Sample records for shift urine samples

  1. Urine chromium as an estimator of air exposure to stainless steel welding fumes.

    PubMed

    Sjögren, B; Hedström, L; Ulfvarson, U

    1983-01-01

    Welding stainless steel with covered electrodes, also called manual metal arc welding, generates hexavalent airborne chromium. Chromium concentrations in air and post-shift urine samples, collected the same arbitrarily chosen working day, showed a linear relationship. Since post-shift urine samples reflect chromium concentrations of both current and previous stainless steel welding fume exposure, individual urine measurements are suggested as approximate although not exact estimators of current exposure. This study evaluates the practical importance of such measurements by means of confidence limits and tests of validity.

  2. An Evaluation of the Relationship among Urine, Air, and Hand Measures of Exposure to Bisphenol A (BPA) in US Manufacturing Workers.

    PubMed

    Hines, Cynthia J; Christianson, Annette L; Jackson, Matthew V; Ye, Xiaoyun; Pretty, Jack R; Arnold, James E; Calafat, Antonia M

    2018-06-13

    Exposure to bisphenol A (BPA) can be assessed using external and internal exposure measures. We examined the relationship between two measures of external BPA exposure (air and hand-wipe samples) and one of internal exposure (total BPA in urine) for a group of US manufacturing workers. During 2013-2014, we recruited 78 workers from six US companies that made BPA or made products with BPA. We quantified BPA in seven urine samples, two full-shift air samples and in pre- and end-shift hand-wipe samples collected from workers over 2 consecutive days. We examined correlations between creatinine-corrected urinary concentrations of total BPA (total BPACR) and BPA levels in air and hand wipes using Pearson's correlation coefficient. We also applied mixed-effects regression models to examine the relationship between total BPACR with BPA in air (urine~air model) and with BPA in end-shift hand wipes (urine~hand model), separately and together (urine~air+hand model), after adjusting for covariates. End-shift total BPACR strongly correlated with BPA in air (rp = 0.79, P < 0.0001) and nearly as strongly with BPA in end-shift hand wipes (rp = 0.75, P < 0.0001). In mixed-effect models, BPA air concentration and end-shift hand-wipe BPA level were significantly and positively associated with end-shift total BPACR (P < 0.0001 each). We found a significant effect of the Day 1 BPA air concentration on Day 2 total BPACR (P = 0.0104). When BPA air concentration and end-shift hand-wipe BPA level were in the same model, the air concentration (P < 0.0001) was more significant than the hand-wipe level (P = 0.0106). BPA levels in air and end-shift hand wipes strongly correlated with total BPACR, suggesting that both inhalation and dermal contract were likely exposure routes; however, inhalation, on average, appeared to be a more dominant exposure route than dermal contact for these manufacturing workers.

  3. Urinary levoglucosan as a biomarker for woodsmoke exposure in wildland firefighters.

    PubMed

    Naeher, Luke P; Barr, Dana Boyd; Adetona, Olorunfemi; Simpson, Christopher D

    2013-01-01

    Levoglucosan, a sugar anhydride and a combustion breakdown product of cellulose is a dominant organic constituent of particles in woodsmoke. After exposure, levoglucosan is excreted unmetabolized in urine. Urinary levoglucosan was assessed as a biomarker of occupational woodsmoke exposure among wildland firefighters. Urine samples were collected from wildland firefighters before and after their work-shifts on days when they worked at prescribed burns. A total of 97 pairs of pre- and post-shift urine samples were collected from 19 firefighters over 10 prescribed burn shifts. The urine samples were analyzed to determine whether there was an increase in the concentration of levoglucosan from pre- to post-shift after the firefighters had worked at the prescribed burns. Overall, there was an increase in both the urinary volume-based and creatinine corrected levoglucosan concentrations from pre- to post-shift (P < 0.05). However, the direction of change in the concentrations was not consistent. There were increases in urinary levoglucosan concentration from pre- to post-shift in 63% of the person-day samples, and in only 58% of the person-day samples for the creatinine corrected concentrations. Although there was an overall increase in urinary concentrations of levoglucosan, results suggest that other sources apart from woodsmoke affected the urinary levels of this biomarker in wildland firefighters. Therefore, urinary levoglucosan may not be effective as a biomarker of woodsmoke exposure in this setting.

  4. Modelling the acid/base 1H NMR chemical shift limits of metabolites in human urine.

    PubMed

    Tredwell, Gregory D; Bundy, Jacob G; De Iorio, Maria; Ebbels, Timothy M D

    2016-01-01

    Despite the use of buffering agents the 1 H NMR spectra of biofluid samples in metabolic profiling investigations typically suffer from extensive peak frequency shifting between spectra. These chemical shift changes are mainly due to differences in pH and divalent metal ion concentrations between the samples. This frequency shifting results in a correspondence problem: it can be hard to register the same peak as belonging to the same molecule across multiple samples. The problem is especially acute for urine, which can have a wide range of ionic concentrations between different samples. To investigate the acid, base and metal ion dependent 1 H NMR chemical shift variations and limits of the main metabolites in a complex biological mixture. Urine samples from five different individuals were collected and pooled, and pre-treated with Chelex-100 ion exchange resin. Urine samples were either treated with either HCl or NaOH, or were supplemented with various concentrations of CaCl 2 , MgCl 2 , NaCl or KCl, and their 1 H NMR spectra were acquired. Nonlinear fitting was used to derive acid dissociation constants and acid and base chemical shift limits for peaks from 33 identified metabolites. Peak pH titration curves for a further 65 unidentified peaks were also obtained for future reference. Furthermore, the peak variations induced by the main metal ions present in urine, Na + , K + , Ca 2+ and Mg 2+ , were also measured. These data will be a valuable resource for 1 H NMR metabolite profiling experiments and for the development of automated metabolite alignment and identification algorithms for 1 H NMR spectra.

  5. The relationship of blood- and urine-boron to boron exposure in borax-workers and usefulness of urine-boron as an exposure marker.

    PubMed Central

    Culver, B D; Shen, P T; Taylor, T H; Lee-Feldstein, A; Anton-Culver, H; Strong, P L

    1994-01-01

    Daily dietary-boron intake and on-the-job inspired boron were compared with blood- and urine-boron concentrations in workers engaged in packaging and shipping borax. Fourteen workers handling borax at jobs of low, medium, and high dust exposures were sampled throughout full shifts for 5 consecutive days each. Airborne borax concentrations ranged from means of 3.3 mg/m3 to 18 mg/m3, measured gravimetrically. End-of-shift mean blood-boron concentrations ranged from 0.11 to 0.26 microgram/g; end-of-shift mean urine concentrations ranged from 3.16 to 10.72 micrograms/mg creatinine. Creatinine measures were used to adjust for differences in urine-specific gravity such that 1 ml of urine contains approximately 1 mg creatinine. There was no progressive increase in end-of-shift blood- or urine-boron concentrations across the days of the week. Urine testing done at the end of the work shift gave a somewhat better estimate of borate exposure than did blood testing, was sampled more easily, and was analytically less difficult to perform. Personal air samplers of two types were used: one, the 37-mm closed-face, two-piece cassette to estimate total dust and the other, the Institute of Occupational Medicine (IOM) sampler to estimate inspirable particulate mass. Under the conditions of this study, the IOM air sampler more nearly estimated human exposure as measured by blood- and urine-boron levels than did the sampler that measured total dust.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7889874

  6. Jet Fuel Exposure and Neurological Health in Military Personnel

    DTIC Science & Technology

    2011-07-01

    and dermal samples E Absorbed Dose measure: Exhaled breath, urine , blood F Lifestyle factors (smoking), use of protective equipment (gloves...toluene, ethylbenzene, xylene, and naphthalene. To assess personal absorbed dose levels to JP8 components, exhaled breath and urine samples were...the following primary analytes of interest were measured: benzene, toluene, ethylbenzene, xylene, and naphthalene. Pre- and post- shift urine samples

  7. Stone former urine proteome demonstrates a cationic shift in protein distribution compared to normal.

    PubMed

    Kolbach-Mandel, Ann M; Mandel, Neil S; Hoffmann, Brian R; Kleinman, Jack G; Wesson, Jeffrey A

    2017-08-01

    Many urine proteins are found in calcium oxalate stones, yet decades of research have failed to define the role of urine proteins in stone formation. This urine proteomic study compares the relative amounts of abundant urine proteins between idiopathic calcium oxalate stone forming and non-stone forming (normal) cohorts to identify differences that might correlate with disease. Random mid-morning urine samples were collected following informed consent from 25 stone formers and 14 normal individuals. Proteins were isolated from urine using ultrafiltration. Urine proteomes for each sample were characterized using label-free spectral counting mass spectrometry, so that urine protein relative abundances could be compared between the two populations. A total of 407 unique proteins were identified with the 38 predominant proteins accounting for >82% of all sample spectral counts. The most highly abundant proteins were equivalent in stone formers and normals, though significant differences were observed in a few moderate abundance proteins (immunoglobulins, transferrin, and epidermal growth factor), accounting for 13 and 10% of the spectral counts, respectively. These proteins contributed to a cationic shift in protein distribution in stone formers compared to normals (22% vs. 18%, p = 0.04). Our data showing only small differences in moderate abundance proteins suggest that no single protein controls stone formation. Observed increases in immunoglobulins and transferrin suggest increased inflammatory activity in stone formers, but cannot distinguish cause from effect in stone formation. The observed cationic shift in protein distribution would diminish protein charge stabilization, which could lead to protein aggregation and increased risk for crystal aggregation.

  8. Nightshift work job exposure matrices and urinary 6-sulfatoxymelatonin levels among healthy Chinese women.

    PubMed

    Ji, Bu-Tian; Gao, Yu-Tang; Shu, Xiao-Ou; Yang, Gong; Yu, Kai; Xue, Shou-Zheng; Li, Hong-Lan; Liao, Linda M; Blair, Aaron; Rothman, Nathaniel; Zheng, Wei; Chow, Wong-Ho

    2012-11-01

    Six-sulfatoxymelatonin (aMT6s) is a primary urinary metabolite of melatonin. We examined the association between aMT6s levels and shift work estimated by a job exposure matrix (JEM) among healthy participants of the Shanghai Women's Health Study. Creatinine-adjusted aMT6s levels were measured in the urine samples of 300 women and related to JEM shift work categories. Adjusted geometric means of aMT6s levels from urine samples collected before 08:00 hours were lower among persons holding nighttime shift work jobs. The adjusted aMT6s levels (ng/mg creatinine) were 8.36 [95% confidence intervals (95% CI) 4.47-15.6], 6.37 (95% CI 3.53-11.5), 6.20 (95% CI 3.33-11.5), 3.81 (95% CI 2.02-7.19), and 3.70 (95% CI 1.92-7.11) from the lowest (never held a shift work job) to the highest (current job likely involved all-night shift work) shift work JEM scores (P=0.05). Our results indicate that nightshift work JEM scores were significantly and inversely associated with aMT6s levels in early morning spot urine samples collected between 07:00-08:00 hours.

  9. Biomonitoring of N-ethyl-2-pyrrolidone in automobile varnishers.

    PubMed

    Koslitz, Stephan; Meier, Swetlana; Schindler, Birgit Karin; Weiss, Tobias; Koch, Holger Martin; Brüning, Thomas; Käfferlein, Heiko Udo

    2014-12-01

    N-alkyl-2-pyrrolidones are important organic solvents for varnishes in industry. This study investigates exposure to N-ethyl-2-pyrrolidone (NEP) in varnishing of hard plastic components in an automobile plant. Two specific biomarkers of exposure, 5-hydroxy-N-ethyl-2-pyrrolidone (5-HNEP) and 2-hydroxy-N-ethylsuccinimide (2-HESI), were analyzed in urine samples of 14 workers. For this purpose, pre-shift, post-shift and next day pre-shift urine samples were collected midweek. Twelve workers performed regular work tasks (loading, wiping and packing), whereas two workers performed special work tasks including cleaning the sprayer system with organic solvents containing N-alkyl-2-pyrrolidones. Spot urine samples of nine non-exposed persons of the same plant served as controls. Median post-shift urinary levels of workers with regular work tasks (5-HNEP: 0.15 mg/L; 2-HESI: 0.19 mg/L) were ∼5-fold higher compared to the controls (0.03 mg/L each). Continuously increasing metabolite levels, from pre-shift via post-shift to pre-shift samples of the following day, were observed in particular for the two workers with the special working tasks. Maximum levels were 31.01 mg/L (5-HNEP) and 8.45 mg/L (2-HESI). No clear trend was evident for workers with regular working tasks. In summary, we were able to show that workers can be exposed to NEP during varnishing tasks in the automobile industry. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Biological monitoring of workers exposed to 4,4'-methylenediphenyl diisocyanate (MDI) in 19 French polyurethane industries.

    PubMed

    Robert, A; Ducos, P; Francin, J M; Marsan, P

    2007-04-01

    To study the range of urinary levels of 4,4'-methylenedianiline (MDA), a metabolite of methylenediphenyl diisocyanate (MDI), across factories in the polyurethane industries and to evaluate the validity of this biomarker to assess MDI occupational exposure. Workers exposed to MDI, as well as non-occupationally exposed subjects, were studied and pre- and post-shift urine samples were collected from 169 workers of 19 French factories and 120 controls. Details on work activities and practices were collected by a questionnaire and workers were classified into three job categories. The identification and quantification of the total urinary MDA were performed by high-performance liquid chromatography with electrochemical detection (HPLC/EC). For all the factories, MDA was detectable in 73% of the post-shift urine samples. These post-shift values, in the range of <0.10 (detection limit)-23.60 microg/l, were significantly higher than those of the pre-shift samples. Urinary MDA levels in the control group were in the range of < 0.10-0.80 microg/l. The degree of automation of the mixing operation (polyols and MDI) appears as a determinant in the extent of exposure levels. The highest amounts of MDA in urine were found in the spraying or hot processes. The excretion levels of the workers directly exposed to the hardener containing the MDI monomer were significantly higher than those of the other workers. In addition, skin exposure to MDI monomer or to polyurethane resin during the curing step were always associated with significant MDA levels in urine. Total MDA in post-shift urine samples is a reliable biomarker to assess occupational exposure to MDI in various industrial applications and to help factories to improve their manufacturing processes and working practices. A biological guiding value not exceeding 7 microg/l (5 microg/g creatinine) could be proposed in France.

  11. Unmetabolized VOCs in urine as biomarkers of low level occupational exposure.

    PubMed

    Janasik, Beata; Jakubowski, Marek; Wesołowski, Wiktor; Kucharska, Małgorzata

    2010-01-01

    To compare the usefulness of determining unchanged forms of volatile organic compounds (VOCs), namely toluene (TOL), ethylbenzene (EB) and xylene (XYL), in urine with the effectiveness of the already used biomarkers of occupational exposure. Surveys were conducted in two workplaces (paint factory and footwear factory). In total, 65 subjects participated in the study. Air samples were collected using individual samplers during work shift. Urine and blood samples were collected at the end of work shift. Urine samples were analyzed for unchanged compounds and selected metabolites, while blood samples were tested for unchanged compounds. VOCs in blood and urine were determined by solid phase microextraction gas chromatography (SPME-GC-MS). In the paint factory, the geometric mean (GM) concentrations of VOCs in the air ranged as follows: 0.2-4.7 mg/m(3) for TOL, 0.4-40.9 mg/m(3) for EB and 0.1-122.6 mg/m(3) for XYL. In the footwear factory, the GM concentration of TOL in the air amounted to 105.4 mg/m(3). A significant correlation (p < 0.05) was observed between VOCs in blood, urine and air. The regression analyses performed for paint factory workers showed that TOL-U and TOL-B were better biomarkers of exposure (r = 0.72 and r = 0.81) than benzoic acid (r = 0.12) or o-cresol (r = 0.55). The findings of the study point out that the concentration of unchanged VOCs in urine can be a reliable biological indicator of low level occupational exposure to these compounds.

  12. Trends in Occupational Exposure to Styrene in the European Glass Fibre-Reinforced Plastics Industry

    PubMed Central

    Van Rooij, J. G. M.; Kasper, A.; Triebig, G.; Werner, P.; Kromhout, H.

    2008-01-01

    Aim: This study presents temporal trends of styrene exposure for workers in the European glass fibre-reinforced plastics (GRP) industry during the period 1966–2002. Methods: Data of personal styrene exposure measurements were retrieved from reports, databases and peer-reviewed papers. Only sources with descriptive statistics of personal measurements were accepted. The styrene exposure data cover personal air samples and biological monitoring data, that is, urinary styrene metabolites (mandelic acid and/or phenylglyoxylic acid) and styrene in blood. Means of series of measurements were categorized by year, country, production process, job and sampling strategy. Linear mixed models were used to identify temporal trends and factors affecting exposure levels. Results: Personal exposure measurements were available from 60 reports providing data on 24145 1–8-h time-weighted average shift personal air samples. Available data of biological exposure indicators included measurements of mandelic acid in post-shift urine (6361 urine samples being analysed). Trend analyses of the available styrene exposure data showed that the average styrene concentration in the breathing zone of open-mould workers in the European GRP industry has decreased on average by 5.3% per year during the period 1966–1990 and by only 0.4% annually in the period after 1990. The highest exposures were measured in Southern Europe and the lowest exposures in Northern Europe with Central Europe in between. Biological indicators of styrene (mandelic acid in post-shift urine) showed a somewhat steeper decline (8.9%), most likely because urine samples were collected in companies that showed a stronger decrease of styrene exposure in air than GRP companies where no biological measurements were carried out. PMID:18550625

  13. Melatonin and cortisol assessment of circadian shifts in astronauts before flight

    NASA Technical Reports Server (NTRS)

    Whitson, P. A.; Putcha, L.; Chen, Y. M.; Baker, E.

    1995-01-01

    Melatonin and cortisol were measured in saliva and urine samples to assess the effectiveness of a 7-day protocol combining bright-light exposure with sleep shifting in eliciting a 12-hr phase-shift delay in eight U.S. Space Shuttle astronauts before launch. Baseline acrophases for 15 control subjects with normal sleep-wake cycles were as follows: cortisol (saliva) at 0700 (0730 in urine); melatonin (saliva) at 0130 (6-hydroxymelatonin sulfate at 0230 in urine). Acrophases of the astronaut group fell within 2.5 hr of these values before the treatment protocols were begun. During the bright-light and sleep-shifting treatments, both absolute melatonin production and melatonin rhythmicity were diminished during the first 3 treatment days; total daily cortisol levels remained constant throughout the treatment. By the fourth to sixth day of the 7-day protocol, seven of the eight crew members showed phase delays in all four measures that fell within 2 hr of the expected 11- to 12-hr shift. Although cortisol and melatonin rhythms each corresponded with the phase shift, the rhythms in these two hormones did not correspond with each other during the transition.

  14. Melatonin and cortisol assessment of circadian shifts in astronauts before flight.

    PubMed

    Whitson, P A; Putcha, L; Chen, Y M; Baker, E

    1995-04-01

    Melatonin and cortisol were measured in saliva and urine samples to assess the effectiveness of a 7-day protocol combining bright-light exposure with sleep shifting in eliciting a 12-hr phase-shift delay in eight U.S. Space Shuttle astronauts before launch. Baseline acrophases for 15 control subjects with normal sleep-wake cycles were as follows: cortisol (saliva) at 0700 (0730 in urine); melatonin (saliva) at 0130 (6-hydroxymelatonin sulfate at 0230 in urine). Acrophases of the astronaut group fell within 2.5 hr of these values before the treatment protocols were begun. During the bright-light and sleep-shifting treatments, both absolute melatonin production and melatonin rhythmicity were diminished during the first 3 treatment days; total daily cortisol levels remained constant throughout the treatment. By the fourth to sixth day of the 7-day protocol, seven of the eight crew members showed phase delays in all four measures that fell within 2 hr of the expected 11- to 12-hr shift. Although cortisol and melatonin rhythms each corresponded with the phase shift, the rhythms in these two hormones did not correspond with each other during the transition.

  15. Occupational exposure to diisocyanates in polyurethane foam factory workers.

    PubMed

    Świerczyńska-Machura, Dominika; Brzeźnicki, Sławomir; Nowakowska-Świrta, Ewa; Walusiak-Skorupa, Jolanta; Wittczak, Tomasz; Dudek, Wojciech; Bonczarowska, Marzena; Wesolowski, Wiktor; Czerczak, Sławomir; Pałczyński, Cezary

    2015-01-01

    The aim of the study was to evaluate health effects of occupational exposure to diisocyanates (DIC) among polyurethane foam products factory workers. Thirty workers had a physical examination, skin prick tests with common allergens, allergen-specific immunoglobulin E (IgE) antibodies to diisocyanates and pulmonary function tests. Concentrations of selected isocyanates in the workplace air samples as well as concentration of their metabolites in the urine samples collected from the workers of the plant were determined. The most frequent work-related symptoms reported by the examined subjects were rhinitis and skin symptoms. Sensitization to at least 1 common allergen was noted in 26.7% of the subjects. Spirometry changes of bronchial obstruction of a mild degree was observed in 5 workers. The specific IgE antibodies to toluene diisocyanate (TDI) and 4,4'-methylenebis(phenyl isocyanate) (MDI) were not detected in any of the patients' serum. Cellular profiles of the collected induced sputum (ISP) did not reveal any abnormalities. Air concentrations of TDI isomers ranged 0.2-58.9 μg/m3 and in 7 cases they exceeded the Combined Exposure Index (CEI) value for those compounds. Concentrations of TDI metabolites in post-shift urine samples were significantly higher than in the case of pre-shift urine samples and in 6 cases they exceeded the British Biological Monitoring Guidance Value (BMGV - 1 μmol amine/mol creatinine). We didn't find a correlation between urinary concentrations of TDI, concentrations in the air and concentrations of toluenediamine (TDA) in the post shift urine samples. Lack of such a correlation may be an effect of the respiratory protective equipment use. Determination of specific IgE in serum is not sensitive enough to serve as a biomarker. Estimation of concentrations of diisocyanate metabolites in urine samples and the presence of work-related allergic symptoms seem to be an adequate method for occupational exposure monitoring of DIC, which may help to determine workers at risk as well as to recognize hazardous workplaces. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  16. Biological effect markers in exhaled breath condensate and biomonitoring in welders: impact of smoking and protection equipment.

    PubMed

    Gube, Monika; Ebel, Joachim; Brand, Peter; Göen, Thomas; Holzinger, Karl; Reisgen, Uwe; Kraus, Thomas

    2010-10-01

    The objective of this study was to investigate the effect of welding as well as the impact of smoking and protection measures on biological effect markers in exhaled breath condensate. Additionally, biomonitoring of chromium, aluminium and nickel in urine was performed to quantify internal exposure. Exhaled breath condensate (EBC) and urine samples of 45 male welders and 24 male non-exposed control subjects were collected on Friday pre-shift and after 8 h of work post-shift. In EBC, biological effect markers such as malondialdehyde, nitrite, nitrate, 3-nitrotyrosine, tyrosine, hydroxyproline, proline, H(2)O(2) and pH-value were measured while aluminium, nickel, and chromium were measured in the urine samples. Although internal exposure to aluminium, nickel and chromium in this study was low, welders showed significantly increased concentrations of all these parameters at baseline compared to non-exposed controls. Moreover, welders had higher nitrate concentrations in EBC at baseline and after shift. Nitrate concentration was considerably lower after shift if personal protection equipment was used. H(2)O(2) was increased only when subjects smoked during shift. It has been shown that welding-associated long-term and short-term health effects could be detected in a population of welders. The results also showed that using personal protection equipment is of high importance and H(2)O(2) may be an effect marker associated with smoking rather than with welding fumes, while nitrate in EBC seems to be sensitive to welding fume exposure.

  17. Commercial Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) Testing is Not Vulnerable to Incidental Alcohol Exposure in Pregnant Women.

    PubMed

    Ondersma, Steven J; Beatty, Jessica R; Rosano, Thomas G; Strickler, Ronald C; Graham, Amy E; Sokol, Robert J

    2016-01-02

    Ethyl Glucoronide (EtG) and Ethyl Sulfate (EtS) have shown promise as biomarkers for alcohol and may be sensitive enough for use with pregnant women in whom even low-level alcohol use is important. However, there have been reports of over-sensitivity of EtG and EtS to incidental exposure to sources such as alcohol-based hand sanitizer. Further, few studies have evaluated these biomarkers among pregnant women, in whom the dynamics of these metabolites may differ. This study evaluated whether commercial EtG-EtS testing was vulnerable to high levels of environmental exposure to alcohol in pregnant women. Two separate samples of five nurses-one pregnant and the other postpartum, all of whom reported high levels of alcohol-based hand sanitizer use-provided urine samples before and 4-8 hours after rinsing with alcohol-based mouthwash and using hand sanitizer. The five pregnant nurses provided urine samples before, during, and after an 8-hour nursing shift, during which they repeatedly cleansed with alcohol-based hand sanitizer (mean 33.8 uses). The five postpartum nurses used hand sanitizer repeatedly between baseline and follow-up urine samples. No urine samples were positive for EtG-EtS at baseline or follow-up, despite use of mouthwash and-in the pregnant sample-heavy use of hand sanitizer (mean of 33.8 uses) throughout the 8-hour shift. Current, commercially available EtG-EtS testing does not appear vulnerable to even heavy exposure to incidental sources of alcohol among pregnant and postpartum women.

  18. Biological monitoring of benzene exposure for process operators during ordinary activity in the upstream petroleum industry.

    PubMed

    Bråtveit, Magne; Kirkeleit, Jorunn; Hollund, Bjørg Eli; Moen, Bente E

    2007-07-01

    This study characterized the exposure of crude oil process operators to benzene and related aromatics during ordinary activity and investigated whether the operators take up benzene at this level of exposure. We performed the study on a fixed, integrated oil and gas production facility on Norway's continental shelf. The study population included 12 operators and 9 referents. We measured personal exposure to benzene, toluene, ethylbenzene and xylene during three consecutive 12-h work shifts using organic vapour passive dosimeter badges. We sampled blood and urine before departure to the production facility (pre-shift), immediately after the work shift on Day 13 of the work period (post-shift) and immediately before the following work shift (pre-next shift). We also measured the exposure to hydrocarbons during short-term tasks by active sampling using Tenax tubes. The arithmetic mean exposure over the 3 days was 0.042 ppm for benzene (range <0.001-0.69 ppm), 0.05 ppm for toluene, 0.02 ppm for ethylbenzene and 0.03 ppm for xylene. Full-shift personal exposure was significantly higher when the process operators performed flotation work during the shift versus other tasks. Work in the flotation area was associated with short-term (6-15 min) arithmetic mean exposure to benzene of 1.06 ppm (range 0.09-2.33 ppm). The concentrations of benzene in blood and urine did not differ between operators and referents at any time point. When we adjusted for current smoking in regression analysis, benzene exposure was significantly associated with the post-shift concentration of benzene in blood (P = 0.01) and urine (P = 0.03), respectively. Although these operators perform tasks with relatively high short-term exposure to benzene, the full-shift mean exposure is low during ordinary activity. Some evidence indicates benzene uptake within this range of exposure.

  19. Occupational Exposure to Polycyclic Aromatic Hydrocarbons in Polish Coke Plant Workers.

    PubMed

    Zając, Joanna; Gomółka, Ewa; Maziarz, Barbara; Szot, Wojciech

    2016-11-01

    Assessment of occupational exposure to polycyclic aromatic hydrocarbons (PAHs) is an urgent and important task to prevent workers' illnesses. 1-Hydroxypyrene is one of the most commonly used biomarkers. The presented study assessed exposure to PAHs molecules among 619 individuals, men working in coke plant. Average number of years spent on working posts in exposition to PAHs was 31.5 years with standard deviation = 5.3. About 35% were smokers with 14.7 cigarettes per day. For each individual, 1-hydroxypyrene concentration in urine samples was measured. Urine 1-hydroxypyrene concentration correlated with air PAHs concentration. Difference between smokers and non-smokers was statistically significant. The median value for post-shift samples was 1.3 µg g -1 and for pre-shift sample concentration reached 0.3 µg g -1 Maximal assessed concentration was 7.6 µg g -1 among pre-shift samples and 27.8 µg g -1 among post-shift samples. The most exposed working posts were coke oven workers and coal derivatives production workers. Results obtained in presented study are relatively low in comparison to other countries or other Polish results but for further improvement a regular measurement of any PAHs' biomarker should be included to standard periodic health examinations for coke plant workers. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  20. Hydration amongst nurses and doctors on-call (the HANDS on prospective cohort study).

    PubMed

    El-Sharkawy, Ahmed M; Bragg, Damian; Watson, Phillip; Neal, Keith; Sahota, Opinder; Maughan, Ronald J; Lobo, Dileep N

    2016-08-01

    Dehydration of as little 2% of total body weight may impair physical and cognitive performance. The aim of this study was to investigate the prevalence of dehydration at the start and end of shifts in nurses and doctors on-call. The secondary aims were to assess the relation between hydration status and cognitive function. This prospective cohort study was conducted on nurses and doctors working on medical and surgical admissions wards at a university teaching hospital. Participants arrived on the ward approximately 20 min before their shift and were asked to provide a urine sample. Height and weight were then measured. A 10 mL blood sample was analysed for full blood count, serum urea and electrolytes, and blood glucose. Cognitive function was assessed using a series of computer-based tests including the Stroop Colour Naming Interference Test and Sternberg Memory Paradigm. Participants then worked normally but were asked to keep a fluid diary for the duration of their shift and fluid balance was estimated. Tests were repeated at the end of the shift. Dehydration was defined as urine osmolality >800 mOsmol/kg and oliguria was defined as urine output <0.5 ml/kg/hour. We recruited 92 nurses and doctors, of whom 88 completed the study, amounting to 130 shifts. 52% participated for one shift, and 48% for two shifts. Thirty-six percent of participants were dehydrated at the start of the shift and 45% were dehydrated at the end of their shift. Mean (SD) urinary osmolality was significantly greater at the end of the shift when compared with the start [720 (282) vs. 622 (297) mOsm/kg, P = 0.031). Moreover, 41% were oliguric at the end of the shift. Single number and five-letter Sternberg short-term memory tests were significantly impaired in dehydrated participants (P < 0.05). This study highlights that a significant proportion of nurses and doctors were dehydrated at the start and end of medical and surgical shifts. Dehydration was associated with some impairment of cognitive function. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  1. Commercial Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) Testing is not Vulnerable to Incidental Alcohol Exposure in Pregnant Women

    PubMed Central

    Beatty, Jessica R.; Rosano, Thomas G.; Strickler, Ronald C.; Graham, Amy E.; Sokol, Robert J.

    2016-01-01

    Background Ethyl Glucoronide (EtG) and Ethyl Sulfate (EtS) have shown promise as biomarkers for alcohol and may be sensitive enough for use with pregnant women in whom even low-level alcohol use is important. However, there have been reports of over-sensitivity of EtG and EtS to incidental exposure to sources such as alcohol-based hand sanitizer. Further, few studies have evaluated these biomarkers among pregnant women, in whom the dynamics of these metabolites may differ. Objectives This study evaluated whether commercial EtG-EtS testing was vulnerable to high levels of environmental exposure to alcohol in pregnant women. Methods Two separate samples of five nurses—one pregnant and the other postpartum, all of whom reported high levels of alcohol-based hand sanitizer use—provided urine samples before and 4–8 hours after rinsing with alcohol-based mouthwash and using hand sanitizer. The five pregnant nurses provided urine samples before, during, and after an 8-hour nursing shift, during which they repeatedly cleansed with alcohol-based hand sanitizer (mean 33.8 uses). The five postpartum nurses used hand sanitizer repeatedly between baseline and follow-up urine samples. Results No urine samples were positive for EtG-EtS at baseline or follow-up, despite use of mouthwash and—in the pregnant sample—heavy use of hand sanitizer (mean of 33.8 uses) throughout the 8-hour shift. Conclusions/Importance Current, commercially available EtG-EtS testing does not appear vulnerable to even heavy exposure to incidental sources of alcohol among pregnant and postpartum women. PMID:26771303

  2. Hydration Status, Kidney Function, and Kidney Injury in Florida Agricultural Workers.

    PubMed

    Mix, Jacqueline; Elon, Lisa; Vi Thien Mac, Valerie; Flocks, Joan; Economos, Eugenia; Tovar-Aguilar, Antonio J; Stover Hertzberg, Vicki; McCauley, Linda A

    2018-05-01

    Recent findings suggest that laboring in hot occupational environments is related to kidney damage in agricultural workers. We examined hydration status and kidney function in 192 Florida agricultural workers. Blood and urine samples were collected over 555 workdays during the summers of 2015 and 2016. Urine-specific gravity (USG), serum creatinine, and other kidney function markers were examined pre- and post-shift on each workday. Multivariable mixed modeling was used to examine the association of risk factors with hydration status and acute kidney injury (AKI). Approximately 53% of workers were dehydrated (USG ≥1.020) pre-shift and 81% post-shift; 33% of participants had AKI on at least one workday. The odds of AKI increased 47% for each 5-degree (°F) increase in heat index. A strikingly high prevalence of dehydration and AKI exists in Florida agricultural workers.

  3. Environmental tobacco smoke exposure among casino dealers.

    PubMed

    Achutan, Chandran; West, Christine; Mueller, Charles; Bernert, John T; Bernard, Bruce

    2011-04-01

    This study quantified casino dealers' occupational exposure to environmental tobacco smoke (ETS). We measured casino dealers' exposure to ETS components by analyzing full-shift air and preshift and postshift urine samples. Casino dealers were exposed to nicotine, 4-vinyl pyridine, benzene, toluene, naphthalene, formaldehyde, acetaldehyde, solanesol, and respirable suspended particulates. Levels of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) in urine increased significantly during an 8-hour work shift both with and without adjustment for creatinine clearance. Creatinine-unadjusted cotinine significantly increased during the 8-hour shift, but creatinine-adjusted cotinine did not increase significantly. Casino dealers at the three casinos were exposed to airborne ETS components and absorbed an ETS-specific component into their bodies, as demonstrated by detectable levels of urinary NNAL. The casinos should ban smoking on their premises and offer employee smoking cessation programs.

  4. Seasonal variation in natural abundance of 2H and 18O in urine samples from rural Nigeria

    PubMed Central

    Dugas, Lara R.; Brieger, William; Tayo, Bamidele O.; Alabi, Tunrayo; Schoeller, Dale A.; Luke, Amy

    2015-01-01

    The doubly labeled water (DLW) method is used to measure free-living energy expenditure in humans. Inherent to this technique is the assumption that natural abundances of stable isotopes 2H and 18O in body water remain constant over the course of the measurement period and after elimination of the loading dose of DLW will return to the same predose level. To determine variability in the natural abundances of 2H and 18O in humans living in a region with seasonal shifts in rain patterns and sources of drinking water, over the course of 12 mo we collected weekly urine samples from four individuals living in southwest Nigeria as well as samples of their drinking water. From ongoing regional studies of hypertension, obesity, and energy expenditure, we estimated average water turnover rate, urine volumes, and sodium and potassium excretion. Results suggest that 2H and 18O in urine, mean concentrations of urinary sodium and potassium, urine volume, and total body turnover differed significantly from dry to rainy season. Additionally, seasonal weather variables (mean monthly maximum temperatures, total monthly rainfall, and minimum relative humidity) were all significantly associated with natural abundances in urine. No seasonal difference was observed in drinking water samples. Findings suggest that natural abundances in urine may not remain constant as assumed, and studies incorporating DLW measurements across the transition of seasons should interpret results with caution unless appropriate doses of the tracers are used. PMID:25977450

  5. [Occupational exposure to methyl tert-butyl ether (MTBE) at an oil refinery].

    PubMed

    Perbellini, L; Pasini, F; Prigioni, P; Rosina, A

    2003-01-01

    Methyl tert-butyl ether (MTBE) is widely used as an additive to gasoline, to increase oxygen content and reduce tailpipe emission of carbon monoxide. Our research dealt with 37 refinery workers in order to measure their occupational exposure to MTBE during two different seasonal periods. They provided blood and urine samples before and after a work shift during which they wore an active charcoal sampler for solvents. All samples were analysed by a gas-chromatograph equipped with a mass spectrometer detector. The concentration in air of MTBE was very low (median: 25 micrograms/m3 in spring and 5 micrograms/m3 in autumn). The blood and urine concentrations of MTBE at the end of the work shift were higher than those found before the shift. The increment in biological samples confirmed a small intake of MTBE by refinery workers: the biological monitoring of occupational exposure to this solvent yielded reliable results. Blood and urinary concentrations of MTBE obtained from workers split in relation to their smoking habit did not give a statistic significance to say that cigarette smoke is not a confusion factor in monitoring exposure to MTBE.

  6. Human urine as test material in 1H NMR-based metabonomics: recommendations for sample preparation and storage.

    PubMed

    Lauridsen, Michael; Hansen, Steen H; Jaroszewski, Jerzy W; Cornett, Claus

    2007-02-01

    Metabonomic approaches are believed to have the capability of revolutionizing diagnosis of diseases and assessment of patient conditions after medical interventions. In order to ensure comparability of metabonomic 1H NMR data from different studies, we suggest validated sample preparation guidelines for human urine based on a stability study that evaluates effects of storage time and temperature, freeze-drying, and the presence of preservatives. The results indicated that human urine samples should be stored at or below -25 degrees C, as no changes in the 1H NMR fingerprints have been observed during storage at this temperature for 26 weeks. Formation of acetate, presumably due to microbial contamination, was occasionally observed in samples stored at 4 degrees C without addition of a preservative. Addition of a preserving agent is not mandatory provided that the samples are stored at -25 degrees C. Thus, no differences were observed between 1H NMR spectra of nonpreserved urines and urines with added sodium azide and stored at -25 degrees C, whereas the presence of sodium fluoride caused a shift of especially citrate resonances. Freeze-drying of urine and reconstitution in D2O at pH 7.4 resulted in the disappearance of the creatinine CH2 signal at delta 4.06 due to deuteration. A study evaluating the effects of phosphate buffer concentration on signal variability and assessment of the probability of citrate or creatinine resonances crossing bucket border (a boundary between adjacent integrated regions) led to the conclusion that a minimum buffer concentration of 0.3 M is adequate for normal urines used in this study. However, final buffer concentration of 1 M will be required for very concentrated urines.

  7. Highly sensitive on-site detection of glucose in human urine with naked eye based on enzymatic-like reaction mediated etching of gold nanorods.

    PubMed

    Zhang, Zhiyang; Chen, Zhaopeng; Cheng, Fangbin; Zhang, Yaowen; Chen, Lingxin

    2017-03-15

    Based on enzymatic-like reaction mediated etching of gold nanorods (GNRs), an ultrasensitive visual method was developed for on-site detection of urine glucose. With the catalysis of MoO 4 2 - , GNRs were efficiently etched by H 2 O 2 which was generated by glucose-glucose oxidase enzymatic reaction. The etching of GNRs lead to a blue-shift of logitudinal localized surface plasmon resonance of GNRs, accompanied by an obvious color change from blue to red. The peak-shift and the color change can be used for detection of glucose by the spectrophotometer and the naked eyes. Under optimal condition, an excellent sensitivity toward glucose is obtained with a detection limit of 0.1μM and a visual detection limit of 3μM in buffer solution. Benefiting from the high sensitivity, the successful colorimetric detection of glucose in original urine samples was achieved, which indicates the practical applicability to the on-site determination of urine glucose. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Circadian rhythmicity of the urinary excretion of mercury, potassium and catecholamines in unconventional shift-work systems.

    PubMed

    Vokac, Z; Gundersen, N; Magnus, P; Jebens, E; Bakka, T

    1980-09-01

    The round the clock urinary excretion rates of mercury were assessed for two series of unconventional patterns of activity and sleep in subjects who were not exposed to occupational, medical, or other obvious sources of mercury. In the first series the urine was collected in 3-h periods from six subjects during the first and last 2 d of a four-week, continuous 6-h shift (car ferry, watches either 0800--1400 and 2000--0200 or 1400--2000 and 0200--0800). In the second series the urine was collected in 4-h periods from five subjects working an 8-h experimental rotation shift compressed into 5 d (work two mornings--8-h interval--work two nights--8-h interval--work two afternoons). The mean daily excretion rate of the 11 subjects (48 investigation days, 334 urine samples) was 14.5 pmol of mercury/min (range 5.5--24.4 pmol of mercury/min). The mercury excretion oscillated regularly during 24 h by +/- 20--25% of the individual's daily mean excretion rates. The peak excretion rates were found at 0652 in the first and 0642 in the second series (cosinor treatment). Due to the circadian rhythm the mean 24-h excretion rates were best represented (correlation coefficient 0.92) by analyses of urine produced around noon (spot samples, collection periods 1100--1400 and 1000-1400, respectively). The circadian oscillations of mercury excretion were not influenced by the widely different and varying activity-sleep patterns of the two series. The rhythmicity of potassium excretion (peaks at around 1400) was more irregular. The stable oscillations of mercury excretion contrasted most with the excretion of adrenaline and noradrenaline, which, without losing the basic 24-h rhythmicity, closely followed the unconventional patterns of activity and sleep.

  9. Determination of the absolute configuration of 2-hydroxyglutaric acid and 5-oxoproline in urine samples by high-resolution NMR spectroscopy in the presence of chiral lanthanide complexes.

    PubMed

    Bal, Dominika; Gradowska, Wanda; Gryff-Keller, Adam

    2002-06-15

    Determination of the absolute configuration of some metabolites in body fluids is important for the diagnosis of some inborn errors of metabolism. Presently available methods of such determinations are tedious and usually require highly specialized instrumentation. In this work, an alternative method, based on high-resolution nuclear magnetic resonance spectroscopy in the presence of the chiral lanthanide shift reagent as an auxiliary additive, has been proposed (NMR/LSR). The method involves the lineshape analysis of a chosen multiplet of the one-dimensional 1H NMR spectrum or application of the two-dimensional 1H-13C correlation spectroscopy (HSQC). In order to confirm the resonance assignments and to boost the signal-noise ratio, the addition of an amount of racemic analyte to the urine sample is recommended. The entire procedure is simple in application and demands minimal or no preprocessing of urine samples. The effectiveness of the method has been confirmed by finding the expected forms of 2-hydroxyglutaric acid and 5-oxoproline in the urine samples of an independently diagnosed patient with 2-D-hydroxyglutaric aciduria and 5-L-oxoprolinuria, respectively.

  10. Mutagenic activity and metabolites in the urine of workers exposed to trinitrotoluene (TNT).

    PubMed Central

    Ahlborg, G; Einistö, P; Sorsa, M

    1988-01-01

    Urine samples taken after work and after a free weekend from 50 workers employed in various activities in a chemical plant manufacturing explosives were analysed. On the basis of hygienic surveys, the subjects were divided into three categories of exposure to trinitrotoluene (TNT). The urine analyses consisted of gas chromatographic identification of TNT and its two metabolites, 4-ADNT and 2-ADNT, and a determination of the mutagenic activity. Two frame shift detector strains of Salmonella typhimurium were used, TA 98 and TA 98 NR, the latter being deficient in endogenous nitroreductase activity. On the basis of previous results on TNT mutagenicity, no exogeneous metabolic system was used to test the urine concentrates. Both tester strains showed that the mean urinary mutagenic activity was higher in the after work samples than in post weekend samples from the same subjects, showing that bacterial nitroreductase activity was not significantly responsible for the mutagenicity, although the response was higher with strain TA 98 than with TA 98 NR. The interindividual variation in urine mutagenicity was high, however, and the difference between the two sampling times was statistically significant (p less than 0.05) only for the high exposed group (workers in trotyl foundry and sieve house). Correlation between urinary mutagenicity and concentration of TNT in urine was poor; correlation was significant only with the urinary concentration of 4-ADNT. The correlation between urinary TNT and both metabolites was good (p less than 0.001). These results suggest that analysis of 4-ADNT in urine would be a sufficient biological measure for controlling exposure to TNT. PMID:3378017

  11. Seasonal variation in natural abundance of 2H and 18O in urine samples from rural Nigeria.

    PubMed

    Harbison, Justin E; Dugas, Lara R; Brieger, William; Tayo, Bamidele O; Alabi, Tunrayo; Schoeller, Dale A; Luke, Amy

    2015-07-01

    The doubly labeled water (DLW) method is used to measure free-living energy expenditure in humans. Inherent to this technique is the assumption that natural abundances of stable isotopes (2)H and (18)O in body water remain constant over the course of the measurement period and after elimination of the loading dose of DLW will return to the same predose level. To determine variability in the natural abundances of (2)H and (18)O in humans living in a region with seasonal shifts in rain patterns and sources of drinking water, over the course of 12 mo we collected weekly urine samples from four individuals living in southwest Nigeria as well as samples of their drinking water. From ongoing regional studies of hypertension, obesity, and energy expenditure, we estimated average water turnover rate, urine volumes, and sodium and potassium excretion. Results suggest that (2)H and (18)O in urine, mean concentrations of urinary sodium and potassium, urine volume, and total body turnover differed significantly from dry to rainy season. Additionally, seasonal weather variables (mean monthly maximum temperatures, total monthly rainfall, and minimum relative humidity) were all significantly associated with natural abundances in urine. No seasonal difference was observed in drinking water samples. Findings suggest that natural abundances in urine may not remain constant as assumed, and studies incorporating DLW measurements across the transition of seasons should interpret results with caution unless appropriate doses of the tracers are used. Copyright © 2015 the American Physiological Society.

  12. Associations between Bisphenol A Exposure and Reproductive Hormones among Female Workers

    PubMed Central

    Miao, Maohua; Yuan, Wei; Yang, Fen; Liang, Hong; Zhou, Zhijun; Li, Runsheng; Gao, Ersheng; Li, De-Kun

    2015-01-01

    The associations between Bisphenol-A (BPA) exposure and reproductive hormone levels among women are unclear. A cross-sectional study was conducted among female workers from BPA-exposed and unexposed factories in China. Women’s blood samples were collected for assay of follicle-stimulating hormone (FSH), luteinizing hormone (LH), 17β-Estradiol (E2), prolactin (PRL), and progesterone (PROG). Their urine samples were collected for BPA measurement. In the exposed group, time weighted average exposure to BPA for an 8-h shift (TWA8), a measure incorporating historic exposure level, was generated based on personal air sampling. Multiple linear regression analyses were used to examine linear associations between urine BPA concentration and reproductive hormones after controlling for potential confounders. A total of 106 exposed and 250 unexposed female workers were included in this study. A significant positive association between increased urine BPA concentration and higher PRL and PROG levels were observed. Similar associations were observed after the analysis was carried out separately among the exposed and unexposed workers. In addition, a positive association between urine BPA and E2 was observed among exposed workers with borderline significance, while a statistically significant inverse association between urine BPA and FSH was observed among unexposed group. The results suggest that BPA exposure may lead to alterations in female reproductive hormone levels. PMID:26506366

  13. Associations between Bisphenol A Exposure and Reproductive Hormones among Female Workers.

    PubMed

    Miao, Maohua; Yuan, Wei; Yang, Fen; Liang, Hong; Zhou, Zhijun; Li, Runsheng; Gao, Ersheng; Li, De-Kun

    2015-10-22

    The associations between Bisphenol-A (BPA) exposure and reproductive hormone levels among women are unclear. A cross-sectional study was conducted among female workers from BPA-exposed and unexposed factories in China. Women's blood samples were collected for assay of follicle-stimulating hormone (FSH), luteinizing hormone (LH), 17β-Estradiol (E2), prolactin (PRL), and progesterone (PROG). Their urine samples were collected for BPA measurement. In the exposed group, time weighted average exposure to BPA for an 8-h shift (TWA8), a measure incorporating historic exposure level, was generated based on personal air sampling. Multiple linear regression analyses were used to examine linear associations between urine BPA concentration and reproductive hormones after controlling for potential confounders. A total of 106 exposed and 250 unexposed female workers were included in this study. A significant positive association between increased urine BPA concentration and higher PRL and PROG levels were observed. Similar associations were observed after the analysis was carried out separately among the exposed and unexposed workers. In addition, a positive association between urine BPA and E2 was observed among exposed workers with borderline significance, while a statistically significant inverse association between urine BPA and FSH was observed among unexposed group. The results suggest that BPA exposure may lead to alterations in female reproductive hormone levels.

  14. Acute suppression of serum IgM and IgA in tank workers exposed to benzene.

    PubMed

    Kirkeleit, J; Ulvestad, E; Riise, T; Bråtveit, M; Moen, B E

    2006-12-01

    We investigated associations between benzene exposure and alterations of proteins and cells of the immune system among workers maintaining cargo tanks containing crude oil residues. Individual exposure to benzene, benzene in blood and urine, peripheral blood lymphocytes (total lymphocytes, lymphocytes in subpopulations CD3, CD4, CD8, CD19, CD56 and CD4/CD8 ratio), complement factors C3 and C4 and serum concentration of immunoglobulins (IgG, IgA, IgM and IgE) were analysed among 13 tank workers and nine unexposed referents (catering section). Benzene exposure was measured during three consecutive 12-h work days. Blood and urine samples were collected pre-shift on the first day (baseline), post-shift on the third day, and pre-next shift on the following morning. The time spent in the cargo tank was logged. The individual geometric mean benzene exposure in the breathing zone of tank workers over 3 days was 0.15 p.p.m. (range 0.01-0.62 p.p.m.) (n = 26). The geometric mean benzene concentration in blood post-shift was 12.3 nmol/l among tank workers versus 0.7 nmol/l among the referents. Tank workers showed a decline (versus referents) in IgM from baseline to post-shift (t-test, P = 0.04) and IgA from baseline to pre-next shift (t-test, P = 0.01). They also showed a decline in CD4 T cells from baseline to post-shift (t-test, P = 0.04). Suppression correlated with benzene exposure, benzene concentrations in blood and urine and time spent in the tank. The groups did not differ significantly in the change in other immune parameters. The clinical significance is unknown and warrants further studies.

  15. Biomonitoring short- and long-term exposure to the herbicide terbuthylazine in agriculture workers and in the general population using urine and hair specimens.

    PubMed

    Mercadante, Rosa; Polledri, Elisa; Bertazzi, Pier Alberto; Fustinoni, Silvia

    2013-10-01

    The aim of this work was to evaluate short-term and long-term exposure to terbuthylazine (TBA) in agriculture workers (AW), rural residents (RR), and urban residents (UR) using urine and hair specimens. Twelve AW, 13 RR, and 17 UR were included in the study. Urine spot samples were collected with two different protocols. AW urine samples were collected before the application season (February, U0), at bedtime on the day of TBA application (March-May, U1), and prior to the next shift on the day after TBA application (U2). RR and UR urine samples were collected on any day during the application season (Ue). Hair samples were collected for all subjects before the application season (February, H0) and at the end of the season (June, H1). TBA and its metabolite desethylterbuthylazine (DET) were measured by liquid chromatography coupled with triple quadrupole mass spectrometry detection. DET was exclusively found in urine, while TBA was mostly found in the hair. In the AW, the urinary levels of DET were not detected in the U0 samples, and they increased to median levels of 1.81 and 2.94μg/L in the U1 and U2 samples, respectively (p<0.001). In the RR and UR, DET was not detected in the Ue samples. In the UR, TBA was not detected in the H0 samples, and the median levels of TBA were 0.01ng/mg hair in both the AW and RR. In the H1 samples, the median TBA levels were not detected, 0.01, and 0.08ng/mg hair in the UR, RR, and AW, respectively (p<0.001). Urinary DET and hair TBA are promising candidates for biomonitoring short- and long-term exposure to TBA. The use of this herbicide in agriculture leads to exposure in rural residents. © 2013.

  16. SERS quantitative urine creatinine measurement of human subject

    NASA Astrophysics Data System (ADS)

    Wang, Tsuei Lian; Chiang, Hui-hua K.; Lu, Hui-hsin; Hung, Yung-da

    2005-03-01

    SERS method for biomolecular analysis has several potentials and advantages over traditional biochemical approaches, including less specimen contact, non-destructive to specimen, and multiple components analysis. Urine is an easily available body fluid for monitoring the metabolites and renal function of human body. We developed surface-enhanced Raman scattering (SERS) technique using 50nm size gold colloidal particles for quantitative human urine creatinine measurements. This paper shows that SERS shifts of creatinine (104mg/dl) in artificial urine is from 1400cm-1 to 1500cm-1 which was analyzed for quantitative creatinine measurement. Ten human urine samples were obtained from ten healthy persons and analyzed by the SERS technique. Partial least square cross-validation (PLSCV) method was utilized to obtain the estimated creatinine concentration in clinically relevant (55.9mg/dl to 208mg/dl) concentration range. The root-mean square error of cross validation (RMSECV) is 26.1mg/dl. This research demonstrates the feasibility of using SERS for human subject urine creatinine detection, and establishes the SERS platform technique for bodily fluids measurement.

  17. Proposal for single and mixture biological exposure limits for sevoflurane and nitrous oxide at low occupational exposure levels.

    PubMed

    Accorsi, Antonio; Valenti, Simona; Barbieri, Anna; Raffi, Giovanni Battista; Violante, Francesco Saverio

    2003-03-01

    Assessment of individual exposures to sevoflurane plus nitrous oxide (N(2)O) by biological monitoring of unmodified analytes in post-shift urine of exposed personnel. Anaesthetics in urine and breathing area were monitored in 124 subjects in 11 operating theatres. Passive samplers were collected after 2.5-7 h of exposure, at the same time as post-shift urinary samples, to evaluate the individual time-weighted average (TWA) exposures to sevoflurane and N(2)O. A static headspace sampler coupled with a gas chromatograph mass spectrometer was used for analytical determinations (sensitivity sufficient to reveal biological/environmental exposures of 0.1 microg/l(urine) and 50 ppb for sevoflurane, and 1 microg/l(urine) and 80 ppb for N(2)O). Median (range) post-shift urinary and environmental values were 1.2 microg/l(urine) (0.1-5.0) and 0.4 ppm (0.05-3.0) for sevoflurane ( n=107) and 10.9 microg/l(urine) (0.5-74.9) and 8.6 ppm (0.2-123.4) for N(2)O ( n=121) (all low-exposure range). At log-log regression, urinary levels closely correlated with environmental data (sevoflurane, r(2)=0.7538; N(2)O, r(2)=0.8749). Biological equivalent limits (BELs) based on National Institute for Occupational Safety and Health (NIOSH) TWA exposure limits, calculated as means of regression slope and y-intercept, were 3.6 microg/l(urine) for sevoflurane (corresponding to 2 ppm) and 22.3 microg/l(urine) for N(2)O (corresponding to 25 ppm). Individual "mixture BELs", which we calculated by applying the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) mix formula to biomarker values and using the obtained NIOSH-based BELs as a reference, closely correlated with mixture TLVs (rho=0.816, Lin's concordance test). CONCLUSIONS. We propose urinary sevoflurane as a new, specific, internal dose biomarker for routine biological monitoring of personal exposures among operating-theatre personnel, and use of reliable "mixture BELs" to provide safer levels of internal exposure for workers exposed to mixtures of sevoflurane and N(2)O, and conceivably also to other mixtures of toxicants with possible additive effects.

