Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz
PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chibamore » needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.« less
Laser Recanalization of Central Venous Occlusion to Salvage a Threatened Arteriovenous Fistula.
Rambhia, Sagar; Janko, Matthew; Hacker, Robert I
2018-07-01
Central venous occlusion is conventionally managed with balloon angioplasty, stent extension, or sharp recanalization. Here, we describe recanalization of a chronically occluded innominate vein using excimer laser after conventional techniques were unsuccessful. Patient clinical improvement and fistula patency have been sustained 2 years postintervention. This technique may provide new hemodialysis access options for patients who would not otherwise be candidates for hemodialysis access on the ipsilateral side of a central venous occlusion. Copyright © 2018 Elsevier Inc. All rights reserved.
Lang, Elvira V; Reyes, Jorge; Faintuch, Salomao; Smith, Amy; Abu-Elmagd, Kareem
2005-09-01
To assess feasibility and success of venous recanalization in patients with short gut syndrome who have lost their traditional central venous access and required intestinal or multivisceral transplantation. Twelve patients between the ages of 7 and 55 years with short gut syndrome and long-standing total parenteral nutrition (TPN) dependency and/or hypercoagulability were treated. All had extensive chronic central venous occlusions and survival was dependent on restoration of access and planned transplantation. Central venous recanalizations were obtained via sharp needle recanalization techniques, venous reconstructions with stents, and/or extraanatomic access to the central venous system for placement of central venous tunneled catheters. Central venous access was restored in all patients without operative-related mortality. Three major hemodynamic perioperative technical complications were recorded and successfully treated. There were three self-limited early infectious complications. With a mean follow-up of 22 months, eight of the 12 patients were alive with successful small bowel or multivisceral transplantation; six of those became independent of TPN. The remaining four patients died of complications related to TPN (n = 3) or transplantation (n = 1). With a mean follow-up of 20 months, all but two of the recanalized venous accesses were maintained, for a success rate of 83%. Recanalizations of extensive chronic vein occlusions are feasible but associated with high risk. The technique is life-saving for TPN-dependent patients and can restore candidacy for intestinal and multivisceral transplantation. This approach is likely to be increasingly requested because of the current clinical availability of the transplant procedure.
Doshi, Ankur M; Hoffman, David; Kierans, Andrea S; Ream, Justin M; Rosenkrantz, Andrew B
2015-10-01
The objective of this study is to assess the performance of qualitative and quantitative imaging features for the differentiation of deep venous thrombosis (DVT) from mixing artifact on routine portal venous phase abdominopelvic CT. This retrospective study included 40 adult patients with a femoral vein filling defect on portal venous phase CT and a Duplex ultrasound (n = 36) or catheter venogram (n = 4) to confirm presence or absence of DVT. Two radiologists (R1, R2) assessed the femoral veins for various qualitative and quantitative features. 60% of patients were confirmed to have DVT and 40% had mixing artifact. Features with significantly greater frequency in DVT than mixing artifact (all p ≤ 0.006) were central location (R1 90% vs. 28%; R2 96% vs. 31%), sharp margin (R1 83% vs. 28%; R2 96% vs. 31%), venous expansion (R1 48% vs. 6%, R2 56% vs. 6%), and venous wall enhancement (R1 62% vs. 0%; R2 48% vs. 0%). DVT exhibited significantly lower mean attenuation than mixing artifact (R1 42.1 ± 20.2 vs. 57.1 ± 23.6 HU; R2 43.6 ± 19.4 vs. 58.8 ± 23.4 HU, p ≤ 0.031) and a significantly larger difference in vein diameter compared to the contralateral vein (R1 0.4 ± 0.4 vs. 0.1 ± 0.2 cm; R2 0.3 ± 0.4 vs. 0.0 ± 0.1 cm, p ≤ 0.026). At multivariable analysis, central location and sharp margin were significant independent predictors of DVT for both readers (p ≤ 0.013). Awareness of these qualitative and quantitative imaging features may improve radiologists' confidence for differentiating femoral vein DVT and mixing artifact on routine portal venous phase CT. However, given overlap with mixing artifact, larger studies remain warranted.
Association of physical examination with pulmonary artery catheter parameters in acute lung injury.
Grissom, Colin K; Morris, Alan H; Lanken, Paul N; Ancukiewicz, Marek; Orme, James F; Schoenfeld, David A; Thompson, B Taylor
2009-10-01
To correlate physical examination findings, central venous pressure, fluid output, and central venous oxygen saturation with pulmonary artery catheter parameters. Retrospective study. Data from the multicenter Fluid and Catheter Treatment Trial of the National Institutes of Health Acute Respiratory Distress Syndrome Network. Five hundred thirteen patients with acute lung injury randomized to treatment with a pulmonary artery catheter. Correlation of physical examination findings (capillary refill time >2 secs, knee mottling, or cool extremities), central venous pressure, fluid output, and central venous oxygen saturation with parameters from a pulmonary artery catheter. We determined association of baseline physical examination findings and on-study parameters of central venous pressure and central venous oxygen saturation with cardiac index <2.5 L/min/m2 and mixed venous oxygen saturation <60%. We determined correlation of baseline central venous oxygen saturation and mixed venous oxygen saturation and predictive value of a low central venous oxygen saturation for a low mixed venous oxygen saturation. Prevalence of cardiac index <2.5 and mixed venous oxygen saturation <60% was 8.1% and 15.5%, respectively. Baseline presence of all three physical examination findings had low sensitivity (12% and 8%), high specificity (98% and 99%), low positive predictive value (40% and 56%), but high negative predictive value (93% and 86%) for cardiac index <2.5 and mixed venous oxygen saturation <60%, respectively. Central venous oxygen saturation <70% predicted a mixed venous oxygen saturation <60% with a sensitivity 84%,specificity 70%, positive predictive value 31%, and negative predictive value of 96%. Low cardiac index correlated with cool extremities, high central venous pressure, and low 24-hr fluid output; and low mixed venous oxygen saturation correlated with knee mottling and high central venous pressure, but these correlations were not found to be clinically useful. In this subset of patients with acute lung injury, there is a high prior probability that cardiac index and mixed venous oxygen saturation are normal and physical examination findings of ineffective circulation are not useful for predicting low cardiac index or mixed venous oxygen saturation. Central venous oxygen saturation <70% does not accurately predict mixed venous oxygen saturation <60%, but a central venous oxygen saturation >or=70% may be useful to exclude mixed venous oxygen saturation <60%.
Duration and Adverse Events of Non-cuffed Catheter in Patients With Hemodialysis
2014-10-09
Renal Failure Chronic Requiring Hemodialysis; Central Venous Catheterization; Inadequate Hemodialysis Blood Flow; Venous Stenosis; Venous Thrombosis; Infection Due to Central Venous Catheter; Central Venous Catheter Thrombosis
Alonso-Quintela, Paula; Oulego-Erroz, Ignacio; Rodriguez-Blanco, Silvia; Muñiz-Fontan, Manoel; Lapeña-López-de Armentia, Santiago; Rodriguez-Nuñez, Antonio
2015-11-01
To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. Prospective observational study. PICU of a university hospital. Patients aged 0-14 who required a central venous catheter. None. Central venous catheter tip location was confirmed by ultrasound and chest radiography. Central venous catheters were classified as intra-atrial or extra-atrial according to their positions in relation to the cavoatrial junction. Central venous catheters located outside the vena cava were considered malpositioned. The distance between the catheter tip and the cavoatrial junction was measured. The time elapsed from image capture to interpretation was recorded. Fifty-one central venous catheters in 40 patients were analyzed. Chest radiography and ultrasound results agreed 94% of the time (κ coefficient, 0.638; p < 0.001) in determining intra-atrial and extra-atrial locations and 92% of the time in determining the diagnosis of central venous catheter malposition (κ coefficient, 0.670; p < 0.001). Chest radiography indicated a greater distance between the central venous catheter tip and the cavoatrial junction than measured by ultrasound, with a mean difference of 0.38 cm (95% CI, +0.27, +0.48 cm). Three central venous catheters were classified as extra-atrial by chest radiography but as intra-atrial by ultrasound. To locate the central venous catheter tip, ultrasound required less time than chest radiography (22.96 min [20.43 min] vs 2.23 min [1.06 min]; p < 0.001). Bedside ultrasound showed a good agreement with chest radiography in detecting central venous catheter tip location and revealing incorrect positions. Ultrasound could be a preferable method for routine verification of central venous catheter tip and can contribute to increased patient safety.
Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan
2012-05-01
To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.
Kotoda, Atsushi; Akimoto, Tetsu; Sugase, Taro; Yamamoto, Hisashi; Kusano, Eiji
2013-01-01
Central venous stenosis (CVS) is a serious complication for chronic hemodialysis (HD) patients. Previous reports of CVS have focused on prior central venous catheterization, because of the higher prevalence and potential for prevention of such an event. However, recent studies have demonstrated that CVS may also develop without a history of central venous catheterization. Although information about the etiological backgrounds regarding the development of CVS without previous central venous catheterization have gradually accumulated, the clinical impact of the chronic compression of the central venous system by the surrounding structures, which may likely determine the central venous susceptibility to CVS, remains poorly understood. This study proposes the hypothesis that the combination of chronic venous compression at the level of thoracic outlet characterized by the natural physique and elevated venous flow induced by the creation of vascular access should be evaluated as a potential factor for the development of CVS, since they may accelerate the development of venous stenosis, presumably through the stimulation of intimal hyperplasia, and thereby the subclavian venous susceptibility to CVS should be determined. Copyright © 2012 Elsevier Ltd. All rights reserved.
Risk factors associated with PICC-related upper extremity venous thrombosis in cancer patients.
Yi, Xiao-lei; Chen, Jie; Li, Jia; Feng, Liang; Wang, Yan; Zhu, Jia-An; Shen, E; Hu, Bing
2014-03-01
To investigate the incidence and risk factors for peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer. With the widespread use of peripherally inserted central venous catheters, peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer leads to increasing morbidity and mortality. It is very important to further explore the incidence and risk factors for peripherally inserted central venous catheters-related venous thrombosis. Consecutive patients with cancer who were scheduled to receive peripherally inserted central venous catheters, between September 2009 and May 2012, were prospectively studied in our centre. They were investigated for venous thrombosis by Doppler sonography three times a day within 30 days after catheter insertion. Univariable and multivariable logistic regressions' analyses were performed to identify the risk factors for peripherally inserted central venous catheters-related thrombosis. A total of 89 patients with cancer were studied in our research. Of these, 81 patients were followed up within one month. The mean interval between catheter insertion and the onset of thrombosis was 12.45 ± 6.17 days. The multivariable analyses showed that chemotherapy history, less activities and diabetes were the key risk factors for thrombosis. Peripherally inserted central venous catheters-related upper extremity venous thrombosis had high incidence rate, and most cases had no significant symptoms. The history of chemotherapy, less activities and diabetes were found to be the key risk factors. It should be routinely scanned in high-risk patients every 3-5 days after catheter insertion, which would then find blood clots in time and reduce the incidence of pulmonary embolism. Risk factors associated with peripherally inserted central venous catheters-related upper extremity venous thrombosis are of critical importance in improving the quality of patients' life. It is very important to grasp the indications to reduce the incidence rate of peripherally inserted central venous catheters-related upper extremity venous thrombosis. © 2013 John Wiley & Sons Ltd.
Rodrigues, Jorge; Dias, Andrea; Oliveira, Guiomar; Farela Neves, José
2016-06-01
To determine the central-line associated bloodstream infection rate after implementation of central venous catheter-care practice bundles and guidelines and to compare it with the previous central-line associated bloodstream infection rate. A prospective, longitudinal, observational descriptive study with an exploratory component was performed in a Pediatric Intensive Care Unit during five months. The universe was composed of every child admitted to Pediatric Intensive Care Unit who inserted a central venous catheter. A comparative study with historical controls was performed to evaluate the result of the intervention (group 1 versus group 2). Seventy five children were included, with a median age of 23 months: 22 (29.3%) newborns; 28 (37.3%) with recent surgery and 32 (43.8%) with underlying illness. A total of 105 central venous catheter were inserted, the majority a single central venous catheter (69.3%), with a mean duration of 6.8 ± 6.7 days. The most common type of central venous catheter was the short-term, non-tunneled central venous catheter (45.7%), while the subclavian and brachial flexure veins were the most frequent insertion sites (both 25.7%). There were no cases of central-line associated bloodstream infection reported during this study. Comparing with historical controls (group 1), both groups were similar regarding age, gender, department of origin and place of central venous catheter insertion. In the current study (group 2), the median length of stay was higher, while the mean duration of central venous catheter (excluding peripherally inserted central line) was similar in both groups. There were no statistical differences regarding central venous catheter caliber and number of lumens. Fewer children admitted to Pediatric Intensive Care Unit had central venous catheter inserted in group 2, with no significant difference between single or multiple central venous catheter. After multidimensional strategy implementation there was no reported central-line associated bloodstream infection Conclusions: Efforts must be made to preserve the same degree of multidimensional prevention, in order to confirm the effective reduction of the central-line associated bloodstream infection rate and to allow its maintenance.
Abdullah, Mohamed Hussein; Soliman, Hossam El Deen; Morad, Wessam Saber
2011-12-01
Many centers have adopted central vein cannulation both for central venous pressure monitoring and fluid administration for right hepatectomy in living-liver donors. However, use of central venous catheters is associated with adverse events that are hazardous to patients and expensive to treat. This study sought to examine the use of external jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies Forty ASA grade I adult living liver-donors without a known history of significant cardiac or pulmonary diseases were enrolled in this prospective observational study. Paired measurement of venous pressures (external jugular venous pressure and internal jugular venous pressure) were taken at the following times: after induction of anesthesia, 30 minutes after skin incision, during right lobe mobilization (every 15 minutes), during hepatic transaction (every 15 minutes), after right lobe resection (every 15 minutes), and after abdominal closure. Paired measurements were equal in 47.5%, 53.5%, 61.5%, 46.3%, and 52.5% for after induction, after skin incision, right lobe mobilization, right lobe transection, after resection, and before abdominal closure periods. However, all measurements were within acceptable limits of bias measurements (± 2 mm Hg). Central venous pressure catheter placement can be avoided and replaced by a less-invasive method such as external jugular venous pressure (which gave an acceptable estimate of central venous pressure in all phases of right lobe resection) in living-donor liver transplant and allowed equivalent monitor even during fluid restriction phases.
Nomura, Jason T; Sierzenski, Paul R; Nace, Jason E; Bollinger, Melissa
2008-07-01
Use of ultrasound guidance for Central Venous Catheter insertion has been associated with decreased complications and increased success rates. Previous reports show low rates of use among physicians. Evaluation of the frequency of Ultrasound Guidance use for Central Venous Catheter insertion among residents at a teaching institution. A cross sectional electronic survey of resident physicians at a tertiary care teaching hospital was conducted to evaluate use of Ultrasound Guidance for Central Venous Catheterization. Assessment included self reported frequency of ultrasound guidance use, and volume of central venous catheter placement. Attitudes toward the use of ultrasound were assessed using Likert scales. There is a high rate. over 90%, of ultrasound guidance use for Internal Jugular central venous catheters among residents. The majority of residents use sterile real-time imaging with a single operator with a reported success rate greater then 80%. Resident use of ultrasound guidance for Internal Jugular central venous catheter insertion can be much higher than previously reported in the literature.
1980-05-01
abnormalities in pressure tracings of the systemic, the central venous or pulmonary arterial circulation. At some sites (especially the Latter-Day Saints...accurate measurement of central venous pressure has been by direct venous cannulation. However, a group of Swiss doctors has extended the principle of... venous stop flow pressure to develop a noninvasive method of measuring central venous pressure. The method consists of venous auscultation at the thoracic
[The unnecessary application of central venous catheterization in surgical patients].
Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko
2018-04-06
Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on holidays, during low risk surgery, with a short duration of anesthesia, or in cases that do not require postoperative intensive care. Copyright © 2018 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Percutaneous transfemoral repositioning of malpositioned central venous catheters.
Hartnell, G G; Roizental, M
1995-04-01
Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.
Pathophysiology and Toxicokinetic Studies of Blue-Green Algae Intoxication in the Swine Model
1991-06-26
perfusion, renal perfusion, and mean arterial and central venous pressures were decreased, and portal pressure increased. Liver iron and hemoglobin indicated...the lethal dose, aortic mean pressure and central venous pressure decreased significantly, while portal venous pressure significantly increased. The...8217" recorded on a poiygraphY and logged on a hemodynamic analyzer. Mean aortic, central venous , and portal venous pressures were determined predosing
Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina
2017-07-01
Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.
Intravascular thrombosis as a result of central venous access.
Biernacka, Jadwiga; Nestorowicz, Andrzej; Wach, Małgorzata
2002-01-01
Central venous access represents one of the most basic therapeutic procedures in modern medicine. Unfortunately, numerous advantages that result from maintaining a central venous line are accompanied by some complications among which the venous thrombosis is the most significant clinically. The study was designed to assess frequency and natural history of this complication in the setting at a multi profile clinical hospital. Central venous cannulation was performed by a fully qualified anaesthesiologist in every case. There were 887 cannulations and only 5 patients with clinically significant venous thrombosis. The analysis of the collected data allowed us to state that the frequency of intravascular thrombosis is low, but this complication is often associated with extensive impairment of patency of the central veins. Full recanalization is not always achieved regardless of the treatment applied. Pulmonary embolism in the course of central venous thrombosis was diagnosed in one patient only and appeared as a multiple and fine X-ray infiltrates. It seems that in the presence of permanent or even life threatening complications of central venous thrombosis their risk should be minimized by frequent examination of the cannulation site and early initiation of antithrombotic treatment.
Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock
NASA Astrophysics Data System (ADS)
Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.
2013-03-01
Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.
The Toxicity of Inhaled Sulphur Mustard
2012-03-01
Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and venous ) pH pO2 pCO2 Sodium Potassium Calcium...Cardiovascular Parameters − CFI – Cardiac Function Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure...Data are expressed as mean ± SEM. Changes in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are
1983-01-01
7- peripheral intravenous route. CARE OF THE CENTRAL VENOUS CATHETER Central venous catheter insertion requires the follow- ing skin preparation: 1...receiving parenteral nutrition who develop sepsis from central venous catheters may show persistent temperature spikes to 38.9 *C to 40.0 *C every 12-24...hours. Evaluating the central venous catheter as the etiology for febrile episodes is often difficult because many patients have other potential
Changing concepts in long-term central venous access: catheter selection and cost savings.
Horattas, M C; Trupiano, J; Hopkins, S; Pasini, D; Martino, C; Murty, A
2001-02-01
Long-term central venous access is becoming an increasingly important component of health care today. Long-term central venous access is important therapeutically for a multitude of reasons, including the administration of chemotherapy, antibiotics, and total parenteral nutrition. Central venous access can be established in a variety of ways varying from catheters inserted at the bedside to surgically placed ports. Furthermore, in an effort to control costs, many traditionally inpatient therapies have moved to an outpatient setting. This raises many questions regarding catheter selection. Which catheter will result in the best outcome at the least cost? It has become apparent in our hospital that traditionally placed surgical catheters (ie, Hickmans and central venous ports) may no longer be the only options. The objective of this study was to explore the various modalities for establishing central venous access comparing indications, costs, and complications to guide the clinician in choosing the appropriate catheter with the best outcome at the least cost. We evaluated our institution's central venous catheter use during a 3-year period from 1995 through 1997. Data was obtained retrospectively through chart review. In addition to demographic data, specific information regarding catheter type, placement technique, indications, complications, and catheter history were recorded. Cost data were obtained from several departments including surgery, radiology, nursing, anesthesia, pharmacy, and the hospital purchasing department. During a 30-month period, 684 attempted central venous catheter insertions were identified, including 126 surgically placed central venous catheters, 264 peripherally inserted central catheters by the nursing service, and 294 radiologically inserted peripheral ports. Overall complications were rare but tended to be more severe in the surgical group. Relative cost differences between the groups were significant. Charges for peripherally inserted central catheters were $401 per procedure, compared with $3870 for radiologically placed peripheral ports and $3532 to $4296 for surgically placed catheters. Traditional surgically placed central catheters are increasingly being replaced by peripherally inserted central venous access devices. Significant cost savings and fewer severe complications can be realized by preferential use of peripherally inserted central catheters when clinically indicated. Cost savings may not be as significant when comparing radiologically placed versus surgically placed catheters. However, significant cost savings and fewer severe complications are associated with peripheral central venous access versus the surgical or radiologic approach.
Infection and natural history of emergency department-placed central venous catheters.
LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C
2010-11-01
Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
US Army Institute of Surgical Research Annual Research Progress Report for Fiscal Year 1987.
1987-10-01
oases, respiratory rate, chest roentgenograms), cardiovascular (blood pressure, central venous pressure, cardiac output), and renal (urine output, urine...Monitoring includes the precordial and/or esophageal stethoscope, peripheral pulse, blood pressure, central venous pressure, Swan-Ganz catheter... central venous , peripheral venous , and Swan-Ganz (7F, American Edward Laboratories, Irvine CA) catheters and an esophageal balloon were inserted. After a 2
Advanced Technologies in Trauma Critical Care Management
2012-01-01
CVL, central venous line; DVT, deep venous thrombosis; FAST, focused assessment with sonography for trauma; IVC, inferior vena cava; PIV, peripheral...either for a 1-time view of the target vein or in real time using a 1- or 2-person technique. Recently, ultrasound-guided subclavian central venous ...technologies such as bedside echocardiography, central venous pressure monitoring, and cardiac electrical velocimetry. These limitations aside, it is
Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas
2010-01-01
This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.
Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.
Ozmen, Evrim; Algin, Oktay
2016-07-12
Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.
Placement of a Port Catheter Through Collateral Veins in a Patient with Central Venous Occlusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teichgraeber, Ulf Karl-Martin, E-mail: ulf.teichgraeber@charite.de; Streitparth, Florian, E-mail: florian.streitparth@charite.d; Gebauer, Bernhard, E-mail: bernhard.gebauer@charite.d
Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition whenmore » required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.« less
Nerve conduction studies are safe in patients with central venous catheters.
London, Zachary N; Mundwiler, Andrew; Oral, Hakan; Gallagher, Gary W
2017-08-01
It is unknown if central venous catheters bypass the skin's electrical resistance and engender a risk of nerve conduction study-induced cardiac arrhythmia. The objective of this study is to determine if nerve conduction studies affect cardiac conduction and rhythm in patients with central venous catheters. Under continuous 12-lead electrocardiogram monitoring, subjects with and without central venous catheters underwent a series of upper extremity nerve conduction studies. A cardiologist reviewed the electrocardiogram tracings for evidence of cardiac conduction abnormality or arrhythmia. Ten control subjects and 10 subjects with central venous catheters underwent the nerve conduction study protocol. No malignant arrhythmias or conduction abnormalities were noted in either group. Nerve conduction studies of the upper extremities, including both proximal stimulation and repetitive stimulation, do not appear to confer increased risk of cardiac conduction abnormality in those patients with central venous catheters who are not critically ill or have a prior history of arrhythmia. Muscle Nerve 56: 321-323, 2017. © 2016 Wiley Periodicals, Inc.
DeLemos, Christi; Abi-Nader, Judy; Akins, Paul T
2011-04-01
Patients in neurological critical care units often have lengthy stays that require extended vascular access and invasive hemodynamic monitoring. The traditional approach for these patients has relied heavily on central venous and pulmonary artery catheters. The aim of this study was to evaluate peripherally inserted central catheters as an alternative to central venous catheters in neurocritical care settings. Data on 35 patients who had peripherally inserted central catheters rather than central venous or pulmonary artery catheters for intravascular access and monitoring were collected from a prospective registry of neurological critical care admissions. These data were cross-referenced with information from hospital-based data registries for peripherally inserted central catheters and subarachnoid hemorrhage. Complete data were available on 33 patients with Hunt-Hess grade IV-V aneurysmal subarachnoid hemorrhage. Catheters remained in place a total of 649 days (mean, 19 days; range, 4-64 days). One patient (3%) had deep vein thrombosis in an upper extremity. In 2 patients, central venous pressure measured with a peripherally inserted catheter was higher than pressure measured concurrently with a central venous catheter. None of the 33 patients had a central catheter bloodstream infection or persistent insertion-related complications. CONCLUSIONS Use of peripherally inserted central catheters rather than central venous catheters or pulmonary artery catheters in the neurocritical care unit reduced procedural and infection risk without compromising patient management.
Case report: Unilateral conduction hearing loss due to central venous occlusion.
Ribeiro, Phillip; Patel, Swetal; Qazi, Rizwan A
2016-05-07
Central venous stenosis is a well-known complication in patients with vascular access for hemodialysis. We report two cases involving patients on hemodialysis with arteriovenous fistulas who developed reversible unilateral conductive hearing loss secondary to critical stenosis of central veins draining the arteriovenous dialysis access. A proposed mechanism for the patients' reversible unilateral hearing loss is pterygoid venous plexus congestion leading to decreased Eustachian tube patency. Endovascular therapy was conducted to treat the stenosis and the hearing loss of both patients was returned to near normal after successful central venous angioplasty.
Hydrothorax after Central Venous Catheterization
Rudge, C. J.; Bewick, M.; McColl, I.
1973-01-01
Three patients are described who developed hydrothorax as a complication of central venous catheterization. Respiratory distress associated with physical signs of fluid in the chest should arouse suspicion that the venous catheter has perforated the wall of the vein. The complications of central venous catheterization are reviewed and three cases of hydrothorax are presented. Comments on the prevention of these complications, their diagnosis and treatment if they occur, are made. ImagesFIG. 1FIG. 2 PMID:4717421
Sharp Central Venous Recanalization by Means of a TIPS Needle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Honnef, Dagmar, E-mail: honnef@rad.rwth-aachen.de; Wingen, Markus; Guenther, Rolf W.
The purpose of this study was to perform an alternative technique for recanalization of a chronic occlusion of the left brachiocephalic vein that could not be traversed with a guidewire. Restoration of a completely thrombosed left brachiocephalic vein was attempted in a 76-year-old male hemodialysis patient with massive upper inflow obstruction, massive edema of the face, neck, shoulder, and arm, and occlusion of the stented right brachiocephalic vein/superior vena cava. Vessel negotiation with several guidewires and multipurpose catheters proved unsuccessful. The procedure was also non-viable using a long, 21G puncture needle. Puncture of the superior vena cava (SVC) at themore » distal circumference of the stent in the right brachiocephalic vein/superior vena cava, however, was feasible with a transjugular intrahepatic portosystemic shunt (TIPS) set under biplanar fluoroscopy using the distal end of the right brachiocephalic vein as a target, followed by balloon dilatation and partial extraction of thrombotic material of the left brachiocephalic vein with a wire basket. Finally, two overlapping stents were deployed to avoid early re-occlusion. Venography demonstrated complete vessel patency with free contrast media flow via the stents into the SVC, which was reconfirmed in follow-up examinations. Immediate clinical improvement was observed. Venous vascular recanalization of chronic venous occlusion by means of a TIPS needle is feasible as a last resort under certain precautions.« less
Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi
2016-02-01
Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.
Okada, Mari; Sato, Mai; Ogura, Masao; Kamei, Koichi; Matsuoka, Kentaro; Ito, Shuichi
2016-03-31
Advances in long-term parenteral nutrition via indwelling central venous catheter have improved the quality of life and mortality in patients with life-threatening gastrointestinal diseases complicated with severely impaired absorption. However, infection to central venous catheter is still a common and critical complication for such patients. We encountered two patients under long-term parenteral nutrition who developed glomerulonephritis associated with central venous catheter infection. Persistent bacterial infection in indwelling medical devices placed in the blood-stream such as a ventricular-atrial shunt is known to cause glomerulonephritis, a condition termed shunt nephritis. We reported the clinical manifestations, treatment and their pathological findings in the two patients with glomerulonephritis associated with central venous catheter infection. Both patients suffered from megacystis microcolon intestinal hypoperistalsis syndrome, a form of pseudo-Hirschsprung's disease. They had been receiving home parenteral nutrition via central venous catheter because of severe malabsorption. They presented proteinuria, hematuria, hypocomplementemia and positive PR3-antineutrophilic cytoplasmic antibody accompanied by Staphylococcus epidermidis infection in the central venous catheter. Their renal biopsy revealed membranoproliferative glomerulonephritis with positive C3 deposition. One of them recovered completely following the removal of catheter and administration of antibiotics, while another did not respond to the treatments. We then treated her with methylprednisolone pulse therapy followed by prednisolone. She responded well, and achieved complete remission. As central venous catheter infection-related glomerulonephritis has a similar etiology to shunt nephritis, removal of the catheter and administration of antibiotics is fundamental to the treatment. If a patient is resistant to such conventional therapy, additional steroid and/or immunosuppressive agent could be considered. Although the number of patients with classical shunt nephritis is decreasing since the ventricular-peritoneal shunt has become became the major procedure for hydrocephalus, central venous catheter infection-related glomerulonephritis may increase in the future due to a marked increase in the number of patients receiving long-term parenteral nutrition. Routine urinalysis should be considered in such patients for early detection of central venous catheter infection-related glomerulonephritis.
2014-01-01
Background Medical students often learn the skills necessary to perform a central venous catheterization in the operating room after simulator training. We examined the performance of central venous catheterization by medical students from the logbooks during their rotation in department of anesthesiology. Methods From the logbooks of medical students rotating in our department between January 2011 and June 2012, we obtained the kind and the number of central venous catheterization students had done, the results of the procedures whether they were success or failed, the reasons of the failures, complications, and the student self-reported confidence and satisfaction of their performance. Results There were 93 medical students performed 875 central venous catheterizations with landmark guidance on patients in the operating theater, and the mean number of catheterizations performed per student was 9.4 ± 2.0, with a success rate of 67.3%. Adjusted for age, sex, body mass index, surgical category, ASA score and insertion site, the odds of successful catherization improved with cumulative practice (odds ratio 1.10 per additional central venous catheterization performed; 95% confidence interval 1.05–1.15). The major challenge students encountered during the procedure was the difficulty of finding the central veins, which led to 185 catheterizations failed. The complication rate of central venous catheterization by the students was 7.8%, while the most common complication was puncture of artery. The satisfaction and confidence of students regarding their performance increased with each additional procedure and decreased significantly if failure or complications had occurred. Conclusion A student logbook is a useful tool for recording the actual procedural performance of students. From the logbooks, we could see the students’ performance, challenges, satisfaction and confidence of central venous catheterization were improved through cumulative clinical practice of the procedure. PMID:25123826
Ablordeppey, Enyo A; Drewry, Anne M; Beyer, Alexander B; Theodoro, Daniel L; Fowler, Susan A; Fuller, Brian M; Carpenter, Christopher R
2017-04-01
We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.
The Toxicity of Inhaled Sulphur Mustard
2012-10-01
Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure − DO2 – Oxygen Delivery − dpMax – Maximum...in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are expressed as mean ± SEM. UK UNCLASSIFIED Page 64 of...Respiratory rate (RR) Heart rate (HR) Expired CO2 Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and
NASA Technical Reports Server (NTRS)
Mark, A. L.; Takeshita, A.; Eckberg, D. L.; Abboud, F. M.
1978-01-01
Measurements were made of sinus node responses to arterial baroreceptor stimulation with phenylephrine injection or neck suction, before and during changes of central venous pressure provoked by lower body negative pressure or leg and lower truck elevation. Variations of central venous pressure between 1.1 and 9.0 mm Hg did not influence arterial baroreflex mediated bradycardia. Baroreflex sinus node responses were augmented by intravenous propranolol, but the level of responses after propranolol was comparable during the control state, lower body negative pressure, and leg and trunk elevation. Sinus node responses to very brief baroreceptor stimuli applied during the transitions of central venous pressure also were comparable in the three states. The authors conclude that physiological variations of central venous pressure do not influence sinus node responses to arterial baroreceptor stimulation in man.
Sjödin, Carl; Sondergaard, Soren; Johansson, Lotta
2018-06-01
The phlebostatic axis is the most commonly used anatomical external reference point for central venous pressure measurements. Deviation in the central venous pressure transducer alignment from the phlebostatic axis causes inadequate pressure readings, which may affect treatment decisions for critically ill patients in intensive care units. The primary aim of the study was to assess the variability in central venous pressure transducer levelling in the intensive care unit. We also assessed whether patient characteristics impacted on central venous pressure transducer alignment deviation. A sample of 61 critical care nurses was recruited and asked to place a transducer at the appropriate level for central venous pressure measurement. The measurements were performed in the intensive care unit on critically ill patients in supine and Fowler's positions. The variability among the participants using eyeball levelling and a laser levelling device was calculated in both sessions and adjusted for patient characteristics. A significant variation was found among critical care nurses in the horizontal levelling of the pressure transducer placement when measuring central venous pressure in the intensive care unit. Using a laser levelling device did not reduce the deviation from the phlebostatic axis. Patient characteristics had little impact on the deviation in the measurements. The anatomical external landmark for the phlebostatic axis varied between critical care nurses, as the variation in the central venous pressure transducer placement was not reduced with a laser levelling device. Standardisation of a zero-level for vascular pressures should be considered to reduce the variability in vascular pressure readings in the intensive care unit to improve patient treatment decisions. Further studies are needed to evaluate critical care nurses' knowledge and use of central venous pressure monitoring and whether assistive tools and/or routines can improve the accuracy in vascular pressure measurements in intensive care units. Copyright © 2018 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Lymphatic Leak Complicating Central Venous Catheter Insertion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnacle, Alex M., E-mail: alexbarnacle@yahoo.co.uk; Kleidon, Tricia M.
2005-12-15
Many of the risks associated with central venous access are well recognized. We report a case of inadvertent lymphatic disruption during the insertion of a tunneled central venous catheter in a patient with raised left and right atrial pressures and severe pulmonary hypertension, which led to significant hemodynamic instability. To our knowledge, this rare complication is previously unreported.
Jenkins, Glyndwr W; Kelly, Michael; Anwar, Siddiq; Ahmed, Saeed S
2015-01-01
Vascular access has been described in the literature anywhere from the 'Achilles Heel' to the 'Cornerstone' of haemodialysis. Displacement of a central venous catheter is not an uncommon occurrence. We discuss an alternative method of placement for the tunnelled central venous catheter to prevent displacement in those patients with excess anterior chest wall soft tissue. A new surgical technique for placement of a tunnelled central venous catheter was developed in an attempt to reduce the number of displacements. This involved the creation of a second tunnel at a 90° angle to the original retrograde tunnelled path. The authors have currently placed five 'S-Line' tunnelled central venous catheters with no reports of displacement or line infection over a period of 18 months. The 'S-Line' offers a simple, straightforward and most importantly safe method to reduce the incidence of tunnelled right internal jugular central venous catheter displacement.
Central Venous Catheter Insertion Site and Colonization in Pediatric Cardiac Surgery
2017-11-04
Central Line-associated Bloodstream Infection (CLABSI); Central Venous Catheter Associated Bloodstream Infection; Heart; Surgery, Heart, Functional Disturbance as Result; Congenital Heart Disease; Newborn; Infection
Burn Treatment: Annual Research Progress Report.
1975-06-30
in addition to direct or indirect measurements of blood pressure. Central venous pressures are measured relatively frequently and, on occasion, a... Central venous pressure assessment. 5. EKG. 46 I 6. Sponge weighing. 7. Measurement of urine output during surgery. B. RESPIRATION 1. Counting of...start a central venous line prior to adminis- tration of vasopressors. The patient became progressively more hypo- tensive and bradycardiac, which
Pacific Pediatric Advanced Care Initiative
2009-10-01
Prepare IV ports: Identify IV ports (UVC, Femoral venous line, other central venous lines, or PIV) for easy access to push meds or administer volume...Supply Department CVL central venous line CXR chest xray DC discontinue DI Diagnostic Imaging DIC disseminated intravascular coagulation diff...programs at KMCWC. These include the blood bank, blood utilization committee, clinical laboratories, operating room, central supply, pharmacy
Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J
2016-07-01
Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.
Ablordeppey, Enyo A.; Drewry, Anne M.; Beyer, Alexander B.; Theodoro, Daniel L.; Fowler, Susan A.; Fuller, Brian M.; Carpenter, Christopher R.
2016-01-01
Objective We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared to chest radiography. Data Sources PubMed, EMBASE, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov Study Selection Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2×2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, inter-rater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Data Extraction Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Data Synthesis 15 studies with 1553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 [0.77, 0.86] and 0.98 [0.97, 0.99] respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 [14.72, 65.78] and 0.25 [0.13, 0.47]. The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Conclusions Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography. PMID:27922877
Closed-Loop Control of Fluid Therapy for Treatment of Hypovolemia
2008-04-01
index) (Table 2). Invasive bladder catheterization and blood sampling add the use of urinary output, lactate, central venous oxygen saturation, he...for guiding burn resuscitation Time delay, renal failure, and drugs complicate interpretation Central venous oxygenation ScvO2 Global perfusion index... Central venous pressure (CVP) Sensitive to volume change Pre-injury baseline values vary Arterial pressure by transducer Real-time continuous
2008 International Meeting on Simulation in Healthcare
2008-05-01
procedural simulator to teach central venous catheterization (CVC). METHODS: Fourth year medical students (n 12) at the Medical College of Georgia...RESEARCH ABSTRACT 51 Use of A Variety of Simulation Modalities in a Graduate Medical Education Safety Initiative on Central Venous Catheterization Walter...events associated with central venous catheterization (CVC) procedures is well-established.1–2 The overall goal of this multidis- ciplinary project
Positive Fungal Cultures in Burn Patients: A Multicenter Review
2008-02-01
These factors include neutropenia, systemic ste- roids, central venous access,39 TPN, hemodialysis, diabetes mellitus, and urinary catheterization .40...burn treatment exposes patients to multiple other risks for fungal infection, including central venous lines, uri- nary catheters, prolonged...patients with central venous *See appendix for complete list of participants and institutions. This work was supported in part by a grant from Merck & Co
U. S. Army Medical Research and Development Technical Report
1978-09-30
skin preparation prior to cathe- ter insertion, thi- type of catheter care following insertion, and the duration of central venous catheterization . An...NO. 3 A study is now underway to determine the optimal techniques for central venous catheter dressing care. A specially designed dress- ing tray that...chronically maintained male rhesus monkeys with indwelling central venous catheters. Two specific problems were en- countered. (1) Available data
Central Venous Catheter (Central Line)
... the skin entry site. With care, central venous catheters can remain in the body for several months without becoming infected. ■ ■ Blocking or kinking— Blood clots may begin to form in the catheter but ...
Crozer-Chester Medical Center Burn Research Project
2013-09-01
description of findings reported for CT scans, echocardiograms, cardiac catheterizations , chest x-ray reports, and measurements of central venous pressure...epithelial autografts (CEA) in patients with massive burn injuries. Central venous catheter exchange strategies in patients with acute burn injury at...had complete data. Culture data were stratified by type: sputum (SCx) (5.4 ±4.7 Cx/Patient), central venous catheter (CVCx) (2.1 ±2.4 Cx/Patient
Journal of Special Operations Medicine. Volume 9, Edition 3, Summer 2009
2009-01-01
consist of a central venous catheter placed within the in- ferior vena cava. Cooled saline is pushed through the catheter balloons, which are in...water immersion has both cardio- vascular and pulmonary effects. Increased venous re- turn leads to central pooling of blood, which thereby...Induced Pulmonary Edema (SIPE) 49 11. Norsk P, Bonde-Petersen F, Warberg J. (1986). Central venous pressure and plasma arginine vasopressin in man
The 12th Annual International Meeting on Simulation Healthcare (IMSH) 2012
2012-03-01
Title: Videorecording of Simulated Technical Errors as an Instructional Modality in a Central Venous Catheterization Course Sub Content: Knowledge...bedside procedures, such as insertion of peripheral and central venous catheters, are performed routinely by a wide spectrum of healthcare providers...with Chest Tubes and a Central Venous Line Monday January 30th 2012 4:00 pm – 5:15 pm Training Education and Assessment Shelby Marx, Donald
Isaza-Restrepo, Andres; Moreno-Mejia, Jose F; Martin-Saavedra, Juan S; Ibañez-Pinilla, Milciades
2017-01-01
There is a well known relationship between hypoperfusion and postoperative complications like anastomotic leak. No studies have been done addressing this relationship in the context of abdominal trauma surgery. Central venous oxygen saturation is an important hypoperfusion marker of potential use in abdominal trauma surgery for identifying the risk of anastomotic leak development. The purpose of this study was to identify the relationship between low values of central venous oxygen saturation and anastomotic leak of gastrointestinal sutures in the postoperative period in abdominal trauma surgery. A cross-sectional prospective study was performed. Patients over 14 years old who required surgical gastrointestinal repair secondary to abdominal trauma were included. Anastomotic leak diagnosis was confirmed through clinical manifestations and diagnostic images or secondary surgery when needed. Central venous oxygen blood saturation was measured at the beginning of surgery through a central catheter. Demographic data, trauma mechanism, anatomic site of trauma, hemoglobin levels, abdominal trauma index, and comorbidities were assessed as secondary variables. Patients who developed anastomotic leak showed lower mean central venous oxygen saturation levels (60.0% ± 2.94%) than those who did not (69.89% ± 7.21%) ( p = 0.010). Central venous oxygen saturation <65% was associated with the development of gastrointestinal leak during postoperative time of patients who underwent surgery secondary to abdominal trauma.
[Venous thrombosis associated with central venous catheter use in patients with cancer].
Iglesias Rey, Leticia; Fernández Pérez, Isaura; Barbagelata López, Cristina; Rivera Gallego, Alberto
2015-01-01
The use of central venous catheters for various applications (administration of chemotherapy, blood products and others) in patients with cancer is increasingly frequent. The association between thrombosis and catheter use has been fully established but aspects such as its causes, diagnosis, prophylaxis and treatment have not. We describe a case of thrombosis in a patient with cancer treated with chemotherapy who carried a central venous catheter. We also perform a review of the risk factors, the role of the prophylaxis and the treatment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Central line-associated venous late effects in children without prior history of thrombosis.
Ruud, Ellen; Holmstrøm, Henrik; Hopp, Einar; Wesenberg, Finn
2006-09-01
The frequency of asymptomatic central line-associated thromboses is high and well recognized among children with cancer, while the long-term consequences are mainly unknown. In a cross-sectional study, we evaluated clinical and radiological venous outcome in children with previous long-standing intravascular catheters. The study enrolled 71 children previously treated for malignant or haematological diseases, 4-180 (median 37) mo after removal of their central lines. Inclusion criteria were a prior central line in a jugular vein for a minimum of 6 mo and no previous history of thrombosis. The children had clinical examination for post-thrombotic syndrome (PTS) and Doppler ultrasonography of the central neck veins. Twelve children had additional venous magnetic resonance imaging (MRI). But no kind of venography was performed in the remaining. We observed mild PTS with increased superficial collaterals in four children (6%), but no cases of more severe PTS. None complained of symptoms related to venous late effects. By ultrasonography, post-thrombotic venous alterations were detected in 17 children (24%), and five of these had complete occlusion of the veins. The sensitivity for pathologically increased collaterals to identify occlusive thrombosis was 0.6, while the specificity was 0.98. Occlusive venous thromboembolism was associated with the total number of central venous lines (CVLs; p=0.002), previous severe CVL-associated infections (p=0.001) and duration of central line in place (p=0.042). In spite of no prior history of thrombosis, children with previous long-term jugular lines frequently had local thrombotic sequelae, while clinical symptoms of PTS were rare.
Labeau, Sonia O; Vandijck, Dominique M; Rello, Jordi; Adam, Sheila; Rosa, Ana; Wenisch, Christoph; Bäckman, Carl; Agbaht, Kemal; Csomos, Akos; Seha, Myriam; Dimopoulos, George; Vandewoude, Koenraad H; Blot, Stijn I
2009-01-01
To determine European intensive care unit (ICU) nurses' knowledge of guidelines for preventing central venous catheter-related infection from the Centers for Disease Control and Prevention. Multicountry survey (October 2006-March 2007). Twenty-two European countries. ICU nurses. Using a validated multiple-choice test, knowledge of ten recommendations for central venous catheter-related infection prevention was evaluated (one point per question) and assessed in relation to participants' gender, ICU experience, number of ICU beds, and acquisition of a specialized ICU qualification. We collected 3405 questionnaires (70.9% response rate); mean test score was 44.4%. Fifty-six percent knew that central venous catheters should be replaced on indication only, and 74% knew this also concerns replacement over a guidewire. Replacing pressure transducers and tubing every 4 days, and using coated devices in patients requiring a central venous catheter >5 days in settings with high infection rates only were recognized as recommended by 53% and 31%, respectively. Central venous catheters dressings in general are known to be changed on indication and at least once weekly by 43%, and 26% recognized that both polyurethane and gauze dressings are recommended. Only 14% checked 2% aqueous chlorhexidine as the recommended disinfection solution; 30% knew antibiotic ointments are not recommended because they trigger resistance. Replacing administration sets within 24 hrs after administering lipid emulsions was recognized as recommended by 90%, but only 26% knew sets should be replaced every 96 hrs when administering neither lipid emulsions nor blood products. Professional seniority and number of ICU beds showed to be independently associated with better test scores. Opportunities exist to optimize knowledge of central venous catheter-related infection prevention among European ICU nurses. We recommend including central venous catheter-related infection prevention guidelines in educational curricula and continuing refresher education programs.
2014-01-01
Background Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid and accurate. It is unclear, however, whether ultrasound real-time guidance and examination can reduce procedure times and complication rates when compared with landmark guidance and radiographic examination for SCV catheterization. Methods/Design The Subclavian Central Venous Catheters Guidance and Examination by UltraSound (SUBGEUS) study is an investigator-initiated single center, randomized, controlled two-arm trial. Three hundred patients undergoing SCV catheter placement will be randomized to ultrasound real-time guidance and examination or landmark guidance and radiographic examination. The primary outcome is the time between the beginning of the procedure and control of the catheter. Secondary outcomes include the times required for the six components of the total procedure, the occurrence of complications (pneumothorax, hemothorax, or misplacement), failure of the technique and occurrence of central venous catheter infections. Discussion The SUBGEUS trial is the first randomized controlled study to investigate whether ultrasound real-time guidance and examination for SCV catheter placement reduces all procedure times and the rate of complications. Trial registration ClinicalTrials.gov Identifier: NCT01888094 PMID:24885789
Eide, Per Kristian; Ringstad, Geir
2017-02-01
We have previously proposed that pineal cysts (PCs) may result in crowding of the pineal recess, causing symptoms due to compression of the internal cerebral veins and central venous hypertension. In the present study, we compared clinical outcome of different treatment modalities in symptomatic individuals with non-hydrocephalic PCs. The study included all patients managed surgically for non-hydrocephalic PCs in our Department of Neurosurgery over a 10-year period. We applied a questionnaire to determine occurrence of symptoms before and after surgery, which allowed the use of a grading scale for symptom severity. Magnetic resonance imaging (MRI) biomarkers indicative of central venous hypertension were assessed before and after surgery. Relief of symptoms after surgery was most efficiently obtained by complete microsurgical cyst removal [n = 15; no (0/15), some (1/15) or marked (14/15) improvement], and to a lesser extent by microsurgical cyst fenestration [n = 6; no (2/6), some (4/6) or marked (0/6) improvement]. Shunt surgery was not successful [n = 6; no (5/6), some (1/6) or marked (0/6) improvement]. In all patients, the proposed MRI biomarkers gave evidence of central venous hypertension (PC grades 2-4). Microsurgical cyst removal provided marked symptom relief in symptomatic individuals with non-hydrocephalic PCs and MRI biomarkers of central venous hypertension. The hypothesis that PC-induced crowding of the pineal recess may compromise venous run-off and induce a central venous hypertension syndrome deserves further study.
Meecham, Lewis; Fisher, Owain; Kirby, George; Evans, Richard; Buxton, Pauline; Legge, Jocelyn; Rajagopalan, Sriram; Asquith, John; Pherwani, Arun
2016-10-01
We present a case of external iliac vein patch venoplasty to accommodate rescue vascular access via a polytetrafluoroethylene loop arteriovenous fistula graft (AVG) for a patient with multiple central venous stenoses. A 35-year-old female with anti-glomerular basement membrane antibody disease required rescue vascular access for hemodialysis. Repeated occlusion and/or thrombosis of long-term central venous access cannulae, to facilitate dialysis, had caused stenosis of brachiocephalic veins: right external iliac vein and occlusion of the left common iliac vein. A previous right brachiobasilic fistula had occluded within 1 year. No other upper limb options for arteriovenous fistula (AVF) were available. A right external iliac vein bovine patch angioplasty concurrently with a polytetrafluoroethylene AV graft between common femoral artery and common femoral vein was performed to restore venous patency and allow rescue dialysis access. At 3-year follow-up, the fistula remains widely patent with 2 L/min flow rates and no recurrent stenosis to the treated iliac vein. She has not required any further surgical or interventional radiological procedures to maintain fistula or central venous patency. Central venous stenosis or occlusion is common for patients requiring dialysis, especially those with multiple previous long-term central venous cannulations. If restriction of outflow is present, AVF may fail. Venous patch angioplasty in these cases is a successful technique, allowing AVF formation and long-term patency. Central venous stenosis can be treated successfully with patch venoplasty to accommodate AVF/AVG formation for rescue vascular access; this is a potentially lifesaving intervention for patients requiring dialysis. Copyright © 2016 Elsevier Inc. All rights reserved.
Murga, Allen G; Chiriano, Jason T; Bianchi, Christian; Sheng, Neha; Patel, Sheela; Abou-Zamzam, Ahmed M; Teruya, Theodore H
2017-07-01
Central venous occlusion is a common occurrence in patients with end-stage renal disease. Placement of upper extremity arteriovenous access in patients with occlusion of the brachiocephalic veins is often not an option. Avoidance of lower extremity vascular access can decrease morbidity and infection. The central venous lesions were crossed centrally via femoral access. The wire was retrieved in the neck extravascularly. A Hemodialysis Reliable Outflow catheter was then placed in the right atrium and completed with an arterial anastomosis. We describe a novel technique for placing upper extremity arteriovenous access in patients with occlusion of the brachiocephalic veins. This technique was utilized in 3 patients. The technical success was 100%. The placement of upper extremity arteriovenous access in patients with central venous occlusions is technically feasible. Published by Elsevier Inc.
Diaz, Katrina; Kelly, Sean G; Smith, Barbara; Malani, Preeti N; Younger, John G
2012-02-01
Despite successful efforts to improve overall central line-associated bloodstream infections (CLABSI) rates, little is known about CLABSI rates or even central venous catheter insertion practices in the Emergency Department. We sought to determine the baseline CLABSI rate for Emergency Department-inserted central venous catheters and to describe indications for placement, duration of use, and the natural history of these devices. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Flanigan, Robert C; Polcari, Anthony J; Shore, Neil D; Price, Thomas H; Sims, Robert B; Maher, Johnathan C; Whitmore, James B; Corman, John M
2013-02-01
Sipuleucel-T is an autologous cellular immunotherapy. We review the safety of the leukapheresis procedure required for sipuleucel-T preparation and complications related to venous catheter use in the randomized, placebo controlled phase 3 IMPACT (IMmunotherapy for ProstAte Cancer Trial) study (NCT 00065442). A total of 512 patients with asymptomatic or minimally symptomatic metastatic castrate resistant prostate cancer were enrolled in the study. All patients were scheduled to undergo 3 standard 1.5 to 2.0 blood volume leukapheresis procedures at 2-week intervals. Leukapheresis related adverse events and those related to venous catheter use were reviewed. Immune cell counts were examined throughout the treatment course. Of 512 enrolled patients 506 underwent 1 or more leukapheresis procedures and were included in this analysis. Adverse events were comparable between the sipuleucel-T and control arms. Leukapheresis related adverse events were primarily associated with transient hypocalcemia (39.3%). Most leukapheresis related adverse events (97%) were of mild/moderate intensity. Median white blood cell count and absolute monocyte and lymphocyte counts were stable and within normal ranges throughout the treatment course. Of all patients 23.3% had a central venous catheter placed primarily for leukapheresis. Patients with vs without a central venous catheter had a higher risk of infection potentially related to catheter use (11.9% vs 1.3%, p <0.0001) and a trend toward a higher incidence of venous vascular events potentially related to catheter use, excluding the central nervous system (5.9% vs 2.1%, p = 0.06). Adverse events related to leukapheresis are manageable and quickly reversible. The majority of patients can undergo leukapheresis without a central venous catheter. Central venous catheters are associated with an increased risk of infections and venous vascular events. Peripheral intravenous access should be used when feasible. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Helder, Onno; Kornelisse, René; van der Starre, Cynthia; Tibboel, Dick; Looman, Caspar; Wijnen, René; Poley, Marten; Ista, Erwin
2013-10-14
Central venous catheter-associated bloodstream infections in children are an increasingly recognized serious safety problem worldwide, but are often preventable. Central venous catheter bundles have proved effective to prevent such infections. Successful implementation requires changes in the hospital system as well as in healthcare professionals' behaviour. The aim of the study is to evaluate process and outcome of implementation of a state-of-the-art central venous catheter insertion and maintenance bundle in a large university children's hospital. An interrupted time series design will be used; the study will encompass all children who need a central venous catheter. New state-of-the-art central venous catheter bundles will be developed. The Pronovost-model will guide the implementation process. We developed a tailored multifaceted implementation strategy consisting of reminders, feedback, management support, local opinion leaders, and education. Primary outcome measure is the number of catheter-associated infections per 1000 line-days. The process outcome is degree of adherence to use of these central venous catheter bundles is the secondary outcome. A cost-effectiveness analysis is part of the study. Outcomes will be monitored during three periods: baseline, pre-intervention, and post-intervention for over 48 months. This model-based implementation strategy will reveal the challenges of implementing a hospital-wide safety program. This work will add to the body of knowledge in the field of implementation. We postulate that healthcare workers' willingness to shift from providing habitual care to state-of-the-art care may reflect the need for consistent care improvement. Trial registration: Dutch trials registry, trial # 3635. Dutch trials registry (http://www.trialregister.nl), trial # 3635.
Central venous access: techniques and indications in oncology.
Marcy, Pierre-Yves
2008-10-01
Long lines can be inserted centrally or peripherally through patent veins into the central venous system down to the atrial caval junction. Traditionally surgeons, anesthetists, cardiologists and more recently interventional radiologists have been placing them using vein cutdown or percutaneous needle puncture techniques. Typical candidates for implanted venous catheters are cancer patients undergoing long-term chemotherapy. The most important issues, in addition to the patency of central veins and the history of previous indwelling catheters, pacewires or venous thrombosis, are the patient's performance status, body mass index, medical history and respiratory status, and the relevant technique. The present article will give an overview of the radiological and surgical implantation techniques and will highlight the impact of imaging means on the technical feasibility, assessment and treatment of device-related complications.
Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro
2014-01-01
The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.
Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonsalves, Carin F., E-mail: Carin.Gonsalves@mail.tju.edu; Eschelman, David J.; Sullivan, Kevin L.
2003-04-15
The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine cathetermore » dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices.Patients with longer catheter dwell time were more likely to develop central vein abnormalities. In order to preserve vascular access for dialysis fistulae and grafts and adhere to Dialysis Outcomes Quality Initiative guidelines, alternative venous access sites should be considered for patients with chronic renal insufficiency and end-stage renal disease.« less
US Army Institute of Surgical Research Annual Research Progress Report FY 1982.
1982-10-01
arterial blood gases, respiratory rate, daily chest roentgenograms), cardiovascular (blood pressure, central venous pressure, cardiac output measured...confirmed by the finding that central venous plasma histamine rose from 3.79 + 0.86 to 77.58 + 27.28 and 74.22 + 32.79 ng/ml at one and two minutes postburn...wounds at 2 - 4 weeks after injury. Central venous indwelling catheters were placed via the right jugular vein on the day prior to use as previously
2016-12-01
repair, bowel anastomosis, central venous catheterization , and bladder catheterization . We performed a multivariate analysis of variance (MANOVA) to...DC, Gould MK. Preventing complications of central venous catheterization . N Engl J Med 2003;348:1123–33. 15. Maithel S, Sierra R, Korndorffer J, et...subclavian-vein catheterization . N Engl J Med. 1994;331(26):1735-1738. 2. Taylor RW, Palagiri AV. Central venous catheter- ization. Crit Care Med. 2007;35(5
Central Venous Catheter-related Fungemia Caused by Rhodotorula glutinis.
Miglietta, Fabio; Letizia Faneschi, Maria; Braione, Adele; Palumbo, Claudio; Rizzo, Adriana; Lobreglio, Giambattista; Pizzolante, Maria
2015-01-01
Bloodstream infection due to Rhodotorula glutinis is extremely rare and mostly associated with underlying immunosuppression or cancer. Vascular access devices provide the necessary surfaces for biofilm formation and are currently responsible for a significant percentage of human infections. In this work, we describe a rare case of central venous catheter-related Rhodotorula glutinis fungemia in a female patient with acute myelogenous leukemia in remission. The timely removal of central venous catheter was an essential element for overcoming this CVC-related Rhodotorula fungemia.
Rodrigues, A F; van Mourik, I D M; Sharif, K; Barron, D J; de Giovanni, J V; Bennett, J; Bromley, P; Protheroe, S; John, P; de Ville de Goyet, J; Beath, S V
2006-04-01
The 3-year survival after small bowel transplantation (SBTx) has improved to between 73% and 88%. Impaired venous access for parenteral nutrition can be an indication for SBTx in children with chronic intestinal failure. To report our experience in management of children with extreme end-stage venous access. The study consisted of 6 children (all boys), median age of assessment 27 months (range, 13-52 months), diagnosed with total intestinal aganglionosis (1), protracted diarrhea (1), and short bowel syndrome (4), of which gastroschisis (2) and malrotation with midgut volvulus (2) were the causes. All had a documented history of more than 10 central venous catheter insertions previously. All had venograms, and 1 child additionally had a magnetic resonance angiogram to evaluate venous access. Five of 6 presented with thrombosis of the superior vena cava (SVC) and/or inferior vena cava. Venous access was reestablished as follows: transhepatic venous catheters (5), direct intra-atrial catheter via midline sternotomy (4), azygous venous catheters (2), dilatation of left subclavian vein after passage of a guide wire and then placing a catheter to reach the right atrium (1), radiological recanalization of the SVC and placement of a central venous catheter in situ (1), and direct puncture of SVC stump(1). Complications included serous pleural effusion after direct intra-atrial line insertion, which resolved after chest drain insertion (1), displacement of transhepatic catheter needing repositioning (2), and SVC stent narrowing requiring repeated balloon dilatation. Four children with permanent intestinal failure on assessment were offered SBTx, 3 of which were transplanted and were established on full enteral nutrition; the family of 1 child declined the procedure. In the remaining 2 children in whom bowel adaptation was still a possibility, attempts were made to provide adequate central venous access as feeds and drug manipulations were undertaken. One of them received liver and SBTx nearly 3 years after presenting with end-stage central venous access, because attempts to achieve independence from parenteral nutrition had failed. The other child died immediately after a transhepatic venous catheter placement, possibly from a nutritional depletion syndrome as no physical cause of death was found. Direct intra-atrial catheters in transplanted children proved to be adequate for the management of uncomplicated transplantation, although the usual infusion protocol had to be modified considerably, and the lack of access would have been critical if massive blood transfusion had been required during the transplant procedure. It was possible to reestablish central venous access in all cases. However, this was time consuming and difficult to assemble a skilled team consisting of one of more: surgeon, cardiologist, interventional radiologist, and transplant anesthetist. Small bowel transplantation is easier and safer with adequate central venous access, and we advocate liaison with an SBTx center at an early stage.
Central Venous Occlusion in the Hemodialysis Patient.
Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael
2016-11-01
Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicholson, Tony, E-mail: Tony.Nicholson@leedsth.nhs.uk; Ettles, Duncan; Robinson, Graham
2004-01-15
Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred withmore » carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device.« less
Davis, J; Surendran, T; Thompson, S; Corkey, C
2007-01-01
Incidence of type 1 diabetes mellitus is continuing to rise in children. The presentation of diabetic ketoacidosis (DKA) in children with newly diagnosed diabetes is significantly higher in those less than 5 years old. Critically ill patients admitted to Paediatric Intensive Care Units (PICU), would have a central venous line (CVL) inserted as part of their ongoing management. There are associations linking with the development of deep venous thrombosis (DVT) in DKA/CVL patients. An 18-month-old boy presented with a short history of polydypsia, polyuria and weight loss. The initial blood sugar was 27.0 mmol/L and a venous blood gas showed severe metabolic acidosis. He was diagnosed and treated for DKA. He was transferred to the regional PICU for further management. There, a central venous line (CVL) was inserted in his left femoral vein. This was removed on Day 4. Subsequently, he developed a swelling on his left leg, with significant discrepancy in leg circumference. Doppler ultrasound confirmed a deep venous thrombosis. Conclusion Diabetes has a propensity for hypercoagulability and DKA promotes a prothrombotic state. Retrospective studies have shown younger patients with DKA and a femoral CVL are at higher risk of developing DVT. A central femoral line should avoided in such patients. DVT prophylaxis and Doppler follow up should also be considered.
2009-08-25
both of which increase SV and CO (Figure 16). Specifically, circulating catecholamines decrease venous compliance and increase central venous pressure...t Inotropy t Central Venous Pressure , t Preload / t SV&CO 104 References 1. The Criteria Committee of the New York Heart Association...Science Degrees -Public Health Masters Degrees -Military Medical History -Public Health -Tropical Medicine & Hygiene Graduate Education Office
Pacific Pediatric Advanced Care Initiative
2010-10-01
cracked stopcock on the venous side c. Air introduced from medications infusing into the patient via a central venous line 6. After you have made sure...stopcock or pigtail. Withdraw volume to make venous pressures more negative History : Day 3 for a newborn infant with Group B sepsis. Eveything has...clinical laboratories, operating room, central supply, pharmacy, respiratory care, Neonatal Intensive Care Unit (NICU) nursing, Pediatric Intensive
[Prophylaxis of thrombosis induced by chemotherapy or central venous catheters].
Voog, Eric; Lazard, Eric; Juhel, Laurence
2007-02-01
Deep venous thrombosis and pulmonary embolism are well-recognized complications of cancer, especially in patients with a venous access device or receiving chemotherapy. The pathogenic mechanisms of thrombosis in cancer patients involve a complex interaction between the patient's tumor cells and hemostatic system. Chemotherapy and central venous catheters increase the risk of thromboembolism. Prophylactic treatment for these patients remains controversial. We conducted a systematic literature review using the Medline database and abstract books for meetings of the American Society of Clinical Oncology and the American Society of Hematology since 2000. Our search focused on clinical trials of primary prevention of venous catheter-related thrombosis or prevention of chemotherapy-related venous thromboembolism in cancer patients. Ten studies evaluating primary prevention of patients with central catheters were identified, and their results are contradictory. Currently only one study has examined prevention of chemotherapy-related venous thromboembolism, in women with metastatic breast cancer. Its results cannot be extrapolated to other tumors. Systematic prophylaxis cannot yet be recommended. In the near future we must improve our knowledge of the risk factors of these complications. Prophylaxis should be individualized for each patient. New anticoagulant drugs should be tested in cancer patients.
O'Neill, Rory; Morales, Javier; Jule, Michael
2012-05-01
Early goal-directed therapy (EGDT) has been shown to reduce mortality in patients with severe sepsis/septic shock, however, implementation of this protocol in the emergency department (ED) is sometimes difficult. We evaluated our sepsis protocol to determine which EGDT elements were more difficult to implement in our community-based ED. This was a non-concurrent cohort study of adult patients entered into a sepsis protocol at a single community hospital from July 2008 to March 2009. Charts were reviewed for the following process measures: a predefined crystalloid bolus, antibiotic administration, central venous catheter insertion, central venous pressure measurement, arterial line insertion, vasopressor utilization, central venous oxygen saturation measurement, and use of a standardized order set. We also compared the individual component adherence with survival to hospital discharge. A total of 98 patients presented over a 9-month period. Measures with the highest adherence were vasopressor administration (79%; 95% confidence interval [CI] 69-89%) and antibiotic use (78%; 95% CI 68-85%). Measures with the lowest adherence included arterial line placement (42%; 95% CI 32-52%), central venous pressure measurement (27%; 95% CI 18-36%), and central venous oxygen saturation measurement (15%; 95% CI 7-23%). Fifty-seven patients survived to hospital discharge (Mortality: 33%). The only element of EDGT to demonstrate a statistical significance in patients surviving to hospital discharge was the crystalloid bolus (79% vs. 46%) (respiratory rate [RR] = 1.76, 95% CI 1.11-2.58). In our community hospital, arterial line placement, central venous pressure measurement, and central venous oxygen saturation measurement were the most difficult elements of EGDT to implement. Patients who survived to hospital discharge were more likely to receive the crystalloid bolus. Copyright © 2012 Elsevier Inc. All rights reserved.
