation (ICE) 2005 database clearly demonstrates that the use of phase components of iris images makes possible to achieve highly accurate iris recognition with a simple matching algorithm. This paper also discusses major implementation issues of our algorithm. In order to reduce the size of iris data and to prevent the visibility of iris images, we introduce the idea of 2D Fourier Phase Code (FPC) for representing iris information. The 2D FPC is particularly useful for implementing compact iris recognition devices using state-of-the-art Digital Signal Processing (DSP) technology.
Mather, Alison E.; Denwood, Matthew J.; Haydon, Daniel T.; Matthews, Louise; Mellor, Dominic J.; Coia, John E.; Brown, Derek J.; Reid, Stuart W. J.
2011-01-01
Throughout the 1990 s, there was an epidemic of multidrug resistant Salmonella Typhimurium DT104 in both animals and humans in Scotland. The use of antimicrobials in agriculture is often cited as a major source of antimicrobial resistance in pathogenic bacteria of humans, suggesting that DT104 in animals and humans should demonstrate similar prevalences of resistance determinants. Until very recently, only the application of molecular methods would allow such a comparison and our understanding has been hindered by the fact that surveillance data are primarily phenotypic in nature. Here, using large scale surveillance datasets and a novel Bayesian approach, we infer and compare the prevalence of Salmonella Genomic Island 1 (SGI1), SGI1 variants, and resistance determinants independent of SGI1 in animal and human DT104 isolates from such phenotypic data. We demonstrate differences in the prevalences of SGI1, SGI1-B, SGI1-C, absence of SGI1, and tetracycline resistance determinants independent of SGI1 between these human and animal populations, a finding that challenges established tenets that DT104 in domestic animals and humans are from the same well-mixed microbial population. PMID:22125606
NASA Astrophysics Data System (ADS)
Allred, B. W.; Naugle, D.; Donnelly, P.; Tack, J.; Jones, M. O.
2016-12-01
In 2010, the USDA Natural Resources Conservation Service (NRCS) launched the Sage Grouse Initiative (SGI) to voluntarily reduce threats facing sage-grouse and rangelands on private lands. Over the past five years, SGI has matured into a primary catalyst for rangeland and wildlife conservation across the North American west, focusing on the shared vision of wildlife conservation through sustainable working landscapes and providing win-win solutions for producers, sage grouse, and 350 other sagebrush obligate species. SGI and its partners have invested a total of $750 million into rangeland and wildlife conservation. Moving forward, SGI continues to focus on rangeland conservation. Partnering with Google Earth Engine, SGI has developed outcome monitoring and conservation planning tools at continental scales. The SGI science team is currently developing assessment and monitoring algorithms of key conservation indicators. The SGI web application utilizes Google Earth Engine for user defined analysis and planning, putting the appropriate information directly into the hands of managers and conservationists.
An Index to Objectively Score Supraglottic Abnormalities in Refractory Asthma
Good, James T.; Rollins, Donald R.; Curran-Everett, Douglas; Lommatzsch, Steven E.; Carolan, Brendan J.; Stubenrauch, Peter C.
2014-01-01
Background: Patients with refractory asthma frequently have elements of laryngopharyngeal reflux (LPR) with potential aspiration contributing to their poor control. We previously reported on a supraglottic index (SGI) scoring system that helps in the evaluation of LPR with potential aspiration. However, to further the usefulness of this SGI scoring system for bronchoscopists, a teaching system was developed that included both interobserver and intraobserver reproducibility. Methods: Five pulmonologists with expertise in fiber-optic bronchoscopy but novice to the SGI participated. A training system was developed that could be used via Internet interaction to make this learning technique widely available. Results: By the final testing, there was excellent interreader agreement (κ of at least 0.81), thus documenting reproducibility in scoring the SGI. For the measure of intrareader consistency, one reader was arbitrarily selected to rescore the final test 4 weeks later and had a κ value of 0.93, with a 95% CI of 0.79 to 1.00. Conclusions: In this study, we demonstrate that with an organized educational approach, bronchoscopists can develop skills to have highly reproducible assessment and scoring of supraglottic abnormalities. The SGI can be used to determine which patients need additional intervention to determine causes of LPR and gastroesophageal reflux. Identification of this problem in patients with refractory asthma allows for personal, individual directed therapy to improve asthma control. PMID:24202552
Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon
2016-01-01
Purpose To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. Materials and Methods The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00–4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. Results The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Conclusion Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes. PMID:27593877
Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon; Kim, Tae Im
2016-11-01
To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00-4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes.
Mumenthaler, Shannon M; Ng, Patricia Y B; Hodge, Amanda; Bearss, David; Berk, Gregory; Kanekal, Sarath; Redkar, Sanjeev; Taverna, Pietro; Agus, David B; Jain, Anjali
2009-10-01
The serine/threonine family of Pim kinases function as oncogenes and have been implicated in prostate cancer progression, particularly in hormone-refractory prostate disease, as a result of their antiapoptotic function. In this study, we used a pharmacologic inhibitor targeting the Pim family members, SGI-1776, to determine whether modulation of Pim kinase activity could alter prostate cancer cell survival and modulate chemotherapy resistance. Extensive biochemical characterization of SGI-1776 confirmed its specificity for the three isoforms of the Pim family. Treatment of prostate cancer cells with SGI-1776 resulted in a dose-dependent reduction in phosphorylation of known Pim kinase substrates that are involved in cell cycle progression and apoptosis (p21(Cip1/WAF1) and Bad). Consequently, SGI-1776 compromised overall cell viability by inducing G(1) cell cycle arrest and triggering apoptosis. Overexpression of recombinant Pim-1 markedly increased sensitivity of SGI-1776-mediated prostate cancer cell apoptosis and p21(Cip1/WAF1) phosphorylation inhibition, reinforcing the specificity of SGI-1776. An additional cytotoxic effect was observed when SGI-1776 was combined with taxane-based chemotherapy agents. SGI-1776 was able to reduce cell viability in a multidrug resistance 1 protein-based taxane-refractory prostate cancer cell line. In addition, SGI-1776 treatment was able to resensitize chemoresistant cells to taxane-based therapies by inhibiting multidrug resistance 1 activity and inducing apoptosis. These findings support the idea that inhibiting Pim kinases, in combination with a chemotherapeutic agent, could play an important role in prostate cancer treatment by targeting the clinical problem of chemoresistance.
Malyugin, Boris E; Shpak, Alexander A; Pokrovskiy, Dmitry F
2015-08-01
To use anterior segment optical coherence tomography (AS-OCT) to evaluate the clinical effectiveness of Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) sizing based on measurement of the distance from the iris pigment end to the iris pigment end. S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, Russia. Evaluation of diagnostic test or technology. Stage 1 was a prospective study. The sulcus-to-sulcus (STS) distance was measured using ultrasound biomicroscopy (UBM) (Vumax 2), and the distance from iris pigment end to iris pigment end was assessed using a proposed AS-OCT algorithm. Part 2 used retrospective data from patients after implantation of a PC pIOL with the size selected according to AS-OCT (Visante) measurements of the distance from iris pigment end to iris pigment end. The PC pIOL vault was measured by AS-OCT, and adverse events were assessed. Stage 1 comprised 32 eyes of 32 myopic patients (mean age 28.4 years ± 6.3 [SD]; mean spherical equivalent [SE] -13.11 ± 4.28 diopters [D]). Stage 2 comprised 29 eyes of 16 patients (mean age 27.7 ± 4.7 years; mean SE -16.55 ± 3.65 D). The mean STS distance (12.35 ± 0.47 mm) was similar to the mean distance from iris pigment end to iris pigment end distance (examiner 1: 12.36 ± 0.51 mm; examiner 2: 12.37 ± 0.53 mm). The PC pIOL sized using the new AS-OCT algorithm had a mean vault of 0.53 ± 0.18 mm and did not produce adverse events during the 12-month follow-up. In 16 of 29 eyes, the PC pIOL vault was within an optimum interval (0.35 to 0.70 mm). The new measurement algorithm can be effectively used for PC pIOL sizing. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
2010-03-16
Exceeded at ERP Soil and Groundwater Sites 86 A-2a. Identification of IRIS Chemicals of Interest on the ATSDR CERCLA Priority List of Hazardous...the Number (Bold Font) of Air Force ERP Samples in Which They Were Detected 317 A-4d. Air Force ERP Soil Samples: IRIS Chemicals of Interest...Ranked by the Number (Bold Font) of Air Force ERP Soil Samples in Which They Were Detected 333 A-4e. Air Force ERP Groundwater Samples: IRIS Chemicals of
Peterson, Jeffrey R.; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Rigi, Mohammed; Feldman, Robert M.; Bell, Nicholas P.
2016-01-01
Purpose Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Methods Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18–35, 36–45, 46–55, 56–65, and 66–79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Results Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. Conclusion This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states. PMID:26815917
Peterson, Jeffrey R; Blieden, Lauren S; Chuang, Alice Z; Baker, Laura A; Rigi, Mohammed; Feldman, Robert M; Bell, Nicholas P
2016-01-01
Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.
Parallel Rendering of Large Time-Varying Volume Data
NASA Technical Reports Server (NTRS)
Garbutt, Alexander E.
2005-01-01
Interactive visualization of large time-varying 3D volume datasets has been and still is a great challenge to the modem computational world. It stretches the limits of the memory capacity, the disk space, the network bandwidth and the CPU speed of a conventional computer. In this SURF project, we propose to develop a parallel volume rendering program on SGI's Prism, a cluster computer equipped with state-of-the-art graphic hardware. The proposed program combines both parallel computing and hardware rendering in order to achieve an interactive rendering rate. We use 3D texture mapping and a hardware shader to implement 3D volume rendering on each workstation. We use SGI's VisServer to enable remote rendering using Prism's graphic hardware. And last, we will integrate this new program with ParVox, a parallel distributed visualization system developed at JPL. At the end of the project, we Will demonstrate remote interactive visualization using this new hardware volume renderer on JPL's Prism System using a time-varying dataset from selected JPL applications.
Research in Parallel Algorithms and Software for Computational Aerosciences
NASA Technical Reports Server (NTRS)
Domel, Neal D.
1996-01-01
Phase I is complete for the development of a Computational Fluid Dynamics parallel code with automatic grid generation and adaptation for the Euler analysis of flow over complex geometries. SPLITFLOW, an unstructured Cartesian grid code developed at Lockheed Martin Tactical Aircraft Systems, has been modified for a distributed memory/massively parallel computing environment. The parallel code is operational on an SGI network, Cray J90 and C90 vector machines, SGI Power Challenge, and Cray T3D and IBM SP2 massively parallel machines. Parallel Virtual Machine (PVM) is the message passing protocol for portability to various architectures. A domain decomposition technique was developed which enforces dynamic load balancing to improve solution speed and memory requirements. A host/node algorithm distributes the tasks. The solver parallelizes very well, and scales with the number of processors. Partially parallelized and non-parallelized tasks consume most of the wall clock time in a very fine grain environment. Timing comparisons on a Cray C90 demonstrate that Parallel SPLITFLOW runs 2.4 times faster on 8 processors than its non-parallel counterpart autotasked over 8 processors.
Research in Parallel Algorithms and Software for Computational Aerosciences
NASA Technical Reports Server (NTRS)
Domel, Neal D.
1996-01-01
Phase 1 is complete for the development of a computational fluid dynamics CFD) parallel code with automatic grid generation and adaptation for the Euler analysis of flow over complex geometries. SPLITFLOW, an unstructured Cartesian grid code developed at Lockheed Martin Tactical Aircraft Systems, has been modified for a distributed memory/massively parallel computing environment. The parallel code is operational on an SGI network, Cray J90 and C90 vector machines, SGI Power Challenge, and Cray T3D and IBM SP2 massively parallel machines. Parallel Virtual Machine (PVM) is the message passing protocol for portability to various architectures. A domain decomposition technique was developed which enforces dynamic load balancing to improve solution speed and memory requirements. A host/node algorithm distributes the tasks. The solver parallelizes very well, and scales with the number of processors. Partially parallelized and non-parallelized tasks consume most of the wall clock time in a very fine grain environment. Timing comparisons on a Cray C90 demonstrate that Parallel SPLITFLOW runs 2.4 times faster on 8 processors than its non-parallel counterpart autotasked over 8 processors.
Soliman, Ahmed M; Ahmed, Ashraf M; Shimamoto, Toshi; El-Domany, Ramadan A; Nariya, Hirofumi; Shimamoto, Tadashi
2017-07-01
Two Proteus mirabilis strains, designated PmTAN59 and PmKAF126, were isolated from two different Egyptian cities in 2014 and 2015, respectively. PmTAN59 was isolated from a sputum swab from a pneumonia patient in Tanta University Teaching Hospital. PmKAF126 was isolated from a patient with a diabetic foot infection in a hospital in the city of Kafr El-Sheikh. The two isolates were identified with bacterial small ribosomal RNA (16S rRNA) gene amplification and sequencing and tested for antimicrobial sensitivity with a Kirby-Bauer disk diffusion assay. The two strains were resistant to amoxicillin/clavulante, ampicillin, cefotaxime, cefoxitin, ceftriaxone, chloramphenicol, ciprofloxacin, colistin, gentamicin, kanamycin, nalidixic acid, spectinomycin, streptomycin, sulfamethoxazole/trimethoprime, and tetracycline, but sensitive to aztreonam, imipenem, and meropenem. Molecular characterization was used to map the entire backbone, including the multiple antibiotic resistance (MDR) region, of Salmonella genomic island 1 (SGI1). Both isolates carried a structure similar to SGI1, with two different MDR regions corresponding to SGI1-PmABB in PmTAN59 and SGI1-W in PmKAF126. SGI1-PmABB carried an integron of ~1.5kb with a two-gene cassette, aacCA5-aadA7, which confers resistance to gentamicin, streptomycin, and spectinomycin, whereas SGI1-W carried an integron of ~1.9kb containing aadA2-lnuF, which confers resistance to spectinomycin, streptomycin, and lincosamides. PmKAF126 carried the entire SGI1 sequence, however PmTAN59 carried a SGI1 structure with a deletion in the region from ORF S005 to ORF S009 and accompanied by insertion of IS1359 (1258bp). Furthermore, PmTAN59 carried class 2 integron of ~2.2kb containing dfrA1-sat2-aadA1. An ERIC-PCR analysis detected no clonal relationship between the two strains. Molecular screening for other antimicrobial resistance genes and a plasmid analysis indicated that PmTAN59 carried an IncFIB plasmid type. This strain also carried bla TEM-1 and the plasmid-mediated quinolone-resistance gene qnrA1. However, PmKAF126 carried no plasmids and no resistance gene other than that contained in the MDR region of SGI1 and floR gene conferring resistance to florfenicol. To the best of our knowledge, this is the first report of an SGI1-positive P. mirabilis strain in Egypt or on the entire African continent. Copyright © 2017 Elsevier B.V. All rights reserved.
Pim kinase inhibitor, SGI-1776, induces apoptosis in chronic lymphocytic leukemia cells.
Chen, Lisa S; Redkar, Sanjeev; Bearss, David; Wierda, William G; Gandhi, Varsha
2009-11-05
Pim kinases are involved in B-cell development and are overexpressed in B-cell chronic lymphocytic leukemia (CLL). We hypothesized that Pim kinase inhibition would affect B-cell survival. Identified from a screen of imidazo[1,2-b]pyridazine compounds, SGI-1776 inhibits Pim-1, Pim-2, and Pim-3. Treatment of CLL cells with SGI-1776 results in a concentration-dependent induction of apoptosis. To elucidate its mechanism of action, we evaluated the effect of SGI-1776 on Pim kinase function. Unlike in replicating cells, phosphorylation of traditional Pim-1 kinase targets, phospho-Bad (Ser112) and histone H3 (Ser10), and cell-cycle proteins were unaffected by SGI-1776, suggesting an alternative mechanism in CLL. Protein levels of total c-Myc as well as phospho-c-Myc(Ser62), a Pim-1 target site, were decreased after SGI-1776 treatment. Levels of antiapoptotic proteins Bcl-2, Bcl-X(L), XIAP, and proapoptotic Bak and Bax were unchanged; however, a significant reduction in Mcl-1 was observed that was not caused by caspase-mediated cleavage of Mcl-1 protein. The mechanism of decline in Mcl-1 was at the RNA level and was correlated with inhibition of global RNA synthesis. Consistent with a decline in new RNA synthesis, MCL-1 transcript levels were decreased after treatment with SGI-1776. These data suggest that SGI-1776 induces apoptosis in CLL and that the mechanism involves Mcl-1 reduction.
Pim kinase inhibitor, SGI-1776, induces apoptosis in chronic lymphocytic leukemia cells
Chen, Lisa S.; Redkar, Sanjeev; Bearss, David; Wierda, William G.
2009-01-01
Pim kinases are involved in B-cell development and are overexpressed in B-cell chronic lymphocytic leukemia (CLL). We hypothesized that Pim kinase inhibition would affect B-cell survival. Identified from a screen of imidazo[1,2-b]pyridazine compounds, SGI-1776 inhibits Pim-1, Pim-2, and Pim-3. Treatment of CLL cells with SGI-1776 results in a concentration-dependent induction of apoptosis. To elucidate its mechanism of action, we evaluated the effect of SGI-1776 on Pim kinase function. Unlike in replicating cells, phosphorylation of traditional Pim-1 kinase targets, phospho-Bad (Ser112) and histone H3 (Ser10), and cell-cycle proteins were unaffected by SGI-1776, suggesting an alternative mechanism in CLL. Protein levels of total c-Myc as well as phospho-c-Myc(Ser62), a Pim-1 target site, were decreased after SGI-1776 treatment. Levels of antiapoptotic proteins Bcl-2, Bcl-XL, XIAP, and proapoptotic Bak and Bax were unchanged; however, a significant reduction in Mcl-1 was observed that was not caused by caspase-mediated cleavage of Mcl-1 protein. The mechanism of decline in Mcl-1 was at the RNA level and was correlated with inhibition of global RNA synthesis. Consistent with a decline in new RNA synthesis, MCL-1 transcript levels were decreased after treatment with SGI-1776. These data suggest that SGI-1776 induces apoptosis in CLL and that the mechanism involves Mcl-1 reduction. PMID:19734450
NASA Technical Reports Server (NTRS)
Fales, Janine L.
1991-01-01
The capabilities of the postprocessing program CANDI (Color Animation of Nastran DIsplacements) were expanded to accept results from axisymmetric analysis. An auxiliary program, ANIMATE, was developed to allow color display of CANDI output on the IRIS 4D-series workstations. The user can interactively manipulate the graphics display by three-dimensional rotations, translations, and scaling through the use of the keyboard and/or dials box. The user can also specify what portion of the model is displayed. These developments are limited to the display of complex displacements calculated with the NASHUA/NASTRAN procedure for structural acoustics analysis.
The Epidemiology of IRIS in Southern India: An Observational Cohort Study
Thambuchetty, Nisha; Mehta, Kayur; Arumugam, Karthika; Shekarappa, Umadevi G.; Idiculla, Jyothi; Shet, Anita
2018-01-01
Immune reconstitution inflammatory syndrome (IRIS) is an uncommon but dynamic phenomenon seen among patients initiating antiretroviral therapy (ART). We aimed to describe incidence, risk factors, clinical spectrum, and outcomes among ART-naive patients experiencing IRIS in southern India. Among 599 eligible patients monitored prospectively between 2012 and 2014, there were 59.3% males, with mean age 36.6 ± 7.8 years. Immune reconstitution inflammatory syndrome incidence rate was 51.3 per 100 person-years (95% confidence interval: 44.5-59.2). One-third (31.4%) experienced at least 1 IRIS event, at a median of 27 days since ART initiation. Mucocutaneous infections and candidiasis were common IRIS events, followed by tuberculosis. Significant risk factors included age >40 years, body mass index <18.5 kg/m2, CD4 count <100 cells/mm3, viral load >10 000 copies/mL, hemoglobin <1 g/dL, and erythrocyte sedimentation rate >50 mm/h. Immune reconstitution inflammatory syndrome–related morality was 1.3% (8 of 599); 3 patients died of complicated diarrhea. These findings highlight the current spectrum of IRIS in South India and underscore the importance of heightened vigilance for anemia and treatment of diarrhea and candidiasis during ART initiation. PMID:28399724
Kruh, Jonathan N; Garrett, Kenneth A; Huntington, Brian; Robinson, Steve; Melki, Samir A
2017-01-01
To identify risks factors for retreatment post-laser in situ keratomeliusis (LASIK). A retrospective chart review from December 2008 to September 2012 identified 1,402 patients (2,581 eyes) that underwent LASIK treatment for myopia with the Intralase™ FS, STAR S4 IR™ Excimer Laser, and WaveScan WaveFront™ technology. In this group, 83 patients were retreated. All charts were reviewed for preoperative age, gender, initial manifest refraction spherical equivalent (MRSE), total astigmatism, and iris registration. Increased incidence rates of retreatment post-LASIK were preoperative age >40 years (p < 0.001), initial MRSE > -3.0 D (p = 0.02), and astigmatism >1D (p = 0.001). Iris registration capture did not significantly reduce the retreatment rate (p = 0.12). Risk factors for retreatment included preoperative age >40 years, initial MRSE > -3.0 D, and astigmatism >1D. There was no difference in retreatment rate for patients based on gender or iris registration capture.
Scaling NASA Applications to 1024 CPUs on Origin 3K
NASA Technical Reports Server (NTRS)
Taft, Jim
2002-01-01
The long and highly successful joint SGI-NASA research effort in ever larger SSI systems was to a large degree the result of the successful development of the MLP scalable parallel programming paradigm developed at ARC: 1) MLP scaling in real production codes justified ever larger systems at NAS; 2) MLP scaling on 256p Origin 2000 gave SGl impetus to productize 256p; 3) MLP scaling on 512 gave SGI courage to build 1024p O3K; and 4) History of MLP success resulted in IBM Star Cluster based MLP effort.
Despite the increasing use of urban stormwater green infrastructure (SGI), including detention ponds and rain gardens, few studies have quantified the cumulative effects of multiple SGI projects on hydrology and water quality at the watershed scale. To assess the effects of SGI, ...
The D/H ratio in Saturn's atmosphere from Voyager IRIS spectra
NASA Technical Reports Server (NTRS)
Courtin, R.; Gautier, D.; Marten, A.; Bezard, B.; Hanel, R.
1985-01-01
A selection of 1656 spectra recorded between 180 and 2300 mm in the 20 to 40 N latitude range by the Voyager interferometer IRIS were analyzed. The CH3D/H2 and CH4/H2 ratios are determined from a best fit of the radiances measured in the nu6 and nu4 fundamental bands, respectively centered at 1161 and 1304 mm. Results are CH3D/H2 = 3.9 + or - 2.5 times 10 to the minus 7th power and CH4/H2 = 4.5 + 2.4, -1.9 x 0.001. The uncertainty includes random errors due to instrumental noise and possible systematic errors in the assumed temperature profile and spectroscopic parameters. The D/H isotopic ratio is determined from abundance ratios from the expression D/H = 1/4f (CH3D/H2)/(CH4/H2) where f accounts for equilibrium deuterium fractionation between the molecular hydrogen and methane phases. Beer and Taylor (1973, 1978) estimated f = 1.37 + or - 0.07 for Jupiter assuming a wide range of convective velocities and neglecting catalytic effects from dust particles. The same value was adopted for Saturn and yields D/H = 1.6 +1.3, -1.2 times 10 to the minus 5th power.
NASA Astrophysics Data System (ADS)
Meertens, C.; Wier, S.; Ahern, T.; Casey, R.; Weertman, B.; Laughbon, C.
2008-12-01
UNAVCO and the IRIS DMC are data service partners for seismic visualization, particularly for hypocentral data and tomography. UNAVCO provides the GEON Integrated Data Viewer (IDV), an extension of the Unidata IDV, a free, interactive, research-level, software display and analysis tool for data in 3D (latitude, longitude, depth) and 4D (with time), located on or inside the Earth. The GEON IDV is designed to meet the challenge of investigating complex, multi-variate, time-varying, three- dimensional geoscience data in the context of new remote and shared data sources. The GEON IDV supports data access from data sources using HTTP and FTP servers, OPeNDAP servers, THREDDS catalogs, RSS feeds, and WMS (web map) servers. The IRIS DMC (Data Management System) has developed web services providing data for earthquake hypocentral data and seismic tomography model grids. These services can be called by the GEON IDV to access data at IRIS without copying files. The IRIS Earthquake Browser (IEB) is a web-based query tool for hypocentral data. The IEB combines the DMC's large database of more than 1,900,000 earthquakes with the Google Maps web interface. With the IEB you can quickly find earthquakes in any region of the globe and then import this information into the GEON Integrated Data Viewer where the hypocenters may be visualized. You can select earthquakes by location region, time, depth, and magnitude. The IEB gives the IDV a URL to the selected data. The IDV then shows the data as maps or 3D displays, with interactive control of vertical scale, area, map projection, with symbol size and color control by magnitude or depth. The IDV can show progressive time animation of, for example, aftershocks filling a source region. The IRIS Tomoserver converts seismic tomography model output grids to NetCDF for use in the IDV. The Tomoserver accepts a tomographic model file as input from a user and provides an equivalent NetCDF file as output. The service supports NA04, S3D, A1D and CUB input file formats, contributed by their respective creators. The NetCDF file is saved to a location that can be referenced with a URL on an IRIS server. The URL for the NetCDF file is provided to the user. The user can download the data from IRIS, or copy the URL into IDV directly for interpretation, and the IDV will access the data at IRIS. The Tomoserver conversion software was developed by Instrumental Software Technologies, Inc. Use cases with the GEON IDV and IRIS DMC data services will be shown.
Small incision guarded hydroaspiration of iris lesions.
Singh, Arun D
2017-11-01
To describe the technique and results of a minimally invasive surgical technique for resection of small iris lesions. Consecutive case series of 22 patients with localised, small iris lesions that were resected using the described surgical technique that composed of multiple, small corneal incisions created to allow for internal iris resection with 23-gauge horizontal vitrectomy scissors, followed by guarded tumour aspiration through a clear plastic tubing (diameter 3.5 mm) primed with viscoelastic agent. The mean largest basal diameter was 3.0 mm (range 1.5-5.0 mm; median 3.0 mm) and mean thickness was 1.3 mm (range 0.5-2.5 mm; median 1.0 mm). Use of multiple (2-4) small corneal incisions (range 2.0-3.0 mm; mean 2.8 mm) allowed reduced postoperative morbidity (significant hyphema (0%), hypotony (0%), wound leak (0%), >2 line change in best corrected visual acuity at postoperative 1 week (4.5%) and mean corneal astigmatism of 1.0 D (range 0.14-2.99 D; median 0.8 D) at postoperative 4-12 weeks. The tumour could be resected with clear surgical margins in all neoplastic cases (benign (2), borderline (1) and malignant (16)). Local recurrence or metastases were not observed in any melanoma case over a mean follow-up of 33.0 months (range 1.0-90.0 months; median 33.5 months). Small incision guarded hydroaspiration is a minimally invasive surgical technique for resection of select small iris lesions. Use of multiple small corneal incisions avoids morbidity associated with a single large corneoscleral incision, and use of guarded aspiration may eliminate the risk of wound contamination by the malignant tumour. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
PLOT3D/AMES, GENERIC UNIX VERSION USING DISSPLA (WITH TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. The UNIX/DISSPLA implementation of PLOT3D supports 2-D polygons as well as 2-D and 3-D lines, but does not support graphics features requiring 3-D polygons (shading and hidden line removal, for example). Views can be manipulated using keyboard commands. This version of PLOT3D is potentially able to produce files for a variety of output devices; however, site-specific capabilities will vary depending on the device drivers supplied with the user's DISSPLA library. The version 3.6b+ UNIX/DISSPLA implementations of PLOT3D (ARC-12788) and PLOT3D/TURB3D (ARC-12778) were developed for use on computers running UNIX SYSTEM 5 with BSD 4.3 extensions. The standard distribution media for each ofthese programs is a 9track, 6250 bpi magnetic tape in TAR format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: (1) generic UNIX Supercomputer and IRIS, suitable for CRAY 2/UNICOS, CONVEX, Alliant with remote IRIS 2xxx/3xxx or IRIS 4D (ARC-12779, ARC-12784); (2) Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D (ARC-12783, ARC-12782); (3) VAX computers running VMS Version 5.0 and DISSPLA Version 11.0 (ARC-12777, ARC-12781); and (4) Apollo computers running UNIX and GMR3D Version 2.0 (ARC-12789, ARC-12785 which have no capabilities to put text on plots). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo and GMR3D are trademarks of Hewlett-Packard, Incorporated. System 5 is a trademark of Bell Labs, Incorporated. BSD4.3 is a trademark of the University of California at Berkeley. UNIX is a registered trademark of AT&T.
PLOT3D/AMES, GENERIC UNIX VERSION USING DISSPLA (WITHOUT TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. The UNIX/DISSPLA implementation of PLOT3D supports 2-D polygons as well as 2-D and 3-D lines, but does not support graphics features requiring 3-D polygons (shading and hidden line removal, for example). Views can be manipulated using keyboard commands. This version of PLOT3D is potentially able to produce files for a variety of output devices; however, site-specific capabilities will vary depending on the device drivers supplied with the user's DISSPLA library. The version 3.6b+ UNIX/DISSPLA implementations of PLOT3D (ARC-12788) and PLOT3D/TURB3D (ARC-12778) were developed for use on computers running UNIX SYSTEM 5 with BSD 4.3 extensions. The standard distribution media for each ofthese programs is a 9track, 6250 bpi magnetic tape in TAR format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: (1) generic UNIX Supercomputer and IRIS, suitable for CRAY 2/UNICOS, CONVEX, Alliant with remote IRIS 2xxx/3xxx or IRIS 4D (ARC-12779, ARC-12784); (2) Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D (ARC-12783, ARC-12782); (3) VAX computers running VMS Version 5.0 and DISSPLA Version 11.0 (ARC-12777, ARC-12781); and (4) Apollo computers running UNIX and GMR3D Version 2.0 (ARC-12789, ARC-12785 which have no capabilities to put text on plots). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo and GMR3D are trademarks of Hewlett-Packard, Incorporated. System 5 is a trademark of Bell Labs, Incorporated. BSD4.3 is a trademark of the University of California at Berkeley. UNIX is a registered trademark of AT&T.
First Demonstration of Ocular Refractive Change Using Blue-IRIS in Live Cats
Savage, Daniel E.; Brooks, Daniel R.; DeMagistris, Margaret; Xu, Lisen; MacRae, Scott; Ellis, Jonathan D.; Knox, Wayne H.; Huxlin, Krystel R.
2014-01-01
Purpose. To determine the efficacy of intratissue refractive index shaping (IRIS) using 400-nm femtosecond laser pulses (blue light) for writing refractive structures directly into live cat corneas in vivo, and to assess the longevity of these structures in the eyes of living cats. Methods. Four eyes from two adult cats underwent Blue-IRIS. Light at 400 nm with 100-femtosecond (fs) pulses were tightly focused into the corneal stroma of each eye at an 80-MHz repetition rate. These pulses locally increased the refractive index of the corneal stroma via an endogenous, two-photon absorption process and were used to inscribe three-layered, gradient index patterns into the cat corneas. The optical effects of the patterns were then tracked using optical coherence tomography (OCT) and Shack-Hartmann wavefront sensing. Results. Blue-IRIS patterns locally changed ocular cylinder by −1.4 ± 0.3 diopters (D), defocus by −2.0 ± 0.5 D, and higher-order root mean square (HORMS) by 0.31 ± 0.04 μm at 1 month post-IRIS, without significant changes in corneal thickness or curvature. Refractive changes were maintained for the duration they were tracked, 12 months post-IRIS in one eye, and just more than 3 months in the remaining three eyes. Conclusions. Blue-IRIS can be used to inscribe refractive structures into live cat cornea in vivo that are stable for at least 12 months, and are not associated with significant alterations in corneal thicknesses or radii of curvature. This result is a critical step toward establishing Blue-IRIS as a promising technique for noninvasive vision correction. PMID:24985471
First demonstration of ocular refractive change using blue-IRIS in live cats.
Savage, Daniel E; Brooks, Daniel R; DeMagistris, Margaret; Xu, Lisen; MacRae, Scott; Ellis, Jonathan D; Knox, Wayne H; Huxlin, Krystel R
2014-07-01
To determine the efficacy of intratissue refractive index shaping (IRIS) using 400-nm femtosecond laser pulses (blue light) for writing refractive structures directly into live cat corneas in vivo, and to assess the longevity of these structures in the eyes of living cats. Four eyes from two adult cats underwent Blue-IRIS. Light at 400 nm with 100-femtosecond (fs) pulses were tightly focused into the corneal stroma of each eye at an 80-MHz repetition rate. These pulses locally increased the refractive index of the corneal stroma via an endogenous, two-photon absorption process and were used to inscribe three-layered, gradient index patterns into the cat corneas. The optical effects of the patterns were then tracked using optical coherence tomography (OCT) and Shack-Hartmann wavefront sensing. Blue-IRIS patterns locally changed ocular cylinder by -1.4 ± 0.3 diopters (D), defocus by -2.0 ± 0.5 D, and higher-order root mean square (HORMS) by 0.31 ± 0.04 μm at 1 month post-IRIS, without significant changes in corneal thickness or curvature. Refractive changes were maintained for the duration they were tracked, 12 months post-IRIS in one eye, and just more than 3 months in the remaining three eyes. Blue-IRIS can be used to inscribe refractive structures into live cat cornea in vivo that are stable for at least 12 months, and are not associated with significant alterations in corneal thicknesses or radii of curvature. This result is a critical step toward establishing Blue-IRIS as a promising technique for noninvasive vision correction. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
NASA Astrophysics Data System (ADS)
Ceschini, L.; Morri, Alessandro; Morri, Andrea
2017-05-01
The aim of this research was to investigate the effects of casting size (10-210 mm) on the microstructure and mechanical properties of spheroidal (SGI) and compacted (CGI) graphite cast irons. A comparison of the experimental mechanical data with those specified by ISO standards is presented and discussed. The study highlighted that the microstructure and mechanical properties of SGI (also known as ductile or nodular cast iron) are more sensitive to casting size than CGI (also known as vermicular graphite cast irons). In particular, in both types of cast iron, hardness, yield strength and ultimate tensile strength decreased, with increasing casting size, by 27% in SGI and 17% in CGI. Elongation to failure showed, instead, an opposite trend, decreasing from 5 to 3% in CGI, while increasing from 5 to 11% in SGI. These results were related to different microstructures, the ferritic fraction being more sensitive to the casting size in SGI than CGI. Degeneration of spheroidal graphite was observed at casting size above 120 mm. The microstructural similarities between degenerated SGI and CGI suggested the proposal of a unified empirical constitutional law relating the most important microstructural parameters to the ultimate tensile strength. An outstanding result was also the finding that standard specifications underestimated the mechanical properties of both cast irons (in particular SGI) and, moreover, did not take into account their variation with casting size, at thicknesses over 60 mm.
An Improved Iris Recognition Algorithm Based on Hybrid Feature and ELM
NASA Astrophysics Data System (ADS)
Wang, Juan
2018-03-01
The iris image is easily polluted by noise and uneven light. This paper proposed an improved extreme learning machine (ELM) based iris recognition algorithm with hybrid feature. 2D-Gabor filters and GLCM is employed to generate a multi-granularity hybrid feature vector. 2D-Gabor filter and GLCM feature work for capturing low-intermediate frequency and high frequency texture information, respectively. Finally, we utilize extreme learning machine for iris recognition. Experimental results reveal our proposed ELM based multi-granularity iris recognition algorithm (ELM-MGIR) has higher accuracy of 99.86%, and lower EER of 0.12% under the premise of real-time performance. The proposed ELM-MGIR algorithm outperforms other mainstream iris recognition algorithms.
Performance Evaluation of Supercomputers using HPCC and IMB Benchmarks
NASA Technical Reports Server (NTRS)
Saini, Subhash; Ciotti, Robert; Gunney, Brian T. N.; Spelce, Thomas E.; Koniges, Alice; Dossa, Don; Adamidis, Panagiotis; Rabenseifner, Rolf; Tiyyagura, Sunil R.; Mueller, Matthias;
2006-01-01
The HPC Challenge (HPCC) benchmark suite and the Intel MPI Benchmark (IMB) are used to compare and evaluate the combined performance of processor, memory subsystem and interconnect fabric of five leading supercomputers - SGI Altix BX2, Cray XI, Cray Opteron Cluster, Dell Xeon cluster, and NEC SX-8. These five systems use five different networks (SGI NUMALINK4, Cray network, Myrinet, InfiniBand, and NEC IXS). The complete set of HPCC benchmarks are run on each of these systems. Additionally, we present Intel MPI Benchmarks (IMB) results to study the performance of 11 MPI communication functions on these systems.
Prakash, Gaurav; Agarwal, Amar; Kumar, Dhivya Ashok; Jacob, Soosan; Agarwal, Athiya; Maity, Amrita
2011-03-01
To evaluate the visual and refractive outcomes and expected benefits of Tissue Saving Treatment algorithm-guided surface ablation with iris recognition and dynamic rotational eye tracking. This prospective, interventional case series comprised 122 eyes (70 patients). Pre- and postoperative assessment included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, and higher order aberrations. All patients underwent Tissue Saving Treatment algorithm-guided surface ablation with iris recognition and dynamic rotational eye tracking using the Technolas 217z 100-Hz excimer platform (Technolas Perfect Vision GmbH). Follow-up was performed up to 6 months postoperatively. Theoretical benefit analysis was performed to evaluate the algorithm's outcomes compared to others. Preoperative spherocylindrical power was sphere -3.62 ± 1.60 diopters (D) (range: 0 to -6.75 D), cylinder -1.15 ± 1.00 D (range: 0 to -3.50 D), and spherical equivalent -4.19 ± 1.60 D (range: -7.75 to -2.00 D). At 6 months, 91% (111/122) of eyes were within ± 0.50 D of attempted correction. Postoperative UDVA was comparable to preoperative CDVA at 1 month (P=.47) and progressively improved at 6 months (P=.004). Two eyes lost one line of CDVA at 6 months. Theoretical benefit analysis revealed that of 101 eyes with astigmatism, 29 would have had cyclotorsion-induced astigmatism of ≥ 10% if iris recognition and dynamic rotational eye tracking were not used. Furthermore, the mean percentage decrease in maximum depth of ablation by using the Tissue Saving Treatment was 11.8 ± 2.9% over Aspheric, 17.8 ± 6.2% over Personalized, and 18.2 ± 2.8% over Planoscan algorithms. Tissue saving surface ablation with iris recognition and dynamic rotational eye tracking was safe and effective in this series of eyes. Copyright 2011, SLACK Incorporated.
H-mode fueling optimization with the supersonic deuterium jet in NSTX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soukhanovskii, V A; Bell, M G; Bell, R E
2008-06-18
High-performance, long-pulse 0.7-1.2 MA 6-7 MW NBI-heated small-ELM H-mode plasma discharges are developed in the National Spherical Torus Experiment (NSTX) as prototypes for confinement and current drive extrapolations to future spherical tori. It is envisioned that innovative lithium coating techniques for H-mode density pumping and a supersonic deuterium jet for plasma refueling will be used to achieve the low pedestal collisionality and low n{sub e}/n{sub G} fractions (0.3-0.6), both of which being essential conditions for maximizing the non-inductive (bootstrap and beam driven) current fractions. The low field side supersonic gas injector (SGI) on NSTX consists of a small converging-diverging graphitemore » Laval nozzle and a piezoelectric gas valve. The nozzle is capable of producing a deuterium jet with Mach number M {le} 4, estimated gas density at the nozzle exit n {le} 5 x 10{sup 23} m{sup -3}, estimated temperature T {ge} 70 K, and flow velocity v = 2:4 km/s. The nozzle Reynolds number Reis {approx_equal} 6000. The nozzle and the valve are enclosed in a protective carbon fiber composite shroud and mounted on a movable probe at a midplane port location. Despite the beneficial L-mode fueling experience with supersonic jets in limiter tokamaks, there is a limited experience with fueling of high-performance H-mode divertor discharges and the associated density, MHD stability, and MARFE limits. In initial supersonic deuterium jet fueling experiments in NSTX, a reliable H-mode access, a low NBI power threshold, P{sub LH} {le} 2 MW, and a high fueling efficiency (0.1-0.4) have been demonstrated. Progress has also been made toward a better control of the injected fueling gas by decreasing the uncontrolled high field side (HFS) injector fueling rate by up to 95 % and complementing it with the supersonic jet fueling. These results motivated recent upgrades to the SGI gas delivery and control systems. The new SGI-Upgrade (SGI-U) capabilities include multi-pulse ms-scale controls and a reservoir gas pressure up to P{sub 0} = 5000 Torr. In this paper we summarize recent progress toward optimization of H-mode fueling in NSTX using the SGI-U.« less
NASA Technical Reports Server (NTRS)
Drossart, P.; Encrenaz, T.; Combes, M.; Kunde, V.; Hanel, R.
1982-01-01
No evidence is found for large scale phosphine abundance variations over Jovian latitudes between -30 and +30 deg, in PH3, CH3D, and GeH4 abundances derived from the 2100-2250/cm region of the Voyager 1 IRIS spectra. The PH3/H2 value of (4.5 + or - 1.5) X 10 to the -7th derived from atmospheric regions corresponding to 170-200 K is 0.75 + or - 0.25 times the solar value, and suggests that the PH3/H2 ratio on Jupiter decreases with atmospheric pressure upon comparison with other PH3 determinations at 10 microns. In the 200-250 K region, CH3D/H2 and GeH4/H2 ratios of 2.0 X 10 to the -7th and 1.0 X 10 to the -9th, respectively, are derived within a factor of 2.0. Assuming a C/H value of 0.001, as derived from Voyager, the CH3D/H2 ratio obtained in this study implies a D/H ratio of 0.000018. This is in agreement with the interstellar medium value.
Targeting PIM kinase enhances the activity of sunitinib in renal cell carcinoma.
Mahalingam, D; Espitia, C M; Medina, E C; Esquivel, J A; Kelly, K R; Bearss, D; Choy, G; Taverna, P; Carew, J S; Giles, F J; Nawrocki, S T
2011-11-08
Upregulation of PIM kinase expression has been reported in many malignancies, suggesting that inhibition of PIM kinase activity may be an attractive therapeutic strategy. We hypothesised that inhibition of PIM kinase activity with SGI-1776, a novel small molecule inhibitor of PIM kinase activity, would reduce the viability of renal cell carcinoma (RCC) cells and enhance the activity of sunitinib. Immunoblotting, qRT-PCR, and gene expression arrays were carried out to identify genes modulated by SGI-1776 treatment. The anticancer activity of SGI-1776 and sunitinib was determined by viability and apoptosis assays and in tumour xenografts in vivo. Treatment with SGI-1776 led to a decrease in phosphorylated and total c-Myc levels, which resulted in the modulation of c-Myc target genes. SGI-1776 in combination with sunitinib induced a further reduction in c-Myc levels, which was associated with enhanced anticancer activity. siRNA-mediated knockdown of c-Myc demonstrated that its expression has a key role in regulating the sensitivity to the combination of SGI-1776 and sunitinib. Importantly, the combination significantly reduced tumour burden in two RCC xenograft models compared with single-agent therapy and was very well tolerated. These data indicate that targeting PIM kinase signalling is a promising treatment strategy for RCC. 2011 Cancer Research UK
Targeting PIM kinase enhances the activity of sunitinib in renal cell carcinoma
Mahalingam, D; Espitia, C M; Medina, E C; Esquivel, J A; Kelly, K R; Bearss, D; Choy, G; Taverna, P; Carew, J S; Giles, F J; Nawrocki, S T
2011-01-01
Background: Upregulation of PIM kinase expression has been reported in many malignancies, suggesting that inhibition of PIM kinase activity may be an attractive therapeutic strategy. We hypothesised that inhibition of PIM kinase activity with SGI-1776, a novel small molecule inhibitor of PIM kinase activity, would reduce the viability of renal cell carcinoma (RCC) cells and enhance the activity of sunitinib. Methods: Immunoblotting, qRT–PCR, and gene expression arrays were carried out to identify genes modulated by SGI-1776 treatment. The anticancer activity of SGI-1776 and sunitinib was determined by viability and apoptosis assays and in tumour xenografts in vivo. Results: Treatment with SGI-1776 led to a decrease in phosphorylated and total c-Myc levels, which resulted in the modulation of c-Myc target genes. SGI-1776 in combination with sunitinib induced a further reduction in c-Myc levels, which was associated with enhanced anticancer activity. siRNA-mediated knockdown of c-Myc demonstrated that its expression has a key role in regulating the sensitivity to the combination of SGI-1776 and sunitinib. Importantly, the combination significantly reduced tumour burden in two RCC xenograft models compared with single-agent therapy and was very well tolerated. Conclusion: These data indicate that targeting PIM kinase signalling is a promising treatment strategy for RCC. PMID:22015557
Large-scale Filamentary Structures around the Virgo Cluster Revisited
NASA Astrophysics Data System (ADS)
Kim, Suk; Rey, Soo-Chang; Bureau, Martin; Yoon, Hyein; Chung, Aeree; Jerjen, Helmut; Lisker, Thorsten; Jeong, Hyunjin; Sung, Eon-Chang; Lee, Youngdae; Lee, Woong; Chung, Jiwon
2016-12-01
We revisit the filamentary structures of galaxies around the Virgo cluster, exploiting a larger data set, based on the HyperLeda database, than previous studies. In particular, this includes a large number of low-luminosity galaxies, resulting in better sampled individual structures. We confirm seven known structures in the distance range 4 h -1 Mpc < SGY < 16 h -1 Mpc, now identified as filaments, where SGY is the axis of the supergalactic coordinate system roughly along the line of sight. The Hubble diagram of the filament galaxies suggests they are infalling toward the main body of the Virgo cluster. We propose that the collinear distribution of giant elliptical galaxies along the fundamental axis of the Virgo cluster is smoothly connected to two of these filaments (Leo II A and B). Behind the Virgo cluster (16 h -1 Mpc < SGY < 27 h -1 Mpc), we also identify a new filament elongated toward the NGC 5353/4 group (“NGC 5353/4 filament”) and confirm a sheet that includes galaxies from the W and M clouds of the Virgo cluster (“W-M sheet”). In the Hubble diagram, the NGC 5353/4 filament galaxies show infall toward the NGC 5353/4 group, whereas the W-M sheet galaxies do not show hints of gravitational influence from the Virgo cluster. The filamentary structures identified can now be used to better understand the generic role of filaments in the build-up of galaxy clusters at z ≈ 0.
Real-time volume rendering of 4D image using 3D texture mapping
NASA Astrophysics Data System (ADS)
Hwang, Jinwoo; Kim, June-Sic; Kim, Jae Seok; Kim, In Young; Kim, Sun Il
2001-05-01
Four dimensional image is 3D volume data that varies with time. It is used to express deforming or moving object in virtual surgery of 4D ultrasound. It is difficult to render 4D image by conventional ray-casting or shear-warp factorization methods because of their time-consuming rendering time or pre-processing stage whenever the volume data are changed. Even 3D texture mapping is used, repeated volume loading is also time-consuming in 4D image rendering. In this study, we propose a method to reduce data loading time using coherence between currently loaded volume and previously loaded volume in order to achieve real time rendering based on 3D texture mapping. Volume data are divided into small bricks and each brick being loaded is tested for similarity to one which was already loaded in memory. If the brick passed the test, it is defined as 3D texture by OpenGL functions. Later, the texture slices of the brick are mapped into polygons and blended by OpenGL blending functions. All bricks undergo this test. Continuously deforming fifty volumes are rendered in interactive time with SGI ONYX. Real-time volume rendering based on 3D texture mapping is currently available on PC.
Makhnovskii, P A; Kuzmin, I V; Nefedova, L N; Kima, A I
2016-01-01
Drosophila melanogaster is the only invertebrate that contains endogenous retroviruses, which are called errantiviruses. Two domesticated genes, Grp and Iris, which originate from errantivirus gag and env, respectively, have been found in the D. melanogaster genome. The functions performed by the genes in Drosophila are still unclear. To identify the functions of domesticated gag and env in the D. melanogaster genome, expression of Iris and Grp was studied in strains differing by the presence or absence of the functional gypsy errantivirus. In addition, the expression levels were measured after injection of gram-positive and gram-negative bacteria, which activate different immune response pathways, and exposure to various abiotic stress factors. The presence of functional D. melanogaster retrovirus gypsy was found to increase the Grp expression level in somatic tissues of the carcass, while exerting no effect on the Iris expression level. Activation of the immune response in D. melanogaster by bacteria Bacillus cereus increased the Grp expression level and did not affect Iris expression. As for the effects of abiotic stress factors (oxidative stress, starvation, and heat and cold stress), the Grp expression level increased in response to starvation in D. melanogaster females, and the Iris expression level was downregulated in heat shock and oxidative stress. Based on the findings, Grp was assumed to play a direct role in the immune response in D. melanogaster; Iris is not involved in immune responses, but and apparently performs a cell function that is inhibited in stress.
Thermoinactivation Mechanism of Glucose Isomerase
NASA Astrophysics Data System (ADS)
Lim, Leng Hong; Saville, Bradley A.
In this article, the mechanisms of thermoinactivation of glucose isomerase (GI) from Streptomyces rubiginosus (in soluble and immobilized forms) were investigated, particularly the contributions of thiol oxidation of the enzyme's cysteine residue and a "Maillard-like" reaction between the enzyme and sugars in high fructose corn syrup (HFCS). Soluble GI (SGI) was successfully immobilized on silica gel (13.5 μm particle size), with an activity yield between 20 and 40%. The immobilized GI (IGI) has high enzyme retention on the support during the glucose isomerization process. In batch reactors, SGI (half-life =145 h) was more stable than IGI (half-life=27 h) at 60°C in HFCS, whereas at 80°C, IGI (half-life=12 h) was more stable than SGI (half-life=5.2 h). IGI was subject to thiol oxidation at 60°C, which contributed to the enzyme's deactivation. IGI was subject to thiol oxidation at 80°C, but this did not contribute to the deactivation of the enzyme. SGI did not undergo thiol oxidation at 60°C, but at 80°C SGI underwent severe precipitation and thiol oxidation, which caused the enzyme to deactivate. Experimental results show that immobilization suppresses the destablizing effect of thiol oxidation on GI. A "Maillard-like" reaction between SGI and the sugars also caused SGI thermoinactivation at 60, 70, and 80°C, but had minimal effect on IGI. At 60 and 80°C, IGI had higher thermostability in continuous reactors than in batch reactors, possibily because of reduced contact with deleterious compounds in HFCS.
PLOT3D/AMES, APOLLO UNIX VERSION USING GMR3D (WITHOUT TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. The Apollo implementation of PLOT3D uses some of the capabilities of Apollo's 3-dimensional graphics hardware, but does not take advantage of the shading and hidden line/surface removal capabilities of the Apollo DN10000. Although this implementation does not offer a capability for putting text on plots, it does support the use of a mouse to translate, rotate, or zoom in on views. The version 3.6b+ Apollo implementations of PLOT3D (ARC-12789) and PLOT3D/TURB3D (ARC-12785) were developed for use on Apollo computers running UNIX System V with BSD 4.3 extensions and the graphics library GMR3D Version 2.0. The standard distribution media for each of these programs is a 9-track, 6250 bpi magnetic tape in TAR format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: 1) generic UNIX Supercomputer and IRIS, suitable for CRAY 2/UNICOS, CONVEX, and Alliant with remote IRIS 2xxx/3xxx or IRIS 4D (ARC-12779, ARC-12784); 2) VAX computers running VMS Version 5.0 and DISSPLA Version 11.0 (ARC-12777, ARC-12781); 3) generic UNIX and DISSPLA Version 11.0 (ARC-12788, ARC-12778); and (4) Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D workstations (ARC-12783, ARC-12782). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo and GMR3D are trademarks of Hewlett-Packard, Incorporated. UNIX is a registered trademark of AT&T.
PLOT3D/AMES, APOLLO UNIX VERSION USING GMR3D (WITH TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. The Apollo implementation of PLOT3D uses some of the capabilities of Apollo's 3-dimensional graphics hardware, but does not take advantage of the shading and hidden line/surface removal capabilities of the Apollo DN10000. Although this implementation does not offer a capability for putting text on plots, it does support the use of a mouse to translate, rotate, or zoom in on views. The version 3.6b+ Apollo implementations of PLOT3D (ARC-12789) and PLOT3D/TURB3D (ARC-12785) were developed for use on Apollo computers running UNIX System V with BSD 4.3 extensions and the graphics library GMR3D Version 2.0. The standard distribution media for each of these programs is a 9-track, 6250 bpi magnetic tape in TAR format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: 1) generic UNIX Supercomputer and IRIS, suitable for CRAY 2/UNICOS, CONVEX, and Alliant with remote IRIS 2xxx/3xxx or IRIS 4D (ARC-12779, ARC-12784); 2) VAX computers running VMS Version 5.0 and DISSPLA Version 11.0 (ARC-12777, ARC-12781); 3) generic UNIX and DISSPLA Version 11.0 (ARC-12788, ARC-12778); and (4) Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D workstations (ARC-12783, ARC-12782). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo and GMR3D are trademarks of Hewlett-Packard, Incorporated. UNIX is a registered trademark of AT&T.
Parallelization of Lower-Upper Symmetric Gauss-Seidel Method for Chemically Reacting Flow
NASA Technical Reports Server (NTRS)
Yoon, Seokkwan; Jost, Gabriele; Chang, Sherry
2005-01-01
Development of technologies for exploration of the solar system has revived an interest in computational simulation of chemically reacting flows since planetary probe vehicles exhibit non-equilibrium phenomena during the atmospheric entry of a planet or a moon as well as the reentry to the Earth. Stability in combustion is essential for new propulsion systems. Numerical solution of real-gas flows often increases computational work by an order-of-magnitude compared to perfect gas flow partly because of the increased complexity of equations to solve. Recently, as part of Project Columbia, NASA has integrated a cluster of interconnected SGI Altix systems to provide a ten-fold increase in current supercomputing capacity that includes an SGI Origin system. Both the new and existing machines are based on cache coherent non-uniform memory access architecture. Lower-Upper Symmetric Gauss-Seidel (LU-SGS) relaxation method has been implemented into both perfect and real gas flow codes including Real-Gas Aerodynamic Simulator (RGAS). However, the vectorized RGAS code runs inefficiently on cache-based shared-memory machines such as SGI system. Parallelization of a Gauss-Seidel method is nontrivial due to its sequential nature. The LU-SGS method has been vectorized on an oblique plane in INS3D-LU code that has been one of the base codes for NAS Parallel benchmarks. The oblique plane has been called a hyperplane by computer scientists. It is straightforward to parallelize a Gauss-Seidel method by partitioning the hyperplanes once they are formed. Another way of parallelization is to schedule processors like a pipeline using software. Both hyperplane and pipeline methods have been implemented using openMP directives. The present paper reports the performance of the parallelized RGAS code on SGI Origin and Altix systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Painter, J.; McCormick, P.; Krogh, M.
This paper presents the ACL (Advanced Computing Lab) Message Passing Library. It is a high throughput, low latency communications library, based on Thinking Machines Corp.`s CMMD, upon which message passing applications can be built. The library has been implemented on the Cray T3D, Thinking Machines CM-5, SGI workstations, and on top of PVM.
PLOT3D/AMES, DEC VAX VMS VERSION USING DISSPLA (WITHOUT TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P. G.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. The VAX/VMS/DISSPLA implementation of PLOT3D supports 2-D polygons as well as 2-D and 3-D lines, but does not support graphics features requiring 3-D polygons (shading and hidden line removal, for example). Views can be manipulated using keyboard commands. This version of PLOT3D is potentially able to produce files for a variety of output devices; however, site-specific capabilities will vary depending on the device drivers supplied with the user's DISSPLA library. If ARCGRAPH (ARC-12350) is installed on the user's VAX, the VMS/DISSPLA version of PLOT3D can also be used to create files for use in GAS (Graphics Animation System, ARC-12379), an IRIS program capable of animating and recording images on film. The version 3.6b+ VMS/DISSPLA implementations of PLOT3D (ARC-12777) and PLOT3D/TURB3D (ARC-12781) were developed for use on VAX computers running VMS Version 5.0 and DISSPLA Version 11.0. The standard distribution media for each of these programs is a 9-track, 6250 bpi magnetic tape in DEC VAX BACKUP format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: (1) generic UNIX Supercomputer and IRIS, suitable for CRAY 2/UNICOS, CONVEX, and Alliant with remote IRIS 2xxx/3xxx or IRIS 4D (ARC-12779, ARC-12784); (2) Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D (ARC-12783, ARC12782); (3) generic UNIX and DISSPLA Version 11.0 (ARC-12788, ARC-12778); and (4) Apollo computers running UNIX and GMR3D Version 2.0 (ARC-12789, ARC-12785 which have no capabilities to put text on plots). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo and GMR3D are trademarks of Hewlett-Packard, Incorporated. UNIX is a registered trademark of AT&T.
PLOT3D/AMES, DEC VAX VMS VERSION USING DISSPLA (WITH TURB3D)
NASA Technical Reports Server (NTRS)
Buning, P.
1994-01-01
PLOT3D is an interactive graphics program designed to help scientists visualize computational fluid dynamics (CFD) grids and solutions. Today, supercomputers and CFD algorithms can provide scientists with simulations of such highly complex phenomena that obtaining an understanding of the simulations has become a major problem. Tools which help the scientist visualize the simulations can be of tremendous aid. PLOT3D/AMES offers more functions and features, and has been adapted for more types of computers than any other CFD graphics program. Version 3.6b+ is supported for five computers and graphic libraries. Using PLOT3D, CFD physicists can view their computational models from any angle, observing the physics of problems and the quality of solutions. As an aid in designing aircraft, for example, PLOT3D's interactive computer graphics can show vortices, temperature, reverse flow, pressure, and dozens of other characteristics of air flow during flight. As critical areas become obvious, they can easily be studied more closely using a finer grid. PLOT3D is part of a computational fluid dynamics software cycle. First, a program such as 3DGRAPE (ARC-12620) helps the scientist generate computational grids to model an object and its surrounding space. Once the grids have been designed and parameters such as the angle of attack, Mach number, and Reynolds number have been specified, a "flow-solver" program such as INS3D (ARC-11794 or COS-10019) solves the system of equations governing fluid flow, usually on a supercomputer. Grids sometimes have as many as two million points, and the "flow-solver" produces a solution file which contains density, x- y- and z-momentum, and stagnation energy for each grid point. With such a solution file and a grid file containing up to 50 grids as input, PLOT3D can calculate and graphically display any one of 74 functions, including shock waves, surface pressure, velocity vectors, and particle traces. PLOT3D's 74 functions are organized into five groups: 1) Grid Functions for grids, grid-checking, etc.; 2) Scalar Functions for contour or carpet plots of density, pressure, temperature, Mach number, vorticity magnitude, helicity, etc.; 3) Vector Functions for vector plots of velocity, vorticity, momentum, and density gradient, etc.; 4) Particle Trace Functions for rake-like plots of particle flow or vortex lines; and 5) Shock locations based on pressure gradient. TURB3D is a modification of PLOT3D which is used for viewing CFD simulations of incompressible turbulent flow. Input flow data consists of pressure, velocity and vorticity. Typical quantities to plot include local fluctuations in flow quantities and turbulent production terms, plotted in physical or wall units. PLOT3D/TURB3D includes both TURB3D and PLOT3D because the operation of TURB3D is identical to PLOT3D, and there is no additional sample data or printed documentation for TURB3D. Graphical capabilities of PLOT3D version 3.6b+ vary among the implementations available through COSMIC. Customers are encouraged to purchase and carefully review the PLOT3D manual before ordering the program for a specific computer and graphics library. There is only one manual for use with all implementations of PLOT3D, and although this manual generally assumes that the Silicon Graphics Iris implementation is being used, informative comments concerning other implementations appear throughout the text. With all implementations, the visual representation of the object and flow field created by PLOT3D consists of points, lines, and polygons. Points can be represented with dots or symbols, color can be used to denote data values, and perspective is used to show depth. Differences among implementations impact the program's ability to use graphical features that are based on 3D polygons, the user's ability to manipulate the graphical displays, and the user's ability to obtain alternate forms of output. The VAX/VMS/DISSPLA implementation of PLOT3D supports 2-D polygons as well as 2-D and 3-D lines, but does not support graphics features requiring 3-D polygons (shading and hidden line removal, for example). Views can be manipulated using keyboard commands. This version of PLOT3D is potentially able to produce files for a variety of output devices; however, site-specific capabilities will vary depending on the device drivers supplied with the user's DISSPLA library. If ARCGRAPH (ARC-12350) is installed on the user's VAX, the VMS/DISSPLA version of PLOT3D can also be used to create files for use in GAS (Graphics Animation System, ARC-12379), an IRIS program capable of animating and recording images on film. The version 3.6b+ VMS/DISSPLA implementations of PLOT3D (ARC-12777) and PLOT3D/TURB3D (ARC-12781) were developed for use on VAX computers running VMS Version 5.0 and DISSPLA Version 11.0. The standard distribution media for each of these programs is a 9-track, 6250 bpi magnetic tape in DEC VAX BACKUP format. Customers purchasing one implementation version of PLOT3D or PLOT3D/TURB3D will be given a $200 discount on each additional implementation version ordered at the same time. Version 3.6b+ of PLOT3D and PLOT3D/TURB3D are also supported for the following computers and graphics libraries: (1) generic UNIX Supercomputer and IRIS, suitable for CRAY 2/UNICOS, CONVEX, and Alliant with remote IRIS 2xxx/3xxx or IRIS 4D (ARC-12779, ARC-12784); (2) Silicon Graphics IRIS 2xxx/3xxx or IRIS 4D (ARC-12783, ARC12782); (3) generic UNIX and DISSPLA Version 11.0 (ARC-12788, ARC-12778); and (4) Apollo computers running UNIX and GMR3D Version 2.0 (ARC-12789, ARC-12785 which have no capabilities to put text on plots). Silicon Graphics Iris, IRIS 4D, and IRIS 2xxx/3xxx are trademarks of Silicon Graphics Incorporated. VAX and VMS are trademarks of Digital Electronics Corporation. DISSPLA is a trademark of Computer Associates. CRAY 2 and UNICOS are trademarks of CRAY Research, Incorporated. CONVEX is a trademark of Convex Computer Corporation. Alliant is a trademark of Alliant. Apollo and GMR3D are trademarks of Hewlett-Packard, Incorporated. UNIX is a registered trademark of AT&T.
DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (SUN VERSION)
NASA Technical Reports Server (NTRS)
Rogers, J. L.
1994-01-01
Many engineering systems are large and multi-disciplinary. Before the design of new complex systems such as large space platforms can begin, the possible interactions among subsystems and their parts must be determined. Once this is completed the proposed system can be decomposed to identify its hierarchical structure. DeMAID (A Design Manager's Aid for Intelligent Decomposition) is a knowledge-based system for ordering the sequence of modules and identifying a possible multilevel structure for the design problem. DeMAID displays the modules in an N x N matrix format (called a design structure matrix) where a module is any process that requires input and generates an output. (Modules which generate an output but do not require an input, such as an initialization process, are also acceptable.) Although DeMAID requires an investment of time to generate and refine the list of modules for input, it could save a considerable amount of money and time in the total design process, particularly in new design problems where the ordering of the modules has not been defined. The decomposition of a complex design system into subsystems requires the judgement of the design manager. DeMAID reorders and groups the modules based on the links (interactions) among the modules, helping the design manager make decomposition decisions early in the design cycle. The modules are grouped into circuits (the subsystems) and displayed in an N x N matrix format. Feedback links, which indicate an iterative process, are minimized and only occur within a subsystem. Since there are no feedback links among the circuits, the circuits can be displayed in a multilevel format. Thus, a large amount of information is reduced to one or two displays which are stored for later retrieval and modification. The design manager and leaders of the design teams then have a visual display of the design problem and the intricate interactions among the different modules. The design manager could save a substantial amount of time if circuits on the same level of the multilevel structure are executed in parallel. DeMAID estimates the time savings based on the number of available processors. In addition to decomposing the system into subsystems, DeMAID examines the dependencies of a problem with independent variables and dependant functions. A dependency matrix is created to show the relationship. DeMAID is based on knowledge base techniques to provide flexibility and ease in adding new capabilities. Although DeMAID was originally written for design problems, it has proven to be very general in solving any problem which contains modules (processes) which take an input and generate an output. For example, one group is applying DeMAID to gain understanding of the data flow of a very large computer program. In this example, the modules are the subroutines of the program. The design manager begins the design of a system by determining the level of modules which need to be ordered. The level is the "granularity" of the problem. For example, the design manager may wish to examine disciplines (a coarse model), analysis programs, or the data level (a fine model). Once the system is divided into these modules, each module's input and output is determined, creating a data file for input to the main program. DeMAID is executed through a system of menus. The user has the choice to plan, schedule, display the N x N matrix, display the multilevel organization, or examine the dependency matrix. The main program calls a subroutine which reads a rule file and a data file, asserts facts into the knowledge base, and executes the inference engine of the artificial intelligence/expert systems program, CLIPS (C Language Integrated Production System). To determine the effects of changes in the design process, DeMAID includes a trace effects feature. There are two methods available to trace the effects of a change in the design process. The first method traces forward through the outputs to determine the effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.
DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (MACINTOSH VERSION)
NASA Technical Reports Server (NTRS)
Rogers, J. L.
1994-01-01
Many engineering systems are large and multi-disciplinary. Before the design of new complex systems such as large space platforms can begin, the possible interactions among subsystems and their parts must be determined. Once this is completed the proposed system can be decomposed to identify its hierarchical structure. DeMAID (A Design Manager's Aid for Intelligent Decomposition) is a knowledge-based system for ordering the sequence of modules and identifying a possible multilevel structure for the design problem. DeMAID displays the modules in an N x N matrix format (called a design structure matrix) where a module is any process that requires input and generates an output. (Modules which generate an output but do not require an input, such as an initialization process, are also acceptable.) Although DeMAID requires an investment of time to generate and refine the list of modules for input, it could save a considerable amount of money and time in the total design process, particularly in new design problems where the ordering of the modules has not been defined. The decomposition of a complex design system into subsystems requires the judgement of the design manager. DeMAID reorders and groups the modules based on the links (interactions) among the modules, helping the design manager make decomposition decisions early in the design cycle. The modules are grouped into circuits (the subsystems) and displayed in an N x N matrix format. Feedback links, which indicate an iterative process, are minimized and only occur within a subsystem. Since there are no feedback links among the circuits, the circuits can be displayed in a multilevel format. Thus, a large amount of information is reduced to one or two displays which are stored for later retrieval and modification. The design manager and leaders of the design teams then have a visual display of the design problem and the intricate interactions among the different modules. The design manager could save a substantial amount of time if circuits on the same level of the multilevel structure are executed in parallel. DeMAID estimates the time savings based on the number of available processors. In addition to decomposing the system into subsystems, DeMAID examines the dependencies of a problem with independent variables and dependant functions. A dependency matrix is created to show the relationship. DeMAID is based on knowledge base techniques to provide flexibility and ease in adding new capabilities. Although DeMAID was originally written for design problems, it has proven to be very general in solving any problem which contains modules (processes) which take an input and generate an output. For example, one group is applying DeMAID to gain understanding of the data flow of a very large computer program. In this example, the modules are the subroutines of the program. The design manager begins the design of a system by determining the level of modules which need to be ordered. The level is the "granularity" of the problem. For example, the design manager may wish to examine disciplines (a coarse model), analysis programs, or the data level (a fine model). Once the system is divided into these modules, each module's input and output is determined, creating a data file for input to the main program. DeMAID is executed through a system of menus. The user has the choice to plan, schedule, display the N x N matrix, display the multilevel organization, or examine the dependency matrix. The main program calls a subroutine which reads a rule file and a data file, asserts facts into the knowledge base, and executes the inference engine of the artificial intelligence/expert systems program, CLIPS (C Language Integrated Production System). To determine the effects of changes in the design process, DeMAID includes a trace effects feature. There are two methods available to trace the effects of a change in the design process. The first method traces forward through the outputs to determine the effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.
1984-10-01
16 4.2 Solid Waste Receiving and Storage Area ........................ 17 4.3 Equipment Location and Spacing...10OROS (Ccr4n-ifl. **,0d. d - -eet -.d tdonfffy by bltk -P-+) HRI, RAM, Human factors, HRI design, IRI safety, solid waste , energy recovery 10 AOSTNACT...health and safety hazards to individuals hand-sorting the conglomerate of solid waste , the potential of dangerous substances and inflammable or ex
Park, Yu-Kyoung; Hong, Victor Sukbong; Lee, Tae-Yoon; Lee, Jinho; Choi, Jong-Soon; Park, Dong-Soon; Park, Gi-Young; Jang, Byeong-Churl
2016-01-01
The proviral integration site for moloney murine leukemia virus (Pim) kinases, consisting of Pim-1, Pim-2 and Pim-3, belongs to a family of serine/threonine kinases that are involved in controlling cell growth and differentiation. Pim kinases are emerging as important mediators of adipocyte differentiation. SGI-1776, an inhibitor of Pim kinases, is widely used to assess the physiological roles of Pim kinases, particularly cell functions. In the present study, we examined the effects of SGI-1776 on adipogenesis. The anti‑adipogenic effect of SGI‑1776 was measured by Oil Red O staining and AdipoRed assays. The effect of SGI‑1776 on the growth of 3T3‑L1 adipocytes was determined by cell count analysis. The effects of SGI‑1776 on the protein and mRNA expression of adipogenesis-related proteins and adipokines in 3T3‑L1 adipocytes were also evaluated by western blot analysis and RT‑PCR, respectively. Notably, SGI-1776 markedly inhibited lipid accumulation during the differentiation of 3T3-L1 preadipocytes into adipocytes. On a mechanistic level, SGI-1776 inhibited not only the expression of CCAAT/enhancer-binding protein-α (C/EBP-α), peroxisome proliferator-activated receptor-γ (PPAR-γ) and fatty acid synthase (FAS), but also the phosphorylation of signal transducer and activator of transcription-3 (STAT-3). Moreover, SGI-1776 decreased the expression of adipokines, including the expression of leptin and regulated on activation, normal T cell expressed and secreted (RANTES) during adipocyte differentiation. These findings demonstrate that SGI-1776 inhibits adipogenesis by downregulating the expression and/or phosphorylation levels of C/EBP-α, PPAR-γ, FAS and STAT-3.
Estimating Groundwater Development area in Jianan Plain using Standardized Groundwater Index
NASA Astrophysics Data System (ADS)
Yu, Chang Hsiang; Haw, Lee Cheng
2017-04-01
Taiwan has been facing severe water crises in recent years owing to the effects of extreme weather conditions. Changes in precipitation patterns have also made the drought phenomenon increasingly prominent, which has indirectly affected groundwater recharge. Hence, in the present study, long-term monitoring data were collected from the study area of the Jianan plain. The standardized groundwater index (SGI) and was then used to analyse the region's drought characteristics. To analyse the groundwater level by using SGI, making SGI180 groundwater level be the medium water crises, and SGI360 groundwater level be the extreme water crises. Through the different water crises signal in SGI180 and SGI360, we divide groundwater in Jianan plain into two sections. Thereby the water crises indicators establishing groundwater level standard line in Jianan Plain, then using the groundwater level standard line to find the study area where could be groundwater development area in Jianan plain. Taking into account relatively more water scarcity in dry season, so the study screen out another emergency backup groundwater development area, but the long-term groundwater development area is still as a priority development area. After finding suitable locations, groundwater modeling systems(GMS) software is used to simulate our sites to evaluate development volume. Finally, the result of study will help the government to grasp the water shortage situation immediately and solve the problem of water resources deployment.
NASA Technical Reports Server (NTRS)
Frumkin, Michael; Yan, Jerry
1999-01-01
We present an HPF (High Performance Fortran) implementation of ARC3D code along with the profiling and performance data on SGI Origin 2000. Advantages and limitations of HPF as a parallel programming language for CFD applications are discussed. For achieving good performance results we used the data distributions optimized for implementation of implicit and explicit operators of the solver and boundary conditions. We compare the results with MPI and directive based implementations.
Andersen, Douglas
2016-01-01
Knowledge of the factors affecting the vigor of desert riparian trees is important for their conservation and management. I used multiple regression to assess effects of streamflow and climate (12–14 years of data) or climate alone (up to 60 years of data) on radial growth of clonal narrowleaf cottonwood (Populus angustifolia), a foundation species in the arid, Closed Basin portion of the San Luis Valley, Colorado. I collected increment cores from trees (14–90 cm DBH) at four sites along each of Sand and Deadman creeks (total N = 85), including both perennial and ephemeral reaches. Analyses on trees <110 m from the stream channel explained 33–64% of the variation in standardized growth index (SGI) over the period having discharge measurements. Only 3 of 7 models included a streamflow variable; inclusion of prior-year conditions was common. Models for trees farther from the channel or over a deep water table explained 23–71% of SGI variability, and 4 of 5 contained a streamflow variable. Analyses using solely climate variables over longer time periods explained 17–85% of SGI variability, and 10 of 12 included a variable indexing summer precipitation. Three large, abrupt shifts in recent decades from wet to dry conditions (indexed by a seasonal Palmer Drought Severity Index) coincided with dramatically reduced radial growth. Each shift was presumably associated with branch dieback that produced a legacy effect apparent in many SGI series: uncharacteristically low SGI in the year following the shift. My results suggest trees in locations distant from the active channel rely on the regional shallow unconfined aquifer, summer rainfall, or both to meet water demands. The landscape-level differences in the water supplies sustaining these trees imply variable effects from shifts in winter-versus monsoon-related precipitation, and from climate change versus streamflow or groundwater management.
Natarajan, Karthika; Bhullar, Jasjeet; Shukla, Suneet; Burcu, Mehmet; Chen, Zhe-Sheng; Ambudkar, Suresh V.; Baer, Maria R.
2013-01-01
Overexpression of the ATP-binding cassette (ABC) drug efflux proteins P-glycoprotein (ABCB1) and breast cancer resistance protein (ABCG2) on malignant cells is associated with inferior chemotherapy outcomes. Both, ABCB1 and ABCG2, are substrates of the serine/threonine kinase Pim-1; Pim-1 knockdown decreases their cell surface expression, but SGI-1776, the first clinically tested Pim inhibitor, was shown to reverse drug resistance by directly inhibiting ABCB1-mediated transport. We sought to characterize Pim-1-dependent and -independent effects of SGI-1776 on drug resistance. SGI-1776 at the Pim-1-inhibitory and non-cytotoxic concentration of 1 μM decreased the IC50s of the ABCG2 and ABCB1 substrate drugs in cytotoxicity assays in resistant cells, with no effect on the IC50 of non-substrate drug, nor in parental cells. SGI-1776 also increased apoptosis of cells overexpressing ABCG2 or ABCB1 exposed to substrate chemotherapy drugs and decreased their colony formation in the presence of substrate, but not non-substrate, drugs, with no effect on parental cells. SGI-1776 decreased ABCB1 and ABCG2 surface expression on K562/ABCB1 and K562/ABCG2 cells, respectively, with Pim-1 overexpression, but not HL60/VCR and 8226/MR20 cells, with lower-level Pim-1 expression. Finally, SGI-1776 inhibited uptake of ABCG2 and ABCB1 substrates in a concentration-dependent manner irrespective of Pim-1 expression, inhibited ABCB1 and ABCG2 photoaffinity labeling with the transport substrate [125I]iodoarylazidoprazosin ([125I]IAAP) and stimulated ABCB1 and ABCG2 ATPase activity. Thus SGI-1776 decreases cell surface expression of ABCB1 and ABCG2 and inhibits drug transport by Pim-1-dependent and -independent mechanisms, respectively. Decrease in ABCB1 and ABCG2 cell surface expression mediated by Pim-1 inhibition represents a novel mechanism of chemosensitization. PMID:23261525
Natarajan, Karthika; Bhullar, Jasjeet; Shukla, Suneet; Burcu, Mehmet; Chen, Zhe-Sheng; Ambudkar, Suresh V; Baer, Maria R
2013-02-15
Overexpression of the ATP-binding cassette (ABC) drug efflux proteins P-glycoprotein (ABCB1) and breast cancer resistance protein (ABCG2) on malignant cells is associated with inferior chemotherapy outcomes. Both, ABCB1 and ABCG2, are substrates of the serine/threonine kinase Pim-1; Pim-1 knockdown decreases their cell surface expression, but SGI-1776, the first clinically tested Pim inhibitor, was shown to reverse drug resistance by directly inhibiting ABCB1-mediated transport. We sought to characterize Pim-1-dependent and -independent effects of SGI-1776 on drug resistance. SGI-1776 at the Pim-1-inhibitory and non-cytotoxic concentration of 1 μM decreased the IC(50)s of the ABCG2 and ABCB1 substrate drugs in cytotoxicity assays in resistant cells, with no effect on the IC(50) of non-substrate drug, nor in parental cells. SGI-1776 also increased apoptosis of cells overexpressing ABCG2 or ABCB1 exposed to substrate chemotherapy drugs and decreased their colony formation in the presence of substrate, but not non-substrate, drugs, with no effect on parental cells. SGI-1776 decreased ABCB1 and ABCG2 surface expression on K562/ABCB1 and K562/ABCG2 cells, respectively, with Pim-1 overexpression, but not HL60/VCR and 8226/MR20 cells, with lower-level Pim-1 expression. Finally, SGI-1776 inhibited uptake of ABCG2 and ABCB1 substrates in a concentration-dependent manner irrespective of Pim-1 expression, inhibited ABCB1 and ABCG2 photoaffinity labeling with the transport substrate [(125)I]iodoarylazidoprazosin ([(125)I]IAAP) and stimulated ABCB1 and ABCG2 ATPase activity. Thus SGI-1776 decreases cell surface expression of ABCB1 and ABCG2 and inhibits drug transport by Pim-1-dependent and -independent mechanisms, respectively. Decrease in ABCB1 and ABCG2 cell surface expression mediated by Pim-1 inhibition represents a novel mechanism of chemosensitization. Copyright © 2012 Elsevier Inc. All rights reserved.
77 FR 26751 - Integrated Risk Information System (IRIS); Announcement of 2012 Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-07
...-41-4. ethylene oxide (cancer) 75-21-8. formaldehyde \\1\\ 50-00-0. hexabromocyclododecane (mixed 3194...\\. octamethylcyclotetrasiloxane 556-67-2 FY13. (D4) \\2\\. 1,2-dichloroethane (ethylene 107-06-2 FY14. dichloride) \\1,3...
Storage Ring Technology for Free Electron Lasers.
1984-04-01
aperture of the iris is controlled from outsideplac d in a vacuutm chamber. The pressure inside this the vacuum chamber. The rotational motion needed... motions (two translations and The mechanical assembly of these various parts is one rotational for the iris aperture) are severe in this shown in Fig. 3...expression -4- for the small signal gain spectrum, including the phase shift of the slowly varying wave z V y(9) It is clear from (8) and (9) that care must
Luetkemeyer, Anne F; Kendall, Michelle A; Nyirenda, Mulinda; Wu, Xingye; Ive, Prudence; Benson, Constance A; Andersen, Janet W; Swindells, Susan; Sanne, Ian M; Havlir, Diane V; Kumwenda, Johnstone
2014-04-01
Earlier initiation of antiretroviral therapy (ART) in HIV-tuberculosis (TB) is associated with increased immune reconstitution inflammatory syndrome (IRIS). The severity, frequency, and complications of TB IRIS were evaluated in A5221, a randomized trial of earlier ART (within 2 weeks after TB treatment initiation) vs. later ART (8-12 weeks after TB treatment) in HIV-infected patients starting TB treatment. In 806 participants, TB IRIS was defined using published clinical criteria. Cases were classified as severe (hospitalization/death), moderate (corticosteroid use/invasive procedure), or mild (no hospitalization/procedures/steroids). Fisher exact, Wilcoxon, and log-rank tests were used for comparisons. TB IRIS occurred in 61 (7.6%) patients: 10.4% in earlier vs. 4.7% in later ART, 11.5% with CD4 <50 vs. 5.4% with CD4 ≥50 cells per cubic millimeter. The CD4/ART arm interaction was significant, P = 0.014, with 44.3% of TB IRIS occurring with CD4 <50 and earlier ART. TB IRIS occurred sooner with earlier vs. later ART initiation, at a median of 29 vs. 82 days after TB treatment initiation (P < 0.001). IRIS manifestations included lymphadenopathy (59.0%), constitutional symptoms (54.1%), and radiographic changes (41.0%); central nervous system TB IRIS was uncommon (6.6%). TB IRIS was mild in 27.9%, moderate in 41.0%, and severe in 31.1%. No TB IRIS-associated deaths occurred. IRIS management required ≥1 invasive procedures in 34.4%, hospitalization in 31.1%, and corticosteroids in 54.1%. TB IRIS was more frequent with earlier ART initiation and CD4 <50 cells per cubic millimeter. As ART is implemented earlier in HIV-TB coinfection, programs will require the diagnostic capabilities, clinical resources, and training necessary to manage TB IRIS.
Luo, C C; Chen, H M; Chiu, C H; Lin, J N; Chen, J C
2001-07-01
Subclinical intestinal ischemia-reperfusion injury (IRI) causes an increase in mucosal permeability and may represent an early event in the pathogenesis of necrotizing enterocolitis in premature infants. Previous studies suggested that continuous, endogenous formation of nitric oxide (NO) maintains the mucosal integrity of the intestine, thus protecting the gut from injuries from blood-borne toxins and tissue-destructive mediators. This study was undertaken to assess whether the inhibition of NO production causes an increase in intestinal permeability in rats following IRI. Sprague-Dawley rats weighing 200-300 g were divided into 4 groups: (1) untreated group (normal control); (2) ischemia-reperfusion group; (3) early N(G)-nitro-L-arginine methyl ester (L-NAME), a specific inhibitor of NO production, treatment group, and (4) late L-NAME treatment group. Transient IRI was induced by 30-min occlusion, followed by reperfusion of the isolated ileal loop. The L-NAME was administered 15 min before and after mesenteric ischemia as a 25-mg/kg bolus. Fluorescein isothiocyanate-dextran (FITC-D) was used to quantitatively assess the alteration in mucosal permeability of the intestine. There was no significant increase in the portal vein FITC-D level among normal controls, ischemia-reperfusion group and late L-NAME-treated group, but there was an approximately 6-fold increase in the early L-NAME treatment group. The pathological features of the intestine following IRI include denudation of the villus epithelium and reduction of villus height, associated with marked inflammatory cell infiltration over the lamina propria. These results suggest that endogenous NO may play a role in the protecting intestinal integrity after IRI. Copyright 2001 S. Karger AG, Basel
Immunopathology of immune reconstitution inflammatory syndrome in Whipple's disease.
Moos, Verena; Feurle, Gerhard E; Schinnerling, Katina; Geelhaar, Anika; Friebel, Julian; Allers, Kristina; Moter, Annette; Kikhney, Judith; Loddenkemper, Christoph; Kühl, Anja A; Erben, Ulrike; Fenollar, Florence; Raoult, Didier; Schneider, Thomas
2013-03-01
During antimicrobial treatment of classic Whipple's disease (CWD), the chronic systemic infection with Tropheryma whipplei, immune reconstitution inflammatory syndrome (IRIS), is a serious complication. The aim of our study was to characterize the immunological processes underlying IRIS in CWD. Following the definition of IRIS, we describe histological features of IRIS and immunological parameters of 24 CWD IRIS patients, 189 CWD patients without IRIS, and 89 healthy individuals. T cell reconstitution, Th1 reactivity, and the phenotype of T cells were described in the peripheral blood, and infiltration of CD4(+) T cells and regulatory T cells in the duodenal mucosa was determined. During IRIS, tissues were heavily infiltrated by CD3(+), predominantly CD45RO(+)CD4(+) T cells. In the periphery, initial reduction of CD4(+) cell counts and their reconstitution on treatment was more pronounced in CWD patients with IRIS than in those without IRIS. The ratio of activated and regulatory CD4(+) T cells, nonspecific Th1 reactivity, and the proportion of naive among CD4(+) T cells was high, whereas serum IL-10 was low during IRIS. T. whipplei-specific Th1 reactivity remained suppressed before and after emergence of IRIS. The findings that IRIS in CWD mainly are mediated by nonspecific activation of CD4(+) T cells and that it is not sufficiently counterbalanced by regulatory T cells indicate that flare-up of pathogen-specific immunoreactivity is not instrumental in the pathogenesis of IRIS in CWD.
Zhou, Huaying; He, Yan; Chen, Zi; He, Bo; He, Mei
2014-01-01
Abstract The present study investigated the immunological pathogenesis of immune reconstitution inflammatory syndrome (IRIS) in acquired immunodeficiency syndrome (AIDS) patients undergoing highly active antiretroviral therapy (HAART). A total of 238 patients with AIDS who received initial HAART were included in this prospective cohort study. Blood samples were collected immediately, at baseline, at week 12, and at week 24 after initial HAART and at the onset of IRIS. Lymphocyte subsets, Th1 and Th2 cytokines, and interleukin (IL)-7 levels were measured by flow cytometry or ELISA. Among the 238 patients with AIDS who received HAART, 47 patients developed IRIS. The percentages of CD4+ and CD8+ naive, memory, and activated cells exhibited no significant differences between AIDS patients with and without IRIS 24 weeks after initial HAART. The percentage of CD4+CD25+Foxp3+ regulatory T cells was lower in IRIS patients than in non-IRIS patients before HAART, 12 weeks after HAART, 24 weeks after HAART, and at the onset of IRIS. IL-2 and interferon (IFN)-γ levels were significantly higher at week 4 and at the onset of IRIS in IRIS patients than in non-IRIS patients. In contrast, IL-4 and IL-10 levels were significantly lower at week 4 and at the onset of IRIS in IRIS patients than in non-IRIS patients. Plasma IL-7 decreased gradually with the progression of HAART. The level of IL-7 was higher in IRIS patients than in non-IRIS patients at all follow-up time points. An imbalance of Th1/Th2 cytokines, a consistently low CD+CD25+Fox3+ percentage, and a high IL-7 level may be crucial in the pathogenesis of IRIS in AIDS patients who had received HAART. PMID:25131160
Narendran, Gopalan; Kavitha, Dhanasekaran; Karunaianantham, Ramesh; Gil-Santana, Leonardo; Almeida-Junior, Jilson L; Reddy, Sirasanambatti Devarajulu; Kumar, Marimuthu Makesh; Hemalatha, Haribabu; Jayanthi, Nagesh Nalini; Ravichandran, Narayanan; Krishnaraja, Raja; Prabhakar, Angamuthu; Manoharan, Tamizhselvan; Nithyananthan, Lokeswaran; Arjunan, Gunasundari; Natrajan, Mohan; Swaminathan, Soumya; Andrade, Bruno B
2016-01-01
Paradoxical tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) is an inflammatory phenomenon complicating HIV management in coincidental tuberculosis (TB) infection, upon immune reconstitution driven by antiretroviral therapy (ART). Leukotriene A4 hydroxylase (LTA4H), an enzyme which converts LTA4 to LTB4, regulates the balance between the anti-inflammatory lipoxins and pro-inflammatory LTB4, with direct implications in TB-driven inflammation. In humans, a single nucleotide polymorphism (SNP) in the LTA4H promoter which regulates its transcriptional activity (rs17525495) has been identified and described to impact clinical severity of TB presentation and response to corticosteroid therapy. Notably, the role of LTA4H on TB-IRIS has not been previously evaluated. Here, we performed an exploratory investigation testing the association of LTA4H polymorphism with respect to frequency of TB-IRIS occurrence and severity of TB-IRIS presentation in HIV-TB co-infected individuals. Genotypic evaluation of the LTA4H enzyme from available samples was retrospectively correlated with clinical data captured in case sheets including IRIS details. The cohort included patients recruited from a prospective cohort study nested within a randomized clinical trial (NCT0933790) of ART-naïve HIV+ patients with newly diagnosed rifampicin sensitive pulmonary TB in South India. Frequency of the wild type genotype (CC), as well as of the mutant genotypes (CT or TT) in the IRIS and non-IRIS patients was estimated. Comparative analyses were performed between wild genotype (CC) and the mutant genotypes (CT or TT) and tested for association between the LTA4H polymorphisms and IRIS incidence and clinical severity. A total of 142 eligible ART-naïve patients were included in the analyses. Eighty-six individuals exhibited the wild genotype (CC) while 56 had mutant genotypes (43-CT and only 13-TT). Variant allele frequency was 0.23 and 0.26 in non-IRIS group and in IRIS group, respectively. Upon ART initiation, 51 patients developed IRIS while 91 did not. IRIS incidence was 34% and 37% in the wild (CC) and mutant type (CT/TT), respectively (p = 0.858) with a higher frequency of severe IRIS presentation in the mutant genotype group compared to the wild type genotype (p = 0.0006). A logistic regression model confirmed the association between the presence of CT/TT genotypes and occurrence of severe IRIS. Corticosteroid therapy successfully resolved IRIS in all cases irrespective of the LTA4H genotype. A higher incidence of severe IRIS among patients with mutant LTA4H genotypes (CT and TT) was observed compared to the wild type, despite similar IRIS incidence and immune restoration in both groups. Steroids were effective in alleviating IRIS in all the genotypes.
Model based Computerized Ionospheric Tomography in space and time
NASA Astrophysics Data System (ADS)
Tuna, Hakan; Arikan, Orhan; Arikan, Feza
2018-04-01
Reconstruction of the ionospheric electron density distribution in space and time not only provide basis for better understanding the physical nature of the ionosphere, but also provide improvements in various applications including HF communication. Recently developed IONOLAB-CIT technique provides physically admissible 3D model of the ionosphere by using both Slant Total Electron Content (STEC) measurements obtained from a GPS satellite - receiver network and IRI-Plas model. IONOLAB-CIT technique optimizes IRI-Plas model parameters in the region of interest such that the synthetic STEC computations obtained from the IRI-Plas model are in accordance with the actual STEC measurements. In this work, the IONOLAB-CIT technique is extended to provide reconstructions both in space and time. This extension exploits the temporal continuity of the ionosphere to provide more reliable reconstructions with a reduced computational load. The proposed 4D-IONOLAB-CIT technique is validated on real measurement data obtained from TNPGN-Active GPS receiver network in Turkey.
Letang, Emilio; Miró, José M.; Nhampossa, Tacilta; Ayala, Edgar; Gascon, Joaquim; Menéndez, Clara; Alonso, Pedro L.; Naniche, Denise
2011-01-01
Background There is limited data on the epidemiology of Immune Reconstitution Inflammatory Syndrome (IRIS) in rural sub-Saharan Africa. A prospective observational cohort study was conducted to assess the incidence, clinical characteristics, outcome and predictors of IRIS in rural Mozambique. Methods One hundred and thirty-six consecutive antiretroviral treatment (ART)-naïve HIV-1-infected patients initiating ART at the Manhiça district hospital were prospectively followed for development of IRIS over 16 months. Survival analysis by Cox regression was performed to identify pre-ART predictors of IRIS development. Results Thirty-six patients developed IRIS [26.5%, incidence rate 3.1 cases/100 persons-month of ART (95% CI 2.2–4.3)]. Median time to IRIS onset was 62 days from ART initiation (IQR 35.5–93.5). Twenty-five cases (69.4%) were “unmasking”, 10 (27.8%) were “paradoxical”, and 1 (2.8%) developed a paradoxical worsening followed by the unmasking of another condition. Systemic OI (OI-IRIS) accounted for 47% (17/36) of IRIS cases, predominantly of KS (8 cases) and TB (6 cases) IRIS. Mucocutaneous IRIS manifestations (MC-IRIS) accounted for 53% (19/36) of IRIS events, mostly tinea (9 cases) and herpes simplex infection (3 cases). Multivariate analysis identified two independent predictors of IRIS development: pre-ART CD4 count <50 cells/µl (HR 2.3, 95% CI 1.19–4.44, p = 0.01) and body mass index (BMI) <18.5 (HR 2.15, 95% CI 1.07–4.3, p = 0.03). The pre-cART proportion of activated T-cells, as well as the immunologic and virologic response to ART were not associated with IRIS development. All patients continued on ART, 7 (19.4%) required hospitalization and there were 3 deaths (8.3%) attributable to IRIS. Conclusions IRIS is common in patients initiating ART in rural Mozambique. Pre-ART CD4 counts and BMI can easily be assessed at ART initiation in rural sub-Saharan Africa to identify patients at high risk of IRIS, for whom close supervision is warranted. PMID:21386993
Schultz, Eliette; Cloeckaert, Axel; Doublet, Benoît; Madec, Jean-Yves; Haenni, Marisa
2017-01-01
Proteae, and especially Proteus mirabilis, are often the cause of urinary tract infections (UTIs) in humans. They were reported as carriers of extended-spectrum β-lactamase (ESBL) genes, and recently of carbapenemases, mostly carried by the Salmonella genomic island 1 (SGI1) and Proteus genomic island 1 (PGI1). Proteae have also lately become an increasing cause of UTIs in companion animals, but antimicrobial susceptibility data in animals are still scarce. Here, we report the characterization of 468 clinical epidemiologically unrelated Proteae strains from animals collected between 2013 and 2015 in France. Seventeen P. mirabilis strains (3.6%) were positive for SGI1/PGI1 and 18 Proteae (3.8%) were resistant to extended-spectrum cephalosporins (ESC). The 28 isolates carrying SGI1/PGI1 and/or ESC-resistance genes were isolated from cats, dogs, and horses. ESBL genes were detected in six genetically related P. mirabilis harboring blaV EB-6 on the SGI1-V variant, but also independently of the SGI1-V, in 3 P. mirabilis strains (blaVEB-6 and blaCTX-M-15) and 1 Providencia rettgeri strain (blaCTX-M-1). The AmpC resistance genes blaCMY -2 and/or blaDHA-16 were detected in 9 P. mirabilis strains. One strain presented both an ESBL and AmpC gene. Interestingly, the majority of the ESBL/AmpC resistance genes were located on the chromosome. In conclusion, multiple ESC-resistance genetic determinants are circulating in French animals, even though SGI1-V-carrying P. mirabilis seems to be mainly responsible for the spread of the ESBL gene blaVEB-6 in dogs and horses. These results are of public health relevance and show that companion animals in close contact with humans should be regarded as a potential reservoir of ESC-resistant bacteria as well as a reservoir of ESC-resistance genes that could further disseminate to human pathogens. PMID:28154560
Biochemical changes of salivary gland adenoid cystic carcinoma cells induced by SGI-1776
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, Xiuxiu, E-mail: show-1989@163.com; The First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325000; Yu, Yunfang, E-mail: yyf_8247425@163.com
Provirus integration site for Moloney murine leukemia virus 1 (Pim-1) has proved to be an oncogene and it is known that to depress Pim-1 activity may be a novel oncological treatment strategy. SGI-1776, a small molecule, is the first clinically tested inhibitor of the Pim kinase family. Here, we aimed to explore the effect of SGI-1776 on salivary adenoid cystic carcinoma (SACC). Expression of Pim-1 was confirmed in SACC and control tissues by qRT-PCR. After SGI-1776 treatment, the Pim-1 expressions and Pim-1 kinase activity in both SACC-83 and SACC-LM cell lines were measured. Cell proliferation, cell invasion, cell cycle, apoptosismore » and mitochondrial membrane potential were analyzed. Also, the expression of FOXO3a, p-FOXO3a, RUNX3, Bcl-2, BAD, p-BAD, Bim and p-Bim were detected by Western blot. The results showed that Pim-1 was significantly overexpressed in SACC tissues. SGI-1776 down-regulated the Pim-1 expression, inhibited Pim-1 kinase activity, reduced cell proliferation, decreased invasive ability, increased caspase-3 activity and induced apoptosis, cell cycle arrest and mitochondrial depolarization. Reduced expression was also seen in p-FOXO3a, RUNX3, Bcl-2, p-BAD and p-Bim, whereas no significant changes were observed from FOXO3a, BAD and Bim. These results confirm the pivotal role of Pim-1 in SACC and suggest that targeting Pim-1 kinase signal pathway by SGI-1776 might be a promising therapeutic modality for SACC.« less
Biochemical changes of salivary gland adenoid cystic carcinoma cells induced by SGI-1776.
Hou, Xiuxiu; Yu, Yunfang; Feng, Jianguo; Wang, Jiafeng; Zheng, Chuanming; Ling, Zhiqiang; Ge, Minghua; Zhu, Xin
2017-03-15
Provirus integration site for Moloney murine leukemia virus 1 (Pim-1) has proved to be an oncogene and it is known that to depress Pim-1 activity may be a novel oncological treatment strategy. SGI-1776, a small molecule, is the first clinically tested inhibitor of the Pim kinase family. Here, we aimed to explore the effect of SGI-1776 on salivary adenoid cystic carcinoma (SACC). Expression of Pim-1 was confirmed in SACC and control tissues by qRT-PCR. After SGI-1776 treatment, the Pim-1 expressions and Pim-1 kinase activity in both SACC-83 and SACC-LM cell lines were measured. Cell proliferation, cell invasion, cell cycle, apoptosis and mitochondrial membrane potential were analyzed. Also, the expression of FOXO3a, p-FOXO3a, RUNX3, Bcl-2, BAD, p-BAD, Bim and p-Bim were detected by Western blot. The results showed that Pim-1 was significantly overexpressed in SACC tissues. SGI-1776 down-regulated the Pim-1 expression, inhibited Pim-1 kinase activity, reduced cell proliferation, decreased invasive ability, increased caspase-3 activity and induced apoptosis, cell cycle arrest and mitochondrial depolarization. Reduced expression was also seen in p-FOXO3a, RUNX3, Bcl-2, p-BAD and p-Bim, whereas no significant changes were observed from FOXO3a, BAD and Bim. These results confirm the pivotal role of Pim-1 in SACC and suggest that targeting Pim-1 kinase signal pathway by SGI-1776 might be a promising therapeutic modality for SACC. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Khan, Faisal Aziz; Niazi, Shafaq Pervez Khan; Khan, Assad Zaman
2017-09-01
To determine the relationship of the van Herick angle grading system with the level of iris insertion and peripheral iris configuration. Observational study. Eye department, Combined Military Hospital, Malir Cantt., Karachi, from May to October 2015. Sixty-five eyes of 65 patients were recruited. Anterior chamber depth at the temporal limbus was measured as a fraction of corneal section thickness using van Herick technique and graded on the standard 4-point scale of the van Herick grading system. Gonioscopy of the temporal quadrant was performed with a Posner 4 mirror goniolens and both the true level of iris insertion and peripheral iris configuration were recorded on a 4-point scale so as to equate with the van Herick 4-point grading system. Spearman's rho test was applied to determine the relationship of the van Herick grading system with level of iris root insertion and peripheral iris configuration. Amoderate positive correlation between van Herick grade and peripheral iris configuration was found which was statistically significant (rs=0.42, p < 0.001). Astatistically significant and moderate positive correlation was also detected between van Herick grade and the level of iris insertion (rs=0.45, p < 0.001). The van Herick grade has a moderately positive relationship with the peripheral iris configuration and true level of iris insertion.
Jie, Li-ming; Wang, Qian; Zheng, Lin
2013-08-01
To assess the safety, efficacy, stability and changes in cylindrical degree and axis after real-time iris recognition guided LASIK with femtosecond laser flap creation for the correction of myopic astigmatism. Retrospective case series. This observational case study comprised 136 patients (249 eyes) with myopic astigmatism in a 6-month trial. Patients were divided into 3 groups according to the pre-operative cylindrical degree: Group 1, -0.75 to -1.25 D, 106 eyes;Group 2, -1.50 to -2.25 D, 89 eyes and Group 3, -2.50 to -5.00 D, 54 eyes. They were also grouped by pre-operative astigmatism axis:Group A, with the rule astigmatism (WTRA), 156 eyes; Group B, against the rule astigmatism (ATRA), 64 eyes;Group C, oblique axis astigmatism, 29 eyes. After femtosecond laser flap created, real-time iris recognized excimer ablation was performed. The naked visual acuity, the best-corrected visual acuity, the degree and axis of astigmatism were analyzed and compared at 1, 3 and 6 months postoperatively. Static iris recognition detected that eye cyclotorsional misalignment was 2.37° ± 2.16°, dynamic iris recognition detected that the intraoperative cyclotorsional misalignment range was 0-4.3°. Six months after operation, the naked visual acuity was 0.5 or better in 100% cases. No eye lost ≥ 1 line of best spectacle-corrected visual acuity (BSCVA). Six months after operation, the naked vision of 227 eyes surpassed the BSCVA, and 87 eyes gained 1 line of BSCVA. The degree of astigmatism decreased from (-1.72 ± 0.77) D (pre-operation) to (-0.29 ± 0.25) D (post-operation). Six months after operation, WTRA from 157 eyes (pre-operation) decreased to 43 eyes (post-operation), ATRA from 63 eyes (pre-operation) decreased to 28 eyes (post-operation), oblique astigmatism increased from 29 eyes to 34 eyes and 144 eyes became non-astigmatism. The real-time iris recognition guided LASIK with femtosecond laser flap creation can compensate deviation from eye cyclotorsion, decrease iatrogenic astigmatism, and provides more precise treatment for the degree and axis of astigmatism .It is an effective and safe procedure for the treatment of myopic astigmatism.
Bariatric surgery insurance requirements independently predict surgery dropout.
Love, Kaitlin M; Mehaffey, J Hunter; Safavian, Dana; Schirmer, Bruce; Malin, Steven K; Hallowell, Peter T; Kirby, Jennifer L
2017-05-01
Many insurance companies have considerable prebariatric surgery requirements despite a lack of evidence for improved clinical outcomes. The hypothesis of this study is that insurance-specific requirements will be associated with a decreased progression to surgery and increased delay in time to surgery. Retrospective data collection was performed for patients undergoing bariatric surgery evaluation from 2010-2015. Patients who underwent surgery (SGY; n = 827; mean body mass index [BMI] 49.1) were compared with those who did not (no-SGY; n = 648; mean BMI: 49.4). Univariate and multivariate analysis were performed to identify specific co-morbidity and insurance specific predictors of surgical dropout and time to surgery. A total of 1475 patients using 12 major insurance payors were included. Univariate analysis found insurance requirements associated with surgical drop out included longer median diet duration (no-SGY = 6 mo; SGY = 3 mo; P<.001); primary care physician letter of necessity (P<.0001); laboratory testing (P = .019); and evaluation by cardiology (P<.001), pulmonology (P<.0001), or psychiatry (P = .0003). Using logistic regression to control for co-morbidities, longer diet requirement (odds ratio [OR] .88, P<.0001), primary care physician letter (OR .33, P<.0001), cardiology evaluation (OR .22, P = .038), and advanced laboratory testing (OR 5.75, P = .019) independently predicted surgery dropout. Additionally, surgical patients had an average interval between initial visit and surgery of 5.8±4.6 months with significant weight gain (2.1 kg, P<.0001). Many prebariatric surgery insurance requirements were associated with lack of patient progression to surgery in this study. In addition, delays in surgery were associated with preoperative weight gain. Although prospective and multicenter studies are needed, these findings have major policy implications suggesting insurance requirements may need to be reconsidered to improve medical care. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Narendran, Gopalan; Kavitha, Dhanasekaran; Karunaianantham, Ramesh; Gil-Santana, Leonardo; Almeida-Junior, Jilson L.; Reddy, Sirasanambatti Devarajulu; Kumar, Marimuthu Makesh; Hemalatha, Haribabu; Jayanthi, Nagesh Nalini; Ravichandran, Narayanan; Krishnaraja, Raja; Prabhakar, Angamuthu; Manoharan, Tamizhselvan; Nithyananthan, Lokeswaran; Arjunan, Gunasundari; Natrajan, Mohan; Swaminathan, Soumya
2016-01-01
Background Paradoxical tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) is an inflammatory phenomenon complicating HIV management in coincidental tuberculosis (TB) infection, upon immune reconstitution driven by antiretroviral therapy (ART). Leukotriene A4 hydroxylase (LTA4H), an enzyme which converts LTA4 to LTB4, regulates the balance between the anti-inflammatory lipoxins and pro-inflammatory LTB4, with direct implications in TB-driven inflammation. In humans, a single nucleotide polymorphism (SNP) in the LTA4H promoter which regulates its transcriptional activity (rs17525495) has been identified and described to impact clinical severity of TB presentation and response to corticosteroid therapy. Notably, the role of LTA4H on TB-IRIS has not been previously evaluated. Here, we performed an exploratory investigation testing the association of LTA4H polymorphism with respect to frequency of TB-IRIS occurrence and severity of TB-IRIS presentation in HIV-TB co-infected individuals. Methods Genotypic evaluation of the LTA4H enzyme from available samples was retrospectively correlated with clinical data captured in case sheets including IRIS details. The cohort included patients recruited from a prospective cohort study nested within a randomized clinical trial (NCT0933790) of ART-naïve HIV+ patients with newly diagnosed rifampicin sensitive pulmonary TB in South India. Frequency of the wild type genotype (CC), as well as of the mutant genotypes (CT or TT) in the IRIS and non-IRIS patients was estimated. Comparative analyses were performed between wild genotype (CC) and the mutant genotypes (CT or TT) and tested for association between the LTA4H polymorphisms and IRIS incidence and clinical severity. Results A total of 142 eligible ART-naïve patients were included in the analyses. Eighty-six individuals exhibited the wild genotype (CC) while 56 had mutant genotypes (43-CT and only 13-TT). Variant allele frequency was 0.23 and 0.26 in non-IRIS group and in IRIS group, respectively. Upon ART initiation, 51 patients developed IRIS while 91 did not. IRIS incidence was 34% and 37% in the wild (CC) and mutant type (CT/TT), respectively (p = 0.858) with a higher frequency of severe IRIS presentation in the mutant genotype group compared to the wild type genotype (p = 0.0006). A logistic regression model confirmed the association between the presence of CT/TT genotypes and occurrence of severe IRIS. Corticosteroid therapy successfully resolved IRIS in all cases irrespective of the LTA4H genotype. Conclusion A higher incidence of severe IRIS among patients with mutant LTA4H genotypes (CT and TT) was observed compared to the wild type, despite similar IRIS incidence and immune restoration in both groups. Steroids were effective in alleviating IRIS in all the genotypes. PMID:27643598
NASA Astrophysics Data System (ADS)
Zhao, Huangxuan; Wang, Guangsong; Lin, Riqiang; Gong, Xiaojing; Song, Liang; Li, Tan; Wang, Wenjia; Zhang, Kunya; Qian, Xiuqing; Zhang, Haixia; Li, Lin; Liu, Zhicheng; Liu, Chengbo
2018-04-01
For the diagnosis and evaluation of ophthalmic diseases, imaging and quantitative characterization of vasculature in the iris are very important. The recently developed photoacoustic imaging, which is ultrasensitive in imaging endogenous hemoglobin molecules, provides a highly efficient label-free method for imaging blood vasculature in the iris. However, the development of advanced vascular quantification algorithms is still needed to enable accurate characterization of the underlying vasculature. We have developed a vascular information quantification algorithm by adopting a three-dimensional (3-D) Hessian matrix and applied for processing iris vasculature images obtained with a custom-built optical-resolution photoacoustic imaging system (OR-PAM). For the first time, we demonstrate in vivo 3-D vascular structures of a rat iris with a the label-free imaging method and also accurately extract quantitative vascular information, such as vessel diameter, vascular density, and vascular tortuosity. Our results indicate that the developed algorithm is capable of quantifying the vasculature in the 3-D photoacoustic images of the iris in-vivo, thus enhancing the diagnostic capability of the OR-PAM system for vascular-related ophthalmic diseases in vivo.
Integrated Risk Information System (IRIS)
d - Limonene ; CASRN 5989 - 27 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff
Combination of Pim kinase inhibitor, SGI-1776, with bendamustine in B-cell lymphoma
Yang, Qingshan; Chen, Lisa S; Neelapu, Sattva S.; Gandhi, Varsha
2013-01-01
SGI-1776 is a small molecule Pim kinase inhibitor that primarily targets c-Myc-driven transcription and cap-dependent translation in mantle cell lymphoma (MCL) cells. Bendamustine is an alkylating chemotherapeutic agent approved for use in B-cell lymphoma that is known to induce DNA damage and to initiate response to repair. We hypothesized that while each drug leads to the effects as stated above, combination of these drugs will enhance SGI-1776-induced inhibition of global transcription and translation processes, while promoting bendamustine-triggered decrease of DNA synthesis and DNA damage response in B-cell lymphoma. Both SGI-1776 and bendamustine as single agents effectively induced apoptosis and when used in combination, additive effect in cell killing was observed in MCL cell lines, JeKo-1 and Mino, as well as MCL and splenic marginal zone lymphoma (a type of B-cell lymphoma) primary cells. As expected, SGI-1776 was effective in inducing decrease of global RNA and protein synthesis, while bendamustine significantly inhibited DNA synthesis and generated DNA damage response. When used in combination, effects were intensified in DNA, RNA and protein syntheses compared to single agent treatments. Together, these data provided foundation and suggested feasibility of using Pim kinase inhibitor in combination with chemotherapeutic agents such as bendamustine in B-cell lymphoma. PMID:24290221
Schuster, Alexander K; Fischer, Joachim E; Vossmerbaeumer, Urs
2017-03-01
Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of <-4 or >+3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 subjects served as emmetropic group (-0.5 ≤ x ≤+0.5 dioptres). Previous ocular surgery was exclusion criterion. Six hundred and sixty-eight eyes of 398 persons [292 male (76%); age range; 18-66 years] were included in the study. In the myopic group, 105 eyes had a concave iris configuration (26%), while in the hyperopic group, no eye had this configuration (0%) and in the emmetropic group five eyes (5%). Convex iris configuration was found in 96% of hyperopic, in 85% of the emmetropic and in 67% of the myopic eyes. There was an association between concave iris configuration and myopia, younger age and male gender, and with anterior chamber angle width. Spectral domain OCT images can be used for analysis of the iris structure and geometry. Our results are limited to the properties of the study population having an age range from 18 to 66 years and consisting mainly of men. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Laganà, Antonio Simone; Barbaro, Luisa; Pizzo, Alfonsa
2015-05-01
To evaluate the effects of D-Chiro-Inositol in women affected by polycystic ovary syndrome (PCOS). We enrolled 48 patients, with homogeneous bio-physical characteristics, affected by PCOS and menstrual irregularities. These patients underwent treatment with 1 gr of D-Chiro-Inositol/die plus 400 mcg of Folic Acid/die orally for 6 months. We analyzed pre-treatment and post-treatment BMI, Systolic and Diastolic blood pressure, Ferriman-Gallwey score, Cremoncini score, serum LH, LH/FSH ratio, total and free testosterone, DHEA-S, Δ-4-androstenedione, SHBG, prolactin, glucose/IRI ratio, HOMA index, and resumption of regular menstrual cycles. We evidenced a statistically significant reduction of systolic blood pressure, Ferriman-Gallwey score, LH, LH/FSH ratio, total Testosterone, free Testosterone, ∆-4-Androstenedione, Prolactin, and HOMA Index; in the same patients, we noticed a statistically significant increase of SHBG and Glycemia/IRI ratio. Moreover, we observed statistically significant (62.5%; p < 0.05) post-treatment menstrual cycle regularization. D-Chiro-Inositol is effective in improving ovarian function and metabolism of patients affected by PCOS.
4D computerized ionospheric tomography by using GPS measurements and IRI-Plas model
NASA Astrophysics Data System (ADS)
Tuna, Hakan; Arikan, Feza; Arikan, Orhan
2016-07-01
Ionospheric imaging is an important subject in ionospheric studies. GPS based TEC measurements provide very accurate information about the electron density values in the ionosphere. However, since the measurements are generally very sparse and non-uniformly distributed, computation of 3D electron density estimation from measurements alone is an ill-defined problem. Model based 3D electron density estimations provide physically feasible distributions. However, they are not generally compliant with the TEC measurements obtained from GPS receivers. In this study, GPS based TEC measurements and an ionosphere model known as International Reference Ionosphere Extended to Plasmasphere (IRI-Plas) are employed together in order to obtain a physically accurate 3D electron density distribution which is compliant with the real measurements obtained from a GPS satellite - receiver network. Ionospheric parameters input to the IRI-Plas model are perturbed in the region of interest by using parametric perturbation models such that the synthetic TEC measurements calculated from the resultant 3D electron density distribution fit to the real TEC measurements. The problem is considered as an optimization problem where the optimization parameters are the parameters of the parametric perturbation models. Proposed technique is applied over Turkey, on both calm and storm days of the ionosphere. Results show that the proposed technique produces 3D electron density distributions which are compliant with IRI-Plas model, GPS TEC measurements and ionosonde measurements. The effect of the GPS receiver station number on the performance of the proposed technique is investigated. Results showed that 7 GPS receiver stations in a region as large as Turkey is sufficient for both calm and storm days of the ionosphere. Since the ionization levels in the ionosphere are highly correlated in time, the proposed technique is extended to the time domain by applying Kalman based tracking and smoothing approaches onto the obtained results. Combining Kalman methods with the proposed 3D CIT technique creates a robust 4D ionospheric electron density estimation model, and has the advantage of decreasing the computational cost of the proposed method. Results applied on both calm and storm days of the ionosphere show that, new technique produces more robust solutions especially when the number of GPS receiver stations in the region is small. This study is supported by TUBITAK 114E541, 115E915 and Joint TUBITAK 114E092 and AS CR 14/001 projects.
Reichetzeder, Christoph; von Websky, Karoline; Tsuprykov, Oleg; Mohagheghi Samarin, Azadeh; Falke, Luise Gabriele; Dwi Putra, Sulistyo Emantoko; Hasan, Ahmed Abdallah; Antonenko, Viktoriia; Curato, Caterina; Rippmann, Jörg; Klein, Thomas; Hocher, Berthold
2017-07-01
Results regarding protective effects of dipeptidyl peptidase 4 (DPP4) inhibitors in renal ischaemia-reperfusion injury (IRI) are conflicting. Here we have compared structurally unrelated DPP4 inhibitors in a model of renal IRI. IRI was induced in uninephrectomized male rats by renal artery clamping for 30 min. The sham group was uninephrectomized but not subjected to IRI. DPP4 inhibitors or vehicle were given p.o. once daily on three consecutive days prior to IRI: linagliptin (1.5 mg·kg -1 ·day -1 ), vildagliptin (8 mg·kg -1 ·day -1 ) and sitagliptin (30 mg·kg -1 ·day -1 ). An additional group received sitagliptin until study end (before IRI: 30 mg·kg -1 ·day -1 ; after IRI: 15 mg·kg -1 ·day -1 ). Plasma-active glucagon-like peptide type 1 (GLP-1) increased threefold to fourfold in all DPP4 inhibitor groups 24 h after IRI. Plasma cystatin C, a marker of GFR, peaked 48 h after IRI. Compared with the placebo group, DPP4 inhibition did not reduce increased plasma cystatin C levels. DPP4 inhibitors ameliorated histopathologically assessed tubular damage with varying degrees of drug-specific efficacies. Renal osteopontin expression was uniformly reduced by all DPP4 inhibitors. IRI-related increased renal cytokine expression was not decreased by DPP4 inhibition. Renal DPP4 activity at study end was significantly inhibited in the linagliptin group, but only numerically reduced in the prolonged/dose-adjusted sitagliptin group. Active GLP-1 plasma levels at study end were increased only in the prolonged/dose-adjusted sitagliptin treatment group. In rats with renal IRI, DPP4 inhibition did not alter plasma cystatin C, a marker of glomerular function, but may protect against tubular damage. © 2017 The Authors. British Journal of Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.
A benzil and isoflavone from Iris tenuifolia.
Choudhary, Muhammad Iqbal; Hareem, Sumaira; Siddiqui, Hina; Anjum, Shazia; Ali, Shamsher; Atta-Ur-Rahman; Zaidi, Mudassir Israr
2008-06-01
Two compounds, tenuifodione (1) and tenuifone (2), and 12 known compounds, izalpinin (3), alpinone (4), arborinone (5), irilin B (6), irisone A (7), irisone B (8), betavulgarin (9), beta-sitosterol (10), 5,7-dihydroxy-2',6-dimethoxyisoflavone (11), 2',5-dihdroxy-6,7-methylenedioxy flavanone (12), irisoid A (13) and ethyl-beta-d-glucopyranoside (14) were isolated from the whole plant of Iris tenuifolia Pall. All compounds, except 12, were isolated for the first time from this plant. Compounds 2, 3 and 11 have shown a considerable DPPH radical scavenging activity. Structures of these compounds were identified on the basis of spectroscopic techniques, including 2D NMR. Compounds 3, 5 and 7 were also subjected to single-crystal X-ray diffraction analysis and their structures were unambiguously deduced.
IRIS Toxicological Review of Ammonia Noncancer Inhalation (Interagency Science Discussion Draft)
In September 2016, EPA finalized the IRIS assessment of Ammonia (Noncancer Inhalation). The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release in June 2016. Consistent with the May 2009 IRIS assessment d...
4-(2,4-Dichlorophenoxy)butyric acid (2,4-DB)
Integrated Risk Information System (IRIS)
Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) 4 - ( 2,4 - Dichloro
4-(2-Methyl-4-chlorophenoxy) butyric acid (MCPB)
Integrated Risk Information System (IRIS)
Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment This IRIS Summary has been removed from the IRIS database and is available for historical reference purposes . ( July 2016 ) 4 - ( 2 - Methyl - 4
Idaho National Laboratory - Brent Stacey, John Grossenbacher, Shane Johnson
2017-12-09
ICE STORM is a super computer procured by INL from a well-knowncomputer vendor, SGI. ICE STORM is rated as No. 64 on the list of ICE STORM is a super computer procured by INL from a well-knowncomputer vendor, SGI. ICE STORM is rated as No. 64 on the lis
Adam, Madeleine K; Jarrett-Wilkins, Charles; Beards, Michael; Staykov, Emiliyan; MacFarlane, Liam R; Bell, Toby D M; Matthews, Jacqueline M; Manners, Ian; Faul, Charl F J; Moens, Pierre D J; Ben, Robert N; Wilkinson, Brendan L
2018-06-04
Antifreeze glycoproteins (AFGPs) are polymeric natural products that have drawn considerable interest in diverse research fields owing to their potent ice recrystallization inhibition (IRI) activity. Self-assembled materials have emerged as a promising class of biomimetic ice growth inhibitor, yet the development of AFGP-based supramolecular materials that emulate the aggregative behavior of AFGPs have not yet been reported. This work reports the first example of the 1D self-assembly and IRI activity of AFGP-functionalized perylene bisimides (AFGP-PBIs). Glycopeptide-functionalized PBIs underwent 1D self-assembly in water and showed modest IRI activity, which could be tuned through substitution of the PBI core. This work presents essential proof-of-principle for the development of novel IRIs as potential supramolecular cryoprotectants and glycoprotein mimics. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Contrasting cellular damage after Blue-IRIS and Femto-LASIK in cat cornea.
Wozniak, Kaitlin T; Elkins, Noah; Brooks, Daniel R; Savage, Daniel E; MacRae, Scott; Ellis, Jonathan D; Knox, Wayne H; Huxlin, Krystel R
2017-12-01
Blue-intra-tissue refractive index shaping (Blue-IRIS) is a new approach to laser refractive correction of optical aberrations in the eye, which alters the refractive index of the cornea rather than changing its shape. Before it can be implemented in humans, it is critical to establish whether and to what extent, Blue-IRIS damages the cornea. Here, we contrasted the impact of -1.5 D cylinder refractive corrections inscribed using either Blue-IRIS or femtosecond laser in-situ keratomileusis (femto-LASIK) on corneal cell viability. Blue-IRIS was used to write a -1.5 D cylinder gradient index (GRIN) lens over a 2.5 mm by 2.5 mm area into the mid-stromal region of the cornea in six freshly-enucleated feline eyes. The same correction (-1.5 D cylinder) was inscribed into another four cat eyes using femto-LASIK. Six hours later, all corneas were processed for histology and stained for terminal deoxynucleotidyl transferase-mediated dUTP-digoxigenin nick end labeling (TUNEL) and p-γ-H2AX to label damaged cells. In Blue-IRIS-treated corneas, no tissue was removed and TUNEL-stained cells were confined to the laser focal zone in the stroma. In femto-LASIK, photoablation removed 14 μm of anterior stroma, but in addition, TUNEL-positive cells clustered across the femto-flap, the epithelium at the flap edges and the stroma below the ablation zone. Keratocytes positive for p-γ-H2AX were seen adjacent to all Blue-IRIS focal zones, but were completely absent from femto-LASIK-treated corneas. Unlike femto-LASIK, Blue-IRIS attains refractive correction in the cornea without tissue removal and only causes minimal, localized keratocyte death within the laser focal zones. In addition, Blue-IRIS induced DNA modifications associated with phosphorylation of γ-H2AX in keratocytes adjacent to the laser focal zones. We posit that this p-γ-H2AX response is related to alterations in chromatin structure caused by localized changes in osmolarity, a possible mechanism for the induced refractive index changes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Day, Yuan-Ji; Huang, Liping; Ye, Hong; Li, Li; Linden, Joel; Okusa, Mark D
2006-03-01
A(2A) adenosine receptor (A(2A)R)-expressing bone marrow (BM)-derived cells contribute to the renal protective effect of A(2A) agonists in renal ischemia-reperfusion injury (IRI). We performed IRI in mice lacking T and B cells to determine whether A(2A)R expressed in CD4+ cells mediate protection from IRI. Rag-1 knockout (KO) mice were protected in comparison to wild-type (WT) mice when subjected to IRI. ATL146e, a selective A(2A) agonist, did not confer additional protection. IFN-gamma is an important early signal in IRI and is thought to contribute to reperfusion injury. Because IFN-gamma is produced by kidney cells and T cells we performed IRI in BM chimeras in which the BM of WT mice was reconstituted with BM from IFN-gamma KO mice (IFN-gamma KO-->WT chimera). We observed marked reduction in IRI in comparison to WT-->WT chimeras providing additional indirect support for the role of T cells. To confirm the role of CD4+ A(2A)R in mediating protection from IRI, Rag-1 KO mice were subjected to ischemia-reperfusion. The protection observed in Rag-1 KO mice was reversed in Rag-1 KO mice that were adoptively transferred WT CD4+ cells (WT CD4+-->Rag-1 KO) or A(2A) KO CD4+ cells (A(2A) KO CD4+-->Rag-1 KO). ATL146e reduced injury in WT CD4+-->Rag-1 KO mice but not in A(2A) KO CD4+-->Rag-1 KO mice. Rag-1 KO mice reconstituted with CD4+ cells derived from IFN-gamma KO mice (IFN-gamma CD4+-->Rag-1 KO) were protected from IRI; ATL146e conferred no additional protection. These studies demonstrate that CD4+ IFN-gamma contributes to IRI and that A(2A) agonists mediate protection from IRI through action on CD4+ cells.
Combination of Pim kinase inhibitor SGI-1776 and bendamustine in B-cell lymphoma.
Yang, Qingshan; Chen, Lisa S; Neelapu, Sattva S; Gandhi, Varsha
2013-09-01
SGI-1776 is a small-molecule Pim kinase inhibitor that primarily targets c-MYC-driven transcription and cap-dependent translation in mantle cell lymphoma (MCL) cells. Bendamustine is an alkylating chemotherapeutic agent approved for use in B-cell lymphoma that is known to induce DNA damage and initiate response to repair. Our studies were conducted in MCL cell lines JeKo-1 and Mino, as well as primary B-cell lymphoma samples of MCL and splenic marginal zone lymphoma (SMZL), where we treated cells with SGI-1776 and bendamustine. We measured levels of cellular apoptosis, macromolecule synthesis inhibition, and DNA damage induced by drug treatments. Both SGI-1776 and bendamustine effectively induced apoptosis as single agents, and when used in combination, an additive effect in cell killing was observed in MCL cell lines JeKo-1 and Mino, as well as in MCL and SMZL primary cells. As expected, SGI-1776 was effective in inducing a decrease of global RNA and protein synthesis, and bendamustine significantly inhibited DNA synthesis and generated a DNA damage response. When used in combination, the effects were intensified in DNA, RNA, and protein synthesis inhibition compared with single-agent treatments. These data provide a foundation and suggest the feasibility of using Pim kinase inhibitors in combination with chemotherapeutic agents such as bendamustine in B-cell lymphoma. Copyright © 2013 Elsevier Inc. All rights reserved.
Watson, M J; Ke, B; Shen, X-D; Gao, F; Busuttil, R W; Kupiec-Weglinski, J W; Farmer, D G
2008-12-01
Ischemia/reperfusion injury (IRI) is a major problem in intestinal transplantation. Toll-like receptor 4 (TLR4) has been implicated as a possible link between the innate and adaptive immune systems, however little data exists regarding TLR4 in intestinal IRI. The goal of this study is to evaluate the involvement of TLR4 in intestinal IRI and to assess the effect on T cell related chemokine programs. C57BL6 mice underwent 100 minutes of warm intestinal ischemia by SMA clamping. Control WT mice underwent laparotomy without vascular occlusion. Separate survival and analysis groups were performed, and intestinal tissue was harvested at 1 hour, 2 hours, 4 hours, and 24 hours post-reperfusion. Analysis included histology, CD3 immunostaining, myeloperoxidase activity, Western blot, and PCR. Survival was significantly worse in the IRI group vs control (50% vs. 100%). IRI caused severe histopathological injury including mucosal erosions and villous congestion and hemorrhage. Myeloperoxidase activity increased in a time-dependent manner after IRI (2.71 0.25 at 1 hour, 2.92 0.25 at 2 hours, 4 0.16 at 4 hours, 5.1 0.25 at 24 hours vs 0.47 0.11 controls, P < .05). Protein expression of TLR4 followed by NF-kappaB was increased after IRI. Additionally, mRNA production of IP-10, MIP-2, MCP-1, and RANTES was increased at all time-points, as was mRNA for ICAM-1 and E-selectin. This study is the first to demonstrate increased expression of TLR4 and NF-kappaB after warm intestinal IRI. This detrimental cascade may be initiated by TLR4 via NF-kappaB signaling pathways, implicating TLR4 as a potential therapeutic target for the prevention of intestinal IRI.
Classroom Groups in Theory and Practice.
ERIC Educational Resources Information Center
Boydell, Deanne
1979-01-01
This article examines some British classroom studies and raises further research questions on small group instruction (SGI) as a teaching tool. Considered are teachers' use of SGI; its efficacy for cognitive, language, and social development; and student-to-student interaction patterns in relation to seating, sex, and ability mix. (SJL)
NASA Astrophysics Data System (ADS)
Madhavi Latha, T.; Peddi Naidu, P.; Madhusudhana Rao, D. N.; Indira Devi, M.
2012-11-01
Electron density profiles for the International Reference Ionosphere (IRI) 2001 and 2007 models have been utilized in evaluating the D-region conductivity parameter in earth ionosphere wave guide calculations. The day to night shift in reflection height of very low frequency (VLF) waves has been calculated using D-region conductivities derived from IRI models and the results are compared with those obtained from phase variation measurements of VLF transmissions from Rugby (England) made at Visakhapatnam (India). The values derived from the models are found to be much lower than those obtained from the experimental measurements. The values derived from the IRI models are in good agreement with those obtained from exponential conductivity model.
Haridas, V.; Pean, P.; Jasenosky, L.D.; Madec, Y.; Laureillard, D.; Sok, T.; Sath, S.; Borand, L.; Marcy, O.; Chan, S.; Tsitsikov, E.; Delfraissy, J.-F.; Blanc, F.-X.; Goldfeld, A.E.
2015-01-01
Objective To investigate the impact of tuberculosis (TB)-associated immune reconstitution syndrome (IRIS) upon immunological recovery and the T cell compartment after initiation of TB and antiretroviral therapy (ART). Design and methods We prospectively evaluated T cell immunophenotypes by flow cytometry and cytokines by Luminex assays in a subset (n=154) of highly immunosuppressed HIV+ patients with TB from the CAMELIA randomized clinical trial. We compared findings from patients who developed TB-IRIS to findings from patients who did not develop TB-IRIS. Data were evaluated with mixed effect linear regression, Kaplan-Meier estimates, and Wilcoxon rank sum tests, and q-values were calculated to control for multiple comparisons. Results Development of TB-IRIS was associated with significantly greater pre-ART frequencies of HLA-DR+CD45RO+CD4+, CCR5+CD4+, OX40+CD4+, and Fas+ effector memory (EM) CD8+ T cells, and significantly elevated levels of plasma IL-6, IL-1β, IL-8, and IL-10 and viral load. Post-ART initiation, EM CD4+ and Fas+ EM CD4+ T cell frequencies significantly expanded, and central memory (CM) CD4+ T cell frequencies significantly contracted in patients who experienced TB-IRIS. By week 34 post-TB treatment initiation, EM/CM CD4+ T cell ratios were markedly higher in TB-IRIS versus non-TB-IRIS patients. Conclusions A distinct pattern of pre-ART T cell and cytokine markers appear to poise the immune response to develop TB-IRIS. Experience of TB-IRIS is then associated with long-term remodeling of the CD4+ T cell memory compartment towards an EM-dominated phenotype. We speculate that these pre- and post-ART TB-IRIS-associated immune parameters may contribute to superior immune control of TB/HIV co-infection and better clinical outcome. PMID:25486415
IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...