  18. Effect of different exposure compounds on urinary kinetics of aluminium and fluoride in industrially exposed workers.

    PubMed Central

    Pierre, F; Baruthio, F; Diebold, F; Biette, P

    1995-01-01

    OBJECTIVE--To conduct a field study to obtain information on the urinary concentrations of aluminium (Al) and fluoride (F-) depending on the different compounds exposed to in the aluminum industry. METHODS--16 workers from one plant that produced aluminium fluoride (AlF3), and from two plants that produced aluminium electrolytically by two different processes participated in the study for one working week. Pollutants were monitored by eight hour personal sampling every day, and urine samples were collected during the week. Al and F- were analysed in both atmospheric and urine samples by atomic absorption spectrometry and an ion selective electrode. RESULTS--The principal results show different characteristics of kinetic curves of Al and F- excretion in workers with different exposures. Some characteristics of excretory peaks were linked to specific exposures--for instance, after exposure to AlF3 there was one delayed Al peak associated with one delayed F- peak about eight hours after the end of the daily shift, and after mixed exposure to HF and AlF3, two F- peaks were noted, one fast peak at the end of the shift and another delayed peak at 10 hours synchronised with an Al peak. In one of the electrolysis plants, the exposure to Al and F- compounds led to the simultaneous excretion of Al and F- peaks, either as a single peak or two individual ones depending on the type of technology used on site (open or enclosed potlines). The average estimated half life of Al was 7.5 hours, and of F- about nine hours. Quantitative relations between excretion and exposure showed an association between the F- atmospheric limit value of 2.5 mg/m3 with a urinary F- concentration of 6.4 mg/g creatinine at the end of the shift, a peak of 7.4 mg/g creatinine, and 7.4 mg excreted a day. For Al, the exposure to 1.36 mg/m3 during the shift corresponded to a urinary concentration at the end of the shift of 200 microgram/g creatinine. Daily excretion of 200 micrograms corresponded to an exposure to 0.28 mg/m3. CONCLUSION--Particular differences in the behaviour of Al and F- in urine depended upon the original molecular form in the pollutant. These results reinforce the principle that, in biological monitoring, the sampling strategy and the choice of limit value should be dependent on kinetic data that take the exposure compound of the element in question into account. PMID:7627317

  19. Zinc exposure for female workers in a galvanizing plant in Northern Italy.

    PubMed

    Riccò, Matteo; Cattani, Silvia; Signorelli, Carlo

    2018-01-01

    Very little is known regarding the toxicokinetics of inhaled zinc, in particular in the case of female workers and for modern, low exposure settings. Our aim is to evaluate the relationship of external zinc levels to those of serum and urine for female workers. Eleven female workers (age: 41.7±8 years old, body mass index (BMI): 23.5±4.2 kg/m2) in a galvanizing plant were investigated. Exposure assessment consisted of personal/environmental air samples, and measurement of zinc in serum (collected at the end of first shift of the working week (T1)) and urine, collected before the first shift of the working week (T0), T1 and at the end of the last shift of the working week (T2). Both environmental and personal air samplings for zinc and zinc compounds were below the recommended by the German Research Foundation (Deutsche Forschungsgemeinschaft - DFG) limit values of 2 mg/m3 (7.34±2.8 μg/m3 and 8.31±2.4 μg/ m3, respectively). Serum (118.6±20.9 μg /dl) and urine zinc levels were within reference values for female Italian subjects: the latter increased from 56.4±33.5 μg/dl at T0, to 59.8±37.0 μg/dl at T1, and ultimately 65.4±34.4 μg/dl at T2, but no significant trend was found. End of shift (Spearman's correlation coefficient p value = 0.027) and differential excretion of urinary zinc (both: T0 vs. T1 and T0 vs. T2) were correlated with airborne zinc concentration (p = 0.002 and 0.006, respectively). In general, our data suggests that urine may be a useful medium also for female in order to assess zinc exposure. Further studies are required in order to evaluate whether differential excretion may be useful for the biomonitoring of zinc exposure in the workplaces also for male workers. Int J Occup Med Environ Health 2018;31(1):113-124. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  20. Certain aspects of human metabolism during spaceflights of varying duration

    NASA Technical Reports Server (NTRS)

    Grigoryev, A. I.; Popova, I. A.; Ushakov, A. S.

    1988-01-01

    A comparative analysis is made of hormone reactions after short and long term spaceflights. Endocrinological indicators from venous blood and daily urine samples of cosmonauts completing flights lasting from 7 to 237 days were examined. No pathological indicators were found in the metabolic shifts in the erythrocytes and disruption of the functional state of their membranes.

  1. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    PubMed

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Coupled brain and urine spectroscopy - in vivo metabolomic characterization of HMG-CoA lyase deficiency in 5 patients.

    PubMed

    Roland, Dominique; Jissendi-Tchofo, Patrice; Briand, Gilbert; Vamecq, Joseph; Fontaine, Monique; Ultré, Vincent; Acquaviva-Bourdain, Cécile; Mention, Karine; Dobbelaere, Dries

    2017-06-01

    3-Hydroxy-3-Methylglutaryl-Coenzyme A (HMG-CoA) lyase deficiency is a rare inborn error of leucine metabolism and ketogenesis. Despite recurrent hypoglycemia and metabolic decompensations, most patients have a good clinical and neurological outcome contrasting with abnormal brain magnetic resonance imaging (MRI) signals and consistent abnormal brain proton magnetic resonance spectroscopy ( 1 H-MRS) metabolite peaks. Identifying these metabolites could provide surrogate markers of the disease and improve understanding of MRI-clinical discrepancy and follow-up of affected patients. Urine samples, brain MRI and 1 H-MRS in 5 patients with HMG-CoA lyase deficiency (4 boys and 1 girl aged from 25days to 10years) were, for each patient, obtained on the same day. Brain and urine spectroscopy were performed at the same pH by studying urine at pH 7.4. Due to pH-induced modifications in chemical shifts and because reference 1 H NMR spectra are obtained at pH 2.5, spectroscopy of normal urine added with the suspected metabolite was further performed at this pH to validate the correct identification of compounds. Mild to extended abnormal white matter MRI signals were observed in all cases. Brain spectroscopy abnormal peaks at 0.8-1.1ppm, 1.2-1.4ppm and 2.4ppm were also detected by urine spectroscopy at pH 7.4. Taking into account pH-induced changes in chemical shifts, brain abnormal peaks in patients were formally identified to be those of 3-hydroxyisovaleric, 3-methylglutaconic, 3-methylglutaric and 3-hydroxy-3-methylglutaric acids. 3-Methylglutaric, 3-hydroxyisovaleric and 3-hydroxy-3-methylglutaric acids identified on urine 1 H-NMR spectra of 5 patients with HMG-CoA lyase deficiency are responsible for the cerebral spectroscopy signature seen in these patients, validating their local involvement in brain and putative contribution to brain neuropathology. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Exposure to hexavalent chromium in welders: Results of the WELDOX II field study.

    PubMed

    Pesch, Beate; Lehnert, Martin; Weiss, Tobias; Kendzia, Benjamin; Menne, Eleonore; Lotz, Anne; Heinze, Evelyn; Behrens, Thomas; Gabriel, Stefan; Schneider, Wolfgang; Brüning, Thomas

    2018-03-12

    Exposure to hexavalent chromium (Cr(VI)) has been primarily studied in chromate production. Here, we measured personal exposure to respirable Cr(VI) together with airborne and urinary Cr and Ni in welders to explore levels and associations between various measures of exposure. Shift concentrations of Cr(VI), Cr, and Ni were measured in respirable welding fumes in 50 men who used either gas metal arc welding (GMAW) (n = 24) or tungsten inert gas welding (TIG) (n = 19) as their major technique. Cr and Ni were determined in pre- and post-shift urine samples. Concentrations below the limit of quantification (LOQ) were multiply imputed. Spearman correlation coefficients (rs) were calculated with 95% confidence intervals (CIs) to explore associations between the exposure variables, and regression models were applied to estimate the effect of the parent metal on the urinary concentration. Regarding the respirable Cr(VI), 62% of the measurements were below the LOQ, the 75th percentile was 0.50 µg m-3, and 8 out of 50 (16%) welders exceeded 1 µg m-3. The highest shift concentration that occurred as a result of shielded metal arc welding (SMAW) was 180 µg m-3. The Cr(VI) content in total Cr ranged from 4 to 82% (median 20%), although the concentration correlated with total Cr (rs 0.55, 95% CI 0.46; 0.64). The correlation between Cr(VI) and Ni was weaker (rs 0.42, 95% CI 0.34; 0.51) than that between total Cr and Ni in welding fumes (rs 0.83, 95% CI 0.74; 0.92). Both Cr(VI) and total Cr influenced the urinary Cr concentrations in post-shift samples (P = 0.0008 and P ≤ 0.0001, respectively). The airborne shift exposure was a weaker determinant than the Cr content in pre-shift urine samples, which strongly correlated with post-shift urinary Cr (rs 0.78, 95% CI 0.69; 0.87). The Cr(VI) content in total Cr varied considerably in welding fumes. The majority of welders using GMAW or TIG presented with shift concentrations of respirable Cr(VI) below 1 µg m-3. However, very high Cr(VI) concentrations may occur, for example in SMAW. The urinary concentration of total Cr, cannot be used to precisely determine the shift concentration of respirable Cr(VI) in welders.

  4. Evaluation of Occupational Exposure of Glazers of a Ceramic Industry to Cobalt Blue Dye

    PubMed Central

    KARGAR, Fatemeh; SHAHTAHERI, Seyed Jamaleddin; GOLBABAEI, Farideh; BARKHORDARI, Abolfazl; RAHIMI-FROUSHANI, Abbas; KHADEM, Monireh

    2013-01-01

    Background: Cobalt is one of the most important constituent present in ceramic industries. Glazers are the relevant workers when they are producing blue colored ceramic, causing occupational exposure to such metal. Through this study, urinary cobalt was determined in glazers in a ceramic industry when they were producing blue-colored ceramic glazes. Methods: In this case-control study, spot urine samples were collected from 49 glazers at the start and end of work shifts (totally 98 samples) in 2011. Control group were well matched for age, height, and weight. A solid phase extraction system was used for separation and preconcentration of samples followed by analysis by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). All participants filled out a self administered questionnaire comprises questions about duration of exposure, work shift, use of mask, skin dermatitis, kind of job, ventilation system, overtime work, age, weight, and height. The lung function tests were performed on each control and cobalt exposed subjects. Analysis of covariance (ANCOVA) was used to evaluate the obtained results. Results: Urinary levels of cobalt were significantly higher in the glazers compared to the control group. There were significant differences at urinary concentration of cobalt at the start and end of the work shift in glazers. Spirometric parameters were significantly lower in the glazers compared to the control group. Among the variables used in questionnaire the significant variables were dermatitis skin, mask, ventilation, and overtime work. Conclusion: This study verified existence of cobalt in the urine glazers, showing lower amount than the ACGIH standard. PMID:26056641

  5. Urinary hydroxy-metabolites of naphthalene, phenanthrene and pyrene as markers of exposure to diesel exhaust.

    PubMed

    Kuusimäki, Leea; Peltonen, Yrjö; Mutanen, Pertti; Peltonen, Kimmo; Savela, Kirsti

    2004-01-01

    The objective of this study was to assess the exposure of bus-garage and waste-collection workers to polycyclic aromatic hydrocarbons (PAHs) derived from diesel exhaust by the measurement of levels of seven urinary PAH metabolites: 2-naphthol, 1-hydroxyphenanthrene, 2-hydroxyphenanthrene, 3-hydroxyphenanthrene, 1+9-hydroxyphenanthrene, 4-hydroxyphenanthrene and 1-hydroxypyrene. One urine sample from each of 46 control persons, and one pre-shift and two post-shift spot urine samples from 32 exposed workers were obtained in winter and in summer. The metabolites were analysed after enzymatic hydrolysis by high performance liquid chromatography (HPLC) with fluorescence detection. The sum of seven PAH metabolites (mean 3.94 +/- 3.40 and 5.60 +/- 6.37 micromol/mol creatinine in winter and summer, respectively) was higher [P=0.01, degrees of freedom (df) =61.2 and P=0.01, df=67.6 in winter and summer, respectively] in the exposed group than in the control group (mean 3.18 +/- 3.99 and 3.03 +/- 2.01 micromol/mol creatinine in winter and summer, respectively). The mean concentrations of 2-naphthol among exposed and controls ranged between 3.34 and 4.85 micromol/mol creatinine and 2.51 and 2.58 micromol/mol creatinine, respectively (P<0.01 in winter, P<0.03 in summer). The mean level of the hydroxyphenanthrenes in the samples of exposed workers was between 0.40 and 0.70 micromol/mol creatinine and in the control samples 0.40-0.60 micromol/mol creatinine. The concentration of 1-hydroxypyrene was higher among exposed workers in both pre-shift and post-shift samples (mean 0.10-0.15 micromol/mol creatinine) than in control group (mean 0.05-0.06 micromol/mol creatinine) in winter (P=0.002, df=78) and in summer (P<0.001, df=68). The urinary hydroxy-metabolites of naphthalene, phenanthrene and pyrene showed low exposure to diesel-derived PAHs; however, it was higher in exposed workers than in control group. Urinary PAH monohydroxy-metabolites measured in this study did not correlate with the PAHs in the air samples, reported earlier, in 2002 and 2003.

  6. Occupational exposure to bisphenol A (BPA) in a plastic injection molding factory in Malaysia.

    PubMed

    Kouidhi, Wided; Thannimalay, Letchumi; Soon, Chen Sau; Ali Mohd, Mustafa

    2017-07-14

    The purpose of this study has been to assess ambient bisphenol A (BPA) levels in workplaces and urine levels of workers and to establish a BPA database for different populations in Malaysia. Urine samples were collected from plastic factory workers and from control subjects after their shift. Air samples were collected using gas analyzers from 5 sampling positions in the injection molding unit work area and from ambient air. The level of BPA in airborne and urine samples was quantified by the gas chromatography mass spectrometry - selected ion monitoring (GCMS-SIM) analysis. Bisphenol A was detected in the median range of 8-28.3 ng/m³ and 2.4-3.59 ng/m³ for the 5 sampling points in the plastic molding factory and in the ambient air respectively. The median urinary BPA concentration was significantly higher in the workers (3.81 ng/ml) than in control subjects (0.73 ng/ml). The urinary BPA concentration was significantly associated with airborne BPA levels (ρ = 0.55, p < 0.01). Our findings provide the first evidence that workers in a molding factory in Malaysia are occupationally exposed to BPA. Int J Occup Med Environ Health 2017;30(5):743-750. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  7. Hippuric Acid Levels in Paint Workers at Steel Furniture Manufacturers in Thailand

    PubMed Central

    Decharat, Somsiri

    2014-01-01

    Background The aims of this study were to determine hippuric acid levels in urine samples, airborne toluene levels, acute and chronic neurological symptoms, and to describe any correlation between urinary hippuric acid and airborne toluene. Methods The hippuric acid concentration in the urine of 87 paint workers exposed to toluene at work (exposed group), and 87 nonexposed people (control group) was studied. Study participants were selected from similar factories in the same region. Urine samples were collected at the end of a shift and analyzed for hippuric acid by high performance liquid chromatography. Air samples for the estimation of toluene exposure were collected with diffusive personal samplers and the toluene quantified using gas–liquid chromatography. The two groups were also interviewed and observed about their work practices and health. Results The median of the 87 airborne toluene levels was 55 ppm (range, 12–198 ppm). The median urinary hippuric acid level was 800 mg/g creatinine (range, 90–2547 mg/g creatinine). A statistically significant positive correlation was found between airborne toluene exposure and urine hippuric acid levels (r = 0.548, p < 0.01). Workers with acute symptoms had significantly higher hippuric acid levels than those who did not (p < 0.05). It was concluded that there was a significant correlation between toluene exposure, hippuric acid levels, and health (p < 0.001). Conclusion There appears to be a significant correlation between workers exposure to toluene at work, their urine hippuric acid levels, and resulting symptoms of poor health. Improvements in working conditions and occupational health education are required at these workplaces. There was good correlation between urinary hippuric acid and airborne toluene levels. PMID:25516817

  8. Advances in the Diagnosis of Human Opisthorchiasis: Development of Opisthorchis viverrini Antigen Detection in Urine

    PubMed Central

    Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.

    2015-01-01

    Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024

  9. Urinary nickel as bioindicator of workers' Ni exposure in a galvanizing plant in Brazil.

    PubMed

    Oliveira, J P; de Siqueira, M E; da Silva, C S

    2000-01-01

    We measured urinary nickel (U-Ni) in ten workers (97 samples) from a galvanizing plant that uses nickel sulfate, and in ten control subjects (55 samples) to examine the association between occupational exposure to airborne Ni and Ni absorption. Samples from the exposed group were taken before and after the work shift on 5 successive workdays. At the same time airborne Ni (A-Ni) was measured using personal samplers. Ni levels in biological material and in the airborne were determined by a graphite furnace atomic absorption spectrometry validated method. In the control group the urine samples were collected twice a day, in the before and after the work shift, on 3 successive days. Ni exposure low to moderate was detected in all the examined places in the plant, the airborne levels varying between 2.8 and 116.7 micrograms/m3 and the urine levels, from samples taken postshift, between 4.5 and 43.2 micrograms/g creatinine (mean 14.7 micrograms/g creatinine). Significant differences in U-Ni creatinine were seen between the exposed and control groups (Student's t test, P < or = 0.01). A significant correlation between U-Ni and A-Ni (r = 0.96; P < or = 0.001) was detected. No statistical difference was observed in U-Ni collected from exposed workers in the 5 successive days, but significant difference was observed between pre- and postshift samples. Urinary nickel may be used as a reliable internal dose bioindicator in biological monitoring of workers exposed to Ni sulfate in galvanizing plants regardless of the day of the workweek on which the samples are collected.

  10. Correlation between urinary methoxyacetic acid and exposure of ethylene glycol dimethyl ether in a lithium battery plant.

    PubMed

    Yokota, Kozo; Ueno, Hiroshi; Ikeda, Naoko; Johyama, Yasushi; Michitsuji, Hiromi; Yamada, Seiji

    2007-10-01

    To examine the correlation between airborne ethylene glycol dimethyl ether (EGdiME) exposures and the urinary methoxyacetic acid (MAA) and to approach the issue of a permissible exposure limit for EGdiME. The survey was conducted on Thursday. Workers occupationally exposed to EGdiME, as well as nonexposed controls, were studied in combination with one of the authors, who was coincidentally exposed to EGdiME while carrying out the study. Air levels of EGdiME were determined by personal sampling on passive gas tubes. Urine was collected from nine control subjects and ten workers immediately before and after the shift, and from one of the authors at intervals during 12 h. The analyses of EGdiME in air and MAA in urine were performed by gas chromatography with flame ionization detection. The time-weighted average (TWA) air levels of EGdiME ranged from 0.7 to 10.5 ppm during 8 h work shifts. The urinary levels of MAA in one of the authors increased continuously during exposure and after the end of exposure. The levels of urinary MAA in the exposed workers were significantly higher than those in the control subjects. On the other hand, the postshift values were higher than the preshift values in the exposed workers, but the difference was not significant. A linear correlation was found between the TWA air levels of EGdiME and creatinine-adjusted MAA levels in urine collected at the end of the shift (r = 0.933; P < 0.0001). According to our equation, a linear extrapolation to the biological limit value recommended by Shih et al. (1999) of 40 mg MAA/g crea indicated an average inhalation exposure to EGdiME over the workweek of 12 ppm. These results indicate that the determination of MAA in urine is suitable for use in the biological monitoring of EGdiME exposure.

  11. The Paris System for Reporting Urinary Cytology: The Quest to Develop a Standardized Terminology.

    PubMed

    Barkan, Güliz A; Wojcik, Eva M; Nayar, Ritu; Savic-Prince, Spasenija; Quek, Marcus L; Kurtycz, Daniel F I; Rosenthal, Dorothy L

    2016-07-01

    The main purpose of urine cytology is to detect high-grade urothelial carcinoma. With this principle in mind, The Paris System (TPS) Working Group, composed of cytopathologists, surgical pathologists, and urologists, has proposed and published a standardized reporting system that includes specific diagnostic categories and cytomorphologic criteria for the reliable diagnosis of high-grade urothelial carcinoma. This paper outlines the essential elements of TPS and the process that led to the formation and rationale of the reporting system. TPS Working Group, organized at the 2013 International Congress of Cytology, conceived a standardized platform on which to base cytologic interpretation of urine samples. The widespread dissemination of this approach to cytologic examination and reporting of urologic samples and the scheme's universal acceptance by pathologists and urologists is critical for its success. For urologists, understanding the diagnostic criteria, their clinical implications, and limitations of TPS is essential if they are to utilize urine cytology and noninvasive ancillary tests in a thoughtful and practical manner. This is the first international/inclusive attempt at standardizing urinary cytology. The success of TPS will depend on the pathology and urology communities working collectively to improve this seminal paradigm shift, and optimize the impact on patient care.

  12. An assessment of occupational exposure to polycyclic aromatic hydrocarbons in the UK.

    PubMed

    Unwin, John; Cocker, John; Scobbie, Emma; Chambers, Helen

    2006-06-01

    A cross-industry occupational hygiene survey was commissioned by the Health and Safety Executive (HSE) to determine the levels of polycyclic aromatic hydrocarbon (PAH) exposure in UK industry and to determine if one or more target analytes were suitable as markers for assessing total exposure to PAHs. There were no broadly applicable UK exposure standards for assessing total exposure to PAHs. Until 1993 a guidance value for assessing exposure in coke ovens only, where PAH exposure is known to be the highest, was based on gravimetric analysis of cyclohexane-soluble material. Biological monitoring based on urinary 1-hydroxypyrene (1-OHP) is widely reported to be an effective indicator of exposure by both dermal and inhalation routes but there was no UK guidance value. The survey involved an occupational hygiene study of 25 sites using both airborne monitoring of a total of 17 individual PAHs and biological monitoring. The results showed 8 h TWA levels of total PAH in air ranged from 0.4 to 1912.6 microg m(-3) with a GM of 15.8 microg m(-3). The profile of PAHs was dominated by naphthalene, the most volatile 2-ring PAH. Airborne benzo(a)pyrene (BaP) correlated well (r(2) = 0.971) with levels of carcinogenic 4-6 ring PAHs and was an effective marker of exposure for all industries where significant particle bound PAH levels were found and, in particular, for CTPV exposure. The 8 h TWA levels of BaP ranged from <0.01 to 6.21 microg m(-3) with a GM of 0.036 microg m(-3); 90% were <0.75 microg m(-3) and 95% were <2.0 microg m(-3). Two hundred and eighteen urine samples collected from different workers at the end of shift and 213 samples collected pre-shift next day were analysed for 1-OHP. Levels of 1-OHP in end-of-shift samples were generally higher than those in pre-shift-next-day samples and showed a good correlation (r(2) = 0.768) to airborne BaP levels if samples from workers using respiratory protection or with significant dermal exposure were excluded. Urinary 1-OHP in end-of-shift samples ranged from the limit of detection (0.5 micromol mol(-1) creatinine) to 60 micromol mol(-1) creatinine with a mean of 2.49 micromol mol(-1) and a 90th percentile value of 6.7 micromol mol(-1) creatinine. The highest 1-OHP levels were found in samples from workers impregnating timber with creosote where exposure was dominated by naphthalene. If the 11 samples from these workers were excluded from the dataset, the 90% value for end-of-shift urine samples was 4 micromol mol(-1) creatinine (n = 207) and this value has since been adopted by the HSE as a biological monitoring benchmark value.

  13. Shift work parameters and disruption of diurnal cortisol production in female hospital employees.

    PubMed

    Hung, Eleanor Wai Man; Aronson, Kristan J; Leung, Michael; Day, Andrew; Tranmer, Joan

    2016-01-01

    Shift work is associated with an increased risk of cardiovascular diseases (CVD). Disruption of cortisol production is a potential underlying mechanism. This study explored the associations of diurnal quantity and pattern of cortisol production in relation to (1) current shift work status (exclusive day versus rotating days and nights), (2) years of past shift work and (3) parameters of rotating shift work (timing, length and intensity). Female hospital employees (160 day workers and 168 rotating shift workers) from southeastern Ontario, Canada, participated in a cross-sectional study. Participants completed a baseline questionnaire and measures of body height, weight, and waist circumference were taken. Midstream urine samples were collected over two separate 24-hour periods to measure creatinine-adjusted cortisol. Total diurnal cortisol production and pattern were described with two measures of the area under the curve. The effect of shift work on cortisol was modeled using multivariable linear regression analyses. Cortisol production in day workers and shift workers on their day shift were similar; however, shift workers on the night shift had flatter diurnal cortisol curves and produced less cortisol. This suggests that night work is associated with an acute attenuation of cortisol production.

  14. A retention-time-shift-tolerant background subtraction and noise reduction algorithm (BgS-NoRA) for extraction of drug metabolites in liquid chromatography/mass spectrometry data from biological matrices.

    PubMed

    Zhu, Peijuan; Ding, Wei; Tong, Wei; Ghosal, Anima; Alton, Kevin; Chowdhury, Swapan

    2009-06-01

    A retention-time-shift-tolerant background subtraction and noise reduction algorithm (BgS-NoRA) is implemented using the statistical programming language R to remove non-drug-related ion signals from accurate mass liquid chromatography/mass spectrometry (LC/MS) data. The background-subtraction part of the algorithm is similar to a previously published procedure (Zhang H and Yang Y. J. Mass Spectrom. 2008, 43: 1181-1190). The noise reduction algorithm (NoRA) is an add-on feature to help further clean up the residual matrix ion noises after background subtraction. It functions by removing ion signals that are not consistent across many adjacent scans. The effectiveness of BgS-NoRA was examined in biological matrices by spiking blank plasma extract, bile and urine with diclofenac and ibuprofen that have been pre-metabolized by microsomal incubation. Efficient removal of background ions permitted the detection of drug-related ions in in vivo samples (plasma, bile, urine and feces) obtained from rats orally dosed with (14)C-loratadine with minimal interference. Results from these experiments demonstrate that BgS-NoRA is more effective in removing analyte-unrelated ions than background subtraction alone. NoRA is shown to be particularly effective in the early retention region for urine samples and middle retention region for bile samples, where the matrix ion signals still dominate the total ion chromatograms (TICs) after background subtraction. In most cases, the TICs after BgS-NoRA are in excellent qualitative correlation to the radiochromatograms. BgS-NoRA will be a very useful tool in metabolite detection and identification work, especially in first-in-human (FIH) studies and multiple dose toxicology studies where non-radio-labeled drugs are administered. Data from these types of studies are critical to meet the latest FDA guidance on Metabolite in Safety Testing (MIST). Copyright (c) 2009 John Wiley & Sons, Ltd.

  15. Occupational exposure to airborne mercury during gold mining operations near El Callao, Venezuela.

    PubMed

    Drake, P L; Rojas, M; Reh, C M; Mueller, C A; Jenkins, F M

    2001-04-01

    The National Institute for Occupational Safety and Health (NIOSH) recently conducted a cross-sectional study during gold mining operations near El Callao, Venezuela. The purpose of the study was to assess mercury exposures and mercury-related microdamage to the kidneys. The study consisted of concurrent occupational hygiene and biological monitoring, and an examination of the processing techniques employed at the different mining facilities. Mercury was used in these facilities to remove gold by forming a mercury-gold amalgam. The gold was purified either by heating the amalgam in the open with a propane torch or by using a small retort. Thirty-eight workers participated in this study. Some participants were employed by a large mining company, while others were considered "informal miners" (self-employed). Mercury exposure was monitored by sampling air from the workers' breathing zones. These full-shift air samples were used to calculate time-weighted average (TWA) mercury exposure concentrations. A questionnaire was administered and a spot urine sample was collected. Each urine sample was analyzed for mercury, creatinine, and N-acetyl-beta-D-glucosaminidase (NAG). The range for the 8-h TWA airborne mercury exposure concentrations was 0.1 to 6,315 micrograms/m3, with a mean of 183 micrograms/m3. Twenty percent of the TWA airborne mercury exposure measurements were above the NIOSH recommended exposure limit (REL) of 50 micrograms/m3, and 26% exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) of 25 micrograms/m3. The mean urine mercury concentration was 101 micrograms/g creatinine (microgram/g-Cr), and the data ranged from 2.5 to 912 micrograms/g-Cr. Forty-two percent of the study participants had urine mercury concentrations that exceeded the ACGIH biological exposure index (BEI) of 35 micrograms/g-Cr. Urinary NAG excretion is considered a biological marker of preclinical, nonspecific microdamage to the kidney's proximal tubule cells. The mean urine NAG concentration was 3.6 International Units/g-Cr (IU/g-Cr) with a range of 0.5 to 11.5 IU/g-Cr. Three workers had urine NAG levels in excess of the reference values. Correlation analyses found statistically significant correlations between airborne mercury exposure and urine mercury level (P = 0.01), and between urine mercury level and urine NAG excretion (P = 0.01). In addition, the airborne mercury exposure data and urine mercury data were segregated by job tasks. A Wilcoxon rank sum test revealed significant correlations between tasks and mercury exposure (P = 0.03), and between tasks and urine mercury level (P = 0.02). The tasks with the highest mean airborne mercury exposures were "burning the mercury-gold amalgam" and "gold refining/smelting". Recommendations were provided for improving the retort design to better contain mercury, for ventilation in the gold shops, and for medical surveillance and educational programs.

  16. Biological monitoring of smoke exposure among wildland firefighters: A pilot study comparing urinary methoxyphenols with personal exposures to carbon monoxide, particulate matter, and levoglucosan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neitzel, R.; Naeher, L., P.; Paulsen, M.

    2009-04-01

    Urinary methoxyphenols (MPs) have been proposed as biomarkers of woodsmoke exposure. However, few field studies have been undertaken to evaluate the relationship between woodsmoke exposure and urinary MP concentrations. We conducted a pilot study at the US Forest ServiceFSavannah River Site, in which carbon monoxide (CO), levoglucosan (LG), and particulate matter (PM2.5) exposures were measured in wildland firefighters on prescribedburn days. Pre- and post-shift urine samples were collected from each subject, and cross-shift changes in creatinine-corrected urinary MP concentrations were calculated. Correlations between exposure measures and creatine-adjusted urinary MP concentrations were explored, and regression models were developed relating changes inmore » urinary MP concentrations to measured exposure levels. Full-shift measurements were made on 13 firefighters over 20 work shifts in winter 2004 at the US Forest Service Savannah River site, a National Environmental Research Park. The average workshift length across the 20 measured shifts was 701±95 min. LG and CO exposures were significantly correlated for samples where the filter measurement captured at least 60% of the work shift (16 samples), as well as for the smaller set of full-shift exposure samples (n¼9). PM2.5 and CO exposures were not significantly correlated, and LG and PM2.5 exposures were only significantly correlated for samples representing at least 60% of the work shift. Creatinine-corrected urinary concentrations for 20 of the 22 MPs showed cross-shift increases, with 14 of these changes showing statistical significance. Individual and summed creatinine-adjusted guaiacol urinary MPs were highly associated with CO (and, to a lesser degree, LG) exposure levels, and random-effects regression models including CO and LG exposure levels explained up to 80% of the variance in cross-shift changes in summed creatinine-adjusted guaiacol urinary MP concentrations. Although limited by the small sample size, this pilot study demonstrates that urinary MP concentrations may be effective biomarkers of occupational exposure to wood smoke among wildland firefighters.« less

  17. Biological monitoring of smoke exposure among wildland firefighters: Apilot study comparing urinary methoxyphenols with personal exposures to carbon monoxide, particulate matter, and levoglucosan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neitzel, R.; Naeher, L., P.; Paulsen, M.

    2009-04-01

    Urinary methoxyphenols (MPs) have been proposed as biomarkers of woodsmoke exposure. However, few field studies have been undertaken to evaluate the relationship between woodsmoke exposure and urinary MP concentrations. We conducted a pilot study at the US Forest Service Savannah River Site, in which carbon monoxide (CO), levoglucosan (LG), and particulate matter (PM2.5) exposures were measured in wildland firefighters on prescribed burn days. Pre- and post-shift urine samples were collected from each subject, and cross-shift changes in creatinine-corrected urinary MP concentrations were calculated. Correlations between exposure measures and creatine-adjusted urinary MP concentrations were explored, and regression models were developed relatingmore » changes in urinary MP concentrations to measured exposure levels. Full-shift measurements were made on 13 firefighters over 20 work shifts in winter 2004 at the US Forest Service Savannah River site, a National Environmental Research Park. The average workshift length across the 20 measured shifts was 701±95 min. LG and CO exposures were significantly correlated for samples where the filter measurement captured at least 60% of the work shift (16 samples), as well as for the smaller set of full-shift exposure samples (n¼9). PM2.5 and CO exposures were not significantly correlated, and LG and PM2.5 exposures were only significantly correlated for samples representing at least 60% of the work shift. Creatinine-corrected urinary concentrations for 20 of the 22 MPs showed cross-shift increases, with 14 of these changes showing statistical significance. Individual and summed creatinine-adjusted guaiacol urinary MPs were highly associated with CO (and, to a lesser degree, LG) exposure levels, and random-effects regression models including CO and LG exposure levels explained up to 80% of the variance in cross-shift changes in summed creatinine-adjusted guaiacol urinary MP concentrations. Although limited by the small sample size, this pilot study demonstrates that urinary MP concentrations may be effective biomarkers of occupational exposure to wood smoke among wildland firefighters.« less

  18. Biological monitoring of smoke exposure among wildland firefighters: A pilot study comparing urinary methoxyphenols with personal exposures to carbon monoxide, particulate matter, and levoglucosan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neitzel, R.; Naeher, L., P.; Paulsen, M.

    2009-04-01

    Urinary methoxyphenols (MPs) have been proposed as biomarkers of woodsmoke exposure. However, few field studies have been undertaken to evaluate the relationship between woodsmoke exposure and urinary MP concentrations. We conducted a pilot study at the US Forest Service Savannah River Site, in which carbon monoxide (CO), levoglucosan (LG), and particulate matter (PM2.5) exposures were measured in wildland firefighters on prescribed burn days. Pre- and post-shift urine samples were collected from each subject, and cross-shift changes in creatinine-corrected urinary MP concentrations were calculated. Correlations between exposure measures and creatine-adjusted urinary MP concentrations were explored, and regression models were developed relatingmore » changes in urinary MP concentrations to measured exposure levels. Full-shift measurements were made on 13 firefighters over 20 work shifts in winter 2004 at the US Forest Service Savannah River site, a National Environmental Research Park. The average workshift length across the 20 measured shifts was 701±95 min. LG and CO exposures were significantly correlated for samples where the filter measurement captured at least 60% of the work shift (16 samples), as well as for the smaller set of full-shift exposure samples (n¼9). PM2.5 and CO exposures were not significantly correlated, and LG and PM2.5 exposures were only significantly correlated for samples representing at least 60% of the work shift. Creatinine-corrected urinary concentrations for 20 of the 22 MPs showed cross-shift increases, with 14 of these changes showing statistical significance. Individual and summed creatinine-adjusted guaiacol urinary MPs were highly associated with CO (and, to a lesser degree, LG) exposure levels, and random-effects regression models including CO and LG exposure levels explained up to 80% of the variance in cross-shift changes in summed creatinine-adjusted guaiacol urinary MP concentrations. Although limited by the small sample size, this pilot study demonstrates that urinary MP concentrations may be effective biomarkers of occupational exposure to wood smoke among wildland firefighters.« less

  19. Biological monitoring of smoke exposure among wildland firefighters: Apilot study comparing urinary methoxyphenols with personal exposures to carbon monoxide, particulate matter, and levoglucosan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neitzel, R.; Naeher, L., P.; Paulsen, M.

    2009-04-01

    Urinary methoxyphenols (MPs) have been proposed as biomarkers of woodsmoke exposure. However, few field studies have been undertaken to evaluate the relationship between woodsmoke exposure and urinary MP concentrations. We conducted a pilot study at the US Forest ServiceFSavannah River Site, in which carbon monoxide (CO), levoglucosan (LG), and particulate matter (PM2.5) exposures were measured in wildland firefighters on prescribed burn days. Pre- and post-shift urine samples were collected from each subject, and cross-shift changes in creatinine-corrected urinary MP concentrations were calculated. Correlations between exposure measures and creatine-adjusted urinary MP concentrations were explored, and regression models were developed relating changesmore » in urinary MP concentrations to measured exposure levels. Full-shift measurements were made on 13 firefighters over 20 work shifts in winter 2004 at the US Forest Service Savannah River site, a National Environmental Research Park. The average workshift length across the 20 measured shifts was 701±95 min. LG and CO exposures were significantly correlated for samples where the filter measurement captured at least 60% of the work shift (16 samples), as well as for the smaller set of full-shift exposure samples (n¼9). PM2.5 and CO exposures were not significantly correlated, and LG and PM2.5 exposures were only significantly correlated for samples representing at least 60% of the work shift. Creatinine-corrected urinary concentrations for 20 of the 22 MPs showed cross-shift increases, with 14 of these changes showing statistical significance. Individual and summed creatinine-adjusted guaiacol urinary MPs were highly associated with CO (and, to a lesser degree, LG) exposure levels, and random-effects regression models including CO and LG exposure levels explained up to 80% of the variance in cross-shift changes in summed creatinine-adjusted guaiacol urinary MP concentrations. Although limited by the small sample size, this pilot study demonstrates that urinary MP concentrations may be effective biomarkers of occupational exposure to wood smoke among wildland firefighters.« less

  20. Biological monitoring of smoke exposure among wildland firefighters: Apilot study comparing urinary methoxyphenols with personal exposures to carbon monoxide, particulate matter, and levoglucosan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neitzel, R.; Naeher, L., P.; Paulsen, M.

    2008-04-01

    Urinary methoxyphenols (MPs) have been proposed as biomarkers of woodsmoke exposure. However, few field studies have been undertaken to evaluate the relationship between woodsmoke exposure and urinary MP concentrations. We conducted a pilot study at the US Forest Service Savannah River Site, in which carbon monoxide (CO), levoglucosan (LG), and particulate matter (PM2.5) exposures were measured in wildland firefighters on prescribed burn days. Pre- and post-shift urine samples were collected from each subject, and cross-shift changes in creatinine-corrected urinary MP concentrations were calculated. Correlations between exposure measures and creatine-adjusted urinary MP concentrations were explored, and regression models were developed relatingmore » changes in urinary MP concentrations to measured exposure levels. Full-shift measurements were made on 13 firefighters over 20 work shifts in winter 2004 at the US Forest Service Savannah River site, a National Environmental Research Park. The average workshift length across the 20 measured shifts was 701±95 min. LG and CO exposures were significantly correlated for samples where the filter measurement captured at least 60% of the work shift (16 samples), as well as for the smaller set of full-shift exposure samples (n¼9). PM2.5 and CO exposures were not significantly correlated, and LG and PM2.5 exposures were only significantly correlated for samples representing at least 60% of the work shift. Creatinine-corrected urinary concentrations for 20 of the 22 MPs showed cross-shift increases, with 14 of these changes showing statistical significance. Individual and summed creatinine-adjusted guaiacol urinary MPs were highly associated with CO (and, to a lesser degree, LG) exposure levels, and random-effects regression models including CO and LG exposure levels explained up to 80% of the variance in cross-shift changes in summed creatinine-adjusted guaiacol urinary MP concentrations. Although limited by the small sample size, this pilot study demonstrates that urinary MP concentrations may be effective biomarkers of occupational exposure to wood smoke among wildland firefighters.« less

  1. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  2. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-05-17

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated.

  3. Occupational heat strain in a hot underground metal mine.

    PubMed

    Lutz, Eric A; Reed, Rustin J; Turner, Dylan; Littau, Sally R

    2014-04-01

    In a hot underground metal mine, this study evaluated the relationship between job task, physical body type, work shift, and heat strain. Thirty-one miners were evaluated during 98 shifts while performing deep shaft-sinking tasks. Continuous core body temperature, heart rate, pre- and postshift urine specific gravity (USG), and body mass index were measured. Cutting and welding tasks were associated with significantly (P < 0.05) increased core body temperature, maximum heart rate, and increased postshift urine specific gravity. Miners in the obese level II and III body mass index categories, as well as those working night shift, had lower core body temperatures (P < 0.05). This study confirms that job task, body type, and shift are risk factors for heat strain.

  4. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides andmore » strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.« less

  5. Urine sodium excretion increased slightly among U.S. adults between 1988 and 2010.

    PubMed

    Pfeiffer, Christine M; Hughes, Jeffery P; Cogswell, Mary E; Burt, Vicki L; Lacher, David A; Lavoie, Donna J; Rabinowitz, Daniel J; Johnson, Clifford L; Pirkle, James L

    2014-05-01

    Little information is available on temporal trends in sodium intake in the U.S. population using urine sodium excretion as a biomarker. Our aim was to assess 1988-2010 trends in estimated 24-h urine sodium (24hUNa) excretion among U.S. adults (age 20-59 y) participating in the cross-sectional NHANES. We used subsamples from a 1988-1994 convenience sample, a 2003-2006 one-third random sample, and a 2010 one-third random sample to comply with resource constraints. We estimated 24hUNa excretion from measured sodium concentrations in spot urine samples by use of calibration equations (for men and women) derived from the International Cooperative Study on Salt, Other Factors, and Blood Pressure study. Estimated 24hUNa excretion increased over the 20-y period [1988-1994, 2003-2006, and 2010; means ± SEMs (n): 3160 ± 38.4 mg/d (1249), 3290 ± 29.4 mg/d (1235), and 3290 ± 44.4 mg/d (525), respectively; P-trend = 0.022]. We observed significantly higher mean estimated 24hUNa excretion in each survey period (P < 0.001) for men compared with women (31-33%) and for persons with a higher body mass index (BMI; 32-35% for obese vs. normal weight) or blood pressure (17-26% for hypertensive vs. normal blood pressure). After adjusting for age, sex, and race-ethnicity, temporal trends in mean estimated 24hUNa excretion remained significant (P-trend = 0.004). We observed no temporal trends in mean estimated 24hUNa excretion among BMI subgroups, nor after adjusting for BMI. Although several limitations apply to this analysis (the use of a convenience sample in 1988-1994 and using estimated 24hUNa excretion as a biomarker of sodium intake), these first NHANES data suggest that mean estimated 24hUNa excretion increased slightly in U.S. adults over the past 2 decades, and this increase may be explained by a shift in the distribution of BMI.

  6. Dermal uptake and excretion of 4,4'-methylenedianiline during rotor blade production in helicopter industry--an intervention study.

    PubMed

    Weiss, Tobias; Schuster, Hubert; Müller, Johannes; Schaller, Karl-Heinz; Drexler, Hans; Angerer, Jürgen; Käfferlein, Heiko U

    2011-10-01

    Workers using composite materials by fibre reinforced laminate technology are exposed to 4,4'-methylenedianiline (MDA), a liver toxicant and suspected human carcinogen, during the production of rotor blades in helicopter industry. The aim of the study presented here was to assess the internal dose of MDA and the suitability of various personal protection measures at the workplace. Ambient monitoring and biological monitoring was carried out by analysing MDA in air and urine samples in seven workers of a highly specialized workplace (rotor blade production). Three different concepts of personal protection measures were applied to study the route of uptake and to evaluate strategies in decreasing workplace exposure. In addition, elimination kinetics of MDA was studied in three workers who were exposed to MDA on three consecutive working days. Ambient monitoring consistently provided air levels at or below the limit of quantification of 0.1 μg m(-3). Nevertheless, MDA was detected in 89% of all post-shift urine samples and median concentration was 4.2 μg l(-1). MDA in urine were >20 times higher than expected on data from ambient monitoring alone. A significant decrease in exposure could be achieved when workers have worn MDA-protective overalls in combination with MDA-protective gloves and a splash protection shield (from 9.8 μg l(-1) down to 3.7 μg l(-1)). The results show that MDA is taken up primarily via the skin at the workplaces under study. The excretion of MDA in urine was observed to be delayed after dermal exposure. Exposure assessment of MDA should be carried out by biological monitoring rather than ambient monitoring. For this purpose, urine samples midweek or at the end of the week should be used based on the observed delay in the excretion of MDA after dermal absorption. Uptake of MDA via the skin could not be completely avoided even if state-of-the-art personal protection measures were applied.

  7. [Effect of the night shift work on micturition patterns of nurses].

    PubMed

    Wang, Q; Hu, H; Liang, C; Wang, J; Xu, K X

    2016-02-18

    To compare the effects of rotational night shifts on the micturition patterns of female nurses. A total of 58 nurses without lower urinary tract symptoms were recruited, who worked in the Peking University People's Hospital during January and June in 2014. The nurses aged 20-43 years were divided into two groups, the night-shift group (n=28) and the non-shift group (n=30). The alcohol or coffee intaking were forbidden. In the night-shift group, nurses had worked on rotational shifts for at least 6 months. Their average age was (26.75±4.11) years. In the non-shift group, nurses took regular day-time work, whose average age was (27.80±5.60) years. A voiding diary was kept for 7 consecutive days at the end of 6 months, starting 2 days before their night duties until 4 days after completion of their night duties. For comparison, the non-shift group with regular shifts completed a 7-day voiding diary. In the 7-day recording voiding diary, the nurses were required to have the normal intake of liquid about 1 500-2 000 mL/d. The frequency volume charts of nocturia, the 8-hour interval urine production and frequency were compared between the two groups. Nocturia frequency was increased in the night-shift group [0.5 (0-2.4)] compared with the non-shift group [0 (0-2), P=0.02]. The volume of nocturia was increased in the night-shift group [125 mL (0-660 mL)] compared with the non-shift group [0 mL (0-340 mL), P<0.01]. The 8-hour interval indices showed that urine production changed with shift (P<0.01). In the consecutive 7 days, the nocturnal volume of the night-shift group increased on the day after night shift. When the night-shift nurses returned to daytime duty, the volume of urine decreased but nocturnal urine production remained high, and the frequency of nocturia also increased significantly (P<0.05). Compared with the 8-hour interval indices, the night-shift group's voiding volume [(542.35±204.66) mL] and voiding frequency (2.24±0.69) were more than those of the non-shift group at the afternoon time (from 2 pm to 10 pm). During the 8 h interval night time (from 10 pm to 6 am), the volume of nocturia in the night-shift group [(309.74±162.74) mL] was more than that in the non-shift group [(199.38±153.98) mL, P=0.01]; the frequency of nocturia in the night-shift group (1.31±0.52) was increased than that in the non-shift group (0.82±0.55, P<0.01). The rotational shifts affect the micturition patterns of nurses who go through the night shift work, which increases the volume and frequency of the nocturia.

  8. [Effect of the night shift work on micturition patterns of nurses].

    PubMed

    Wang, Q; Hu, H; Liang, C; Wang, J; Xu, K X

    2016-08-18

    To compare the effects of rotational night shifts on the micturition patterns of female nurses. A total of 58 nurses without lower urinary tract symptoms were recruited, who worked in the Peking University People's Hospital during January and June in 2014. The nurses aged 20-43 years were divided into two groups, the night-shift group (n=28) and the non-shift group (n=30). The alcohol or coffee intaking were forbidden. In the night-shift group, nurses had worked on rotational shifts for at least 6 months. Their average age was (26.75±4.11) years. In the non-shift group, nurses took regular day-time work, whose average age was (27.80±5.60) years. A voiding diary was kept for 7 consecutive days at the end of 6 months, starting 2 days before their night duties until 4 days after completion of their night duties. For comparison, the non-shift group with regular shifts completed a 7-day voiding diary. In the 7-day recording voiding diary, the nurses were required to have the normal intake of liquid about 1 500-2 000 mL/d. The frequency volume charts of nocturia, the 8-hour interval urine production and frequency were compared between the two groups. Nocturia frequency was increased in the night-shift group [0.5 (0-2.4)] compared with the non-shift group [0 (0-2), P=0.02]. The volume of nocturia was increased in the night-shift group [125 mL (0-660 mL)] compared with the non-shift group [0 mL (0-340 mL), P<0.01]. The 8-hour interval indices showed that urine production changed with shift (P<0.01). In the consecutive 7 days, the nocturnal volume of the night-shift group increased on the day after night shift. When the night-shift nurses returned to daytime duty, the volume of urine decreased but nocturnal urine production remained high, and the frequency of nocturia also increased significantly (P<0.05). Compared with the 8-hour interval indices, the night-shift group's voiding volume [(542.35±204.66) mL] and voiding frequency (2.24±0.69) were more than those of the non-shift group at the afternoon time (from 2 pm to 10 pm). During the 8 h interval night time (from 10 pm to 6 am), the volume of nocturia in the night-shift group [(309.74±162.74) mL] was more than that in the non-shift group [(199.38±153.98) mL, P=0.01]; the frequency of nocturia in the night-shift group (1.31±0.52) was increased than that in the non-shift group (0.82±0.55, P<0.01). The rotational shifts affect the micturition patterns of nurses who go through the night shift work, which increases the volume and frequency of the nocturia.

  9. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    PubMed Central

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117

  10. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    PubMed

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.

  11. Astronaut health monitoring

    NASA Astrophysics Data System (ADS)

    Inscore, Frank; Shende, Chetan; Gift, Alan; Maksymiuk, Paul; Farquharson, Stuart

    2006-10-01

    Extended weightlessness causes numerous deleterious changes in human physiology, including space motion sickness, cephalad fluid shifts, reduced immune response, and breakdown of muscle tissue with subsequent loss of bone mass and formation of renal stones. Furthermore, these physiological changes also influence the metabolism of drugs used by astronauts to minimize these deleterious effects. Unfortunately, the changes in human physiology in space are also reflected in drug metabolism, and current pre-flight analyses designed to set dosage are inadequate. Furthermore, current earth-based analytical laboratory methods that employ liquid or gas chromatography for separation and fluorescence or mass spectrometry for trace detection are labor intensive, slow, massive, and not cost-effective for operation in space. In an effort to overcome these instrument limitations we have been developing a sampling device to both separate these drugs and metabolites from urine, and generate surface-enhanced Raman (SER) spectra. The detailed molecular vibrational information afforded by Raman scattering allows chemical identification, while the surface-enhancement increases sensitivity by six or more orders of magnitude and allows detection of nanogram per milliliter concentrations. Generally no more than 1 milliliter of sample is required and complete analysis can be performed in 5 minutes using a portable, light-weight Raman spectrometer. Here we present the SER analysis of several drugs used by astronauts measured in synthetic urine and reconstituted urine.

  12. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  13. Whole Genome Expression in Peripheral-Blood Samples of Workers Professionally Exposed to Polycyclic Aromatic Hydrocarbons

    PubMed Central

    Wu, Ming-Tsang; Lee, Tzu-Chi; Su, Hung-Ju; Huang, Jie-Len; Peng, Chiung-Yu; Wang, Weihsin; Chou, Ting-Yu; Lin, Ming-Yen; Lin, Wen-Yi; Huang, Chia-Tsuan; Pan, Chih-Hong; Ho, Chi-Kung

    2011-01-01

    This study aims to examine global gene expression profiles before and after the work-shift among coke-oven workers (COW). COW work six consecutive days and then take two days off. Two blood and urine samples in each worker were collected before starting to work after two-days off and end-of-shift in the sixth-day work in 2009. Altered gene expressions (ratio of gene expression levels between end-of-shift and pre-shift work) were performed by Human OneArray expression system which probes ∼30,000-transcription expression profiling of human genes. Sixteen workers, all men, were enrolled in this study. Median urinary 1-hydroxypyrene (1OHP) levels (μmole/mole creatinine) in end-of-shift work were significantly higher than those in pre-shift work (2.58 vs. 0.29, p = 0.0002). Among the 20,341 genes which passed experimental quality control, 26 gene expression changes, 7 positive and 19 negative, were highly correlated with across-the-shift urinary 1OHP levels (end-of-shift – pre-shift 1OHP) (p-value < 0.001). The high and low exposure groups of across-the-shift urinary 1OHP levels dichotomized in ∼2.00 μmole/mole creatinine were able to be distinguished by these 26 genes. Some of them are known to be involved in apoptosis, chromosome stability/DNA repair, cell cycle control/tumor suppressor, cell adhesion, development/spermatogenesis, immune function, and neuronal cell function. These findings in COW will be an ideal model to study the relationship of PAHs exposure with acute changes of gene expressions. PMID:21854004

  14. Porphyrins - urine test

    MedlinePlus

    Urine uroporphyrin; Urine coproporphyrin; Porphyria - uroporphyrin ... After you provide a urine sample, it is tested in the lab. This is called a random urine sample. If needed, your health care provider ...