Clinical Investigation Program (Tripler Army Medical Center)
1991-10-01
temperatures - arterial and central venous blood pressure, relevant blood and urinary hormones, and urine flows will be measured via indwelling catheters...Analysis of central venous pressure recordings are not yet complete, but all experimentation is complete. 21 Detail Summary Sheet Prot No: llA91 Status... catheterized newborn rats are performed. Rats are instrumented with arterial, venous , and stomach catheters and a bladder cannula 3 to 7 days before
Ultrasound Guidance as a Rescue Technique for Peripheral Intravenous Cannulation
2006-09-14
painful, time consuming, and may result in arterial puncture, nerve damage, and paresthes ias.5 Other routes such as central venous or venous cut down...peripherally inserted central lines-PICCS), femoral catheterizations during cardiopulmonary resuscitation, and peripheral IV catheters in difficult...techniques for gaining venous access. What to do when peripheral intravenous catheterization is not possible. J Crit 11/n. 1993;8:435-442. 2. Nee PA
Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Chen, Ying-Tsung; Chi, Ching-Shiang
2005-01-01
To compare the right atrial pressure to the central venous pressures measured at different points in spontaneously breathing children and try to find a formula to estimate right atrial pressure by central venous pressure measurement. Fifty-one children, aged 5 +/- 4.7 years, who underwent right heart catheterization were studied. All patients were sedated and breathed naturally. The mean pressure was the electronic mean of nine heart beats calculated by Philips BC4000 digital angiographic system. Mean pressure of the right atrium was compared to those measured at the high superior vena cava (SVC), low SVC, high inferior vena cava (IVC) (T10-11), middle IVC (L1-2), low IVC (L3-4), and iliac vein (L5-S1). Mean pressures of central veins were significantly higher than that of the right atrium (all p<0.01). Adjusted central venous pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) had a good agreement with the right atrial pressure. Central venous pressures are significantly higher than the right atrial pressure in spontaneously breathing children. Adjusted pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) can accurately reflect the right atrial pressure.
Venous return curves obtained from graded series of valsalva maneuvers
NASA Technical Reports Server (NTRS)
Mastenbrook, S. M., Jr.
1974-01-01
The effects were studied of a graded series of valsalva-like maneuvers on the venous return, which was measured transcutaneously in the jugular vein of an anesthetized dog, with the animal serving as its own control. At each of five different levels of central venous pressure, the airway pressure which just stopped venous return during each series of maneuvers was determined. It was found that this end-point airway pressure is not a good estimator of the animal's resting central venous pressure prior to the simulated valsalva maneuver. It was further found that the measured change in right atrial pressure during a valsalva maneuver is less than the change in airway pressure during the same maneuver, instead of being equal, as had been expected. Relative venous return curves were constructed from the data obtained during the graded series of valsalva maneuvers.
[Port device central venous access in children with chronic renal disease--personal experience].
Szczepańska, Maria; Szprynger, Krystyna; Stoksik, Piotr; Morawiec-Knysak, Aurelia; Adamczyk, Piotr; Ziora, Katarzyna; Oswiecimska, Joanna
2006-01-01
The application of central venous lines in children has been widely accepted in the case of pediatric cancer treatment. This is of particular importance when the treatment must be continued during the long period of time. The indication to long-term application of central venous lines became significantly frequent within last years. They are necessary in the treatment of chronic pediatric patients, in whom the central venous line allows continuous access for medication, parenteral rehydration, nutrition and frequent blood sampling. In the current study authors present their experience in subcutaneous port devices application in children with kidney disease. The case history data obtained from 8 children were retrospectively analysed. In these children subcutaneous port devices were applied for mean 26.7 months (totally 9 port devices). The mean age at the time of implantation was 2.2 years, and the mean body weight--10.6 kg. Peripheral venous access in all children was bad. In one child during the time of implantation the hematoma of coli and chest was present. Infectious complications connected with implanted port device were not detected. Thrombotic complications were present in 6 children with chronic renal failure--in 5 the lumen of port device has been successfully recanalysed, in 3 cases even several times. In 1 child the thrombus on the tip of central venous line was detected. In 2 children the removal of port device was necessary because of breakage of venous line and in the second case because of port device thrombosis. Two children died with functioning port device. The cause of death was not connected with implanted port device. The application of subcutaneous port devices definitely improved the comfort of treatment but was significantly associated with thrombotic complications. Infectious complications were not detected as compared to hematological group of patients.
International Meeting on Simulation in Healthcare 2007
2007-03-01
Research Abstract : 32 Simulationbased Training in Ultrasound Assisted Central Venous Catheterization . Pamela Andreatta 1 , Rajani Mangrulkar 2...vascular access skill training for central venous catheterization , and basic and difficult airway management skill training with infant/pediatric/adult task...Office of Clinical Affairs, University of Michigan Health System Background: More than 5 million central venous catheters (CVCs) are inserted in the
Kotoda, Atsushi; Akimoto, Tetsu; Kato, Maki; Kanazawa, Hidenori; Nakata, Manabu; Sugase, Taro; Ogura, Manabu; Ito, Chiharu; Sugimoto, Hideharu; Muto, Shigeaki; Kusano, Eiji
2011-01-01
It is widely assumed that central venous stenosis (CVS) is most commonly associated with previous central venous catheterization among the chronic hemodialysis (HD) patients. We evaluated the validity of this assumption in this retrospective study. The clinical records from 2,856 consecutive HD patients with vascular access failure during a 5-year period were reviewed, and a total of 26 patients with symptomatic CVS were identified. Combined with radiological findings, their clinical characteristics were examined. Only seven patients had a history of internal jugular dialysis catheterization. Diagnostic multidetector row computed tomography angiography showed that 7 of the 19 patients with no history of catheterization had left innominate vein stenosis due to extrinsic compression between the sternum and arch vessels. These patients had a shorter period from the time of creation of the vascular access to the initial referral (9.2 ± 7.6 months) than the rest of the patients (35.5 ± 18.6 months, p = 0.0017). Our findings suggest that cases without a history of central venous catheterization may not be rare among the HD patients with symptomatic CVS. However, those still need to be confirm by larger prospective studies of overall chronic HD patients with symptomatic CVS.
Hacker, Robert I.; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F.
2012-01-01
Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters. PMID:23997555
Drews, Barbie; Macaluso, Michelle; Piper, Hannah; Channabasappa, Nandini
Pediatric patients with intestinal failure often require central venous catheters for extended periods of time for parenteral nutrition, blood sampling, and medication administration, increasing morbidity, mortality, and costs. In 2007, we reported a central line-associated bloodstream infection rate of 7.0 per 1,000 catheter line-days in our pediatric patients with intestinal failure. On the basis of this high rate of catheter-associated infections, we developed and implemented a central line care curriculum for patients/family caregivers and home health nurses. We aim to show with the implementation of patient/family caregiver and home health nurse standardized education, the central line-associated bloodstream infection rate can be significantly reduced and that this is sustainable. A retrospective review of 80 pediatric outpatients with intestinal failure and long-term central venous access was performed between January 1, 2009, and December 31, 2014. During this time period, the nursing department at Children's Medical Center of Dallas implemented a systematic central line care education program for patients and/or caregivers. The number of community-acquired central line-associated bloodstream infections during this time period was collected and compared with our previously reported data from 2005 to 2007 prior to the implementation of education program. With the implementation of standardized care guidelines and a central venous catheter care curriculum, the community-acquired rate decreased from 4.8 to 2.9 per 1,000 catheter-days in 80 patients with intestinal failure between January 1, 2009, and December 31, 2014 (p < .001). This was also a significant decrease compared with the initial central line-associated bloodstream infection rate of 7.0 per 1,000 central line days in 2007 (p < .001) prior to the development of the central venous catheter care curriculum. We have shown that the incidence of community-acquired central line-associated bloodstream infections in children with intestinal failure can be reduced through formal education of central venous catheter care to family members.
A concise history of central venous access.
Beheshti, Michael V
2011-12-01
Central venous access has become a mainstay of modern interventional radiology practice. Its history has paralleled and enabled many current medical therapies. This short overview provides an interesting historical perspective of these increasingly common interventional procedures. Copyright © 2011 Elsevier Inc. All rights reserved.
Lesimple, T; Béguec, J F; Levêque, J M
1998-10-31
Many treatments administered to cancer patients require venous access either via a peripheral vein or a larger central vein at the risk of local or systemic infection, thrombus formation or venous occlusion and dysfunction. Insertion of a central catheter is an invasive procedure which must be conducted under conditions of rigorous asepsia. Strict rules based on well-defined protocols must be applied throughout its use. Local or systemic infectious complications account for 18 to 25% of all nosocomial infections and are often related to colonisation of the puncture site by a Gram positive germ. In case of infection, ablation of the central catheter is not mandatory for diagnosis or antibiotic treatment. Reported at varying frequencies in the literature from 4 to 42%, thrombus formation is unpredictable and often difficult to diagnose. Anticoagulants or fibrolytic agents are indicated but it may also be necessary to withdraw the catheter. Displacement, rupture, obstruction and extravasation are frequent complications. Back flow must be checked in all venous accesses and free flow carefully verified. The access must remain patent throughout the period of use, guaranteed by a standard heparinization and rinsing protocol. This complications must not mask the important progress achieved with the use of central venous access for specific and symptomatic treatment in cancer patients.
Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.
Schallom, Marilyn E; Prentice, Donna; Sona, Carrie; Micek, Scott T; Skrupky, Lee P
2012-06-01
To compare heparin (3 mL, 10 units/mL) and 0.9% sodium chloride (NaCl, 10 mL) flush solutions with respect to central venous catheter lumen patency. Single-center, randomized, open label trial. Medical intensive care unit and Surgical/Burn/Trauma intensive care unit at Barnes-Jewish Hospital, St. Louis, MO. Three hundred forty-one patients with multilumen central venous catheters. Patients with at least one lumen with a minimum of two flushes were included in the analysis. Patients were randomly assigned within 12 hrs of central venous catheter insertion to receive either heparin or 0.9% sodium chloride flush. The primary outcome was lumen nonpatency. Secondary outcomes included the rates of loss of blood return, inability to infuse or flush through the lumen (flush failure), heparin-induced thrombocytopenia, and catheter-related blood stream infection. Assessment for patency was performed every 8 hrs in lumens without continuous infusions for the duration of catheter placement or discharge from intensive care unit. Three hundred twenty-six central venous catheters were studied yielding 709 lumens for analysis. The nonpatency rate was 3.8% in the heparin group (n = 314) and 6.3% in the 0.9% sodium chloride group (n = 395) (relative risk 1.66, 95% confidence interval 0.86-3.22, p = .136). The Kaplan-Meier analysis for time to first patency loss was not significantly different (log rank = 0.093) between groups. The rates of loss of blood return and flush failure were similar between the heparin and 0.9% sodium chloride groups. Pressure-injectable central venous catheters had significantly greater rates of nonpatency (10.6% vs. 4.3%, p = .001) and loss of blood return (37.0% vs. 18.8%, p <.001) compared to nonpressure-injectable catheters. The frequencies of heparin-induced thrombocytopenia and catheter-related blood stream infection were similar between groups. 0.9% sodium chloride and heparin flushing solutions have similar rates of lumen nonpatency. Given potential safety concerns with the use of heparin, 0.9% sodium chloride may be the preferred flushing solution for short-term use central venous catheter maintenance.
Habib, Ashraf S; Moul, Judd W; Polascik, Thomas J; Robertson, Cary N; Roche, Anthony M; White, William D; Hill, Stephen E; Nosnick, Israel; Gan, Tong J
2014-05-01
To compare acute normovolemic hemodilution versus low central venous pressure strategy versus conventional fluid management in reducing intraoperative estimated blood loss, hematocrit drop and need for blood transfusion in patients undergoing radical retropubic prostatectomy under general anesthesia. Patients undergoing radical retropubic prostatectomy under general anesthesia were randomized to conventional fluid management, acute normovolemic hemodilution or low central venous pressure (≤5 mmHg). Treatment effects on estimated blood loss and hematocrit change were tested in multivariable regression models accounting for surgeon, prostate size, and all two-way interactions. Ninety-two patients completed the study. Estimated blood loss (mean ± SD) was significantly lower with low central venous pressure (706 ± 362 ml) compared to acute normovolemic hemodilution (1103 ± 635 ml) and conventional (1051 ± 714 ml) groups (p = 0.0134). There was no difference between the groups in need for blood transfusion, or hematocrit drop from preoperative values. The multivariate model predicting estimated blood loss showed a significant effect of treatment (p = 0.0028) and prostate size (p = 0.0323), accounting for surgeon (p = 0.0013). In the model predicting hematocrit change, accounting for surgeon difference (p = 0.0037), the treatment effect depended on prostate size (p = 0.0007) with the slope of low central venous pressure differing from the other two groups. Hematocrit was predicted to drop more with increased prostate size in acute normovolemic hemodilution and conventional groups but not with low central venous pressure. Limitations include the inability to blind providers to group assignment, possible variability between providers in estimation of blood loss, and the relatively small sample size that was not powered to detect differences between the groups in need for blood transfusion. Maintaining low central venous pressure reduced estimated blood loss compared to conventional fluid management and acute normovolemic hemodilution in patients undergoing radical retropubic prostatectomy but there was no difference in allogeneic blood transfusion between the groups.
Central venous catheters: incidence and predictive factors of venous thrombosis.
Hammes, Mary; Desai, Amishi; Pasupneti, Shravani; Kress, John; Funaki, Brian; Watson, Sydeaka; Herlitz, Jean; Hines, Jane
2015-07-01
Central venous catheter access in an acute setting can be a challenge given underlying disease and risk for venous thrombosis. Peripherally inserted central venous catheters (PICCs) are commonly placed but limit sites for fistula creation in patients with chronic renal failure (CKD). The aim of this study is to determine the incidence of venous thrombosis from small bore internal jugular (SBIJ) and PICC line placement. This investigation identifies populations of patients who may not be ideal candidates for a PICC and highlights the importance of peripheral vein preservation in patients with renal failure. A venous Doppler ultrasound was performed at the time of SBIJ insertion and removal to evaluate for thrombosis in the internal jugular vein. Data was collected pre- and post-intervention to ascertain if increased vein preservation knowledge amongst the healthcare team led to less use of PICCs. Demographic factors were collected in the SBIJ and PICC groups and risk factor analysis was completed. 1,122 subjects had PICC placement and 23 had SBIJ placement. The incidence of thrombosis in the PICC group was 10%. One patient with an SBIJ had evidence of central vein thrombosis when the catheter was removed. Univariate and multivariate analysis demonstrated a history of transplant, and the indication of total parenteral nutrition was associated with thrombosis (p<0.001). The decrease in PICCs placed in patients with CKD 6 months before and after intervention was significant (p<0.05). There are subsets of patients ith high risk for thrombosis who may not be ideal candidates for a PICC.
Right Site, Wrong Route - Cannulating the Left Internal Jugular Vein.
Paik, Peter; Arukala, Sanjay K; Sule, Anupam A
2018-01-09
Central venous catheters are placed in approximately five million patients annually in the US. The preferred site of insertion is one with fewer risks and easier access. Although the right internal jugular vein is preferred, on occasion, the left internal jugular may have to be accessed. A patient was admitted for septic shock, cerebrovascular accident, and non-ST-segment elevation myocardial infarction. A central venous line was needed for antibiotic and vasopressor administration. Due to trauma from a fall to the right side and previously failed catheterization attempts at the left subclavian and femoral veins, the left internal jugular vein was accessed. On chest radiography for confirmation, the left internal jugular central venous catheter was seen projecting down the left paraspinal region. It did not take the expected course across the midline toward the right and into the superior vena cava (SVC). A review of a computed tomography (CT) scan of the chest with contrast done on a prior admission revealed a duplicated SVC on the left side that had not been reported in the original CT scan interpretation. A left-sided SVC is present in approximately 0.3% to 0.5% of the population, with 90% of these draining into the coronary sinus. During placements of central venous lines and pacemakers, irritation of the coronary sinus may result in hypotension, arrhythmia, myocardial ischemia, or cardiac arrest. A widened mediastinum can be an indication of a duplicated SVC. When attempting a left internal jugular vein central venous catheter placement, it is important to be aware of venous anomalies in order to prevent complications.
Distension of central great vein decreases sympathetic outflow in humans
Cui, Jian; Gao, Zhaohui; Blaha, Cheryl; Herr, Michael D.; Mast, Jessica
2013-01-01
Classic canine studies suggest that central great vein distension evokes an autonomic reflex tachycardia (Bainbridge reflex). It is unclear whether central venous distension in humans is a necessary and sufficient stimulus to evoke a reflex increase in heart rate (HR), blood pressure (BP), and muscle sympathetic nerve activity (MSNA). Prior work from our laboratory suggests that limb venous distension evokes a reflex increase in BP and MSNA in humans. We hypothesized that in humans, compared with the limb venous distension, inferior vena cava (IVC) distension would evoke a less prominent increase in HR and MSNA. IVC distension (monitored with ultrasonography) was induced by two methods: 1) head-down tilt (HDT, N = 13); and 2) lower-body positive pressure (LBPP, N = 10). Two minutes of HDT induced IVC distension (Δ2.6 ± 0.2 mm, P < 0.001, ∼27% in cross-sectional area), slightly increased mean BP (Δ2.3 ± 0.7 mmHg, P = 0.005), decreased MSNA (Δ5.2 ± 0.8 bursts/min, P < 0.001, N = 10), and did not alter HR (P = 0.37). LBPP induced similar IVC distension, increased BP (Δ2.0 ± 0.7 mmHg, P < 0.01), and did not alter HR (P = 0.34). Thus central venous distension leads to a rapid increase in BP and a subsequent fall in MSNA. Central venous distension does not evoke either bradycardia or tachycardia in humans. The absence of a baroreflex-mediated bradycardia suggests that the Bainbridge reflex is engaged. Clearly, this reflex differs from the powerful sympathoexcitation peripheral venous distension reflex described in humans. PMID:23729210
Distension of central great vein decreases sympathetic outflow in humans.
Cui, Jian; Gao, Zhaohui; Blaha, Cheryl; Herr, Michael D; Mast, Jessica; Sinoway, Lawrence I
2013-08-01
Classic canine studies suggest that central great vein distension evokes an autonomic reflex tachycardia (Bainbridge reflex). It is unclear whether central venous distension in humans is a necessary and sufficient stimulus to evoke a reflex increase in heart rate (HR), blood pressure (BP), and muscle sympathetic nerve activity (MSNA). Prior work from our laboratory suggests that limb venous distension evokes a reflex increase in BP and MSNA in humans. We hypothesized that in humans, compared with the limb venous distension, inferior vena cava (IVC) distension would evoke a less prominent increase in HR and MSNA. IVC distension (monitored with ultrasonography) was induced by two methods: 1) head-down tilt (HDT, N = 13); and 2) lower-body positive pressure (LBPP, N = 10). Two minutes of HDT induced IVC distension (Δ2.6 ± 0.2 mm, P < 0.001, ~27% in cross-sectional area), slightly increased mean BP (Δ2.3 ± 0.7 mmHg, P = 0.005), decreased MSNA (Δ5.2 ± 0.8 bursts/min, P < 0.001, N = 10), and did not alter HR (P = 0.37). LBPP induced similar IVC distension, increased BP (Δ2.0 ± 0.7 mmHg, P < 0.01), and did not alter HR (P = 0.34). Thus central venous distension leads to a rapid increase in BP and a subsequent fall in MSNA. Central venous distension does not evoke either bradycardia or tachycardia in humans. The absence of a baroreflex-mediated bradycardia suggests that the Bainbridge reflex is engaged. Clearly, this reflex differs from the powerful sympathoexcitation peripheral venous distension reflex described in humans.
Wang, Ting-Yao; Lee, Kuan-Der; Chen, Ping-Tsung; Chen, Min-Chi; Chen, Yi-Yang; Huang, Cih-En; Kuan, Feng-Che; Chen, Chih-Cheng; Lu, Chang Hsien
2015-11-01
Cytotoxic chemotherapy via central venous access ports is an important part of the standard treatment for most cancers, but it is accompanied with the risk of infections. This study aimed to analyze the incidence and risk factors for central venous access port-related infection (CPI) among Chinese patients receiving cytotoxic chemotherapy. Between January 1, 2002 and December 31, 2005 a total of 1391 cancer patients with 1449 totally implantable central venous access ports were evaluated. The log-rank test and Cox proportional hazards model were used for the analyses of risk factors. The overall CPI incidence rate was 0.21 per 1000 catheter-days. Hematological malignancies and head and neck cancer were associated with an increased risk of CPI (hazard ratio 4.00 and 4.11, respectively, both p < 0.001) and less infection-free catheter longevity (p < 0.001) compared with other cancer types. Chemotherapy in an adjuvant setting was associated with a lower risk of infection than for patients in a nonadjuvant setting (p < 0.001). The most common pathogens isolated from CPI were Pseudomonas aeruginosa and Candida. Infection remains to be a challenging issue for totally implantable central venous ports. Implementation of an insertion bundle for the prevention of central line-associated bloodstream infections is warranted, especially for those patients with hematological and head and neck cancers, as well as for patients receiving chemotherapy in the metastatic settings. Copyright © 2015. Published by Elsevier B.V.
[Delayed (tension) pneumothorax after placement of a central venous catheter].
Tan, E C; van der Vliet, J A
1999-09-11
Laborious attempts at introducing a central venous catheter for parenteral nutrition in two women, aged 36 and 62 years, were followed by shortness of breath after 32 and 10 hours, respectively. This symptom was due to a (tension) pneumothorax not visible on earlier roentgenograms. Thoracic drainage led to recovery. In all patients with a central venous catheter an undetected delayed pneumothorax can be present. Urgent chest X-ray examination should be performed in all patients with acute respiratory symptoms. Patients undergoing elective intubation with positive pressure breathing should be examined carefully, since they are at risk of developing a late (tension) pneumothorax.
Prevention of venous pain and phlebitis caused by epirubicin hydrochloride.
Sugimoto, Masakazu; Matsui, Masateru; Harada, Masanori; Yamauchi, Yumiko; Moriyama, Nao; Andou, Kanae; Yamamoto, Makoto; Yamaoka, Hisayo; Ono, Chiemi; Ishikawa, Mami; Kamo, Nobuyuki; Ikeda, Tadashi; Yamaoka, Keiko
2009-06-01
Many patients complain of venous pain or develop phlebitis following treatment with epirubicin hydrochloride(EPI). To ensure effective and safe treatment with this drug, it is essential to deal with the adverse events associated with it appropriately. At our hospital, EPI was previously administered by drip infusion(diluted with 50mL of physiological saline)over 15 minutes after pretreatment(EPI main route). With this method of treatment, venous pain and phlebitis developed in 14 of 15 cases. In 3 of these 14 cases, the regimen was modified. Following this experience, EPI administration was switched to drip infusion from the fully-opened side tube used for pretreatment(EPI sub-route). Switching to this route resulted in a sharp decrease in the incidence of venous pain and phlebitis, to only 1 of 15 cases. Stimulation of vascular tunica intima by EPI has been considered a factor principally responsible for the venous pain and phlebitis seen after EPI therapy. To prevent these adverse reactions, it is necessary to modify the method of administration so that strong or long-term exposure of blood vessels to EPI can be reduced. The results of this study suggest that the EPI sub-route we devised is useful in achieving this goal.
Alternating versus synchronous ventilation of left and right lungs in piglets.
Versprille, A; Hrachovina, V; Jansen, J R
1995-12-01
We tested whether alternating ventilation (AV) of each lung (i.e. with a phase difference of half a ventilatory cycle) would decrease central venous pressure and so increase cardiac output when compared with simultaneous ventilation (SV) of both lungs. If, during AV, the inflated lung expands partly via compression of the opposite lung, mean lung volume will be smaller during AV than SV. As a consequence, mean intrathoracic pressure (as cited in the literature), and therefore, central venous pressure will be smaller. The experiments were performed in seven anaesthetized and paralyzed piglets using a double-piston ventilator. Minute ventilation was the same during AV and SV. Starting at SV, we alternated three times between AV and SV for periods of 10 min. During AV, central venous pressure was decreased by 0.7 mmHg and cardiac output was increased by 10 +/- 4.4% (mean, +/-SD) compared with SV. AV also resulted in increased arterial pressure. During one-sided inflation with closed outlet of the opposite lung, a pressure rise occurred in the opposite lung, indicating compression. The higher cardiac output during AV than SV can be explained by the fact that central venous pressure is lower during AV. This lower central venous pressure is very probably due to the lower mean intrathoracic pressure caused by compression of the opposite lung during unilateral inflation.
Kwon, Hyun-Jung; Jeong, Young-Il; Jun, In-Gu; Moon, Young-Jin; Lee, Yu-Mi
2018-01-01
Abstract Subclavian central venous catheterization is a common procedure for which misplacement of the central venous catheter (CVC) is a frequent complication that can potentially be fatal. The carina is located in the mid-zone of the superior vena cava (SVC) and is considered a reliable landmark for CVC placement in chest radiographs. The C-length, defined as the distance from the edge of the right transverse process of the first thoracic spine to the carina, can be measured in posteroanterior chest radiographs using a picture archiving and communication system. To evaluate the placement of the tip of the CVC in subclavian central venous catheterizations using the C-length, we reviewed the medical records and chest radiographs of 122 adult patients in whom CVC catheterization was performed (from January 2012 to December 2014) via the right subclavian vein using the C-length. The tips of all subclavian CVCs were placed in the SVC using the C-length. No subclavian CVC entered the right atrium. Tip placement was not affected by demographic characteristics such as age, sex, height, weight, and body mass index. The evidence indicates that the C-length on chest radiographs can be used to determine the available insertion length and place the right subclavian CVC tip into the SVC. PMID:29480861
Ultrasound guidance for internal jugular vein cannulation: Continuing Professional Development.
Ayoub, Christian; Lavallée, Catherine; Denault, André
2010-05-01
The objective of this continuing professional development module is to describe the role of ultrasound for central venous catheterization and to specify its benefits and limitations. Although ultrasound techniques are useful for all central venous access sites, the focus of this module is on the internal jugular vein approach. In recent years, several studies were published on the benefits of ultrasound use for central venous catheterization. This technique has evolved rapidly due to improvements in the equipment and technology available. Ultrasound helps to detect the anatomical variants of the internal jugular vein. The typical anterolateral position of the internal jugular vein with respect to the carotid is found in only 9-92% of cases. Ultrasound guidance reduces the rate of mechanical, infectious, and thrombotic complications by 57%, and it also reduces the failure rate by 86%. Cost-benefit analyses show that the cost of ultrasound equipment is compensated by the decrease in the expenses associated with the treatment of complications. In this article, we will review the history of ultrasound guidance as well as the reasons that account for its superiority over the classical anatomical landmark technique. We will describe the equipment needed for central venous catheterization as well as the various methods to visualize with ultrasound. To improve patient safety, we recommend the use of ultrasound for central venous catheterization using the internal jugular approach.
Santos-Martínez, Luis Efren; Guevara-Carrasco, Marlene; Naranjo-Ricoy, Guillermo; Baranda-Tovar, Francisco Martín; Moreno-Ruíz, Luis Antonio; Herrera-Velázquez, Marco Antonio; Magaña-Serrano, José Antonio; Valencia-Sánchez, Jesús Salvador; Calderón-Abbo, Moisés Cutiel
2014-01-01
The concordance between the parameters of arterial and central venous blood gases has not been defined yet. We studied the concordance between both parameters in post-surgical myocardial revascularization patients in stable condition. Consecutive subjects were studied in a cross-sectional design. The position of the central venous catheter was performed and simultaneously we obtained arterial and central venous blood samples prior to discharge from the intensive care unit. Data are expressed according to Bland-Altman statistical method and the intraclass correlation coefficient. Statistical result was accepted at P<.05. Two hundred and six samples were studied of 103 post-surgical patients, pH and lactate had a mean difference (limits of agreement) 0.029±0.048 (-0018, 0.077) and -0.12±0.22 (-0.57, 0.33) respectively. The magnitude of the intraclass correlation coefficient was 0.904 and 0.943 respectively. The values related to oxygen pressure were 27.86±6.08 (15.9, 39.8) and oxygen saturation 33.02±6.13 (21, 45), with magnitude of 0.258 and 0.418 respectively. The best matching parameters between arterial and central venous blood samples were pH and lactate. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.
Prospective Durability Testing of a Vascular Access Phantom
2010-09-01
ultrasound guidance when obtaining central venous access.19,20 The increasing use of ultrasound guidance for vascular access has created an educational...with difficult intravenous access. Ann Emerg Med. 2005;46:456-61. 7. Gallieni M, Cozzolino M. Uncomplicated central vein catheterization of high risk...al. Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: The third sonography
Central line infections - hospitals
... infection; CVC - infection; Central venous device - infection; Infection control - central line infection; Nosocomial infection - central line infection; Hospital acquired infection - central line infection; Patient safety - central ...
Physiologic Pressure and Flow Changes During Parabolic Flight (Pilot Study)
NASA Technical Reports Server (NTRS)
Pantalos, George; Sharp, M. Keith; Mathias, John R.; Hargens, Alan R.; Watenpaugh, Donald E.; Buckey, Jay C.
1999-01-01
The objective of this study was to obtain measurement of cutaneous tissue perfusion central and peripheral venous pressure, and esophageal and abdominal pressure in human test subjects during parabolic flight. Hemodynamic data recorded during SLS-I and SLS-2 missions have resulted in the paradoxical finding of increased cardiac stroke volume in the presence of a decreased central venous pressure (CVP) following entry in weightlessness. The investigators have proposed that in the absence of gravity, acceleration-induced peripheral vascular compression is relieved, increasing peripheral vascular capacity and flow while reducing central and peripheral venous pressure, This pilot study seeks to measure blood pressure and flow in human test subjects during parabolic flight for different postures.
Pinch-off syndrome: transection of implantable central venous access device.
Sugimoto, Takuya; Nagata, Hiroshi; Hayashi, Ken; Kano, Nobuyasu
2012-11-30
As the population of people with cancer increases so does the number of patients who take chemotherapy. Majority of them are administered parentally continuously. Implantable central venous catheter device is a good choice for those patients; however, severe complication would occur concerning the devices. Pinch-off syndrome is one of the most severe complications. The authors report a severe case of pinch-off syndrome. The patient with the implantable central venous device could not take chemotherapy because the device occluded. Further examination revealed the transection of the catheter. The transected fragment of the catheter in the heart was successfully removed by using a loop snare placed through the right femoral vein.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ni, Nina, E-mail: nina.ni@yale.edu; Mojibian, Hamid; Pollak, Jeffrey
To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A {chi}{sup 2} test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venousmore » stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P < 0.01, {chi}{sup 2} test). Time to central venous stenosis development was approximately 3 years in both groups and not significantly different (1371 and 1010 days, P = 0.20). A total of 25.2% of patients in the balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P < 0.01, {chi}{sup 2} test). In conclusions, there is a possible association between percutaneous transluminal angioplasty balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.« less
Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S
2000-11-01
In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.
Circulatory failure during severe hyperthermia in dog.
Miki, K; Morimoto, T; Nose, H; Itoh, T; Yamada, S
1983-01-01
The effect of acute hyperthermia on circulatory function was studied in 6 mongrel dogs. At a core temperature of about 40 degrees C, central venous pressure and stroke volume were maintained at almost normal level. Cardiac output significantly increased (26 ml/(kg . min)) while systemic vascular resistance significantly decreased (1.2 mmHg . sec/ml). In addition, significant decrease in vascular compliance by 40% was observed. When body temperature was raised further (severe hyperthermia), an abrupt fall of arterial pressure was observed at the rectal temperature of about 41-42 degrees C. Concomitant decreases in central venous pressure (3 mmHg), stroke volume (2.1 ml/beat) and cardiac output (29 ml/(kg . min)) were observed while heart rate increased (48 beats/min). These results suggest that the decrease in cardiac output during severe hyperthermia is due to the fall of central venous pressure, and the fall was attributed to the increase in unstressed vascular volume of systemic circulation due to the heat-induced cutaneous vasodilation. The observed decrease in systemic vascular compliance is considered to have a significant role in the maintenance of central venous pressure under hyperthermia.
Decreasing dialysis catheter rates by creating a multidisciplinary dialysis access program.
Rosenberry, Patricia M; Niederhaus, Silke V; Schweitzer, Eugene J; Leeser, David B
2018-03-01
Centers for Medicare and Medicaid Services have determined that chronic dialysis units should have <12% of their patients utilizing central venous catheters for hemodialysis treatments. On the Eastern Shore of Maryland, the central venous catheter rates in the dialysis units averaged >45%. A multidisciplinary program was established with goals of decreasing catheter rates in order to decrease central line-associated bloodstream infections, decrease mortality associated with central line-associated bloodstream infection, decrease hospital days, and provide savings to the healthcare system. We collected the catheter rates within three dialysis centers served over a 5-year period. Using published data surrounding the incidence and related costs of central line-associated bloodstream infection and mortality per catheter day, the number of central line-associated bloodstream infection events, the costs, and the related mortality could be determined prior to and after the initiation of the dialysis access program. An organized dialysis access program resulted in a 82% decrease in the number of central venous catheter days which lead to a concurrent reduction in central line-associated bloodstream infection and deaths. As a result of creating an access program, central venous catheter rates decreased from an average rate of 45% to 8%. The cost savings related to the program was calculated to be over US$5 million. The decrease in the number of mortalities is estimated to be between 13 and 27 patients. We conclude that a formalized access program decreases catheter rates, central line-associated bloodstream infection, and the resultant hospitalizations, mortality, and costs. Areas with high hemodialysis catheter rates should develop access programs to better serve their patient population.
2013-01-01
Background The role of the extracranial venous system in the pathology of central nervous system (CNS) disorders and aging is largely unknown. It is acknowledged that the development of the venous system is subject to many variations and that these variations do not necessarily represent pathological findings. The idea has been changing with regards to the extracranial venous system. Discussion A range of extracranial venous abnormalities have recently been reported, which could be classified as structural/morphological, hemodynamic/functional and those determined only by the composite criteria and use of multimodal imaging. The presence of these abnormalities usually disrupts normal blood flow and is associated with the development of prominent collateral circulation. The etiology of these abnormalities may be related to embryologic developmental arrest, aging or other comorbidities. Several CNS disorders have been linked to the presence and severity of jugular venous reflux. Another composite criteria-based vascular condition named chronic cerebrospinal venous insufficiency (CCSVI) was recently introduced. CCSVI is characterized by abnormalities of the main extracranial cerebrospinal venous outflow routes that may interfere with normal venous outflow. Summary Additional research is needed to better define the role of the extracranial venous system in relation to CNS disorders and aging. The use of endovascular treatment for the correction of these extracranial venous abnormalities should be discouraged, until potential benefit is demonstrated in properly-designed, blinded, randomized and controlled clinical trials. Please see related editorial: http://www.biomedcentral.com/1741-7015/11/259. PMID:24344742
The Formation and Erosion History of Mt. Sharp
NASA Technical Reports Server (NTRS)
Allen, Carlton C.; Dapremont, Angela M.
2014-01-01
The Curiosity rover is exploring 155 km diameter Gale crater and Mt. Sharp, Gale's 5 km high central mound (Fig. 1). This study addresses the formation and erosion history of Mt. Sharp. Gale lies on the topographic dichotomy between the southern highlands and the northern plains - a drop of over 2 km [1,2]. Altitude differences between the north and south rim reflect this regional slope, as do altitude differences between the deep annulus north of Mt. Sharp and the southern crater floor. Orbiter and rover images demonstrate that most exposed areas on Mt. Sharp consist of thin, sub-parallel units interpreted as sedimentary layers [3]. Gale is typical of the 50 large martian craters that have been totally or partially filled with such layers [4,5]. In many craters these sediments have been deeply eroded. Central Peak and Peak Ring: The highest point on Mt. Sharp, near the crater's center, is interpreted as a central peak [6]. The peak has a massive lower portion and a thin, smooth capping deposit (Fig. 2). Gale's size is transitional between martian craters with single central peaks and craters with peak rings approximately half the crater's diameter [2,6]. The boundaries of Mt. Sharp, as well as an arc of hills to the southeast of the mountain, closely match a circle approximately 80 km in diameter (Fig. 3). This morphology suggests that the Gale impact may have formed both a central peak and a partial peak ring, which is covered by the sediments of Mt. Sharp in the north and possibly exposed in the arc of eroded hills in the southeast quadrant (Figs. 3,4).
Noritomi, Danilo Teixeira; Zigaib, Rogério; Ranzani, Otavio T; Teich, Vanessa
2016-01-01
To evaluate the cost-effectiveness, from the funding body's point of view, of real-time ultrasound-guided central venous catheter insertion compared to the traditional method, which is based on the external anatomical landmark technique. A theoretical simulation based on international literature data was applied to the Brazilian context, i.e., the Unified Health System (Sistema Único de Saúde - SUS). A decision tree was constructed that showed the two central venous catheter insertion techniques: real-time ultrasonography versus external anatomical landmarks. The probabilities of failure and complications were extracted from a search on the PubMed and Embase databases, and values associated with the procedure and with complications were taken from market research and the Department of Information Technology of the Unified Health System (DATASUS). Each central venous catheter insertion alternative had a cost that could be calculated by following each of the possible paths on the decision tree. The incremental cost-effectiveness ratio was calculated by dividing the mean incremental cost of real-time ultrasound compared to the external anatomical landmark technique by the mean incremental benefit, in terms of avoided complications. When considering the incorporation of real-time ultrasound and the concomitant lower cost due to the reduced number of complications, the decision tree revealed a final mean cost for the external anatomical landmark technique of 262.27 Brazilian reals (R$) and for real-time ultrasound of R$187.94. The final incremental cost of the real-time ultrasound-guided technique was -R$74.33 per central venous catheter. The incremental cost-effectiveness ratio was -R$2,494.34 due to the pneumothorax avoided. Real-time ultrasound-guided central venous catheter insertion was associated with decreased failure and complication rates and hypothetically reduced costs from the view of the funding body, which in this case was the SUS.
Creating and evaluating a data-driven curriculum for central venous catheter placement.
Duncan, James R; Henderson, Katherine; Street, Mandie; Richmond, Amy; Klingensmith, Mary; Beta, Elio; Vannucci, Andrea; Murray, David
2010-09-01
Central venous catheter placement is a common procedure with a high incidence of error. Other fields requiring high reliability have used Failure Mode and Effects Analysis (FMEA) to prioritize quality and safety improvement efforts. To use FMEA in the development of a formal, standardized curriculum for central venous catheter training. We surveyed interns regarding their prior experience with central venous catheter placement. A multidisciplinary team used FMEA to identify high-priority failure modes and to develop online and hands-on training modules to decrease the frequency, diminish the severity, and improve the early detection of these failure modes. We required new interns to complete the modules and tracked their progress using multiple assessments. Survey results showed new interns had little prior experience with central venous catheter placement. Using FMEA, we created a curriculum that focused on planning and execution skills and identified 3 priority topics: (1) retained guidewires, which led to training on handling catheters and guidewires; (2) improved needle access, which prompted the development of an ultrasound training module; and (3) catheter-associated bloodstream infections, which were addressed through training on maximum sterile barriers. Each module included assessments that measured progress toward recognition and avoidance of common failure modes. Since introducing this curriculum, the number of retained guidewires has fallen more than 4-fold. Rates of catheter-associated infections have not yet declined, and it will take time before ultrasound training will have a measurable effect. The FMEA provided a process for curriculum development. Precise definitions of failure modes for retained guidewires facilitated development of a curriculum that contributed to a dramatic decrease in the frequency of this complication. Although infections and access complications have not yet declined, failure mode identification, curriculum development, and monitored implementation show substantial promise for improving patient safety during placement of central venous catheters.
NASA Technical Reports Server (NTRS)
Allen, Carlton C.
2015-01-01
The Curiosity rover is exploring 155 km diameter Gale crater and Mt. Sharp, Gale's high central mound. This study addresses the central peak and proposed peak ring, and their influence on the overall morphology of the mountain.
Determination of Medical Task Times in an Emergency Center Setting
1990-08-01
supraclavicular central venous line, "Wound expl." signifies wound exploration, and "thoracostomy" refers to tube thoracostomy. The task time for chest...bore line is needed for aggressive fluid resuscitation, or whenever monitoring of central venous pressure as a reflection of available blood volume...of newly annexed city territory. Most ALS responses in the central city are made within 4 min of receipt of calls. There were 68,000 EMS transports
Sandblom, Erik; Axelsson, Michael; Farrell, Anthony P
2006-11-01
Subambient central venous pressure (Pven) and modulation of venous return through cardiac suction (vis a fronte) characterizes the venous circulation in sharks. Venous capacitance was estimated in the dogfish Squalus acanthias by measuring the mean circulatory filling pressure (MCFP) during transient occlusion of cardiac outflow. We tested the hypothesis that venous return and cardiac preload can be altered additionally through adrenergic changes of venous capacitance. The experiments involved the surgical opening of the pericardium to place a perivascular occluder around the conus arteriosus. Another control group was identically instrumented, but lacked the occluder, and was subjected to the same pharmacological protocol to evaluate how pericardioectomy affected cardiovascular status. Routine Pven was negative (-0.08+/-0.02 kPa) in control fish but positive (0.09+/-0.01 kPa) in the pericardioectomized group. Injections of 5 microg/kg body mass (Mb) of epinephrine and phenylephrine (100 microg/kg Mb) increased Pven and MCFP, whereas isoproterenol (1 microg/kg Mb) decreased both variables. Thus, constriction and relaxation of the venous vasculature were mediated through the respective stimulation of alpha- and beta-adrenergic receptors. Alpha-adrenergic blockade with prazosin (1 mg/kg Mb) attenuated the responses to phenylephrine and decreased resting Pven in pericardioectomized animals. Our results provide convincing evidence for adrenergic control of the venous vasculature in elasmobranchs, although the pericardium is clearly an important component in the modulation of venous function. Thus active changes in venous capacitance have previously been underestimated as an important means of modulating venous return and cardiac performance in this group.
Endovascular Treatment of Veno-Occlusive Behcet's Disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tekbas, Guven, E-mail: drgtekbas@gmail.com; Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Gur, Serkan, E-mail: mserkangur@yahoo.com
Purpose: To retrospectively evaluate the outcome of endovascular treatments for patients with chronic veno-occlusive disease in different vascular beds secondary to Behcet's disease (BD). There are few case reports on the subject, and this is the largest study to date. Materials and Methods: From January 2001 through October 2009, chronic venous occlusions were treated in 10 patients (all male [age range 18-76 years]) with BD using percutaneous transluminal angioplasty and/or stent placement. All patients were symptomatic and had chronic iliofemoral deep venous thrombosis (DVT; n = 5), central venous occlusion (n = 3), or Budd-Chiari syndrome (BCS; n = 2).more » All patients met criteria of the International Study Group on Behcet's Disease. Results: Two of five patients with DVT had unsuccessful recanalization attempts. Three patients had successful recanalization with stent placement. All three veins were occluded within 1 month with unsuccessful reinterventions. Three patients with chronic central venous occlusion had successful recanalization with percutaneous transluminal angioplasty (n = 1) and stent placement (n = 2). Two patients had reocclusion with successful reintervention. Two BCS patients had successful treatment with stent placements. Overall technical success was 69%, and no procedural complications were encountered. None of the patients with chronic DVT had patent veins; however, all patients with central venous occlusion or BCS had patent veins on color Doppler ultrasonography at follow-up ranging from 3 to 48 months after intervention. Conclusion: Endovenous treatment for chronic iliofemoral DVT due to BD had a poor outcome. However, long-term outcome after endovenous treatment for upper-extremity central venous occlusion and BCS syndrome was good.« less
Part versus Whole: A Randomized Trial of Central Venous Catheterization Education
ERIC Educational Resources Information Center
Chan, Angela; Singh, Sunita; Dubrowski, Adam; Pratt, Daniel D.; Zalunardo, Nadia; Nair, Parvarthy; McLaughlin, Kevin; Ma, Irene W. Y.
2015-01-01
Central venous catheterization (CVC) is a complex but commonly performed procedure. How best to teach this complex skill has not been clearly delineated. We conducted a randomized trial of the effects of two types of teaching of CVC on skill acquisition and retention. We randomly assigned novice internal medicine residents to learning CVC in-part…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kundu, Sanjoy, E-mail: sanjoy_kundu40@hotmail.com; Modabber, Milad; You, John M.
2011-10-15
Purpose: To assess the safety and effectiveness of a polytetrafluoroethylene (PTFE) encapsulated nitinol stents (Bard Peripheral Vascular, Tempe, AZ) for treatment of hemodialysis-related central venous occlusions. Materials and Methods: Study design was a single-center nonrandomized retrospective cohort of patients from May 2004 to August 2009 for a total of 64 months. There were 14 patients (mean age 60 years, range 50-83 years; 13 male, 1 female). All patients had autogenous fistulas. All 14 patients had central venous occlusions and presented with clinical symptoms of the following: extremity swelling (14%, 2 of 14), extremity and face swelling (72%, 10 of 14),more » and face swelling/edema (14%, 2 of 14). There was evidence of access dysfunction with decreased access flow in 36% (5 of 14) patients. There were prior interventions or previous line placement at the site of the central venous lesion in all 14 patients. Results were assessed by recurrence of clinical symptoms and function of the access circuit (National Kidney Foundation recommended criteria). Results: Sixteen consecutive straight stent grafts were implanted in 14 patients. Average treated lesion length was 5.0 cm (range, 0.9-7 cm). All 14 patients had complete central venous occlusion (100% stenosis). The central venous occlusions were located as follows: right subclavian and brachiocephalic vein (21%, 3 of 14), right brachiocephalic vein (36%, 5 of 14), left brachiocephalic vein (36%, 5 of 14), and bilateral brachiocephalic vein (7%, 1 of 14). A total of 16 PTFE stent grafts were placed. Ten- or 12-mm-diameter PTFE stent grafts were placed. The average stent length was 6.1 cm (range, 4-8 cm). Technical (deployment), anatomic (<30% residual stenosis), clinical (resolution of symptoms), and hemodynamic (resolution of access dysfunction) success were 100%. At 3, 6, and 9 months, primary patency of the treated area and access circuit were 100% (14 of 14). Conclusions: This PTFE encapsulated stent graft demonstrates encouraging intermediate-term patency results for central vein occlusions. Further prospective studies with long-term assessment and larger patient populations will be required.« less
Camkiran Firat, Aynur; Zeyneloglu, Pinar; Ozkan, Murat; Pirat, Arash
2016-09-01
To compare internal jugular vein and subclavian vein access for central venous catheterization in terms of success rate and complications. A 1:1 randomized controlled trial. Baskent University Medical Center. Pediatric patients scheduled for cardiac surgery. Two hundred and eighty children undergoing central venous catheterization were randomly allocated to the internal jugular vein or subclavian vein group during a period of 18 months. The primary outcome was the first-attempt success rate of central venous catheterization through either approach. The secondary outcomes were the rates of infectious and mechanical complications. The central venous catheterization success rate at the first attempt was not significantly different between the subclavian vein (69%) and internal jugular vein (64%) groups (p = 0.448). However, the overall success rate was significantly higher through the subclavian vein (91%) than the internal jugular vein (82%) (p = 0.037). The overall frequency of mechanical complications was not significantly different between the internal jugular vein (25%) and subclavian vein (31%) (p = 0.456). However, the rate of arterial puncture was significantly higher with internal jugular vein (8% vs 2%; p = 0.03) and that of catheter malposition was significantly higher with subclavian vein (17% vs 1%; p < 0.001). The rates per 1,000 catheter days for both positive catheter-tip cultures (26.1% vs 3.6%; p < 0.001) and central-line bloodstream infection (6.9 vs 0; p < 0.001) were significantly higher with internal jugular vein. There were no significant differences between the groups in the length of ICU and hospital stays or in-hospital mortality rates (p > 0.05 for all). Central venous catheterization through the internal jugular vein and subclavian vein was not significantly different in terms of success at the first attempt. Although the types of mechanical complications were different, the overall rate was similar between internal jugular vein and subclavian vein access. The risk of infectious complications was significantly higher with internal jugular vein access.
Linnemann, Birgit; Lindhoff-Last, Edelgard
2012-09-01
An adequate vascular access is of importance for the treatment of patients with cancer and complex illnesses in the intensive, perioperative or palliative care setting. Deep vein thrombosis and thrombotic occlusion are the most common complications attributed to central venous catheters in short-term and, especially, in long-term use. In this review we will focus on the risk factors, management and prevention strategies of catheter-related thrombosis and occlusion. Due to the lack of randomised controlled trials, there is still controversy about the optimal treatment of catheter-related thrombotic complications, and therapy has been widely adopted using the evidence concerning lower extremity deep vein thrombosis. Given the increasing use of central venous catheters in patients that require long-term intravenous therapy, the problem of upper extremity deep venous thrombosis can be expected to increase in the future. We provide data for establishing a more uniform strategy for preventing, diagnosing and treating catheter-related thrombotic complications.
[Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].
Conz, P A; Malagoli, A; Normanno, M; Munaro, D
2007-01-01
A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.
Wetzel, Lindsay R; Patel, Priyesh R; Pesa, Nicholas L
2017-07-01
An elderly male presented for emergent repair of a ruptured abdominal aortic aneurysm. For anticipated volume resuscitation, vasopressor administration, and hemodynamic monitoring, a large-bore central venous catheter was placed in the left internal jugular vein under ultrasound guidance before surgical incision. Initially, there were no readily apparent signs of venous perforation. However, a massive left hemothorax developed because of perforation of the brachiocephalic vein and violation of the pleural space. This case report discusses both prevention and management of such a complication.
Long-term venous access using a subcutaneous implantable drug delivery system.
Soo, K. C.; Davidson, T. I.; Selby, P.; Westbury, G.
1985-01-01
To facilitate long-term venous access in patients receiving chemotherapy, a subcutaneous totally implantable system (Port-a-Cath, Phamacia) has been used in 14 patients. The method of implantation and the advantages over conventional central venous catheters are discussed. The expense of the system necessitates careful patient selection. PMID:4037644
Central venous catheter-related thrombosis in senile male patients: New risk factors and predictors.
Liu, Gao; Fu, Zhi-Qing; Zhu, Ping; Li, Shi-Jun
2015-06-01
Central venous catheterization (CVC)-related venous thrombosis is a common but serious clinical complication, thus prevention and treatment on this problem should be extensively investigated. In this research, we aimed to investigate the incidence rate of CVC-related venous thrombosis in senile patients and give a further discussion on the related risk factors and predictors. A total of 324 hospitalized senile male patients subjected to CVC were selected. Retrospective investigation and analysis were conducted on age, underlying diseases, clinical medications, catheterization position and side, catheter retention time, and incidence of CVC-related venous thrombosis complications. Basic laboratory test results during catheterization and thrombogenesis were also collected and analyzed. Among the 324 patients, 20 cases (6.17%) of CVC-related venous thrombosis were diagnoseds. The incidence rate of CVC-related venous thrombosis in subclavian vein catheterization was significantly lower than that in femoral vein catheterization (P<0.01) and that in internal jugular vein catheterization (P<0.05). No statistically significant difference was found between femoral vein catheterization and internal jugular vein catheterization (P<0.05). Previous venous thrombosis history (P<0.01), high lactate dehydrogenase level (P<0.01), low high-density lipoprotein (HDL) level (P<0.05), and low albumin level (P<0.05) were found as risk factors or predictors of CVC-related venous thrombosis in senile male patients. Subclavian vein catheterization was the most appropriate choice among senile patients to decrease the incidence of CVC-related venous thrombosis. Previous venous thrombosis history, high lactate dehydrogenase level, low HDL level, and low albumin level were important risk factors in predicting CVC-related venous thrombosis.
Noninvasive measurement of central venous pressure
NASA Technical Reports Server (NTRS)
Webster, J. G.; Mastenbrook, S. M., Jr.
1972-01-01
A technique for the noninvasive measurement of CVP in man was developed. The method involves monitoring venous velocity at a point in the periphery with a transcutaneous Doppler ultrasonic velocity meter while the patient performs a forced expiratory maneuver. The idea is the CVP is related to the value of pressure measured at the mouth which just stops the flow in the vein. Two improvements were made over the original procedure. First, the site of venous velocity measurement was shifted from a vein at the antecubital fossa (elbow) to the right external jugular vein in the neck. This allows for sensing more readily events occurring in the central veins. Secondly, and perhaps most significantly, a procedure for obtaining a curve of relative mean venous velocity vs mouth pressure was developed.
Merchaoui, Zied; Lausten-Thomsen, Ulrik; Pierre, Florence; Ben Laiba, Maher; Le Saché, Nolwenn; Tissieres, Pierre
2017-01-01
The correct choice of intra vascular access in critically ill neonates should be individualized depending on the type and duration of therapy, gestational and chronological age, weight and/or size, diagnosis, clinical status, and venous system patency. Accordingly, there is an ongoing demand for optimization of catheterization. Recently, the use of ultrasound (US)-guided cannulation of the subclavian vein (SCV) has been described in children and neonates. This article gives an overview of the current use of US for achieving central venous catheter placement in the SCV or the brachiocephalic vein (BCV) in neonates. More than 1,250 catheters have been reported inserted in children and neonates for a cumulated success rate of 98.4% and the complication rate is reported to be low. The technical aspects of various approaches are discussed, and we offer our recommendation of an US-guided technique for SCV and BCV cannulation based on our experience in a large NICU setting. Although the cannulation the SCV or BCV does not substitute the use of peripherally inserted central catheters or umbilical venous central catheters in neonates, it is a feasible route in very small children who are in need of a large caliber central venous access. PMID:29051889
Martinez, Luis R; Mihu, Mircea Radu; Tar, Moses; Cordero, Radames J B; Han, George; Friedman, Adam J; Friedman, Joel M; Nosanchuk, Joshua D
2010-05-01
Candida species are a major cause of catheter infections. Using a central venous catheter Candida albicans biofilm model, we demonstrated that chitosan, a polymer isolated from crustacean exoskeletons, inhibits candidal biofilm formation in vivo. Furthermore, chitosan statistically significantly decreased both the metabolic activity of the biofilms and the cell viability of C. albicans and Candida parapsilosis biofilms in vitro. In addition, confocal and scanning electron microscopic examination demonstrated that chitosan penetrates candidal biofilms and damages fungal cells. Importantly, the concentrations of chitosan that were used to evaluate fungal biofilm susceptibility were not toxic to human endothelial cells. Chitosan should be considered for the prevention or treatment of fungal biofilms on central venous catheters and perhaps other medical devices.
Ahn, Se Jin; Chung, Jin Wook; An, Sang Bu; Yin, Yong Hu; Jae, Hwan Jun; Park, Jae Hyung
2012-01-01
Objective To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. Materials and Methods We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. Results A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). Conclusion Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate. PMID:22563269
Spatial interaction between tissue pressure and skeletal muscle perfusion during contraction.
van Donkelaar, C C; Huyghe, J M; Vankan, W J; Drost, M R
2001-05-01
The vascular waterfall theory attributes decreased muscle perfusion during contraction to increased intramuscular pressure (P(IM)) and concomitant increase in venous resistance. Although P(IM) is distributed during contractions, this theory does not account for heterogeneity. This study hypothesises that pressure heterogeneity could affect the interaction between P(IM) rise and perfusion. Regional tissue perfusion during submaximum (100kPa) tetanic contraction is studied, using a finite element model of perfused contracting skeletal muscle. Capillary flow in muscles with one proximal artery and vein (SIM(1)) and with an additional distal artery and vein (SIM(2)) is compared. Blood flow and pressures at rest and P(IM) during contraction ( approximately 25kPa maximally) are similar between simulations, but capillary flow and venous pressure differ. In SIM(2), venous pressure and capillary flow correspond to P(IM) distribution, whereas capillary flow in SIM(1) is less than 10% of flow in SIM(2), in the muscle half without draining vein. This difference is caused by a high central P(IM), followed by central venous pressure rise, in agreement with the waterfall theory. The high central pressure (SIM(1)), obstructs outflow from the distal veins. Distal venous pressure rises until central blood pressure is reached, although local P(IM) is low. Adding a distal vein (SIM(2)) restores the perfusion. It is concluded that regional effects contribute to the interaction between P(IM) and perfusion during contraction. Unlike stated by the vascular waterfall theory, venous pressure may locally exceed P(IM). Although this can be explained by the principles of this theory, the theory does not include this phenomenon as such.
A Life-Threatening Mediastinal Hematoma After Central Venous Port System Implantation
Sarach, Janine; Zschokke, Irin; Melcher, Gian A.
2015-01-01
Patient: Female, 68 Final Diagnosis: Mediastinal hematoma Symptoms: Agitation • severe hemodynamic instability • severe respiratory distress Medication: — Clinical Procedure: Cardiopulmonary resuscitation • reintubation • thoracic drain Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: We report a case of surgical central venous port system implantation using Seldinger’s technique with a life-threatening mediastinal hematoma due to the perforation of the superior vena cava. Case Report: A 68-year-old woman was admitted to our institution for port implantation. Open access to the cephalic vein and 2 punctures of the right subclavian vein were unsuccessful. Finally, the port catheter could be placed into the superior vena cava using Seldinger’s technique. As blood aspiration via the port catheter was not possible, fluoroscopy was performed, revealing mediastinal contrast extravasation without contrasting the venous system. A new port system could be placed in the correct position without difficulties. After extubation, the patient presented with severe respiratory distress and required consecutive cardiopulmonary resuscitation and reintubation. The CT scan showed a significant hematoma in the lower neck and posterior mediastinum with tracheal compression. We assumed a perforation of the superior vena cava with the tip of the guidewire using Seldinger’s technique. Long-term intensive treatment with prolonged ventilation and tracheotomy was necessary. The port system had to be subsequently explanted due to infection. Conclusions: Mediastinal hematoma is a rare but life-threatening complication associated with central venous catheterization using Seldinger’s technique. Perforation occurs most often during central venous catheterization in critical care. Mediastinal hematoma is an example of a mechanical complication occurring after central venous catheterization, which has been described only a few times in the literature to date. This case highlights the importance of awareness of possible, rare, life-threatening complications during port implantation, mostly performed in multimorbid patients by surgeons in training. PMID:26703924
Venous thrombosis and stenosis after peripherally inserted central catheter placement in children.
Shin, H Stella; Towbin, Alexander J; Zhang, Bin; Johnson, Neil D; Goldstein, Stuart L
2017-11-01
Peripherally inserted central catheters (PICCs) can lead to development of venous thrombosis and/or stenosis. The presence of venous thrombosis and/or stenosis may preclude children with chronic medical conditions from receiving lifesaving therapies, from hemodialysis in end-stage renal disease to total parenteral nutrition in short bowel syndrome. Several adult studies have found an association between PICCs and venous thrombosis and/or stenosis, but none has evaluated for this association in children. To determine the incidence of venous thrombosis and/or stenosis after PICC placement and identify factors that increase the risk of venous thrombosis and/or stenosis after PICC placement in children. We conducted a retrospective review of children ages 1-18 years with a PICC placed between January 2010 and July 2013 at our center, and included those who had at least one vascular imaging study of the ipsilateral extremity (Doppler ultrasound, venogram or MR angiogram) after PICC placement. Logistic regression was applied to determine risk factors for development of venous thrombosis and/or stenosis. One thousand, one hundred and ten upper extremity PICCs were placed, with 703 PICCs in the right and 407 PICCs in the left. Eight hundred fifty-one imaging studies (609 Doppler ultrasounds, 193 contrast venograms and 49 MR angiograms) were performed in 376 patients. The incidence of venous thrombosis and/or stenosis in the imaged cohort was 26.3%. PICC laterality, insertion site, duration, patient height to PICC diameter ratio, and number of PICCs per patient were not associated with development of venous thrombosis and/or stenosis. Additionally, primary diagnosis and symptoms at the time of imaging did not predict findings of venous thrombosis and/or stenosis. However, patients exposed to non-PICC central venous catheters (CVC) were more likely to develop venous thrombosis and/or stenosis (odds ratio 1.95, 1.10-3.45). More than a quarter of the vascular imaging studies performed in this study cohort showed previously unknown venous thrombosis and/or stenosis, irrespective of PICC laterality, insertion site, duration and size and the number of PICCs. A history of CVC was associated with a nearly two-fold increase in risk of venous thrombosis and/or stenosis after PICC placement. We suggest that PICCs and CVCs should be placed judiciously in all children, but especially in those with lifelong medical conditions who are more likely to incur direct consequences from limited vascular access.
ERIC Educational Resources Information Center
Ma, Irene W. Y.; Zalunardo, Nadia; Pachev, George; Beran, Tanya; Brown, Melanie; Hatala, Rose; McLaughlin, Kevin
2012-01-01
The use of checklists is recommended for the assessment of competency in central venous catheterization (CVC) insertion. To explore the use of a global rating scale in the assessment of CVC skills, this study seeks to compare its use with two checklists, within the context of a formative examination using simulation. Video-recorded performances of…
Clinical Investigation Service Annual Research Progress Report Fiscal Year 1980,
1980-10-01
Capillary (Heelstick) and Central ( Venous ) 136 Total White Blood Cell Counts and Differentials in Normal Newborn Infants (0) PHYSICAL MEDICINE...Comparison of Capillary (Heelstick) and Central ( Venous ) Total White Blood Cell Counts and Differentials in Normal Newborn Infants PRINCIPAL INVESTIGATOR...tolerance tests with renal glycosuria shall be evaluated. Day 1: History , physical examination, routine CBC, chest x-ray, STS, regular hospital diet (300 gm
Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rajan, Dheeraj K., E-mail: dheeraj.rajan@uhn.on.ca; Saluja, Jasdeep S.
2007-07-15
Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm.more » The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is associated with good mid-term patency and may exceed historical observations with prior use of Wallstents.« less
Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos
2017-02-27
Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly reduce transfusion of blood products in this population, leading to a reduction in costs and transfusion-related adverse reactions. In this manner, this trial will add evidence in favor of reducing empirical transfusion in severely ill patients with coagulopathy. ClinicalTrials.gov, identifier: NCT02311985 . Retrospectively registered on 3 December 2014.
Peripheral arteriovenous fistula as vascular access for long-term chemotherapy.
Kovalyov, Oleksiy O; Kostyuk, Oleksandr G; Tkachuk, Tetyana V
To provide long-term vascular access in clinical oncology peripheral forearm veins (up to 95% of patients in Ukraine), central venous access and "complete implanted vascular systems" are used most often. Many oncology patients have contraindications to catheterization of superior vena cava. Besides, exploitation of central veins is associated with potential technical and infectious complications. The aim - to study short-term and long-term results of arteriovenous fistula exploitation as vascular access for continuous anticancer therapy. Peripheral venous bed status in 41 oncology patients taking long-term chemotherapy treatment is analyzed in the article. Doppler sonography, morphologic and immune histochemical analyses were used in the study. Doppler sonography found qualitative and quantitative changes in forearm veins at different time periods after initiation of chemotherapy in the majority of patients. The major morphologic manifestations of venous wall damage were chemical phlebitis, local or extended hardening of venous wall, venous thrombosis and extravasations with necrosis and subsequent paravasal tissue sclerosis. Alternative vascular access created in 12 patients completely met the adequacy criteria (safety, multiple use, longevity, realization of the designed therapy program). The conclusion was made about inapplicability of forearm veins for long-term administration of cytostatic agents. If it is impossible to use central veins, arteriovenous fistula can become an alternative vascular access.