Trichloroacetic acid is a crystalline solid with sharp, pungent odor. It is used as a soil sterilizer; and as a laboratory intermediate or reagent in the synthesis of a variety of medicinal products and organic chemicals. Trichloroacetic acid is also used industrially as an etching and pickling agent for the surface treatment of metals and as a solvent in the plastics industry. Trichloroacetic acid can be formed as a combustion byproduct of organic compounds in the presence of chlorine. It is also formed as a disinfection byproduct during water chlorination. The existing IRIS entry was added to the IRIS data base between 1994 and 1996. No RfD was developed. The IRIS program is updating the IRIS assessment for Trichloroacetic Acid. This update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for Trichloroacetic Acid will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference value for noncancer effects of Trichloroacetic Acid (RfD) and a cancer assessment. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency review and external scientific peer review. The final products will constitute the Agency's opinion on the
IRIS Toxicological Review of 1,4-Dioxane (with Inhalation ...
On September 9, 2011, the Toxicological Review of 1,4-Dioxane (inhalation) (External Review Draft) was posted for external peer review and public comment. Subsequently, the Toxicological Review and IRIS Summary were reviewed internally by EPA and by other federal agencies and Executive Office of the President before final public release. Based on the 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and the Executive Office of the President will be made publicly available. Accordingly, interagency comments with EPA's response and the interagency science discussion draft of the IRIS Toxicological Review of 1,4-dioxane (with inhalation update) and the draft IRIS Summary are posted on this site. The Toxicological Review of 1,4-dioxane provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to 1,4-dioxane.
TDIGG - TWO-DIMENSIONAL, INTERACTIVE GRID GENERATION CODE
NASA Technical Reports Server (NTRS)
Vu, B. T.
1994-01-01
TDIGG is a fast and versatile program for generating two-dimensional computational grids for use with finite-difference flow-solvers. Both algebraic and elliptic grid generation systems are included. The method for grid generation by algebraic transformation is based on an interpolation algorithm and the elliptic grid generation is established by solving the partial differential equation (PDE). Non-uniform grid distributions are carried out using a hyperbolic tangent stretching function. For algebraic grid systems, interpolations in one direction (univariate) and two directions (bivariate) are considered. These interpolations are associated with linear or cubic Lagrangian/Hermite/Bezier polynomial functions. The algebraic grids can subsequently be smoothed using an elliptic solver. For elliptic grid systems, the PDE can be in the form of Laplace (zero forcing function) or Poisson. The forcing functions in the Poisson equation come from the boundary or the entire domain of the initial algebraic grids. A graphics interface procedure using the Silicon Graphics (GL) Library is included to allow users to visualize the grid variations at each iteration. This will allow users to interactively modify the grid to match their applications. TDIGG is written in FORTRAN 77 for Silicon Graphics IRIS series computers running IRIX. This package requires either MIT's X Window System, Version 11 Revision 4 or SGI (Motif) Window System. A sample executable is provided on the distribution medium. It requires 148K of RAM for execution. The standard distribution medium is a .25 inch streaming magnetic IRIX tape cartridge in UNIX tar format. This program was developed in 1992.
Parallel Implementation of the Discontinuous Galerkin Method
NASA Technical Reports Server (NTRS)
Baggag, Abdalkader; Atkins, Harold; Keyes, David
1999-01-01
This paper describes a parallel implementation of the discontinuous Galerkin method. Discontinuous Galerkin is a spatially compact method that retains its accuracy and robustness on non-smooth unstructured grids and is well suited for time dependent simulations. Several parallelization approaches are studied and evaluated. The most natural and symmetric of the approaches has been implemented in all object-oriented code used to simulate aeroacoustic scattering. The parallel implementation is MPI-based and has been tested on various parallel platforms such as the SGI Origin, IBM SP2, and clusters of SGI and Sun workstations. The scalability results presented for the SGI Origin show slightly superlinear speedup on a fixed-size problem due to cache effects.
Iris Transponder-Communications and Navigation for Deep Space
NASA Technical Reports Server (NTRS)
Duncan, Courtney B.; Smith, Amy E.; Aguirre, Fernando H.
2014-01-01
The Jet Propulsion Laboratory has developed the Iris CubeSat compatible deep space transponder for INSPIRE, the first CubeSat to deep space. Iris is 0.4 U, 0.4 kg, consumes 12.8 W, and interoperates with NASA's Deep Space Network (DSN) on X-Band frequencies (7.2 GHz uplink, 8.4 GHz downlink) for command, telemetry, and navigation. This talk discusses the Iris for INSPIRE, it's features and requirements; future developments and improvements underway; deep space and proximity operations applications for Iris; high rate earth orbit variants; and ground requirements, such as are implemented in the DSN, for deep space operations.
Mizzi, Anna; Cozzi, Silvano; Beretta, Luigi; Greco, Massimiliano; Braga, Marco
2017-05-01
Pulmonary misplacement during the blind insertion of enteral feeding tubes is frequent, particularly in ventilated and neurologically impaired patients. This is probably the first clinical study using the Kangaroo Feeding Tube with IRIS technology (IRIS) which incorporates a camera designed to provide anatomic landmark visualization during insertion. The study aim was to evaluate IRIS performance during bedside gastric placement. This is the first prospective study to collect data on the use of IRIS. Twenty consecutive unconscious patients requiring enteral nutrition were recruited at a single center. IRIS placement was considered complete when a clear image of the gastric mucosa appeared. Correct placement was confirmed using a contrast-enhanced abdominal X-ray. To evaluate the device performance over time, the camera was activated every other day up to 17 d postplacement. In 7 (35%) patients, the trachea was initially visualized, requiring a second placement attempt with the same tube. The IRIS camera allowed recognition of the gastric mucosa in 18 (90%) patients. The esophagogastric junction was identified in one patient, while in a second patient the quality of visualization was poor. Contrast-enhanced X-ray confirmed the gastric placement of IRIS in all patients. IRIS allowed identification of gastric mucosa in 14 (70%) patients 3 d after placement. Performance progressively declined with time (P = 0.006, chi-square for trend). IRIS placement could have spared X-ray confirmation in almost all patients and prevented misplacement into the airway in about one third. Visualization quality needs to be improved, particularly after the first week. Copyright © 2016 Elsevier Inc. All rights reserved.
1999-01-01
roa.es C. Tomis RedIRIS, Centro Comunicaciones CSIC RedIRIS Serrano 142, 28006 Madrid, Spain tel + 34-91-585-5150 fax +34-91-564-7421 e-mail...I&D) and managed by the Centro de Comunicaciones CSIC RedIRIS, which depends on the Scientific Research Council (Consejo Superior de Investigaciones
Predicting Story Goodness Performance from Cognitive Measures Following Traumatic Brain Injury
ERIC Educational Resources Information Center
Le, Karen; Coelho, Carl; Mozeiko, Jennifer; Krueger, Frank; Grafman, Jordan
2012-01-01
Purpose: This study examined the prediction of performance on measures of the Story Goodness Index (SGI; Le, Coelho, Mozeiko, & Grafman, 2011) from executive function (EF) and memory measures following traumatic brain injury (TBI). It was hypothesized that EF and memory measures would significantly predict SGI outcomes. Method: One hundred…
Shen, Elizabeth P; Chen, Wei-Li; Hu, Fung-Rong
2010-03-01
To compare the efficacy and safety of manual limbal markings and wavefront-guided treatment with iris-registration software in laser in situ keratomileusis (LASIK) for myopic astigmatism. National Taiwan University Hospital, Taipei, Taiwan. Eyes with myopic astigmatism had LASIK with a Technolas 217z laser. Eyes in the limbal-marking group had conventional LASIK (PlanoScan or Zyoptix tissue-saving algorithm) with manual cyclotorsional-error adjustments according to 2 limbal marks. Eyes in the iris-registration group had wavefront-guided ablation (Zyoptix) in which cyclotorsional errors were automatically detected and adjusted. Refraction, corneal topography, and visual acuity data were compared between groups. Vector analysis was by the Alpins method. The mean preoperative spherical equivalent (SE) was -6.64 diopters (D) +/- 1.99 (SD) in the limbal-marking group and -6.72 +/- 1.86 D in the iris-registration group (P = .92). At 6 months, the mean SE was -0.42 +/- 0.63 D and -0.47 +/- 0.62 D, respectively (P = .08). There was no statistically significant difference between groups in the astigmatism correction, success, or flattening index values using 6-month postoperative refractive data. The angle of error was within +/-10 degrees in 73% of eyes in the limbal-marking group and 75% of eyes in the iris-registration group. Manual limbal markings and iris-registration software were equally effective and safe in LASIK for myopic astigmatism, showing that checking cyclotorsion by manual limbal markings is a safe alternative when automated systems are not available. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Immunomodulatory action of SGI-110, a hypomethylating agent, in acute myeloid leukemia cells
Srivastava, Pragya; Paluch, Benjamin E.; Matsuzaki, Junko; James, Smitha R.; Collamat-Lai, Golda; Karbach, Julia; Nemeth, Michael J.; Taverna, Pietro; Karpf, Adam R.; Griffiths, Elizabeth A.
2017-01-01
The mechanism of clinical action for the FDA approved hypomethylating drugs azacitidine and decitabine remains unresolved and in this context the potential immunomodulatory effect of these agents on leukemic cells is an area of active investigation. Induced expression of methylated Cancer Testis Antigen (CTA) genes has been demonstrated in leukemic cell lines following exposure to hypomethylating drugs in vitro. SGI-110 is a novel hypomethylating dinucleotide with prolonged in vivo exposure and clinical activity in patients with MDS and AML. We demonstrate that this agent, like decitabine, produces robust re-expression of the CTAs NY-ESO-1 and MAGE-A, both in vitro and in leukemia-bearing AML xenografts. Upregulation of these genes in vitro was sufficient to induce cytotoxicity by HLA-compatible CD8+ T-cells specific for NY-ESO-1, a well-recognized and immunogenic CTA. Additionally, exposure to SGI-110 enhances MHC class I and co-stimulatory molecule expression, potentially contributing to recognition of CTAs. SGI-110, like the parent compound decitabine, induces expression of CTAs and might modulate immune recognition of myeloid malignancy. PMID:25260825
Vatsa, Mayank; Singh, Richa; Noore, Afzel
2008-08-01
This paper proposes algorithms for iris segmentation, quality enhancement, match score fusion, and indexing to improve both the accuracy and the speed of iris recognition. A curve evolution approach is proposed to effectively segment a nonideal iris image using the modified Mumford-Shah functional. Different enhancement algorithms are concurrently applied on the segmented iris image to produce multiple enhanced versions of the iris image. A support-vector-machine-based learning algorithm selects locally enhanced regions from each globally enhanced image and combines these good-quality regions to create a single high-quality iris image. Two distinct features are extracted from the high-quality iris image. The global textural feature is extracted using the 1-D log polar Gabor transform, and the local topological feature is extracted using Euler numbers. An intelligent fusion algorithm combines the textural and topological matching scores to further improve the iris recognition performance and reduce the false rejection rate, whereas an indexing algorithm enables fast and accurate iris identification. The verification and identification performance of the proposed algorithms is validated and compared with other algorithms using the CASIA Version 3, ICE 2005, and UBIRIS iris databases.
Kolachala, Vasantha L.; Jiang, Rong; Abramowsky, Carlos; Shenoi, Asha; Kosters, Astrid; Pavuluri, Haritha; Anania, Frank; Kirk, Allan D.
2014-01-01
Ischemia-reperfusion injury (IRI) is a common clinical consequence of hepatic surgery, cardiogenic shock, and liver transplantation. A steatotic liver is particularly vulnerable to IRI, responding with extensive hepatocellular injury. Autophagy, a lysosomal pathway balancing cell survival and cell death, is engaged in IRI, although its role in IRI of a steatotic liver is unclear. The role of autophagy was investigated in high-fat diet (HFD)-fed mice exposed to IRI in vivo and in steatotic hepatocytes exposed to hypoxic IRI (HIRI) in vitro. Two inhibitors of autophagy, 3-methyladenine and bafilomycin A1, protected the steatotic hepatocytes from HIRI. Exendin 4 (Ex4), a glucagon-like peptide 1 analog, also led to suppression of autophagy, as evidenced by decreased autophagy-associated proteins [microtubule-associated protein 1A/1B-light chain 3 (LC3) II, p62, high-mobility group protein B1, beclin-1, and autophagy-related protein 7], reduced hepatocellular damage, and improved mitochondrial structure and function in HFD-fed mice exposed to IRI. Decreased autophagy was further demonstrated by reversal of a punctate pattern of LC3 and decreased autophagic flux after IRI in HFD-fed mice. Under the same conditions, the effects of Ex4 were reversed by the competitive antagonist exendin 9-39. The present study suggests that, in IRI of hepatic steatosis, treatment of hepatocytes with Ex4 mitigates autophagy, ameliorates hepatocellular injury, and preserves mitochondrial integrity. These data suggest that therapies targeting autophagy, by Ex4 treatment in particular, may ameliorate the effects of IRI in highly prevalent steatotic liver. PMID:25258410
Fluid and structure coupling analysis of the interaction between aqueous humor and iris.
Wang, Wenjia; Qian, Xiuqing; Song, Hongfang; Zhang, Mindi; Liu, Zhicheng
2016-12-28
Glaucoma is the primary cause of irreversible blindness worldwide associated with high intraocular pressure (IOP). Elevated intraocular pressure will affect the normal aqueous humor outflow, resulting in deformation of iris. However, the deformation ability of iris is closely related to its material properties. Meanwhile, the passive deformation of the iris aggravates the pupillary block and angle closure. The nature of the interaction mechanism of iris deformation and aqueous humor fluid flow has not been fully understood and has been somewhat a controversial issue. The purpose here was to study the effect of IOP, localization, and temperature on the flow of the aqueous humor and the deformation of iris interacted by aqueous humor fluid flow. Based on mechanisms of aqueous physiology and fluid dynamics, 3D model of anterior chamber (AC) was constructed with the human anatomical parameters as a reference. A 3D idealized standard geometry of anterior segment of human eye was performed. Enlarge the size of the idealization geometry model 5 times to create a simulation device by using 3D printing technology. In this paper, particle image velocimetry technology is applied to measure the characteristic of fluid outflow in different inlet velocity based on the device. Numerically calculations were made by using ANSYS 14.0 Finite Element Analysis. Compare of the velocity distributions to confirm the validity of the model. The fluid structure interaction (FSI) analysis was carried out in the valid geometry model to study the aqueous flow and iris change. In this paper, the validity of the model is verified through computation and comparison. The results indicated that changes of gravity direction of model significantly affected the fluid dynamics parameters and the temperature distribution in anterior chamber. Increased pressure and the vertical position increase the velocity of the aqueous humor fluid flow, with the value increased of 0.015 and 0.035 mm/s. The results act on the iris showed that, gravity direction from horizontal to vertical decrease the equivalent stress in the normal IOP model, while almost invariably in the high IOP model. With the increased of the iris elasticity modulus, the equivalent strain and the total deformation of iris is decreased. The maximal value of equivalent strain of iris in high IOP model is higher than that of in normal IOP model. The maximum deformation of iris is lower in the high IOP model than in the normal IOP model. The valid model of idealization geometry of human eye could be helpful to study the relationship between localization, iris deformation and IOP. So far the FSI analysis was carried out in that idealization geometry model of anterior segment to study aqueous flow and iris change.
SSM/OOM - SSM WITH OOM MANIPULATION CODE
NASA Technical Reports Server (NTRS)
Goza, S. P.
1994-01-01
Creating, animating, and recording solid-shaded and wireframe three-dimensional geometric models can be of great assistance in the research and design phases of product development, in project planning, and in engineering analyses. SSM and OOM are application programs which together allow for interactive construction and manipulation of three-dimensional models of real-world objects as simple as boxes or as complex as Space Station Freedom. The output of SSM, in the form of binary files defining geometric three dimensional models, is used as input to OOM. Animation in OOM is done using 3D models from SSM as well as cameras and light sources. The animated results of OOM can be output to videotape recorders, film recorders, color printers and disk files. SSM and OOM are also available separately as MSC-21914 and MSC-22263, respectively. The Solid Surface Modeler (SSM) is an interactive graphics software application for solid-shaded and wireframe three-dimensional geometric modeling. The program has a versatile user interface that, in many cases, allows mouse input for intuitive operation or keyboard input when accuracy is critical. SSM can be used as a stand-alone model generation and display program and offers high-fidelity still image rendering. Models created in SSM can also be loaded into the Object Orientation Manipulator for animation or engineering simulation. The Object Orientation Manipulator (OOM) is an application program for creating, rendering, and recording three-dimensional computer-generated still and animated images. This is done using geometrically defined 3D models, cameras, and light sources, referred to collectively as animation elements. OOM does not provide the tools necessary to construct 3D models; instead, it imports binary format model files generated by the Solid Surface Modeler (SSM). Model files stored in other formats must be converted to the SSM binary format before they can be used in OOM. SSM is available as MSC-21914 or as part of the SSM/OOM bundle, COS-10047. Among OOM's features are collision detection (with visual and audio feedback), the capability to define and manipulate hierarchical relationships between animation elements, stereographic display, and ray- traced rendering. OOM uses Euler angle transformations for calculating the results of translation and rotation operations. OOM and SSM are written in C-language for implementation on SGI IRIS 4D series workstations running the IRIX operating system. A minimum of 8Mb of RAM is recommended for each program. The standard distribution medium for this program package is a .25 inch streaming magnetic IRIX tape cartridge in UNIX tar format. These versions of OOM and SSM were released in 1993.
Iris Freckles a Potential Biomarker for Chronic Sun Damage.
Schwab, Christoph; Mayer, Christoph; Zalaudek, Iris; Riedl, Regina; Richtig, Markus; Wackernagel, Werner; Hofmann-Wellenhof, Rainer; Richtig, Georg; Langmann, Gerald; Tarmann, Lisa; Wedrich, Andreas; Richtig, Erika
2017-05-01
To investigate the role of sunlight exposure in iris freckles formation. We prospectively examined volunteers attending a skin cancer screening program conducted by ophthalmologists and dermatologists. Frequency and topographical variability of iris freckles were noted and associated with behavioral and dermatologic characteristics indicating high sun exposure. Six hundred thirty-two participants (n = 360; 57% female) were examined. Mean age of all participants was 38.4 ± 18.4 years (range, 4-84 years). Of all individuals, 76.1% (n = 481) exhibited at least one iris freckle. Most freckles were observed in the inferior temporal quadrant. The presence of iris freckles was associated with higher age (participants with iris freckles: 41.8 ± 16.8 years versus participants without iris freckles: 27.6 ± 19.2 years), a high number of sunburns during lifetime (>10: 31% vs. 19%), sunlight-damaged skin (26% vs. 11%), presence of actinic lentigines (72% vs. 45%), and a high total nevus body count (>10; 78% vs. 67%). The association of iris freckles, behavioral factors, and dermatologic findings, as well as the topographical distribution, indicate that sunlight exposure may trigger the formation of iris freckles. The evaluation of iris freckles offers an easily accessible potential biomarker, which might be helpful in indicating sun damage on the skin associated with cutaneous malignancies. Furthermore, the evaluation of iris freckles could also be helpful in understanding the role of sunlight in several ophthalmologic diseases.
Chu, Michael JJ; Premkumar, Rakesh; Hickey, Anthony JR; Jiang, Yannan; Delahunt, Brett; Phillips, Anthony RJ; Bartlett, Adam SJR
2016-01-01
AIM: To assess the effects of ischemic preconditioning (IPC, 10-min ischemia/10-min reperfusion) on steatotic liver mitochondrial function after normothermic ischemia-reperfusion injury (IRI). METHODS: Sixty male Sprague-Dawley rats were fed 8-wk with either control chow or high-fat/high-sucrose diet inducing > 60% mixed steatosis. Three groups (n = 10/group) for each dietary state were tested: (1) the IRI group underwent 60 min partial hepatic ischemia and 4 h reperfusion; (2) the IPC group underwent IPC prior to same standard IRI; and (3) sham underwent the same surgery without IRI or IPC. Hepatic mitochondrial function was analyzed by oxygraphs. Mitochondrial Complex-I, Complex-II enzyme activity, serum alanine aminotransferase (ALT), and histological injury were measured. RESULTS: Steatotic-IRI livers had a greater increase in ALT (2476 ± 166 vs 1457 ± 103 IU/L, P < 0.01) and histological injury following IRI compared to the lean liver group. Steatotic-IRI demonstrated lower Complex-I activity at baseline [78.4 ± 2.5 vs 116.4 ± 6.0 nmol/(min.mg protein), P < 0.001] and following IRI [28.0 ± 6.2 vs 104.3 ± 12.6 nmol/(min.mg protein), P < 0.001]. Steatotic-IRI also demonstrated impaired Complex-I function post-IRI compared to the lean liver IRI group. Complex-II activity was unaffected by hepatic steatosis or IRI. Lean liver mitochondrial function was unchanged following IRI. IPC normalized ALT and histological injury in steatotic livers but had no effect on overall steatotic liver mitochondrial function or individual mitochondrial complex enzyme activities. CONCLUSION: Warm IRI impairs steatotic liver Complex-I activity and function. The protective effects of IPC in steatotic livers may not be mediated through mitochondria. PMID:27217699
Park, Ji Hun; Kho, Min Chol; Oh, Hyun Cheol; Kim, Youn Chul; Yoon, Jung Joo; Lee, Yun Jung; Kang, Dae Gill; Lee, Ho Sub
2018-05-13
Renal ischemia-reperfusion injury (IRI), an important cause of acute kidney injury (AKI), causes increased renal tubular injury and microvascular inflammation. 1,[Formula: see text]2,[Formula: see text]3,[Formula: see text]4,[Formula: see text]6-penta-O-galloyl-[Formula: see text]-D-glucose (PGG) from Galla rhois has anticancer, anti-oxidation and angiogenesis effects. We examined protective effects of PGG on IRI-induced acute AKI. Clamping both renal arteries for 45[Formula: see text]min induced isechemia and then reperfusion. Treatment with PGG (10[Formula: see text]mg/kg/day and 50[Formula: see text]mg/kg/day for four days) significantly ameliorated urine volume, urine osmolality, creatinine clearance (Ccr) and blood urea nitrogen (BUN). In addition, PGG increased aquaporine 1/2/3, Na[Formula: see text]-K[Formula: see text]-ATPase and urea transporter (UT-B) and decreased ICAM-1, MCP-1, and HMGB-1 expression. In this histopathologic study, PGG improved glomerular and tubular damage. Immunohistochemistry results showed that PGG increased aquaporine 1/2, and Na[Formula: see text]-K[Formula: see text] ATPase and decreased ICAM-1 expression. These findings suggest that PGG ameliorates tubular injury including tubular dysfunction and microvascular inflammation in IRI-induced AKI rats.
At present, there are IRIS RfDs for two commercial PCB mixtures: Aroclor 1016 and Aroclor 1254. There is no IRIS RfD for complex PCB mixtures in general; and the RfDs for Aroclor 1016 and Aroclor 1254 were last updated in 1993 and 1994, respectively. The new assessment will integ...
Optical Coherence Tomography Angiography Features of Iris Racemose Hemangioma in 4 Cases.
Chien, Jason L; Sioufi, Kareem; Ferenczy, Sandor; Say, Emil Anthony T; Shields, Carol L
2017-10-01
Optical coherence tomography angiography (OCTA) allows visualization of iris racemose hemangioma course and its relation to the normal iris microvasculature. To describe OCTA features of iris racemose hemangioma. Descriptive, noncomparative case series at a tertiary referral center (Ocular Oncology Service of Wills Eye Hospital). Patients diagnosed with unilateral iris racemose hemangioma were included in the study. Features of iris racemose hemangioma on OCTA. Four eyes of 4 patients with unilateral iris racemose hemangioma were included in the study. Mean patient age was 50 years, all patients were white, and Snellen visual acuity was 20/20 in each case. All eyes had sectoral iris racemose hemangioma without associated iris or ciliary body solid tumor on clinical examination and ultrasound biomicroscopy. By anterior segment OCT, the racemose hemangioma was partially visualized in all cases. By OCTA, the hemangioma was clearly visualized as a uniform large-caliber vascular tortuous loop with intense flow characteristics superimposed over small-caliber radial iris vessels against a background of low-signal iris stroma. The vascular course on OCTA resembled a light bulb filament (filament sign), arising from the peripheral iris (base of light bulb) and forming a tortuous loop on reaching its peak (midfilament) near the pupil (n = 3) or midzonal iris (n = 1), before returning to the peripheral iris (base of light bulb). Intravenous fluorescein angiography performed in 1 eye depicted the iris hemangioma; however, small-caliber radial iris vessels were more distinct on OCTA than intravenous fluorescein angiography. Optical coherence tomography angiography is a noninvasive vascular imaging modality that clearly depicts the looping course of iris racemose hemangioma. Optical coherence tomography angiography depicted fine details of radial iris vessels, not distinct on intravenous fluorescein angiography.
Iris metastasis of gastric adenocarcinoma.
Celebi, Ali Riza Cenk; Kilavuzoglu, Ayse Ebru; Altiparmak, U Emrah; Cosar, C Banu; Ozkiris, Abdullah
2016-03-08
Iris metastasis in patients with gastric cancer is extremely rare. Herein, it is aimed to report on a patient with gastric adenocarcinoma and iris metastasis. A 65-year-old patient with the history of gastric cancer was admitted for eye pain and eye redness on his left eye. There was ciliary injection, severe +4 cells with hypopyon in the anterior chamber and a solitary, friable, yellow-white, fleshy-creamy vascularized 2 mm × 4 mm mass on the upper nasal part of the iris within the left eye. The presented patient's mass lesion in the iris fulfilled the criteria of the metastatic iris lesion's appearance. The ocular metastasis occurred during chemotherapy. Iris metastasis can masquerade as iridocyclitis with pseudohypopyon or glaucoma. In patients with a history of gastric cancer that present with an iris mass, uveitis, and high intraocular pressure, ocular metastasis of gastric cancer should be a consideration.
Goovaerts, Odin; Jennes, Wim; Massinga-Loembé, Marguerite; Ondoa, Pascale; Ceulemans, Ann; Vereecken, Chris; Worodria, William; Mayanja-Kizza, Harriet; Colebunders, Robert; Kestens, Luc
2015-01-01
Background Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) is an inflammatory complication in HIV-TB co-infected patients receiving antiretroviral therapy (ART). The role of disturbed T cell reconstitution in TB-IRIS is not well understood. We investigated T cell activation and maturation profiles in patients who developed TB-IRIS at different intervals during ART. Methods Twenty-two HIV-TB patients who developed early-onset TB-IRIS and 10 who developed late-onset TB-IRIS were matched for age, sex and CD4 count to equal numbers of HIV-TB patients who did not develop TB-IRIS. Flow cytometry analysis was performed on fresh blood, drawn before and after ART initiation and during TB-IRIS events. T cell activation and maturation was measured on CD4+ and CD8+ T cells using CD45RO, CD38, HLA-DR, CCR7 and CD27 antibodies. Results CD8+ T cell activation before ART was decreased in both early-onset (77% vs. 82%, p = 0.014) and late-onset (71% vs. 83%, p = 0.012) TB-IRIS patients compared to non-IRIS controls. After ART initiation, the observed differences in T cell activation disappeared. During late-onset, but not early-onset TB-IRIS, we observed a skewing from memory to terminal effector CD4+ and CD8+ T cell populations (p≤0.028). Conclusion Our data provide evidence of reduced CD8+ T cell activation before ART as a common predisposing factor of early- and late-onset TB-IRIS. The occurrence of TB-IRIS itself was not marked by an over-activated CD8+ T cell compartment. Late- but not early-onset TB-IRIS was characterized by a more terminally differentiated T cell phenotype. PMID:26208109
IRIS Toxicological Review of Dichloromethane (Methylene ...
EPA has finalized the Toxicological Review of Dichloromethane (Methylene Chloride): In support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. This document presents background information and justification for the Intergrated Risk Information System (IRIS) Summary of the hazard and dose-response assessment of dichloromethane. IRIS Summaries may include oral reference dose (RfD) and inhalation reference concentration (RfC) values for chronic and other exposure durations, and a carcinogencity assessment. Internet/NCEA web site
NASA Astrophysics Data System (ADS)
Nakamoto, M.; Uemura, R.; Gibo, M.; Mishima, S.; Asami, R.
2013-12-01
Oxygen isotope record in stalagmites is useful to reconstruct past environmental changes. However, the interpretation of calcite isotope record is not straightforward because it is affected by various factors such as amount of precipitation and temperature. Water isotope composition of fluid inclusions, and oxygen isotope difference between water and host calcite, from stalagmite are potentially important proxies to estimate the paleo-temperature. Recently, infrared spectroscopy (IRIS) has been widely used for stable isotope ratio measurement of water. Unlike traditional isotope mass spectrometer (IRMS), the IRIS does not require pre-treatment processes (e.g., high-temperature furnace or equilibration device). A limitation of IRIS is that commercially available IRIS systems need large sample volume (1 - 2 micro litres) for liquid water measurement. In this study, we first developed a device suitable for measurement of smaller volume of water, and tested two extraction methods (thermal extraction and mechanical crushing). Oxygen and hydrogen isotope ratios of water were measured using cavity ring down spectroscopy (IRIS: WS-CRDS Picarro L2120-i, L2130-i). Stalagmite samples, which appear to be still growing, were collected in several caves in Okinawa, Japan. Reproducibility of a reference water (0.1 micro litres) was within 0.2 permil for δ18O and 1 permil for δD. The results showed that the IRIS is useful for small amount discrete sample. Although the δ18O value of inclusion water generally showed values resembling those of cave dripwaters, the δD value showed large depletion against that of dripwaters. The δD deviation was reduced at lower temperature extraction, suggesting that the erroneous δD values would be caused by spectral interference from organic contaminants produced by thermal decomposition.
IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...
The known toxic effects of perchloroethylene will be summarized, with citations from current scientific literature. The critical effects will be identified, and from this the RfD and RfC and cancer unit risk factors will be derived. The RfD and RfC are reference doses and air concentrations that are generally regarded as safe under conditions of chronic exposure. The cancer unit risks in air and drinking water are the estimated lifetime cancer risks expected to occur from a lifetime exposure to a concentration of 1 microgram per cubic meter in the air and to a drinking water concentration of 1 microgram per liter. This summary document will be peer reviewed within the Agency and by experts outside the Agency according to the standard IRIS procedures. For up-to-date project schedules see IRIS Track at http://cfpub.epa.gov/iristrac/index.cfm The U.S. EPA is conducting a new health assessment of tetrachloroethylene that will appear on the Agency's online database, the Integrated Risk Information System (IRIS). IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment process, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific sit
Yu, Dawei; Yang, Min; Qi, Lu; Liu, Mengmeng; Wang, Yawei; Wei, Yuansong
2017-10-01
The effect of aeration on the pile matrix temperature was investigated using thermocouples and Infrared Thermal Imager (IRI) for temperature sensing, and Computational Fluid Dynamics (CFD) for modelling of temperature variation during aeration in a full-scale sludge biodrying plant. With aeration saving of 20%, the improved strategy speeded up biodrying from 21 days to 14 days, while achieving similar drying effect. A persistent thermocouple recorded the one-dimensional (1D) total temperature variation of all aeration strategies. The IRI captured the rapid two-dimensional (2D) pile temperature dropped from 72.5 °C to 30.3 °C during 6 min of aeration, which mechanism suggested as the latent heat of moisture evaporation and sensible heat of air exchange. The CFD three-dimensional (3D) CFD results highlight the importance of latent heat rather than sensible heat. Therefore, the pile temperature drop inferred is ΔT = 5.38 °C theoretically and ΔT = 5.17 ± 4.56 °C practically, per unit of MC removed. These findings also emphasize the possibility of a pile temperature valley, due to excessive aeration under unsaturated vapour conditions. Surface temperature monitored by IRI coupled with 3D temperature simulated by CFD rapidly gives a clear matrix temperature evolution, empowering biodrying by more accurate temperature and aeration. Copyright © 2017 Elsevier Ltd. All rights reserved.
IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...
EPA's assessment of the noncancer health effects and carcinogenic potential of 1,2,3-trichloropropane (TCP) was added to the IRIS database in 1990. The IRIS program is updating the IRIS assessment for TCP. This update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for TCP will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of TCP (RfD and RfC) and a cancer assessment. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency review, and external scientific peer review. The final products will constitute the Agency's opinion on the toxicity of TCP. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for 1,2,3-trichloropropane. IRIS is an EPA database containing the Agency's consensus scientific positions on potential adverse human effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment process, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in
Foldable iris-fixated intraocular lens implantation in children.
Ryan, Andrea; Hartnett, Claire; Lanigan, Bernadette; O'Keefe, Michael
2012-09-01
To describe the results of foldable iris-fixated intraocular lens (IOL) implantation in children. Children with high bilateral or unilateral myopia who were intolerant of spectacle or contact lens correction were implanted with an iris-fixated foldable IOL and prospectively followed. We measured pre- and postoperative visual acuity, refraction, endothelial cell density (ECD) and National Eye Institute Visual Functioning Questionnaire-25. Eleven eyes of six children were implanted. Indications were high bilateral myopia in children with comorbid neurobehavioural disorders, high anisometropia and high myopic astigmatism. Mean preoperative spherical equivalent (SE) refraction was -14.6 dioptres (D)±4.2 SD. Mean follow-up was 15 months. Postoperative SE refraction was -2.40 D±2.40 SD. Corrected distance visual acuity (CDVA) improved from mean logMAR 0.84±0.4 SD to postoperative 0.67±0.34 SD (p=0.005). CDVA was reduced because of coexistent ocular disorders and amblyopia. Vision-related quality of life (QOL) measures improved significantly. There were no intraoperative or postoperative serious complications. Foldable iris-fixated IOL insertion can give a significant improvement in vision and in vision-related QOL in a subset of paediatric patients with special refractive needs who are intolerant to conventional treatment. Long-term follow-up is required for monitoring of ECD. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
The Ionosphere Real-Time Assimilative Model, IRTAM - A Status Report
NASA Astrophysics Data System (ADS)
Reinisch, Bodo; Galkin, Ivan; Huang, Xueqin; Vesnin, Artem; Bilitza, Dieter
2014-05-01
Ionospheric models are generally unable to correctly predict the effects of space weather events on the ionosphere. Taking advantage of today's real-time availability of measured electron density profiles of the bottomside ionosphere, we have developed a technique "IRTAM" to specify real-time foF2 and hmF2 global maps. The measured data arrive at the Lowell GIRO Data Center (LGDC) from some ~70 ionosonde stations of the Global Ionosphere Radio Observatory (GIRO) [Reinisch and Galkin, 2011], usually at a 15 min cadence, and are ingested in LGDC's databases (http://ulcar.uml.edu/DIDBase/). We use the International Reference Ionosphere (IRI) electron density model [Bilitza et al., 2011] as the background model. It is an empirical monthly median model that critically depends on the correct values of the F2 layer peak height hmF2 and density NmF2 (or critical frequency foF2). The IRI model uses the so-called CCIR (or URSI) coefficients for the specification of the median foF2 and hmF2 maps. IRTAM assimilates the measured GIRO data in IRI by "adjusting" the CCIR coefficients on-the-fly. The updated maps of foF2 and hmF2 for the last 24 hours before now-time are continuously displayed on http://giro.uml.edu/RTAM [Galkin et al., 2012]. The "adjusted" bottomside profiles can be extended to the topside by using the new Vary-Chap topside profile model [Nsumei et al., 2012] which extends the profile from hmF2 to the plasmasphere. References Bilitza D., L.-A. McKinnell, B. Reinisch, and T. Fuller-Rowell (2011), The International Reference Ionosphere (IRI) today and in the future, J. Geodesy, 85:909-920, DOI 10.1007/s00190-010-0427-x Galkin, I. A., B. W. Reinisch, X. Huang, and D. Bilitza (2012), Assimilation of GIRO Data into a Real-Time IRI, Radio Sci., 47, RS0L07, doi:10.1029/2011RS004952. Nsumei, P., B. W. Reinisch, X. Huang, and D. Bilitza (2012), New Vary-Chap profile of the topside ionosphere electron density distribution for use with the IRI Model and the GIRO real time data, Radio Sci., doi:10.1029/2012RS004989. Reinisch, B. W. and I. A. Galkin (2011), Global Ionospheric Radio Observatory (GIRO), Earth, Planets and Space, 63(4), 377-381.
IRIS Toxicological Review and Summary Documents for N ...
EPA's assessment of the noncancer health effects and carcinogenic potential of n-hexane was last prepared and added to the IRIS data base in 1990. The IRIS program is updating the IRIS assessment for n-hexane; this update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for n-hexane will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of n-hexane (RfD and RfC) and a cancer assessment, where supported by available data. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency review, and external scientific peer review. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for n-hexane. The outcome of this project is an updated Toxicological Review and IRIS Summary for n-Hexane that will be entered into the IRIS database. IRIS is an EPA data base containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment
Evaluation of very long baseline interferometry atmospheric modeling improvements
NASA Technical Reports Server (NTRS)
Macmillan, D. S.; Ma, C.
1994-01-01
We determine the improvement in baseline length precision and accuracy using new atmospheric delay mapping functions and MTT by analyzing the NASA Crustal Dynamics Project research and development (R&D) experiments and the International Radio Interferometric Surveying (IRIS) A experiments. These mapping functions reduce baseline length scatter by about 20% below that using the CfA2.2 dry and Chao wet mapping functions. With the newer mapping functions, average station vertical scatter inferred from observed length precision (given by length repeatabilites) is 11.4 mm for the 1987-1990 monthly R&D series of experiments and 5.6 mm for the 3-week-long extended research and development experiment (ERDE) series. The inferred monthly R&D station vertical scatter is reduced by 2 mm or by 7 mm is a root-sum-square (rss) sense. Length repeatabilities are optimum when observations below a 7-8 deg elevation cutoff are removed from the geodetic solution. Analyses of IRIS-A data from 1984 through 1991 and the monthly R&D experiments both yielded a nonatmospheric unmodeled station vertical error or about 8 mm. In addition, analysis of the IRIS-A exeriments revealed systematic effects in the evolution of some baseline length measurements. The length rate of change has an apparent acceleration, and the length evolution has a quasi-annual signature. We show that the origin of these effects is unlikely to be related to atmospheric modeling errors. Rates of change of the transatlantic Westford-Wettzell and Richmond-Wettzell baseline lengths calculated from 1988 through 1991 agree with the NUVEL-1 plate motion model (Argus and Gordon, 1991) to within 1 mm/yr. Short-term (less than 90 days) variations of IRIS-A baseline length measurements contribute more than 90% of the observed scatter about a best fit line, and this short-term scatter has large variations on an annual time scale.
A novel iris patterns matching algorithm of weighted polar frequency correlation
NASA Astrophysics Data System (ADS)
Zhao, Weijie; Jiang, Linhua
2014-11-01
Iris recognition is recognized as one of the most accurate techniques for biometric authentication. In this paper, we present a novel correlation method - Weighted Polar Frequency Correlation(WPFC) - to match and evaluate two iris images, actually it can also be used for evaluating the similarity of any two images. The WPFC method is a novel matching and evaluating method for iris image matching, which is complete different from the conventional methods. For instance, the classical John Daugman's method of iris recognition uses 2D Gabor wavelets to extract features of iris image into a compact bit stream, and then matching two bit streams with hamming distance. Our new method is based on the correlation in the polar coordinate system in frequency domain with regulated weights. The new method is motivated by the observation that the pattern of iris that contains far more information for recognition is fine structure at high frequency other than the gross shapes of iris images. Therefore, we transform iris images into frequency domain and set different weights to frequencies. Then calculate the correlation of two iris images in frequency domain. We evaluate the iris images by summing the discrete correlation values with regulated weights, comparing the value with preset threshold to tell whether these two iris images are captured from the same person or not. Experiments are carried out on both CASIA database and self-obtained images. The results show that our method is functional and reliable. Our method provides a new prospect for iris recognition system.
2013-01-01
Background CD4+ T cell activation indicators have been reported to be a common phenomenon underlying diverse manifestations of immune reconstitution inflammatory syndrome (IRIS). However, we have found that a high frequency of circulating CD8+ T cells is a specific risk factor for mycobacterial IRIS. Therefore, we investigated whether CD8+ T cells from patients who develop TB IRIS were specifically activated. Methods We obtained PBMCs from HIV+ patients prior to and 4, 8, 12, 24, 52 and 104 weeks after initiating antiretroviral therapy. CD38 and HLADR expression on naive, central memory and effector memory CD8+ and CD4+ T cells were determined by flow cytometry. Absolute counts and frequencies of CD8+ T cell subsets were compared between patients who developed TB IRIS, who developed other IRIS forms and who remained IRIS-free. Results TB IRIS patients showed significantly higher counts of naive CD8+ T cells than the other groups at most time points, with a contraction of the effector memory subpopulation occurring later in the follow-up period. Activated (CD38+ HLADR+) CD8+ T cells from all groups decreased with treatment but transiently peaked in TB IRIS patients. This increase was due to an increase in activated naive CD8+ T cell counts during IRIS. Additionally, the CD8+ T cell subpopulations of TB IRIS patients expressed HLADR without CD38 more frequently and expressed CD38 without HLADR less frequently than cells from other groups. Conclusions CD8+ T cell activation is specifically relevant to TB IRIS. Different IRIS forms may involve different alterations in T cell subsets, suggesting different underlying inflammatory processes. PMID:23688318
U.S. - UK - Canada Trilateral Symposium
2009-10-02
e . 4. Procedures for intra-community arms transfers simplified. 5 Retransfer controls disco raged b t m st be. u u u complied with. Li d...IRIS – T • Airbus A310 refueller 10 FUTURE OF TRANSATLANTIC ARMAMENTS COOPERATION 1996 VISION – “I believe that national security – ours and that
Development of IR imaging system simulator
NASA Astrophysics Data System (ADS)
Xiang, Xinglang; He, Guojing; Dong, Weike; Dong, Lu
2017-02-01
To overcome the disadvantages of the tradition semi-physical simulation and injection simulation equipment in the performance evaluation of the infrared imaging system (IRIS), a low-cost and reconfigurable IRIS simulator, which can simulate the realistic physical process of infrared imaging, is proposed to test and evaluate the performance of the IRIS. According to the theoretical simulation framework and the theoretical models of the IRIS, the architecture of the IRIS simulator is constructed. The 3D scenes are generated and the infrared atmospheric transmission effects are simulated using OGRE technology in real-time on the computer. The physical effects of the IRIS are classified as the signal response characteristic, modulation transfer characteristic and noise characteristic, and they are simulated on the single-board signal processing platform based on the core processor FPGA in real-time using high-speed parallel computation method.
Multimodal biometric digital watermarking on immigrant visas for homeland security
NASA Astrophysics Data System (ADS)
Sasi, Sreela; Tamhane, Kirti C.; Rajappa, Mahesh B.
2004-08-01
Passengers with immigrant Visa's are a major concern to the International Airports due to the various fraud operations identified. To curb tampering of genuine Visa, the Visa's should contain human identification information. Biometric characteristic is a common and reliable way to authenticate the identity of an individual [1]. A Multimodal Biometric Human Identification System (MBHIS) that integrates iris code, DNA fingerprint, and the passport number on the Visa photograph using digital watermarking scheme is presented. Digital Watermarking technique is well suited for any system requiring high security [2]. Ophthalmologists [3], [4], [5] suggested that iris scan is an accurate and nonintrusive optical fingerprint. DNA sequence can be used as a genetic barcode [6], [7]. While issuing Visa at the US consulates, the DNA sequence isolated from saliva, the iris code and passport number shall be digitally watermarked in the Visa photograph. This information is also recorded in the 'immigrant database'. A 'forward watermarking phase' combines a 2-D DWT transformed digital photograph with the personal identification information. A 'detection phase' extracts the watermarked information from this VISA photograph at the port of entry, from which iris code can be used for identification and DNA biometric for authentication, if an anomaly arises.
Tan, Chun-Wei; Kumar, Ajay
2014-07-10
Accurate iris recognition from the distantly acquired face or eye images requires development of effective strategies which can account for significant variations in the segmented iris image quality. Such variations can be highly correlated with the consistency of encoded iris features and the knowledge that such fragile bits can be exploited to improve matching accuracy. A non-linear approach to simultaneously account for both local consistency of iris bit and also the overall quality of the weight map is proposed. Our approach therefore more effectively penalizes the fragile bits while simultaneously rewarding more consistent bits. In order to achieve more stable characterization of local iris features, a Zernike moment-based phase encoding of iris features is proposed. Such Zernike moments-based phase features are computed from the partially overlapping regions to more effectively accommodate local pixel region variations in the normalized iris images. A joint strategy is adopted to simultaneously extract and combine both the global and localized iris features. The superiority of the proposed iris matching strategy is ascertained by providing comparison with several state-of-the-art iris matching algorithms on three publicly available databases: UBIRIS.v2, FRGC, CASIA.v4-distance. Our experimental results suggest that proposed strategy can achieve significant improvement in iris matching accuracy over those competing approaches in the literature, i.e., average improvement of 54.3%, 32.7% and 42.6% in equal error rates, respectively for UBIRIS.v2, FRGC, CASIA.v4-distance.
NASA Astrophysics Data System (ADS)
Arikan, Feza; Gulyaeva, Tamara; Sezen, Umut; Arikan, Orhan; Toker, Cenk; Hakan Tuna, MR.; Erdem, Esra
2016-07-01
International Reference Ionosphere is the most acknowledged climatic model of ionosphere that provides electron density profile and hourly, monthly median values of critical layer parameters of the ionosphere for a desired location, date and time between 60 to 2,000 km altitude. IRI is also accepted as the International Standard Ionosphere model. Recently, the IRI model is extended to the Global Positioning System (GPS) satellite orbital range of 20,000 km. The new version is called IRI-Plas and it can be obtained from http://ftp.izmiran.ru/pub/izmiran /SPIM/. A user-friendly online version is also provided at www.ionolab.org as a space weather service. Total Electron Content (TEC), which is defined as the line integral of electron density on a given ray path, is an observable parameter that can be estimated from earth based GPS receivers in a cost-effective manner as GPS-TEC. One of the most important advantages of IRI-Plas is the possible input of GPS-TEC to update the background deterministic ionospheric model to the current ionospheric state. This option is highly useful in regional and global tomography studies and HF link assessments. IONOLAB group currently implements IRI-Plas as a background model and updates the ionospheric state using GPS-TEC in IONOLAB-CIT and IONOLAB-RAY algorithms. The improved state of ionosphere allows the most reliable 4-D imaging of electron density profiles and HF and satellite communication link simulations.This study is supported by TUBITAK 115E915 and joint TUBITAK 114E092 and AS CR 14/001.
van Bilsen, Ward P H; van den Berg, Charlotte H S B; Rijnders, Bart J A; Brinkman, Kees; Mulder, Jan W; Gelinck, Luc B S; Hoepelman, Andy I M; Wit, Ferdinand W N M; van de Beek, Diederik; Prins, Jan M
2017-06-19
To investigate the incidence and risk factors of immune reconstitution inflammatory syndrome (IRIS) associated with toxoplasmic encephalitis (TE) in patients starting combination antiretroviral therapy (cART). A historical multicenter cohort study. We included all HIV-infected patients diagnosed with toxoplasmic encephalitis in six Dutch hospitals between 1996 and 2016. Diagnosis of TE-IRIS was made using predefined IRIS criteria. We distinguished paradoxical TE-IRIS (worsening of underlying treated infection) from unmasking TE-IRIS (unmasking of subclinical infection after start of cART). We compared CD4 cell count, plasma viral load and timing of cART initiation between patients with and without paradoxical TE-IRIS. A total of 211 toxoplasmic encephalitis cases were included. Among 143 cases at risk for paradoxical TE-IRIS, we identified five cases of paradoxical TE-IRIS (3.5%). In six other cases, we could not differentiate paradoxical TE-IRIS from recurrence of disease due to inadequate secondary Toxoplasma prophylaxis. There was no difference in time between start of toxoplasmic encephalitis treatment and cART initiation for patients who did or did not develop paradoxical TE-IRIS (P = 0.50). Within the group of 2228 patients who started cART while having a CD4 cell count below 200 × 10 cells/l and receiving adequate primary prophylaxis, we identified eight cases of unmasking TE-IRIS (0.36%). Unmasking TE-IRIS could not be differentiated from a newly occurring toxoplasmic encephalitis in six other patients, as they were not receiving adequate primary prophylaxis against Toxoplasma. Unmasking TE-IRIS was rare in this cohort, whereas paradoxical TE-IRIS did occur more often. We found no relationship between the timing of cART initiation and the occurrence of paradoxical TE-IRIS.
Tun, Tin A; Chua, Jacqueline; Shi, Yuan; Sidhartha, Elizabeth; Thakku, Sri Gowtham; Shei, William; Tan, Marcus Chiang Lee; Quah, Joanne Hui Min; Aung, Tin; Cheng, Ching-Yu
2016-12-01
To characterise the association of iris surface features (crypts, furrows and colour) with iris volume and curvature assessed by swept-source optical coherence tomography (SSOCT) in Asian eyes. Iris crypts (by number and size) and furrows (by number and circumferential extent) were graded from iris photographs. Iris colour was measured by a customised algorithm written on MATLAB (MathWorks, Natick, Massachusetts, USA). The iris was imaged by SSOCT (SS-1000, CASIA, Tomey, Nagoya, Japan). The associations of surface features with iris parameters were analysed using a generalised estimating equation. A total of 1704 subjects (3297 eyes) were included in the analysis. The majority was Chinese (86.4%), and 63.2% were females, and their mean age (±SD) was 61.4±6.6 years. After adjusting for age, sex, ethnicity, pupil size and corneal arcus, higher iris crypt grade was independently associated with smaller iris volume (β=-0.54, p<0.001), whereas darker irides and higher iris furrow grade were associated with larger iris volume (β=-0.041, p<0.001) and (β=0.233, p<0.001), respectively. Lighter coloured irides with more crypts and/or more furrows were also associated with less convexity (crypts: β=-0.003, p=0.03; furrows: β=-0.004, p=0.007; and colour: β=-0.001, p=0.005). Iris surface features were highly correlated with iris volume and curvature. Irides with more crypts have a smaller volume; and darker irides with more furrows have a larger volume. Lighter irides with more crypts and/or furrows have less convexity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Limbus Impact on Off-angle Iris Degradation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J
The accuracy of iris recognition depends on the quality of data capture and is negatively affected by several factors such as angle, occlusion, and dilation. Off-angle iris recognition is a new research focus in biometrics that tries to address several issues including corneal refraction, complex 3D iris texture, and blur. In this paper, we present an additional significant challenge that degrades the performance of the off-angle iris recognition systems, called the limbus effect . The limbus is the region at the border of the cornea where the cornea joins the sclera. The limbus is a semitransparent tissue that occludes amore » side portion of the iris plane. The amount of occluded iris texture on the side nearest the camera increases as the image acquisition angle increases. Without considering the role of the limbus effect, it is difficult to design an accurate off-angle iris recognition system. To the best of our knowledge, this is the first work that investigates the limbus effect in detail from a biometrics perspective. Based on results from real images and simulated experiments with real iris texture, the limbus effect increases the hamming distance score between frontal and off-angle iris images ranging from 0.05 to 0.2 depending upon the limbus height.« less
NASA Technical Reports Server (NTRS)
Lunsford, Myrtis Leigh
1998-01-01
The Army-NASA Virtual Innovations Laboratory (ANVIL) was recently created to provide virtual reality tools for performing Human Engineering and operations analysis for both NASA and the Army. The author's summer research project consisted of developing and refining these tools for NASA's Reusable Launch Vehicle (RLV) program. Several general simulations were developed for use by the ANVIL for the evaluation of the X34 Engine Changeout procedure. These simulations were developed with the software tool dVISE 4.0.0 produced by Division Inc. All software was run on an SGI Indigo2 High Impact. This paper describes the simulations, various problems encountered with the simulations, other summer activities, and possible work for the future. We first begin with a brief description of virtual reality systems.
Kaddour-Djebbar, I; Ansari, H R; Akhtar, R A; Abdel-Latif, A A
2005-01-01
There is evidence from our own laboratory and that of others that EP-receptor ligands are strong contractile agonists in bovine iris sphincter and that FP-receptor agonists are strong contractile agonists in cat iris sphincter. Here, we have investigated the effects of prostaglandin (PG) receptor agonists of the FP-, EP-, TP- and DP-class on myosin light chain (MLC) phosphorylation, p42/p44 MAP kinase phosphorylation and contraction in the iris sphincter of bovine and cat. Using three signal transduction mechanism assays, namely MLC phosphorylation, MAP kinase phosphorylation and contraction, we demonstrated that in bovine iris sphincter the rank order of potency of the PG agonists in the contractile and MLC phosphorylation assays is as follows: E2>U46619>F2alpha>D2, and in cat F2alpha>D2>E2>U46619. In the MAP kinase assay, in bovine iris sphincter the rank order of potency is E2>F2alpha and in cat F2alpha>E2. These conclusions are supported by the following findings: (1) In the contractile assay, in the bovine sphincter the EC50s for PGF2alpha, PGE2, U46619 and PGD2 were found to be 1.4x10(-7), 5.0x10(-9), 9.0x10(-9) and 1.3x10(-6)M, respectively, and the corresponding values in the cat were 1.9x10(-8), 2.3x10(-7), 1.5x10(-6) and 6.9x10(-8)M, respectively. (2) In the MLC phophorylation assay, in the bovine sphincter PGF2alpha, PGE2, U46619 and PGD2 increased MLC phophorylation by 118%, 165%, 153% and 72%, respectively, and the corresponding values in cat were 175%, 99%, 90% and 95%, respectively. (3) In the MAP kinase assay, in the bovine iris sphincter PGF2alpha and PGE2, increased MAP kinase phosphorylation by 276% and 328%, respectively, and the corresponding values in cat were 308% and 245%, respectively. The data presented demonstrate pronounced species differences in the effects of the prostanoids on the MLC kinase signaling pathway in bovine and cat irides and furthermore confirm the existence of FP-receptors in that of the bovine.
Tachado, S D; Akhtar, R A; Yousufzai, S Y; Abdel-Latif, A A
1991-12-01
The effects of substance P (SP) on inositol trisphosphate (IP3) accumulation, myosin light chain (MLC) phosphorylation, cAMP formation and contraction were studied in iris sphincter smooth muscle of different mammalian species. SP receptor density was also examined in membrane fractions from this tissue. The data obtained can be summarized as follows. (1) In the iris sphincters of rabbit, bovine and pig, SP receptors are coupled to the phospholipase C system, whereas in dog, cat and human these receptors are coupled to the adenylate cyclase system. (2) In those species which employ the phospholipase C system, SP induced IP3 accumulation, MLC phosphorylation and contraction in a dose-dependent manner; in contrast, in those species in which SP induced the formation of cAMP we found the neuropeptide to cause muscle relaxation. The findings on cAMP formation in intact tissue were confirmed in iris sphincter membranes. Both the effect of SP on IP3 accumulation in rabbit and bovine sphincters and its effect on cAMP formation in the dog were blocked by the SP antagonist, (D-Pro2, D-Trp7, 9)-SP. (3) The density of SP receptors in rabbit, bovine and dog were found to be 227, 110.9 and 13.6 fmol mg-1 protein, respectively, and the Kd values were 1.9, 1.8 and 1.3 nM, respectively. (4) Of the neuropeptides investigated SP, neurokinin A and neurokinin B had significant stimulatory effects on IP3 accumulation and on contraction in the rabbit iris sphincter; however, neither neurokinin Y nor the calcitonin gene-related peptide (CGRP) had any effect on these responses. In addition, none of the neuropeptides studied had any effect on IP3 or on contraction in the dog iris sphincter. While it is possible that SP may have dual actions, with the predominant action dependent on the species, the data presented could suggest the presence of two SP receptor subtypes, one coupled to phospholipase C and the other to adenylate cyclase. The results of this investigation indicate major species differences in biochemical and functional responsiveness to SP and in SP receptor density in the iris sphincter of the mammalian eye, and support a modulatory role for the neuropeptide in muscle response in this tissue.
Merckaert, Isabelle; Lewis, Florence; Delevallez, France; Herman, Sophie; Caillier, Marie; Delvaux, Nicole; Libert, Yves; Liénard, Aurore; Nogaret, Jean-Marie; Ogez, David; Scalliet, Pierre; Slachmuylder, Jean-Louis; Van Houtte, Paul; Razavi, Darius
2017-08-01
To compare in a multicenter randomized controlled trial the benefits in terms of anxiety regulation of a 15-session single-component group intervention (SGI) based on support with those of a 15-session multiple-component structured manualized group intervention (MGI) combining support with cognitive-behavioral and hypnosis components. Patients with nonmetastatic breast cancer were randomly assigned at the beginning of the survivorship period to the SGI (n = 83) or MGI (n = 87). Anxiety regulation was assessed, before and after group interventions, through an anxiety regulation task designed to assess their ability to regulate anxiety psychologically (anxiety levels) and physiologically (heart rates). Questionnaires were used to assess psychological distress, everyday anxiety regulation, and fear of recurrence. Group allocation was computer generated and concealed till baseline completion. Compared with patients in the SGI group (n = 77), patients attending the MGI group (n = 82) showed significantly reduced anxiety after a self-relaxation exercise (P = .006) and after exposure to anxiety triggers (P = .013) and reduced heart rates at different time points throughout the task (P = .001 to P = .047). The MGI participants also reported better everyday anxiety regulation (P = .005), greater use of fear of recurrence-related coping strategies (P = .022), and greater reduction in fear of recurrence-related psychological distress (P = .017) compared with the SGI group. This study shows that an MGI combining support with cognitive-behavioral techniques and hypnosis is more effective than an SGI based only on support in improving anxiety regulation in patients with breast cancer. Copyright © 2016 John Wiley & Sons, Ltd.
Real-time synchronized multiple-sensor IR/EO scene generation utilizing the SGI Onyx2
NASA Astrophysics Data System (ADS)
Makar, Robert J.; O'Toole, Brian E.
1998-07-01
An approach to utilize the symmetric multiprocessing environment of the Silicon Graphics Inc.R (SGI) Onyx2TM has been developed to support the generation of IR/EO scenes in real-time. This development, supported by the Naval Air Warfare Center Aircraft Division (NAWC/AD), focuses on high frame rate hardware-in-the-loop testing of multiple sensor avionics systems. In the past, real-time IR/EO scene generators have been developed as custom architectures that were often expensive and difficult to maintain. Previous COTS scene generation systems, designed and optimized for visual simulation, could not be adapted for accurate IR/EO sensor stimulation. The new Onyx2 connection mesh architecture made it possible to develop a more economical system while maintaining the fidelity needed to stimulate actual sensors. An SGI based Real-time IR/EO Scene Simulator (RISS) system was developed to utilize the Onyx2's fast multiprocessing hardware to perform real-time IR/EO scene radiance calculations. During real-time scene simulation, the multiprocessors are used to update polygon vertex locations and compute radiometrically accurate floating point radiance values. The output of this process can be utilized to drive a variety of scene rendering engines. Recent advancements in COTS graphics systems, such as the Silicon Graphics InfiniteRealityR make a total COTS solution possible for some classes of sensors. This paper will discuss the critical technologies that apply to infrared scene generation and hardware-in-the-loop testing using SGI compatible hardware. Specifically, the application of RISS high-fidelity real-time radiance algorithms on the SGI Onyx2's multiprocessing hardware will be discussed. Also, issues relating to external real-time control of multiple synchronized scene generation channels will be addressed.
Wang, Z Y; Håkanson, R
1993-04-08
Tachykinin analogues, claimed to be selective NK1, NK2 and NK3 receptor agonists, contracted the isolated rabbit iris sphincter muscle in a concentration-dependent manner. The contractions were not modified by the enkephalinase inhibitor thiorphan and the angiotensin-converting enzyme inhibitor captopril (10(-5) M of each). The pD2 values for (Sar9,Met(O2)11)SP (NK1 receptor agonist), (Nle10)NKA(4-10) (NK2 receptor agonist) and (MePhe7)NKB (NK3 receptor agonist) were 8.3, 6.1 and 8.2, respectively. (Sar9,Met(O2)11)SP was the most efficacious of the three agonists. The results are compatible with the presence of NK1 and NK3 receptors. The low pD2 value for the NK2 agonist may reflect a lack of NK2 receptors and interaction of the NK2 agonist with NK1 receptors. The contraction caused by the NK1 receptor agonist was inhibited competitively by the highly selective NK1 receptor antagonist (+/-) CP-96,345; the pA2 value was 5.5. Also the contraction caused by the NK2 receptor agonist was inhibited competitively by (+/-) CP-96,345 with a pA2 value of 5.7, supporting the view that the two agonists (Sar9,Met(O2)11)SP and (Nle10)NKA(4-10) interact with the same receptor. The selective NK2 receptor antagonist actinomycin D did not affect the contraction caused by the NK2 receptor agonist. We conclude that the rabbit iris sphincter muscle contains NK1 and probably NK3 receptors. We obtained no evidence for the presence of NK2 receptors.
The SGI/Cray T3E: Experiences and Insights
NASA Technical Reports Server (NTRS)
Bernard, Lisa Hamet
1998-01-01
The NASA Goddard Space Flight Center is home to the fifth most powerful supercomputer in the world, a 1024 processor SGI/Cray T3E-600. The original 512 processor system was placed at Goddard in March, 1997 as part of a cooperative agreement between the High Performance Computing and Communications Program's Earth and Space Sciences Project (ESS) and SGI/Cray Research. The goal of this system is to facilitate achievement of the Project milestones of 10, 50 and 100 GFLOPS sustained performance on selected Earth and space science application codes. The additional 512 processors were purchased in March, 1998 by the NASA Earth Science Enterprise for the NASA Seasonal to Interannual Prediction Project (NSIPP). These two "halves" still operate as a single system, and must satisfy the unique requirements of both aforementioned groups, as well as guest researchers from the Earth, space, microgravity, manned space flight and aeronautics communities. Few large scalable parallel systems are configured for capability computing, so models are hard to find. This unique environment has created a challenging system administration task, and has yielded some insights into the supercomputing needs of the various NASA Enterprises, as well as insights into the strengths and weaknesses of the T3E architecture and software. The T3E is a distributed memory system in which the processing elements (PE's) are connected by a low latency, high bandwidth bidirectional 3-D torus. Due to the focus on high speed communication between PE's, the T3E requires PE's to be allocated contiguously per job. Further, jobs will only execute on the user specified number of PE's and PE timesharing is possible but impractical. With a highly varied job mix in both size and runtime of jobs, the resulting scenario is PE fragmentation and an inability to achieve near 100% utilization. SGI/Cray has provided several scheduling and configuration tools to minimize the impact of fragmentation. These tools include PScheD (the political scheduler), GRM (the global resource manager) and NQE (the Network Queuing Environment). Features and impact of these tools will be discussed, as will resulting performance and utilization data. As a distributed memory system, the T3E is designed to be programmed through explicit message passing. Consequently, certain assumptions related to code design are made by the operating system (UNICOS/mk) and its scheduling tools. With the exception of HPF, which does run on the T3E, however poorly, alternative programming styles have the potential to impact the T3E in unexpected and undesirable ways. Several examples will be presented (preceeded with the disclaimer, "Don't try this at home! Violators will be prosecuted!")
New data products available at the IRIS DMC
NASA Astrophysics Data System (ADS)
Trabant, C. M.; Bahavar, M.; Hutko, A.; Karstens, R.
2010-12-01
The research supported by the raw data from the observatories of NSF's EarthScope project are having tremendous impact on our understanding of the structure and geologic history of North America, how and why earthquakes occur and many other areas of modern geophysics. The IRIS Data Management Center (DMC) is the primary access point for EarthScope/USArray data and has embarked on a new effort to produce higher-level data products beyond raw time series in order to assist the community in extracting the highest value possible from these data. These new products will serve many purposes: stepping-stones for future research projects, data visualizations, research result comparisons and compilation of unique data sets as well as outreach material. To ensure community involvement in the development of new products the requirements and priorities are reviewed and approved by the IRIS Data Products Working Group (DPWG). Many new products are now available at the IRIS DMC. These include two event based products generated in near real time. 1) USArray Ground Motion Visualizations, routinely generated animations showing the both the vertical and horizontal seismic wavefields sweeping across the USArray Transportable Array from earthquakes around the world. 2) Event Plots, a suite of figures automatically generated following all M6.0+ events which include phase aligned record sections, global body wave envelope stacks, regional network vespagrams and source-time functions. 3) Earth Model Collaboration, a new web repository for community-supplied regional and global tomography models with the ability to preview, request and compare models. 4) EARS, the EarthScope Automated Receiver Survey, developed at the University of South Carolina, aims to calculate crustal thickness and bulk crustal properties beneath USArray stations as well as many other broadband stations whose data are archived at the IRIS DMC. 5) Archiving and distribution of Princeton 3D SEM and 1D synthetic seismograms generated for all Global CMT events. 6) Archiving and distribution of GPS displacement time series produced by the Plate Boundary Observatory. Other data products are under consideration and will be moved to the development pipeline once approved by the IRIS DPWG. Feedback on existing products and ideas for new products are welcome at any time.