  15. Oxidative DNA damage during night shift work.

    PubMed

    Bhatti, Parveen; Mirick, Dana K; Randolph, Timothy W; Gong, Jicheng; Buchanan, Diana Taibi; Zhang, Junfeng Jim; Davis, Scott

    2017-09-01

    We previously reported that compared with night sleep, day sleep among shift workers was associated with reduced urinary excretion of 8-hydroxydeoxyguanosine (8-OH-dG), potentially reflecting a reduced ability to repair 8-OH-dG lesions in DNA. We identified the absence of melatonin during day sleep as the likely causative factor. We now investigate whether night work is also associated with reduced urinary excretion of 8-OH-dG. For this cross-sectional study, 50 shift workers with the largest negative differences in night work versus night sleep circulating melatonin levels (measured as 6-sulfatoxymelatonin in urine) were selected from among the 223 shift workers included in our previous study. 8-OH-dG concentrations were measured in stored urine samples using high performance liquid chromatography with electrochemical detection. Mixed effects models were used to compare night work versus night sleep 8-OH-dG levels. Circulating melatonin levels during night work (mean=17.1 ng/mg creatinine/mg creatinine) were much lower than during night sleep (mean=51.7 ng/mg creatinine). In adjusted analyses, average urinary 8-OH-dG levels during the night work period were only 20% of those observed during the night sleep period (95% CI 10% to 30%; p<0.001). This study suggests that night work, relative to night sleep, is associated with reduced repair of 8-OH-dG lesions in DNA and that the effect is likely driven by melatonin suppression occurring during night work relative to night sleep. If confirmed, future studies should evaluate melatonin supplementation as a means to restore oxidative DNA damage repair capacity among shift workers. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. The method of urine sampling is not a valid predictor for vesicoureteral reflux in children after febrile urinary tract infections.

    PubMed

    Haid, Bernhard; Roesch, Judith; Strasser, Christa; Oswald, Josef

    2017-10-01

    The likelihood of detecting vesicoureteral reflux (VUR) after febrile urinary tract infections (UTI) in children logically should correlate with the correct diagnosis of the UTI. Beneath the unspecific symptoms of fever urine analysis is the main diagnostic criterion for the exact diagnosis of febrile UTIs in children. Use of inadequate urine sampling techniques during diagnosis may lead to impaired accuracy in UTI diagnosis. This could lead to the assumption that children, having diagnosed their UTI by the use of possibly inadequate urine sampling techniques should not be evaluated as consequently compared to those, where the diagnosis relied on sterile urine sampling techniques. We hypothesized that children with possibly contaminated urine samples during the initial diagnosis may show a lower rate of VUR in subsequent VCUGs because of a wrong diagnosis initially compared to children, where accurate urine sampling techniques were used. Between 2009 and 2014, a total of 555 patients underwent a primary VCUG at our department indicated because of febrile UTIs. Patients with urine collection methods other than bag urine and catheter/suprapubic aspiration (SPA) were excluded from this study (mid-stream urine, potty urine, n = 149). We evaluated 402 patients (male/female 131/271, mean age 1.91 years), VUR rates and grades were compared between patients where urine was sampled by the use of a urine bag only at the time of diagnosis (n = 296, 73.6%) and those where sterile urine sampling (catheter, suprapubic puncture) was performed (n = 106, 26.3%). 4 patients were excluded due to equivocal data on urine sampling. VUR rate in children after sterile urine sampling using a catheter or SPA accounted to 31.1%. In those where urine samples acquired by the use of urine bags were used, 33.7% showed VUR on subsequent VCUG (p = 0.718). There were no significant differences as to VUR grades or gender, although VUR was much more commonly diagnosed in female patients (37.0% vs 28.2%, p = 0.227) (Figure). Children diagnosed with their UTI by use of bag urine in our experience carried the same risk of showing a VUR in a subsequent VCUG compared to those, where the initial diagnosis relied - beneath clinical criteria - on urine samples acquired by suprapubic puncture or catheterization. Consequently urine-sampling technique during initial UTI diagnosis alone should not be used as predictor for the reliability of UTI diagnosis and should not influence the further management after UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  17. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  18. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  19. Urine sample (image)

    MedlinePlus

    A "clean-catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head ... water and rinse well. A small amount of urine should initially fall into the toilet bowl before ...

  20. Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.

    PubMed

    Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S

    2013-01-01

    To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.

  1. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    PubMed

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  2. Urine output on an intensive care unit: case-control study.

    PubMed

    Solomon, Anthony W; Kirwan, Christopher J; Alexander, Neal D E; Nimako, Kofi; Jurukov, Angela; Forth, Rebecca J; Rahman, Tony M

    2010-12-14

    To compare urine output between junior doctors in an intensive care unit and the patients for whom they are responsible. Case-control study. General intensive care unit in a tertiary referral hospital. 18 junior doctors responsible for clerking patients on weekday day shifts in the unit from 23 March to 23 April 2009 volunteered as "cases." Controls were the patients in the unit clerked by those doctors. Exclusion criteria (for both groups) were pregnancy, baseline estimated glomerular filtration rate <15 ml/min/1.73 m(2), and renal replacement therapy. Oliguria (defined as mean urine output <0.5 ml/kg/hour over six or more hours of measurement) and urine output (in ml/kg/hour) as a continuous variable. Doctors were classed as oliguric and "at risk" of acute kidney injury on 19 (22%) of 87 shifts in which urine output was measured, and oliguric to the point of being "in injury" on one (1%) further shift. Data were available for 208 of 209 controls matched to cases in the data collection period; 13 of these were excluded because the control was receiving renal replacement therapy. Doctors were more likely to be oliguric than their patients (odds ratio 1.99, 95% confidence interval 1.08 to 3.68, P=0.03). For each additional 1 ml/kg/hour mean urine output, the odds ratio for being a case rather than a control was 0.27 (0.12 to 0.58, P=0.001). Mortality among doctors was astonishingly low, at 0% (0% to 18%). Managing our own fluid balance is more difficult than managing it in our patients. We should drink more water. Modifications to the criteria for acute kidney injury could be needed for the assessment of junior doctors in an intensive care unit.

  3. Misclassification of iodine intake level from morning spot urine samples with high iodine excretion among Inuit and non-Inuit in Greenland.

    PubMed

    Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter

    2015-05-14

    Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.

  4. Stability of cannabinoids in urine in three storage temperatures.

    PubMed

    Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C

    1998-01-01

    Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.

  5. Substitution of human for horse urine disproves an accusation of doping*.

    PubMed

    Díaz, Silvina; Kienast, Mariana E; Villegas-Castagnasso, Egle E; Pena, Natalia L; Manganare, Marcos M; Posik, Diego; Peral-García, Pilar; Giovambattista, Guillermo

    2008-09-01

    In order to detect switching and/or manipulation of samples, the owner of a stallion asked our lab to perform a DNA test on a positive doping urine sample. The objective was to compare the urine DNA profile versus blood and hair DNA profiles from the same stallion. At first, 10 microsatellite markers were investigated to determine the horse identity. No results were obtained when horse specific markers were typed in the urine sample. In order to confirm the species origin of this sample we analyzed the mitochondrial cytochrome b gene. This analysis from blood and hair samples produced reproducible and clear PCR-RFLP patterns and DNA sequence match with those expected for horse, while the urine sample results were coincident with human. These results allowed us to exclude the urine sample from the questioned stallion and determine its human species origin, confirming the manipulation of urine sample.

  6. Urine melanin test

    MedlinePlus

    Thormahlen's test; Melanin - urine ... A clean-catch urine sample is needed. ... this substance that it shows up in the urine. ... Normally, melanin is not present in urine. Normal value ranges may ... measurements or test different samples. Talk to your health ...

  7. Effects of night shift on the cognitive load of physicians and urinary steroid hormone profiles - a randomized crossover trial.

    PubMed

    Osterode, Wolf; Schranz, Sandra; Jordakieva, Galateja

    2018-03-21

    Mental and physical stress is common in physicians during night shifts. Neurocognitive effects of sleep deprivation as well as alterations in hormonal and metabolic parameters have previously been described. The aim of this crossover study was to evaluate the effects of night-shift work with partial sleep deprivation on steroid hormone excretion and possible associations with mood, sleep characteristics and cognitive functions in physicians. In total, 34 physicians (mean age 42 ± 8.5 years, 76.5% male) from different departments of the General Hospital of Vienna, Austria, were randomly assigned to two conditions: a regular day shift (8 h on duty, condition 1) and a continuous day-night shift (24 h on duty, condition 2). In both conditions, physicians collected a 24 h urine sample for steroid hormone concentration analysis and further completed psychological tests, including the sleep questionnaire (SF-A), the questionnaire for mental state (MDBF) and the computer-assisted visual memory test (FVW) before and at the end of their shifts, respectively. Although mean sleep deprivation during night shift was relatively small (~1.5 h) the impairment in participants' mental state was high in all three dimensions (mood, vigilance and agitation, p ≤ 0.001). Sleep quality (SQ), feeling of being recovered after sleep and mental balance decreased (p ≤ 0.001), whereas mental exhaustion increased (p < 0.05). Moreover, we could show a nearly linear relationship between most of these self-rating items. Testing visual memory participants made significantly more mistakes after night shift (p = 0.011), however, mostly in incorrectly identified items and not in correctly identified ones (FVW). SQ and false identified items were negatively correlated, whereas SQ and time of reaction were positively associated. It is assumed that after night shift, a tendency exists to make faster wrong decisions. SQ did not influence correctly identified items in FVW. In contrast to previous investigations, we found that only excretion rates for pregnanetriol and androsterone/etiocholanolone ratios (p < 0.05, respectively) were slightly reduced in 24-h urine samples after night shift. A considerable stimulation of the adrenocortical axis could not be affirmed. In general, dehydroepiandrosteron (DHEA) was negatively associated with the sense of recreation after sleep and with the time of reaction and positively correlated with correctly identified items in the FVW test. These results, on the one hand, are in line with previous findings indicating that stress and sleep deprivation suppress gonadal steroids, but, on the other hand, do not imply significant adrenocortical-axis stimulation (e.g. an increase of cortisol) during the day-night shift.

  8. Diagnostic value of JC/BK virus antibody immunohistochemistry staining in urine samples from posttransplant immunosuppressed patients in relation to polyomavirus reactivation.

    PubMed

    Yuste, Rosario Sanchez; Frías, Carolina; López, Ana; Vallejo, Carlos; Martín, Paloma; Bellas, Carmen

    2008-01-01

    To compare the diagnostic value of cytology and immunohistochemistry staining (IHS) of urine samples for polyomavirus reactivation diagnosis. Sixty-eight urine samples collected from 18 immunosuppressed patients were analyzed by Papanicolaou and IHS with a JC/BK virus-specific monoclonal antibody. Overall, polyomavirus BK (BKV) was positive in 11 of 18 patients (61.1%) (3 of whom developed hemorrhagic cystitis) and in 23 of 68 urine samples (28%). Of 23 samples, 4 (17%) were positive by 1 of the 2 techniques, only. Of 23 samples, 19 (83%) were positive by both methods. In matching urine samples from the same patient, the number of BKV-infected positive cells detected by IHS in urine slides was higher than those detected by Papanicolaou staining (71.3%). The main advantage of LHS is that it allowed confirmation of BKV infection diagnosis in urine samples. IHS detected more BKV-infected cells in samples with few positive urothelial cells, which would have gone undetected if only Papanicolaou staining had been used as the BKV screening method. Urine samples testing for BKV by both techniques will improve diagnosis in asymptomatic patients, allowing early therapeutic intervention and a better clinical outcome.

  9. Basic or extended urine sampling to analyse urine production?

    PubMed

    Denys, Marie-Astrid; Kapila, Vansh; Weiss, Jeffrey; Goessaert, An-Sofie; Everaert, Karel

    2017-09-01

    Frequency volume charts are valuable tools to objectify urine production in patients with nocturia, enuresis or nocturnal incontinence. Analyses of daytime and nighttime urine (=basic collection) or analyses of urine samples collected every 3 h (=extended collection) extend this evaluation by describing circadian patterns of water and solute diuresis (=renal function profiles). To assess intra-individual correlation and agreement between renal function profiles provided using basic and extended urine collections, and using two extended urine collections. To create a short-form of the extended collection. This prospective observational study was executed at Ghent University Hospital, Belgium. Study participation was open for anyone visiting the hospital. Participants collected one basic and two extended 24-h urine collections. Urinary levels of osmolality, sodium and creatinine were determined. There was a moderate to strong correlation between results of basic and extended urinalyses. Comparing both extended urinalyses showed a moderate correlation between the eight individual samples and a weak to strong correlation between the mean daytime and nighttime values of renal functions. Different samples could be considered as most representative for mean daytime values, while all samples collected between 03 and 05am showed the highest agreement with mean nighttime values of renal function. Since there is a good correlation and agreement between basic and extended urine collections to study the mechanisms underlying urine production, the choice of urine sampling method to evaluate urine production depends on the purpose. A nighttime-only urine sample collected between 03 and 05am may be the most practical approach. © 2017 Wiley Periodicals, Inc.

  10. Effects of diet composition on mutagenic activity in urine.

    PubMed

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  11. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  12. Exposure to organophosphate flame retardants of hotel room attendants in Wuhan City, China.

    PubMed

    Tao, Yun; Shang, Yinzhu; Li, Jing; Feng, Jingwen; He, Zhenyu; Covaci, Adrian; Wang, Peng; Luo, Jing; Mao, Xiang; Shi, Bin; Hu, Liqin; Luo, Dan; Mei, Surong

    2018-05-01

    Indoor environments provide sources of exposure to organophosphate flame retardants (PFRs), which are artificially synthesized fire-protecting agents used as additives in interior products. As public spaces, hotels are required to meet stricter fire-precaution criteria. As such, room attendants may be exposed to higher levels of PFRs. Our goal was to characterize the exposure of hotel room attendants to PFRs by measuring metabolites in their urine and the corresponding parent PFRs in dust and hand-wipes collected from 27 hotels located in Wuhan City, China. The exposure of the attendants was found to be omnipresent: urinary metabolites of PFRs, such as DPHP (diphenyl phosphate), BDCIPP (bis(1,3-dichloro-2-propyl) phosphate), and DoCP (di-o-cresyl phosphate) & DpCP (di-p-cresyl phosphate) were detected with high frequency (87%, 79% and 87%, respectively). We observed that metabolites in post-shift urine were consistently present at higher levels than those in the first morning voids (p < 0.05 for BDCIPP and DPHP). Regarding external exposure, 10 PFRs were determined in both dust samples and hand-wipes, with TCIPP (tris(2-chloroisopropyl) phosphate) being the most abundant compound in both matrices. The levels of PFRs in hand-wipes and dust samples were not correlated. PFRs in dust and their corresponding urinary metabolites were not significantly correlated, while a moderate significant correlation of TDCIPP (tris(1,3-dichloro-2-propyl) phosphate) in hand-wipes and its urinary metabolite, BDCIPP, was observed in both morning void samples (p = 0.01) and post-shift urine (p = 0.002). Moreover, we found that participants from high-rise buildings (defined as > 7 stories) had significantly higher BDCIPP and DPHP concentrations than those from low-rise buildings. A possible reason is that high-rise buildings may use high-grade fireproof building materials to meet stricter fire restrictions. Overall, these results indicate that PFRs exposure in hotels is a contributor to the personal exposure of hotel room attendants. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Antibiotic Screening of Urine Culture for Internal Quality Audit at Amrita Hospital, Kochi.

    PubMed

    Suresh, Aswathy; Gopinathan, Anusha; Dinesh, Kavitha R; Kumar, Anil

    2017-07-01

    Urine antimicrobial activity is a seldom analysed laboratory test which greatly impacts the quantification of urine specimens. Presence of antimicrobial activity in the urine reduces the bacterial load in these specimens. Hence, the chances of erroneously reporting insignificant bacteriuria can be reduced on analysis of the antimicrobial activity in urine. The aim of the study was to measure the antimicrobial activity of urine samples obtained from patients in a tertiary care hospital. A total of 100 urine specimens were collected from the study group. Tests like wet mount, Gram staining and culture were performed. Antimicrobial susceptibility testing was done on the bacteria isolated from each specimen. The urine specimens were reported as significant bacteriuria (>105 Colony Forming Unit (CFU)/ml) and insignificant bacteriuria (<105 CFU/ml - clean catch midstream urine; <102 CFU/ml - catheterized urine sample) according to the CFU/ml. Staphylococcus aureus ATCC ® 25923 ™ and Escherichia coli ATCC ® 25922 ™ were used to identify the presence of antimicrobial activity in the urine sample by Urine Anti-Bacterial substance Assay (UABA). McNemar test was used for statistical analysis using Statistical Package for the Social Sciences (SPSS) version 21.0. On analysis of the antimicrobial activity of urine sample with the prior antibiotic history of the patients, 17 were true positives and 43 were true negatives. Twenty six of samples with UABA positivity were culture negative and 28 samples with UABA positivity were culture positive. Sensitivity and specificity of the test was 85% and 53.8% respectively. Accuracy of the test was 60%. The p-value of UABA was <0.001. Enterobacteriaceae was the most common bacterial family isolated from the urine specimens. A total of 85% patients responded to treatment. Presence of antimicrobial activity in urine has a great impact on the interpretation of urine culture reports. Identification of urine antimicrobial activity helps in evaluating the quantification of bacterial growth reported in urine culture. It facilitates speedy recovery of patients by early administration of antibiotics.

  14. Mean population salt intake estimated from 24-h urine samples and spot urine samples: a systematic review and meta-analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason H Y; Woodward, Mark; Barzi, Federica; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Neal, Bruce

    2016-02-01

    Estimating equations based on spot urine samples have been identified as a possible alternative approach to 24-h urine collections for determining mean population salt intake. This review compares estimates of mean population salt intake based upon spot and 24-h urine samples. We systematically searched for all studies that reported estimates of daily salt intake based upon both spot and 24-h urine samples for the same population. The associations between the two were quantified and compared overall and in subsets of studies. A total of 538 records were identified, 108 were assessed as full text and 29 were included. The included studies involved 10,414 participants from 34 countries and made 71 comparisons available for the primary analysis. Overall average population salt intake estimated from 24-h urine samples was 9.3 g/day compared with 9.0 g/day estimated from the spot urine samples. Estimates based upon spot urine samples had excellent sensitivity (97%) and specificity (100%) at classifying mean population salt intake as above or below the World Health Organization maximum target of 5 g/day. Compared with the 24-h samples, estimates based upon spot urine overestimated intake at lower levels of consumption and underestimated intake at higher levels of consumption. Estimates of mean population salt intake based upon spot urine samples can provide countries with a good indication of mean population salt intake and whether action on salt consumption is required. Published by Oxford University Press on behalf of the International Epidemiological Association 2015. This work is written by US Government employees and is in the public domain in the US.

  15. Associations between heat exposure, vigilance, and balance performance in summer tree fruit harvesters.

    PubMed

    Spector, June T; Krenz, Jennifer; Calkins, Miriam; Ryan, Dawn; Carmona, Jose; Pan, Mengjie; Zemke, Anna; Sampson, Paul D

    2018-02-01

    We sought to evaluate potential mediators of the relationship between heat exposure and traumatic injuries in outdoor agricultural workers. Linear mixed models were used to estimate associations between maximum work-shift Wet Bulb Globe Temperature (WBGT max ) and post-shift vigilance (reaction time) and postural sway (total path length) in a cross-sectional sample of 46 Washington State tree fruit harvesters in August-September 2015. The mean (SD) WBGT max was 27.4 (3.2)°C in August and 21.2 (2.0)°C in September. The mean pre-work-shift participant urine specific gravity indicated minimal dehydration. Twenty-four percent of participants exhibited possible excessive sleepiness. There was no association between WBGT max and post-shift reaction time or total path length. Heat exposure was not associated with impaired vigilance or balance in this study, in which the overall mean (SD) WBGT max was 25.9 (4.2)°C. However, the study identified opportunities to ensure adequate pre-work-shift hydration and to optimize sleep and work-shift timing in order to reduce occupational injury and heat-related illness risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Estimating mean change in population salt intake using spot urine samples.

    PubMed

    Petersen, Kristina S; Wu, Jason H Y; Webster, Jacqui; Grimes, Carley; Woodward, Mark; Nowson, Caryl A; Neal, Bruce

    2017-10-01

    Spot urine samples are easier to collect than 24-h urine samples and have been used with estimating equations to derive the mean daily salt intake of a population. Whether equations using data from spot urine samples can also be used to estimate change in mean daily population salt intake over time is unknown. We compared estimates of change in mean daily population salt intake based upon 24-h urine collections with estimates derived using equations based on spot urine samples. Paired and unpaired 24-h urine samples and spot urine samples were collected from individuals in two Australian populations, in 2011 and 2014. Estimates of change in daily mean population salt intake between 2011 and 2014 were obtained directly from the 24-h urine samples and by applying established estimating equations (Kawasaki, Tanaka, Mage, Toft, INTERSALT) to the data from spot urine samples. Differences between 2011 and 2014 were calculated using mixed models. A total of 1000 participants provided a 24-h urine sample and a spot urine sample in 2011, and 1012 did so in 2014 (paired samples n = 870; unpaired samples n = 1142). The participants were community-dwelling individuals living in the State of Victoria or the town of Lithgow in the State of New South Wales, Australia, with a mean age of 55 years in 2011. The mean (95% confidence interval) difference in population salt intake between 2011 and 2014 determined from the 24-h urine samples was -0.48g/day (-0.74 to -0.21; P < 0.001). The corresponding result estimated from the spot urine samples was -0.24 g/day (-0.42 to -0.06; P = 0.01) using the Tanaka equation, -0.42 g/day (-0.70 to -0.13; p = 0.004) using the Kawasaki equation, -0.51 g/day (-1.00 to -0.01; P = 0.046) using the Mage equation, -0.26 g/day (-0.42 to -0.10; P = 0.001) using the Toft equation, -0.20 g/day (-0.32 to -0.09; P = 0.001) using the INTERSALT equation and -0.27 g/day (-0.39 to -0.15; P < 0.001) using the INTERSALT equation with potassium. There was no evidence that the changes detected by the 24-h collections and estimating equations were different (all P > 0.058). Separate analysis of the unpaired and paired data showed that detection of change by the estimating equations was observed only in the paired data. All the estimating equations based upon spot urine samples identified a similar change in daily salt intake to that detected by the 24-h urine samples. Methods based upon spot urine samples may provide an approach to measuring change in mean population salt intake, although further investigation in larger and more diverse population groups is required. © The Author 2016; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association

  17. Monitoring of occupational exposure to methylene chloride: sampling protocol and stability of urine samples.

    PubMed

    Hoffer, Erica; Tabak, Arek; Shcherb, Inna; Wiener, Avi; Bentur, Yedidia

    2005-01-01

    A sampling protocol for biomonitoring of the volatile solvent methylene chloride (MeCl(2)) by analysis of urine from exposed workers was established. Storage temperature, sample volume in headspace vial (HSV), and time to sealing HSV on determination of MeCl(2) in urine were evaluated. MeCl(2) was analyzed by a solid-phase microextraction technique combined with gas chromatography. Volume of urine in HSV has no effect on MeCl(2) analysis. Delays of 30 and 60 min from collection of urine until sealing the HSV caused 14.47 +/- 6.98% and 26.17 +/- 9.57% decreases from baseline concentration, respectively. MeCl(2) concentration in spiked urine samples stored in sealed HSVs decreased on day 2 and then remained stable for 2 weeks. Refrigeration did not improve recovery although it seems to be associated with less variability. MeCl(2) in urine samples of seven exposed workers was in the range of 0.02-0.06 mg/L. Sampling of MeCl(2)-containing urine should include collection of urine in closed plastic bottles, transfer to HSV within 15 min, sealing and clamping of HSV within 15 s, and storage of HSV in refrigeration until analysis, but no longer than 2 weeks. Standard samples should be prepared on the day of test sample collection and handled under the same conditions.

  18. Evaluation of the performance of Human Papillomavirus testing in paired urine and clinician-collected cervical samples among women aged over 30 years in Bhutan.

    PubMed

    Tshomo, Ugyen; Franceschi, Silvia; Tshokey, Tshokey; Tobgay, Tashi; Baussano, Iacopo; Tenet, Vanessa; Snijders, Peter J F; Gheit, Tarik; Tommasino, Massimo; Vorsters, Alex; Clifford, Gary M

    2017-04-08

    Urine sampling may offer a less invasive solution than cervical sampling to test for human papillomavirus (HPV) for HPV vaccine impact monitoring. Paired samples of urine and exfoliated cervical cells were obtained for 89 women with history of high-risk (HR) HPV-positive normal cytology in Bhutan. Urine sampling protocol included self-collection of first-void urine immediately into a conservation medium and procedures to optimize DNA yield. Colposcopical abnormalities were biopsied. Two HPV assays were used: a multiplex type-specific PCR (E7-MPG) and a less analytically sensitive GP5+/6+ PCR followed by reverse line blot. HPV positivity for 21 types common to both assays was similar in urine and cells by E7-MPG (62.9% and 57.3%, respectively, p = 0.32) but lower in urine by GP5+/6+ (30.3% and 40.4%, p = 0.05). HPV6/11/16/18 positivity did not significantly differ between urine and cells by either assay. Sensitivity of urine (using cells as gold standard) to detect 21 HPV types was 80% and 58% for E7-MPG and GP5+/6+, respectively, with specificity 61% and 89%. HPV type distribution in urine and cells was similar, regardless of assay. The 5 detected CIN3+ were HR-HPV positive in cells by both assays, compared to 4 and 3 by E7-MPG and GP5+/6+, respectively, in urine samples. For the monitoring of vaccine impact, we demonstrate validity of a urine sampling protocol to obtain HPV prevalence data that are broadly comparable to that from cervical cells. However, detection of HPV in urine varies according to assay sensitivity, presumably because low level infections are frequent.

  19. Comparison of Human Papillomavirus Detections in Urine, Vulvar, and Cervical Samples from Women Attending a Colposcopy Clinic

    PubMed Central

    Gravitt, Patti E.; Dunn, S. Terence; Brown, David; Allen, Richard A.; Eby, Yolanda J.; Smith, Katie; Zuna, Rosemary E.; Zhang, Roy R.; Gold, Michael A.; Schiffman, Mark; Walker, Joan L.; Castle, Philip E.; Wentzensen, Nicolas

    2014-01-01

    While urine-based sampling for human papillomavirus (HPV) is being explored as a simple and noninvasive approach for cervical cancer screening, data comparing HPV genotyping in urine and those in cellular sampling of the cervix and vulva, and their correlation with rigorously confirmed cervical disease status, are sparse. We performed HPV genotyping on voided-urine and clinician-collected vulvar and cervical samples from 72 women undergoing colposcopy. Although urine-based HPV carcinogenic HPV detection was lower (58.3%) than cervical (73.6%) and vulvar (72.1%) detection (P = 0.05 and 0.07, respectively), the agreement of urine HPV with cervical and vulvar HPV was moderate (kappa = 0.55) and substantial (kappa = 0.62), respectively. Urine-based carcinogenic HPV detection had a clinical sensitivity of 80.8% (95% confidence interval [CI] = 60.7 to 93.5) and a specificity of 53.3% (95% CI = 37.9 to 68.3) for diagnosing cervical intraepithelial neoplasia grades 2/3 (CIN2/3) on histology; 90.0% of CIN3 was positive for urine HPV. The corresponding sensitivity and specificity values for vulvar sampling were 92% (95% CI = 74 to 99) and 40.5% (95% CI = 25.6 to 56.7), and those for cervical sampling were 96.2% (95% CI = 80.4 to 99.9) and 40% (95% CI = 25.7 to 55.7), respectively. HPV16 was the most common carcinogenic genotype detectable in 25% of urine, 33.8% of vulvar, and 31.9% of cervical samples overall, with prevalence increasing with cervical disease grade, regardless of the sampling method. Stronger cervical HPV PCR signal strengths were associated with increased frequency of urine HPV detection. In summary, the relatively lower detection rates but comparable clinical performance of urine-based HPV sampling underscore the need for larger studies to evaluate urine-based sampling for cervical cancer screening, epidemiologic studies, and postvaccination HPV disease surveillance. PMID:24197879

  20. Effect of Shift Work on Nocturia.

    PubMed

    Kim, Jin Wook

    2016-01-01

    To identify the circadian sensitive component of nocturia by comparing nocturia in patients who voluntarily choose a disrupted circadian rhythm, that is, shift workers, with those who maintain normal day-night cycles. Between 2011 and 2013, a total of 1741 untreated patients, 1376 nonshift workers and 365 shift workers, were compared for nocturia indices based on frequency volume charts (FVCs). General linear model of 8-hour interval urine production and frequency were compared between FVCs of nonshift workers, FVCs of night-shift workers, and FVCs of day-shift workers. Nocturia frequency was increased in the night-shift workers (2.38 ± 1.44) compared with nonshift workers (2.18 ± 1.04) (P <.01). Whereas nocturnal polyuria index did not increase significantly (0.33 ± 0.19 for night-shift workers, 0.34 ± 0.13 for nonshift workers, P = .24), nocturnal bladder capacity index increased significantly (1.41 ± 1.06 for night-shift workers, 1.26 ± 0.92 for nonshift workers, P <.01). Eight-hour interval indices show that urine production changed with shift (P <.01), whereas voiding frequency remains unchanged despite shift changes (P = .35). Patients in alternating work shifts showed increased nocturia, especially during their night shift. These changes tended to be more associated with decreased nocturnal bladder capacity than increased nocturnal polyuria. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    PubMed

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Optimization of HPV DNA detection in urine by improving collection, storage, and extraction.

    PubMed

    Vorsters, A; Van den Bergh, J; Micalessi, I; Biesmans, S; Bogers, J; Hens, A; De Coster, I; Ieven, M; Van Damme, P

    2014-11-01

    The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.

  3. Stereometabolism of ethylbenzene in man: gas chromatographic determination of urinary excreted mandelic acid enantiomers and phenylglyoxylic acid and their relation to the height of occupational exposure.

    PubMed

    Korn, M; Gfrörer, W; Herz, R; Wodarz, I; Wodarz, R

    1992-01-01

    Ethylbenzene is an important industrial solvent and a key substance in styrene production. Ethylbenzene metabolism leads to the formation of mandelic acid, which occurs in two enantiomeric forms, and phenylglyoxylic acid. To decide which enantiomer is preferably formed, 70 urine samples of exposed workers were taken at the end of shifts and--after 3-pentyl ester derivatisation--gas chromatographically analysed. The R/S ratio of mandelic acid enantiomers in urine amounts to 19:1, which means that R-mandelic acid is a major metabolite and S-mandelic acid is one of the minor urinary metabolites of ethylbenzene in man. The R/S ratio is independent of ambient air concentration of ethylbenzene within the investigated range. Compared to an ethylbenzene monoexposure the height of total mandelic acid excretion is decreased in the case of coexposure to other aromatic solvents.

  4. Design and use of mouse control DNA for DNA biomarker extraction and PCR detection from urine: application for transrenal Mycobacterium tuberculosis DNA detection

    PubMed Central

    Bordelon, Hali; Ricks, Keersten M.; Pask, Megan E.; Russ, Patricia K.; Solinas, Francesca; Baglia, Mark L.; Short, Philip A.; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W.; Haselton, Frederick R.; Pettit, April C.

    2017-01-01

    Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1 milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5 mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found a increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. PMID:28285168

  5. Design and use of mouse control DNA for DNA biomarker extraction and PCR detection from urine: Application for transrenal Mycobacterium tuberculosis DNA detection.

    PubMed

    Bordelon, Hali; Ricks, Keersten M; Pask, Megan E; Russ, Patricia K; Solinas, Francesca; Baglia, Mark L; Short, Philip A; Nel, Andrew; Blackburn, Jonathan; Dheda, Keertan; Zamudio, Carlos; Cáceres, Tatiana; Wright, David W; Haselton, Frederick R; Pettit, April C

    2017-05-01

    Urine samples are increasingly used for diagnosing infections including Escherichia coli, Ebola virus, and Zika virus. However, extraction and concentration of nucleic acid biomarkers from urine is necessary for many molecular detection strategies such as polymerase chain reaction (PCR). Since urine samples typically have large volumes with dilute biomarker concentrations making them prone to false negatives, another impediment for urine-based diagnostics is the establishment of appropriate controls particularly to rule out false negatives. In this study, a mouse glyceraldehyde 3-phosphate dehydrogenase (GAPDH) DNA target was added to retrospectively collected urine samples from tuberculosis (TB)-infected and TB-uninfected patients to indicate extraction of intact DNA and removal of PCR inhibitors from urine samples. We tested this design on surrogate urine samples, retrospective 1milliliter (mL) urine samples from patients in Lima, Peru and retrospective 5mL urine samples from patients in Cape Town, South Africa. Extraction/PCR control DNA was detectable in 97% of clinical samples with no statistically significant differences among groups. Despite the inclusion of this control, there was no difference in the amount of TB IS6110 Tr-DNA detected between TB-infected and TB-uninfected groups except for samples from known HIV-infected patients. We found an increase in TB IS6110 Tr-DNA between TB/HIV co-infected patients compared to TB-uninfected/HIV-infected patients (N=18, p=0.037). The inclusion of an extraction/PCR control DNA to indicate successful DNA extraction and removal of PCR inhibitors should be easily adaptable as a sample preparation control for other acellular sample types. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Exposure to MTBE, TAME and aromatic hydrocarbons during gasoline pump maintenance, repair and inspection.

    PubMed

    Vainiotalo, Sinikka; Kuusimäki, Leea; Pekari, Kaija

    2006-09-01

    The exposure of gasoline pump repairers and inspectors to gasoline was studied at service stations and repair shops in Finland in April-June 2004. The average air temperature ranged from 7 degrees C to 16 degrees C and wind speed from 2.5 to 7 m/s. The gasoline blends contained mixtures of methyl tert-butyl ether (MTBE) and tert-amyl methyl ether (TAME), the total content of oxygenates being 11-12%. The content of benzene was <1%. Breathing zone air was collected during the work task using passive monitors. The mean sampling period was 4.5 h. The mean TWA-8 h concentrations for MTBE, TAME, hexane, benzene, toluene, ethylbenzene and xylene were 4.5, 1.3, 0.55, 0.23, 2.2, 0.26 and 1.1 mg/m3, respectively. None of the individual benzene concentrations exceeded the binding limit value for benzene (3.25 mg/m3). The sum concentration of MTBE and TAME in urine was between 8.9 and 530 nmol/l in individual post-shift samples. The individual sum concentrations of the metabolites tert-butyl alcohol and tert-amyl alcohol collected the following morning after the exposure ranged from 81 to 916 nmol/l. All individual results were below corresponding biological action levels. Exposure to aromatic hydrocarbons was estimated from post-shift urine samples, with benzene showing the highest concentration (range 4.4 and 35 nmol/l in non-smokers). The exposure levels were similar to those measured in previous studies during unloading of tanker lorries and railway wagons. The results indicated a slightly higher exposure for inspectors, who calibrated fuel pump gauges at the service stations, than for pump repairers. No significant skin exposure occurred during the study.

  7. n-Hexane metabolism in occupationally exposed workers.

    PubMed Central

    Mutti, A; Falzoi, M; Lucertini, S; Arfini, G; Zignani, M; Lombardi, S; Franchini, I

    1984-01-01

    Lung uptake and excretion of n-hexane were studied in ten workers in a shoe factory. Simultaneous samples of inhaled and alveolar air were collected with the aid of a Rhan-Otis valve, personal samplers, and charcoal tubes. Alveolar excretion was monitored during a six hour postexposure period. Uptake was calculated from lung ventilation, the retention coefficient, and environmental concentrations. The amount of exhaled n-hexane was calculated from the decay curve. According to the experimental data, alveolar retention was about 25% of the inhaled n-hexane, corresponding to a lung uptake of about 17%. The postexposure alveolar excretion was about 10% of the total uptake. The main metabolites of n-hexane were identified and measured by capillary GC/MS in spot urine samples collected before, at the end, and 15 hours after the same working shift. Urinary concentrations were low, though related to n-hexane in the air. 2,5-Hexanedione in the end of shift samples gave the best estimate of overall exposure. About 3 mg/g creatinine of 2,5-hexanedione would correspond to about 50 ppm of n-hexane in the air (mean daily exposure). PMID:6498115

  8. Should acidification of urine be performed before the analysis of calcium, phosphate and magnesium in the presence of crystals?

    PubMed

    Pratumvinit, Busadee; Reesukumal, Kanit; Wongkrajang, Preechaya; Khejonnit, Varanya; Klinbua, Cherdsak; Dangneawnoi, Weerapol

    2013-11-15

    Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples. From 130 urine samples obtained via routine urine analysis, 65 (50%) samples were classified as non-crystallized. All samples were divided into three groups: untreated samples, acidified samples with HCl, and acidified samples after 1h room-temperature incubation. Urine samples were measured for calcium, phosphate, magnesium, and creatinine using Modular P800 and were examined for crystals using light microscopy. In crystallized samples, acidified samples with 1h incubation had significantly higher Ca/Cr, P/Cr, and Mg/Cr than did untreated samples with mean differences of 0.04, 0.03, and 0.01 mg/mg, respectively (P<0.001). In acidified samples that were analyzed immediately, crystallized samples had lower calcium concentrations than those of acidified samples with 1h incubation and a mean difference of 0.21 mg/dl (P = 0.025). None of the sample differences which exceeded the critical difference of urinary Ca, P and Mg was observed. Acidification of urine should be performed before the measurement of Ca, P, and Mg in the presence of urinary crystals. However, the lack of an acidification process does not result in a clinically significant change. © 2013.

  9. Urine osmolality in the US population: Implications for environmental biomonitoring

    PubMed Central

    Yeh, Hung-Chieh; Lin, Yu-Sheng; Kuo, Chin-Chi; Weidemann, Darcy; Weaver, Virginia; Fadrowski, Jeffrey; Neu, Alicia; Navas-Acien, Ana

    2018-01-01

    Background For many environmental chemicals, concentrations in spot urine samples are considered valid surrogates of exposure and internal dose. To correct for urine dilution, spot urine concentrations are commonly adjusted for urinary creatinine. There are, however, several concerns about the use of urine creatinine. While urine osmolality is an attractive alternative; its characteristics and determinants in the general population remain unknown. Our objective was to describe the determinants of urine osmolality and to contrast the difference between osmolality and creatinine in urine. Methods From the National Health and Nutrition Examination Survey (NHANES) 2009–2012, 10,769 participants aged 16 years or older with measured urine osmolality and creatinine were used in the analysis. Very dilute and very concentrated urine was defined as urine creatinine lower than 0.3 g/l and higher than 3 g/l, respectively. Linear and logistic regression analyses were performed to investigate the associations of interest. Results Urine osmolality and creatinine were highly correlated (Pearson correlation coefficient = 0.75) and their respective median values were 648 mOsm/kg and 1.07 g/l. The prevalence of very dilute and very concentrated urine samples was 8.1% and 3.1%, respectively. Factors associated in the same direction with both urine osmolality and urine creatinine included age, sex, race, body mass index (BMI), hypertension, water intake, and blood osmolality. The magnitude of associations expressed as percent change was significantly stronger with creatinine than osmolality. Compared to urine creatinine, urine osmolality did not vary by diabetes status but was affected by daily total protein intake. Participants with chronic kidney disease (CKD) had significantly higher urine creatinine concentrations but lower urine osmolality. Both very dilute and concentrated urine were associated with a diverse array of sociodemographic, medical conditions, and dietary factors. For instance, females were approximately 3.3 times more likely to have urine over-dilution than male [the adjusted odds ratios (95% CI) = 3.27 (2.10–5.10)]. Conclusion Although the determinants of urine osmolality were generally similar to those of urine creatinine, the relative influence of socio-demographic and medical conditions was less on urine osmolality than on urine creatinine. Protocols for spot urine sample collection could recommend avoiding excessive and insufficient water intake before urine sampling to improve urine adequacy. The feasibility of adopting urine osmolality adjustment and water intake recommendations before providing spot urine samples for environmental biomonitoring merits further investigation. PMID:25460670

  10. Comparing Urinary Biomarkers of Airborne and Dermal Exposure to Polycyclic Aromatic Compounds in Asphalt-Exposed Workers

    PubMed Central

    Sobus, Jon R.; McClean, Michael D.; Herrick, Robert F.; Waidyanatha, Suramya; Nylander-French, Leena A.; Kupper, Lawrence L.; Rappaport, Stephen M.

    2009-01-01

    When working with hot mix asphalt, road pavers are exposed to polycyclic aromatic hydrocarbons (PAHs) through the inhalation of vapors and particulate matter (PM) and through dermal contact with PM and contaminated surfaces. Several PAHs with four to six rings are potent carcinogens which reside in these particulate emissions. Since urinary biomarkers of large PAHs are rarely detectable in asphalt workers, attention has focused upon urinary levels of the more volatile and abundant two-ring and three-ring PAHs as potential biomarkers of PAH exposure. Here, we compare levels of particulate polycyclic aromatic compounds (P-PACs, a group of aromatic hydrocarbons containing PAHs and heterocyclic compounds with four or more rings) in air and dermal patch samples from 20 road pavers to the corresponding urinary levels of naphthalene (U-Nap) (two rings), phenanthrene (U-Phe) (three rings), monohydroxylated metabolites of naphthalene (OH-Nap) and phenanthrene (OH-Phe), and 1-hydroxypyrene (OH-Pyr) (four rings), the most widely used biomarker of PAH exposure. For each worker, daily breathing-zone air (n = 55) and dermal patch samples (n = 56) were collected on three consecutive workdays along with postshift, bedtime, and morning urine samples (n = 149). Measured levels of P-PACs and the urinary analytes were used to statistically model exposure–biomarker relationships while controlling for urinary creatinine, smoking status, age, body mass index, and the timing of urine sampling. Levels of OH-Phe in urine collected postshift, at bedtime, and the following morning were all significantly associated with levels of P-PACs in air and dermal patch samples. For U-Nap, U-Phe, and OH-Pyr, both air and dermal patch measurements of P-PACs were significant predictors of postshift urine levels, and dermal patch measurements were significant predictors of bedtime urine levels (all three analytes) and morning urine levels (U-Nap and OH-Pyr only). Significant effects of creatinine concentration were observed for all analytes, and modest effects of smoking status and body mass index were observed for U-Phe and OH-Pyr, respectively. Levels of OH-Nap were not associated with P-PAC measurements in air or dermal patch samples but were significantly affected by smoking status, age, day of sample collection, and urinary creatinine. We conclude that U-Nap, U-Phe, OH-Phe, and OH-Pyr can be used as biomarkers of exposure to particulate asphalt emissions, with OH-Phe being the most promising candidate. Indications that levels of U-Nap, U-Phe, and OH-Pyr were significantly associated with dermal patch measurements well into the evening after a given work shift, combined with the small ratios of within-person variance components to between-person variance components at bedtime, suggest that bedtime measurements may be useful for investigating dermal PAH exposures. PMID:19602502

  11. Reliable Quantification of the Potential for Equations Based on Spot Urine Samples to Estimate Population Salt Intake: Protocol for a Systematic Review and Meta-Analysis.

    PubMed

    Huang, Liping; Crino, Michelle; Wu, Jason Hy; Woodward, Mark; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Nowson, Caryl A; Elliott, Paul; Cogswell, Mary; Toft, Ulla; Mill, Jose G; Furlanetto, Tania W; Ilich, Jasminka Z; Hong, Yet Hoi; Cohall, Damian; Luzardo, Leonella; Noboa, Oscar; Holm, Ellen; Gerbes, Alexander L; Senousy, Bahaa; Pinar Kara, Sonat; Brewster, Lizzy M; Ueshima, Hirotsugu; Subramanian, Srinivas; Teo, Boon Wee; Allen, Norrina; Choudhury, Sohel Reza; Polonia, Jorge; Yasuda, Yoshinari; Campbell, Norm Rc; Neal, Bruce; Petersen, Kristina S

    2016-09-21

    Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. The aim of this study is to identify a reliable method for estimating mean population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status, and timing of spot urine collection will be explored. The capacity of spot urine samples to measure change in salt intake over time will also be determined. Finally, we aim to develop a novel equation (or equations) that performs better than existing equations to estimate mean population salt intake. A systematic review and meta-analysis of individual participant data will be conducted. A search has been conducted to identify human studies that report salt (or sodium) excretion based upon 24-hour urine samples and spot urine samples. There were no restrictions on language, study sample size, or characteristics of the study population. MEDLINE via OvidSP (1946-present), Premedline via OvidSP, EMBASE, Global Health via OvidSP (1910-present), and the Cochrane Library were searched, and two reviewers identified eligible studies. The authors of these studies will be invited to contribute data according to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical characteristics; (2) assess the reliability of using spot urine samples to measure population changes in salt intake overtime; and (3) develop a novel equation that performs better than existing equations to estimate mean population salt intake. The search strategy identified 538 records; 100 records were obtained for review in full text and 73 have been confirmed as eligible. In addition, 68 abstracts were identified, some of which may contain data eligible for inclusion. Individual participant data will be requested from the authors of eligible studies. Many equations for estimating salt intake from spot urine samples have been developed and validated, although most have been studied in very specific settings. This meta-analysis of individual participant data will enable a much broader understanding of the capacity for spot urine samples to estimate population salt intake.

  12. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    PubMed

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of sequestering contaminants from environmental release and allows for targeted treatment of potential health hazards prior to agricultural application. The efficacy of pathogen and pharmaceutical inactivation, transformation or removal during urine nutrient recovery processes is thus briefly reviewed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Exposure to BTEX and Ethers in Petrol Station Attendants and Proposal of Biological Exposure Equivalents for Urinary Benzene and MTBE.

    PubMed

    Campo, Laura; Rossella, Federica; Mercadante, Rosa; Fustinoni, Silvia

    2016-04-01

    To assess exposure to benzene (BEN) and other aromatic compounds (toluene, ethylbenzene, m+p-xylene, o-xylene) (BTEX), methyl tert-butyl ether (MTBE), and ethyl tert-butyl ether (ETBE) in petrol station workers using air sampling and biological monitoring and to propose biological equivalents to occupational limit values. Eighty-nine petrol station workers and 90 control subjects were investigated. Personal exposure to airborne BTEX and ethers was assessed during a mid-week shift; urine samples were collected at the beginning of the work week, prior to and at the end of air sampling. Petrol station workers had median airborne exposures to benzene and MTBE of 59 and 408 µg m(-3), respectively, with urinary benzene (BEN-U) and MTBE (MTBE-U) of 339 and 780 ng l(-1), respectively. Concentrations in petrol station workers were higher than in control subjects. There were significant positive correlations between airborne exposure and the corresponding biological marker, with Pearson's correlation coefficient (r) values of 0.437 and 0.865 for benzene and MTBE, respectively. There was also a strong correlation between airborne benzene and urinary MTBE (r = 0.835). Multiple linear regression analysis showed that the urinary levels of benzene were influenced by personal airborne exposure, urinary creatinine, and tobacco smoking [determination coefficient (R(2)) 0.572], while MTBE-U was influenced only by personal exposure (R(2) = 0.741). BEN-U and MTBE-U are sensitive and specific biomarkers of low occupational exposures. We propose using BEN-U as biomarker of exposure to benzene in nonsmokers and suggest 1457 ng l(-1) in end shift urine samples as biological exposure equivalent to the EU occupational limit value of 1 p.p.m.; for both smokers and nonsmokers, MTBE-U may be proposed as a surrogate biomarker of benzene exposure, with a biological exposure equivalent of 22 µg l(-1) in end shift samples. For MTBE exposure, we suggest the use of MTBE-U with a biological exposure equivalent of 22 µg l(-1) corresponding to the occupational limit value of 50 p.p.m. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  14. Urinary excretion of the metabolites of n-hexane and its isomers during occupational exposure.

    PubMed Central

    Perbellini, L; Brugnone, F; Faggionato, G

    1981-01-01

    Environmental exposure to commercial hexane (n-hexane, 2-methylpentane, and 3-methylpentane) was tested in several work places in five shoe factories by taking three grap-air samples during the afternoon shift. Individual exposure ranges were 32-500 mg/m3 for n-hexane, 11-250 mg/m3 for 2-methylpentane, and 10-204 mg/m3 for 3-methylpentane. The metabolites of commercial hexane in the urine of 41 workers were measured at the end of the work shift. 2-Hexanol, 2,5-hexanedione, 2,5-dimethylfuran, and gamma-valerolactone were found as n-hexane metabolites and 2-methyl-2-pentanol and 3-methyl-2-pentanol as 2-methylpentane and 3-methylpentane metabolites. The presence of metabolites in the urine was correlated with occupational exposure to solvents. n-Hexane exposure was correlated more positively with 2-hexanol and 2,5-hexanedione than with 2,5-dimethylfuran and gamma-valerolactone. A good correlation was also found between total n-hexane metabolites and n-hexane exposure. 2-Methyl-2-pentanol and 3-methyl-2-pentanol were highly correlated with 2-methylpentane and 3-methylpentane exposure. The results suggest that the urinary excretion of hexane metabolites may be used for monitoring occupational exposure to n-hexane and its isomers. PMID:7470400

  15. Comparison between Indirect Immunofluorescence Assay and Shell Vial Culture for Detection of Mumps Virus from Clinical Samples

    PubMed Central

    Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita

    2003-01-01

    We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158

  16. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. ©2016 American Association for Cancer Research.

  17. Urine output on an intensive care unit: case-control study

    PubMed Central

    Kirwan, Christopher J; Alexander, Neal D E; Nimako, Kofi; Jurukov, Angela; Forth, Rebecca J; Rahman, Tony M

    2010-01-01

    Objective To compare urine output between junior doctors in an intensive care unit and the patients for whom they are responsible. Design Case-control study. Setting General intensive care unit in a tertiary referral hospital. Participants 18 junior doctors responsible for clerking patients on weekday day shifts in the unit from 23 March to 23 April 2009 volunteered as “cases.” Controls were the patients in the unit clerked by those doctors. Exclusion criteria (for both groups) were pregnancy, baseline estimated glomerular filtration rate <15 ml/min/1.73 m2, and renal replacement therapy. Main outcome measures Oliguria (defined as mean urine output <0.5 ml/kg/hour over six or more hours of measurement) and urine output (in ml/kg/hour) as a continuous variable. Results Doctors were classed as oliguric and “at risk” of acute kidney injury on 19 (22%) of 87 shifts in which urine output was measured, and oliguric to the point of being “in injury” on one (1%) further shift. Data were available for 208 of 209 controls matched to cases in the data collection period; 13 of these were excluded because the control was receiving renal replacement therapy. Doctors were more likely to be oliguric than their patients (odds ratio 1.99, 95% confidence interval 1.08 to 3.68, P=0.03). For each additional 1 ml/kg/hour mean urine output, the odds ratio for being a case rather than a control was 0.27 (0.12 to 0.58, P=0.001). Mortality among doctors was astonishingly low, at 0% (0% to 18%). Conclusions Managing our own fluid balance is more difficult than managing it in our patients. We should drink more water. Modifications to the criteria for acute kidney injury could be needed for the assessment of junior doctors in an intensive care unit. PMID:21156738

  18. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    PubMed

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  19. Long-term frozen storage of urine samples: a trouble to get PCR results in Schistosoma spp. DNA detection?

    PubMed

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples' storage or conditions for handling and DNA preservation and extraction methods. We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patients urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used.

  20. The impact of chronotype on melatonin levels among shift workers.

    PubMed

    Bhatti, Parveen; Mirick, Dana K; Davis, Scott

    2014-03-01

    The association between shift work and cancer, which is thought to be mediated by effects on circulating melatonin levels, may be modified by chronotype (ie, the inherent preference for activity in the morning or the evening); however, few studies have examined the potential impact of chronotype on the carcinogenic effects of shift work. The authors analysed the impact of chronotype on previously reported differences in melatonin levels among healthcare workers that exclusively worked night or day shifts. The cross-sectional study included 664 men and women (310 day shift and 354 night shift workers) from which urine samples were collected throughout work and sleep periods and were assayed for 6-sulfatoxymelatonin. Participants also completed the Composite Scale of Morningness, a questionnaire used to assess chronotype. Among both morning and evening-type night shift workers, 6-sulfatoxymelatonin levels were constitutively lower during daytime sleep, night-time sleep and night work compared with day shift workers during night-time sleep. However, morning-type night shift workers consistently showed 6-sulfatoxymelatonin levels that were closer to levels in day shift workers than did evening-type night shift workers. Differences in 6-sulfatoxymelatonin levels between morning-type and evening-type night shift workers relative to day shift workers were statistically significant in every instance (p<0.05). These results suggest that morning-type night shift workers may be better able to maintain a 'normal' circadian pattern of melatonin production as compared with evening-type night shift workers. The impact of this chronotype effect on cancer risk among shift workers requires further study.

  1. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    PubMed

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  2. Exposure to mutagenic chemicals in foundry and urban environments.

    PubMed

    Barański, B; Palus, J; Janik-Spiechowicz, E

    1989-01-01

    The study was aimed at the estimation of occupational exposure to mutagenic substances in a piston-ring foundry. The following samples were examined: solid phase of aerosol from the foundry and from different places of urban environment together with the foundry workers' urine collected during the 8-hour shift. The mutagenic substances were extracted from the collected material with acetone or concentrated with XAD-2 resin. The mutagenic property was estimated with the Ames' test using S. typhimurium strain TA98 without and with S9 fraction. The highest mutagenic activity was found at the following work-posts: caster, moulder, steerer of an induction furnace, and smelter and in the office rooms and in the flat occupied by heavy smokers. The mutagenic activity of aerosol at some other productive workposts in the foundry was similar to the mutagenic activity of aerosol in the office and flat rooms occupied by nonsmokers or in the street in Lodz. The mutagenic activity of urine from foundry workers was not correlated with the level of the occupational inhalation exposure to the mutagenic substances, however, the mutagenic activity of urine from smoking workers was about 10-20 times higher than from nonsmokers.

  3. Ethion exposure and biological monitoring in vegetable farmers.

    PubMed

    Kongtip, Pornpimol; Changfuang, Sirinnapa; Yoosook, Witaya; Chantanakul, Suttinun; Sujirarat, Dusit

    2011-03-01

    To modify the method of analysis of urinary diethyl phosphate (DEP) in order to determine the relationship between atmospheric ethion concentration and urinary DEP concentration. A cross-sectional study was conducted by collecting atmospheric ethion in the breathing zone of 28 farmers following the NIOSH 5600 method. Urine samples were also collected to analyze urinary DEP concentrations by a modified method using a Gas Chromatography-Flame Photometric Detector (FPD). The average atmospheric ethion concentration in the breathing zone of farmers was 0.036 +/- 0.018 mg/m3. The average urinary DEP in pre-shift and post-shift was 0.030 +/- 0.06 and 0.851 +/- 1.80 mg/g of creatinine respectively. The average DEP during work shifts was 0.53 +/- 0.27, and ranged from 0.12 to 1.16 mg/g of creatinine. A high correlation coefficient (r = 0.645) was found between atmospheric ethion concentrations and urinary DEP concentrations at p < 0.001. The modified method provided a reliable result and the urinary DEP during work shifts was found to be a reliable biomarker of ethion exposure.