[Injuries to blood vessels near the heart caused by central venous catheters].
Abram, J; Klocker, J; Innerhofer-Pompernigg, N; Mittermayr, M; Freund, M C; Gravenstein, N; Wenzel, V
2016-11-01
Injuries to blood vessels near the heart can quickly become life-threatening and include arterial injuries during central venous puncture, which can lead to hemorrhagic shock. We report 6 patients in whom injury to the subclavian artery and vein led to life-threatening complications. Central venous catheters are associated with a multitude of risks, such as venous thrombosis, air embolism, systemic or local infections, paresthesia, hemothorax, pneumothorax, and cervical hematoma, which are not always immediately discernible. The subclavian catheter is at a somewhat lower risk of catheter-associated sepsis and symptomatic venous thrombosis than approaches via the internal jugular and femoral veins. Indeed, access via the subclavian vein carries a substantial risk of pneumo- and hemothorax. Damage to the subclavian vein or artery can also occur during deliberate and inadvertent punctures and result in life-threatening complications. Therefore, careful consideration of the access route is required in relation to the patient and the clinical situation, to keep the incidence of complications as low as possible. For catheterization of the subclavian vein, puncture of the axillary vein in the infraclavicular fossa is a good alternative, because ultrasound imaging of the target vessel is easier than in the subclavian vein and the puncture can be performed much further from the lung.
Lim, Byung Gun; Kim, Young Min; Kim, Heezoo; Lim, Sang Ho; Lee, Mi Kyoung
2011-12-01
A 41-year-old woman, who had no thrombotic risk factors and past history except congenital scoliosis, underwent central venous catheterization (CVC) before correction of the scoliosis. When internal jugular vein (IJV) catheterization using the anatomical landmark technique failed, CVC under ultrasound guidance was tried. As a consequence, thrombosis and hypoplasia of the right IJV were incidentally detected by ultrasonography. Central venous catheters were then successfully placed in other veins under ultrasound guidance. Also, after examinations to rule out the possibility of pulmonary embolism and to clarify the causes of the IJV thrombosis, the patient was found to have protein S deficiency. CVC under ultrasound guidance should be recommended to prevent the failure of cannulation and complications such as thromboembolism in patients who could possibly have anomalies of vessels as a result of anatomical deformities caused by severe scoliosis, even if patients do not have thrombotic risk factors such as a history of central catheter insertion or intravenous drug abuse, cancer, advanced age, cerebral infarction, and left ventricular dysfunction. Also, if venous thrombosis is found in patients without predisposing risk factors, one should ascertain the cause of the hypercoagulable state, for example protein S deficiency, and perform appropriate treatment and prevention of venous thromboembolism.
Congestive renal failure: the pathophysiology and treatment of renal venous hypertension.
Ross, Edward A
2012-12-01
Longstanding experimental evidence supports the role of renal venous hypertension in causing kidney dysfunction and "congestive renal failure." A focus has been heart failure, in which the cardiorenal syndrome may partly be due to high venous pressure, rather than traditional mechanisms involving low cardiac output. Analogous diseases are intra-abdominal hypertension and renal vein thrombosis. Proposed pathophysiologic mechanisms include reduced transglomerular pressure, elevated renal interstitial pressure, myogenic and neural reflexes, baroreceptor stimulation, activation of sympathetic nervous and renin angiotensin aldosterone systems, and enhanced proinflammatory pathways. Most clinical trials have addressed the underlying condition rather than venous hypertension per se. Interpreting the effects of therapeutic interventions on renal venous congestion are therefore problematic because of such confounders as changes in left ventricular function, cardiac output, and blood pressure. Nevertheless, there is preliminary evidence from small studies of intense medical therapy or extracorporeal ultrafiltration for heart failure that there can be changes to central venous pressure that correlate inversely with renal function, independently from the cardiac index. Larger more rigorous trials are needed to definitively establish under what circumstances conventional pharmacologic or ultrafiltration goals might best be directed toward central venous pressures rather than left ventricular or cardiac output parameters. Copyright © 2012 Elsevier Inc. All rights reserved.
The antigravity suit in neurosurgery. Cardiovascular responses in seated neurosurgical patients.
Brodrick, P M; Ingram, G S
1988-09-01
The haemodynamic responses associated with inflation of the antigravity suit (G suit, aviation type) to 8.0 kPa were studied in a series of 40 patients who underwent neurosurgical operations in the sitting position. The study showed statistically significant increases in systolic arterial pressure (p less than 0.005) and mean central venous pressure (p less than 0.001) with inflation of the suit. The systolic arterial and mean central venous pressures remained significantly elevated immediately before deflation of the suit at the end of the operation (p less than 0.001 and p less than 0.005 respectively). The addition of 0.8-1.0 kPa positive end expiratory pressure during suit inflation was also investigated. A further increase in central venous pressure occurred but this did not achieve statistical significance.
1991-07-30
of etiologies that reduce cardiac output by mechanically obstructing venous return. E Central venous catheterization can be performed rapidly and...is planned that this will be tested in early August 1991. Data acquired will include arterial and venous blood pressure, heart rate, temperature...appropriate for PE acconplaned by rise in ZT02 & Increased venous pressures 17 No End rtIfact Yes Examine 7aveforn -changefilter 7 A5 DECLSION TREE FOR RM IN
Journal of Special Operations Medicine, Volume 7, Edition 2, Spring 2007
2007-01-01
to help preclude dislodgement. Single-lumen central venous /jugular catheters are not difficult to place in an otherwise fit and well-conditioned MWD...progressively lost favor since the intro- duction of the Seldinger technique of central venous line placement. In fact, recent editions of the Advanced...latest advancements in medicine and the history of unconventional warfare medicine. Disclosure Statement: The JSOM presents both medical and nonmedical
Pacific Pediatric Advanced Care Initiative
2011-01-01
infusing into the patient via a central venous line 6. After you have made sure the patient is safe, remove air from system. 7. Identify and fix...site. Push blood. Take fluid out of bladder to create a more negative venous pressure History : Day 1 for a 2 month old who had a witnessed...operating room, central supply, pharmacy, respiratory care, Neonatal Intensive Care Unit (NICU) nursing, Pediatric Intensive Care Unit (PICU) nursing, Risk
Guijarro Escribano, J F; Antón, R F; Colmenarejo Rubio, A; Sáenz Cascos, L; Sainz González, F; Alguacil Rodríguez, R
2007-03-01
Recently, there has been an increase in the number of cases of superior vena cava (SVC) syndrome associated with chronic indwelling central venous catheters. Fibrinolytic therapy and endovascular treatment are currently achieving good results. We present a case history of a patient with SVC with a catheter used for chemotherapy, which was successfully treated with catheter-directed (intraclot) infusion thrombolytic therapy with urokinase.
Mycobacterium phocaicum bacteremia: an emerging infection in pediatric hematology-oncology patients.
Shachor-Meyouhas, Yael; Geffen, Yuval; Arad-Cohen, Nira; Zaidman, Irina; Ben-Barak, Ayelet; Davidson, Sima; Kassis, Imad
2014-12-01
Nontuberculous mycobacteria may cause central venous catheter-associated bacteremia. Between March 2011 and October 2013, 6 cases of Mycobacterium phocaicum bacteremia were found in the pediatric hematology-oncology department. All patients recovered. No positive blood culture was documented after removal of the central venous catheter. All 4 patients with pulsed field gel electrophoresis had the same pattern, different from the water sample, suggesting a common water source.
Craft, Christopher; Feldon, David F; Brown, Eric A
2014-05-01
Simulation-based learning is a common educational tool in health care training and frequently involves instructional designs based on Experiential Learning Theory (ELT). However, little research explores the effectiveness and efficiency of different instructional design methodologies appropriate for simulations. The aim of this study was to compare 2 instructional design models, ELT and Guided Experiential Learning (GEL), to determine which is more effective for training the central venous catheterization procedure. Using a quasi-experimental randomized block design, nurse anesthetists completed training under 1 of the 2 instructional design models. Performance was assessed using a checklist of central venous catheterization performance, pass rates, and critical action errors. Participants in the GEL condition performed significantly better than those in the ELT condition on the overall checklist score after controlling for individual practice time (F[1, 29] = 4.021, P = .027, Cohen's d = .71), had higher pass rates (P = .006, Cohen's d = 1.15), and had lower rates of failure due to critical action errors (P = .038, Cohen's d = .81). The GEL model of instructional design is significantly more effective than ELT for simulation-based learning of the central venous catheterization procedure, yielding large differences in effect size. Copyright © 2014 Elsevier Inc. All rights reserved.
Morrison, James; Kaufman, John
2016-12-01
Vascular access is invaluable in the treatment of hospitalized patients. Central venous catheters provide a durable and long-term solution while saving patients from repeated needle sticks for peripheral IVs and blood draws. The initial catheter placement procedure and long-term catheter usage place patients at risk for infection. The goal of this project was to develop a system to track and evaluate central line-associated blood stream infections related to interventional radiology placement of central venous catheters. A customized web-based clinical database was developed via open-source tools to provide a dashboard for data mining and analysis of the catheter placement and infection information. Preliminary results were gathered over a 4-month period confirming the utility of the system. The tools and methodology employed to develop the vascular access tracking system could be easily tailored to other clinical scenarios to assist in quality control and improvement programs.
Atchison, Christie M; Amankwah, Ernest; Wilhelm, Jean; Arlikar, Shilpa; Branchford, Brian R; Stock, Arabela; Streiff, Michael; Takemoto, Clifford; Ayala, Irmel; Everett, Allen; Stapleton, Gary; Jacobs, Marshall L; Jacobs, Jeffrey P; Goldenberg, Neil A
2018-02-01
Paediatric hospital-associated venous thromboembolism is a leading quality and safety concern at children's hospitals. The aim of this study was to determine risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or therapeutic cardiac catheterisation. We conducted a retrospective, case-control study of children admitted to the cardiovascular intensive care unit at Johns Hopkins All Children's Hospital (St. Petersburg, Florida, United States of America) from 2006 to 2013. Hospital-associated venous thromboembolism cases were identified based on ICD-9 discharge codes and validated using radiological record review. We randomly selected two contemporaneous cardiovascular intensive care unit controls without hospital-associated venous thromboembolism for each hospital-associated venous thromboembolism case, and limited the study population to patients who had undergone cardiothoracic surgery or therapeutic cardiac catheterisation. Odds ratios and 95% confidence intervals for associations between putative risk factors and hospital-associated venous thromboembolism were determined using univariate and multivariate logistic regression. Among 2718 admissions to the cardiovascular intensive care unit during the study period, 65 met the criteria for hospital-associated venous thromboembolism (occurrence rate, 2%). Restriction to cases and controls having undergone the procedures of interest yielded a final study population of 57 hospital-associated venous thromboembolism cases and 76 controls. In a multiple logistic regression model, major infection (odds ratio=5.77, 95% confidence interval=1.06-31.4), age ⩽1 year (odds ratio=6.75, 95% confidence interval=1.13-160), and central venous catheterisation (odds ratio=7.36, 95% confidence interval=1.13-47.8) were found to be statistically significant independent risk factors for hospital-associated venous thromboembolism in these children. Patients with all three factors had a markedly increased post-test probability of having hospital-associated venous thromboembolism. Major infection, infancy, and central venous catheterisation are independent risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or cardiac catheter-based intervention, which, in combination, define a high-risk group for hospital-associated venous thromboembolism.
Risk factors for venous thrombosis associated with peripherally inserted central venous catheters
Pan, Longfang; Zhao, Qianru; Yang, Xiangmei
2014-01-01
To evaluate the risk factors associated with an increased risk of symptomatic peripherally inserted central venous catheter (PICC)-related venous thrombosis. Retrospective analyses identified 2313 patients who received PICCs from 1 January 2012 to 31 December 2013. All 11 patients with symptomatic PICC-related venous thrombosis (thrombosis group) and 148 who did not have thromboses (non-thrombosis group) were selected randomly. The medical information of 159 patients (age, body mass index (BMI), diagnosis, smoking history, nutritional risk score, platelet count, leucocyte count as well as levels of D-dimer, fibrinogen, and degradation products of fibrin) were collected. Logistic regression analysis was undertaken to determine the risk factors for thrombosis. Of 2313 patients, 11 (0.47%) were found to have symptomatic PICC-related venous thrombosis by color Doppler ultrasound. Being bedridden for a long time (odds ratio [(OR]), 17.774; P=0.0017), D-dimer >5 mg/L (36.651; 0.0025) and suffering from one comorbidity (8.39; 0.0265) or more comorbidities (13.705; 0.0083) were the major risk factors for PICC-catheter related venous thrombosis by stepwise logistic regression analysis. Among 159 patients, the prevalence of PICC-associated venous thrombosis in those with ≥1 risk factor was 10.34% (12/116), in those with ≥2 risk factors was 20.41% (10/49), and in those with >3 risk factors was 26.67% (4/15). Being bedridden >72 h, having increased levels of D-dimer (>5 mg/L) and suffering from comorbidities were independent risk factors of PICC-related venous thrombosis. PMID:25664112
Extravasation from venous catheter: a serious complication potentially missed by lung imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spicer, K.M.; Gordon, L.
Three patients were referred for lung ventiliation and perfusion (V/Q) imaging with symptoms strongly suggestive of pulmonary embolus (PE). Chest roentgenograms and xenon ventilation studies on all three were normal, save for prominent mediastinal silhouettes and effusions. Technetium-99m macroaggregated albumin(Tc-99m MAA), when injected through the central venous catheter (CVP), revealed mediastinal localization, whereas antecubital injections showed normal pulmonary perfusion. Contrast fluoroscopy introduced through the venous catheter in the first patient defined the extravasation. For patients under strong suspicion of PE, with a venous catheter whose distal tip is seen about the level of the heart on chest radiograph, the authorsmore » recommend administering the perfusion agent slowly through the central catheter to exclude catheter-induced complications. When extravasation is detected, injection of Tc-99m MAA by peripheral vein should be used to exclude PE.« less
Endovascular treatment of central venous stenosis and obstruction in hemodialysis patients.
Shi, Ya-xue; Ye, Meng; Liang, Wei; Zhang, Hao; Zhao, Yi-ping; Zhang, Ji-wei
2013-02-01
Central venous stenosis and obstruction (CVD) is a serious and prevalent challenge to both resolve the venous hypertension symptoms and maintain the pantency of the ipsilateral hemodialysis access in hemodialysis patients. This study aimed to summarize our experience of the endovascular management of the central venous stenosis or obstruction in hemodialysis patients. Twenty-four haemodialysis cases of central vein stenosis or obstruction with ipsilateral functional vascular access in our hospital between July 2006 and February 2012 were treated by interventional therapy and the data were analyzed retrospectively. Eighteen males and six females with mean age of (66.4 ± 13.8) years and manifesting with arm swelling and venous hypertension were enrolled; 62.5% of them had a history of catheterization. Venography showed stenotic lesion in 10 cases including eight cases of brachiocephalic vein stenosis and two cases of subclavian vein stenosis and 14 cases of obstruction lesions including seven cases of short brachiocephalic obstruction and seven cases of long segment obstruction. Interventional therapy was performed and the technique success rate was 83.3%. Percutaneous transluminal angioplasty (PTA) was performed in nine cases and stent was performed in 11 cases firstly. The symptoms of venous hypertension were resolved after intervention in all the cases. There was no major complication and death perioperatively. During follow-up, reintervention was done, the primary patency rates were (88.9 ± 10.5)%, (64.8 ± 10.5)% and (48.6 ± 18.7)% at 3 months, 6 months and 1 year after treatment in the PTA group; (90.0 ± 9.5)% and (77.1 ± 14.4)% at 6 months and 1 year after treatment in the stent group, respectively. The secondary patency rates were (48.6 ± 18.7)% in the PTA group and (83.3 ± 15.2)% in the stent group 1 year after treatment, respectively. There was no significant difference between the two groups (primary patency, P = 0.20; secondary patency, P = 0.10). The endovascular intervention is a safe and effective method for CVD in short term; enhanced follow-up and repeated interventions are required to maintain patency for long term. The prevention is most important. Avoiding and minimizing the placement of the central venous catheter may be the key point for the prevention.
Lindquester, Will S; Hawkins, C Matthew; Monroe, Eric J; Gill, Anne E; Shivaram, Giridhar M; Seidel, F Glen; Lungren, Matthew P
2017-11-01
Despite the demonstrated feasibility of the single-stick technique in the femoral vein, its use in neonates and infants for placing central lines in internal and external jugular veins has not been reported. Describe and assess the safety and efficacy of tunneled jugular central venous catheter placement performed under ultrasound (US) and fluoroscopic guidance in neonates and infants weighing <5 kg using the single-stick technique at three tertiary pediatric hospitals. Thirty-three children weighing less than 5 kg received tunneled central venous access in either internal or external jugular veins using the single-stick technique. Patient history, procedural records and clinical follow-up documents were retrospectively reviewed. Complication rates were compared to those of 41 patients receiving single-stick femoral central lines. Technical complications occurred during one (3.0%) jugular placement with the patient having a failed right-side attempt with subsequent successful left-side placement. The catheters did not last the entire course of treatment in three (9.1%) patients with jugular lines. One patient had the catheter removed due to concern for infection, one catheter was accidentally removed during dressing changes, and one catheter was displaced and subsequently exchanged. Of patients receiving femoral central lines, 1 (2.4%) had a technical complication and 5 catheters (12.2%) did not last the entire course of treatment. The placement of tunneled central venous catheters in neonates/infants <5 kg is safe and technically feasible using the internal/external jugular vein via the single-stick technique. By theoretically reducing the risks of catheter infection by avoiding the diaper area and thrombosis by using larger veins, it may be preferable in certain patient populations.
Total anomalous systemic venous drainage in left heterotaxy syndrome.
Khandenahally, Ravindranath S; Deora, Surender; Math, Ravi S
2013-04-01
Total anomalous systemic venous drainage is an extremely rare congenital heart defect. In this study we describe an 11-year-old girl who presented with a history of fatigue and central cyanosis that she had had since early childhood with unremarkable precordial examination results. Investigations revealed left heterotaxy with all systemic venous drainage to the left-sided atrium with non-compaction of the left ventricle.
Douard, M C; Ardoin, C; Payri, L; Tarot, J P
1999-03-01
Implantable venous ports and Hickman central venous catheters are widely used in patients with cancer, blood disorders, or HIV infection, both for in-hospital care and at home. Infectious complications are among the common causes for readmission in these patients. The present review discusses the incidence, risk factors, and diagnostic tools for infectious complications associated with long-term venous access devices.
Maximal venous outflow velocity: an index for iliac vein obstruction.
Jones, T Matthew; Cassada, David C; Heidel, R Eric; Grandas, Oscar G; Stevens, Scott L; Freeman, Michael B; Edmondson, James D; Goldman, Mitchell H
2012-11-01
Leg swelling is a common cause for vascular surgical evaluation, and iliocaval obstruction due to May-Thurner syndrome (MTS) can be difficult to diagnose. Physical examination and planar radiographic imaging give anatomic information but may miss the fundamental pathophysiology of MTS. Similarly, duplex ultrasonographic examination of the legs gives little information about central impedance of venous return above the inguinal ligament. We have modified the technique of duplex ultrasonography to evaluate the flow characteristics of the leg after tourniquet-induced venous engorgement, with the objective of revealing iliocaval obstruction characteristic of MTS. Twelve patients with signs and symptoms of MTS were compared with healthy control subjects for duplex-derived maximal venous outflow velocity (MVOV) after tourniquet-induced venous engorgement of the leg. The data for healthy control subjects were obtained from a previous study of asymptomatic volunteers using the same MVOV maneuvers. The tourniquet-induced venous engorgement mimics that caused during vigorous exercise. A right-to-left ratio of MVOV was generated for patient comparisons. Patients with clinical evidence of MTS had a mean right-to-left MVOV ratio of 2.0, asymptomatic control subjects had a mean ratio of 1.3, and MTS patients who had undergone endovascular treatment had a poststent mean ratio of 1.2 (P = 0.011). Interestingly, computed tomography and magnetic resonance imaging results, when available, were interpreted as positive in only 53% of the patients with MTS according to both our MVOV criteria and confirmatory venography. After intervention, the right-to-left MVOV ratio in the MTS patients was found to be reduced similar to asymptomatic control subjects, indicating a relief of central venous obstruction by stenting the compressive MTS anatomy. Duplex-derived MVOV measurements are helpful for detection of iliocaval venous obstruction, such as MTS. Right-to-left MVOV ratios and postengorgement spectral analysis are helpful adjuncts to duplex imaging for leg swelling. The MVOV maneuvers are well tolerated by patients and yields physiological data regarding central venous obstruction that computed tomography and magnetic resonance imaging fail to detect. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.
Madias, John E
2004-04-01
The author describes his experience with a "saline-filled central venous catheter electrocardiographic lead" for the recording of intracardiac electrocardiograms provides a brief description of the methodology, refers to this modality's clinical usefulness, furnishes 2 examples illustrating the contribution of the method to clinical diagnosis, and outlines his literature search to find the discoverer/originator of the employment of a saline-filled intracardiac catheter as an electrocardiogram recording lead.
1994-04-01
that the peripheral vasoconstriction resulting from cold exposure leads to an increase in central venous return, increased central venous pressure, and...AD-A279 775 -; lilli IIIIIII lIII 11lU~lMuli/II I IIIll 1993 COMMAND HISTORY Compiled by R. E. Gadolin and K. S. Mayer DTIC SL ELECTE MAYSI11941) v F...distribution unlimited. NAVAL AEROSPACE MEDICAL RESEARCH LABORATORY 51 HOVEY ROAD, PENSACOLA, FLORIDA 32508-1046 1993 COMMAND HISTORY Compiled by R.E. Gadolin
[Doctor-nurse delegation of the insertion of central venous lines].
Cellupica, Mary
2015-01-01
The Léon Bérard Cancer Centre treats the disease in all its complexity with numerous disciplines such as surgery, medicine, radiotherapy, palliative care, home care, etc. The insertion of a central venous line is an essential part of cancer care and the nursing profession. It enables patients to have their treatment administered in the best possible conditions and without risk. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Lights, camera and action in the implementation of central venous catheter dressing1
Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise
2015-01-01
Objective: to develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. Method: this is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. Results: the items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. Conclusion: the educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters. PMID:26626011
Lights, camera and action in the implementation of central venous catheter dressing.
Ferreira, Maria Verônica Ferrareze; de Godoy, Simone; de Góes, Fernanda dos Santos Nogueira; Rossini, Fernanda de Paula; de Andrade, Denise
2015-01-01
To develop and validate an educational digital video on changing the dressing of short-term, non-cuffed, non-tunneled central venous catheters in hospitalized adult patients. This is a descriptive, methodological study based on Paulo Freire's assumptions. The development of the script and video storyboard were based on scientific evidence, on the researchers' experience, and that of nurse experts, as well as on a virtual learning environment. The items related to the script were approved by 97.2% of the nurses and the video was approved by 96.1%. The educational instrument was considered to be appropriate and we believe it will contribute to professional training in the nursing field, the updating of human resources, focusing on the educational process, including distance education. We believe it will consequently improve the quality of care provided to patients with central venous catheters.
Assistive technology for ultrasound-guided central venous catheter placement.
Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana
2018-01-01
This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.
Nowak, Łukasz R; Duda, Krzysztof; Mizianty, Marek; Wilczek, Małgorzata; Bieda, Tomasz
2015-01-01
Horner syndrome is a rare but likely underdiagnosed complication of internal jugular vein cannulation. We present a case of a young woman undergoing chemotherapy for gestational trophoblastic disease for whom venous port implantation was attempted due to poor peripheral vein access. Despite ultrasound guidance, the procedure was unsuccessful and complicated by a local haematoma, causing compression of the sympathetic nerves with Horner syndrome. The symptoms subsided within 3 weeks without treatment. The possible pathomechanisms of Horner syndrome after central venous cannulation are presented with suggested diagnostic and therapeutic approaches. Special emphasis must be placed on excluding carotid artery dissection because it carries the risk of subsequent cerebral vascular incidents. In the event of a carotid dissection, a multidisciplinary team must choose a pharmacological (antiplatelet drugs/anticoagulation) or interventional approach. Even with ultrasonography, central venous cannulation is not free of serious risks. In case of anisocoria following an uneventful procedure, diagnostic imaging of the vascular structures in the neck is mandatory for the exclusion of potentially serious complications, such as carotid dissection or venous thrombosis.
Chmielak, Zbigniew; Dębski, Artur; Kępka, Cezary; Rudziński, Piotr N.; Bujak, Sebastian; Skwarek, Mirosław; Kurowski, Andrzej; Dzielińska, Zofia; Demkow, Marcin
2016-01-01
Introduction Totally implantable venous access systems (TIVAS), Swan-Ganz (SG) and central venous catheters (CVC) allow easy and repetitive entry to the central cardiovascular system. Fragments of them may be released inadvertently into the cardiovascular system during their insertion or as a result of mechanical complications encountered during long-term utilization. Aim To present results of percutaneous retrieval of embolized fragments of central venous devices or knotted SG and review the procedural aspects with a series of detailed angiographies. Material and methods Between January 2003 and December 2012 there were 14 (~0.025%) successful retrievals in 13 patients (44 ±16 years, 15% females) of embolized fragments of TIVAS (n = 10) or CVC (n = 1) or of dislodged guide-wires (n = 2) or knotted SG (n = 1). Results Foreign bodies with the forward end located in the right ventricle (RV), as well as those found in the pulmonary artery (PA), often required repositioning with a pigtail catheter as compared to those catheter fragments which were located in the right atrium (RA) and/or great vein and possessed an accessible free end allowing their direct ensnarement with the loop snare (57.0% (4/7) vs. 66.7% (2/3) vs. 0.0% (0/3); p = 0.074 respectively). Procedure duration was 2–3 times longer among catheters retrieved from the PA than among those with the forward edge located in the RV or RA (30 (18–68) vs. 13.5 (11–37) vs. 8 min (8–13); p = 0.054 respectively). The SG catheter knotted in the vena cava superior (VCS) was encircled with the loop snare introduced transfemorally, subsequently cut at its skin entrance and then pulled down inside the 14 Fr vascular sheath. Conclusions By using the pigtail catheter and the loop snare, it is feasible to retrieve centrally embolized fragments or knotted central venous access devices. PMID:27279874
Díaz-Regañón, Genaro; Miñambres, Eduardo; Holanda, Marisol; González-Herrera, Segundo; López-Espadas, Francisco; Garrido-Díaz, Carlos
2002-12-01
To assess the usefulness of venous oxygen saturation in the jugular bulb (SjO(2)) as a complementary test for the diagnosis of brain death. Prospective observational study. Polytrauma intensive care unit (ICU) of an acute-care teaching hospital in Santander, Spain. We studied 118 (44%) out of 270 patients with severe head injury and intracranial hemorrhage meeting criteria of brain death (lack of cardiac response to atropine, unresponsive apnea, and iso-electric EEG in the absence of shock, hypotension and treatment with muscle relaxants and/or central nervous system (CNS) depressant drugs). At the moment at which clinical diagnosis of brain death was made and an iso-electric EEG was obtained, simultaneous oxygen saturation in central venous blood (right atrium) (SvO(2)) and jugular venous bulb (SjO(2)) samples was measured. The ratio between SvO(2) and SjO(2), expressed as CvjO(2) (the so-called central venous-jugular bulb oxygen saturation rate; CvjO(2) = SvO(2)/SjO(2)) was calculated. CvjO(2) less than 1 was obtained in 114 patients [mean (SD): 0.89 (0.02)], whereas CvjO(2) greater than 1 was obtained in only 4 (3.38%). In the group of 152 survivors, a single patient was discharged from the ICU in a vegetative state in which CvjO(2) was below 1. CvjO(2)as a complementary test for the diagnosis of brain death showed 96.6% sensitivity, 99.3% specificity, and 99.1% and 97.4% positive and negative predictive values, respectively. Central venous-jugular bulb oxygen saturation rate below 1 together with accepted clinical criteria (unresponsive coma with brainstem areflexia) provides non-invasive assessment of cerebral circulatory arrest that can help to suspect brain death.
Cardiac tamponade due to umbilical venous catheter in the new born
Abdellatif, Mohamed; Ahmed, Ashfag; Alsenaidi, Khalfan
2012-01-01
With more and more extreme premature and very low-birth weight babies being resuscitated, umbilical central venous catheterisation is now being used more frequently in neonatal intensive care. The authors present a case of cardiac tamponade following umbilical venous catheterisation in a neonate, an uncommon, yet potentially fatal complication. The patient was diagnosed at the appropriate time by echocardiography and urgent pericardiocentesis proved lifesaving. PMID:22802560
Decompression from Saturation Using Oxygen: Its Effect on DCS and RNA in Large Swine
2010-01-01
mask. The external jugular vein was catheter- ized with a 14-Ga., 30-cm single lumen catheter ( Central Venous Catheterization Set; Arrow... venous catheterization for sequential blood sampling from the pig. J Invest Surg 1991; 4:103-7. 3. Behnke AR. The isobaric (oxygen window) principle of...pressures may lead to toxicity that involves the pulmonary system and/ or the central nervous system (CNS). There is evidence that 100% oxygen in
Noninvasive Methods for Determining Lesion Depth from Vesicant Exposure
2007-01-01
LDPI. Chilcott et al19 used several noninvasive bio- a bolus through a central or peripheral venous line. engineering methods to monitor wound healing...ade- bolus through a central or peripheral venous line. The quate NBF into the tissue, two parallel cuts approxi- first two range finding pigs were...not more than 5.0%), its use creasing the size of the scan area, and/or decreasing is contraindicated in patients with a history of allergy the number
Lautt, W W; Legare, D J; Greenway, C V
1987-11-01
In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)
Kasten, Robert; Pfirrmann, Gudrun; Voigtländer, Volker
2005-08-01
A 43-year-old male with eunuchoid body proportions and a history of deep venous thromboses in the right leg presented with recurrent ulcers in the right perimalleolar region for 6 years. Karyotyping revealed a 47 XXY Klinefelter's syndrome, while serologic testing showed protein S deficiency, hyperhomocysteinemia and positive lupus anticoagulant. He also had mixed connective tissue disease (Sharp's syndrome) with acrosclerosis, proximal finger edema, Raynaud's phenomenon, and high titers of ANA and U1-RNP-antibodies, as well as osteoporosis. There is evidence that patients with Klinefelter's syndrome are prone to develop connective tissue diseases and thrombophilia as a result of low androgen levels. Substitution of testosterone in Klinefelter's syndrome can have a favorable therapeutic effect on the associated connective tissue disease, thrombophilia and osteoporosis.
Haggerty, Christopher M; Fynn-Thompson, Francis; McElhinney, Doff B; Valente, Anne Marie; Saikrishnan, Neelakantan; Del Nido, Pedro J; Yoganathan, Ajit P
2012-09-01
This study sought to evaluate the performance of microaxial ventricular assist devices for the purposes of supporting failing Fontan physiology by decreasing central venous pressure. Three Abiomed Impella pumps (Abiomed, Inc, Danvers, Mass) were evaluated in a mock circulatory system of the Fontan circuit. The local response of pressures and flows to pump function was assessed as a function of pump speed and pulmonary vascular resistance at a high baseline central venous pressure. For one device, subsequent modeling studies were conducted using a lumped parameter model of the single ventricle circuit. The left ventricular devices (Impella 2.5, 5.0) were shown to be suboptimal as single device solutions for cavopulmonary support. The small area of these devices relative to vessel diameter led to significant flow recirculation without an obstructive separator in place. Furthermore, downstream pressure augmentation adversely affected the pressure in the superior vena cava. The use of 2 devices would be mandatory for successful support. The right-sided device (Impella RP), whose outflow was positioned in the left pulmonary artery, demonstrated decreased flow recirculation and did not impede superior caval venous flow. Although static pressure is still required to drive flow through the opposite lung, numeric modeling demonstrated the potential for modest but significant improvements in lowering the central venous pressure (2-8 mm Hg). Left-sided microaxial pumps are not well suited for cavopulmonary support because of severe flow recirculation and the need for multiple devices. The right-ventricular Impella device provides improved performance by directing flow into the pulmonary artery, resulting in modest decreases in central venous pressure. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Cerebral venous circulatory system evaluation by ultrasonography.
Zavoreo, Iris; Basić-Kes, Vanja; Zadro-Matovina, Lucija; Lisak, Marijana; Corić, Lejla; Cvjeticanin, Timon; Ciliga, Dubravka; Bobić, Tatjana Trost
2013-06-01
Venous system can be classified as pulmonary veins, systemic veins and venous sinuses that are present only within the skull. Cerebral venous system is divided into two main parts, the superficial and the deep system. The main assignment of veins is to carry away deoxygenated blood and other maleficient materials from the tissues towards the heart. Veins have thinner walls and larger lumina than arteries. Between 60% and 70% of the total blood volume is found in veins. The major factors that influence venous function are the respiratory cycle, venous tone, the function of the right heart, gravity, and the muscle pump. Venous system, in general, can be presented by selective venography, Doppler sonography, computed tomography (CT) venography and magnetic resonance (MR) venography, and cerebral venous system can be displayed by selective venography, cerebral CT venography, cerebral MR venography, and specialized extracranial and transcranial Doppler sonography. The aim of this paper is to show the possibilities of intracranial and extracranial ultrasound evaluation of the head and neck venous circulation and chronic cerebrospinal venous insufficiency as one of the most common pathologies evaluated as part of neurodegenerative processes in the central nervous system.
Central venous access in children: indications, devices, and risks.
Ares, Guillermo; Hunter, Catherine J
2017-06-01
Central venous catheters (CVCs) have a prominent role in the diagnostic and therapy of neonates and children. Herein, we describe the multiple indications for CVC use and the different devices available for central venous access. Given the prevalent use of CVCs, healthcare systems are focused on reducing complications from their use, particularly central line-associated bloodstream infections (CLABSIs). The most up-to-date information available sheds light on best practices and future areas of investigation. Large systematic reviews of randomized trials suggest that ultrasound guidance for placement of CVCs in children is safer than using blind technique, at least for internal jugular vein access. Appropriate catheter tip placement is associated with decreased complications. Furthermore, the prophylactic use of ethanol lock between cycles of parenteral nutrition administration has reduced the rates of CLABSI. A recent randomized trial in pediatric CVCs showed a benefit with antibiotic-coated CVCs. Based on the available evidence, multiple techniques for CVC placement are still valid, including the landmark technique based on practitioner experience, but ultrasound guidance has been shown to decrease complications from line placement. Adherence to CVC care protocols is essential in reducing infectious complications.
Central venous stenosis in haemodialysis patients without a previous history of catheter placement.
Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek
2005-08-01
To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.
Wilson, Thomas J; Stetler, William R; Fletcher, Jeffrey J
2013-07-01
To compare cumulative complication rates of peripherally (PICC) and centrally (CICVC) inserted central venous catheters, including catheter-related large vein thrombosis (CRLVT), central line-associated bloodstream infection (CLABSI), and line insertion-related complications in neurological intensive care patients. Retrospective cohort study and detailed chart review for 431 consecutive PICCs and 141 CICVCs placed in patients under neurological intensive care from March 2008 through February 2010. Cumulative incidence of CRLVT, CLABSI, and line insertion-related complications were compared between PICC and CICVC groups. Risk factors for CRLVT including mannitol therapy during dwell time, previous history of venous thromboembolism, surgery longer than 1h during dwell time, and line placement in a paretic arm were also compared between groups. During the study period, 431 unique PICCs were placed with cumulative incidence of symptomatic thrombosis of 8.4%, CLABSI 2.8%, and line insertion-related complications 0.0%. During the same period, 141 unique CICVCs were placed with cumulative incidence of symptomatic thrombosis of 1.4%, CLABSI 1.4%, and line insertion-related complications 0.7%. There was a statistically significant difference in CRLVT with no difference in CLABSI or line insertion-related complications. In neurological critical care patients, CICVCs appear to have a better risk profile compared to PICCs, with a decreased risk of CRLVT. As use of PICCs in critical care patients increases, a prospective randomized trial comparing PICCs and CICVCs in neurological critical care patients is necessary to assist in choosing the appropriate catheter and to minimize risks of morbidity and mortality associated with central venous access. Copyright © 2012 Elsevier B.V. All rights reserved.
Lee, Jiwon; Kim, Won Ho; Ryu, Ho-Geol; Lee, Hyung-Chul; Chung, Eun-Jin; Yang, Seong-Mi; Jung, Chul-Woo
2017-08-01
We previously demonstrated the usefulness of milrinone for living donor hepatectomy. However, a less-invasive alternative to central venous catheterization and perioperative contributors to good surgical outcomes remain undetermined. The current study evaluated whether the stroke volume variation (SVV)-guided method can substitute central venous catheterization during milrinone-induced profound vasodilation. We randomly assigned 42 living liver donors to receive either SVV guidance or central venous pressure (CVP) guidance to obtain milrinone-induced low CVP. Target SVV of 9% was used as a substitute for CVP of 5 mm Hg. The surgical field grade evaluated by 2 attending surgeons on a 4-point scale was compared between the CVP- and SVV-guided groups (n = 19, total number of scores = 38 per group) as a primary outcome variable. Multivariable analysis was performed to identify independent factors associated with the best surgical field as a post hoc analysis. Surgical field grades, which were either 1 or 2, were not found to be different between the 2 groups via Mann-Whitney U test (P = .358). There was a very weak correlation between SVV and CVP during profound vasodilation such as CVP ≤ 5 mm Hg (R = -0.06; 95% confidence interval, -0.09 to -0.04; P < .001). Additional post hoc analysis suggested that younger age, lower baseline CVP, and longer duration of milrinone infusion might be helpful in providing the best surgical field. Milrinone-induced vasodilation resulted in favorable surgical environment regardless of guidance methods of low CVP during living donor hepatectomy. However, SVV was not a useful indicator of low CVP because of very weak correlation between SVV and CVP during profound vasodilation. In addition, factors contributing to the best surgical field such as donor age, proactive fasting, and proper dosing of milrinone need to be investigated further, ideally through prospective studies.
Catheter-related bloodstream infection.
Goede, Matthew R; Coopersmith, Craig M
2009-04-01
Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.
1991-01-01
central venous catheter is inserted into the bloodstream, a fibrin sheath forms around the cannula which attracts bacteria . Bacteria can either migrate from...to the fibrin sheath. After colonization of the fibrin sheath, the bacteria replicate and are released into the bloodstream when symptoms may develop...culture." Rose et al. (1988, p. 511) defined catheter site infection as occurring when "cultures at the exit site are identical to bacteria found on
Jauch, K. W.; Schregel, W.; Stanga, Z.; Bischoff, S. C.; Braß, P.; Hartl, W.; Muehlebach, S.; Pscheidl, E.; Thul, P.; Volk, O.
2009-01-01
Catheter type, access technique, and the catheter position should be selected considering to the anticipated duration of PN aiming at the lowest complication risks (infectious and non-infectious). Long-term (>7–10 days) parenteral nutrition (PN) requires central venous access whereas for PN <3 weeks percutaneously inserted catheters and for PN >3 weeks subcutaneous tunnelled catheters or port systems are appropriate. CVC (central venous catheter) should be flushed with isotonic NaCl solution before and after PN application and during CVC occlusions. Strict indications are required for central venous access placement and the catheter should be removed as soon as possible if not required any more. Blood samples should not to be taken from the CVC. If catheter infection is suspected, peripheral blood-culture samples and culture samples from each catheter lumen should be taken simultaneously. Removal of the CVC should be carried out immediately if there are pronounced signs of local infection at the insertion site and/or clinical suspicion of catheter-induced sepsis. In case PN is indicated for a short period (max. 7–10 days), a peripheral venous access can be used if no hyperosmolar solutions (>800 mosm/L) or solutions with a high titration acidity or alkalinity are used. A peripheral venous catheter (PVC) can remain in situ for as long as it is clinically required unless there are signs of inflammation at the insertion site. PMID:20049083
A survey of the use of ultrasound guidance in internal jugular venous cannulation.
McGrattan, T; Duffty, J; Green, J S; O'Donnell, N
2008-11-01
It has been that suggested the use of two dimensional (2D) ultrasound to facilitate placement of central venous cannulae in the internal jugular vein improves patient safety and reduces complications. Since the introduction of the National Institute for Clinical Excellence Technology Appraisal Guideline Number 49 in 2002, promoting the use of ultrasound in placement of internal jugular venous cannulae, utilisation of ultrasound has increased throughout the United Kingdom. We report the findings of a postal survey of 2000 senior anaesthetists in the United Kingdom which enquired about their use of ultrasound for internal jugular vein cannulae placement. Only 27% use 2D ultrasound as their first choice technique, although 35% use it as their first choice when teaching. There was no significant difference in practice between those working within a sub specialty in anaesthesia. There continues to be discrepancies between the application of the guideline and how senior anaesthetists both site and teach the placement of internal jugular vein central venous cannulae.
Development of Needle Insertion Manipulator for Central Venous Catheterization
NASA Astrophysics Data System (ADS)
Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.
Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.
NASA Technical Reports Server (NTRS)
Kirsch, K.
1981-01-01
A Spacelab experiment is described which proposes to obtain data on the degree of engorgement of the cephalad circulation during weightlessness by recording central venous pressure. Of practical importance is the question of how close the astronauts are to pulmonary edema and whether the pressure falls toward normal during the time of the mission. Another experiment to investigate deviations from normal fluid and mineral metabolism, possibly initiated by the central engorgement of the low pressure system, is discussed. Hormones responsible for the control of water and mineral balance (vasopressin, catecholamines, renin, aldosterone, corticosteroids, and prostaglandin E1) will be analyzed from blood samples.
Aydın, Kutlay; Tokur, Murat Emre; Ergan, Begüm
2018-01-01
A persistent left-sided superior vena cava (PLSVC) is the most frequent abnormality of the venous system; however, it is not a very well-known variation among physicians. Herein we report the case of a patient with a PLSVC who was diagnosed after central venous catheterization (CVC). An 80-year-old man was admitted to the emergency room with cardiopulmonary arrest. After the return of spontaneous circulation, CVC was blindly performed from the left jugular vein without any complications. However, routine chest X-ray after catheterization revealed that the catheter was moving down directly to the left heart. Thoracic computed tomography showed the right brachiocephalic vein draining into the left brachiocephalic vein and forming the left superior vena cava in front of the aortic arch. The left superior vena cava merged into the right atrium after crossing the left pulmonary artery. CVC is widely used in clinical practice, and therefore clinicians should be aware of possible variations in central veins, particularly during blind catheterization.
Central venous catheterization for parenteral nutrition.
Padberg, F T; Ruggiero, J; Blackburn, G L; Bistrian, B R
1981-01-01
To define the risks associated with central venous catheterization for total parenteral nutrition (TPN) 3291 patient days of this therapy, delivered by an established nutrition support team, were evaluated. One hundred and seventy-five catheters placed in 104 patients were reviewed over an 18 month period. Positive cultures were reported on 11 cannulae for a 6.4% incidence of colonization; five catheters (2.8%) were considered septic. Pleural or mediastinal complications of subclavian or internal jugular venipuncture occurred in eight patients (4.8%). Misdirection of the catheter tip occurred in 11.5% of insertions. Five patients (4.8%) had clinically apparent thrombosis in the superior vena cava, innominate and/or subclavian veins during hospitalization; four others had evidence of thrombosis at autopsy examination, giving an incidence of 8.7% in the entire series. No death directly resulted from the use of this therapy. Compliance with a rigid protocol by an experienced team can allow safe and effective use of central venous catheters and parenteral nutrition therapy. PMID:6782956
Meeder, Annelijn M; van der Steen, Marijke S; Rozendaal, Annemieke; van Zanten, Arthur R H
2016-10-03
This case report series describes 3 cases of cisatracurium besylate associated phlebitis after an infusion period of 14-20 hours. No similar cases have been reported in the literature. Association of phlebitis with another neuromuscular blocking agent, atracurium, has been described in the literature. The acidity of atracurium is thought to be the main cause. It is recommended that atracurium is administered only via central venous catheters when indicated to infuse over prolonged periods of time due to the acidity. Cisatracurium is a stereoisomer of atracurium and as such has the same molecular weight. Although cisatracurium also has a similar acidity as atracurium, a recommendation concerning infusion via a central venous catheter is lacking. We suggest prolonged administration of cisatracurium besylate only via centrally placed venous catheters or if not possible to careful monitor relevant peripheral intravenous sites to diminish the risks of phlebitis and associated complications or other cutaneous reactions. 2016 BMJ Publishing Group Ltd.
Fadoo, Zehra; Nisar, Muhammad I; Iftikhar, Raza; Ali, Sajida; Mushtaq, Naureen; Sayani, Raza
2015-10-01
Peripherally inserted central venous catheters (PICC) have been successfully used to provide central access for chemotherapy and frequent transfusions. The purpose of this study was to assess the feasibility of PICCs and determine PICC-related complications in pediatric hematology/oncology patients in a resource-poor setting. All pediatric patients (age below 16 y) with hematologic and malignant disorders who underwent PICC line insertion at Aga Khan University Hospital from January 2008 to June 2010 were enrolled in the study. Demographic features, primary diagnosis, catheter days, complications, and reasons for removal of device were recorded. Total of 36 PICC lines were inserted in 32 pediatric patients. Complication rate of 5.29/1000 catheter days was recorded. Our study showed comparable complication profile such as infection rate, occlusion, breakage, and dislodgement. The median catheter life was found to be 69 days. We conclude that PICC lines are feasible in a resource-poor setting and recommend its use for chemotherapy administration and prolonged venous access.
Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon
2016-12-01
The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.
Du, Wei; Liu, Da-Wei; Wang, Xiao-Ting; Long, Yun; Chai, Wen-Zhao; Zhou, Xiang; Rui, Xi
2013-12-01
Central venous oxygen saturation (Scvo2) is a useful therapeutic target when treating septic shock. We hypothesized that combining Scvo2 and central venous-to-arterial partial pressure of carbon dioxide difference (△Pco2) may provide additional information about survival. We performed a retrospective analysis of 172 patients treated for septic shock. All patients were treated using goal-directed therapy to achieve Scvo2 ≥ 70%. After 6 hours of treatment, we divided patients into 4 groups based on Scvo2 (<70% or ≥ 70%) and △Pco2 (<6 mm Hg or ≥ 6 mm Hg). Overall, 28-day mortality was 35.5%. For patients in whom the Scvo2 target was not achieved at 6 hours, mortality was 50.0%, compared with 29.5% in those in whom Scvo2 exceeded 70% (P = .009). In patients with Scvo2 ≥ 70%, mortality was lower if △Pco2 was <6 mm Hg than if △Pco2 was ≥ 6 mm Hg (56.1% vs 16.1%, respectively; P < .001) and 6-hour lactate clearance was superior (0.01 ± 0.61 vs 0.21 ± 0.31, respectively; P = .016). The combination of Scvo2 and △Pco2 appears to predict outcome in critically ill patients resuscitated from septic shock better than Scvo2 alone. Patients who meet both targets appear to clear lactate more efficiently. © 2013.
Central Vein Dilatation Prior to Concomitant Port Implantation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krombach, Gabriele A., E-mail: krombach@rad.rwth-aachen.de; Plumhans, Cedric; Goerg, Fabian
2010-04-15
Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker andmore » occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.« less
Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage
NASA Astrophysics Data System (ADS)
Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.
2014-03-01
Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.
Lichtenstern, C; Koch, C; Röhrig, R; Rosengarten, B; Henrich, M; Weigand, M A
2012-10-01
Early goal-directed hemodynamic optimization has become a cornerstone of sepsis therapy. One major defined goal is to achieve adequate central venous oxygen saturation (SO(2)). This study aimed to investigate the correlation between central venous SO(2) and frontal cerebral near-infrared spectroscopy (NIRS) measurement in patients with severe sepsis and septic shock. The NIRS method provides non-invasive measurement of regional oxygen saturation (rSO(2)) in tissues approximately 2 cm below the optical NIRS sensors which depends on arterial, capillary and venous blood. Thus this system gives site-specific real-time data about the balance of oxygen supply and demand. This was a secondary analysis from a prospective study of surgical intensive care (ICU) patients in the early phase of severe sepsis or septic shock. Bilateral cerebral rSO(2), central venous SO(2), arterial oxygen saturation (S(a)O(2)) and other surrogate parameters of oxygen supply, such as hemoglobin, partial pressure of oxygen and oxygen content in arterial blood were recorded. A total of 16 ICU patients (4 women, median age 65.5 years) were included in the study. As sepsis focus an intra-abdominal infection was detected in 62.5 % of patients, severe pneumonia was determined in 31.3 % and skin and soft tissue infections were recognized in 12.5 %. At study inclusion 50 % of patients had septic shock, the median sequential organ failure assessment (SOFA) score was 10.2 (interquartile range 5.25-8.75) and the median acute physiology and chronic health evaluation II (APACHE II) score was 26 (range 23.25-29.75). Mortality at day 28 was 37.5 %. Minimum rSO(2) (median 58) and right-sided rSO(2) (median 58) values showed a significant correlation in the analysis of receiver operating characteristics (area under the curve 0.844, p= 0.045). A central venous SO(2)< 70 % was indicated by rSO(2)< 56.5 with sensitivity and specificity of 75 % and 100 %, respectively. Cerebral NIRS could provide a fast and easily available side effect-free monitoring that could be used in addition to established procedures for goal-directed treatment in the early phase of sepsis. Further studies should be made in a larger population to verify the correlation found and to investigate the impact of NIRS-directed resuscitation treatment in early sepsis.
Forbes, Thomas L; Harris, Jeremy R; Kribs, Stewart W
2012-06-01
The debate regarding the possible link between chronic cerebrospinal venous insufficiency and multiple sclerosis (MS) is continuously becoming more and more contentious due to the current lack of level 1 evidence from randomized trials. Regardless of this continued uncertainty surrounding the safety and efficacy of this therapy, MS patients from Canada, and other jurisdictions, are traveling abroad to receive central venous angioplasty and, unfortunately, some also receive venous stents. They often return home with few instructions regarding follow-up or medical therapy. In response we propose some interim, practical recommendations for post-procedural surveillance and medical therapy, until further information is available.
Buchman, A L; Pickett, M J; Mann, L; Ament, M E
1993-01-01
We report the first case of a central venous catheter infection caused by Moraxella osloensis, which was successfully treated without catheter removal. The isolation, identification, and pathogenesis of this species are discussed. It is recommended that Moraxella isolates be identified to species in order to determine the relative pathogenic and opportunistic roles of the various Moraxella species. Our case also demonstrates that catheter sepsis caused by some Gram-negative organisms may be amenable to systemic antibiotic therapy without the necessity of catheter removal.
2012-01-01
Once the swine were anesthetized, left cervical cut downs were performed and a central venous polyethylene catheter was inserted into the external...open and the liver injury will be examined for evidence of re-bleeding. The venous and arterial pressures at which re-bleeding occur will be...Fig. 1) Figure 1. Clamp used for the pig liver injury model The clamp is placed centrally in the liver and it produces laceration of 1
Puiggròs, C; Cuerda, C; Virgili, N; Chicharro, M L; Martínez, C; Garde, C; de Luis, D
2012-01-01
In adult home parenteral nutrition (HPN) programme patients up to now no evidence-based recommendations exist on the central venous catheter maintenance nor venous thrombosis prevention. The use of heparin flushes could be linked with long term complications, besides, anticoagulants use is controversial. To be aware of the usual maintenance practice for HPN central venous catheters, catheter occlusion and related venous thrombosis incidence in our country. Retrospective study of active HPN patients older than 18 years registered by the NADYA- SENPE working group until November 2008. 49 patients were registered (16 males and 33 females), with an average age of 52.1 ± 13.9 years, belonging to 6 hospitals. HPN length was 57.4 ± 73.3 months with 5.8 ± 1.8 PN days a week. The most frequent pathologies were actinic enteritis, intestinal motility disorders and mesenteric ischemia (20.4% each), and neoplasm (16.3%). The reason for HPN provision was short bowel syndrome (49.0%), and intestinal obstruction (28.6%). Neoplasm (16.3%), thrombotic diathesis, thromboembolic syndrome and bed rest (6.1% each) were the main venous thrombosis adjuvant factors. Tunnelled catheters were used in 77.6% of patients, with implanted port-catheters in the remainder. Maintenance of the line was done with saline solution flushes (28.6%) and different concentrations of heparin solutions (69.4%). When heparin was used, it was removed before PN infusion in 63.3% of patients. Catheter occlusion and venous thrombotic events rates were 0.061/10³ and 0.115/10³ HPN days respectively. Eleven patients (22.4%) were treated with anticoagulant drugs due to previous episodes of venous thrombosis or pulmonary embolism. [corrected] The incidence of catheter related thrombotic complications incidence is low in this group of patients on HPN. There is a great variety of practices focused on the prevention of both: line occlusion and catheter related venous thrombosis. In conclusion, it would be necessary to standardize practice.
Systemic venous drainage: can we help Newton?
Corno, Antonio F
2007-06-01
In recent years substantial progress occurred in the techniques of cardiopulmonary bypass, but the factor potentially limiting the flexibility of cardiopulmonary bypass remains the drainage of the systemic venous return. In the daily clinical practice of cardiac surgery, the amount of systemic venous return on cardiopulmonary bypass is directly correlated with the amount of the pump flow. As a consequence, the pump flow is limited by the amount of venous return that the pump is receiving. On cardiopulmonary bypass the amount of venous drainage depends upon the central venous pressure, the height differential between patient and inlet of the venous line into the venous reservoir, and the resistance in the venous cannula(s) and circuit. The factors determining the venous return to be taken into consideration in cardiac surgery are the following: (a) characteristics of the individual patient; (b) type of planned surgical procedure; (c) type of venous cannula(s); (d) type of circuit for cardiopulmonary bypass; (e) strategy of cardiopulmonary bypass; (f) use of accessory mechanical systems to increased the systemic venous return. The careful pre-operative evaluation of all the elements affecting the systemic venous drainage, including the characteristics of the individual patient and the type of required surgical procedure, the choice of the best strategy of cardiopulmonary bypass, and the use of the most advanced materials and tools, can provide a systemic venous drainage substantially better than what it would be allowed by the simple "Law of universal gravitation" by Isaac Newton.
A New Technique for Femoral Venous Access in Infants Using Arterial Injection Venous Return Guidance
Ebishima, Hironori; Kitano, Masataka; Kurosaki, Kenichi; Shiraishi, Isao
2017-01-01
Objectives: Although venography guidance is helpful for central venous catheter placement, it is sometimes difficult to place a peripheral intravenous cannula for enhancement. We designed a new technique for establishing femoral venous access using venography guidance in the return phase of peripheral arteriography. This new technique was named arterial injection venous return guidance. Here we assessed the efficacy and safety of arterial injection venous return guidance. Methods: We reviewed data of 29 infants less than 6 months old undergoing catheter intervention at our institute in 2014. Of the 29 patients, femoral venous cannulation was performed using arterial injection venous return guidance in 5 patients, venography in 20 patients, and the landmark method in 4 patients. The technical success rates and incidence of complications were compared. Results: The overall success rates were 100% in the arterial injection venous return-guided and venography-guided groups. The mean procedure duration and mean contrast material injection time were similar between the groups. The contrast effect on the femoral vein in the arterial injection venous return-guided group was lower than that in the venography-guided group, but adequate for surgery. The overall complication rate was 17%, and obstruction of previously placed intravenous catheters was the most common complication. Conclusions: Therefore, the arterial injection venous return guidance technique was as safe and efficient as venography for establishing venous access. PMID:29034015
Catalano, Orlando; de Lutio di Castelguidone, Elisabetta; Sandomenico, Claudia; Petrillo, Mario; Aprea, Pasquale; Granata, Vincenza; D'Errico, Adolfo Gallipoli
2011-03-01
Venous thrombosis is a common occurrence in cancer patients, developing spontaneously or in combination with indwelling central venous devices (CVD). To analyze the multidetector CT (MDCT) prevalence, appearance, and significance of catheter-related thoracic venous thrombosis in oncologic patients and to determine the percentage of thrombi identified in the original reports. Five hundred consecutive patients were considered. Inclusion criteria were: presence of a CVD; availability of a contrast-enhanced MDCT; and cancer history. Exclusion criteria were: direct tumor compression/infiltration of the veins; poor image quality; device tip not in the scanned volume; and missing clinical data. Seventeen (3.5%) out of the final 481 patients had a diagnosis of venous thrombosis. Factors showing the highest correlation with thrombosis included peripherally-inserted CVD, right brachiocephalic vein tip location, patient performance status 3, metastatic stage disease, ongoing chemotherapy, and longstanding CVD. The highest prevalence was in patients with lymphoma, lung carcinoma, melanoma, and gynecologic malignancies. Eleven out of 17 cases had not been identified in the original report. CVD-related thrombosis is not uncommon in cancer patients and can also be observed in outpatients with a good performance status and a non-metastatic disease. Thrombi can be very tiny. Radiologists should be aware of the possibility to identify (or overlook) small thrombi.
[Paget-Schroetter síndrome associated with hyperhomocsyteinemia].
González, C I; Cires, M; Rubio, T; Jiménez, F; Sarasíbar, E; Gaztelu, M T; González, V
2007-01-01
Venous thromboembolic disease (VTED) in the upper extremities is an infrequent entity, although its incidence has increased in relation to the use of central venous catheters. Its etiology can be primary (idiopathic, spontaneous, due to effort or traumatic) or secondary (related to tumours, central venous catheters, etc.). We present a case of primary venous thrombosis of the upper right extremity, also called the Paget-Schroetter syndrome. This clinical picture is usually associated with intensive and/or repetitive exercise or effort of the affected extremity, anatomical alterations in the zone, or it can be the first manifestation of a previously unknown thrombophilic state, as in the case that concerns us. The clinical picture usually consists of pain in the affected extremity, frequently accompanied by edema and collateral circulation. Echography-Doppler frequently presents false negatives, and it is recommendable to carry out CAT, due to its greater specificity and for evaluating the neighbouring structures, although flebography continues to be the cardinal test for diagnosing this picture. There is no unanimity of opinion concerning treatment, and it is recommendable that this should be individualised in accordance with the characteristics of each case.
Kumar, Dharmendra; Ahmed, Syed Moied; Ali, Shahna; Ray, Utpal; Varshney, Ankur; Doley, Kashmiri
2015-11-01
Central venous pressure (CVP) assesses the volume status of patients. However, this technique is not without complications. We, therefore, measured peripheral venous pressure (PVP) to see whether it can replace CVP. To evaluate the correlation and agreement between CVP and PVP after passive leg raise (PLR) in critically ill patients on mechanical ventilation. Prospective observational study in Intensive Care Unit. Fifty critically ill patients on mechanical ventilation were included in the study. CVP and PVP measurements were taken using a water column manometer. Measurements were taken in the supine position and subsequently after a PLR of 45°. Pearson's correlation and Bland-Altman's analysis. This study showed a fair correlation between CVP and PVP after a PLR of 45° (correlation coefficient, r = 0.479; P = 0.0004) when the CVP was <10 cmH2O. However, the correlation was good when the CVP was >10 cmH2O. Bland-Altman analysis showed 95% limits of agreement to be -2.912-9.472. PVP can replace CVP for guiding fluid therapy in critically ill patients.
Significance of Blunted Venous Waveforms Seen on Upper Extremity Ultrasound.
Pham, Xuan-Binh D; Ihenachor, Ezinne J; Wu, Hoover; Kim, Jerry J; Kaji, Amy H; Koopmann, Matthew C; Ryan, Timothy J; de Virgilio, Christian
2017-07-01
Current guidelines recommend vascular mapping ultrasound (US) prior to arteriovenous fistula creation. Blunted venous waveforms (BVWs) suggest central venous stenosis; however, this relationship and one between BVWs and the presence of a central venous catheter (CVC) remain unclear. All patients who received upper extremity vascular mapping US between January 2013 and October 2014 at a single institution were retrospectively reviewed. Patient demographics, comorbidities, US results, pacemaker history, and CVC status were collected. Waveforms were assessed at the proximal subclavian vein/distal axillary vein and interpreted by radiologists. Patients were determined to have central venous stenosis (CVS) if detected by venography within 6 months of US. There were 342 patients, of which 165 (48%) had a current CVC and 29 (8.5%) had BVW of at least 1 arm. Right-sided BVW were associated with a history of a prior ipsilateral CVC (odds ratio [OR] = 4.5, 95% confidence interval [CI] = 1.6-12.6, P = 0.009). Of the 342 patients, 69 (20%) had a venogram within 6 months. Seventeen (25%) of the 69 patients had CVS, with 7 involving the left subclavian vein, 8 the right subclavian vein, and 3 the superior vena cava (one patient had tandem stenoses). A BVW on the left side was not associated with any CVS. A BVW on the right side was associated with an ipsilateral CVS (OR = 5.8, 95% CI = 1.2-27.4, P = 0.04). This association persisted in the setting of a prior CVC (relative risk = 1.3, 95% CI = 0.9-2, P = 0.01). There are associations between right-sided BVW and an ipsilateral subclavian vein stenosis. We recommend that hemodialysis access planning includes venography to rule out central vein stenosis in patients with BVW, especially if right-sided and in the setting of a prior CVC. Copyright © 2017 Elsevier Inc. All rights reserved.
Hong, Sun; Seo, Tae-Seok; Song, Myung Gyu; Seol, Hae-Young; Suh, Sang Il; Ryoo, In-Seon
2018-06-01
To evaluate the clinical outcomes and complications of totally implantable venous access port implantation via the axillary vein in patients with head and neck malignancy. A total of 176 totally implantable venous access ports were placed via the axillary vein in 171 patients with head and neck malignancy between May 2012 and June 2015. The patients included 133 men and 38 women, and the mean age was 58.8 years (range: 19-84 years). Medical records were retrospectively reviewed. This study included a total of 93,237 totally implantable venous access port catheter-days (median 478 catheter-days, range: 13-1380 catheter-days). Of the 176 implanted totally implantable venous access port, complications developed in nine cases (5.1%), with the overall incidence of 0.097 events/1000 catheter-days. The complications were three central line-associated blood-stream infection cases, one case of keloid scar at the needling access site, and five cases of central vein stenosis or thrombosis on neck computed tomography images. The 133 cases for which neck computed tomography images were available had a total of 59,777 totally implantable venous access port catheter-days (median 399 catheter-days, range: 38-1207 catheter-days). On neck computed tomography evaluation, the incidence of central vein stenosis or thrombosis was 0.083 events/1000 catheter-days. Thrombosis developed in four cases, yielding an incidence of 0.067 events/1000 catheter-days. All four patients presented with thrombus in the axillary or subclavian vein. Stenosis occurred in one case yielding an incidence of 0.017 events/1000 catheter-days. One case was catheter-related brachiocephalic vein stenosis, and the other case was subclavian vein stenosis due to extrinsic compression by tumor progression. Of the nine complication cases, six underwent port removal. These data indicate that totally implantable venous access port implantation via the axillary vein in patients with head and neck malignancy is safe and feasible, with a low axillary vein access-related complication rate.
Benvenuti, Stefano; Ceresoli, Rosanna; Boroni, Giovanni; Parolini, Filippo; Porta, Fulvio; Alberti, Daniele
2018-03-01
The aim of our study was to present our experience with the use of peripherally inserted central catheters (PICCs) in pediatric patients receiving autologous or allogenic blood stem-cell transplantation. The insertion of the device in older children does not require general anesthesia and does not require a surgical procedure. From January 2014 to January 2017, 13 PICCs were inserted as a central venous device in 11 pediatric patients submitted to 14 autologous or allogeneic stem-cell transplantation, at the Bone Marrow Transplant Unit of the Children's Hospital of Brescia. The mean age of patients at the time of the procedure was 11.3 years (range 3-18 years). PICCs remained in place for an overall period of 4104 days. All PICCs were positioned by the same specifically trained physician and utilized by nurses of our stem-cell transplant unit. No insertion-related complications were observed. Late complications were catheter ruptures and line occlusions (1.2 per 1000 PICC days). No rupture or occlusion required removal of the device. No catheter-related venous thrombosis, catheter-related bloodstream infection (CRBSI), accidental removal or permanent lumen occlusion were observed. Indications for catheter removal were completion of therapy (8 patients) and death (2 patients). Three PICCs are currently being used for blood sampling in follow-up patients after transplantation. Our data suggest that PICCs are a safe and effective alternative to conventional central venous catheters even in pediatric patients with high risk of infectious and hemorrhagic complications such as patients receiving stem-cell transplantation.
Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary
2010-11-01
To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.
Wu, Alex; Helo, Naseem; Moon, Eunice; Tam, Matthew; Kapoor, Baljendra; Wang, Weiping
2014-01-01
Iatrogenic migration of inferior vena cava (IVC) filters is a potentially life-threatening complication that can arise during blind insertion of central venous catheters when the guide wire becomes entangled with the filter. In this study, we reviewed the occurrence of iatrogenic migration of IVC filters in the literature and assessed methods for preventing this complication. A literature search was conducted to identify reports of filter/wire entrapment and subsequent IVC filter migration. Clinical outcomes and complications were identified. A total of 38 cases of filter/wire entrapment were identified. All of these cases involved J-tip guide wires. Filters included 23 Greenfield filters, 14 VenaTech filters, and one TrapEase filter. In 18 cases of filter/wire entrapment, there was migration of the filter to the heart and other central venous structures. Retrieval of the migrated filter was successful in only four of the 18 cases, and all of these cases were complicated by strut fracture and distant embolization of fragments. One patient required resuscitation during retrieval. Successful disengagement was possible in 20 cases without filter migration. Iatrogenic migration of an IVC filter is an uncommon complication related to wire/filter entrapment. This complication can be prevented with knowledge of the patient's history, use of proper techniques when placing a central venous catheter, identification of wire entrapment at an early stage, and use of an appropriate technique to disengage an entrapped wire. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Pérez-Granda, María Jesús; Guembe, María; Cruces, Raquel; Barrio, José María; Bouza, Emilio
2016-02-02
Culture of catheter hubs and skin surrounding the catheter entry site has a negative predictive value for catheter tip colonization. However, manipulation of the hub for culture requires the hubs to be swabbed, introducing potential dislodging of biofilm and subsequent migration of microorganisms. Hubs are usually closed with needleless connectors (NCs), which are replaced regularly. Our objective was to evaluate whether culture of flushed withdrawn NCs is an alternative to hub culture when investigating central venous catheter colonization. The study population comprised 49 intensive care unit patients whose central venous catheters had been in place for at least 7 days. Cultures of NCs and skin were obtained weekly. We included 82 catheters with more than 7 days' indwelling time. The catheter tip colonization rate was 18.3% (15/82). Analysis of skin and NC cultures revealed a 92.5% negative predictive value for catheter colonization. Three episodes of catheter-related bloodstream infection (C-RBSI) occurred in patients with colonized catheters. Surveillance of NC and skin cultures could help to identify patients at risk for C-RBSI.
Yates, Kenneth; Sullivan, Maura; Clark, Richard
2012-01-01
Cognitive task analysis (CTA) methods were used for 2 surgical procedures to determine (1) the extent that experts omitted critical information, (2) the number of experts required to capture the optimalamount of information, and (3) the effectiveness of a CTA-informed curriculum. Six expert physicians for both the central venous catheter placement and open cricothyrotomy were interviewed. The transcripts were coded, corrected, and aggregated as a "gold standard." The information captured for each surgeon was then analyzed against the gold standard. Experts omitted an average of 34% of the decisions for the central venous catheter and 77% of the decisions for the Cric. Three to 4 experts were required to capture the optimal amount of information. A significant positive effect on performance (t([21]) = 2.08, P = .050), and self-efficacy ratings (t([18]) = 2.38, P = .029) were found for the CTA-informed curriculum for cricothyrotomy. CTA is an effective method to capture expertise in surgery and a valuable component to improve surgical training. Copyright © 2012 Elsevier Inc. All rights reserved.
Prevention of catheter-related blood stream infection.
Byrnes, Matthew C; Coopersmith, Craig M
2007-08-01
Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.
Peripheral intravenous nutrition without fat in neonatal surgery.
Coran, A G; Weintraub
1977-04-01
During a 1 yr period, 19 infants less than 2 mo of age were fed intravenously with an infusate composed of glucose, amino acids, electrolytes, and vitamins. The solution was infused at a rate of 200 ml/kg/day or more for periods ranging from 5-247 days. No central venous catheters were utilized; the solutions were always administered through a needle in a peripheral vein. Weight gains similar to those seen with other techniques of intravenous nutrition were observed in all of the patients studied. No instance of fluid overload in the form of pulmonary edema, peripheral edema, or congestive heart failure was seen, and osmotic diuresis was not observed because of the lower tonicity of the infusate. Phlebitis was seen in 1/5 of the infusions, but was reversed by stopping the infusion and applying warm soaks. Three cases of skin slough were observed and two of these healed spontaneously without the need of skin grafting. The advantages of this technique over central venous nutrition are the elimination of the complications related to the central venous catheter, namely, sepsis and superior vena cava thrombosis.
[Disposable nursing applicator-pocket of indwelling central venous catheter].
Wei, Congli; Ma, Chunyuan
2017-11-01
Catheter related infection is the most common complication of central venous catheter, which pathogen mainly originate from the pipe joint and the skin around puncture site. How to prevent catheter infection is an important issue in clinical nursing. The utility model disclosed a "disposable nursing applicator-pocket of indwelling central venous catheter", which is mainly used for the fixation and the protection. The main structure consists of two parts, one is medical applicator to protect the skin around puncture site, and the other is gauze pocket to protect the catheter external connector. When in use, the catheter connector is fitted into the pocket, and then the applicator is applied to cover the puncture point of the skin. Integrated design of medical applicator and gauze pocket was designed to realize double functions of fixation and protection. The disposable nursing applicator-pocket is made of medical absorbent gauze (outer layer) and non-woven fabric (inner layer), which has the characteristics of comfortable, breathable, dust filtered, bacteria filtered, waterproof, antiperspirant and anti-pollution. The utility model has the advantages of simple structure, low cost, simple operation, effective protection, easy realization and popularization.
Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S
2016-05-01
To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Human cerebral venous outflow pathway depends on posture and central venous pressure
Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M
2004-01-01
Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348
Veronesi, Marco; Mancini, Elena; Salvati, Filippo; Santoro, Antonio
2011-01-01
A 67-year-old woman with end-stage renal disease (polycystic kidney disease) who had been on dialysis for 10 years came to our department for a second opinion about upper left arm edema homolateral to the arteriovenous fistula (AVF). Because of the suspicion of venous stenosis she had already been submitted to angiographic examination of the AVF which, however, did not show any occlusive process. In addition to the kidney problem, the clinical history included dilated cardiomyopathy, and 2 years earlier a biventricular implantable cardioverter defibrillator (ICD) had been placed. The patient had never had a central venous catheter (CVC). She presented a typical superior vena cava syndrome picture with arm, neck and hemifacial edema and superficial cutaneous venous reticulum. The venous pressure during extracoroporeal circulation was high and blood recirculation was documented. Angio-CT was performed to look for a compressive process in the chest, but this was excluded. We then performed a new trans-AVF angiography to study extensively the axillary-subclavian-superior vena cava district. At first, no stenosis or thrombosis was observed, but the presence of ICD and its leads (left-sided implanted) in the anonymous vein created obstacles to diagnosis. Repeated injections of contrast medium and focusing imaging on the leads route allowed us to highlight a venous stenosis in the anonymous vein. Transluminal angioplasty was successfully carried out during the same procedure. 1) In hemodialysis patients the appearance of signs of intrathoracic vein drainage obstacles is not always associated with previous CVC implantation; 2) in the hemodialysis patient, any device (PM, ICD) should be implanted contralaterally to the fistula arm in order to avoid the risk that a venous stenosis may cause AVF dysfunction.
Konstantinou, Evangelos A; Stafylarakis, Emmanuil; Kapritsou, Maria; Mitsos, Aristotelis P; Fotis, Theofanis G; Kiekkas, Panagiotis; Mariolis-Sapsakos, Theodoros; Argyras, Eriphyli; Nomikou, Irini Th; Dimitrakopoulos, Antonios
2012-09-01
Placement of peripherally inserted central catheters (PICCs), definitely offers a clear advantage over any other method regarding central venous catheterization. Its ultrasonographic orientation enhances significantly its accuracy, safety and efficacy, making this method extremely comfortable for the patient who can continue his or her therapy even in an outpatient basis. We present the first reported case of a PICCS insertion in Greece, which has been performed by a university-degree nurse. The aim of this review of literature was to present the evolution in nursing practice in Greece. A PICC was inserted in a 77-year-old male patient suffering from a recent chemical pneumonia with a history of Alzheimer's disease. A description of all the technical details of this insertion is reported, focusing on the pros and cons of the method and a thorough review of the history and advances in central venous catheterization throughout the years is also presented. PICCs provide long-term intravenous access and facilitate the delivery of extended antibiotic therapy, chemotherapy and total parenteral nutrition. We strongly believe that PICCs are the safest and most effective method of peripherally inserted central venous catheterization. Larger series are necessary to prove the above hypothesis, and they are under construction by our team. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.
[Venous thrombosis of atypical location in patients with cancer].
Campos Balea, Begoña; Sáenz de Miera Rodríguez, Andrea; Antolín Novoa, Silvia; Quindós Varela, María; Barón Duarte, Francisco; López López, Rafael
2015-01-01
Venous thromboembolism (VTE) is a complication that frequently occurs in patients with neoplastic diseases. Several models have therefore been developed to identify patient subgroups diagnosed with cancer who are at increased risk of developing VTE. The most common forms of thromboembolic episodes are deep vein thrombosis in the lower limbs and pulmonary thromboembolism. However, venous thrombosis is also diagnosed in atypical locations. There are few revisions of unusual cases of venous thrombosis. In most cases, VTE occurs in the upper limbs and in the presence of central venous catheters, pacemakers and defibrillators. We present the case of a patient diagnosed with breast cancer and treated with surgery, chemotherapy and radiation therapy who developed a thrombosis in the upper limbs (brachial and axillary). Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Detection of an embolized central venous catheter fragment with endobronchial ultrasound.
Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L
2018-01-01
An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.
1998-06-01
Infusion Blood Products • 248 Force Fluids • • 064 Venous Cutdown • 263 Partial Bath (Assisted) • • 065 Insert Central Venous Lines • 267 Linen Change...which are further complicated by inadequate patient histories , diagnostic tools, and logistic support. Timely and appropriate treatment may...Appropriate Medication • 011 Stabilize Cervical • • 148 Obtain Specimen for Lab Analysis • • 017 Suction (Oral/Trach/Endo) • • 149 Blood Drawing Venous
Nowak-Göttl, Ulrike; Kenet, Gili; Mitchell, Lesley G
2009-03-01
Acute lymphoblastic leukaemia (ALL) is the most common malignancy associated with venous thromboembolism (VTE) in children. The prevalence of symptomatic VTE ranges from 0% to 36%, and the variation can be explained, at least in part, by differences in chemotherapeutic protocols. The mechanism for increased risk of VTE is associated with alterations in the haemostatic system by use of L-asparaginase (ASP) alone or in combination with vincristine or prednisone, presence of central venous lines (CVLs) and/or inherited thrombophilia. The children at greatest risk are generally those receiving Escherichia coli ASP concomitant with prednisone. The majority of symptomatic VTEs occur in the central nervous system or in the upper venous system. In the majority of cases, asymptomatic VTEs are associated with CVLs. External CVLs are affected more often than internal CVLs. Evidence-based guidelines on prevention and treatment guidelines for ALL-related VTE are lacking, and carefully designed clinical trials are needed urgently.
Central venous catheterization training: current perspectives on the role of simulation
Soffler, Morgan I; Hayes, Margaret M; Smith, C Christopher
2018-01-01
Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC) is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions. PMID:29872360
Central venous catheterization training: current perspectives on the role of simulation.
Soffler, Morgan I; Hayes, Margaret M; Smith, C Christopher
2018-01-01
Simulation is a popular and effective training modality in medical education across a variety of domains. Central venous catheterization (CVC) is commonly undertaken by trainees, and carries significant risk for patient harm when carried out incorrectly. Multiple studies have evaluated the efficacy of simulation-based training programs, in comparison with traditional training modalities, on learner and patient outcomes. In this review, we discuss relevant adult learning principles that support simulation-based CVC training, review the literature on simulation-based CVC training, and highlight the use of simulation-based CVC training programs at various institutions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tercan, Fahri; Oguzkurt, Levent; Ozkan, Ugur
2008-05-15
The purpose of this study was to compare the technical success and complication rates of ultrasonography-guided central venous catheterization between adult and pediatric patients which have not been reported previously. In a 4-year period, 859 ultrasonography-guided central vein catheterizations in 688 adult patients and 247 catheterizations in 156 pediatric patients were retrospectively evaluated. Mean age was 56.3 years (range, 18 to 95 years) for adults and 3.3 years (range, 0.1 to 16.3 years) for children. The preferred catheterization site was internal jugular vein in 97% of adults and 85% of children. The technical success rate, mean number of punctures, andmore » rate of single wall puncture were 99.4%, 1.04 (range, 1-3), and 83% for adults and 90.3%, 1.25 (range, 1-5), and 49% for children, respectively. All the differences were statistically significant (p < 0.05). Complication rates were 2.3% and 2.4% for adults and children, respectively (p > 0.05). Major complications such as pneumothorax and hemothorax were not seen in any group. In conclusion, ultrasonography-guided central venous catheterization has a high technical success rate, lower puncture attempt rate, and higher single wall puncture rate in adults compared to children. Complication rates are comparable in the two groups.« less
Marnejon, Thomas; Angelo, Debra; Abu Abdou, Ahmed; Gemmel, David
2012-01-01
To identify clinically important risk factors associated with upper extremity venous thrombosis following peripherally inserted central venous catheters (PICC). A retrospective case control study of 400 consecutive patients with and without upper extremity venous thrombosis post-PICC insertion was performed. Patient data included demographics, body mass index (BMI), ethnicity, site of insertion, size and lumen of catheter, internal length, infusate, and co-morbidities, such as diabetes mellitus, congestive heart failure, and renal failure. Additional risk factors analyzed were active cancer, any history of cancer, recent trauma, smoking, a history of prior deep vein thrombosis, and recent surgery, defined as surgery within three months prior to PICC insertion. The prevalence of trauma, renal failure, and infusion with antibiotics and total parenteral nutrition (TPN) was higher among patients exhibiting upper extremity venous thrombosis (UEVT), when compared to controls. Patients developing UEVT were also more likely to have PICC line placement in a basilic vein and less likely to have brachial vein placement (P<.001). Left-sided PICC line sites also posed a greater risk (P=.026). The rate of standard DVT prophylaxis with low molecular weight heparin and unfractionated heparin and the use of warfarin was similar in both groups. Average length of hospital stay was almost double among patients developing UEVT, 19.5 days, when compared to patients undergoing PICC line insertion without thrombosis, 10.8 days (t=6.98, P<.001). In multivariate analysis, trauma, renal failure, left-sided catheters, basilic placement, TPN, and infusion with antibiotics, specifically vancomycin, were significant risk factors for UEVT associated with PICC insertion. Prophylaxis with low molecular weight heparin, unfractionated heparin or use of warfarin did not prevent the development of venous thrombosis in patients with PICCs. Length of hospital stay and cost are markedly increased in patients who develop PICC-associated upper extremity venous thrombosis.
Krivec, Bojan; Voga, Gorazd; Podbregar, Matej
2004-05-31
Patients with massive pulmonary embolism and obstructive shock usually require hemodynamic stabilization and thrombolysis. Little is known about the optimal and proper use of volume infusion and vasoactive drugs, or about the titration of thrombolytic agents in patients with relative contraindication for such treatment. The aim of the study was to find the most rapidly changing hemodynamic variable to monitor and optimize the treatment of patients with obstructive shock following massive pulmonary embolism. Ten consecutive patients hospitalized in the medical intensive care unit in the community General Hospital with obstructive shock following massive pulmonary embolism were included in the prospective observational study. Heart rate, systolic arterial pressure, central venous pressure, mean pulmonary-artery pressure, cardiac index, total pulmonary vascular-resistance index, mixed venous oxygen saturation, and urine output were measured on admission and at 1, 2, 3, 4, 8, 12, and 16 hours. Patients were treated with urokinase through the distal port of a pulmonary-artery catheter. At 1 hour, mixed venous oxygen saturation, systolic arterial pressure and cardiac index were higher than their admission values (31+/-10 vs. 49+/-12%, p<0.0001; 86+/-12 vs. 105+/-17 mmHg, p<0.01; 1.5+/-0.4 vs. 1.9+/-0.7 L/min/m2, p<0.05; respectively), whereas heart rate, central venous pressure, mean pulmonary-artery pressure and urine output remained unchanged. Total pulmonary vascular-resistance index was lower than at admission (29+/-10 vs. 21+/-12 mmHg/L/min/m2, p<0.05). The relative change of mixed venous oxygen saturation at hour 1 was higher than the relative changes of all other studied variables (p<0.05). Serum lactate on admission and at 12 hours correlated to mixed venous oxygen saturation (r=-0.855, p<0.001). In obstructive shock after massive pulmonary embolism, mixed venous oxygen saturation changes more rapidly than other standard hemodynamic variables.
Ooue, Anna; Sato, Kohei; Hirasawa, Ai; Sadamoto, Tomoko
2012-11-07
The superficial vein of the resting limb constricts sympathetically during exercise. Central command is the one of the neural mechanisms that controls the cardiovascular response to exercise. However, it is not clear whether central command contributes to venous vessel response during exercise. Tendon vibration during static elbow flexion causes primary muscle spindle afferents, such that a lower central command is required to achieve a given force without altering muscle force. The purpose of this study was therefore to investigate whether a reduction in central command during static exercise with tendon vibration influences the superficial venous vessel response in the resting limb. Eleven subjects performed static elbow flexion at 35% of maximal voluntary contraction with (EX + VIB) and without (EX) vibration of the biceps brachii tendon. The heart rate, mean arterial pressure, and rating of perceived exertion (RPE) in overall and exercising muscle were measured. The cross-sectional area (CSAvein) and blood velocity of the basilic vein in the resting upper arm were assessed by ultrasound, and blood flow (BFvein) was calculated using both variables. Muscle tension during exercise was similar between EX and EX + VIB. However, RPEs at EX + VIB were lower than those at EX (P <0.05). Increases in heart rate and mean arterial pressure during exercise at EX + VIB were also lower than those at EX (P <0.05). CSAvein in the resting limb at EX decreased during exercise from baseline (P <0.05), but CSAvein at EX + VIB did not change during exercise. CSAvein during exercise at EX was smaller than that at EX + VIB (P <0.05). However, BFvein did not change during the protocol under either condition. The decreases in circulatory response and RPEs during EX + VIB, despite identical muscle tension, showed that activation of central command was less during EX + VIB than during EX. Abolishment of the decrease in CSAvein during exercise at EX + VIB may thus have been caused by a lower level of central command at EX + VIB rather than EX. Diminished central command induced by tendon vibration may attenuate the superficial venous vessel response of the resting limb during sustained static arm exercise.
Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.
Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D
2017-08-01
Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.
Nakauchi, Kana; Kawazoe, Hitoshi; Miyajima, Risa; Waizumi, Chieko; Rokkaku, Yuki; Tsuneoka, Kikue; Higuchi, Noriko; Fujiwara, Mitsuko; Kojima, Yoh; Yakushijin, Yoshihiro
2015-11-01
Venous pain induced by oxaliplatin(L-OHP)is a clinical issue related to adherence to the Cape OX regimen. To prevent LOHP- induced venous pain, we provided nursing care to outpatients who were administered a preheated L -OHP diluted solution using a hot compress. We retrospectively evaluated the risk factors for colorectal cancer patients who had L -OHP induced phlebitis and venous pain. Furthermore, the preventive effect of nursing care was compared between inpatients and outpatients from January 2010 to March 2012. At the L-OHP administration site, any symptoms were defined as phlebitis, whereas pain was defined as venous pain. A total of 132 treatment courses among 31 patients were evaluated. Multivariate logistic regression analysis revealed that both phlebitis and venous pain were significantly more common in female patients (adjusted odds ratio, 2.357; 95%CI: 1.053-5.418; and adjusted odds ratio, 5.754; 95%CI: 2.119-18.567, respectively). The prevalence of phlebitis and venous pain did not differ between inpatients and outpatients (phlebitis, 61.3% vs 67.7%; venous pain, 29.0%vs 19.4%). These results suggest that administration of L-OHP via a central venous route should be considered in female patients.
Characterization of central venous catheter-associated deep venous thrombosis in infants.
Gray, Brian W; Gonzalez, Raquel; Warrier, Kavita S; Stephens, Lauren A; Drongowski, Robert A; Pipe, Steven W; Mychaliska, George B
2012-06-01
Deep venous thrombosis (DVT) is a frequent complication in infants with central venous catheters (CVCs). We performed this study to identify risk factors and risk-reduction strategies of CVC-associated DVT in infants. Infants younger than 1 year who had a CVC placed at our center from 2005 to 2009 were reviewed. Patients with ultrasonically diagnosed DVT were compared to those without radiographic evidence. Of 333 patients, 47% (155/333) had femoral, 33% (111/333) had jugular, and 19% (64/333) had subclavian CVCs. Deep venous thromboses occurred in 18% (60/333) of patients. Sixty percent (36/60) of DVTs were in femoral veins. Femoral CVCs were associated with greater DVT rates (27%; 42/155) than jugular (11%; 12/111) or subclavian CVCs (9%; 6/64; P < .01). There was a 16% DVT rate in those with saphenofemoral Broviac CVCs vs 83% (20/24) in those with percutaneous femoral lines (P < .01). Multilumen CVCs had higher DVT rates than did single-lumen CVCs (54% vs 6%, P < .01), and mean catheter days before DVT diagnosis was shorter for percutaneous lines than Broviacs (13 ± 17 days vs 30 ± 37 days, P = .02). Patients with +DVT had longer length of stay (86 ± 88 days vs 48 ± 48 days, P < .01) and higher percentage of intensive care unit admission (82% vs 70%, P = .02). Deep venous thrombosis reduction strategies in infants with CVCs include avoiding percutaneous femoral and multilumen CVCs, screening percutaneous lines, and early catheter removal. Copyright © 2012 Elsevier Inc. All rights reserved.
Madenci, Arin L; Solis, Carolina V; de Moya, Marc A
2014-02-01
Simulation training for invasive procedures may improve patient safety by enabling efficient training. This study is a meta-analysis with rigorous inclusion and exclusion criteria designed to assess the real patient procedural success of simulation training for central venous access. Published randomized controlled trials and prospective 2-group cohort studies that used simulation for the training of procedures involving central venous access were identified. The quality of each study was assessed. The primary outcome was the proportion of trainees who demonstrated the ability to successfully complete the procedure. Secondary outcomes included the mean number of attempts to procedural success and periprocedural adverse events. Proportions were compared between groups using risk ratios (RRs), whereas continuous variables were compared using weighted mean differences. Random-effects analysis was used to determine pooled effect sizes. We identified 550 studies, of which 5 (3 randomized controlled trials, 2 prospective 2-group cohort studies) studies of central venous catheter (CVC) insertion were included in the meta-analysis, composed of 407 medical trainees. The simulation group had a significantly larger proportion of trainees who successfully placed CVCs (RR, 1.09; 95% confidence interval [CI], 1.03-1.16, P<0.01). In addition, the simulation group had significantly fewer mean attempts to CVC insertion (weighted mean difference, -1.42; 95% CI, -2.34 to -0.49, P<0.01). There was no significant difference in the rate of adverse events between the groups (RR, 0.50; 95% CI, 0.19-1.29; P=0.15). Training programs should consider adopting simulation training for CVC insertion to improve the real patient procedural success of trainees.
Knowledge of nursing students about central venous catheters.
Mlinar, Suzana; Malnarsić, Rosanda Rasković
2012-04-01
Central venous catheters (CVC) are at the crucial importance, particulary in the intensive therapy units. In order to handle a CVC safely, nursing students need to acquire theoretical and practical knowledge during the course of their studies. The aim of the study was to establish theoretical knowledge of nursing students about the procedures of nurses in placing and removing a central venous catheter (CVC), dressing the catheter entry point, the reasons for measuring central venous pressure (CVP), possible complications and risk factors for developing infections related to CVC. The questionnaire developed specifically for this cross-sectionl study was handed out to 87 full-time students and 57 part-time students. The results show that all the surveyed nursing students know why chest radiography is carried out when inserting a catheter, have relatively good knowledge of CVC insertion points, procedures carried out in case of a suspected catheter sepsis and complications and risk factors for the development of infections related to CVC. However, the study show that the majority of students have insufficient knowledge of the procedures accompanying insertion of a catheter, signs that indicate correct functioning of CVC, frequency of flushing a catheter when it is not in use and the reasons for introducing an implanted CVC. Based on the results of the study it can be concluded that the second-year nursing students have insufficient knowledge of CVC. In order to correctly and safely handle a CVC, good theoretical knowledge and relevant practical experience are needed. The authors therefore believe that, in future, the classes should be organized in smaller groups with step-by-step demonstrations of individual procedures in handling a CVC, and the students encouraged to learn as actively as possible.
Decreased cardiopulmonary baroreflex sensitivity in Chagas' heart disease.
Consolim-Colombo, F M; Filho, J A; Lopes, H F; Sobrinho, C R; Otto, M E; Riccio, G M; Mady, C; Krieger, E M
2000-12-01
No study has been performed on reflexes originating from receptors in the heart that might be involved in the pathological lesions of Chagas' heart disease. Our study was undertaken to analyze the role of cardiopulmonary reflex on cardiovascular control in Chagas' disease. We studied 14 patients with Chagas' disease without heart failure and 12 healthy matched volunteers. Central venous pressure, arterial blood pressure, heart rate, forearm blood flow, and forearm vascular resistance were recorded during deactivation of cardiopulmonary receptors. By reducing central venous pressure by applying -10 and -15 mm Hg of negative pressure to the lower body, we observed (a) a similar decrease of central venous pressure in both groups; (b) a marked increase in forearm vascular resistance in the control group but a blunted increase in the Chagas' group; and (c) no significant changes in blood pressure and heart rate. To analyze cardiopulmonary and arterial receptors, we applied -40 mm Hg of lower-body negative pressure. As a consequence, (a) central venous pressure decreased similarly in both groups; (b) blood pressure was maintained in the control group, whereas in patients with Chagas' disease, a decrease in systolic and mean arterial pressure occurred; (c) heart rate increased in both groups; and (d) forearm vascular resistance increased significantly and similarly in both groups. Unloading of receptors with low levels of lower-body negative pressure did not increase forearm vascular resistance in patients with Chagas' disease, which suggests that the reflex mediated by cardiopulmonary receptors is impaired in patients with Chagas' disease without heart failure. Overall control of circulation appears to be compromised because patients did not maintain blood pressure under high levels of lower-body negative pressure.
Viana Taveira, Michelle Ribeiro; Lima, Luciana Santana; de Araújo, Cláudia Corrêa; de Mello, Maria Júlia Gonçalves
2017-02-01
Totally implantable venous access ports (TIVAPs) are used for prolonged central venous access, allowing the infusion of chemotherapy and other fluids and improving the quality of life of children with cancer. TIVAPs were developed to reduce the infection rates associated with central venous catheters; however, infectious events remain common and have not been fully investigated in pediatric oncology patients. A retrospective cohort was formed to investigate risk factors for central line-associated bloodstream infection (CLABSI) in pediatric cancer patients. Sociodemographic, clinical, and TIVAP insertion-related variables were evaluated, with the endpoint being the first CLABSI. A Kaplan-Meier analysis was performed to determine CLABSI-free catheter survival. Overall, 188 children were evaluated over 77,541 catheter days, with 94 being diagnosed with CLABSI (50%). Although coagulase-negative staphylococci were the pathogens most commonly isolated, Gram-negative microorganisms (46.8%) were also prevalent. In the multivariate analysis, factors that increased the risk for CLABSI were TIVAP insertion prior to chemotherapy (risk ratio [RR] = 1.56; P < 0.01), white blood cell count less than 1,000 mm -3 on the day of implantation (RR = 1.64; P < 0.01), and chronic malnutrition (RR = 1.41; P < 0.05). Median time without CLABSI following TIVAP insertion was 74.5 days. Risk factors for CLABSI in pediatric cancer patients with a TIVAP may be related to the severity of the child's condition at catheter insertion. Insertion of the catheter before chemotherapy and unfavorable conditions such as malnutrition and bone marrow aplasia can increase the risk of CLABSI. Protocols must be revised and surveillance increased over the first 10 weeks of treatment. © 2016 Wiley Periodicals, Inc.
Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek
2017-07-01
Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.
Catheter-Salvage in Home Infusion Patients with Central Line-Associated Bloodstream Infection
Caroff, Daniel A.; Norris, Anne H.; Keller, Sara; Vinnard, Christopher; Zeitler, Kristen E.; Lukaszewicz, Jennifer; Zborowski, Kristine A.; Linkin, Darren R.
2014-01-01
In a retrospective study of home infusion patients with central line-associated bloodstream infection, use of a central venous port, cancer diagnosis, and the absence of systemic inflammatory response syndrome were associated with use of catheter-salvage. Relapse of infection was uncommon. PMID:25465266
Beta-Blockers: An Abstracted Bibliography.
1989-04-04
on subjects in the supine position. Blood flow was measured by venous occlusion plethys- mography. Prugs were administered via indwelling catheter (one...PROCEDURES: Noninvasive measuremert of maximum oxygen intake, invasive measurement of systemic and pulmonary arterial pressures, arterial and mixed venous ...ratio was approximately 0.1:1. Central nervous system-related effects associated with propranolol and metoprolol appear to be the result of high brain
Benaya, A; Schwartz, Y; Kory, R; Yinnon, A M; Ben-Chetrit, E
2015-05-01
Peripheral venous access in elderly, hospitalized patients is often challenging. The usual alternative is insertion of a central venous catheter, with associated risk for complications. The purpose of this investigation was to determine the relative incidence of phlebitis secondary to lower as compared to upper extremity intravenous catheters (IVCs) and associated risk factors. A non-randomized, observational, cohort-controlled study was carried out. Consecutive patients receiving a lower extremity IVC were enrolled and compared with patients receiving an upper extremity IVC. Patients were followed from insertion until removal of the IVC. The major endpoint was phlebitis. The incidence of phlebitis secondary to upper extremity IVCs was 3/50 (6 %) compared to 5/53 (9.4 %) in lower extremity IVCs (χ(2) Yates = 0.08, p = 0.776). Age, gender, obesity, diabetes mellitus, site (arm versus leg, left versus right), and size of needle were not found to be risk factors for phlebitis according to univariate analysis. None of the patients developed bloodstream infection. In elderly patients with poor venous access, lower extremity IVCs are a reasonable and low-risk alternative to central venous catheters.
[Regional cerebral oxygen saturation as a marker of hemodynamic state following cardiac surgery].
García-Hernández, J A; Aldemira-Liz, A; Martínez-López, A I; Cayuela, A; Charlo-Molina, M T; Cano-Franco, J; Loscertales-Abril, M
2013-10-01
Regional cerebral oxygen saturation (rSO₂) is a measure of the general state of perfusion and oxygenation. We aim to analyze the relationship between this and various hemodynamic and respiratory parameters. Forty-three patients, operated on between October 2011 and July 2012, were included in this prospective observational descriptive study. The following parameters were measured: mean arterial pressure, both arterial and central venous oxygen saturation and partial pressures of oxygen and carbon dioxide, and lactate levels. From these parameters, the oxygenation index and the oxygen extraction ratio were calculated. These measurements were studied to evaluate whether rSO₂ correlated significantly with the other parameters. The average age and weight of the patients were 27.3 months and 9.2 kg, respectively. The rSO₂ correlated positively with both central venous oxygen saturation (r=0.73, P<.01) and mean arterial pressure (r=0.59, P<.01), and negatively with the oxygen extraction ratio (r=-0.7, P<.01). No correlation was found with the respiratory parameters. Concordance analysis established an acceptable Kappa index (> 0.4) between the rSO₂ and central venous oxygen saturation, and between the rSO₂ and oxygen extraction ratio. Regional cerebral oxygen saturation correlates well with hemodynamic parameters - mean arterial pressure, venous saturation, and the tissue oxygen extraction. However, it does not correlate with respiratory parameters. Copyright © 2012 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I
2005-07-01
The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).
Iatrogenic vertebral artery pseudoaneurysm due to central venous catheterization
Vasquez, Jay
2011-01-01
Central venous lines have become an integral part of patient care, but they are not without complications. Vertebral artery pseudoaneurysm formation is one of the rarer complications of central line placement. Presented is a rare case of two pseudoaneurysms of the vertebral and subclavian artery after an attempted internal jugular vein catheterization. These were successfully treated with open surgical repair and bypass. Open surgical repair remains the gold standard of treatment. Endovascular repair of vertebral artery pseudoaneurysms has been described with promising outcomes, but long-term results are lacking. Ultimately, the best treatment of these iatrogenic injuries should start with prevention. Well-documented techniques to minimize mechanical complications, including inadvertent arterial puncture, should be practiced and taught in training programs to avoid the potentially devastating consequences. PMID:21566753
Ultrasound-guided venous access for pacemakers and defibrillators.
Seto, Arnold H; Jolly, Aaron; Salcedo, Jonathan
2013-03-01
Ultrasound guidance is widely recommended to reduce the risk of complications during central venous catheter placement. However, ultrasound guidance is not commonly utilized for implanting leads for cardiac rhythm management devices. We describe our technique of ultrasound-guided pacemaker implantation, including a novel pull-through technique that allows percutaneous guidewire insertion prior to the first incision. We review the literature and recent advances in ultrasound imaging technology that may facilitate the adoption of ultrasound guidance. Ultrasound guidance provides a safe and rapid technique for extrathoracic subclavian or axillary venous lead placement. © 2012 Wiley Periodicals, Inc.
Pulhorn, H; Hartley, J C; Shanmuganathan, M; Lee, C H; Harkness, W; Thompson, D N P
2014-09-01
Increasingly, Onyx is used for endovascular embolization of aneurysms and arterio-venous malformations. Although reports in the literature on the use of Onyx are favourable, there have been so far no reports on the central nervous system (CNS) infection rate after embolisation with Onyx and no recommendations as to the management of these infections. We present two cases of paediatric patients who acquired CNS infection with Pseudomonas aeruginosa after Onyx embolisation of AVMs and describe their subsequent management. Presence of established infection after Onyx embolisation should be dealt with by removal of infected material, administration of appropriate antibiotic therapy and supportive treatment.
Moraxella osloensis: an unusual cause of central venous catheter infection in a cancer patient
Hadano, Yoshiro; Ito, Kenta; Suzuki, Jun; Kawamura, Ichiro; Kurai, Hanako; Ohkusu, Kiyofumi
2012-01-01
Moraxella osloensis is a rare causative organism of infections in humans, with most cases reported in cancer patients. We report the case of a 67-year-old Japanese man with advanced cancer of the pancreatic head and multiple liver metastases who developed fever with chills. Blood culture was found to be positive for Gram-negative bacilli that were aerobic, oxidase-positive, and catalase-positive. M. osloensis was identified by 16 rRNA gene sequencing. Prompt control of the infection was achieved by treatment with cefepime for 14 days, without the need for removal of the central venous catheter. PMID:23109812
Moraxella osloensis: an unusual cause of central venous catheter infection in a cancer patient.
Hadano, Yoshiro; Ito, Kenta; Suzuki, Jun; Kawamura, Ichiro; Kurai, Hanako; Ohkusu, Kiyofumi
2012-01-01
Moraxella osloensis is a rare causative organism of infections in humans, with most cases reported in cancer patients. We report the case of a 67-year-old Japanese man with advanced cancer of the pancreatic head and multiple liver metastases who developed fever with chills. Blood culture was found to be positive for Gram-negative bacilli that were aerobic, oxidase-positive, and catalase-positive. M. osloensis was identified by 16 rRNA gene sequencing. Prompt control of the infection was achieved by treatment with cefepime for 14 days, without the need for removal of the central venous catheter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jahnke, Thomas, E-mail: thomas.jahnke@gmx.net; Schaefer, Phillip Jost; Heller, Martin
2008-07-15
We report a case of massive hemothorax due to inadvertent puncture of an aberrant right subclavian artery during central venous access. Iatrogenic laceration at the origin of the right internal thoracic artery was successfully treated with coil embolization of the internal thoracic artery followed by stent-graft placement into the subclavian artery. Due to its elongated and abnormal course, an aberrant right subclavian artery may predispose to inadvertent puncture during vein catheterization and should be recognized as a potential threat for such procedures. Our case emphasizes that ultrasound guidance should be used routinely for central venous lines wherever possible.
Guimaraes, M; Uflacker, R; Schonholz, C; Hannegan, C; Selby, B
2008-06-01
Although rare, misplacement of central venous catheters in supra-aortic arteries is potentially fatal. Five patients had safe catheters removal using percutaneous closure devices. Three patients were coagulopathic, 3 under intensive care and 1 in immediate postoperative limb amputation. Patients were treated successfully, with immediate hemostasis and without complications in a mean follow-up of 12.5 months. Although the number of patients is small, the closure devices proved to be safe. This is a minimally invasive alternative technique in the management of large bore catheters removed from non-compressible puncture sites such as subclavian and brachiocephalic arteries.
Ribeiro, A F; Neto, I S; Maia, I; Dias, C
2018-04-19
Central venous catheters are widely used in critically ill patients; however, they are also associated with increased morbidity and mortality. The literature may underestimate the incidence of catheter-inducible right atrial thrombi that are asymptomatic but potentially life threatening. The recognized risk factors for its development include infections related to the catheter, endothelial injury secondary to mechanical and chemical damage induced by certain medications and infused fluids. The characteristics of the patient and the catheter, such as size, material, type, location and ease of insertion, as well as the duration of placement play an additional role. We report the case of a 38-year-old man, who developed an asymptomatic catheter-inducible right atrial thrombi requiring open heart surgery, after taking a central venous catheter for thirty-five days. The present case highlights existing limitations in making a correct and fast diagnosis, which should be anticipated in patients with multiple risk factors for thrombosis. Given the limited recommendations available, we consider that the most appropriate strategy should be individualized. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.
Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. Amore » combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant (p = 0.6). Aspiration occlusion occurred in 13 patients (11.7%). Intracatheter urokinase was infused in eight of these patients and successfully restored catheter function in all but two instances. These complication rates are comparable to or better than those reported with chest ports.Conclusion: Peripheral ports for long-term central venous access placed by interventional radiologists in the interventional radiology suite are as safe and as effective as chest ports.« less
Solinas, Gianfranca; Platini, Francesca; Trivellato, Maurizio; Rigo, Carla; Alabiso, Oscar; Galetto, Alessandra S
2017-07-14
Patients with cancer need stable venous access using central vascular devices like central venous ports and peripherally inserted central catheters that can be used for a wide range of indications. Numerous flushing protocols exist including different frequencies for catheter locking to maintain catheter patency. The aim of this retrospective study was to evaluate the incidence of lumen occlusion of central venous ports in a group of adult cancer patients, adopting a policy of locking with normal saline every three months. This is a single-center retrospective observational study. During follow-up, we analyzed adult cancer patients who had undergone port insertion from January 1st, 2007 to August 31st, 2014. Flushing and locking were performed every three months with a syringe containing normal saline. We collected data from 381 patients with ports inserted in subclavian vein (379 patients) and in the right jugular vein (2 patients). Locking was performed during 3-monthly follow-up visits. Median follow-up was 810 days (90-2700 days). Among 381 ports, 59 were removed; the reasons for removal were: end of use (45 cases), catheter rupture (9 cases), dislocation (3 cases) and catheter-related bloodstream infection (2 cases). We had no reports of lumen occlusion. Our data suggest that locking ports with normal saline every three months is not associated with an increased risk of lumen occlusion.
Loubani, Osama M; Green, Robert S
2015-06-01
The aim of this study was to collect and describe all published reports of local tissue injury or extravasation from vasopressor administration via either peripheral intravenous (IV) or central venous catheter. A systematic search of Medline, Embase, and Cochrane databases was performed from inception through January 2014 for reports of adults who received vasopressor intravenously via peripheral IV or central venous catheter for a therapeutic purpose. We included primary studies or case reports of vasopressor administration that resulted in local tissue injury or extravasation of vasopressor solution. Eighty-five articles with 270 patients met all inclusion criteria. A total of 325 separate local tissue injury and extravasation events were identified, with 318 events resulting from peripheral vasopressor administration and 7 events resulting from central administration. There were 204 local tissue injury events from peripheral administration of vasopressors, with an average duration of infusion of 55.9 hours (±68.1), median time of 24 hours, and range of 0.08 to 528 hours. In most of these events (174/204, 85.3%), the infusion site was located distal to the antecubital or popliteal fossae. Published data on tissue injury or extravasation from vasopressor administration via peripheral IVs are derived mainly from case reports. Further study is warranted to clarify the safety of vasopressor administration via peripheral IVs. Copyright © 2015 Elsevier Inc. All rights reserved.
Wisén, E; Svennerholm, K; Bown, L S; Houltz, E; Rizell, M; Lundin, S; Ricksten, S-E
2018-03-26
Various methods are used to reduce venous blood pressure in the hepato-splanchnic circulation, and hence minimise blood loss during liver surgery. Previous studies show that combination of vasopressin and nitroglycerin reduces portal pressure and flow in patients with portal hypertension, and in this study we investigated this combination in patients with normal portal pressure. In all, 13 patients were studied. Measurements were made twice to confirm baseline (C1 and BL), during vasopressin infusion 4.8 U/h (V), and during vasopressin infusion combined with nitroglycerin infusion (V + N). Portal venous pressure (PVP), hepatic venous pressure (HVP), central haemodynamics and arterial and venous blood gases were obtained at each measuring point, and portal (splanchnic) and hepato-splanchnic blood flow changes were calculated. Vasopressin alone did not affect PVP, whereas HVP increased slightly. In combination with nitroglycerin, PVP decreased from 10.1 ± 1.6 to 8.9 ± 1.3 mmHg (P < 0.0001), and HVP decreased from 7.9 ± 1.9 to 6.2 ± 1.3 mmHg (P = 0.001). Vasopressin reduced portal blood flow by 47 ± 19% and hepatic venous flow by 11 ± 18%, respectively. Addition of nitroglycerin further reduced portal- and hepatic flow by 55 ± 13% and 30 ± 13%, respectively. Vasopressin alone had minor effects on central haemodynamics, whereas addition of nitroglycerin reduced cardiac index (3.2 ± 0.7 to 2.7 ± 0.5; P < 0.0001). The arterial-portal vein lactate gradient was unaffected. The combination of vasopressin and nitroglycerin decreases portal pressure and hepato-splanchnic blood flow, and could be a potential treatment to reduce bleeding in liver resection surgery. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walser, Eric M., E-mail: walser.eric@mayo.edu
The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist ofmore » catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.« less
Menegueti, Mayra Gonçalves; Betoni, Natália Cristina; Bellissimo-Rodrigues, Fernando; Romão, Elen Almeida
2017-01-01
Bloodstream infections are the second most common cause of death among patients on hemodialysis. This study aimed to evaluate the incidence of and risk factors associated with central venous catheter-related infections in patients undergoing hemodialysis, and to identify and characterize the type and antimicrobial susceptibility profiles of the primary microorganisms isolated during one year of follow-up. A prospective cohort study was conducted in 2014 in a hemodialysis referral center. We included 200 outpatients with acute kidney injury who had no permanent venous access. A nurse assessed the patients for signs of infection three times per week during dressing changes. The clinicopathologic characteristics of patients with and without local or systemic infection were compared. Fifty-five episodes of catheter-related infections occurred in 43 (22%) patients; 38 (69%) were bloodstream infections and 17 (31%) were local infections. Thirty-two (75%) patients with infection had femoral vein catheter placement. In total, 6,240 hemodialysis sessions were performed; the rates of primary bloodstream and local infection were 6.1 and 2.7 episodes per 1,000 patients on daily dialysis, respectively. In the univariate analysis, diabetes was significantly associated with the development of infection, while level of education, ethnicity, age, and sex were not. Gram-negative bacteria were primarily isolated from blood culture specimens (55% of samples). Of the Gram-negative isolates, 56% were resistant to the carbapenems. We identified a high incidence of catheter-related infections caused by resistant microorganisms in patients undergoing hemodialysis via central venous catheters.
Rosenberg, Rebecca E; Devins, Lea; Geraghty, Gail; Bock, Steven; Dugan, Christina A; Transou, Marjorie; Phillips, Michael; Lighter-Fisher, Jennifer
2015-10-01
Central venous catheters are crucial devices in the care of hospitalized children, both in and out of critical care units, but the concomitant risk of central line-associated bloodstream infection (CLABSI) affects 15,000 Americans annually. In 2012, CLABSI rates varied among units from 6.8/1,000 to 1.0/1,000 in a 109-bed children's service within NYU Langone Medical Center (NYULMC; New York City), a 1,069-bed tertiary care academic medical center. In response to variation in central line-related practices and infection prevention rates, a CLABSI Prevention Core Team began an effort to standardize central venous catheter (CVC) care across all pediatric units (ICU and non-ICU). Momentum in this quality improvement (QI) work was interrupted when Superstorm Sandy shuttered the flagship hospital, but the relatively decreased clinical load provided a "downtime" opportunity to address CLABSI prevention. The first phase of the collaborative effort, Booster 1, Planning/Initial Phase: Development of a Pediatric Central Venous Catheter Working Group, was followed by Booster 2, Maintenance/Sustaining Phase: Transitioning for Sustainability and Adopting Model for Improvement. Data in the subsequent 21 months after the temporary closure of the facility (January 2013-September 2014) showed an increase in maintenance bundle reliability. The inpatient CLABSI rate for patients<18 years decreased from an annual rate of 2.7/1,000 line days (2012) to 0.6/1,000 line days (2013) to 0.5/1,000 line days as of August 2014. There was a decrease in pediatric CLABSI events and no significant change in line days. Key elements contributing to initial success with evolving QI capacity and resources were likely multi-factorial, including staff and leadership engagement, culture change, consistent guidelines, and accountability by individuals and by our multidisciplinary core team.
Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying
2015-01-01
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758
Obesity, sedentary lifestyle, and video games: The new thrombophilia cocktail in adolescents.
Kohorst, Mira A; Warad, Deepti M; Nageswara Rao, Amulya A; Rodriguez, Vilmarie
2018-07-01
Rates of venous thromboembolism have increased in the adolescent population over the last two decades, likely due to advanced diagnostics, increased use of central venous catheters, chronic medical conditions, obesity, and oral contraceptive use. Of these factors, a modifiable risk factor for adolescents is obesity. Sedentary lifestyle and prolonged immobilization are additional prothrombotic risk factors that are often associated with obesity. With ever-increasing screen time, sedentary behavior has risen accordingly, especially among gamers. We present four cases of adolescents who developed life-threatening venous thromboembolic events in the setting of obesity, sedentary lifestyle and/or immobilization, and prolonged video game use. © 2018 Wiley Periodicals, Inc.
Journal of Special Operations Medicine. Volume 9, Edition 2, Spring 2009
2009-01-01
patient. The most accessible veins for intra- venous catheterization include the cephalic vein on the thoracic limb (Figure 10), the saphenous vein on...threatening hypotension by restoring central blood vol- ume through enhancement of venous blood flow back to the heart with each inspiratory effort. HOW...examination of the latest advancements in medicine and the history of unconventional warfare medicine. Content: Content of this publication is not
Ahlin, Catharina; Klang-Söderkvist, Birgitta; Brundin, Seija; Hellström, Birgitta; Pettersson, Karin; Johansson, Eva
2006-01-01
The objectives of this study were to evaluate registered nurses' (RN) compliance with a local clinical central venous access device (CVAD) protocol after completing an educational program and to determine RNs' perception of the program. Seventy-five RNs working in hematology participated in the educational part of the program. Sixty-eight RNs were examined while changing CVAD dressings or placing a Huber needle into a port on actual patients. Sixty percent of the RNs passed the examination and reported that the program increased their knowledge. The results indicated that the educational program could be recommended for use when implementing a new clinical protocol.
Occult central venous stenosis leading to airway obstruction after subtotal parathyroidectomy.
Meiklejohn, Duncan A; Chan, Dylan K; Lalakea, M Lauren
2016-07-01
Subtotal parathyroidectomy may be indicated in patients with chronic renal failure and tertiary hyperparathyroidism, a population at increased risk for central venous stenosis (CVS) due to repeated vascular access. Here we report a case of complete upper airway obstruction precipitated by subtotal parathyroidectomy with ligation of anterior jugular vein collaterals in a patient with occult CVS. This case demonstrates a previously unreported risk of anterior neck surgery in patients with chronic renal failure. We present a review of the literature and discuss elements of the history and physical examination suggestive of occult CVS, with additional workup proposed for appropriate cases. Recommendations are discussed for perioperative and postoperative care in patients at increased risk for CVS.
Neonatal venous cerebral hemorrhage. Report of two cases.
Misra, Sanjay N; Misra, Ashish K
2003-10-15
Intracranial pathological changes can occur as a result of impaired craniocervical venous return. Thrombosis of central venous access catheters was demonstrated in two neonates born at 38 and 27 weeks' gestation. Neither infant developed hemorrhage of prematurity as confirmed on cranial ultrasonography. Clinical evidence of vena cava thrombosis and associated spontaneous intraventricular hemorrhage developed on Day 24 and 36, respectively, and these findings were confirmed on imaging studies. In one infant the hemorrhage was accompanied by communicating hydrocephalus. The cause of the intracranial disease was attributable to the retrograde cerebral venous congestion. This, together with the primitive venous bed developing in the periventricular region, was associated with the spontaneous hemorrhage in the region of the foramen of Monro. To the authors' knowledge, this is the first report in the English-language literature of spontaneous neonatal intracerebral hemorrhage, due to thrombosis of the superior or inferior vena cava. The natural history of this condition is resolution without sequelae after appropriate therapeutic intervention for the vena cava thrombosis.
Infusion of noradrenaline through the proximal line of a migrated central venous catheter.
Freer, M; Noble, S
2012-08-01
A 41-year-old, obese, patient was admitted to Accident and Emergency with a history of leg cellulitis. A central line was inserted. Documented aspiration of blood from all lines, central venous pressure trace obtained and correct position noted on the chest X-ray (CXR). The patient became increasingly septic despite antibiotic therapy. He was subsequently commenced on a noradrenaline infusion; however, the blood pressure was unresponsive. On admission to the intensive care unit (ICU), it was noted he had an area of white skin over the right clavicle. The infusions were stopped and a CXR confirmed proximal migration of the line. The central line was re-sited and his noradrenaline recommenced with an improvement in his blood pressure. Acute renal failure developed which required haemofiltration for 24 hours. The condition improved and the patient was discharged from ICU. It took several weeks for his renal function to return to normal, but he was discharged home with no permanent damage.
Risk factors for venous port migration in a single institute in Taiwan.
Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen
2014-01-14
An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor.
Rao, Neal M; Raychev, Radoslav; Kim, Doojin; Liebeskind, David S
2012-11-01
Posterior reversible encephalopathy syndrome (PRES) is a condition characterized by reversible symptoms including headache, visual disturbances, focal neurological deficits, altered mentation, and seizures. It has been associated with circumstances that may affect the cerebrovascular system, such as hypertension, eclampsia, and immunosuppression with calcineurin inhibitors. The underlying etiology of PRES has remained unclear; however, cerebrovascular autoregulatory dysfunction, hyperperfusion, and endothelial activation have been implicated. We describe a case of a young patient with lung transplant, who presented with headache, acute binocular blindness, and seizure immediately after infusion of saline through a peripherally inserted central catheter line, which inadvertently terminated cephalad in the left internal jugular vein, near the jugular foramen. Subsequent brain magnetic resonance imaging revealed vasogenic edematous lesions in a pattern consistent with PRES--a diagnosis supported by his constellation of symptoms, history of lung transplantation on tacrolimus immunosuppression, and relative hypertension. This is the first reported case describing the development of PRES after the insertion of a peripherally inserted central catheter line. The development of PRES in a typical high-risk patient immediately after cerebral venous outflow obstruction implicates the role of the cerebral venous system and provides potential insight into the mechanism of this disorder that remains of unclear pathogenesis.
Fagnani, D; Franchi, R; Porta, C; Pugliese, P; Borgonovo, K; Bertolini, A; Duro, M; Ardizzoia, A; Filipazzi, V; Isa, L; Vergani, C; Milani, M; Cimminiello, C
2007-03-01
Recent guidelines do not recommend antithrombotic prophylaxis (AP) to prevent catheter-related thrombosis in cancer patients with a central line. This study assessed the management of central lines in cancer patients, current attitude towards AP, catheter-related and systemic venous thromboses, and survival. Of 1410 patients enrolled, 1390 were seen at least once in the 6-month median follow-up. Continuous AP, mainly low-dose warfarin, was given to 451 (32.4%); they were older, with a more frequent history of venous thromboembolism (VTE), and more advanced cancer. There was no difference in catheter-related thrombosis in patients given AP or not (2.8% and 2.2%, odds ratio 1.29, 95% confidence interval 0.64-2.6). The median time to first catheter-related complication was 120 days. Systemic VTE including deep and superficial thromboses and pulmonary embolism, were less frequent with AP (4% versus 8.2%, P = 0.005). Mortality was also lower (25% versus 44%, P = 0.0001). Multiple logistic regression analysis found only advanced cancer and no AP significantly associated with mortality. No major bleeding was recorded with AP. Current AP schedules do not appear to prevent catheter-related thrombosis. Systemic VTE and mortality, however, appeared lower after prophylaxis.
Tazzioli, Giovanni; Gargaglia, Eleonora; Vecchioni, Ilaria; Papi, Simona; Di Blasio, Petronilla; Rossi, Rosario
2015-01-01
Central venous catheters are often required in oncologic patients for long-term safe administration of chemotherapeutic agents, antibiotics, and parenteral nutrition. Rupture of these devices and intracardiac migration is a rare complication. We report one spontaneous rupture and embolization of a totally implantable vascular access device (TIVAD) in an asymptomatic patient. A 50-year-old woman received a TIVAD silicone catheter 8 FR for adjuvant chemotherapy. After 3 years of port time in situ, during a follow-up control, a catheter malfunction was found and radiologic investigations showed a rupture and migration of the catheter to the right ventricle. The attempt to remove the fragment under fluoroscopic control using the femoral route was unsuccessful. We did not try a surgical approach because of the complete absence of symptomatology and hemodynamic impairment. The catheter rupture and intracardiac embolization is a rare complication associated with totally implantable or tunneled central venous catheters. When such an event happens, the patient should be managed by expert hemodynamists or interventional radiologists making an effort to remove the fragment without surgical measures. When the intravascular percutaneous route fails, the possibility to leave the fragmented catheter in heart chambers should be evaluated, being surgery questionable in asymptomatic patients.
The role of interventional radiology in management of benign and malignant gynecologic diseases.
Yu, Hyeon; Stavas, Joseph M
2013-10-01
This article focuses on the role of interventional radiology in the therapeutic and diagnostic management of benign and malignant gynecologic conditions. The subspecialty of interventional radiology utilizes minimally invasive advanced image-guided percutaneous techniques in gynecology that include central venous catheter placement, fluid aspiration, drainage catheter placement, tissue biopsy, inferior vena cava filter placement, and pelvic arterial embolization. Central venous catheters, such as ports, peripherally inserted central catheters, and tunneled catheters, are placed for intermediate to long-term intravenous chemotherapy or total parental nutrition or antibiotics. Patients with refractory malignant ascites or pleural effusion from seeding of advanced gynecologic cancers may benefit by percutaneous aspiration of fluid collections or placement of drainage catheters. Postoperative fluid collections including abscess, seroma, or lymphocele are managed by percutaneous drainage catheter insertion. Pelvic, peritoneal, or retroperitoneal masses can be sampled by image-guided percutaneous biopsy or aspiration of fluid to determine a pathologic diagnosis. Certain patients are at risk for deep venous thrombosis with pulmonary embolism and may benefit from an inferior vena cava filter. Patients with uncontrolled postoperative or postpartum bleeding can be effectively managed with emergent transarterial pelvic embolization. Each of the aforementioned interventions with indications, expected benefits, and complications is described including a published literature.
Upper Body Venous Compliance Exceeds Lower Body Venous Compliance in Humans
NASA Technical Reports Server (NTRS)
Watenpaugh, Donald E.
1996-01-01
Human venous compliance hypothetically decreases from upper to lower body as a mechanism for maintenance of the hydrostatic indifference level 'headward' in the body, near the heart. This maintains cardiac filling pressure, and thus cardiac output and cerebral perfusion, during orthostasis. This project entailed four steps. First, acute whole-body tilting was employed to alter human calf and neck venous volumes. Subjects were tilted on a tilt table equipped with a footplate as follows: 90 deg, 53 deg, 30 deg, 12 deg, O deg, -6 deg, -12 deg, -6 deg, O deg, 12 deg, 30 deg, 53 deg, and 90 deg. Tilt angles were held for 30 sec each, with 10 sec transitions between angles. Neck volume increased and calf volume decreased during head-down tilting, and the opposite occurred during head-up tilt. Second, I sought to cross-validate Katkov and Chestukhin's (1980) measurements of human leg and neck venous pressures during whole-body tilting, so that those data could be used with volume data from the present study to calculate calf and neck venous compliance (compliance = (Delta)volume/(Delta)pressure). Direct measurements of venous pressures during postural chances and whole-body tilting confirmed that the local changes in venous pressures seen by Katkov and Chestukhin (1980) are valid. The present data also confirmed that gravitational changes in calf venous pressure substantially exceed those changes in upper body venous pressure. Third, the volume and pressure data above were used to find that human neck venous compliance exceeds calf venous compliance by a factor of 6, thereby upholding the primary hypothesis. Also, calf and neck venous compliance correlated significantly with each other (r(exp 2) = 0.56). Fourth, I wished to determine whether human calf muscle activation during head-up tilt reduces calf venous compliance. Findings from tilting and from supine assessments of relaxed calf venous compliance were similar, indicating that tilt-induced muscle activation is relatively unimportant. Low calf venous compliance probably results from stiffer venous, skeletal muscle, and connective tissues, and better-developed local and central neural controls of venous distensibility. This research establishes that upper-to-lower body reduction of venous compliance can explain headward positioning of the hydrostatic indifference level in humans.
Ito, Hiroki; Murata, Masaya; Ide, Yujiro; Sugano, Mikio; Kanno, Kazuyoshi; Imai, Kenta; Ishido, Motonori; Fukuba, Ryohei; Sakamoto, Kisaburo
2016-01-01
OBJECTIVES Fontan candidates with mixed totally anomalous pulmonary venous connection often have postoperative pulmonary venous obstruction after cavopulmonary anastomosis. Because some pulmonary venous obstructions have no intimal hypertrophy at reoperation, we considered such pulmonary venous obstructions to be caused by 3D deformities arising from dissection or mobilization of the vessels, and hypothesized that keeping the pulmonary venous branches in a natural position could avoid such obstruction. Here, we evaluated a modified hemi-Fontan strategy consisting of minimal dissection with no division of vessels and patch separation between systemic and pulmonary venous flow. METHODS We retrospectively reviewed clinical records of infants with a functional single ventricle and supracardiac anomalous pulmonary venous connection who had undergone this procedure between 2002 and 2012. RESULTS Nine infants underwent this procedure (median age, 5.6 months; range 3.2–30), all with right atrial isomerism and several pulmonary venous branches directly and separately connecting to the superior vena cava. In 5 patients, all pulmonary veins drained into the superior vena cava; in 1, the right pulmonary veins drained into the superior vena cava and in 3, a pulmonary venous branch drained into the superior vena cava. The median follow-up was 6.9 years (0.8–13 years). Three patients underwent reoperation for postoperative pulmonary venous obstruction caused by intimal hypertrophy; however, we confirmed no pulmonary venous obstruction caused by 3D deformities on the pulmonary venous branches connecting separately to the superior vena cava. Although 2 patients were effectively relieved from pulmonary venous obstruction, 1 died due to recurrent pulmonary venous obstruction. There was no late death and no sinus-node dysfunction. Eight patients underwent successful Fontan operation and catheterization. The median interval from the Fontan operation to the latest catheterization was 3.7 years (0.9–3.7 years). The median arterial oxygen saturation was 94% (91–97%) and the central venous pressure was 12 mmHg (8–14 mmHg); no deficiency of pulmonary arteries and veins was noted. CONCLUSIONS For patients with functional single ventricle and anomalous pulmonary venous connections to the superior vena cava, our novel strategy of second-stage palliation could avoid postoperative pulmonary venous obstruction caused by 3D deformities, but may not eliminate pulmonary venous obstruction caused by intimal hypertrophy. PMID:26860898
Central venous catheter integrity during mechanical power injection of iodinated contrast medium.
Macha, Douglas B; Nelson, Rendon C; Howle, Laurens E; Hollingsworth, John W; Schindera, Sebastian T
2009-12-01
To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.
Heppner, Hans Juergen; Singler, Katrin; Kwetkat, Anja; Popp, Steffen; Esslinger, Adelheid Susanne; Bahrmann, Philipp; Kaiser, Matthias; Bertsch, Thomas; Sieber, Cornel Christian; Christ, Michael
2012-10-01
Guidelines for the management of sepsis have been published but not validated for elderly patients, though a prompt work-up and initiation of appropriate therapy are crucial. This study assesses the impact of a sepsis protocol on timelines for therapy and mortality in standardized management. Consecutive patients aged 70 years and older who were diagnosed with sepsis and admitted during the observation periods were included in this before-and-after study at a medical intensive care unit (ICU). Age, sex, and process-of-care variables including timely administration of antibiotics, obtaining blood cultures before the start of antibiotics, documenting central venous pressure, evaluation of central venous blood oxygen saturation, fluid resuscitation, and patient outcome were recorded. A total of 122 patients were included. Sepsis was diagnosed in 22.9 % of patients prior to the introduction of the protocol and 57.4 % after introduction. Volume therapy was conducted in 63.9 % of the patients (11.5 % preprotocol). Blood culture samples were taken prior to the administration of antibiotics in 67.2 % of patients (4.9 % preprotocol), and antibiotics were applied early in 72.1 % of patients (32.8 % preprotocol). Lactate was set in 77.0 % of patients (11.5 % preprotocol). A central venous catheter was inserted in 88.5 % of patients (68.9 % preprotocol), and the target central venous pressure was achieved in 64.3 % of patients (47.2 % preprotocol). ICU mortality was reduced by 5.2 % and hospital mortality by 6.4 %. The use of standardized order sets for the management of sepsis in elderly patients should be strongly recommended for better performance in treatment. Compliance with the protocol was associated with reduced length of stay, reduced mortality, and improved initial appropriate therapy.
Fang, Shirong; Yang, Jinhong; Song, Lei; Jiang, Yan; Liu, Yuxiu
2017-01-01
Background Central venous catheters (CVCs) have been an effective access for chemotherapy instead of peripherally intravenous catheters. There were limited studies on the choices and effects of different types of CVCs for chemotherapy. The aim of this study was to compare the complications, cost, and patients’ quality of life and satisfaction of three commonly used CVCs for chemotherapy, such as implanted venous port, peripherally inserted central catheters (PICCs), and external non-tunneled central venous catheters (NTCs). Methods A double-center prospective cohort study was carried out from March 2014 to December 2016. Catheterization situation, complications, catheter maintenance, cost, and patients’ quality of life and satisfaction were recorded, investigated, and analyzed. Forty-five ports, 60 PICCs and 40 NTCs were included. All the CVCs were followed up to catheter removal. Results There was no statistical difference in catheterization success rates between port and PICC. NTC had less success rate by one puncture compared with port. Ports had fewer complications compared with PICCs and NTCs. The complication rates of ports, PICCs and NTCs were 2.2%, 40%, and 27.5%, respectively. If the chemotherapy process was <12 months, NTCs cost least, and the cost of port was much higher than PICC and NTC. When the duration time was longer than 12 months, the cost of port had no difference with the cost of PICC. Quality of life and patients’ satisfaction of port group were significantly higher than the other two groups. Conclusion Although port catheterization costs more and needs professional medical staff and strict operational conditions, ports have fewer complications and higher quality of life and patients’ satisfaction than PICCs and NTCs. Therefore, not following consideration of the economic factor, we recommend port as a safe and an effective chemotherapy access for cancer patients, especially for whom needing long chemotherapy process. PMID:28744109
It all unraveled from there: case report of a central venous catheter guidewire unraveling.
Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc
2014-12-01
Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.
Villalobos, Juan M; Castro, José A; Avilés, Alvaro; Peláez, M Claudia; Somogyi, Teresita; Sandoval, Lilliana
2016-04-01
Invasive Candida bloodstream infections are frequent and display high mortality in clinical practice. There is scarce published on this topic in Central America. To characterize the epidemiology of candidemia in a hospital setting in Costa Rica. 210 cases of nosocomial candidemia were analyzed in patients over 17 years of age, admitted to Hospital Mexico, between 2007 and 2011. Descriptive and temporary analyses were performed and the risk factors associated with C. parapsilosis and survival were evaluated. The incidence rate of candidemia was 1.47 cases per 1,000 admissions. The non-albicans Candida represented 62% of the isolated yeasts. Except for 2009, C. parapsilosis was the most commonly isolated species in four out of the five years reviewed, followed by C. albicans. There was a strong association between C. parapsilosis, the presence of a central venous catheter (OR: 4.8, CI 95%: 1.8-14.6, p < 0.001) and the use of parenteral nutrition (p: 0.008). The 30-day mortality was 50%. Candida albicans displayed the highest mortality and C. parapsilosis the lowest. Patients who did not receive anti-fungal treatment showed a significantly higher probability of death. The high incidence of candidemia from C. parapsilosis is directly related to the use of central venous catheters and parenteral nutrition. There is a need for creating local guidelines addressing the use of central venous catheters and parenteral nutrition, as well as implementing hand hygiene protocols.
Annual Progress Report Fiscal Year 1990
1991-03-25
87/25 (C) Axillary Venous Sickling in Individuals with Sickle Cell Trait During Upper Extremity Exercise in a Ilypoxic Environment (Monitor: Dr. Ortiz...I ’d Dire, Daniel J.: K8/77 (0) Use of Venous pH in the Initial Evaluation of Pediatric Patients with Diabetic Kcioacidosis...top oercjilu this potential pitfall. At the time of peak. antibody synthesis, rabbits will be bled sia the marginal ear %vim-o central artery in the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Robert M.; David, Elizabeth; Pugash, Robyn A.
Fibrotic central venous occlusions in patients with thoracic malignancy and prior radiotherapy can be impassable with standard catheters and wires, including the trailing or stiff end of a hydrophilic wire. We report two patients with superior vena cava syndrome in whom we successfully utilized a radiofrequency guide wire (PowerWire, Baylis Medical, Montreal, Quebec, Canada) to perforate through the occlusion and recanalize the occluded segment to alleviate symptoms.
Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J
2010-01-01
To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (p<0.001). Perfusion of amiodarone [adjusted OR (AOR) 25.97; 95% CI=7.29-92.55, p=0.0001] and cefotaxime (AOR 2.90; 95% CI=1.29-6.52, p=0.01) and the shift when the catheters were placed (AOR for morning vs. night shift 0.60; 95% CI=0.35-1.02, p=0.063) were independently associated to the development of PPIVC. A history of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.
[Complications associated to central venous catheters in hematology patients].
García-Gabás, Carmen; Castillo-Ayala, Ana; Hinojo-Marín, Begoña; Muriel-Abajo, M Ángeles; Gómez-Gutiérrez, Isabel; de Mena-Arenas, Ana M; Rodríguez-Gonzalo, Ana; Chao-Lozano, Cristina; García-Menéndez, Carmen; Madroñero-Agreda, M Antonia
2015-01-01
To discover the incidence of central venous catheters (tunnelled, subcutaneous and PICC) in patients with onco-hematological conditions, hospitalized in the Hematology or Transplantations of Hematopoietic Stem Cells Units, in two tertiary care hospitals. A cross-sectional, descriptive study form was developed in order to gather sociodemographic, clinical data as well as complications and follow-up of the care protocol. Each catheter was assigned a correlative identification number. Information was collected on 366 catheters: 185 in the University Hospital Ramón y Cajal (HURYC), 80 tunnelled, 40 subcutaneous venous access and 65 PICC, and 181 in the University Hospital Gregorio Marañón (HUGM), 101 tunnelled and 80 subcutaneous venous access. Major complications in the tunnellized were infections (13.7% in HURYC vs. 6.8% in HUGM - p<0.001) and occlusions (at least once in 3.8% vs. 21.8%). In subcutaneous venous access, infections were confirmed in 5% in HURYC vs. 1.2% in HUGM. There were occlusions at least once in 10% in HUGM and no other significant complications were detected. Regarding PICC, information was only collected in HURYC, where complications were phlebitis 10.8%, thrombosis 7.7%, confirmed or suspected infection 4.6%, occlusion at least once 7.7%. Differences between hospitals with regard to major complications, infection and occlusion may be related to different care protocol. We need to stress the high incidence of phlebitis and thrombosis in PICC catheters, compared with data of lower incidence of other papers. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Advanced imaging in acute and chronic deep vein thrombosis
Karande, Gita Yashwantrao; Sanchez, Yadiel; Baliyan, Vinit; Mishra, Vishala; Ganguli, Suvranu; Prabhakar, Anand M.
2016-01-01
Deep venous thrombosis (DVT) affecting the extremities is a common clinical problem. Prompt imaging aids in rapid diagnosis and adequate treatment. While ultrasound (US) remains the workhorse of detection of extremity venous thrombosis, CT and MRI are commonly used as the problem-solving tools either to visualize the thrombosis in central veins like superior or inferior vena cava (IVC) or to test for the presence of complications like pulmonary embolism (PE). The cross-sectional modalities also offer improved visualization of venous collaterals. The purpose of this article is to review the established modalities used for characterization and diagnosis of DVT, and further explore promising innovations and recent advances in this field. PMID:28123971
Pua, Uei
2014-10-01
Central venous perforation during dialysis catheter insertion is a potentially fatal complication. Prompt recognition and judicious initial steps are important in optimizing the outcome. The purpose of this manuscript is to illustrate the imaging features and steps in initial management. © 2014 International Society for Hemodialysis.
Complication Rates of 3% Hypertonic Saline Infusion Through Peripheral Intravenous Access.
Perez, Claudia Andira; Figueroa, Stephen A
2017-06-01
Hyperosmolar therapy with hypertonic saline (HTS) is a cornerstone in the management of intracranial hypertension and hyponatremia in the neurological intensive care unit. Theoretical safety concerns remain for infiltration, thrombophlebitis, tissue ischemia, and venous thrombosis associated with continuous 3% HTS administered via peripheral intravenous (pIV) catheters. It is common practice at many institutions to allow only central venous catheter infusion of 3% HTS. Hospital policy was changed to allow the administration of 3% HTS via 16- to 20-gauge pIVs to a maximum infusion rate of 50 mL/h in patients without central venous access. We prospectively monitored patients who received peripheral 3% HTS as part of a quality improvement project. We documented gauge, location, maximum infusion rate, and total hours of administration. Patients were assessed for infiltration, erythema, swelling, phlebitis, thrombosis, and line infection. There were 28 subjects across 34 peripheral lines monitored. Overall, subjects received 3% HTS for a duration between 1 and 124 hours with infusion rates of 30 to 50 mL/h. The rate of complications observed was 10.7% among all subjects. Documented complications included infiltration (n = 2), with an incidence of 6%, and thrombophlebitis (n = 1), with an incidence of 3%. There has been a long concern among healthcare providers, including nursing staff, in regard to pIV administration of prolonged 3% HTS infusion therapy. Our study indicates that peripheral administration of 3% HTS carries a low risk of minor, nonlimb, or life-threatening complications. Although central venous infusion may reduce the risk of these minor complications, it may increase the risk of more serious complications such as large vessel thrombosis, bloodstream infection, pneumothorax, and arterial injury. The concern regarding the risks of pIV administration of 3% HTS may be overstated and unfounded.
Biffi, Roberto; Pozzi, Simonetta; Bonomo, Guido; Della Vigna, Paolo; Monfardini, Lorenzo; Radice, Davide; Rotmensz, Nicole; Zampino, Maria Giulia; Fazio, Nicola; Orsi, Franco
2014-11-01
No randomized trials have so far investigated the cost effectiveness of different methods for implantation and use of central venous ports in oncology patients. Overall, 403 patients eligible for receiving intravenous chemotherapy for solid tumours were randomly assigned to implantation of a single type of port, either through a percutaneous landmark access to the internal jugular vein, an ultrasound (US)-guided access to the subclavian vein, or a surgical cut-down access through the cephalic vein at the deltoid-pectoralis groove. Insertion and maintenance costs were estimated by obtaining the charges for an average implant and use, while the costs of the management of complications were analytically assessed. The total cost was defined as the purchase cost plus the insertion cost plus the maintenance cost plus the cost of treatment of the complications, if any. A total of 401 patients were evaluable-132 with the internal jugular vein, 136 with the subclavian vein and 133 with the cephalic vein access. No differences were found for the rate of early complications. The US-guided subclavian insertion site had significantly lower failures. Infections occurred in 1, 3, and 3 patients (internal jugular, subclavian, and cephalic access, respectively; p = 0.464), whereas venous thrombosis was observed in 15, 8, and 11 patients, respectively (p = 0.272). Mean cost for purchase, implantation, diagnosis and treatment of complications in each patient was
Effect of changes in PCO2 and body positions on intraocular pressure during general anaesthesia.
Hvidberg, A; Kessing, S V; Fernandes, A
1981-08-01
Elevated arterial carbon dioxide tension, induced by the administration of CO2 via the respiratory air or by hypoventilation, entailed a gradual increase in the IOP in patients without eye diseases under general anaesthesia. A sudden cessation of CO2 administration or hyperventilation caused such a rapid, simultaneous fall in IOP to values below the initial level that the pressure variations must be of vascular nature, presumably related to changes in choroidal blood volume. The above-mentioned procedures always cause a change in the central venous pressure (CVP) simultaneously with the IOP changes. Alterations of the CVP induced by hydrostatic factors in postural changes, placing the head 15 degrees above or below the horizontal level while keeping the PaCO2 constant, caused IOP changes of the same configuration and magnitude as described above. It is concluded, therefore, that presumably the CO2-conditioned IOP changes are due predominantly to changes in central venous pressure, being one link in a CO2-conditioned action upon the general circulation, entailing passive secondary changes in the choroidal venous blood volume and thereby an influence upon the IOP. On the basis of the present results it appears rational to recommend hyperventilation to keep the PaCO2 between 25 and 30 mm and a 15 degree anti-Trendelenburg position in operations on the eye under general anaesthesia, since both procedures afford a low central venous pressure and consequently a low pressure in the posterior segment of the eye, with its attendant advantages as regards vitreous complications and the insertion of intraocular lenses. Owing to the risk of an unacceptable fall in BP in the combined procedure, a frequent checking of the BP is needed.
Principles of chronic venous access: recommendations based on the Roswell Park experience.
Sabel, M S; Smith, J L
1997-11-01
At Roswell Park Cancer Institute, we have seen a dramatic increase in the need for long-term venous access. Chronic venous catheters are an indispensible part of the treatment provided to oncology patients. Cancer patients are often at higher risk for complications secondary to their underlying disease and treatments. These risks may be minimized by paying close attention to several important aspects of central line placement. These include matching individual patient needs with the access device most suited to those needs, a thorough preoperative assessment, and the safest and most appropriate operative approach for placement. Likewise, the prompt recognition and treatment of complications when they do occur is crucial to the care of these patients. In order to optimize the care of patients with long-term venous access devices, we have reviewed our experience of over 700 vascular access consultations and offer the following recommendations.
2006-09-01
NM, Joyner MJ. Influence of increased central venous pressure on baroreflex control of sympathetic activity in humans. Am J Physiol Heart Circ Physiol...Arterial Pulse Pressure and Its Association With Reduced Stroke Volume During Progressive Central Hypovolemia Victor A. Convertino, PhD, William H...reduction of SV and change in MSNA during graded central hypovolemia in humans. Methods: After a 12-minute baseline data collection period, 13 men were
Long-term central venous access device selection.
Gabriel, Janice
Infusion therapy is often viewed as a means to an end - a way to administer medications and fluids. It is one of the few specialties that affect almost all areas of healthcare. Safe, effective and reliable vascular access should be the goal of every health professional who is starting a patient on a prescribed course of intravenous therapy, especially if that patient is undergoing a prolonged course. This article aims to refresh and update nurses' clinical knowledge of the detailed patient assessment required before choosing a central venous access device, as well as supporting a reduction in complications and earlier recognition of potential problems. It discusses clinical indications for devices, the range of long-term intravenous therapies that can be used, and patient assessment.
Risk factors for venous port migration in a single institute in Taiwan
2014-01-01
Background An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. Methods This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Results Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Conclusions Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor. PMID:24423026
NASA Astrophysics Data System (ADS)
Zhang, Xiancheng; Noda, Shigeho; Himeno, Ryutaro; Liu, Hao
2017-06-01
We present a novel methodology and strategy to predict pressures and flow rates in the global cardiovascular network in different postures varying from supine to upright. A closed-loop, multiscale mathematical model of the entire cardiovascular system (CVS) is developed through an integration of one-dimensional (1D) modeling of the large systemic arteries and veins, and zero-dimensional (0D) lumped-parameter modeling of the heart, the cardiac-pulmonary circulation, the cardiac and venous valves, as well as the microcirculation. A versatile junction model is proposed and incorporated into the 1D model to cope with splitting and/or merging flows across a multibranched junction, which is validated to be capable of estimating both subcritical and supercritical flows while ensuring the mass conservation and total pressure continuity. To model gravitational effects on global hemodynamics during postural change, a robust venous valve model is further established for the 1D venous flows and distributed throughout the entire venous network with consideration of its anatomically realistic numbers and locations. The present integrated model is proven to enable reasonable prediction of pressure and flow rate waveforms associated with cardiopulmonary circulation, systemic circulation in arteries and veins, as well as microcirculation within normal physiological ranges, particularly in mean venous pressures, which well match the in vivo measurements. Applications of the cardiovascular model at different postures demonstrate that gravity exerts remarkable influence on arterial and venous pressures, venous returns and cardiac outputs whereas venous pressures below the heart level show a specific correlation between central venous and hydrostatic pressures in right atrium and veins.
Ansari, Md Abu Masud; Kumar, Naveen; Kumar, Shailesh; Kumari, Sarita
2016-10-01
Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray showed coiling of guide wire in neck. CT Angiography showed guide wire coursing in between common carotid artery and internal jugular vein (IJV), closely abutting the wall of both vessels. The guide wire was coiled with end coursing behind the esophageal wall. Guide wire was removed under fluoroscopic guide manipulation under local anesthesia. We want to emphasize that even though CVC placement is common and simple procedure, serious complication can occur in hands of untrained operator. The procedure should be performed under supervision, if done by trainee. Force should never be applied to advance the guide wire if resistance is encountered.
The influence of the nasal mucosa and the carotid rete upon hypothalamic temperature in sheep
Baker, Mary Ann; Hayward, James N.
1968-01-01
1. In chronically-prepared sheep, intracranial temperatures were measured in the cavernous sinus among the vessels of the carotid rete and at the circle of Willis extravascularly, and in the preoptic area and in other brain stem regions. Extracranial temperatures were measured intravascularly in the carotid or internal maxillary arteries and on the nasal mucosa and the skin of the ear. 2. At 20° C ambient temperature, shifts in temperature of the hypothalamus and of other brain sites paralleled temperature shifts in the cerebral arterial blood which was cooler than central arterial blood. During periods of arousal and of paradoxical sleep, vasoconstriction of the nasal mucosa and the ear skin occurred and temperatures at the cerebral arteries and in the brain rose without a comparable rise in central arterial blood temperature. 3. Anaesthetic doses of barbiturate abolished the temperature oscillations in the cerebral arterial blood and the brain. When air was blown rapidly over the nasal mucosa in anaesthetized animals, temperatures dropped precipitously in the cavernous sinus, at the cerebral arteries, and in the brain, while central arterial temperature fell only slightly. Injections of latex into the facial venous system demonstrated a venous pathway from the nasal mucosa to the cavernous sinus. 4. When sheep were exposed to 45-50° C ambient temperature, respiratory rate increased 5-10 times and the temperature gradient between central and cerebral arterial blood widened. 5. It is concluded that venous blood returning from the nasal mucosa and the skin of the head to the cavernous sinus cools the central arterial blood in the carotid rete. This is an important factor in the maintenance of hypothalamic temperature in the wool-covered, long-nosed, panting sheep and undoubtedly affects hypothalamic thermoreceptors and temperature regulation in artiodactyls. PMID:5685288
[Continual venous haemofiltration in severe hypothermia].
Nielsen, Jane Stab; Gilsaa, Torben
2010-02-22
A seventy-year-old male was brought to the emergency department severely hypothermic with a core temperature of 27 degrees C. He had sustained circulation and was actively rewarmed for 6,5 hours using central veno-venous haemofiltration. The rewarming was uneventful and the patient was discharged without sequelae. This case is an example of efficient and fast rewarming of severe accidental hypothermia by use of CVVH - a method currently available at most intensive care units in Denmark.
Sakijan, A S; Zambahari, R; Annuar, Z; Yahya, O; Ali, J
1990-12-01
A successful retrieval of a detached segment of a CVP catheter by percutaneous right transfemoral venous route, using a Dotter intravascular retriever basket, is reported. The procedure was monitored under fluoroscopy. Only local anaesthesia, which was infiltrated around the puncture site, was given to the patient. No significant complication was encountered. Successful retrieval of the detached catheter fragment by percutaneous means obviates the need for thoracotomy.
Pentoxifylline for treating venous leg ulcers.
Jull, Andrew B; Arroll, Bruce; Parag, Varsha; Waters, Jill
2012-12-12
Healing of venous leg ulcers is improved by the use of compression bandaging but some venous ulcers remain unhealed, and some people are unsuitable for compression therapy. Pentoxifylline, a drug which helps blood flow, has been used to treat venous leg ulcers. To assess the effects of pentoxifylline (oxpentifylline or Trental 400) for treating venous leg ulcers, compared with a placebo or other therapies, in the presence or absence of compression therapy. For this fifth update we searched the Cochrane Wounds Group Specialised Register (searched 20 July 2012); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 7); Ovid MEDLINE (2010 to July Week 2 2012); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, July 19, 2012); Ovid EMBASE (2010 to 2012 Week 28); and EBSCO CINAHL (2010 to July 13 2012). Randomised trials comparing pentoxifylline with placebo or other therapy in the presence or absence of compression, in people with venous leg ulcers. One review author extracted and summarised details from eligible trials using a coding sheet. One other review author independently verified data extraction. No new trials were identified for this update. We included twelve trials involving 864 participants. The quality of trials was variable. Eleven trials compared pentoxifylline with placebo or no treatment. Pentoxifylline is more effective than placebo in terms of complete ulcer healing or significant improvement (RR 1.70, 95% CI 1.30 to 2.24). Pentoxifylline plus compression is more effective than placebo plus compression (RR 1.56, 95% CI 1.14 to 2.13). Pentoxifylline in the absence of compression appears to be more effective than placebo or no treatment (RR 2.25, 95% CI 1.49 to 3.39).More adverse effects were reported in people receiving pentoxifylline (RR 1.56, 95% CI 1.10 to 2.22). Nearly three-quarters (72%) of the reported adverse effects were gastrointestinal. Pentoxifylline is an effective adjunct to compression bandaging for treating venous ulcers and may be effective in the absence of compression. The majority of adverse effects were gastrointestinal disturbances.
Emergent Management of Postpartum Hemorrhage for the General and Acute Care Surgeon
2009-01-01
central intravenous access and arterial lines should be inserted for central venous pressure monitor- ing, additional fluid infusion, continuous blood...BioMed Central Page 1 of 12 (page number not for citation purposes) World Journal of Emergency Surgery Open AccessReview Emergent management of...2009 This article is available from: http://www.wjes.org/content/4/1/43 © 2009 Weisbrod et al; licensee BioMed Central Ltd. This is an Open Access
Venous thromboembolism in African-Americans: a literature-based commentary.
Hooper, W Craig
2010-01-01
Among the cardiovascular diseases and after ischemic heart disease and stroke, venous thromboembolism (VTE) is the third leading cause of death in the U.S. (3). Although VTE is seen across most ethnic groups in the U.S. as well as throughout the world, the rate varies. In the U.S., American Indians/Alaskan Natives as well as Asians have been reported to have a significantly lower rate of deep vein thrombosis (DVT) and pulmonary embolism (PE) as compared to blacks and whites. In sharp conrast blacks appear to have much higher rates than whites. Although these rate differences are thought in part by some to be attributable to disparities in diagnosis and care as well as genetics, it nevertheless is important to define as well as to understand the true incidence and impact so that both public health and clinical resources can be maximally utilized. The purpose of this commentary is to review the VTE burden in the U.S. with respect to ethnicity in terms of clinical demographics and genetics with particular emphasis on blacks. Copyright 2009. Published by Elsevier Ltd.
van der Kooi, Tjallie; Sax, Hugo; Pittet, Didier; van Dissel, Jaap; van Benthem, Birgit; Walder, Bernhard; Cartier, Vanessa; Clack, Lauren; de Greeff, Sabine; Wolkewitz, Martin; Hieke, Stefanie; Boshuizen, Hendriek; van de Kassteele, Jan; Van den Abeele, Annemie; Boo, Teck Wee; Diab-Elschahawi, Magda; Dumpis, Uga; Ghita, Camelia; FitzGerald, Susan; Lejko, Tatjana; Leleu, Kris; Martinez, Mercedes Palomar; Paniara, Olga; Patyi, Márta; Schab, Paweł; Raglio, Annibale; Szilágyi, Emese; Ziętkiewicz, Mirosław; Wu, Albert W; Grundmann, Hajo; Zingg, Walter
2018-01-01
To test the effectiveness of a central venous catheter (CVC) insertion strategy and a hand hygiene (HH) improvement strategy to prevent central venous catheter-related bloodstream infections (CRBSI) in European intensive care units (ICUs), measuring both process and outcome indicators. Adult ICUs from 14 hospitals in 11 European countries participated in this stepped-wedge cluster randomised controlled multicentre intervention study. After a 6 month baseline, three hospitals were randomised to one of three interventions every quarter: (1) CVC insertion strategy (CVCi); (2) HH promotion strategy (HHi); and (3) both interventions combined (COMBi). Primary outcome was prospective CRBSI incidence density. Secondary outcomes were a CVC insertion score and HH compliance. Overall 25,348 patients with 35,831 CVCs were included. CRBSI incidence density decreased from 2.4/1000 CVC-days at baseline to 0.9/1000 (p < 0.0001). When adjusted for patient and CVC characteristics all three interventions significantly reduced CRBSI incidence density. When additionally adjusted for the baseline decreasing trend, the HHi and COMBi arms were still effective. CVC insertion scores and HH compliance increased significantly with all three interventions. This study demonstrates that multimodal prevention strategies aiming at improving CVC insertion practice and HH reduce CRBSI in diverse European ICUs. Compliance explained CRBSI reduction and future quality improvement studies should encourage measuring process indicators.
Image recognition and consistency of response
NASA Astrophysics Data System (ADS)
Haygood, Tamara M.; Ryan, John; Liu, Qing Mary A.; Bassett, Roland; Brennan, Patrick C.
2012-02-01
Purpose: To investigate the connection between conscious recognition of an image previously encountered in an experimental setting and consistency of response to the experimental question.
Materials and Methods: Twenty-four radiologists viewed 40 frontal chest radiographs and gave their opinion as to the position of a central venous catheter. One-to-three days later they again viewed 40 frontal chest radiographs and again gave their opinion as to the position of the central venous catheter. Half of the radiographs in the second set were repeated images from the first set and half were new. The radiologists were asked of each image whether it had been included in the first set. For this study, we are evaluating only the 20 repeated images. We used the Kruskal-Wallis test and Fisher's exact test to determine the relationship between conscious recognition of a previously interpreted image and consistency in interpretation of the image.
Results. There was no significant correlation between recognition of the image and consistency in response regarding the position of the central venous catheter. In fact, there was a trend in the opposite direction, with radiologists being slightly more likely to give a consistent response with respect to images they did not recognize than with respect to those they did recognize.
Conclusion: Radiologists' recognition of previously-encountered images in an observer-performance study does not noticeably color their interpretation on the second encounter.
NASA Astrophysics Data System (ADS)
Li, Yan-Ming; Liang, Zhen-Zhen; Song, Chun-Lei
2016-05-01
To compare the effect of 3 kinds of different materials on the hemostasis of puncture site after central venous catheterization. Method: A selection of 120 patients with peripheral central venous catheter chemotherapy in the Affiliated Hospital of our university from January 2014 to April 2015, Randomly divided into 3 groups, using the same specification (3.5cm × 2cm) alginate gelatin sponge and gauze dressing, 3 kinds of material compression puncture point, 3 groups of patients after puncture 24 h within the puncture point of local blood and the catheter after the catheter 72 h within the catheter maintenance costs. Result: (1) The local infiltration of the puncture point in the 24 h tube: The use of alginate dressing and gelatin sponge hemostatic effect is better than that of compression gauze. The difference was statistically significant (P <0.05). Compared with gelatin sponge and alginate dressing hemostatic effect, The difference was not statistically significant. (2) Tube maintenance cost: Puncture point using gelatin sponge, The local maintenance costs of the catheter within 72 h after insertion of the tube are lowest, compared with alginate dressing and gauze was significant (P<0.05). Conclusion: The choice of compression hemostasis material for the puncture site after PICC implantation, using gelatin sponge and gauze dressing is more effective and economic.
Suria, Stéphanie; Wyniecki, Anne; Eghiaian, Alexandre; Monnet, Xavier; Weil, Grégoire
2014-01-01
Transpulmonary thermodilution allows the measurement of cardiac index for high risk surgical patients. Oncologic patients often have a central venous access (port-a-catheter) for chronic treatment. The validity of the measurement by a port-a-catheter of the absolute cardiac index and the detection of changes in cardiac index induced by fluid challenge are unknown. We conducted a monocentric prospective study. 27 patients were enrolled. 250 ml colloid volume expansions for fluid challenge were performed during ovarian cytoreductive surgery. The volume expansion-induced changes in cardiac index measured by transpulmonary thermodilution by a central venous access (CIcvc) and by a port-a-catheter (CIport) were recorded. 23 patients were analyzed with 123 pairs of measurements. Using a Bland and Altman for repeated measurements, the bias (lower and upper limits of agreement) between CIport and CIcvc was 0.14 (-0.59 to 0.88) L/min/m2. The percentage error was 22%. The concordance between the changes in CIport and CIcvc observed during volume expansion was 92% with an r = 0.7 (with exclusion zone). No complications (included sepsis) were observed during the follow up period. The transpulmonary thermodilution by a port-a-catheter is reliable for absolute values estimation of cardiac index and for measurement of the variation after fluid challenge. clinicaltrials.gov NCT02063009.
... pulmonary infarction) Lung or pleural cancer -- primary or secondary (metastatic, or from another site) Tear in a blood vessel when placing a central venous catheter or when associated with severe high blood pressure Tuberculosis
Safety of peripheral intravenous administration of vasoactive medication.
Cardenas-Garcia, Jose; Schaub, Karen F; Belchikov, Yuly G; Narasimhan, Mangala; Koenig, Seth J; Mayo, Paul H
2015-09-01
Central venous access is commonly performed to administer vasoactive medication. The administration of vasoactive medication via peripheral intravenous access is a potential method of reducing the need for central venous access. The aim of this study was to evaluate the safety of vasoactive medication administered through peripheral intravenous access. Over a 20-month period starting in September 2012, we monitored the use of vasoactive medication via peripheral intravenous access in an 18-bed medical intensive care unit. Norepinephrine, dopamine, and phenylephrine were all approved for use through peripheral intravenous access. A total of 734 patients (age 72 ± 15 years, male/female 398/336, SAPS II score 75 ± 15) received vasoactive medication via peripheral intravenous access 783 times. Vasoactive medication used was norepinephrine (n = 506), dopamine (n = 101), and phenylephrine (n = 176). The duration of vasoactive medication via peripheral intravenous access was 49 ± 22 hours. Extravasation of the peripheral intravenous access during administration of vasoactive medication occurred in 19 patients (2%) without any tissue injury following treatment, with local phentolamine injection and application of local nitroglycerin paste. There were 95 patients (13%) receiving vasoactive medication through peripheral intravenous access who eventually required central intravenous access. Administration of norepinephrine, dopamine, or phenylephrine by peripheral intravenous access was feasible and safe in this single-center medical intensive care unit. Extravasation from the peripheral intravenous line was uncommon, and phentolamine with nitroglycerin paste were effective in preventing local ischemic injury. Clinicians should not regard the use of vasoactive medication is an automatic indication for central venous access. © 2015 Society of Hospital Medicine.
2015-03-01
statistically significant increase in systemic vascular resistance compared to control, but not whole blood, with a concomitant decrease in cardiac...increasing blood pressure as well as sys- temic vascular resistance in a hypovolemic hemorrhagic swine model.18 The primary hypothesis of this study is...output, sys- temic vascular resistance , mixed venous oxygen satura- tion, central venous pressure, pulmonary artery pressure, and core temperature. The
Pant, Deepanjali; Narani, Krishan Kumar; Sood, Jayashree
2010-01-01
Significant venous air embolism may develop acutely during the perioperative period due to a number of causes such as during head and neck surgery, spinal surgery, improper central venous and haemodialysis catheter handling, etc. The current trend of using self collapsible intravenous (IV) infusion bags instead of the conventional glass or plastic bottles has several advantages, one of thaem being protection against air embolism. We present a 56-year-old man undergoing kidney transplantation, who developed a near fatal venous air embolism during volume resuscitation with normal saline in collapsible IV bags used with rapid infuser system. To our knowledge, this problem with collapsible infusion bags has not been reported earlier. PMID:20532073
Noyes, Adam M; Dickey, John
2017-05-01
Upper extremity deep venous thrombosis (UEDVT) involves thrombosis of the deep veins of the arm as they enter the thorax. They are increasing in frequency, largely due to the rising use of central venous catheters and implantable cardiac devices, and represent more than 10% of all DVT cases, Upper extremity deep venous thrombosis has been historically misunderstood when compared to lower extremity deep vein thrombosis (LEDVT). Their associated disease states may carry devastating complications, with mortality rates often higher than that of LEDVT. Thus, education on recognition, classification and management is critical to avoid long-term sequelae and mortality from UEDVT. [Full article available at http://rimed.org/rimedicaljournal-2017-05.asp].
Kranz, Peter G; Amrhein, Timothy J; Gray, Linda
2017-12-01
The objective of this study is to describe the anatomic and imaging features of CSF venous fistulas, which are a recently reported cause of spontaneous intracranial hypotension (SIH). We retrospectively reviewed the records of patients with SIH caused by CSF venous fistulas who received treatment at our institution. The anatomic details of each fistula were recorded. Attenuation of the veins involved by the fistula was compared with that of adjacent control veins on CT myelography (CTM). Visibility of the CSF venous fistula on CTM and a modified conventional myelography technique we refer to as dynamic myelography was also compared. Twenty-two cases of CSF venous fistula were identified. The fistulas were located between T4 and L1. Ninety percent occurred without a concurrent epidural CSF leak. In most cases (82%), the CSF venous fistula originated from a nerve root sleeve diverticulum. On CTM, the abnormal veins associated with the CSF venous fistula were seen in a paravertebral location in 45% of cases, centrally within the epidural venous plexus in 32%, and lateral to the spine in 23%. Differences in attenuation between the fistula veins and the control veins was highly statistically significant (p < 0.0001), with a threshold of 70 HU perfectly discriminating fistulas from normal veins in our series. When both CTM and dynamic myelography were performed, the fistula was identified on both modalities in 88% of cases. CSF venous fistulas are an important cause of SIH that can be detected on both CTM and dynamic myelograph y and may occur without an epidural CSF leak. Familiarity with the imaging characteristics of these lesions is critical to providing appropriate treatment to patients with SIH.
Tran, Hoang S; Burrows, Brian J; Zang, William A; Han, David C
2006-09-01
Peripherally inserted central venous catheter (PICC) lines have become a frequently used method of intravenous access for long-term administration of antibiotics, chemotherapy, and parenteral nutrition. Catheter-related complications involving the arterial tree are rare. We report a case of a 25-year-old woman with a history of difficult PICC line placement that presented with an arteriovenous fistula in the left arm. Duplex ultrasound confirmed the diagnosis of a brachial artery-to-brachial vein arteriovenous fistula (AVF), and the patient underwent surgical repair. To our knowledge, this is the first reported case of an AVF resulting from PICC line placement. Correction of AVF is indicated to alleviate symptoms as well as to prevent future complications.
Between the lines: The 50th anniversary of long-term central venous catheters.
Gow, Kenneth W; Tapper, David; Hickman, Robert O
2017-05-01
Tunneled central venous catheters (CVC) were developed five decades ago. Since then, several clinician-inventors have created a variety of catheters with different functions. Indeed, many catheters have been named after their inventor. Many have wondered who the inventors were of each catheter, and what specifically inspired their inventions. Many of these compelling stories have yet to be told. A literature review of common catheters and personal communication with inventors. Only first person accounts from inventors or those close to the invention were used. CVCs are now essential devices that have saved countless lives. Though the inventors have earned the honor of naming their catheters, it may be reasonable to consider more consistent terminology to describe these catheters to avoid confusion. Copyright © 2017 Elsevier Inc. All rights reserved.
Al-Shamma, Safa; Fox, Mark
2009-01-01
We present a complicated case of extensive intra-abdominal venous thrombosis manifesting with severe central abdominal discomfort following trivial blunt local trauma and discuss the therapeutic interventions that can be used in these cases.
Laparoscopic umbilical hernia repair in a cirrhotic patient with a peritoneovenous shunt.
Umemura, Akira; Suto, Takayuki; Sasaki, Akira; Fujita, Tomohiro; Endo, Fumitaka; Wakabayashi, Go
2015-05-01
A 62-year-old Japanese woman who had developed massive cirrhotic ascites was referred to our hospital for a peritoneovenous shunt implant. However, CT examination revealed an umbilical hernia that had not been observed before the peritoneovenous shunt was implanted. We decided to perform laparoscopic umbilical hernia repair to keep carbon dioxide from flowing backward into the central circulatory system. We first clamped the catheter and set the upper limit of the pneumoperitoneum pressure to 6 mmHg. The central venous pressure was also measured simultaneously. Mesh was then applied over the hernia and fixed by the double-crown technique. Finally, 1000-mL physiological saline was infused into the abdominal cavity while the pneumoperitoneum was slowly released. In this case, we safely performed laparoscopic umbilical hernia repair while making some alterations, specifically catheter clamping, reducing pneumoperitoneum pressure, monitoring central venous pressure, and infusing physiological saline. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
Central venous catheters - ports
... do any contact sports, such as soccer and football. Nothing will stick out of your skin when ... herein should not be used during any medical emergency or for the diagnosis or treatment of any ...
Walters, Elizabeth Lea; Morawski, Kyle; Dorotta, Ihab; Ramsingh, Davinder; Lumen, Kelly; Bland, David; Clem, Kathleen; Nguyen, H Bryant
2011-04-01
Patients who present to the emergency department (ED) with return of spontaneous circulation after cardiac arrest generally have poor outcomes. Guidelines for treatment can be complicated and difficult to implement. This study examined the feasibility of implementing a care bundle including therapeutic hypothermia (TH) and early hemodynamic optimization for comatose patients with return of spontaneous circulation after out-of-hospital cardiac arrest. The study included patients over a 2-year period in the ED and intensive care unit of an academic tertiary-care medical center. The first year (prebundle) provided a historical control, followed by a prospective observational period of bundle implementation during the second year. The bundle elements included (a) TH initiated; (b) central venous pressure/central venous oxygen saturation monitoring in 2 h; (c) target temperature in 4 h; (d) central venous pressure greater than 12 mmHg in 6 h; (e) MAP greater than 65 mmHg in 6 h; (f) central venous oxygen saturation greater than 70% in 6 h; (g) TH maintained for 24 h; and (h) decreasing lactate in 24 h. Fifty-five patients were enrolled, 26 patients in the prebundle phase and 29 patients in the bundle phase. Seventy-seven percent of bundle elements were completed during the bundle phase. In-hospital mortality in bundle compared with prebundle patients was 55.2% vs. 69.2% (P = 0.29). In the bundle patients, those patients who received all elements of the care bundle had mortality 33.3% compared with 60.9% in those receiving some of the bundle elements (P = 0.22). Bundle patients tended to achieve good neurologic outcome compared with prebundle patients, Cerebral Performance Category 1 or 2 in 31 vs. 12% patients, respectively (P = 0.08). Our study demonstrated that a post-cardiac arrest care bundle that incorporates TH and early hemodynamic optimization can be implemented in the ED and intensive care unit collaboratively and can achieve similar clinical benefits compared with those observed in previous clinical trials.
Trzeciak, Stephen; Jones, Alan E; Shapiro, Nathan I; Pusateri, Anthony E; Arnold, Ryan C; Rizzuto, Michael; Arora, Tanisha; Parrillo, Joseph E; Dellinger, R Phillip
2010-04-01
Coagulation activation is an integral part of sepsis pathogenesis. Experimental data suggest that endothelial exposure to hypoxia activates coagulation. We aimed to test the hypothesis that the quantity of exposure to global tissue hypoxia is associated with the degree of coagulation activation during early sepsis resuscitation. Prospective, multicenter cohort study. Emergency department and intensive care unit of three academic hospitals. Inclusion criteria were age older than 17, acute infection with two or more signs of systemic inflammation, hypotension despite fluid challenge (or lactate >4 mM), and continuous central venous oxygen saturation (Scvo2) monitoring for quantitative resuscitation. Exclusion criteria were anticoagulant or blood product administration. We recorded central venous oxygen saturation continuously for 0 to 6 hrs of resuscitation and calculated the area under the curve for central venous oxygen saturation <70%. We defined hypoxia exposure as exceeding the median area under the curve for the entire cohort. At 0, 6, and 24 hrs, we measured conventional coagulation biomarkers plus thrombin-antithrombin complex, plasmin-antiplasmin complex, tissue plasminogen activator, plasminogen activator inhibitor-1, protein C, antithrombin, and endothelial markers (E-selectin, intracellular adhesion molecule-1, thrombomodulin). We compared changes during 0 to 6 hrs and 0 to 24 hrs in biomarkers between hypoxia exposure and nonexposure groups. We enrolled 40 patients (60% requiring vasopressors; 30% mortality). We found that exposure to hypoxia alone was not associated with a significant degree of coagulation activation. However, in secondary analyses we found that exposure to arterial hypotension induced E-selectin and thrombin-antithrombin complex, whereas concomitant exposure to both hypotension and hypoxia was associated with amplification of E-selectin and thrombomodulin, and a reduction in protein C. In this sample of patients undergoing quantitative resuscitation for sepsis, we found that exposure to global tissue hypoxia (as quantified by low central venous oxygen saturation) was not associated with major coagulation activation. Further investigation to elucidate the clinical factors that trigger or intensify the procoagulant response to sepsis is warranted.
Pulmonary hemodynamics and gas exchange in off pump coronary artery bypass grafting.
Vedin, Jenny; Jensen, Ulf; Ericsson, Anders; Samuelsson, Sten; Vaage, Jarle
2005-10-01
To investigate the influence of cardiopulmonary bypass on pulmonary hemodynamics and gas exchange. Low risk patients admitted for elective coronary artery bypass grafting were randomized to either on (n=25) or off pump (n=25) surgery. Central hemodynamics, gas exchange, and venous admixture were studied during and up to 20 h after surgery. There was no difference in pulmonary vascular resistance index (P=0.16), right ventricular stroke work index (P>0.2), mean pulmonary artery pressure (P>0.2) or pulmonary capillary wedge pressure (P>0.2) between groups. Soon after surgery there was a tendency towards higher cardiac index (P=0.07) in the off pump group. Arterial oxygen tension (P>0.2), hematocrit (P>0.2), venous admixture (P>0.2), and arterial-venous oxygen content difference (P=0.12) did not differ between groups. This prospective, randomized study showed no difference in pulmonary hemodynamics, pulmonary gas exchange, and venous admixture, in low risk patients undergoing off pump compared to on pump coronary artery bypass surgery.
Baratloo, Alireza; Rahmati, Farhad; Rouhipour, Alaleh; Motamedi, Maryam; Gheytanchi, Elmira; Amini, Fariba; Safari, Saeed
2014-01-01
Objective: To determine the correlation between blood gas parameters and central venous pressure (CVP) in patients suffering from septic shock. Methods: Forty adult patients with diagnosis of septic shock who were admitted to the emergency department (ED) of Shohadaye Tajrish Hospital affiliated with Shahid Beheshti University of Medical Sciences, and met inclusion and exclusion criteria were enrolled. For all patients, sampling was done for venous blood gas analysis, serum sodium and chlorine levels. At the time of sampling; blood pressure, pulse rate and CVP were recorded. Correlation between blood gas parameters and hemodynamic indices were. Results: A significant direct correlation between CVP with anion gap (AG) and inversely with base deficit (BD) and bicarbonate. CVP also showed a relative correlation with pH, whereas it was not correlated with BD/ AG ratio and serum chlorine level. There was no significant association between CVP and clinical parameters including shock index (SI) and mean arterial pressure (MAP). Conclusion: It seems that some of non invasive blood gas parameters could be served as alternative to invasive measures such as CVP in treatment planning of patients referred to an ED with septic shock. PMID:27162870
Endovascular recanalization of a port catheter-associated superior vena cava syndrome.
Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter
2015-01-01
Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.
Central venous catheter - dressing change
... will need: Sterile gloves Cleaning solution A special sponge A special patch, called a Biopatch A clear ... around the catheter. Clean the skin with the sponge and cleaning solution. Air dry after cleaning. Place ...
Šálek, Miroslav E.; Zárybnická, Markéta
2015-01-01
Incubation is an energetically demanding process during which birds apply heat to their eggs to ensure embryonic development. Parent behaviours such as egg turning and exchanging the outer and central eggs in the nest cup affect the amount of heat lost to the environment from individual eggs. Little is known, however, about whether and how egg surface temperature and cooling rates vary among the different areas of an egg and how the arrangement of eggs within the clutch influences heat loss. We performed laboratory (using Japanese quail eggs) and field (with northern lapwing eggs) experiments using infrared imaging to assess the temperature and cooling patterns of heated eggs and clutches. We found that (i) the sharp poles of individual quail eggs warmed to a higher egg surface temperature than did the blunt poles, resulting in faster cooling at the sharp poles compared to the blunt poles; (ii) both quail and lapwing clutches with the sharp poles oriented towards the clutch centre (arranged clutches) maintained higher temperatures over the central part of the clutch than occurred in those clutches where most of the sharp egg poles were oriented towards the exterior (scattered clutches); and (iii) the arranged clutches of both quail and lapwing showed slower cooling rates at both the inner and outer clutch positions than did the respective parts of scattered clutches. Our results demonstrate that egg surface temperature and cooling rates differ between the sharp and blunt poles of the egg and that the orientation of individual eggs within the nest cup can significantly affect cooling of the clutch as a whole. We suggest that birds can arrange their eggs within the nest cup to optimise thermoregulation of the clutch. PMID:25658846
Šálek, Miroslav E; Zárybnická, Markéta
2015-01-01
Incubation is an energetically demanding process during which birds apply heat to their eggs to ensure embryonic development. Parent behaviours such as egg turning and exchanging the outer and central eggs in the nest cup affect the amount of heat lost to the environment from individual eggs. Little is known, however, about whether and how egg surface temperature and cooling rates vary among the different areas of an egg and how the arrangement of eggs within the clutch influences heat loss. We performed laboratory (using Japanese quail eggs) and field (with northern lapwing eggs) experiments using infrared imaging to assess the temperature and cooling patterns of heated eggs and clutches. We found that (i) the sharp poles of individual quail eggs warmed to a higher egg surface temperature than did the blunt poles, resulting in faster cooling at the sharp poles compared to the blunt poles; (ii) both quail and lapwing clutches with the sharp poles oriented towards the clutch centre (arranged clutches) maintained higher temperatures over the central part of the clutch than occurred in those clutches where most of the sharp egg poles were oriented towards the exterior (scattered clutches); and (iii) the arranged clutches of both quail and lapwing showed slower cooling rates at both the inner and outer clutch positions than did the respective parts of scattered clutches. Our results demonstrate that egg surface temperature and cooling rates differ between the sharp and blunt poles of the egg and that the orientation of individual eggs within the nest cup can significantly affect cooling of the clutch as a whole. We suggest that birds can arrange their eggs within the nest cup to optimise thermoregulation of the clutch.
Locating the optimal internal jugular target site for central venous line placement.
Giordano, Chris R; Murtagh, Kevin R; Mills, Jaime; Deitte, Lori A; Rice, Mark J; Tighe, Patrick J
2016-09-01
Historically, the placement of internal jugular central venous lines has been accomplished by using external landmarks to help identify target-rich locations in order to steer clear of dangerous structures. This paradigm is largely being displaced, as ultrasound has become routine practice, raising new considerations regarding target locations and risk mitigation. Most human anatomy texts depict the internal jugular vein as a straight columnar structure that exits the cranial vault the same size that it enters the thoracic cavity. We dispute the notion that the internal jugulars are cylindrical columns that symmetrically descend into the thoracic cavity, and purport that they are asymmetric conical structures. The primary aim of this study was to evaluate 100 consecutive adult chest and neck computed tomography exams that were imaged at an inpatient hospital. We measured the internal jugular on the left and right sides at three different levels to look for differences in size as the internal jugular descends into the thoracic cavity. We revealed that as the internal jugular descends into the thorax, the area of the vessel increases and geometrically resembles a conical structure. We also reconfirmed that the left internal jugular is smaller than the right internal jugular. Understanding that the largest target area for central venous line placement is the lower portion of the right internal jugular vein will help to better target vascular access for central line placement. This is the first study the authors are aware of that depicts the internal jugular as a conical structure as opposed to the commonly depicted symmetrical columnar structure frequently illustrated in anatomy textbooks. This target area does come with additional risk, as the closer you get to the thoracic cavity, the greater the chances for lung injury. Copyright © 2016 Elsevier Inc. All rights reserved.
Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H
2017-12-01
Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.
Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra
2014-01-01
Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.
Tardáguila, A R; Del Cañizo, A; Santos, M M; Fanjul, M; Corona, C; Zornoza, M; Parente, A; Carrera, N; Beléndez, C; Cerdá, J; Saavedra, J; Molina, E; García-Casillas, M A; Peláez, D
2011-10-01
Long-term indwelling central venous access devices are frequently used in pediatric patients. Their main complication is infection, that can even mean their removal. We try to identify the risk factors really involved in this complication and in their removal. We have made a retrospective review of 120 oncologic pediatric patients who received a central venous device between 2003 and 2009. We searched for epidemiologic, clinic, microbiologic and surgical risk factors. We made a comparative data analysis among: GROUP A, children who suffered device infection, GROUP B the others. Group A was divided into early infection (first month after implantation)/late infection, removed/not removed. Data were analized with statistical program SPSS. 29 suffered from leukemia, 19 from lymphoma and the main part, 72, from solid tumour. 31% experienced infection (GROUP A), being early in the 36% of them. 16% had to be withdrawn. Data analysis revealed statistical association with the age (p=0.015) and with the reception of chemiotherapic treatment the week before the surgical insertion. The rest of the studied factors did not revealed a real association, but could be guess a relationship among infection and leukemia, subclavian catheters, those patients whose deviced was introduced using a guide over a previous catheter and also transplanted. Related to early infection the only associateon founded was with the subclavian access (p=0.018). In conclusion, in our serie long-term central venous access infection was more frequent in the younger patients and also in those who had received chemotherapy the week before the catheter implantation. The tendency towards infection in leukemia, transplanted and subclavian carriers has to be studied in a prospective way with a larger number of oncologic children.
Percutaneous Treatment of Central Venous Stenosis in Hemodialysis Patients: Long-Term Outcomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young Chul; Won, Jong Yun, E-mail: jywon@yumc.yonsei.ac.kr; Choi, Sun Young
2009-03-15
The purpose of this study was to evaluate the long-term outcomes of endovascular treatment of central venous stenosis in patients with arteriovenous fistulas (AVFs) for hemodialysis. Five hundred sixty-three patients with AVFs who were referred for a fistulogram were enrolled in this study. Among them, 44 patients showed stenosis (n = 35) or occlusions (n = 9) in the central vein. For the initial treatment, 26 patients underwent percutaneous transluminal angioplasty (PTA) and 15 patients underwent stent placements. Periods between AVF formation and first intervention ranged from 3 to 144 months. Each patient was followed for 14 to 60 months.more » Procedures were successful in 41 of 44 patients (93.2%). Primary patency rates for PTA at 12 and 36 months were 52.1% and 20.0%, and assisted primary patency rates were 77.8% and 33.3%, respectively. Primary patency rates for stent at 12 and 36 months were 46.7% and 6.7%, and assisted primary patency rates were 60.0% and 20.0%, respectively. Fifteen of 26 patients with PTAs underwent repeated interventions because of restenosis. Fourteen of 15 patients with a stent underwent repeated interventions because of restenosis and combined migration (n = 1) and shortening (n = 6) of the first stent. There was no significant difference in patency between PTAs and stent placement (p > 0.05). Average AVF patency duration was 61.8 months and average number of endovascular treatments was 2.12. In conclusion, endovascular treatments of central venous stenosis could lengthen the available period of AVFs. There was no significant difference in patency between PTAs and stent placement.« less
Suria, Stéphanie; Wyniecki, Anne; Eghiaian, Alexandre; Monnet, Xavier; Weil, Grégoire
2014-01-01
Background Transpulmonary thermodilution allows the measurement of cardiac index for high risk surgical patients. Oncologic patients often have a central venous access (port-a-catheter) for chronic treatment. The validity of the measurement by a port-a-catheter of the absolute cardiac index and the detection of changes in cardiac index induced by fluid challenge are unknown. Methods We conducted a monocentric prospective study. 27 patients were enrolled. 250 ml colloid volume expansions for fluid challenge were performed during ovarian cytoreductive surgery. The volume expansion-induced changes in cardiac index measured by transpulmonary thermodilution by a central venous access (CIcvc) and by a port-a-catheter (CIport) were recorded. Results 23 patients were analyzed with 123 pairs of measurements. Using a Bland and Altman for repeated measurements, the bias (lower and upper limits of agreement) between CIport and CIcvc was 0.14 (−0.59 to 0.88) L/min/m2. The percentage error was 22%. The concordance between the changes in CIport and CIcvc observed during volume expansion was 92% with an r = 0.7 (with exclusion zone). No complications (included sepsis) were observed during the follow up period. Conclusions The transpulmonary thermodilution by a port-a-catheter is reliable for absolute values estimation of cardiac index and for measurement of the variation after fluid challenge. Trial Registration clinicaltrials.gov NCT02063009 PMID:25136951
Lanspa, Michael J; Brown, Samuel M; Hirshberg, Eliotte L; Jones, Jason P; Grissom, Colin K
2012-12-01
Volume expansion is a common therapeutic intervention in septic shock, although patient response to the intervention is difficult to predict. Central venous pressure (CVP) and shock index have been used independently to guide volume expansion, although their use is questionable. We hypothesize that a combination of these measurements will be useful. In a prospective, observational study, patients with early septic shock received 10-mL/kg volume expansion at their treating physician's discretion after brief initial resuscitation in the emergency department. Central venous pressure and shock index were measured before volume expansion interventions. Cardiac index was measured immediately before and after the volume expansion using transthoracic echocardiography. Hemodynamic response was defined as an increase in a cardiac index of 15% or greater. Thirty-four volume expansions were observed in 25 patients. A CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less individually had a good negative predictive value (83% and 88%, respectively). Of 34 volume expansions, the combination of both a high CVP and a low shock index was extremely unlikely to elicit hemodynamic response (negative predictive value, 93%; P = .02). Volume expansion in patients with early septic shock with a CVP of 8 mm Hg or greater and a shock index of 1 beat min(-1) mm Hg(-1) or less is unlikely to lead to an increase in cardiac index. Copyright © 2012 Elsevier Inc. All rights reserved.
Chu, E; Haller, D; Cartwright, T; Twelves, C; Cassidy, J; Sun, W; Saif, M W; McKenna, E; Lee, S; Schmoll, H-J
2014-03-18
Central venous access devices in fluoropyrimidine therapy are associated with complications; however, reliable data are lacking regarding their natural history, associated complications and infusion pump performance in patients with metastatic colorectal cancer. We assessed device placement, use during treatment, associated clinical outcomes and infusion pump performance in the NO16966 trial. Device replacement was more common with FOLFOX-4 (5-fluorouracil (5-FU)+oxaliplatin) than XELOX (capecitabine+oxaliplatin) (14.1% vs 5.1%). Baseline device-associated events and post-baseline removal-/placement-related events occurred more frequently with FOLFOX-4 than XELOX (11.5% vs 2.4% and 8.5% vs 2.1%). Pump malfunctions, primarily infusion accelerations in 16% of patients, occurred within 1.6-4.3% of cycles. Fluoropyrimidine-associated grade 3/4 toxicity was increased in FOLFOX-4-treated patients experiencing a malfunction compared with those who did not (97 out of 155 vs 452 out of 825 patients), predominantly with increased grade 3/4 neutropenia (53.5% vs 39.8%). Febrile neutropenia rates were comparable between patient cohorts±malfunction. Efficacy outcomes were similar in patient cohorts±malfunction. Central venous access device removal or replacement was common and more frequent in patients receiving FOLFOX-4. Pump malfunctions were also common and were associated with increased rates of grade 3/4 haematological adverse events. Oral fluoropyrimidine-based regimens may be preferable to infusional 5-FU based on these findings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk
PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less
Sato, Junya; Kumagai, Masumi; Kato, Kenichi; Akahane, Akio; Suzuki, Michiko; Kashiwaba, Masahiro; Sone, Miyuki; Kudo, Kenzo
2014-08-01
Subcutaneous implantation type central venous ports(CV ports)are used in chemotherapy. Here, we prospectively examined the frequency of CV port-related infections when the disinfectant was changed from 10% povidone iodine to 1% chlorhexidine ethanol or 70% ethanol. The subjects were patients with malignant tumors, who had newly been implanted with CV ports. We examined CV port-related infections at 1 week after CV port implantation and every 2 weeks thereafter, following sterilization upon insertion of a Huber needle to the CV port. CV port evulsion due to CV port-related infection was noted in 3 patients(4.8%)in whom 15%chlorhexidine ethanol was used(n=62)and in 2 patients(3.3%)in whom 70% ethanol was used(n=60). Infection rates per 1,000 days of CV port use were 1.48% and 1.01%, respectively. Thus, the outcomes of sterilization using 1% chlorhexidine ethanol and 70% ethanol did not differ significantly from those on using 10% povidone iodine for sterilization, based on preliminary results at our institution(3 of 59 patients[5.1%]had port evulsion due to CV port-related infection and the infection rate per 1,000 days of CV port use was 1.47%, Akahane et al, 2012). Chlorhexidine ethanol and ethanol are very convenient to use because they dry quickly and do not need discoloration. Accordingly, chlorhexidine ethanol and ethanol might be useful in CV port management.
Perivascular fluid cuffs decrease lung compliance by increasing tissue resistance.
Lowe, Kevin; Alvarez, Diego F; King, Judy A; Stevens, Troy
2010-06-01
Lung inflammation causes perivascular fluid cuffs to form around extra-alveolar blood vessels; however, the physiologic consequences of such cuffs remain poorly understood. Herein, we tested the hypothesis that perivascular fluid cuffs, without concomitant alveolar edema, are sufficient to decrease lung compliance. Prospective, randomized, controlled study. Research laboratory. One hundred twenty male CD40 rats. To test this hypothesis, the plant alkaloid thapsigargin was used to activate store-operated calcium entry and increase cytosolic calcium in endothelium. Thapsigargin was infused into a central venous catheter of intact, sedated, and mechanically ventilated rats. Static and dynamic lung mechanics and hemodynamics were measured continuously. Thapsigargin produced perivascular fluid cuffs along extra-alveolar vessels but did not cause alveolar flooding or blood gas abnormalities. Lung compliance dose-dependently decreased after thapsigargin infusion, attributable to an increase in tissue resistance that was attributed to increased tissue damping and tissue elastance. Airway resistance was not changed. Neither central venous pressure nor left ventricular end diastolic pressure was altered by thapsigargin. Heart rate did not change, although thapsigargin decreased left ventricular systolic function sufficient to reduce cardiac output by 50%. Infusion of the type 4 phosphodiesterase inhibitor, rolipram, prevented thapsigargin from inducing perivascular cuffs and decreasing lung compliance. Rolipram also normalized pressure over time and corrected the deficit in cardiac output. Our findings resolve for the first time that perivascular cuff formation negatively impacts mechanical coupling between the bronchovascular bundle and the lung parenchyma, decreasing lung compliance without impacting central venous pressure.
das Graças C de Souza, Maria; Cyrino, Fatima Zga; de Carvalho, Jorge J; Blanc-Guillemaud, Vanessa; Bouskela, Eliete
2018-05-01
To assess protective effects of micronized purified flavonoid fraction (MPFF) on microcirculation in an original chronic model of hind limb venous hypertension with low blood flow in small animals. Vein ligatures were performed on male hamsters, as follows: A-right femoral vein; A + B-right femoral vein and its right branch; A + C-right femoral vein and its left branch; A + B + C-right femoral and its right and left branches; D-external right iliac vein. In sham operated groups, similar vascular dissections were performed without ligatures. Superficial (epigastric) and central (jugular) venous pressure evaluations were made during a 10 week period. Hamsters subjected to A + B + C and D ligatures were selected for leukocyte rolling and sticking, functional capillary density (FCD), and venular and arteriolar diameter observations. D ligature was selected to evaluate pharmacological treatment efficacy. MPFF (100 mg/kg), concomitant active flavonoids of MPFF (diosmetin, hesperidin, linarin, and isorhoifolin) (10 mg/kg), diosmin (100 mg/kg) or drug vehicle were administered orally during 2 weeks before vein ligature and 6 weeks thereafter. A, A + B and A + C models maintained venous return through collaterals. From the 2 nd to the 10 th weeks after vein ligatures, A + B + C and D models elicited a progressive increase of superficial venous pressure (3.83 ± 0.65 vs. 8.56 ± 0.72 mmHg, p < .001 and 4.13 ± 0.65 vs. 9.35 ± 0.65 mmHg, p < .001, respectively) with significant changes to the microcirculation. As D model significantly increased superficial venous pressure without affecting central venous pressure, it was used to evaluate the long-term effects of treatment. Compared with vehicle, MPFF, concomitant active flavonoids of MPFF, and diosmin, significantly decreased leukocyte-endothelium interaction and prevented FCD reduction. Only MPFF significantly prevented venular enlargement as observed in the vehicle treated group. MPFF was more effective than diosmin in improving all microvascular variables. The superiority of MPFF over diosmin alone can be explained by the synergistic beneficial effects of the association between diosmin and active flavonoids of MPFF. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.
Rogers, Mary A M; Blumberg, Neil; Bernstein, Steven J; Flanders, Scott A; Chopra, Vineet
2016-12-01
Mechanisms of red blood cell delivery and their contribution to the incidence of venous thromboembolism are not well understood in the clinical setting. We assessed whether red blood cell transfusion through peripherally inserted central catheters (PICCs) affects the risk of venous thromboembolism compared with transfusion through non-PICC devices. We implemented a prospective study between Jan 1, 2013, and Sept 12, 2015, in patients (age ≥18 years) admitted to a general medicine ward or intensive care unit who received a PICC for any reason during clinical care in 47 hospitals in Michigan, USA, with a maximum follow-up of 70 days. The exposure of interest was route of red blood cell transfusion. The primary outcome was symptomatic, radiographically confirmed, deep-vein thrombosis in the arm or leg or pulmonary embolism. We used Cox proportional hazards regression for analyses. Venous thromboembolism developed in 482 (5%) of 10 604 patients with PICCs. Of 788 patients who received a red blood cell transfusion through a multi-lumen PICC, 61 had venous thromboembolism. The adjusted hazard ratio (HR) for venous thromboembolism in all patients whose transfusions were administered through a multi-lumen PICC was 1·96 (95% CI 1·47-2·61; p<0·0001) compared with patients not receiving a transfusion, and was 1·79 (1·09-2·95; p=0·022) compared with patients transfused through a peripheral intravenous line. Compared with delivery through a peripheral intravenous line, venous thromboembolism risk was not elevated if transfusions were delivered through a single-lumen PICC (HR 0·98, 95% CI 0·44-2·14; p=0·95) or central venous catheter (1·50, 0·77-2·91; p=0·23). For every red blood cell unit transfused through a PICC, there was a significantly increased risk of venous thromboembolism (adjusted HR 1·24, 95% CI 1·01-1·52; p=0·037). Patients who received a transfusion through a PICC in the left arm were significantly more likely to develop a deep-vein thrombosis in the ipsilateral arm compared with the contralateral side (HR 23·44, 95% CI 2·96-185·83; p=0·0028). Similarly, patients transfused through a right-sided PICC were more likely to develop deep-vein thrombosis in the ipsilateral arm (HR 3·37, 95% CI 1·02-11·14; p=0·047). Red blood cell delivery through a multi-lumen PICC is associated with a greater risk of thrombosis than transfusion through a peripheral intravenous catheter. Careful monitoring for venous thromboembolism when transfusing red blood cells through multi-lumen PICCs seems necessary. Blue Cross Blue Shield of Michigan and Blue Care Network, as part of the BCBSM Value Partnerships program. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Antigravity suit used for neurosurgical operations in sitting position].
Szpiro-Zurkowska, A; Milczarek, Z; Marchel, A; Jagielski, J
1996-01-01
The aviator's antigravity suit (G-suit) was used for 40 operations on neurosurgical patients operated on in sitting position. The G-suit was filled with air to 0.2 atmosphere (20 kPa) pressure in 26 cases, and 0.3 atm. (30 kPa) in 14 cases. In all cases G-suit filling was followed by central venous pressure rise and mean arterial pressure rise. Venous air embolism was found in 5 (12.5%) patients. No other complications connected with the use of G-suit were observed.