Arsalan, Muhammad; Naqvi, Rizwan Ali; Kim, Dong Seop; Nguyen, Phong Ha; Owais, Muhammad; Park, Kang Ryoung
2018-01-01
The recent advancements in computer vision have opened new horizons for deploying biometric recognition algorithms in mobile and handheld devices. Similarly, iris recognition is now much needed in unconstraint scenarios with accuracy. These environments make the acquired iris image exhibit occlusion, low resolution, blur, unusual glint, ghost effect, and off-angles. The prevailing segmentation algorithms cannot cope with these constraints. In addition, owing to the unavailability of near-infrared (NIR) light, iris recognition in visible light environment makes the iris segmentation challenging with the noise of visible light. Deep learning with convolutional neural networks (CNN) has brought a considerable breakthrough in various applications. To address the iris segmentation issues in challenging situations by visible light and near-infrared light camera sensors, this paper proposes a densely connected fully convolutional network (IrisDenseNet), which can determine the true iris boundary even with inferior-quality images by using better information gradient flow between the dense blocks. In the experiments conducted, five datasets of visible light and NIR environments were used. For visible light environment, noisy iris challenge evaluation part-II (NICE-II selected from UBIRIS.v2 database) and mobile iris challenge evaluation (MICHE-I) datasets were used. For NIR environment, the institute of automation, Chinese academy of sciences (CASIA) v4.0 interval, CASIA v4.0 distance, and IIT Delhi v1.0 iris datasets were used. Experimental results showed the optimal segmentation of the proposed IrisDenseNet and its excellent performance over existing algorithms for all five datasets. PMID:29748495
Arsalan, Muhammad; Naqvi, Rizwan Ali; Kim, Dong Seop; Nguyen, Phong Ha; Owais, Muhammad; Park, Kang Ryoung
2018-05-10
The recent advancements in computer vision have opened new horizons for deploying biometric recognition algorithms in mobile and handheld devices. Similarly, iris recognition is now much needed in unconstraint scenarios with accuracy. These environments make the acquired iris image exhibit occlusion, low resolution, blur, unusual glint, ghost effect, and off-angles. The prevailing segmentation algorithms cannot cope with these constraints. In addition, owing to the unavailability of near-infrared (NIR) light, iris recognition in visible light environment makes the iris segmentation challenging with the noise of visible light. Deep learning with convolutional neural networks (CNN) has brought a considerable breakthrough in various applications. To address the iris segmentation issues in challenging situations by visible light and near-infrared light camera sensors, this paper proposes a densely connected fully convolutional network (IrisDenseNet), which can determine the true iris boundary even with inferior-quality images by using better information gradient flow between the dense blocks. In the experiments conducted, five datasets of visible light and NIR environments were used. For visible light environment, noisy iris challenge evaluation part-II (NICE-II selected from UBIRIS.v2 database) and mobile iris challenge evaluation (MICHE-I) datasets were used. For NIR environment, the institute of automation, Chinese academy of sciences (CASIA) v4.0 interval, CASIA v4.0 distance, and IIT Delhi v1.0 iris datasets were used. Experimental results showed the optimal segmentation of the proposed IrisDenseNet and its excellent performance over existing algorithms for all five datasets.
The Priority of Road Rehabilitation in Karanganyar Regency Using IRI Estimation from Roadroid
NASA Astrophysics Data System (ADS)
Achmadi, F.; Suprapto, M.; Setyawan, A.
2017-02-01
The IRI (International Roughness Index) is a road roughness index commonly obtained from measured longitudinal road profiles. This is one of the functional performance a surface of road pavement. Therefore, needs to be done evaluation and monitoring periodically to getting priority of road rehabilitation right on target. The IRI standard has commonly been used worldwide for evaluating road system. The Roadroid is an application to measure road quality with a website to view road quality. It is designed for Android smartphones, so we can easily measure and monitor the road and also use the camera for GPS-tagged photo. By using the built-in vibration sensor in smartphones, it is possible to collect IRI value which can be an indicator road conditions. This study attempts to explain the priority of road rehabilitation in Karanganyar Regency. The location of the study focused on a collector street (primary, secondary and locally road). The result of IRI estimation will be combined with other aspects that influences; land use, policy, the connectivity of road and traffic average daily. Based on IRI estimation using Roadroid, the road conditions in Karanganyar Regency can be described 59,60% were good (IRI<4,5) 21,30% fair (4,5
Vignesh, Ramachandran; Swathirajan, Chinnambedu R; Solomon, Sunil S; Shankar, Esaki Muthu; Murugavel, Kailapuri G
2017-01-01
Immune reconstitution inflammatory syndrome (IRIS) continues to be a complication in HIV/tuberculosis (TB) co-infected patients initiating highly active antiretroviral therapy (HAART). The aim of this study was to evaluate the risk factors associated with developing IRIS to identify a possible biomarker to predict or diagnose IRIS in patients initiating HAART. A total of 175 HIV/TB co-infected patients initiating HAART were followed up longitudinally during September 2010 to May 2013 attending a HIV care clinic in Chennai. Patients were followed up longitudinally after HAART initiation and baseline demographic, laboratory parameters and treatment characteristics between patients with IRIS events and those without IRIS events were compared. Chi-square or Fisher's exact test for categorical variables and a Wilcoxon rank-sum test for continuous variables were performed using SPSS, version 12.0 software. Patients with IRIS had a significantly lower median baseline CD4+ T-cell count (P = 0.0039). There were no differences in terms of sex, CD4 T-cell %, plasma viral load, time interval between initiating ATT and HAART between the IRIS and non-IRIS patients. Low CD4+ T-cell count (<100 cells/μL) could be used as a marker to screen and monitor patients initiating HAART.
Effect of iris registration on outcomes of FEMTOLASIK for myopia and myopic astigmatism.
Ghoreishi, Mohammad; Beni, Zahra Naderi; Beni, Afsaneh Naderi; Kianersi, Farzan
2017-09-05
To compare the visual and refractive outcomes after FEMTOLASIK with and without iris registration. In this randomized, prospective, comparative, contralateral eye study, 118 eyes of 59 patients with myopia and myopic astigmatism underwent LASIK using the Femto LDV femtosecond laser (160 µm) and the MEL80 with or without iris registration. For each patient, iris registration FEMTOLASIK was performed on one eye and non-iris registration FEMTOLASIK was performed on the other eye, assigned at random. Patients were evaluated before and 12 months. Uncorrected visual acuity, best-corrected visual acuity, manifest refraction, contrast sensitivity, and higher-order aberrations (HOAs) were evaluated. At 12 months, the mean UDVA was 0.002 ± 0.07 logMAR (20/19) in iris registration eyes and 0.00 ± 0.06 logMAR (20/24) in non-iris registration eyes (P = 0.9). 61% of iris registration eyes and 71.2% of non-iris registration eyes achieved a UDVA of 20/20 or better (P = 0.31); 98.3% of eyes with the iris registration FEMTOLASIK and 94.9% with the non-iris registration FEMTOLASIK were within ±0.50 D from emmetropia (P = 0.71). No statistically significant difference was found in postoperative contrast sensitivity between groups at 3, 6, 12, or 18 cycles/degree (P > 0.05). There was significant increase in total HOA root mean square in two groups. The mean error magnitude of surgically induced astigmatism 12 months postoperatively was -0.33 in iris registration eyes and -0.24 in the non-iris registration eyes (P = 0.36). FEMTOLASIK with and without iris registration provides similar results in myopic and myopic astigmatism patients.
An Inexpensive Real-Time Interactive Three Dimensional Flight Simulation System.
1987-06-01
irh ’.etp. the 4i, n. he Ii~ Pi~op 4’ WV o cl d m od 0 V d 0 i c IV 1 M A,.. wq li . .. . . . " VII. TARGET INTEGRATION A. GENERAL The primary ...kts 200 kts Direction 359.9 degrees 0 degrees From prelaunch 99 5* 0 0 4 5 @ G 2 3 00 ALT 01 Figure 9.6 IRIS Dial Box Fuctions 100 summary box for a...Description: The primary purpose of get tgt pos is to move the targets in the simulation. If the networking capability is in lise, the target positions for
Visual acuity, endothelial cell density and polymegathism after iris-fixated lens implantation.
Nassiri, Nader; Ghorbanhosseini, Saeedeh; Jafarzadehpur, Ebrahim; Kavousnezhad, Sara; Nassiri, Nariman; Sheibani, Kourosh
2018-01-01
The purpose of this study was to evaluate the visual acuity as well as endothelial cell density (ECD) and polymegathism after iris-fixated lens (Artiflex ® AC 401) implantation for correction of moderate to high myopia. In this retrospective cross-sectional study, 55 eyes from 29 patients undergoing iris-fixated lens implantation for correction of myopia (-5.00 to -15.00 D) from 2007 to 2014 were evaluated. Uncorrected visual acuity, best spectacle-corrected visual acuity, refraction, ECD and polymegathism (coefficient of variation [CV] in the sizes of endothelial cells) were measured preoperatively and 6 months postoperatively. In the sixth month of follow-up, the uncorrected vision acuity was 20/25 or better in 81.5% of the eyes. The best-corrected visual acuity was 20/30 or better in 96.3% of the eyes, and more than 92% of the eyes had a refraction score of ±1 D from the target refraction. The mean corneal ECD of patients before surgery was 2,803±339 cells/mm 2 , which changed to 2,744±369 cells/mm 2 six months after surgery ( p =0.142). CV in the sizes of endothelial cells before the surgery was 25.7%±7.1% and six months after surgery it was 25.9%±5.4% ( p =0.857). Artiflex iris-fixated lens implantation is a suitable and predictable method for correction of moderate to high myopia. There was no statistically significant change in ECD and polymegathism (CV in the sizes of endothelial cells) after 6 months of follow-up.
Software and Systems Test Track Architecture and Concept Definition
2007-05-01
Light 11.0 11.0 11.0 ASC Flex Free Software Foundation 2.5.31 2.5.31 2.5.31 ASC Fluent Fluent Inc. 6.2.26 6.2.26 6.2.26 6.2.26 ASC FMD ...11 ERDC Fluent Fluent 6.2.16 ERDC Fortran 77/90 compiler Compaq/Cray/SGI 7.4 7.4.3m 7.4.4m 5.6 ERDC FTA Platform 1.1 1.1 1.1 ERDC GAMESS
NAS Experiences of Porting CM Fortran Codes to HPF on IBM SP2 and SGI Power Challenge
NASA Technical Reports Server (NTRS)
Saini, Subhash
1995-01-01
Current Connection Machine (CM) Fortran codes developed for the CM-2 and the CM-5 represent an important class of parallel applications. Several users have employed CM Fortran codes in production mode on the CM-2 and the CM-5 for the last five to six years, constituting a heavy investment in terms of cost and time. With Thinking Machines Corporation's decision to withdraw from the hardware business and with the decommissioning of many CM-2 and CM-5 machines, the best way to protect the substantial investment in CM Fortran codes is to port the codes to High Performance Fortran (HPF) on highly parallel systems. HPF is very similar to CM Fortran and thus represents a natural transition. Conversion issues involved in porting CM Fortran codes on the CM-5 to HPF are presented. In particular, the differences between data distribution directives and the CM Fortran Utility Routines Library, as well as the equivalent functionality in the HPF Library are discussed. Several CM Fortran codes (Cannon algorithm for matrix-matrix multiplication, Linear solver Ax=b, 1-D convolution for 2-D datasets, Laplace's Equation solver, and Direct Simulation Monte Carlo (DSMC) codes have been ported to Subset HPF on the IBM SP2 and the SGI Power Challenge. Speedup ratios versus number of processors for the Linear solver and DSMC code are presented.
Towards online iris and periocular recognition under relaxed imaging constraints.
Tan, Chun-Wei; Kumar, Ajay
2013-10-01
Online iris recognition using distantly acquired images in a less imaging constrained environment requires the development of a efficient iris segmentation approach and recognition strategy that can exploit multiple features available for the potential identification. This paper presents an effective solution toward addressing such a problem. The developed iris segmentation approach exploits a random walker algorithm to efficiently estimate coarsely segmented iris images. These coarsely segmented iris images are postprocessed using a sequence of operations that can effectively improve the segmentation accuracy. The robustness of the proposed iris segmentation approach is ascertained by providing comparison with other state-of-the-art algorithms using publicly available UBIRIS.v2, FRGC, and CASIA.v4-distance databases. Our experimental results achieve improvement of 9.5%, 4.3%, and 25.7% in the average segmentation accuracy, respectively, for the UBIRIS.v2, FRGC, and CASIA.v4-distance databases, as compared with most competing approaches. We also exploit the simultaneously extracted periocular features to achieve significant performance improvement. The joint segmentation and combination strategy suggest promising results and achieve average improvement of 132.3%, 7.45%, and 17.5% in the recognition performance, respectively, from the UBIRIS.v2, FRGC, and CASIA.v4-distance databases, as compared with the related competing approaches.
Infrared polar brightening on Jupiter. III - Spectrometry from the Voyager 1 IRIS experiment
NASA Technical Reports Server (NTRS)
Kim, S. J.; Caldwell, J.; Rivolo, A. R.; Wagener, R.; Orton, G. S.
1985-01-01
Spectra from the Voyager 1 IRIS experiment confirm the existence of enhanced infrared emission near Jupiter's north magnetic pole in March 1979. The spectral characteristics of the enhanced emission are consistent with a Planck source function. A temperature-pressure profile is derived for the region near the north magnetic pole, from which quantitative abundance estimates of minor species are made. Some species previously detected on Jupiter, including CH3D, C2H2, and C2H6, have been observed again near the pole. Newly discovered species, not previously observed on Jupiter, include C2H4, C3H4, and C6H6. All of these species except CH3D appear to have enhanced abundances at the north polar region with respect to midlatitudes. Upper limits are determined for C4H2 and C3H8. The quantitative results are compared with model calculations based on ultraviolet results from the IUE satellite. The plausibility of the C6H6 identification is discussed in terms of the literature on C2H2 polymerization. The relation of C6H6 to cuprene is also discussed.
Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan
2016-03-01
To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1-4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.
NASA Astrophysics Data System (ADS)
Yoon, Soweon; Jung, Ho Gi; Park, Kang Ryoung; Kim, Jaihie
2009-03-01
Although iris recognition is one of the most accurate biometric technologies, it has not yet been widely used in practical applications. This is mainly due to user inconvenience during the image acquisition phase. Specifically, users try to adjust their eye position within small capture volume at a close distance from the system. To overcome these problems, we propose a novel iris image acquisition system that provides users with unconstrained environments: a large operating range, enabling movement from standing posture, and capturing good-quality iris images in an acceptable time. The proposed system has the following three contributions compared with previous works: (1) the capture volume is significantly increased by using a pan-tilt-zoom (PTZ) camera guided by a light stripe projection, (2) the iris location in the large capture volume is found fast due to 1-D vertical face searching from the user's horizontal position obtained by the light stripe projection, and (3) zooming and focusing on the user's irises at a distance are accurate and fast using the estimated 3-D position of a face by the light stripe projection and the PTZ camera. Experimental results show that the proposed system can capture good-quality iris images in 2.479 s on average at a distance of 1.5 to 3 m, while allowing a limited amount of movement by the user.
NASA Astrophysics Data System (ADS)
Denisenko, P. F.; Maltseva, O. A.; Sotsky, V. V.
2018-03-01
The method of correcting the daytime vertical profiles of electron plasma frequency in the low ionosphere from International Refererence Ionosphere (IRI) model in accordance with the measured data of the virtual heights and absorption of signal radiowaves (method A1) reflected from the bottom of E-region at vertical sounding (VS) is presented. The method is based on the replacement of the IRI model profile by an approximation of analytical dependence with parameters determined according to VS data and partially by the IRI model. The method is tested by the results of four joint ground-based and rocket experiments carried out in the 1970s at midlatitudes of the European part of Russia upon the launches of high-altitude geophysical rockets of the Vertical series. It is shown that the consideration of both virtual reflection heigths and absorption makes it possible to obtain electron density distributions that show the best agreement with the rocket measurements made at most height ranges in the D- and E-regions. In additional, the obtained distributions account more adequately than the IRI model for the contributions of D- and E-regions to absorption of signals reflected above these regions.
Association between iris constitution and apolipoprotein e gene polymorphism in hypertensives.
Um, Jae-Young; Hwang, Chung-Yeon; Hwang, Woo-Jun; Kang, Sung-Do; Do, Keum-Rok; Cho, Ju-Jang; Cho, Jae-Woon; Kim, Sung-Hoon; Shin, Tae-Yong; Kim, Yun-Kyung; Kim, Hyung-Min; Hong, Seung-Heon
2004-12-01
Iridology is a complementary and alternative medicine (CAM) that involves the diagnosis of medical conditions by noting irregularities of the pigmentation in the iris. Iris constitution has a strong familial aggregation and heredity is implicated. Apolipoprotein E (apoE) gene polymorphism is one of the most well-studied genetic markers for vascular diseases, including hypertension. In this study, we investigated the relationship between iris constitution and apoE polymorphism in hypertensives. We classified 87 hypertensives and 79 controls according to iris constitution and determined the apoE genotype of each individual. A significantly higher percentage of individuals with neurogenic constitutions was found in the hypertensive group when compared with the control group (chi(2) = 40.244, p < 0.001). In addition, a neurogenic constitution increased the relative risk for hypertension for subjects with an apo epsilon2 or an epsilon4 allele (chi(2) = 4.086, p = 0.049, odds ratio = 2.633, confidence interval = 1.004-6.905). Our results imply that a neurogenic iris constitution enhances the relative risk for hypertension in subjects with the apo epsilon2 or epsilon4 allele. Furthermore, we attempted to evaluate the efficacy of iris constitutional medicine and to find an association with hypertension.
Touré, Fousseyni S.; Ouwe-Missi-Oukem-Boyer, Odile; Mezui-Me-Ndong, Jérôme; Ndong-Atome, Guy Roger; Bisvigou, Ulrick; Mazier, Dominique; Bisser, Sylvie
2007-01-01
Background: Plasmodium falciparum causes severe clinical manifestations by sequestering parasitized red blood cells (PRBC) in the microvasculature of major organs such as the brain. This sequestration results from PRBC adherence to vascular endothelial cells via erythrocyte membrane protein 1, a variant parasite surface antigen. Objective: To determine whether P. falciparum multiple genotype infection (MGI) is associated with stronger PRBC cytoadherence and greater clinical severity. Methods: Nested polymerase chain reaction was used to genotype P. falciparum isolates from symptomatic children and to distinguish between single genotype infection (SGI) and MGI. PRBC cytoadhesion was studied with cultured human lung endothelial cells. Results: Analysis of two highly polymorphic regions of the merozoite surface antigen (MSP)-1 and MSP-2 genes and a dimorphic region of the erythrocyte binding antigen-175 gene showed that 21.4% and 78.6% of the 42 children had SGI and MGI, respectively. It also showed that 37 (89%) of the 42 PRBC samples expressed MSP-1 allelic family K1. Cytoadherence values ranged from 58 to 1811 PRBC/mm2 of human lung endothelial cells monolayer in SGI and from 5 to 5744 PRBC/mm2 in MGI. MGI was not associated with higher cytoadherence values or with more severe malaria. Conclusions: These results suggested that infection of the same individual by multiple clones of P. falciparum does not significantly influence PRBC cytoadherence or disease severity and confirmed the predominance of the MSP-1 K1 genotype in southeastern Gabon. PMID:17607045
IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...
EPA's assessment of the noncancer health effects and carcinogenic potential of Beryllium was added to the IRIS database in 1998. The IRIS program is updating the IRIS assessment for Beryllium. This update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for Beryllium will consist of an updated Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of Beryllium (RfD and RfC) and a cancer assessment. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency and Interagency review, and external scientific peer review. The final products will constitute the Agency's opinion on the toxicity of Beryllium. Beryllium is a light alkaline earth metal used in metal alloys and in high-performance products in the metallurgical, aerospace, and nuclear industries. According to the Superfund database, beryllium is found in over 300 NPL sites
Seminal Plasma Proteins as Androgen Receptor Coregulators Promote Prostate Cancer Growth
2014-10-01
structural proteins in human semen containing a high concentration of Zn2+, and their physiological functions have been well characterized...Specifically, semenogelins, upon binding to Zn2+, play an important role in gel-like formation of the semen [1]. After ejaculation, these proteins are degraded...determined whether SgI regulated the expression of PSA, an androgen- inducible AR target and also known to proteolyze SgI in semen [1,2], in prostate
Specialised sympathetic neuroeffector associations in immature rat iris arterioles
SANDOW, SHAUN L.; HILL, CARYL E.
1999-01-01
Sympathetic nerve-mediated vasoconstriction in iris arterioles of mature rats occurs via the activation of α1B-adrenoceptors alone, while in immature rat iris arterioles, vasoconstriction occurs via activation of both α1- and α2-adrenoceptors. In mature rats the vast majority of sympathetic varicosities form close neuroeffector junctions. Serial section electron microscopy of 14 d iris arterioles has been used to determine whether restriction in physiological receptor types with age may result from the establishment of these close neuroeffector junctions. Ninety varicosities which lay within 4 μm of arteriolar smooth muscle were followed for their entire length. Varicosities rarely contained dense cored vesicles even after treatment with 5-hydroxydopamine. 47% of varicosities formed close associations with muscle cells and 88% formed close associations with muscle cells or melanocytes. Varicosities in bundles were as likely as single varicosities to form close associations with vascular smooth muscle cells, although the distribution of synaptic vesicles in single varicosities did not show the asymmetric accumulation towards the smooth muscle cells seen in the varicosities in bundles which were frequently clustered together. We conclude that restriction of physiological receptor types during development does not appear to correlate with the establishment of close neuroeffector junctions, although changes in presynaptic structures may contribute to the refinement of postsynaptic responses. PMID:10529061
NASA Astrophysics Data System (ADS)
Dupuy, Pascal; Harter, Jean
1995-09-01
Iris is a modular infrared thermal image developed by SAGEM since 1988, based on a 288 by 4 IRCCD detector. The first section of the presentation gives a description of the different modules of the IRIS thermal imager and their evolution in recent years. The second section covers the description of the major evolution, namely the integrated detector cooler assembly (IDCA), using a SOFRADIR 288 by 4 detector and a SAGEM microcooler, now integrated in the IRIS thermal imagers. The third section gives the description of two functions integrated in the IRIS thermal imager: (1) image enhancement, using a digital convolution filter, and (2) automatic hot points detection and tracking, offering an assistance to surveillance and automatic detection. The last section presents several programs for navy, air forces, and land applications for which IRIS has already been selected and achieved.
Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan
2016-01-01
Aim: To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Settings and Design: Retrospective, noncomparable consecutive case series study. Materials and Methods: Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Results: Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1–4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Conclusions: Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support. PMID:27146932
A Real-Time Assimilative Model for IRI
NASA Astrophysics Data System (ADS)
Reinisch, B. W.; Huang, X.; Galkin, I.; Bilitza, D.
2012-04-01
Ionospheric models are mostly unable to correctly predict the effects of space weather events and atmospheric disturbances on the ionosphere. This is especially true for the International Reference Ionosphere (IRI) which by design is a monthly median (climatological) model [Bilitza et al., 2011]. We propose a Real-Time Assimilative Model "RTAM" for IRI that is ingesting, initially, the available real-time Digisonde GIRO [Reinisch and Galkin, 2011] data streams: foF2/hmF2, MUF3000F2, foF1/hmF1, and foE/hmF2 [Galkin et al., 2011]. Deviations of these characteristics, especially foF2, from the monthly median values are the main cause for errors in the IRI model prediction. The assimilative modeling will provide a high-resolution, global picture of the ionospheric response to various short-term events observed during periods of storm activity or the impact of gravity waves coupling the ionosphere to the lower atmosphere, including timelines of the vertical restructuring of the plasma distribution. GIRO currently provides reliable real-time data from 42 stations at a cadence of 15 min or 5 min. The number of stations is rapidly growing and is likely to soon be complemented by satellite borne topside sounders. IRI uses the characteristics predictions based on CCIR/URSI maps of coefficients. The diurnal variation of the foF2 characteristic, for example, is presented by the Fourier series Σ6 foF 2(T, φ,λ,χ) = a0(φ,λ,χ)+ (an(φ,λ,χ)cosnT + bn(φ,λ,χ)sin nT), n=1 where T is Universal Time in hours, and φ, λ, χ are the geographic latitude, longitude, and modified dip latitude, respectively. The coefficients an are in turn expanded as functions φ, λ, χ resulting in a set of 24 global maps of 988 coefficients each, one for each month of the year and for two levels of solar activity, R12=10 and 100, where R12 is the 12-month running-mean of the monthly sunspot number Rm (2*12*988 = 23,712 coefficients in all) [ITU-R, 2011]. For a given point in time, 988 coefficients need to be adjusted such that the new foF2 map reproduces the 42 values measured at that time by the GIRO network and smoothly transforms the original model map. This totally underdetermined task has been approached by using the mathematical tool of Linear Programming; preliminary results are presented. The technique can also be applied for regional modeling. Retroactive RTAM processing of the maps for an entire solar cycle will result in improved CCIR and URSI maps of the F2 peak characteristics, i.e., in an improved IRI electron density model. Bilitza D., L.-A. McKinnell, B. Reinisch, and T. Fuller-Rowell (2011), The International Reference Ionosphere (IRI) today and in the future, J. Geodesy, 85:909-920, DOI 10.1007/s00190-010-0427-x Galkin, I. A., B. W. Reinisch, , X. Huang, and D. Bilitza, Assimilation of GIRO data in Real-Time IRI: Progress Report, International Reference Ionosphere Workshop IRI-2011, Hermanus, South Africa, October 10-14, 2011. ITU-R, Information Document on Ionospheric Mapping, Working Party 3L (3L/80 Ann. 4, 3L/86. 3L/95), Oct. 2011. Reinisch, B. W. and I. A. Galkin (2011), Global Ionospheric Radio Observatory (GIRO), Earth, Planets and Space, 63(4), 377-381.
Manosuthi, Weerawat; Van Tieu, Hong; Mankatitham, Wiroj; Lueangniyomkul, Aroon; Ananworanich, Jintanat; Avihingsanon, Anchalee; Siangphoe, Umaporn; Klongugkara, Sukonsri; Likanonsakul, Sirirat; Thawornwan, Unchana; Suntisuklappon, Bussakorn; Sungkanuparph, Somnuek
2009-11-27
The International Network for the Study of HIV-associated IRIS (INSHI) recently published criteria for tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) diagnosis. The performance of this definition and clinical manifestations of TB-IRIS were studied. Antiretroviral therapy-naive HIV/TB Thai patients receiving antituberculous therapy were enrolled during 2006-2007 and prospectively followed through 24 weeks of antiretroviral therapy. Patients were defined as having paradoxical TB-IRIS if they fulfilled the 'study definition' by French 2004 and were confirmed by an external reviewer. All were later compared by the classification according to 'INSHI-2008'. For the 126 patients, median baseline CD4 cell count was 43 cells/microl and HIV-1 RNA was 5.9 log(10) Y copies/ml. Seventy-three (58%) had extrapulmonary/disseminated TB. Twenty-two (18%) and 21 (17%) fulfilled TB-IRIS criteria according to the study definition and INSHI-2008 definition, respectively. Two (2%) were diagnosed by study definition only and one (1%) by INSHI-2008 definition only. Twenty (16%) were concordantly diagnosed by both definitions and 103 (82%) were consistently negative. Eighteen (82%) had worsening of a preexisting site, whereas four (18%) had TB-IRIS in a new location. Lymph node enlargement (73%) and fever (59%) were common in TB-IRIS. Sensitivity and specificity of INSHI-2008 was 91% (95% confidence interval, 72-98%) and 99% (95% confidence interval, 95-99.8%), respectively. Positive predictive value was 95% and negative predictive value was 98%. By multivariate analysis, factors predicting TB-IRIS were extrapulmonary TB (odds ratio, 8.63) and disseminated TB (odds ratio, 4.17). There was high concordance between the INSHI-2008 and French 2004 definition for TB-IRIS diagnosis in HIV/TB patients with relatively high rate of paradoxical TB-IRIS. This suggests that lack of HIV-1 RNA and CD4 cell count monitoring does not impede the ability to diagnose TB-IRIS.
Antigen-Specific Interferon-Gamma Responses and Innate Cytokine Balance in TB-IRIS
Goovaerts, Odin; Jennes, Wim; Massinga-Loembé, Marguerite; Ceulemans, Ann; Worodria, William; Mayanja-Kizza, Harriet; Colebunders, Robert; Kestens, Luc
2014-01-01
Background Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) remains a poorly understood complication in HIV-TB patients receiving antiretroviral therapy (ART). TB-IRIS could be associated with an exaggerated immune response to TB-antigens. We compared the recovery of IFNγ responses to recall and TB-antigens and explored in vitro innate cytokine production in TB-IRIS patients. Methods In a prospective cohort study of HIV-TB co-infected patients treated for TB before ART initiation, we compared 18 patients who developed TB-IRIS with 18 non-IRIS controls matched for age, sex and CD4 count. We analyzed IFNγ ELISpot responses to CMV, influenza, TB and LPS before ART and during TB-IRIS. CMV and LPS stimulated ELISpot supernatants were subsequently evaluated for production of IL-12p70, IL-6, TNFα and IL-10 by Luminex. Results Before ART, all responses were similar between TB-IRIS patients and non-IRIS controls. During TB-IRIS, IFNγ responses to TB and influenza antigens were comparable between TB-IRIS patients and non-IRIS controls, but responses to CMV and LPS remained significantly lower in TB-IRIS patients. Production of innate cytokines was similar between TB-IRIS patients and non-IRIS controls. However, upon LPS stimulation, IL-6/IL-10 and TNFα/IL-10 ratios were increased in TB-IRIS patients compared to non-IRIS controls. Conclusion TB-IRIS patients did not display excessive IFNγ responses to TB-antigens. In contrast, the reconstitution of CMV and LPS responses was delayed in the TB-IRIS group. For LPS, this was linked with a pro-inflammatory shift in the innate cytokine balance. These data are in support of a prominent role of the innate immune system in TB-IRIS. PMID:25415590
NASA Astrophysics Data System (ADS)
Tomioka, Y.; Ito, T.; Sawa, A.
2018-01-01
For half-doped manganese oxides that have a perovskite structure, R E1 -xA ExMn O3 (x =0.5 ) (RE and AE are rare-earth and alkaline-earth elements, respectively), the phase competition (stability) between the antiferromagnetic charge- or orbital-ordered insulator (CO/OO AFI), ferromagnetic metal (FM), layered (A-type) antiferromagnetic phase [AF(A)], and spin-glass-like insulator (SGI), have been studied using single crystals prepared by the floating zone method. The CO/OO AFI, FM, AF(A), and SGI are displayed on the plane of the disorder (the variance of the RE and AE cations) versus the effective one-electron bandwidth (the averaged ionic radius of the RE and AE). In the plane of the disorder versus the effective one-electron bandwidth, similar to the phase diagram of R E1 -xA ExMn O3 (x =0.45 ), the CO/OO AFI, FM, and SGI dominate at the lower-left, right, and upper regions, respectively. However, the CO/OO AFI for x =0.5 is more stable than that for x =0.45 , and it expands to the plane points that correspond to the R E0.5S r0.5Mn O3 (R E =Nd and Sm) specimens as the hole concentration is commensurate with the ordering of M n3 + /M n4 + with a ratio of 1/1. The y -dependent electronic phases for R E0.5(Sr1-yB ay ) 0.5Mn O3 (0 ≤y ≤0.5 ) (R E =Sm , N d0.5S m0.5 , Nd, and Pr) show that the AF(A) intervenes between the CO/OO AFI and FM. Besides the region around (La1-yP ry ) 0.5S r0.5Mn O3 (0 ≤y ≤1 ) that has a smaller disorder, the AF(A) also exists at the regions around R E0.5(Sr1-yB ay ) 0.5Mn O3 (0
Prostaglandin ethanolamides (prostamides): in vitro pharmacology and metabolism.
Matias, I; Chen, J; De Petrocellis, L; Bisogno, T; Ligresti, A; Fezza, F; Krauss, A H-P; Shi, L; Protzman, C E; Li, C; Liang, Y; Nieves, A L; Kedzie, K M; Burk, R M; Di Marzo, V; Woodward, D F
2004-05-01
We investigated whether prostaglandin ethanolamides (prostamides) E(2), F(2alpha), and D(2) exert some of their effects by 1) activating prostanoid receptors either per se or after conversion into the corresponding prostaglandins; 2) interacting with proteins for the inactivation of the endocannabinoid N-arachidonoylethanolamide (AEA), for example fatty acid amide hydrolase (FAAH), thereby enhancing AEA endogenous levels; or 3) activating the vanilloid receptor type-1 (TRPV1). Prostamides potently stimulated cat iris contraction with potency approaching that of the corresponding prostaglandins. However, prostamides D(2), E(2), and F(2alpha) exhibited no meaningful interaction with the cat recombinant FP receptor, nor with human recombinant DP, EP(1-4), FP, IP, and TP prostanoid receptors. Prostamide F(2alpha) was also very weak or inactive in a panel of bioassays specific for the various prostanoid receptors. None of the prostamides inhibited AEA enzymatic hydrolysis by FAAH in cell homogenates, or AEA cellular uptake in intact cells. Furthermore, less than 3% of the compounds were hydrolyzed to the corresponding prostaglandins when incubated for 4 h with homogenates of rat brain, lung, or liver, and cat iris or ciliary body. Very little temperature-dependent uptake of prostamides was observed after incubation with rat brain synaptosomes or RBL-2H3 cells. We suggest that prostamides' most prominent pharmacological actions are not due to transformation into prostaglandins, activation of prostanoid receptors, enhancement of AEA levels, or gating of TRPV1 receptors, but possibly to interaction with novel receptors that seem to be functional in the cat iris.
IRIS Toxicological Review of 1,4-Dioxane (Interagency ...
On September 9, 2011, the Toxicological Review of 1,4-Dioxane (with inhalation update) (External Review Draft) was posted for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments with EPA's response and the interagency science consultation draft of the IRIS Toxicological Review of 1,4-dioxane and the charge to external peer reviewers are posted on this site. The Toxicological Review of 1,4-dioxane provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to 1,4-dioxane.
New C16-noriridals and formyl-monocycloiridals from the rhizomes of Iris pseudoacorus.
Chen, Xinglong; Zhang, Xiuqiong; Geng, Changan; Li, Tianze; Chen, Jijun
2018-01-01
Four new C 16 -noriridals (1-4) and two reported C 16 -noriridals (5-6), together with two new formyl-monocycloiridals (7-8) and three known monocycloiridals (9-11) were isolated from the rhizomes of Iris pseudoacorus. Irispseudoacorins A-D (1-4) and iridojaponals A-B (5-6) were C 16 -noriridals which shared a 6/5/7 tricyclic ring system (1-2, 5-6) or 6/5 tricyclic ring system (3-4). The formyl-monocycloiridals (7-8) were detected in the crude extracts of I. pseudoacorus by LC-MS analysis which suggested they were originated from natural sources rather than artificial products during the isolation. Their structures were determined by UV, IR, extensive NMR spectra and X-ray diffraction analyses. The known monocycloiridals 9-10 displayed pronounced cytotoxic effects against five human tumor cell lines. The IC 50 values of 9 were ranging from 12.63 to 24.69μM. Copyright © 2017 Elsevier B.V. All rights reserved.
IRIS Toxicological Review of Thallium and Compounds ...
Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certain tumors. EPA's assessment of noncancer health effects and carcinogenic potential of thallium compounds was last prepared and added to the IRIS database between 1988 and 1990. The IRIS program is preparing an assessment that will incorporate current health effects information available for thallium and compounds, and current risk assessment methods. The IRIS assessment for thallium compounds will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity in humans and experimental systems. The assessment will present reference values for the noncancer effects of thallium compounds (RfD and Rfc), and a cancer assessment. The Toxicological Review and IRIS Summary have been subject to Agency review, Interagency review, and external scientific peer review. The final product will reflect the Agency opinion on the overall toxicity of thallium and compounds. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for thallium and compounds. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effec
NASA Technical Reports Server (NTRS)
Hom, K. W.
1994-01-01
The EM-ANIMATE program is a specialized visualization program that displays and animates the near-field and surface-current solutions obtained from an electromagnetics program, in particular, that from MOM3D (LAR-15074). The EM-ANIMATE program is windows based and contains a user-friendly, graphical interface for setting viewing options, case selection, file manipulation, etc. EM-ANIMATE displays the field and surface-current magnitude as smooth shaded color fields (color contours) ranging from a minimum contour value to a maximum contour value for the fields and surface currents. The program can display either the total electric field or the scattered electric field in either time-harmonic animation mode or in the root mean square (RMS) average mode. The default setting is initially set to the minimum and maximum values within the field and surface current data and can be optionally set by the user. The field and surface-current value are animated by calculating and viewing the solution at user selectable radian time increments between 0 and 2pi. The surface currents can also be displayed in either time-harmonic animation mode or in RMS average mode. In RMS mode, the color contours do not vary with time, but show the constant time averaged field and surface-current magnitude solution. The electric field and surface-current directions can be displayed as scaled vector arrows which have a length proportional to the magnitude at each field grid point or surface node point. These vector properties can be viewed separately or concurrently with the field or surface-current magnitudes. Animation speed is improved by turning off the display of the vector arrows. In RMS modes, the direction vectors are still displayed as varying with time since the time averaged direction vectors would be zero length vectors. Other surface properties can optionally be viewed. These include the surface grid, the resistance value assigned to each element of the grid, and the power dissipation of each element which has an assigned resistance value. The EM-ANIMATE program will accept up to 10 different surface current cases each consisting of up to 20,000 node points and 10,000 triangle definitions and will animate one of these cases. The capability is used to compare surface-current distribution due to various initial excitation directions or electric field orientations. The program can accept up to 50 planes of field data consisting of a grid of 100 by 100 field points. These planes of data are user selectable and can be viewed individually or concurrently. With these preset limits, the program requires 55 megabytes of core memory to run. These limits can be changed in the header files to accommodate the available core memory of an individual workstation. An estimate of memory required can be made as follows: approximate memory in bytes equals (number of nodes times number of surfaces times 14 variables times bytes per word, typically 4 bytes per floating point) plus (number of field planes times number of nodes per plane times 21 variables times bytes per word). This gives the approximate memory size required to store the field and surface-current data. The total memory size is approximately 400,000 bytes plus the data memory size. The animation calculations are performed in real time at any user set time step. For Silicon Graphics Workstations that have multiple processors, this program has been optimized to perform these calculations on multiple processors to increase animation rates. The optimized program uses the SGI PFA (Power FORTRAN Accelerator) library. On single processor machines, the parallelization directives are seen as comments to the program and will have no effect on compilation or execution. EM-ANIMATE is written in FORTRAN 77 for implementation on SGI IRIS workstations running IRIX 3.0 or later. A minimum of 55Mb of RAM is required for execution of this program; however, the code may be modified to accommodate the available memory of an individual workstation. For program execution, twenty-four bit, double-buffered color capability is suggested, but not required. Sample input and output files and a sample executable are provided on the distribution medium. Electronic documentation is provided in PostScript format and in the form of IRIX man pages. The standard distribution medium for EM-ANIMATE is a .25 inch streaming magnetic IRIX tape cartridge in UNIX tar format. EM-ANIMATE is also available as part of a bundled package, COS-10048 that includes MOM3D, an IRIS program that produces electromagnetic near field and surface current solutions. This program was developed in 1993.
The International Reference Ionosphere: Model Update 2016
NASA Astrophysics Data System (ADS)
Bilitza, Dieter; Altadill, David; Reinisch, Bodo; Galkin, Ivan; Shubin, Valentin; Truhlik, Vladimir
2016-04-01
The International Reference Ionosphere (IRI) is recognized as the official standard for the ionosphere (COSPAR, URSI, ISO) and is widely used for a multitude of different applications as evidenced by the many papers in science and engineering journals that acknowledge the use of IRI (e.g., about 11% of all Radio Science papers each year). One of the shortcomings of the model has been the dependence of the F2 peak height modeling on the propagation factor M(3000)F2. With the 2016 version of IRI, two new models will be introduced for hmF2 that were developed directly based on hmF2 measurements by ionosondes [Altadill et al., 2013] and by COSMIC radio occultation [Shubin, 2015], respectively. In addition IRI-2016 will include an improved representation of the ionosphere during the very low solar activities that were reached during the last solar minimum in 2008/2009. This presentation will review these and other improvements that are being implemented with the 2016 version of the IRI model. We will also discuss recent IRI workshops and their findings and results. One of the most exciting new projects is the development of the Real-Time IRI [Galkin et al., 2012]. We will discuss the current status and plans for the future. Altadill, D., S. Magdaleno, J.M. Torta, E. Blanch (2013), Global empirical models of the density peak height and of the equivalent scale height for quiet conditions, Advances in Space Research 52, 1756-1769, doi:10.1016/j.asr.2012.11.018. Galkin, I.A., B.W. Reinisch, X. Huang, and D. Bilitza (2012), Assimilation of GIRO Data into a Real-Time IRI, Radio Science, 47, RS0L07, doi:10.1029/2011RS004952. Shubin V.N. (2015), Global median model of the F2-layer peak height based on ionospheric radio-occultation and ground-based Digisonde observations, Advances in Space Research 56, 916-928, doi:10.1016/j.asr.2015.05.029.
Iris Damage Is Associated With Elevated Cytokine Levels in Aqueous Humor.
Aketa, Naohiko; Yamaguchi, Takefumi; Suzuki, Terumasa; Higa, Kazunari; Yagi-Yaguchi, Yukari; Satake, Yoshiyuki; Tsubota, Kazuo; Shimazaki, Jun
2017-05-01
To evaluate the association between iris damage and cytokine levels in the aqueous humor (AqH). A total of 201 AqH samples from 201 consecutive patients (mean age 73.7 ± 10.6) were collected at the beginning of corneal transplantation or cataract surgery. Iris damage of each case was assessed from preoperative slit-lamp findings based on its severity. The subjects were classified into three groups: eyes without iris damage (126 eyes), eyes with mild iris damage (51 eyes), and eyes with severe iris damage (24 eyes). The levels of cytokines (IL-1α, IL-1β, IL-4, IL-6, IL-8, IL-10, IL-12p70, IL-13, IL-17a, interferon gamma-induced protein [IP]-10, monocyte chemotactic protein [MCP]-1, IFN-α, IFN-γ, macrophage inflammatory protein [MIP]-1α, MIP-1β, P-selectin, E-selectin, soluble intercellular adhesion molecule [sICAM]-1, TNF-α, and granulocyte-macrophage colony-stimulating factor [GM-CSF]) in AqH were measured by multiplex beads immunoassay. The levels of aqueous protein, IL-1α, IL-1β, IL-4, IL-6, IL-8, IL-10, IL-17A, MCP-1, TNF-α, E-selectin, P-selectin, and sICAM-1 in eyes with mild and severe iris damage were higher than in those without iris damage (P < 0.033). Multivariate analyses of clinical factors revealed that iris damage was associated with the history of complicated glaucoma, and the number of previous intraocular surgeries. The levels of AqH IL-6, IL-8, IL-13, MIP-1α, TNF-α, and sICAM-1 were significantly elevated in eyes with mild and severe iris damage in phakic eyes, and the levels of AqH IL-8 and sICAM-1 were significantly elevated in eyes with severe iris damage in pseudophakic eyes, compared with the eyes without iris damage (P < 0.045). Iris damage was associated with the elevation in the levels of aqueous protein and cytokines.
IRIS Toxicological Review of Tetrachloroethylene ...
EPA conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of tetrachloroethylene that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and appropriately in derivation of the toxicological characterization and dose-response assessments. This draft health assessment addresses both non-cancer and cancer human health effects that may result from chronic exposure to tetrachloroethylene (also called Perchloroethylene or Perc) . This is an update of an existing assessment posted on IRIS in 1988. This draft Toxicological Review includes a chronic Reference Concentration (RfC) and carcinogenicity assessment, which are not currently available on IRIS, as well as an update of the 1988 IRIS Reference Dose (RfD). Tetrachloroethylene is a chemical solvent that is widely used for dry cleaning of fabrics, metal degreasing, and in making some consumer products and other chemicals.
Hong, Ji Wook; Yun, Sung-Cheol; Sung, Kyung Rim; Lee, Jong Eun
2016-06-01
To compare the clinical and anterior segment anatomical features in primary angle closure sub-groups based on configurations of iris root insertion. Primary angle closure patients were imaged using anterior segment optical coherence tomography. Anterior chamber depth, iris curvature, iris thickness (IT) at the scleral spur and 500, 750, and 1,500 µm from the scleral spur (IT0, IT500, IT750, and IT1500), lens vault, iris area, angle opening distance (AOD500), angle recess area (ARA750), and trabecular iris space area (TISA750) were measured. Iris root insertion was categorized into a non-basal insertion group (NBG) and basal insertion group (BG). In total, 43 eyes of 39 participants belonged to the NBG and 89 eyes of 53 participants to the BG. The mean age of participants was greater in the NBG than the BG (62.7 ± 5.7 vs. 59.8 ± 7.3 years, p = 0.043), and the baseline intraocular pressure was higher in the BG than the NBG (16.4 ± 4.4 vs. 14.9 ± 3.3 mmHg, p = 0.037). The BG showed a greater IT0 (0.265 ± 0.04 vs. 0.214 ± 0.03 mm, p < 0.001) and iris area (1.59 ± 0.24 vs. 1.52 ± 0.27 mm(2), p = 0.045), lower ARA750 (0.112 ± 0.08 vs. 0.154 ± 0.08 mm(2), p = 0.017) and AOD500 (0.165 ± 0.07 vs. 0.202 ± 0.08 mm, p = 0.014) compared to the NBG. The BG had a narrower anterior chamber angle, thicker peripheral iris, and higher pretreatment intraocular pressure.
Fournier, Anna; Martin-Blondel, Guillaume; Lechapt-Zalcman, Emmanuèle; Dina, Julia; Kazemi, Apolline; Verdon, Renaud; Mortier, Emmanuel; de La Blanchardière, Arnaud
2017-01-01
Incidence of progressive multifocal leukoencephalopathy (PML) in HIV-infected patients has declined in the combined antiretroviral therapy (cART) era although a growing number of acquired immunodeficiency syndrome (AIDS)-related PML-immune reconstitution inflammatory syndromes (PML-IRIS) have been published during the same period. Therapeutic management of PML-IRIS is not consensual and mainly relies on corticosteroids. Our main aim was, in addition to provide a thoughtful analysis of published PML-IRIS cases, to assess the benefit of corticosteroids in the management of PML-IRIS, focusing on confirmed cases. We performed a literature review of the 46 confirmed cases of PML-IRIS cases occurring in HIV-infected patients from 1998 to September 2016 (21 unmasking and 25 paradoxical PML-IRIS). AIDS-related PML-IRIS patients were mostly men (sex ratio 4/1) with a median age of 40.5 years (range 12-66). Median CD4 T cell count before cART and at PML-IRIS onset was 45/μl (0-301) and 101/μl (20-610), respectively. After cART initiation, PML-IRIS occurred within a median timescale of 38 days (18-120). Clinical signs were motor deficits (69%), speech disorders (36%), cognitive disorders (33%), cerebellar ataxia (28%), and visual disturbances (23%). Brain MRI revealed hyperintense areas on T2-weighted sequences and FLAIR images (76%) and suggestive contrast enhancement (87%). PCR for John Cunningham virus (JCV) in cerebrospinal fluid (CSF) was positive in only 84% of cases; however, when performed, brain biopsy confirmed diagnosis of PML in 90% of cases and demonstrated histological signs of IRIS in 95% of cases. Clinical worsening related to PML-IRIS and leading to death was observed in 28% of cases. Corticosteroids were prescribed in 63% of cases and maraviroc in one case. Statistical analysis failed to demonstrate significant benefit from steroid treatment, despite spectacular improvement in certain cases. Diagnosis of PML-IRIS should be considered in HIV-infected patients with worsening neurological symptoms after initiation or resumption of effective cART, independently of CD4 cell count prior to cART. If PCR for JCV is negative in CSF, brain biopsy should be discussed. Only large multicentric randomized trials could potentially demonstrate the possible efficacy of corticosteroids and/or CCR5 antagonists in the management of PML-IRIS.
Fournier, Anna; Martin-Blondel, Guillaume; Lechapt-Zalcman, Emmanuèle; Dina, Julia; Kazemi, Apolline; Verdon, Renaud; Mortier, Emmanuel; de La Blanchardière, Arnaud
2017-01-01
Incidence of progressive multifocal leukoencephalopathy (PML) in HIV-infected patients has declined in the combined antiretroviral therapy (cART) era although a growing number of acquired immunodeficiency syndrome (AIDS)-related PML-immune reconstitution inflammatory syndromes (PML-IRIS) have been published during the same period. Therapeutic management of PML-IRIS is not consensual and mainly relies on corticosteroids. Our main aim was, in addition to provide a thoughtful analysis of published PML-IRIS cases, to assess the benefit of corticosteroids in the management of PML-IRIS, focusing on confirmed cases. We performed a literature review of the 46 confirmed cases of PML-IRIS cases occurring in HIV-infected patients from 1998 to September 2016 (21 unmasking and 25 paradoxical PML-IRIS). AIDS-related PML-IRIS patients were mostly men (sex ratio 4/1) with a median age of 40.5 years (range 12–66). Median CD4 T cell count before cART and at PML-IRIS onset was 45/μl (0–301) and 101/μl (20–610), respectively. After cART initiation, PML-IRIS occurred within a median timescale of 38 days (18–120). Clinical signs were motor deficits (69%), speech disorders (36%), cognitive disorders (33%), cerebellar ataxia (28%), and visual disturbances (23%). Brain MRI revealed hyperintense areas on T2-weighted sequences and FLAIR images (76%) and suggestive contrast enhancement (87%). PCR for John Cunningham virus (JCV) in cerebrospinal fluid (CSF) was positive in only 84% of cases; however, when performed, brain biopsy confirmed diagnosis of PML in 90% of cases and demonstrated histological signs of IRIS in 95% of cases. Clinical worsening related to PML-IRIS and leading to death was observed in 28% of cases. Corticosteroids were prescribed in 63% of cases and maraviroc in one case. Statistical analysis failed to demonstrate significant benefit from steroid treatment, despite spectacular improvement in certain cases. Diagnosis of PML-IRIS should be considered in HIV-infected patients with worsening neurological symptoms after initiation or resumption of effective cART, independently of CD4 cell count prior to cART. If PCR for JCV is negative in CSF, brain biopsy should be discussed. Only large multicentric randomized trials could potentially demonstrate the possible efficacy of corticosteroids and/or CCR5 antagonists in the management of PML-IRIS. PMID:28588577
Proton beam radiotherapy of iris melanoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damato, Bertil; Kacperek, Andrzej; Chopra, Mona
2005-09-01
Purpose: To report on outcomes after proton beam radiotherapy of iris melanoma. Methods and Materials: Between 1993 and 2004, 88 patients with iris melanoma received proton beam radiotherapy, with 53.1 Gy in 4 fractions. Results: The patients had a mean age of 52 years and a median follow-up of 2.7 years. The tumors had a median diameter of 4.3 mm, involving more than 2 clock hours of iris in 32% of patients and more than 2 hours of angle in 27%. The ciliary body was involved in 20%. Cataract was present in 13 patients before treatment and subsequently developed inmore » another 18. Cataract had a 4-year rate of 63% and by Cox analysis was related to age (p = 0.05), initial visual loss (p < 0.0001), iris involvement (p < 0.0001), and tumor thickness (p < 0.0001). Glaucoma was present before treatment in 13 patients and developed after treatment in another 3. Three eyes were enucleated, all because of recurrence, which had an actuarial 4-year rate of 3.3% (95% CI 0-8.0%). Conclusions: Proton beam radiotherapy of iris melanoma is well tolerated, the main problems being radiation-cataract, which was treatable, and preexisting glaucoma, which in several patients was difficult to control.« less
Potential roles for BMP and Pax genes in the development of iris smooth muscle.
Jensen, Abbie M
2005-02-01
The embryonic optic cup generates four types of tissue: neural retina, pigmented epithelium, ciliary epithelium, and iris smooth muscle. Remarkably little attention has focused on the development of the iris smooth muscle since Lewis ([1903] J. Am. Anat. 2:405-416) described its origins from the anterior rim of the optic cup neuroepithelium. As an initial step toward understanding iris smooth muscle development, I first determined the spatial and temporal pattern of the development of the iris smooth muscle in the chick by using the HNK1 antibody, which labels developing iris smooth muscle. HNK1 labeling shows that iris smooth muscle development is correlated in time and space with the development of the ciliary epithelial folds. Second, because neural crest is the only other neural tissue that has been shown to generate smooth muscle (Le Lievre and Le Douarin [1975] J. Embryo. Exp. Morphol. 34:125-154), I sought to determine whether iris smooth muscle development shares similarities with neural crest development. Two members of the BMP superfamily, BMP4 and BMP7, which may regulate neural crest development, are highly expressed by cells at the site of iris smooth muscle generation. Third, because humans and mice that are heterozygous for Pax6 mutations have no irides (Hill et al. [1991] Nature 354:522-525; Hanson et al. [1994] Nat. Genet. 6:168-173), I determined the expression of Pax6. I also examined the expression of Pax3 in the developing anterior optic cup. The developing iris smooth muscle coexpresses Pax6 and Pax3. I suggest that some of the eye defects caused by mutations in Pax6, BMP4, and BMP7 may be due to abnormal iris smooth muscle. Copyright 2004 Wiley-Liss, Inc.
Porter, Brian O.; Chandrasekhar, Chockalingam; Venkatesan, Perumal; Menon, Pradeep A.; Subramanian, Sudha; Anbalagan, Selvaraj; Bhavani, Kannabiran P.; Sekar, Sathiyavelu; Padmapriyadarshini, Chandrasekaran; Kumar, Satagopan; Ravichandran, Narayanan; Raja, Krishnaraj; Bhanu, Kesavamurthy; Mahilmaran, Ayyamperumal; Sekar, Lakshmanan; Sher, Alan; Sereti, Irini; Swaminathan, Soumya
2013-01-01
Background The incidence, manifestations, outcome and clinical predictors of paradoxical TB-IRIS in patients with HIV and culture confirmed pulmonary tuberculosis (PTB) in India have not been studied prospectively. Methods HIV+ patients with culture confirmed PTB started on anti-tuberculosis therapy (ATT) were followed prospectively after anti-retroviral therapy (ART) initiation. Established criteria for IRIS diagnosis were used including decline in plasma HIV RNA at IRIS event. Pre-ART plasma levels of interleukin (IL)-6 and C-reactive protein (CRP) were measured. Univariate and multivariate logistic regression models were used to evaluate associations between baseline variables and IRIS. Results Of 57 patients enrolled, 48 had complete follow up data. Median ATT-ART interval was 28 days (interquartile range, IQR 14–47). IRIS events occurred in 26 patients (54.2%) at a median of 11 days (IQR: 7–16) after ART initiation. Corticosteroids were required for treatment of most IRIS events that resolved within a median of 13 days (IQR: 9–23). Two patients died due to CNS TB-IRIS. Lower CD4+ T-cell counts, higher plasma HIV RNA levels, lower CD4/CD8 ratio, lower hemoglobin, shorter ATT to ART interval, extra-pulmonary or miliary TB and higher plasma IL-6 and CRP levels at baseline were associated with paradoxical TB-IRIS in the univariate analysis. Shorter ATT to ART interval, lower hemoglobin and higher IL-6 and CRP levels remained significant in the multivariate analysis. Conclusion Paradoxical TB–IRIS frequently complicates HIV-TB therapy in India. IL-6 and CRP may assist in predicting IRIS events and serve as potential targets for immune interventions. PMID:23691062
NASA Astrophysics Data System (ADS)
He, Fei; Liu, Yuanning; Zhu, Xiaodong; Huang, Chun; Han, Ye; Dong, Hongxing
2014-12-01
Gabor descriptors have been widely used in iris texture representations. However, fixed basic Gabor functions cannot match the changing nature of diverse iris datasets. Furthermore, a single form of iris feature cannot overcome difficulties in iris recognition, such as illumination variations, environmental conditions, and device variations. This paper provides multiple local feature representations and their fusion scheme based on a support vector regression (SVR) model for iris recognition using optimized Gabor filters. In our iris system, a particle swarm optimization (PSO)- and a Boolean particle swarm optimization (BPSO)-based algorithm is proposed to provide suitable Gabor filters for each involved test dataset without predefinition or manual modulation. Several comparative experiments on JLUBR-IRIS, CASIA-I, and CASIA-V4-Interval iris datasets are conducted, and the results show that our work can generate improved local Gabor features by using optimized Gabor filters for each dataset. In addition, our SVR fusion strategy may make full use of their discriminative ability to improve accuracy and reliability. Other comparative experiments show that our approach may outperform other popular iris systems.
Integrated Risk Information System (IRIS)
2,4,5 - Trichlorophenol ; CASRN 95 - 95 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcino
Use of epidemiologic data in Integrated Risk Information System (IRIS) assessments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Persad, Amanda S.; Cooper, Glinda S.
2008-11-15
In human health risk assessment, information from epidemiologic studies is typically utilized in the hazard identification step of the risk assessment paradigm. However, in the assessment of many chemicals by the Integrated Risk Information System (IRIS), epidemiologic data, both observational and experimental, have also been used in the derivation of toxicological risk estimates (i.e., reference doses [RfD], reference concentrations [RfC], oral cancer slope factors [CSF] and inhalation unit risks [IUR]). Of the 545 health assessments posted on the IRIS database as of June 2007, 44 assessments derived non-cancer or cancer risk estimates based on human data. RfD and RfC calculationsmore » were based on a spectrum of endpoints from changes in enzyme activity to specific neurological or dermal effects. There are 12 assessments with IURs based on human data, two assessments that extrapolated human inhalation data to derive CSFs and one that used human data to directly derive a CSF. Lung or respiratory cancer is the most common endpoint for cancer assessments based on human data. To date, only one chemical, benzene, has utilized human data for derivation of all three quantitative risk estimates (i.e., RfC, RfD, and dose-response modeling for cancer assessment). Through examples from the IRIS database, this paper will demonstrate how epidemiologic data have been used in IRIS assessments for both adding to the body of evidence in the hazard identification process and in the quantification of risk estimates in the dose-response component of the risk assessment paradigm.« less
2,2\\',4,4\\'-Tetrabromodiphenyl ether (BDE-47)
Integrated Risk Information System (IRIS)
EPA / 635 / R - 07 / 005F www.epa.gov / iris TOXICOLOGICAL REVIEW OF 2,2 ' , 4,4 ' - TETRABROMODIPHENYL ETHER ( BDE - 47 ) ( CAS No . 5436 - 43 - 1 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) June 2008 U.S . Environmental Protection Agency Was
4,4\\'-Methylene bis(N,N\\'-dimethyl)aniline
Integrated Risk Information System (IRIS)
4,4 ' - Methylene bis ( N , N ' - dimethyl ) aniline ; CASRN 101 - 61 - 1 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Haz
Light entrainment of the murine intraocular pressure circadian rhythm utilizes non-local mechanisms.
Tsuchiya, Shunsuke; Buhr, Ethan D; Higashide, Tomomi; Sugiyama, Kazuhisa; Van Gelder, Russell N
2017-01-01
Intraocular pressure (IOP) is known to have a strong circadian rhythm, yet how light/dark cycles entrain this rhythm is unknown. The purpose of this study was to assess whether, like the retina, the mammalian ciliary body and IOP clocks have an intrinsic ability to entrain to light/dark cycles. Iris-ciliary body complexes were obtained from period2:luciferase (PER2::LUC) mice and cultured to measure bioluminescence rhythmicity. Pairs of the iris-ciliary body complex were exposed to antiphasic 9:15 h light/dark cycle in vitro. After 4 days of exposure to light/dark cycles, bioluminescence was recorded to establish their circadian phases. In addition, pairs of the iris-ciliary body complex co-cultured with the retinas or corneas of wild-type mice were also investigated. The IOP circadian changes of free-running Opn4-/-;rd1/rd1 mice whose behavior was antiphasic to wild-type were measured by a rebound tonometry, and compared with wild-type mice. Opn3, Opn4, and Opn5 mRNA expression in the iris-ciliary body were analyzed using RT-PCR. The iris/ciliary body complex expressed Opn3, Opn4, and Opn5 mRNA; however, unlike in retina and cornea, neither the iris-CB complex nor the co-cultured complex was directly entrained by light-dark cycle in vitro. The diurnal IOP change of Opn4-/-;rd1/rd1 mice showed an antiphasic pattern to wild-type mice and their rhythms followed the whole-animal behavioral rhythm. Despite expressing mRNA for several non-visual opsins, circadian rhythms of the iris-ciliary body complex of mice do not entrain directly to light-dark cycles ex vivo. Unlike retina, the iris/ciliary body clocks of blind mice remain synchronized to the organismal behavioral rhythm rather than local light-dark cycles. These results suggest that IOP rhythm entrainment is mediated by a systemic rather than local signal in mice.
Light entrainment of the murine intraocular pressure circadian rhythm utilizes non-local mechanisms
Tsuchiya, Shunsuke; Buhr, Ethan D.; Higashide, Tomomi; Sugiyama, Kazuhisa
2017-01-01
Purpose Intraocular pressure (IOP) is known to have a strong circadian rhythm, yet how light/dark cycles entrain this rhythm is unknown. The purpose of this study was to assess whether, like the retina, the mammalian ciliary body and IOP clocks have an intrinsic ability to entrain to light/dark cycles. Methods Iris-ciliary body complexes were obtained from period2:luciferase (PER2::LUC) mice and cultured to measure bioluminescence rhythmicity. Pairs of the iris-ciliary body complex were exposed to antiphasic 9:15 h light/dark cycle in vitro. After 4 days of exposure to light/dark cycles, bioluminescence was recorded to establish their circadian phases. In addition, pairs of the iris-ciliary body complex co-cultured with the retinas or corneas of wild-type mice were also investigated. The IOP circadian changes of free-running Opn4-/-;rd1/rd1 mice whose behavior was antiphasic to wild-type were measured by a rebound tonometry, and compared with wild-type mice. Opn3, Opn4, and Opn5 mRNA expression in the iris-ciliary body were analyzed using RT-PCR. Results The iris/ciliary body complex expressed Opn3, Opn4, and Opn5 mRNA; however, unlike in retina and cornea, neither the iris-CB complex nor the co-cultured complex was directly entrained by light-dark cycle in vitro. The diurnal IOP change of Opn4-/-;rd1/rd1 mice showed an antiphasic pattern to wild-type mice and their rhythms followed the whole-animal behavioral rhythm. Conclusions Despite expressing mRNA for several non-visual opsins, circadian rhythms of the iris-ciliary body complex of mice do not entrain directly to light-dark cycles ex vivo. Unlike retina, the iris/ciliary body clocks of blind mice remain synchronized to the organismal behavioral rhythm rather than local light-dark cycles. These results suggest that IOP rhythm entrainment is mediated by a systemic rather than local signal in mice. PMID:28934261
10 Gigabit Ethernet Performance on SGI Altix and Origin Systems
NASA Technical Reports Server (NTRS)
Meyer, Andy
2005-01-01
As the state of high performance computing continues to advance, the size of datasets continue to grow, driving a need for high bandwidth data networks. family of networks. 10 Gigabit Ethernet is the latest step in the popular Ethernet We have evaluated the S2io Xframe 10 Gigabit Ethernet adapter on 512p SGI Altix systems running ProPack 3, and Origin systems running Irix 6.5.24 and 6.5.26 in our production supercomputing environment. We encountered a number of performance and stability issues, which were promptly dealt with by SGI and S2io. Using nttcp we tested TCP performance for single and multiple streams, and we tested file transfer using NFS and bbftp. We will present the results of our testing, including the effects of various tuning options on throughput and CPU utilization, and offer suggestions for configuring and tuning S2io 10 Gigabit Ethernet cards in an Altix/Linux or Origin/Irix environment.