  4. Effect of urine creatinine level during pregnancy on dipstick test.

    PubMed

    Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori

    2017-06-01

    Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.

  5. Prevalence of urinary tract infection (UTI) in sequential acutely unwell children presenting in primary care: exploratory study.

    PubMed

    O'Brien, Kathryn; Stanton, Naomi; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C

    2011-03-01

    Due to the non-specific nature of symptoms of UTI in children and low levels of urine sampling, the prevalence of UTI amongst acutely ill children in primary care is unknown. To undertake an exploratory study of acutely ill children consulting in primary care, determine the feasibility of obtaining urine samples, and describe presenting symptoms and signs, and the proportion with UTI. Exploratory, observational study. Four general practices in South Wales. A total of 99 sequential attendees with acute illness aged less than five years. UTI defined by >10(5) organisms/ml on laboratory culture of urine. Urine samples were obtained in 75 (76%) children. Three (4%) met microbiological criteria for UTI. GPs indicated they would not normally have obtained urine samples in any of these three children. However, all had received antibiotics for suspected alternative infections. Urine sample collection is feasible from the majority of acutely ill children in primary care, including infants. Some cases of UTI may be missed if children thought to have an alternative site of infection are excluded from urine sampling. A larger study is needed to more accurately determine the prevalence of UTI in children consulting with acute illness in primary care, and to explore which symptoms and signs might help clinicians effectively target urine sampling.

  6. Critical study of common conditions of storage of glucocorticoids and catecholamines in 24-h urine collected during resting and exercising conditions.

    PubMed

    Gouarne, C; Foury, A; Duclos, M

    2004-10-01

    Except immediate freezing of the samples, no practical method has been validated for preservation of glucocorticoids and catecholamines in 24-h urine collection. Furthermore, the influence of urine storage at bladder temperature during periods of different lengths and the effect of prior exercise on preservation of these hormones in the bladder have not been investigated until now. Ten healthy volunteers collected their urine both after a resting and after an exercise session. Urine was aliquoted into tubes which were stored during 24 h in the presence or in the absence of preservatives and at different temperatures. Two samples were stored either 3 or 9 h at 37 degrees C (bladder temperature) without additive. When collecting 24-h urine samples for glucocorticoids determination, sample can be stored at room temperature during the 24-h collection period without compromising glucocorticoids preservation. When collecting 24-h urine samples for catecholamines determination, samples have to be chilled without preservative during the whole of the collection period. If the samples have to be stored at room temperature, HCl should be used. Moreover, we report for the first time that catecholamines can be degraded in the bladder and therefore that subjects should urinate every 3 h during either a resting or an exercising day.

  7. Long-Term Frozen Storage of Urine Samples: A Trouble to Get PCR Results in Schistosoma spp. DNA Detection?

    PubMed Central

    Fernández-Soto, Pedro; Velasco Tirado, Virginia; Carranza Rodríguez, Cristina; Pérez-Arellano, José Luis; Muro, Antonio

    2013-01-01

    Background Human schistosomiasis remains a serious worldwide public health problem. At present, a sensitive and specific assay for routine diagnosis of schistosome infection is not yet available. The potential for detecting schistosome-derived DNA by PCR-based methods in human clinical samples is currently being investigated as a diagnostic tool with potential application in routine schistosomiasis diagnosis. Collection of diagnostic samples such as stool or blood is usually difficult in some populations. However, urine is a biological sample that can be collected in a non-invasive method, easy to get from people of all ages and easy in management, but as a sample for PCR diagnosis is still not widely used. This could be due to the high variability in the reported efficiency of detection as a result of the high variation in urine samples’ storage or conditions for handling and DNA preservation and extraction methods. Methodology/Principal Findings We evaluate different commercial DNA extraction methods from a series of long-term frozen storage human urine samples from patients with parasitological confirmed schistosomiasis in order to assess the PCR effectiveness for Schistosoma spp. detection. Patientś urine samples were frozen for 18 months up to 7 years until use. Results were compared with those obtained in PCR assays using fresh healthy human urine artificially contaminated with Schistosoma mansoni DNA and urine samples from mice experimentally infected with S. mansoni cercariae stored frozen for at least 12 months before use. PCR results in fresh human artificial urine samples using different DNA based extraction methods were much more effective than those obtained when long-term frozen human urine samples were used as the source of DNA template. Conclusions/Significance Long-term frozen human urine samples are probably not a good source for DNA extraction for use as a template in PCR detection of Schistosoma spp., regardless of the DNA method of extraction used. PMID:23613907

  8. Airborne exposure and biological monitoring of bar and restaurant workers before and after the introduction of a smoking ban.

    PubMed

    Ellingsen, Dag G; Fladseth, Geir; Daae, Hanne L; Gjølstad, Merete; Kjaerheim, Kristina; Skogstad, Marit; Olsen, Raymond; Thorud, Syvert; Molander, Paal

    2006-03-01

    The aims were to assess the impact of a total smoking ban on the level of airborne contaminants and the urinary cotinine levels in the employees in bars and restaurants. In a follow up design, 13 bars and restaurants were visited before and after the implementation of a smoking ban. Ninety-three employees in the establishments were initially included into the study. The arithmetic mean concentration of nicotine and total dust declined from 28.3 microg m(-3) (range, 0.4-88.0) and 262 microg m(-3) (range, 52-662), respectively, to 0.6 microg m(-3) (range, not detected-3.7) and 77 microg m(-3) (range, not detected-261) after the smoking ban. The Pearson correlation coefficient between airborne nicotine and total dust was 0.86 (p < 0.001; n = 48). The post-shift geometric mean urinary cotinine concentration declined from 9.5 microg g(-1) creatinine (cr) (95% CI 6.5-13.7) to 1.4 microg g(-1) cr (95% CI 0.8-2.5) after the ban (p < 0.001) in 25 non-snuffing non-smokers. A reduction from 1444 microg g(-1) cr (95% CI 957-2180) to 688 microg g(-1) cr (95% CI 324-1458) was found (p < 0.05) in 29 non-snuffing smokers. The urinary cotinine levels increased from 11.7 microg g(-1) cr (95% CI 7.0-19.6) post-shift to 21.9 microg g(-1) cr (95% CI 13.3-36.3) (p < 0.01) in the next morning in 24 non-snuffing non-smokers before the smoking ban. A substantial reduction of airborne nicotine and total dust was observed after the introduction of a smoking ban in bars and restaurants. The urinary cotinine levels were reduced in non-smokers. The decline found in smokers may suggest a reduction in the amount of smoking after intervention. In non-smokers cotinine concentrations were higher based on urine sampled the morning after a shift than based on urine sampled immediately post-shift.

  9. The Impact of Chronotype on Melatonin Levels Among Shift Workers

    PubMed Central

    Bhatti, Parveen; Mirick, Dana K.; Davis, Scott

    2015-01-01

    Objectives The association between shift work and cancer, which is thought to be mediated by effects on circulating melatonin levels, may be modified by chronotype (i.e. the inherent preference for activity in the morning or the evening); however, few studies have examined the potential impact of chronotype on the carcinogenic effects of shift work. The authors analyzed the impact of chronotype on previously reported differences in melatonin levels among healthcare workers that exclusively worked night or day shifts. Methods The cross-sectional study included 664 men and women (310 day shift and 354 night shift workers) from which urine samples were collected throughout work and sleep periods and were assayed for 6-sulfatoxymelatonin. Participants also completed the Composite Scale of Morningness, a questionnaire used to assess chronotype. Results Among both morning and evening-type night shift workers, 6-sulfatoxymelatonin levels were constitutively lower during daytime sleep, nighttime sleep and night work compared to dayshift workers during nighttime sleep. However, morning-type shift workers consistently showed 6-sulfatoxymelatonin levels that were closer to levels in day shift workers than did evening-type night shift workers. Differences in 6-sulfatoxymelatonin levels between morning-type and evening-type night shift workers relative to day shift workers were statistically significant in every instance (p < 0.05). Conclusion These results suggest that morning-type night shift workers may be better able to maintain a ‘normal’ circadian pattern of melatonin production as compared to evening-type night shift workers. The impact of this chronotype effect on cancer risk among shift workers requires further study. PMID:24399070

  10. Association between exposure to rotating night shift versus day shift using levels of 6-sulfatoxymelatonin and cortisol and other sex hormones in women.

    PubMed

    Gómez-Acebo, Inés; Dierssen-Sotos, Trinidad; Papantoniou, Kyriaki; García-Unzueta, María Teresa; Santos-Benito, María Francisca; Llorca, Javier

    2015-02-01

    The present study aims to compare 6-sulfatoxymelatonin (aMT6s) secretion patterns and levels of cortisol and sex hormones (estradiol, progesterone, DHEA, DHEAS, and testosterone) among rotating night-shift workers and day-shift workers. We performed a cross-sectional study in Cantabria (northern Spain) including 136 women (73 day-shift workers and 63 rotating night-shift workers). Blood and urine samples were obtained after two consecutive working days. Differences in means were estimated using ANCOVA, stratified by menopausal status, ovulation phase, and adjusted for season, age, body mass index, consumption of cigarettes in the last 24 h. aMT6s circadian rhythm was analyzed using the cosinor analysis. The present study showed that rotating night-shift workers had lower excretion of aMT6s than day-shift workers (mesor = 50.26 ng aMT6s/mg creatinine in women with rotating night shift versus 88.79 ng aMT6s/mg creatinine in women with day shift), lower fluctuation (amplitude = 45.24 ng aMT6s/mg creatinine in rotating night-shift workers versus 79.71 ng aMT6s/mg creatinine in day-shift workers), and a later acrophase (aMT6s peak time: 08:31 in rotating night-shift workers versus 07:13 h in day-shift workers). Additionally, women with rotating night shift had higher estradiol and progesterone levels, compared to day workers, especially in the follicular phase on the menstrual cycle.

  11. The association of body size in early to mid-life with adult urinary 6-sulfatoxymelatonin levels among night shift health care workers.

    PubMed

    Ramin, Cody A; Massa, Jennifer; Wegrzyn, Lani R; Brown, Susan B; Pierre-Paul, Jeffrey; Devore, Elizabeth E; Hankinson, Susan E; Schernhammer, Eva S

    2015-05-06

    Adult body mass index (BMI) has been associated with urinary melatonin levels in humans; however, whether earlier-life body size is associated with melatonin, particularly among night shift workers, remains unknown. We evaluated associations of birth weight, body shape (or somatotype) at ages 5 and 10, BMI at age 18 and adulthood, weight change since age 18, waist circumference, waist to hip ratio, and height with creatinine-adjusted morning urinary melatonin (6-sulfatoxymelatonin, aMT6s) levels among 1,343 healthy women (aged 32-53 at urine collection, 1996-1999) in the Nurses' Health Study (NHS) II cohort. Using multivariable linear regression, we computed least-square mean aMT6s levels across categories of body size, and evaluated whether these associations were modified by night shift work. Adult BMI was inversely associated with aMT6s levels (mean aMT6s levels = 34 vs. 50 ng/mg creatinine, comparing adult BMI ≥ 30 vs. <20 kg/m(2); P trend < 0.0001); however, other measures of body size were not related to aMT6s levels after accounting for adult BMI. Night shifts worked prior to urine collection, whether recent or cumulatively over time, did not modify the association between adult BMI and aMT6s levels (e.g., P interaction = 0.72 for night shifts worked within two weeks of urine collection). Our results suggest that adult BMI, but not earlier measures of body size, is associated with urinary aMT6s levels in adulthood. These observations did not vary by night shift work status, and suggest that adult BMI may be an important mechanism by which melatonin levels are altered and subsequently influence chronic disease risk.

  12. Comparison of vacuum and non-vacuum urine tubes for urinary sediment analysis.

    PubMed

    Topcuoglu, Canan; Sezer, Sevilay; Kosem, Arzu; Ercan, Mujgan; Turhan, Turan

    2017-12-01

    Urine collection systems with aspiration system for vacuum tubes are becoming increasingly common for urinalysis, especially for microscopic examination of the urine. In this study, we aimed to examine whether vacuum aspiration of the urine sample has any adverse effect on sediment analysis by comparing results from vacuum and non-vacuum urine tubes. The study included totally 213 urine samples obtained from inpatients and outpatients in our hospital. Urine samples were collected to containers with aspiration system for vacuum tubes. Each sample was aliquoted to both vacuum and non-vacuum urine tubes. Urinary sediment analysis was performed using manual microscope. Results were evaluated using chi-square test. Comparison of the sediment analysis results from vacuum and non-vacuum urine tubes showed that results were highly concordant for erythrocyte, leukocyte and epithelial cells (gamma values 1, 0.997, and 0.994, respectively; p < .001). Results were also concordant for urinary casts, crystals and yeast (kappa values 0.815, 0.945 and 1, respectively; p < .001). The results show that in urinary sediment analysis, vacuum aspiration has no adverse effect on the cellular components except on casts.

  13. Urine phenobarbital drug screening: potential use for compliance assessment in neonates.

    PubMed

    Guillet, Ronnie; Kwon, Jennifer M; Chen, Sixaio; McDermott, Michael P

    2012-02-01

    This study was done to determine if urine phenobarbital measurements provide a reliable indicator of presence of the drug in neonates. Urine was collected from neonates treated with phenobarbital for clinical indications within 4 to 6 hours of clinically indicated collection of serum phenobarbital levels. Urine samples were also collected from control neonates not treated with phenobarbital. One aliquot was assayed fresh, another frozen at -30°C and assayed 1 to 3 months later. Phenobarbital was assayed using the ONLINE TDM Roche/Hitachi automated clinical chemistry analyzer. Serum and urine concentrations were compared as were fresh and frozen urine measurements. Serum phenobarbital ranged from 5.6 to 52.7 μg/mL. Matched urine samples were 56.6 ± 12.5% of the serum level. Frozen samples were 98.3 ± 8.0% of the fresh samples. Urine phenobarbital concentrations, either fresh or frozen, can be used in neonates as a noninvasive estimate of drug levels.

  14. The effect of substrate composition and storage time on urine specific gravity in dogs.

    PubMed

    Steinberg, E; Drobatz, K; Aronson, L

    2009-10-01

    The purpose of this study is to evaluate the effects of substrate composition and storage time on urine specific gravity in dogs. A descriptive cohort study of 15 dogs. The urine specific gravity of free catch urine samples was analysed during a 5-hour time period using three separate storage methods; a closed syringe, a diaper pad and non-absorbable cat litter. The urine specific gravity increased over time in all three substrates. The syringe sample had the least change from baseline and the diaper sample had the greatest change from baseline. The urine specific gravity for the litter and diaper samples had a statistically significant increase from the 1-hour to the 5-hour time point. The urine specific gravity from canine urine stored either on a diaper or in a non-absorbable litter increased over time. Although the change was found to be statistically significant over the 5-hour study period it is unlikely to be clinically significant.

  15. Immunoelectrophoresis - urine

    MedlinePlus

    Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... A clean-catch urine sample is needed. The clean-catch method is used to prevent germs from the penis or vagina from getting ...

  16. Consideration of the degree of increase in urine metadrenalines provides superior specificity in the diagnosis of phaeochromocytoma than additional urine catecholamine measurement.

    PubMed

    Scargill, J J; Reed, P; Kane, J

    2013-01-01

    Measurement of fractionated plasma or urine metadrenalines is the recommended screening test in the diagnosis of phaeochromocytoma, with clinical cut-offs geared towards diagnostic sensitivity. Current practice at Salford Royal Hospital is to add urine catecholamines onto samples with raised urine metadrenalines, with the aim of adding specificity to a diagnosis of phaeochromocytoma. This practice was reviewed by identifying a series of patients with raised urine metadrenalines who had catecholamines reflectively added. A total of 358 samples were identified from 242 patients, of which 228 had urine catecholamines measured. A diagnosis of 'phaeochromocytoma' (n = 41) or 'no phaeochromocytoma' (n = 90) was obtained in 131 of 228 patients, giving raised urine metadrenalines a positive predictive value for phaeochromocytoma of 31%. The finding of increased urine catecholamines in samples with raised urine metadrenalines increased specificity for phaeochromocytoma to 70%. However, 95% diagnostic specificity for phaeochromocytoma could be achieved by the introduction of a second cut-off for urine metadrenalines geared towards maximizing specificity. Consideration of the degree of increase in urine metadrenalines is a superior method of determining the likelihood of phaeochromocytoma than measurement of urine catecholamines.

  17. Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.

    PubMed

    Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E

    2002-12-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.

  18. Natural Ca Isotope Composition of Urine as a Rapid Measure of Bone Mineral Balance

    NASA Astrophysics Data System (ADS)

    Skulan, J.; Gordon, G. W.; Morgan, J.; Romaniello, S. J.; Smith, S. M.; Anbar, A. D.

    2011-12-01

    Naturally occurring stable Ca isotope variations in urine are emerging as a powerful tool to detect changes in bone mineral balance. Bone formation depletes soft tissue of light Ca isotopes while bone resorption releases isotopically light Ca into soft tissue. Previously published work found that variations in Ca isotope composition could be detected at 4 weeks of bed rest in a 90-day bed rest study (data collected at 4, 8 and 12 weeks). A new 30-day bed rest study involved 12 patients on a controlled diet, monitored for 7 days prior to bed rest and 7 days post bed rest. Samples of urine, blood and food were collected throughout the study. Four times daily blood samples and per void urine samples were collected to monitor diurnal or high frequency variations. An improved chemical purification protocol, followed by measurement using multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) allowed accurate and precise determinations of mass-dependent Ca isotope variations in these biological samples to better than ±0.2% (δ44/42Ca) on <25 μg of Ca. Results from this new study show that Ca isotope ratios shift in a direction consistent with net bone loss after just 7 days, long before detectible changes in bone density by X-ray measurements occur. Consistent with this interpretation, the Ca isotope variations track changes observed in N-teleopeptide, a bone resorption biomarker. Bone-specific alkaline phosphatase, a bone formation biomarker, is unchanged over this period. Ca isotopes can in principle be used to quantify net changes in bone mass. Using a mass-balance model, our results indicate an average loss of 0.62 ± 0.16 % in bone mass over the course of this 30-day study. This is consistent with the rate of bone loss in longer-term studies as seen by X-ray measurements. This Ca isotope technique should accelerate the pace of discovery of new treatments for bone disease and provide novel insights into the dynamics of bone metabolism.

  19. Immunodetection and molecular determination of visceral and cutaneous Leishmania infection using patients' urine.

    PubMed

    Mirzaei, Asad; Ahmadipour, Fereshteh; Cannet, Arnaud; Marty, Pierre; Delaunay, Pascal; Perrin, Pascale; Dorkeld, Franck; Sereno, Denis; Akhoundi, Mohammad

    2018-05-27

    The diagnosis of leishmaniasis relies mainly on the use of invasive processes, to collect the biological material for detecting Leishmania parasites. Body fluids, which can be collected by non-invasive process, would greatly facilitate the leishmaniasis diagnosis. In the present study, we investigated the potency of urine immunoblotting to diagnose cutaneous and visceral leishmaniasis and we compared with routine molecular methods. A total of 80 samples, including 40 sera and their 40 corresponding urine samples were collected from 37 suspected patients with cutaneous and visceral leishmaniasis, and 3 healthy individuals (as control), in Ilam and Ardabil provinces of Iran. All sera and urine samples were analyzed, using immunoblotting. The confirmation of leishmaniasis infection was performed, using conventional and quantitative PCRs as well as by sequencing the amplicons. Among 37 suspected patients, 23 patients presented cutaneous lesions (CL) and 14 exhibited clinical symptoms reminiscent of visceral leishmaniasis (L. infantum). Among cutaneous patients, 15 were positive for zoonotic cutaneous leishmaniasis (L. major), and eight for anthroponotic cutaneous leishmaniasis (L. tropica). Molecular quantification of Leishmania parasites was performed on sera, urines and cutaneous biopsies of CL and VL patients, demonstrating that parasite load is lower in urines, compared to sera or biopsy. DNA can be detected in 20 out of 23 (86.9%) CL urine samples and in 13 out of 14 (92.8%) VL urine samples. Immunodetection analysis demonstrates that 22 out of 23 (95.6%) sera from CL patients and all patients suspected with VL are positive. For urine samples, 18 out of 23 (78.2%) urine of CL patients and 13 out of 14 (92.8%) urine of VL patients were positive, using Western blot. Therefore, immunodetection and molecular analysis using urine samples can be used as a diagnostic tool for surveying cutaneous and visceral leishmaniasis. Copyright © 2017. Published by Elsevier B.V.

  20. HCG in urine

    MedlinePlus

    Beta-HCG - urine; Human chorionic gonadotropin - urine; Pregnancy test - hCG in urine ... To collect a urine sample, you urinate into a special (sterile) cup. Home pregnancy tests require the test strip to be dipped into ...

  1. Increased and mistimed sex hormone production in night shift workers.

    PubMed

    Papantoniou, Kyriaki; Pozo, Oscar J; Espinosa, Ana; Marcos, Josep; Castaño-Vinyals, Gemma; Basagaña, Xavier; Juanola Pagès, Elena; Mirabent, Joan; Martín, Jordi; Such Faro, Patricia; Gascó Aparici, Amparo; Middleton, Benita; Skene, Debra J; Kogevinas, Manolis

    2015-05-01

    Night shift work has been associated with an increased risk for breast and prostate cancer. The effect of circadian disruption on sex steroid production is a possible underlying mechanism, underinvestigated in humans. We have assessed daily rhythms of sex hormones and melatonin in night and day shift workers of both sexes. We recruited 75 night and 42 day workers, ages 22 to 64 years, in different working settings. Participants collected urine samples from all voids over 24 hours on a working day. Urinary concentrations of 16 sex steroid hormones and metabolites (estrogens, progestagens, and androgens) and 6-sulfatoxymelatonin were measured in all samples. Mean levels and peak time of total and individual metabolite production were compared between night and day workers. Night workers had higher levels of total progestagens [geometric mean ratio (GMR) 1.65; 95% confidence intervals (CI), 1.17-2.32] and androgens (GMR: 1.44; 95% CI, 1.03-2.00), compared with day workers, after adjusting for potential confounders. The increased sex hormone levels among night shift workers were not related to the observed suppression of 6-sulfatoxymelatonin. Peak time of androgens was significantly later among night workers, compared with day workers (testosterone: 12:14 hours; 10:06-14:48 vs. 08:35 hours; 06:52-10:46). We found increased levels of progestagens and androgens as well as delayed peak androgen production in night shift workers compared with day workers. The increase and mistiming of sex hormone production may explain part of the increased risk for hormone-related cancers observed in night shift workers. ©2015 American Association for Cancer Research.

  2. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study

    PubMed Central

    Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I.; Dwyer, Karen M.; Saffery, Richard

    2018-01-01

    Aim To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. Background DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. Methods QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Results Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0–0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0–9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0–17.7μg/mL and 0–1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. Conclusion High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease. PMID:29462136

  3. DNA methylation profiling of genomic DNA isolated from urine in diabetic chronic kidney disease: A pilot study.

    PubMed

    Lecamwasam, Ashani; Sexton-Oates, Alexandra; Carmody, Jake; Ekinci, Elif I; Dwyer, Karen M; Saffery, Richard

    2018-01-01

    To characterise the genomic DNA (gDNA) yield from urine and quality of derived methylation data generated from the widely used Illuminia Infinium MethylationEPIC (HM850K) platform and compare this with buffy coat samples. DNA methylation is the most widely studied epigenetic mark and variations in DNA methylation profile have been implicated in diabetes which affects approximately 415 million people worldwide. QIAamp Viral RNA Mini Kit and QIAamp DNA micro kit were used to extract DNA from frozen and fresh urine samples as well as increasing volumes of fresh urine. Matched buffy coats to the frozen urine were also obtained and DNA was extracted from the buffy coats using the QIAamp DNA Mini Kit. Genomic DNA of greater concentration than 20μg/ml were used for methylation analysis using the HM850K array. Irrespective of extraction technique or the use of fresh versus frozen urine samples, limited genomic DNA was obtained using a starting sample volume of 5ml (0-0.86μg/mL). In order to optimize the yield, we increased starting volumes to 50ml fresh urine, which yielded only 0-9.66μg/mL A different kit, QIAamp DNA Micro Kit, was trialled in six fresh urine samples and ten frozen urine samples with inadequate DNA yields from 0-17.7μg/mL and 0-1.6μg/mL respectively. Sufficient genomic DNA was obtained from only 4 of the initial 41 frozen urine samples (10%) for DNA methylation profiling. In comparison, all four buffy coat samples (100%) provided sufficient genomic DNA. High quality data can be obtained provided a sufficient yield of genomic DNA is isolated. Despite optimizing various extraction methodologies, the modest amount of genomic DNA derived from urine, may limit the generalisability of this approach for the identification of DNA methylation biomarkers of chronic diabetic kidney disease.

  4. Trace Chemical Analysis Methodology

    DTIC Science & Technology

    1980-04-01

    oxidation of nitrite-containing species. Calibration studies were then made in preparation for the analysis of unknown samples of nitrate in urine and...the procedure for nitrate determination was made on two types of samples : human urine , and drinking water from a city water supply. Five samples of...AND URINE Concentration Standard Sample type of NO3, ppm deviation Drinking water 1.29 ±0 04 1.20 ±0.09 1.29 ±0.14 1.15 ±0.08 0.88 ±0.07 Human urine

  5. The microbiome in PTEN hamartoma tumor syndrome.

    PubMed

    Byrd, Victoria; Getz, Ted; Padmanabhan, Roshan; Arora, Hans; Eng, Charis

    2018-03-01

    Germline PTEN mutations defining PTEN hamartoma tumor syndrome (PHTS) confer heritable predisposition to breast, endometrial, thyroid and other cancers with known age-related risks, but it remains impossible to predict if any individual will develop cancer. In the general population, gut microbial dysbiosis has been linked to cancer, yet is unclear whether these are associated in PHTS patients. In this pilot study, we aimed to characterize microbial composition of stool, urine, and oral wash from 32 PTEN mutation-positive individuals using 16S rRNA gene sequencing. PCoA revealed clustering of the fecal microbiome by cancer history ( P  = 0.03, R 2  = 0.04). Fecal samples from PHTS cancer patients had relatively more abundant operational taxonomic units (OTUs) from family Rikenellaceae and unclassified members of Clostridia compared to those from non-cancer patients, whereas families Peptostreptococcaceae, Enterobacteriaceae, and Bifidobacteriaceae represented relatively more abundant OTUs among fecal samples from PHTS non-cancer patients. Functional metagenomic prediction revealed enrichment of the folate biosynthesis, genetic information processing and cell growth and death pathways among fecal samples from PHTS cancer patients compared to non-cancer patients. We found no major shifts in overall diversity and no clustering by cancer history among oral wash or urine samples. Our observations suggest the utility of an expanded study to interrogate gut dysbiosis as a potential cancer risk modifier in PHTS patients. © 2018 The authors.

  6. Effects of processing delay, temperature, and transport tube type on results of quantitative bacterial culture of canine urine.

    PubMed

    Patterson, Carly A; Bishop, Micah A; Pack, Julie D; Cook, Audrey K; Lawhon, Sara D

    2016-01-15

    To determine the impact of processing delay, temperature, and transport tube type on results of quantitative bacterial culture (QBC) of canine urine. Diagnostic test evaluation. 60 mL of pooled urine from 4 dogs, divided into six 10-mL aliquots. Urine aliquots were spiked with bacteria from 1 of 6 independent Escherichia coli cultures to achieve a target bacterial concentration of 10(5) CFUs/mL. One milliliter from each aliquot was transferred into 5 silicone-coated clot tubes (SCTs) and 5 urine transport tubes (UTTs). Samples were stored at 4°C (39°F) and 25°C (77°F) for 0, 8, and 24 hours, and then standard QBCs were performed. Median bacterial concentration for urine samples stored in a UTT for 24 hours at 4°C was lower than that for samples stored in an SCT under the same conditions. Conversely, a substantial decrease in median bacterial concentration was identified for samples stored for 24 hours in an SCT at 25°C, compared with the median concentration for samples stored in a UTT under the same conditions. Median bacterial concentration in samples stored in an SCT at 25°C for 24 hours (275 CFUs/mL) was less than the cutoff typically used to define clinically important bacteriuria by use of urine samples obtained via cystocentesis (ie, > 1,000 CFUs/mL). Canine urine samples submitted for immediate QBC should be transported in plain sterile tubes such as SCTs. When prolonged (24-hour) storage at room temperature is anticipated, urine samples should be transported in UTTs.

  7. Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection.

    PubMed

    García-Coca, Marta; Gadea, Ignacio; Esteban, Jaime

    2017-06-01

    Urine culture is the gold standard for the diagnosis of urinary tract infections (UTI). The use of flow cytometry analyzers (FCA) prior to culture allows for the quantification and recognition of cell components in urine to be automated and makes it possible to relate these data to the urine pathogens subsequently identified in cultures. Urine samples were assessed with the Sysmex UF-1000i analyzer. Those that met the criteria for culture (> 25 leukocytes/μL or > 385 bacteria/μL) were subjected to quantitative urine culture on chromogenic agar. Counts of red blood cells (RBC), white blood cells (WBC), epithelial cells (EC), and the kind of microorganisms identified in cultures were evaluated. A total of 17,483 samples were processed by FCA. Of these, 9057 met the criteria for culture. Urine cultures were reduced by 48.2%. The most common urine pathogen was Escherichia coli (60.3%). Negative urine cultures were significantly (p < 0.001) associated with a lower WBC count than urine with E. coli, Klebsiella spp. and Proteus spp., but urine with Enterococcus spp. had a lower WBC than negative urine. Contaminated urine had a significantly (p < 0.001) lower WBC than urine with E. coli, Klebsiella spp. and Proteus spp., but no differences were found for Enterococcus spp. (p = 0.729). Negative urine cultures had significantly (p < 0.05) higher EC than all positive urine samples. Contaminated urine was associated (p < 0.001) with higher EC than cultures with E. coli and Klebsiella spp., in comparison with cultures with Enterococcus spp. (p = 0.091) and Proteus spp. (p = 0.251). The use of the Sysmex UF-1000i flow cytometer for screening urine samples allows for a reduction in the number of urine cultures. WBC values correlate well with the main urine pathogens related to UTI. The results observed for Enterococcus spp. suggest a low impact of these pathogens as a cause of UTI.

  8. Assessment of transpulmonary absorption of ethanol from alcohol-based hand rub.

    PubMed

    Hautemanière, Alexis; Ahmed-Lecheheb, Djihane; Cunat, Lisiane; Hartemann, Philippe

    2013-03-01

    Alcohol-based hand rubs (ABHRs) have been associated with a reduction of nosocomial infections. Despite the worldwide introduction of these products in health care settings, the aim of this study was to assess the transpulmonary absorption of ethanol contains in ABHRs used by health care workers (HCWs) in real conditions of work shift. Twenty-six HCWs of Nancy University Hospital were included. Research consisted in monitoring participants during 4 hours of work shift to assess their exposure to ethanol. The measurement of ethanol vapors in exhaled breath was performed using a class B ethylometer (Alco-Sensor FST). Ethanol concentration in inhaled breath was measured using Gilian pump LFS-113. Concentration of ethanol, acetaldehyde, and acetate in blood and urine samples were determined using gas chromatography with flame ionization detector. Participants were 12% male and 88% female. The mean age was 40 ± 8 years. None of the employees included in the study presented any traces of ethanol or its metabolites in the blood or urine. Ethanol (0.08 ± 0.07 mg/L) was detected in the breath of 10 HCWs at 1 to 2 minutes postexposure. The mean concentration of ethanol in the inhaled air was 46.2 mg/m. Absorption of ethanol vapor from ABHRs among HCWs during their care activities was not detected. Quantification of ethanol fumes inhaled during 4 hours of work shift was below the regulatory limitations of exposure to ethanol. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  9. Optimization of analytical and pre-analytical conditions for MALDI-TOF-MS human urine protein profiles.

    PubMed

    Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C

    2010-03-11

    Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.

  10. Absence of bacterial DNA in culture-negative urine from cats with and without lower urinary tract disease.

    PubMed

    Lund, Heidi Sjetne; Skogtun, Gaute; Sørum, Henning; Eggertsdóttir, Anna Vigdís

    2015-10-01

    A diagnosis of bacterial cystitis commonly relies on a positive microbiological culture demonstrating the presence of a significant number of colony-forming units/ml urine, as urine within the upper urinary tract, bladder and proximal urethra generally is considered sterile. Recent studies from human and veterinary medicine indicate the presence of non-culturable bacteria in culture-negative urine samples. The aim of the present study was to determine the occurrence of bacterial DNA in culture-negative urine samples from cats with signs of feline lower urinary tract disease (FLUTD) and healthy control cats by 16S ribosomal DNA PCR and subsequent sequencing. The study sample included 38 culture-negative urine samples from cats with FLUTD and 43 culture-negative samples from control cats. Eight culture-positive urine samples from cats with FLUTD were included as external positive controls in addition to negative reaction controls. Of possible methodological limitations, degradation of DNA due to storage, the use of non-sedimented urine for DNA isolation and lack of internal positive reaction controls should be mentioned. The positive controls were recognised, but occurrence of bacterial DNA in culture-negative urine from cats with or without signs of lower urinary tract disease was not demonstrated. However, considering the possible methodological limitations, the presence of bacterial DNA in the urine of culture-negative FLUTD cats cannot be excluded based on the present results alone. Therefore, a prospective study reducing the possibility of degradation of DNA due to storage, in combination with modifications enhancing the chance of detecting even lower levels of bacterial DNA in culture-negative samples, seems warranted. © ISFM and AAFP 2014.

  11. The Effects of Instrumentation on Urine Cytology and CK-20 Analysis for the Detection of Bladder Cancer.

    PubMed

    Wegelin, Olivier; Bartels, Diny W M; Tromp, Ellen; Kuypers, Karel C; van Melick, Harm H E

    2015-10-01

    To evaluate the effects of cystoscopy on urine cytology and additional cytokeratin-20 (CK-20) staining in patients presenting with gross hematuria. For 83 patients presenting with gross hematuria, spontaneous and instrumented paired urine samples were analyzed. Three patients were excluded. Spontaneous samples were collected within 1 hour before cystoscopy, and the instrumented samples were tapped through the cystoscope. Subsequently, patients underwent cystoscopic evaluation and imaging of the urinary tract. If tumor suspicious lesions were found on cystoscopy or imaging, subjects underwent transurethral resection or ureterorenoscopy. Two blinded uropathological reviewers (DB, KK) evaluated 160 urine samples. Reference standards were results of cystoscopy, imaging, or histopathology. Thirty-seven patients (46.3%) underwent transurethral resection or ureterorenoscopy procedures. In 30 patients (37.5%) tumor presence was confirmed by histopathology. The specificity of urine analysis was significantly higher for spontaneous samples than instrumented samples for both cytology alone (94% vs 72%, P = .01) and for cytology combined with CK-20 analysis (98% vs 84%, P = .02). The difference in sensitivity between spontaneous and instrumented samples was not significant for both cytology alone (40% vs 53%) and combined with CK-20 analysis (67% vs 67%). The addition of CK-20 analysis to cytology significantly increases test sensitivity in spontaneous urine cytology (67% vs 40%, P = .03). Instrumentation significantly decreases specificity of urine cytology. This may lead to unnecessary diagnostic procedures. Additional CK-20 staining in spontaneous urine cytology significantly increases sensitivity but did not improve the already high specificity. We suggest performing urine cytology and CK-20 analysis on spontaneously voided urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Ex vivo spontaneous generation of 19-norandrostenedione and nandrolone detected in equine plasma and urine.

    PubMed

    Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue

    2012-01-01

    19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (<407 pg/mL) was far lower (<0.4%) than that in the same samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in plasma of stallions and most of them detected in the urine have been shown to be spontaneously generated in vitro during sample storage. This finding would have significant implications with regard to the regulation of the two steroids in horse racing. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Urinary biomarkers of occupational jet fuel exposure among Air Force personnel.

    PubMed

    Smith, Kristen W; Proctor, Susan P; Ozonoff, A L; McClean, Michael D

    2012-01-01

    There is a potential for widespread occupational exposure to jet fuel among military and civilian personnel. Urinary metabolites of naphthalene have been suggested for use as short-term biomarkers of exposure to jet fuel (jet propulsion fuel 8 (JP8)). In this study, urinary biomarkers of JP8 were evaluated among US Air Force personnel. Personnel (n=24) were divided a priori into high, moderate, and low exposure groups. Pre- and post-shift urine samples were collected from each worker over three workdays and analyzed for metabolites of naphthalene (1- and 2-naphthol). Questionnaires and breathing-zone naphthalene samples were collected from each worker during the same workdays. Linear mixed-effects models were used to evaluate the exposure data. Post-shift levels of 1- and 2-naphthol varied significantly by a priori exposure group (levels in high group>moderate group>low group), and breathing-zone naphthalene was a significant predictor of post-shift levels of 1- and 2-naphthol, indicating that for every unit increase in breathing-zone naphthalene, there was an increase in naphthol levels. These results indicate that post-shift levels of urinary 1- and 2-naphthol reflect JP8 exposure during the work-shift and may be useful surrogates of JP8 exposure. Among the high exposed workers, significant job-related predictors of post-shift levels of 1- and 2-naphthol included entering the fuel tank, repairing leaks, direct skin contact with JP8, and not wearing gloves during the work-shift. The job-related predictors of 1- and 2-naphthol emphasize the importance of reducing inhalation and dermal exposure through the use of personal protective equipment while working in an environment with JP8.

  14. Calcium - urine

    MedlinePlus

    Urinary Ca+2; Kidney stones - calcium in urine; Renal calculi - calcium in your urine; Parathyroid - calcium in urine ... A 24-hour urine sample is most often needed: On day 1, urinate into the toilet when you wake up in the morning. ...

  15. Evaluation of Equations for Predicting 24-Hour Urinary Sodium Excretion from Casual Urine Samples in Asian Adults.

    PubMed

    Whitton, Clare; Gay, Gibson Ming Wei; Lim, Raymond Boon Tar; Tan, Linda Wei Lin; Lim, Wei-Yen; van Dam, Rob M

    2016-08-01

    The collection of 24-h urine samples for the estimation of sodium intake is burdensome, and the utility of spot urine samples in Southeast Asian populations is unclear. We aimed to assess the validity of prediction equations with the use of spot urine concentrations. A sample of 144 Singapore residents of Chinese, Malay, and Indian ethnicity aged 18-79 y were recruited from the Singapore Health 2 Study conducted in 2014. Participants collected urine for 24 h in multiple small bottles on a single day. To determine the optimal collection time for a spot urine sample, a 1-mL sample was taken from a random bottle collected in the morning, afternoon, and evening. Published equations and a newly derived equation were used to predict 24-h sodium excretion from spot urine samples. The mean ± SD concentration of sodium from the 24-h urine sample was 125 ± 53.4 mmol/d, which is equivalent to 7.2 ± 3.1 g salt. Bland-Altman plots showed good agreement at the group level between estimated and actual 24-h sodium excretion, with biases for the morning period of -3.5 mmol (95% CI: -14.8, 7.8 mmol; new equation) and 1.46 mmol (95% CI: -10.0, 13.0 mmol; Intersalt equation). A larger bias of 25.7 mmol (95% CI: 12.2, 39.3 mmol) was observed for the Tanaka equation in the morning period. The prediction accuracy did not differ significantly for spot urine samples collected at different times of the day or at a random time of day (P = 0.11-0.76). This study suggests that the application of both our own newly derived equation and the Intersalt equation to spot urine concentrations may be useful in predicting group means for 24-h sodium excretion in urban Asian populations. © 2016 American Society for Nutrition.

  16. Urinary casts

    MedlinePlus

    ... tubular epithelial casts; Waxy casts; Casts in the urine; Fatty casts; Red blood cell casts; White blood ... The urine sample you provide may need to be from your first morning urine. The sample needs to be ...

  17. Urine Cytology

    MedlinePlus

    ... types of cells were found in your urine sample. You may need to repeat the test. Negative. This means no cancer cells were identified in your urine sample. Atypical. This indicates that some abnormalities were found ...

  18. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.

    PubMed

    Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-10-07

    Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to -40°C or -80°C for 6 months before analysis also seem suitable. Copyright © 2016 by the American Society of Nephrology.

  19. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio

    PubMed Central

    Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-01-01

    Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are suitable for the measurement of urine albumin-to-creatinine ratio in randomized trials. Preserved samples frozen to −40°C or −80°C for 6 months before analysis also seem suitable. PMID:27654930

  20. The Urine Preservative Acetic Acid Degrades Urine Protein: Implications for Urine Biorepositories and the AASK Cohort Study

    PubMed Central

    Almaani, Salem; Hebert, Lee A.; Rovin, Brad H.

    2017-01-01

    Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β-2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid–mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. PMID:28104821

  1. The Urine Preservative Acetic Acid Degrades Urine Protein: Implications for Urine Biorepositories and the AASK Cohort Study.

    PubMed

    Almaani, Salem; Hebert, Lee A; Rovin, Brad H; Birmingham, Daniel J

    2017-05-01

    Patients enrolled in the African American Study of Kidney Disease and Hypertension (AASK) Cohort Study who exhibited overt proteinuria have been reported to show high nonalbumin proteinuria (NAP), which is characteristic of a tubulopathy. To determine whether African American Study of Kidney Disease and Hypertension nephropathy (AASK-N) is a tubulopathy, we obtained urine samples of 37 patients with AASK-N, with 24-hour protein-to-creatinine ratios (milligrams per milligram) ranging from 0.2 to 1.0, from the National Institute of Diabetes and Digestive Kidney Diseases repository and tested for seven markers of tubular proteinuria. By protocol, each sample had been collected in acetic acid (0.5%; mean final concentration). Compared with samples from patients with lupus nephritis or healthy black controls, AASK-N samples had lower amounts of six markers. Four markers (albumin, β -2-microglobulin, cystatin C, and osteopontin) were undetectable in most AASK-N samples. Examination by SDS-PAGE followed by protein staining revealed protein profiles indicative of severe protein degradation in 34 of 37 AASK-N urine samples. Treatment of lupus nephritis urine samples with 0.5% acetic acid produced the same protein degradation profile as that of AASK-N urine. We conclude that the increased NAP in AASK-N is an artifact of acetic acid-mediated degradation of albumin. The AASK-N repository urine samples have been compromised by the acetic acid preservative. Copyright © 2017 by the American Society of Nephrology.

  2. Length of time domestic dogs (Canis familiaris) spend smelling urine of gonadectomised and intact conspecifics.

    PubMed

    Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D

    2017-09-01

    Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted. ©2015 Wiley Periodicals, Inc.

  4. Protein urine test

    MedlinePlus

    Urine protein; Albumin - urine; Urine albumin; Proteinuria; Albuminuria ... After you provide a urine sample, it is tested. The health care provider uses a dipstick made with a color-sensitive pad. The color change ...

  5. Detection of Circulating Paracoccidioides brasiliensis Antigen in Urine of Paracoccidioidomycosis Patients before and during Treatment

    PubMed Central

    Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares

    1998-01-01

    For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407

  6. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode.

    PubMed

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.

  7. Collection and storage of urine specimens for measurement of urolithiasis risk factors.

    PubMed

    Wu, Wenqi; Yang, Dong; Tiselius, Hans-Goran; Ou, Lili; Mai, Zanlin; Chen, Kang; Zhu, Hanliang; Xu, Shaohong; Zhao, Zhijian; Zeng, Guohua

    2015-02-01

    To evaluate how different methods for storage and preservation of urine samples affected the outcome of analysis of risk factors for stone formation. Spot urine samples were collected from 21 healthy volunteers. Each fresh urine sample was divided into ten 10-mL aliquots: 2 without preservative, 2 with thymol, 2 with toluene, 2 with hydrochloric acid (HCl), and 2 with sodium azide. One sample of each pair was stored at 4 °C and the other at room temperature. The concentrations of calcium, magnesium, sodium, phosphate, urate, oxalate, citrate, and pH in each urine sample were analyzed immediately after collection (0 hour) and after 24 and 48 hours. There were no significant differences in calcium, oxalate, magnesium, phosphate, sodium, urate or pH (without acidification) between samples with different preservation methods (P >.05). Urinary citrate, however, was significantly lower in the urine collected with HCl than when other preservatives were used, both at room temperature and at 4 °C. Urine pH was significantly higher after 48 hours than after 24 hours, whether the samples were stored at room temperature or at 4 °C. Antibacterial preservatives (eg, thymol or toluene) can be recommended as preservatives for 24-hour urine collections. Ideally, the samples should be stored at 4 °C. When HCl is used as a preservative, it seems essential to neutralize the samples before analysis. This is particularly obvious with the chromatographic method used for analysis of citrate that was used in this study. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Detection and genotyping of HPV in urine samples from Chilean women attending primary health care centers.

    PubMed

    Vergara, Nicolás; Balanda, Monserrat; Hidalgo, Wilma; Martín, Héctor San; Aceituno, Alexis; Roldán, Francisco; Villalón, Tania; Hott, Melissa; Espinoza, Gloria; Quiero, Andrea; Valenzuela, María T; Ramírez, Eugenio

    2018-04-01

    Cervical cancer is the second most common malignant neoplasm in women worldwide representing approximately 10% of all types of cancers. Triage of women through cervical cytology has been an important strategy for the surveillance and control of new cases of cervical cancer. However, in many regions around the world cervical cytology has a low coverage compared to developed countries. The molecular detection of HPV is the most effective method to increase the screening sensitivity of women at risk of developing cervical cancer. There are very few studies about the efficacy of urine testing for detection of HPV in women followed up in primary health care centers. Consequently, the efficacy of using urine HPV screening in these populations has not been addressed yet. Here, we compared the detection of HPV in simultaneous urine and cervical samples of women followed up in primary health care centers. Urine and cervical samples were analyzed in 543 women attending at primary health care centers. HPV was detected by real time PCR, and HPV typing performed by PCR-RLB. A general HPV concordance of 86.2% (κ = 0.72) was determined between urine and cervical samples. The concordance for HPV-16 and 18 was almost perfect (κ = 0.82) and strong (κ = 0.77), respectively. The sensitivity and specificity for all HPV genotypes in urine using cervical samples as reference were 82.1 and 93.7%, respectively. The results showed that urine is a good alternative as clinical sample for HPV screening in women attending primary health care centers. Therefore, urine should be used as an alternative sample for increasing triage coverage either in refractory women participating in Pap surveillance programs or when cervical samples are not available.

  9. Effect of a commercial anion dietary supplement on acid-base balance, urine volume, and urinary ion excretion in male goats fed oat or grass hay diets.

    PubMed

    Stratton-Phelps, Meri; House, John K

    2004-10-01

    To determine whether feeding a commercial anionic dietary supplement as a urinary acidifier to male goats may be useful for management of urolithiasis. 8 adult sexually intact male Toggenburg, Saanen, and Nubian goats. Goats were randomly assigned by age-, breed-, and weight-matched pairs to an oat or grass hay diet that was fed for 12 days. On days 13 to 14 (early sample collection time before supplementation), measurements were made of blood and urine sodium, potassium, calcium, magnesium, chloride, phosphorus, and sulfur concentrations; blood and urine pH; urine production; and water consumption. During the next 28 days, the anionic dietary supplement was added to the oat and grass hay diets to achieve a dietary cation-anion difference of 0 mEq/100g of dry matter. Blood and urine samples were analyzed during dietary supplementation on days 12 to 13 (middle sample collection time) and 27 to 28 (late sample collection time). Blood bicarbonate, pH, and urine pH of goats fed grass hay and goats fed oat hay were significantly decreased during the middle and late sample collection times, compared with the early sample collection time. Water consumption and urine production in all goats increased significantly during the late sample collection time, compared with the early sample collection time. The anionic dietary supplement used in our study increases urine volume, alters urine ion concentrations, and is an efficacious urinary acidifier in goats. Goats treated with prolonged anionic dietary supplementation should be monitored for secondary osteoporosis from chronic urinary calcium loss.

  10. Sample preparation and storage can change arsenic speciation in human urine.

    PubMed

    Feldmann, J; Lai, V W; Cullen, W R; Ma, M; Lu, X; Le, X C

    1999-11-01

    Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine, in human urine. We compared the effects of the following storage conditions on the stability of these arsenic species: temperature (25, 4, and -20 degrees C), storage time (1, 2, 4, and 8 months), and the use of additives (HCl, sodium azide, benzoic acid, benzyltrimethylammonium chloride, and cetylpyridinium chloride). HPLC with both inductively coupled plasma mass spectrometry and hydride generation atomic fluorescence detection techniques were used for the speciation of arsenic. We found that all five of the arsenic species were stable for up to 2 months when urine samples were stored at 4 and -20 degrees C without any additives. For longer period of storage (4 and 8 months), the stability of arsenic species was dependent on urine matrices. Whereas the arsenic speciation in some urine samples was stable for the entire 8 months at both 4 and -20 degrees C, other urine samples stored under identical conditions showed substantial changes in the concentration of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid. The use of additives did not improve the stability of arsenic speciation in urine. The addition of 0.1 mol/L HCl (final concentration) to urine samples produced relative changes in inorganic As(III) and As(V) concentrations. Low temperature (4 and -20 degrees C) conditions are suitable for the storage of urine samples for up to 2 months. Untreated samples maintain their concentration of arsenic species, and additives have no particular benefit. Strong acidification is not appropriate for speciation analysis.

  11. NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...

  12. Urine sampling and collection system

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.

    1971-01-01

    This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

  13. Filter paper saturated by urine sample in metabolic disorders detection by proton magnetic resonance spectroscopy.

    PubMed

    Blasco, Hélène; Garrigue, Marie-Ange; De Vos, Aymeric; Antar, Catherine; Labarthe, François; Maillot, François; Andres, Christian R; Nadal-Desbarats, Lydie

    2010-02-01

    NMR spectroscopy of urine samples is able to diagnose many inborn errors of metabolism (IEM). However, urinary metabolites have a poor stability, requiring special care for routine analysis (storage of urine at -20 or -80 degrees C, fast transport). The aim of our study was to investigate the reliability of dried urine filter paper for urine storage and transport and to evaluate the ability of NMR to detect several IEM using this method. Urine samples from five healthy subjects were analyzed by (1)H NMR following different storage conditions (-20 vs 4 degrees C vs dried on filter paper) and at different time points (24 h, 48 h, 96 h, and 7 days). Urine pattern of fresh urine was considered as a reference. We analyzed the conservation of some amino acids and organic acids using Bland and Altman plot with intraclass correlation coefficient determination. Then, we evaluated the use of filter paper to detect four different IEM (methylmalonic and isovaleric acidurias, ornithine transcarbamylase deficiency, and cystinuria). Analysis of urine samples from healthy subjects revealed a high stability of studied molecules (ICC > 0.8) even after 7 days of storage on filter paper. Moreover, an excellent preservation of metabolites specifically accumulated in IEM was observed when analysis of dried urine filter paper was compared to fresh urine (coefficient of variation < 15%). This preliminary study demonstrates that storage of dried urine on filter paper is reliable for (1)H NMR spectroscopy analysis. Preservation of urine molecules over time using that method is convenient for routine clinical practice.

  14. Measurements of C-reactive protein (CRP) and nerve-growth-factor (NGF) concentrations in serum and urine samples of dogs with neurologic disorders.

    PubMed

    Kordass, Ulrike; Carlson, Regina; Stein, Veronika Maria; Tipold, Andrea

    2016-01-08

    The purpose of this study was to prove the hypothesis that C-reactive protein (CRP) and nerve growth factor (NGF) may be potential biomarkers for lower urinary tract disorders and may be able to distinguish between micturition dysfunctions of different origin in dogs with spinal cord diseases. NGF- and CRP- concentrations were measured in serum and urine samples using specific ELISA-Kits. Results in urine were standardized by urine-creatinine levels. CRP in serum was detectable in 32/76 and in urine samples in 40/76 patients. NGF could be measured in all serum and in 70/76 urine samples. Urinary CRP concentrations were significantly higher in dogs with micturition dysfunction (p = 0.0009) and in dogs with different neurological diseases (p = 0.0020) compared to the control group. However, comparing dogs with spinal cord disorders with and without associated micturition dysfunction no significant difference could be detected for NGF and CRP values in urine or serum samples. Additionally, levels did not decrease significantly, when measured at the time when the dogs regained the ability to urinate properly (urinary NGF p = 0.7962; urinary CRP p = 0.078). Urine samples with bacteria and/or leukocytes had no significant increase in urinary NGF (p = 0.1112) or CRP (p = 0.0534) concentrations, but higher CRP-levels in urine from dogs with cystitis were found compared to dogs without signs of cystitis. From these data we conclude that neither CRP nor NGF in urine or serum can be considered as reliable biomarkers for micturition disorders in dogs with spinal cord disorders in a clinical setting, but their production might be part of the pathogenesis of such disorders. Significantly higher levels of CRP could be found in the urine of dogs with micturition dysfunctions compared to control dogs. This phenomenon could potentially be explained by unspecific extrahepatic CRP production by smooth muscle cells in the dilated bladder.

  15. Prevalence of caffeine use in elite athletes following its removal from the World Anti-Doping Agency list of banned substances.