Wang, X; Henzler, T; Gawlitza, J; Diehl, S; Wilhelm, T; Schoenberg, S O; Jin, Z Y; Xue, H D; Smakic, A
2016-11-01
Dynamic volume perfusion CT (dVPCT) provides valuable information on tissue perfusion in patients with hepatocellular carcinoma (HCC) and pancreatic cancer. However, currently dVPCT is often performed in addition to conventional CT acquisitions due to the limited morphologic image quality of dose optimized dVPCT protocols. The aim of this study was to prospectively compare objective and subjective image quality, lesion detectability and radiation dose between mean temporal arterial (mTA) and mean temporal portal venous (mTPV) images calculated from low dose dynamic volume perfusion CT (dVPCT) datasets with linearly blended 120-kVp arterial and portal venous datasets in patients with HCC and pancreatic cancer. All patients gave written informed consent for this institutional review board-approved HIPAA compliant study. 27 consecutive patients (18 men, 9 women, mean age, 69.1 years±9.4) with histologically proven HCC or suspected pancreatic cancer were prospectively enrolled. The study CT protocol included a dVPCT protocol performed with 70 or 80kVp tube voltage (18 spiral acquisitions, 71.2s total acquisition times) and standard dual-energy (90/150kVpSn) arterial and portal venous acquisition performed 25min after the dVPCT. The mTA and mTPV images were manually reconstructed from the 3 to 5 best visually selected single arterial and 3 to 5 best single portal venous phases dVPCT dataset. The linearly blended 120-kVp images were calculated from dual-energy CT (DECT) raw data. Image noise, SNR, and CNR of the liver, abdominal aorta (AA) and main portal vein (PV) were compared between the mTA/mTPV and the linearly blended 120-kVp dual-energy arterial and portal venous datasets, respectively. Subjective image quality was evaluated by two radiologists regarding subjective image noise, sharpness and overall diagnostic image quality using a 5-point Likert Scale. In addition, liver lesion detectability was performed for each liver segment by the two radiologists using the linearly blended120-kVp arterial and portal venous datasets as the reference standard. Image noise, SNR and CNR values of the mTA and mTPV were significantly higher when compared to the corresponding linearly blended arterial and portal venous 120-kVp datasets (all p<0.001) except for image noise within the PV in the portal venous phases (p=0.136). image quality of mTA and mTPV were rated significantly better when compared to the linearly blended 120-kVp arterial and portal venous datasets. Both readers were able to detect all liver lesions found on the linearly blended 120-kVp arterial and portal venous datasets using the mTA and mTPV datasets. The effective radiation dose of the dVPCT was 27.6mSv for the 80kVp protocol and 14.5mSv for the 70kVp protocol. The mean effective radiation dose for the linearly blended 120-kVp arterial and portal venous CT protocol together of the upper abdomen was 5.60mSv±1.48mSv. Our preliminary data suggest that subjective and objective image quality of mTA and mTPV datasets calculated from low-kVp dVPCT datasets is non-inferior when compared to linearly blended 120-kVp arterial and portal venous acquisitions in patients with HCC and pancreatic cancer. Thus, dVPCT could be used as a stand-alone imaging technique without additionally performed conventional arterial and portal venous CT acquisitions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Jaffer, Usman; Normahani, Pasha; Lackenby, Kimberly; Aslam, Mohammed; Standfield, Nigel J
2015-01-01
Duplex ultrasound measurement of reflux time is central to the diagnosis of venous incompetence. We have developed an assessment tool for Duplex measurement of venous reflux for both simulator and patient-based training. A novel assessment tool, Venous Duplex Ultrasound Assessment of Technical Skills (V-DUOSATS), was developed. A modified DUOSATS was used for simulator training. Participants of varying skill level were invited to viewed an instructional video and were allowed ample time to familiarize with the Duplex equipment. Attempts made by the participants were recorded and independently assessed by 3 expert assessors and 5 novice assessors using the modified V-DUOSATS. "Global" assessment was also done by expert assessors on a 4-point Likert scale. Content, construct, and concurrent validities as well as reliability were evaluated. Content and construct validity as well as reliability were demonstrated. Receiver operator characteristic analysis-established cut points of 19/22 and 21/30 were most appropriate for simulator and patient-based assessment, respectively. We have validated a novel assessment tool for Duplex venous reflux measurement. Further work is required to establish transference validity of simulator training to improve skill in scanning patients. We have developed and validated V-DUOSATS for simulator training. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Griffin, Andrew S; Gage, Shawn M; Lawson, Jeffrey H; Kim, Charles Y
2017-01-01
This study evaluated whether the use of a staged Hemodialysis Reliable Outflow (HeRO; Merit Medical, South Jordan, Utah) implantation strategy incurs increased early infection risk compared with conventional primary HeRO implantation. A retrospective review was performed of 192 hemodialysis patients who underwent HeRO graft implantation: 105 patients underwent primary HeRO implantation in the operating room, and 87 underwent a staged implantation where a previously inserted tunneled central venous catheter was used for guidewire access for the venous outflow component. Within the staged implantation group, 32 were performed via an existing tunneled hemodialysis catheter (incidentally staged), and 55 were performed via a tunneled catheter inserted across a central venous occlusion in an interventional radiology suite specifically for HeRO implantation (intentionally staged). Early infection was defined as episodes of bacteremia or HeRO infection requiring resection ≤30 days of HeRO implantation. For staged HeRO implantations, the median interval between tunneled catheter insertion and conversion to a HeRO graft was 42 days. The overall HeRO-related infection rate ≤30 days of implantation was 8.6% for primary HeRO implantation and 2.3% for staged implantations (P = .12). The rates of early bacteremia and HeRO resection requiring surgical resection were not significantly different between groups (P = .19 and P = .065, respectively), nor were age, gender, laterality, anastomosis to an existing arteriovenous access, human immunodeficiency virus status, diabetes, steroids, chemotherapy, body mass index, or graft location. None of the patient variables, techniques, or graft-related variables correlated significantly with the early infection rate. The staged HeRO implantation strategy did not result in an increased early infection risk compared with conventional primary implantation and is thus a reasonable strategy for HeRO insertion in hemodialysis patients with complex central venous disease. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Cardiovascular Deconditioning and Venous Air Embolism in Simulated Microgravity in the Rat
NASA Technical Reports Server (NTRS)
Robinson, R. R.; Doursout, M.-F.; Chelly, J. E.; Powell, M. R.; Little, T. M.; Butler,B. D.
1996-01-01
Astronauts conducting extravehicular activities undergo decompression to a lower ambient pressure, potentially resulting in gas bubble formation within the tissues and venous circulation. Additionally, exposure to microgravity produces fluid shifts within the body leading to cardiovascular deconditioning. A lower incidence of decompression illness in actual spaceflight compared with that in ground-based altitude chamber flights suggests that there is a possible interaction between microgravity exposure and decompression illness. The purpose of this study was to evaluate the cardiovascular and pulmonary effects of simulated hypobaric decompression stress using a tail suspension (head-down tilt) model of microgravity to produce the fluid shifts associated with weightlessness in conscious, chronically instrumented rats. Venous bubble formation resulting from altitude decompression illness was simulated by a 3-h intravenous air infusion. Cardiovascular deconditioning was simulated by 96 h of head-down tilt. Heart rate, mean arterial blood pressure, central venous pressure, left ventricular wall thickening and cardiac output were continuously recorded. Lung studies were performed to evaluate edema formation and compliance measurement. Blood and pleural fluid were examined for changes in white cell counts and protein concentration. Our data demonstrated that in tail-suspended rats subjected to venous air infusions, there was a reduction in pulmonary edema formation and less of a decrease in cardiac output than occurred following venous air infusion alone. Mean arterial blood pressure and myocardial wall thickening fractions were unchanged with either tail-suspension or venous air infusion. Heart rate decreased in both conditions while systemic vascular resistance increased. These differences may be due in part to a change or redistribution of pulmonary blood flow or to a diminished cellular response to the microvascular insult of the venous air embolization.
Stephenson, Elliot J P; Liem, Timothy K
2015-07-01
Clinical trials have shown that the presence of ultrasound-identified residual venous obstruction (RVO) on follow-up scanning may be associated with an elevated risk for recurrence, thus providing a potential tool to help determine the optimal duration of anticoagulant therapy. We performed a systematic review to evaluate the clinical utility of post-treatment duplex imaging in predicting venous thromboembolism (VTE) recurrence and in adjusting duration of anticoagulation. The Ovid MEDLINE Database, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Database of Abstracts of Reviews of Effects were queried for the terms residual thrombus or obstruction, duration of therapy, deep vein thrombosis, deep venous thrombosis, DVT, venous thromboembolism, VTE, antithrombotic therapy, and anticoagulation, and 228 studies were selected for review. Six studies determined the rate of VTE recurrence on the basis of the presence or absence of RVO. Findings on venous ultrasound scans frequently remained abnormal in 38% to 80% of patients, despite at least 3 months of therapeutic anticoagulation. In evaluating for VTE recurrence, the definition of RVO varied widely in the literature. Some studies have shown an association between RVO and VTE recurrence, whereas other studies have not. Overall, the presence of RVO is a mild risk factor for recurrence (odds ratio, 1.3-2.0), but only when surveillance imaging is performed soon after the index deep venous thrombosis (3 months). RVO is a mild risk factor for VTE recurrence. The presence or absence of ultrasound-identified RVO has a limited role in guiding the duration of therapeutic anticoagulation. Further research is needed to evaluate its utility relative to other known risk factors for VTE recurrence. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Gambardella, Ivancarmine; Gaudino, Mario; Ronco, Claudio; Lau, Christopher; Ivascu, Natalia; Girardi, Leonard N
2016-11-01
Acute kidney injury (AKI) in cardiac surgery has traditionally been linked to reduced arterial perfusion. There is ongoing evidence that central venous pressure (CVP) has a pivotal role in precipitating acute renal dysfunction in cardiac medical and surgical settings. We can regard this AKI driven by systemic venous hypertension as 'kidney congestive failure'. In the cardiac surgery population as a whole, when the CVP value reaches the threshold of 14 mmHg in postoperative period, the risk of AKI increases 2-fold with an odds ratio (OR) of 1.99, 95% confidence interval (95% CI) of 1.16-3.40. In cardiac surgery subsets where venous hypertension is a hallmark feature, the incidence of AKI is higher (tricuspid disease 30%, carcinoid valve disease 22%). Even in the non-chronically congested coronary artery bypass population, CVP measured 6 h postoperatively showed significant association to renal failure: risk-adjusted OR for AKI was 5.5 (95% CI 1.93-15.5; P = 0.001) with every 5 mmHg rise in CVP for patients with CVP <9 mmHg; for CVP increments of 5 mmHg above the threshold of 9 mmHg, the risk-adjusted OR for AKI was 1.3 (95% CI 1.01-1.65; P = 0.045). This and other clinical evidence are discussed along with the underlying pathophysiological mechanisms, involving the supremacy of volume receptors in regulating the autonomic output in hypervolaemia, and the regional effect of venous congestion on the nephron. The effect of CVP on renal function was found to be modulated by ventricular function class, aetiology and acuity of venous congestion. Evidence suggests that acute increases of CVP should be actively treated to avoid a deterioration of the renal function, particularly in patients with poor ventricular fraction. Besides, the practice of treating right heart failure with fluid loading should be avoided in favour of other ways to optimize haemodynamics in this setting, because of the detrimental effects on the kidney function. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Rossetti, Francesca; Pittiruti, Mauro; Lamperti, Massimo; Graziano, Ugo; Celentano, Davide; Capozzoli, Giuseppe
2015-01-01
The Italian Group for Venous Access Devices (GAVeCeLT) has carried out a multicenter study investigating the safety and accuracy of intracavitary electrocardiography (IC-ECG) in pediatric patients. We enrolled 309 patients (age 1 month-18 years) candidate to different central venous access devices (VAD) - 56 peripherally inserted central catheters (PICC), 178 short term centrally inserted central catheters (CICC), 65 long term VADs, 10 VADs for dialysis - in five Italian Hospitals. Three age groups were considered: A (<4 years, n = 157), B (4-11 years, n = 119), and C (12-18 years, n = 31). IC-ECG was applicable in 307 cases. The increase of the P wave on IC-ECG was detected in all cases but two. The tip of the catheter was positioned at the cavo-atrial junction (CAJ) (i.e., at the maximal height of the P wave on IC-ECG) and the position was checked during the procedure by fluoroscopy or chest x-ray, considering the CAJ at 1-2 cm (group A), 1.5-3 cm (group B), or 2-4 cm (group C) below the carina. There were no complications related to IC-ECG. The overall match between IC-ECG and x-ray was 95.8% (96.2% in group A, 95% in group B, and 96.8% in group C). In 95 cases, the IC-ECG was performed with a dedicated ECG monitor, specifically designed for IC-ECG (Nautilus, Romedex): in this group, the match between IC-ECG and x-ray was 98.8%. We conclude that the IC-ECG method is safe and accurate in the pediatric patients. The applicability of the method is 99.4% and its feasibility is 99.4%. The accuracy is 95.8% and even higher (98.8%) when using a dedicated ECG monitor.
Peltan, Ithan D.; Shiga, Takashi; Gordon, James A.; Currier, Paul F.
2015-01-01
Background Simulation training may improve proficiency at and reduces complications from central venous catheter (CVC) placement, but the scope of simulation’s effect remains unclear. This randomized controlled trial evaluated the effects of a pragmatic CVC simulation program on procedural protocol adherence, technical skill, and patient outcomes. Methods Internal medicine interns were randomized to standard training for CVC insertion or standard training plus simulation-based mastery training. Standard training involved a lecture, a video-based online module, and instruction by the supervising physician during actual CVC insertions. Intervention-group subjects additionally underwent supervised training on a venous access simulator until they demonstrated procedural competence. Raters evaluated interns’ performance during internal jugular CVC placement on actual patients in the medical intensive care unit. Generalized estimating equations were used to account for outcome clustering within trainees. Results We observed 52 interns place 87 CVCs. Simulation-trained interns exhibited better adherence to prescribed procedural technique than interns who received only standard training (p=0.024). There were no significant differences detected in first-attempt or overall cannulation success rates, mean needle passes, global assessment scores or complication rates. Conclusions Simulation training added to standard training improved protocol adherence during CVC insertion by novice practitioners. This study may have been too small to detect meaningful differences in venous cannulation proficiency and other clinical outcomes, highlighting the difficulty of patient-centered simulation research in settings where poor outcomes are rare. For high-performing systems, where protocol deviations may provide an important proxy for rare procedural complications, simulation may improve CVC insertion quality and safety. PMID:26154250
Risk of Infection Using Peripherally Inserted Central and Umbilical Catheters in Preterm Neonates.
Shalabi, Mohamed; Adel, Mohamed; Yoon, Eugene; Aziz, Khalid; Lee, Shoo; Shah, Prakesh S
2015-12-01
To compare the rates of catheter-associated bloodstream infection (CABSI) in preterm infants born at <30 weeks' gestation who received a peripherally inserted central catheter (PICC) versus an umbilical venous catheter (UVC) immediately after birth as their primary venous access. This retrospective matched cohort study examined data from infants born at <30 weeks' gestation and admitted between January 2010 and December 2013 to neonatal units in the Canadian Neonatal Network. Eligible infants who received a PICC on the first day after birth (day 1) were matched with 2 additional groups of infants, those who received a UVC on day 1 and those who received a UVC on day 1 that was then changed for a PICC after 4 days or more. The primary outcome was number of infants with CABSI per 1000 catheter days, which was compared between the 3 groups using multivariable analyses. Data from 540 eligible infants were reviewed (180 per group). There was no significant difference in infants with CABSI/1000 catheter days between the 3 groups (9.3 vs 7.8 vs 8.2/1000 catheter days, respectively; P > .05) despite lower rates of late onset sepsis in the group of infants who received only a UVC. There was no significant difference in the incidence of CABSI between very preterm neonates who received a PICC, UVC, or UVC followed by PICC as the primary mode of venous access after birth. A prospective randomized controlled trial is justified to further guide practice regarding primary venous access and reduction of infection. Copyright © 2015 by the American Academy of Pediatrics.
Neurological sequelae from brachiocephalic vein stenosis.
Herzig, David W; Stemer, Andrew B; Bell, Randy S; Liu, Ai-Hsi; Armonda, Rocco A; Bank, William O
2013-05-01
Stenosis of central veins (brachiocephalic vein [BCV] and superior vena cava) occurs in 30% of hemodialysis patients, rarely producing intracranial pathology. The authors present the first cases of BCV stenosis causing perimesencephalic subarachnoid hemorrhage and myoclonic epilepsy. In the first case, a 73-year-old man on hemodialysis presented with headache and blurry vision, and was admitted with presumed idiopathic intracranial hypertension after negative CT studies and confirmatory lumbar puncture. The patient mildly improved until hospital Day 3, when he experienced a seizure; emergency CT scans showed perimesencephalic subarachnoid hemorrhage. Cerebral angiography failed to find any vascular abnormality, but demonstrated venous congestion. A fistulogram found left BCV occlusion with jugular reflux. The occlusion could not be reopened percutaneously and required open fistula ligation. Postoperatively, symptoms resolved and the patient remained intact at 7-month follow-up. In the second case, a 67-year-old woman on hemodialysis presented with right arm weakness and myoclonic jerks. Admission MRI revealed subcortical edema and a possible dural arteriovenous fistula. Cerebral angiography showed venous engorgement, but no vascular malformation. A fistulogram found left BCV stenosis with jugular reflux, which was immediately reversed with angioplasty and stent placement. Postprocedure the patient was seizure free, and her strength improved. Seven months later the patient presented in myoclonic status epilepticus, and a fistulogram revealed stent occlusion. Angioplasty successfully reopened the stent and she returned to baseline; she was seizure free at 4-month follow-up. Central venous stenosis is common with hemodialysis, but rarely presents with neurological findings. Prompt recognition and endovascular intervention can restore normal venous drainage and resolve symptoms.
Farge, Dominique; Durant, Cecile; Villiers, Stéphane; Long, Anne; Mahr, Alfred; Marty, Michel; Debourdeau, Philippe
2010-04-01
Increased prevalence of Venous thromboembolism (VTE), as defined by deep-vein thrombosis (DVT), central venous catheter (CVC) related thrombosis or pulmonary embolism (PE) in cancer patients has become a major therapeutic issue. Considering the epidemiology and each national recommendations on the treatment of VTE in cancer patients, we analysed guidelines implementation in clinical practice. Thrombosis is the second-leading cause of death in cancer patients and cancer is a major risk factor of VTE, due to activation of coagulation, use of long-term CVC, the thrombogenic effects of chemotherapy and anti-angiogenic drugs. Three pivotal trials (CANTHANOX, LITE and CLOT) and several meta-analysis led to recommend the long term (3 to 6 months) use of LMWH during for treating VTE in cancer patients with a high level of evidence. The Italian Association of Medical Oncology (AIOM), the National Comprehensive Cancer Network (NCCN), the American Society of Clinical Oncology (ASCO), the French "Institut National du Cancer" (INCa), the European Society of Medical Oncology (ESMO) and the American College of Chest Physicians (ACCCP) have published specific guidelines for health care providers regarding the prevention and treatment of cancer-associated VTE. Critical appraisal of these guidelines, difficulties in implementation of prophylaxis regimen, tolerance and cost effectiveness of long term use of LMWH may account for large heterogenity in daily clinical practice. Homogenization of these guidelines in international consensus using an adapted independent methodological approach followed by educational and active implementation strategies at each national level would be very valuable to improve the care of VTE in cancer patients.
Vovenko, E P; Sokolova, I B; Loshchagin, O V
2002-03-01
Using oxygen microelectrodes, distribution of oxygen tension (pO2) has been studied in venules of the rat brain cortex at normobaric hyperoxia (spontaneous breathing with pure oxygen). It has been shown that inhalation of oxygen results in sharp increase of pO2 in majority of the venules under study. The pO2 distribution along the length of venous microvessels of 7-280 microns in diameter is best approximated by equation: pO2 = 76.44 e-0.0008D, n = 407. The pO2 distribution was characterised by extremely high pO2 values (180-240 mm Hg) in some minute venules. Heterogeneity of pO2 distribution in venous microvessels at hyperoxia was shown to be significantly increased. Profiles of pO2 between neighbouring arterioles and venules were for the first time measured. The data clearly evidenced that O2 diffusional shunting took place between cortical arterioles and venules, provided they were distanced from each other for not over 80-100 microns. Distribution of pO2 in venules has been shown to be dependent on the blood flow in the brain cortical microvessels.
Sand, L; Rizell, M; Houltz, E; Karlsen, K; Wiklund, J; Odenstedt Hergès, H; Stenqvist, O; Lundin, S
2011-10-01
It has been suggested that blood loss during liver resection may be reduced if central venous pressure (CVP) is kept at a low level. This can be achieved by changing patient position but it is not known how position changes affect portal (PVP) and hepatic (HVP) venous pressures. The aim of the study was to assess if changes in body position result in clinically significant changes in these pressures. We studied 10 patients undergoing liver resection. Mean arterial pressure (MAP) and CVP were measured using fluid-filled catheters, PVP and HVP with tip manometers. Measurements were performed in the horizontal, head up and head down tilt position with two positive end expiratory pressure (PEEP) levels. A 10° head down tilt at PEEP 5 cm H(2) O significantly increased CVP (11 ± 3 to 15 ± 3 mmHg) and MAP (72 ± 8 to 76 ± 8 mmHg) while head up tilt at PEEP 5 cm H(2) O decreased CVP (11 ± 3 to 6 ± 4 mmHg) and MAP (72 ± 8 to 63 ± 7 mmHg) with minimal changes in transhepatic venous pressures. Increasing PEEP from 5 to 10 resulted in small increases, around 1 mmHg in CVP, PVP and HVP. There was no significant correlation between changes in CVP vs. PVP and HVP during head up tilt and only a weak correlation between CVP and HVP by head down tilt. Changes of body position resulted in marked changes in CVP but not in HVPs. Head down or head up tilt to reduce venous pressures in the liver may therefore not be effective measures to reduce blood loss during liver surgery. 2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.
Effectiveness of electrocardiographic guidance in CVAD tip placement.
Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire
International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.
Veno-occlusive disease in snow leopards (Panthera uncia) from zoological parks.
Munson, L; Worley, M B
1991-01-01
Livers from 54 snow leopards, 4 days to 23 years old, that had died in 23 US zoos, were evaluated histopathologically to determine if the hepatic fibrosis, which has been noted to be prevalent in this species, was due to chronic active hepatitis from hepadnaviral infection, Ito cell proliferation, or hemosiderosis. Forty-two of 54 snow leopards had subintimal vascular fibrosis with partial or total occlusion of central and sublobular veins (veno-occlusive disease) of unknown origin. All 21 leopards older than 5 years were affected. Four leopards had chronic active hepatitis, and 12 leopards had cholangiohepatitis; but these lesions were not connected anatomically to central and sublobular venous fibrosis. Hepatocellular and Kupffer cell siderosis and Ito cell proliferation were prevalent and often coexisted with perisinusoidal, central, and sublobular venous fibrosis; but fibrosis was present in leopards without siderosis or Ito cell proliferation. The pattern and prevalence of veno-occlusive disease in these leopards was similar to that reported in captive cheetah (Acinonyx jubatus), suggesting that a common extrinsic factor may cause the majority of hepatic disease in these large felid animals in captivity.
Takada, Shigeki; Hojo, Masato; Takebe, Noriyoshi; Tanigaki, Kenji; Miyamoto, Susumu
2018-06-07
Hemangioblastomas (HBs) are benign vascular tumors of the central nervous system and histologically contain abundant microvessels. Therefore, they clinically exhibit vascular malformation-like characteristics. It has been described that endothelial-to-mesenchymal transition (EndMT) contributes to the pathogenesis of cerebral cavernous malformations. However, it remains unknown whether EndMT contributes to the pathogenesis of central nervous system HBs. The aim of our study was to investigate whether EndMT occurs in central nervous system HBs. Ten central nervous system HBs were immunohistochemically investigated. CD31 (an endothelial marker) and EndMT markers, such as α-smooth muscle actin (a mesenchymal marker) and CD44 (a mesenchymal stem cell marker), were expressed in the endothelial layer of microvessels in all cases. These findings suggest that endothelial cells (ECs) of microvessels in central nervous system HBs have acquired mesenchymal and stem-cell-like characteristics and undergone EndMT. In all cases, both ephrin-B2 and EphB4, which are not detected in adult normal brain vessels, were expressed in the endothelial layer of microvessels. These data suggest that ECs of microvessels in central nervous system HBs are immature or malformed cells and have both arterial and venous characteristics. This is the first report showing the possibility that EndMT contributes to the pathogenesis of central nervous system HBs. It is likely that ECs of microvessels in central nervous system HBs are immature or malformed cells and have both arterial and venous characteristics. EndMT is expected to be a new therapeutic target in central nervous system HBs. Copyright © 2018 Elsevier Inc. All rights reserved.
Lorenz, Udo; Hüttinger, Christian; Schäfer, Tina; Ziebuhr, Wilma; Thiede, Arnulf; Hacker, Jörg; Engelmann, Susanne; Hecker, Michael; Ohlsen, Knut
2008-03-01
The impact of the alternative sigma factor sigma B (SigB) on pathogenesis of Staphylococcus aureus is not conclusively clarified. In this study, a central venous catheter (CVC) related model of multiorgan infection was used to investigate the role of SigB for the pathogenesis of S. aureus infections and biofilm formation in vivo. Analysis of two SigB-positive wild-type strains and their isogenic mutants revealed uniformly that the wild-type was significantly more virulent than the SigB-deficient mutant. The observed difference in virulence was apparently not linked to the capability of the strains to form biofilms in vivo since wild-type and mutant strains were able to produce biofilm layers inside of the catheter. The data strongly indicate that the alternative sigma factor SigB plays a role in CVC-associated infections caused by S. aureus.
Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo
2017-01-01
Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens. PMID:28194286
Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo
2017-01-01
Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.
Hentrich, M; Schalk, E; Schmidt-Hieber, M; Chaberny, I; Mousset, S; Buchheidt, D; Ruhnke, M; Penack, O; Salwender, H; Wolf, H-H; Christopeit, M; Neumann, S; Maschmeyer, G; Karthaus, M
2014-05-01
Cancer patients are at increased risk for central venous catheter-related infections (CRIs). Thus, a comprehensive, practical and evidence-based guideline on CRI in patients with malignancies is warranted. A panel of experts by the Infectious Diseases Working Party (AGIHO) of the German Society of Hematology and Medical Oncology (DGHO) has developed a guideline on CRI in cancer patients. Literature searches of the PubMed, Medline and Cochrane databases were carried out and consensus discussions were held. Recommendations on diagnosis, management and prevention of CRI in cancer patients are made, and the strength of the recommendation and the level of evidence are presented. This guideline is an evidence-based approach to the diagnosis, management and prevention of CRI in cancer patients.
Bilateral Pneumothoraces Following Central Venous Cannulation
Pazos, F.; Masterson, K.; Inan, C.; Robert, J.; Walder, B.
2009-01-01
We report the occurrence of a bilateral pneumothoraces after unilateral central venous catheterization of the right subclavian vein in a 70-year-old patient. The patient had no history of pulmonary or pleural disease and no history of cardiothoracic surgery. Two days earlier, she had a median laparotomy under general and epidural anaesthesia. Prior to the procedure, the patient was hemodynamically stable and her transcutaneous oxygen saturation was 97% in room air. We punctured the right pleural space before cannulation of the right subclavian vein. After the procedure, the patient slowly became hemodynamically instable with respiratory distress. A chest radiograph revealed a complete left-side pneumothorax and a mild right-side pneumothorax. The right-side pneumothorax became under tension after left chest tube insertion. The symptoms finally resolved after insertion of a right chest tube. After a diagnostic work-up, we suspect a congenital “Buffalo chests” explaining bilateral pneumothoraces and a secondary tension pneumothorax. PMID:19901997
Funt, Samuel; Lerakis, Stamatios; McLean, Dalton S; Willis, Patrick; Book, Wendy; Martin, Randolph P
2010-04-01
A 33-year-old woman with a history of gestational trophoblastic disease presented for investigation of a right atrial mass. She had been receiving chemotherapy administered via a Port-a-Cath system for 2 months prior to presentation. On transesophageal echocardiography and magnetic resonance imaging, she was found to have a mass attached to the right atrial free wall, with a segment projecting across a patent foramen ovale. Because of the risk for an embolic event, the mass was surgically removed and the patent foramen ovale repaired. Pathology showed an organized thrombus. This case emphasizes the need for high suspicion for thrombus when a right atrial mass is found in a patient with a hypercoagulable state due to underlying malignancy who has a central venous catheter. Copyright 2010 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.
Influence of low and high pressure baroreceptors on plasma renin activity in humans
NASA Technical Reports Server (NTRS)
Mark, A. L.; Abboud, F. M.; Fitz, A. E.
1977-01-01
The effects of low and high pressure baroreceptors on plasma renin activity (immunoassay) were evaluated using graded lower body suction (LBS) in six healthy men. LBS at -10 and -20 mmHg for 10 min decreased central venous pressure without changing arterial pressure and thereby presumably reduced low but not high pressure baroreceptor inhibition of renin release. LBS at these levels produced forearm vasoconstriction, but did not increase renin. LBS at -40 mmHG decreased central venous and arterial pulse pressure and thus reduced both low and high pressure baroreceptor inhibition. LBS at this level produced forearm vasoconstriction and tachycardia and increased renin. In summary, reduction in low pressure baroreceptor inhibition in humans did not increase renin in the presence of physiological tonic inhibition from high pressure baroreceptors. Increases in renin did not occur until there was combined reduction of high and low pressure baroreceptor inhibition on plasma renin activity.
Jardim, Jaquelline Maria; Lacerda, Rúbia Aparecida; Soares, Naury de Jesus Danzi; Nunes, Bruna Kosar
2013-02-01
The aim of this study was to observe clinical procedures in order to evaluate the practices used for the control and prevention of bloodstream infections associated with short-term central venous catheters (BSI-ACVC). The study data came from 5877 assessments distributed among selected practices. The results revealed the following adherence rates among the practices selected: 91.6% for recording the indication and permanence time of the CVC, 51.5% for adhering to the care and maintenance of the dressing at the CVC insertion site and its devices, 10.7% for hand hygiene practices while performing procedures related to the CVC, and 0.0% for the practices related to the insertion of the central venous catheter (CVC). The results demonstrate the need for further elaboration of strategies that ensure sustainable compliance practices for prevention and control BSI-ACVC in the institution being assessed.
Rhodotorula fungemia of an intensive care unit patient and review of published cases.
Spiliopoulou, Anastasia; Anastassiou, Evangelos D; Christofidou, Myrto
2012-10-01
Rhodotorula species are commensal yeasts that have emerged as a cause of life-threatening fungemia in severely immunocompromised patients. A case of Rhodotorula mucilaginosa fungemia in a 48-year-old woman that had undergone consecutive abdominal surgeries due to ovarian cancer and bowel necrosis while she was receiving fluconazole prophylaxis is presented. Several risk factors were identified such as presence of central venous catheters, solid organ neoplasm, abdominal surgery and administration of antibiotics. Identification was performed using commercial systems. The yeast was resistant to fluconazole, posaconazole and voriconazole and to echinocandins, whereas MIC to amphotericin B was 1.5 mg/L. Furthermore, published cases of Rhodotorula spp fungemia during the last decade are reviewed. In conclusion, Rhodotorula spp must be considered a potential pathogen in patients with immunosupression and central venous catheters. Correct identification is mandatory for appropriate management, as Rhodotorula spp are resistant to antifungal agents, such as fluconazole and echinocandins.
Tam, John Kit Chung; Atasha, Asmat; Tan, Ann Kheng
2013-01-01
OBJECTIVES Iatrogenic subclavian artery puncture following central venous catheterization is a rare but potentially fatal complication. There are very few reports in the literature on this condition. We propose the use of video-assisted thoracic surgery (VATS) in the management of these injuries. METHODS The technique of VATS to manage subclavian artery injury was described. We presented the first reported case of successful repair of subclavian artery injury using VATS. RESULTS Using a two-incisional approach for VATS, the haemothorax was rapidly evacuated and the subclavian artery injury was successfully repaired using pledgetted sutures under direct thoracoscopic visualization. The patient had an uneventful postoperative recovery. CONCLUSIONS VATS can be successfully applied to repair subclavian artery injury. The advantages include rapid intrathoracic access, excellent thoracoscopic visualization of the thoracic inlet, and avoidance of the morbidity associated with open thoracotomy. PMID:23518293
Secola, Rita; Lewis, Mary Ann; Pike, Nancy; Needleman, Jack; Doering, Lynn
2012-01-01
Reducing or eliminating hospital acquired infections is a national quality of care priority. The majority of the 12,400 children diagnosed with cancer each year require long-term intravenous access to receive intensive and complex therapies. These children are at high risk for infection by nature of their disease and treatment, which often involves use of a central venous catheter (CVC). Throughout the nation, nurses assume frontline responsibility for safe, quality CVC care to minimize the risk of potentially life-threatening infections. Substantial financial and human costs are associated with CVC-related bloodstream infections, including prolonged hospital lengths of stay and increased care required to treat these infections. The purpose of this review of the literature is to summarize existing adult and pediatric data on CVC-related bloodstream infections and explore nursing models of CVC care that may improve pediatric oncology patient outcomes.
Air embolism after central venous catheterization.
Kashuk, J L; Penn, I
1984-09-01
Air embolism--the most dangerous complication of central venous catheterization--may occur in several ways. The most frequent is from disconnection of the catheter from the related intravenous tubing. An embolism may present with a sucking sound, tachypnea, air hunger, wheezing, hypotension and a "mill wheel" murmur. A later manifestation is severe pulmonary edema. In a review of 24 patients, the mortality was 50 per cent. Among the survivors, five (42 per cent) had neurologic damage. Immediate treatment includes placing the patient in the left lateral and Trendelenberg positions, administration of oxygen and aspiration of air from the heart. Cardiac massage and emergency cardiopulmonary bypass may be necessary. Most instances can be prevented by inserting the cannula with the patient in the Trendelenberg position, occluding the cannula hub except briefly while the catheter is inserted, fixation of the catheter hub to its connections and occlusive dressing over the track after removal of the catheter.
Cardiovascular reflexes during rest and exercise modified by gravitational stresses
NASA Astrophysics Data System (ADS)
Bonde-petersen, Flemming
The hypotheses tested were whether variations in central venous pressure via the low pressure baroreceptors would take over or modify the arterial baroreceptor function, and further to which extent local and "whole body" hydrostatic stresses influence blood flow distribution. We investigated total forearm and skin blood flow (venous occlusion plethysmography and 133-Xe clearance) and cardiac output (rebreathing method) among other parameters. Hypo-and hypergravitational stresses were simulated by LBNP, LBPP, water immersion and lowering of the arm. The changes in flow distribution in the arm were ascribed to arterial baroreceptor function and not to low pressure baroreceptor activity. The enhancement of venous return during water immersion increased exercise tolerance during heat stress presumably due both to increased stroke volume and decreased venous pooling. The response to sustained handgrip exercise during LBNP and LBPP was not different from control measurements and the effects explained by arterial baroreceptor function. Application of exercise and local hydrostatic stresses in combination with gravitational stresses represent an interesting model for further study of the mechanisms behind the distribution of cardiac output to the peripheral organs.
Elevated central venous pressure: a consequence of exercise training-induced hypervolemia?
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Mack, G. W.; Nadel, E. R.
1991-01-01
Resting blood volumes and arterial and central venous pressures (CVP) were measured in 14 men before and after exercise training to determine whether training-induced hypervolemia is accompanied by a change in total vascular capacitance. In addition, resting levels of plasma arginine vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (Ald), and norepinephrine (NE) were measured. The same measurements were conducted in seven subjects who did not undergo exercise and acted as controls. Exercise training consisted of 10 wk of controlled cycle exercise for 30 min/day, 4 days/wk at 75-80% of maximal O2 uptake (VO2max). A training effect was verified by a 20% increase in VO2max, a resting bradycardia, and a 9% increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased by 16% (P less than 0.05). The percent change in blood volume from before to after training was linearly related to the percent change in CVP (r = 0.903, P less than 0.05). As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was unchanged after exercise training. Plasma AVP, ANP, Ald, and NE were unaltered. Our results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance.
[Central venous catheter-related infections in critically ill patients].
Diener, J R; Coutinho, M S; Zoccoli, C M
1996-01-01
To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.
Shiono, Masatoshi; Takahashi, Shin; Takahashi, Masanobu; Yamaguchi, Takuhiro; Ishioka, Chikashi
2016-12-01
We conducted a nationwide questionnaire-based survey to understand the current situation regarding central venous port implantation in order to identify the ideal procedure. Questionnaire sheets concerning the number of implantation procedures and the incidence of complications for all procedures completed in 2012 were sent to 397 nationwide designated cancer care hospitals in Japan in June 2013. Venipuncture sites were categorized as chest, neck, upper arm, forearm, and others. Methods were categorized as landmark, cut-down, ultrasound-mark, real-time ultrasound guided, venography, and other groups. We received 374 responses (11,693 procedures) from 153 centers (38.5 %). The overall complication rates were 7.4 % for the chest (598/8,097 cases); 6.8 % for the neck (157/2325); 5.2 % for the upper arm (54/1,033); 7.3 % for the forearm (9/124); and 6.1 % for the other groups (7/114). Compared to the chest group, only the upper arm group showed a significantly lower incidence of complications (P = 0.010), and multivariate logistic regression (odds ratio 0.69; 95 % confidence interval 0.51-0.91; P = 0.008) also showed similar findings. Real-time ultrasound-guided puncture was most commonly used in the upper arm group (83.8 %), followed by the neck (69.8 %), forearm (53.2 %), chest (41.8 %), and other groups (34.2 %). Upper arm venipuncture with ultrasound guidance seems the most promising technique to prevent complications of central venous port implantation.
Manning, James E
2013-08-01
Aortic catheter-based resuscitation therapies are emerging with laboratory investigations showing benefit in models of trauma-related noncompressible torso hemorrhage and nontraumatic cardiac arrest. For these investigational aortic catheter-based therapies to reach their greatest potential clinical benefit, the ability to initiate them in the prehospital setting will be important. Feasibility of prehospital aortic catheterization without imaging capability supports this potential and is described in this report. A physician prehospital response system was created in cooperation with the local emergency medical services system to provide invasive hemodynamic monitoring during cardiac arrest. Physicians were dispatched to all known or suspected prehospital cardiac arrests covered by the emergency medical services system. Physicians responded with a specialized vascular catheterization pack and a monitor with invasive pressure monitoring capability. The physicians performed blind thoracic aortic and central venous catheterizations in cardiac arrest patients in the prehospital setting to measure coronary perfusion pressure, to optimize closed-chest cardiopulmonary resuscitation technique, and to administer intra-aortic epinephrine. During a 2-year period, 22 medical cardiac arrest patients underwent prehospital invasive hemodynamic monitoring to guide resuscitation. Most patients had both aortic and central venous catheters inserted. The combination of intra-aortic epinephrine and adjustments in closed-chest cardiopulmonary resuscitation technique resulted in improved coronary perfusion pressure. Return of spontaneous circulation with survival to hospital admission was achieved in 50% (11 of 22) of these patients. This report demonstrates the feasibility of successful blind aortic and central venous catheterizations in the prehospital environment and supports the potential feasibility of other emerging aortic catheter-based resuscitation therapies.
Fakih, Mohamad G; Heavens, Michelle; Ratcliffe, Carol J; Hendrich, Ann
2013-11-01
Hospitals can better focus their efforts to prevent health care-associated infections (HAIs) if they identify specific areas for improvement. We administered a 96-question survey to infection preventionists at 71 Ascension Health hospitals to evaluate opportunities for the prevention of catheter-associated urinary tract infection, central line-associated bloodstream infection, ventilator-associated pneumonia, and surgical site infection. Seventy-one (100%) infection preventionists completed the survey. The majority of hospitals had established policies for urinary catheter placement and maintenance (55/70, 78.6%), central venous catheter maintenance (68/71, 95.8%), and care for the mechanically ventilated patient (62/66, 93.9%). However, there was variation in health care worker practice and evaluation of competencies and outcomes. When addressing device need, 55 of 71 (77.5%) hospitals used a nurse-driven evaluation of urinary catheter need, 26 of 71 (36.6%) had a team evaluation for central venous catheters on transfer out of intensive care, and 53 of 57 (93%) assessed daily ventilator support for continued need. Only 19 of 71 (26.8%) hospitals had annual nursing competencies for urinary catheter placement and maintenance, 29 of 71 (40.8%) for nursing venous catheter maintenance, and 38 of 66 (57.6%) for appropriate health care worker surgical scrubbing. We suggest evaluating infection prevention policies and practices as a first step to improvement efforts. The next steps include implementing spread of evidence-based practices, with focus on competencies and feedback on performance. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.
McLeod, David
2009-01-01
The first definitive study of retinal vein occlusion complicated by infarction within the territory of one or more cilioretinal arteries was published in 1976. Many individual cases and further case series have been reported in the interim, but the nature of the interrelationship is still under debate. A review was undertaken of the relevant clinical and fundus fluorescein angiographic characteristics of this combined retinal vascular disorder together with the pathophysiological mechanisms currently presented in the literature to explain their association. Scientific publications up to 2008 were evaluated by one of the authors of the original report. There are broad similarities between publications in their descriptions of the clinical features, but significant differences of detail and interpretation are also evident. Most of the mechanisms so far proposed to account for cilioretinal infarction after central or hemisphere retinal vein occlusion do not withstand critical scrutiny. Two related hypotheses are expounded that appear to satisfactorily elucidate this interrelationship -- branch flow exclusion and branch flow diversion (otherwise termed "choroidal arterial steal"). In eyes with a cilioretinal supply, the probability that cilioretinal infarction will complicate retinal vein occlusion increases with increasing severity of venous obstruction and the more distally the cilioretinal artery arises from the posterior ciliary arterial tree. A distal branch point also facilitates observation of dye front reciprocation within the artery. Indicators of the degree of venous obstruction that may be necessary to instigate cilioretinal infarction include very prolonged dye transit times in the central retinal circulation, exaggerated venous cyanosis and tortuosity, perivenous cotton-wool sentinels, and macular perivenular whitening.
Haider, Clifton R.; Glockner, James F.; Stanson, Anthony W.; Riederer, Stephen J.
2009-01-01
Purpose: To prospectively evaluate the feasibility of performing high-spatial-resolution (1-mm isotropic) time-resolved three-dimensional (3D) contrast material–enhanced magnetic resonance (MR) angiography of the peripheral vasculature with Cartesian acquisition with projection-reconstruction–like sampling (CAPR) and eightfold accelerated two-dimensional (2D) sensitivity encoding (SENSE). Materials and Methods: All studies were approved by the institutional review board and were HIPAA compliant; written informed consent was obtained from all participants. There were 13 volunteers (mean age, 41.9; range, 27–53 years). The CAPR sequence was adapted to provide 1-mm isotropic spatial resolution and a 5-second frame time. Use of different receiver coil element sizes for those placed on the anterior-to-posterior versus left-to-right sides of the field of view reduced signal-to-noise ratio loss due to acceleration. Results from eight volunteers were rated independently by two radiologists according to prominence of artifact, arterial to venous separation, vessel sharpness, continuity of arterial signal intensity in major arteries (anterior and posterior tibial, peroneal), demarcation of origin of major arteries, and overall diagnostic image quality. MR angiographic results in two patients with peripheral vascular disease were compared with their results at computed tomographic angiography. Results: The sequence exhibited no image artifact adversely affecting diagnostic image quality. Temporal resolution was evaluated to be sufficient in all cases, even with known rapid arterial to venous transit. The vessels were graded to have excellent sharpness, continuity, and demarcation of the origins of the major arteries. Distal muscular branches and the communicating and perforating arteries were routinely seen. Excellent diagnostic quality rating was given for 15 (94%) of 16 evaluations. Conclusion: The feasibility of performing high-diagnostic-quality time-resolved 3D contrast-enhanced MR angiography of the peripheral vasculature by using CAPR and eightfold accelerated 2D SENSE has been demonstrated. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081744/-/DC1 PMID:19789238
Cryptococcus laurentii fungaemia in a cervical cancer patient.
Neves, Rejane Pereira; Lima Neto, Reginaldo Gonçalves de; Leite, Melyna Chaves; Silva, Vanessa Karina Alves da; Santos, Franz de Assis Graciano dos; Macêdo, Danielle Patrícia Cerqueira
2015-01-01
Infections caused by emerging Cryptococcus non-neoformans species are being reported with increasingly frequency. Here, we present a case of fungaemia by Cryptococcus laurentii in a woman receiving aggressive immunosuppressive therapy for cervical neoplasia. Three venous blood samples were aseptically collected on consecutive days and C. laurentii was isolated and identified through phenotypic and molecular methods. After central venous catheter removal and appropriate antifungal therapy, the patient showed significant improvement and blood culture became negative. Thus, patients following immunosuppressive therapies and using invasive medical devices are at risk of C. laurentii blood infections. Copyright © 2015 Elsevier Editora Ltda. All rights reserved.
Central venous catheter - flushing
... on a pair of sterile gloves. Remove the cap on the saline syringe and set the cap down on the paper towel. DO NOT let ... It is a good idea to change the caps at the end of your catheter (called the " ...
Patient Safety Learning Laboratory: Making Acute Care More Patient-Centered
2017-03-22
Central Line-Associated Bloodstream Infection (CLABSI); Venous Thromboembolism; Patient Fall; Catheter-Associated Infection; Severe Hypoglycemia; Opioid-Related Severe Adverse Drug Event; Hospital Acquired Pressure Ulcer; Adverse Drug Event; Severe Hospital Acquired Delerium; Rapid Response Related to Arrhythmia
Reversing Patterns of Control in Australia: Can Schools Be Self-Governing?
ERIC Educational Resources Information Center
Smart, Don
Historically, in sharp contrast with the United States, the Australian state systems of public education have always been extremely centralized and hierarchical in structure. While these highly centralized systems served the sparsely populated Australian states well during the early years of this century in providing universal free education and…
DE Simone, Roberto; Ranieri, Angelo; Bonavita, Vincenzo
2017-03-01
Two critical functions for the control of intracranial fluids dynamics are carried on the venous side of the perfusion circuit: the first is the avoidance of cortical veins collapse during the physiological increases of cerebrospinal fluid (CSF) pressure in which they are immersed. The second, is the generation of an abrupt venous pressure drop at the confluence of the cortical veins with the dural sinuses that is required to allow a CSF outflow rate balanced with its production. There is evidence that both of these effects are ensured by a Starling resistor mechanism (a fluid dynamic construct that governs the flow in collapsible tubes exposed to variable external pressure) acting at the confluence of cortical veins in the dural sinus. This implies that, in normal circumstances of perfusion balance, a certain degree of venous collapse physiologically occurs at the distal end of the cortical vein. This is passively modulated by the transmural pressure of the venous wall (i.e. the difference between internal blood pressure and external CSF pressure). The mechanism provides that the blood pressure of the cortical vein upstream the collapsed segment is dynamically maintained a few mmHg higher than the CSF pressure, so as to prevent their collapse during the large physiological fluctuations of the intracranial pressure. Moreover, the partial collapse of the vein confluence also generates a sharp pressure drop of the blood entering into the sinus. The CSF is drained in dural sinus through arachnoid villi proportionally to its pressure gradient with the sinus blood. The venous pressure drop between cortical veins and dural sinus is therefore needed to ensure that the CSF can leave the cranio-spinal space with the same speed with which it is produced, without having to reach a too high pressure, which would compress the cortical veins. Notably, the mechanism requires that the walls of the dural sinuses are rigid enough to avoid the collapse under the external cerebrospinal fluid pressure, and predicts that in the presence of excessively flexible dural sinuses, the system admits a second point of balance between cerebral fluid pressure and dural sinus pressure, at higher values. The second balance state is due to the triggering of a self-limiting venous collapse feedback loop between the CSF pressure, that compresses the sinus, and the subsequent increase of the dural sinus pressure, that further raises the intracranial pressure. The loop may stabilize only when the maximum stretching allowed by the venous wall is reached. Then, a new relatively stable and self-sustaining balance state is achieved, at the price of a higher CSF and dural sinus pressure values. We propose that this model is crucially involved in Idiopatic Intracranial Hypertension pathogenesis with and without papilledema, a condition that could be described as a pathological new balance state, relatively stable, between intracranial and dural venous pressure, at higher absolute values.
A Case of Neuro-Behcet's Disease Presenting with Central Neurogenic Hyperventilation.
Alkhachroum, Ayham M; Saeed, Saba; Kaur, Jaspreet; Shams, Tanzila; DeGeorgia, Michael A
2016-03-11
Behcet's disease is a chronic inflammatory disorder usually characterized by the triad of oral ulcers, genital ulcers, and uveitis. Central to the pathogenesis of Behcet's disease is an autoimmune vasculitis. Neurological involvement, so called "Neuro-Behcet's disease", occurs in 10-20% of patients, usually from a meningoencephalitis or venous thrombosis. We report the case of a 46-year-old patient with Neuro-Behcet's disease who presented with central neurogenic hyperventilation as a result of brainstem involvement from venulitis. To the best of our knowledge, central neurogenic hyperventilation has not previously been described in a patient with Neuro-Behcet's disease.
Juhl, Rebecca C; Roddy, Julianna V F; Wang, Tzu-Fei; Li, Junan; Elefritz, Jessica L
2018-02-09
Aminocaproic acid is frequently used in patients with hematologic malignancy that present with thrombocytopenia with or without hemorrhage. We conducted a retrospective study to evaluate the safety of aminocaproic acid in 109 patients with hematologic malignancies. Patients were included if aminocaproic acid had been administered for at least 24 hours for the prevention or treatment of thrombocytopenic hemorrhage. Our primary outcome was thromboembolic complications defined as arterial or venous thrombotic events objectively confirmed by imaging studies. Thromboembolic complications occurred in five patients (4.6%) and all were venous thromboses. Other than the underlying malignancy, these patients also had many concurrent risk factors including indwelling central venous catheters, which could have contributed to thromboses. In conclusion, in our population of patients with a variety of hematological malignancies, aminocaproic acid does not appear to be associated with a high incidence of thromboembolic complications.
Inspiratory Resistance as a Potential Treatment for Orthostatic Intolerance and Hemorrhagic Shock
2005-04-01
central blood volume by forcing the thoracic muscles to develop increased negative pressure , thus drawing venous blood from extrathoracic cavi- ties...cardiac baroreflex sensitivity associated with re- ductions of central blood volume during lower body negative pressure (LBNP) are reversed with...9:621–26. 8. Chapleau MW, Abboud FM. Contrasting effects of static and pulsatile pressure on carotid baroreceptor activity in dogs. Circ Res 1987; 61
AltitudeOmics: The Basic Biology of Human Acclimatization to High Altitude. Addendum
2014-09-01
first subject had completed the arterial/ venous catheterization and cognitive testing portion of the protocol. Then the second subject began the protocol...attenuates, but does not eliminate, the exacerbation of central fatigue associated with exercise in severe acute hypoxia. c. Fan JL, Subudhi AW, Evero...that best characterize acclimatization [1]. Most would agree that improving arterial oxygenation and exercise performance are central tenets of PLOS
Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi
2013-06-01
Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.
... the back of the eye Macular degeneration - a disease that destroys sharp, central vision Diabetic eye problems ... defense is to have regular checkups, because eye diseases do not always have symptoms. Early detection and ...
Microsurgical anatomy of the central lobe.
Frigeri, Thomas; Paglioli, Eliseu; de Oliveira, Evandro; Rhoton, Albert L
2015-03-01
The central lobe consists of the pre- and postcentral gyri on the lateral surface and the paracentral lobule on the medial surface and corresponds to the sensorimotor cortex. The objective of the present study was to define the neural features, craniometric relationships, arterial supply, and venous drainage of the central lobe. Cadaveric hemispheres dissected using microsurgical techniques provided the material for this study. The coronal suture is closer to the precentral gyrus and central sulcus at its lower rather than at its upper end, but they are closest at a point near where the superior temporal line crosses the coronal suture. The arterial supply of the lower two-thirds of the lateral surface of the central lobe was from the central, precentral, and anterior parietal branches that arose predominantly from the superior trunk of the middle cerebral artery. The medial surface and the superior third of the lateral surface were supplied by the posterior interior frontal, paracentral, and superior parietal branches of the pericallosal and callosomarginal arteries. The venous drainage of the superior two-thirds of the lateral surface and the central lobe on the medial surface was predominantly through the superior sagittal sinus, and the inferior third of the lateral surface was predominantly through the superficial sylvian veins to the sphenoparietal sinus or the vein of Labbé to the transverse sinus. The pre- and postcentral gyri and paracentral lobule have a morphological and functional anatomy that differentiates them from the remainder of their respective lobes and are considered by many as a single lobe. An understanding of the anatomical relationships of the central lobe can be useful in preoperative planning and in establishing reliable intraoperative landmarks.
Karakitsos, Dimitrios; Labropoulos, Nicolaos; De Groot, Eric; Patrianakos, Alexandros P; Kouraklis, Gregorios; Poularas, John; Samonis, George; Tsoutsos, Dimosthenis A; Konstadoulakis, Manousos M; Karabinis, Andreas
2006-01-01
Introduction Central venous cannulation is crucial in the management of the critical care patient. This study was designed to evaluate whether real-time ultrasound-guided cannulation of the internal jugular vein is superior to the standard landmark method. Methods In this randomised study, 450 critical care patients who underwent real-time ultrasound-guided cannulation of the internal jugular vein were prospectively compared with 450 critical care patients in whom the landmark technique was used. Randomisation was performed by means of a computer-generated random-numbers table, and patients were stratified with regard to age, gender, and body mass index. Results There were no significant differences in gender, age, body mass index, or side of cannulation (left or right) or in the presence of risk factors for difficult venous cannulation such as prior catheterisation, limited sites for access attempts, previous difficulties during catheterisation, previous mechanical complication, known vascular abnormality, untreated coagulopathy, skeletal deformity, and cannulation during cardiac arrest between the two groups of patients. Furthermore, the physicians who performed the procedures had comparable experience in the placement of central venous catheters (p = non-significant). Cannulation of the internal jugular vein was achieved in all patients by using ultrasound and in 425 of the patients (94.4%) by using the landmark technique (p < 0.001). Average access time (skin to vein) and number of attempts were significantly reduced in the ultrasound group of patients compared with the landmark group (p < 0.001). In the landmark group, puncture of the carotid artery occurred in 10.6% of patients, haematoma in 8.4%, haemothorax in 1.7%, pneumothorax in 2.4%, and central venous catheter-associated blood stream infection in 16%, which were all significantly increased compared with the ultrasound group (p < 0.001). Conclusion The present data suggest that ultrasound-guided catheterisation of the internal jugular vein in critical care patients is superior to the landmark technique and therefore should be the method of choice in these patients. PMID:17112371
Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J.A.; Dandorf, Stewart J.; Dunleavy, James; Viscusi, Rebecca; Amini, Richard
2016-01-01
Introduction Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. Methods This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Results Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). Conclusion The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills. PMID:27330672
Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard
2016-05-01
Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills.
Increased rate of venous thrombosis may be associated with inpatient dihydroergotamine treatment.
Tso, Amy R; Patniyot, Irene R; Gelfand, Amy A; Goadsby, Peter J
2017-07-18
To review whether the incidence of catheter-associated venous thromboses was higher in patients receiving IV dihydroergotamine compared to lidocaine. We retrospectively reviewed all admissions at the University of California, San Francisco Headache Center from February 25, 2008, through October 31, 2014, for age, sex, diagnosis, aura, treatment dose, type of IV line used, days with line, superficial (SVT) or deep venous thrombosis (DVT), and pulmonary embolism (PE). A peripherally inserted central catheter (PICC) or midline catheter was placed in 315 of 589 (53%) admissions. Mean age was 38 years with a range of 6 to 79 years; 121 patients (21%) were ≤18 years old. Seventy-four percent (433 of 589) of patients were female. Of 263 dihydroergotamine admissions using a PICC or midline catheter, 19 (7.2%) had either an SVT or DVT or a PE; 2 patients were diagnosed with both DVT and PE. Of 52 lidocaine admissions using a PICC or midline catheter, none had a thrombotic event ( p = 0.05, Fisher exact test). Age, sex, aura, total dihydroergotamine dose, and number of days with line were not significant predictors of venous thrombosis. IV dihydroergotamine treatment may be associated with an increased risk of catheter-associated venous thrombosis. A low threshold for diagnostic ultrasound investigation is appropriate because anticoagulation therapy was frequently required. © 2017 American Academy of Neurology.
2010-01-01
Background The incidence of venous ulceration is rising with the increasing age of the general population. Venous ulceration represents the most prevalent form of difficult to heal wounds and these problematic wounds require a significant amount of health care resources for treatment. Based on current knowledge multi-layer high compression system is described as the gold standard for treating venous ulcers. However, to date, despite our advances in venous ulcer therapy, no convincing low cost compression therapy studies have been conducted and there are no clear differences in the effectiveness of different types of high compression. Methods/Design The trial is designed as a pilot multicentre open label parallel group randomised trial. Male and female participants aged greater than 18 years with a venous ulcer confirmed by clinical assessment will be randomised to either the intervention compression bandage which consists of graduated lengths of 3 layers of elastic tubular compression bandage or to the short stretch inelastic compression bandage (control). The primary objective is to assess the percentage wound reduction from baseline compared to week 12 following randomisation. Randomisation will be allocated via a web based central independent randomisation service (nQuery v7) and stratified by study centre and wound size ≤ 10 cm2 or >10 cm2. Neither participants nor study staff will be blinded to treatment. Outcome assessments will be undertaken by an assessor who is blinded to the randomisation process. Discussion The aim of this study is to evaluate the efficacy and safety of two compression bandages; graduated three layer straight tubular bandaging (3L) when compared to standard short stretch (SS) compression bandaging in healing venous ulcers in patients with chronic venous ulceration. The trial investigates the differences in clinical outcomes of two currently accepted ways of treating people with venous ulcers. This study will help answer the question whether the 3L compression system or the SS compression system is associated with better outcomes. Trial Registration ACTRN12608000599370 PMID:20214822
NASA Astrophysics Data System (ADS)
Petrov, Andrey; Prough, Donald S.; Petrov, Irene Y.; Petrov, Yuriy; Deyo, Donald J.; Henkel, Sheryl N.; Seeton, Roger; Esenaliev, Rinat O.
2013-03-01
Monitoring of cerebral venous oxygenation is useful to facilitate management of patients with severe or moderate traumatic brain injury (TBI). Prompt recognition of low cerebral venous oxygenation is a key to avoiding secondary brain injury associated with brain hypoxia. In specialized clinical research centers, jugular venous bulb catheters have been used for cerebral venous oxygenation monitoring and have demonstrated that oxygen saturation < 50% (normal range is 55-75%) correlates with poor clinical outcome. We developed an optoacoustic technique for noninvasive monitoring of cerebral venous oxygenation. Recently, we designed and built a novel, medical grade optoacoustic system operating in the near-infrared spectral range for continuous, real-time oxygenation monitoring in the superior sagittal sinus (SSS), a large central cerebral vein. In this work, we designed and built a novel SSS optoacoustic probe and developed a new algorithm for SSS oxygenation measurement. The SSS signals were measured in healthy volunteers during voluntary hyperventilation, which induced changes in SSS oxygenation. Simultaneously, we measured exhaled carbon dioxide concentration (EtCO2) using capnography. Good temporal correlation between decreases in optoacoustically measured SSS oxygenation and decreases in EtCO2 was obtained. Decreases in EtCO2 from normal values (35-45 mmHg) to 20-25 mmHg resulted in SSS oxygenation decreases by 3-10%. Intersubject variability of the responses may relate to nonspecific brain activation associated with voluntary hyperventilation. The obtained data demonstrate the capability of the optoacoustic system to detect in real time minor changes in the SSS blood oxygenation.
1999-10-08
A dark, smooth, relatively uncratered area on Mercury was photographed two hours after NASA Mariner 10 flew by the planet. The prominent, sharp crater with a central peak is 30 kilometers 19 miles across.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques
2012-01-01
The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use.
Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques
2012-01-01
The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use. PMID:23166455
Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio
2017-03-01
To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.
Double external jugular vein and other rare venous variations of the head and neck.
Shenoy, Varsha; Saraswathi, Perumal; Raghunath, Gunapriya; Karthik, Jayakumar Sai
2012-12-01
Superficial veins of the head and neck are utilised for central venous cannulation, oral reconstruction and parenteral nutrition in debilitated patients. Clinical and sonological examinations of these veins may provide clues toward underlying cardiac pathology. Hence, although variations in these vessels are common, a sound knowledge of such variations becomes clinically important to surgeons, radiologists and interventional anaesthetists. We report a rare case of a left-sided double external jugular vein where the common facial vein continued as the second external jugular vein, and where there was a communicating channel between the internal jugular vein on the same side and the anterior jugular vein.
Palmer, Kenneth; Ridgway, Tim; Al-Rawi, Omar; Johnson, Ian; Poullis, Michael
2011-09-01
Some patients have short intensive care stay periods and little or no organ dysfunction after cardiac surgery and others do not despite seemingly faultless surgery, perfusion, and anesthesia. These "unknown" reasons for death and morbidity usually relate to organ ischemia and inflammation, but are obviously mutlifactorial. A Lissajous figure is a technique in electrical engineering to compare two different electrical signals. We utilize this basic concept in a very simple manner to potentially identify why some of these unknown deaths or morbidities occur. Utilizing an electronic perfusion database, we retrospectively analyzed 43 patients undergoing aortic surgery with regard to central venous saturations during cooling and rewarming. Isolated aortic valve replacement patients were excluded. Central venous saturation, time, and temperature were plotted to create a Lissajous figure for the whole operation, and during cooling and rewarming separately. Temperature and saturations were analyzed every 20 seconds. Perfusion related variables were registered and uploaded to www.perfsort.net. Lissajous figures during cooling add little to patient care due to their similarity. Isolated rewarming revealed startling differences. It is immediately visually obvious who had short and long periods of tissue ischemia and reperfusion during rewarming in a seemingly uneventful operation. The periods of ischemia can be semi quantified into: none, mild, moderate, and severe. Creation of simple Lissajous figures during rewarming for bypass runs may be an additional helpful tool in root cause analysis of patient death/morbidity when surgery, perfusion, and anesthesia seemed faultless. Low central venous saturations at hypothermic temperatures mean significant metabolic activity, indicating tissue ischemia is occurring. Further work is needed to correlate this concept to outcomes.
Body surface infrared thermometry in patients with central venous cateter-related infections
Silvah, José Henrique; de Lima, Cristiane Maria Mártires; de Unamuno, Maria do Rosário Del Lama; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile, Anibal; da Cunha, Selma Freire Carvalho; Marchini, Julio Sergio
2015-01-01
Objective To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Methods Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. Results A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus -0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus -0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus -0.22 - -0.10ºC; p<0.01). Conclusion Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area. PMID:26466058
Qian, Geng; Fu, Zhenhong; Guo, Jun; Cao, Feng; Chen, Yundai
2016-01-11
This study aimed to explore the hemodynamic index-guided hydration method for patients with congestive heart failure (CHF) and chronic kidney disease (CKD) to reduce the risk of contrast-induced nephropathy (CIN) and at the same time to avoid the acute heart failure. Patients at moderate or high risk for CIN should receive sufficient hydration before contrast application. This prospective, randomized, double-blind, comparative clinical trial enrolled 264 consecutive patients with CKD and CHF undergoing coronary procedures. These patients were randomly assigned to either central venous pressure (CVP)-guided hydration group (n = 132) or the standard hydration group (n = 132). In the CVP-guided group, the hydration infusion rate was dynamically adjusted according to CVP level every hour. CIN was defined as an absolute increase in serum creatinine (SCr) >0.5 mg/dl (44.2 μmol/l) or a relative increase >25% compared with baseline SCr. Baseline characteristics were well-matched between the 2 groups. The total mean volume of isotonic saline administered in the CVP-guided hydration group was significantly higher than the control group (1,827 ± 497 ml vs. 1,202 ± 247 ml; p < 0.001). CIN occurred less frequently in CVP-guided hydration group than the control group (15.9% vs. 29.5%; p = 0.006). The incidences of acute heart failure during the hydration did not differ between the 2 groups (3.8% vs. 3.0%; p = 0.500). CVP-guided fluid administration can safely and effectively reduce the risk of CIN in patients with CKD and CHF. (Central Venous Pressure Guided Hydration Prevention for Contrast-Induced Nephropathy; NCT02405377). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Lin, Chun-Yu; Chen, Tun-Chieh; Lu, Po-Liang; Chen, Hui-Juan; Bojang, Kebba S; Chen, Yen-Hsu
2014-10-01
The cornerstone of emergency management of severe sepsis and septic shock is early (within 6 hours) goal-directed therapy, including maintenance of central venous pressure (CVP) at 8-12 mmHg. It is unclear whether there is a difference in initial (baseline) CVP between septic patients who are referred from the community and those who come from long-term care facilities (LTCFs) in Taiwan. We designed this study to investigate the difference in hemodynamic parameters between these two groups. Every patient with severe sepsis or septic shock who had a central venous catheter inserted via the internal jugular or subclavian vein at Kaohsiung Medical University Hospital between April 2007 and October 2007 was enrolled. CVP was measured immediately at the emergency department. Patient demographics, including residence, were retrospectively recorded and analyzed. There were 166 evaluable patients; 125 (75.3%) came from the community and 41 (24.7%) from LTCFs. There were no significant differences in age, sex, initial body temperature, heart rate, blood pressure, or leukocyte count between the two groups. However, patients who were referred from LTCFs had a significantly lower initial CVP than those from the community (5.0 ± 4.5 mmHg vs. 7.0 ± 4.8 mmHg, p = 0.023). The difference was more significant between mechanically ventilated patients from LTCFs and those from the community (5.0 ± 3.0 mmHg vs. 8.1 ± 5.6 mmHg, p = 0.006). Severely septic patients referred from LTCFs may require more aggressive fluid resuscitation within the first 6 hours of the diagnostic criteria met at the emergency department to achieve the CVP target of early goal-directed therapy. Copyright © 2013. Published by Elsevier B.V.