2013-06-25
VANDENBERG AIR FORCE BASE, Calif. – At Vandenberg Air Force Base in California, NASA hosted a prelaunch mission briefing on the Interface Region Imaging Spectrograph, or IRIS, solar observatory scheduled to launch on a Pegasus XL rocket. Participating in the news conference are George Diller, NASA Public Affairs, Dr. S. Pete Worden, director of NASA's Ames Research Center in Calif., Jeffrey Newmark, IRIS Program scientist at NASA Headquarters in Washington D.C., and Alan Title, IRIS principal investigator with Lockheed Martin. Scheduled for launch from Vandenberg on June 26, 2013, IRIS will open a new window of discovery by tracing the flow of energy and plasma through the chromospheres and transition region into the sun’s corona using spectrometry and imaging. The IRIS mission will observe how solar material moves, gathers energy and heats up as it travels through a largely unexplored region of the solar atmosphere. The interface region, located between the sun's visible surface and upper atmosphere, is where most of the sun's ultraviolet emission is generated. These emissions impact the near-Earth space environment and Earth's climate. For more information, visit http://www.nasa.gov/iris Photo credit: NASA/ Daniel Casper
The IRIS-GUS Shuttle Borne Upper Stage System
NASA Technical Reports Server (NTRS)
Tooley, Craig; Houghton, Martin; Bussolino, Luigi; Connors, Paul; Broudeur, Steve (Technical Monitor)
2002-01-01
This paper describes the Italian Research Interim Stage - Gyroscopic Upper Stage (IRIS-GUS) upper stage system that will be used to launch NASA's Triana Observatory from the Space Shuttle. Triana is a pathfinder earth science mission being executed on rapid schedule and small budget, therefore the mission's upper stage solution had to be a system that could be fielded quickly at relatively low cost and risk. The building of the IRIS-GUS system wa necessary because NASA lost the capability to launch moderately sized upper stage missions fro the Space Shuttle when the PAM-D system was retired. The IRIS-GUS system restores this capability. The resulting system is a hybrid which mates the existing, flight proven IRIS (Italian Research Interim Stage) airborne support equipment to a new upper stage, the Gyroscopic Upper Stage (GUS) built by the GSFC for Triana. Although a new system, the GUS exploits flight proven hardware and design approaches in most subsystems, in some cases implementing proven design approaches with state-of-the-art electronics. This paper describes the IRIS-GUS upper stage system elements, performance capabilities, and payload interfaces.
IRIS Toxicological Review of 2,2',4,4'-Tetrabromodiphenyl ...
The U.S. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessments of congeners of polybrominated diphenyl ethers (PDBEs), this review is about 2,2',4,4'-Tetrabromodiphenyl Ether, or commonly referred to as tetraBDE (BDE-47). Following the external peer review this assessment will appear in the Integrated Risk Information System (IRIS) database. Peer review will ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. EPA is updating the Integrated Risk Information System (IRIS) health assessments for the PBDEs.
Jouzdani, Sara; Amini, Rouzbeh; Barocas, Victor H.
2013-01-01
Purpose. To investigate the contribution of three anatomical and physiologic factors (dilator thickness, dynamic pupillary block, and iris compressibility) to changes in iris configuration and anterior chamber angle during pupil dilation. Methods. A mathematical model of the anterior segment based on the average values of ocular dimensions was developed to simulate pupil dilation. To change the pupil diameter from 3.0 to 5.4 mm in 10 seconds, active dilator contraction was applied by imposing stress in the dilator region. Three sets of parameters were varied in the simulations: (1) a thin (4 μm, 1% of full thickness) versus a thick dilator (covering the full thickness iris) to quantify the effects of dilator anatomy, (2) in the presence (+PB) versus absence of pupillary block (−PB) to quantify the effect of dynamic motion of aqueous humor from the posterior to the anterior chamber, and (3) a compressible versus an incompressible iris to quantify the effects of iris volume change. Changes in the apparent iris–lens contact and angle open distance (AOD500) were calculated for each case. Results. The thin case predicted a significant increase (average 700%) in iris curvature compared with the thick case (average 70%), showing that the anatomy of dilator plays an important role in iris deformation during dilation. In the presence of pupillary block (+PB), AOD500 decreased 25% and 36% for the compressible and incompressible iris, respectively. Conclusions. Iris bowing during dilation was driven primarily by posterior location of the dilator muscle and by dynamic pupillary block, but the effect of pupillary block was not as large as that of the dilator anatomy according to the quantified values of AOD500. Incompressibility of the iris, in contrast, had a relatively small effect on iris curvature but a large effect on AOD500; thus, we conclude that all three effects are important. PMID:23482467
IRIS Toxicological Review of 1,4-Dioxane (with Inhalation Update) (Final Report)
The final IRIS Toxicological Review of 1,4-dioxane (with inhalation update) provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to 1,4-dioxane. Human health risk concerns for 1,4-dioxane are primarily relat...
2(2,4,5-Trichlorophenoxy) propionic acid (2,4,5-TP)
Integrated Risk Information System (IRIS)
2 ( 2,4,5 - Trichlorophenoxy ) propionic acid ( 2,4,5 - TP ) ; CASRN 93 - 72 - 1 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Hea
2,2\\',4,4\\',5,5\\'-Hexabromodiphenyl ether (BDE-153)
Integrated Risk Information System (IRIS)
2,2 ' , 4,4 ' , 5,5 ' - Hexabromodiphenyl ether ( BDE - 153 ) ; CASRN 68631 - 49 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I (
2,2\\',4,4\\',5-Pentabromodiphenyl ether (BDE-99)
Integrated Risk Information System (IRIS)
EPA / 635 / R - 07 / 006F www.epa.gov / iris TOXICOLOGICAL REVIEW OF 2,2 ' , 4,4 ' , 5 - PENTABROMODIPHENYL ETHER ( BDE - 99 ) ( CAS No . 60348 - 60 - 9 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) June 2008 U.S . Environmental Protection Agency Washington ,
2,4,5-Trichlorophenoxyacetic acid (2,4,5-T)
Integrated Risk Information System (IRIS)
2,4,5 - Trichlorophenoxyacetic acid ( 2,4,5 - T ) ; CASRN 93 - 76 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard
Retropupillary fixation of iris-claw lens in visual rehabilitation of aphakic eyes.
Jayamadhury, G; Potti, Sudhakar; Kumar, K Vinaya; Kumar, R Madhu; Divyansh Mishra, K C; Nambula, Srinivasa Rao
2016-10-01
Surgical outcome of retropupillary fixation of iris claw lens. To evaluate the various indications, intra and post-operative complications, and visual outcome of retropupillary fixation of iris claw lens in aphakic eyes. The study design is a retrospective study at a tertiary eye care center. Review of medical records of 61 aphakic eyes of 61 patients, who were rehabilitated with retropupillary fixation of an iris claw lens, with a follow-up duration of at least 1 year. Data analysis was performed using paired t-test and Chi-square test. Mean preoperative uncorrected visual acuity was 1.66 ± 0.3 LogMAR and postoperative acuity at 1 year was 0.53 ± 0.5 LogMAR (P = 0.00001). Preoperative distant best-corrected visual acuity was 0.30 ± 0.48 LogMAR and postoperative acuity at 1 year was 0.27 ± 0.46 LogMAR (P = 0.07). Mean preoperative astigmatism was 1.43 ± 1.94 D and postoperatively was 1.85 ± 2.16 D (P = 0.0127). Mean endothelial cell count was 2353.52 ± 614 cells/mm2 preoperatively which decreased to 2200 ± 728 cells/mm2 at 1 year follow-up (P = 0.006). There was no significant difference in central macular thickness and intraocular pressure pre and post-surgery. Complications included ovalization of pupil in 9.83%, hypotony in 1.63%, toxic anterior segment syndrome in 1.63%, cystoid macular edema in 11.47%, epiretinal membrane in 3.27%, and iris atrophy in 6.55%. Iris claw is a safe and an effective method of rehabilitating aphakic eyes.
Qing, Guoping; Zhang, Shaodan; Wang, Huaizhou; Wang, Tao; Wang, Shuhua; Chen, Hong; Wang, Hua; Wang, Ningli
2014-07-01
To evaluate the long-term efficacy of laser peripheral iridotomy (LPI) in preventing deterioration in eyes with pigment dispersion syndrome (PDS). A cohort study. Nineteen patients with PDS were treated with LPI and followed up periodically in Beijing Tongren Eye Center from May 2006 to April 2007. One eye of each patient was chosen randomly for the study. Main investigating items included iris configuration, intraocular pressure (IOP), anterior chamber pigmentation, and visual field analysis. The average follow-up period was (6.5 ± 0.3) years. A paired sample t test was used to determine whether there is a significant difference between average values of pre- and post-LPI IOP and mean deviation of Humphrey visual field analysis in these PDS eyes. The average age of the 19 patients were (35.8 ± 7.1) years on admission. The initial IOP of the 19 eyes was (24.7 ± 2.2) mmHg (1 mmHg = 0.133 kPa) before LPI. The mean deviation (MD) of Humphrey visual field analysis (VFA) were (-1.82 ± 1.26) dB (-4.34--0.28 dB) . All 19 eyes had concave iris and heavy trabecular pigmentation. The iris became flat in all PDS eyes after the laser treatment. At the last follow-up visit, the average IOP was 14.8 ± 2.0 (12-20) mmHg, which was statistically lower than that of baseline (t = 11.49, P < 0.01) . Extent of trabecular pigmentation reduced obviously in 16 eyes. No deterioration or new visual field defect was detected in any of the PDS eyes. MD of the last VFA was -1.79 ± 1.21 (-4.39--0.21 dB) . There was no statistical difference between MD of the last VFA and baseline (t = -0.26, P = 0.798). The long-term follow-up results showed that LPI prevents progression effectively in eyes with PDS.
Integrated Risk Information System (IRIS)
4 - Aminopyridine ; CASRN 504 - 24 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic
Integrated Risk Information System (IRIS)
4 - Methylphenol ; CASRN 106 - 44 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic
The Interface Region Imaging Spectrograph (IRIS) Small Explorer
NASA Astrophysics Data System (ADS)
de Pontieu, B.; Title, A. M.; Schryver, C. J.; Lemen, J. R.; Golub, L.; Kankelborg, C. C.; Carlsson, M.
2009-12-01
The Interface Region Imaging Spectrograph (IRIS) was recently selected as a small explorer mission by NASA. The primary goal of IRIS is to understand how the solar atmosphere is energized. The IRIS investigation combines advanced numerical modeling with a high resolution 20 cm UV imaging spectrograph that will obtain spectra covering temperatures from 4,500 to 10 MK in three wavelength ranges (1332-1358 Angstrom, 1390-1406 Angstrom and 2785-2835 Angstrom) and simultaneous images covering temperatures from 4,500 K to 65,000 K. IRIS will obtain UV spectra and images with high resolution in space (1/3 arcsec) and time (1s) focused on the chromosphere and transition region of the Sun, a complex dynamic interface region between the photosphere and corona. In this region, all but a few percent of the non-radiative energy leaving the Sun is converted into heat and radiation. IRIS fills a crucial gap in our ability to advance Sun-Earth connection studies by tracing the flow of energy and plasma through this foundation of the corona and heliosphere. The IRIS investigation is led by PI Alan Title (LMSAL) with major participation by the Harvard Smithsonian Astrophysical Observatory, Montana State University, NASA Ames Research Center, Stanford University and the University of Oslo (Norway). IRIS is scheduled for launch in late 2012, and will have a nominal two year mission lifetime.
Iris Recognition: The Consequences of Image Compression
NASA Astrophysics Data System (ADS)
Ives, Robert W.; Bishop, Daniel A.; Du, Yingzi; Belcher, Craig
2010-12-01
Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA) is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.
2003-09-01
type as staged at sites one and two. -T.N Jt- ’I,-’ 7 "A` fl-b - "’, j’¾ liti -- S Z ANZIC D -j Z" itN L/ ’ Hrt Irk ~ SG~i’ 18 DRDC Otaw TM 2003142...initialisms .............................................................. 129 Vi DRDC Ottawa TM 2003-142 List of figures... - s - f ur e...be found in [6, 7, 8, 9]. PolSAR utilizes the information available from the polarimetric ellipse to determine the physical structure( s ) that the
Technical issues for the eye image database creation at distance
NASA Astrophysics Data System (ADS)
Oropesa Morales, Lester Arturo; Maldonado Cano, Luis Alejandro; Soto Aldaco, Andrea; García Vázquez, Mireya Saraí; Zamudio Fuentes, Luis Miguel; Rodríguez Vázquez, Manuel Antonio; Pérez Rosas, Osvaldo Gerardo; Rodríguez Espejo, Luis; Montoya Obeso, Abraham; Ramírez Acosta, Alejandro Álvaro
2016-09-01
Biometrics refers to identify people through their physical characteristics or behavior such as fingerprints, face, DNA, hand geometries, retina and iris patterns. Typically, the iris pattern is to acquire in short distance to recognize a person, however, in the past few years is a challenge identify a person by its iris pattern at certain distance in non-cooperative environments. This challenge comprises: 1) high quality iris image, 2) light variation, 3) blur reduction, 4) specular reflections reduction, 5) the distance from the acquisition system to the user, and 6) standardize the iris size and the density pixel of iris texture. The solution of the challenge will add robustness and enhance the iris recognition rates. For this reason, we describe the technical issues that must be considered during iris acquisition. Some of these considerations are the camera sensor, lens, the math analysis of depth of field (DOF) and field of view (FOV) for iris recognition. Finally, based on this issues we present experiment that show the result of captures obtained with our camera at distance and captures obtained with cameras in very short distance.
NASA Astrophysics Data System (ADS)
Shekar, B. H.; Bhat, S. S.
2017-05-01
Locating the boundary parameters of pupil and iris and segmenting the noise free iris portion are the most challenging phases of an automated iris recognition system. In this paper, we have presented person authentication frame work which uses particle swarm optimization (PSO) to locate iris region and circular hough transform (CHT) to device the boundary parameters. To undermine the effect of the noise presented in the segmented iris region we have divided the candidate region into N patches and used Fuzzy c-means clustering (FCM) to classify the patches into best iris region and not so best iris region (noisy region) based on the probability density function of each patch. Weighted mean Hammimng distance is adopted to find the dissimilarity score between the two candidate irises. We have used Log-Gabor, Riesz and Taylor's series expansion (TSE) filters and combinations of these three for iris feature extraction. To justify the feasibility of the proposed method, we experimented on the three publicly available data sets IITD, MMU v-2 and CASIA v-4 distance.
2011-03-30
or remediation Used with regulatory values to determine cleanup levels Risk-based screening levels (aka PRGs, RBCs, RSLs) ►Screen sites early in...Final IRIS Values for Hydrogen Cyanide and Cyanide Salts (September 2010) New Oral noncancer RfD = 0.0006 mg/kg- day; male reproduction effects
Enhanced iris recognition method based on multi-unit iris images
NASA Astrophysics Data System (ADS)
Shin, Kwang Yong; Kim, Yeong Gon; Park, Kang Ryoung
2013-04-01
For the purpose of biometric person identification, iris recognition uses the unique characteristics of the patterns of the iris; that is, the eye region between the pupil and the sclera. When obtaining an iris image, the iris's image is frequently rotated because of the user's head roll toward the left or right shoulder. As the rotation of the iris image leads to circular shifting of the iris features, the accuracy of iris recognition is degraded. To solve this problem, conventional iris recognition methods use shifting of the iris feature codes to perform the matching. However, this increases the computational complexity and level of false acceptance error. To solve these problems, we propose a novel iris recognition method based on multi-unit iris images. Our method is novel in the following five ways compared with previous methods. First, to detect both eyes, we use Adaboost and a rapid eye detector (RED) based on the iris shape feature and integral imaging. Both eyes are detected using RED in the approximate candidate region that consists of the binocular region, which is determined by the Adaboost detector. Second, we classify the detected eyes into the left and right eyes, because the iris patterns in the left and right eyes in the same person are different, and they are therefore considered as different classes. We can improve the accuracy of iris recognition using this pre-classification of the left and right eyes. Third, by measuring the angle of head roll using the two center positions of the left and right pupils, detected by two circular edge detectors, we obtain the information of the iris rotation angle. Fourth, in order to reduce the error and processing time of iris recognition, adaptive bit-shifting based on the measured iris rotation angle is used in feature matching. Fifth, the recognition accuracy is enhanced by the score fusion of the left and right irises. Experimental results on the iris open database of low-resolution images showed that the averaged equal error rate of iris recognition using the proposed method was 4.3006%, which is lower than that of other methods.
Texture Feature Extraction and Classification for Iris Diagnosis
NASA Astrophysics Data System (ADS)
Ma, Lin; Li, Naimin
Appling computer aided techniques in iris image processing, and combining occidental iridology with the traditional Chinese medicine is a challenging research area in digital image processing and artificial intelligence. This paper proposes an iridology model that consists the iris image pre-processing, texture feature analysis and disease classification. To the pre-processing, a 2-step iris localization approach is proposed; a 2-D Gabor filter based texture analysis and a texture fractal dimension estimation method are proposed for pathological feature extraction; and at last support vector machines are constructed to recognize 2 typical diseases such as the alimentary canal disease and the nerve system disease. Experimental results show that the proposed iridology diagnosis model is quite effective and promising for medical diagnosis and health surveillance for both hospital and public use.
IRIS Toxicological Review of 1,4-Dioxane (Final Report)
EPA announced the release of the final report, Toxicological Review of 1,4-Dioxane (CAS No. 123-91-1): In Support of Summary Information on the Integrated Risk Information System (IRIS). The final Toxicological Review of 1,4-dioxane provides scientific support and rationa...
Serine/threonine kinase, Cot/Tpl2, regulates renal cell apoptosis in ischaemia/reperfusion injury.
Yaomura, Takaaki; Tsuboi, Naotake; Urahama, Yoshinori; Hobo, Akinori; Sugimoto, Kenji; Miyoshi, Jun; Matsuguchi, Tetsuya; Reiji, Kannagi; Matsuo, Seiichi; Yuzawa, Yukio
2008-10-01
Cot/Tpl2, a serine/threonine (Ser/Thr) protein kinase, has been classified as a member of the mitogen-activated protein kinase (MAPK) family, and is known to have a pleiotropic role. Many studies have reported the involvement of Cot/Tpl2, mainly as a member of the Toll-like receptor (TLR) 4 signalling pathway in lipopolysaccharide (LPS)-induced tumor necrosis factor-alpha (TNF-alpha) production. At the same time, it is also related to the caspase-dependent apoptotic pathway. Thus, the role of Cot/Tpl2 in ischaemia/reperfusion injury (IRI) in which TNF-alpha and apoptosis are the major pathogenetic factors was studied. IRI was induced in wild type (Cot/Tpl2(+/+)) mice and in Cot/Tpl2-deficient (Cot/Tpl2(-/-)) mice. The extent of tubular injury and renal function were studied. TNF-alpha production, neutrophil infiltration and apoptosis were also compared between the two groups. Cot/Tpl2(-/-) mice had preserved renal function compared with wild type mice in IRI. Although Cot/Tpl2 was phosphorylated in IRI and in the cultured tubular epithelial cells (TEC) after stimulation with LPS and hydrogen peroxide, there were no significant differences in terms of TNF-alpha production, neutrophil infiltration or MAPK activation between Cot/Tpl2(+/+) and Cot/Tpl2(-/-) mice. In contrast, Cot/Tpl2(-/-) mice showed obviously reduced terminal deoxynucleotidyl transferase-mediated dUTP nick end labelling positive cells and cleaved caspase-3 positive cells. Furthermore, Cot/Tpl2-deficient TECs demonstrated significantly less caspase-3 activation after hydrogen peroxide stimulation with comparable caspase-9 activation to wild type TEC. Cot/Tpl2 did not function as a member of MAPK family, but as a promoter of apoptosis in IRI. These results suggest that Cot/Tpl2 could be a possible therapeutic target in IRI.
Parallel 3D Mortar Element Method for Adaptive Nonconforming Meshes
NASA Technical Reports Server (NTRS)
Feng, Huiyu; Mavriplis, Catherine; VanderWijngaart, Rob; Biswas, Rupak
2004-01-01
High order methods are frequently used in computational simulation for their high accuracy. An efficient way to avoid unnecessary computation in smooth regions of the solution is to use adaptive meshes which employ fine grids only in areas where they are needed. Nonconforming spectral elements allow the grid to be flexibly adjusted to satisfy the computational accuracy requirements. The method is suitable for computational simulations of unsteady problems with very disparate length scales or unsteady moving features, such as heat transfer, fluid dynamics or flame combustion. In this work, we select the Mark Element Method (MEM) to handle the non-conforming interfaces between elements. A new technique is introduced to efficiently implement MEM in 3-D nonconforming meshes. By introducing an "intermediate mortar", the proposed method decomposes the projection between 3-D elements and mortars into two steps. In each step, projection matrices derived in 2-D are used. The two-step method avoids explicitly forming/deriving large projection matrices for 3-D meshes, and also helps to simplify the implementation. This new technique can be used for both h- and p-type adaptation. This method is applied to an unsteady 3-D moving heat source problem. With our new MEM implementation, mesh adaptation is able to efficiently refine the grid near the heat source and coarsen the grid once the heat source passes. The savings in computational work resulting from the dynamic mesh adaptation is demonstrated by the reduction of the the number of elements used and CPU time spent. MEM and mesh adaptation, respectively, bring irregularity and dynamics to the computer memory access pattern. Hence, they provide a good way to gauge the performance of computer systems when running scientific applications whose memory access patterns are irregular and unpredictable. We select a 3-D moving heat source problem as the Unstructured Adaptive (UA) grid benchmark, a new component of the NAS Parallel Benchmarks (NPB). In this paper, we present some interesting performance results of ow OpenMP parallel implementation on different architectures such as the SGI Origin2000, SGI Altix, and Cray MTA-2.
Building an Integrated Environment for Multimedia
NASA Technical Reports Server (NTRS)
1997-01-01
Multimedia courseware on the solar system and earth science suitable for use in elementary, middle, and high schools was developed under this grant. The courseware runs on Silicon Graphics, Incorporated (SGI) workstations and personal computers (PCs). There is also a version of the courseware accessible via the World Wide Web. Accompanying multimedia database systems were also developed to enhance the multimedia courseware. The database systems accompanying the PC software are based on the relational model, while the database systems accompanying the SGI software are based on the object-oriented model.
Trace-Driven Debugging of Message Passing Programs
NASA Technical Reports Server (NTRS)
Frumkin, Michael; Hood, Robert; Lopez, Louis; Bailey, David (Technical Monitor)
1998-01-01
In this paper we report on features added to a parallel debugger to simplify the debugging of parallel message passing programs. These features include replay, setting consistent breakpoints based on interprocess event causality, a parallel undo operation, and communication supervision. These features all use trace information collected during the execution of the program being debugged. We used a number of different instrumentation techniques to collect traces. We also implemented trace displays using two different trace visualization systems. The implementation was tested on an SGI Power Challenge cluster and a network of SGI workstations.
Integrated Risk Information System (IRIS)
3,4 - Dimethylphenol ; CASRN 95 - 65 - 8 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogen
Integrated Risk Information System (IRIS)
2,4 - Dinitrotoluene ; CASRN 121 - 14 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinoge
Integrated Risk Information System (IRIS)
2,4 - Dichlorophenol ; CASRN 120 - 83 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinoge
Integrated Risk Information System (IRIS)
2,4 - Dinitrophenol ; CASRN 51 - 28 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogeni
Integrated Risk Information System (IRIS)
2,4 - Dimethylphenol ; CASRN 105 - 67 - 9 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinoge
Integrated Risk Information System (IRIS)
2,4 - Diaminotoluene ; CASRN 95 - 80 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogen
Integrated Risk Information System (IRIS)
1,4 - Dibromobenzene ; CASRN 106 - 37 - 6 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinoge
Integrated Risk Information System (IRIS)
1,4 - Dichlorobenzene ; CASRN 106 - 46 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinog
The influence of iris color on the pupillary light reflex.
Bergamin, O; Schoetzau, A; Sugimoto, K; Zulauf, M
1998-08-01
This study was carried out to investigate the effect of iris color on the pupillary light reflex (PLR) in normal healthy volunteers. Pupil perimetry was performed on 50 healthy volunteers with the Octopus 1-2-3 automated perimeter. Within the 30-deg visual field, 33 test locations were investigated four times. Stimulus parameters were Goldmann size V (1.72 degrees), intensity 1632 cd/m2, stimulus time 200 ms, background illumination 0 cd/m2, and interstimulus interval 3 s. Pupillometric parameters studied were initial pupil size, amplitude (magnitude of pupillary contraction), latency time, contraction time, pre-PLR movement, contraction velocity, and redilation velocity. Pupillometric parameters were investigated by analysis of variance by the independent variables blue and brown irides. Iris color (blue vs brown) influenced statistically significantly (P < 0.05) amplitude (0.504 mm vs 0.594 mm), contraction time (401 ms vs 407 ms), contraction velocity (13.75 mm2/s vs 16.01 mm2/s), and redilation velocity (4.80 mm2/s vs 5.66 mm2/s). Iris color did not influence initial pupil size (4.78 mm vs 4.83 mm), latency time (520 mm vs 521 ms), and pre-PLR movement (0.328 mm2/s vs 0.325 mm2/s). Pupillary contraction amplitude and velocity depended on iris color, whereas pupil size and latency time were independent of iris color. Therefore, iris color might be considered when, evaluating pupillary movements in pupil perimetry.
Lyra, Marcelo Rosandiski; Nascimento, Maria Letícia Fernandes Oliveira; Varon, Andréa Gina; Pimentel, Maria Inês Fernandes; Antonio, Liliane de Fátima; Saheki, Maurício Naoto; Bedoya-Pacheco, Sandro Javier; Valle, Antonio Carlos Francesconi do
2014-01-01
We report 2 cases of patients with immune reconstitution inflammatory syndrome (IRIS) associated with cutaneous disseminated sporotrichosis and human immunodeficiency virus (HIV) coinfection. The patients received specific treatment for sporotrichosis. However, after 4 and 5 weeks from the beginning of antiretroviral therapy, both patients experienced clinical exacerbation of skin lesions despite increased T CD4+ cells (T cells cluster of differentiation 4 positive) count and decreased viral load. Despite this exacerbation, subsequent mycological examination after systemic corticosteroid administration did not reveal fungal growth. Accordingly, they were diagnosed with IRIS. However, the sudden withdrawal of the corticosteroids resulted in the recurrence of IRIS symptoms. No serious adverse effects could be attributed to prednisone. We recommend corticosteroid treatment for mild-to-moderate cases of IRIS in sporotrichosis and HIV coinfection with close follow-up.
Reconstruction of a helical prominence in 3D from IRIS spectra and images
NASA Astrophysics Data System (ADS)
Schmieder, B.; Zapiór, M.; López Ariste, A.; Levens, P.; Labrosse, N.; Gravet, R.
2017-10-01
Context. Movies of prominences obtained by space instruments e.g. the Solar Optical Telescope (SOT) aboard the Hinode satellite and the Interface Region Imaging Spectrograph (IRIS) with high temporal and spatial resolution revealed the tremendous dynamical nature of prominences. Knots of plasma belonging to prominences appear to travel along both vertical and horizontal thread-like loops, with highly dynamical nature. Aims: The aim of the paper is to reconstruct the 3D shape of a helical prominence observed over two and a half hours by IRIS. Methods: From the IRIS Mg II k spectra we compute Doppler shifts of the plasma inside the prominence and from the slit-jaw images (SJI) we derive the transverse field in the plane of the sky. Finally we obtain the velocity vector field of the knots in 3D. Results.We reconstruct the real trajectories of nine knots travelling along ellipses. Conclusions: The spiral-like structure of the prominence observed in the plane of the sky is mainly due to the projection effect of long arches of threads (up to 8 × 104 km). Knots run along more or less horizontal threads with velocities reaching 65 km s-1. The dominant driving force is the gas pressure. Movies associated to Figs. 1, 9, 10, and 13 are available at http://www.aanda.org
NASA Technical Reports Server (NTRS)
Bidwell, Colin S.; Papadakis, Michael
2005-01-01
Collection efficiency and ice accretion calculations have been made for a series of business jet horizontal tail configurations using a three-dimensional panel code, an adaptive grid code, and the NASA Glenn LEWICE3D grid based ice accretion code. The horizontal tail models included two full scale wing tips and a 25 percent scale model. Flow solutions for the horizontal tails were generated using the PMARC panel code. Grids used in the ice accretion calculations were generated using the adaptive grid code ICEGRID. The LEWICE3D grid based ice accretion program was used to calculate impingement efficiency and ice shapes. Ice shapes typifying rime and mixed icing conditions were generated for a 30 minute hold condition. All calculations were performed on an SGI Octane computer. The results have been compared to experimental flow and impingement data. In general, the calculated flow and collection efficiencies compared well with experiment, and the ice shapes appeared representative of the rime and mixed icing conditions for which they were calculated.
COSAGE (Concepts Analysis Agency’s Combat Sample Generator) Analysis and Design Report. Volume 2
1984-04-29
Law 1-0 L L- o : Ir-I- lz 9 LL 4 i-w z o Li W w-- n 17 a. I.-- I.-.- 41- In I in 4 - I.- w w 0. ---- - - - -Inn w WWw IWWL U "-J I.-n I.:-0 I.:V W...S> U) M. V) U)( -j 1-. U)CflU)iW AJLL - CA~ 0(9 9( Iij _j 4c.-...- - . . . V )V )UU0 _j .- F_ .-I -W LL WL -) 1- - .. J.J.J U U)A WO LL P.- 1.- * WWW ...I’ 4< 4 o w Q e~~ glrS . ftc- www ~w~uw ~ NW)* WNPOQO -qp t It V -I- P P.P. Dr. OD O ODif)OD 1) f) i inIS D O 40IS t ( D COD 0 O to D O Z OD GD LAI
Integrated Risk Information System (IRIS)
2,2,4 - Trimethylpentane ; CASRN 540 - 84 - 1 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarci
Integrated Risk Information System (IRIS)
1,2,4 - Tribromobenzene ; CASRN 615 - 54 - 3 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcin
Integrated Risk Information System (IRIS)
2,4,6 - Trichlorophenol ; CASRN 88 - 06 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcino
Integrated Risk Information System (IRIS)
1,4 - Dithiane ; CASRN 505 - 29 - 3 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Ef
Integrated Risk Information System (IRIS)
EPA / 635 / R - 11 / 003F www.epa.gov / iris TOXICOLOGICAL REVIEW OF 1,4 - DIOXANE ( WITH INHALATION UPDATE ) ( CAS No . 123 - 91 - 1 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) September 2013 U.S . Environmental Protection Agency Washington , DC DISCLAIMER
Integrated Risk Information System (IRIS)
1,2,4 - Trichlorobenzene ; CASRN 120 - 82 - 1 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarci
New methods in iris recognition.
Daugman, John
2007-10-01
This paper presents the following four advances in iris recognition: 1) more disciplined methods for detecting and faithfully modeling the iris inner and outer boundaries with active contours, leading to more flexible embedded coordinate systems; 2) Fourier-based methods for solving problems in iris trigonometry and projective geometry, allowing off-axis gaze to be handled by detecting it and "rotating" the eye into orthographic perspective; 3) statistical inference methods for detecting and excluding eyelashes; and 4) exploration of score normalizations, depending on the amount of iris data that is available in images and the required scale of database search. Statistical results are presented based on 200 billion iris cross-comparisons that were generated from 632500 irises in the United Arab Emirates database to analyze the normalization issues raised in different regions of receiver operating characteristic curves.
NASA Astrophysics Data System (ADS)
Ameen, Muhammad Ayyaz; Khursheed, Haqqa; Jabbar, Mehak Abdul; Ali, Muneeza Salman; Chishtie, Farrukh
2018-04-01
We report the results of ionospheric measurements from DPS-4 installed at Multan (Geog coord. 30.18°N, 71.48°E, dip 47.4°). The variations in F2-layer maximum electron density NmF2 and its peak height hmF2 are studied during the deep solar minimum between cycles 23 & 24 i.e 2008-2009 with comparisons conducted with the International Reference Ionosphere (IRI) versions 2012 & 2016. We find that the hmF2 observations peak around the pre-sunrise and sunrise hours depending on the month. Seasonally, the daytime variation of NmF2 is higher in the Equinox and Summer, while daytime hmF2 are slightly higher in the Equinox and Winter. High values of hmF2 around midnight are caused by an increase of upward drifts produced by meridional winds. The ionosphere over Multan, which lies at the verge of low and mid latitude, is affected by both E × B drifts and thermospheric winds as evident from mid-night peaks and near-sunrise dips in hmF2. The results of the comparison of the observed NmF2 and hmF2 for the year 2008-2009 with the IRI-2012 (both NmF2 and hmF2) and IRI-2016 (only hmF2) estimates indicate that for NmF2, IRI-2012 with Consultative Committee International Radio (CCIR) option produces values in better agreement with observed data. Whereas, for hmF2, IRI-2016 with both International Union of Radio Science (URSI) and CCIR SHU-2015 options, predicts well for nighttime hours throughout the year. However, the IRI-2012 with CCIR option produces better agreement with data during daytime hours. Furthermore, IRI-2012 with CCIR option gives better results during Equinox months, whereas, IRI-2016 with both URSI and CCIR SHU-2015 options predict well for Winter and Summer.
Rb-Silva, Rita; Nobrega, Claudia; Reiriz, Eugénia; Almeida, Soraia; Sarmento-Castro, Rui; Correia-Neves, Margarida; Horta, Ana
2017-01-13
HIV-infected patients may present an unforeseen clinical worsening after initiating antiretroviral therapy known as immune reconstitution inflammatory syndrome (IRIS). This syndrome is characterized by a heightened inflammatory response toward infectious or non-infectious triggers, and it may affect different organs. Diagnosis of IRIS involving the central nervous system (CNS-IRIS) is challenging due to heterogeneous manifestations, absence of biomarkers to identify this condition, risk of long-term sequelae and high mortality. Hence, a deeper knowledge of CNS-IRIS pathogenesis is needed. A 37-year-old man was diagnosed with AIDS and cerebral toxoplasmosis. Anti-toxoplasma treatment was initiated immediately, followed by active antiretroviral therapy (HAART) 1 month later. At 2 months of HAART, he presented with progressive hyposensitivity of the right lower limb associated with brain and dorsal spinal cord lesions, compatible with paradoxical toxoplasmosis-associated CNS-IRIS, a condition with very few reported cases. A stereotactic biopsy was planned but was postponed based on its inherent risks. Patient showed clinical improvement with no requirement of corticosteroid therapy. Routine laboratorial analysis was complemented with longitudinal evaluation of blood T cell subsets at 0, 1, 2, 3 and 6 months upon HAART initiation. A control group composed by 9 HIV-infected patients from the same hospital but with no IRIS was analysed for comparison. The CNS-IRIS patient showed lower percentage of memory CD4 + T cells and higher percentage of activated CD4 + T cells at HAART initiation. The percentage of memory CD4 + T cells drastically increased at 1 month after HAART initiation and became higher in comparison to the control group until clinical recovery onset; the percentage of memory CD8 + T cells was consistently lower throughout follow-up. Interestingly, the percentage of regulatory T cells (Treg) on the CNS-IRIS patient reached a minimum around 1 month before symptoms onset. Although both stereotactic biopsies and steroid therapy might be of use in CNS-IRIS cases and should be considered for these patients, they might be unnecessary to achieve clinical improvement as shown in this case. Immunological characterization of more CNS-IRIS cases is essential to shed some light on the pathogenesis of this condition.
Letang, Emilio; Lewis, James J; Bower, Mark; Mosam, Anisa; Borok, Margareth; Campbell, Thomas B; Naniche, Denise; Newsom-Davis, Tom; Shaik, Fahmida; Fiorillo, Suzanne; Miro, Jose M; Schellenberg, David; Easterbrook, Philippa J
2013-06-19
To assess the incidence, predictors, and outcomes of Kaposi sarcoma-associated paradoxical immune reconstitution inflammatory syndrome (KS-IRIS) in antiretroviral therapy (ART)-naive HIV-infected patients with Kaposi sarcoma initiating ART in both well resourced and limited-resourced settings. Pooled analysis of three prospective cohorts of ART-naive HIV-infected patients with Kaposi sarcoma from sub-Saharan Africa (SSA) and one from the UK. KS-IRIS case definition was standardized across sites. Cox regression and Kaplan-Meier survival analysis were used to identify the incidence and predictors of KS-IRIS and Kaposi sarcoma-associated mortality. Fifty-eight of 417 (13.9%) eligible individuals experienced KS-IRIS with an incidence 2.5 times higher in the African vs. European cohorts (P=0.001). ART alone as initial Kaposi sarcoma treatment (hazard ratio 2.97, 95% confidence interval (CI) 1.02-8.69); T1 Kaposi sarcoma stage (hazard ratio 2.96, 95% CI 1.26-6.94); and plasma HIV-1 RNA more than 5 log₁₀ copies/ml (hazard ratio 2.14, 95% CI 1.25-3.67) independently predicted KS-IRIS at baseline. Detectable plasma Kaposi sarcoma-associated herpes virus (KSHV) DNA additionally predicted KS-IRIS among the 259 patients with KSHV DNA assessed (hazard ratio 2.98, 95% CI 1.23-7.19). Nineteen KS-IRIS patients died, all in SSA. Kaposi sarcoma mortality was 3.3-fold higher in Africa, and was predicted by KS-IRIS (hazard ratio 19.24, CI 7.62-48.58), lack of chemotherapy (hazard ratio 2.35, 95% CI 1.09-5.05), pre-ART CD4 cell count less than 200 cells/μl (hazard ratio 2.04, 95% CI 0.99-4.2), and detectable baseline KSHV DNA (hazard ratio 2.12, 95% CI 0.94-4.77). KS-IRIS incidence and mortality are higher in SSA than in the UK. This is largely explained by the more advanced Kaposi sarcoma disease and lower chemotherapy availability. KS-IRIS is a major contributor to Kaposi sarcoma-associated mortality in Africa. Our results support the need to increase awareness on KS-IRIS, encourage earlier presentation, referral and diagnosis of Kaposi sarcoma, and advocate on access to systemic chemotherapy in Africa. © 2013 Wolters Kluwer Health | Lippincott Williams & Wilkins
Li, Ming; Cheng, Hongbo; Guo, Ping; Zhang, Chun; Tang, Song; Wang, Shusheng
2016-04-26
Iris plays important roles in ocular physiology and disease pathogenesis. Currently it is technically challenging to noninvasively examine the human iris ultrastructure in vivo. The purpose of the current study is to reveal human iris ultrastructure in patients with synechiae by using noninvasive in vivo laser scanning confocal microscopy (LSCM). The ultrastructure of iris in thirty one patients, each with synechiae but transparent cornea, was examined by in vivo LSCM. Five characteristic iris ultrastructures was revealed in patients with synechiae by in vivo LSCM, which include: 1. tree trunk-like structure; 2. tree branch/bush-like structure; 3. Fruit-like structure; 4. Epithelioid-like structure; 5. deep structure. Pigment granules can be observed as a loose structure on the top of the arborization structure. In iris-associated diseases with Tyndall's Phenomenon and keratic precipitates, the pigment particles are more likely to fall off from the arborization structure. The ultrastructure of iris in patients with synechiae has been visualized using in vivo LSCM. Five iris ultrastructures can be clearly observed, with some of the structures maybe disease-associated. The fall-off of the pigment particles may cause the Tyndall's Phenomenon positive. In vivo LSCM provides a non-invasive approach to observe the human iris ultrastructure under certain eye disease conditions, which sets up a foundation to visualize certain iris-associated diseases in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parsons, David, E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca; Robar, James L., E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca
2015-09-15
Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kilovoltage-cone beam CT (CBCT) using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of 1D translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian On-Board Imager system. CBCT and planar image quality were investigated as a function of aperture radius, while maintaining the same dose to the VOI,more » for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various sizes VOI were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 to 2.4 cm (at isocenter). Depending upon VOI location and size, dose was reduced to 16%–90% of the full-field value along the central axis plane and down to 4% along the axis of rotation, while maintaining the same dose to the VOI compared to full-field techniques. When maintaining constant dose to the VOI, this change in iris diameter corresponds to a factor increase of approximately 1.6 in image contrast and a factor decrease in image noise of approximately 1.2. This results in a measured gain in contrast-to-noise ratio by a factor of approximately 2.0. Conclusions: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.« less
NASA Astrophysics Data System (ADS)
Walter, R. J.; Protack, S. P.; Harris, C. J.; Caruthers, C.; Kusterer, J. M.
2008-12-01
NASA's Atmospheric Science Data Center at the NASA Langley Research Center performs all of the science data processing for the Multi-angle Imaging SpectroRadiometer (MISR) instrument. MISR is one of the five remote sensing instruments flying aboard NASA's Terra spacecraft. From the time of Terra launch in December 1999 until February 2008, all MISR science data processing was performed on a Silicon Graphics, Inc. (SGI) platform. However, dramatic improvements in commodity computing technology coupled with steadily declining project budgets during that period eventually made transitioning MISR processing to a commodity computing environment both feasible and necessary. The Atmospheric Science Data Center has successfully ported the MISR science data processing environment from the SGI platform to a Linux cluster environment. There were a multitude of technical challenges associated with this transition. Even though the core architecture of the production system did not change, the manner in which it interacted with underlying hardware was fundamentally different. In addition, there are more potential throughput bottlenecks in a cluster environment than there are in a symmetric multiprocessor environment like the SGI platform and each of these had to be addressed. Once all the technical issues associated with the transition were resolved, the Atmospheric Science Data Center had a MISR science data processing system with significantly higher throughput than the SGI platform at a fraction of the cost. In addition to the commodity hardware, free and open source software such as S4PM, Sun Grid Engine, PostgreSQL and Ganglia play a significant role in the new system. Details of the technical challenges and resolutions, software systems, performance improvements, and cost savings associated with the transition will be discussed. The Atmospheric Science Data Center in Langley's Science Directorate leads NASA's program for the processing, archival and distribution of Earth science data in the areas of radiation budget, clouds, aerosols, and tropospheric chemistry. The Data Center was established in 1991 to support NASA's Earth Observing System and the U.S. Global Change Research Program. It is unique among NASA data centers in the size of its archive, cutting edge computing technology, and full range of data services. For more information regarding ASDC data holdings, documentation, tools and services, visit http://eosweb.larc.nasa.gov
Design and performance of a cryogenic iris aperture mechanism
NASA Astrophysics Data System (ADS)
de Jonge, C.; Laauwen, W. M.; de Vries, E. A.; Smit, H. P.; Detrain, A.; Eggens, M. J.; Ferrari, L.; Dieleman, P.
2014-07-01
A cryogenic iris mechanism is under development as part of the ground calibration source for the SAFARI instrument. The iris mechanism is a variable aperture used as an optical shutter to fine-tune and modulate the absolute power output of the calibration source. It has 4 stainless steel blades that create a near-circular aperture in every position. The operating temperature is 4.5 Kelvin to provide a negligible background to the SAFARI detectors, and `hot spots' above 9K should be prevented. Cryogenic testing proved that the iris works at 4K. It can be used in a broad range of cryogenic optical instruments where optical throughput needs to be controlled. Challenges in the design include the low cooling power available (5mW) and low friction at cryogenic temperatures. The actuator is an `arc-type' rotary voice-coil motor. The use of flexural pivots creates a mono-stable mechanism with a resonance frequency at 26Hz. Accurate and fast position control with disturbance rejection is managed by a PID servo loop using a hall-sensor as input. At 4 Kelvin, the frequency is limited to 4Hz to avoid excess dissipation and heating. In this paper, the design and performance of the iris are discussed. The design was optimized using a thermal, magnetic and mechanical model made with COMSOL Finite Element Analysis software. The dynamical and state-space modeling of the mechanism and the concept of the electrical control are presented. The performance of the iris show good agreement to the analytical and COMSOL modeling.
IRIS Toxicological Review of 1,4-Dioxane (External Review Draft, 2009)
EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-dioxane that when finalized will appear on the Integrated Risk Information System (IRIS) database.
2,4-/2,6-Dinitrotoluene mixture
Integrated Risk Information System (IRIS)
2,4 - / 2,6 - Dinitrotoluene mixture ; no CASRN Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncar
Integrated Risk Information System (IRIS)
2,3,4,6 - Tetrachlorophenol ; CASRN 58 - 90 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncar
Integrated Risk Information System (IRIS)
1,2,4,5 - Tetrachlorobenzene ; CASRN 95 - 94 - 3 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Nonca
4,6-Dinitro-o-cyclohexyl phenol
Integrated Risk Information System (IRIS)
4,6 - Dinitro - o - cyclohexyl phenol ; CASRN 131 - 89 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments
Integrated Risk Information System (IRIS)
2,4,6 - Trinitrotoluene ( TNT ) ; CASRN 118 - 96 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for N
2-Methyl-4-chlorophenoxyacetic acid (MCPA)
Integrated Risk Information System (IRIS)
2 - Methyl - 4 - chlorophenoxyacetic acid ( MCPA ) ; CASRN 94 - 74 - 6 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard
Eclipse-Free-Time Assessment Tool for IRIS
NASA Technical Reports Server (NTRS)
Eagle, David
2012-01-01
IRIS_EFT is a scientific simulation that can be used to perform an Eclipse-Free- Time (EFT) assessment of IRIS (Infrared Imaging Surveyor) mission orbits. EFT is defined to be those time intervals longer than one day during which the IRIS spacecraft is not in the Earth s shadow. Program IRIS_EFT implements a special perturbation of orbital motion to numerically integrate Cowell's form of the system of differential equations. Shadow conditions are predicted by embedding this integrator within Brent s method for finding the root of a nonlinear equation. The IRIS_EFT software models the effects of the following types of orbit perturbations on the long-term evolution and shadow characteristics of IRIS mission orbits. (1) Non-spherical Earth gravity, (2) Atmospheric drag, (3) Point-mass gravity of the Sun, and (4) Point-mass gravity of the Moon. The objective of this effort was to create an in-house computer program that would perform eclipse-free-time analysis. of candidate IRIS spacecraft mission orbits in an accurate and timely fashion. The software is a suite of Fortran subroutines and data files organized as a "computational" engine that is used to accurately predict the long-term orbit evolution of IRIS mission orbits while searching for Earth shadow conditions.
Parker, V J; Harjes, L M; Dembek, K; Young, G S; Chew, D J; Toribio, R E
2017-05-01
Hypovitaminosis D is associated with progression of renal disease, development of renal secondary hyperparathyroidism (RHPT), chronic kidney disease-mineral bone disorder (CKD-MBD), and increased mortality in people with CKD. Despite what is known regarding vitamin D dysregulation in humans with CKD, little is known about vitamin D metabolism in dogs with CKD. The purpose of our study was to further elucidate vitamin D status in dogs with different stages of CKD and to relate it to factors that affect the development of CKD-MBD, including parathyroid hormone (PTH), fibroblast growth factor-23 (FGF-23), calcium, and phosphorus concentrations. Thirty-seven dogs with naturally occurring CKD were compared to 10 healthy dogs. Serum 25-hydroxyvitamin D [25(OH)D], 1,25-dihydroxyvitamin D [1,25(OH) 2 D], and 24,25-dihydroxyvitamin D [24,25(OH) 2 D], and PTH and FGF-23 concentrations were measured. Their association with serum calcium and phosphorus concentrations and IRIS stage was determined. Compared to healthy dogs, all vitamin D metabolite concentrations were significantly lower in dogs with International Renal Interest Society (IRIS) stages 3 and 4 CKD (r [creatinine]: -0.49 to -0.60; P < .05) but not different in dogs with stages 1 and 2 CKD. All vitamin D metabolites were negatively correlated with PTH, FGF-23, and phosphorus concentrations (r: -0.39 to -0.64; P < .01). CKD in dogs is associated with decreases in all vitamin D metabolites evaluated suggesting that multiple mechanisms, in addition to decreased renal mass, affect their metabolism. This information could have prognostic and therapeutic implications. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
NASA Technical Reports Server (NTRS)
Red, Michael T.; Hess, Philip W.
1989-01-01
Among the Lyndon B. Johnson Space Center's responsibilities for Space Station Freedom is the cupola. Attached to the resource node, the cupola is a windowed structure that will serve as the space station's secondary control center. From the cupola, operations involving the mobile service center and orbital maneuvering vehicle will be conducted. The Systems Engineering Simulator (SES), located in building 16, activated a real-time man-in-the-loop cupola simulator in November 1987. The SES cupola is an engineering tool with the flexibility to evolve in both hardware and software as the final cupola design matures. Two workstations are simulated with closed-circuit television monitors, rotational and translational hand controllers, programmable display pushbuttons, and graphics display with trackball and keyboard. The displays and controls of the SES cupola are driven by a Silicon Graphics Integrated Raster Imaging System (IRIS) 4D/70 GT computer. Through the use of an interactive display builder program, SES, cupola display pages consisting of two dimensional and three dimensional graphics are constructed. These display pages interact with the SES via the IRIS real-time graphics interface. The focus is on the real-time graphics interface applications software developed on the IRIS.
Iris recognition based on robust principal component analysis
NASA Astrophysics Data System (ADS)
Karn, Pradeep; He, Xiao Hai; Yang, Shuai; Wu, Xiao Hong
2014-11-01
Iris images acquired under different conditions often suffer from blur, occlusion due to eyelids and eyelashes, specular reflection, and other artifacts. Existing iris recognition systems do not perform well on these types of images. To overcome these problems, we propose an iris recognition method based on robust principal component analysis. The proposed method decomposes all training images into a low-rank matrix and a sparse error matrix, where the low-rank matrix is used for feature extraction. The sparsity concentration index approach is then applied to validate the recognition result. Experimental results using CASIA V4 and IIT Delhi V1iris image databases showed that the proposed method achieved competitive performances in both recognition accuracy and computational efficiency.
2-(2-Methyl-4-chlorophenoxy)propionic acid (MCPP)
Integrated Risk Information System (IRIS)
2 - ( 2 - Methyl - 4 - chlorophenoxy ) propionic acid ( MCPP ) ; CASRN 93 - 65 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( H
Retrospective Evaluation of Topical Bimatoprost and Iris Pigmentation Change.
Zaleski-Larsen, Lisa A; Ruth, Nadine H; Fabi, Sabrina G
2017-12-01
Topical bimatoprost is a topical prostaglandin analog originally used to treat glaucoma and more recently used to cosmetically induce hypertrichosis of the eyelashes. Iris pigmentation change has been noted in the treatment of glaucoma but has not been assessed with the cosmetic periorbital application of bimatoprost. To evaluate for iris pigmentation change with the long-term cosmetic use of topical bimatoprost. A retrospective chart review in a cosmetic dermatology practice of women (N = 50) who consistently purchased topical bimatoprost over an average of 4.59 years was compared with that of age-matched non-bimatoprost patients (N = 50). A blinded evaluator assessed each patient for iris pigmentary change. No iris pigmentation change was noted with the cutaneous application of bimatoprost. The cutaneous application of bimatoprost appears to be safe with minimal risk for iris pigmentation change.
Ratnam, I; Chiu, C; Kandala, N-B; Easterbrook, P J
2006-02-01
It is estimated that 10%-25% of patients who start highly active antiretroviral therapy (HAART) experience immune reconstitution inflammatory syndrome (IRIS). Our objective was to determine the incidence, clinical spectrum, and predictors of IRIS in an ethnically diverse cohort of patients initiating HAART. A retrospective study of all patients starting HAART between 1 January 2000 and 31 August 2002 at a human immunodeficiency virus (HIV) clinic in London was performed. All laboratory measurements and data on antiretroviral therapies were obtained from the clinic database. Medical records were reviewed to identify clinical events consistent with IRIS during the 6 months after HAART was initiated. A total of 199 patients were included, of whom 50.8% were male, 59.3% were black African, 29.1% were white, and 10.5% were black Caribbean. The median baseline CD4 cell count and HIV RNA load were 174x10(6) cells/L (interquartile range [IQR], 82-285x10(6) cells/L) and 37,830 copies/mL (IQR, 4809-149,653 copies/mL), respectively. Forty-four patients (22.7%) experienced an IRIS event at a median of 12 weeks after HAART initiation (IQR, 4-24 weeks after initiation); 22 events (50%) involved genital herpes, 10 (23%) involved genital warts, 4 (9.0%) involved molluscum contagiosum, and 4 (9.0%) involved varicella zoster virus infection. Five patients had mycobacterial infections, 4 had hepatitis B, 1 had Pneumocystis jirovecci infection, and 1 had Kaposi sarcoma. The strongest independent predictors of IRIS were younger age at initiation of HAART (P=.003), baseline CD4 cell percentage of <10% (odds ratio [OR], 2.97; IQR, 1.17-7.55) compared with >15%, and ratio of CD4 cell percentage to CD8 cell percentage of <0.15 (OR, 3.45; 95% confidence interval, 1.27-9.1) compared with >0.3. Approximately one-quarter of patients who start HAART experience an IRIS event. The majority are dermatological, in particular genital herpes and warts. Patients with advanced immunodeficiency at HAART initiation are at greatest risk of developing IRIS and should be appropriately screened and monitored.
Feature and Score Fusion Based Multiple Classifier Selection for Iris Recognition
Islam, Md. Rabiul
2014-01-01
The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al. PMID:25114676
Feature and score fusion based multiple classifier selection for iris recognition.
Islam, Md Rabiul
2014-01-01
The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.
Quantitative study of the microvasculature and its endothelial cells in the porcine iris.
Yang, Hongfang; Yu, Paula K; Cringle, Stephen J; Sun, Xinghuai; Yu, Dao-Yi
2015-03-01
The roles of the iris microvasculature have been increasingly recognised in the pathogenesis of glaucoma and cataract; however limited information exists regarding the iris microvasculature and its endothelium. This study quantitatively assessed the iris microvascular network and its endothelium using intra-luminal micro-perfusion, fixation, and staining of the porcine iris. The temporal long posterior ciliary artery of 11 isolated porcine eyes was cannulated, perfusion-fixed and labelled using silver nitrate. The iris microvasculature was studied for its distribution, orders and endothelial morphometrics. The density of three layers of microvasculature was measured. Endothelial cell length and width were measured for each vessel order. The iris has an unusual vascular distribution which consisted of abundant large vessels in the middle of the iris stroma, branching over a relatively short distance to the microvasculature located in the superficial and deep stroma as well as the pupil edge. The average vascular density of the middle, superficial, and deep layers were 38.9 ± 1.93%, 10.9 ± 1.61% and 8.0 ± 0.79% respectively. Multiple orders of iris vessels (capillary, 6 orders of arteries, and 4 orders of veins) with relatively large capillary and input arteries (319.5 ± 25.6 μm) were found. Significant heterogeneity of vascular diameter and shape of the endothelia was revealed in different orders of the iris vasculature. Detailed information of topography and endothelium of the iris microvasculature combined with unique structural features of the iris may help us to further understand the physiological and pathogenic roles of the iris in relevant ocular diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lippi, Ilaria; Perondi, F; Meucci, V; Mannarini, C; Intorre, L; Guidi, G
2017-09-01
The aim of the present study was to investigate retrospectively the plasma concentration of alpha-tocopherol in dogs with naturally acquired chronic kidney disease (CKD), at different stages of severity. Forty dogs (CKD group) with different stages of CKD (IRIS 1 n=12, IRIS 2 n=8, IRIS 3 n=11, IRIS 4 n=9) and 20 clinically healthy dogs were considered. Plasma alpha-tocopherol was assessed in both groups through high performance liquid chromatography (HPLC). Dogs of CKD group showed significantly lower (p=0.0002) levels of plasma alpha-tocopherol compared with clinically healthy dogs. A significant difference (p<0.04) in the number of patients with plasma alpha-tocopherol > or ≤ 21.5 ppm was found in CKD patients at different stages of severity. No significant correlation between plasma levels of alpha-tocopherol and plasma creatinine was found. In the present study, dogs affected by spontaneous CKD showed significantly lower plasma concentrations of alpha-tocopherol compared with clinically healthy dogs. Plasma alpha-tocopherol deficiency seems to be more severe in IRIS stage 1 and 4, compared with IRIS stage 2 and 3. The finding of marked alpha-tocopherol deficiency in patients in IRIS stage 1 should encourage further studies on the early use of prescription renal diet and antioxidant in this group of patients.
IRIS Toxicological Review of Pentabromodiphenyl Ether (Final Report)
The purpose of this Toxicological Review is to provide scientific support and rationale for the hazard and dose-response assessment in IRIS pertaining to chronic exposure to 2,2',4,4',5-pentabromodiphenyl ether. It is not intended to be a comprehensive treatise on the chemical...
IRIS Toxicological Review of 1,4-Dioxane (with Inhalation Update) (External Review Draft)
EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-Dioxane (with inhalation update) that when finalized will appear on the Integrated Risk Information System (IRIS) database.
2,4-/2,6-Toluene diisocyanate mixture (TDI)
Integrated Risk Information System (IRIS)
2,4 - / 2,6 - Toluene diisocyanate mixture ( TDI ) ; CASRN 26471 - 62 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Haz
RIP-REMOTE INTERACTIVE PARTICLE-TRACER
NASA Technical Reports Server (NTRS)
Rogers, S. E.
1994-01-01
Remote Interactive Particle-tracing (RIP) is a distributed-graphics program which computes particle traces for computational fluid dynamics (CFD) solution data sets. A particle trace is a line which shows the path a massless particle in a fluid will take; it is a visual image of where the fluid is going. The program is able to compute and display particle traces at a speed of about one trace per second because it runs on two machines concurrently. The data used by the program is contained in two files. The solution file contains data on density, momentum and energy quantities of a flow field at discrete points in three-dimensional space, while the grid file contains the physical coordinates of each of the discrete points. RIP requires two computers. A local graphics workstation interfaces with the user for program control and graphics manipulation, and a remote machine interfaces with the solution data set and performs time-intensive computations. The program utilizes two machines in a distributed mode for two reasons. First, the data to be used by the program is usually generated on the supercomputer. RIP avoids having to convert and transfer the data, eliminating any memory limitations of the local machine. Second, as computing the particle traces can be computationally expensive, RIP utilizes the power of the supercomputer for this task. Although the remote site code was developed on a CRAY, it is possible to port this to any supercomputer class machine with a UNIX-like operating system. Integration of a velocity field from a starting physical location produces the particle trace. The remote machine computes the particle traces using the particle-tracing subroutines from PLOT3D/AMES, a CFD post-processing graphics program available from COSMIC (ARC-12779). These routines use a second-order predictor-corrector method to integrate the velocity field. Then the remote program sends graphics tokens to the local machine via a remote-graphics library. The local machine interprets the graphics tokens and draws the particle traces. The program is menu driven. RIP is implemented on the silicon graphics IRIS 3000 (local workstation) with an IRIX operating system and on the CRAY2 (remote station) with a UNICOS 1.0 or 2.0 operating system. The IRIS 4D can be used in place of the IRIS 3000. The program is written in C (67%) and FORTRAN 77 (43%) and has an IRIS memory requirement of 4 MB. The remote and local stations must use the same user ID. PLOT3D/AMES unformatted data sets are required for the remote machine. The program was developed in 1988.
Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors
Skalet, Alison H.; Li, Yan; Lu, Chen D.; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G.; Thomas, Charles R.; Huang, David
2016-01-01
Objective To evaluate tumor vasculature with optical coherence tomography (OCT) angiography (OCTA) in malignant iris melanomas and benign iris lesions. Design Cross-sectional observational clinical study. Participants Patients with iris lesions and healthy volunteers. Methods Eyes were imaged using OCTA systems operating at 1050 and 840 nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanomas patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. Main Outcome Measures OCT and OCTA images, qualitative evaluation of iris and tumor vasculature and quantitative vessel density. Results One eye each of eight normal volunteers and nine patients with iris melanomas or benign iris lesions including freckles, nevi, and an iris pigment epithelial (IPE) cyst were imaged. The normal iris has radially-oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In two eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, p<0.05) than in benign iris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050 nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% participants in whom imaging was attempted. Conclusions This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no-injection, cost-effective method for monitoring a variety of tumors including iris melanocytic lesions for growth and vascularity. This could be helpful in evaluating tumors for malignant transformation and response to treatment. Penetration of the OCT beam remains a limitation for highly pigmented tumors, as does the inability to image the entire iris in a single field. PMID:27856029
Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors.
Skalet, Alison H; Li, Yan; Lu, Chen D; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G; Thomas, Charles R; Huang, David
2017-02-01
To evaluate tumor vasculature with optical coherence tomography angiography (OCTA) in malignant iris melanomas and benign iris lesions. Cross-sectional observational clinical study. Patients with iris lesions and healthy volunteers. Eyes were imaged using OCTA systems operating at 1050- and 840-nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanoma patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. OCT and OCTA images, qualitative evaluation of iris and tumor vasculature, and quantitative vessel density. One eye each of 8 normal volunteers and 9 patients with iris melanomas or benign iris lesions, including freckles, nevi, and an iris pigment epithelial (IPE) cyst, were imaged. The normal iris has radially oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In 2 eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, P < 0.05) than in benign iris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050-nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% of participants in whom imaging was attempted. This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no-injection, cost-effective method for monitoring a variety of tumors, including iris melanocytic lesions, for growth and vascularity. This could be helpful in evaluating tumors for malignant transformation and response to treatment. Penetration of the OCT beam remains a limitation for highly pigmented tumors, as does the inability to image the entire iris in a single field. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Antoniazzi, Carolina Elizabet; López, Javier Alejandro; Duré, Marta; Falico, Diego Alejandro
2013-06-01
Feeding of two amphibian species (Anura: Hylidae) during the low temperatures season and its relationship with energy storage in Santa Fe, Argentina. In environments with thermal and pluvial seasonality such as those of the Middle Paraná River floodplain (Province of Santa Fe, Argentina), most amphibian species reproduce during the warm season and drastically diminish their activity during winter. Even though, a few species remain active during the cold season, such as Hypsiboas pulchellus that has its reproductive peak during the autumn-winter period (and the consequent energy demand). The objective of this study was to analyze and compare the feeding and development of fat bodies during the low temperature season for H. pulchellus and Dendropsophus nanus. We analyzed entire gastrointestinal tract contents of both species (H. pulchellus = 110 specimens; D. nanus = 114 specimens) and applied an index (IRI%) that combines prey abundance, volume and frequency to describe frogs diets; we used fat bodies weights as indicators of stored energy reserves. We compared diet between species with a niche overlap index (Ojk: 0-1) and used null models to ascribe statistical significance to evaluate overlap; and we analyzed variation in empty guts proportions through months and between species. Also, using ANCOVAs we explored differences in fat bodies, number and volume of prey consumed along months, between species and sexes. The most important preys in H. pulchellus diet during the cold season were Araneae (IRI% = 34.96), Chironomidae (IRI% = 33.08), Tipulidae (IRI% = 11.44) and Gryllidae (IR1% = 7.31); while for D. nanus, Chironomidae (IR1% = 48.14), Tipulidae (IRI% = 18.41), Psychodidae (IRI% = 7.44) and Araneae (IRI% = 7.34). Diet overlap between species was elevated (Ojk=0.78) and higher than expected by chance (mean simulated indices: Ojk = 0.04; p[observed > or = expected]<0.01; p[observed < or = expected] = 1). In H. pulchellus there was a monthly variation in number of prey per gut, while in D. nanus there was a difference in fat bodies development between sexes. Fat bodies development, number of prey per gut and preys volume also varied between species. Despite diet similarity between H. pulchellus and D. nanus, each species showed a different strategy to accumulate energy and support their activity during the cold season. The low rate of gastrointestinal emptiness in H. pulchellus (< 10% in any analyzed month) together with the poor development of their fat bodies, allows us to point out that, to sustain the breeding elevated energy demands, this species continues with a high feeding rate even at the low temperatures of cold season. On the other hand, the rate of gastrointestinal emptiness of D. nanus was higher than that of H. pulchellus (May = 17.24%, July = 22.22% and August = 35.71%), while their fat bodies were well developed. Thus, D. nanus would depend more on their stored reserves to sustain the energy demands of being active during the low temperatures season and hence would reach the reproductive season in spring-summer in good body condition.
Zhai, Yuan; Shen, Xiu-da; Hancock, Wayne W; Gao, Feng; Qiao, Bo; Lassman, Charles; Belperio, John A; Strieter, Robert M; Busuttil, Ronald W; Kupiec-Weglinski, Jerzy W
2006-05-15
Ischemia-reperfusion injury (IRI), an innate immune-dominated inflammatory response, develops in the absence of exogenous Ags. The recently highlighted role of T cells in IRI raises a question as to how T lymphocytes interact with the innate immune system and function with no Ag stimulation. This study dissected the mechanism of innate immune-induced T cell recruitment and activation in rat syngeneic orthotopic liver transplantation (OLT) model. Liver IRI was induced after cold storage (24-36 h) at 4 degrees C in University of Wisconsin solution. Gene products contributing to IRI were identified by cDNA microarray at 4-h posttransplant. IRI triggered increased intrahepatic expression of CXCL10, along with CXCL9 and 11. The significance of CXCR3 ligand induction was documented by the ability of neutralizing anti-CXCR3 Ab treatment to ameliorate hepatocellular damage and improve 14-day survival of 30-h cold-stored OLTs (95 vs 40% in controls; p < 0.01). Immunohistology analysis confirmed reduced CXCR3+ and CD4+ T cell infiltration in OLTs after treatment. Interestingly, anti-CXCR3 Ab did not suppress innate immune activation in the liver, as evidenced by increased levels of IL-1beta, IL-6, inducible NO synthase, and multiple neutrophil/monokine-targeted chemokine programs. In conclusion, this study demonstrates a novel mechanism of T cell recruitment and function in the absence of exogenous Ag stimulation. By documenting that the execution of innate immune function requires CXCR3+CD4+ T cells, it highlights the critical role of CXCR3 chemokine biology for the continuum of innate to adaptive immunity in the pathophysiology of liver IRI.