    PubMed

    Del Coso, Juan; Muñoz, Gloria; Muñoz-Guerra, Jesús

    2011-08-01

    The aim of this investigation was to determine the use of caffeine by athletes after its removal from the World Anti-Doping Agency list. For this purpose, we measured the caffeine concentration in 20 686 urine samples obtained for doping control from 2004 to 2008. We utilized only urine samples obtained after official national and international competitions. Urine caffeine concentration was determined using alkaline extraction followed by gas chromatography-mass spectrometry. The limit of detection (LOD) was set at 0.1 µg·mL(-1). The percentage of urine samples below the LOD was 26.2%; the remaining 73.8% of the urine samples contained caffeine. Most urine samples (67.3%) had urinary caffeine concentrations below 5 µg·mL(-1). Only 0.6% of urine samples exceeded the former threshold for caffeine doping (12 µg·mL(-1)). Triathlon (3.3 ± 2.2 µg·mL(-1)), cycling (2.6 ± 2.0 µg·mL(-1)), and rowing (1.9 ± 1.4 µg·mL(-1)) were the sports with the highest levels of urine caffeine concentration; gymnastics was the sport with the lowest urine caffeine concentration (0.5 ± 0.4 µg·mL(-1)). Older competitors (>30 y) had higher levels of caffeine in their urine than younger competitors (<20 y; p < 0.05); there were no differences between males and females. In conclusion, 3 out of 4 athletes had consumed caffeine before or during sports competition. Nevertheless, only a small proportion of these competitors (0.6%) had a urine caffeine concentration higher than 12 µg·mL(-1). Endurance sports were the disciplines showing the highest urine caffeine excretion after competition.

  16. Comparison of urine specimen collection times and testing fractions for the detection of high-risk human papillomavirus and high-grade cervical precancer.

    PubMed

    Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S

    2016-01-01

    Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Night shift work and other determinants of estradiol, testosterone, and dehydroepiandrosterone sulfate among middle-aged nurses and midwives.

    PubMed

    Peplonska, Beata; Bukowska, Agnieszka; Lie, Jenny Anne; Gromadzinska, Jolanta; Zienolddiny, Shanbeh

    2016-09-01

    The aims of our study were to (i) investigate the association between rotating night shift work and blood concentrations of estradiol, testosterone and dehydroepiandrosterone sulfate (DHEAS) and (2) evaluate the role of their non-occupational determinants. A cross-sectional study was conducted on 345 premenopausal and 187 postmenopausal nurses and midwives (263 women working rotating night shifts and 269 women working during days). Data from in-person interviews were used, anthropometric measurements were performed, and body mass index (BMI) and waist- to-hip ratio were calculated. Morning blood and spot urine samples were collected. Multiple linear regression models were fitted with hormone concentrations as dependent variables, and night shift work characteristics and demographic, reproductive, lifestyle and anthropometric determinants as independent variables. Modification of the effect by chronotype was examined. Among postmenopausal women, we observed a statistically significant positive association between the total duration of night shift work >15 years and estradiol level (P<0.05 when compared to night work duration <5 years). Night shift work characteristics were significantly associated with estradiol among morning-type postmenopausal women. The well-established associations between hormones and their major determinants, such as age and BMI, were confirmed. The findings of our study imply that prolonged night shift work may be associated with increased estradiol levels among postmenopausal women, especially among the morning-type postmenopausal women.

  18. Alterations of microbiota in urine from women with interstitial cystitis

    PubMed Central

    2012-01-01

    Background Interstitial Cystitis (IC) is a chronic inflammatory condition of the bladder with unknown etiology. The aim of this study was to characterize the microbial community present in the urine from IC female patients by 454 high throughput sequencing of the 16S variable regions V1V2 and V6. The taxonomical composition, richness and diversity of the IC microbiota were determined and compared to the microbial profile of asymptomatic healthy female (HF) urine. Results The composition and distribution of bacterial sequences differed between the urine microbiota of IC patients and HFs. Reduced sequence richness and diversity were found in IC patient urine, and a significant difference in the community structure of IC urine in relation to HF urine was observed. More than 90% of the IC sequence reads were identified as belonging to the bacterial genus Lactobacillus, a marked increase compared to 60% in HF urine. Conclusion The 16S rDNA sequence data demonstrates a shift in the composition of the bacterial community in IC urine. The reduced microbial diversity and richness is accompanied by a higher abundance of the bacterial genus Lactobacillus, compared to HF urine. This study demonstrates that high throughput sequencing analysis of urine microbiota in IC patients is a powerful tool towards a better understanding of this enigmatic disease. PMID:22974186

  19. Negligible heat strain in armored vehicle officers wearing personal body armor

    PubMed Central

    2011-01-01

    Objectives This study evaluated the heat strain experienced by armored vehicle officers (AVOs) wearing personal body armor (PBA) in a sub-tropical climate. Methods Twelve male AVOs, aged 35-58 years, undertook an eight hour shift while wearing PBA. Heart rate and core temperature were monitored continuously. Urine specific gravity (USG) was measured before and after, and with any urination during the shift. Results Heart rate indicated an intermittent and low-intensity nature of the work. USG revealed six AVOs were dehydrated from pre through post shift, and two others became dehydrated. Core temperature averaged 37.4 ± 0.3°C, with maximum's of 37.7 ± 0.2°C. Conclusions Despite increased age, body mass, and poor hydration practices, and Wet-Bulb Globe Temperatures in excess of 30°C; the intermittent nature and low intensity of the work prevented excessive heat strain from developing. PMID:21801453

  20. Night shift work and hormone levels in women.

    PubMed

    Davis, Scott; Mirick, Dana K; Chen, Chu; Stanczyk, Frank Z

    2012-04-01

    Night shift work may disrupt the normal nocturnal rise in melatonin, resulting in increased breast cancer risk, possibly through increased reproductive hormone levels. We investigated whether night shift work is associated with decreased levels of urinary 6-sulfatoxymelatonin, the primary metabolite of melatonin, and increased urinary reproductive hormone levels. Participants were 172 night shift and 151 day shift-working nurses, aged 20-49 years, with regular menstrual cycles. Urine samples were collected throughout work and sleep periods and assayed for 6-sulfatoxymelatonin, luteinizing hormone (LH), follicle-stimulating hormone (FSH), and estrone conjugate (E1C). 6-Sulfatoxymelatonin levels were 62% lower and FSH and LH were 62% and 58% higher, respectively, in night shift-working women during daytime sleep than in day shift-working women during nighttime sleep (P ≤ 0.0001). Nighttime sleep on off-nights was associated with 42% lower 6-sulfatoxymelatonin levels among the night shift workers, relative to the day shift workers (P < 0.0001); no significant differences in LH or FSH were observed. 6-Sulfatoxymelatonin levels during night work were approximately 69% lower and FSH and LH were 35% and 38% higher, compared with day shift workers during nighttime sleep. No differences in E1C levels between night and day shift workers were observed. Within night shift workers, 6-sulfatoxymelatonin levels were lower and reproductive hormone levels were higher during daytime sleep and nighttime work, relative to nighttime sleep (P < 0.05). These results indicate that night shift workers have substantially reduced 6-sulfatoxymelatonin levels during night work and daytime sleep and that levels remain low even when a night shift worker sleeps at night. Shift work could be an important risk factor for many other cancers in addition to breast cancer. ©2012 AACR.

  1. Ionic Liquid Dispersive Liquid-Liquid Microextraction Method for the Determination of Irinotecan, an Anticancer Drug, in Water and Urine Samples Using UV-Vis Spectrophotometry.

    PubMed

    Uysal, Deniz; Karadaş, Cennet; Kara, Derya

    2017-05-01

    A new, simple, efficient, and environmentally friendly ionic liquid dispersive liquid-liquid microextraction method was developed for the determination of irinotecan, an anticancer drug, in water and urine samples using UV-Vis spectrophotometry. The ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate was used as the extraction solvent, and ethanol was used as the disperser solvent. The main parameters affecting the extraction efficiency, including sample pH, volume of the ionic liquid, choice of the dispersive solvent and its volume, concentration of NaCl, and extraction and centrifugation times, were investigated and optimized. The effect of interfering species on the recovery of irinotecan was also examined. Under optimal conditions, the LOD (3σ) was 48.7 μg/L without any preconcentration. Because the urine sample was diluted 10-fold, the LOD for urine would be 487 μg/L. However, this could be improved 16-fold if preconcentration using a 40 mL aliquot of the sample is used. The proposed method was successfully applied to the determination of irinotecan in tap water, river water, and urine samples spiked with 10.20 mg/L for the water samples and 8.32 mg/L for the urine sample. The average recovery values of irinotecan determined were 99.1% for tap water, 109.4% for river water, and 96.1% for urine.

  2. Is a pre-analytical process for urinalysis required?

    PubMed

    Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole

    2017-10-01

    For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.

  3. Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.

    PubMed

    Holm, Anne; Aabenhus, Rune

    2016-06-08

    Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.

  4. [Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].

    PubMed

    Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo

    2016-03-01

    The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.

  5. Comparison of urine and bladder or urethral mucosal biopsy culture obtained by transurethral cystoscopy in dogs with chronic lower urinary tract disease: 41 cases (2002 to 2011).

    PubMed

    Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R

    2014-07-01

    To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.

  6. [Delayed testing for the diagnosis of fungi in the urines. Evaluation of the BD Vacutainer C&S tubes for the storage of urine samples at room temperature].

    PubMed

    Baixench, M T; Al-Sheikh, M; Paugam, A

    2005-01-01

    The study included 37 urine samples which have been artificially infected with low levels (10(3) CFU/mL) of various fungi strains. We compared the effects of sample storage, up to 48 hours, at room temperature, in a urine evacuated tube containing specific additives with storage at + 4 degrees C, for the same length of time, in a urine evacuated tube without any additives. There have been no differences of results (speed of growth and colony size) between the 2 modes of storage. However, the experience has shown that samples needed a careful mixing before seeding to avoid underdetection of the strains. Based on the study results, the BD Vacutainer C&S tubes are suitable for delayed testing for the diagnosis of urine fungal infection.

  7. Detection of human papillomavirus DNA in urine. A review of the literature.

    PubMed

    Vorsters, A; Micalessi, I; Bilcke, J; Ieven, M; Bogers, J; Van Damme, P

    2012-05-01

    The detection of human papillomavirus (HPV) DNA in urine, a specimen easily obtained by a non-invasive self-sampling method, has been the subject of a considerable number of studies. This review provides an overview of 41 published studies; assesses how different methods and settings may contribute to the sometimes contradictory outcomes; and discusses the potential relevance of using urine samples in vaccine trials, disease surveillance, epidemiological studies, and specific settings of cervical cancer screening. Urine sampling, storage conditions, sample preparation, DNA extraction, and DNA amplification may all have an important impact on HPV DNA detection and the form of viral DNA that is detected. Possible trends in HPV DNA prevalence in urine could be inferred from the presence of risk factors or the diagnosis of cervical lesions. HPV DNA detection in urine is feasible and may become a useful tool but necessitates further improvement and standardization.

  8. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    PubMed

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  9. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 7 metals in 86 urine samples over 86 households. Each sample was collected from the primary respondent within each household. The sample consists of the first morning void following the 24-hour d...

  10. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    PubMed

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  11. Effects of storage time and temperature on pH, specific gravity, and crystal formation in urine samples from dogs and cats.

    PubMed

    Albasan, Hasan; Lulich, Jody P; Osborne, Carl A; Lekcharoensuk, Chalermpol; Ulrich, Lisa K; Carpenter, Kathleen A

    2003-01-15

    To determine effects of storage temperature and time on pH and specific gravity of and number and size of crystals in urine samples from dogs and cats. Randomized complete block design. 31 dogs and 8 cats. Aliquots of each urine sample were analyzed within 60 minutes of collection or after storage at room or refrigeration temperatures (20 vs 6 degrees C [68 vs 43 degrees F]) for 6 or 24 hours. Crystals formed in samples from 11 of 39 (28%) animals. Calcium oxalate (CaOx) crystals formed in vitro in samples from 1 cat and 8 dogs. Magnesium ammonium phosphate (MAP) crystals formed in vitro in samples from 2 dogs. Compared with aliquots stored at room temperature, refrigeration increased the number and size of crystals that formed in vitro; however, the increase in number and size of MAP crystals in stored urine samples was not significant. Increased storage time and decreased storage temperature were associated with a significant increase in number of CaOx crystals formed. Greater numbers of crystals formed in urine aliquots stored for 24 hours than in aliquots stored for 6 hours. Storage time and temperature did not have a significant effect on pH or specific gravity. Urine samples should be analyzed within 60 minutes of collection to minimize temperature- and time-dependent effects on in vitro crystal formation. Presence of crystals observed in stored samples should be validated by reevaluation of fresh urine.

  12. Multiplexed Microsphere Suspension-Array Assay for Urine Mitochondrial DNA Typing by C-Stretch Length in Hypervariable Regions.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Kawahara, Takashi

    2018-07-01

    The standard method for personal identification and verification of urine samples in doping control is short tandem repeat (STR) analysis using nuclear DNA (nDNA). The DNA concentration of urine is very low and decreases under most conditions used for sample storage; therefore, the amount of DNA from cryopreserved urine samples may be insufficient for STR analysis. We aimed to establish a multiplexed assay for urine mitochondrial DNA typing containing only trace amounts of DNA, particularly for Japanese populations. A multiplexed suspension-array assay using oligo-tagged microspheres (Luminex MagPlex-TAG) was developed to measure C-stretch length in hypervariable region 1 (HV1) and 2 (HV2), five single nucleotide polymorphisms (SNPs), and one polymorphic indel. Based on these SNPs and the indel, the Japanese population can be classified into five major haplogroups (D4, B, M7a, A, D5). The assay was applied to DNA samples from urine cryopreserved for 1 - 1.5 years (n = 63) and fresh blood (n = 150). The assay with blood DNA enabled Japanese subjects to be categorized into 62 types, exhibiting a discriminatory power of 0.960. The detection limit for cryopreserved urine was 0.005 ng of nDNA. Profiling of blood and urine pairs revealed that 5 of 63 pairs showed different C-stretch patterns in HV1 or HV2. The assay described here yields valuable information in terms of the verification of urine sample sources employing only trace amounts of recovered DNA. However, blood cannot be used as a reference sample.

  13. Stability studies of amphetamine and ephedrine derivatives in urine.

    PubMed

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  14. Albumin adsorption onto surfaces of urine collection and analysis containers☆

    PubMed Central

    Robinson, Mary K.; Caudill, Samuel P.; Koch, David D.; Ritchie, James; Hortin, Glen; Eckfeldt, John H.; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W. Greg

    2017-01-01

    Background Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. Methods We added 125I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Results Adsorption of urine albumin (UA) at 5–6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH 8 than pH 5 but only 3 cases had p <0.05. Adsorption from 11 unaltered urine samples with albumin 5–333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2 l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2–28%) was larger than that from urine. Conclusions Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. PMID:24513540

  15. Albumin adsorption onto surfaces of urine collection and analysis containers.

    PubMed

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was <0.9%; and at 90 mg/l was <0.4%. Adsorption was generally less at pH8 than pH5 but only 3 cases had p<0.05. Adsorption from 11 unaltered urine samples with albumin 5-333 mg/l was <0.8%. Albumin adsorption for the material with greatest binding was extrapolated to the surface areas of 100 ml and 2l collection containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Solid phase extraction of 2,4-D from human urine.

    PubMed

    Thompson, T S; Treble, R G

    1996-10-01

    A method for determining urinary concentrations of 2,4-D in samples collected from non-occupationally, environmentally exposed individuals was developed. The 2,4-D was extracted from fortified human urine samples using octadecylsilane solid phase extraction cartridges. The average percent recovery for urine samples spiked at 2 and 20 ng/mL was 100% and 93%, respectively. The method detection limit was estimated to be 0.75 ng of 2,4-D per mL of urine based on a 10 mL sample size. The potential use of 2,4-dichlorophenylacetic acid as a surrogate standard was also investigated.

  17. Quantitative determination of BAF312, a S1P-R modulator, in human urine by LC-MS/MS: prevention and recovery of lost analyte due to container surface adsorption.

    PubMed

    Li, Wenkui; Luo, Suyi; Smith, Harold T; Tse, Francis L S

    2010-02-15

    Analyte loss due to non-specific binding, especially container surface adsorption, is not uncommon in the quantitative analysis of urine samples. In developing a sensitive LC-MS/MS method for the determination of a drug candidate, BAF312, in human urine, a simple procedure was outlined for identification, confirmation and prevention of analyte non-specific binding to a container surface and to recover the 'non-specific loss' of an analyte, if no transfer has occurred to the original urine samples. Non-specific binding or container surface adsorption can be quickly identified by using freshly spiked urine calibration standards and pre-pooled QC samples during a LC-MS/MS feasibility run. The resulting low recovery of an analyte in urine samples can be prevented through the use of additives, such as the non-ionic surfactant Tween-80, CHAPS and others, to the container prior to urine sample collection. If the urine samples have not been transferred from the bulk container, the 'non-specific binding' of an analyte to the container surface can be reversed by the addition of a specified amount of CHAPS, Tween-80 or bovine serum albumin, followed by appropriate mixing. Among the above agents, Tween-80 is the most cost-effective. beta-cyclodextrin may be suitable in stabilizing the analyte of interest in urine via pre-treating the matrix with the agent. However, post-addition of beta-cyclodextrin to untreated urine samples does not recover the 'lost' analyte due to non-specific binding or container surface adsorption. In the case of BAF312, a dynamic range of 0.0200-20.0 ng/ml in human urine was validated with an overall accuracy and precision for QC sample results ranging from -3.2 to 5.1% (bias) and 3.9 to 10.2% (CV), respectively. Pre- and post-addition of 0.5% (v/v) Tween-80 to the container provided excellent overall analyte recovery and minimal MS signal suppression when a liquid-liquid extraction in combination with an isocratic LC separation was employed. The compound was stable in 0.5% Tween-80 treated human urine QC samples for at least 24 h at room temperature, after three freeze/thaw cycles with storage at < or =-60 degrees C and for at least 3 months when stored at < or =-60 degrees C. The current work could serve as a simple example in trouble shooting non-specific binding or container surface adsorption in quantitative analysis of urine samples. Copyright 2010. Published by Elsevier B.V.

  18. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    PubMed

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Testing for nandrolone metabolites in urine samples of professional athletes and sedentary subjects by GC/MS/MS analysis.

    PubMed

    Gambelunghe, Cristiana; Sommavilla, Marco; Rossi, Ruggero

    2002-12-01

    The concentrations of nandrolone metabolites, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) were analysed in urine samples of professional athletes doing intense physical activity and sedentary subjects to verify if there was endogenous production of nandrolone and if there was any link between physical effort and the urinary metabolites of the steroid. We collected 18 urine samples from professional footballers age range 20-30 years, all from the same team, and 18 urine samples from males not doing any physical activity, age range 20-30 years. Neither group used nandrolone. Qualitative and quantitative analyses of urinary nandrolone metabolites were carried out by GC/MS followed by GC/MS/MS to confirm positive samples. This technique has been demonstrated to be an excellent analytical approach for the determination of anabolic steroids at very low detection limits in complex matrices such as urine. In five urine samples from professional footballers traces of 19-NA were detected. No trace of 19-NA was found in the group of sedentary subjects and no trace of 19-NE was found in any urine sample. The absence of nandrolone metabolites in sedentary subjects supports the hypothesis that the presence of 19-NA and 19-NE could be linked to physical effort even though the origin is not yet clear. Copyright 2002 John Wiley & Sons, Ltd.

  20. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  1. 51Cr-EDTA absorption blood test: an easy method for assessing small intestinal permeability in dogs.

    PubMed

    Frias, Rafael; Sankari, Satu; Westermarck, Elias

    2004-01-01

    The 51Cr-EDTA test is a valuable clinical tool for screening intestinal diseases in dogs. The test is performed by calculating the percentage of recovery from urine of a PO-ingested dose of 51Cr-EDTA after 6 or 24 hours. Careful urine collection is a practical limitation of this test in dogs, and our goal was to develop a simpler test that measures 51Cr-EDTA in blood. A 51Cr-EDTA absorption test was simultaneously performed on urine and serum 43 times in healthy Beagle Dogs. Timed blood samples were withdrawn, and urine was collected during a 6-hour period. Percentages of the ingested dose were then calculated in urine and serum. The mean +/- standard deviation (range) percentage in urine after 6 hours was 14.07 +/- 8.72% (3.81-34.18%), whereas results in serum from samples taken at 2, 3, 4, 5, and 6 hours were 0.49 +/- 0.45% (0.02-2.13%), 0.75 +/- 0.52% (0.03-1.89%), 0.82 +/- 0.57% (0.13-2.21%), 0.70 +/- 0.53% (0.12-1.99%), and 0.47 +/- 0.44% (0.11-1.79%), respectively. The results for blood specimens showed good concordance with those for urine, especially for the samples taken at 4 hours (r = 0.89). Moreover, the correlation between urine and blood was better when the sum of the percentages of the recovered analyte from various blood samples was compared with urine. The correlation coefficient when summing 4 blood samples was excellent (r = 0.97) and remained excellent when summing only 2 blood samples taken at 3 and 5 hours (r = 0.95) or at 3 and 4 hours (r = 0.94). We conclude that a serum 51Cr-EDTA test determined by summing successive blood samples provides an easier means of estimating small intestinal permeability in dogs and gives results comparable to those of the 6-hour urine test.

  2. The effect of diet enriched with rapeseed meal on endogenous thiouracil contents in urine and milk of cattle.

    PubMed

    Wozniak, Barbara; Matraszek-Zuchowska, Iwona; Witek, Sebastian; Zmudzki, Jan; Posyniak, Andrzej

    2018-01-15

    Thyreostatic compounds, such as thiouracil, are orally active drugs that can be used to increase the weight of cattle before slaughter. Due to potentially teratogenic and carcinogenic effects of their residues on public health, the use of thyreostats in animal production has been banned in the European Union since 1981. Systematic detection of low concentrations of thiouracil in the urine of livestock in many countries is believed to be of endogenous origin due to the use of Brassicaceae plants in the animal diet. Therefore, the purpose of the study was to determine the effects of diets rich in rapeseed meal on formation of thiouracil in urine and milk of dairy cows. For two weeks three cows were subjected to a diet supplemented with rapeseed at 30%, compared to the control cattle diet which contained up to 11% rapeseed. During the experiment, samples of urine and milk were collected and analysed by LC-MS/MS. The increase and decrease of thiouracil concentration in urine samples in different animals was individual and cyclic. The highest concentration of natural thiouracil determined in urine was 3.61 μg l -1 . It has been found that endogenous thiouracil exists in two tautomeric forms. A few days of storage of frozen urine samples affected the stability of natural thiouracil, whereas an acidic medium improved the stability of the compound and its isomer, which remained stable even after two months of storage at temperatures below -18°C. Due to the instability of thiouracil, urine samples upon sampling should be delivered to the laboratory as soon as possible or properly preserved. In milk samples, thiouracil was not found above the decision limit of the applied method of 0.63 μg l -1 . Preliminary studies have shown that faecal examination for banned thiouracil can be a complementary test for urine samples, and may be helpful in determining the origin of the compound present in urine.

  3. Space sickness predictors suggest fluid shift involvement and possible countermeasures

    NASA Technical Reports Server (NTRS)

    Simanonok, K. E.; Moseley, E. C.; Charles, J. B.

    1992-01-01

    Preflight data from 64 first time Shuttle crew members were examined retrospectively to predict space sickness severity (NONE, MILD, MODERATE, or SEVERE) by discriminant analysis. From 9 input variables relating to fluid, electrolyte, and cardiovascular status, 8 variables were chosen by discriminant analysis that correctly predicted space sickness severity with 59 pct. success by one method of cross validation on the original sample and 67 pct. by another method. The 8 variables in order of their importance for predicting space sickness severity are sitting systolic blood pressure, serum uric acid, calculated blood volume, serum phosphate, urine osmolality, environmental temperature at the launch site, red cell count, and serum chloride. These results suggest the presence of predisposing physiologic factors to space sickness that implicate a fluid shift etiology. Addition of a 10th input variable, hours spent in the Weightless Environment Training Facility (WETF), improved the prediction of space sickness severity to 66 pct. success by the first method of cross validation on the original sample and to 71 pct. by the second method. The data suggest that WETF training may reduce space sickness severity.

  4. Evaluation of commercial boric acid containing vials for urine culture: low risk of contamination and cost effectiveness considerations.

    PubMed

    Appannanavar, Suma B; Biswal, Manisha; Rajkumari, Nonika; Mohan, Balvinder; Taneja, Neelam

    2013-01-01

    Urine culture is a gold standard in the diagnosis of urinary tract infection. Clean catch midstream urine collection and prompt transportation is essential for appropriate diagnosis. Improper collection and delay in transportation leads to diagnostic dilemma. In developing countries, higher ambient temperatures further complicate the scenario. Here, we have evaluated the role of boric acid as a preservative for urine samples prior to culture in female patients attending outpatient department at our center. Consecutive 104 urine samples were cultured simultaneously in plain uricol (Control-C) and boric acid containing tubes from Becton Dickinson urine culture kit (Boric acid group-BA). In the real-time evaluation, we found that in almost 57% (59/104) of the urine samples tested, it was more effective in maintaining the number of the organisms as compared to samples in the container without any preservative. Our in vitro study of simulated urine cultures revealed that urine samples could be kept up to 12 h before culture in the preservative without any inhibitory effect of boric acid. Though the use of boric acid kit may marginally increase the initial cost but has indirect effects like preventing delays in treatment and avoidance of false prescription of antibiotics. If the man-hours spent on repeat investigations are also taken into consideration, then the economic cost borne by the laboratory would also decrease manifold with the use of these containers.

  5. Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.

    PubMed

    Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A

    2011-03-01

    The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.

  6. Variability of Organophosphorous Pesticide Metabolite Levels in Spot and 24-hr Urine Samples Collected from Young Children during 1 Week

    PubMed Central

    Kogut, Katherine; Eisen, Ellen A.; Jewell, Nicholas P.; Quirós-Alcalá, Lesliam; Castorina, Rosemary; Chevrier, Jonathan; Holland, Nina T.; Barr, Dana Boyd; Kavanagh-Baird, Geri; Eskenazi, Brenda

    2012-01-01

    Background: Dialkyl phosphate (DAP) metabolites in spot urine samples are frequently used to characterize children’s exposures to organophosphorous (OP) pesticides. However, variable exposure and short biological half-lives of OP pesticides could result in highly variable measurements, leading to exposure misclassification. Objective: We examined within- and between-child variability in DAP metabolites in urine samples collected during 1 week. Methods: We collected spot urine samples over 7 consecutive days from 25 children (3–6 years of age). On two of the days, we collected 24-hr voids. We assessed the reproducibility of urinary DAP metabolite concentrations and evaluated the sensitivity and specificity of spot urine samples as predictors of high (top 20%) or elevated (top 40%) weekly average DAP metabolite concentrations. Results: Within-child variance exceeded between-child variance by a factor of two to eight, depending on metabolite grouping. Although total DAP concentrations in single spot urine samples were moderately to strongly associated with concentrations in same-day 24-hr samples (r ≈ 0.6–0.8, p < 0.01), concentrations in spot samples collected > 1 day apart and in 24-hr samples collected 3 days apart were weakly correlated (r ≈ –0.21 to 0.38). Single spot samples predicted high (top 20%) and elevated (top 40%) full-week average total DAP excretion with only moderate sensitivity (≈ 0.52 and ≈ 0.67, respectively) but relatively high specificity (≈ 0.88 and ≈ 0.78, respectively). Conclusions: The high variability we observed in children’s DAP metabolite concentrations suggests that single-day urine samples provide only a brief snapshot of exposure. Sensitivity analyses suggest that classification of cumulative OP exposure based on spot samples is prone to type 2 classification errors. PMID:23052012

  7. Shift Work, Chronotype, and Melatonin Patterns among Female Hospital Employees on Day and Night Shifts.

    PubMed

    Leung, Michael; Tranmer, Joan; Hung, Eleanor; Korsiak, Jill; Day, Andrew G; Aronson, Kristan J

    2016-05-01

    Shift work-related carcinogenesis is hypothesized to be mediated by melatonin; however, few studies have considered the potential effect modification of this underlying pathway by chronotype or specific aspects of shift work such as the number of consecutive nights in a rotation. In this study, we examined melatonin patterns in relation to shift status, stratified by chronotype and number of consecutive night shifts, and cumulative lifetime exposure to shift work. Melatonin patterns of 261 female personnel (147 fixed-day and 114 on rotations, including nights) at Kingston General Hospital were analyzed using cosinor analysis. Urine samples were collected from all voids over a 48-hour specimen collection period for measurement of 6-sulfatoxymelatonin concentrations using the Buhlmann ELISA Kit. Chronotypes were assessed using mid-sleep time (MSF) derived from the Munich Chronotype Questionnaire (MCTQ). Sociodemographic, health, and occupational information were collected by questionnaire. Rotational shift nurses working nights had a lower mesor and an earlier time of peak melatonin production compared to day-only workers. More pronounced differences in mesor and acrophase were seen among later chronotypes, and shift workers working ≥3 consecutive nights. Among nurses, cumulative shift work was associated with a reduction in mesor. These results suggest that evening-types and/or shift workers working ≥3 consecutive nights are more susceptible to adverse light-at-night effects, whereas long-term shift work may also chronically reduce melatonin levels. Cumulative and current exposure to shift work, including nights, affects level and timing of melatonin production, which may be related to carcinogenesis and cancer risk. Cancer Epidemiol Biomarkers Prev; 25(5); 830-8. ©2016 AACR. ©2016 American Association for Cancer Research.

  8. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  9. Gene expression signature in urine for diagnosing and assessing aggressiveness of bladder urothelial carcinoma.

    PubMed

    Mengual, Lourdes; Burset, Moisès; Ribal, María José; Ars, Elisabet; Marín-Aguilera, Mercedes; Fernández, Manuel; Ingelmo-Torres, Mercedes; Villavicencio, Humberto; Alcaraz, Antonio

    2010-05-01

    To develop an accurate and noninvasive method for bladder cancer diagnosis and prediction of disease aggressiveness based on the gene expression patterns of urine samples. Gene expression patterns of 341 urine samples from bladder urothelial cell carcinoma (UCC) patients and 235 controls were analyzed via TaqMan Arrays. In a first phase of the study, three consecutive gene selection steps were done to identify a gene set expression signature to detect and stratify UCC in urine. Subsequently, those genes more informative for UCC diagnosis and prediction of tumor aggressiveness were combined to obtain a classification system of bladder cancer samples. In a second phase, the obtained gene set signature was evaluated in a routine clinical scenario analyzing only voided urine samples. We have identified a 12+2 gene expression signature for UCC diagnosis and prediction of tumor aggressiveness on urine samples. Overall, this gene set panel had 98% sensitivity (SN) and 99% specificity (SP) in discriminating between UCC and control samples and 79% SN and 92% SP in predicting tumor aggressiveness. The translation of the model to the clinically applicable format corroborates that the 12+2 gene set panel described maintains a high accuracy for UCC diagnosis (SN = 89% and SP = 95%) and tumor aggressiveness prediction (SN = 79% and SP = 91%) in voided urine samples. The 12+2 gene expression signature described in urine is able to identify patients suffering from UCC and predict tumor aggressiveness. We show that a panel of molecular markers may improve the schedule for diagnosis and follow-up in UCC patients. Copyright 2010 AACR.

  10. Development and evaluation of an enzyme-linked immunosorbent assay (ELISA) method for the measurement of 2,4-dichlorophenoxyacetic acid in human urine.

    PubMed

    Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent

    2005-09-15

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.

  11. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS.

    PubMed

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S

    2015-04-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS

    PubMed Central

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2014-01-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921

  13. A novel way to monitor urine concentration: fluorescent concentration matrices.

    PubMed

    Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton

    2015-01-01

    The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.

  14. Urinary microbiome of kidney transplant patients reveals dysbiosis with potential for antibiotic resistance

    PubMed Central

    Rani, Asha; Ranjan, Ravi; McGee, Halvor S.; Andropolis, Kalista E.; Panchal, Dipti V.; Hajjiri, Zahraa; Brennan, Daniel C.; Finn, Patricia W.; Perkins, David L.

    2016-01-01

    Recent studies have established that a complex community of microbes colonize the human urinary tract; however their role in kidney transplant patients treated with prophylactic antibiotics remains poorly investigated. Our aim was to investigate the urinary microbiome of kidney transplant recipients. Urine samples from 21 patients following kidney transplantation and 8 healthy controls, were collected. All patients received prophylactic treatment with the antibiotic trimethoprim/sulfamethoxazole. Metagenomic DNA was isolated from urine samples, sequenced using metagenomics shotgun sequencing approach on Illumina HiSeq2000 platform, and analyzed for microbial taxonomic and functional annotations. Our results demonstrate that the urine microbiome of kidney transplants was markedly different at all taxonomic levels from phyla to species, had decreased microbial diversity and increased abundance of potentially pathogenic species compared to healthy controls. Specifically, at the phylum level we detected a significant decrease in Actinobacteria and increase in Firmicutes due to increases in Enterococcus faecalis. In addition, there was an increase in the Proteobacteria due to increases in E. coli. Analysis of predicted functions of the urinary metagenome revealed increased abundance of enzymes in the folate pathway including dihydrofolate synthase that are not inhibited by trimethoprim/sulfamethoxazole, but can augment folate metabolism. This report characterizes the urinary microbiome of kidney transplants using shotgun metagenomics approach. Our results indicate that the urinary microbiota may be modified in the context of prophylactic antibiotics, indicating that a therapeutic intervention may shift the urinary microbiota to select bacterial species with increased resistance to antibiotics. The evaluation and development of optimal prophylactic regimens that do not promote antibiotic resistance is an important future goal. PMID:27669488

  15. Assessment of Welders Exposure to Carcinogen Metals from Manual Metal Arc Welding in Gas Transmission Pipelines, Iran

    PubMed Central

    Golbabaei, F; Seyedsomea, M; Ghahri, A; Shirkhanloo, H; Khadem, M; Hassani, H; Sadeghi, N; Dinari, B

    2012-01-01

    Background: Welding can produce dangerous fumes containing various metals especially carcinogenic ones. Occupational exposure to welding fumes is associated with lung cancer. Therefore, welders in Gas Transmission Pipelines are known as a high-risk group. This study was designed to determinate the amounts of metals Cr, Ni, and Cd in breathing zone and urine of welders and to assess the possibility of introducing urinary metals as a biomarker due to occupational exposure. Methods: In this cross sectional study, 94 individuals from Gas Transmission Pipelines welders, Iran, Borujen in 2011 were selected and classified into 3 groups including Welders, Back Welders and Assistances. The sampling procedures were performed according to NIOSH 7300 for total chromium, nickel, and cadmium and NIOSH 7600 for Cr+6. For all participants urine samples were collected during the entire work shift and metals in urine were determined according to NIOSH 8310. Results: Back Welders and Assistances groups had maximum and minimum exposure to total fume and its elements, respectively. In addition, results showed that there are significant differences (P<0.05) between Welders and Back Welders with Assistances group in exposure with total fume and elements except Ni. Urinary concentrations of three metals including Cr, Cd and Ni among all welders were about 4.5, 12 and 14-fold greater than those detected in controls, respectively. Weak correlations were found between airborne and urinary metals concentrations (R2: Cr=0.45, Cd=0.298, Ni=0.362). Conclusion: Urinary metals concentrations could not be considerate as a biomarker for welders’ exposure assessment. PMID:23113226

  16. Occupational exposure to manganese-containing welding fumes and pulmonary function indices among natural gas transmission pipeline welders.

    PubMed

    Hassani, Hamid; Golbabaei, Farideh; Ghahri, Asghar; Hosseini, Mostafa; Shirkhanloo, Hamid; Dinari, Behnam; Eskandari, Davood; Fallahi, Majid

    2012-01-01

    The objectives of this study were to evaluate manganese (Mn)-containing welding fumes' exposure, assess urinary Mn as a biomarker for Mn exposure and investigate the correlation of Mn in air, total fumes and urinary Mn with pulmonary function indices in 118 welders and 37 unexposed controls from two regions in Iran, Assaluyeh and Borujen. Air samples were collected on mixed cellulose ester membrane filters in personal air samplers and then analyzed using inductively coupled plasma atomic emission spectroscopy (ICP-AES) (NIOSH Method 7300). For all participants, urine samples were collected during the entire work shift, and Mn in urine was determined by graphite furnace atomic absorption spectroscopy according to NIOSH Method 8310. Spirometric measurements were also done for participants. The maximum exposures to airborne Mn and total fumes were 0.304 ± 0.256 mg/m(3) and 21.52 ± 9.40 mg/m(3), respectively. The urine Mn levels in the various groups ranged between 0.77 to 7.58 μg/l. The correlation between airborne Mn and urinary Mn was significant for total whole participants. Some values of spirometric indices were statistically lower in welders rather than controls. Our results indicate that many welders have been exposed to higher concentrations of Mn-containing welding fumes. Urinary Mn can be used as a biomarker for Mn exposure. There were weak inverse correlations between Mn-containing welding fumes and pulmonary function indices, and the inverse correlation between urinary Mn with forced vital capacities (FVC) and forced expiratory volume in 1 s (FEV1) was significant.

  17. Assessment of welders exposure to carcinogen metals from manual metal arc welding in gas transmission pipelines, iran.

    PubMed

    Golbabaei, F; Seyedsomea, M; Ghahri, A; Shirkhanloo, H; Khadem, M; Hassani, H; Sadeghi, N; Dinari, B

    2012-01-01

    Welding can produce dangerous fumes containing various metals especially carcinogenic ones. Occupational exposure to welding fumes is associated with lung cancer. Therefore, welders in Gas Transmission Pipelines are known as a high-risk group. This study was designed to determinate the amounts of metals Cr, Ni, and Cd in breathing zone and urine of welders and to assess the possibility of introducing urinary metals as a biomarker due to occupational exposure. In this cross sectional study, 94 individuals from Gas Transmission Pipelines welders, Iran, Borujen in 2011 were selected and classified into 3 groups including Welders, Back Welders and Assistances. The sampling procedures were performed according to NIOSH 7300 for total chromium, nickel, and cadmium and NIOSH 7600 for Cr+6. For all participants urine samples were collected during the entire work shift and metals in urine were determined according to NIOSH 8310. Back Welders and Assistances groups had maximum and minimum exposure to total fume and its elements, respectively. In addition, results showed that there are significant differences (P<0.05) between Welders and Back Welders with Assistances group in exposure with total fume and elements except Ni. Urinary concentrations of three metals including Cr, Cd and Ni among all welders were about 4.5, 12 and 14-fold greater than those detected in controls, respectively. Weak correlations were found between airborne and urinary metals concentrations (R2: Cr=0.45, Cd=0.298, Ni=0.362). Urinary metals concentrations could not be considerate as a biomarker for welders' exposure assessment.

  18. Biomonitoring-based exposure assessment of benzene, toluene, ethylbenzene and xylene among workers at petroleum distribution facilities.

    PubMed

    Heibati, Behzad; Godri Pollitt, Krystal J; Charati, Jamshid Yazdani; Ducatman, Alan; Shokrzadeh, Mohammad; Karimi, Ali; Mohammadyan, Mahmoud

    2018-03-01

    Elevated emissions of volatile organic compounds, including benzene, toluene, ethylbenzene, and o, p, and m-xylenes (BTEX), are an occupational health concern at oil transfer stations. This exploratory study investigated personal exposure to BTEX through environmental air and urine samples collected from 50 male workers at a major oil distribution company in Iran. Airborne BTEX exposures were evaluated over 8h periods during work-shift by using personal passive samplers. Urinary BTEX levels were determined using solid-phase microextraction with gas chromatography mass spectrometry for separation and detection. Mean exposure to ambient concentrations of benzene differed by workers' job type: tanker loading workers (5390μg/m 3 ), tank-gauging workers (830μg/m 3 ), drivers (81.9μg/m 3 ), firefighters (71.2μg/m 3 ) and office workers (19.8μg/m 3 ). Exposure across job type was similarly stratified across all personal exposures to BTEX measured in air samples with maximum concentrations found for tanker loading workers. Average exposures concentrations of BTEX measured in urine were 11.83 ppb benzene, 1.87 ppb toluene, 0.43 ppb ethylebenzene, and 3.76 ppb xylene. Personal air exposure to benzene was found to be positively associated with benzene concentrations measured in urine; however, a relationship was not observed to the other BTEX compounds. Urinary exposure profiles are a potentially useful, noninvasive, and rapid method for assessing exposure to benzene in a developing and relatively remote production region. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes.

    PubMed

    Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J

    2015-04-22

    Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.

  20. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990

  1. Daily sodium and potassium excretion can be estimated by scheduled spot urine collections.

    PubMed

    Doenyas-Barak, Keren; Beberashvili, Ilia; Bar-Chaim, Adina; Averbukh, Zhan; Vogel, Ofir; Efrati, Shai

    2015-01-01

    The evaluation of sodium and potassium intake is part of the optimal management of hypertension, metabolic syndrome, renal stones, and other conditions. To date, no convenient method for its evaluation exists, as the gold standard method of 24-hour urine collection is cumbersome and often incorrectly performed, and methods that use spot or shorter collections are not accurate enough to replace the gold standard. The aim of this study was to evaluate the correlation and agreement between a new method that uses multiple-scheduled spot urine collection and the gold standard method of 24-hour urine collection. The urine sodium or potassium to creatinine ratios were determined for four scheduled spot urine samples. The mean ratios of the four spot samples and the ratios of each of the single spot samples were corrected for estimated creatinine excretion and compared to the gold standard. A significant linear correlation was demonstrated between the 24-hour urinary solute excretions and estimated excretion evaluated by any of the scheduled spot urine samples. The correlation of the mean of the four spots was better than for any of the single spots. Bland-Altman plots showed that the differences between these measurements were within the limits of agreement. Four scheduled spot urine samples can be used as a convenient method for estimation of 24-hour sodium or potassium excretion. © 2015 S. Karger AG, Basel.

  2. Personal exposure to particulate PAHs and anthraquinone and oxidative DNA damages in humans.

    PubMed

    Wei, Yongjie; Han, In-Kyu; Hu, Min; Shao, Min; Zhang, Junfeng Jim; Tang, Xiaoyan

    2010-11-01

    Recent studies suggest that DNA oxidative damage be related to the chemical constituents of ambient particles. The purpose of this study was to examine whether particulate polycyclic aromatic hydrocarbons (PAHs) and quinone-structure chemicals increase body burden of oxidative stress in human exposed to heavy traffic volume. We recruited two nonsmoking security guards who worked at a university campus gate near a heavily trafficked road. Each subject wore a personal air sampler for 24h per day to estimate exposures to 24 PAHs and anthraquinone (AnQ) in PM(2.5). Daily pre- and post-work shift spot urines were collected for 29d from each subject. Urine samples were analyzed for 8-hydroxy-2'-deoxyguanosine (8-OHdG). Additionally, using 19 organic tracers other than 24 PAHs and AnQ, a receptor source apportionment model of chemical mass balance was applied to determine the contributions of sources on the PM: gasoline vehicle, diesel vehicle, coal burning, vegetable debris, cooking, natural gas and biomass burning. The relationship among urinary 8-OHdG, individual PAH, and AnQ was demonstrated as follows: the average urinary concentration of 8-OHdG was increased more than three times after 8-h work-shift than those before the work shift. All the 24 PAH and AnQ levels were positively and significantly associated with the post-work urinary 8-OHdG. The results from source apportionment suggest vehicular emission to be the dominant source of personal exposure to PM(2.5). Our finding indicates that personal air exposures to 24 individual PAHs and AnQ originating from traffic emissions are important in increasing oxidative burdens in human body. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Estimating population salt intake in India using spot urine samples.

    PubMed

    Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce

    2017-11-01

    To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.

  4. Space motion sickness medications: interference with biomedical parameters

    NASA Technical Reports Server (NTRS)

    Vernikos-Danellis, J.; Winget, C. M.; Leach, C. S.; Rosenblatt, L. S.; Lyman, J.; Beljan, J. R.

    1977-01-01

    The possibility that drugs administered to Skylab 3 (SL-3) and 4 (SL-4) crewmen for space motion sickness may have interfered with their biomedical evaluation in space was investigated. Healthy volunteers received combinations of Scopolamine/Dexedrine for four days in regimens similar to those used in these missions. Urine samples, heart rate, body temperature, mood and performance were analyzed for drug-related changes. Twenty-four hour urine samples were analyzed by the same procedures as those used to analyze the flight samples. Hormone concentrations determined included cortisol, epinephrine, norepinephrine, aldosterone and antidiuretic hormone (ADH). In addition, volume, specific gravity, osmolarity, sodium (Na), potassium (K), calcium (Ca), magnesium (Mg), chloride (Cl), inorganic phosphate, uric acid and creatinine were measured. Performance was not affected by the Scopolamine/Dexedrine. The drug combination increased daily mean heart rate (HR) significantly in all the subjects and daily mean rectal temperature (RT) in some of the subjects. A 2-4 hr phase shift in the HR circadian rhythm was also observed which indicates that internal circadian synchrony was disturbed by the drugs. Psychological and subjective evaluation indicated that the subjects could usually identify which days they were given the drugs by an increase in tension and anxiety, decreased patience, restlessness, decreased appetite, difficulty in sleeping and feelings of increased heart rate and body temperature. Urinary electrolytes were not changed significantly by the drug, but marked and significant changes occurred in urine volume and hormone excretion patterns. Scopolamine/Dexedrine caused consistent elevations in urinary cortisol and epinephrine and a transient elevation in ADH. Norepinephrine excretion was decreased, but there was no significant change in aldosterone excretion or in 24 hr urine volume. A comparison of these findings with the first four days of inflight data from the SL-3 and SL-4 missions leads to the conclusion that the dramatic increases in aldosterone excretion during the first three days of spaceflight probably can be directly attributed to weightlessness, whereas the antimotion sickness medication could have substantially contributed to the early increased excretion of epinephrine and cortisol during these missions.

  5. Simple DNA extraction of urine samples: Effects of storage temperature and storage time.

    PubMed

    Ng, Huey Hian; Ang, Hwee Chen; Hoe, See Ying; Lim, Mae-Lynn; Tai, Hua Eng; Soh, Richard Choon Hock; Syn, Christopher Kiu-Choong

    2018-06-01

    Urine samples are commonly analysed in cases with suspected illicit drug consumption. In events of alleged sample mishandling, urine sample source identification may be necessary. A simple DNA extraction procedure suitable for STR typing of urine samples was established on the Promega Maxwell ® 16 paramagnetic silica bead platform. A small sample volume of 1.7mL was used. Samples were stored at room temperature, 4°C and -20°C for 100days to investigate the influence of storage temperature and time on extracted DNA quantity and success rate of STR typing. Samples stored at room temperature exhibited a faster decline in DNA yield with time and lower typing success rates as compared to those at 4°C and -20°C. This trend can likely be attributed to DNA degradation. In conclusion, this study presents a quick and effective DNA extraction protocol from a small urine volume stored for up to 100days at 4°C and -20°C. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Exploring the concurrent presence of hepatitis A virus genome in serum, stool, saliva, and urine samples of hepatitis A patients.

    PubMed

    Joshi, Madhuri S; Bhalla, Shilpa; Kalrao, Vijay R; Dhongade, Ramchandra K; Chitambar, Shobha D

    2014-04-01

    The use of saliva and urine as an alternative to serum samples for detection of anti-hepatitis A virus (HAV) IgM antibodies has been documented. However, these samples remain underreported or unexplored for shedding of HAV. To address this issue, paired serum, stool, saliva, and urine samples collected from hepatitis A patients were screened by reverse transcription polymerase chain reaction for detection of HAV RNA. HAV RNA was detected in 67.6% (44/65), 52.3% (34/65), 8.7% (5/57), and 12.3% (8/65) of the serum, stool, saliva, and urine samples, respectively. Phylogenetic analysis of nucleotide sequences obtained for partial RNA polymerase region grouped HAV strains from all of the clinical samples of the study in subgenotype IIIA. Low frequency of HAV nucleic acid in saliva and urine samples indicates limited utility of these samples in genomic studies on HAV but suggests its potential for transmission and infection of hepatitis A. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Exposure of aircraft maintenance technicians to organophosphates from hydraulic fluids and turbine oils: a pilot study.

    PubMed

    Schindler, Birgit Karin; Koslitz, Stephan; Weiss, Tobias; Broding, Horst Christoph; Brüning, Thomas; Bünger, Jürgen

    2014-01-01

    Hydraulic fluids and turbine oils contain organophosphates like tricresyl phosphate isomers, triphenyl phosphate and tributyl phosphate from very small up to high percentages. The aim of this pilot study was to determine if aircraft maintenance technicians are exposed to relevant amounts of organophosphates. Dialkyl and diaryl phosphate metabolites of seven organophosphates were quantified in pre- and post-shift spot urine samples of technicians (N=5) by GC-MS/MS after solid phase extraction and derivatization. Pre- and post shift values of tributyl phosphate metabolites (dibutyl phosphate (DBP): median pre-shift: 12.5 μg/L, post-shift: 23.5 μg/L) and triphenyl phosphate metabolites (diphenyl phosphate (DPP): median pre-shift: 2.9 μg/L, post-shift: 3.5 μg/L) were statistically higher than in a control group from the general population (median DBP: <0.25 μg/L, median DPP: 0.5 μg/L). No tricresyl phosphate metabolites were detected. The aircraft maintenance technicians were occupationally exposed to tributyl and triphenyl phosphate but not to tricresyl phosphate, tri-(2-chloroethyl)- and tri-(2-chloropropyl)-phosphate. Further studies are necessary to collect information on sources, routes of uptake and varying exposures during different work tasks, evaluate possible health effects and to set up appropriate protective measures. Copyright © 2013 Elsevier GmbH. All rights reserved.

  8. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    PubMed

    Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  9. A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection

    PubMed Central

    Bordelon, Hali; Russ, Patricia K.; Wright, David W.; Haselton, Frederick R.

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×103 to 5×108 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×106, 14×106, and 8×106 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR. PMID:23861895

  10. The examination of urine samples for pathogenic microbes by the luciferase assay for ATP. 1: The effect of the presence of fungi, fungal like bacteria and kidney cells in urine samples

    NASA Technical Reports Server (NTRS)

    Bush, V. N.

    1973-01-01

    A method for accurately determining urinary tract infections in man is introduced. The method is based on adenosine triphosphate (ATP) concentration in urine samples after removing nonbacterial ATP. Adenosine triphosphate concentration is measured from the bioluminescent reaction of luciferase when mixed with ATP. An examination was also made of the effectiveness of rupturing agents on monkey kidney cells Candia albicans, a Rhodotorula species, and a Streptomyces species in determining whether these cells could contribute ATP to the bacterial ATP value of a urine sample.

  11. Development of an immunochromatographic assay for the β-adrenergic agonist feed additive zilpaterol.

    PubMed

    Shelver, Weilin L; Smith, David J

    2018-06-06

    Zilpaterol is a β-adrenergic agonist feed additive approved in the United States to increase weight gain and improve feed efficiency of cattle. A zilpaterol immunochromatographic assay was developed as an economical and user-friendly rapid detection method for zilpaterol and validated using urine and tissue samples derived from animal studies. The assay sensitivity was 1.7-23.2 ng g -1 or mL -1 across a variety of feed and animal matrices and did not cross-react with clenbuterol or ractopamine. No sample pre-treatment of cattle and sheep urine was needed, but horse urine and feed required dilution; skeletal muscle required solvent extraction prior to testing. Of 32 incurred sheep urine samples tested, zilpaterol content was correctly identified in all but 2 samples. Horse urine containing >10 ng mL -1 of incurred zilpaterol residue (n = 48) was correctly identified as zilpaterol positive. The assay correctly identified 0-day withdrawal sheep muscle samples as zilpaterol positive and the control and longer withdrawal day sheep muscle samples as negative. Zilpaterol was demonstrated to be stable in horse urine when stored at -20°C for 7 years.

  12. Quantification of sulfatides in dried blood and urine spots from metachromatic leukodystrophy patients by liquid chromatography/electrospray tandem mass spectrometry.

    PubMed

    Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H

    2014-06-10

    Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. USE OF DISPOSABLE DIAPERS TO COLLECT URINE IN EXPOSURE STUDIES

    EPA Science Inventory

    Large studies of children's health as it relates to exposures to chemicals in the environment often require measurements of biomarkers of chemical exposures or effects in urine samples. But collection of urine samples from infants and toddlers is difficult. For large exposure s...

  14. The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative

    NASA Technical Reports Server (NTRS)

    Nillen, Jeannie L.; Smith, Scott M.

    2003-01-01

    A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.

  15. Biological monitoring and the influence of genetic polymorphism of As3MT and GSTs on distribution of urinary arsenic species in occupational exposure workers.

    PubMed

    Janasik, Beata; Reszka, Edyta; Stanislawska, Magdalena; Wieczorek, Edyta; Fendler, Wojciech; Wasowicz, Wojciech

    2015-08-01

    To examine the differences in urinary arsenic metabolism patterns in men affected by occupational exposure, we performed a study on 149 participants—workers of a copper mill and 52 healthy controls without occupational exposure. To elucidate the role of genetic factors in arsenic (As) metabolism, we studied the associations of six polymorphisms: As3MT Met287Thr (T>C) in exon 9; As3MT A>G in 5'UTR; As3MT C>G in intron 6; As3MT T>G in intron 1; GSTP1 Ile105Val and GSTO2 T>C. Air samples were collected using individual samplers during work shift. Urine samples were analyzed for total arsenic and arsenic chemical forms (As(III); As(V), MMA, DMA, AsB) using HPLC-ICP-MS. A specific polymerase chain reaction was done for the amplification of exons and flanking regions of As3MT and GSTs. The geometric mean arsenic concentrations in the air were 27.6 ± 4.9 µg/m(3). A significant correlation (p < 0.05) was observed between arsenic in air and sum of iAs +MMA and iAs. As3MT (rs3740400) GG homozygotes showed significantly (p < 0.05) higher %iAs (21.8 ± 2.0) in urine than GC+CC heterozygotes (16.0 ± 2.1). A strong association between the gene variants and As species in urine was observed for GSTO2 (rs156697) polymorphism. The findings of the study point out that the concentration of iAs or the sum of iAs + MMA in urine can be a reliable biological indicator of occupational exposure to arsenic. This study demonstrates that As3MT and/or GSTs genotype may influence As metabolism. Nevertheless, further studies investigating genetic polymorphism in occupational conditions are required.

  16. Glucose urine test

    MedlinePlus

    Urine sugar test; Urine glucose test; Glucosuria test; Glycosuria test ... After you provide a urine sample, it is tested right away. The health care provider uses a dipstick made with a color-sensitive pad. The ...