Mema, Briseida; Harris, Ilene
2016-01-01
PHENOMENON: Ultrasound-guided central venous line insertion is currently the standard of care. Randomized controlled trials and systematic reviews show that simulation is superior to apprenticeship training. The purpose of this study is to explore, from the perspectives of participants in a simulation-training program, the factors that help or hinder the transfer of skills from simulation to practice. Purposeful sampling was used to select and study the experience and perspective of novice fellows after they had completed simulation training and then performed ultrasound-guided central venous line in practice. Seven novice pediatric intensive care unit fellows and six supervising faculty in a university-affiliated academic center in a large urban city were recruited between September 2012 and January 2013. We conducted a qualitative study using semistructured interviews as our data source, employing a constructivist, grounded theory methodology. Both curricular and real-life factors influence the transfer of skills from simulation to practice and the overall performance of trainees. Clear instructions, the opportunity to practice to mastery, one-on-one observation with feedback, supervision, and further real-life experiences were perceived as factors that facilitated the transfer of skills. Concern for patient welfare, live trouble shooting, complexity of the intensive care unit environment, and the procedure itself were perceived as real-life factors that hindered the transfer of skills. Insights: As more studies confirm the superiority of simulation training versus apprenticeship training for initial student learning, the faculty should gain insight into factors that facilitate and hinder the transfer of skills from simulation to bedside settings and impact learners' performances. As simulation further augments clinical learning, efforts should be made to modify the curricular and bedside factors that facilitate transfer of skills from simulation to practice settings.
Paksoy, Yahya; Gormus, Niyazi; Tercan, Mehmet Akif
2004-01-01
Arteriovenous (AV) fistulas are crucial in patients requiring long-term hemodialysis (HD). Dysfunctions of these fistulas are the most common causes of recurrent hospitalizations. This study aimed to evaluate the feasibility, safety and usefulness of contrast-enhanced magnetic resonance angiography (CE-MRA) in the evaluation of HD fistulas complications, and the condition of the central veins before HD access. This study comprised 30 consecutive patients (15 females, 15 males; age range 25-66 yrs, mean +/- SD 51.2 +/- 9.9 yrs). Of 30 patients, 26 had native AV fistulas and the remaining four patients, who had a history of previous subclavian vein catheterization, were candidates for HD fistulas. Nine patients had a radiocephalic fistula, 15 had a brachiobasilic fistula, one had a saphenous vein graft, and one had brachiobasilic vein transposition. To observe the fistula complications in these cases, three-dimensional (3-D) CE-MRA using gadolinium was performed. The results were considered normal in three patients (10%), who were candidates for AV fistula construction; one patient had central vein occlusion due to previous catheterization. Thirteen patients (43.3%) had venous stenosis or occlusion; three of them (10%) had low CE arteries distal to fistula region, leading to ischemic complications, and six (20%) had stenosis at the fistula region. Seven patients (23.3%) had venous pseudoaneurysms, whereas two of them had both pseudoaneurysms and fistula region stenosis, and one had both venous stenosis and pseudoaneurysm. There were no adverse or allergic-like reactions or heat and taste sensations observed in our series. 3-D CE-MRA is a useful, safe and a practical imaging modality in complicated fistula diagnosis with fewer complications and side-effects in comparison to fistulography.
Worth, Leon J; Seymour, John F; Slavin, Monica A
2009-07-01
Central venous catheter (CVC)-related bloodstream infection (CR-BSI) is a significant complication in hematology patients. A range of CVC devices may be used, and risks for the development of complications are not uniform. The objectives of this study were to determine the natural history and rate of CVC-related complications and risk factors for CR-BSI and to compare device-specific complications in a hematology population. An observational cohort of patients with hematologic malignancy was prospectively studied following CVC insertion. Participants were reviewed until a CVC-related complication necessitated device removal, completion of therapy, death, or defined end-of-study date. The National Nosocomial Infection Surveillance definition for CR-BSI was used. Overall and device-specific rates of infective and noninfective complications were calculated and potential risk factors were captured. One hundred six CVCs (75 peripherally inserted central venous catheters [PICCs], 31 nontunneled CVCs) were evaluated in 66 patients, over 2,399 CVC days. Thrombosis occurred in 16 cases (15.1%), exit-site infection in two (1.9%), and CR-BSI in 18 (7.5 per 1,000 CVC days). No significant differences were found when complication rates in PICC and nontunneled devices were compared. An underlying diagnosis of acute myeloid leukemia was negatively associated with CR-BSI (odds ratio (OR) 0.14, p = 0.046), and a previous diagnosis of fungal infection was associated with infection (OR 22.82, p = 0.031). CR-BSI rates in our hematology population are comparable to prior reports. A low rate of exit-site infection and high proportion of thrombotic complications were observed. No significant differences in thrombotic or infective complications were evident when PICC and nontunneled devices were compared. PICC devices are a practical and safe option for management of hematology patients.
Kroencke, T J; Taupitz, M; Arnold, R; Fritsche, L; Hamm, B
2001-11-01
To determine the usefulness of high-resolution three-dimensional (3D) gadolinium-enhanced magnetic resonance venography (MRV) in the evaluation of central venous thrombo-occlusive disease of the chest. Prospective study. University hospital. Sixteen consecutive patients with clinically suspected thrombosis of the superior vena cava, subclavian, brachiocephalic/innominate, internal jugular, or axillary veins. Thirteen patients had a neoplasm, two patients had a connective tissue disease, and one patient had a history of strenuous exercise. Twelve of 16 patients had prior central venous catheter placement. MRI was correlated with color-coded duplex sonography (CCDS) in 7 of 16 patients, digital subtraction angiography (DSA) in 3 of 16 patients, and CT in 2 of 16 patients. Contrast-enhanced MRV was performed in a total of 20 examinations. A 3D data set (gradient echo; time to repeat, 4.6 ms; time to echo, 1.8 ms; flip angle, 30 degrees; time of acquisition, 23 s; 512 matrix/64 partitions; slice thickness, 1.5 mm) was acquired in the arterial and venous phase. Overall image quality was assessed on a 5-point scale. The presence, site, and extent of thrombus, as well as presence of an intravascular device, were determined. Overall image quality was rated very good (1 point) in 7 of 16 cases (44%) and good (2 points) in 9 of 16 cases (56%). Thrombus was detected in 16 of 16 patients, and complete extent of disease could be determined in 15 of 16 patients (94%). MRV did not miss any finding obtained by CCDS, DSA, or CT, and provided additional information in 6 of 16 examinations (38%). Contrast-enhanced MRV is a fast and reliable noninvasive procedure with excellent results regarding detection and determination of the extent of thrombo-occlusive disease of the chest veins.
Luther, Megan K; Mermel, Leonard A; LaPlante, Kerry L
2016-03-01
Results of a study of the activity of antibiotic lock solutions of vancomycin and telavancin against biofilm-forming strains of Staphylococcus epidermidis, Enterococcus faecalis, and Staphylococcus aureus are reported. An established in vitro central venous catheter model was used to evaluate lock solutions containing vancomycin (5 mg/mL) or telavancin (5 mg/mL), with and without preservative-containing heparin sodium (with 0.45% benzyl alcohol) 2500 units/mL, heparin, and 0.9% sodium chloride solution. Lock solutions were introduced after 24-hour bacterial growth in catheters incubated at 35 °C. After 72 hours of exposure to the lock solutions, catheters were drained, flushed, and cut into segments for quantification of colony-forming units. Against S. epidermidis, vancomycin and telavancin (with or without heparin) had similar activity. Against E. faecalis, vancomycin alone was more active than telavancin alone (p < 0.01). Against S. aureus, vancomycin plus heparin had activity similar to that of vancomycin alone; both lock agents had greater activity than telavancin (p < 0.02). The addition of heparin was associated with reduced activity of the vancomycin lock solution against S. epidermidis and E. faecalis (p < 0.01). Telavancin activity was not significantly changed with the addition of heparin. In a central venous catheter model, vancomycin and telavancin activity was similar in reducing biofilm-producing S. epidermidis. However, vancomycin was more active than telavancin against E. faecalis and S. aureus. None of the tested agents eradicated biofilm-forming strains. The addition of preservative-containing heparin sodium 2500 units/mL to vancomycin was associated with reduced activity against S. epidermidis and E. faecalis. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Body surface infrared thermometry in patients with central venous cateter-related infections.
Silvah, José Henrique; Lima, Cristiane Maria Mártires de; Unamuno, Maria do Rosário Del Lama de; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile-Filho, Anibal; Cunha, Selma Freire Carvalho da; Marchini, Julio Sergio
2015-01-01
To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus-0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus-0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus-0.22 - -0.10ºC; p<0.01). Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.
Lee, Guk Jin; Hong, Sook Hee; Roh, Sang Young; Park, Sa Rah; Lee, Myung Ah; Chun, Hoo Geun; Hong, Young Seon; Kang, Jin Hyoung; Kim, Sang Il; Kim, Youn Jeong; Chun, Ho Jong; Oh, Jung Suk
2014-07-01
To date, the risk factors for central venous port-related bloodstream infection (CVPBSI) in solid cancer patients have not been fully elucidated. We conducted this study in order to determine the risk factors for CVP-BSI in patients with solid cancer. A total of 1,642 patients with solid cancer received an implantable central venous port for delivery of chemotherapy between October 2008 and December 2011 in a single center. CVP-BSI was diagnosed in 66 patients (4%). We selected a control group of 130 patients, who were individually matched with respect to age, sex, and catheter insertion time. CVP-BSI occurred most frequently between September and November (37.9%). The most common pathogen was gram-positive cocci (n=35, 53.0%), followed by fungus (n=14, 21.2%). Multivariate analysis identified monthly catheter-stay as a risk factor for CVP-BSI (p=0.000), however, its risk was lower in primary gastrointestinal cancer than in other cancer (p=0.002). Initial metastatic disease and long catheter-stay were statistically significant factors affecting catheter life span (p=0.005 and p=0.000). Results of multivariate analysis showed that recent transfusion was a risk factor for mortality in patients with CVP-BSI (p=0.047). In analysis of the results with respect to risk factors, prolonged catheter-stay should be avoided as much as possible. It is necessary to be cautious of CVP-BSI in metastatic solid cancer, especially non-gastrointestinal cancer. In addition, avoidance of unnecessary transfusion is essential in order to reduce the mortality of CVP-BSI. Finally, considering the fact that confounding factors may have affected the results, conduct of a well-designed prospective controlled study is warranted.
Richter, Robert P; Law, Mark A; Borasino, Santiago; Surd, Jessica A; Alten, Jeffrey A
2016-12-01
To describe a novel real-time ultrasound (US)-guided distal superficial femoral vein (DSFV) cannulation technique for insertion of peripherally inserted central catheters (PICC) in critically ill infants with congenital heart disease. Descriptive retrospective cohort study SETTING: Pediatric cardiac intensive care unit in a pediatric tertiary hospital PATIENTS: First 28 critically ill infants that received DSFV PICCs via this new technique. Thirty-seven US-guided DSFV PICCs were attempted on 31 infants from September 2012 to November 2014; 34 PICCs were placed in 28 patients (success rate 92%). Twenty-six of 28 patients underwent cardiac surgery. Median (IQR) age at time of PICC placement 39 days (13, 151); weight 3.4 kg (3.2, 5.3). 25/34 PICCs were placed in patients with STAT 4 or 5 category. Median PICC duration 16 days (11, 29); maximum duration 123 days. Ten infants (36%) had DSFV PICCs placed as the primary central venous access in perioperative period. Ten of 28 patients underwent cardiac catheterization while DSFV PICC was in place, four of which were performed through ipsilateral common femoral vein. Two patients had femoral arterial lines placed in the ipsilateral femoral artery while DSFV PICC was in place. There were no reported inadvertent arterial punctures. The PICC-associated infection rate was 4.6 per 1000 line days. Four of 34 DSFV PICCs (11.8%) were associated with deep venous thrombosis. DSFV is a novel venous access site for PICC placement with high success rate and sufficient longevity and flexibility for critically ill infants with cardiac disease. More experience and larger studies are needed to confirm its potential advantages. © 2016 Wiley Periodicals, Inc.
Voldman, Alexander; Durbin, Breanna; Nguyen, John; Ellis, Brian; Leys, Monique
2017-03-10
To report a complicated case of fulminant idiopathic intracranial hypertension and concomitant venous stasis retinopathy leading to postpapilledema optic atrophy. Case report. A 34-year-old morbidly obese woman with a history of idiopathic intracranial hypertension (IIH) presented with a 1-month history of bilateral vision loss, diplopia, and left eye pain after being lost to follow-up for 6 years. Fundus examination revealed florid papilledema with venous tortuosity bilaterally. Brain and orbit magnetic resonance imaging showed bilateral globe flattening, intraocular optic nerve swelling in both eyes, and no abnormality on magnetic resonance venography. After additional workup including lumbar puncture with an opening pressure of 55 cm H2O, a diagnosis of IIH was confirmed. Medical treatment with oral carbonic anhydrase inhibitors was initiated, followed by same-day bilateral optic nerve sheath decompression and ventriculoperitoneal shunt placement the following week. Fundus examination 2 months later revealed a persistent blood and thunder fundus suggestive of bilateral central retinal vein occlusions. Over the course of 6 months, both eyes displayed postpapilledema optic atrophy with light perception and hand motion vision in the right and left eyes, respectively. On Goldmann perimetry, the patient had vague limited isolated responses in both eyes to the largest target. Fulminant IIH can present with profoundly blinding complications recalcitrant to aggressive medical and surgical intervention. Central retinal vein occlusion is an uncommon blinding complication of IIH.
Litigation related to anaesthesia: an analysis of claims against the NHS in England 1995-2007.
Cook, T M; Bland, L; Mihai, R; Scott, S
2009-07-01
The distribution of medico-legal claims in English anaesthetic practice is unreported. We studied National Health Service Litigation Authority claims related to anaesthesia since 1995. All claims were reviewed by three clinicians and variously categorised, including by type of incident, claimed outcome and cost. Anaesthesia-related claims account for 2.5% of all claims and 2.4% of the value of all claims. Of 841 relevant claims 366 (44%) were related to regional anaesthesia, 245 (29%) obstetric anaesthesia, 164 (20%) inadequate anaesthesia, 95 (11%) dental damage, 71 (8%) airway (excluding dental damage), 63 (7%) drug related (excluding allergy), 31 (4%) drug allergy related, 31 (4%) positioning, 29 (3%) respiratory, 26 (3%) consent, 21 (2%) central venous cannulation and 18 (2%) peripheral venous cannulation. Defining which cases are, from a medico-legal viewpoint, 'high risk' is uncertain, but the clinical categories with the largest number of claims were regional anaesthesia, obstetric anaesthesia, inadequate anaesthesia, dental damage and airway, those with the highest overall cost were regional anaesthesia, obstetric anaesthesia, and airway and those with the highest mean cost per closed claim were respiratory, central venous cannulation and drug error excluding allergy. The data currently available have limitations but offer useful information. A closed claims analysis similar to that in the USA would improve the clinical usefulness of analysis.
Horberry, Tim; Teng, Yi-Chun; Ward, James; Patil, Vishal; Clarkson, P John
2014-01-01
Central Venous Catheterisation (CVC) has occasionally been associated with cases of retained guidewires in patients after surgery. In theory, this is a completely avoidable complication; however, as with any human procedure, operator error leading to guidewires being occasionally retained cannot be fully eliminated. The work described here investigated the issue in an attempt to better understand it both from an operator and a systems perspective, and to ultimately recommend appropriate safe design solutions that reduce guidewire retention errors. Nine distinct methods were used: observations of the procedure, a literature review, interviewing CVC end-users, task analysis construction, CVC procedural audits, two human reliability assessments, usability heuristics and a comprehensive solution survey with CVC end-users. The three solutions that operators rated most highly, in terms of both practicality and effectiveness, were: making trainees better aware of the potential guidewire complications and strongly emphasising guidewire removal in CVC training, actively checking that the guidewire is present in the waste tray for disposal, and standardising purchase of central line sets so that differences that may affect chances of guidewire loss is minimised. Further work to eliminate/engineer out the possibility of guidewires being retained is proposed.
Kutty, Shelby; Xie, Feng; Gao, Shunji; Drvol, Lucas K; Lof, John; Fletcher, Scott E; Radio, Stanley J; Danford, David A; Hammel, James M; Porter, Thomas R
2010-01-01
Central venous and arterial catheters are a major source of thrombo-embolic disease in children. We hypothesized that guided high mechanical index (MI) impulses from diagnostic three-dimensional (3D) ultrasound during an intravenous microbubble infusion could dissolve these thrombi. An in vitro system simulating intra-catheter thrombi was created and then treated with guided high MI impulses from 3D ultrasound, utilizing low MI microbubble sensitive imaging pulse sequence schemes to detect the microbubbles (Perflutren Lipid Microsphere, Definity®, Lantheus). Ten aged thrombi over 24 hours old were tested using 3D ultrasound coupled with a continuous diluted microbubble infusion (Group A), and ten with 3D ultrasound alone (Group B). Mean thrombus age was 28.6 hours (range 26.6–30.3). Groups A exhibited a 55 ± 19 % reduction in venous thrombus size, compared to 31±10 % for Group B (p=0.008). Feasibility testing was performed in 4 pigs, establishing a model to further investigate the efficacy. Sonothrombolysis of aged intra-catheter venous thrombi can be achieved with commercially available microbubbles and guided high MI ultrasound from a diagnostic 3D transducer. PMID:20696549
Genetics Home Reference: Wagner syndrome
... which the part of the retina responsible for sharp central vision is out of place. Additionally, the ... Brouwer AP, van Nouhuys CE, Boon CJ, Perveen R, Zegers HA, Wittebol-Post D, van den Biesen ...
SvO2 Trigger in Transfusion Strategy After Cardiac Surgery
2018-03-27
Undergoing Nonemergent Cardiac Surgery; Central Venous Catheter on the Superior Vena Cava (to Perform ScVO2 Measure); Anemia (<9g/dL) Requiring Blood Transfusion; Hemodynamic and Respiratory Stability; Bleeding Graded as Insignificant, Mild, Moderate of Universal Definition of Perioperative Bleeding
Prospective comparison of two management strategies of central venous catheters in burn patients.
Kealey, G P; Chang, P; Heinle, J; Rosenquist, M D; Lewis, R W
1995-03-01
Central venous catheters (CVCs) are associated with sepsis in burn patients. This study was undertaken to compare two strategies of CVC management in patients with major burn injuries. Forty-two burn patients with major burn injuries were randomly assigned to undergo site change every 48 hours of the CVC or to undergo wire guide exchange of the CVC every 48 hours at the same site. Catheter insertion site, distance from the burn wound, cultures of catheter tips, and blood cultures were obtained from all patients in a prospective manner. There was no difference in the incidence of CVC sepsis between the two groups studied. CVCs inserted less than 5 cm from the burn wound developed bacterial contamination at an earlier time than CVCs inserted more than 5 cm from the burn wound. There was no advantage to changing the CVC insertion site every 48 hours. Changing the CVC using the wire guide technique did not prevent, nor predict, CVC bacterial contamination.
Gunduz, Yasemin; Vatan, Mehmet Bulent; Osken, Altug; Cakar, Mehmet Akif
2012-01-01
Central venous catheterisation allows delivery of medications, intravenous fluids, parenteral nutrition, haemodialysis and monitoring of haemodynamic variables. Various complications may occur during and after the procedure. However, the complete guidewire retention has rarely been reported. In this report, we have presented a complete guidewire retention as a result of inadvertent catheter insertion. After 17 months of the first operation performed upon the diagnosis of Fournier's gangrene, the patient was admitted to the cardiology polyclinic with a recurrent chest pain. Echocardiography showed a wire-shaped foreign body within the right part of the heart, and a fluoroscopic examination showed a guidewire reaching from the superior vena cava to the right external iliac vein. In retrospect, the wire was already visible on the postoperative chest x-rays and CT taken while the patient was still in intensive care unit, but its presence was overlooked at that time. The guidewire was retrieved completely during a surgery. PMID:23166171
Managing central venous obstruction in cystic fibrosis recipients--lung transplant considerations.
Otani, Shinji; Westall, Glen P; Levvey, Bronwyn J; Marasco, Silvana; Lyon, Stuart; Snell, Gregory I
2015-03-01
The superior vena cava (SVC) syndrome in cystic fibrosis (CF) patients is rare, but presents unique challenges in the peri-transplant period. We reviewed our experience of SVC syndrome in CF recipients undergoing lung transplantation. This is a retrospective case series from a single center chart-review. SVC obstruction is defined by clinically significant stenosis or obstruction of the SVC as detected by contrast studies. We identified SVC obstruction in seven post-transplant cases and one pre-transplant case. All eight patients had previous or current history of indwelling central venous catheters. Three recipients experienced operative complications. Five of the seven recipients suffered at least one episode of post-operative SVC obstruction or bleeding despite prophylactic anticoagulation. At a median follow-up of 29 months, six of the seven patients transplanted are well. Strategies are available to minimize the risks of intra/peri-operative acute life-threatening SVC obstruction in CF patients. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Yovanoff, Mary; Pepley, David; Mirkin, Katelin; Moore, Jason; Han, David; Miller, Scarlett
2017-01-01
While Virtual Reality (VR) has emerged as a viable method for training new medical residents, it has not yet reached all areas of training. One area lacking such development is surgical residency programs where there are large learning curves associated with skill development. In order to address this gap, a Dynamic Haptic Robotic Trainer (DHRT) was developed to help train surgical residents in the placement of ultrasound guided Internal Jugular Central Venous Catheters and to incorporate personalized learning. In order to accomplish this, a 2-part study was conducted to: (1) systematically analyze the feedback given to 18 third year medical students by trained professionals to identify the items necessary for a personalized learning system and (2) develop and experimentally test the usability of the personalized learning interface within the DHRT system. The results can be used to inform the design of VR and personalized learning systems within the medical community. PMID:29123361
Translating research into practice. Implications of the Thunder Project II.
Thompson, C L; White, C; Wild, L R; Morris, A B; Perdue, S T; Stanik-Hutt, J; Puntillo, K A
2001-12-01
The Thunder Project II study described procedural pain in a variety of acute and critical care settings. The procedures studied were turning, tracheal suctioning, wound drain removal, nonburn wound dressing change, femoral sheath removal, and central venous catheter insertion. Turning had the highest mean pain intensity, whereas femoral sheath removal and central venous catheter insertion had the least pain intensity in adults. Nonwound dressing change had the highest pain intensity for teenagers. Pain occurred in procedures that are often repeated several times a day as well as in those that may be single events. There is a wide range of pain responses to any of these procedures; as a result, standardized and thoughtful pain, and distress assessments are warranted. Planning of care, including the use of preemptive analgesic interventions, needs to be individualized. Future studies are needed to describe patient responses to other commonly performed nursing procedures and to identify effective interventions for reducing procedural pain and distress.
Asghar, Samie; Shamim, Faisal
2017-01-01
A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically. PMID:29284881
Asghar, Samie; Shamim, Faisal
2017-01-01
A young male underwent decompressive craniotomy for an intracerebral bleed. A right-sided subclavian central venous catheter was placed in the operating room after induction of anesthesia. Postoperatively, he was shifted to Intensive Care Unit (ICU) for mechanical ventilation due to low Glasgow coma scale. He had an episode of severe agitation and straining on the tracheal tube in the evening same day. On the 2 nd postoperative day in ICU, his airway pressures were high, and chest X-ray revealed massive pleural effusion on right side. Under ultrasound guidance, 1400 milky white fluid was aspirated. It was sent for analysis (triglycerides) that confirmed chyle and hence, chylothorax was made as diagnosis. A duplex scan was done which ruled out thrombosis in subclavian vein. The catheter had normal pressure tracing with free aspiration of blood from all ports. Enteral feeding was continued as it is a controversial matter in the literature and he was monitored clinically and radiologically.
Central venous access and handwashing: variability in policies and practices.
Galway, Robyn; Harrod, Mary Ellen; Crisp, Jackie; Donnellan, Robyn; Hardy, Jan; Harvey, Alice; Maurice, Lucy; Petty, Sheila; Senner, Anne
2003-12-01
This study examined variability in handwashing policy between hospitals, variability in handwashing practices in nurses and how practice differed from policy in tertiary paediatric hospitals in Australia and New Zealand. Eight of the possible nine major paediatric hospitals provided a copy of their handwashing and/or central venous access device (CVAD) policies, and 67 nurses completed a survey on their handwashing practices associated with CVAD management. A high degree of variability was found in relation to all the questions posed in the study. There was little consistency between policies and little agreement between policies and clinical practice, with many nurses washing for longer than required by policy. Rigour of handwashing also varied according to the procedure undertaken and the type of CVAD with activities undertaken farther from the insertion site of the device more likely to be performed using a clean rather than an aseptic handwashing technique. As both patients and nursing staff move within and between hospitals, a uniform and evidence-based approach to handwashing is highly desirable.
Peripheral Edema, Central Venous Pressure, and Risk of AKI in Critical Illness
Chen, Kenneth P.; Cavender, Susan; Lee, Joon; Feng, Mengling; Mark, Roger G.; Celi, Leo Anthony; Mukamal, Kenneth J.
2016-01-01
Background and objectives Although venous congestion has been linked to renal dysfunction in heart failure, its significance in a broader context has not been investigated. Design, setting, participants, & measurements Using an inception cohort of 12,778 critically ill adult patients admitted to an urban tertiary medical center between 2001 and 2008, we examined whether the presence of peripheral edema on admission physical examination was associated with an increased risk of AKI within the first 7 days of critical illness. In addition, in those with admission central venous pressure (CVP) measurements, we examined the association of CVPs with subsequent AKI. AKI was defined using the Kidney Disease Improving Global Outcomes criteria. Results Of the 18% (n=2338) of patients with peripheral edema on admission, 27% (n=631) developed AKI, compared with 16% (n=1713) of those without peripheral edema. In a model that included adjustment for comorbidities, severity of illness, and the presence of pulmonary edema, peripheral edema was associated with a 30% higher risk of AKI (95% confidence interval [95% CI], 1.15 to 1.46; P<0.001), whereas pulmonary edema was not significantly related to risk. Peripheral edema was also associated with a 13% higher adjusted risk of a higher AKI stage (95% CI, 1.07 to 1.20; P<0.001). Furthermore, levels of trace, 1+, 2+, and 3+ edema were associated with 34% (95% CI, 1.10 to 1.65), 17% (95% CI, 0.96 to 1.14), 47% (95% CI, 1.18 to 1.83), and 57% (95% CI, 1.07 to 2.31) higher adjusted risk of AKI, respectively, compared with edema-free patients. In the 4761 patients with admission CVP measurements, each 1 cm H2O higher CVP was associated with a 2% higher adjusted risk of AKI (95% CI, 1.00 to 1.03; P=0.02). Conclusions Venous congestion, as manifested as either peripheral edema or increased CVP, is directly associated with AKI in critically ill patients. Whether treatment of venous congestion with diuretics can modify this risk will require further study. PMID:26787777
Genetics Home Reference: Stargardt macular degeneration
... called the macula. The macula is responsible for sharp central vision, which is needed for detailed tasks ... STARGARDT DISEASE 3 Sources for This Page Molday RS, Zhang K. Defective lipid transport and biosynthesis in ...
Persistent Bloodstream Infection with Kocuria rhizophila Related to a Damaged Central Catheter
Becker, Karsten; Mérens, Audrey; Ferroni, Agnès; Dubern, Béatrice; Vu-Thien, Hoang
2012-01-01
A case of persistent bloodstream infection with Kocuria rhizophila related to a damaged central venous catheter in a 3-year-old girl with Hirschsprung's disease is reported. The strain was identified as K. rhizophila by 16S rRNA gene sequencing and matrix-assisted laser desorption ionization–time of flight mass spectrometry. Arbitrarily primed PCR analysis showed a clonal strain. The repeated septic episodes were resolved with the catheter repair. PMID:22259211
Enhanced central venous catheter bundle for pediatric parenteral-dependent intestinal failure.
Ormsby, Jennifer A; Bukoye, Bola; Lajoie, Debra; Shermont, Herminia; Martin, Lisa; Leger, Kierrah; Mahoney, Judy; Potter-Bynoe, Gail; Carpenter, Jane; Ozonoff, Al; Lee, Grace M
2018-05-16
Central line-associated bloodstream infections (CLABSIs) cause substantial morbidity and increase antimicrobial use and length of stay among hospitalized children in the United States. CLABSI occurs more frequently among high-risk pediatric patients, such as those with intestinal failure (IF) who are parenteral nutrition (PN) dependent. Following an increase in CLABSI rates, a quality improvement (QI) initiative was implemented. Using QI methodology, an enhanced central venous catheter (CVC) maintenance bundle was developed and implemented on 2 units for pediatric PN-dependent patients with IF. CLABSI rates were prospectively monitored pre- and postimplementation, and bundle element adherence was monitored. Enhanced bundle elements included chlorhexidine-impregnated patch, daily bathing, ethanol locks, 2 nurses for CVC care in a distraction-free zone, peripheral laboratory draws, bundling routine laboratory tests, and PN administration set changes every 24 hours. Adherence to enhanced bundle elements increased to >90% over 3 months. CLABSI rates averaged 1.41 per 1,000 central line days preimplementation compared with 0.40 per 1,000 device days postimplementation (P = .003), an 85% absolute reduction in CLABSI rates over 12 months. Patients with IF are at an increased risk for CLABSI. Enhanced CVC maintenance bundles that specifically target prevention practices in this population may be beneficial. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Martin, R. G. (Editor); Atkinson, D. J.; James, M. L.; Lawson, D. L.; Porta, H. J.
1990-01-01
The development and application of the Spacecraft Health Automated Reasoning Prototype (SHARP) for the operations of the telecommunications systems and link analysis functions in Voyager mission operations are presented. An overview is provided of the design and functional description of the SHARP system as it was applied to Voyager. Some of the current problems and motivations for automation in real-time mission operations are discussed, as are the specific solutions that SHARP provides. The application of SHARP to Voyager telecommunications had the goal of being a proof-of-capability demonstration of artificial intelligence as applied to the problem of real-time monitoring functions in planetary mission operations. AS part of achieving this central goal, the SHARP application effort was also required to address the issue of the design of an appropriate software system architecture for a ground-based, highly automated spacecraft monitoring system for mission operations, including methods for: (1) embedding a knowledge-based expert system for fault detection, isolation, and recovery within this architecture; (2) acquiring, managing, and fusing the multiple sources of information used by operations personnel; and (3) providing information-rich displays to human operators who need to exercise the capabilities of the automated system. In this regard, SHARP has provided an excellent example of how advanced artificial intelligence techniques can be smoothly integrated with a variety of conventionally programmed software modules, as well as guidance and solutions for many questions about automation in mission operations.
Mixed venous oxygen saturation monitoring revisited: thoughts for critical care nursing practice.
Christensen, Martin
2012-05-01
Less invasive methods of determining cardiac output are now readily available. Using indicator dilution technique, for example has made it easier to continuously measure cardiac output because it uses the existing intra-arterial line. Therefore gone is the need for a pulmonary artery floatation catheter and with it the ability to measure left atrial and left ventricular work indices as well the ability to monitor and measure a mixed venous saturation (SvO(2)). The aim of this paper is to put forward the notion that SvO(2) provides valuable information about oxygen consumption and venous reserve; important measures in the critically ill to ensure oxygen supply meets cellular demand. In an attempt to portray this, a simplified example of the septic patient is offered to highlight the changing pathophysiological sequelae of the inflammatory process and its importance for monitoring SvO(2). SvO(2) monitoring, it could be argued, provides the gold standard for assessing arterial and venous oxygen indices in the critically ill. For the bedside ICU nurse the plethora of information inherent in SvO(2) monitoring could provide them with important data that will assist in averting potential problems with oxygen delivery and consumption. However, it has been suggested that central venous saturation (ScvO(2)) might be an attractive alternative to SvO(2) because of its less invasiveness and ease of obtaining a sample for analysis. There are problems with this approach and these are to do with where the catheter tip is sited and the nature of the venous admixture at this site. Studies have shown that ScvO(2) is less accurate than SvO(2) and should not be used as a sole guiding variable for decision-making. These studies have demonstrated that there is an unacceptably wide range in variance between ScvO(2) and SvO(2) and this is dependent on the presenting disease, in some cases SvO(2) will be significantly lower than ScvO(2). Whilst newer technologies have been developed to continuously measure cardiac output, SvO(2) monitoring is still an important adjunct to clinical decision-making in the ICU. Given the information that it provides, seeking alternatives such as ScvO(2) or blood samples obtained from femorally placed central venous lines, can unnecessarily lead to inappropriate treatment being given or withheld. Instead when using ScvO(2), trending of this variable should provide clinical determinates that are useable for the bedside ICU nurse, remembering that in most conditions SvO(2) will be approximately 16% lower. Copyright © 2011 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Central venous catheter-related bloodstream infections in the intensive care unit
Patil, Harsha V.; Patil, Virendra C.; Ramteerthkar, M. N.; Kulkarni, R. D.
2011-01-01
Context: Central venous catheter-related bloodstream infection (CRBSI) is associated with high rates of morbidity and mortality in critically ill patients. Aims: This study was conducted to determine the incidence of central venous catheter-related infections (CRIs) and to identify the factors influencing it. So far, there are very few studies that have been conducted on CRBSI in the intensive care unit in India. Settings and Design: This was a prospective, observational study carried out in the medical intensive care unit (MICU) over a period of 1 year from January to December 2004. Materials and Methods: A total of 54 patients with indwelling central venous catheters of age group between 20 and 75 years were included. The catheters were cultured using the standard semiquantitative culture (SQC) method. Statistical analysis used SPSS-10 version statistical software. Results: A total of 54 CVC catheters with 319 catheter days were included in this study. Of 54 patients with CVCs studied for bacteriology, 39 (72.22%) catheters showed negative SQCs and also negative blood cultures. A total of 15 (27.77%) catheters were positive on SQC, of which 10 (18.52%) were with catheter-associated infection and four (7.41%) were with catheter-associated bacteremia; the remaining one was a probable catheter-associated bacteremia. CRIs were high among catheters that were kept in situ for more than 3 days and emergency procedures where two or more attempts were required for catheterization (P < 0.05). In multivariate analysis of covariance duration of catheter in situ for >3 days, inexperienced venupucturist, more number of attempts and emergency CVC were associated with more incidence of CVCBSIs, with P <0.02. The duration of catheter in situ was negatively correlated (-0.53) and number of attempts required to put CVC was positively correlated (+0.39) with incidence of CVCBSIs. Sixty-five percent of the isolates belonged to the CONS group (13/20). Staphylococcus epidermidis showed maximum susceptibility to amikacin, doxycycline and amoxycillin with clavulanic acid and was susceptible to vancomycin (100%). Klebsiella pneumoniae was 100% susceptible to amikacin and ciprofloxacin. Escherichia coli was susceptible to amikacin and cefotaxime. Conclusions: The overall incidence of CRI was 27.77% (15/54). Catheter-associated BSIs were 47.31 per 1000 catheter-days. CRI was low in the catheters inserted by the experienced venipuncturists, elective procedure and CVC kept in situ for ≤3 days. S. epidermidis was the most common isolate. PMID:22346032
1987-03-01
South Dakota 13 2 Description of the Lower Brule Section MT-i, now submerged by the waters of Lake Sharpe, Lyman County, South Dakota 15 3 Sequence...MT-i, now submerged by the waters of Lake Sharpe, Lyman County, South Dakota Unit # Description Thickness 1 Gray, thinbedded Cretaceous Pierre Shale...14,000 10000 C- 14 YBP WISCONSlNAN HOLOCENE AGE LATE EARLY MIDDLE LATE 10 M.I1. AGGIE BROWN PICK CITY OW MID.UPE MBR MEMBER M EMBER RIVERDALE MEMBER OAHE
Karadeli, E; Tarhan, N C; Ulu, E M Kayahan; Tutar, N U; Basaran, O; Coskun, M; Niron, E A
2009-01-01
To evaluate failing hemodialysis fistula complications using 16-detector MDCTA, and to assess the accuracies of different 3D planes. Thirty patients (16 men, 14 women, aged 27-79 years) were referred for hemodialysis access dysfunction. Thirty-one MDCTA exams were done prior to fistulography. For MDCTA, contrast was administered (2mL/kg at 5mL/s) via a peripheral vein in the contralateral arm. Axial MIP, coronal MIP, and VRT images were constructed. Venous complications were evaluated on axial source images, on each 3D plane, and on all-planes together. Results were analyzed using McNemar test. Axial MIP, VRT and all-planes evaluations were most sensitive for fistula site detection (93%). Coronal MIP had the highest sensitivity, specificity and accuracy (35%, 96%, and 85%, respectively) for detecting venous stenosis. VRT and all-planes had the highest sensitivity and accuracy for detecting aneurysms (100%). All-planes and axial MIP were most sensitive for detecting venous occlusion (61% and 54%). Comparisons of detection frequencies for each venous pathology between the five categories of MDCTA revealed no significant differences (P>0.05). MDCTA additionally showed 3 partially thrombosed aneurysms, 4 anastomosis site stenosis and 12 arterial complications. MDCTA overall gives low sensitivity for detection of central vein stenosis and moderate sensitivity for occlusion. For most pathology, all-planes evaluation of MDCTA gives highest sensitivity and accuracy rates when compared to other planes. For venous stenosis and occlusion, MDCTA should be considered when ultrasonography and fistulography are inconclusive. MDCTA is helpful in identifying aneurysms, collaterals, partial venous thromboses and additional arterial, anastomosis site pathologies.
5-fluorouracil extravasation following port failure.
Nesti, S P; Kovac, R
2000-01-01
A case is presented of cytotoxic extravasation as a result of an implantable venous port being perforated by a standard Huber needle. A patient receiving 5-fluorouracil via a dual reservoir port, implanted within the left chest wall, presented with hemoserous discharge from the right needle entry site. The left chest wall was warm to touch, erythematous, and swollen. Subcutaneous infiltration was suspected, and the infusion was ceased. A venogram was performed demonstrating significant extravasation around the left reservoir only. On port removal, inspection showed the Huber needle had penetrated the base plate on the left side. It is recommended that this complication be added as a possible sequelae of central venous port use.
Cross-over endovascular retrieval of a lost guide wire from the subclavian vein.
Struck, M F; Kaden, I; Heiser, A; Steen, M
2008-01-01
The lost guidewire in central venous catheterization is a commonly described complication. The percutaneous endovascular retrieval method is safe and has a very low complication rate. Guidewires extending to the inferior cava vein are usually retrieved via the femoral vein. Under special circumstances, femoral venous access may be impossible and alternative vascular approaches are required. We report a case in which we used an alternative vascular approach, from the subclavian site contralateral to the insertion, in a patient with extensive inguinal burn injuries. Cross-over subclavian retrieval can be an alternative approach for retrieval of a lost guidewire, but it involves an increased risk of puncture-related complications such as pneumothorax.
Combustion Noise at Elevated Pressures in a Liquid-Fueled Premixed Combustor
NASA Technical Reports Server (NTRS)
Darling, Douglas; Radhakrishnan, Krishnan; Oyediran, Ayo
1997-01-01
Noise generated in gas turbine combustors can exist in several forms-broadband noise, sharp resonant peaks, and regular or intermittent nonlinear pulsing. In the present study, dynamic pressure measurements were made in several JP-5-fueled combustor configurations, at various mean pressures and temperatures. The fluctuating pressure was measured at mean pressures from 6 to 14 atm and inlet temperatures from 550 K to 850 K. The goal of the present work was to study the effect of changes in mean flow conditions on combustor noise: both broadband noise and sharp tones were considered. In general, the shape of the broadband noise spectrum was consistent from one configuration to another. The shape of the spectrum was influenced by the acoustic filtering of the combustion zone. This filtering ensured the basic consistency of the spectra. In general, the trends in broadband noise observed at low mean pressures were also seen at high mean pressures; that is, the total sound level decreased with both increasing equivalence ratio and increasing inlet temperature. The combustor configurations without a central pilot experienced higher broadband noise levels and were more susceptible to narrow peak resonances than configurations with a central pilot. The sharp peaks were more sensitive to the mean flow than was the broadband noise, and the effects were not always the same. In some situations, increasing the equivalence ratio made the sharp peaks grow, while at other conditions, increasing the equivalence ratio made the sharp peaks shrink. Thus, it was difficult to predict when resonances would occur; however, they were reproducible. Acoustic coupling between the upstream and downstream regions of the combustor may play a role in the sharp-peaked oscillations. Noise was also observed near lean blow out. As with other types of noise, lean blow out noise was affected by the combustion chamber acoustics, which apparently maintains the fluctuations at a uniform frequency. However, the actual conditions when this type of noise was experienced appeared to simply follow the lean blow out limit as it varied with mean temperature and pressure.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... Considered HAC Candidate: Iatrogenic Pneumothorax With Venous Catheterization 3. Present on Admission (POA.... History of Measures Adopted for the Hospital IQR Program b. Maintenance of Technical Specifications for...-Associated Infection (HAI) Measures (A) Proposed Central Line Associated Blood Stream Infections ((CLABSI...
Catheter-related bloodstream infections
Gahlot, Rupam; Nigam, Chaitanya; Kumar, Vikas; Yadav, Ghanshyam; Anupurba, Shampa
2014-01-01
Central-venous-catheter-related bloodstream infections (CRBSIs) are an important cause of hospital-acquired infection associated with morbidity, mortality, and cost. Consequences depend on associated organisms, underlying pre-morbid conditions, timeliness, and appropriateness of the treatment/interventions received. We have summarized risk factors, pathogenesis, etiology, diagnosis, and management of CRBSI in this review. PMID:25024944
Li, Bo; Zhao, Yanxiang
2013-01-01
Central in a variational implicit-solvent description of biomolecular solvation is an effective free-energy functional of the solute atomic positions and the solute-solvent interface (i.e., the dielectric boundary). The free-energy functional couples together the solute molecular mechanical interaction energy, the solute-solvent interfacial energy, the solute-solvent van der Waals interaction energy, and the electrostatic energy. In recent years, the sharp-interface version of the variational implicit-solvent model has been developed and used for numerical computations of molecular solvation. In this work, we propose a diffuse-interface version of the variational implicit-solvent model with solute molecular mechanics. We also analyze both the sharp-interface and diffuse-interface models. We prove the existence of free-energy minimizers and obtain their bounds. We also prove the convergence of the diffuse-interface model to the sharp-interface model in the sense of Γ-convergence. We further discuss properties of sharp-interface free-energy minimizers, the boundary conditions and the coupling of the Poisson-Boltzmann equation in the diffuse-interface model, and the convergence of forces from diffuse-interface to sharp-interface descriptions. Our analysis relies on the previous works on the problem of minimizing surface areas and on our observations on the coupling between solute molecular mechanical interactions with the continuum solvent. Our studies justify rigorously the self consistency of the proposed diffuse-interface variational models of implicit solvation.
The Dysfunctions of Bureaucratic Structure.
ERIC Educational Resources Information Center
Duttweiler, Patricia Cloud
1988-01-01
Numerous dysfunctions result from bureaucratic school organization, including an overemphasis on specialized tasks, routine operating rules, and formal procedures for managing teaching and learning. Such schools are characterized by numerous regulations; formal communications; centralized decision making; and sharp distinctions among…
Lower Body Negative Pressure: Historical Perspective, Research Findings, and Clinical Applications.
Crystal, George J; Salem, M Ramez
2015-04-01
Lower body negative pressure (LBNP) is a technique that redistributes blood from the upper body to the dependent regions of the pelvis and legs, thus reducing central venous pressure and venous return. The subject is placed in a cylindrical air-tight metal tank, which is sealed at the level of the iliac crests, and subatmospheric pressure is produced using a vacuum pump. This article reviews the historical background, physiological effects, research findings, and clinical applications of LBNP. LBNP is found in both the basic science and clinical literature, encompassing its diverse investigational and clinical applications. The first references to LBNP were in 1952 describing its effectiveness in inducing hypotensive anesthesia. Major interest in LBNP began in the mid 1960s when it was used to characterize the cardiovascular responses to hemorrhage and orthostatic stress, especially that associated with the weightlessness of space flight; these studies have continued to the present day. Advantages of LBNP for such experimental studies include the following: (1) The degree of central hypovolemia is easily controlled and has a rapid onset and reversal. (2) The technique is repeatable, reproducible, and noninvasive. (3) No exogenous pharmacologic agent is required to produce venous pooling. (4) The findings are independent of gravity. In recent years, a few institutions have applied LBNP clinically to diagnose abnormalities in cardiovascular autonomic function and, when combined with echocardiography, to uncover changes in cardiac performance through analysis of Starling curves. Copyright © 2015 Anesthesia History Association. Published by Elsevier Inc. All rights reserved.
Elevated central venous pressure: A consequence of exercise training-induced hypervolemia
NASA Technical Reports Server (NTRS)
Convertino, Victor A.; Mack, Gary W.; Nadel, Ethan R.
1990-01-01
Resting plasma volumes, and arterial and central venous pressures (CVP) were measured in 16 men before and after exercise training to determine if training-induced hypervolemia could be explained by a change in total vascular capacitance. In addition, resting levels of plasma vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (ALD), and norepinephrine (NE) were measured before and after training. The same measurements of vacular volume, pressures, and plasma hormones were measured in 8 subjects who did not undergo exercise and acted as controls. The exercise training program consisted of 10 weeks of controlled cycle exercise for 30 min/d, 4 d/wk at 75 to 80 percent of maximal oxygen uptake (VO2max). A training effect was verified by a 20 percent increase in VO2max, a resting bradycardia, and a 370 ml (9 percent) increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased. The percent change in blood volume from before to after training was linearly related to the percent change in CVP. As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was essentially unchanged following exercise training. Plasma AVP, ANP, ALD, and NE were unaltered. Results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance. This may represent a resetting of the pressure-volume stimulus-response relation for regulation of blood volume.
Paglialonga, Fabio; Artoni, Andrea; Braham, Simon; Consolo, Silvia; Giannini, Alberto; Chidini, Giovanna; Napolitano, Luisa; Martinelli, Ida; Montini, Giovanni; Edefonti, Alberto
2016-05-01
To date, no study has investigated the use of vitamin K antagonists (VKA) in children undergoing chronic haemodialysis (HD) with a central venous catheter (CVC). Consecutive patients aged <18 years with a newly placed tunnelled CVC for chronic HD were enrolled over a 3-year period. Children with active nephrotic syndrome or a history of venous thrombosis received warfarin (VKA group) with therapeutic target international normalised ratios of between 2.0 and 3.0. Patients at standard risk of CVC malfunction were not treated with VKA (standard group). The primary end-point was overall CVC survival. The VKA group consisted of nine patients (median age 10.6 years; range 1.2-15.3 years) with 11 CVC, and the standard group comprised eight patients (11.8 years; 6.1-17.3 years) with ten CVC. The 6- and 12-month CVC survival was significantly longer in the VKA group than in the standard group (100 vs. 60 % and 83.3 vs. 16.7 %, respectively; p < 0.05), with a median survival of 369 and 195 days, respectively (p < 0.05). None of the CVC in the VKA group required removal due to malfunction, as compared to four in the standard group. No major bleeding episodes occurred in either group. Therapy with VKA would appear to be safe in children on chronic HD and may improve CVC survival in patients at increased risk of CVC thrombosis.
Chang, Yi-Fang; Lo, An-Chi; Tsai, Chung-Hsin; Lee, Pei-Yi; Sun, Shen; Chang, Te-Hsin; Chen, Chien-Chuan; Chang, Yuan-Shin; Chen, Jen-Ruei
2013-02-01
Totally implantable port systems are generally recommended for prolonged central venous access in diverse settings, but their risk of complications remains unclear for patients with advanced cancer. The aim of this study was to assess the risk of port system failure in patients with advanced cancer. We conducted a retrospective cohort study in a comprehensive cancer centre. A detailed chart review was conducted among 566 patients with 573 ports inserted during January-June, 2009 (average 345.3 catheter-days). Cox regression analysis was applied to evaluate factors during insertion and early maintenance that could lead to premature removal of the port systems due to infection or occlusion. Port system-related infection was significantly associated with receiving palliative care immediately after implantation (hazard ratio, HR = 7.3, 95% confidence interval, 95% CI = 1.2-46.0), after adjusting for probable confounders. Primary cancer site also impacted the occurrence of device-related infection. Receiving oncologic/palliative care (HR = 3.0, P = 0.064), advanced cancer stage (HR = 6.5, P = 0.077) and body surface area above 1.71 m(2) (HR = 3.4, P = 0.029) increased the risk of port system occlusion. Our study indicates that totally implantable port systems yield a higher risk of complications in terminally ill patients. Further investigation should be carefully conducted to compare outcomes of various central venous access devices in patients with advanced cancer and to develop preventive strategies against catheter failure.
Amyloid-β efflux from the CNS into the plasma
Roberts, Kaleigh Filisa; Elbert, Donald L.; Kasten, Tom P.; Patterson, Bruce W.; Sigurdson, Wendy C.; Connors, Rose E.; Ovod, Vitaliy; Munsell, Ling Y.; Mawuenyega, Kwasi G.; Miller-Thomas, Michelle M.; Moran, Christopher J.; Cross, Dewitte T.; Derdeyn, Colin P.; Bateman, Randall J.
2015-01-01
Objective The aim of this study was to measure the flux of amyloid-β (Aβ) across the human cerebral capillary bed in order to determine if transport into the blood is a significant mechanism of clearance for Aβ produced in the central nervous system (CNS). Methods Time-matched blood samples were simultaneously collected from a cerebral vein (including the sigmoid sinus, inferior petrosal sinus, and the internal jugular vein), femoral vein, and radial artery of patients undergoing Inferior Petrosal Sinus Sampling (IPSS). For each plasma sample, Aβ concentration was assessed by three assays and the venous to arterial Aβ concentration ratios were determined. Results Aβ concentration was increased by ~7.5% in venous blood leaving the CNS capillary bed compared to arterial blood, indicating efflux from the CNS into the peripheral blood (p < 0.0001). There was no difference in peripheral venous Aβ concentration compared to arterial blood concentration. Interpretation Our results are consistent with clearance of CNS-derived Aβ into the venous blood supply with no increase from a peripheral capillary bed. Modeling these results suggests that direct transport of Aβ across the blood-brain barrier accounts for ~25% of Aβ clearance, and reabsorption of cerebrospinal fluid Aβ accounts for ~25% of the total CNS Aβ clearance in humans. PMID:25205593
Epidural varix at the cervicothoracic junction: unusual cause of quadriplegia: a case report.
Bapat, Mihir; Metkar, Umesh
2006-02-01
A case report describing an unusual incident of quadriplegia in a young adult male caused by an epidural varix at the cervicothoracic junction. To report an unusual case of quadriplegia caused by an epidural varix at the cervicothoracic junction. Epidural varices are dilated tortuous elongated veins inside the central canal. In degenerative spinal stenosis, these varices are a result of venous stagnation and contribute to the pathogenesis of radicular pain. In the absence of stenosis, primary varicosities develop as a result of dynamic obstruction to venous outflow during spinal movements. A primary epidural varix can produce neurologic deficit similar to a space occupying lesion within the spinal canal. The myeloradiculopathy is of a slow progressive nature. A young man presented with an acute onset flaccid quadriplegia in the absence of significant trauma. Magnetic resonance imaging revealed an extradural space occupying lesion at the cervicothoracic junction that was diagnosed as an isolated epidural varix during surgery. No neurologic recovery occurred. Postoperative magnetic resonance imaging revealed a syrinx in the cervicothoracic cord. In the absence of other precipitating factors, the cord injury was attributed to the epidural varix. A temporary impedance to the venous outflow with the increase in the venous pressure has been hypothesized as the mechanism of cord injury.
Lamsfus-Prieto, J Á; de Castro-Fernández, R; Hernández-García, A M; Marcano-Rodriguez, G
2016-04-01
The anaerobic metabolism is the cornerstone in physiopathology of septic shock. Nowadays we have both the central or mixed venous oxygen saturation and lactate levels to monitoring the metabolism in septic patients. Some studies have shown that normalization of systemic hemodynamic and oxygen metabolism variables not prevent progression to multiorgan damage and death. Recently has been proposed the venous-to-arterial carbon dioxide difference (ΔpvaCO2) as an alternative marker of tissue hypoperfusion, like Cardiac Index. High ΔpvaCO2 predicts adverse outcomes. Also has been proposed both, the ratio between the ΔpvaCO2 and arterial-to-venous oxygen content difference (ΔCavO2): ΔpvaCO2/ΔCavO2; and, the ratio between venous-to-arterial carbon dioxide difference (ΔCvaCO2) and ΔCavO2: ΔCvaCO2/ΔCavO2, as markers of anaerobic metabolism. Both of high ratios are related to high levels of lactate and worse prognosis. Therefore in patients with sepsis the combination of markers of resuscitation could be important to improve the outcomes. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Chen, Yung-Chih; Edinburgh, Robert M; Hengist, Aaron; Smith, Harry A; Walhin, Jean-Philippe; Betts, James A; Thompson, Dylan; Gonzalez, Javier T
2018-06-27
What is the central question of this study? Glucagon-like peptide-1 (GLP-1) is an important obesity/diabetes target, with effects dependent on circulating GLP-1 concentrations. Peripheral tissues extract GLP-1, therefore sampling venous versus arterialised blood may provide different GLP-1 concentrations. This study examined whether arterialisation alters GLP-1 concentrations during fasting and feeding. What is the main finding and its importance? This study demonstrates that venous blood provides lower postprandial, but not fasting, GLP-1 concentrations versus arterialised blood. Therefore, when accurate assessment of postprandial peripheral availability of GLP-1 is required, blood sampling methods should be carefully considered, clearly reported, and arterialisation is recommended. Glucagon-like peptide-1 (GLP-1) displays concentration-dependent effects on metabolism, appetite and angiogenesis, so accurate determination of circulating GLP-1 concentrations is important. This study compared GLP-1 concentrations in venous versus arterialised blood under both fasted and fed conditions. Venous and arterialised blood samples were simultaneously drawn from ten, young, healthy men before, and 30, 60 and 120 min after, ingestion of 75 g glucose. Plasma GLP-1 concentrations increased in response to glucose ingestion (time effect: p < 0.01) and to a lesser extend in venous versus arterialised plasma (time x arterialisation interaction: p < 0.01). Accordingly, the plasma incremental area under the curve was lower in venous versus arterialised plasma (974 ± 88 versus 1214 ± 115 pmol·L x 120 min -1 , respectively, p = 0.049). In the postprandial state, there was a positive relationship between arterialised GLP-1 concentrations and the venous-arterialised difference in GLP-1 concentrations (r 2 = 0.51; p < 0.01). Both arterialised and venous peak GLP-1 concentrations showed positive relationships with peak arterialised insulin concentrations (both r 2 > 0.6, p < 0.01). Venous sampling results in lower concentrations of GLP-1 in the postprandial, but not the fasted state compared to arterialised blood. This absolute difference is biologically meaningful and is magnified when GLP-1 availability is high. Therefore, sampling from arterialised blood may provide a better chance of detecting small differences in postprandial GLP-1 availability with interventions and if absolute GLP-1 concentrations are of interest, the blood sampling method should be carefully considered and clearly reported. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucey, Brian; Varghese, Jose C.; Haslam, Philip
1999-09-15
Purpose: To study the cost and impact on patient management of the routine performance of chest radiographs in patients undergoing imaged-guided central venous catheter insertion. Methods: Six hundred and twenty-one catheters placed in 489 patients over a 42-month period formed the study group. Catheters were placed in the right internal jugular vein (425), left internal jugular vein (133), and subclavian veins (63). At the end of the procedure fluoroscopy was used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. Results: Postprocedural chest fluoroscopy showed no evidence of pneumothorax, hemothorax, or mediastinalmore » hematoma. Inappropriate catheter tip position or catheter kinks were noted with 90 catheters. These problems were all corrected while the patient was on the interventional table. Postprocedural chest radiographs showed no complications but proximal catheter tip migration was noted in six of 621 catheters (1%). These latter six catheters required further manipulation. The total technical and related charges for the postprocedural chest radiographs in this series were estimated at Pounds 15,525. Conclusion: Postprocedural chest radiographs after image-guided central venous catheter insertion are not routinely required. A postprocedural chest radiograph can be performed on a case-by-case basis at the discretion of the interventional radiologist.« less
Garus-Pakowska, Anna; Szatko, Franciszek; Ulrichs, Magdalena
2017-08-10
(1) Background: An analysis of work-related accidents in paramedics in Poland by presenting the model and trend of accidents, accident rates and by identifying causes and results of accidents; (2) Methods: A retrospective analysis of medical documentation regarding work-related accidents in a multi-specialist hospital, located in central Poland, in the period 2005-2015. The study group included paramedics who had an accident while being on duty; (3) Results: According to hospital records, 88 paramedics were involved in 390 accidents and 265 injuries caused by sharp instruments. The annual accident rate was 5.34/100 employed paramedics. Most of the accidents occurred at night. The most common reason for the accident was careless behaviour of the paramedic, which resulted in joint sprains and dislocations. Injuries accounted for a huge portion of the total number of events. As many as 45% of injuries were not officially recorded; (4) Conclusion: High rates of work-related accidents and injuries caused by sharp instruments in paramedics are a serious public health problem. Further studies should be conducted in order to identify risk factors of accidents, particularly injuries, and to implement preventative programmes, aiming to minimise rates of occupational hazards for paramedics.
Szatko, Franciszek; Ulrichs, Magdalena
2017-01-01
(1) Background: An analysis of work-related accidents in paramedics in Poland by presenting the model and trend of accidents, accident rates and by identifying causes and results of accidents; (2) Methods: A retrospective analysis of medical documentation regarding work-related accidents in a multi-specialist hospital, located in central Poland, in the period 2005–2015. The study group included paramedics who had an accident while being on duty; (3) Results: According to hospital records, 88 paramedics were involved in 390 accidents and 265 injuries caused by sharp instruments. The annual accident rate was 5.34/100 employed paramedics. Most of the accidents occurred at night. The most common reason for the accident was careless behaviour of the paramedic, which resulted in joint sprains and dislocations. Injuries accounted for a huge portion of the total number of events. As many as 45% of injuries were not officially recorded; (4) Conclusion: High rates of work-related accidents and injuries caused by sharp instruments in paramedics are a serious public health problem. Further studies should be conducted in order to identify risk factors of accidents, particularly injuries, and to implement preventative programmes, aiming to minimise rates of occupational hazards for paramedics. PMID:28796193
Bonciarelli, Giorgio; Batacchi, Stefano; Biffi, Roberto; Buononato, Massimo; Damascelli, Bruno; Ghibaudo, Flavio; Orsi, Franco; Pittiruti, Mauro; Scoppettuolo, Giancarlo; Verzè, Alessia; Borasi, Guido; De Cicco, Marcello; Dosio, Roberto; Gazzo, Paolo; Maso, Renzo; Roman, Alessandro; Ticha, Vladimira; Venier, Giacomo; Blackburn, Paul; Goossens, Godelieve A; Bowen Santolucito, Jamie; Stas, Marguerite; Van Boxtel, Ton; Vesely, Thomas M; de Lutio, Enrico
2011-01-01
The use of totally implantable venous access devices in radiology may be associated with complications such as occlusion of the system (because of the high density of some contrast), infection (if the port is not handled in aseptic conditions, using proper barrier protections), and mechanical complications due to the high-pressure administration of contrast by automatic injectors (so-called power injector), including extravasation of contrast media into the soft tissues, subintimal venous or myocardial injection, or serious damage to the device itself (breakage of the external connections, dislocation of the non-coring needle, or breakage of the catheter). The last problem - i.e., the damage of the device from a power injection - is not an unjustified fear, but a reality. A warning by the US Food and Drug Administration of July 2004 reports around 250 complications of this kind, referring to both port and central venous catheters and peripherally inserted central catheter systems, which occurred over a period of several years; in all cases, the damage occurred during the injection of contrast material by means of power injectors for computed tomography or magnetic resonance imaging procedures. Though the risk associated with the use of ports in radiodiagnostics is thus clear, it has been suggested that administration of the contrast material via the port may have some advantage in terms of image quality, increased comfort for the patient, and maybe more accurate reproducibility of the patient's own follow-up exams. This contention needs to be supported by evidence. Also, since many cancer patients who need frequent computed tomography studies already have totally implantable systems, it would seem reasonable to try to define how and when such systems may safely be used. The purpose of this consensus statement is to define recommendations based on the best available evidence, for the safe use of implantable ports in radiodiagnostics.
Cairns, Simeon P; Inman, Luke A G; MacManus, Caroline P; van de Port, Ingrid G L; Ruell, Patricia A; Thom, Jeanette M; Thompson, Martin W
2017-08-01
To determine the roles of calcium (Ca 2+ ) handling by sarcoplasmic reticulum (SR) and central activation impairment (i.e., central fatigue) during fatigue with repeated maximal voluntary isometric contractions (MVC) in human muscles. Contractile performance was assessed during 3 min of repeated MVCs (7-s contraction, 3-s rest, n = 17). In ten participants, in vitro SR Ca 2+ -handling, metabolites, and fibre-type composition were quantified in biopsy samples from quadriceps muscle, along with plasma venous [K + ]. In 11 participants, central fatigue was compared using tetanic stimulation superimposed on MVC in quadriceps and adductor pollicis muscles. The decline of peak MVC force with fatigue was similar for both muscles. Fatigue resistance correlated directly with % type I fibre area in quadriceps (r = 0.77, P = 0.009). The maximal rate of ryanodine-induced Ca 2+ -release and Ca 2+ -uptake fell by 31 ± 26 and 28 ± 13%, respectively. The tetanic force depression was correlated with the combined reduction of ATP and PCr, and increase of lactate (r = 0.77, P = 0.009). Plasma venous [K + ] increased from 4.0 ± 0.3 to 5.4 ± 0.8 mM over 1-3-min exercise. Central fatigue occurred during the early contractions in the quadriceps in 7 out of 17 participants (central activation ratio fell from 0.98 ± 0.05 to 0.86 ± 0.11 at 1 min), but dwindled at exercise cessation. Central fatigue was seldom apparent in adductor pollicis. Fatigue with repeated MVC in human limb muscles mainly involves peripheral aspects which include impaired SR Ca 2+ -handling and we speculate that anaerobic metabolite changes are involved. A faster early force loss in quadriceps muscle with some participants is attributed to central fatigue.