Parallel ALLSPD-3D: Speeding Up Combustor Analysis Via Parallel Processing
NASA Technical Reports Server (NTRS)
Fricker, David M.
1997-01-01
The ALLSPD-3D Computational Fluid Dynamics code for reacting flow simulation was run on a set of benchmark test cases to determine its parallel efficiency. These test cases included non-reacting and reacting flow simulations with varying numbers of processors. Also, the tests explored the effects of scaling the simulation with the number of processors in addition to distributing a constant size problem over an increasing number of processors. The test cases were run on a cluster of IBM RS/6000 Model 590 workstations with ethernet and ATM networking plus a shared memory SGI Power Challenge L workstation. The results indicate that the network capabilities significantly influence the parallel efficiency, i.e., a shared memory machine is fastest and ATM networking provides acceptable performance. The limitations of ethernet greatly hamper the rapid calculation of flows using ALLSPD-3D.
IRIS Toxicological Review of Vanadium Pentoxide ...
On September 30, 2011, the draft Toxicological Review of Vanadium Pentoxide and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process (May 2009), introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Vanadium Pentoxide and the charge to external peer reviewers are posted on this site. EPA is reassessing its IRIS toxicological review of vanadium pentoxide (CASRN 1314-62-1). This vanadium pentoxide reassessment consists of an oral reference dose (RfD), an inhalation reference concentration (RfC), an inhalation unit risk (IUR) and a cancer weight of evidence descriptor. This is the first assessment developing an RfC or IUR for this compound. This assessment is intended to provide human health data to support agency regulatory decisions.
Um, Jae-Young; An, Nyeon-Hyoung; Yang, Gui-Bi; Lee, Geon-Mok; Cho, Ju-Jang; Cho, Jae-Woon; Hwang, Woo-Jun; Chae, Han-Jung; Kim, Hyung-Ryong; Hong, Seung-Heon; Kim, Hyung-Min
2005-01-01
Iridology is the study of the iris of the eye to detect the conditions of the body and its organs, genetic strengths and weaknesses, etc. Although iridology is not widely used as a scientific tool for healthcare professionals to get to the source of people's health conditions, it has been used as a supplementary source to help the diagnosis of medical conditions by noting irregularities of the pigmentation in the iris among some Korean Oriental medical doctors. Angiotensin converting enzyme (ACE) gene polymorphism is one of the most well studied genetic markers of vascular disease. We investigated the relationship between iridological constitution and ACE polymorphism in hypertensives. We classified 87 hypertensives and 79 controls according to iris constitution and determined the ACE genotype of each individual. DD genotype was more prevalent in patients with a neurogenic constitution than in controls. This finding supports the hypothesis that D allele is a candidate gene for hypertension and demonstrates the association among ACE genotype, Korean hypertensives and iris constitution.
Specification of ISS Plasma Environment Variability
NASA Technical Reports Server (NTRS)
Minow, Joseph I.; Neergaard, Linda F.; Bui, Them H.; Mikatarian, Ronald R.; Barsamian, H.; Koontz, Steven L.
2004-01-01
Quantifying spacecraft charging risks and associated hazards for the International Space Station (ISS) requires a plasma environment specification for the natural variability of ionospheric temperature (Te) and density (Ne). Empirical ionospheric specification and forecast models such as the International Reference Ionosphere (IRI) model typically only provide long term (seasonal) mean Te and Ne values for the low Earth orbit environment. This paper describes a statistical analysis of historical ionospheric low Earth orbit plasma measurements from the AE-C, AE-D, and DE-2 satellites used to derive a model of deviations of observed data values from IRI-2001 estimates of Ne, Te parameters for each data point to provide a statistical basis for modeling the deviations of the plasma environment from the IRI model output. Application of the deviation model with the IRI-2001 output yields a method for estimating extreme environments for the ISS spacecraft charging analysis.
On September 9, 2011, the Toxicological Review of 1,4-Dioxane (inhalation) (External Review Draft) was posted for external peer review and public comment. Subsequently, the Toxicological Review and IRIS Summary were reviewed internally by EPA and by other federal agencies and Exe...
Full 3D Analysis of the GE90 Turbofan Primary Flowpath
NASA Technical Reports Server (NTRS)
Turner, Mark G.
2000-01-01
The multistage simulations of the GE90 turbofan primary flowpath components have been performed. The multistage CFD code, APNASA, has been used to analyze the fan, fan OGV and booster, the 10-stage high-pressure compressor and the entire turbine system of the GE90 turbofan engine. The code has two levels of parallel, and for the 18 blade row full turbine simulation has 87.3 percent parallel efficiency with 121 processors on an SGI ORIGIN. Grid generation is accomplished with the multistage Average Passage Grid Generator, APG. Results for each component are shown which compare favorably with test data.
Aptel, Florent; Beccat, Sylvain; Fortoul, Vincent; Denis, Philippe
2011-08-01
To compare anterior chamber volume (ACV), iris volume, and iridolenticular contact (ILC) area before and after laser peripheral iridotomy (LPI) in eyes with pigment dispersion syndrome (PDS) using anterior segment optical coherence tomography (AS OCT) and image processing software. Cross-sectional study. Eighteen eyes of 18 patients with PDS; 30 eyes of 30 controls matched for age, gender, and refraction. Anterior segment OCT imaging was performed in all eyes before LPI and 1, 4, and 12 weeks after LPI. At each visit, 12 cross-sectional images of the AS were taken: 4 in bright conditions with accommodation (accommodation), 4 in bright conditions without accommodation (physiological miosis), and 4 under dark conditions (physiologic mydriasis). Biometric parameters were estimated using AS OCT radial sections and customized image-processing software. Anterior chamber volume, iris volume-to-length ratio, ILC area, AS OCT anterior chamber depth, and A-scan ultrasonography axial length. Before LPI, PDS eyes had a significantly greater ACV and ILC area than control eyes (P<0.01) and a significantly smaller iris volume-to-length ratio than the controls (P<0.05). After LPI, ACV and ILC area decreased significantly in PDS eyes, but iris volume-to-length ratio increased significantly (P<0.02) and was not significantly different from that of controls. These biometric changes were stable over time. Iris volume-to-length ratio decreased significantly from accommodation to mydriasis and from miosis to mydriasis, both in PDS and control eyes (P<0.01). In PDS eyes, ILC area decreased significantly from accommodation to mydriasis, both before and after LPI (P<0.01). On multivariate analysis, greater anterior chamber (AC) volume (P<0.02) and larger AC depth (P<0.05) before LPI were significant predictors of a larger ILC area. Pigment dispersion syndrome eyes do not have an iris that is abnormally large, relative to the AS size, but have a weakly resistant iris that is stretched and pushed against the lens when there is a pressure difference across the iris. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Liu, Lin; Sun, Qinglei; Wang, Ruobing; Chen, Zeli; Wu, Jiangchun; Xia, Fangzhou; Fan, Xian-Qun
2016-09-01
Retinal ischemia/reperfusion injury (IRI) may cause incurable visual impairment due to neural regeneration limits. Methane was shown to exert a protective effect against IRI in many organs. This study aims to explore the possible protective effects of methane-rich saline against retinal IRI in rat. Retinal IRI was performed on the right eyes of male Sprague-Dawley rats, which were immediately injected intraperitoneally with methane-saturated saline (25ml/kg). At one week after surgery, the number of retinal ganglion cells (RGCs), total retinal thickness, visual function were measured by hematoxylin and eosin staining, FluoroGold anterograde labeling and flash visual evoked potentials. The levels of 8-hydroxy-2-deoxyguanosine (8-OHdG), 4-Hydroxy-2-nonenal (4-HNE), malondialdehyde (MDA), superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GPx), caspase-3, caspase-9, B cell lymphoma/leukemia-2 (Bcl-2) and Bcl-2 associated X protein (Bax) in retinas were assessed by immunofluorescence staining, enzyme-linked immunosorbent assay and quantitative polymerase chain reaction. As expected, methane treatment significantly improved the retinal IRI-induced RGC loss, total retinal layer thinning and visual dysfunction. Moreover, methane treatment significantly reduced the levels of oxidative stress biomarkers (8-OHdG, 4-HNE, MDA) and increased the antioxidant enzyme activities (SOD, CAT, GPx) in the retinas with IRI. Meanwhile, methane treatment significantly increased the anti-apoptotic gene (Bcl-2) expression and decreased the pro-apoptotic gene (Bax) expression, accompanied by the suppression of caspase-3 and caspase-9 activity. Thus, these data demonstrated that methane can exert a neuroprotective role against retinal IRI through anti-oxidative and anti-apoptotic pathways. Copyright © 2016. Published by Elsevier B.V.
Differential Effects of RET and TRKB on Axonal Branching and Survival of Parasympathetic Neurons
Simpson, Julie; Keefe, Julie; Nishi, Rae
2014-01-01
Interactions between neurons and their targets of innervation influence many aspects of neural development. To examine how synaptic activity interacts with neurotrophic signaling, we determined the effects of blocking neuromuscular transmission on survival and axonal outgrowth of ciliary neurons from the embryonic chicken ciliary ganglion. Ciliary neurons undergo a period of cell loss due to programmed cell death between embryonic Days (E) 8 and 14 and they innervate the striated muscle of the iris. The nicotinic antagonist d-tubocurarine (dTC) induces an increase in branching measured by counting neurofilament-positive voxels (NF-VU) in the iris between E14–17 while reducing ciliary neuron survival. Blocking ganglionic transmission with dihyro-β-erythroidin and α-methyllycacontine does not mimic dTC. At E8, many trophic factors stimulate neurite outgrowth and branching of neurons placed in cell culture; however, at E13, only GDNF stimulates branching selectively in cultured ciliary neurons. The GDNF-induced branching at E13 could be inhibited by BDNF. Blocking ret signaling in vivo with a dominant negative (dn)ret decreases survival of ciliary and choroid neurons at E14 and prevents dTC induced increases in NF-VU in the iris at E17. Blocking TRKB signaling with dn TRKB increases NF-VU in the iris at E17 and decreases neuronal survival at E17, but not at E14. Thus, RET promotes survival during programmed cell death in the ciliary ganglion and contributes to promoting branching when synaptic transmission is blocked while TRKB inhibits branching and promotes maintenance of neuronal survival. These studies highlight the multifunctional nature of trophic molecule function during neuronal development. PMID:22648743
Haddow, Lewis J; Sahid, Faieza; Moosa, Mahomed-Yunus S
2008-07-01
Atypical manifestations of Cryptococcus neoformans disease have been reported in patients with HIV-1 infection as part of the spectrum of the immune reconstitution inflammatory syndrome (IRIS). We describe a cryptococcal breast abscess in a patient presenting after 11 months of highly active antiretroviral therapy (HAART). The arguments for and against the case being a novel manifestation of IRIS are discussed. The potential hazards of using CD4 count as a surrogate marker of IRIS and the danger of misdiagnosing IRIS as failure of HAART are highlighted.
Chlorine toxicity to early life stages of freshwater mussels (Bivalvia: Unionidae)
Valenti, T.W.; Cherry, D.S.; Currie, R.J.; Neves, R.J.; Jones, J.W.; Mair, R.; Kane, C.M.
2006-01-01
Chlorine (Cl) is a highly toxic, widely used halogen disinfectant that is present in point-source pollution discharges from wastewater treatment plants and industrial facilities. The U.S. Environmental Protection Agency freshwater criteria for Cl are 19 ??g total residual Cl (TRC)/L as a maximum 1-h average concentration and 11 ??g TRC/L as a maximum 4-d average; however, toxicological data for unionids were not used in these calculations. To address this void in the data, we conducted acute tests with glochidia from several species and 21-d bioassays with three-month-old Epioblasma capsaeformis and three-, six-, and 12-month-old Villosa iris juveniles. The 24-h lethal concentration 50 values for glochidia were between 70 and 220 ??g TRC/L, which are 2.5 to 37 times higher than those reported in other studies for cladocerans. Significant declines in growth and survivorship were observed in the 21-d test with E. capsaeformis at 20 ??g TRC/L. Lowest-observed-adverse- effects concentrations in bioassays with juvenile V. iris were higher (30-60 ??g TRC/L) but showed a significant trend of declining toxicity with increased age. Although endpoints were above water quality criteria, the long life spans of unionids and potential implications of chronic exposure to endangered juvenile mussels still warrant concern. ?? 2006 SETAC.
Prominence and tornado dynamics observed with IRIS and THEMIS
NASA Astrophysics Data System (ADS)
Schmieder, Brigitte; Levens, Peter; Labrosse, Nicolas; Mein, Pierre; Lopez Ariste, Arturo; Zapior, Maciek
2017-08-01
Several prominences were observed during campaigns in September 2013 and July 2014 with the IRIS spectrometer and the vector magnetograph THEMIS (Tenerife). SDO/AIA and IRIS provided images and spectra of prominences and tornadoes corresponding to different physical conditions of the transition region between the cool plasma and the corona. The vector magnetic field was derived from THEMIS observations by using the He D3 depolarisation due to the magnetic field. The inversion code (PCA) takes into account the Hanle and Zeeman effects and allows us to compute the strength and the inclination of the magnetic field which is shown to be mostly horizontal in prominences as well as in tornadoes. Movies from SDO/AIA in 304 A and Hinode/SOT in Ca II show the highly dynamic nature of the fine structures. From spectra in Mg II and Si IV lines provided by IRIS and H-alpha observed by the Multi-channel Subtractive Double Pass (MSDP) spectrograph in the Meudon Solar Tower we derived the Doppler shifts of the fine structures and reconstructed the 3D structure of tornadoes. We conclude that the apparent rotation of AIA tornadoes is due to large-scale quasi-periodic oscillations of the plasma along more or less horizontal magnetic structures.
Face Recognition with the Karhunen-Loeve Transform
1991-12-01
anthropometry community? 1-2 Methodology As part of this thesis, face recognition software is developed on the Silicon Graphics 4D Personal Iris...the anthropometry community. Standards The most important performance criteria is classification accuracy which is the per- centage of correct...demonstrated by Tarr (24). Reconstructed Output Image yl y2 ... y64 16 hidden layer units xl x2 ... x64 Input 64 by 64 pixel Image Figure 2.6. After the
Quiroga, Maria Florencia; Angerami, Matias Tomas; Santucci, Natalia; Ameri, Diego; Francos, Jose Luis; Wallach, Jorge; Sued, Omar; Cahn, Pedro; Salomón, Horacio; Bottasso, Oscar
2012-01-01
Tuberculosis (TB) remains the most frequent cause of illness and death from an infectious agent, and its interaction with HIV has devastating effects. We determined plasma levels of dehydroepiandrosterone (DHEA), its circulating form DHEA-suphate (DHEA-s) and cortisol in different stages of M. tuberculosis infection, and explored their role on the Th1 and Treg populations during different scenarios of HIV-TB coinfection, including the immune reconstitution inflammatory syndrome (IRIS), a condition related to antiretroviral treatment. DHEA levels were diminished in HIV-TB and HIV-TB IRIS patients compared to healthy donors (HD), HIV+ individuals and HIV+ individuals with latent TB (HIV-LTB), whereas dehydroepiandrosterone sulfate (DHEA-s) levels were markedly diminished in HIV-TB IRIS individuals. HIV-TB and IRIS patients presented a cortisol/DHEA ratio significantly higher than HIV+, HIV-LTB and HD individuals. A positive correlation was observed between DHEA-s and CD4 count among HIV-TB individuals. Conversely, cortisol plasma level inversely correlated with CD4 count within HIV-TB individuals. M. tuberculosis-specific Th1 lymphocyte count was increased after culturing PBMC from HIV-TB individuals in presence of DHEA. We observed an inverse correlation between DHEA-s plasma level and Treg frequency in co-infected individuals, and CD4+FoxP3+ Treg frequency was increased in HIV-TB and IRIS patients compared to other groups. Strikingly, we observed a prominent CD4+CD25-FoxP3+ population across HIV-TB and HIV-TB IRIS patients, which frequency correlated with DHEA plasma level. Finally, DHEA treatment negatively regulated FoxP3 expression without altering Treg frequency in co-infected patients. These data suggest an enhancing role for DHEA in the immune response against M. tuberculosis during HIV-TB coinfection and IRIS.
Quiroga, Maria Florencia; Angerami, Matias Tomas; Santucci, Natalia; Ameri, Diego; Francos, Jose Luis; Wallach, Jorge; Sued, Omar; Cahn, Pedro; Salomón, Horacio; Bottasso, Oscar
2012-01-01
Tuberculosis (TB) remains the most frequent cause of illness and death from an infectious agent, and its interaction with HIV has devastating effects. We determined plasma levels of dehydroepiandrosterone (DHEA), its circulating form DHEA-suphate (DHEA-s) and cortisol in different stages of M. tuberculosis infection, and explored their role on the Th1 and Treg populations during different scenarios of HIV-TB coinfection, including the immune reconstitution inflammatory syndrome (IRIS), a condition related to antiretroviral treatment. DHEA levels were diminished in HIV-TB and HIV-TB IRIS patients compared to healthy donors (HD), HIV+ individuals and HIV+ individuals with latent TB (HIV-LTB), whereas dehydroepiandrosterone sulfate (DHEA-s) levels were markedly diminished in HIV-TB IRIS individuals. HIV-TB and IRIS patients presented a cortisol/DHEA ratio significantly higher than HIV+, HIV-LTB and HD individuals. A positive correlation was observed between DHEA-s and CD4 count among HIV-TB individuals. Conversely, cortisol plasma level inversely correlated with CD4 count within HIV-TB individuals. M. tuberculosis-specific Th1 lymphocyte count was increased after culturing PBMC from HIV-TB individuals in presence of DHEA. We observed an inverse correlation between DHEA-s plasma level and Treg frequency in co-infected individuals, and CD4+FoxP3+ Treg frequency was increased in HIV-TB and IRIS patients compared to other groups. Strikingly, we observed a prominent CD4+CD25-FoxP3+ population across HIV-TB and HIV-TB IRIS patients, which frequency correlated with DHEA plasma level. Finally, DHEA treatment negatively regulated FoxP3 expression without altering Treg frequency in co-infected patients. These data suggest an enhancing role for DHEA in the immune response against M. tuberculosis during HIV-TB coinfection and IRIS. PMID:22431997
Ku, Judy Y; Nongpiur, Monisha E; Park, Judy; Narayanaswamy, Arun K; Perera, Shamira A; Tun, Tin A; Kumar, Rajesh S; Baskaran, Mani; Aung, Tin
2014-12-01
To qualitatively analyze anterior chamber structures imaged by ultrasound biomicroscopy (UBM) in primary angle-closure patients. Subjects diagnosed as primary angle-closure suspect (PACS), primary angle-closure glaucoma (PACG), and previous acute primary angle closure (APAC) were recruited prospectively along with a group of normal controls. UBM was performed under standardized dark room conditions and qualitative assessment was carried out using a set of reference photographs of standard UBM images to categorize the various anatomic features related to angle configuration. These included overall and basal iris thicknesses, iris convexity, iris angulation, ciliary body size, and ciliary sulcus. A total of 60 PACS, 114 PACG, 41 APAC, and 33 normal controls were included. Patients were predominantly older Chinese females. After controlling the confounding effect of age and sex, eyes with overall thicker irides [medium odds ratio (OR) 3.58, thick OR 2.84] when compared with thin irides have a significantly higher likelihood of having PACS/PACG/APAC versus controls. Thicker basal iris component (medium OR 4.13, thick OR 3.39) also have higher likelihood of having angle closure when compared with thin basal iris thickness. Subjects with basal iris insertion, mild iris angulation, and large ciliary body have a higher OR of having angle closure. In contrast, the presence/absence of a ciliary sulcus did not influence the likelihood of angle closure. Eyes with thicker overall and basal iris thicknesses are more likely to have angle closure than controls. Other features that increase the likelihood of angle closure include basal iris insertion, mild iris angulation, and large ciliary body.
Kumar, Dhivya Ashok; Agarwal, Amar; Agarwal, Athiya; Chandrasekar, Radika; Priyanka, Vijetha
2015-01-01
Long-term assessment of the optic position of glued transscleral fixated intraocular lens (IOL) with optical coherence tomography (OCT). Prospective observational case series. Patients with a minimum 5 years' follow-up after glued IOL surgery were included. Postoperatively, IOL position was examined by anterior segment OCT (Carl Zeiss Meditec) and the scans were analyzed in 2 axes (180°-0° and 270°-90°) using MatLab (Mathworks). Best-corrected visual acuity (BCVA; Snellen's charts), Orbscan, retinoscopy, refraction, and slit-lamp biomicroscopy were performed. The distance between the iris margin and the anterior IOL optic (D1, D2), slope of the line across the iris and IOL, the slope ratio between the IOL and iris, IOL tilt, and optic surface changes were determined and correlated with the astigmatism and vision. A total of 60 eyes (mean follow-up of 5.9±0.2 years; range, 5-6 years) were evaluated. There was a significant correlation (P = 0.000) between the slope of iris and the IOL in horizontal and vertical axes. The mean D1 and D2 were 0.94 ± 0.36 and 0.95 ± 0.36 mm, respectively. Nine of 60 eyes (15%) had pigment dispersed on the IOL surface. Twenty-one eyes (35%) had optic tilt detected on OCT and 65% of eyes had no optic tilt. The mean angle between the IOL and the iris was noted to be 3.2 ± 2.7° and 2.9 ± 2.6° in horizontal and vertical axes, respectively. The mean ocular residual astigmatism (ORA) was 0.53 ± 0.5 diopters. There was no difference in the ORA between the eyes with and without tilt (P = 0.762). There was no correlation (P = 0.348) between the ORA and BCVA. Position of the IOL was not dependent on the type of lens, age of the patient, or the preoperative surgical indication. Long-term analysis with OCT demonstrated good IOL positioning without any significant optic tilt in patients with glued IOL fixation. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Unified framework for automated iris segmentation using distantly acquired face images.
Tan, Chun-Wei; Kumar, Ajay
2012-09-01
Remote human identification using iris biometrics has high civilian and surveillance applications and its success requires the development of robust segmentation algorithm to automatically extract the iris region. This paper presents a new iris segmentation framework which can robustly segment the iris images acquired using near infrared or visible illumination. The proposed approach exploits multiple higher order local pixel dependencies to robustly classify the eye region pixels into iris or noniris regions. Face and eye detection modules have been incorporated in the unified framework to automatically provide the localized eye region from facial image for iris segmentation. We develop robust postprocessing operations algorithm to effectively mitigate the noisy pixels caused by the misclassification. Experimental results presented in this paper suggest significant improvement in the average segmentation errors over the previously proposed approaches, i.e., 47.5%, 34.1%, and 32.6% on UBIRIS.v2, FRGC, and CASIA.v4 at-a-distance databases, respectively. The usefulness of the proposed approach is also ascertained from recognition experiments on three different publicly available databases.
IRIS Toxicological Review and Summary Documents for 1,4-Dichlorobenzene (External Peer Review)
The U.S. EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-dichlorobenzene that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used ...
IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR 2,2,4-TRIMETHYLPENTANE (EXTERNAL REVIEW DRAFT)
EPA has conducted a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 2,2,4-trimethylpentane, also called TMP, that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that scie...
NASA Technical Reports Server (NTRS)
Saini, Subhash; Frumkin, Michael; Hribar, Michelle; Jin, Hao-Qiang; Waheed, Abdul; Yan, Jerry
1998-01-01
Porting applications to new high performance parallel and distributed computing platforms is a challenging task. Since writing parallel code by hand is extremely time consuming and costly, porting codes would ideally be automated by using some parallelization tools and compilers. In this paper, we compare the performance of the hand written NAB Parallel Benchmarks against three parallel versions generated with the help of tools and compilers: 1) CAPTools: an interactive computer aided parallelization too] that generates message passing code, 2) the Portland Group's HPF compiler and 3) using compiler directives with the native FORTAN77 compiler on the SGI Origin2000.
PATHFINDER: Probing Atmospheric Flows in an Integrated and Distributed Environment
NASA Technical Reports Server (NTRS)
Wilhelmson, R. B.; Wojtowicz, D. P.; Shaw, C.; Hagedorn, J.; Koch, S.
1995-01-01
PATHFINDER is a software effort to create a flexible, modular, collaborative, and distributed environment for studying atmospheric, astrophysical, and other fluid flows in the evolving networked metacomputer environment of the 1990s. It uses existing software, such as HDF (Hierarchical Data Format), DTM (Data Transfer Mechanism), GEMPAK (General Meteorological Package), AVS, SGI Explorer, and Inventor to provide the researcher with the ability to harness the latest in desktop to teraflop computing. Software modules developed during the project are available in the public domain via anonymous FTP from the National Center for Supercomputing Applications (NCSA). The address is ftp.ncsa.uiuc.edu, and the directory is /SGI/PATHFINDER.
Compute Server Performance Results
NASA Technical Reports Server (NTRS)
Stockdale, I. E.; Barton, John; Woodrow, Thomas (Technical Monitor)
1994-01-01
Parallel-vector supercomputers have been the workhorses of high performance computing. As expectations of future computing needs have risen faster than projected vector supercomputer performance, much work has been done investigating the feasibility of using Massively Parallel Processor systems as supercomputers. An even more recent development is the availability of high performance workstations which have the potential, when clustered together, to replace parallel-vector systems. We present a systematic comparison of floating point performance and price-performance for various compute server systems. A suite of highly vectorized programs was run on systems including traditional vector systems such as the Cray C90, and RISC workstations such as the IBM RS/6000 590 and the SGI R8000. The C90 system delivers 460 million floating point operations per second (FLOPS), the highest single processor rate of any vendor. However, if the price-performance ration (PPR) is considered to be most important, then the IBM and SGI processors are superior to the C90 processors. Even without code tuning, the IBM and SGI PPR's of 260 and 220 FLOPS per dollar exceed the C90 PPR of 160 FLOPS per dollar when running our highly vectorized suite,
GNSS derived TEC data ingestion into IRI 2012
NASA Astrophysics Data System (ADS)
Migoya-Orué, Yenca; Nava, Bruno; Radicella, Sandro; Alazo-Cuartas, Katy
2015-04-01
Experimental vertical total electron content (VTEC) data given by Global Ionospheric Maps (GIM) has been ingested into the IRI version 2012, aiming to obtain grids of effective input parameter values that allow to minimize the difference between the experimental and modeled vertical TEC. Making use of the experience gained with the technique of model adaptation applied to NeQuick (Nava et al., 2005), it has been found possible to compute IRI world grids of effective ionosphere index parameters (IG). The IG grids thus obtained can be interpolated in space and time to calculate with IRI the 3D electron density at any location and also the TEC along any ground-to-satellite ray-path for a given epoch. In this study, the ingestion technique is presented and a posteriori validation, along with an assessment of the capability of the 'ingested' IRI to reproduce the ionosphere day-to-day foF2 variability during disturbed and quiet periods. The foF2 values retrieved are compared with data from about 20 worldwide ionosondes for selected periods of high (year 2000) and moderate to low solar activity (year 2006). It was found that the use of the ingestion scheme enhances the performance of the model when compared with its standard use based on solar activity drivers (R12 and F10.7), especially for high solar activity. As an example, the mean and standard deviation of the differences between experimental and reconstructed F2-peak values for April of year 2000 is 0.09 and 1.28 MHz for ingested IRI, compared to -0.81 and 1.27 MHz (IRI with R12 input) and -0.02 and 1.46 MHz (IRI with F10.7 input).
Fuel burnup analysis for IRIS reactor using MCNPX and WIMS-D5 codes
NASA Astrophysics Data System (ADS)
Amin, E. A.; Bashter, I. I.; Hassan, Nabil M.; Mustafa, S. S.
2017-02-01
International Reactor Innovative and Secure (IRIS) reactor is a compact power reactor designed with especial features. It contains Integral Fuel Burnable Absorber (IFBA). The core is heterogeneous both axially and radially. This work provides the full core burn up analysis for IRIS reactor using MCNPX and WIMDS-D5 codes. Criticality calculations, radial and axial power distributions and nuclear peaking factor at the different stages of burnup were studied. Effective multiplication factor values for the core were estimated by coupling MCNPX code with WIMS-D5 code and compared with SAS2H/KENO-V code values at different stages of burnup. The two calculation codes show good agreement and correlation. The values of radial and axial powers for the full core were also compared with published results given by SAS2H/KENO-V code (at the beginning and end of reactor operation). The behavior of both radial and axial power distribution is quiet similar to the other data published by SAS2H/KENO-V code. The peaking factor values estimated in the present work are close to its values calculated by SAS2H/KENO-V code.
Integrated Risk Information System (IRIS)
Trichlorofluoromethane ; CASRN 75 - 69 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinog
Integrated Risk Information System (IRIS)
Bromodichloromethane ; CASRN 75 - 27 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogen
NASA Astrophysics Data System (ADS)
Pignalberi, A.; Pezzopane, M.; Rizzi, R.; Galkin, I.
2018-01-01
The first part of this paper reviews methods using effective solar indices to update a background ionospheric model focusing on those employing the Kriging method to perform the spatial interpolation. Then, it proposes a method to update the International Reference Ionosphere (IRI) model through the assimilation of data collected by a European ionosonde network. The method, called International Reference Ionosphere UPdate (IRI UP), that can potentially operate in real time, is mathematically described and validated for the period 9-25 March 2015 (a time window including the well-known St. Patrick storm occurred on 17 March), using IRI and IRI Real Time Assimilative Model (IRTAM) models as the reference. It relies on foF2 and M(3000)F2 ionospheric characteristics, recorded routinely by a network of 12 European ionosonde stations, which are used to calculate for each station effective values of IRI indices IG_{12} and R_{12} (identified as IG_{{12{eff}}} and R_{{12{eff}}}); then, starting from this discrete dataset of values, two-dimensional (2D) maps of IG_{{12{eff}}} and R_{{12{eff}}} are generated through the universal Kriging method. Five variogram models are proposed and tested statistically to select the best performer for each effective index. Then, computed maps of IG_{{12{eff}}} and R_{{12{eff}}} are used in the IRI model to synthesize updated values of foF2 and hmF2. To evaluate the ability of the proposed method to reproduce rapid local changes that are common under disturbed conditions, quality metrics are calculated for two test stations whose measurements were not assimilated in IRI UP, Fairford (51.7°N, 1.5°W) and San Vito (40.6°N, 17.8°E), for IRI, IRI UP, and IRTAM models. The proposed method turns out to be very effective under highly disturbed conditions, with significant improvements of the foF2 representation and noticeable improvements of the hmF2 one. Important improvements have been verified also for quiet and moderately disturbed conditions. A visual analysis of foF2 and hmF2 maps highlights the ability of the IRI UP method to catch small-scale changes occurring under disturbed conditions which are not seen by IRI.
IRIS Toxicological Review of 1,4-Dioxane (with Inhalation ...
EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-Dioxane (with inhalation update) that when finalized will appear on the Integrated Risk Information System (IRIS) database. 1,4-Dioxane is commonly used as a solvent, cleaning agent, chemical stabilizer, surface coating, adhesive agent, and an ingredient in chemical manufacture.
1992-01-09
Herschfelder, J. 0., C . F. Curtis, and R. B. Bird, "Molecular Theory of Gases and Liquids", John Willey and Sons, New York, (1954), Chs. 7 and 8. 12...AL iryLt’ AND SLOTME 5- FUIING NUERS 1991 Sumn~er FAculty Resezrzi! ?ro-rz~ (SFBZF) Volne 2SbV0d. 4 F496202-4:4#- C -CO076 MtrGary_ Soore ___________ 7...Engineering Tools for Parallel Software Development Dr. John Antonio 2 (Report Not Available at this Time) Dr. Abdul Aziz Bhatti 3 A Taxonomy for
The Community-based Whole Magnetosphere Model
2011-11-15
magnetosphere to the IE module. These are used to specify the aurora. • Incorporated MSIS [Hedin, 1987] and IRI [Bil- itza, 2001] as empirical models...can actually be run utilizing MSIS and IRI at every time step, so they can be coupled like an upper atmosphere module. • Coupled the multifluid...J. L., and Gallagher, D. L.: Forma - tion of density troughs embedded in the outer plas- masphere by subauroral ion drift events, J. Geophys. Res., 102
Graphics and Flow Visualization of Computer Generated Flow Fields
NASA Technical Reports Server (NTRS)
Kathong, M.; Tiwari, S. N.
1987-01-01
Flow field variables are visualized using color representations described on surfaces that are interpolated from computational grids and transformed to digital images. Techniques for displaying two and three dimensional flow field solutions are addressed. The transformations and the use of an interactive graphics program for CFD flow field solutions, called PLOT3D, which runs on the color graphics IRIS workstation are described. An overview of the IRIS workstation is also described.
Characterization of (/sup 3/H)forskolin binding sites in the iris-ciliary body of the albino rabbit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldman, M.E.; Mallorga, P.; Pettibone, D.J.
1988-01-01
(/sup 3/H)forskolin binding sites were identified using membranes prepared from the iris-ciliary body of adult, albino rabbits. Scatchard analysis of saturation binding experiments demonstrated that (/sup 3/H)forskolin bound to a single population of high affinity sites. The K/sub d/ and B/sub max/ values were 8.7 +- 0.9 nM and 119.0 +- 30.9 fmolmg prot. using membranes prepared from frozen tissue and 17.0 +- 6.2 nM and 184.4 +- 47.2 fmolmg prot. using fresh tissue. The binding of (/sup 3/H)forskolin was magnesium-dependent. The B/sub max/ was enhanced by sodium fluoride and Gpp(NH)p, a nonhydrolyzable guanine nucleotide analog. Forskolin was the mostmore » potent inhibitor of (/sup 3/H)forskolin binding; two commercially-available analogs were weaker inhibitors. In an adenylate cyclase assay, there was the same rank order of potency to enhance enzyme activity. Based upon binding affinities, magnesium-dependence, sensitivity to sodium fluoride and Gpp(NH)p, rank order of potencies of analogs and correlation of binding with adenylate cyclase activity, these studies suggest that the (/sup 3/H)forskolin binding site in the iris-ciliary body is similar to the binding site in other tissues« less
SUMER-IRIS Observations of AR11875
NASA Astrophysics Data System (ADS)
Schmit, Donald; Innes, Davina
2014-05-01
We present results of the first joint observing campaign of IRIS and SOHO/SUMER. While the IRIS datasets provide information on the chromosphere and transition region, SUMER provides complementary diagnostics on the corona. On 2013-10-24, we observed an active region, AR11875, and the surrounding plage for approximately 4 hours using rapid-cadence observing programs. These datasets include spectra from a small C -class flare which occurs in conjunction with an Ellerman-bomb type event. Our analysis focusses on how the high spatial resolution and slit jaw imaging capabilities of IRIS shed light on the unresolved structure of transient events in the SUMER catalog.
Integrated Risk Information System (IRIS)
Rotenone ; CASRN 83 - 79 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effects )
Integrated Risk Information System (IRIS)
Mepiquat chloride ; CASRN 24307 - 26 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogen
Integrated Risk Information System (IRIS)
Chlorine dioxide ; CASRN 10049 - 04 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogeni
Integrated Risk Information System (IRIS)
Phenylmercuric acetate ; CASRN 62 - 38 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinog
Integrated Risk Information System (IRIS)
Fluridone ; CASRN 59756 - 60 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effec
Integrated Risk Information System (IRIS)
Asbestos ; CASRN 1332 - 21 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effects
Integrated Risk Information System (IRIS)
Quinone ; CASRN 106 - 51 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effects )
Integrated Risk Information System (IRIS)
Chloramben ; CASRN 133 - 90 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effect
Integrated Risk Information System (IRIS)
Integrated Risk Information System ( IRIS ) Chemical Assessment Summary U.S . Environmental Protection Agency National Center for Environmental Assessment Radium 226,228 ; CASRN 7440 - 14 - 4 , Human health assessment information on a chemical substance is included in the IRIS database only after a
Integrated Risk Information System (IRIS)
Silver ; CASRN 7440 - 22 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effects )
Integrated Risk Information System (IRIS)
Hexachlorophene ; CASRN 70 - 30 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Ef
Integrated Risk Information System (IRIS)
Antimony trioxide ; CASRN 1309 - 64 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogeni
Integrated Risk Information System (IRIS)
2 - Chloroacetophenone ; CASRN 532 - 27 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcino
Integrated Risk Information System (IRIS)
Ethylbenzene ; CASRN 100 - 41 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effe
Integrated Risk Information System (IRIS)
3 - Methylphenol ; CASRN 108 - 39 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic
Integrated Risk Information System (IRIS)
Aldicarb sulfone ; CASRN 1646 - 88 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic
Integrated Risk Information System (IRIS)
2 - Methoxyethanol ; CASRN 109 - 86 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogeni
Integrated Risk Information System (IRIS)
Selenourea ; CASRN 630 - 10 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effect
Integrated Risk Information System (IRIS)
Nitrapyrin ; CASRN 1929 - 82 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effec
Integrated Risk Information System (IRIS)
Carboxin ; CASRN 5234 - 68 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effects
Integrated Risk Information System (IRIS)
Chlorine cyanide ; CASRN 506 - 77 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic
Integrated Risk Information System (IRIS)
Glycidaldehyde ; CASRN 765 - 34 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Ef
Integrated Risk Information System (IRIS)
Disulfoton ; CASRN 298 - 04 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effect
Integrated Risk Information System (IRIS)
Ethyleneimine ; CASRN 151 - 56 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff
Pupillary Reconstruction and Outcome after Artificial Iris Implantation.
Mayer, Christian S; Reznicek, Lukas; Hoffmann, Andrea E
2016-05-01
Patients with iris defects suffer from severe visual impairment, especially increased glare sensitivity and cosmetic disturbances. This constitutes a great psychological strain for those patients. Until recently, possible treatment options were iris print contact lenses, sunglasses, and simple iris prostheses. The aim of this study was to investigate structural and functional outcome parameters and patient satisfaction after implantation of this new artificial iris prosthesis. Prospective case series investigating functional results and patient satisfaction after surgical iris reconstruction. Thirty-seven consecutive patients with traumatic iris defects presenting from 2011 through 2014 underwent pupillary reconstruction with a new artificial iris implant at the Department of Ophthalmology, Technical University Munich. The custom-made, flexible silicone iris prosthesis ArtificialIris (HumanOptics, Erlangen, Germany) used in this study is a novel and innovative device in the surgical treatment of iris defects. Patients were examined before and after iris reconstruction with the iris implant placed in the ciliary sulcus. Change of best-corrected visual acuity (BCVA), intraocular pressure (IOP), pupillary aperture, glare, contrast sensitivity, endothelial cell density, anterior chamber depth, anterior chamber angle, and patient satisfaction were assessed. Thirty-two eyes of 32 patients (mean age, 52.9±16.0 years) were included. After implantation and during follow-up, BCVA and IOP did not change significantly (BCVA, 0.77±0.62 logarithm of the minimum angle of resolution [logMAR] preoperatively vs. 0.68±0.64 logMAR 1 month postoperatively [P = 0.792]; IOP, 14.94±3.55 mmHg preoperatively vs. 17.72±5.88 mmHg 1 month postoperatively [P = 0.197]). The pupillary aperture was reduced significantly (42.11±20.1 mm(2) to 8.7±0.3 mm(2); P < 0.001). Contrast sensitivity increased significantly (0.80±0.51 to 0.93±0.49; P = 0.014). Endothelial cell count revealed a significant decrease postoperatively (1949±716 per 1 mm(2) to 1841±689 per 1 mm(2); P = 0.003). Anterior chamber depth (4.03±1.06 mm preoperatively vs. 4.29±0.70 mm postoperatively; P = 0.186) and angle (43.2±13.5° preoperatively vs. 40.5±10.8° postoperatively; P = 0.772) showed no significant differences. Subjective impairment through glare (9.12±1.62 preoperatively vs. 3.07±2.29 postoperatively; P < 0.001) and cosmetic disturbance (6.33±3.21 preoperatively vs. 1.58±0.86 postoperatively; P < 0.001) improved significantly. Patient satisfaction with the overall result was 8.91±1.51 of 10 points on an analog scale. The implantation of the artificial iris is a new and effective therapeutic option for the treatment of distinctive traumatic iris defects and results in an individual, aesthetically appealing, and good functional outcome in addition to high patient satisfaction. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Real-time image restoration for iris recognition systems.
Kang, Byung Jun; Park, Kang Ryoung
2007-12-01
In the field of biometrics, it has been reported that iris recognition techniques have shown high levels of accuracy because unique patterns of the human iris, which has very many degrees of freedom, are used. However, because conventional iris cameras have small depth-of-field (DOF) areas, input iris images can easily be blurred, which can lead to lower recognition performance, since iris patterns are transformed by the blurring caused by optical defocusing. To overcome these problems, an autofocusing camera can be used. However, this inevitably increases the cost, size, and complexity of the system. Therefore, we propose a new real-time iris image-restoration method, which can increase the camera's DOF without requiring any additional hardware. This paper presents five novelties as compared to previous works: 1) by excluding eyelash and eyelid regions, it is possible to obtain more accurate focus scores from input iris images; 2) the parameter of the point spread function (PSF) can be estimated in terms of camera optics and measured focus scores; therefore, parameter estimation is more accurate than it has been in previous research; 3) because the PSF parameter can be obtained by using a predetermined equation, iris image restoration can be done in real-time; 4) by using a constrained least square (CLS) restoration filter that considers noise, performance can be greatly enhanced; and 5) restoration accuracy can also be enhanced by estimating the weight value of the noise-regularization term of the CLS filter according to the amount of image blurring. Experimental results showed that iris recognition errors when using the proposed restoration method were greatly reduced as compared to those results achieved without restoration or those achieved using previous iris-restoration methods.
The infrared imaging spectrograph (IRIS) for TMT: latest science cases and simulations
NASA Astrophysics Data System (ADS)
Wright, Shelley A.; Walth, Gregory; Do, Tuan; Marshall, Daniel; Larkin, James E.; Moore, Anna M.; Adamkovics, Mate; Andersen, David; Armus, Lee; Barth, Aaron; Cote, Patrick; Cooke, Jeff; Chisholm, Eric M.; Davidge, Timothy; Dunn, Jennifer S.; Dumas, Christophe; Ellerbroek, Brent L.; Ghez, Andrea M.; Hao, Lei; Hayano, Yutaka; Liu, Michael; Lopez-Rodriguez, Enrique; Lu, Jessica R.; Mao, Shude; Marois, Christian; Pandey, Shashi B.; Phillips, Andrew C.; Schoeck, Matthias; Subramaniam, Annapurni; Subramanian, Smitha; Suzuki, Ryuji; Tan, Jonathan C.; Terai, Tsuyoshi; Treu, Tommaso; Simard, Luc; Weiss, Jason L.; Wincentsen, James; Wong, Michael; Zhang, Kai
2016-07-01
The Thirty Meter Telescope (TMT) first light instrument IRIS (Infrared Imaging Spectrograph) will complete its preliminary design phase in 2016. The IRIS instrument design includes a near-infrared (0.85 - 2.4 micron) integral field spectrograph (IFS) and imager that are able to conduct simultaneous diffraction-limited observations behind the advanced adaptive optics system NFIRAOS. The IRIS science cases have continued to be developed and new science studies have been investigated to aid in technical performance and design requirements. In this development phase, the IRIS science team has paid particular attention to the selection of filters, gratings, sensitivities of the entire system, and science cases that will benefit from the parallel mode of the IFS and imaging camera. We present new science cases for IRIS using the latest end-to-end data simulator on the following topics: Solar System bodies, the Galactic center, active galactic nuclei (AGN), and distant gravitationally-lensed galaxies. We then briefly discuss the necessity of an advanced data management system and data reduction pipeline.
NASA Astrophysics Data System (ADS)
Li, Yung-Hui; Zheng, Bo-Ren; Ji, Dai-Yan; Tien, Chung-Hao; Liu, Po-Tsun
2014-09-01
Cross sensor iris matching may seriously degrade the recognition performance because of the sensor mis-match problem of iris images between the enrollment and test stage. In this paper, we propose two novel patch-based heterogeneous dictionary learning method to attack this problem. The first method applies the latest sparse representation theory while the second method tries to learn the correspondence relationship through PCA in heterogeneous patch space. Both methods learn the basic atoms in iris textures across different image sensors and build connections between them. After such connections are built, at test stage, it is possible to hallucinate (synthesize) iris images across different sensors. By matching training images with hallucinated images, the recognition rate can be successfully enhanced. The experimental results showed the satisfied results both visually and in terms of recognition rate. Experimenting with an iris database consisting of 3015 images, we show that the EER is decreased 39.4% relatively by the proposed method.
Performance Comparison of HPF and MPI Based NAS Parallel Benchmarks
NASA Technical Reports Server (NTRS)
Saini, Subhash
1997-01-01
Compilers supporting High Performance Form (HPF) features first appeared in late 1994 and early 1995 from Applied Parallel Research (APR), Digital Equipment Corporation, and The Portland Group (PGI). IBM introduced an HPF compiler for the IBM RS/6000 SP2 in April of 1996. Over the past two years, these implementations have shown steady improvement in terms of both features and performance. The performance of various hardware/ programming model (HPF and MPI) combinations will be compared, based on latest NAS Parallel Benchmark results, thus providing a cross-machine and cross-model comparison. Specifically, HPF based NPB results will be compared with MPI based NPB results to provide perspective on performance currently obtainable using HPF versus MPI or versus hand-tuned implementations such as those supplied by the hardware vendors. In addition, we would also present NPB, (Version 1.0) performance results for the following systems: DEC Alpha Server 8400 5/440, Fujitsu CAPP Series (VX, VPP300, and VPP700), HP/Convex Exemplar SPP2000, IBM RS/6000 SP P2SC node (120 MHz), NEC SX-4/32, SGI/CRAY T3E, and SGI Origin2000. We would also present sustained performance per dollar for Class B LU, SP and BT benchmarks.
Visualization in aerospace research with a large wall display system
NASA Astrophysics Data System (ADS)
Matsuo, Yuichi
2002-05-01
National Aerospace Laboratory of Japan has built a large- scale visualization system with a large wall-type display. The system has been operational since April 2001 and comprises a 4.6x1.5-meter (15x5-foot) rear projection screen with 3 BARCO 812 high-resolution CRT projectors. The reason we adopted the 3-gun CRT projectors is support for stereoscopic viewing, ease with color/luminosity matching and accuracy of edge-blending. The system is driven by a new SGI Onyx 3400 server of distributed shared-memory architecture with 32 CPUs, 64Gbytes memory, 1.5TBytes FC RAID disk and 6 IR3 graphics pipelines. Software is another important issue for us to make full use of the system. We have introduced some applications available in a multi- projector environment such as AVS/MPE, EnSight Gold and COVISE, and been developing some software tools that create volumetric images with using SGI graphics libraries. The system is mainly used for visualization fo computational fluid dynamics (CFD) simulation sin aerospace research. Visualized CFD results are of our help for designing an improved configuration of aerospace vehicles and analyzing their aerodynamic performances. These days we also use it for various collaborations among researchers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-11-01
The report includes information and material from a technical review workshop organized by the U.S. Environmental Protection Agency`s (EPA`s) Risk Assessment Forum for EPA`s Reference Dose/Reference Concentration (RfD/RfC) Work Group. The meeting was held in Washington, DC, at the Barcelo Washington Hotel on May 24-25, 1994. The subject of the technical review was the Integrated Risk Information System (IRIS) RfD entry for Aroclor 1016, a polychlorinated biphenyl (PCB). The expert technical review panel was convened to independently evaluate whether the RfD for Aroclor 1016 is based on a scientifically responsible analysis that represents full consideration of the available data andmore » clean articulation of that analysis in the IRIS RfD entry. EPA also requested panel members to consider four broad options for the Aroclor 1016 RfD as potential recommendations to the RfD/RfC Work Group.« less
Integrated Risk Information System (IRIS)
Fluorine ( soluble fluoride ) ; CASRN 7782 - 41 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for No
Integrated Risk Information System (IRIS)
EPA / 635 / R - 03 / 005 www.epa.gov / iris TOXICOLOGICAL REVIEW OF HYDROGEN SULFIDE ( CAS No . 7783 - 06 - 4 ) In Support of Summary Information on the Integrated Risk Information System ( IRIS ) June 2003 U.S . Environmental Protection Agency Washington , DC DISCLAIMER This document has been
Integrated Risk Information System (IRIS)
Vinyl acetate ; CASRN 108 - 05 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff
Integrated Risk Information System (IRIS)
Methyl iodide ; CASRN 74 - 88 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Effe
Integrated Risk Information System (IRIS)
1,2 - Dibromoethane ; CASRN 106 - 93 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogen
Integrated Risk Information System (IRIS)
2 - Chlorobutane ; CASRN 78 - 86 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic E
Plateau Iris - Therapeutic options and functional results after treatment.
Feraru, Crenguța; Bâlha, Andrei; Aursulesei, Victor; Filip, Andrei; Pantalon, Anca
2017-01-01
We present the therapeutic options and functional results in patients with plateau iris (syndrome or configuration) in consecutive case series. Material and method: Our study included newly diagnosed patients with acute angle closure by "plateau iris" (configuration or syndrome), between June 2016 and April 2017. Series of 8 consecutive patients met the inclusion criteria, all being females. All the patients underwent an individualized treatment according to the underlying mechanism and evolution. Functional results (visual acuity, IOP, topical medication) were reported in the current paper. Results: For 10 months, we diagnosed 14 eyes, from 9 patients with acute angle closure by Plateau Iris, distributed as it follows: 6 eyes with closed angle glaucoma (optic disk and visual field changes), 8 eyes with plateau iris syndrome and 2 eyes with plateau iris configuration. 7/ 8 patients were misdiagnosed with primary open angle glaucoma, whereas only one patient had the correct diagnosis of closed angle glaucoma and underwent peripheral laser iridotomy. As treatment options in our study, we recommended and performed argon laser peripheral iridoplasty + iridotomy in 10/ 14 eyes, cataract lens was extracted in 4 eyes and then replaced with PC-IOL, whereas 2 eyes required a filtering anti-glaucoma surgery (trabeculectomy + PI). 2 eyes from the same patient could not be treated as intended as the patient refused the treatment. In this unique case, Pilocarpine (4%) was temporarily indicated. Conclusion: Plateau iris represents a diagnostic trap, but based on a thorough gonioscopic examination and a good patient history, the right diagnosis can be made, all along with a correct therapeutic approach.
Dar, B A; Lone, S H; Shah, W A; Bhat, K A
2016-08-01
The genus Iris is diverse both in the abundance of secondary metabolities as well as the biological activities. The rhizomes of Iris hookeriana exhibit significant anthelminthic activity against gastrointestinal nematodes of sheep. Although Iris hookeriana has been a subject of the study of so many phytochemical studies, yet we report some constituents for the first time from this plant using a different isolation approach. This manuscript presents the isolation, antimicrobial and antioxidant evaluation of bioactive principles from Iris hookeriana. LC-MS guided isolation technique was applied for the separation of target constituents. The isolates were characterised by spectral techniques and subjected to antioxidant evaluation by DPPH assay. Four compounds; resveratrol, resveratroloside, junipeginin C and isorhamnetin-3-O-neohesperidoside were isolated for the first time along with 3 known compounds viz piceid, irigenin and iridin from I. hookeriana using this approach. The antioxidant activity screening of the isolates revealed that all the 4 constituents isolated for the first time, have strong antioxidant potential with IC50 of 14.0 µg/ml (resveratroloside), 19.7 µg/ml (junipeginen C), 12.8 µg/ml (resveratrol) and 19.8 µg/ml (isorhamnetin-3-O-neohesperodoside). So it can be safely concluded that LC-MS guided isolation of chemical compounds from Iris hookeriana has furnished 4 antioxidant constituents. Thus Iris hookeriana can act as as a good source of wonder molecule resveratrol and its 2 glycosides, resveratrolside and piceid which upon hydrolysis can be converted into the parent drug resveratrol. © Georg Thieme Verlag KG Stuttgart · New York.
Lack of Radiation Maculopathy After Palladium-103 Plaque Radiotherapy for Iris Melanoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yousef, Yacoub A.; Finger, Paul T., E-mail: pfinger@eyecancer.com
2012-07-15
Purpose: To report on the risk of radiation maculopathy for iris and iridociliary melanomas treated by {sup 103}Pd plaque radiotherapy. Methods and Materials: This is a retrospective clinical case series of 30 eyes in 30 patients with melanomas limited to the iris or invading the ciliary body. The main outcome measures included demographic information, laterality, tumor size, location, visual acuity, radiation dose, local control, retinal evaluation, and duration of follow-up. Results: Thirty patients were followed for a median 36 months (range, 12-90 months). Sixteen of 30 tumors (53%) were pure iris melanomas, and 14 (47%) were primary iris melanomas extendingmore » into the ciliary body. Radiation dosimetry showed that the median tumor apex dose was 85 Gy (range, 75-100 Gy), lens dose 43.5 Gy (range, 17.8-60 Gy), fovea dose 1.8 Gy (range, 1.3-5 Gy), and central optic disc dose 1.7 Gy (range, 1.3-4.7 Gy). Cataracts developed in 20 of the 28 phakic eyes (71.4%). No patient in this series developed radiation maculopathy or radiation optic neuropathy. Last best-corrected visual acuity was {>=}20/25 in 28 patients (93%) at a median 36 months' follow-up. Conclusion: Though visual acuities were transiently affected by radiation cataract, no radiation maculopathy or optic neuropathy has been noted after {sup 103}Pd treatment of iris and iridociliary melanomas.« less
Martins, Renata Cristófani; Buchalla, Cassia Maria
2015-01-01
To prepare a dictionary in Portuguese for using in Iris and to evaluate its completeness for coding causes of death. Iniatially, a dictionary with all illness and injuries was created based on the International Classification of Diseases - tenth revision (ICD-10) codes. This dictionary was based on two sources: the electronic file of ICD-10 volume 1 and the data from Thesaurus of the International Classification of Primary Care (ICPC-2). Then, a death certificate sample from the Program of Improvement of Mortality Information in São Paulo (PRO-AIM) was coded manually and by Iris version V4.0.34, and the causes of death were compared. Whenever Iris was not able to code the causes of death, adjustments were made in the dictionary. Iris was able to code all causes of death in 94.4% death certificates, but only 50.6% were directly coded, without adjustments. Among death certificates that the software was unable to fully code, 89.2% had a diagnosis of external causes (chapter XX of ICD-10). This group of causes of death showed less agreement when comparing the coding by Iris to the manual one. The software performed well, but it needs adjustments and improvement in its dictionary. In the upcoming versions of the software, its developers are trying to solve the external causes of death problem.
Breast Cancer in Context: New Tools and Paradigms for the Millennium
2007-07-01
arrest. The percentage of TUNEL-positive nuclei increased from 24 to 72 hours. Treatment with AIIB2 results in decreased tumor forma - tion, increased...manipulation on the ability of these cells to execute acinar morphogenesis (Debnath et al., 2002, 2003; Gunawardane et al., 2005; Irie et al., 2005; Isakoff et...breast cancer cell lines. Cancer Research 58, 1972–1977. Irie , H.Y., Pearline, R.V., Grueneberg, D., Hsia, M., Ravichandran, P., Kothari, N., Natesan, S
NASA Astrophysics Data System (ADS)
Sun, Hui; Kurtz, Ronald M.; Juhasz, Tibor
2010-02-01
Multiple femtosecond lasers have now been cleared for use for ophthalmic surgery, including for creation of corneal flaps in LASIK surgery. Preliminary measurements indicated that during typical surgical use, 50-60% of laser energy may pass beyond the cornea with potential effects on the iris. To further evaluate iris laser exposure during femtosecond corneal surgery, we measured the temperature increase in porcine cadaver iris in situ during direct illumination by the iFS Advanced Femtoosecond Laser (AMO Inc. Santa Ana, CA) with an infrared thermal imaging camera. To replicate the illumination geometry of the eye during the surgery, an excised porcine cadaver iris was placed 1.5 mm from the flat glass contact lens. The temperature field was observed in twenty cadaver iris at laser pulse energy levels ranging from 1 to 2 μJ (corresponding approximately to surgical energies of 2 to 4 μJ per pulse). Temperature increases up to 2.3 °C (corresponding to 2 μJ per pulse and 24 second procedure time) were observed in the cadaver iris with little variation in temperature profiles between specimens for the same laser energy illumination. For laser pulse energy and procedure time characteristic to the iFS Advanced Femtoosecond Laser the temperature increase was measured to be 1.2 °C. Our studies suggest that the magnitude of iris heating that occurs during such femtosecond laser corneal surgery is small and does not present a safety hazard to the iris.
Cao, Qi; Wang, Yiping; Niu, Zhiguo; Wang, Chengshi; Wang, Ruifeng; Zhang, Zhiqiang; Chen, Titi; Wang, Xin Maggie; Li, Qing; Lee, Vincent W S; Huang, Qingsong; Tan, Jing; Guo, Minghao; Wang, Yuan Min; Zheng, Guoping; Yu, Di; Alexander, Stephen I; Wang, Hui; Harris, David C H
2018-03-01
The IL-33-type 2 innate lymphoid cell (ILC2) axis has an important role in tissue homeostasis, inflammation, and wound healing. However, the relative importance of this innate immune pathway for immunotherapy against inflammation and tissue damage remains unclear. Here, we show that treatment with recombinant mouse IL-33 prevented renal structural and functional injury and reduced mortality in mice subjected to ischemia-reperfusion injury (IRI). Compared with control-treated IRI mice, IL-33-treated IRI mice had increased levels of IL-4 and IL-13 in serum and kidney and more ILC2, regulatory T cells (Tregs), and anti-inflammatory (M2) macrophages. Depletion of ILC2, but not Tregs, substantially abolished the protective effect of IL-33 on renal IRI. Adoptive transfer of ex vivo -expanded ILC2 prevented renal injury in mice subjected to IRI. This protective effect associated with induction of M2 macrophages in kidney and required ILC2 production of amphiregulin. Treatment of mice with IL-33 or ILC2 after IRI was also renoprotective. Furthermore, in a humanized mouse model of renal IRI, treatment with human IL-33 or transfer of ex vivo -expanded human ILC2 ameliorated renal IRI. This study has uncovered a major protective role of the IL-33-ILC2 axis in renal IRI that could be potentiated as a therapeutic strategy. Copyright © 2018 by the American Society of Nephrology.
Hahn, Roberta Z; Arnhold, Priscila C; Andriguetti, Natália B; Schneider, Anelise; Klück, Helena M; Dos Reis, Simone L; Bastiani, Marcos Frank; Kael, Igor; da Silva, Anne Caroline Cezimbra; Schwartsmann, Gilberto; Antunes, Marina V; Linden, Rafael
2018-02-20
Irinotecan (IRI) is an antineoplastic drug widely used for the treatment of colorectal and advanced pancreatic cancer. Despite its clinical utility, the clinical use of IRI is associated with potentially severe hematopoietic and gastrointestinal toxicities. The quantification of IRI and its active metabolite SN-38 in dried blood spots (DBS) may be an alternative to individualize the drug dose through a minimally invasive and easy collection method. The aim of this study was to develop and validate a simple and fast HPLC-FL assay for simultaneous IRI and SN-38 measurement in DBS, with adequate analytical performance for clinical use. The method employs liquid extraction of one 8mm disk of whole blood, followed by separation in a reversed phase Eclipse Plus C8 column (150×4.6mm, 5μm). Detection was performed with a fluorescence detector, with excitation wavelength of 370 and emission of 420 for IRI and 540nm for SN-38 and internal standard (camptothecin). Total analytical run time was 17min. Mobile phase was a mixture of 0.1M phosphate buffer pH 4.0 and acetonitrile (80:20, v/v), at 1mLmin -1 . The assay was linear in the range 10-3,000ngmL -1 and from 0.5 to 300ngmL -1 for IRI and SN-38, respectively. Precision assays presented CV% of 2.71-5.65 and 2.15-10.07 for IRI and SN-38, respectively, and accuracy in the range of 94.26-100.93 and 94.24-99.33%. IRI and SN-38 were stable at 25 and 42°C for 14days in DBS samples. The method was applied to DBS samples obtained from fingerpicks from 19 volunteers receiving IRI in single or combined chemotherapy regimens, collected 1 and 24h after beginning of the infusion. The estimated plasma concentration of IRI and SN-38 in sample collected 1h after star of infusion had 16 of 19 values within the ±20% range of the measured plasma concentrations. On the other hand, predictions of IRI and SN-38 plasma concentrations from DBS measurements obtained 24h after the beginning of the infusion were poor. AUC of IRI that was calculated using plasma and DBS-estimated concentrations, with a high correlation (r=0.918). The method presented suitable characteristics for the clinical use. However, translation of IRI and SN-38 DBS to plasma concentrations is challenging due to the compound's variable plasma/blood partition. Copyright © 2017 Elsevier B.V. All rights reserved.
Iguchi, Mitsuko; Kakinuma, Yoshihiko; Kurabayashi, Atsushi; Sato, Takayuki; Shuin, Taro; Hong, Seung-Beom; Schmidt, Laura S.; Furihata, Mutsuo
2009-01-01
Background/Aims The von Hippel-Lindau (pVHL) protein functions as an E3 ubiquitin ligase, controlling the stability of hypoxia inducible factor (HIF). Pre-induction of HIF-1α before pathological insult activates a self-defense mechanism and suppresses further aggravation of organ or cellular injury by ischemia. We investigated whether acute inactivation of the VHL gene might play a role in the response of mice to ischemic renal injury. Methods We generated tamoxifen-inducible conditional VHL knockout (VHL-KO) mice to inactivate the VHL gene in an acute manner during renal ischemia-reperfusion injury (IRI) induced by bilateral clamping of kidney arteries. Renal IRI is characterized by renal dysfunction and tubular damage. Results After the procedure of IRI, blood urea nitrogen (BUN) and creatinine (CRN) levels in control mice were significantly higher (BUN, 138.10±13.03 mg/dL; CRN, 0.72±0.16 mg/dL) than in VHL-KO mice (BUN, 52.12±6.61 mg/dL; CRN, 0.24±0.04 mg/dL; BUN: p<0.05; CRN: p<0.05). Histologically, tubular injury scores were higher in control mice than in VHL-KO mice (p<0.05). Conclusion We suggest that the acute inactivation of the VHL gene contributes to protective effects of ischemic preconditioning in renal tubules of the mouse. PMID:18957870
NASA Astrophysics Data System (ADS)
Zhou, J.; Deyhim, A.; Krueger, S.; Gregurick, S. K.
2005-08-01
A program for determining the low resolution shape of biological macromolecules, based on the optimization of a small angle neutron scattering profile to experimental data, is presented. This program, termed LORES, relies on a Monte Carlo optimization procedure and will allow for multiple scattering length densities of complex structures. It is therefore more versatile than utilizing a form factor approach to produce low resolution structural models. LORES is easy to compile and use, and allows for structural modeling of biological samples in real time. To illustrate the effectiveness and versatility of the program, we present four specific biological examples, Apoferritin (shell model), Ribonuclease S (ellipsoidal model), a 10-mer dsDNA (duplex helix) and a construct of a 10-mer DNA/PNA duplex helix (heterogeneous structure). These examples are taken from protein and nucleic acid SANS studies, of both large and small scale structures. We find, in general, that our program will accurately reproduce the geometric shape of a given macromolecule, when compared with the known crystallographic structures. We also present results to illustrate the lower limit of the experimental resolution which the LORES program is capable of modeling. Program summaryTitle of program:LORES Catalogue identifier: ADVC Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADVC Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Computer:SGI Origin200, SGI Octane, SGI Linux, Intel Pentium PC Operating systems:UNIX64 6.5 and LINUX 2.4.7 Programming language used:C Memory required to execute with typical data:8 MB No. of lines in distributed program, including test data, etc.:2270 No. of bytes in distributed program, including test data, etc.:13 302 Distribution format:tar.gz External subprograms used:The entire code must be linked with the MATH library
Impact on TRMM Products of Conversion to Linux
NASA Technical Reports Server (NTRS)
Stocker, Erich Franz; Kwiatkowski, John
2008-01-01
In June 2008, TRMM data processing will be assumed by the Precipitation Processing System (PPS). This change will also mean a change in the hardware production environment from an SGI 32 bit IRIX processing environment to a Linux (Beowulf) 64 bit processing environment. This change of platform and operating system addressing (32 to 64) has some influence on data values in the TRMM data products. This paper will describe the transition architecture and scheduling. It will also provide an analysis of what the nature of the product differences will be. It will demonstrate that the differences are not scientifically significant and are generally not visible. However, they are not always identical with those which the SGI would produce.
Integrated Risk Information System (IRIS)
Bis ( chloroethyl ) ether ( BCEE ) ; CASRN 111 - 44 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments fo
Integrated Risk Information System (IRIS)
1,3,5 - Trinitrobenzene ; CASRN 99 - 35 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcino
Dual effect of silymarin on experimental non-alcoholic steatohepatitis induced by irinotecan.