  17. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Aldosterone - urine; Addison disease - urine aldosterone; Cirrhosis - serum aldosterone ... A 24-hour urine sample is needed. You will need to collect your urine over 24 hours . Your health care provider will tell ...

  18. Temporal variability of urinary cadmium in spot urine samples and first morning voids.

    PubMed

    Vacchi-Suzzi, Caterina; Porucznik, Christina A; Cox, Kyley J; Zhao, Yuan; Ahn, Hongshik; Harrington, James M; Levine, Keith E; Demple, Bruce; Marsit, Carmen J; Gonzalez, Adam; Luft, Benjamin; Meliker, Jaymie R

    2017-05-01

    Cadmium is a carcinogenic heavy metal. Urinary levels of cadmium are considered to be an indicator of long-term body burden, as cadmium accumulates in the kidneys and has a half-life of at least 10 years. However, the temporal stability of the biomarker in urine samples from a non-occupationally exposed population has not been rigorously established. We used repeated measurements of urinary cadmium (U-Cd) in spot urine samples and first morning voids from two separate cohorts, to assess the temporal stability of the samples. Urine samples from two cohorts including individuals of both sexes were measured for cadmium and creatinine. The first cohort (Home Observation of Perinatal Exposure (HOPE)) consisted of 21 never-smokers, who provided four first morning urine samples 2-5 days apart, and one additional sample roughly 1 month later. The second cohort (World Trade Center-Health Program (WTC-HP)) consisted of 78 individuals, including 52 never-smokers, 22 former smokers and 4 current smokers, who provided 2 spot urine samples 6 months apart, on average. Intra-class correlation was computed for groups of replicates from each individual to assess temporal variability. The median creatinine-adjusted U-Cd level (0.19 and 0.21 μg/g in the HOPE and WTC-HP, respectively) was similar to levels recorded in the United States by the National Health and Nutrition Examination Survey. The intra-class correlation (ICC) was high (0.76 and 0.78 for HOPE and WTC-HP, respectively) and similar between cohorts, irrespective of whether samples were collected days or months apart. Both single spot or first morning urine cadmium samples show good to excellent reproducibility in low-exposure populations.

  19. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    PubMed

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  20. Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.

    PubMed

    Faraji, Hakim; Helalizadeh, Masoumeh

    2017-04-01

    Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.

  1. Rapid Diagnosis of Tuberculosis from Analysis of Urine Volatile Organic Compounds

    PubMed Central

    Lim, Sung H.; Martino, Raymond; Anikst, Victoria; Xu, Zeyu; Mix, Samantha; Benjamin, Robert; Schub, Herbert; Eiden, Michael; Rhodes, Paul A.; Banaei, Niaz

    2017-01-01

    The World Health Organization has called for simple, sensitive, and non-sputum diagnostics for tuberculosis. We report development of a urine tuberculosis test using a colorimetric sensor array (CSA). The sensor comprised of 73 different indicators captures high-dimensional, spatiotemporal signatures of volatile chemicals emitted by human urine samples. The sensor responses to 63 urine samples collected from 22 tuberculosis cases and 41 symptomatic controls were measured under five different urine test conditions. Basified testing condition yielded the best accuracy with 85.5% sensitivity and 79.5% specificity. The CSA urine assay offers desired features needed for tuberculosis diagnosis in endemic settings. PMID:29057329

  2. Can nail, hair and urine be used for biomonitoring of human exposure to perfluorooctane sulfonate and perfluorooctanoic acid?

    PubMed

    Li, Jingguang; Guo, Feifei; Wang, Yuxin; Zhang, Jialing; Zhong, Yuxin; Zhao, Yunfeng; Wu, Yongning

    2013-03-01

    Because of the disadvantages of invasive sampling, it is desirable to explore non-invasive matrices for human biomonitoring of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). The aim of this study was to evaluate the application of nail, hair and urine for human biomonitoring of PFOS and PFOA. The concentrations of PFOS and PFOA in matched nail, hair, urine and serum samples collected from 64 donors were measured. The chemicals of interest were detected with high detection frequency in these matrices (90%-100%) except for PFOA in urine samples (56%). Generally, the gender influences on the levels of PFOS and PFOA in these non-invasive matrices were in agreement with that in serum. For PFOS, the coefficients of Spearman correlation between serum samples and nail, hair and urine samples were 0.786 (p<0.001), 0.545 (p<0.001) and 0.302 (p<0.05), respectively. For PFOA, the correlation was only observed between nail samples and serum samples with a correlation coefficient of 0.299 (p<0.05). The results suggested that nail has more potential than hair and urine to be applied in human biomonitoring for PFOS and PFOA in general populations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Manganese in plasma: a promising biomarker of exposure to Mn in welders. A pilot study.

    PubMed

    Hoet, Perrine; Vanmarcke, Els; Geens, Tom; Deumer, Gladys; Haufroid, Vincent; Roels, Harry A

    2012-08-13

    There is raising concern about the potential neurotoxic effects of manganese (Mn) inhalation exposure in welders. Because most of the airborne particles in welding fume are in the respirable fraction, their bioavailability is likely to be higher than for coarser dust exposure. No well-validated biomarker for Mn exposure is available. To investigate the interest of measuring Mn in plasma (Mn-P) and urine (Mn-U) as biomarkers of exposure in a group of 28 welders whose tasks were only welding-related. Ambient air exposure to Mn (Mn-air) was determined by personal full-shift measurements on Monday and Tuesday. On the same days, blood and urine samples were collected before and after the shift. Mn-air varied from 1.3 to 729 μg/m(3) (GM 27.7). For Mn-U 65% of the values in welders were below the LOQ (0.20 μg/L). Compared to controls, the welders' Mn-P averaged 33% higher (1.5 vs 2.0 μg/L). In welders, the after-shift Mn-P values correlated well with Mn-air above 10 μg/m(3). In spite of similar Mn-air exposure on Monday and Tuesday, the relationships between Mn-air and after-shift Mn-P strikingly differed on Tuesday in that the inflection in the relationship was less obvious and the slope of the regression line (Mn-P after-shift/logMn-air) for a doubling of logMn-air was 2.3 times lower than on Monday. On Monday (the first day of the workweek), a Mn-P value of 2 μg/L could distinguish Mn-air exposure above or below 20 μg/m(3) with a sensitivity of 69% and a specificity of 82%. This preliminary study indicates that Mn-P is a promising biomarker of current exposure to Mn in welders and lends biological plausibility to the intended change for the Mn TLV-TWA of 20 μg/m(3) proposed by ACGIH for respirable Mn particulate. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. Effect of injected rotenone on the production and composition of urine from the rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Erickson, D.A.; Gingerich, W.H.

    1986-01-01

    Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.

  5. NHEXAS PHASE I MARYLAND STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 9 pesticides in 345 urine samples over 79 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning ...

  6. NHEXAS PHASE I ARIZONA STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 4 pesticide metabolites in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. ...

  7. The resident microflora of voided midstream urine of healthy controls: standard versus expanded urine culture protocols.

    PubMed

    Coorevits, L; Heytens, S; Boelens, J; Claeys, G

    2017-04-01

    The workup and interpretation of urine cultures is not always clear-cut, especially for midstream samples contaminated with commensals. Standard urine culture (SUC) protocols are designed in favor of growth of uropathogens at the expense of commensals. In selected clinical situations, however, it is essential to trace fastidious or new uropathogens by expanding the urine culture conditions (EUC). The aim of our study was to map the microflora in midstream urine specimens from healthy controls by means of EUC, in view of the interpretation of bacterial culture results in symptomatic patients. Midstream urine specimens from 101 healthy controls (86 females and 15 males) were examined using both SUC and EUC. Whilst 73 % of samples examined by SUC showed no growth at 10 3  colony-forming units (CFU)/mL, 91 % of samples examined by EUC grew bacterial species in large numbers (≥10 4  CFU/mL). Asymptomatic bacteriuria, as defined by the European guidelines for urinalysis, was detected in six samples with both protocols. EUC revealed 98 different species, mostly Lactobacillus, Staphylococcus, Streptococcus, and Corynebacterium. None of the samples grew Staphylococcus saprophyticus, Corynebacterium urealyticum, or Aerococcus urinae. Samples from females contained higher bacterial loads and showed higher bacterial diversity compared to males. Midstream urine of healthy controls contains large communities of living bacteria that comprise a resident microflora, only revealed by EUC. Hence, the use of EUC instead of SUC in a routine setting would result in more sensitive but less specific results, requiring critical interpretation. In our view, EUC should be reserved for limited indications.

  8. Influence of storage conditions on aluminum concentrations in serum, dialysis fluid, urine, and tap water.

    PubMed

    Wilhelm, M; Ohnesorge, F K

    1990-01-01

    The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.

  9. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    PubMed

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.

  10. Detection of Novel Visible-Light Region Absorbance Peaks in the Urine after Alkalization in Patients with Alkaptonuria

    PubMed Central

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Background Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. Methods We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Results Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. Conclusions We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria. PMID:24466168

  11. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  12. Diagnostic utility and cost-effectiveness of reflex bacterial culture for the detection of urinary tract infection in dogs with low urine specific gravity.

    PubMed

    Tivapasi, Musavenga T; Hodges, Joanne; Byrne, Barbara A; Christopher, Mary M

    2009-09-01

    Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)< or =1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost-effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California-Davis Veterinary Medical Teaching Hospital for samples with USG< or =1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost-effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost-effective in dogs with USG< or =1.013 in the absence of active urine sediment or high clinical suspicion for UTI.

  13. Biological monitoring of glazers exposed to lead in the ceramics industry in Iran.

    PubMed

    Shouroki, Fatemeh Kargar; Shahtaheri, Seyed Jamaleddin; Golbabaei, Farideh; Barkhordari, Abolfazle; Rahimi-Froushani, Abbas

    2015-01-01

    Exposure to heavy metals, particularly lead, takes place in the ceramics industry. Lead is used in glaze to produce smooth and brilliant surfaces; thus, there is a likelihood of occupational adverse effects on humans. Urine samples were collected from 49 glazers at the start and end of the work shifts (98 samples). Solid phase extraction was used for separation and pre-concentration of the analyte. Samples were analysed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Lung function tests were performed on both control and lead exposed subjects. Statistical analysis of covariance (ANCOVA) was used to evaluate the data obtained. The concentration of lead in glazers was 6.37 times higher than in the control group. Lung functions were significantly lower in the glazers compared to the control group (p < 0.001). Results showed that poor ventilation systems, overtime work and work history are effective determinants of high exposure levels.

  14. Urinalysis in children and adolescents.

    PubMed

    Utsch, Boris; Klaus, Günter

    2014-09-12

    Urinalysis is the most commonly performed biochemical test in infancy and early childhood. The urine sample should be correctly obtained, age-specific aspects should be considered, and age-dependent reference values should be used. This review is based on a selective literature search in electronic databases, textbooks, and guidelines from Germany and abroad on the acquisition of urine samples and the performance of urinalysis in infancy and early childhood. The timing and mode of acquisition of the urine sample affect the assessment of hematuria, proteinuria, leukocyturia, nitrituria, and the uropathogenic bacterial colony count in the urine culture. Dipstick tests can be used for targeted screening for these features. The test results should be interpreted together with the findings of urine microscopy, the medical history, and the physical examination. Proteinuria should be quantified and differentiated; both of these things can be done either from collected urine or (especially in infants and young children) from a spontaneously voided urine sample, by determination of the protein/creatinine quotient. Orthostatic proteinuria in an adolescent requires no further evaluation or treatment. Hematuria should be characterized as either glomerular or non-glomerular erythrocyturia. Asymptomatic, isolated microhematuria in childhood is not uncommon and often transient; in the absence of a family history, it usually does not require an extensive work-up. Proteinuria combined with hematuria should arouse the suspicion of glomerulonephritis. Urinalysis in infancy and early childhood is a simple and informative diagnostic test as long as the urine sample has been obtained properly and the results are interpreted appropriately for this age group.

  15. Comparison of osmolality and refractometric readings of Hispaniolan Amazon parrot (Amazona ventralis) urine.

    PubMed

    Brock, A Paige; Grunkemeyer, Vanessa L; Fry, Michael M; Hall, James S; Bartges, Joseph W

    2013-12-01

    To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.

  16. Pyrazine Analogues Are Active Components of Wolf Urine That Induce Avoidance and Freezing Behaviours in Mice

    PubMed Central

    Osada, Kazumi; Kurihara, Kenzo; Izumi, Hiroshi; Kashiwayanagi, Makoto

    2013-01-01

    Background The common grey wolf (Canis lupus) is found throughout the entire Northern hemisphere and preys on many kinds of mammals. The urine of the wolf contains a number of volatile constituents that can potentially be used for predator–prey chemosignalling. Although wolf urine is put to practical use to keep rabbits, rodents, deer and so on at bay, we are unaware of any prior behavioural studies or chemical analyses regarding the fear-inducing impact of wolf urine on laboratory mice. Methodology/Principal Findings Three wolf urine samples harvested at different times were used in this study. All of them induced stereotypical fear-associated behaviors (i.e., avoidance and freezing) in female mice. The levels of certain urinary volatiles varied widely among the samples. To identify the volatiles that provoked avoidance and freezing, behavioural, chemical, and immunohistochemical analyses were performed. One of the urine samples (sample C) had higher levels of 2,6-dimethylpyrazine (DMP), trimethylpyrazine (TMP), and 3-ethyl-2,5-dimethyl pyrazine (EDMP) compared with the other two urine samples (samples A and B). In addition, sample C induced avoidance and freezing behaviours more effectively than samples A and B. Moreover, only sample C led to pronounced expression of Fos-immunoreactive cells in the accessory olfactory bulb (AOB) of female mice. Freezing behaviour and Fos immunoreactivity were markedly enhanced when the mice were confronted with a mixture of purified DMP, TMP, and EDMP vs. any one pyrazine alone. Conclusions/Significance The current results suggest that wolf urinary volatiles can engender aversive and fear-related responses in mice. Pyrazine analogues were identified as the predominant active components among these volatiles to induce avoidance and freezing behaviours via stimulation of the murine AOB. PMID:23637901

  17. Evidence for false-positive results for boldenone testing of veal urine due to faecal cross-contamination during sampling.

    PubMed

    Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G

    2004-08-01

    European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.

  18. NHEXAS PHASE I MARYLAND STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 3 metals in 376 urine samples over 80 households. Each sample was collected from the primary respondent within each household during the study and represented the first morning void of either Day ...

  19. Variations in Sleep and Performance by Duty Start Time in Short Haul Operations

    NASA Technical Reports Server (NTRS)

    Flynn-Evans, Erin

    2016-01-01

    Prior studies have confirmed that commercial airline pilots experience circadian phase shifts and short sleep duration following travel with layovers in different time zones. Few studies have examined the impact of early and late starts on the sleep and circadian phase of airline pilots who return to their domicile after each duty period. We recruited 44 pilots (4 female) from a short-haul commercial airline to participate in a study examining sleep and circadian phase over four duty schedules (baseline, early starts, mid-day starts, late starts). Each duty schedule was five days long, separated by three rest days. Participants completed the rosters in the same order. Sleep outcomes were estimated using wrist-borne actigraphy (Actiware Software, Respironics, Bend, OR) and daily sleep diaries. Thirteen participants volunteered to collect urine samples for the assessment of 6-sulfatoxymelatonin (aMT6s). Urine samples were collected in four-hourly bins during the day and eight-hourly bins during sleep episodes, for 24 hours immediately following each experimental duty schedule. The aMT6s results were fit to a cosine in order to obtain the acrophase to estimate circadian phase. Univariate statistics were calculated for acrophase changes, schedule start times and sleep times. All statistical analyses were computed using SAS software (Cary, IN).

  20. Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples

    PubMed Central

    Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely

    2008-01-01

    Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients. Moreover, PCR has enabled us to use residue volumes of urine samples collected by non invasive, non sterile methods, what is technically adequate as GBS is not part of the normal urine flora, thus avoiding invasive procedures such as suprapubic bladder punction or transurethral catheterization. At the same time, the use of urine instead of blood samples could help preventing newborns blood spoliation. PMID:24031170

  1. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  2. The Diagnostic Accuracy of Urine-Based Xpert MTB/RIF in HIV-Infected Hospitalized Patients Who Are Smear-Negative or Sputum Scarce

    PubMed Central

    Peter, Jonathan G.; Theron, Grant; Muchinga, Tapuwa E.; Govender, Ureshnie; Dheda, Keertan

    2012-01-01

    Background Hospitals in sub-Saharan Africa are inundated with HIV-infected patients and tuberculosis (TB) is the commonest opportunistic infection in this sub-group. Up to one third of TB-HIV co-infected patients fail to produce a sputum sample (sputum scarce) and diagnosis is thus often delayed or missed. We investigated the sensitivity of urine-based methods (Xpert MTB/RIF, LAM strip test and LAM ELISA) in such patients. Methodology/Principal Findings 281 HIV-infected hospitalised patients with clinically suspected TB provided a spot urine sample. The reference standard was culture positivity for Mycobacterium tuberculosis on ≥1 sputum or extra-pulmonary sample. MTB/RIF was performed using 1 ml of both unprocessed and, when possible, concentrated urine. Each unconcentrated urine sample was also tested using the Clearview LAM ELISA and Alere LAM strip test. 42% (116/242) of patients had culture-proven TB. 18% (20/54) were sputum scarce. In sputum-scarce patients, the sensitivity of urine MTB/RIF and LAM ELISA was 40% (95%CI: 22–61) and 60% (95%CI: 39–78), respectively. Urine MTB/RIF specificity was 98% (95%CI: 95–100). Combined sensitivity of urine LAM ELISA and MTB/RIF was better than MTB/RIF alone [MTB/RIF and LAM: 70% (95%CI: 48–85) vs. MTB/RIF: 40% (95%CI: 22–61), p = 0.03]. Significant predictors of urine MTB/RIF positivity were CD4<50 cells/ml (p = 0.001), elevated protein-to-creatinine ratio (p<0.001) and LAM ELISA positivity (p<0.001). Urine centrifugation and pelleting significantly increased the sensitivity of MTB/RIF over unprocessed urine in paired samples [42% (95%CI: 26–58) vs. 8% (95%CI: 0–16), p<0.001]. Urine MTB/RIF-generated CT values correlated poorly with markers of bacillary burden (smear grade and time-to-positivity). Conclusions/Significance This preliminary study indicates that urine-based MTB/RIF, alone or in combination with LAM antigen detection, may potentially aid the diagnosis of TB in HIV-infected patients with advanced immunosuppression when sputum-based diagnosis is not possible. Concentration of urine prior to MTB/RIF-testing significantly improves sensitivity. PMID:22815718

  3. Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system.

    PubMed

    Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan

    2017-12-15

    A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSD<3.1%, n=6) and good linearity in the range of 50-1000mgL -1 and 0.5-100mgL -1 , respectively. By this method, concentrations of GHB in the selected human urine samples were detected in the range of 0-1.57mgL -1 . The urine sample containing 0.89mgL -1 GHB was selected to evaluate the accuracy; the spiked recoveries of GHB were 95.9-102.8%. The results showed that the two-dimensional ion chromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Real-Time Polymerase Chain Reaction for Detection of Schistosoma DNA in Small-Volume Urine Samples Reflects Focal Distribution of Urogenital Schistosomiasis in Primary School Girls in KwaZulu Natal, South Africa

    PubMed Central

    Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette

    2014-01-01

    Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560

  5. Development of Technologies for Early Detection and Stratification of Breast Cancer

    DTIC Science & Technology

    2014-10-01

    cancer. Similar screening has been done in urine samples with CYR61 and LCN2 (Figure 2a-b). The Moses lab provided breast cancer urine samples and two ...diseased samples, while CYR61 appears to have two different populations whereas diseased urine samples have lower levels of the protein present. More... system for eDAR so that each isolated cell can be deposited into a well of a 96-well plate for high-throughput downstream single-cell digital

  6. DNA typing for personal identification of urine after long-term preservation for testing in doping control.

    PubMed

    Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto

    2017-08-01

    When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Immunoreactive LH in long-term frozen human urine samples.

    PubMed

    Singh, Gurmeet Kaur Surindar; Jimenez, Mark; Newman, Ron; Handelsman, David J

    2014-04-01

    Urine provides a convenient non-invasive alternative to blood sampling for measurement of certain hormones. Urinary luteinizing hormone (LH) measurements have been used for endocrinology research and anti-doping testing. However, the commercially available LH immunoassays are developed and validated for human blood samples but not urine so that LH assays intended for use with urine samples need thorough validation. Therefore, the present study evaluated the measurement of urinary LH immunoreactivity using previously validated immunofluorometric (IF) and immunochemiluminometric (ICL) LH assays after prolonged frozen storage. LH was measured in serial urine samples following administration of a single injection of one of two doses of recombinant human chorionic hormone (rhCG) with assays run at the end of study (2008) and again after four years of frozen (-20 °C) storage where samples were stored without adding preservatives. The ICL assay showed quantitatively reproducible LH measurements after prolonged -20 °C storage. However, the IF immunoassay gave consistently lower LH levels relative to ICL (2008) with a further proportionate reduction after four years of sample storage (2012). Yet, both the assays displayed similar patterns of the time-course of urine LH measurement both before and after four years of frozen storage. In conclusion, we found that both immunoassays are suitable for urinary LH measurements with ICL assay being more robust for quantitative urinary LH measurement such as for anti-doping purposes, whereas the IF could be applicable for research studies where urine LH levels are compared within-study but not in absolute terms. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Preparation of magnetic ODS-PAN thin-films for microextraction of quetiapine and clozapine in plasma and urine samples followed by HPLC-UV detection.

    PubMed

    Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan

    2016-06-05

    In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.

    PubMed

    Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O

    1996-01-01

    This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.

  10. Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe

    2007-01-01

    Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitablemore » sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.« less

  11. Optimizing Urine Processing Protocols for Protein and Metabolite Detection.

    PubMed

    Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K

    In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Healthy women provided multiple urine samples during the same day. Women collected their first morning (1 st AM) void and another "random void". Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Ten Caucasian women between 35-65 years of age provided paired 1 st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1 st AM compared to random "spot" voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4°C or RT storage temperature.

  12. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    PubMed

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD < 7%). Holding time studies in unpreserved urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  13. Diagnosis and effects of urine contamination in cooled-extended stallion semen.

    PubMed

    Ellerbrock, R; Canisso, I; Feijo, L; Lima, F; Shipley, C; Kline, K

    2016-04-15

    Urospermia is known to affect semen quality in many mammals, including stallions. Determinations of semen pH and creatinine and urea concentrations have been used to diagnose urine contamination in raw stallion semen. Unfortunately, practitioners suspecting urine contamination in cooled-shipped samples have no proven means to confirm the presence of urine. Therefore, the objectives of this study were (1) to assess the effects of urine contamination on sperm motility of extended fresh and cooled-stored stallion semen, (2) to evaluate the usefulness of semen color, odor, pH, and creatinine and urea concentrations for urospermia diagnosis, and (3) to evaluate the accuracy of a commercial blood urea nitrogen test strip in diagnosing urine contamination in extended-cooled stallion semen. Thirty-seven ejaculates were obtained from 11 stallions with no history of urospermia before division into 5 mL aliquots, and contamination with stallion urine. Each resulting sample was assessed for sperm motility, color, odor, pH, creatinine, and urea nitrogen concentration using both a semiquantitative test strip (Azostix), and a quantitative automated analyzer before and after cooling for 24 hour. Sperm motility parameters, pH, and creatinine and urea concentrations were analyzed using mixed models. Urine contamination decreased total and progressive motility in all samples before and after cooling (P < 0.05). Mean control total motility was 80% at 0 hour and 67% at 24 hours, whereas urine-contaminated samples ranged from 30% to 71% at 0 hour and 27% to 61% at 24 hours. Control mean urea (29 mg/dL) and creatinine (0.6 mg/dL) concentrations were significantly different (P < 0.05) from all urine-contaminated samples (158 mg/dL and 11.6 mg/dL, respectively) at 0 hour. Similarly, control mean urea (8 mg/dL) and creatinine (0.9 mg/dL) concentrations were significantly different than all urine-contaminated samples at 24 hours. Odor assessment presented moderate sensitivity (65%) and high specificity (100%), while color assessment presented low sensitivity (47%) and moderate specificity (79%) for urine in extended semen. Azostix strips were highly sensitive (95%) and specific (97%). Assessment of color, odor, and pH are not reliable methods to diagnose urine in experimentally contaminated cooled-stored stallion semen. Sperm motility parameters (in raw and cooled semen) are significantly reduced by the presence of urine in a concentration dependent. The results of the present study indicated that determination of urea and creatinine concentrations can be used to diagnose urospermia and that Azostix can be used as a point care method for diagnosing urine contamination in extended cooled stallion semen. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    PubMed

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  15. Fully automated methods for the determination of hydrochlorothiazide in human plasma and urine.

    PubMed

    Hsieh, J Y; Lin, C; Matuszewski, B K; Dobrinska, M R

    1994-12-01

    LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology Robot and BenchMate Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and on-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml-1 in plasma and 0.1-20 micrograms ml-1 in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.

  16. Combined quantification of paclitaxel, docetaxel and ritonavir in human feces and urine using LC-MS/MS.

    PubMed

    Hendrikx, Jeroen J M A; Rosing, Hilde; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2014-02-01

    A combined assay for the determination of paclitaxel, docetaxel and ritonavir in human feces and urine is described. The drugs were extracted from 200 μL urine or 50 mg feces followed by high-performance liquid chromatography analysis coupled with positive ionization electrospray tandem mass spectrometry. The validation program included calibration model, accuracy and precision, carry-over, dilution test, specificity and selectivity, matrix effect, recovery and stability. Acceptance criteria were according to US Food and Drug Administration guidelines on bioanalytical method validation. The validated range was 0.5-500 ng/mL for paclitaxel and docetaxel, 2-2000 ng/mL for ritonavir in urine, 2-2000 ng/mg for paclitaxel and docetaxel, and 8-8000 ng/mg for ritonavir in feces. Inter-assay accuracy and precision were tested for all analytes at four concentration levels and were within 8.5% and <10.2%, respectively, in both matrices. Recovery at three concentration levels was between 77 and 94% in feces samples and between 69 and 85% in urine samples. Method development, including feces homogenization and spiking blank urine samples, are discussed. We demonstrated that each of the applied drugs could be quantified successfully in urine and feces using the described assay. The method was successfully applied for quantification of the analytes in feces and urine samples of patients. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine.

    PubMed

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable.

  18. Comparison of Depletion Strategies for the Enrichment of Low-Abundance Proteins in Urine

    PubMed Central

    Filip, Szymon; Vougas, Konstantinos; Zoidakis, Jerome; Latosinska, Agnieszka; Mullen, William; Spasovski, Goce; Mischak, Harald; Vlahou, Antonia; Jankowski, Joachim

    2015-01-01

    Proteome analysis of complex biological samples for biomarker identification remains challenging, among others due to the extended range of protein concentrations. High-abundance proteins like albumin or IgG of plasma and urine, may interfere with the detection of potential disease biomarkers. Currently, several options are available for the depletion of abundant proteins in plasma. However, the applicability of these methods in urine has not been thoroughly investigated. In this study, we compared different, commercially available immunodepletion and ion-exchange based approaches on urine samples from both healthy subjects and CKD patients, for their reproducibility and efficiency in protein depletion. A starting urine volume of 500 μL was used to simulate conditions of a multi-institutional biomarker discovery study. All depletion approaches showed satisfactory reproducibility (n=5) in protein identification as well as protein abundance. Comparison of the depletion efficiency between the unfractionated and fractionated samples and the different depletion strategies, showed efficient depletion in all cases, with the exception of the ion-exchange kit. The depletion efficiency was found slightly higher in normal than in CKD samples and normal samples yielded more protein identifications than CKD samples when using both initial as well as corresponding depleted fractions. Along these lines, decrease in the amount of albumin and other targets as applicable, following depletion, was observed. Nevertheless, these depletion strategies did not yield a higher number of identifications in neither the urine from normal nor CKD patients. Collectively, when analyzing urine in the context of CKD biomarker identification, no added value of depletion strategies can be observed and analysis of unfractionated starting urine appears to be preferable. PMID:26208298

  19. Improved bacterial identification directly from urine samples with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Kitagawa, Koichi; Shigemura, Katsumi; Onuma, Ken-Ichiro; Nishida, Masako; Fujiwara, Mayu; Kobayashi, Saori; Yamasaki, Mika; Nakamura, Tatsuya; Yamamichi, Fukashi; Shirakawa, Toshiro; Tokimatsu, Issei; Fujisawa, Masato

    2018-03-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) contributes to rapid identification of pathogens in the clinic but has not yet performed especially well for Gram-positive cocci (GPC) causing complicated urinary tract infection (UTI). The goal of this study was to investigate the possible clinical use of MALDI-TOF MS as a rapid method for bacterial identification directly from urine in complicated UTI. MALDI-TOF MS was applied to urine samples gathered from 142 suspected complicated UTI patients in 2015-2017. We modified the standard procedure (Method 1) for sample preparation by adding an initial 10 minutes of ultrasonication followed by centrifugation at 500 g for 1 minutes to remove debris such as epithelial cells and leukocytes from the urine (Method 2). In 133 urine culture-positive bacteria, the rate of corresponded with urine culture in GPC by MALDI-TOF MS in urine with standard sample preparation (Method 1) was 16.7%, but the modified sample preparation (Method 2) significantly improved that rate to 52.2% (P=.045). Method 2 also improved the identification accuracy for Gram-negative rods (GNR) from 77.1% to 94.2% (P=.022). The modified Method 2 significantly improved the average MALDI score from 1.408±0.153 to 2.166±0.045 (P=.000) for GPC and slightly improved the score from 2.107±0.061 to 2.164±0.037 for GNR. The modified sample preparation for MALDI-TOF MS can improve identification accuracy for complicated UTI causative bacteria. This simple modification offers a rapid and accurate routine diagnosis for UTI, and may possibly be a substitute for urine cultures. © 2017 Wiley Periodicals, Inc.

  20. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Investigating Cortisol Production and Pattern as Mediators in the Relationship Between Shift Work and Cardiometabolic Risk.

    PubMed

    Ritonja, Jennifer; Aronson, Kristan J; Day, Andrew G; Korsiak, Jill; Tranmer, Joan

    2018-05-01

    Shift work is a risk factor for many diseases, including cardiovascular disease. Although the biological pathways are still unclear, it is hypothesized that cortisol disruption during night work is an intermediate. The objective of this study is to determine whether total cortisol production and cortisol pattern mediate the relationship between current shift work and cardiometabolic risk (CMR) among female hospital employees. A cross-sectional study was conducted among 326 female employees (166 rotating shift workers, 160 day workers), recruited from a hospital in Southeastern Ontario, Canada, during 2011 to 2014. Participants completed a baseline interview, questionnaire, and clinical exam. Urine samples were collected over two 24-hour periods and used to analyze creatinine-adjusted cortisol, which was then used to calculate total cortisol production (AUC G ), and pattern (AUC I ). Mediation analysis was performed to test the mediating effect of cortisol in the relationship between shift work and a continuous CMR score. Current shift work is associated with a 0.52 higher CMR score (95% CI: 0.15, 0.89), a lower cortisol output (AUC G ), and a flatter pattern (AUC I ) over a 2-day period. AUC G is a partial mediator in the relationship between shift work and CMR, whereas AUC I is not. AUC G is also associated with CMR while controlling for shift work, suggesting that lower total cortisol production is also linked to CMR in non-shift workers. Total cortisol production is a partial mediator in the relationship between rotating shift work and CMR among female hospital employees, whereas cortisol pattern is not a mediator. Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  2. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  3. Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Salgado-Petinal, Carmen; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2005-07-01

    In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.

  4. Surveying Mercury Levels in Hair, Blood and Urine of under 7-Year Old Children from a Coastal City in China

    PubMed Central

    Chen, Guixia; Chen, Xiaoxin; Yan, Chonghuai; Wu, Xingdong; Zeng, Guozhang

    2014-01-01

    Aim: The average mercury load in children under 7-years old was determined in a populated but not overly industrial coastal area in China. Methods: 395 blood samples, 1072 urine samples, and 581 hair samples were collected from 1076 children, aged 0 to 6 years, from eight representative communities of Xiamen, China. Mercury levels in the samples were surveyed. Results: The 95% upper limits of mercury in blood, urine, and hair for the children were 2.30, 1.50 and 2100.00 μg/kg, respectively. Levels tended to increase with age. Correlation analyses showed that mercury levels in blood and urine correlated with those in hair (n = 132), r = 0.49, p < 0.0001 and r = 0.20, p = 0.0008; however, blood mercury levels did not correlate with urine levels (n = 284), r = 0.07, p = 0.35. Conclusions: Surveying the average mercury load in children 0 to 6 years, and the 95% upper limit value of mercury in their blood, urine, and hair should help guide risk assessment and health management for children. PMID:25419876

  5. Major Odorants Released as Urinary Volatiles by Urinary Incontinent Patients

    PubMed Central

    Pandey, Sudhir Kumar; Kim, Ki-Hyun; Choi, Si On; Sa, In Young; Oh, Soo Yeon

    2013-01-01

    In this study, volatile urinary components were collected using three different types of samples from patients suffering from urinary incontinence (UI): (1) urine (A); (2) urine + non-used pad (B); and (3) urine + used pad (C). In addition, urine + non-used pad (D) samples from non-patients were also collected as a reference. The collection of urinary volatiles was conducted with the aid of a glass impinger-based mini-chamber method. Each of the four sample types (A through D) was placed in a glass impinger and incubated for 4 hours at 37 °C. Ultra pure air was then passed through the chamber, and volatile urine gas components were collected into Tedlar bags at the other end. These bag samples were then analyzed for a wide range of VOCs and major offensive odorants (e.g., reduced sulfur compounds (RSCs), carbonyls, trimethylamine (TMA), ammonia, etc.). Among the various odorants, sulfur compounds (methanethiol and hydrogen sulfide) and aldehydes (acetaldehyde, butylaldehyde, and isovaleraldehyde) were detected above odor threshold and predicted to contribute most effectively to odor intensity of urine incontinence. PMID:23823973

  6. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  7. ECLSS Sustaining Compatibility Testing on Urine Processor Assembly Nonmetallic Materials for Reformulation of Pretreated Urine Solution

    NASA Technical Reports Server (NTRS)

    Wingard, C. D.

    2015-01-01

    On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.

  8. Flow meter urine testing: a practical proposition in patients attending for urodynamics?

    PubMed

    Hashim, Hashim; Abrams, Paul

    2006-05-01

    To find a practical way of detecting urinary tract infection (UTI) before invasive urodynamic testing, as UTIs after urodynamics are well documented, but there are no standard guidelines about when urine should be analysed before urodynamics. Before urodynamics all patients are asked to provide a free urine flow; the patient is then catheterized to obtain a catheter-specimen of urine that is tested for infection by a urine dipstick. If the dipstick is found positive for nitrites and/or leukocytes, the test is abandoned and the sample sent for microscopy, culture and sensitivity. In the present study, patients were asked to provide a free urine flow into the flowmeter as usual. Between patients, the flowmeter was washed with soap and water and dried, so that there would be no cross-contamination between patients' urine results. Urine was collected as usual and tested using a dipstick, the patient was then catheterized and another dipstick test done on the catheter specimen of urine (CSU), to compare results. Pairs of urine samples, when positive for nitrite were 100% consistent, and 89% of pairs positive for leukocytes were the same before and after catheterization. The remaining 11% (all women) of the positive leukocyte group had leukocytosis on testing the flowmeter urine but not on the CSU, possibly due to contamination from the vagina. Testing urine by dipstick in the sample from the flowmeter is a feasible option, thus saving the patient an inappropriate catheterization, with the risk of bacteraemia during urodynamics, and allowing the flowrate to be measured.

  9. Reproducibility of urinary biomarkers in multiple 24-h urine samples.

    PubMed

    Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C

    2017-01-01

    Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses' Health Study), NHSII (Nurses' Health Study II), and Health Professionals Follow-Up Study. In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. © 2017 American Society for Nutrition.

  10. Reproducibility of urinary biomarkers in multiple 24-h urine samples123

    PubMed Central

    Sun, Qi; Bertrand, Kimberly A; Franke, Adrian A; Rosner, Bernard; Curhan, Gary C; Willett, Walter C

    2017-01-01

    Background: Limited knowledge regarding the reproducibility of biomarkers in 24-h urine samples has hindered the collection and use of the samples in epidemiologic studies. Objective: We aimed to evaluate the reproducibility of various markers in repeat 24-h urine samples. Design: We calculated intraclass correlation coefficients (ICCs) of biomarkers measured in 24-h urine samples that were collected in 3168 participants in the NHS (Nurses’ Health Study), NHSII (Nurses’ Health Study II), and Health Professionals Follow-Up Study. Results: In 742 women with 4 samples each collected over the course of 1 y, ICCs for sodium were 0.32 in the NHS and 0.34 in the NHSII. In 2439 men and women with 2 samples each collected over 1 wk to ≥1 mo, the ICCs ranged from 0.33 to 0.68 for sodium at various intervals between collections. The urinary excretion of potassium, calcium, magnesium, phosphate, sulfate, and other urinary markers showed generally higher reproducibility (ICCs >0.4). In 47 women with two 24-h urine samples, ICCs ranged from 0.15 (catechin) to 0.75 (enterolactone) for polyphenol metabolites. For phthalates, ICCs were generally ≤0.26 except for monobenzyl phthalate (ICC: 0.55), whereas the ICC was 0.39 for bisphenol A (BPA). We further estimated that, for the large majority of the biomarkers, the mean of three 24-h urine samples could provide a correlation of ≥0.8 with true long-term urinary excretion. Conclusions: These data suggest that the urinary excretion of various biomarkers, such as minerals, electrolytes, most polyphenols, and BPA, is reasonably reproducible in 24-h urine samples that are collected within a few days or ≤1 y. Our findings show that three 24-h samples are sufficient for the measurement of long-term exposure status in epidemiologic studies. PMID:28049663

  11. Preoperative Bladder Urine Culture as a Predictor of Intraoperative Stone Culture Results: Clinical Implications and Relationship to Stone Composition

    PubMed Central

    Paonessa, Jessica E.; Gnessin, Ehud; Bhojani, Naeem; Williams, James C.; Lingeman, James E.

    2018-01-01

    Purpose We examine the relationship between urine and stone cultures in a large cohort of patients undergoing percutaneous stone removal and compare the findings in infectious vs metabolic calculi. Materials and Methods A total of 776 patients treated with percutaneous nephrolithotomy who had preoperative urine cultures and intraoperative stone cultures were included in the study. Statistical analysis used chi-square or logistic fit analysis as appropriate. Results Preoperative urine culture was positive in 352 patients (45.4%) and stone cultures were positive in 300 patients (38.7%). There were 75 patients (9.7%) with negative preoperative cultures who had positive stone cultures, and in patients with both cultures positive the organisms differed in 103 (13.3%). Gram-positive organisms predominated in preoperative urine and stone cultures. Conclusions Preoperative urine cultures in patients undergoing percutaneous nephrolithotomy are unreliable as there is a discordance with intraoperative stone cultures in almost a quarter of cases. There has been a notable shift toward gram-positive organisms in this cohort of patients. PMID:27038771

  12. The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings.

    PubMed

    Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh

    2016-01-01

    Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

  13. A study examining the bias of albumin and albumin/creatinine ratio measurements in urine.

    PubMed

    Jacobson, Beryl E; Seccombe, David W; Katayev, Alex; Levin, Adeera

    2015-10-01

    The objective of the study was to examine the bias of albumin and albumin/creatinine (ACR) measurements in urine. Pools of normal human urine were augmented with purified human serum albumin to generate a series of 12 samples covering the clinical range of interest for the measurement of ACR. Albumin and creatinine concentrations in these samples were analyzed three times on each of 3 days by 24 accredited laboratories in Canada and the USA. Reference values (RV) for albumin measurements were assigned by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) comparative method and gravimetrically. Ten random urine samples (check samples) were analyzed as singlets and albumin and ACR values reported according to the routine practices of each laboratory. Augmented urine pools were shown to be commutable. Gravimetrically assigned target values were corrected for the presence of endogenous albumin using the LC-MS/MS comparative method. There was excellent agreement between the RVs as assigned by these two methods. All laboratory medians demonstrated a negative bias for the measurement of albumin in urine over the concentration range examined. The magnitude of this bias tended to decrease with increasing albumin concentrations. At baseline, only 10% of the patient ACR values met a performance limit of RV ± 15%. This increased to 84% and 86% following post-analytical correction for albumin and creatinine calibration bias, respectively. International organizations should take a leading role in the standardization of albumin measurements in urine. In the interim, accuracy based urine quality control samples may be used by clinical laboratories for monitoring the accuracy of their urinary albumin measurements.

  14. Analytical precision of the Urolizer for the determination of the BONN-Risk-Index (BRI) for calcium oxalate urolithiasis and evaluation of the influence of 24-h urine storage at moderate temperatures on BRI.

    PubMed

    Berg, Wolfgang; Bechler, Robin; Laube, Norbert

    2009-01-01

    Since its first publication in 2000, the BONN-Risk-Index (BRI) has been successfully used to determine the calcium oxalate (CaOx) crystallization risk from urine samples. To date, a BRI-measuring device, the "Urolizer", has been developed, operating automatically and requiring only a minimum of preparation. Two major objectives were pursued: determination of Urolizer precision, and determination of the influence of 24-h urine storage at moderate temperatures on BRI. 24-h urine samples from 52 CaOx stone-formers were collected. A total of 37 urine samples were used for the investigation of Urolizer precision by performing six independent BRI determinations in series. In total, 30 samples were taken for additional investigation of urine storability. Each sample was measured thrice: directly after collection, after 24-h storage at T=21 degrees C, and after 24-h cooling at T=4 degrees C. Outcomes were statistically tested for identity with regard to the immediately obtained results. Repeat measurements for evaluation of Urolizer precision revealed statistical identity of data (p-0.05). 24-h storage of urine at both tested temperatures did not significantly affect BRI (p-0.05). The pilot-run Urolizer shows high analytical reliability. The innovative analysis device may be especially suited for urologists specializing in urolithiasis treatment. The possibility for urine storage at moderate temperatures without loss of analysis quality further demonstrates the applicability of the BRI method.

  15. Mining the human urine proteome for monitoring renal transplant injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; Gao, Yuqian; He, Jintang

    The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used inmore » the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.« less

  16. Source-separated urine opens golden opportunities for microbial electrochemical technologies.

    PubMed

    Ledezma, Pablo; Kuntke, Philipp; Buisman, Cees J N; Keller, Jürg; Freguia, Stefano

    2015-04-01

    The food security of a booming global population demands a continuous and sustainable supply of fertilisers. Their current once-through use [especially of the macronutrients nitrogen (N), phosphorus (P), and potassium (K)] requires a paradigm shift towards recovery and reuse. In the case of source-separated urine, efficient recovery could supply 20% of current macronutrient usage and remove 50-80% of nutrients present in wastewater. However, suitable technology options are needed to allow nutrients to be separated from urine close to the source. Thus far none of the proposed solutions has been widely implemented due to intrinsic limitations. Microbial electrochemical technologies (METs) have proved to be technically and economically viable for N recovery from urine, opening the path for novel decentralised systems focused on nutrient recovery and reuse. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Comparison of Uriswab to alternative methods for urine culture collection and transport: confirmation of standard culture methodology for investigation of urinary tract infections.

    PubMed

    Rennie, Robert P; Turnbull, Lee-Ann; Gauchier-Pitts, Kaylee; Bennett, Tracy; Dyrland, Debbie; Blonski, Susan

    2016-08-01

    The ability to isolate and identify causative agents of urinary tract infections relies primarily on the quality of the urine sample that is submitted to the microbiology. The most important factors are the method of collection, the maintenance of viability of the potential pathogens during transport, and standardization of the culturing of the urine sample. This report is a composite of several investigations comparing collection and transport on urine culture paddles, with a preservative urine sponge (Uriswab), and a comparison of Uriswab with the BD preservative transport tube as methods of preservation of urinary pathogens. Primary studies showed that Uriswab maintained significantly more urinary pathogens than the urine culture paddle with fewer mixed or contaminated cultures. The two preservative transport systems were comparable for maintenance of viability of the pathogens, but there were fewer mixed cultures when samples were collected with Uriswab. This study confirms the importance of a standard volume of 1 μL of urine for culture. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Heat stress, dehydration, and kidney function in sugarcane cutters in El Salvador--A cross-shift study of workers at risk of Mesoamerican nephropathy.

    PubMed

    García-Trabanino, Ramón; Jarquín, Emmanuel; Wesseling, Catharina; Johnson, Richard J; González-Quiroz, Marvin; Weiss, Ilana; Glaser, Jason; José Vindell, Juan; Stockfelt, Leo; Roncal, Carlos; Harra, Tamara; Barregard, Lars

    2015-10-01

    An epidemic of progressive kidney failure afflicts sugarcane workers in Central America. Repeated high-intensity work in hot environments is a possible cause. To assess heat stress, dehydration, biomarkers of renal function and their possible associations. A secondary aim was to evaluate the prevalence of pre-shift renal damage and possible causal factors. Sugarcane cutters (N=189, aged 18-49 years, 168 of them male) from three regions in El Salvador were examined before and after shift. Cross-shift changes in markers of dehydration and renal function were examined and associations with temperature, work time, region, and fluid intake were assessed. Pre-shift glomerular filtration rate was estimated (eGFR) from serum creatinine. The mean work-time was 4 (1.4-11) hours. Mean workday temperature was 34-36 °C before noon, and 39-42 °C at noon. The mean liquid intake during work was 0.8L per hour. There were statistically significant changes across shift. The mean urine specific gravity, urine osmolality and creatinine increased, and urinary pH decreased. Serum creatinine, uric acid and urea nitrogen increased, while chloride and potassium decreased. Pre-shift serum uric acid levels were remarkably high and pre-shift eGFR was reduced (<60 mL/min) in 23 male workers (14%). The high prevalence of reduced eGFR, and the cross-shift changes are consistent with recurrent dehydration from strenuous work in a hot and humid environment as an important causal factor. The pathophysiology may include decreased renal blood flow, high demands on tubular reabsorption, and increased levels of uric acid. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Excretion profile of boldenone in urine of veal calves fed two different milk replacers.

    PubMed

    Draisci, R; Merlanti, R; Ferretti, G; Fantozzi, L; Ferranti, C; Capolongo, F; Segato, S; Montesissa, C

    2007-03-14

    The residue profiles of 17alpha-/17beta-boldenone conjugated (17alpha/beta-Bol) and ADD were investigated by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in urine of male veal calves fed two commercial milk replacers, with different content of cholesterol and phytosterols. The urine samples were collected within 4 h after feeding and further from all the animals. Detectable amounts of 17alpha-Bol conjugated were measured in urine collected from all calves, but the concentrations of 17alpha-Bol were higher in urine from calves receiving the milk replacer with the greater amount of phytosterols. During the whole experiment, 17beta-Bol and ADD were never detected in urine samples collected.

  20. Sample handling for mass spectrometric proteomic investigations of human urine.

    PubMed

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HUMAN BIOLOGICAL MARKERS:BLOOD AND URINE SAMPLE COLLECTION AND ANALYSES (EOHSI-AP-209-040)

    EPA Science Inventory

    This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...

  2. Performance of Copan WASP for Routine Urine Microbiology

    PubMed Central

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  3. Comparison of sodium, potassium, calcium, magnesium, zinc, copper and iron concentrations of elements in 24-h urine and spot urine in hypertensive patients with healthy renal function.

    PubMed

    Zhang, Tianjing; Chang, Xiaoyu; Liu, Wanlu; Li, Xiaoxia; Wang, Faxuan; Huang, Liping; Liao, Sha; Liu, Xiuying; Zhang, Yuhong; Zhao, Yi

    2017-12-01

    Sodium, potassium, calcium, magnesium, zinc, copper and iron are associated with the sequela of hypertension. The most reliable method for testing those elements is by collecting 24-h urine samples. However, this is cumbersome and collection of spot urine is more convenient in some circumstance. The aim of this study was to compare the concentrations of different elements in 24-h urine and spot urine. Data was collected from a sub-study of China Salt Substitute and Stroke Study. 240 participants were recruited randomly from 12 villages in two counties in Ningxia, China. Both spot and 24-h urine specimens were collected from each patient. Routine urine test was conducted, and concentration of elements was measured using microwave digestion and Inductively Coupled Plasma-Optical Emission Spectrometry. Partial correlation analysis and Spearman correlation analysis were used to investigate the concentration of different elements and the relationship between 24- h urine and spot urine. A partial correlation in sodium, potassium, calcium, magnesium and iron was found between paired 24-h urine and spot urine samples except copper and zinc: 0.430, 0.426, 0.550, 0.221 and 0.191 respectively. Spot urine can replace 24-h urine for estimating some of the elements in hypertensive patients with normal renal function. Copyright © 2017 Elsevier GmbH. All rights reserved.

  4. Evaluation of equine urine reactivity towards phase II metabolites of 17-hydroxy steroids by liquid chromatography/tandem mass spectrometry.

    PubMed

    Fidani, M; Gamberini, M C; Pasello, E; Palazzoli, F; De Iuliis, P; Montana, M; Arioli, F

    2009-01-01

    Proper storage conditions of biological samples are fundamental to avoid microbiological contamination that can cause chemical modifications of the target analytes. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method through direct injection of diluted samples, without prior extraction, was used to evaluate the stability of phase II metabolites of boldenone and testosterone (glucuronides and sulphates) in intentionally poorly stored equine urine samples. We also considered the stability of some deuterated conjugated steroids generally used as internal standards, such as deuterated testosterone and epitestosterone glucuronides, and deuterated boldenone and testosterone sulphates. The urines were kept for 1 day at room temperature, to mimic poor storage conditions, then spiked with the above steroids and kept at different temperatures (-18 degrees C, 4 degrees C, room temperature). It has been possible to confirm the instability of glucuronide compounds when added to poorly stored equine urine samples. In particular, both 17beta- and 17alpha-glucuronide steroids were exposed to hydrolysis leading to non-conjugated steroids. Only 17beta-hydroxy steroids were exposed to oxidation to their keto derivatives whereas the 17alpha-hydroxy steroids were highly stable. The sulphate compounds were completely stable. The deuterated compounds underwent the same behaviour as the unlabelled compounds. The transformations were observed in urine samples kept at room temperature and at a temperature of 4 degrees C (at a slower rate). No modifications were observed in frozen urine samples. In the light of the latter results, the immediate freezing at -18 degrees C of the collected samples and their instant analysis after thawing is the proposed procedure for preventing the transformations that occur in urine, usually due to microbiological contamination. (c) 2008 John Wiley & Sons, Ltd.

  5. [An investigation of lanthanum and other metals levels in blood, urine and hair among residents in the rare earth mining area of a city in China].

    PubMed

    Bao, T M; Tian, Y; Wang, L X; Wu, T; Lu, L N; Ma, H Y; Wang, L

    2018-02-20

    Objective: To investigate the levels of lanthanum, cerium, praseodymium, and neodymium in the blood, urine, and hair samples from residents in the rare earth mining area of a city in China, and to provide a scientific basis for the control of rare earth pollution and the protection of population health. Methods: A total of 147 residents who had lived in the rare earth mining area of a city for a long time were selected as the exposure group, and 108 residents in Guyang County of this city who lived 91 km away from the rare earth mining area were selected as the control group. Blood, urine, and hair samples were collected from the residents in both groups. Inductively coupled plasma mass spectrometry was used to determine the content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair samples. Results: In the exposure group, the median levels of lanthanum, cerium, praseodymium, and neodymium were 0.854, 1.724, 0.132, and 0.839 μg/L, respectively, in blood samples, 0.420, 0.920, 0.055, and 0.337 μg/L, respectively, in urine samples, and 0.052, 0.106, 0.012, and 0.045 μg/g, respectively, in hair samples. The exposure group had significantly higher levels of the four rare earth elements in blood, urine, and hair samples than the control group ( P <0.01) . Conclusion: The residents in the rare earth mining area of this city have higher content of lanthanum, cerium, praseodymium, and neodymium in blood, urine, and hair than those in the non-mining area; the content of cerium is highest, followed by lanthanum, neodymium, and praseodymium.

  6. Temporal variability of pyrethroid metabolite levels in bedtime, morning, and 24-h urine samples for 50 adults in North Carolina.

    PubMed

    Morgan, Marsha K; Sobus, Jon R; Barr, Dana Boyd; Croghan, Carry W; Chen, Fu-Lin; Walker, Richard; Alston, Lillian; Andersen, Erik; Clifton, Matthew S

    2016-01-01

    Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study design and sampling methodology for the Pilot Study to Estimate Human Exposures to Pyrethroids using an Exposure Reconstruction Approach (Ex-R study). Two major objectives were to quantify the concentrations of several pyrethroid metabolites in bedtime, first morning void (FMV), and 24-h urine samples as concentration (wet weight), specific-gravity (SG) corrected, creatinine (CR) corrected, and excretion rate values for 50 Ex-R adults over a six-week monitoring period and to determine if these correction approaches for urine dilution reduced the variability of the biomarker levels. The Ex-R study was conducted at the United States Environmental Protection Agency's Human Studies Facility in Chapel Hill, North Carolina USA and at participants' homes within a 40-mile radius of this facility. Recruitment of participants and field activities occurred between October 2009 and May 2011. Participants, ages 19-50 years old, provided daily food, activity, and pesticide-use diaries and collected their own urine samples (bedtime, FMV, and 24-h) during weeks 1, 2, and 6 of a six-week monitoring period. A total of 2503 urine samples were collected from the study participants. These samples were analyzed for the pyrethroid metabolites 3-phenoxybenzoic acid (3-PBA), cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-cyclopropane carboxylic acid (cis/trans-DCCA), and 2-methyl-3-phenylbenzoic acid (MPA) using high performance liquid chromatography/tandem mass spectrometry. Only 3-PBA was frequently detected (>50%) in the adult urine samples. Median urinary 3-PBA levels were 0.88 ng/mL, 0.96 ng/mL-SG, 1.04 ng/mg, and 1.04 ng/min for concentration, SG-corrected, CR-corrected, and excretion rate values, respectively, across all urine samples. The results showed that median urinary 3-PBA concentrations were consistently the lowest in FMV samples (0.77 ng/mL, 0.68 ng/mL-SG, 0.68 ng/mg, and 0.58 ng/min) and the highest in 24-h samples (0.92 ng/mL, 1.06 ng/mL-SG, 1.18 ng/mg, and 1.19 ng/min) across all four methods. Intraclass correlation coefficient (ICC) estimates for 3-PBA indicated poor reproducibility (<0.22) for all urine sample types and methods over a day, week, and six weeks. Correcting for urine sample dilution, based on either SG, CR or urine output, introduced additional measurement variability both between- and within-individuals. These results indicate that a single measure of urinary 3-PBA was not sufficient to characterize average exposure regardless of sample type, correction method, and time frame of collection. In addition, the study results can be used to inform the design of exposure characterization strategies in relevant environmental epidemiology studies in the future. Published by Elsevier Inc.