Arvaniti, Kostoula; Lathyris, Dimitrios; Blot, Stijn; Apostolidou-Kiouti, Fani; Koulenti, Despoina; Haidich, Anna-Bettina
2017-04-01
Selection of central venous catheter insertion site in ICU patients could help reduce catheter-related infections. Although subclavian was considered the most appropriate site, its preferential use in ICU patients is not generalized and questioned by contradicted meta-analysis results. In addition, conflicting data exist on alternative site selection whenever subclavian is contraindicated. To compare catheter-related bloodstream infection and colonization risk between the three sites (subclavian, internal jugular, and femoral) in adult ICU patients. We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled trials, CINAHL, and ClinicalTrials.gov. Eligible studies were randomized controlled trials and observational ones. Extracted data were analyzed by pairwise and network meta-analysis. Twenty studies were included; 11 were observational, seven were randomized controlled trials for other outcomes, and two were randomized controlled trials for sites. We evaluated 18,554 central venous catheters: 9,331 from observational studies, 5,482 from randomized controlled trials for other outcomes, and 3,741 from randomized controlled trials for sites. Colonization risk was higher for internal jugular (relative risk, 2.25 [95% CI, 1.84-2.75]; I = 0%) and femoral (relative risk, 2.92 [95% CI, 2.11-4.04]; I = 24%), compared with subclavian. Catheter-related bloodstream infection risk was comparable for internal jugular and subclavian, higher for femoral than subclavian (relative risk, 2.44 [95% CI, 1.25-4.75]; I = 61%), and lower for internal jugular than femoral (relative risk, 0.55 [95% CI, 0.34-0.89]; I = 61%). When observational studies that did not control for baseline characteristics were excluded, catheter-related bloodstream infection risk was comparable between the sites. In ICU patients, internal jugular and subclavian may, similarly, decrease catheter-related bloodstream infection risk, when compared with femoral. Subclavian could be suggested as the most appropriate site, whenever colonization risk is considered and not, otherwise, contraindicated. Current evidence on catheter-related bloodstream infection femoral risk, compared with the other sites, is inconclusive.
Plasma transfusions prior to insertion of central lines for people with abnormal coagulation
Hall, David P; Estcourt, Lise J; Doree, Carolyn; Hopewell, Sally; Trivella, Marialena; Walsh, Timothy S
2016-01-01
Background The insertion of central venous catheters (CVCs) may be associated with peri- and post-procedural bleeding. People who require a central line often have disorders of coagulation as a result of their underlying illness, co-morbidities or the effects of treatment. Clinical practice in some institutions is to mitigate the risk of bleeding in these patients by prophylactically transfusing fresh frozen plasma (FFP) in order to correct clotting factor deficiencies prior to central line insertion. However, FFP transfusion is not without risk, and it remains unclear whether this intervention is associated with reduced rates of bleeding or other clinically-meaningful outcomes. Objectives To assess the effect of different prophylactic plasma transfusion regimens prior to central line insertion in people with abnormal coagulation. Search methods We searched for randomised controlled trials (RCTs) in the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2016, Issue 3), PubMed (e-publications only), Ovid MEDLINE (from 1946), Ovid Embase (from 1974), the Transfusion Evidence Library (from 1950) and ongoing trial databases to 1 March 2016. Selection criteria We included RCTs involving transfusions of plasma to prevent bleeding in people of any age with abnormal coagulation requiring insertion of a central venous catheter, published in English. Data collection and analysis We used standard methodological procedures expected by Cochrane. Main results We identified four trials eligible for inclusion, of which three are ongoing. We did not exclude any studies because they were not published in English. The included study randomised 81 adults in intensive care whose INR (International Normalised Ratio) was greater than or equal to 1.5 to no FFP or to a single dose of 12 mL/kg FFP prior to undergoing central venous catheterisation (58 participants) or other invasive procedure (23 participants). It is the subgroup of 58 adults undergoing CVC insertion that were included in this review, the study authors provided unpublished data for this review’s outcomes. The quality of the evidence was low or very low across different outcomes according to the GRADE methodology. The included study was at high risk of bias due to lack of blinding of participants and personnel and imbalance in the number of participants who had liver disease between study arms. There was insufficient evidence to determine a difference in major procedure-related bleeding within 24 hours (one RCT; 58 participants; no events in either study arm, very low-quality evidence). We are very uncertain whether FFP reduces minor procedure-related bleeding within 24 hours of the study (one RCT; 58 participants, RR 0.67, 95% CI 0.12 to 3.70, very low-quality evidence). No studies were found that looked at: all-cause mortality; the proportion of participants receiving plasma or red cell transfusions; serious adverse reactions (transfusion or line-related complications); number of days in hospital; change in INR; or quality of life. The three ongoing studies are still recruiting participants (expected recruitment: up to 355 participants in total). and are due to be completed by February 2018. Authors’ conclusions There is only very limited evidence from one RCT to inform the decision whether or not to administer prophylactic plasma prior to central venous catheterisation for people with abnormal coagulation. It is not possible from the current RCT evidence to recommend whether or not prophylactic plasma transfusion is beneficial or harmful in this situation. The three ongoing RCTs will not be able to answer this review’s questions, because they are small studies and do not address all of the comparisons included in this review (355 participants in total). To detect an increase in the proportion of participants who had major bleeding from 1 in 100 to 2 in 100 would require a study containing at least 4634 participants (80% power, 5% significance). PMID:27647489
Description of the second fossil Baltic amber species of Monotomidae (Coleoptera: Cucujoidea).
Bukejs, Andris; Alekseev, Vitalii I
2015-04-10
Based on a specimen from the Upper Eocene Baltic amber (Kaliningrad Region, Russia), Aneurops daugpilensis sp. nov. is described. The new species is similar to the extant A. convergens (Sharp, 1900) and A. championi Sharp, 1900 distributed in North and Central America, but differs in the larger punctation of pronotum, and shorter and sparser setation of the median plaque on ventrite 1. Aneurops daugpilensis sp. nov. is distinguished from Europs insterburgensis Alekseev, 2014 by having a median plaque on ventrite 1, a larger body size, and distinctly sparser punctation of the forebody.
Oom, Rodrigo; Casaca, Rui; Barroca, Rita; Carvalhal, Sara; Santos, Catarina; Abecasis, Nuno
2017-07-14
Centrally inserted central catheter (CICC) insertion is a commonly performed procedure that may give rise to different complications. Despite the suggestion of guidelines to use ultrasound guidance (USG) for vascular access, not all centers use it systematically. The aim of this study is to illustrate the experience with ultrasound in CICC placement at a high-volume oncological center, in a country where the landmark technique is standard. Retrospective analysis of a prospective database was performed on CICC placement under USG in the Central Venous Catheter Unit of Instituto Português de Oncologia de Lisboa Francisco Gentil, from 2012 to 2015. Three thousand five hundred and seventy-two procedures were recorded. From 2728 CICC placements, 1187 (43.5%) were done using USG. The majority of CICC placements were successful without immediate complications (96.1%). In 55 cases (4.6%), more than three attempts were necessary to puncture the vein. Pneumothorax occurred in 5 cases (0.4%) and arterial puncture was registered in 41 cases (3.5%). An increasing use of USG for placing CICCs was planned and observed over the years and, in the last year of the study, 67.3% of the CICC placements were with USG. CICC placement with USG is a safe and effective technique. Despite some resistance that is observed, these results support that it is worth following the guidelines that advocate the use of the USG in the placement of CICC.
Norris, LeAnn B; Kablaoui, Farah; Brilhart, Maggie K; Bookstaver, P Brandon
2017-09-01
Central venous catheter (CVC) use is commonplace in cancer patients. Antimicrobial lock therapy (ALT), the instillation of a concentrated antimicrobial solution into the catheter lumen, is one method for preventing infection among CVCs. This systematic review discusses the effectiveness and safety of prophylactic ALT in cancer patients with CVCs. A literature search was performed using the Medline database and Google Scholar from inception until April 2016. The following terms were used: 'antimicrobial lock solution', 'antibiotic lock solution', 'oncology', 'hematology', 'pediatrics', 'prevention', 'cancer', 'catheter related bloodstream infections', 'central-line associated bloodstream infection' (CLABSI) and 'central venous catheter'. Studies evaluating prophylactic ALT in cancer patients alone were eligible for inclusion. Case reports, case series and in-vitro studies were excluded. In total, 78 articles were identified. Following all exclusions, 13 articles (three adult and 10 pediatric) were selected for evaluation. The most common agents utilized were vancomycin with heparin; ethanol; taurolidine; and minocycline with EDTA. Quality of evidence was moderate to high in adult studies and low to moderate in pediatric studies. Use of ALT decreased the incidence of CLABSI in the majority of studies; however, there were significant differences in definitions of CVC-related infection, dwell times and lock solutions. Lock therapy may be an adjunct in high-risk cancer patients for the prevention of CLABSI; higher quality evidence is needed for specific ALT recommendations. Copyright © 2017 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.
Vasquez, Amber; Zavasky, D; Chow, N A; Gade, L; Zlatanic, E; Elkind, S; Litvintseva, A P; Pappas, P G; Perfect, J R; Revankar, S; Lockhart, S R; Chiller, T; Ackelsberg, J; Vallabhaneni, S
2018-03-05
We report the presentation and management of 17 cases of Exophiala dermatitidis and Rhodotorula mucilaginosa bloodstream infections caused by a compounded parenteral medication at an oncology clinic. Twelve patients were asymptomatic. All central venous catheters were removed and antifungal therapy, primarily voriconazole, was administered to patients. Three patients died.
Childhood Cancer in the Classroom: Information for the School Nurse.
ERIC Educational Resources Information Center
VanDenburgh, Kari
2003-01-01
The school nurse is a resource and support to students, school personnel, and communities with respect to students with cancer. This article discusses: general cancer information and statistics; childhood cancer versus adult cancer; treatments for childhood cancer; and information for school nurses (e.g., central venous catheters in school,…
Circulatory filling pressures during transient microgravity induced by parabolic flight
NASA Technical Reports Server (NTRS)
Latham, Ricky D.; Fanton, John W.; White, C. D.; Vernalis, Mariana N.; Crisman, R. P.; Koenig, S. C.
1993-01-01
Theoretical concepts hold that blood in the gravity dependent portion of the body would relocate to more cephalad compartments under microgravity. The result is an increase in blood volume in the thoraic and cardiac chambers. However, experimental data has been somewhat contradictory and nonconclusive. Early studies of peripheral venous pressure and estimates of central venous pressure (CVP) from these data did not show an increase in CVP under microgravity. However, CVP recorded in human volunteers during a parabolic flight revealed an increase in CVP during the microgravity state. On the STS 40 shuttle mission, a payload specialist wore a fluid line that recorded CVP during the first few hours of orbital insertion. These data revealed decreased CVP. When this CVP catheter was tested during parabolic flight in four subjects, two had increased CVP recordings and two had decreased CVP measurements. In 1991, our laboratory performed parabolic flight studies in several chronic-instrumented baboons. It was again noted that centrally recorded right atrial pressure varied with exposure to microgravity, some animals having an increase, and others a decrease.
[Hemodynamic changes in hypoglycemic shock].
Gutiérrez, C; Piza, R; Chousleb, A; Hidalgo, M A; Ortigosa, J L
1977-01-01
Severe hypoglycemia may be present in seriously ill patients; if it is not corrected opportunely a series of neuroendocrinal mechanisms take place aimed at correcting metabolic alterations. These mechanisms can produce hemodynamic alterations as well. Nine mongrel dogs were studied with continuous registration of: blood pressure, central venous pressure, cardiac frequency, respiratory frequency, electrocardiogram and first derivative (Dp/Dt). Six dogs received crystalline (fast acting) insuline intravenously (group 1). After hemodynamic changes were registered hypoglycemia was corrected with 50 per cent glucose solution. Complementary insuline doses were administered to three dogs (group 2); in this group hypoglycemia was not corrected. In group 1 during hypoglycemia there was an increase in blood pressure, central venous pressure, cardiac frequency, respiratory frequency and Dp/Dt, and changes in QT and T wave on the EKG; these changes were partially reversible after hypoglycemia was corrected. The above mentioned alterations persisted in group 2, breathing became irregular irregular and respiratory arrest supervened. It can be inferred that the hemodynamic response to hypoglycemia is predominantly adrenergic. The role of catecolamines, glucocorticoides, glucagon, insuline, cyclic AMP in metabolic and hemodynamic alterations consecutive to hypoglycemia are discussed.
Ma, Irene W Y; Zalunardo, Nadia; Brindle, Mary E; Hatala, Rose; McLaughlin, Kevin
2015-09-01
Blinded assessments of technical skills using video-recordings may offer more objective assessments than direct observations. This study seeks to compare these two modalities. Two trained assessors independently assessed 18 central venous catheterization performances by direct observation and video-recorded assessments using two tools. Although sound quality was deemed adequate in all videos, portions of the video for wire handling and drape handling were frequently out of view (n = 13, 72% for wire-handling; n = 17, 94% for drape-handling). There were no differences in summary global rating scores, checklist scores, or pass/fail decisions for either modality (p > 0.05). Inter-rater reliability was acceptable for both modalities. Of the 26 discrepancies identified between direct observation and video-recorded assessments, three discrepancies (12%) were due to inattention during video review, while one (4%) discrepancy was due to inattention during direct observation. In conclusion, although scores did not differ between the two assessment modalities, techniques of video-recording may significantly impact individual items of assessments. © The Author(s) 2014.
Substantial harm associated with failure of chronic paediatric central venous access devices.
Ullman, Amanda J; Kleidon, Tricia; Cooke, Marie; Rickard, Claire M
2017-07-06
Central venous access devices (CVADs) form an important component of modern paediatric healthcare, especially for children with chronic health conditions such as cancer or gastrointestinal disorders. However device failure and complications rates are high.Over 2½ years, a child requiring parenteral nutrition and associated vascular access dependency due to 'short gut syndrome' (intestinal failure secondary to gastroschisis and resultant significant bowel resection) had ten CVADs inserted, with ninesubsequently failing. This resulted in multiple anaesthetics, invasive procedures, injuries, vascular depletion, interrupted nutrition, delayed treatment and substantial healthcare costs. A conservative estimate of the institutional costs for each insertion, or rewiring, of her tunnelled CVAD was $A10 253 (2016 Australian dollars).These complications and device failures had significant negative impact on the child and her family. Considering the commonality of conditions requiring prolonged vascular access, these failures also have a significant impact on international health service costs. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Central venous access devices: an investigation of oncology nurses' troubleshooting techniques.
Mason, Tina M; Ferrall, Sheila M; Boyington, Alice R; Reich, Richard R
2014-08-01
Experienced oncology nurses use different troubleshooting techniques for clearing occluded central venous access devices (CVADs) with varying degrees of success. The purpose of this study was to explore troubleshooting techniques used for clearing occluded CVADs by experienced oncology RNs and identify the perceived effectiveness of each technique. An invitation for a web-based survey was sent to select RN members of the Oncology Nursing Society. All nurses (N = 224) reported asking patients to raise and/or move their arm. Most nurses asked patients to lie down, cough, and take deep breaths. Respondents considered instilling a thrombolytic agent to be the most effective technique. No associations were found between techniques and respondents' years in oncology nursing, work setting, certification, or academic degree. The findings contribute to knowledge about care of patients with occluded devices and will help formulate direction for additional investigation of CVADs. Establishing the appropriateness of practice-related troubleshooting techniques may eliminate unnecessary steps and save nursing time. Educating nurses on the topic will also help reduce techniques that are not expected to yield results or are contraindicated.
Agrobacterium radiobacter bacteremia in a patient with chronic obstructive pulmonary disease.
Yu, W L; Wang, D Y; Lin, C W
1997-08-01
Agrobacterium radiobacter is a gram-negative bacillus, which is recognized as an emerging opportunistic human pathogen. To our knowledge, there have been only 25 cases of A. radiobacter bacteremia reported. In most of these, A. radiobacter was associated with long-term indwelling plastic central venous catheters. We describe a 78-year-old man who had a history of chronic obstructive pulmonary disease with long-term use of a corticosteroid. He was admitted to the China Medical College Hospital with pneumonia caused by Serratia marcescens. His general condition gradually improved after initiation of appropriate treatment. Unfortunately, he developed A. radiobacter bacteremia while hospitalized in the medical intensive care unit. With the onset of this infection, the patient had a high fever, leukocytosis, raised C-reactive protein level, and positive blood cultures for A. radiobacter. A central venous catheter-related infection was suspected because of redness and localized tenderness at the catheter site. The patient gradually recovered after removal of the catheter and appropriate antimicrobial treatment with latamoxef 1.5 g intravenously every 8 hours for 10 days.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aranguren, Xabier L., E-mail: xabier.lopezaranguren@med.kuleuven.be; Beerens, Manu, E-mail: manu.beerens@med.kuleuven.be; Vandevelde, Wouter, E-mail: woutervandevelde@gmail.com
Highlights: {yields} COUP-TFII deficiency in zebrafish affects arterio-venous EC specification. {yields} COUP-TFII is indispensable for lymphatic development in zebrafish. {yields} COUP-TFII knockdown in Xenopus disrupts lymphatic EC differentiation and migration. {yields} COUP-TFII's role in EC fate decisions is evolutionary conserved. -- Abstract: Transcription factors play a central role in cell fate determination. Gene targeting in mice revealed that Chicken Ovalbumin Upstream Promoter-Transcription Factor II (COUP-TFII, also known as Nuclear Receptor 2F2 or NR2F2) induces a venous phenotype in endothelial cells (ECs). More recently, NR2F2 was shown to be required for initiating the expression of Prox1, responsible for lymphatic commitment ofmore » venous ECs. Small animal models like zebrafish embryos and Xenopus laevis tadpoles have been very useful to elucidate mechanisms of (lymph) vascular development. Therefore, the role of NR2F2 in (lymph) vascular development was studied by eliminating its expression in these models. Like in mice, absence of NR2F2 in zebrafish resulted in distinct vascular defects including loss of venous marker expression, major trunk vessel fusion and vascular leakage. Both in zebrafish and Xenopus the development of the main lymphatic structures was severely hampered. NR2F2 knockdown significantly decreased prox1 expression in zebrafish ECs and the same manipulation affected lymphatic (L)EC commitment, migration and function in Xenopus tadpoles. Therefore, the role of NR2F2 in EC fate determination is evolutionary conserved.« less
Samadi, Mahmood; Malaki, Majid; Ghaffari, Shamsi; Golshan Khalili, Roza
2012-01-01
Low Cardiac Output Syndrome (LCOS) contributes to postoperative morbidity and mortality. This article tries to find a predictive factor to interpret outcome after cardiac operation. In a cross-sectional study, 100 children with congenital heart disease undergoing cardiovascular surgery with cardiopulmonary bypass (CPB) without significant left-to-right shunt were selected. Arterial and central venous oxygen saturation values were measured via blood samples simultaneously obtained in 6-hr intervals for a total of 24-hr during postoperative period at hours 0, 6, 12, 18, and 24. Postoperative ventilation support (intubation period) and cardiovascular support were also obtained from the hospital records. Statistical analysis was later performed comparing the arterial-mixed venous oxygen saturation differences and durations of required ventilatory and cardiovascular support, both for the complicated and non-complicated patient groups. The data was processed with correlation Pearson and Mann-Whitney U tests in SPSS 15 software, P less than 0.05 was significant. Mortality following cardiac operation is 6% and complications may happen in 45% of the cases. The highest Arterial-mixed venous oxygen saturation difference occurred immediately post operation (up to 57%). These measures were high up to 18 hours in complicated and non-complicated groups (36% vs. 31% ; P< 0.05). This factor cannot predict prolongation of intubation period in patients (P > 0.05). Arterial-mixed venous oxygen saturation difference may be high as much as 57% or as low as 23%.These different measures, being higher up to 18 hours in complicated to non-complicated groups after 18 hours, can be related to tissue ischemia during surgery and cannot be discriminative.
Keilani, C; Halalchi, A; Wakpi Djeugue, D; Regis, A; Abada, S
2016-12-01
In the present study, we examined retinal vascular oxygen saturation in patients with retinal vein occlusion (RVO), high blood pressure (HBP) and dyslipidemia, before and during intravitreal vascular endothelial growth factor (VEGF) injection (ranibizumab). We retrospectively reviewed the medical records of six patients with visual acuity (VA) reduced by macular edema (ME) secondary to RVO with HBP and dyslipidemia, who underwent intravitreal anti-VEGF injection between October 2014 and February 2015 in the department of ophthalmology of François-Quesnay Hospital at Mantes-la-Jolie (France). The main inclusion criterion was the presence of RVO with ME and decreased VA. The primary endpoint was improvement of retinal venous oxygen saturation in patients with RVO before and 3 months after intravitreal ranibizumab injection. Secondary outcomes were improvement of retinal arterial oxygen saturation, improvement of best-corrected visual acuity (BCVA) on the Early Treatment Diabetic Retinopathy Study (ETDRS) scale, regression of ME measured by the central macular thickness (CMT) in nm and studying the correlation between blood pressure (BP) and retinal venous oxygen saturation before and after ranibizumab. Six eyes of six patients were included. Before treatment, the mean (standard deviation [SD]) of the retinal venous saturation (%) was 38.1±14.2. Three months after the injections, the mean (SD) of the retinal venous saturation (%) increased statistically significantly 49.2±11 (P=0.03). In this study, retinal venous oxygen saturation in patients with RVO, HBP and dyslipidemia was partially normalized during intravitreal ranibizumab treatment. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Patients' perceptions and responses to procedural pain: results from Thunder Project II.
Puntillo, K A; White, C; Morris, A B; Perdue, S T; Stanik-Hutt, J; Thompson, C L; Wild, L R
2001-07-01
Little is known about the painfulness of procedures commonly performed in acute and critical care settings. To describe pain associated with turning, wound drain removal, tracheal suctioning, femoral catheter removal, placement of a central venous catheter, and nonburn wound dressing change and frequency of use of analgesics during procedures. A comparative, descriptive design was used. Numeric rating scales were used to measure pain intensity and procedural distress; word lists, to measure pain quality. Data were obtained from 6201 patients: 176 younger than 18 years and 5957 adults. Mean pain intensity scores for turning and tracheal suctioning were 2.80 and 3.00, respectively (scale, 0-5), for 4- to 7-year-olds and 52.0 and 28.1 (scale, 0-100) for 8- to 12-year-olds. For adolescents, mean pain intensity scores for wound dressing change, turning, tracheal suctioning, and wound drain removal were 5 to 7 (scale, 0-10); mean procedural distress scores were 4.83 to 6.00 (scale, 0-10). In adults, mean pain intensity scores for all procedures were 2.65 to 4.93 (scale, 0-10); mean procedural distress scores were 1.89 to 3.47 (scale, 0-10). The most painful and distressing procedures were turning for adults and wound care for adolescents. Procedural pain was often described as sharp, stinging, stabbing, shooting, and awful. Less than 20% of patients received opiates before procedures. Procedural pain varies considerably and is procedure specific. Because procedures are performed so often, more individualized attention to preparation for and control of procedural pain is warranted.
Extravasation injuries in adults.
Al-Benna, S; O'Boyle, C; Holley, J
2013-01-01
Insertion of an intravascular catheter is one of the most common invasive procedures in hospitals worldwide. These intravascular lines are crucial in resuscitation, allow vital medication to be administered, and can be used to monitor the patients' real-time vital parameters. There is, however, growing recognition of potential risks to life and limb associated with their use. Medical literature is now replete with isolated case reports of complications succinctly described by Garden and Laussen (2004) as "An unending supply of "unusual" complications from central venous catheters." This paper reviews complications of venous and arterial catheters and discusses treatment approaches and methods to prevent complications, based on current evidence and endeavours to provide information and guidance that will enable practitioners to prevent, recognise, and successfully treat extravasation injuries in adults.
Two Cases of Bacteremia Due to Roseomonas mucosa.
Kim, Yu Kyung; Moon, Jung Suk; Song, Kyung Eun; Lee, Won Kil
2016-07-01
Roseomonas is a genus of pink-pigmented nonfermentative bacilli. These slow-growing, gram-negative cocobacilli form pink-colored colonies on sheep blood agar. They differ from other pink-pigmented nonfermenters, including Methylobacterium, in morphology, biochemical characteristics, and DNA sequence. Roseomonas strains are rarely isolated in clinical laboratories; therefore, we report two cases in order to improve our ability to identify these pathogens. We isolated two strains of Roseomonas mucosa from the venous blood cultures of two patients, an 84-yr-old woman with common bile duct obstruction and a 17-yr-old male with acute myeloid leukemia who had an indwelling central-venous catheter for chemotherapy. The isolated strains were confirmed as R. mucosa by 16S rRNA sequencing.
Two Cases of Bacteremia Due to Roseomonas mucosa
Kim, Yu Kyung; Moon, Jung Suk; Song, Kyung Eun
2016-01-01
Roseomonas is a genus of pink-pigmented nonfermentative bacilli. These slow-growing, gram-negative cocobacilli form pink-colored colonies on sheep blood agar. They differ from other pink-pigmented nonfermenters, including Methylobacterium, in morphology, biochemical characteristics, and DNA sequence. Roseomonas strains are rarely isolated in clinical laboratories; therefore, we report two cases in order to improve our ability to identify these pathogens. We isolated two strains of Roseomonas mucosa from the venous blood cultures of two patients, an 84-yr-old woman with common bile duct obstruction and a 17-yr-old male with acute myeloid leukemia who had an indwelling central-venous catheter for chemotherapy. The isolated strains were confirmed as R. mucosa by 16S rRNA sequencing. PMID:27139611
Ahn, J H; Kim, I S; Yang, J H; Lee, I G; Seo, D H; Kim, S P
2017-02-01
The lower superior vena cava (SVC), near its junction with the right atrium (RA), is considered the ideal location for the central venous catheter tip to ensure proper function and prevent injuries. We determined catheter insertion depth with a new formula using the sternoclavicular joint and the carina as radiological landmarks, with a 1.5 cm safety margin. The accuracy of tip positioning with the radiological landmark-based technique (R) and Peres' formula (P) was compared using transoesophageal echocardiography. Real-time ultrasound-guided central venous catheter insertion was done through the right internal jugular or subclavian vein. Patients were randomly assigned to either the P group (n=93) or the R group (n=95). Optimal catheter tip position was considered to be within 2 cm above and 1 cm below the RA-SVC junction. Catheter tip position, abutment, angle to the vascular wall, and flow stream were evaluated on a bicaval view. The distance from the skin insertion point to the RA-SVC junction and determined depth of catheter insertion were more strongly correlated in the R group [17.4 (1.2) and 16.7 (1.5) cm; r=0.821, P<0.001] than in the P group [17.3 (1.2) and 16.4 (1.1) cm; r=0.517, P<0.001], with z=3.96 (P<0.001). More tips were correctly positioned in the R group than in the P group (74 vs 93%, P=0.001). Abutment, tip angle to the lateral wall >40°, and disrupted flow stream were comparable. Catheter tip position was more accurate with a radiological landmark-based technique than with Peres' formula. Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp KCT0001937. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lucas, Rebekah A. I.; Pearson, James; Schlader, Zachary J.; Crandall, Craig G.
2016-01-01
This study tested the hypothesis that baroreceptor unloading during passive hyperthermia contributes to increases in ventilation and decreases in end-tidal partial pressure of carbon dioxide (PET,CO2) during that exposure. Two protocols were performed, in which healthy subjects underwent passive hyperthermia (increasing intestinal temperature by ~1.8°C) to cause a sustained increase in ventilation and reduction in PET,CO2. Upon attaining hyperthermic hyperventilation, in protocol 1 (n = 10; three females) a bolus (19 ± 2 ml kg−1) of warm (~38°C) isotonic saline was rapidly (5–10 min) infused intravenously to restore reductions in central venous pressure, whereas in protocol 2 (n = 11; five females) phenylephrine was infused intravenously (60–120 μg min−1) to return mean arterial pressure to normothermic levels. In protocol 1, hyperthermia increased ventilation (by 2.2 ± 1.7 l min−1, P < 0.01), while reducing PET,CO2 (by 4 ± 3 mmHg, P = 0.04) and central venous pressure (by 5 ± 1 mmHg, P <0.01). Saline infusion increased central venous pressure by 5 ± 1 mmHg (P < 0.01), restoring it to normothermic values, but did not change ventilation or PET,CO2 (P > 0.05). In protocol 2, hyperthermia increased ventilation (by 5.0 ± 2.7l min−1, P <0.01) and reduced PET ,CO2 (by 5 ± 2 mmHg, P < 0.01) and mean arterial pressure (by 9 ± 7 mmHg, P <0.01). Phenylephrine infusion increased mean arterial pressure by 12 ± 3 mmHg (P < 0.01), restoring it to normothermic values, but did not change ventilation or PET,CO2 (P > 0.05). The absence of a reduction in ventilation upon reloading the cardiopulmonary and arterial baroreceptors to pre-hyperthermic levels indicates that baroreceptor unloading with hyperthermia is unlikely to contribute to hyperthermic hyperventilation in humans. PMID:26299270
Enokizono, Mikako; Sato, Noriko; Morikawa, Minoru; Kimura, Yukio; Sugiyama, Atsuhiko; Maekawa, Tomoko; Sone, Daichi; Takewaki, Daiki; Okamoto, Tomoko; Takahashi, Yuji; Horie, Nobutaka; Matsuo, Takayuki
2017-08-15
A dural arteriovenous fistula (DAVF) with spinal perimedullary venous drainage can cause progressive myelopathy, and it is sometimes incorrectly diagnosed as another spinal cord disease. Here we report the cases of three individuals with a DAVF (one craniocervical junction DAVF and two tentorial DAVFs) with progressive myelopathy showing unique magnetic resonance (MR) imaging findings. MR T2*WI or susceptibility-weighted imaging (SWI) demonstrated symmetrical dark signal intensity lesions predominantly in the dorsal aspect of medulla and the central gray matter of cervical spinal cord that showed the "black butterfly" silhouette. Cerebral angiography revealed DAVFs draining into anterior and posterior spinal veins. Dark signals on T2*WI and SWI were presumed to be hemorrhages, which were probably caused by prolonged venous congestion. Identifying this "black butterfly" sign can facilitate the diagnosis of DAVF, differentiating DAVF from other spinal cord diseases such as demyelinating lesions and neoplasms. Copyright © 2017 Elsevier B.V. All rights reserved.
Effects of acute hypoxia on cardiopulmonary responses to head-down tilt
NASA Technical Reports Server (NTRS)
Loeppky, J. A.; Luft, U. C.; Scotto, P.; Chick, T. W.
1990-01-01
Six male subjects were exposed on two separate occasions to simulated microgravity with 28 deg head-down tilt (HD) for 1 h with baseline followed by recovery at + 17 deg head-up. Pulmonary ventilation, gas exchange, spirometry, and central and cerebral blood flow characteristics were compared while breathing ambient air and reduced F(I)O2 equivalent to 14,828 ft. With hypoxia (HY), the increased tidal volume served to attenuate the drop in arterial saturation by reducing deadspace ventilation. Arterial and mixed venous PO2, values, estimated from peripheral venous samples and cardiac output (CO), were both maintained during HD in HY. Mixed venous PO2 was elevated by an increase in CO associated with a reduction in systemic resistance. Changes in spirometric indices during HD were not accentuated by HY, making the presence of interstitial edema unlikely. Cerebral flow and resistance showed minor reductions with HD. Tissue oxygenation and cardiopulmonary function were not notably effected by HD during HY, but a combination of these two stressors may predispose subjects to subsequent orthostatic intolerance during initial recovery.
Cardiovascular physiology - Effects of microgravity
NASA Technical Reports Server (NTRS)
Convertino, V.; Hoffler, G. W.
1992-01-01
Experiments during spaceflight and its groundbase analog, bedrest, provide consistent data which demonstrate that numerous changes in cardiovascular function occur as part of the physiological adaptation process to the microgravity environment. These include elevated heart rate and venous compliance, lowered blood volume, central venous pressure and stroke volume, and attenuated autonomic reflex functions. Although most of these adaptations are not functionally apparent during microgravity exposure, they manifest themselves during the return to the gravitational challenge of earth's terrestrial environment as orthostatic hypotension and instability, a condition which could compromise safety, health and productivity. Development and application of effective and efficient countermeasures such as saline "loading," intermittent venous pooling, pharmacological treatments, and exercise have become primary emphases of the space life sciences research effort with only limited success. Successful development of countermeasures will require knowledge of the physiological mechanisms underlying cardiovascular adaptation to microgravity which can be obtained only through controlled, parallel groundbased research to complement carefully designed flight experiments. Continued research will provide benefits for both space and clinical applications as well as enhance the basic understanding of cardiovascular homeostasis in humans.
Evaluation of risk factors for thrombophilia in patients with cerebral venous thrombosis.
Yokuş, Osman; Şahin Balçık, Özlem; Albayrak, Murat; Ceran, Funda; Dağdaş, Simten; Yılmaz, Mesude; Özet, Gülsüm
2010-09-05
The increased risk for thrombosis is known as hypercoagulability or thrombophilia. In our study, we aimed to compare the frequency of the identified defects for thrombophilia in patients with central venous thrombosis and under the age of 50 years, with the findings in the current literature. Forty-three patients (16-50 years old) were retrospectively evaluated. Thrombophilia investigation included determinations of protein C, protein S, antithrombin, and activated protein C resistance, factor V Leiden (FVL), prothrombin 20210A (PT 20210) and methylene tetrahydrofolate reductase (MTHFR) C677T mutations, antiphospholipid antibodies (APA), factor VIII levels, and homocysteine levels. We detected a single thrombophilic defect in 67.4%, two defects in 27.9% and three defects in 4.7% of our patients. The most common thrombophilic defect was mutation in the MTHFR gene (41.8%), and this was followed by the FVL mutation (34.9%). Since the prevalence of individual thrombophilic defects varies in each population, ethnic group and geographical location, screening for thrombophilic defects in patients presenting with cerebral venous thrombosis should primarily investigate the most frequent thrombophilia risk factors.
Should nurses be trained to use ultrasound for intravenous access to patients with difficult veins?
Smith, Claire
2018-06-14
Peripheral venous access is the most common invasive procedure performed on patients in the UK and is traditionally the responsibility of nursing staff. In an emergency, intravenous therapy can be lifesaving. Approximately 11% of adults have difficult venous access and are often subjected to repeated failed attempts, resulting in delayed diagnosis and treatment. Eventually, rescue methods are used by a doctor, but this increases demand on their time and the workflow of emergency departments. This article explores whether training nurses to obtain venous access using ultrasound would have a positive effect on doctors' workload and benefit adult patients with difficult veins. Research indicates that nurses can successfully use ultrasound to reduce the number of attempts, time to access and patient discomfort, and can prevent the insertion of unnecessary central lines. Ultrasound training programmes for nurses demonstrate benefits for patients and clinicians. © 2018 RCN Publishing Company Ltd. All rights reserved. Not to be copied, transmitted or recorded in any way, in whole or part, without prior permission of the publishers.
Thrombotic complications of implanted central venous access devices: prospective evaluation.
Labourey, Jean-Luc; Lacroix, Philippe; Genet, Dominique; Gobeaux, François; Martin, Jean; Venat-Bouvet, Laurence; Lavau-Denes, Sandrine; Maubon, Antoine; Tubiana-Mathieu, Nicole
2004-05-01
Implanted venous access devices (IVAD) are routinely used in oncologic patients. Thrombotic complication is a source of morbidity. During one year 246 patients with different solid neoplastic diseases received IVAD for chemotherapy administration. Two hundred forty-nine IVAD were placed percutaneously or by surgical cutdown. IVAD were flushed immediately after implantation with 3-5 mL of heparinized saline (100 U/mL). No monthly flush was required. A prospective evaluation of thrombotic complications was realised. in event of catheter dysfunction and/or clinical symptoms of phlebitis, a catheter opacification and/or a Doppler ultrasonography were performed. Twenty-three catheter dysfunctions were noted, corresponding to 13 catheter occlusions. Twelve patients presented clinical symptoms of phlebitis. Eleven venous thrombosis were diagnosed in this group; 10 by echo-Doppler and one by scanography. A unvaried statistic analysis using Fisher's test was performed to detect risk factors. Two factors were identified: the position of catheter tip above T4 (p < 0.001) and mediastinal or cervical lymph nodes larger than 6 cm (p < 0.001). The first increased the risk of catheter occlusion and the second increased the risk of phlebitis.
Zhao, Liqin; Winklhofer, Sebastian; Yang, Zhenghan; Wang, Keyang; He, Wen
2016-03-01
The aim of this article was to study the influence of different adaptive statistical iterative reconstruction (ASIR) percentages on the image quality of dual-energy computed tomography (DECT) portal venography in portal hypertension patients. DECT scans of 40 patients with cirrhosis (mean age, 56 years) at the portal venous phase were retrospectively analyzed. Monochromatic images at 60 and 70 keV were reconstructed with four ASIR percentages: 0%, 30%, 50%, and 70%. Computed tomography (CT) numbers of the portal veins (PVs), liver parenchyma, and subcutaneous fat tissue in the abdomen were measured. The standard deviation from the region of interest of the liver parenchyma was interpreted as the objective image noise (IN). The contrast-noise ratio (CNR) between PV and liver parenchyma was calculated. The diagnostic acceptability (DA) and sharpness of PV margins were obtained using a 5-point score. The IN, CNR, DA, and sharpness of PV were compared among the eight groups with different keV + ASIR level combinations. The IN, CNR, DA, and sharpness of PV of different keV + ASIR groups were all statistically different (P < 0.05). In the eight groups, the best and worst CNR were obtained in the 60 keV + 70% ASIR and 70 keV + 0% ASIR (filtered back-projection [FBP]) combination, respectively, whereas the largest and smallest objective IN were obtained in the 60 keV + 0% ASIR (FBP) and 70 keV + 70% combination. The highest DA and sharpness values of PV were obtained at 50% ASIR for 60 keV. An optimal ASIR percentage (50%) combined with an appropriate monochromatic energy level (60 keV) provides the highest DA in portal venography imaging, whereas for the higher monochromatic energy (70 keV) images, 30% ASIR provides the highest image quality, with less IN than 60 keV with 50% ASIR. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Furlan, R.; Porta, A.; Costa, F.; Tank, J.; Baker, L.; Schiavi, R.; Robertson, D.; Malliani, A.; Mosqueda-Garcia, R.
2000-01-01
BACKGROUND: We tested the hypothesis that a common oscillatory pattern might characterize the rhythmic discharge of muscle sympathetic nerve activity (MSNA) and the spontaneous variability of heart rate and systolic arterial pressure (SAP) during a physiological increase of sympathetic activity induced by the head-up tilt maneuver. METHODS AND RESULTS: Ten healthy subjects underwent continuous recordings of ECG, intra-arterial pressure, respiratory activity, central venous pressure, and MSNA, both in the recumbent position and during 75 degrees head-up tilt. Venous samplings for catecholamine assessment were obtained at rest and during the fifth minute of tilt. Spectrum and cross-spectrum analyses of R-R interval, SAP, and MSNA variabilities and of respiratory activity provided the low (LF, 0.1 Hz) and high frequency (HF, 0.27 Hz) rhythmic components of each signal and assessed their linear relationships. Compared with the recumbent position, tilt reduced central venous pressure, but blood pressure was unchanged. Heart rate, MSNA, and plasma epinephrine and norepinephrine levels increased, suggesting a marked enhancement of overall sympathetic activity. During tilt, LF(MSNA) increased compared with the level in the supine position; this mirrored similar changes observed in the LF components of R-R interval and SAP variabilities. The increase of LF(MSNA) was proportional to the amount of the sympathetic discharge. The coupling between LF components of MSNA and R-R interval and SAP variabilities was enhanced during tilt compared with rest. CONCLUSIONS: During the sympathetic activation induced by tilt, a similar oscillatory pattern based on an increased LF rhythmicity characterized the spontaneous variability of neural sympathetic discharge, R-R interval, and arterial pressure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akahane, Akio, E-mail: a.akahane@gmail.com; Sone, Miyuki; Ehara, Shigeru
2011-12-15
Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access-the subclavian vein and arm vein-in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achievedmore » in all patients. The median follow-up period was 94 (range, 1-891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.« less
A mixed-reality part-task trainer for subclavian venous access.
Robinson, Albert R; Gravenstein, Nikolaus; Cooper, Lou Ann; Lizdas, David; Luria, Isaac; Lampotang, Samsun
2014-02-01
Mixed-reality (MR) procedural simulators combine virtual and physical components and visualization software that can be used for debriefing and offer an alternative to learn subclavian central venous access (SCVA). We present a SCVA MR simulator, a part-task trainer, which can assist in the training of medical personnel. Sixty-five participants were involved in the following: (1) a simulation trial 1; (2) a teaching intervention followed by trial 2 (with the simulator's visualization software); and (3) trial 3, a final simulation assessment. The main test parameters were time to complete SCVA and the SCVA score, a composite of efficiency and safety metrics generated by the simulator's scoring algorithm. Residents and faculty completed questionnaires presimulation and postsimulation that assessed their confidence in obtaining access and learner satisfaction questions, for example, realism of the simulator. The average SCVA score was improved by 24.5 (n=65). Repeated-measures analysis of variance showed significant reductions in average time (F=31.94, P<0.0001), number of attempts (F=10.56, P<0.0001), and score (F=18.59, P<0.0001). After the teaching intervention and practice with the MR simulator, the results no longer showed a difference in performance between the faculty and residents. On a 5-point scale (5=strongly agree), participants agreed that the SCVA simulator was realistic (M=4.3) and strongly agreed that it should be used as an educational tool (M=4.9). An SCVA mixed simulator offers a realistic representation of subclavian central venous access and offers new debriefing capabilities.
Secola, Rita; Azen, Colleen; Lewis, Mary Ann; Pike, Nancy; Needleman, Jack; Sposto, Richard; Doering, Lynn
2012-01-01
Treatment for most children with cancer includes the use of a central venous catheter (CVC). CVCs provide reliable venous access for delivery of chemotherapy and supportive care. This advantage is mitigated by an increased risk of bloodstream infections (BSIs). Despite the ubiquitous use of CVCs, few prospective studies have been conducted to address infection prevention strategies in pediatric oncology patients. Prospective, crossover pilot study of a CVC team intervention versus standard care. Two inpatient oncology units in a metropolitan children's hospital. A total of 41 patients/135 admissions for the experimental unit (EU) and 41/129 admissions for the control unit (CU). Patients received a CVC blood draw bundle procedure by a CVC registered nurse (RN) team member (experimental intervention: EU) for 6 months and by the assigned bedside RN (standard care: CU) for 6 months. Feasibility of implementing a CVC RN team; a significant difference in CVC-related BSIs between the team intervention versus standard care and risk factors associated in the development of CVC-related BSIs were determined. There were 7 CVC-related BSIs/1238 catheter days in the EU group (5.7/1000 catheter days) versus 3 CVC-related BSIs/1419 catheter days in the CU group (2.1/1000 catheter days; P = .97). Selected risk factors were not significantly associated with the development of a CVC-related BSI. A CVC team in the care of pediatric oncology patients is feasible; however, a larger cohort will be required to adequately determine the effectiveness of the team reducing CVC-related BSIs.
Complications of Peripherally Inserted Central Venous Catheters: A Retrospective Cohort Study
Jose Amo-Setién, Francisco; Herrero-Montes, Manuel; Olavarría-Beivíde, Encarnación; Rodríguez-Rodríguez, Mercedes; Torres-Manrique, Blanca; Rodríguez-de la Vega, Carlos; Caso-Álvarez, Vanesa; González-Parralo, Laura
2016-01-01
Background and Aim The use of venous catheters is a widespread practice, especially in oncological and oncohematological units. The objective of this study was to evaluate the complications associated with peripherally inserted central catheters (PICCs) in a cohort of patients. Materials and Methods In this retrospective cohort study, we included all patient carrying PICCs (n = 603) inserted at our institute between October 2010 and December 2013. The main variables collected were medical diagnosis, catheter care, location, duration of catheterization, reasons for catheter removal, complications, and nursing care. Complications were classified as infection, thrombosis, phlebitis, migration, edema, and/or ecchymosis. Results All patients were treated according to the same “nursing care” protocol. The incidence rate of complications was two cases per 1000 days of catheter duration. The most relevant complications were infection and thrombosis, both with an incidence of 0.17 cases per 1000 days of the total catheterization period. The total average duration of catheterization was 170 days [SD 6.06]. Additionally to “end of treatment” (48.42%) and “exitus”, (22.53%) the most frequent cause of removal was migration (displacement towards the exterior) of the catheter (5.80%). Conclusions PICCs are safe devices that allow the administration of long-term treatment and preserve the integrity of the venous system of the patient. Proper care of the catheter is very important to improve the quality life of patients with oncologic and hematologic conditions. Therefore, correct training of professionals and patients as well as following the latest scientific recommendations are particularly relevant. PMID:27588946
An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desai, Shamit S., E-mail: shamit.desai@northwestern.edu; Konanur, Meghana; Foltz, Gretchen
PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared andmore » externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.« less
ARIBAŞ, BILGIN KADRI; ARDA, KEMAL; ARIBAŞ, ÖZGE; ÇILEDAĞ, NAZAN; YOLOĞLU, ZEYNEL; AKTAŞ, ELIF; SEBER, TURGUT; KAVAK, ŞEYHMUS; COŞAR, YUSUF; KAYGUSUZ, HIDIR; TEKIN, EKREM
2012-01-01
The purpose of the present study was to examine whether patency times, including complications of subcutaneous venous chest port insertion using ultrasonography (US) guidance, differ between jugular and subclavian venous access. Between December 2008 and July 2010, subcutaneous venous chest ports were placed in 347 patients by an experienced team. All single-lumen port catheters were placed into jugular and subclavian veins under US and fluoroscopy guidance. Patency times and complication rates of ports via these routes were compared and the variables were age, gender, access, site of malignancy and coagulation parameters. The success of the jugular and subclavian groups was compared by univariate Kaplan-Meier survival analysis and the multivariable Cox regression test. A total of 15 patients underwent port removal due to complications. As a rate per 100 catheter days, ports were explanted in 7 (0.0092) due to thrombosis, 4 (0.0053) for catheter malposition, one each (0.0013) of port reservoir flip-over, bleeding, port pocket infection, skin necrosis and incision dehiscence, for a total of 15 patients (0.0197). Patency times were not different in the jugular and subclavian veins. Factors were not significant, with the exception of platelet count. There was no significant difference in patency times, including complications, between jugular vein access and subclavian vein access using US. This should be considered when selecting the access method. PMID:23170125
Ramirez, Alexies; Gentlesk, Philip J; Peele, Mark E; Eckart, Robert E
2012-07-01
Device therapy is becoming common in those patients with renal insufficiency. Coexisting need for arteriovenous (AV) fistula placement is often contemplated relative to device placement. We describe the excimer laser lead extraction of a malfunctioning chronic atrial pacemaker lead ipsilateral to an AV fistula.
Research and Development of Advanced Life Support Equipment.
1999-02-01
kg.) were catheterized f or measurement of left ventricular pressure (LVP), right ventricular pressure (RVP), mean aortic pressure (MAP), central ...Orientation Laboratory Venous Gas Emboli Variable Profile Breathing Simulator Wingate Anaerobic Test Weapons System Trainer World Wide Web... history screening of the potential subjects was conducted to eliminate those individuals who have known health conditions/ histories which would
Dialysis catheter associated cardiac tamponade: quick diagnosis by extemporaneous echocardiography.
Ervo, R; Angeletti, S; Turrini Dertenois, L; Cavatorta, F
2008-01-01
We report a case of pericardial tamponade associated with over the wire exchange of a central venous catheter (CVC) for hemodialysis (HD). The complication was quickly diagnosed due to an extemporaneous echocardiogram with a linear probe, before other laboratory and radiologic tests could detect it. The described approach allowed a suitable therapy with a positive result.
A Case of Neuro-Behcet’s Disease Presenting with Central Neurogenic Hyperventilation
Alkhachroum, Ayham M.; Saeed, Saba; Kaur, Jaspreet; Shams, Tanzila; De Georgia, Michael A.
2016-01-01
Patient: Female, 46 Final Diagnosis: Central hyperventilation Symptoms: Hyperventilation Medication: — Clinical Procedure: None Specialty: Neurology Objective: Unusual clinical course Background: Behcet’s disease is a chronic inflammatory disorder usually characterized by the triad of oral ulcers, genital ulcers, and uveitis. Central to the pathogenesis of Behcet’s disease is an autoimmune vasculitis. Neurological involvement, so called “Neuro-Behcet’s disease”, occurs in 10–20% of patients, usually from a meningoencephalitis or venous thrombosis. Case Report: We report the case of a 46-year-old patient with Neuro-Behcet’s disease who presented with central neurogenic hyperventilation as a result of brainstem involvement from venulitis. Conclusions: To the best of our knowledge, central neurogenic hyperventilation has not previously been described in a patient with Neuro-Behcet’s disease. PMID:26965646
Evaluation of an Impedance Threshold Device as a VIIP Countermeasure
NASA Technical Reports Server (NTRS)
Ebert, D.; Macias, B.; Garcia, K.; Stenger, M.; Hargens, A.; Johnston, S.
2016-01-01
Visual Impairment /Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.
Evaluation of an Impedance Threshold Device as a VIIP Countermeasure
NASA Technical Reports Server (NTRS)
Ebert, Douglas; Macias, Brandon; Sargsyan, Ashot; Garcia, Kathleen; Stenger, Michael; Hargens, Alan; Johnston, Smith; Kemp, David; Danielson, Richard
2016-01-01
Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.
Methods to decrease blood loss during liver resection: a network meta-analysis.
Moggia, Elisabetta; Rouse, Benjamin; Simillis, Constantinos; Li, Tianjing; Vaughan, Jessica; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2016-10-31
Liver resection is a major surgery with significant mortality and morbidity. Specialists have tested various methods in attempts to limit blood loss, transfusion requirements, and morbidity during elective liver resection. These methods include different approaches (anterior versus conventional approach), use of autologous blood donation, cardiopulmonary interventions such as hypoventilation, low central venous pressure, different methods of parenchymal transection, different methods of management of the raw surface of the liver, different methods of vascular occlusion, and different pharmacological interventions. A surgeon typically uses only one of the methods from each of these seven categories. The optimal method to decrease blood loss and transfusion requirements in people undergoing liver resection is unknown. To assess the effects of different interventions for decreasing blood loss and blood transfusion requirements during elective liver resection. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, and Science Citation Index Expanded to September 2015 to identify randomised clinical trials. We also searched trial registers and handsearched the references lists of identified trials. We included only randomised clinical trials (irrespective of language, blinding, or publication status) comparing different methods of decreasing blood loss and blood transfusion requirements in people undergoing liver resection. Two review authors independently identified trials and collected data. We assessed the risk of bias using Cochrane domains. We conducted a Bayesian network meta-analysis using the Markov chain Monte Carlo method in WinBUGS 1.4, following the guidelines of the National Institute for Health and Care Excellence Decision Support Unit guidance documents. We calculated the odds ratios (OR) with 95% credible intervals (CrI) for the binary outcomes, mean differences (MD) with 95% CrI for continuous outcomes, and rate ratios with 95% CrI for count outcomes, using a fixed-effect model or random-effects model according to model-fit. We assessed the evidence with GRADE. We identified 67 randomised clinical trials involving a total of 6197 participants. All the trials were at high risk of bias. A total of 5771 participants from 64 trials provided data for one or more outcomes included in this review. There was no evidence of differences in most of the comparisons, and where there was, these differences were in single trials, mostly of small sample size. We summarise only the evidence that was available in more than one trial below. Of the primary outcomes, the only one with evidence of a difference from more than one trial under the pair-wise comparison was in the number of adverse events (complications), which was higher with radiofrequency dissecting sealer than with the clamp-crush method (rate ratio 1.85, 95% CrI 1.07 to 3.26; 250 participants; 3 studies; very low-quality evidence). Among the secondary outcomes, the only differences we found from more than one trial under the pair-wise comparison were the following: blood transfusion (proportion) was higher in the low central venous pressure group than in the acute normovolemic haemodilution plus low central venous pressure group (OR 3.19, 95% CrI 1.56 to 6.95; 208 participants; 2 studies; low-quality evidence); blood transfusion quantity (red blood cells) was lower in the fibrin sealant group than in the control (MD -0.53 units, 95% CrI -1.00 to -0.07; 122 participants; 2; very low-quality evidence); blood transfusion quantity (fresh frozen plasma) was higher in the oxidised cellulose group than in the fibrin sealant group (MD 0.53 units, 95% CrI 0.36 to 0.71; 80 participants; 2 studies; very low-quality evidence); blood loss (MD -0.34 L, 95% CrI -0.46 to -0.22; 237 participants; 4 studies; very low-quality evidence), total hospital stay (MD -2.42 days, 95% CrI -3.91 to -0.94; 197 participants; 3 studies; very low-quality evidence), and operating time (MD -15.32 minutes, 95% CrI -29.03 to -1.69; 192 participants; 4 studies; very low-quality evidence) were lower with low central venous pressure than with control. For the other comparisons, the evidence for difference was either based on single small trials or there was no evidence of differences. None of the trials reported health-related quality of life or time needed to return to work. Paucity of data meant that we could not assess transitivity assumptions and inconsistency for most analyses. When direct and indirect comparisons were available, network meta-analysis provided additional effect estimates for comparisons where there were no direct comparisons. However, the paucity of data decreases the confidence in the results of the network meta-analysis. Low-quality evidence suggests that liver resection using a radiofrequency dissecting sealer may be associated with more adverse events than with the clamp-crush method. Low-quality evidence also suggests that the proportion of people requiring a blood transfusion is higher with low central venous pressure than with acute normovolemic haemodilution plus low central venous pressure; very low-quality evidence suggests that blood transfusion quantity (red blood cells) was lower with fibrin sealant than control; blood transfusion quantity (fresh frozen plasma) was higher with oxidised cellulose than with fibrin sealant; and blood loss, total hospital stay, and operating time were lower with low central venous pressure than with control. There is no evidence to suggest that using special equipment for liver resection is of any benefit in decreasing the mortality, morbidity, or blood transfusion requirements (very low-quality evidence). Radiofrequency dissecting sealer should not be used outside the clinical trial setting since there is low-quality evidence for increased harm without any evidence of benefits. In addition, it should be noted that the sample size was small and the credible intervals were wide, and we cannot rule out considerable benefit or harm with a specific method of liver resection.
Rodriguez-Calero, Miguel Angel; Fernandez-Fernandez, Ismael; Molero-Ballester, Luis Javier; Matamalas-Massanet, Catalina; Moreno-Mejias, Luis; de Pedro-Gomez, Joan Ernest; Blanco-Mavillard, Ian; Morales-Asencio, Jose Miguel
2018-02-08
Patients with difficult venous access experience undesirable effects during healthcare, such as delayed diagnosis and initiation of treatment, stress and pain related to the technique and reduced satisfaction. This study aims to identify risk factors with which to model the appearance of difficulty in achieving peripheral venous puncture in hospital treatment. Case-control study. We will include adult patients requiring peripheral venous cannulation in eight public hospitals, excluding those in emergency situations and women in childbirth or during puerperium. The nurse who performs the technique will record in an anonymised register variables related to the intervention. Subsequently, a researcher will extract the health variables from the patient's medical history. Patients who present one of the following conditions will be assigned to the case group: two or more failed punctures, need for puncture support, need for central access after failure to achieve peripheral access, or decision to reject the technique. The control group will be obtained from records of patients who do not meet the above conditions. It has been stated a minimum sample size of 2070 patients, 207 cases and 1863 controls.A descriptive analysis will be made of the distribution of the phenomenon. The variables hypothesised to be risk factors for the appearance of difficult venous cannulation will be studied using a logistic regression model. The study was funded in January 2017 and obtained ethical approval from the Research Ethics Committee of the Balearic Islands. Informed consent will be obtained prior to data collection. Results will be published in a peer-reviewed scientific journal. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Pealing, Louise; Perel, Pablo; Prieto-Merino, David; Roberts, Ian
2012-01-01
Background Vascular occlusive events can complicate recovery following trauma. We examined risk factors for venous and arterial vascular occlusive events in trauma patients and the extent to which the risk of vascular occlusive events varies with the severity of bleeding. Methods and Findings We conducted a cohort analysis using data from a large international, double-blind, randomised, placebo-controlled trial (The CRASH-2 trial) [1]. We studied the association between patient demographic and physiological parameters at hospital admission and the risk of vascular occlusive events. To assess the extent to which risk of vascular occlusive events varies with severity of bleeding, we constructed a prognostic model for the risk of death due to bleeding and assessed the relationship between risk of death due to bleeding and risk of vascular occlusive events. There were 20,127 trauma patients with outcome data including 204 (1.01%) patients with a venous event (pulmonary embolism or deep vein thrombosis) and 200 (0.99%) with an arterial event (myocardial infarction or stroke). There were 81 deaths due to vascular occlusive events. Increasing age, decreasing systolic blood pressure, increased respiratory rates, longer central capillary refill times, higher heart rates and lower Glasgow Coma Scores (all p<0.02) were strong risk factors for venous and arterial vascular occlusive events. Patients with more severe bleeding as assessed by predicted risk of haemorrhage death had a greatly increased risk for all types of vascular occlusive event (all p<0.001). Conclusions Patients with severe traumatic bleeding are at greatly increased risk of venous and arterial vascular occlusive events. Older age and blunt trauma are also risk factors for vascular occlusive events. Effective treatment of bleeding may reduce venous and arterial vascular occlusive complications in trauma patients. PMID:23251374
Jacobsen, Katja Kemp; Brandt, Ida; Christensen, Anne Vindahl; Rimsø, Bjørk Anine; Krøier, Camilla Julie; Sørensen, Michelle; Smith, Julie; Jensen, Kathrine Overgaard Foss; Larsen, Jeppe Madura
2018-06-01
Deviation in blood collection procedures is a central source of preanalytical variation affecting overall analytical and diagnostic precision. The order of draw of venous sampling is suspected to affect analytical results, in particular for coagulation analysis. Here we compare the procedures in venous blood sampling among clinical biochemistry departments to assess the uniformity of order of blood draw and adherence to international guidelines in the Danish health care system. We collected venous order of draw procedures from 49 clinical biochemistry departments at 22 public hospitals in Denmark. Procedures were compared to the international guidelines fromthe Clinical Laboratory Standards Institute (CLSI) and World Health Organization (WHO), and assessed in relation to department ISO 15189:2012 accreditation. We observed seven different order of draw procedures related to citrate, serum, heparin, and EDTA tubes, and the use of discard tubes in relation to coagulation assays. 31 departments (63.3%) were found to adhere to CLSI and WHO guidelines. A majority of departments instructs the use of discard tubes before collection for coagulation assays in citrate tubes (44 departments; 89.8%). The citrate tube was the first sample tube to be drawn for most departments (35 departments; 75.5%); and the preferred order of non-citrate tubes was serum-heparin-EDTA (36 departments; 73.5%). Adherence to the CLSI and WHO guidelines was not associated with department ISO 15189:2012 accreditation (p = .57). Venous order of draw procedures is diverse at Danish clinical biochemistry departments and show moderate adherence to international guidelines. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Influence of Gravity on Blood Volume and Flow Distribution
NASA Technical Reports Server (NTRS)
Pendergast, D.; Olszowka, A.; Bednarczyk, E.; Shykoff, B.; Farhi, L.
1999-01-01
In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is increased and if there is edema in space. Anecdotal evidence suggests there may be cerebral edema early in flight. Cerebral artery velocity has been shown to be elevated in simulated microgravity. The elevated cerebral artery velocity during simulated microgravity may reflect vasoconstriction of the arteries and not increased cerebral blood flow. The purpose of our investigations was to evaluate the effects of alterations in simulated gravity (+/-), resulting in changes in cardiac output (+/-), and on the blood flow and volume distribution in the lung and brain of human subjects. The first hypothesis of these studies was that blood flow and volume would be affected by gravity, but their distribution in the lung would be independent of gravity and due to vasoactivity changing vascular resistance in lung vessels. The vasodilitation of the lung vasculature (lower resistance) along with increased "compliance" of the heart could account for the absence of increased central venous pressure in microgravity. Secondly, we postulate that cerebral blood velocity is increased in microgravity due to large artery vasoconstriction, but that cerebral blood flow would be reduced due to autoregulation.
Skopets, A A; Lomivorotov, V V; Karakhalis, N B; Makarov, A A; Duman'ian, E S; Lomivorotova, L V
2009-01-01
The purpose of the study was to evaluate the efficiency of oxygen-transporting function of the circulatory system under sevoflurane anesthesia during myocardial revascularization operations under extracorporeal circulation. Twenty-five patients with coronary heart disease were examined. Mean blood pressure, heart rate, cardiac index, total peripheral vascular resistance index, pulmonary pressure, pulmonary wedge pressure, and central venous pressure were measured. Arterial and mixed venous blood oxygen levels, oxygen delivery and consumption index, arteriovenous oxygen difference, and glucose and lactate concentrations were calculated. The study has demonstrated that sevoflurane is an effective and safe anesthetic for myocardial revascularization operations in patients with coronary heart disease. The use of sevoflurane contributes to steady-state oxygen-transporting function of the circulatory system at all surgical stages.
Cardiovascular regulatory response to lower body negative pressure following blood volume loss
NASA Technical Reports Server (NTRS)
Shimizu, M.; Ghista, D. N.; Sandler, H.
1979-01-01
An attempt is made to explain the cardiovascular regulatory responses to lower body negative pressure (LBNP) stress, both in the absence of and following blood or plasma volume loss, the latter being factors regularly observed with short- or long-term recumbency or weightlessness and associated with resulting cardiovascular deconditioning. Analytical expressions are derived for the responses of mean venous pressure and blood volume pooled in the lower body due to LBNP. An analysis is presented for determining the HR change due to LBNP stress following blood volume loss. It is concluded that the reduced orthostatic tolerance following long-term space flight or recumbency can be mainly attributed to blood volume loss, and that the associated cardiovascular responses characterizing this orthostatic intolerance is elicited by the associated central venous pressure response.
Extravasation Injuries in Adults
Al-Benna, S.; O'Boyle, C.; Holley, J.
2013-01-01
Insertion of an intravascular catheter is one of the most common invasive procedures in hospitals worldwide. These intravascular lines are crucial in resuscitation, allow vital medication to be administered, and can be used to monitor the patients' real-time vital parameters. There is, however, growing recognition of potential risks to life and limb associated with their use. Medical literature is now replete with isolated case reports of complications succinctly described by Garden and Laussen (2004) as “An unending supply of “unusual” complications from central venous catheters.” This paper reviews complications of venous and arterial catheters and discusses treatment approaches and methods to prevent complications, based on current evidence and endeavours to provide information and guidance that will enable practitioners to prevent, recognise, and successfully treat extravasation injuries in adults. PMID:23738141
Cerebral venous hypertension and blindness: a reversible complication.
Cuadra, Salvador A; Padberg, Frank T; Turbin, Roger E; Farkas, Jeffrey; Frohman, Larry P
2005-10-01
A 57-year-old woman developed blindness during treatment for sarcoidosis-induced end-stage renal disease. An initial renal transplantation failed, and hemoaccess was maintained with multiple central catheters and upper extremity prosthetic arteriovenous grafts. A successful second transplantation eliminated her need for hemodialysis, but a right brachial to internal jugular graft remained patent. Progressive visual loss 2 years after transplantation prompted ophthalmic evaluation which initially revealed unilateral left optic nerve edema and visual loss, ultimately worsening over several months to no light perception in the left eye, 20/60 vision in the right eye, and bilateral papilledema. Arteriography demonstrated cerebral venous hypertension attributed to the functioning hemoaccess graft. Permanent graft occlusion normalized the papilledema, and visual field defects in the right eye and visual acuity returned to 20/20 in the right eye.
Baroreflex-Mediated Heart Rate and Vascular Resistance Responses 24 h after Maximal Exercise
2003-01-01
of normal physiological function in bedridden patients and astronauts. The implication for failure of CVP and plasma volume to return to baseline... FUNCTION , BLOOD PRES- SURE, CENTRAL VENOUS PRESSURE, PHENYLEPHRINE, NECK PRESSURE, LOWER BODY NEGATIVE PRESSURE, COUNTERMEASURES Increased incidence of...orthostatic hypotension and intol-erance in humans is associated with vascular hypovole-mia and attenuated cardiovascular reflex functions
Baspinar, Osman; Sahin, Derya A; Yildirim, Ali
2016-04-01
We present the case report of a war victim child with severe burn scars, orthopnoea, and dyspnoea due to diffuse pulmonary thromboembolism. During ICU stay, a central venous catheter's 45-mm wire embolised into the heart. The embolised wire was successfully removed via transhepatic access through the creation of an artificial simple snare.