Marcolino Assis-Júnior, Eudmar; Melo, Anielle Torres; Pereira, Venúcia Bruna Magalhães; Wong, Deysi Viviana Tenazoa; Sousa, Nathalia Ribeiro Pinho; Oliveira, Christiane Mendes Gonçalves; Malveira, Lara Raissa Cavalcante; Moreira, Leonardo Silva; Souza, Marcellus Henrique Loiola Ponte; Almeida, Paulo Roberto Carvalho; Lima-Júnior, Roberto César Pereira
2017-07-15
Irinotecan-based regimens are commonly used for treatment of colorectal cancer, which is limited by mucositis and non-alcoholic steatohepatitis (NASH). Silymarin (SIL) prevents fatty liver disease in the clinical setting and in models of liver damage induced chemically. This study investigated the possible effect of SIL on irinotecan (IRI)-induced NASH. Swiss female mice were injected with saline (SAL 5ml/kg i.p.), IRI (50mg/kg i.p.), SIL (150mg/kg p.o.) or IRI (50mg/kg i.p.)+(SIL 1.5, 15 or 150mg/kg p.o.) thrice/week/7weeks. On the seventh week, blood samples were collected for transaminases assay and livers were collected for histopathology, measurement of the total lipids, malondyadehyde (MDA), non-protein sulfhydryl groups (NPSH), cytokines (IL-1β, IL 6 and IL-10), 3-nitrotyrosine (N-Tyr) and toll-like receptor 4 (TLR4) immunoexpression, quantification of NF-kB, α-smooth muscle actin (α-SMA), and Escherichia coli 16S rRNA gene (RRS) expression. IRI increased liver transaminases, neutrophil infiltration, lipid accumulation, MDA, IL-1β and IL-6 levels, N-Tyr and TLR4 immunostaining, NF-kB, α-SMA expression and RRS versus the SAL group (p<0.05). Additionally, SIL (1.5mg/kg) improved these parameters (p<0.05), except neutrophil infiltration and RSS versus the IRI group. Furthermore, the SIL (15mg/kg) only improved the inflammatory parameters, the expression of α-SMA and RRS versus the IRI group (p<0.05). The higher dose of SIL (150mg/kg) was even more deleterious than the intermediate dose. Therefore, silymarin showed a dual effect on liver damage induced by IRI. Hepatoprotection seems to involve the inhibition of oxidative stress and protein nitrosylation, preventing activation of hepatic fibrosis mechanisms. Copyright © 2017 Elsevier Inc. All rights reserved.
Spitzer, Martin Stephan; Nessmann, Anja; Wagner, Julia; Yoeruek, Efdal; Bartz-Schmidt, Karl Ulrich; Szurman, Peter; Szurman, Gesine B
2016-05-01
Posttraumatic partial or total iris defects often cause significant debilitating glare, photophobia, decreased vision and cosmetic problems. Currently, the best cosmetic results can be obtained with a customized silicone iris prosthesis. However, little is known about the functional results and the rate of complication if this type of iris prosthesis is implanted into severely traumatized eyes. The aim of this study is to analyse the functional and cosmetic outcomes as well as complications after Artificial Iris implantation. A consecutive series of 34 patients who received a customized silicone iris prosthesis after severe globe injury with total or sub-total iris loss was analysed retrospectively. Additionally, patients were interviewed regarding change in subjective complaints. Median follow-up was 24 months (range 12.0-48.8). Mean visual acuity prior to Artificial Iris implantation was 1.1 logMAR (range 0.3-2.6). Five patients (15%) had pre-existing glaucoma and eight patients (24%) had pre-existing hypotony. Visual acuity 12 months after surgery was 1.4 logMAR (range 0.2-2.6). Complications included newly diagnosed glaucoma in three eyes (9%) and hypotony in three eyes (9%), persisting intraocular inflammation or macular oedema in seven patients (21%), and corneal endothelial decompensation requiring corneal transplantation in six patients (18%). Patients' satisfaction increased by reducing glare and enhanced cosmetic appearance. The customized silicone iris prosthesis is an individualized treatment approach with appealing cosmetic results. Therefore, especially traumatized eyes with highly different posttraumatic conditions could benefit. However, in some patients, the implantation of this device may cause an increase of intraocular pressure, corneal endothelial decompensation or persisting inflammation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A
2017-08-01
Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.
Roberts, Philipp K.; Goldstein, Debra A.; Fawzi, Amani A.
2017-01-01
Purpose/Aim of the study To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Materials and Methods Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Results Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the “eyes at risk” group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. Conclusions This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI. PMID:28441067
DOE Office of Scientific and Technical Information (OSTI.GOV)
Satake, Shin-ichi; Kanamori, Hiroyuki; Kunugi, Tomoaki
2007-02-01
We have developed a parallel algorithm for microdigital-holographic particle-tracking velocimetry. The algorithm is used in (1) numerical reconstruction of a particle image computer using a digital hologram, and (2) searching for particles. The numerical reconstruction from the digital hologram makes use of the Fresnel diffraction equation and the FFT (fast Fourier transform),whereas the particle search algorithm looks for local maximum graduation in a reconstruction field represented by a 3D matrix. To achieve high performance computing for both calculations (reconstruction and particle search), two memory partitions are allocated to the 3D matrix. In this matrix, the reconstruction part consists of horizontallymore » placed 2D memory partitions on the x-y plane for the FFT, whereas, the particle search part consists of vertically placed 2D memory partitions set along the z axes.Consequently, the scalability can be obtained for the proportion of processor elements,where the benchmarks are carried out for parallel computation by a SGI Altix machine.« less
US Army Armor Reference Data in Three Volumes. Volume II. Nondivisional Organizations.
1981-01-01
SQuat 1r) R 2 SGI IB20 (Team Ldr) R I SP4 19GIO (Loader/Gnr) P I SP5 19G20 (St Gunner) P 1 t,5 19G20 (Sr Gunner) P I SP4 IICII ()Carrrr Dv) P 2 SP4 11810...Sergeant 2 SP4 Mat Storage Sp 1 SIC Platoon SOT1 SPC Food Svc SGT 1 SP4 Supply Con & Acct Cik 1 SP4 Lt Veh DriverI SFC Motor Sergeant I SP4 Subsistence...PLATOON Ho-.-- Loader Scoop Type 2-1/2 CU YD .Platoon Leader Tank Fabric Fuel 10,000-Gal. 1 SPC Platoon SC? 1 PFlC Reports Clerk 0lRadio Set N/VRC-46
NASA Astrophysics Data System (ADS)
Erickson, Ricky A.; Moren, Stephen E.; Skalka, Marion S.
1998-07-01
Providing a flexible and reliable source of IR target imagery is absolutely essential for operation of an IR Scene Projector in a hardware-in-the-loop simulation environment. The Kinetic Kill Vehicle Hardware-in-the-Loop Simulator (KHILS) at Eglin AFB provides the capability, and requisite interfaces, to supply target IR imagery to its Wideband IR Scene Projector (WISP) from three separate sources at frame rates ranging from 30 - 120 Hz. Video can be input from a VCR source at the conventional 30 Hz frame rate. Pre-canned digital imagery and test patterns can be downloaded into stored memory from the host processor and played back as individual still frames or movie sequences up to a 120 Hz frame rate. Dynamic real-time imagery to the KHILS WISP projector system, at a 120 Hz frame rate, can be provided from a Silicon Graphics Onyx computer system normally used for generation of digital IR imagery through a custom CSA-built interface which is available for either the SGI/DVP or SGI/DD02 interface port. The primary focus of this paper is to describe our technical approach and experience in the development of this unique SGI computer and WISP projector interface.
Accelerated Modeling and New Ferroelectric Materials for Naval SONAR
2004-06-01
AN other platforms was achieved. As expected, proper into BZ leads to a development of small polarization, vectorization and optimal memory usage were...polarization is due to a combination code was fully vectorized , a speed-up of 9.2 times over of large Ag off-centering and small displacements by the Pentium 4... Xeon and 6.6 times over the SGI 03K was other cations. The large Ag displacements are due to a achieved. We are currently using the X1 in production
Methyl tert-butyl ether (MTBE)
Integrated Risk Information System (IRIS)
Methyl tert - butyl ether ( MTBE ) ; CASRN 1634 - 04 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments f
Implementation Of Simulink Controller Design On IRIS+ Quadrotor
2015-09-01
product: 3DR radio. (n.d.). 3D Robotics. [Online]. Available: https://store.3drobotics.com/products/3dr-radio-set. Accessed July. 19, 2015. [33] DIY ...drones forum. (n.d.). DIY drones. [Online]. Available: http://diydrones.com/forum/topics/3dr-radios-will-not-connect-for-initial- setup. Accessed Aug
Dai, Erpeng; Zhang, Zhe; Ma, Xiaodong; Dong, Zijing; Li, Xuesong; Xiong, Yuhui; Yuan, Chun; Guo, Hua
2018-03-23
To study the effects of 2D navigator distortion and noise level on interleaved EPI (iEPI) DWI reconstruction, using either the image- or k-space-based method. The 2D navigator acquisition was adjusted by reducing its echo spacing in the readout direction and undersampling in the phase encoding direction. A POCS-based reconstruction using image-space sampling function (IRIS) algorithm (POCSIRIS) was developed to reduce the impact of navigator distortion. POCSIRIS was then compared with the original IRIS algorithm and a SPIRiT-based k-space algorithm, under different navigator distortion and noise levels. Reducing the navigator distortion can improve the reconstruction of iEPI DWI. The proposed POCSIRIS and SPIRiT-based algorithms are more tolerable to different navigator distortion levels, compared to the original IRIS algorithm. SPIRiT may be hindered by low SNR of the navigator. Multi-shot iEPI DWI reconstruction can be improved by reducing the 2D navigator distortion. Different reconstruction methods show variable sensitivity to navigator distortion or noise levels. Furthermore, the findings can be valuable in applications such as simultaneous multi-slice accelerated iEPI DWI and multi-slab diffusion imaging. © 2018 International Society for Magnetic Resonance in Medicine.
Global 3-D ionospheric electron density reanalysis based on multisource data assimilation
NASA Astrophysics Data System (ADS)
Yue, Xinan; Schreiner, William S.; Kuo, Ying-Hwa; Hunt, Douglas C.; Wang, Wenbin; Solomon, Stanley C.; Burns, Alan G.; Bilitza, Dieter; Liu, Jann-Yenq; Wan, Weixing; Wickert, Jens
2012-09-01
We report preliminary results of a global 3-D ionospheric electron density reanalysis demonstration study during 2002-2011 based on multisource data assimilation. The monthly global ionospheric electron density reanalysis has been done by assimilating the quiet days ionospheric data into a data assimilation model constructed using the International Reference Ionosphere (IRI) 2007 model and a Kalman filter technique. These data include global navigation satellite system (GNSS) observations of ionospheric total electron content (TEC) from ground-based stations, ionospheric radio occultations by CHAMP, GRACE, COSMIC, SAC-C, Metop-A, and the TerraSAR-X satellites, and Jason-1 and 2 altimeter TEC measurements. The output of the reanalysis are 3-D gridded ionospheric electron densities with temporal and spatial resolutions of 1 h in universal time, 5° in latitude, 10° in longitude, and ˜30 km in altitude. The climatological features of the reanalysis results, such as solar activity dependence, seasonal variations, and the global morphology of the ionosphere, agree well with those in the empirical models and observations. The global electron content derived from the international GNSS service global ionospheric maps, the observed electron density profiles from the Poker Flat Incoherent Scatter Radar during 2007-2010, and foF2 observed by the global ionosonde network during 2002-2011 are used to validate the reanalysis method. All comparisons show that the reanalysis have smaller deviations and biases than the IRI-2007 predictions. Especially after April 2006 when the six COSMIC satellites were launched, the reanalysis shows significant improvement over the IRI predictions. The obvious overestimation of the low-latitude ionospheric F region densities by the IRI model during the 23/24 solar minimum is corrected well by the reanalysis. The potential application and improvements of the reanalysis are also discussed.
The effects of tamsulosin and alfuzosin on iris morphology: an ultrasound biomicroscopic comparison.
Aktas, Zeynep; Yuksel, Nilay; Ceylan, Gurhan; Polat, Fazli; Hasanreisoglu, Murat; Hasanreisoglu, Berati
2015-03-01
It is well known that Alpha-1 adrenergic receptor antagonists affect the receptors in the prostate and also iris dilator muscle, leading to loss of iris muscle tone. To compare morphological alterations of iris secondary to tamsulosin and alfuzosin use. Patients included in the study were grouped as follows: 16 patients treated with tamsulosin (Group 1), 14 patients treated with alfuzosin (Group 2) and 18 untreated controls (Group 3). All patients underwent ultrasound biomicroscopic and pupillometric examination. Iris thickness was measured at the dilator muscle region (DMR; measured at half of the distance between the scleral spur and the pupillary margin) and sphincter muscle region (SMR; Standardized at 0.75 mm from the pupillary margin). DMR/SMR was also calculated for each patient. Differences among groups were analysed. Main outcome measures were DMR, SMR, DMR/SMR and pupillary diameter. Mean duration of treatments were 2.4 ± 0.96 years (1-4) and 2.3 ± 1.01 years (1-4) in Groups 1 and 2. Pupillary diameters were reduced in Groups 1-2 compared to Group 3 (p < 0.001, p < 0.001). The SMR was similar in Groups 1 and 2 (p: 0.114). These values were not significantly different from that of Group 3 (p: 0.196, p: 0.209). However, thickness in the DMR in Groups 1-2 were significantly lower than that of controls (Group 3) whereas there was no significant difference between Groups 1 and 2 (p: 0.041, p: 0.039 and 0.986, respectively). Mean DMR/SMR ratios were significantly lower in Groups 1-2 than that of Group 3 (p: 0.040 and p: 0.040, respectively). In patients using these medications, the iris seems to be thinner at the dilator muscle region, but preserving the sphincter muscle region.
Mechanism of action of nicotine in isolated iris sphincter preparations of rabbit.
Hisayama, T.; Shinkai, M.; Takayanagi, I.; Morimoto, S.; Ishida, K.
1988-01-01
1. Nicotine produced a transient contraction of rabbit isolated iris sphincter muscle, a parasympathetic ganglion-free tissue. The response to nicotine was antagonized by hexamethonium, but was insensitive to tetrodotoxin (TTX). While single treatments with atropine, capsaicin or [D-Arg1, D-Pro2, D-Trp7,9, Leu11]-substance P (rpwwL-SP) partially blocked the response, combined treatment abolished it. 2. Chronic treatment of animals with nicotine added to the drinking water (about 12 mg kg-1 per day) had no effect on the responsiveness to nicotine or the pharmacological properties of nicotine-induced contraction. 3. These results suggest that acetylcholine and tachykinin(s) released via sodium channel-independent mechanisms from nerve terminals of parasympathetic and primary sensory nerves, respectively, are involved in the nicotine-induced contractile response. PMID:3228672
High-frequency ultrasound measurements of the normal ciliary body and iris.
Garcia, Julian P S; Spielberg, Leigh; Finger, Paul T
2011-01-01
To determine the normal ultrasonographic thickness of the iris and ciliary body. This prospective 35-MHz ultrasonographic study included 80 normal eyes of 40 healthy volunteers. The images were obtained at the 12-, 3-, 6-, and 9-o'clock radial meridians, measured at three locations along the radial length of the iris and at the thickest section of the ciliary body. Mixed model was used to estimate eye site-adjusted means and standard errors and to test the statistical difference of adjusted results. Parameters included mean thickness, standard deviation, and range. Mean thicknesses at the iris root, midway along the radial length of the iris, and at the juxtapupillary margin were 0.4 ± 0.1, 0.5 ± 0.1, and 0.6 ± 0.1 mm, respectively. Those of the ciliary body, ciliary processes, and ciliary body + ciliary processes were 0.7 ± 0.1, 0.6 ± 0.1, and 1.3 ± 0.2 mm, respectively. This study provides standard, normative thickness data for the iris and ciliary body in healthy adults using ultrasonographic imaging. Copyright 2011, SLACK Incorporated.
Effects of prostaglandins and thromboxane analogues on bullock and dog iris sphincter preparations.
Dong, Y. J.; Jones, R. L.
1982-01-01
1 The bullock iris sphincter was contracted by low concentrations of prostaglandin E2 (PGE2), 16, 16-dimethyl PGE2 and 17,18,19,20-tetranor-16-p-chlorophenoxy PGE2. Other compounds with thromboxane-like actions, for example 11,9-epoxymethano PGH2, were also potent spasmogens, ZK 36374, a stable carbacyclin, was a partial agonist on the PGE-sensitive system of this tissue. 2 The thromboxane antagonist, EP 045, had little effect on the action of PGE2 and 16,16-dimethyl PGE2 on the bullock iris. 3 The dog iris sphincter was sensitive to PGF2 alpha but not to PGE2 and 11,9-epoxymethano PGH2. 4 16,16-dimethyl PGE2 had very low activity on the dog iris in contrast to its high activity on the bullock iris. The reverse was found with the 17,18,19,20-tetranor-16-m-trifluoromethylphenoxy analogue of PGF2 alpha (ICI 81008). This indicates a considerable selectivity of action of the two analogues. 5 The results are discussed in relation to the existing knowledge of prostanoid receptors. PMID:6177369
NASA Technical Reports Server (NTRS)
Green, Robert O.; Hook, Simon J.; Middleton, Elizabeth; Turner, Woody; Ungar, Stephen; Knox, Robert
2012-01-01
The NASA HyspIRI mission is planned to provide global solar reflected energy spectroscopic measurement of the terrestrial and shallow water regions of the Earth every 19 days will all measurements downlinked. In addition, HyspIRI will provide multi-spectral thermal measurements with a single band in the 4 micron region and seven bands in the 8 to 12 micron region with 5 day day/night coverage. A direct broadcast capability for measurement subsets is also planned. This HyspIRI mission is one of those designated in the 2007 National Research Council (NRC) Decadal Survey: Earth Science and Applications from Space. In the Decadal Survey, HyspIRI was recognized as relevant to a range of Earth science and science applications, including climate: "A hyperspectral sensor (e.g., FLORA) combined with a multispectral thermal sensor (e.g., SAVII) in low Earth orbit (LEO) is part of an integrated mission concept [described in Parts I and II] that is relevant to several panels, especially the climate variability panel." The HyspIRI science study group was formed in 2008 to evaluate and refine the mission concept. This group has developed a series of HyspIRI science objectives: (1) Climate: Ecosystem biochemistry, condition & feedback; spectral albedo; carbon/dust on snow/ice; biomass burning; evapotranspiration (2) Ecosystems: Global plant functional types, physiological condition, and biochemistry including agricultural lands (3) Fires: Fuel status, fire frequency, severity, emissions, and patterns of recovery globally (4) Coral reef and coastal habitats: Global composition and status (5) Volcanoes: Eruptions, emissions, regional and global impact (6) Geology and resources: Global distributions of surface mineral resources and improved understanding of geology and related hazards These objectives are achieved with the following measurement capabilities. The HyspIRI imaging spectrometer provides: full spectral coverage from 380 to 2500 at 10 nm sampling; 60 m spatial sampling with a 150 km swath; and fully downlinked coverage of the Earth's terrestrial and shallow water regions every 19 days to provide seasonal cloud-free coverage of the terrestrial surface. The HyspIRI Multi-Spectral Thermal instrument provides: 8 spectral bands from 4 to 12 microns; 60 m spatial sampling with a 600 km swath; and fully downlinked coverage of the Earth's terrestrial shallow water regions every 5 days (day/night) to provide nominally cloud-free monthly coverage. The HyspIRI mission also includes an on-board processing and direct broadcast capability, referred to as the Intelligent Payload Module (IPM), which will allow users with the appropriate antenna to download a subset of the HyspIRI data stream to a local ground station. These science and science application objectives are critical today and uniquely addressed by the combined imaging spectroscopy, thermal infrared measurements, and IPM direct broadcast capability of HyspIRI. Two key objectives are: (1) The global HyspIRI spectroscopic measurements of the terrestrial biosphere including vegetation composition and function to constrain and reduce the uncertainty in climate-carbon interactions and terrestrial biosphere feedback. (2) The global 8 band thermal measurements to provide improved constraint of fire related emissions. In this paper the current HyspIRI mission concept that has been reviewed and refined to its current level of maturity with a Data Products Symposium, Science Workshop and NASA HWorkshop is presented including traceability between the measurements and the science and science application objectives.
1,1-Dichloroethylene (1,1-DCE)
Integrated Risk Information System (IRIS)
1,1 - Dichloroethylene ( 1,1 - DCE ) ; CASRN 75 - 35 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments f
Yu, Yi; Feng, Xiaoyan; Vieten, Gertrud; Dippel, Stephanie; Imvised, Tawan; Gueler, Faikah; Ure, Benno M; Kuebler, Jochen F; Klemann, Christian
2017-01-01
Ischemia-reperfusion injury (IRI) is associated with significant patient mortality and morbidity. The complex cascade of IRI is incompletely understood, but inflammation is known to be a key mediator. In addition to the predominant innate immune responses, previous research has also indicated that αβ T cells contribute to IRI in various organ models. The aim of this study was to clarify the role αβ T cells play in IRI to the gut. Adult wild-type (WT) and αβ T cell-deficient mice were subjected to acute intestinal IRI with 30min ischemia followed by 4h reperfusion. The gene expression of pro-inflammatory cytokines was measured by qPCR, and the influx of leukocyte subpopulations in the gut was assessed via flow cytometry and histology. Pro-inflammatory cytokines in the serum were measured, and transaminases were assessed as an indicator of distant organ IRI. Intestinal IRI led to an increased expression of pro-inflammatory cytokines in the gut tissue and an influx of leukocytes that predominantly consisted of neutrophils and macrophages. Furthermore, intestinal IRI increased serum IL-6, TNF-α, and ALT/AST levels. The αβ T cell-deficient mice did not exhibit a more significant increase in pro-inflammatory cytokines in the gut or serum following IR than the WT mice. There was also no difference between WT- and αβ T cell-deficient mice in terms of neutrophil infiltration or macrophage activation. Furthermore, the increase in transaminases was equal in both groups indicating that the level of distant organ injury was comparable. An increasing body of evidence demonstrates that αβ T cells play a key role in IRI. In the gut, however, αβ T cells are not pivotal in the first hours following acute IRI as deficiency does not impact cytokine production, neutrophil recruitment, macrophage activation, or distant organ injury. Thus, αβ T cells may be considered innocent bystanders during the acute phase of intestinal IRI.
Thin cirrus clouds - Seasonal distribution over oceans deduced from Nimbus-4 IRIS
NASA Technical Reports Server (NTRS)
Prabhakara, C.; Fraser, R. S.; Dalu, G.; Wu, Man-Li C.; Curran, R. J.
1988-01-01
Spectral differences in the extinction of the 10.8- and 12.6-micron bands of the IR window region, due to optically thin clouds, were found in the measurements made by both an airborne broadband IR radiometer and the IR interferometer spectrometer (IRIS) aboard the Nimbus-4 satellite; the extinction at 12.6 microns was significantly larger than that at 10.8 microns; both water and ice particles in the clouds can account for such spectral difference in extinction. Multiple scattering radiative transfer calculations of IRIS data revealed this spectral feature about 100 to 20 km away from the high-altitude cold clouds; it is assumed that this feature is related to the spreading of cirrus clouds. Based on this assumption, mean seasonal maps of the distribution of thin cirrus clouds over the oceans were deduced from the IRIS data. The maps show that such clouds are often present over the convectively active areas, such as ITCZ, SPCZ, and the Bay of Bengal during the summer monsoon.
Changes of the eye optics after iris constriction☆
Montés-Micó, Robert; Hernández, Patricio; Fernández-Sánchez, Vicente; Bonaque, Sergio; Lara, Francisco; López-Gil, Norberto
2011-01-01
Purpose To evaluate the possible change in the optics of the human eye after iris constriction. Methods Ocular aberrations were measured under natural viewing conditions in 26 eyes. The measured eyes fixated on a dim target while the contralateral eye was either occluded (so the measured eye had a large pupil) or highly illuminated (so the measured eye had a small pupil). The measured eyes fixated to a dim target placed 0.5 D beyond the subject’s far point. Zernike values obtained in both situations were compared within the same pupil diameter corresponding to the one obtained under the high illumination condition. Results Significant variation in some aberration coefficients were found between the two illumination conditions. Specially, spherical aberration (SA) increased significantly after pupil miosis (P = .0017). The mean increase of SA measured was 0.018 microns, for a 3-mm pupil. Mean values of other ocular aberrations also vary significantly after pupil miosis (changes were larger than the standard deviation of the repeated measurements). A mean paraxial hyperopic shift of one third of diopter was found after iris constriction. Conclusion Iris constriction slightly modifies the optics of the eye. The small hyperopic shift of the best image plane after iris constriction may be explained by a change in the lens shape and/or position.
Karmakar, Suman; Sharma, Surendra K; Vashishtha, Richa; Sharma, Abhishek; Ranjan, Sanjay; Gupta, Deepak; Sreenivas, Vishnubhatla; Sinha, Sanjeev; Biswas, Ashutosh; Gulati, Vinay
2011-01-01
IRIS is an important complication that occurs during management of HIV-TB coinfection and it poses difficulty in diagnosis. Previous studies have reported variable incidence of IRIS. The present study was undertaken to describe the pattern of TB-associated IRIS using recently proposed consensus case-definitions for TB-IRIS for its use in resource-limited settings. A prospective analysis of ART-naïve adults started on HAART from November, 2008 to May, 2010 was done in a tertiary care hospital in north India. A total 224 patients divided into two groups, one with HIV-TB and the other with HIV alone, were followedup for a minimum period of 3 months. The diagnosis of TB was categorised as ''definitive" and ''probable". Out of a total of 224 patients, 203 completed followup. Paradoxical TB-IRIS occurred in 5 of 123 (4%) HIV-TB patients while 6 of 80 (7.5%) HIV patients developed ART-associated TB. A reduction in plasma viral load was significantly (P = .016) associated with paradoxical TB-IRIS. No identifiable risk factors were associated with the development of ART-associated TB. The consensus case-definitions are useful tools in the diagnosis of TB-associated IRIS. High index of clinical suspicion is required for an early diagnosis.
Szabó, Antal; Papp, András; Borbándy, Ágnes; D Géhl, Zsuzsanna; Nagy, Zoltán Zsolt; Resch, Miklós
2017-01-01
The correction of aphakia might be a challenge for the surgeon. The aim of this study is to describe the authors' experience with the implantation of the retropupillary iris clip intraocular lens. Patients between January 2014 and December 2015 were included in the retrospective study. Retropupillary implantation of iris clip intraocular lens VRSA 54 (AMO Advanced Medical Optics, USA) was performed in all cases. The minimum follow up period was three months. The stability of the intraocular lens and the intraoperative and postoperative complications and the visual acuity were evaluated. During this time period 11 cases (1 female, 10 males) were included in the study. The mean age at the time of the implantation was 57.7 years (between 25-74 years). In 4 cases the iris clip lens was implanted during the first intervention, in 7 cases during the secondary procedure. In all cases the lens was fixated onto the iris posteriorly. The best corrected visual acuity before the iris clip implantation was 0.43 (0.1-1.0) and postoperatively at the time of the follow up 0.49 (0.04-1.0). With the use of the retropupillary implanted iris clip intraocular lens all of the patients could have been rehabilitated without major complications. Orv. Hetil., 2017, 158(1), 20-24.
Remote Sensing of Ionosphere by IONOLAB Group
NASA Astrophysics Data System (ADS)
Arikan, Feza
2016-07-01
Ionosphere is a temporally and spatially varying, dispersive, anisotropic and inhomogeneous medium that is characterized primarily by its electron density distribution. Electron density is a complex function of spatial and temporal variations of solar, geomagnetic, and seismic activities. Ionosphere is the main source of error for navigation and positioning systems and satellite communication. Therefore, characterization and constant monitoring of variability of the ionosphere is of utmost importance for the performance improvement of these systems. Since ionospheric electron density is not a directly measurable quantity, an important derivable parameter is the Total Electron Content (TEC), which is used widely to characterize the ionosphere. TEC is proportional to the total number of electrons on a line crossing the atmosphere. IONOLAB is a research group is formed by Hacettepe University, Bilkent University and Kastamonu University, Turkey gathered to handle the challenges of the ionosphere using state-of-the-art remote sensing and signal processing techniques. IONOLAB group provides unique space weather services of IONOLAB-TEC, International Reference Ionosphere extended to Plasmasphere (IRI-Plas) model based IRI-Plas-MAP, IRI-Plas-STEC and Online IRI-Plas-2015 model at www.ionolab.org. IONOLAB group has been working for imaging and monitoring of ionospheric structure for the last 15 years. TEC is estimated from dual frequency GPS receivers as IONOLAB-TEC using IONOLAB-BIAS. For high spatio-temporal resolution 2-D imaging or mapping, IONOLAB-MAP algorithm is developed that uses automated Universal Kriging or Ordinary Kriging in which the experimental semivariogram is fitted to Matern Function with Particle Swarm Optimization (PSO). For 3-D imaging of ionosphere and 1-D vertical profiles of electron density, state-of-the-art IRI-Plas model based IONOLAB-CIT algorithm is developed for regional reconstruction that employs Kalman Filters for state/temporal transition. IONOLAB group contributes to remote sensing of upper atmosphere, ionosphere and plasmasphere with continuing TUBITAK projects. IONOLAB group is open to joint research and collaboration with researchers from all disciplines that investigate the challenges of ionosphere and space weather. This study is supported by TUBITAK 114E541, 115E915 and Joint TUBITAK 114E092 and AS CR 14/001 projects.
Zhan, Xi; Zhang, Zhiqing; Huang, Hanfei; Zhang, Yujun; Zeng, Zhong
2018-06-01
To investigate the effect of heme oxygenase-1 (HO-1) on the ischemic reperfusion injury (IRI) of bile duct in rat models after liver transplantation. 320 SD rats were equally and randomly divided into 5 groups, which were group A receiving injection of 3×10 8 /pfu/ml adenovirus (adv), group B with donor receiving Adv-HO-1 and recipient receiving Adv-HO-1-siRNA, group C with donor and recipient both receiving Adv-HO-1, group D with donor receiving Adv-HO-1-siRNA and recipient receiving Adv-HO-1, and group E with donor and recipient both receiving Adv-HO-1-siRNA at 24h before liver transplantation. Donor liver was stored in UW liquid at 4°C followed by measuring HO-1 level by western blot before transplantation. On d1, d3, d7 and d14, serum and liver was isolated for analysis of liver function, inflammatory cell infiltration by H&E staining, ultrastructure of liver by transmission electron microscopy as well as the expression of HO-1, Bsep, Mrp2 and Ntcp by western blot. Compared with group D and E, group B and C displayed improved liver function as demonstrated by lower level of ALT, AST, LDH, TBIL, ALP and GGT, increased secretion of TBA and PL as well as expression of transporter proteins (Bsep, Mrp2 and Ntcp), reduced inflammatory cells infiltration and liver injury. Our study demonstrated that overexpression of HO-1 in donor liver can ameliorate the damage to bile duct and liver, and improved liver function, suggesting HO-1 might be a new therapeutic target in the treatment of IRI after liver transplantation. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
IRIS Toxicological Review of Chloroprene (Peer Review Plan) ...
Chloroprene (C4H5Cl; 2-chloro-1,3-butadiene, CASRN 126-99-8) is a volatile, flammable liquid monomer used exclusively in the manufacture of neoprene (polychloroprene) elastomer which is used to make diverse products such as belts, hoses, gloves, wire coatings, and tubing. Chloroprene has a high vapor pressure, readily evaporates from water and solid surfaces, and readily oxidizes and form dimers and other oxygenated species in the absence of stabilizers (e.g., phenothiazine). When released to soil it may leach into groundwater, but breakdown via hydrolysis is not likely. Absorption into the body is possible through the lungs, gastrointestinal tract, or skin, and widespread distribution is evidenced by many target sites exhibiting effects. EPA has not developed an assessment of the potential for human health effects from exposure to chloroprene. Initial stages of development for this assessment are underway. The assessment is likely to include an oral reference value (RfD), an inhalation reference value (RfC), and a carcinogenicity assessment. Chloroprene will be entered into IRIS. IRIS is the Agency-approved source of toxicological and risk information accessible to the public, EPA regional offices, state governments and EPA regulatory program offices. This evaluation supports the Office of Air Quality Planning and Standards-Office of Air and Radiation in assessing the hazardous effects of chemicals that are listed as the greatest threat to the public
NASA Astrophysics Data System (ADS)
Bhuyan, Pradip; Yokoyama, Tatsuhiro; Supnithi, Pornchai; Kalita, Bitap Raj; Wang, Kehe; Komolmis, Tharadol; Yatini, Clara
2016-07-01
The performance of the IRI 2012 model is examined for the double peaked solar cycle 24 in the low latitude region of 90-130oE longitude in the context of the global longitudinal wave number four structure (WN4). The monthly mean values of the foF2 and the hmF2(if available) measurements at low and low mid-latitude stations Dibrugarh (27.5°N, 95°E), Hainan (19.2°N,109.7°E),Okinawa (26.5°N,128°E) and Cocos Island (12.2°S,96.8°E) during quiet times and Dibrugarh (27.5°N, 95°E), Chiang Mai (18.76°N,98.93°E), Chumphon (10.72°N,99.37°E), Kototabang (0.2°S,100.32°E) and Cocos Island (12.2°S,96.8°E ) during the disturbed days of a severe geomagnetic storm are investigated. These stations are located under the strongest peak of the longitudinal WN4 structure in NmF2 along 90-130°E longitudes. The IRI is quite successful in predicting the seasonal averages of NmF2 over this region except in the equinox afternoon period where IRI underestimates the NmF2 in low latitudes. When the monthly mean measured data is compared with IRI, the difference between the IRI model predictions and the measurements are found to follow a systematic pattern. The IRI-2012 with CCIR options slightly underestimates foF2 over Dibrugarh in day time and overestimates in the night time. The amount of underestimation varies from month to month and also depends on the solar activity levels. The IRI also underestimated the day time hmF2 and overestimated the night time hmF2 over Dibrugarh. In case of Hainan, the IRI overestimates the NmF2 in the equinox months and generally in the afternoon to post sunset period. The model values are closer in the solstice than in the equinox. In Okinawa, the trend reverses and the IRI overestimates the NmF2 in the day time and underestimates in the night time. The IRI overestimated the day time hmF2 and underestimated the night time hmF2 over Okinawa. In case of Cocos Island which lies almost on the EIA anomaly region of the southern hemisphere, IRI underestimates the peak day time NmF2 in most months. The measurements are closer to the model values in the forenoon period and in the low solar activity period. The striking feature across all the stations is the IRI underestimation of the post sunset enhancement of NmF2 in low latitudes. During the severe geomagnetic storm of 17-18 March, 2015, the IRI was not able to replicate the inhibition of EIA on the next day i.e. 18 March as observed in the 100°E longitude.
Roade Tato, Luisa; Burgos Cibrian, Joaquín; Curran Fábregas, Adrià; Navarro Mercadé, Jordi; Willekens, Rein; Martín Gómez, María Teresa; Ribera Pascuet, Esteban; Falcó Ferrer, Vicenç
2017-11-26
The incidence of immune reconstitution inflammatory syndrome (IRIS) in HIV-infected patients after an episode of Pneumocystis jirovecii pneumonia (PJP) seems to be lower than with other opportunistic infections. We conducted an observational study in order to determine the incidence, clinical characteristics and outcome of patients diagnosed with PJP-related IRIS. We conducted an observational study of HIV patients diagnosed with PJP-related IRIS from January 2000 to November 2015. We analyzed epidemiological and clinical characteristics as well as laboratory findings. We also carried out a systematic review of published cases. Six cases of IRIS out of 123 (4.9%) HIV-infected patients with PJP who started ART were diagnosed. All six cases were men with a median age of 34 (IQR: 8) years. The six patients developed paradoxical IRIS. Subjects younger than 40 years old (p=0.084) and with an HIV-RNA viral load >100000 copies/ml (p=0.081) at diagnosis showed a tendency to develop IRIS. Thirty-seven published cases of PJP-related IRIS were identified. Although 51% of cases involved respiratory failure, no deaths were reported. PJP-related IRIS is rare condition compared to other opportunistic infections. It can lead to a severe respiratory failure in a significant proportion of cases, although no deaths have been reported. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
2014-01-01
Background Renal ischemia-reperfusion injury (IRI) increases the rates of acute kidney failure, delayed graft function, and early mortality after kidney transplantation. The pathophysiology involved includes oxidative stress, mitochondrial dysfunction, and immune-mediated injury. The anti-oxidation, anti-apoptosis, and anti-inflammation properties of baicalin, a flavonoid glycoside isolated from Scutellaria baicalensis, have been verified. This study therefore assessed the effects of baicalin against renal IRI in rats. Methods Baicalin was intraperitoneally injected 30 min before renal ischemia. Serum and kidneys were harvested 24 h after reperfusion. Renal function and histological changes were assessed. Markers of oxidative stress, the Toll-like receptor (TLR)2 and TLR4 signaling pathway, mitochondrial stress, and cell apoptosis were also evaluated. Results Baicalin treatment decreased oxidative stress and histological injury, and improved kidney function, as well as inhibiting proinflammatory responses and tubular apoptosis. Baicalin pretreatment also reduced the expression of TLR2, TLR4, MyD88, p-NF-κB, and p-IκB proteins, as well as decreasing caspase-3 activity and increasing the Bcl-2/Bax ratio. Conclusions Baicalin may attenuate renal ischemia-reperfusion injury by inhibiting proinflammatory responses and mitochondria-mediated apoptosis. These effects are associated with the TLR2/4 signaling pathway and mitochondrial stress. PMID:24417870
Lin, Miao; Li, Long; Li, Liping; Pokhrel, Gaurab; Qi, Guisheng; Rong, Ruiming; Zhu, Tongyu
2014-01-13
Renal ischemia-reperfusion injury (IRI) increases the rates of acute kidney failure, delayed graft function, and early mortality after kidney transplantation. The pathophysiology involved includes oxidative stress, mitochondrial dysfunction, and immune-mediated injury. The anti-oxidation, anti-apoptosis, and anti-inflammation properties of baicalin, a flavonoid glycoside isolated from Scutellaria baicalensis, have been verified. This study therefore assessed the effects of baicalin against renal IRI in rats. Baicalin was intraperitoneally injected 30 min before renal ischemia. Serum and kidneys were harvested 24 h after reperfusion. Renal function and histological changes were assessed. Markers of oxidative stress, the Toll-like receptor (TLR)2 and TLR4 signaling pathway, mitochondrial stress, and cell apoptosis were also evaluated. Baicalin treatment decreased oxidative stress and histological injury, and improved kidney function, as well as inhibiting proinflammatory responses and tubular apoptosis. Baicalin pretreatment also reduced the expression of TLR2, TLR4, MyD88, p-NF-κB, and p-IκB proteins, as well as decreasing caspase-3 activity and increasing the Bcl-2/Bax ratio. Baicalin may attenuate renal ischemia-reperfusion injury by inhibiting proinflammatory responses and mitochondria-mediated apoptosis. These effects are associated with the TLR2/4 signaling pathway and mitochondrial stress.
Tachado, S D; Zhang, Y; Abdel-Latif, A A
1993-05-01
To examine the mechanisms underlying the effects of PGF2 alpha receptor desensitization on agonist-induced second messenger formation and contraction in bovine iris sphincter. Short-term PGF2 alpha receptor desensitization of the bovine iris sphincter was carried out by incubating the tissue in Krebs-Ringer bicarbonate buffer containing 25 microM PGF2 alpha for 45 min at 37 degrees C. The effects of PGF2 alpha and other pharmacologic agents on inositol 1,4,5-triphosphate (IP3) production and cyclic adenosine monophosphate (cAMP) formation in desensitized and nondesensitized tissues were monitored by anion-exchange chromatography and radioimmunoassay. In the isolated bovine iris sphincter, protein kinase C (PKC) is involved in the activation of adenylate cyclase and the desensitization of prostaglandin F2 alpha receptor-mediated responses supported by these findings. (A) Exposure of the tissue to phorbol 12,13-dibutyrate, used to activate PKC, enhanced basal cAMP formation in a dose (EC50 = 8.8 x 10(-8) M) and time (t1/2 = 7.5 min) dependent manner. Phorbol 12,13-dibutyrate increased cAMP levels by twofold and it potentiated the isoproterenol-induced cAMP formation. The biologically inactive phorbol ester, 4 alpha-phorbol had no effect. Staurosporine, a potent PKC inhibitor, inhibited phorbol 12,13-dibutyrate-induced cAMP formation in a dose-dependent manner (IC50 of 0.25 microM). The increase in cAMP levels by phorbol 12,13-dibutyrate results from stimulation of adenylate cyclase, rather than from inhibition of cAMP phosphodiesterase, and it is not mediated through Ca2+ mobilization. Pretreatment of the tissue with phorbol 12,13-dibutyrate inhibited IP3 production in response to PGF2 alpha. (B) Desensitization of the sphincter with PGF2 alpha for 45 min increased cAMP formation and attenuated IP3 production and contraction. The effects of PGF2 alpha desensitization were reversed by pretreatment of the tissue with staurosporine. Down-regulation of PKC prevented the PGF2 alpha-stimulated increase in cAMP formation. In the desensitized tissue, diacylglycerol, the endogenous activator of PKC, may arise from phosphatidylcholine, via phospholipase D. (A) Activation of PKC in the bovine iris sphincter leads to stimulation of adenylate cyclase and to an increase in cAMP formation. The cAMP formed inhibits IP3 production and muscle contraction. (B) PGF2 alpha desensitization results in adenylate cyclase activation, mediated through PKC. (C) PGF2 alpha desensitization could uncouple the receptor from the Gq and Gi proteins and enhance PG stimulation of adenylate cyclase activity through the Gs protein. (D) Uncoupling of the G proteins from the PG receptor and activation of PKC, both of which result in enhanced cAMP formation, may underlie the mechanism of PGF2 alpha desensitization. (E) These observations demonstrate "cross talk" between the two second messenger systems and their physiologic consequences.
NASA Astrophysics Data System (ADS)
Newman, R. L.
2002-12-01
How many images can you display at one time with Power Point without getting "postage stamps"? Do you have fantastic datasets that you cannot view because your computer is too slow/small? Do you assume a few 2-D images of a 3-D picture are sufficient? High-end visualization centers can minimize and often eliminate these problems. The new visualization center [http://siovizcenter.ucsd.edu] at Scripps Institution of Oceanography [SIO] immerses users into a virtual world by projecting 3-D images onto a Panoram GVR-120E wall-sized floor-to-ceiling curved screen [7' x 23'] that has 3.2 mega-pixels of resolution. The Infinite Reality graphics subsystem is driven by a single-pipe SGI Onyx 3400 with a system bandwidth of 44 Gbps. The Onyx is powered by 16 MIPS R12K processors and 16 GB of addressable memory. The system is also equipped with transmitters and LCD shutter glasses which permit stereographic 3-D viewing of high-resolution images. This center is ideal for groups of up to 60 people who can simultaneously view these large-format images. A wide range of hardware and software is available, giving the users a totally immersive working environment in which to display, analyze, and discuss large datasets. The system enables simultaneous display of video and audio streams from sources such as SGI megadesktop and stereo megadesktop, S-VHS video, DVD video, and video from a Macintosh or PC. For instance, one-third of the screen might be displaying S-VHS video from a remotely-operated-vehicle [ROV], while the remaining portion of the screen might be used for an interactive 3-D flight over the same parcel of seafloor. The video and audio combinations using this system are numerous, allowing users to combine and explore data and images in innovative ways, greatly enhancing scientists' ability to visualize, understand and collaborate on complex datasets. In the not-distant future, with the rapid growth in networking speeds in the US, it will be possible for Earth Sciences Departments to collaborate effectively while limiting the amount of physical travel required. This includes porting visualization content to the popular, low-cost Geowall visualization systems, and providing web-based access to databanks filled with stock geoscience visualizations.
Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX)
Integrated Risk Information System (IRIS)
Hexahydro - 1,3,5 - trinitro - 1,3,5 - triazine ( RDX ) ; CASRN 121 - 82 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health
NASA Technical Reports Server (NTRS)
Vanous, D. D.
1974-01-01
The development and characteristics of the infrared interferometer spectrometer and radiometer (IRIS) instrument for use with the Mariner/Jupiter/Saturn space probe. The subjects discussed are: (1) the electronic design, (2) the opto-mechanical design, (3) reliability analysis, (4) quality control, and (5) program management.
The Inversion of Ionospheric/plasmaspheric Electron Density From GPS Beacon Observations
NASA Astrophysics Data System (ADS)
Zou, Y. H.; Xu, J. S.; Ma, S. Y.
It is a space-time 4-D tomography to reconstruct ionospheric/ plasmaspheric elec- tron density, Ne, from ground-based GPS beacon measurements. The mathematical foundation of such inversion is studied in this paper and some simulation results of reconstruction for GPS network observation are presented. Assuming reasonably a power law dependence of NE on time with an index number of 1-3 during one ob- servational time of GPS (60-90min.), 4-D inversion in consideration is reduced to a 3-D cone-beam tomography with incomplete projections. To see clearly the effects of the incompleteness on the quality of reconstruction for 3-D condition, we deduced theoretically the formulae of 3-D parallel-beam tomography. After establishing the mathematical basis, we adopt linear temporal dependence of NE and voxel elemental functions to perform simulation of NE reconstruction with the help of IRI90 model. Reasonable time-dependent 3-D images of ionosphere/ plasmasphere electron density distributions are obtained when taking proper layout of the GPS network and allowing variable resolutions in vertical.
Multi-image encryption based on synchronization of chaotic lasers and iris authentication
NASA Astrophysics Data System (ADS)
Banerjee, Santo; Mukhopadhyay, Sumona; Rondoni, Lamberto
2012-07-01
A new technique of transmitting encrypted combinations of gray scaled and chromatic images using chaotic lasers derived from Maxwell-Bloch's equations has been proposed. This novel scheme utilizes the general method of solution of a set of linear equations to transmit similar sized heterogeneous images which are a combination of monochrome and chromatic images. The chaos encrypted gray scaled images are concatenated along the three color planes resulting in color images. These are then transmitted over a secure channel along with a cover image which is an iris scan. The entire cryptology is augmented with an iris-based authentication scheme. The secret messages are retrieved once the authentication is successful. The objective of our work is briefly outlined as (a) the biometric information is the iris which is encrypted before transmission, (b) the iris is used for personal identification and verifying for message integrity, (c) the information is transmitted securely which are colored images resulting from a combination of gray images, (d) each of the images transmitted are encrypted through chaos based cryptography, (e) these encrypted multiple images are then coupled with the iris through linear combination of images before being communicated over the network. The several layers of encryption together with the ergodicity and randomness of chaos render enough confusion and diffusion properties which guarantee a fool-proof approach in achieving secure communication as demonstrated by exhaustive statistical methods. The result is vital from the perspective of opening a fundamental new dimension in multiplexing and simultaneous transmission of several monochromatic and chromatic images along with biometry based authentication and cryptography.
Kasarjian, Julie K. A.; Hidaka, Masumi; Horiuchi, Takashi; Iida, Masatake; Ryu, Junichi
2004-01-01
Using an in vivo plasmid transformation method, we have determined the DNA sequences recognized by the KpnAI, StySEAI, StySENI and StySGI R-M systems from Klebsiella oxytoca strain M5a1, Salmonella eastbourne, Salmonella enteritidis and Salmonella gelsenkirchen, respectively. These type I restriction-modification systems were originally identified using traditional phage assay, and described here is the plasmid transformation test and computer program used to determine their DNA recognition sequences. For this test, we constructed two sets of plasmids, pL and pE, that contain phage lambda and Escherichia coli K-12 chromosomal DNA fragments, respectively. Further, using the methylation sensitivities of various known type II restriction enzymes, we identified the target adenines for methylation (listed in bold italics below as A or T in case of the complementary strand). The recognition sequence and methylation sites are GAA(6N)TGCC (KpnAI), ACA(6N)TYCA (StySEAI), CGA(6N)TACC (StySENI) and TAAC(7N)RTCG (StySGI). These DNA recognition sequences all have a typical type I bipartite pattern and represent three novel specificities and one isoschizomer (StySENI). For confirmation, oligonucleotides containing each of the predicted sequences were synthesized, cloned into plasmid pMECA and transformed into each strain, resulting in a large reduction in efficiency of transformation (EOT). PMID:15199175
Karmakar, Suman; Sharma, Surendra K.; Vashishtha, Richa; Sharma, Abhishek; Ranjan, Sanjay; Gupta, Deepak; Sreenivas, Vishnubhatla; Sinha, Sanjeev; Biswas, Ashutosh; Gulati, Vinay
2011-01-01
Background & Objective. IRIS is an important complication that occurs during management of HIV-TB coinfection and it poses difficulty in diagnosis. Previous studies have reported variable incidence of IRIS. The present study was undertaken to describe the pattern of TB-associated IRIS using recently proposed consensus case-definitions for TB-IRIS for its use in resource-limited settings. Methods. A prospective analysis of ART-naïve adults started on HAART from November, 2008 to May, 2010 was done in a tertiary care hospital in north India. A total 224 patients divided into two groups, one with HIV-TB and the other with HIV alone, were followedup for a minimum period of 3 months. The diagnosis of TB was categorised as ‘‘definitive” and ‘‘probable”. Results. Out of a total of 224 patients, 203 completed followup. Paradoxical TB-IRIS occurred in 5 of 123 (4%) HIV-TB patients while 6 of 80 (7.5%) HIV patients developed ART-associated TB. A reduction in plasma viral load was significantly (P = .016) associated with paradoxical TB-IRIS. No identifiable risk factors were associated with the development of ART-associated TB. Conclusion. The consensus case-definitions are useful tools in the diagnosis of TB-associated IRIS. High index of clinical suspicion is required for an early diagnosis. PMID:21197457
1993-09-28
APPENDIX B COKPILATIC SYS=Dl OPTI•CS APPENDIX C APPEN4DIX F OF THE Aa STANDRD CHNMP1 1 The a implementation described above was tested according to the Mad...REPORT and CHEK FILE is checked by a set of executable tests. If these units are not opirating correctly, validation testing is discontinued. Class B...sections 2.1 and 2.2 (counted in items b and f , below). 3-1 PC0SSmnG INO nON a) Total Number of Applicable Tests 3809 b) Total Number of Withdrawn Tests
Exogenous Oct-4 Inhibits Lens Transdifferentiation in the Newt Notophthalmus viridescens
Bhavsar, Rital B.; Tsonis, Panagiotis A.
2014-01-01
From the cocktail of four factors that were able to induce pluripotent stem cells from differentiated cells, Oct-4, c-Myc, Sox-2 and Klf4, only Oct-4 was not expressed during regeneration in newts. To explore the possible action of this stemness factor we developed an assay where we introduced exogenous Oct-4 protein to an in vitro system for lens regeneration in newts. We found that exogenous Oct-4 inhibits differentiation of iris pigmented epithelial cells into lens cells and also regulates Sox-2 and Pax-6, both important players during lens development. Thus, presence of Oct-4 hinders transdifferentiation of iris cells. PMID:25019378
Pelzer, Uwe; Blanc, Jean-Frédéric; Melisi, Davide; Cubillo, Antonio; Von Hoff, Daniel D; Wang-Gillam, Andrea; Chen, Li-Tzong; Siveke, Jens T; Wan, Yin; Solem, Caitlyn T; Botteman, Marc F; Yang, Yoojung; de Jong, Floris A; Hubner, Richard A
2017-05-09
In the NAPOLI-1 Phase 3 trial, nal-IRI+5-fluorouracil and leucovorin (5-FU/LV) significantly improved median overall survival (6.1 vs 4.2 months, P=0.012) and progression-free survival (3.1 vs 1.5 months, P=0.0001) vs 5-FU/LV alone in metastatic pancreatic adenocarcinoma patients previously treated with gemcitabine-based therapy. This analysis evaluated between treatment differences in quality-adjusted time without symptoms of disease progression or toxicity (Q-TWiST). Overall survival was partitioned into time with grade ⩾3 toxicity (TOX), disease progression (REL), and time without disease progression symptoms or grade ⩾3 toxicity (TWiST). Mean Q-TWiST was calculated by weighting time spent by a utility of 1.0 for TWiST and 0.5 for TOX and REL. In threshold analyses, utility for TOX and REL were varied from 0.0 to 1.0. Patients in nal-IRI+5-FU/LV (n=117) vs 5-FU/LV (n=119) had significantly more mean time in TWiST (3.4 vs 2.4 months) and TOX (1.0 vs 0.3 months) but similar REL (2.5 vs 2.7 months). In the base case, nal-IRI+5-FU/LV patients had 1.3 months (95% CI, 0.4-2.1; 5.1 vs 3.9) greater Q-TWiST (threshold analyses range: 0.9-1.6 months). Within NAPOLI-1, nal-IRI+5-FU/LV resulted in statistically significant and clinically meaningful gains in quality-adjusted survival vs 5-FU/LV alone.
NASA Astrophysics Data System (ADS)
Mengistu, E.; Damtie, B.; Moldwin, M. B.; Nigussie, M.
2018-03-01
This paper examines the performances of NeQuick2, the latest available IRI-2016, IRI-2012 and IRI-2007 models in describing the monthly and seasonal mean total electron content (TEC) over the East African region. This is to gain insight into the success of the various model types and versions at characterizing the ionosphere within the equatorial ionization anomaly. TEC derived from five Global Positioning System (GPS) receivers installed at Addis Ababa (ADD, 5.33°N, 111.99°E Geog.), Asab (ASAB, 8.67°N, 116.44°E Geog.), Ambo (ABOO, 5.43°N, 111.05°E Geog.), Nairobi (RCMN, -4.48°N, 108.46°E Geog.) and Nazret (NAZR, 4.78°N, 112.43°E Geog.), are compared with the corresponding values computed using those models during varying solar activity period (1998 and 2008-2015). We found that different models describe the equatorial and anomaly region ionosphere best depending on solar cycle, season and geomagnetic activity levels. Our results show that IRI-2016 is the best model (compared to others in terms of discrepancy range) in estimating the monthly mean GPS-TEC at NAZR, ADD and RCMN stations except at ADD during 2008 and 2012. It is also found that IRI-2012 is the best model in estimating the monthly mean TEC at ABOO station in 2014. IRI show better agreement with observations during June solstice for all the years studied at ADD except in 2012 where NeQuick2 better performs. At NAZR, NeQuick2 better performs in estimating seasonal mean GPS-TEC during 2011, while IRI models are best during 2008-2009. Both NeQuick2 and IRI models underestimate measured TEC for all the seasons at ADD in 2010 but overestimate at NAZR in 2009 and RCMN in 2008. The periodic variations of experimental and modeled TEC have been compared with solar and geomagnetic indices at ABOO and ASAB in 2014 and results indicate that the F10.7 and sunspot number as indices of solar activity seriously affects the TEC variations with periods of 16-32 days followed by the geomagnetic activity on shorter timescales (roughly periods of less than 16 days). In this case, NeQuick2 derived TEC shows better agreement with a long term period variations of GPS-TEC, while IRI-2016 and IRI-2007 show better agreement with observations during short term periodic variations. This indicates that the dependence of NeQuick2 derived TEC on F10.7 is seasonal. Hence, we suggest that representation of geomagnetic activity indices is required for better performance over the low latitude region.
Sequences associated with human iris pigmentation.
Frudakis, Tony; Thomas, Matthew; Gaskin, Zach; Venkateswarlu, K; Chandra, K Suresh; Ginjupalli, Siva; Gunturi, Sitaram; Natrajan, Sivamani; Ponnuswamy, Viswanathan K; Ponnuswamy, K N
2003-01-01
To determine whether and how common polymorphisms are associated with natural distributions of iris colors, we surveyed 851 individuals of mainly European descent at 335 SNP loci in 13 pigmentation genes and 419 other SNPs distributed throughout the genome and known or thought to be informative for certain elements of population structure. We identified numerous SNPs, haplotypes, and diplotypes (diploid pairs of haplotypes) within the OCA2, MYO5A, TYRP1, AIM, DCT, and TYR genes and the CYP1A2-15q22-ter, CYP1B1-2p21, CYP2C8-10q23, CYP2C9-10q24, and MAOA-Xp11.4 regions as significantly associated with iris colors. Half of the associated SNPs were located on chromosome 15, which corresponds with results that others have previously obtained from linkage analysis. We identified 5 additional genes (ASIP, MC1R, POMC, and SILV) and one additional region (GSTT2-22q11.23) with haplotype and/or diplotypes, but not individual SNP alleles associated with iris colors. For most of the genes, multilocus gene-wise genotype sequences were more strongly associated with iris colors than were haplotypes or SNP alleles. Diplotypes for these genes explain 15% of iris color variation. Apart from representing the first comprehensive candidate gene study for variable iris pigmentation and constituting a first step toward developing a classification model for the inference of iris color from DNA, our results suggest that cryptic population structure might serve as a leverage tool for complex trait gene mapping if genomes are screened with the appropriate ancestry informative markers. PMID:14704187
Sheashaa, Hussein; Lotfy, Ahmed; Elhusseini, Fatma; Aziz, Azza Abdel; Baiomy, Azza; Awad, Samah; Alsayed, Aziza; El-Gilany, Abdel-Hady; Saad, Mohamed-Ahdy A A; Mahmoud, Khaled; Zahran, Faten; Salem, Dalia A; Sarhan, Ahmed; Ghaffar, Hassan Abdel; Sobh, Mohamed
2016-05-01
Acute kidney injury (AKI) is a complex clinical condition associated with significant morbidity and mortality and lacking effective management. Ischemia-reperfusion injury (IRI) remains one of the leading causes of AKI in native and transplanted kidneys. The aim of this study was to evaluate the efficacy of adipose-derived mesenchymal stem cells (ADSCs) in the prevention of renal IRI in rats. The study was conducted on male Sprague-Dawley rats (n=72) weighing 250-300 g. Rats were randomly assigned to three main groups: i) Sham-operated control group (n=24); ii) positive control group, in which rats were subjected to IRI and were administered culture media following 4 h of IRI (n=24); and iii) ADSC group (n=24), in which rats were administered 1×10 6 ADSCs via the tail vein following 4 h of IRI. Each main group was further divided according to the timing after IRI into four equal-sized subgroups. Renal function was tested via the measurement of serum creatinine levels and creatinine clearance. In addition, malondialdehyde (MDA) levels were determined in serum and renal tissue homogenate as an indicator of oxidative stress. Histopathological changes were analyzed in different regions of the kidney, namely the cortex, outer stripe of the outer medulla (OSOM), inner stripe of the outer medulla (ISOM) and inner medulla. In each region, the scoring system considered active injury changes, regenerative changes and chronic changes. The ADSCs were assessed and their differentiation capability was verified. IRI resulted in a significant increase in serum creatinine, serum and tissue MDA levels and a significant reduction in creatinine clearance compared with those in sham-operated rats,. These changes were attenuated by the use of ADSCs. The prominent histopathological changes in the cortex, ISOM and OSOM were reflected in the injury score, which was significantly evident in the positive control group. The use of ADSCs was associated with significantly lowered injury scores at days 1 and 3; however, no significant effect was observed on day 7. These results indicate that the use of ADSCs ameliorates renal injury and dysfunction associated with IRI in rats.
NASA Technical Reports Server (NTRS)
Carlson, Barbara E.; Lacis, Andrew A.; Rossow, William B.
1992-01-01
The Voyager IRIS spectra of the Jovian North Equatorial Belt (NEB) hot spots are reanalyzed using a radiative transfer model which includes the full effects of anisotropic multiple scattering by clouds. The atmospheric model includes the three thermochemically predicted cloud layers, NH3, NH4SH, and H2O. Spectrally dependent cloud extinction is modeled using Mie theory and the refractive indices of NH3 ice, NH4SH ice, water, and H2O ice. The upper tropospheric temperature profile, gas abundances, height-dependent parahydrogen profile, and vertical distribution of NH3 cloud opacity are retrieved from an analysis of the far-infrared (180-1200/cm) IRIS observations. With these properties constrained, the 5-micron (1800-2300/cm) observations are analyzed to determine the atmospheric and cloud structure of the deeper atmosphere (P of greater than 1.5 bars). The results show that the abundance of water is at least 1.5 times solar with 2 times solar (0.00276 mixing ratio relative to H2) providing the best-fit to the Voyager IRIS hot spot observations.
Zhou, Yong; Zeng, Nan; Ji, Yanhong; Li, Yao; Dai, Xiangsong; Li, Peng; Duan, Lian; Ma, Hui; He, Yonghong
2011-01-01
We present a method of glucose concentration detection in the anterior chamber with a differential absorption optical low-coherent interferometry (LCI) technique. Back-reflected light from the iris, passing through the anterior chamber twice, was selectively obtained with the LCI technique. Two light sources, one centered within (1625 nm) and the other centered outside (1310 nm) of a glucose absorption band were used for differential absorption measurement. In the eye model and pig eye experiments, we obtained a resolution glucose level of 26.8 mg/dL and 69.6 mg/dL, respectively. This method has a potential application for noninvasive detection of glucose concentration in aqueous humor, which is related to the glucose concentration in blood. PMID:21280906
NASA Astrophysics Data System (ADS)
Woodward, R.; Frassetto, A.; Meltzer, A.
2017-12-01
The recent SZ4D Initiative community vision document recognizes the potential to focus community resources on studying subduction processes along, for example, the Pacific margin of South America. Preexisting geophysical infrastructure can play a vital role in establishing such new observational capabilities. For example, an SZ4D backbone observing capability could be established in South America by leveraging existing stations in the region. Such relevant existing seismic and geodetic stations, operated as part of local or national networks in South America, have been identified as a result of recent international collaborations with IRIS and others. Here we discuss the concept and experience of leveraging existing infrastructure in major new observational programs, outline the state of geophysical networks in South America (emphasizing current seismic networks but also looking back on historical temporary deployments), and provide an overview of potential scientific targets in the Americas that encompass a sampling of recently produced research results and datasets. Additionally, we reflect on strategies for establishing meaningful collaborations across South America and elsewhere, an aspect that will be critical to the international partnerships, and associated capacity building, needed for an internationally inclusive and collaborative SZ4D activity.