  7. Simultaneous and confirmative detection of multi-residues of β₂-agonists and β-blockers in urine using LC-MS/MS/MS coupled with β-receptor molecular imprinted polymer SPE clean-up.

    PubMed

    Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N

    2013-01-01

    A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.

  8. Impact of urine preservation methods and duration of storage on measured levels of environmental contaminants.

    PubMed

    Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S

    2006-01-01

    Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.

  9. Quantitative analysis of zopiclone, N-desmethylzopiclone, zopiclone N-oxide and 2-amino-5-chloropyridine in urine using LC-MS-MS.

    PubMed

    Nilsson, Gunnel H; Kugelberg, Fredrik C; Ahlner, Johan; Kronstrand, Robert

    2014-01-01

    A simple liquid chromatography-tandem mass spectrometry method was validated to allow determination of zopiclone (ZOP), N-desmethylzopiclone (NDZOP), zopiclone N-oxide (ZOPNO) and 2-amino-5-chloropyridine (ACP) in urine at concentrations up to 3,000 ng/mL within 3.5 min. This method was used for quantitative analysis of the analytes in authentic urine samples obtained 10 h after oral administration of zopiclone (Imovane(®)) and in aliquots of the same urine samples after different storage conditions. In addition, pH of each studied urine sample was measured over time. The results showed that formation of ACP occurred at elevated pH and/or temperature by degradation of ZOP, NDZOP and ZOPNO. This method was also applied to samples obtained from two female victims of drug-facilitated assault. One sample had been exposed to long-term storage conditions at different temperatures and at pH >8.2, which resulted in high concentrations of ACP. The other sample, which was exposed to pH <6.5, showed no formation of ACP. ACP is formed both from ZOP and from its metabolites NDZOP and ZOPNO depending on the pH of the urine, time of storage and/or the temperature conditions. For correct interpretation in forensic cases, ZOP, its major metabolites and ACP should be analyzed. When ACP is identified in urine, the concentrations of ZOP, NDZOP and ZOPNO should be interpreted with great caution. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Feasibility of collecting 24-h urine to monitor sodium intake in the National Health and Nutrition Examination Survey123

    PubMed Central

    Terry, Ana L; Cogswell, Mary E; Wang, Chia-Yih; Chen, Te-Ching; Loria, Catherine M; Wright, Jacqueline D; Zhang, Xinli; Lacher, David A; Merritt, Robert K; Bowman, Barbara A

    2016-01-01

    Background: Twenty-four–hour urine sodium excretion is recommended for monitoring population sodium intake. Because of concerns about participation and completion, sodium excretion has not been collected previously in US nationally representative surveys. Objective: We assessed the feasibility of implementing 24-h urine collections as part of a nationally representative survey. Design: We selected a random half sample of nonpregnant US adults aged 20–69 y in 3 geographic locations of the 2013 NHANES. Participants received explicit instructions, started and ended the urine collection in a urine study mobile examination center, and answered questions about their collection. Among those with a complete 24-h urine collection, a random one-half were asked to collect a second 24-h urine sample. Sodium, potassium, chloride, and creatinine excretion were analyzed. Results: The final NHANES examination response rate for adults aged 20–69 y in these 3 study locations was 71%. Of those examined (n = 476), 282 (59%) were randomly selected to participate in the 24-h urine collection. Of these, 212 persons [75% of those selected for 24-h urine collection; 53% (equal to 71% × 75% of those selected for the NHANES)] collected a complete initial 24-h specimen and 92 persons (85% of 108 selected) collected a second complete 24-h urine sample. More men than women completed an initial collection (P = 0.04); otherwise, completion did not vary by sociodemographic characteristics, body mass index, education, or employment status for either collection. Mean 24-h urine volume and sodium excretion were 1964 ± 1228 mL and 3657 ± 2003 mg, respectively, for the first 24-h urine sample, and 2048 ± 1288 mL and 3773 ± 1891 mg, respectively, for the second collection. Conclusion: Given the 53% final component response rate and 75% completion rate, 24-h urine collections were deemed feasible and implemented in the NHANES 2014 on a subsample of adults aged 20–69 y to assess population sodium intake. This study was registered at clinicaltrials.gov as NCT02723682. PMID:27413136

  11. The influence of freezer storage of urine samples on the BONN-Risk-Index for calcium oxalate crystallization.

    PubMed

    Laube, Norbert; Zimmermann, Diana J

    2004-01-01

    This study was performed to quantify the effect of a 1-week freezer storage of urine on its calcium oxalate crystallization risk. Calcium oxalate is the most common urinary stone material observed in urolithiasis patients in western and affluent countries. The BONN-Risk-Index of calcium oxalate crystallization risk in human urine is determined from a crystallization experiment performed on untreated native urine samples. We tested the influence of a 1-week freezing on the BONN-Risk-Index value as well as the effect of the sample freezing on the urinary osmolality. In vitro crystallization experiments in 49 native urine samples from stone-forming and non-stone forming individuals were performed in order to determine their calcium oxalate crystallization risk according to the BONN-Risk-Index approach. Comparison of the results derived from original sample investigations with those obtained from the thawed aliquots by statistical evaluation shows that i) no significant deviation from linearity between both results exists and ii) both results are identical by statistical means. This is valid for both, the BONN-Risk-Index and the osmolality data. The differences in the BONN-Risk-Index results of both procedures of BONN-Risk-Index determination, however, exceed the clinically acceptable difference. Thus, determination of the urinary calcium oxalate crystallization risk from thawed urine samples cannot be recommended.

  12. Artificial Urine for Teaching Urinalysis Concepts and Diagnosis of Urinary Tract Infection in the Medical Microbiology Laboratory.

    PubMed

    Khan, Latifa B; Read, Hannah M; Ritchie, Stephen R; Proft, Thomas

    2017-01-01

    Dipstick urinalysis is an informative, quick, cost-effective and non-invasive diagnostic tool that is useful in clinical practice for the diagnosis of urinary tract infections (UTIs), kidney diseases, and diabetes. We used dipstick urinalysis as a hands-on microbiology laboratory exercise to reinforce student learning about UTIs with a particular focus on cystitis, which is a common bacterial infection. To avoid exposure to potentially contaminated human urine samples, we prepared artificial urine using easily acquired and affordable ingredients, which allowed less-experienced students to perform urinalysis without the risk of exposure to pathogenic organisms and ensured reliable availability of the urine samples. This practical class taught medical students how to use urinalysis data in conjunction with medical history to diagnose diseases from urine samples and to determine a treatment plan for clinical scenarios.

  13. Isolation of infectious Zika virus from a urine sample cultured in SIRC cells from a patient suspected of having rubella virus.

    PubMed

    Oliveira, Maria Isabel de; Namiyama, Gislene Mitsue; Cabral, Gabriela Bastos; Ferreira, João Leandro; Taniwaki, Noemi; Afonso, Ana Maria Sardinha; Lima, Isabella Rillo; Brigido, Luís Fernando Macedo de

    2018-01-01

    A great variety of viruses which cause exanthema share other clinical manifestations, making the etiologic identification a very difficult task, relying exclusively on the clinical examination. Rubella virus (RV) infection during the early stages of pregnancy can lead to serious birth defects, known as congenital rubella syndrome (CRS). In the present report, we described the presence of Zika virus (ZIKV) particles in urine samples and also ZIKV isolation in SIRC cells from the urine of a patient in acute phase of suspected rubella disease. The 50-year-old unvaccinated woman living in Sao Paulo, Brazil, was admitted to the emergency room with fever, headache, rash, arthralgia and prostration. Urine samples were collected for virus isolation and RT-qPCR. SIRC and Vero cells were inoculated with urine samples during 7 days. RT-qPCR was performed using measles virus (MV) and RV primers and both were found to be negative. After this result, RT-qPCR was performed for parvovirus B19, herpes virus 6 and ZIKV. The urine sample and the isolate were positive by Real Time PCR for ZIKV and negative for all other viruses tested. The sequences isolated are from the Asiatic lineage.

  14. [The role of telomerase activity in non-invasive diagnostics of bladder cancer].

    PubMed

    Glybochko, P V; Alyaev, J G; Potoldykova, N V; Polyakovsky, K A; Vinarov, A Z; Glukhov, A I; Gordeev, S A

    2016-08-01

    To evaluate the potentials of determining the telomerase activity (TA) in the cellular material of the urine for noninvasive diagnosis of bladder cancer (BC). Evaluation of TA was performed in the urine of 48 patients with bladder cancer (study group) before and after transurethral resection of the bladder wall (n=38), an open resection of the bladder (n=4), and cystectomy (n=6). TA was also evaluated in 48 tumor tissue samples obtained from these patients during removal of the bladder tumor. Each sample of the tumor tissue was separated into two parts, one of which was subjected to histological examination, and the latter was used to determine the telomerase activity. In all cases, the diagnosis of bladder cancer was confirmed morphologically. Determination of TA in the samples was performed by the modified TRAP-method (telomerase repeat amplification protocol), RT-PCR, PCR, and electrophoresis. As a control, cell material of the urine and tissue in 12 patients with chronic cystitis was investigated. TA before surgery was found in 45 (93.75%) of 48 samples of cellular material of the urine from patients with suspected bladder cancer. BC was histologically verified in all patients in this group. In the postoperative period, TA was not observed in the 48 samples of cellular material of the urine from patients with BC. In the control group of patients with histologically verified cystitis, weak TA was determined only in one sample of cellular material of the urine. The analysis indicates statistically significant predominance of patients with bladder cancer in case of TA in the urine (P=0.001). TA was detected in all samples of tumor tissue. We also analyzed the dependence of TA levels in urine and tissue on the degree of BC differentiation. In patients with highly differentiated BC, mean AT in the cellular materials of the urine was 0,61% (n=15), in patients with moderately differentiated BC - 0.95% (n=23), in patients with low-grade bladder cancer - 1.33% (n=10); in other words, increase in the TA levels with decreasing the degree of differentiation was observed. This finding can be used in the prognosis of the course of disease based on determining the TA level in these patients. Preliminary data indicate the possibility of use of determining the TA in cellular material of the urine for the diagnosis and monitoring of bladder cancer recurrence.

  15. Urine Collected From Diapers Can Be Used for 2-Dimensional Polyacrylamide Gel Electrophoresis (2D-PAGE) in Infants and Young Children

    PubMed Central

    Kennedy, Mary Jayne; Griffin, Angela; Su, Ruifeng; Merchant, Michael; Klein, Jon

    2011-01-01

    Urinary proteomic profiling has potential to identify candidate biomarkers of renal injury in infants provided an adequate urine sample can be obtained. Although diapers are used to obtain urine for clinical evaluation, their use for proteomic analysis has not been investigated. We therefore performed feasibility studies on the use of diaper-extracted urine for 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Pediatric waste urine (2–20 mL) was applied to gel-containing, non-gel and cotton-gauze diapers and then mechanically expressed. Urine volume and total protein were measured pre- and post-extraction. Proteins were separated via 2D-PAGE following application of urine (20–40 mL) to each matrix. 2D-PAGE was also performed on clinical specimens collected using each diaper type. Differences in the adsorption and retention of urine volume and protein were noted between matrices. Non-gel and cotton-gauze diapers provided the best protein/volume recovery and the lowest interference with the Bradford assay. 2D-PAGE was also successfully completed using urine samples from both cotton fiber matrices. Conversely, samples from low-gel diapers demonstrated poor protein separation and reproducibility. Diapers containing cotton-fiber matrices appear adequate for 2D-PAGE. Qualitative and quantitative analyses of resolved proteins using replicate, high resolution gels will be required, however, before diaper-extracted urine can be applied in proteomic profiling. PMID:21137001

  16. Direct Analysis of Amphetamine Stimulants in a Whole Urine Sample by Atmospheric Solids Analysis Probe Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.

    2016-05-01

    Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.

  17. Workplace drug testing in Italy: findings about second-stage testing.

    PubMed

    Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo

    2015-03-01

    Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.

  18. The consequence of delayed fixation on subsequent preservation of urine cells.

    PubMed

    Ahmed, Hussain G; Tom, Murtada Am

    2011-01-01

    Degenerative changes caused by delays in urine preservation contribute to false-negative and false-positive interpretation of urothelial disease in cytology. The aim of this study is to assess whether the delay of fixation of urine samples makes any significant difference to urine cytology and morphology, and the limit of acceptability of delay for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analyzing the preservation and degeneration of cells in urine samples. In this study, 50 voided urine specimens were taken at random from females complaining of vaginal discharge. Each specimen was divided into three sterile containers. The first was immediately centrifugated and the deposit was smeared onto a cleaned micro slide and immediately fixed into 95% ethyl alcohol for 15 minutes. The remaining two were prepared in the same manner, however, the second after two hours of collection and the third after four hours of collection. The degree of degeneration and thus the preservation were assessed by a table of chosen criteria, then ranked and analyzed using Friedman's nonparametric test, at p=0.05. The results showed a significant difference between the preservation and the delay in urine fixation, p<0.0001. Any delay in fixation of urine specimen for cytology affects the preservation of cells, which may result in miss diagnosis. It is recommended that urine samples for cytology should be fixed immediately after collection.

  19. Direct analysis of δ2H and δ18O in natural and enriched human urine using laser-based, Off-Axis Integrated Cavity Output Spectroscopy

    PubMed Central

    Berman, Elena S.F.; Fortsona, Susan L.; Snaith, Steven P.; Gupta, Manish; Baer, Douglas S.; Chery, Isabelle; Blanc, Stephane; Melanson, Edward L.; Thomson, Peter J; Speakman, John R.

    2012-01-01

    The stable isotopes of hydrogen (δ2H) and oxygen (δ18O) in human urine are measured during studies of total energy expenditure by the doubly labeled water method, measurement of total body water, and measurement of insulin resistance by glucose disposal among other applications. An ultrasensitive laser absorption spectrometer based on off-axis integrated cavity output spectroscopy was demonstrated for simple and inexpensive measurement of stable isotopes in natural isotopic abundance and isotopically enriched human urine. Preparation of urine for analysis was simple and rapid (approx. 25 samples per hour), requiring no decolorizing or distillation steps. Analysis schemes were demonstrated to address sample-to-sample memory while still allowing analysis of 45 natural or 30 enriched urine samples per day. The instrument was linear over a wide range of water isotopes (δ2H = −454 to +1702 ‰ and δ18O= −58.3 to +265 ‰). Measurements of human urine were precise to better than 0.65 ‰ 1σ for δ2H and 0.09 ‰ 1σ for δ18O for natural urines, 1.1 ‰ 1σ for δ2H and 0.13 ‰ 1σ for δ18O for low enriched urines, and 1.0 ‰ 1σ for δ2H and 0.08 ‰ 1σ for δ18O for high enriched urines. Furthermore, the accuracy of the isotope measurements of human urines was verified to better than ±0.81 ‰ in δ2H and ±0.13 ‰ in δ18O (average deviation) against three independent IRMS laboratories. The ability to immediately and inexpensively measure the stable isotopes of water in human urine is expected to increase the number and variety of experiments which can be undertaken. PMID:23075099

  20. Accuracy of urinary human papillomavirus testing for presence of cervical HPV: systematic review and meta-analysis

    PubMed Central

    Pathak, Neha; Dodds, Julie; Khan, Khalid

    2014-01-01

    Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064

  1. [Is the renal excretion of orally applied diatrizoate (Gastrografin) a reliable marker of gastrointestinal perforation or dehiscence of a gastrointestinal anastomosis?].

    PubMed

    Born, M; Axmann, C; Kader, R; von Falkenhausen, M; Manka, C; Willinek, W A; Schild, H

    2004-11-01

    Renal excretion of orally or rectally applied Gastrografin is reported to be a reliable indicator of a perforation or a postoperative anastomotic dehiscence of the GI-tract. The study was conducted to determine whether increased attenuation of the urine measured by CT after oral or rectal application of Gastrografin can give reliable evidence of any leakage from the gastrointestinal tract. Urine samples of 33 patients, who underwent a Gastrografin-enhanced fluoroscopic examination of the esophagus or the GI-tract for different clinical reasons, were examined by CT. The samples had been taken immediately before and 60 to 90 minutes after application of 100 ml Gastrografin. The results were compared with those of 5 healthy volunteers, who took urine samples before, 30, 60, 90, and 120 minutes after drinking 100 ml of Gastrografin. Maximal attenuation of the volunteers' urine samples was achieved 60 to 90 minutes after Gastrografin application with a mean of 50 Hounsfield units (HU), SD = 17 HU. The urine of three patients with radiologically proven fistula or dehiscence of a GI-tract anastomosis had no relevant increase in attenuation. Three other cases without any clinical or radiological evidence of an anastomotic leak had a substantial increase in the attenuation of the urine probes (87, 110, and 290 HU, respectively). The CT-measured urine samples as evidence of renal excretion of orally or rectally applied Gastrografin are not reliable for the detection of leaks from the GI-tract.

  2. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  3. Genotyping for DQA1 and PM loci in urine using PCR-based amplification: effects of sample volume, storage temperature, preservatives, and aging on DNA extraction and typing.

    PubMed

    Vu, N T; Chaturvedi, A K; Canfield, D V

    1999-05-31

    Urine is often the sample of choice for drug screening in aviation/general forensic toxicology and in workplace drug testing. In some instances, the origin of the submitted samples may be challenged because of the medicolegal and socioeconomic consequences of a positive drug test. Methods for individualization of biological samples have reached a new boundary with the application of the polymerase chain reaction (PCR) in DNA profiling, but a successful characterization of the urine specimens depends on the quantity and quality of DNA present in the samples. Therefore, the present study investigated the influence of storage conditions, sample volume, concentration modes, extraction procedures, and chemical preservations on the quantity of DNA recovered, as well as the success rate of PCR-based genotyping for DQA1 and PM loci in urine. Urine specimens from male and female volunteers were divided and stored at various temperatures for up to 30 days. The results suggested that sample purification by dialfiltration, using 3000-100,000 molecular weight cut-off filters, did not enhance DNA recovery and typing rate as compared with simple centrifugation procedures. Extraction of urinary DNA by the organic method and by the resin method gave comparable typing results. Larger sample volume yielded a higher amount of DNA, but the typing rates were not affected for sample volumes between 1 and 5 ml. The quantifiable amounts of DNA present were found to be greater in female (14-200 ng/ml) than in male (4-60 ng/ml) samples and decreased with the elapsed time under both room temperature (RT) and frozen storage. Typing of the male samples also demonstrated that RT storage samples produced significantly higher success rates than that of frozen samples, while there was only marginal difference in the DNA typing rates among the conditions tested using female samples. Successful assignment of DQA1 + PM genotype was achieved for all samples of fresh urine, independent of gender, starting sample volume, or concentration method. Preservation by 0.25% sodium azide was acceptable for sample storage at 4 degrees C during a period of 30 days. For longer storage duration, freezing at -70 degrees C may be more appropriate. Thus, the applicability of the DQA1 + PM typing was clearly demonstrated for individualization of urine samples.

  4. Phthalate metabolites in Norwegian mothers and children: Levels, diurnal variation and use of personal care products.

    PubMed

    Sakhi, Amrit Kaur; Sabaredzovic, Azemira; Cequier, Enrique; Thomsen, Cathrine

    2017-12-01

    Exposure to phthalates has been associated with reproductive and developmental toxicity. Data on levels of these compounds in the Norwegian population is limited. In this study, urine samples were collected from 48 mothers and their children in two counties in Norway. Eleven different phthalate metabolites originating from six commonly used phthalates in consumer products were determined. Concentrations of phthalate metabolites were significantly higher in children compared to mothers except for mono-ethyl phthalate (MEP). The mothers provided several urine samples during 24hours (h) and diurnal variation showed that the concentrations in the morning urine samples (24-8h) were significantly higher than at other time-periods for most of the phthalate metabolites. Intraclass correlation coefficients (ICCs) for 24-hour time-period were in the range of 0.49-0.81. These moderate to high ICCs indicate that one spot urine sample can be used to estimate the exposure to phthalates. Since a significant effect of time of day was observed, it is still advisable to standardize the collection time point to reduce the variation. For the mothers, the use of personal care products (PCPs) were less associated with morning urine samples than early day (8-12h) and evening (16-24h) urine samples. The use of perfume and hair products were positively associated with the urinary concentrations of low molecular weight phthalates. Use of shower soap and shampoo were positively associated with urinary concentration of di(2-ethylhexyl) phthalate (DEHP) metabolites. For children, face cream use was positively associated with phthalate metabolites in the morning samples, and hand soap use was negatively associated with concentration of urinary DEHP metabolites in afternoon/evening samples. Since different PCPs were associated with the urinary phthalate metabolites in different time-periods during a day, more than one spot urine sample might be required to study associations between urinary phthalate metabolites and the use of PCPs. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Coca tea consumption causes positive urine cocaine assay.

    PubMed

    Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy

    2006-12-01

    Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.

  6. Potential of non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Shaohua; Wang, Lan; Chen, Weisheng; Feng, Shangyuan; Lin, Juqiang; Huang, Zufang; Chen, Guannan; Li, Buhong; Chen, Rong

    2014-11-01

    Non-invasive esophagus cancer detection based on urine surface-enhanced Raman spectroscopy (SERS) analysis was presented. Urine SERS spectra were measured on esophagus cancer patients (n = 56) and healthy volunteers (n = 36) for control analysis. Tentative assignments of the urine SERS spectra indicated some interesting esophagus cancer-specific biomolecular changes, including a decrease in the relative content of urea and an increase in the percentage of uric acid in the urine of esophagus cancer patients compared to that of healthy subjects. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was employed to analyze and differentiate the SERS spectra between normal and esophagus cancer urine. The diagnostic algorithms utilizing a multivariate analysis method achieved a diagnostic sensitivity of 89.3% and specificity of 83.3% for separating esophagus cancer samples from normal urine samples. These results from the explorative work suggested that silver nano particle-based urine SERS analysis coupled with PCA-LDA multivariate analysis has potential for non-invasive detection of esophagus cancer.

  7. Ultrasonic-based membrane aided sample preparation of urine proteomes.

    PubMed

    Jesus, Jemmyson Romário; Santos, Hugo M; López-Fernández, H; Lodeiro, Carlos; Arruda, Marco Aurélio Zezzi; Capelo, J L

    2018-02-01

    A new ultrafast ultrasonic-based method for shotgun proteomics as well as label-free protein quantification in urine samples is developed. The method first separates the urine proteins using nitrocellulose-based membranes and then proteins are in-membrane digested using trypsin. The enzymatic digestion process is accelerated from overnight to four minutes using a sonoreactor ultrasonic device. Overall, the sample treatment pipeline comprising protein separation, digestion and identification is done in just 3h. The process is assessed using urine of healthy volunteers. The method shows that male can be differentiated from female using the protein content of urine in a fast, easy and straightforward way. 232 and 226 proteins are identified in urine of male and female, respectively. From this, 162 are common to both genders, whilst 70 are unique to male and 64 to female. From the 162 common proteins, 13 are present at levels statistically different (p < 0.05). The method matches the analytical minimalism concept as outlined by Halls, as each stage of this analysis is evaluated to minimize the time, cost, sample requirement, reagent consumption, energy requirements and production of waste products. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Pre-analytical Factors Influence Accuracy of Urine Spot Iodine Assessment in Epidemiological Surveys.

    PubMed

    Doggui, Radhouene; El Ati-Hellal, Myriam; Traissac, Pierre; El Ati, Jalila

    2018-03-26

    Urinary iodine concentration (UIC) is commonly used to assess iodine status of subjects in epidemiological surveys. As pre-analytical factors are an important source of measurement error and studies about this phase are scarce, our objective was to assess the influence of urine sampling conditions on UIC, i.e., whether the child ate breakfast or not, urine void rank of the day, and time span between last meal and urine collection. A nationwide, two-stage, stratified, cross-sectional study including 1560 children (6-12 years) was performed in 2012. UIC was determined by the Sandell-Kolthoff method. Pre-analytical factors were assessed from children's mothers by using a questionnaire. Association between iodine status and pre-analytical factors were adjusted for one another and socio-economic characteristics by multivariate linear and multinomial regression models (RPR: relative prevalence ratios). Skipping breakfast prior to morning urine sampling decreased UIC by 40 to 50 μg/L and the proportion of UIC < 100 μg/L was higher among children having those skipped breakfast (RPR = 3.2[1.0-10.4]). In unadjusted analyses, UIC was less among children sampled more than 5 h from their last meal. UIC decreased with rank of urine void (e.g., first vs. second, P < 0.001); also, the proportion of UIC < 100 μg/L was greater among 4th rank samples (vs. second RPR = 2.1[1.1-4.0]). Subjects' breakfast status and urine void rank should be accounted for when assessing iodine status. Providing recommendations to standardize pre-analytical factors is a key step toward improving accuracy and comparability of survey results for assessing iodine status from spot urine samples. These recommendations have to be evaluated by future research.

  9. Evaluation of take-home organophosphorus pesticide exposure among agricultural workers and their children.

    PubMed Central

    Curl, Cynthia L; Fenske, Richard A; Kissel, John C; Shirai, Jeffry H; Moate, Thomas F; Griffith, William; Coronado, Gloria; Thompson, Beti

    2002-01-01

    We analyzed organophosphorus pesticide exposure in 218 farm worker households in agricultural communities in Washington State to investigate the take-home pathway of pesticide exposure and to establish baseline exposure levels for a community intervention project. House dust samples (n = 156) were collected from within the homes, and vehicle dust samples (n = 190) were collected from the vehicles used by the farm workers to commute to and from work. Urine samples were obtained from a farm worker (n = 213) and a young child (n = 211) in each household. Dust samples were analyzed for six pesticides, and urine samples were analyzed for five dialkylphosphate (DAP) metabolites. Azinphosmethyl was detected in higher concentrations (p < 0.0001) than the other pesticides: geometric mean concentrations of azinphosmethyl were 0.53 micro g/g in house dust and 0.75 micro g/g in vehicle dust. Dimethyl DAP metabolite concentrations were higher than diethyl DAP metabolite concentrations in both child and adult urine (p < 0.0001). Geometric mean dimethyl DAP concentrations were 0.13 micro mol/L in adult urine and 0.09 micro mol/L in child urine. Creatinine-adjusted geometric mean dimethyl DAP concentrations were 0.09 micro mol/g in adult urine and 0.14 micro mol/g in child urine. Azinphosmethyl concentrations in house dust and vehicle dust from the same household were significantly associated (r2 = 0.41, p < 0.0001). Dimethyl DAP levels in child and adult urine from the same household were also significantly associated (r2 = 0.18, p < 0.0001), and this association remained when the values were creatinine adjusted. The results of this work support the hypothesis that the take-home exposure pathway contributes to residential pesticide contamination in agricultural homes where young children are present. PMID:12460819

  10. Urine Monitoring System

    NASA Technical Reports Server (NTRS)

    Feedback, Daniel L.; Cibuzar, Branelle R.

    2009-01-01

    The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.

  11. Using urinary 1-hydroxypyrene concentrations to evaluate polycyclic aromatic hydrocarbon exposure in women using biomass combustion as main energy source.

    PubMed

    Ruíz-Vera, Tania; Pruneda-Alvarez, Lucia G; Pérez-Vázquez, Francisco J; Ochoa-Martínez, Angeles C; Orta-García, Sandra T; Ilizaliturri-Hernández, Cesar A; Pérez-Maldonado, Iván N

    2015-01-01

    The use of solid fuels for cooking and heating is likely to be the largest source of indoor air pollution on a global scale. The aim of this study was to investigate the urinary excretion of 1-hydroxypyrene (1-OHP) in women living in a rural community, where biomass combustion is used as main energy source during a working day. The study was performed on urine samples collected in 2012, of 30 healthy women who were residents of a rural community in San Luis Potosi, Mexico. Urine was collected from each woman at three time points (morning, post-lunch and evening) during a working day. The analysis of urinary 1-OHP was performed using high-performance liquid chromatography (HPLC). Also, a health-risk assessment was conducted. The highest levels of 1-OHP in this study were found in the samples taken in the evening (geometric mean ± SD; 0.36 ± 0.13 µg/g creatinine). However, no significant differences among 1-OHP concentrations in the evening and post-lunch samples (0.27 ± 0.10 µg/g creatinine; 0.58 ± 0.67 µg/L) were observed. But, the 1-OHP levels (0.17 ± 0.13 µg/g creatinine; 0.19 ± 0.21 µg/L) found in samples collected in the morning were significantly lower than the 1-OHP levels found in samples collected during post-lunch and evening time. The data shown in this study demonstrated an increment in the exposure levels to PAHs in women across the shift. However, no health risk was found in this study.

  12. A study of ethylene glycol exposure and kidney function of aircraft de-icing workers.

    PubMed

    Gérin, M; Patrice, S; Bégin, D; Goldberg, M S; Vyskocil, A; Adib, G; Drolet, D; Viau, C

    1997-01-01

    Ethylene glycol levels were measured in 154 breathing zone air samples and in 117 urine samples of 33 aviation workers exposed to de-icing fluid (basket operators, de-icing truck drivers, leads and coordinators) studied during 42 worker-days over a winter period of 2 months at a Montreal airport. Ethylene glycol as vapour did not exceed 22 mg/m3 (mean duration of samples 50 min). Mist was quantified at higher levels in 3 samples concerning 1 coordinator and 2 basket operators (76-190 mg/m3, 45-118 min). In 16 cases workers' post-shift or next-morning urine contained quantities of ethylene glycol exceeding 5 mmol/mol creatinine (up to 129 mmol/mol creatinine), with most of these instances occurring in basket operators and coordinators, some of whom did not wear paper masks and/or were accidentally sprayed with de-icing fluid. Diethylene glycol was also found in a few air and urinary samples at levels around one tenth those of ethylene glycol. Urinary concentrations of albumin, beta-N-acetyl-glucosaminidase, beta-2-microglobulin and retinol-binding protein were measured and compared over various periods, according to subgroups based on exposure level and according to the frequency of extreme values. These analyses did not demonstrate acute or chronic kidney damage that could be attributed to working in the presence of ethylene glycol. In conclusion, this study does not suggest important health effects of exposure to de-icing fluid in this group of workers. Potential for overexposure exists, however, in certain work situations, and recommendations on preventive measures are given. In addition, these results suggest that other routes of absorption than inhalation, such as the percutaneous route, may be important and that urinary ethylene glycol may be a useful indicator of exposure to ethylene glycol.

  13. Excreta Sampling as an Alternative to In Vivo Measurements at the Hanford Site.

    PubMed

    Carbaugh, Eugene H; Antonio, Cheryl L; Lynch, Timothy P

    2015-08-01

    The capabilities of indirect radiobioassay by urine and fecal sample analysis were compared with the direct radiobioassay methods of whole body counting and lung counting for the most common radionuclides and inhalation exposure scenarios encountered by Hanford workers. Radionuclides addressed by in vivo measurement included 137Cs, 60Co, 154Eu, and 241Am as an indicator for plutonium mixtures. The same radionuclides were addressed using gamma energy analysis of urine samples, augmented by radiochemistry and alpha spectrometry methods for plutonium in urine and fecal samples. It was concluded that in vivo whole body counting and lung counting capability should be maintained at the Hanford Site for the foreseeable future, however, urine and fecal sample analysis could provide adequate, though degraded, monitoring capability for workers as a short-term alternative, should in vivo capability be lost due to planned or unplanned circumstances.

  14. The use of laser-induced fluorescence or ultraviolet detectors for sensitive and selective analysis of tobramycin or erythropoietin in complex samples

    NASA Astrophysics Data System (ADS)

    Ahmed, Hytham M.; Ebeid, Wael B.

    2015-05-01

    Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200 ng/ml respectively and recovery was >98% (n = 5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000 IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period.

  15. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  16. Pilot-Plant Demonstration of Wet Oxidation for Treatment of Shipboard Wastewaters.

    DTIC Science & Technology

    1975-11-01

    minus mg of COD removed in prior sampling )] Table I indicates that, when the reactor was last sampled after six injections Pf concentrated feces and urine ...oxidation of feces and urine is of an inorganic nature. The pH of most of the samples taken in thes tests was measured using indi- cator papers. All...BATCH EXPERIMENTS ON FECES AND URINE IN rRESENCE OF BARBER-COLMAN CO. CATALYST 10,480 ............. . E.1 lest Procedure ......... . E-3 E.2 Test

  17. Study of tamoxifen urinary metabolites in rat by ultra-high-performance liquid chromatography time-of-flight mass spectrometry.

    PubMed

    Domínguez-Romero, Juan C; García-Reyes, Juan F; Beneito-Cambra, Miriam; Martínez-Romero, Rubén; Martinez-Lara, Esther; Del Moral-Leal, María L; Molina-Díaz, Antonio

    2015-08-01

    Tamoxifen (TMX) is a nonsteroidal estrogen antagonist drug used for the treatment of breast cancer. It is also included in the list of banned substances of the World Anti Doping Agency (WADA) prohibited in and out of competition. In this work, the excretion of urinary metabolites of TMX after a single therapeutic dose administration in rats has been studied using ultra-high-performance liquid chromatography electrospray time-of-flight mass spectrometry (UHPLC-TOFMS). A systematic strategy based on the search of typical biotransformations that a xenobiotic can undergo in living organisms, based on their corresponding molecular formula modification and accurate mass shifts, was applied for the identification of TMX metabolites. Prior to UHPLC-TOFMS analyses, a solid-phase extraction step with polymeric cartridges was applied to urine samples. Up to 38 TMX metabolites were detected. Additional collision induced dissociation (CID) MS/MS fragmentation was performed using UHPLC-QTOFMS. Compared with recent previous studies in human urine and plasma, new metabolites have been reported for the first time in urine. Metabolites identified in rat urine include the oxygen addition, owing to different possibilities for the hydroxylation of the rings in different positions (m/z 388.2271), the incorporation of two oxygen atoms (m/z 404.2220) (including dihydroxylated derivatives or alternatives such as epoxidation plus hydroxylation or N-oxidation and hydroxylation), epoxide formation or hydroxylation and dehydrogenation [m/z 386.2114 (+O -H2 )], hydroxylation of the ring accompanied by N-desmethylation (m/z 374.2115), combined hydroxylation and methoxylation (m/z 418.2377), desaturated TMX derivate (m/z 370.2165) and its N-desmethylated derivate (m/z 356.2009), the two latter modifications not previously being reported in urine. These findings confirm the usefulness of the proposed approach based on UHPLC-TOFMS. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Hydrogen and Oxygen Stable Isotope Fractionation in Body Fluid Compartments of Dairy Cattle According to Season, Farm, Breed, and Reproductive Stage

    PubMed Central

    Abeni, Fabio; Petrera, Francesca; Capelletti, Maurizio; Dal Prà, Aldo; Bontempo, Luana; Tonon, Agostino; Camin, Federica

    2015-01-01

    Environmental temperature affects water turnover and isotope fractionation by causing water evaporation from the body in mammals. This may lead to rearrangement of the water stable isotope equilibrium in body fluids. We propose an approach to detect possible variations in the isotope ratio in different body fluids on the basis of different homoeothermic adaptations in varying reproductive stages. Three different reproductive stages (pregnant heifer, primiparous lactating cow, and pluriparous lactating cow) of two dairy cattle breeds (Italian Friesian and Modenese) were studied in winter and summer. Blood plasma, urine, faecal water, and milk were sampled and the isotope ratios of H (2H/1H) and O (18O/16O) were determined. Deuterium excess and isotope-fractionation factors were calculated for each passage from plasma to faeces, urine and milk. The effects of the season, reproductive stages and breed on δ 2H and δ 18O were significant in all the fluids, with few exceptions. Deuterium excess was affected by season in all the analysed fluids. The correlations between water isotope measurements in bovine body fluids ranged between 0.6936 (urine-milk) and 0.7848 (urine-plasma) for δ 2H, and between 0.8705 (urine-milk) and 0.9602 (plasma-milk) for δ 18O. The increase in both isotopic δ values in all body fluids during summer is representative of a condition in which fractionation took place as a consequence of a different ratio between ingested and excreted water, which leads to an increased presence of the heavy isotopes. The different body water turnover between adult lactating cattle and non-lactating heifers was confirmed by the higher isotopic δ for the latter, with a shift in the isotopic equilibrium towards values more distant from those of drinking water. PMID:25996911

  19. Oxidatively damaged guanosine in white blood cells and in urine of welders: associations with exposure to welding fumes and body iron stores.

    PubMed

    Pesch, Beate; Lotz, Anne; Koch, Holger M; Marczynski, Boleslaw; Casjens, Swaantje; Käfferlein, Heiko U; Welge, Peter; Lehnert, Martin; Heinze, Evelyn; Van Gelder, Rainer; Hahn, Jens-Uwe; Behrens, Thomas; Raulf, Monika; Hartwig, Andrea; Weiss, Tobias; Brüning, Thomas

    2015-08-01

    The International Agency for Research on Cancer considers the carcinogenicity of welding fume of priority for re-evaluation. Genotoxic effects in experimental animals are still inconclusive. Here, we investigated the association of personal exposure to metals in respirable welding fumes during a working shift with oxidatively damaged guanosine in DNA of white blood cells (WBC) and in postshift urine samples from 238 welders. Medians of 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) were 2.35/10(6) dGuo in DNA of WBC and 4.33 µg/g creatinine in urine. The median of 8-oxo-7,8-dihydroguanosine (8-oxoGuo) was 7.03 µg/g creatinine in urine. The extent of both urinary parameters was higher in welders applying techniques with high particle emission rates to stainless steel than in tungsten inert gas welders (8-oxodGuo: 9.96 vs. 4.49 µg/L, 8-oxoGuo: 15.7 vs. 7.7 µg/L), but this apparent difference diminished after creatinine adjustment. We applied random intercept models to estimate the influence of airborne and systemic exposure to metals on oxidatively damaged guanosine in WBC and urine together with covariates. We observed a highly significant nonlinear association of urinary 8-oxoGuo with serum ferritin (P < 0.0001) and higher 8-oxoGuo concentrations for respirable iron >1,000 µg/m(3) compared to ≤57 µg/m(3). Similar effects were found for manganese. Airborne chromium but not nickel was associated with all oxidatively modified guanosine measures, whereas urinary chromium as well as nickel showed associations with urinary modified guanosines. In summary, oxidatively damaged urinary guanosine was associated with airborne and systemic exposure to metals in welders and showed a strong relation to body iron stores.

  20. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    PubMed

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Arsenic, cadmium, lead, and chromium in well water, rice, and human urine in Sri Lanka in relation to chronic kidney disease of unknown etiology.

    PubMed

    S Herath, H M Ayala; Kawakami, Tomonori; Nagasawa, Shiori; Serikawa, Yuka; Motoyama, Ayuri; Chaminda, G G Tushara; Weragoda, S K; Yatigammana, S K; Amarasooriya, A A G D

    2018-04-01

    Chronic kidney disease of unknown etiology (CKDu) is spreading gradually in Sri Lanka. In the current research, 1,435 well water samples from all 25 districts of Sri Lanka, 91 rice samples, and 84 human urine samples from both CKDu-endemic and non-endemic areas in Sri Lanka were analyzed for arsenic, cadmium, lead, and chromium to detect whether toxic elements could be a cause of CKDu. The liver-type fatty acid binding protein (L-FABP) concentration and arsenic, cadmium, lead, and chromium concentrations of the urine samples were analyzed to determine the relation of L-FABP with arsenic, cadmium, lead, and chromium. High concentrations of arsenic, cadmium, lead, and chromium were not detected in the well water samples from CKDu-endemic areas. Arsenic, cadmium, and lead contents in the rice samples from both CKDu-endemic and non-endemic areas were well below the Codex standard. There were no relationships between the L-FABP concentration and concentrations of arsenic, cadmium, lead, and chromium in urine. In addition, arsenic, cadmium, lead, and chromium concentrations in human urine samples from CKDu-endemic areas were not significantly different from those from non-endemic areas. These findings indicated that arsenic, cadmium, lead, and chromium could not cause CKDu.

  2. Comparison of Sofia Legionella FIA and BinaxNOW® Legionella urinary antigen card in two national reference centers.

    PubMed

    Beraud, L; Gervasoni, K; Freydiere, A M; Descours, G; Ranc, A G; Vandenesch, F; Lina, G; Gaia, V; Jarraud, S

    2015-09-01

    The Sofia Legionella Fluorescence Immunoassay (FIA; Quidel) is a recently introduced rapid immunochromatographic diagnostic test for Legionnaires' disease using immunofluorescence technology designed to enhance its sensitivity. The aim of this study was to evaluate its performance for the detection of urinary antigens for Legionella pneumophila serogroup 1 in two National Reference Centers for Legionella. The sensitivity and specificity of the Sofia Legionella FIA test were determined in concentrated and nonconcentrated urine samples, before and after boiling, in comparison with the BinaxNOW® Legionella Urinary Antigen Card (UAC; Alere). Compared with BinaxNOW® Legionella UAC, the sensitivity of the Sofia Legionella test was slightly higher in nonconcentrated urine samples and was identical in concentrated urine samples. The specificity of the Sofia Legionella FIA test was highly reduced by the concentration of urine samples. In nonconcentrated samples, a lack of specificity was observed in 2.3 % of samples, all of them resolved by heat treatment. The Sofia Legionella FIA is a sensitive test for detecting Legionella urinary antigens with no previous urine concentration. However, all positive samples have to be re-tested after boiling to reach a high specificity. The reading is automatized on the Sofia analyzer, which can be connected to laboratory information systems, facilitating accurate and rapid reporting of results.

  3. High-throughput analysis of amphetamines in blood and urine with online solid-phase extraction-liquid chromatography-tandem mass spectrometry.

    PubMed

    Fernández, María del Mar Ramírez; Wille, Sarah M R; Samyn, Nele; Wood, Michelle; López-Rivadulla, Manuel; De Boeck, Gert

    2009-01-01

    An automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of amphetamines in blood and urine was developed and validated. Chromatographic separation was achieved on a Nucleodur Sphinx RP column with an LC gradient (a mixture of 10 mM ammonium formate buffer and acetonitrile), ensuring the elution of amphetamine, methamphetamine, MDMA, MDA, MDEA, PMA, and ephedrine within 11 min. The method was fully validated, according to international guidelines, using only 100 and 50 microL of blood and urine, respectively. The method showed an excellent intra- and interassay precision (relative standard deviation < 11.2% and bias < 13%) for two external quality control samples (QC) for both matrices and three and two 'in house' QCs for blood and urine, respectively. Responses were linear over the investigated range (r(2) > 0.99, 2.5-400 microg/L for blood and 25-1000 microg/L for urine). Limits of quantification were determined to be 2.5 and 25 microg/L for blood and urine, respectively. Limits of detection ranged from 0.05 to 0.5 microg/L for blood and 0.25 to 2.5 microg/L for urine, depending on the compound. Furthermore, the analytes and the processed samples were demonstrated to be stable (in the autosampler for at least 72 h and after three freeze/thaw cycles), and no disturbing matrix effects were observed for all compounds. Moreover, no carryover was observed after the analysis of high concentration samples (15,000 microg/L). The method was subsequently applied to authentic blood and urine samples obtained from forensic cases, which covered a broad range of concentrations. The validation results and actual sample analyses demonstrated that this method is rugged, precise, accurate, and well-suited for routine analysis as more than 72 samples are analyzed non-stop in 24 h with minimum sample handling. The combination of the high-throughput online SPE and the well-known sensitivity and selectivity assured by MS-MS resulted in the elimination of the bottleneck associated with the sample preparation requirements and provided increased sensitivity, accuracy, and precision.

  4. Fluoride in drinking water and human urine in Southern Haryana, India.

    PubMed

    Singh, Bhupinder; Gaur, Shalini; Garg, V K

    2007-06-01

    The objective of this study was to determine the fluoride content in drinking water and urine samples of adolescent males aged 11-16 years living in Southern Haryana, India. A total of 30 drinking water sources in the studied habitations were assessed for fluoride contamination. Fluoride was estimated in the urine of 400 male children randomly selected from these habitations. The fluoride concentration in drinking water and urine samples was determined using USEPA fluoride ion selective electrode method. The mean fluoride concentration in drinking water samples of Pataudi, Haily Mandi and Harsaru villages was 1.68+/-0.35, 3.22+/-1.18 and 1.78+/-0.12 mg/l, respectively. The mean urinary fluoride concentration was 2.26+/-0.024 mg/l at Pataudi, 2.48+/-0.77 mg/l at Haily Mandi and 2.43+/-0.84 mg/l at Harsaru village. The higher fluoride levels in the urine of children may be associated to higher fluoride levels in drinking water. The accuracy of measurements was assessed with known addition method in water and urine. Mean fluoride recovery was 98.0 and 99.1% in water and urine. The levels obtained were reproducible with in +/-3% error limit.

  5. Presence of infective Epstein-Barr virus in the urine of patients with infectious mononucleosis.

    PubMed

    Landau, Z; Gross, R; Sanilevich, A; Friedmann, A; Mitrani-Rosenbaum, S

    1994-11-01

    The presence of Epstein-Barr virus (EBV) in the blood and urine of 20 patients with infectious mononucleosis (IM) was investigated together with the clinical course of the disease, and in 9 patients up to 2-7 months after recovery. EBV DNA, analyzed by the polymerase chain reaction (PCR), was detected in the blood of all 20 patients from the first sample obtained and detected between 3 to 42 days from the beginning of symptoms and up to 2-3 months after recovery. In the urine, EBV DNA was detected in 15 out of 16 (93%) patients in the first sample obtained and detected between 3 to 50 days during the clinical course of the disease. In four patients EBV DNA was detected in the urine up to 3 months after full recovery. Seventeen out of 26 (65%) urine samples including 3 which were obtained 2-7 months after recovery infected B cells as assessed by PCR. Nine out of 12 (75%) urine samples tested induced Epstein-Barr nuclear antigen (EBNA) in the infected B-cell line. In addition to the persistence of EBV in the blood of IM patients, these studies show for the first time the presence of infective EBV in the urine during the clinical course of the disease and up to 7 months after full clinical recovery.

  6. [Assessment of dietary intake and urinary excretion of sodium and potassium in adults].

    PubMed

    Cornejo, Karen; Pizarro, Fernando; Atalah, Eduardo; Galgani, José E

    2014-06-01

    Hypertension is associated with elevated sodium and low potassium intakes. The determination of sodium and potassium intake by dietary records is inaccurate, being its measurement from 24-h urine collection the reference method. To determine urinary sodium and potassium excretion in adults. To compare dietary sodium and potassium intake and their excretion from an isolated urine sample against the reference method. Seventy healthy adults aged 35 ± 8 years with a body mass index 25 ± 2 kg/m² (36 women) were studied. Urine was collected over 24 h, including an isolated urine sample taken in fasting conditions. Additionally, three 24-h dietary records were performed. Reported sodium and potassium intake was 2,720 ± 567 and 1,068 ± 433 mg/day, respectively. In turn, urinary excretion of sodium and potassium was 4,770 ± 1,532 and 1,852 ± 559 mg/day, respectively. These latter values were significantly higher than those obtained by dietary records. Furthermore, the urinary sodium and potassium excretion estimated from an isolated urine sample was 4,839 ± 1,355 and 1,845 ± 494 mg/day, respectively. These values were similar to those obtained with a 24 h urine collection. Dietary records underestimated electrolyte intake when compared with the reference method. Using an isolated urine sample to estimate electrolyte intake may be a reliable alternative.

  7. Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

    NASA Technical Reports Server (NTRS)

    Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)

    1973-01-01

    An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

  8. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    PubMed

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  9. Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens

    PubMed Central

    Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe

    2015-01-01

    Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240

  10. Nappy pad urine samples for investigation and treatment of UTI in young children: the 'DUTY' prospective diagnostic cohort study.

    PubMed

    Butler, Christopher C; Sterne, Jonathan Ac; Lawton, Michael; O'Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-07-01

    The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Acutely unwell children <5 years presenting to 233 UK primary care sites. Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs' 'working diagnosis' had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were 'frankly contaminated' (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. © British Journal of General Practice 2016.

  11. Doping control study of AICAR in post-race urine and plasma samples from horses.

    PubMed

    Wong, Jenny K Y; Kwok, Wai Him; Chan, George H M; Choi, Timmy L S; Ho, Emmie N M; Jaubert, Murielle; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Cawley, Adam; Ming Williams, H; Keledjian, John; Brooks, Lydia; Chambers, Adam; Lin, Yuanyuan; Wan, Terence S M

    2017-09-01

    Acadesine, 5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside, commonly known as AICAR, is a naturally occurring adenosine monophosphate-activated protein kinase (AMPK) activator in many mammals, including humans and horses. AICAR has attracted considerable attention recently in the field of doping control because of a study showing the enhancement of endurance performance in unexercised or untrained mice, resulting in the term 'exercise pill'. Its use has been classified as gene doping by the World Anti-Doping Agency (WADA), and since it is endogenous, it may only be possible to control deliberate administration of AICAR to racehorses after establishment of an appropriate threshold. Herein we report our studies of AICAR in post-race equine urine and plasma samples including statistical studies of AICAR concentrations determined from 1,470 urine samples collected from thoroughbreds and standardbreds and analyzed in Australia, France, and Hong Kong. Quantification methods in equine urine and plasma using liquid chromatography-mass spectrometry were developed by the laboratories in each country. An exchange of spiked urine and plasma samples between the three countries was conducted, confirming no significant differences in the methods. However, the concentration of AICAR in plasma was found to increase upon haemolysis of whole blood samples, impeding the establishment of a suitable threshold in equine plasma. A possible urine screening cut-off at 600 ng/mL for the control of AICAR in racehorses could be considered for adoption. Application of the proposed screening cut-off to urine samples collected after intravenous administration of a small dose (2 g) of AICAR to a mare yielded a short detection time of approximately 4.5 h. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Nappy pad urine samples for investigation and treatment of UTI in young children: the ‘DUTY’ prospective diagnostic cohort study

    PubMed Central

    Butler, Christopher C; Sterne, Jonathan AC; Lawton, Michael; O’Brien, Kathryn; Wootton, Mandy; Hood, Kerenza; Hollingworth, William; Little, Paul; Delaney, Brendan C; van der Voort, Judith; Dudley, Jan; Birnie, Kate; Pickles, Timothy; Waldron, Cherry-Ann; Downing, Harriet; Thomas-Jones, Emma; Lisles, Catherine; Rumsby, Kate; Durbaba, Stevo; Whiting, Penny; Harman, Kim; Howe, Robin; MacGowan, Alasdair; Fletcher, Margaret; Hay, Alastair D

    2016-01-01

    Background The added diagnostic utility of nappy pad urine samples and the proportion that are contaminated is unknown. Aim To develop a clinical prediction rule for the diagnosis of urinary tract infection (UTI) based on sampling using the nappy pad method. Design and setting Acutely unwell children <5 years presenting to 233 UK primary care sites. Method Logistic regression to identify independent associations of symptoms, signs, and urine dipstick test results with UTI; diagnostic utility quantified as area under the receiver operator curves (AUROC). Nappy pad rule characteristics, AUROC, and contamination, compared with findings from clean-catch samples. Results Nappy pad samples were obtained from 3205 children (82% aged <2 years; 48% female), culture results were available for 2277 (71.0%) and 30 (1.3%) had a UTI on culture. Female sex, smelly urine, darker urine, and the absence of nappy rash were independently associated with a UTI, with an internally-validated, coefficient model AUROC of 0.81 (0.87 for clean-catch), which increased to 0.87 (0.90 for clean-catch) with the addition of dipstick results. GPs’ ‘working diagnosis’ had an AUROC 0.63 (95% confidence intervals [CI] = 0.53 to 0.72). A total of 12.2% of nappy pad and 1.8% of clean-catch samples were ‘frankly contaminated’ (risk ratio 6.66; 95% CI = 4.95 to 8.96; P<0.001). Conclusion Nappy pad urine culture results, with features that can be reported by parents and dipstick tests, can be clinically useful, but are less accurate and more often contaminated compared with clean-catch urine culture. PMID:27364678

  13. Estimation of D-Arabinose by Gas Chromatography/Mass Spectrometry as Surrogate for Mycobacterial Lipoarabinomannan in Human Urine

    PubMed Central

    De, Prithwiraj; Amin, Anita G.; Valli, Eloise; Perkins, Mark D.; McNeil, Michael; Chatterjee, Delphi

    2015-01-01

    Globally, tuberculosis is slowly declining each year and it is estimated that 37 million lives were saved between 2000 and 2013 through effective diagnosis and treatment. Currently, diagnosis relies on demonstration of the bacteria, Mycobacterium tuberculosis (Mtb), in clinical specimens by serial sputum microscopy, culture and molecular testing. Commercial immunoassay lateral flow kits developed to detect Mtb lipoglycan lipoarabinomannan (LAM) in urine as a marker of active TB exhibit poor sensitivity, especially in immunocompetent individuals, perhaps due to low abundance of the analyte. Our present study was designed to develop methods to validate the presence of LAM in a quantitative fashion in human urine samples obtained from culture-confirmed TB patients. Herein we describe, a consolidated approach for isolating LAM from the urine and quantifying D-arabinose as a proxy for LAM, using Gas Chromatography/Mass Spectrometry. 298 urine samples obtained from a repository were rigorously analyzed and shown to contain varying amounts of LAM-equivalent ranging between ~10–40 ng/mL. To further substantiate that D-arabinose detected in the samples originated from LAM, tuberculostearic acid, the unique 10-methyloctadecanoic acid present at the phosphatidylinositol end of LAM was also analyzed in a set of samples and found to be present confirming that the D-arabinose was indeed derived from LAM. Among the 144 samples from culture-negative TB suspects, 30 showed presence of D-arabinose suggesting another source of the analyte, such as disseminated TB or from non-tuberculosis mycobacterium. Our work validates that LAM is present in the urine samples of culture-positive patients in small but readily detectable amounts. The study further substantiates LAM in urine as a powerful biomarker for active tuberculosis. PMID:26633829

  14. A population study of urine glycerol concentrations in elite athletes competing in North America.

    PubMed

    Kelly, Brian N; Madsen, Myke; Sharpe, Ken; Nair, Vinod; Eichner, Daniel

    2013-01-01

    Glycerol is an endogenous substance that is on the World Anti-Doping Agency's list of prohibited threshold substances due to its potential use as a plasma volume expansion agent. The WADA has set the threshold for urine glycerol, including measurement uncertainty, at 1.3 mg/mL. Glycerol in circulation largely comes from metabolism of triglycerides in order to meet energy requirements and when the renal threshold is eclipsed, glycerol is excreted into urine. In part due to ethnic differences in postprandial triglyceride concentrations, we investigated urine glycerol concentrations in a population of elite athletes competing in North America and compared the results to those of athletes competing in Europe. 959 urine samples from elite athletes competing in North America collected for anti-doping purposes were analyzed for urine glycerol concentrations by a gas chromatography mass-spectrometry method. Samples were divided into groups according to: Timing (in- or out-of-competition), Class (strength, game, or endurance sports) and Gender. 333 (34.7%) samples had undetectable amounts of glycerol (<1 μg/mL). 861 (89.8%) of the samples had glycerol concentrations ≤20 μg/mL. The highest glycerol concentration observed was 652 μg/mL. Analysis of the data finds the effects of each category to be statistically significant. The largest estimate of the 99.9(th) percentile, from the in-competition, female, strength athlete samples, was 1813 μg/mL with a 95% confidence range from 774 to 4251 μg/mL. This suggests a conservative threshold of 4.3 mg/mL, which would result in a reasonable detection window for urine samples collected in-competition for all genders and sport classes. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Mutagenicity of urine from individuals exposed to LPG combustion products.