Sierra-Madero, Juan G; Ellenberg, Susan S; Rassool, Mohammed S; Tierney, Ann; Belaunzarán-Zamudio, Pablo F; López-Martínez, Alondra; Piñeirúa-Menéndez, Alicia; Montaner, Luis J; Azzoni, Livio; Benítez, César Rivera; Sereti, Irini; Andrade-Villanueva, Jaime; Mosqueda-Gómez, Juan L; Rodriguez, Benigno; Sanne, Ian; Lederman, Michael M
2014-11-01
Immune reconstitution inflammatory syndrome (IRIS) is a common complication of antiretroviral therapy (ART) in patients with HIV. IRIS is associated with an increased risk of admission to hospital and death. We assessed whether CCR5 blockade with maraviroc reduces the risk of IRIS. The CADIRIS study was a double-blind, randomised, placebo-controlled trial that recruited participants from five clinical sites in Mexico and one in South Africa and followed them for 1 year. Patients were eligible if they were adults with HIV, who were naive to ART, had CD4 count lower than 100 cells per μL and HIV RNA greater than 1000 copies per mL. Participants were randomly assigned (1:1) by permuted block randomisation to receive either maraviroc (600 mg twice daily) or placebo in addition to an ART regimen that included tenofovir, emtricitabine, and efavirenz for 48 weeks. Patients, care providers, and members of the research team were masked to treatment allocation. Clinical and laboratory evaluations were done at baseline, and weeks 2, 4, 8, 12, 16, 24, 48, and 60. The primary outcome was time to an IRIS event by 24 weeks. All patients who were randomly assigned contributed to the primary time-to-event analysis from the date of ART initiation until week 24, the time of an IRIS event or death. This trial is registered with ClinicalTrials.gov, number NCT00988780. Between Dec 10, 2009, and Jan 17, 2012, we screened 362 patients; of whom 279 met the inclusion criteria and three refused to participate; thus 276 participants were randomly assigned (140 to receive maraviroc and 136 to receive placebo). 64 (23%) patients had IRIS events, 33 (24%) in the maraviroc group and 31 (23%) in the placebo group (p=0·74). No difference in the time to IRIS events was noted between the treatment groups (HR 1·08, 95% CI 0·66-1·77; log-rank test p=0·74). 37 participants (26%) in the maraviroc group had grade 3 or 4 adverse events compared with 24 (18%) in placebo group; p=0·072); 25 (18%) in the maraviroc group and 21 (15%) in the placebo group had serious treatment emergent adverse events (p=0·63). Maraviroc had no significant effect on development of IRIS after ART initiation. Inclusion of this CCR5 inhibitor in an initial treatment regimen does not confer a meaningful protection from the occurrence of IRIS in people with advanced HIV infection. Pfizer. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arfian, Nur; Emoto, Noriaki, E-mail: emoto@med.kobe-u.ac.jp; Department of Clinical Pharmacy, Kobe Pharmaceutical University, Kobe
Highlights: Black-Right-Pointing-Pointer Ischemia/reperfusion injury (IRI) induced increased endothelin-1 (ET-1) expression. Black-Right-Pointing-Pointer IRI was accompanied by tubular injury and remodeling of renal arteries. Black-Right-Pointing-Pointer IRI increased oxidative stress and inflammation. Black-Right-Pointing-Pointer Genetic suppression of ET-1 in endothelial cells attenuates IRI in the kidney. Black-Right-Pointing-Pointer The mechanisms include the inhibition of oxidative stress and inflammation. -- Abstract: Background: The prognosis of patients after acute kidney injury (AKI) is poor and treatment is limited. AKI is mainly caused by renal ischemia/reperfusion injury (IRI). During the extension phase of IRI, endothelial damage may participate in ischemia and inflammation. Endothelin-1 (ET-1) which is mostly secretedmore » by endothelial cells is an important actor of IRI, particularly through its strong vasoconstrictive properties. We aimed to analyze the specific role of ET-1 from the endothelial cells in AKI. Methods: We used mice lacking ET-1 in the vascular endothelial cells (VEETKO). We induced IRI in VEETKO mice and wild type controls by clamping both kidneys for 30 min. Sham operated mice were used as controls. Mice were sacrificed one day after IRI in order to investigate the extension phase of IRI. Kidney function was assessed based on serum creatinine concentration. Levels of expression of ET-1, its receptor ET{sub A}, protein kinase C, eNOS, E-Cadherin and inflammation markers were evaluated by real time PCR or western blot. Tubular injury was scored on periodic acid Schiff stained kidney preparations. Lumen and wall area of small intrarenal arteries were measured on kidney slices stained for alpha smooth muscle cell actin. Oxidative stress, macrophage infiltration and cell proliferation was evaluated on slices stained for 8-hydroxy-2 Prime -deoxyguanosine, F4/80 and PCNA, respectively. Results: IRI induced kidney failure and increased ET-1 and ET{sub A} receptor expression. This was accompanied by tubular injury, wall thickening and reduction of lumen area/wall area ratio of small renal arteries, increased oxidative stress and inflammation. These parameters were attenuated in VEETKO mice. Conclusion: Our results suggest that suppression of ET-1 from the endothelial cells attenuates IRI kidney injury. Blocking ET-1 effects may represent a therapeutic strategy in the management of AKI.« less
Tian, Weijun; Liu, Yi; Zhang, Bai; Dai, Xiangchen; Li, Guang; Li, Xiaochun; Zhang, Zhixiang; Du, Caigan; Wang, Hao
2015-02-01
Cold ischemia-reperfusion injury (IRI) is a major cause of graft failure in lung transplantation. Despite therapeutic benefits of mesenchymal stem cells (MSCs) in attenuating acute lung injury, their protection of lung transplants from cold IRI remains elusive. The present study was to test the efficacy of MSCs in the prevention of cold IRI using a novel murine model of orthotopic lung transplantation. Donor lungs from C57BL/6 mice were exposed to 6 h of cold ischemia before transplanted to syngeneic recipients. MSCs were isolated from the bone marrows of C57BL/6 mice for recipient treatment. Gas exchange was determined by the measurement of blood oxygenation, and lung injury and inflammation were assessed by histological analyses. Intravenously delivered MSC migration/trafficking to the lung grafts occurred within 4-hours post-transplantation. As compared to untreated controls, the graft arterial blood oxygenation (PaO2/FiO2) capacity was significantly improved in MSC-treated recipients as early as 4 h post-reperfusion and such improvement continued over time. By 72 h, oxygenation reached normal level that was not seen in controls. MSCs treatment conferred significant protection of the grafts from cold IRI and cell apoptosis, which is correlated with less cellular infiltration, a decrease in proinflammatory cytokines (TNF-α, IL-6) and toll-like receptor 4, and an increase in anti-inflammatory TSG-6 generation. MSCs provide significant protection against cold IRI in lung transplants, and thus may be a promising strategy to improve outcomes after lung transplantation.
NASA Astrophysics Data System (ADS)
Bello, S. A.; Abdullah, M.; Hamid, N. S. A.; Yoshikawa, A.; Olawepo, A. O.
2017-07-01
The ionospheric thickness (B0) and shape (B1) are bottomside profile parameters introduced by the International Reference Ionosphere (IRI) model. We have validated these parameters with the latest version of the IRI-2012 model and compared them with the solar quiet of geomagnetic H-component (SqH). The B0, B1 and SqH are calculated from the measurements obtained from digisonde DPS-4 sounder and the Magnetic Data Acquisition System (MAGDAS) magnetometer, respectively at Ilorin (geo latitude 8.50°N, geo longitude 4.68°E, and Magnetic dip 4.1°S) an equatorial station in the African sector. The study was for the year 2010, a year of low solar activity (with 27-day averaged solar index, F10.7 = 80 sfu). The results show that B0 for the entire months was higher during the daytime than during the night time. On the other hand, the magnitude of B1during the daytime period is lower than nighttime values and exhibit oscillatory pattern. By comparing the experimental observations of the profile parameters with the IRI-2012 model prediction, we found that B0 was fairly represented by the IRI model options during the nighttime period while discrepancies exist between the model estimates and the experimental values during the morning till midday. A close agreement exists between the observed B1 values and IRI model options. We observed a positive and significant correlation coefficient between B0 and SqH indicating a plausible relationship between these parameters while a weak and negative correlation coefficient between B1 and SqH was observed. We concluded that the difference in the relationship of SqH and the profile parameters B0 and B1 observed can be attributed to their sensitivity to the electric field which is responsible for the E × B drift which in turn modulate the height of the F2.
TAE+ 5.1 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.1 (DEC VAX ULTRIX VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. Data-driven graphical objects such as dials, thermometers, and strip charts are also included. TAE Plus updates the strip chart as the data values change. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. The Silicon Graphics version of TAE Plus now has a font caching scheme and a color caching scheme to make color allocation more efficient. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides an extremely powerful means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System, Version 11 Release 4, and the Open Software Foundation's Motif Toolkit 1.1 or 1.1.1. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus comes with InterViews and idraw, two software packages developed by Stanford University and integrated in TAE Plus. TAE Plus was developed in 1989 and version 5.1 was released in 1991. TAE Plus is currently available on media suitable for eight different machine platforms: 1) DEC VAX computers running VMS 5.3 or higher (TK50 cartridge in VAX BACKUP format), 2) DEC VAXstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 3) DEC RISC workstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 4) HP9000 Series 300/400 computers running HP-UX 8.0 (.25 inch HP-preformatted tape cartridge in UNIX tar format), 5) HP9000 Series 700 computers running HP-UX 8.05 (HP 4mm DDS DAT tape cartridge in UNIX tar format), 6) Sun3 series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), 7) Sun4 (SPARC) series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), and 8) SGI Indigo computers running IRIX 4.0.1 and IRIX/Motif 1.0.1 (.25 inch IRIS tape cartridge in UNIX tar format). An optional Motif Object Code License is available for either Sun version. TAE is a trademark of the National Aeronautics and Space Administration. X Window System is a trademark of the Massachusetts Institute of Technology. Motif is a trademark of the Open Software Foundation. DEC, VAX, VMS, TK50 and ULTRIX are trademarks of Digital Equipment Corporation. HP9000 and HP-UX are trademarks of Hewlett-Packard Co. Sun3, Sun4, SunOS, and SPARC are trademarks of Sun Microsystems, Inc. SGI and IRIS are registered trademarks of Silicon Graphics, Inc.
TAE+ 5.1 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.1 (SUN3 VERSION)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. Data-driven graphical objects such as dials, thermometers, and strip charts are also included. TAE Plus updates the strip chart as the data values change. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. The Silicon Graphics version of TAE Plus now has a font caching scheme and a color caching scheme to make color allocation more efficient. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides an extremely powerful means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System, Version 11 Release 4, and the Open Software Foundation's Motif Toolkit 1.1 or 1.1.1. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus comes with InterViews and idraw, two software packages developed by Stanford University and integrated in TAE Plus. TAE Plus was developed in 1989 and version 5.1 was released in 1991. TAE Plus is currently available on media suitable for eight different machine platforms: 1) DEC VAX computers running VMS 5.3 or higher (TK50 cartridge in VAX BACKUP format), 2) DEC VAXstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 3) DEC RISC workstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 4) HP9000 Series 300/400 computers running HP-UX 8.0 (.25 inch HP-preformatted tape cartridge in UNIX tar format), 5) HP9000 Series 700 computers running HP-UX 8.05 (HP 4mm DDS DAT tape cartridge in UNIX tar format), 6) Sun3 series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), 7) Sun4 (SPARC) series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), and 8) SGI Indigo computers running IRIX 4.0.1 and IRIX/Motif 1.0.1 (.25 inch IRIS tape cartridge in UNIX tar format). An optional Motif Object Code License is available for either Sun version. TAE is a trademark of the National Aeronautics and Space Administration. X Window System is a trademark of the Massachusetts Institute of Technology. Motif is a trademark of the Open Software Foundation. DEC, VAX, VMS, TK50 and ULTRIX are trademarks of Digital Equipment Corporation. HP9000 and HP-UX are trademarks of Hewlett-Packard Co. Sun3, Sun4, SunOS, and SPARC are trademarks of Sun Microsystems, Inc. SGI and IRIS are registered trademarks of Silicon Graphics, Inc.
TAE+ 5.1 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.1 (SUN3 VERSION WITH MOTIF)
NASA Technical Reports Server (NTRS)
TAE SUPPORT OFFICE
1994-01-01
TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. Data-driven graphical objects such as dials, thermometers, and strip charts are also included. TAE Plus updates the strip chart as the data values change. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. The Silicon Graphics version of TAE Plus now has a font caching scheme and a color caching scheme to make color allocation more efficient. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides an extremely powerful means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System, Version 11 Release 4, and the Open Software Foundation's Motif Toolkit 1.1 or 1.1.1. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus comes with InterViews and idraw, two software packages developed by Stanford University and integrated in TAE Plus. TAE Plus was developed in 1989 and version 5.1 was released in 1991. TAE Plus is currently available on media suitable for eight different machine platforms: 1) DEC VAX computers running VMS 5.3 or higher (TK50 cartridge in VAX BACKUP format), 2) DEC VAXstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 3) DEC RISC workstations running ULTRIX 4.1 or later (TK50 cartridge in UNIX tar format), 4) HP9000 Series 300/400 computers running HP-UX 8.0 (.25 inch HP-preformatted tape cartridge in UNIX tar format), 5) HP9000 Series 700 computers running HP-UX 8.05 (HP 4mm DDS DAT tape cartridge in UNIX tar format), 6) Sun3 series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), 7) Sun4 (SPARC) series computers running SunOS 4.1.1 (.25 inch tape cartridge in UNIX tar format), and 8) SGI Indigo computers running IRIX 4.0.1 and IRIX/Motif 1.0.1 (.25 inch IRIS tape cartridge in UNIX tar format). An optional Motif Object Code License is available for either Sun version. TAE is a trademark of the National Aeronautics and Space Administration. X Window System is a trademark of the Massachusetts Institute of Technology. Motif is a trademark of the Open Software Foundation. DEC, VAX, VMS, TK50 and ULTRIX are trademarks of Digital Equipment Corporation. HP9000 and HP-UX are trademarks of Hewlett-Packard Co. Sun3, Sun4, SunOS, and SPARC are trademarks of Sun Microsystems, Inc. SGI and IRIS are registered trademarks of Silicon Graphics, Inc.
Acceptance and effects of a therapeutic renal food in pet cats with chronic kidney disease
Fritsch, Dale A; Jewell, Dennis E
2015-01-01
Introduction Renal foods are used to manage chronic kidney disease (CKD) in dogs and cats, but their effectiveness may be limited by the ability to transition animals to them. Material and Methods In a prospective study, pet cats with previously undiagnosed kidney disease (20 International Renal Interest Society (IRIS) 1, 61 IRIS 2, 14 IRIS 3/4, 33 at risk for CKD) were transitioned to a renal food. Markers of renal function were measured and owners answered questionnaires about their pet over one year. Results All but eight cats (120/128; 94 per cent) successfully transitioned to the renal food. Most of the time, cats moderately or extremely liked the food (89 per cent), ate at least half (73 per cent) and were moderately or extremely enthusiastic while eating (68 per cent). Cats rarely disliked the food (2 per cent) or refused to eat it (1 per cent). Markers of renal function were unchanged in IRIS 1 and 2 cats and changed little in IRIS 3/4 cats. In all groups, owner-assessed quality of life improved initially and then remained stable. Mean bodyweight did not change in cats with CKD. Conclusions Most cats with CKD successfully transitioned to the renal food. The results also support previous studies that the renal food can help stabilise cats with CKD. PMID:26587240
Auto-cortex of crystalline lens-induced iris neovascularization
Liu, Lin; Li, Yong-Ping; Zhang, Bo; Zhang, Wen-Xin
2012-01-01
AIM To investigate auto-cortex of crystalline lens induced iris neovascularization (INV). METHODS Thirty-six eyes of 36 guinea-pigs were included and divided into three groups randomly in this cohort study. Group A: the right lens nucleus was extracted and the remaining cortical lens material was aspirated thoroughly. Group B: the lens was removed and 30µL precipitated lens cortex was injected into the anterior chamber again. Group C: aspirated the lens cortex of the left eyes and inject them into the right anterior chambers about 10µL. Clinical changes were followed by slit-lamp examination and photograph. The eye balls were enucleated at the day of 2, 4, 7, 11, 13, 17 after operation. HE was used to detect the pathological changes. RESULTS Group A: INV had not been observed until the end of empirical study. The stromal layer contained thick wall vessels, without expansion. Group B: All eyes developed INV. Postoperative (po) 7 days; the eyes developed intense and extensive INV. The vessels of iris expanded remarkably and neovascularization was observed erupting from it's lateral wall and stretching towards the anterior surface. Po11 days, INV regressed gradually after lens cortex had been absorbed. Group C: Po four (4) days, new blood vessels liking red line were presented on the anterior surface of the iris and they were not obvious. CONCLUSION Anterior chamber inside lens coriaceous can induce iris new blood vessels. PMID:22553749
Yorio, T; DeLoach, G; Satumtira, N
1985-01-01
The effects of antiglaucoma drugs on [32P]-orthophosphate incorporation into phospholipids of iris and ciliary process were investigated. Both iris and ciliary process rapidly incorporated 32Pi into the major phospholipids, with the acidic phosphoinositides demonstrating a greater labelling than phosphatidylcholine, indicating a greater turnover. The muscarinic agonists, carbachol and pilocarpine, stimulated 32Pi-labelling of phosphatidylinositol (PI) and phosphatidic acid (PA) in both iris and ciliary process. These effects were blocked by atropine, suggesting that the response was mediated through muscarinic receptors. The beta blocking ocular hypotensive drugs, propranolol, timolol and atenolol, produced varying effects on 32P incorporation into phospholipids of iris and ciliary process. Propranolol stimulated 32Pi-labelling into phosphatidylinositol 4', 5' bisphosphate (PIP2), phosphatidylinositol 4' phosphate (PIP), PI and PA. Timolol decreased 32Pi-incorporation into PIP2 and PI, whereas atenolol, a selective beta 1 antagonist, had no significant effect on 32Pi-labelling of phospholipids. The above findings on propranolol agree with previous observations which demonstrated that propranolol redirects glycerolipid metabolism through multiple effects on the enzymes in phospholipid biosynthesis, particularly in stimulating phosphatidylinositol kinases. The results with timolol suggest that this drug may decrease phosphoinositide hydrolysis. The effects of these ocular hypotensive, non-selective beta blocking drugs on phospholipid turnover may ultimately limit the accumulation of breakdown products which could serve as cellular messengers.
NASA Astrophysics Data System (ADS)
Brooks, Daniel R.; Wozniak, Kaitlin T.; Knox, Wayne; Ellis, Jonathan D.; Huxlin, Krystel R.
2018-02-01
Intra-Tissue Refractive Index Shaping (IRIS) uses a 405 nm femtosecond laser focused into the stromal region of the cornea to induce a local refractive index change through multiphoton absorption. This refractive index change can be tailored through scanning of the focal region and variations in laser power to create refractive structures, such as gradient index lenses for visual refractive correction. Previously, IRIS was used to create 2.5 mm wide, square, -1 D cylindrical refractive structures in living cats. In the present work, we first wrote 400 μm wide bars of refractive index change at varying powers in enucleated cat globes using a custom flexure-based scanning system. The cornea and surrounding sclera were then removed and mounted into a wet cell. The induced optical phase change was measured with a Mach- Zehnder Interferometer (MZI), and appeared as fringe displacement, whose magnitude was proportional to the refractive index change. The interferograms produced by the MZI were analyzed with a Fourier Transform based algorithm in order to extract the phase change. This provided a phase change versus laser power calibration, which was then used to design the scanning and laser power distribution required to create -1.5 D cylindrical Fresnel lenses in cat cornea covering an area 6 mm in diameter. This prescription was inscribed into the corneas of one eye each of two living cats, under surgical anesthesia. It was then verified in vivo by contrasting wavefront aberration measurements collected pre- IRIS with those obtained over six months post-IRIS using a Shack-Hartmann wavefront sensor.
Iris registration in wavefront-guided LASIK to correct mixed astigmatism.
Khalifa, Mounir; El-Kateb, Mohamed; Shaheen, Mohamed Shafik
2009-03-01
To investigate the predictability, safety, and efficiency of wavefront-guided laser in situ keratomileusis (LASIK) with iris-registration technology to correct mixed astigmatism. Vision correction center, Alexandria, Egypt. This retrospective double-blind study included randomly selected patients with mixed astigmatism who sought laser refractive surgery. Patients were divided equally into 3 groups and treated with conventional LASIK and manual marking, wavefront-guided LASIK and manual marking, or wavefront-guided LASIK with iris registration (LASIK+IR group). Eyes were analyzed preoperatively and up to 3 months postoperatively. The LASIK+IR group had better postoperative uncorrected visual acuity (100% 20/30 or better; 90% 20/20 or better; 20% 20/16 or better) than the other groups and did not lose preoperative best spectacle-corrected visual acuity, unlike the other groups. This group also had the highest percentage of eyes that gained lines of acuity (20% 1 line; 10% 2 lines). The LASIK+IR group had the highest predictability of spherical refraction (80% within +/-0.50 diopter [D]; 100% within +/-1.00 D [P<.05] and the highest predictability of cylinder refraction. The LASIK+IR eyes had a significantly smaller increase postoperatively in coma, trefoil, and secondary astigmatism. There was no significant difference between groups in spherical aberration or quadrafoil. The LASIK-IR group had the most improvement in scotopic contrast sensitivity (P<.05). Wavefront-guided LASIK with iris registration was more predictable, safe, and efficient than conventional or wavefront-guided LASIK with manual marking in correcting mixed astigmatism. Further studies are needed to confirm these results.
Abdel-Latif, A A; Ding, K H; Akhtar, R A; Yousufzai, S Y
1996-09-01
In both immortalized cat iris sphincter smooth muscle cells (SV-CISM-2 cells) and cat iris sphincter, endothelin-1 (ET-1) markedly increased the activities of phospholipase A2 (PLA2), as measured by the release of arachidonic acid (AA), phospholipase C (PLC), as measured by the production of inositol trisphosphate (IP3), and phospholipase D (PLD), as measured by the formation of phosphatidylethanol (PEt). In SV-CISM-2 cells, ET-1 induced AA release, IP3 production and PEt formation in a dose- and time-dependent manner. The dose-response studies showed that the peptide is more potent in activating PLD (EC50 = 1.2 nM) than in activating PLC (EC50 = 1.5 nM) or PLA2 (EC50 = 1.7 nM). The time course studies revealed that ET-1 activated the phospholipases in a temporal sequence in which PLA2 was stimulated first (t1/2 = 12 s), followed by PLC (t1/2 = 48 s) and lastly PLD (t1/2 = 106 s). In SV-CISM-2 cells, in contrast to the intact iris sphincter, sarafotoxin-c, an ETB receptor agonist, had no effect on the phospholipases, and indomethacin, a cyclooxygenase inhibitor, had no effect on the stimulatory effect of ET-1 on the phospholipases. These results suggest that in this smooth muscle cell line, ET-1 interacts with the ETA receptor subtype to activate, via G proteins, phospholipases A2, C and D in a temporal sequence.
IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR TETRACHLOROETHYLENE
The known toxic effects of perchloroethylene will be summarized, with citations from current scientific literature. The critical effects will be identified, and from this the RfD and RfC and cancer unit risk factors will be derived. The RfD and RfC are reference doses and air c...
Wang, Bing-hong; Yao, Yu-feng
2012-01-01
Objective: To evaluate the prevalence of primary iris and/or ciliary body cysts in eyes with shallow anterior chamber and their effect on the narrowing of the anterior chamber angle. Methods: Among the general physical check-up population, subjects with shallow anterior chambers, as judged by van Herick technique, were recruited for further investigation. Ultrasound biomicroscope (UBM) was used to detect and measure the cysts located in the iris and/or ciliary body, the anterior chamber depth (ACD), the angle opening distance at 500 μm (AOD500), and the trabecular-iris angle (TIA). A-scan ultrasonography was used to measure the ocular biometry, including lens thickness, axial length, lens/axial length factor (LAF), and relative lens position (RLP). The effect of the cyst on narrowing the corresponding anterior chamber angle and the entire angle was evaluated by the UBM images, ocular biometry, and gonioscopic grading. The eye with unilateral cyst was compared with the eye without the cyst for further analysis. Results: Among the 727 subjects with shallow anterior chamber, primary iris and ciliary body cysts were detected in 250 (34.4%) patients; among them 96 (38.4%) patients showed unilateral single cyst, 21 (8.4%) patients had unilateral double cysts, and 42 (16.8%) patients manifested unilateral multiple and multi-quadrants cysts. Plateau iris configuration was found in 140 of 361 (38.8%) eyes with cysts. The mean size of total cysts was (0.6547±0.2319) mm. In evaluation of the effect of the cyst size and location on narrowing the corresponding angle to their position, the proportion of the cysts causing corresponding angle narrowing or closure among the cysts larger than 0.8 mm (113/121, 93.4%) was found to be significantly higher than that of the cysts smaller than 0.8 mm (373/801, 46.6%), and a significant higher proportion was also found in the cysts located at iridociliary sulcus (354/437, 81.0%) than in that at the pars plicata (131/484, 27.1%). In evaluating the effect of the cyst on the entire anterior chamber angle, the eyes with multiple and multi-quadrants cysts manifested significant narrowing of the entire anterior chamber angle as compared with the eyes without cysts, based on the data analysis in comparison of TIA, AOD500, and gonioscopic grading evaluation. The unilateral single or double cysts in the eyes had no significant effect on narrowing of anterior chamber angle as compared with eyes without cysts. The iris and/or ciliary body cysts did not seem to affect the axial length, ACD, lens thickness, RLP, LAF. Conclusions: The prevalence of primary iris and ciliary body cyst was 34.4% in the subjects with shallow anterior chamber. The cysts larger than 0.8 mm, locating at iridociliary sulcus, or multiple and extensive cysts were inclined to cause the angle narrowing or closure. PMID:22949363
SIMULTANEOUS IRIS AND HINODE/EIS OBSERVATIONS AND MODELING OF THE 2014 OCTOBER 27 X2.0 CLASS FLARE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polito, V.; Reep, J. W.; Del Zanna, G.
We present a study of the X2-class flare which occurred on 2014 October 27 and was observed with the Interface Region Imaging Spectrograph (IRIS) and the EUV Imaging Spectrometer (EIS) on board the Hinode satellite. Thanks to the high cadence and spatial resolution of the IRIS and EIS instruments, we are able to compare simultaneous observations of the Fe xxi 1354.08 Å and Fe xxiii 263.77 Å high-temperature emission (≳10 MK) in the flare ribbon during the chromospheric evaporation phase. We find that IRIS observes completely blueshifted Fe xxi line profiles, up to 200 km s{sup −1} during the rise phase of the flare, indicatingmore » that the site of the plasma upflows is resolved by IRIS. In contrast, the Fe xxiii line is often asymmetric, which we interpret as being due to the lower spatial resolution of EIS. Temperature estimates from SDO/AIA and Hinode/XRT show that hot emission (log(T[K]) > 7.2) is first concentrated at the footpoints before filling the loops. Density-sensitive lines from IRIS and EIS give estimates of electron number density of ≳10{sup 12} cm{sup −3} in the transition region lines and 10{sup 10} cm{sup −3} in the coronal lines during the impulsive phase. In order to compare the observational results against theoretical predictions, we have run a simulation of a flare loop undergoing heating using the HYDRAD 1D hydro code. We find that the simulated plasma parameters are close to the observed values that are obtained with IRIS, Hinode, and AIA. These results support an electron beam heating model rather than a purely thermal conduction model as the driving mechanism for this flare.« less
Steinwender, Gernot; Shajari, Mehdi; Kohnen, Thomas
2018-05-01
To report the efficacy, predictability, and safety of femtosecond laser-assisted cataract surgery (FLACS) in eyes with anterior chamber phakic intraocular lenses (IOLs). This retrospective case series included eyes with previous implantation of an angle-supported and an iris-fixated phakic IOL for the correction of myopia that underwent a combined procedure of phakic IOL ex-plantation and FLACS with in-the-bag implantation of a posterior chamber IOL. Postoperative corrected distance visual acuity (CDVA), predictability of refractive outcome, and occurrence of intraoperative and postoperative complications were analyzed. Ten eyes of 7 patients with significant cataract were included: 5 eyes with an angle-supported foldable hydrophobic phakic IOL, 4 eyes with an angle-supported polymethylmethacrylate (PMMA) phakic IOL, and 1 eye with an iris-fixated PMMA phakic IOL. Mean follow-up after FLACS was 8.4 ± 5.8 months. Mean interval between phakic IOL implantation and FLACS was 11.9 ± 4.0 years. After the combined procedure of phakic IOL explantation and FLACS, mean manifest refractive spherical equivalent (MRSE) was -0.11 ± 0.49 diopters (D) and MRSE was within ± 0.75 D of target refraction in all eyes. Four eyes received a toric posterior chamber IOL after phacoemulsification. Mean preoperative CDVA of 0.40 ± 0.23 logMAR improved significantly to 0.22 ± 0.11 logMAR postoperatively (P = .027). No intraoperative or postoperative complications occurred. The results in this series showed that FLACS in eyes with previous implantation of both rigid and foldable anterior chamber phakic IOLs offers good refractive outcomes with a high level of predictability and safety. [J Refract Surg. 2018;34(5):338-342.]. Copyright 2018, SLACK Incorporated.
Improving File System Performance by Striping
NASA Technical Reports Server (NTRS)
Lam, Terance L.; Kutler, Paul (Technical Monitor)
1998-01-01
This document discusses the performance and advantages of striped file systems on the SGI AD workstations. Performance of several striped file system configurations are compared and guidelines for optimal striping are recommended.
2008-03-01
80 5. Time Frame of the Experiment...81 6. Eyeglasses ............................................................................................81 D. OBSERVED RESULTS...97 2. Eyeglasses are a Factor
Zielińska-Bliźniewska, Hanna; Sułkowski, Wiesław J; Pietkiewicz, Piotr; Miłoński, Jarosław; Mazurek, Agnieszka; Olszewski, Jurek
2012-06-01
The aim of this study was to compare the parameters of vocal acoustic and vocal efficiency analyses in medical students and academic teachers with use of the IRIS and DiagnoScope Specialist software and to evaluate their usefulness in prevention and certification of occupational disease. The study group comprised 40 women, including students and employees of the Military Medical Faculty, Medical University of Łodź. After informed consent had been obtained from the participant women, the primary medical history was taken, videolaryngoscopic and stroboscopic examinations were performed and diagnostic vocal acoustic analysis was carried out with the use of the IRIS and Diagno-Scope Specialist software. Based on the results of the performed measurements, the statistical analysis evidenced the compatibility between two software programs, IRIS and DiagnoScope Specialist, with the only exception of the F4 formant. The mean values of vocal acoustic parameters in medical students and academic teachers, obtained by means of the IRIS software, can be used as standards for the female population not yet developed by the producer. When using the DiagnoScope Specialist software, some mean values were higher and some lower than the standards specified by the producer. The study evidenced the compatibility between two measurement software programs, IRIS and DiagnoScope Specialist, except for the F4 formant. It should be noted that the later has advantage over the former since the standard values of vocal acoustic parameters have been worked out by the producer. Moreover, they only slightly departed from the values obtained in our study and may be useful in diagnostics of occupational voice disorders.
Advanced Methods for Aircraft Engine Thrust and Noise Benefits: Nozzle-Inlet Flow Analysis
NASA Technical Reports Server (NTRS)
Gilinsky, Mikhail; Morgan, Morris H.; Povitsky, Alex; Schkolnikov, Natalia; Njoroge, Norman; Coston, Calvin; Blankson, Isaiah M.
2001-01-01
The Fluid Mechanics and Acoustics Laboratory at Hampton University (HU/FM&AL) jointly with the NASA Glenn Research Center has conducted four connected subprojects under the reporting project. Basically, the HU/FM&AL Team has been involved in joint research with the purpose of theoretical explanation of experimental facts and creation of accurate numerical simulation techniques and prediction theory for solution of current problems in propulsion systems of interest to the NAVY and NASA agencies. This work is also supported by joint research between the NASA GRC and the Institute of Mechanics at Moscow State University (IM/MSU) in Russia under a CRDF grant. The research is focused on a wide regime of problems in the propulsion field as well as in experimental testing and theoretical and numerical simulation analyses for advanced aircraft and rocket engines. The FM&AL Team uses analytical methods, numerical simulations and possible experimental tests at the Hampton University campus. The fundamental idea uniting these subprojects is to use nontraditional 3D corrugated and composite nozzle and inlet designs and additional methods for exhaust jet noise reduction without essential thrust loss and even with thrust augmentation. These subprojects are: (1) Aeroperformance and acoustics of Bluebell-shaped and Telescope-shaped designs; (2) An analysis of sharp-edged nozzle exit designs for effective fuel injection into the flow stream in air-breathing engines: triangular-round, diamond-round and other nozzles; (3) Measurement technique improvement for the HU Low Speed Wind Tunnel; a new course in the field of aerodynamics, teaching and training of HU students; experimental tests of Mobius-shaped screws: research and training; (4) Supersonic inlet shape optimization. The main outcomes during this reporting period are: (l) Publications: The AIAA Paper #00-3170 was presented at the 36th AIAA/ASME/SAE/ASEE Joint Propulsion Conference, 17-19 June, 2000, Huntsville, AL. The AIAA Paper #01-1893 has been accepted for the AIAA/NAL-NASDA-ISAS 10th International Space Planes and Hypersonic Systems and Technologies Conference, 24-27 April 2001, Kyoto, Japan. The AIAA Paper #01 -3204 has been accepted for presentation at the 37th AIAA/ASME/SAE/ASEE Joint Propulsion Conference, being held on 08-11 July, in Salt Lake City, UT; (2) A U.S. patent #6,082,635 was granted on July 4, 2000; (3) Grants and proposals: The H U/ FM&AL was awarded the NASA grant NAG-3-2495 in October 2000 and the laboratory is a primary U.S. research team in a joint project under the CRDF award granted to the NASA GRC and IM/MSU (Russia) in July 2000; (4) Theory and numerical simulations: Analytical theory, numerical simulation, comparison of theoretical with experimental results, and modification of theoretical approaches, models, grids, etc., have been conducted for several complicated 2D and 3D nozzle and inlet designs using NASA, ICASE, and IM/MSU codes based on full Euler and Navier-Stokes solvers: CFL3D, FLUENT, and GODUNOV, and others; (5) Experimental Tests: (a) A new course: "Advanced Aerodynamics and Aircraft Performance" presented in spring semester, 2001; training and experimental test research using the HU LSWT. (b) Small-scale M6bius-shaped screws were tested in different conditions and their application has shown essential benefits by comparison with traditional designs; (6) Installation in the FM&AL computer system: second software TECPLOT 8.0 for the UNIX SGI workstation and free TECPLOT 7.5 for the PC Dell computer, and 2D and 3D GRIDGEN (version 9) for the UNIX SGI as well as installation of two free NASA codes, 3D MAG and VULCAN; (7) Student Research Activity: Involvement of two undergraduate students as research assistants in the current research project.
NASA Technical Reports Server (NTRS)
Short, David A.
2000-01-01
This report presents the Applied Meteorology Unit's (AMU) evaluation of SIGMET Inc.'s Integrated Radar Information System (IRIS) Product Generator and recommendations for products emphasizing lightning and microburst tools. The IRIS Product Generator processes radar reflectivity data from the Weather Surveillance Radar, model 74C (WSR-74C), located on Patrick Air Force Base. The IRIS System was upgraded from version 6.12 to version 7.05 in late December 1999. A statistical analysis of atmospheric temperature variability over the Cape Canaveral Air Force Station (CCAFS) Weather Station provided guidance for the configuration of radar products that provide information on the mixed-phase (liquid and ice) region of clouds, between 0 C and -20 C. Mixed-phase processes at these temperatures are physically linked to electrification and the genesis of severe weather within convectively generated clouds. Day-to-day variations in the atmospheric temperature profile are of sufficient magnitude to warrant periodic reconfiguration of radar products intended for the interpretation of lightning and microburst potential of convectively generated clouds. The AMU also examined the radar volume-scan strategy to determine the scales of vertical gaps within the altitude range of the 0 C to -20 C isotherms over the Kennedy Space Center (KSC)/CCAFS area. This report present's two objective strategies for designing volume scans and proposes a modified scan strategy that reduces the average vertical gap by 37% as a means for improving radar observations of cloud characteristics in the critical 0 C to -20 C layer. The AMU recommends a total of 18 products, including 11 products that require use of the IRIS programming language and the IRIS User Product Insert feature. Included is a cell trends product and display, modeled after the WSR-88D cell trends display in use by the National Weather Service.
ERIC Educational Resources Information Center
Paris, Scott G.; Carpenter, Robert D.
2003-01-01
Provides information about informal reading inventories (IRI), an early reading assessment. Explains what IRIs are; who should administer an IRI; when and how to administer an IRI; the reliability of data from IRIs; and the limitations of IRIs. (PM)
Forlini, Cesare; Forlini, Matteo; Rejdak, Robert; Prokopiuk, Agata; Levkina, Oxana; Bratu, Adriana; Rossini, Paolo; Cagampang, Perfecto R; Cavallini, Gian Maria
2013-03-01
Combined post-traumatic aniridia and aphakia demand extensive and complex reconstructive surgery. We present our approach for simultaneous correction of this surgical situation with the use of the ArtificialIris (Dr. Schmidt Intraocularlinsen GmbH, Germany) with a foldable acrylic IOL Lentis L-313 (Oculentis, GmbH, Germany) sutured to its surface. The novelty (our first operation was on June 2010) of this surgical technique is based on the combined use of foldable (with closed haptics) IOL and Artificialiris to correct post-traumatic aniridia and aphakia. Four consecutive cases of combined post-traumatic lesions of iris and lens, corrected with complex device ArtificialIris and foldable IOL. In two cases, the compound implant was sutured to the sclera in sulcus during the penetrating keratoplasty; in another case, it was positioned through a corneal incision of about 5.0 mm with transscleral fixation, and in one patient with preserved capsular support and possibility of IOL in-the-bag implantation the ArtificialIris was placed in sulcus sutureless through a clear corneal tunnel. Maximal follow-up was 6 months. The complex device was placed firmly fixed within the sulcus, including in the eye implanted without sutures, and showed a stable and centered position without any tilt or torque. Management of post-traumatic aniridia combined with aphakia by haptic fixation of a foldable acrylic IOL on a foldable iris prosthesis appears to be a promising approach which gives the surgeon the possibility to correct a complex lesion with one procedure, which is less traumatic and faster. Existence of foldable materials, both iris and IOL, permits relatively small corneal incisions (4.0-5.0 mm). Moreover, the custom-tailored iris prosthesis gives a perfect aesthetic result.
Shields, Carol L; Nickerson, Stephanie J; Al-Dahmash, Saad; Shields, Jerry A
2013-09-01
Waardenburg syndrome typically manifests with congenital iris pigmentary abnormalities, but careful inspection can reveal additional posterior uveal pigmentary abnormalities. To demonstrate iris and choroidal hypopigmentation in patients with Waardenburg syndrome. Retrospective review of 7 patients referred for evaluation of presumed ocular melanocytosis. To describe the clinical and imaging features of the anterior and posterior uvea. In all patients, the diagnosis of Waardenburg syndrome was established. The nonocular features included white forelock in 4 of 7 (57%), tubular nose in 5 of 6 (83%), and small nasal alae in 5 of 6 (83%) patients. In 2 patients, a hearing deficit was documented on audiology testing. Family history of Waardenburg syndrome was elicited in 5 of 7 (71%) patients. Ocular features (7 patients) included telecanthus in 5 (71%), synophrys in 2 (29%), iris hypopigmentation in 5 (71%), and choroidal hypopigmentation in 5 (71%) patients. No patient had muscle contractures or Hirschsprung disease. Visual acuity was 20/20 to 20/50 in all patients. Iris hypopigmentation in 8 eyes was sector in 6 (75%) and diffuse (complete) in 2 (25%). Choroidal hypopigmentation in 9 eyes (100%) showed a sector pattern in 6 (67%) and a diffuse pattern in 3 (33%). Anterior segment optical coherence tomography revealed the hypopigmented iris to be thinner and with shallower crypts than the normal iris. Posterior segment optical coherence tomography showed a normal retina in all patients, but the subfoveal choroid in the hypopigmented region was slightly thinner (mean, 197 μm) compared with the opposite normal choroid (243 μm). Fundus autofluorescence demonstrated mild hyperautofluorescence (scleral unmasking) in hypopigmented choroid and no lipofuscin abnormality. Waardenburg syndrome manifests hypopigmentation of the iris and choroid with imaging features showing a slight reduction in the thickness of the affected tissue.
Iris Image Classification Based on Hierarchical Visual Codebook.
Zhenan Sun; Hui Zhang; Tieniu Tan; Jianyu Wang
2014-06-01
Iris recognition as a reliable method for personal identification has been well-studied with the objective to assign the class label of each iris image to a unique subject. In contrast, iris image classification aims to classify an iris image to an application specific category, e.g., iris liveness detection (classification of genuine and fake iris images), race classification (e.g., classification of iris images of Asian and non-Asian subjects), coarse-to-fine iris identification (classification of all iris images in the central database into multiple categories). This paper proposes a general framework for iris image classification based on texture analysis. A novel texture pattern representation method called Hierarchical Visual Codebook (HVC) is proposed to encode the texture primitives of iris images. The proposed HVC method is an integration of two existing Bag-of-Words models, namely Vocabulary Tree (VT), and Locality-constrained Linear Coding (LLC). The HVC adopts a coarse-to-fine visual coding strategy and takes advantages of both VT and LLC for accurate and sparse representation of iris texture. Extensive experimental results demonstrate that the proposed iris image classification method achieves state-of-the-art performance for iris liveness detection, race classification, and coarse-to-fine iris identification. A comprehensive fake iris image database simulating four types of iris spoof attacks is developed as the benchmark for research of iris liveness detection.
Giacoia-Gripp, Carmem Beatriz Wagner; Sales, Anna Maria; Nery, José Augusto da Costa; Santos-Oliveira, Joanna Reis; de Oliveira, Ariane Leite; Sarno, Euzenir Nunes; Morgado, Mariza Gonçalves
2011-01-01
Background It is now evident that HAART-associated immunological improvement often leads to a variety of new clinical manifestations, collectively termed immune reconstitution inflammatory syndrome, or IRIS. This phenomenon has already been described in cases of HIV coinfection with Mycobacterium leprae, most of them belonging to the tuberculoid spectrum of leprosy disease, as observed in leprosy reversal reaction (RR). However, the events related to the pathogenesis of this association need to be clarified. This study investigated the immunological profile of HIV/leprosy patients, with special attention to the cellular activation status, to better understand the mechanisms related to IRIS/RR immunopathogenesis, identifying any potential biomarkers for IRIS/RR intercurrence. Methods/Principal Findings Eighty-five individuals were assessed in this study: HIV/leprosy and HIV-monoinfected patients, grouped according to HIV-viral load levels, leprosy patients without HIV coinfection, and healthy controls. Phenotypes were evaluated by flow cytometry for T cell subsets and immune differentiation/activation markers. As expected, absolute counts of the CD4+ and CD8+ T cells from the HIV-infected individuals changed in relation to those of the leprosy patients and controls. However, there were no significant differences among the groups, whether in the expression of cellular differentiation phenotypes or cellular activation, as reflected by the expression of CD38 and HLA-DR. Six HIV/leprosy patients identified as IRIS/RR were analyzed during IRIS/RR episodes and after prednisone treatment. These patients presented high cellular activation levels regarding the expression of CD38 in CD8+ cells T during IRIS/RR (median: 77,15%), dropping significantly (p<0,05) during post-IRIS/RR moments (median: 29,7%). Furthermore, an increase of cellular activation seems to occur prior to IRIS/RR. Conclusion/Significance These data suggest CD38 expression in CD8+ T cells interesting tool identifying HIV/leprosy individuals at risk for IRIS/RR. So, a comparative investigation to leprosy patients at RR should be conducted. PMID:22205964
Giacoia-Gripp, Carmem Beatriz Wagner; Sales, Anna Maria; Nery, José Augusto da Costa; Santos-Oliveira, Joanna Reis; de Oliveira, Ariane Leite; Sarno, Euzenir Nunes; Morgado, Mariza Gonçalves
2011-01-01
It is now evident that HAART-associated immunological improvement often leads to a variety of new clinical manifestations, collectively termed immune reconstitution inflammatory syndrome, or IRIS. This phenomenon has already been described in cases of HIV coinfection with Mycobacterium leprae, most of them belonging to the tuberculoid spectrum of leprosy disease, as observed in leprosy reversal reaction (RR). However, the events related to the pathogenesis of this association need to be clarified. This study investigated the immunological profile of HIV/leprosy patients, with special attention to the cellular activation status, to better understand the mechanisms related to IRIS/RR immunopathogenesis, identifying any potential biomarkers for IRIS/RR intercurrence. Eighty-five individuals were assessed in this study: HIV/leprosy and HIV-monoinfected patients, grouped according to HIV-viral load levels, leprosy patients without HIV coinfection, and healthy controls. Phenotypes were evaluated by flow cytometry for T cell subsets and immune differentiation/activation markers. As expected, absolute counts of the CD4+ and CD8+ T cells from the HIV-infected individuals changed in relation to those of the leprosy patients and controls. However, there were no significant differences among the groups, whether in the expression of cellular differentiation phenotypes or cellular activation, as reflected by the expression of CD38 and HLA-DR. Six HIV/leprosy patients identified as IRIS/RR were analyzed during IRIS/RR episodes and after prednisone treatment. These patients presented high cellular activation levels regarding the expression of CD38 in CD8+ cells T during IRIS/RR (median: 77,15%), dropping significantly (p<0,05) during post-IRIS/RR moments (median: 29,7%). Furthermore, an increase of cellular activation seems to occur prior to IRIS/RR. These data suggest CD38 expression in CD8+ T cells interesting tool identifying HIV/leprosy individuals at risk for IRIS/RR. So, a comparative investigation to leprosy patients at RR should be conducted.
NASA Astrophysics Data System (ADS)
Sinelnikov, V. M.; Lvova, G. P.; Guliaeva, T. L.; Pakhomov, S. V.; Glotov, A. P.
The possibility of measuring the electron density profile in the height interval 70-110 km with a two-frequency coherent transmitter set mounted on a 'small' geophysical rocket of type M-100 is investigated. Results are presented of measurements using the phase Doppler method carried out at middle latitudes in May 1979 and February 1980. Good consistency of the profiles measured for the D and E regions of the ionosphere with those of IRI is not always obtained, even when the correct helio and geophysic conditions of the experiments are given for calculations with IRI.
Management of dislocated intraocular lenses with iris suture.
Faria, Mun Y; Ferreira, Nuno P; Canastro, Mario
2017-01-19
Subluxated or malpositioned intraocular lenses (IOLs) and inadequate capsular support is a challenge for every ophthalmic surgeon. Iris suture of an IOL seems to be an easy technique for the management of dislocated 3-piece IOL, allowing the IOL to be placed behind the iris, far from the trabecular meshwork and corneal endothelium. The purpose of this study is to assess the results of pars plana vitrectomy (PPV) and iris suture of dislocated 3-piece acrylic IOLs. In this retrospective, nonrandomized, interventional case consecutive study, of a total of 103 dislocated IOLs, 36 eyes were considered for analysis. All 36 eyes had subluxated or totally luxated 3-piece IOL and underwent iris suture at the Ophthalmology Department of Santa Maria Hospital-North Lisbon Hospital Center, Portugal, from January 2011 until November 2015. All patients underwent 3-port 23-G PPV. The optic zone of the dislocated IOL was placed anterior to the iris with the haptics behind, in the posterior chamber. Haptics were sutured to iris followed by placement of the optics behind iris plane. Postoperative measures included best-corrected visual acuity (BCVA), IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and development of macular edema. A total of 36 eyes of 36 patients were included. All underwent successful iris fixation of dislocated 3-piece IOL. Mean overall follow-up was 15.9 months (range 3-58 months). At presentation, 16 eyes (44.4%) had a luxated IOL and 20 eyes (55.6%) a subluxated IOL. As underlying cause, 17 eyes (47.2%) had a history of complicated cataract surgery, 5 eyes (13.9%) had a traumatic dislocation of the IOL, and 6 eyes (16.7%) had a previous vitreoretinal surgery. A total of 8 eyes (22.2%) had late spontaneous IOL dislocation after uneventful cataract surgery. The mean preoperative BCVA was 1.09 ± 0.70 logarithm of the minimal angle of resolution (logMAR) units and mean postoperative BCVA was 0.48 ± 0.58 of logMAR units. The mean visual acuity improvement was 4.08 ± 5.33 lines on the logMAR scale. In this study, every IOL was stable at the last follow-up. As late complications, macular edema occurred in 1 patient and retinal detachment occurred in 2 patients. There were no cases of endophthalmitis. Iris suture fixation of subluxated IOL is a good treatment option for eyes with dislocated IOLs, leading to long-term stability of the IOL. The advantage of this procedure is using the same IOL in a closed eye surgery. No astigmatic difference is expected as no large corneal incision is needed.
Lithospheric Structure and Dynamics: Insights Facilitated by the IRIS/PASSCAL Facility
NASA Astrophysics Data System (ADS)
Meltzer, A.
2002-12-01
Through the development of community-based facilities in portable array seismology, a wide-range of seismic methods are now standard tools for imaging the Earth's interior, extending geologic observations made at the surface to depth. The IRIS/PASSCAL program provides the seismological community with the ability to routinely field experimental programs, from high-resolution seismic reflection profiling of the near surface to lithospheric scale imaging with both active and passive source arrays, to understand the tectonic evolution of continents, how they are assembled, disassembled, and modified through time. As our ability to record and process large volumes of data has improved we have moved from simple 1-D velocity models and 2-D structural cross sections of the subsurface to 3-D and 4-D images to correlate complex surface tectonics to processes in the Earth's interior. Data from individual IRIS/PASSCAL experiments has fostered multidisciplinary studies, bringing together geologists, geochemists, and geophysicists to work together on common problems. As data is collected from a variety of tectonic environments around the globe common elements begin to emerge. We now recognize and study the inherent lateral and vertical heterogeneity in the crust and mantle lithosphere and its role in controlling deformation, the importance of low velocity mobile mantle in supporting topography, and the importance of fluids and fluid migration in magmatic and deformational processes. We can image and map faults, fault zones, and fault networks to study them as systems rather than isolated planes of deformation to better understand earthquake nucleation, rupture, and propagation. An additional benefit of these community-based facilities is the pooling of resources to develop effective and sustainable education and outreach programs. These programs attract new students to pursue careers in earth science, engage the general public in the scientific enterprise, raise the profile of the earth sciences, and reveal the importance of earth processes in shaping the environment in which we live. Future challenges facing our community include continued evolution of existing facilities to keep pace with scientific inquiry, routinely utilizing fully 3-D and where appropriate 4-D data sets to understand earth structure and dynamics, and the manipulation, and analysis of large multidisciplinary data sets. Community models should be considered as a mechanism to integrate, analyze, and share data and results within a process oriented framework. Exciting developments on the horizon include EarthScope. To maximize the potential for significant advances in our understanding of tectonic processes, observations from new EarthScope facilities must be integrated with additional geologic data sets of similar quality and resolution. New real-time data streams combined with new data integration, analysis, and visualization tools will provide us with the ability to integrate data across a continuous range of spatial scales providing a new and coherent view of lithospheric dynamics from local to plate scale.
Wang, Jiamian; Song, Jie; Wang, Xiuyun; Wu, Shuo; Zhao, Yanqiu; Luo, Pinchen; Meng, Changgong
2016-12-01
A label-free ratiometric fluorescence aptasensor has been developed for the rapid and sensitive detection of cocaine in complex biofluids. The fluorescent aptasensor is composed of a non-labeled GC-38 cocaine aptamer which serves as a basic sensing unit and two fluorophores, 2-amino-5,6,7-trimethyl-1,8-naphthyridine (ATMND) and SYBR Green I (SGI) which serves as a signal reporter and a build-in reference, respectively. The detection principle is based on a specific cocaine mediated ATMND displacement reaction and the corresponding change in the fluorescence ratio of ATMND to SGI. Due to the high affinity of the non-labeled aptamer, the good precision originated from the ratiometric method, and the good fluorescence quantum yield of the fluorophore, the aptasensor shows good analytical performance with respect to cocaine detection. Under optimal conditions, the aptasensor shows a linear range of 0.10-10μM and a low limit of detection of 56nM, with a fast response of 20s. The low limit of detection is comparable to most of the fluorescent aptasensors with signal amplification strategies and much lower than all of the unamplified cocaine aptasensors. Practical sample analysis in a series of complex biofluids, including urine, saliva and serum, also indicates the good precision, stability, and high sensitivity of the aptasensor, which may have great potential for the point-of-care screening of cocaine in complex biofluids. Copyright © 2016 Elsevier B.V. All rights reserved.
Spontaneous anterior chamber hemorrhage from the iris: a unique cinematographic documentation.
Welch, R B
1980-01-01
A 54-year-old white female was observed with an apparent spontaneous idiopathic anterior chamber hemorrhage from the pupillary border of the iris. This event was documented by cinematography. A review of the literature concerning anterior chamber hemorrhage is presented and reports of spontaneous hyphema enumerated. The relationship of the entity of pupillary vascular tufts to the present report are discussed and etiologic factors considered. It is apparent that closer scrutiny of the pupillary border should be performed and iris angiography obtained in a variety of eyes to delineate normal and abnormal variants. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 PMID:6167051
Papaconstantinou, Dimitris; Kalantzis, George; Brouzas, Dimitris; Kontaxakis, Anastasios; Koutsandrea, Chryssanthi; Diagourtas, Andreas; Georgalas, Ilias
2016-01-01
The aim of this study was to compare the results of phacoemulsification through a small pupil using minimal iris manipulation versus phacoemulsification through a well-dilated pupil. This prospective randomized control (comparative) study comprised 78 patients (group I) with a maximally dilated pupil size of ≤4.00 mm and 45 patients (group II) with dilated pupil size of ≥7.00 mm. In group I patients, only viscodilation and minimal push-and-pull iris stretching with two collar-button iris-retractor hooks were utilized without iris manipulation. Phacoemulsification was performed by two senior surgeons and the technique used consisted of either stop and chop or quick chop, infusion/aspiration of lens cortex, capsular bag refill with ocular viscoelastic devices, and implantation of an acrylic foldable intraocular lens. Patients were examined on the first day and 1 month postoperatively. Forty-six eyes of group I patients had pseudoexfoliation syndrome, eleven eyes had previous glaucoma surgery, 14 eyes had angle-closure or open-angle glaucoma, and seven eyes had posterior synechiae with iritis. In group I patients, the mean pupil size measured under an operating microscope was 3.2 mm preoperatively, 4.3 mm after viscoelastic and mechanical pupil dilation, and 4.1 mm at the end of a surgical procedure. Rupture of the zonular fibers occurred in six patients of group I and the intraocular lens was implanted in the sulcus. Small iris-sphincter rupture and small hemorrhages occurred in four eyes during pupillary manipulation, but they were not evident at the end of the surgery. In group II patients, no intraoperative complications occurred. Signs of significant corneal edema and iritis were observed more frequently in group I eyes (26 eyes and 20 eyes, respectively) on the first postoperative day in comparison with group II eyes (ten eyes and six eyes, respectively). Intraocular pressure was <20 mmHg in all eyes of both groups. One month postoperatively, the pupil was round and reactive to light, the anterior chamber was quiet, and the cornea was clear in all eyes. The best-corrected visual acuity on Snellen chart was 20/40 (Monoyer's scale) or better in both groups. Phacoemulsification through a small pupil using minimal iris manipulation can be safe and exhibits the same results as those obtained with phacoemulsification through normal pupils.
IRIS : A reaction spectroscopy facility with solid H2 /D2 target
NASA Astrophysics Data System (ADS)
Holl, Matthias; Kanungo, Ritu; Alcorta, Martin; Andreoiu, Corina; Bidaman, Harris; Burbadge, Christina; Burke, Devin; Chen, Alan; Davids, Barry; Diaz Varela, Alejandra; Garrett, Paul; Hackman, Greg; Ishimoto, Shigeru; Kaur, Satbir; Keefe, Matthew; Kruecken, Reiner; Mansour, Iymad; Randhawa, Jaspreet; Sanetullaev, Alisher; Shotter, Alan; Smith, Jenna; Tanaka, Junki; Tanihata, Isao; Turko, Joseph; Workman, Orry
2016-09-01
The charged particle reaction spectroscopy station IRIS at TRIUMF is designed to allow studies of inelastic scattering and transfer reactions for low intensity beams. To do so, a novel solid H2 /D2 target is used in combination with a low pressure ionization chamber for the identification of incoming beam particles. The light ejectiles are measured using a ΔE - E telescope consisting of an annular silicon detector followed by CsI(Tl) array. Another ΔE - E telescope, consisting of two segmented silicon detectors, is used to identify the heavy outgoing particles. An overview of the faciltity will be given and examples from recent experiments that illustrate that facility's capability for reaction studies of exotic nuclei will be shown. Support from Canada Foundation for Innovation, Nova Scotia Research and Innovation Trust and NSERC.
Iris Matching Based on Personalized Weight Map.
Dong, Wenbo; Sun, Zhenan; Tan, Tieniu
2011-09-01
Iris recognition typically involves three steps, namely, iris image preprocessing, feature extraction, and feature matching. The first two steps of iris recognition have been well studied, but the last step is less addressed. Each human iris has its unique visual pattern and local image features also vary from region to region, which leads to significant differences in robustness and distinctiveness among the feature codes derived from different iris regions. However, most state-of-the-art iris recognition methods use a uniform matching strategy, where features extracted from different regions of the same person or the same region for different individuals are considered to be equally important. This paper proposes a personalized iris matching strategy using a class-specific weight map learned from the training images of the same iris class. The weight map can be updated online during the iris recognition procedure when the successfully recognized iris images are regarded as the new training data. The weight map reflects the robustness of an encoding algorithm on different iris regions by assigning an appropriate weight to each feature code for iris matching. Such a weight map trained by sufficient iris templates is convergent and robust against various noise. Extensive and comprehensive experiments demonstrate that the proposed personalized iris matching strategy achieves much better iris recognition performance than uniform strategies, especially for poor quality iris images.
2013-06-25
VANDENBERG AIR FORCE BASE, Calif. – At Vandenberg Air Force Base in California, NASA hosted a prelaunch news conference on the Interface Region Imaging Spectrograph, or IRIS, solar observatory scheduled to launch on a Pegasus XL rocket. Participating in the news conference are George Diller, NASA Public Affairs, Geoffrey Yoder, deputy associate administrator for the Programs, Science Mission Directorate at NASA Headquarters in Washington, D.C., Tim Dunn, NASA launch director/NASA Launch Manager at the Kennedy Space Center in Florida, Bryan Baldwin, Pegasus launch vehicle program director for Orbital Sciences Corp. of Dulles, Va., Gary Kushner, IRIS project manager for Lockheed Martin's Solar and Astrophysics Laboratory in Palo Alto, Calif., and First Lt. Jennifer Kelley, launch weather officer for the U.S. Air Force 30th Operations Support Squadron at Vandenberg. Scheduled for launch from Vandenberg on June 26, 2013, IRIS will open a new window of discovery by tracing the flow of energy and plasma through the chromospheres and transition region into the sun’s corona using spectrometry and imaging. The IRIS mission will observe how solar material moves, gathers energy and heats up as it travels through a largely unexplored region of the solar atmosphere. The interface region, located between the sun's visible surface and upper atmosphere, is where most of the sun's ultraviolet emission is generated. These emissions impact the near-Earth space environment and Earth's climate. For more information, visit http://www.nasa.gov/iris Photo credit: NASA/ Daniel Casper
Comparison of ionospheric F2 peak parameters foF2 and hmF2 with IRI2001 at Hainan
NASA Astrophysics Data System (ADS)
Wang, X.; Shi, J. K.; Wang, G. J.; Gong, Y.
2009-06-01
Monthly median values of foF2, hmF2 and M(3000)F2 parameters, with quarter-hourly time interval resolution for the diurnal variation, obtained with DPS4 digisonde at Hainan (19.5°N, 109.1°E; Geomagnetic coordinates: 178.95°E, 8.1°N) are used to investigate the low-latitude ionospheric variations and comparisons with the International Reference Ionosphere (IRI) model predictions. The data used for the present study covers the period from February 2002 to April 2007, which is characterized by a wide range of solar activity, ranging from high solar activity (2002) to low solar activity (2007). The results show that (1) Generally, IRI predictions follow well the diurnal and seasonal variation patterns of the experimental values of foF2, especially in the summer of 2002. However, there are systematic deviation between experimental values and IRI predictions with either CCIR or URSI coefficients. Generally IRI model greatly underestimate the values of foF2 from about noon to sunrise of next day, especially in the afternoon, and slightly overestimate them from sunrise to about noon. It seems that there are bigger deviations between IRI Model predictions and the experimental observations for the moderate solar activity. (2) Generally the IRI-predicted hmF2 values using CCIR M(3000)F2 option shows a poor agreement with the experimental results, but there is a relatively good agreement in summer at low solar activity. The deviation between the IRI-predicted hmF2 using CCIR M(3000)F2 and observed hmF2 is bigger from noon to sunset and around sunrise especially at high solar activity. The occurrence time of hmF2 peak (about 1200 LT) of the IRI model predictions is earlier than that of observations (around 1500 LT). The agreement between the IRI hmF2 obtained with the measured M(3000)F2 and the observed hmF2 is very good except that IRI overestimates slightly hmF2 in the daytime in summer at high solar activity and underestimates it in the nighttime with lower values near sunrise at low solar activity.
IL233, A Novel IL-2 and IL-33 Hybrid Cytokine, Ameliorates Renal Injury.
Stremska, Marta E; Jose, Sheethal; Sabapathy, Vikram; Huang, Liping; Bajwa, Amandeep; Kinsey, Gilbert R; Sharma, Poonam R; Mohammad, Saleh; Rosin, Diane L; Okusa, Mark D; Sharma, Rahul
2017-09-01
CD4 + Foxp3 + regulatory T cells (Tregs) protect the kidney during AKI. We previously found that IL-2, which is critical for Treg homeostasis, upregulates the IL-33 receptor (ST2) on CD4 + T cells, thus we hypothesized that IL-2 and IL-33 cooperate to enhance Treg function. We found that a major subset of Tregs in mice express ST2, and coinjection of IL-2 and IL-33 increased the number of Tregs in lymphoid organs and protected mice from ischemia-reperfusion injury (IRI) more efficiently than either cytokine alone. Accordingly, we generated a novel hybrid cytokine (IL233) bearing the activities of IL-2 and IL-33 for efficient targeting to Tregs. IL233 treatment increased the number of Tregs in blood and spleen and prevented IRI more efficiently than a mixture of IL-2 and IL-33. Injection of IL233 also increased the numbers of Tregs in renal compartments. Moreover, IL233-treated mice had fewer splenic Tregs and more Tregs in kidneys after IRI. In vitro , splenic Tregs from IL233-treated mice suppressed CD4 + T cell proliferation better than Tregs from saline-treated controls. IL233 treatment also improved the ability of isolated Tregs to inhibit IRI in adoptive transfer experiments and protected mice from cisplatin- and doxorubicin-induced nephrotoxic injury. Finally, treatment with IL233 increased the proportion of ST2-bearing innate lymphoid cells (ILC2) in blood and kidneys, and adoptive transfer of ILC2 also protected mice from IRI. Thus, the novel IL233 hybrid cytokine, which utilizes the cooperation of IL-2 and IL-33 to enhance Treg- and ILC2-mediated protection from AKI, bears strong therapeutic potential. Copyright © 2017 by the American Society of Nephrology.
Desert Testing of Military Materiel.
1981-08-01
Uth toHitri Iin ’ pfcile P1O C I i tC 1 h Iri i n 0111I.i\\ C ’(cli1 ii’iii!, [It r!t iu iil I O tI ui. kI d i...the miajor dsrsate s’orldxtdc III ,0op( irid oe i, ;heir !i1i: er relat lollships,. A L rited Nations Conference oil l~e’er i 5ttoi I YT’ ilx, ssedI...34... [ratlre -- ’’Ttt -le, ’.-’.’d" I 0 %ko9ltae ra’ "q -,l, 1110.-q %rid’’ rf d.ff an a’.. t.!10.’-I o11,3 ,I ’ "" "a. ’I. .11 ’ 31 ~A’’ -W, 1-t4l>fqa ’ ga
Johnson, Andrew B.; Winker, Kevin
2010-01-01
Populations in fragmented ecosystems risk extirpation through natural disasters, which must be endured rather than avoided. Managing communities for resilience is thus critical, but details are sketchy about the capacity for resilience and its associated properties in vertebrate communities. We studied short-term resilience in a community of individually marked birds, following this community through the catastrophic destruction of its forest habitat by Hurricane Iris in Belize, Central America. We sampled for 58 d immediately before the storm, 28 d beginning 11 d after Hurricane Iris, and for 69 d approximately one year later. Our data showed that the initial capacity for resilience was strong. Many banded individuals remained after the storm, although lower post-hurricane recapture rates revealed increased turnover among individuals. Changes occurred in community dynamics and in abundances among species and guilds. Survivors and immigrants both were critical components of resilience, but in a heterogeneous, species-specific manner. Delayed effects, including higher fat storage and increased species losses, were evident one year later. PMID:21152062
Johnson, Andrew B; Winker, Kevin
2010-11-30
Populations in fragmented ecosystems risk extirpation through natural disasters, which must be endured rather than avoided. Managing communities for resilience is thus critical, but details are sketchy about the capacity for resilience and its associated properties in vertebrate communities. We studied short-term resilience in a community of individually marked birds, following this community through the catastrophic destruction of its forest habitat by Hurricane Iris in Belize, Central America. We sampled for 58 d immediately before the storm, 28 d beginning 11 d after Hurricane Iris, and for 69 d approximately one year later. Our data showed that the initial capacity for resilience was strong. Many banded individuals remained after the storm, although lower post-hurricane recapture rates revealed increased turnover among individuals. Changes occurred in community dynamics and in abundances among species and guilds. Survivors and immigrants both were critical components of resilience, but in a heterogeneous, species-specific manner. Delayed effects, including higher fat storage and increased species losses, were evident one year later.
Comparing TID simulations using 3-D ray tracing and mirror reflection
NASA Astrophysics Data System (ADS)
Huang, X.; Reinisch, B. W.; Sales, G. S.; Paznukhov, V. V.; Galkin, I. A.
2016-04-01
Measuring the time variations of Doppler frequencies and angles of arrival (AoA) of ionospherically reflected HF waves has been proposed as a means of detecting the occurrence of traveling ionospheric disturbances (TIDs). Simulations are made using ray tracing through the International Reference Ionosphere (IRI) electron density model in an effort to reproduce measured signatures. The TID is represented by a wavelike perturbation of the 3-D electron density traveling horizontally in the ionosphere with an amplitude that varies sinusoidally with time. By judiciously selecting the TID parameters the ray tracing simulation reproduces the observed Doppler frequencies and AoAs. Ray tracing in a 3-D realistic ionosphere is, however, excessively time consuming considering the involved homing procedures. It is shown that a carefully selected reflecting corrugated mirror can reproduce the time variations of the AoA and Doppler frequency. The results from the ray tracing through the IRI model ionosphere and the mirror model reflections are compared to assess the applicability of the mirror-reflection model.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-29
... period and a public listening session for the external review draft human health assessment titled... body established under the Federal Advisory Committee Act with a broad mandate to advise the Agency on.... Information about IRIS IRIS is a database that contains potential adverse human health effects information...