    PubMed

    Yin, X J; Liu, J Z; Kong, X H; Chu, J H; Wang, H; Xiao, Z X

    1998-09-01

    The mutagenicity of urine from individuals exposed to the combustion products of liquefied petroleum gas (LPG) was detected with Salmonella typhimurium TA98 and its newly developed derivatives YG1021 (nitroreductase overproducing) and YG1024 (O-acetyltransferase overproducing). The detection showed significantly increased mutagenicity for the two YG strains and increased positive rates for all three strains in the presence of both rat liver S9 and beta-glucuronidase. Further analysis demonstrated that urine samples taken from smoking and non-smoking exposed individuals exhibited significantly higher mutagenic potency (revertants/10 microliters urine concentrate) than their corresponding controls. These results indicate that the increased urine mutagenicity is caused by the exposure to LPG combustion products or smoking. The mutagenic potency of urine samples of all exposed individuals tested with YG1024 was found to be about 7 times higher than with TA98. The difference in mutagenic potency was smaller for the same samples when comparison was made between YG1021 and TA98. This suggests that the mutagenic compounds present in the urine samples contain mainly aromatic compounds as glucuronide conjugates. Our results demonstrate that YG1024 is more sensitive than TA98 in detecting the mutagenicity of these samples. In addition, no significant difference in the mutagenic potency between the 'pure' exposed (non-smokers') and the 'pure' smokers' (unexposed) samples was found in all three tester strains. This might mean that the exposure extent of mutagens/carcinogens in LPG combustion products for exposed individuals roughly corresponds to the smoking level of smokers who smoke 20-40 cigarettes per day. Furthermore, the results also suggest that synergism might exist in the mutagenic effects of exposure to LPG combustion products and cigarette smoking.

  16. Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.

    PubMed

    Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali

    2017-09-01

    Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for the stabilization of EtG in urine samples.

  17. Rapid determination of 226Ra in emergency urine samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.

    2014-02-27

    A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed.more » The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226Ra with DGA Resin, saving time. 133Ba was used instead of 225Ra as tracer to allow immediate counting; however, 225Ra can still be used as an option. The rapid purification of 226Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226Ra, with rapid removal of isobaric interferences.« less

  18. [Validity of the assessment of urinary protein excretion by spot urine in patients with chronic kidney disease].

    PubMed

    Hayashi, Ami; Okada, Tomonari; Matsumoto, Hiroshi; Nagaoka, Yume; Wada, Toshikazu; Gondo, Asako; Nango, Tomoka; Miyaoka, Yoshitaka; Watanabe, Kanna; Iwata, Azusa; Nakao, Toshiyuki

    2013-01-01

    We investigate the validity of the assessment of urinary protein excretion by spot urine samples collected by different methods in outpatients with chronic kidney disease (CKD). SUBJECTS AND METHODS We obtained 24-hour urine and two spot urine samples, including the first morning urine and daytime urine in 159 CKD patients. Urinary protein excretion was assessed by the protein/creatinine ratio from spot urine samples (morning: m-UP (g/gCr), daytime: d-UP (g/gCr) ]. We examined the correlations and the differences among m-UP, d-UP and the actual urinary protein excretion obtained by 24-hour urine (a-UP(g/day) . Significant correlations were found between m-UP and a-UP, and between d-UP and a-UP (r = 0.88, 0.85; p < 0.001). Correlations between m-UP and a-UP were greater relative to those between d-UP and a-UP in patients with less than 3.5 g/day of a-UP and in patients with CKD stages 1 to approximately 3. The percent difference between m-UP and a-UP was--16.0 +/- 40.5%, and that between d-UP and a-UP was 27.1 +/- 72.9%. The absolute value of the percent difference between d-UP and a-UP tended to be greater than that between m-UP and a-UP (34.9 +/- 25.9% vs. 49.9 +/- 59.9%, p = 0.06). Urinary protein/creatinie ratio of the first morning urine is better approximate the urinary protein excretion obtained by 24-hour urine compared with that of spot urine in the daytime.

  19. DEVELOPMENT AND EVALUATION OF AN ENZYME-LINKED IMMUNOASSAY (ELISA) METHOD FOR THE MEASUREMENT OF 2,4-DICHLOROPHENOXYACETIC ACID IN HUMAN URINE

    EPA Science Inventory

    This paper describes the development of a 96-microwell high sample capacity ELISA method for measuring 2,4-D in urine; the analysis of 2,4-D in real-world urine samples by both ELISA and GC/MS methods; and compares the ELISA and GC/MS results in several key areas: accuracy, preci...

  20. Optimization for Peptide Sample Preparation for Urine Peptidomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan

    2014-02-25

    Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides andmore » the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.« less

  1. Evaluation of exposure to polycyclic aromatic hydrocarbons in a coke production and a graphite electrode manufacturing plant: assessment of urinary excretion of 1-hydroxypyrene as a biological indicator of exposure.

    PubMed Central

    Buchet, J P; Gennart, J P; Mercado-Calderon, F; Delavignette, J P; Cupers, L; Lauwerys, R

    1992-01-01

    OBJECTIVES--Characterisation of the airborne concentration of 13 polycyclic aromatic hydrocarbons (PAHs) at various workplaces in a graphite electrode and a coke production plant. Validation of the urinary excretion of 1-hydroxypyrene (hydroxypyrene) as a biological marker of exposure to PAH. DESIGN--Cross sectional study of workers exposed to PAHs (106 in the graphite electrode producing plant and 16 in the coke works). METHODS--Personal air sampling during at least six hours per workshift using a glass fibre filter and a Chromosorb 102 solid sorbent tube and analysis of PAHs by high performance liquid chromatography (HPLC) and spectrofluorometric detection (SFD). Collection of spot urine samples before and after the shift and analysis of 1-hydroxypyrene by HPLC and SFD. RESULTS--The workers most exposed to PAHs were those occupied at the topside area of the coke oven plant and those working in the blending and impregnation areas of the graphite electrode producing plant (mean airborne concentration of total PAHs: 199 and 223 micrograms/m3 respectively). Except for naphthalene and perylene, the relative proportion of the different PAHs did not differ between the plants. Pyrene concentration in air was highly correlated with the total airborne PAH concentration (r = 0.83, p < 0.0001) and the correlation coefficients between hydroxypyrene concentration in postshift urine samples and pyrene or total PAHs in air were 0.67 (p < 0.0001) and 0.72 (p < 0.0001) respectively. Excretion of hydroxypyrene doubled when the exposure to pyrene in air increased 10-fold. The half life for the urinary excretion of hydroxypyrene was around 18 hours (95% confidence interval 16.1-19.8). Smoking habits only explained 2.3% of the variance in hydroxypyrene excretion compared with 45% for the pyrene concentration in air. CONCLUSION--The determination of the urinary excretion of hydroxypyrene in postshift urine samples can be used as a suitable biomarker to assess individual exposure to PAHs in coke ovens and in graphite electrode manufacturing plants. PMID:1463676

  2. Assessment of Occupational Exposure to Bisphenol A in Five Different Production Companies in Finland.

    PubMed

    Heinälä, Milla; Ylinen, Katriina; Tuomi, Tapani; Santonen, Tiina; Porras, Simo P

    2017-01-01

    The aim of the study was to assess occupational exposure to bisphenol A in Finland. Five companies took part in the research project: two paint factories (liquid and powder paints), a composite product factory, a thermal paper factory, and a tractor factory. Exposure was assessed by measuring total bisphenol A excretion (free and conjugated) from urine samples, and its concentrations in the air. The results revealed the specific work tasks in two of five companies in which significant occupational exposure to bisphenol A may occur. In the manufacturing of liquid paint hardener, urine samples collected after the working day showed bisphenol A levels of up to 100-170 µg l-1. Workers in thermal paper manufacturing were also exposed to bisphenol A, especially those working in the manufacture of coating material and operating coating machines. Median concentrations of the post-shift urine samples of coating machine workers were in the range of 130-250 µg l-1. The highest bisphenol A concentrations were in the range of 1000-1500 µg l-1. Recommendations for more effective personal protection resulted in decreased exposure, particularly among coating machine operators. In the rest of the companies, urinary bisphenol A levels were typically in the range of those of the general population. Bisphenol A concentrations in air samples were typically low (<40 µg m-3), except in some short-term duties related to the handling of solid bisphenol A (maximum 17.6 mg m-3). Low air levels, even in the companies with high urinary levels, suggest exposure via dermal contact. According to the results, exposure to bisphenol A may occur particularly in work tasks that involve the use of pure bisphenol A. In these tasks, special attention should be paid to the prevention of skin exposure. Inhalation exposure may become relevant in dusty work tasks. Since skin exposure is of potential concern in these tasks, biomonitoring is recommended as the method for assessing occupational exposure to bisphenol A. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  3. Hair and urine testing to assess drugs of abuse consumption in couples undergoing assisted reproductive technology (ART).

    PubMed

    Pichini, Simona; De Luca, Roberto; Pellegrini, Manuela; Marchei, Emilia; Rotolo, Maria Concetta; Spoletini, Roberta; D'Aloja, Paola; Pacifici, Roberta; Mortali, Claudia; Scaravelli, Giulia

    2012-05-10

    For the first time in Europe hair and urine testing have been applied to assess drugs of abuse consumption in couples undergoing assisted reproductive technology and the eventual association of toxic habits with other lifestyle, health status and sociodemographic factors was also investigated. Couples attending five assisted reproduction centers in Rome were invited to join the study. When they presented at the Centre for the visit, they were asked to answer a structured questionnaire concerning sociodemographic characteristics and lifestyle habits, and at the same time to provide hair and urine samples. Hair and urine testing for drugs of abuse, urinary profile of principal endogenous steroids involved in fertility process (testosterone, epitestosterone, androsterone, etiocholanolone and dehydroepiandrosterone) and of alcohol and tobacco smoke biomarkers were performed with validated methodologies. Of the 594 enrolled individuals (297 couples), 352 (164 couples and 24 single individuals from the couple) completed the questionnaire and gave both hair and urine samples, apart from 3 bald men, who only gave urine samples. Urine testing showed an overall 4.8% (17 individuals) positivity to drugs of abuse: 4.2% to cannabinoids, 1.4% to cocaine and 0.85% to both drugs. Results of 4cm segment hair samples testing matched those from urine samples. Thus, taking together, results of urine and hair testing confirmed repeated use of cannabis, cocaine and both drugs in 3.7, 0.85 and 0.57% examined individuals, respectively. Drug consumers were in a statistically higher percentage active smokers and alcohol drinkers, less prone to physical activity and with a trend towards higher weight than non consumers. Finally, repeated drug consumption was associated with significant lower concentration of urinary testosterone in males and of urinary dehydroepiandrosterone in females. The findings of the present study confirm the suitability of urine testing to disclose recent drugs of abuse consumption and of hair analysis to verify repeated consumption. Association between different toxic habits and sedentary lifestyle is also substantiated by the obtained results in our cohort of couples attending assisted reproduction centers. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. Hollow-fiber-supported liquid phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for determination of chlorophenols in human urine samples.

    PubMed

    Ito, Rie; Kawaguchi, Migaku; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Sakui, Norihiro; Saito, Koichi; Nakazawa, Hiroyuki

    2008-09-01

    A simple and highly sensitive method that involves hollow-fiber-supported liquid phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) was developed for the determination of chlorophenols (CPs) such as 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TrCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) in human urine samples. Human urine samples were enzymatically de-conjugated with beta-glucuronidase and sulfatase. After de-conjugation, HF-LPME with in situ derivatization was performed. After extraction, 2 microl of extract was carefully withdrawn into a syringe and injected into the GC-MS system. The limits of detection (S/N=3) and quantification (S/N>10) of CPs in the human urine samples are 0.1-0.2 ng ml(-1) and 0.5-1 ng ml(-1), respectively. The calibration curve for CPs is linear with a correlation coefficient of >0.99 in the range of 0.5-500 ng ml(-1) for DCP and TrCP, and of 1-500 ng ml(-1) for TeCP and PCP, respectively. The average recoveries of CPs (n=6) in human urine samples are 81.0-104.0% (R.S.D.: 1.9-6.6%) with correction using added surrogate standards. When the proposed method was applied to human urine samples, CPs were detected at sub-ng ml(-1) level.

  5. Simultaneous immunostaining with anti-S100P and anti-SV40 antibodies revealed the origin of BK virus-infected decoy cells in voided urine samples.

    PubMed

    Ariyasu, S; Yanai, H; Sato, M; Shinno, Y; Taniguchi, K; Yamadori, I; Miki, Y; Sato, Y; Yoshino, T; Takahashi, K

    2015-08-01

    Methods for determining the origin of BK virus (BKV)-infected cells (decoy cells) in clinical urine samples have not been established although they could enhance the diagnosis of BKV infection in immunocompromised patients. We performed simultaneous immunostaining with anti-S100P (a urothelial marker) and anti-SV40 antibodies in 66 clinical urine samples exhibiting SV40 positivity and a decoy-cell appearance on Papanicolaou staining. The clinical voided urine samples included seven cases of renal transplantation, 47 cases of cancer therapy and 12 cases of non-neoplastic disease. SurePath(™) liquid-based cytology was used for the urine samples. BKV-infected cells were categorized as SV40(+)/S100P(+) and SV40 (+)/S100p(-). SV40(+)/S100P(-) cells were found in 55 cases (83.4%); nine cases (13.6%) carried both SV40(+)/S100P(-) and SV40(+)/S100P(+) cells. The former were identified as BKV infection in renal tubules and the latter in both the renal tubules and urothelial epithelia. The remaining two cases (3.0%) had only SV40(+)/S100P(+) cells of urothelial origin. Simultaneous immunostaining with anti-S100P and anti-SV40 is a useful method for determining the origin of BKV-infected cells in clinical urine samples from immunocompromised patients such as renal transplantation recipients. © 2014 John Wiley & Sons Ltd.

  6. A prototype urine collection device for female aircrew

    NASA Technical Reports Server (NTRS)

    Bisson, Roger U.; Delger, Karlyna L.

    1993-01-01

    Women are gaining increased access to small military cockpits. This shift has stimulated the search for practical urine containment and disposal methods for female aircrew. There are no external urine collection devices (UCD) for women that are comfortable, convenient, and leak free. We describe a prototype UCD that begins to meet this need. Materials used to make custom aviator masks were adapted to mold a perineal mask. First, a perineal cast (negative) was used to make a mold (positive). Next, a perineal mask made of wax was formed to fit the positive mold. Finally, a soft, pliable perineal mask was fabricated using the wax model as a guide. The prototype was tested for comfort, fit, and leakage. In the sitting position, less than 5 cc of urine leakage occurred with each 600 cc of urine collected. Comfort was mostly satisfactory, but ambulation was limited and the outlet design could lead to kinking and obstruction. We concluded that a perineal mask may serve as a comfortable and functional external UCD acceptable for use by females in confined environments. Changes are needed to improve comfort, fit, and urine drainage. Integration into cockpits, pressure suits, chemical defense gear, and environments where access to relief facilities is restricted is planned.

  7. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting.

    PubMed

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer(®) Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible.

  8. Validation of a urine color scale for assessment of urine osmolality in healthy children.

    PubMed

    Kavouras, Stavros A; Johnson, Evan C; Bougatsas, Dimitris; Arnaoutis, Giannis; Panagiotakos, Demosthenes B; Perrier, Erica; Klein, Alexis

    2016-04-01

    Urine color (UC) is a practical tool for hydration assessment. The technique has been validated in adults, but has not been tested in children. The purpose of the study was to test the validity of the urine color scale in young, healthy boys and girls, as a marker of urine concentration, investigate its diagnostic ability of detecting hypohydration and examine the ability of children to self-assess UC. A total of 210 children participated (age: 8-14 years, body mass: 43.4 ± 12.6 kg, height: 1.49 ± 0.13 m, body fat: 25.2 ± 7.8 %). Data collection included: two single urine samples (first morning and before lunch) and 24-h sampling. Hydration status was assessed via urine osmolality (UOsmo) and UC via the eight-point color scale. Mean UC was 3 ± 1 and UOsmo 686 ± 223 mmol kg(-1). UC displayed a positive relationship as a predictor of UOsmo (R (2): 0.45, P < 0.001). Based on the receiver operating curve, UC has good overall classification ability for the three samples (area under the curve 85-92 %), with good sensitivity (92-98 %) and specificity (55-68 %) for detecting hypohydration. The overall accuracy of the self-assessment of UC in the morning or the noon samples ranged from 67 to 78 %. Further threshold analysis indicated that the optimal self-assessed UC threshold for hypohydration was ≥4. The classical eight-point urine color scale is a valid method to assess hydration in children of age 8-14 years, either by researchers or self-assessment.

  9. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy.

    PubMed

    Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.

  10. Analysis of the variability of human normal urine by 2D-GE reveals a "public" and a "private" proteome.

    PubMed

    Molina, Laurence; Salvetat, Nicolas; Ameur, Randa Ben; Peres, Sabine; Sommerer, Nicolas; Jarraya, Fayçal; Ayadi, Hammadi; Molina, Franck; Granier, Claude

    2011-12-10

    The characterization of the normal urinary proteome is steadily progressing and represents a major interest in the assessment of clinical urinary biomarkers. To estimate quantitatively the variability of the normal urinary proteome, urines of 20 healthy people were collected. We first evaluated the impact of the sample conservation temperature on urine proteome integrity. Keeping the urine sample at RT or at +4°C until storage at -80°C seems the best way for long-term storage of samples for 2D-GE analysis. The quantitative variability of the normal urinary proteome was estimated on the 20 urines mapped by 2D-GE. The occurrence of the 910 identified spots was analysed throughout the gels and represented in a virtual 2D gel. Sixteen percent of the spots were found to occur in all samples and 23% occurred in at least 90% of urines. About 13% of the protein spots were present only in 10% or less of the samples, thus representing the most variable part of the normal urinary proteome. Twenty proteins corresponding to a fraction of the fully conserved spots were identified by mass spectrometry. In conclusion, a "public" urinary proteome, common to healthy individuals, seems to coexist with a "private" urinary proteome, which is more specific to each individual. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Cytotoxic drug residues in urine of dogs receiving anticancer chemotherapy.

    PubMed

    Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D

    2010-01-01

    The presence of cytotoxic drug residues in urine of dogs may represent an exposure risk for pet owners and other people as well as a potential environmental contaminant. However, studies on cytotoxic drug residues in excretions of clinical patients are lacking in veterinary oncology. Variable concentrations of cytotoxic residues are present in urine samples, depending on sampling time and substance. Client-owned dogs with lymphoma or mast cell tumors treated with standard chemotherapy protocols. Urine samples were collected before, directly after, and on days after administration of chemotherapy. Measurement of vincristine, vinblastine, cyclophosphamide, and doxorubicin residues in canine urine was performed by a quantitative liquid chromatography tandem mass spectrometry (LC/MS/MS) method. Median cyclophosphamide residue concentration was 398.2 microg/L directly after treatment (d0) and was below the level of detection on days 1-3 (d1, d2, d3). Median vincristine residue concentration was 53.8 microg/L directly after treatment and was 20.2, 11.4, and 6.6 microg/L on days 1, 2, and 3. Median vinblastine residues were 144.9 (d0), 70.8 (d1), 35.6 (d2), and 18.7 microg/L (d3) with low concentrations detectable for 7 days after treatment. Median urine doxorubicin concentrations were 354.0 (d0), 165.6 (d1), 156.9 (d2), and 158.2 microg/L (d3). Low concentrations of doxorubicin were measurable up to 21 days after administration. Variable concentrations of chemotherapeutics were measured in urine samples, depending on sampling time point and drug. Findings may inform current chemoprotection guidelines and help minimize exposure risks.

  12. Prednisolone and prednisone neo-formation in bovine urine after sampling.

    PubMed

    Arioli, F; Casati, A; Fidani, M; Silvestri, M; Pompa, G

    2012-06-01

    The rise in the frequency of detecting prednisolone in bovine urine from northern Italy has come into focus of attention in recent years. The possibility that neo-formation of prednisolone or that prednisone may occur in urine after collection of samples was therefore investigated. Cow urine collected for official routine controls in Lombardy containing more than 80 ng/ml cortisol, and prednisolone and prednisone below the decision limit (CCα) of the method (0.4 and 0.5 ng/ml, respectively) was used. The C1-2 dehydrogenation of naturally present cortisol and cortisone was checked by incubating urine, both contaminated and uncontaminated with faeces, at 37°C and by collecting samples at 0, 1, 2, 4, 6 and 24 h. The influence of Helix pomatia juice was also investigated in order to determine whether deconjugation could influence the reliability of the results. All samples were analysed by HPLC-MS3 for the presence of cortisol, cortisone, prednisolone and prednisone in negative electrospray ionisation mode, utilising the consecutive reaction monitoring of product ions derived from the formate molecular adduct ([M+HCOO]-). The observed neo-formation of prednisolone shows that inappropriate temperatures in sample storage and processing can result in an incorrect accusation of non-compliance. The faecal contamination of urine, performed with the aim to mimic a collection conducted without the necessary care, moreover, evoked a high increase in prednisolone concentration in two out of seven animals. Moreover, H. pomatia juice had no significant effect on the prednisolone concentration, indicating that this corticosteroid is present in its free form in cow urine.

  13. Determination of total concentration of chemically labeled metabolites as a means of metabolome sample normalization and sample loading optimization in mass spectrometry-based metabolomics.

    PubMed

    Wu, Yiman; Li, Liang

    2012-12-18

    For mass spectrometry (MS)-based metabolomics, it is important to use the same amount of starting materials from each sample to compare the metabolome changes in two or more comparative samples. Unfortunately, for biological samples, the total amount or concentration of metabolites is difficult to determine. In this work, we report a general approach of determining the total concentration of metabolites based on the use of chemical labeling to attach a UV absorbent to the metabolites to be analyzed, followed by rapid step-gradient liquid chromatography (LC) UV detection of the labeled metabolites. It is shown that quantification of the total labeled analytes in a biological sample facilitates the preparation of an appropriate amount of starting materials for MS analysis as well as the optimization of the sample loading amount to a mass spectrometer for achieving optimal detectability. As an example, dansylation chemistry was used to label the amine- and phenol-containing metabolites in human urine samples. LC-UV quantification of the labeled metabolites could be optimally performed at the detection wavelength of 338 nm. A calibration curve established from the analysis of a mixture of 17 labeled amino acid standards was found to have the same slope as that from the analysis of the labeled urinary metabolites, suggesting that the labeled amino acid standard calibration curve could be used to determine the total concentration of the labeled urinary metabolites. A workflow incorporating this LC-UV metabolite quantification strategy was then developed in which all individual urine samples were first labeled with (12)C-dansylation and the concentration of each sample was determined by LC-UV. The volumes of urine samples taken for producing the pooled urine standard were adjusted to ensure an equal amount of labeled urine metabolites from each sample was used for the pooling. The pooled urine standard was then labeled with (13)C-dansylation. Equal amounts of the (12)C-labeled individual sample and the (13)C-labeled pooled urine standard were mixed for LC-MS analysis. This way of concentration normalization among different samples with varying concentrations of total metabolites was found to be critical for generating reliable metabolome profiles for comparison.

  14. Direct detection of hyaluronidase in urine using cationic gold nanoparticles: a potential diagnostic test for bladder cancer.

    PubMed

    Nossier, Ahmed Ibrahim; Eissa, Sanaa; Ismail, Manal Fouad; Hamdy, Mohamed Ahmed; Azzazy, Hassan Mohamed El-Said

    2014-04-15

    Hyaluronidase (HAase) was reported as a urinary marker of bladder cancer. In this study, a simple colorimetric gold nanoparticle (AuNP) assay was developed for rapid and sensitive detection of urinary HAase activity. Charge interaction between polyanionic hyaluronic acid (HA) and cationic AuNPs stabilized with cetyl trimethyl ammonium bromide (CTAB) led to formation of gold aggregates and a red to blue color shift. HAase digests HA into small fragments preventing the aggregation of cationic AuNPs. The nonspecific aggregation of AuNPs in urine samples was overcome by pre-treatment of samples with the polycationic chitosan that was able to agglomerate all negatively charged interfering moieties before performing the assay. The developed AuNP assay was compared with zymography for qualitative detection of urinary HAase activity in 40 bladder carcinoma patients, 11 benign bladder lesions patients and 15 normal individuals, the assay sensitivity was 82.5% vs. 65% for zymography, while the specificity for both assays was 96.1%. The absorption ratio, A530/A620 of the reacted AuNP solution was used to quantify the HAase activity. The best cut off value was 93.5 μU/ng protein, at which the sensitivity was 90% and the specificity was 80.8%.The developed colorimetric AuNP HAase assay is simple, inexpensive, and can aid noninvasive diagnosis of bladder cancer. © 2013 Elsevier B.V. All rights reserved.

  15. Impedimetric method for measuring ultra-low E. coli concentrations in human urine.

    PubMed

    Settu, Kalpana; Chen, Ching-Jung; Liu, Jen-Tsai; Chen, Chien-Lung; Tsai, Jang-Zern

    2015-04-15

    In this study, we developed an interdigitated gold microelectrode-based impedance sensor to detect Escherichia coli (E. coli) in human urine samples for urinary tract infection (UTI) diagnosis. E. coli growth in human urine samples was successfully monitored during a 12-h culture, and the results showed that the maximum relative changes could be measured at 10Hz. An equivalent electrical circuit model was used for evaluating the variations in impedance characteristics of bacterial growth. The equivalent circuit analysis indicated that the change in impedance values at low frequencies was caused by double layer capacitance due to bacterial attachment and formation of biofilm on electrode surface in urine. A linear relationship between the impedance change and initial E. coli concentration was obtained with the coefficient of determination R(2)>0.90 at various growth times of 1, 3, 5, 7, 9 and 12h in urine. Thus our sensor is capable of detecting a wide range of E. coli concentration, 7×10(0) to 7×10(8) cells/ml, in urine samples with high sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Astronaut Bones: Stable Calcium Isotopes in Urine as a Biomarker of Bone Mineral Balance

    NASA Astrophysics Data System (ADS)

    Skulan, J.; Gordon, G. W.; Romaniello, S. J.; Anbar, A. D.; Smith, S. M.; Zwart, S.

    2016-12-01

    Bone loss is a common health concern, in conditions ranging from osteoporosis to cancer. Bone loss due to unloading is also an important health issue for astronauts. We demonstrate stable calcium isotopes, a tool developed in geochemistry, are capable of detecting real-time quantitative changes in net bone mineral balance (BMB) using serum and urine [1]. We validated this technique by comparing with DEXA and biomarker data in subjects during bed rest, a ground-based analog of space flight effects [2-4]. We now apply this tool to assess changes in astronauts' BMB before, during and after 4-6 month space missions. There is stable isotope fractionation asymmetry between bone formation and resorption. During bone formation there is a mass-dependent preference for "lighter" calcium isotopes to be removed from serum and incorporated into bone mineral. During bone resorption, there is no measurable isotopic discrimination between serum and bone. Hence, when bone formation rates exceed that of resorption, serum and urine become isotopically "heavy" due to the sequestration of "light" calcium in bone. Conversely, when bone resorption exceeds bone formation, serum and urine become isotopically "light" due to the release of the sequestered light calcium from bone. We measured Ca isotopes in urine of thirty International Space Station astronauts. Average Ca isotope values in astronauts' urine shift isotopically lighter during microgravity, consistent with negative net BMB. Within a month of return to Earth, astronauts returned to within error of their δ44Ca value prior to departure. Urine samples from astronauts testing bone loss countermeasures showed bisphosphonates provide a viable pharmacological countermeasure. Some, but not all, individuals appear able to resist bone loss through diet and intensive resistive exercise alone. This is a promising new technique for monitoring BMB in astronauts, and hopefully someday on the way to/from Mars, this also has important clinical applications for human health and terrestrial medicine [5]. REFERENCES [1] Morgan, J.L. et al (2011) Anal Chem 83, 6956-6962. [2] Skulan, J.L. et al. (2007) Clin Chem 53, 1155-1158. [3] Morgan, J.L. et al (2012) PNAS 109, 9989-9994. [4] Channon, M.B. et al (2015) Bone 77, 69-74. [5] Gordon, G.W. et al (2014) Leukemia 28, 2112-2115.

  17. Rapid microbiological screening for tuberculosis in HIV-positive patients on the first day of acute hospital admission by systematic testing of urine samples using Xpert MTB/RIF: a prospective cohort in South Africa.

    PubMed

    Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; van Wyk, Gavin; Vogt, Monica; Pahlana, Pearl; Nicol, Mark P; Meintjes, Graeme

    2015-08-14

    Autopsy studies of HIV/AIDS-related hospital deaths in sub-Saharan Africa reveal frequent failure of pre-mortem diagnosis of tuberculosis (TB), which is found in 34-64 % of adult cadavers. We determined the overall prevalence and predictors of TB among consecutive unselected HIV-positive adults requiring acute hospital admission and the comparative diagnostic yield obtained by screening urine and sputum samples obtained on day 1 of admission with Xpert MTB/RIF (Xpert). To determine overall TB prevalence accurately, comprehensive clinical sampling (sputum, urine, blood plus other relevant samples) was done and TB was defined by detection of Mycobacterium tuberculosis in any sample using Xpert and/or mycobacterial liquid culture. To evaluate a rapid screening strategy, we compared the diagnostic yield of Xpert testing sputum samples and urine samples obtained with assistance from a respiratory study nurse in the first 24 h of admission. Unselected HIV-positive acute adult new medical admissions (n = 427) who were not receiving TB treatment were enrolled irrespective of clinical presentation or symptom profile. From 2,391 cultures and Xpert tests done (mean, 5.6 tests/patient) on 1,745 samples (mean, 4.1 samples/patient), TB was diagnosed in 139 patients (median CD4 cell count, 80 cells/μL). TB prevalence was very high (32.6 %; 95 % CI, 28.1-37.2 %; 139/427). However, patient symptoms and risk factors were poorly predictive for TB. Overall, ≥1 non-respiratory sample(s) tested positive in 115/139 (83 %) of all TB cases, including positive blood cultures in 41/139 (29.5 %) of TB cases. In the first 24 h of admission, sputum (spot and/or induced samples) and urine were obtainable from 37.0 % and 99.5 % of patients, respectively (P <0.001). From these, the proportions of total TB cases (n = 139) that were diagnosed by Xpert testing sputum, urine or both sputum and urine combined within the first 24 h were 39/139 (28.1 %), 89/139 (64.0 %) and 108/139 (77.7 %) cases, respectively (P <0.001). The very high prevalence of active TB and its non-specific presentation strongly suggest the need for routine microbiological screening for TB in all HIV-positive medical admissions in high-burden settings. The incremental diagnostic yield from Xpert testing urine was very high and this strategy might be used to rapidly screen new admissions, especially if sputum is difficult to obtain.

  18. An investigation of the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid in authentic urine samples.

    PubMed

    Skopp, Gisela; Pötsch, Lucia

    2004-01-01

    Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied using spiked urine to elucidate the results obtained from authentic samples. In authentic urine samples, the initial pH ranged from 5.1 to 8.8. The glucuronide was found to be highly labile at a storage temperature of 4 degrees C and above. Initially, 18 urine samples tested positive for THCCOOH. After 2 days storage at 20 degrees C, THCCOOH was detectable in a further 4 samples, and 7 more samples tested positive for THCCOOH (5-81 ng/mL) after 15 days. Depending on time and temperature, the glucuronide concentration decreased, resulting in an increase of THCCOOH concentration. However, a loss in mean total THCCOOH concentration was found, which was significantly higher in deteriorated samples than in samples without signs of deterioration after 15 days of storage at 20 degrees C. In the drug-free urine sample separately spiked with THCCOOglu or THCCOOH, the investigations on the stability of the target analytes at various pH values revealed that THCCOOH was stable at pH 5.0. At higher pH values, its concentration slightly decreased with time, and about 69% of the initial THCCOOH concentration was still present at pH 8.0 on day 5. THCCOOglu concentrations rapidly decreased with increasing pH value. For example, only 72% of the initial THCCOOglu concentration could be detected at pH 5.0 on day 1. Degradation of the glucuronide resulted in formation of THCCOOH, which was observed even at pH 5.0. In light of the present findings, advanced forensic interpretations based on the presence of THCCOOH or the pattern of THCCOOH and THCCOOglu in stored urine samples seems questionable.

  19. The simultaneous detection of trivalent & hexavalent chromium in exhaled breath condensate: A feasibility study comparing workers and controls.

    PubMed

    Leese, Elizabeth; Morton, Jackie; Gardiner, Philip H E; Carolan, Vikki A

    2017-04-01

    The analytical method outlined in this feasibility study has been used to show that trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) can be detected and measured in exhaled breath condensate (EBC) samples. EBC samples and urine samples were collected from a cohort of 58 workers occupationally exposed to hexavalent chromium compounds and 22 unexposed volunteers (control group). Levels of Cr(III) and Cr(VI) were determined in EBC samples and total chromium levels were determined in urine samples. Pre and post working week samples for both EBC and urine were collected in tandem. Total chromium in urine samples was analysed by inductively coupled plasma mass spectrometry (ICP-MS). Analysis of Cr(III) and Cr(VI) in EBC samples used a hyphenated micro liquid chromatography (μLC) system coupled to an ICP-MS. Separation was achieved using an anion exchange micro-sized column. The results showed that the occupationally exposed workers had significantly higher levels of Cr(III) and Cr(VI) in their EBC samples than the control group, as well as higher levels of total chromium in their urine samples. However, for the exposed workers no significant difference was found between pre and post working week EBC samples for either Cr(III) or Cr(VI). This study has established that Cr(III) and Cr(VI) can simultaneously be detected and measured in 'real' EBC samples and will help in understanding inhalation exposure. Crown Copyright © 2016. Published by Elsevier GmbH. All rights reserved.

  20. Electrical conductivity and total dissolved solids in urine.

    PubMed

    Fazil Marickar, Y M

    2010-08-01

    The objective of this paper is to study the relevance of electrical conductivity (EC) and total dissolved solids (TDS) in early morning and random samples of urine of urinary stone patients; 2,000 urine samples were studied. The two parameters were correlated with the extent of various urinary concrements. The early morning urine (EMU) and random samples of the patients who attended the urinary stone clinic were analysed routinely. The pH, specific gravity, EC, TDS, redox potential, albumin, sugar and microscopic study of the urinary sediments including red blood cells (RBC), pus cells (PC), crystals, namely calcium oxalate monohydrate (COM), calcium oxalate dihydrate (COD), uric acid (UA), and phosphates and epithelial cells were assessed. The extent of RBC, PC, COM, COD, UA and phosphates was correlated with EC and TDS. The values of EC ranged from 1.1 to 33.9 mS, the mean value being 21.5 mS. TDS ranged from 3,028 to 18,480 ppm, the mean value being 7,012 ppm. The TDS levels corresponded with EC of urine. Both values were significantly higher (P < 0.05) in the EMU samples than the random samples. There was a statistically significant correlation between the level of abnormality in the urinary deposits (r = +0.27, P < 0.05). In samples, where the TDS were more than 12,000 ppm, there were more crystals than those samples containing TDS less than 12,000 ppm. However, there were certain urine samples, where the TDS were over 12,000, which did not contain any urinary crystals. It is concluded that the value of TDS has relevance in the process of stone formation.

  1. Concentrations of delta9-tetrahydrocannabinol and 11-nor-9-carboxytetrahydrocannabinol in blood and urine after passive exposure to Cannabis smoke in a coffee shop.

    PubMed

    Röhrich, J; Schimmel, I; Zörntlein, S; Becker, J; Drobnik, S; Kaufmann, T; Kuntz, V; Urban, R

    2010-05-01

    Cannabinoid concentrations in blood and urine after passive exposure to cannabis smoke under real-life conditions were investigated in this study. Eight healthy volunteers were exposed to cannabis smoke for 3 h in a well-attended coffee shop in Maastricht, Netherlands. An initial blood and urine sample was taken from each volunteer before exposure. Blood samples were taken 1.5, 3.5, 6, and 14 h after start of initial exposure, and urine samples were taken after 3.5, 6, 14, 36, 60, and 84 h. The samples were subjected to immunoassay screening for cannabinoids and analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol (THC), 11-nor-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH), and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH). It could be demonstrated that all volunteers absorbed THC. However, the detected concentrations were rather small. None of the urine samples produced immunoassay results above the cutoff concentration of 25 ng/mL. THC-COOH concentrations up to 5.0 and 7.8 ng/mL before and after hydrolysis, respectively, were found in the quantitative GC-MS analysis of urine. THC could be detected in trace amounts close to the detection limit of the used method in the first two blood samples after initial exposure (1.5 and 3.5 h). In the 6 h blood samples, THC was not detectable anymore. THC-COOH could be detected after 1.5 h and was still found in 3 out of 8 blood samples after 14 h in concentrations between 0.5 and 1.0 ng/mL.

  2. Stability of Zika virus in urine: Specimen processing considerations and implications for the detection of RNA targets in urine.

    PubMed

    Tan, Susanna K; Sahoo, Malaya K; Milligan, Stephen B; Taylor, Nathaniel; Pinsky, Benjamin A

    2017-10-01

    Detection of Zika virus (ZIKV) RNA in urine is of increasing interest for the diagnosis of ZIKV infection. Pre-analytical variables can significantly impact the stability of RNA in urine. To determine optimal specimen processing protocols that would maximize detection of ZIKV RNA in urine by real-time, reverse transcriptase PCR, we investigated the effect of temperature, initial ZIKV concentration, use of nucleic acid stabilizers, and time on ZIKV RNA levels. Urine samples from healthy donors were spiked with ZIKV using the Exact Diagnostics ® ZIKV Verification Panel, a commercially available panel composed of heat-inactivated ZIKV, at concentrations of 5.0 log 10 copies/mL (ZIKV-high) and 4.0 log 10 copies/mL (ZIKV-low). Samples were stored at room temperature, 4°C, or -80°C and frozen aliquots were exposed to no stabilizer (urine), Buffer ATL (Qiagen, Germantown, MD), or DNA/RNA Shield (Zymo Research, Irvine, CA). ZIKV RNA levels in urine declined steadily at room temperature, though was not significant by 48h (ZIKV-high, p=0.09; ZIKV-low, p=0.20). ZIKV RNA titers were consistently higher when stored at 4°C, suggesting that storage at 4°C can slow the progression of RNA degradation. Freezing urine samples at -80°C resulted in a significant loss of detectable ZIKV RNA in the ZIKV-low group. ZIKV RNA was detected in 5/6 replicates at 3days, 1/6 replicates at 10days, and 1/3 replicates at 30days, with findings reproducible on repeat testing. Presence of either nucleic acid stabilizer in urine corrected this effect, and resulted in recovery of ZIKV RNA in all replicates. Use of a nucleic acid stabilizer in the ZIKV-high group did not add incremental benefit for the detection or quantitation of ZIKV RNA. ZIKV RNA is prone to degradation in urine with loss of detectable virus even when specimens are frozen at -80°C for 10days. Detection of ZIKV-positive urine samples, particularly those containing low ZIKV titers may be aided with the addition of a nucleic acid stabilizer during urine specimen processing. Copyright © 2017. Published by Elsevier B.V.

  3. Spectrophotometric determination of paracetamol in urine with tetrahydroxycalix[4]arene as a coupling reagent and preconcentration with triton X-114 using cloud point extraction.

    PubMed

    Filik, Hayati; Sener, Izzet; Cekiç, Sema Demirci; Kiliç, Emine; Apak, Reşat

    2006-06-01

    In the present paper, conventional spectrophotometry in conjunction with cloud point extraction-preconcentration were investigated as alternative methods for paracetamol (PCT) assay in urine samples. Cloud point extraction (CPE) was employed for the preconcentration of p-aminophenol (PAP) prior to spectrophotometric determination using the non-ionic surfactant Triton X-114 (TX-114) as an extractant. The developed methods were based on acidic hydrolysis of PCT to PAP, which reacted at room temperature with 25,26,27,28-tetrahydroxycalix[4]arene (CAL4) in the presence of an oxidant (KIO(4)) to form an blue colored product. The PAP-CAL4 blue dye formed was subsequently entrapped in the surfactant micelles of Triton X-114. Cloud point phase separation with the aid of Triton X-114 induced by addition of Na(2)SO(4) solution was performed at room temperature as an advantage over other CPE assays requiring elevated temperatures. The 580 nm-absorbance maximum of the formed product was shifted bathochromically to 590 nm with CPE. The working range of 1.5-12 microg ml(-1) achieved by conventional spectrophotometry was reduced down to 0.14-1.5 microg ml(-1) with cloud point extraction, which was lower than those of most literature flow-through assays that also suffer from nonspecific absorption in the UV region. By preconcentrating 10 ml sample solution, a detection limit as low as 40.0 ng ml(-1) was obtained after a single-step extraction, achieving a preconcentration factor of 10. The stoichiometric composition of the dye was found to be 1 : 4 (PAP : CAL4). The impact of a number of parameters such as concentrations of CAL4, KIO(4), Triton X-100 (TX-100), and TX-114, extraction temperature, time periods for incubation and centrifugation, and sample volume were investigated in detail. The determination of PAP in the presence of paracetamol in micellar systems under these conditions is limited. The established procedures were successfully adopted for the determination of PCT in urine samples. Since the drug is rapidly absorbed and excreted largely in urine and its high doses have been associated with lethal hepatic necrosis and renal failure, development of a rapid, sensitive and selective assay of PCT is of vital importance for fast urinary screening and antidote administration before applying more sophisticated, but costly and laborious hyphenated instrumental techniques of HPLC-SPE-NMR-MS.

  4. Predicting Patients with Inadequate 24- or 48-Hour Urine Collections at Time of Metabolic Stone Evaluation.

    PubMed

    McGuire, Barry B; Bhanji, Yasin; Sharma, Vidit; Frainey, Brendan T; McClean, Megan; Dong, Caroline; Rimar, Kalen; Perry, Kent T; Nadler, Robert B

    2015-06-01

    We aimed to understand the characteristics of patients who are less likely to submit adequate urine collections at metabolic stone evaluation. Inadequate urine collection was defined using two definitions: (1) Reference ranges for 24-hour creatinine/kilogram (Cr/24) and (2) discrepancy in total 24-hour urine Cr between 24-hour urine collections. There were 1502 patients with ≥1 kidney stone between 1998 and 2014 who performed a 24- or 48-hour urine collection at Northwestern Memorial Hospital and who were identified retrospectively. Multivariate analysis was performed to analyze predictor variables for adequate urine collection. A total of 2852 urine collections were analyzed. Mean age for males was 54.4 years (range 17-86), and for females was 50.2 years (range 8-90). One patient in the study was younger than 17 years old. (1) Analysis based on the Cr 24/kg definition: There were 50.7% of patients who supplied an inadequate sample. Females were nearly 50% less likely to supply an adequate sample compared with men, P<0.001. Diabetes (odds ratio [OR] 1.42 [1.04-1.94], P=0.026) and vitamin D supplementation (OR 0.64 [0.43-0.95], P=0.028) predicted receiving an adequate/inadequate sample, respectively. (2) Analysis based on differences between total urinary Cr: The model was stratified based on percentage differences between samples up to 50%. At 10%, 20%, 30%, 40%, and 50% differences, inadequate collections were achieved in 82.8%, 66.9%, 51.7%, 38.5%, and 26.4% of patients, respectively. Statistical significance was observed based on differences of ≥40%, and this was defined as the threshold for an inadequate sample. Female sex (OR 0.73 [0.54-0.98], P=0.037) predicted supplying inadequate samples. Adequate collections were more likely to be received on a Sunday (OR 1.6 [1.03-2.58], P=0.038) and by sedentary workers (OR 2.3 [1.12-4.72], P=0.023). Urine collections from patients during metabolic evaluation for nephrolithiasis may be considered inadequate based on two commonly used clinical definitions. This may have therapeutic or economic ramifications and the propensity for females to supply inadequate samples should be investigated further.

  5. Short-term emissions of ammonia and carbon dioxide from cattle urine contaminated tropical grassland microcosm.

    PubMed

    Majumdar, Deepanjan; Patel, Manoj; Drabar, Reena; Vyas, Manish

    2006-11-01

    The study was designed to understand the emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) from a single cattle urination event on a tropical grassland and underline the significance of the emissions in the context of huge animal population grazing on large pasture areas in some countries. Emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) were monitored for three weeks from a tropical grassland (dominated by Cynodon dactylon Pers.) microcosm contaminated with cow and buffalo urine. The grassland microcosms were treated with urine (50 and 100 ml of each) only once and irrigated with water once every week. Ammonia was sampled by an automatic sampling system comprising of a vacuum pump, three-way stopcocks and rubber tubing and an impinger containing suitable absorbing solution (H(2)SO(4)), connected to the tubing suitably. The sampled gas, after sucked by the vacuum pump and absorbed in H(2)SO(4), was allowed to enter the closed microcosm again maintaining internal pressure of the microcosm. Carbon dioxide was sampled by absorption in an alkali (NaOH) trap inside the microcosm. Both NH(3) and CO(2) emissions were highly variable temporally and there was no continuous increasing or decreasing emission trend with time. Respectively, 45 and 46% of total NH(3)-N were emitted within first 48 h from 50 and 100 ml cow urine application while the corresponding values for buffalo urine were 34 and 32%. Total NH(3)-N emissions, integrated for sampling days (i.e. 1, 2, 3, 4, 6, 15, 18 and 21st) were 11 and 6% in cow and 8 and 5% in buffalo urine, of the total-N added through 50 and 100 ml urine samples. Carbon dioxide emissions were standardized at 25 degrees C by using a suitable formula which were lower than actual emissions at actual soil temperature (> 25 degrees C). Carbon dioxide emission rates were classified on the basis of soil repiratory classification and classes ranged from moderately low soil activity up to unusually high soil activity, the latter observed only on very few sampling days. Grasses in the microcosm had shown appreciable growth after urine application. Although variable and somewhat unpredictable, emissions were appreciable and that too only from a patch of single urination, indicating to the huge magnitude of total emissions under the scenario of thousands of cattle grazing on hundreds of acres of grasslands in a tropical country.

  6. Prevalence of isolated non-albumin proteinuria in the US population tested for both, urine total protein and urine albumin: An unexpected discovery.

    PubMed

    Katayev, Alexander; Zebelman, Arthur M; Sharp, Thomas M; Samantha Flynn; Bernstein, Richard K

    2017-04-01

    Isolated non-albumin proteinuria (NAP) is a condition when urine total protein concentrations are elevated without elevation of urine albumin. The prevalence of NAP in the US population tested for both, urine total protein and albumin was assessed in this study. The database of a US nationwide laboratory network was queried for test results when random urine albumin was ordered together with urine total protein and also when timed 24-hour urine albumin was ordered together with urine total protein. The total prevalence of NAP in the US population tested for both, urine total protein and albumin was calculated for patient groups having normal and low-normal urine albumin (random and timed) with elevated and severely increased urine total protein (random and timed). Also, the prevalence of NAP was calculated for patients with normal urine albumin to assess the probability of missing proteinuria if only urine albumin is measured. The prevalence of NAP in the random samples group was 10.1% (15.2% for females and 4.7% for males). Among patients with normal random albumin, there were 20.0% (27.3% of females and 10.7% of males) patients with NAP. The prevalence of NAP in the timed samples group was 24.6% (29.8% for females and 18.5% for males). Among patients with normal timed urine albumin, there were 36.2% (40.0% of females and 30.8% of males) patients with NAP. There was a strong positive association with female gender and NAP in most patients groups. Testing for only urine (micro)albumin can miss up to 40% of females and 30.8% of males with gross proteinuria. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Characterization of ultrafiltration of undiluted and diluted stored urine.

    PubMed

    Ouma, J; Septien, S; Velkushanova, K; Pocock, J; Buckley, C

    2016-11-01

    Urine ultrafiltration (UF) was studied in terms of flux, permeability, resistance and fouling. Two types of samples were used: stored urine representing the feedstock obtained from urine diversion dry toilets; and diluted stored urine representing the feedstock obtained from urinals. Three different filtration experiment sets were adopted in this study. For the first case, pressure was set in an ascending order, i.e. from 10 to 60 kPa during filtration of stored urine. For the second case, pressure was set in a descending order, i.e. from 60 to 10 kPa for the same feed stream. The third case involved filtration of diluted urine with pressure in ascending order, i.e. from 10 to 60 kPa. The results indicated that diluted urine had higher flux than undiluted urine with maximum values of 43 and 26 L·m -2 ·h -1 respectively. Cake formation was the dominating fouling mechanism during urine filtration with a contribution of about 90% to the total hydraulic resistance. The contribution of chemically irreversible fouling was low (-2%), unless operating from high to low pressures. Indeed, irreversible fouling appeared to be greater during the experiments starting at higher pressure. Although undiluted urine had a higher fouling potential compared to diluted urine, the specific cake resistance was higher for diluted urine, probably due to a denser cake caused by lower particle sizes in that sample. The permeate obtained after urine filtration had much lower suspended solids content compared to the feedstock, with rejections up to 99%. The concentration of the ionic species remained unchanged, and 75% of the organic compounds and dissolved solids remained in the permeate. Urine UF could then be used as pre-treatment to remove suspended solids.

  8. Airborne particulate metals in the New York City subway: A pilot study to assess the potential for health impacts✩,✩✩

    PubMed Central

    Grass, David S.; Ross, James M.; Family, Farnosh; Barbour, Jonathan; Simpson, H. James; Coulibaly, Drissa; Hernandez, Jennifer; Chen, Yingdi; Slavkovich, Vesna; Li, Yongliang; Graziano, Joseph; Santella, Regina M.; Brandt-Rauf, Paul; Chillrud, Steven N.

    2011-01-01

    A prior study in New York City observed that airborne concentrations of three metals found in steel – iron, manganese, and chromium – are more than 100 times higher in the subway system than in aboveground air. To investigate the potential for health effects of exposure at these levels, we conducted a pilot study of subway workers comparing personal exposures to steel dust with biomarkers of metal exposure, oxidative stress, and DNA damage in blood and urine samples. Workers wore a personal air sampler operating at 4 L/m for one to three work shifts with blood and urine samples collected at the end of the final shift. We found that PM2.5 exposures varied among subway workers on the basis of job title and job activity. The subway workers’ mean time-weighted PM2.5 exposure was 52 µg/m3, with a median of 27 µg/m3, and a range of 6–469 µg/m3. The observed concentrations of PM2.5, iron, manganese, and chromium fell well below occupational standards. Biomarker concentrations among the 39 subway workers were compared with a group of 11 bus drivers, and a group of 25 suburban office workers. Concentrations of DNA–protein crosslinks and chromium in plasma were significantly higher in subway workers than in bus drivers, but no significant difference was observed for these biomarkers between subway workers and office workers. Urinary isoprostane concentrations were significantly correlated with the number of years working in the subway system, and were detected at higher, though not significantly higher, concentrations in subway workers than in bus drivers or office workers. At the group level, there was no consistent pattern of biomarker concentrations among subway workers significantly exceeding those of the bus drivers and office workers. At the individual level, steel dust exposure was not correlated with any of the biomarkers measured. PMID:19926083

  9. Airborne particulate metals in the New York City subway: a pilot study to assess the potential for health impacts.

    PubMed

    Grass, David S; Ross, James M; Family, Farnosh; Barbour, Jonathan; James Simpson, H; Coulibaly, Drissa; Hernandez, Jennifer; Chen, Yingdi; Slavkovich, Vesna; Li, Yongliang; Graziano, Joseph; Santella, Regina M; Brandt-Rauf, Paul; Chillrud, Steven N

    2010-01-01

    A prior study in New York City observed that airborne concentrations of three metals found in steel - iron, manganese, and chromium - are more than 100 times higher in the subway system than in aboveground air. To investigate the potential for health effects of exposure at these levels, we conducted a pilot study of subway workers comparing personal exposures to steel dust with biomarkers of metal exposure, oxidative stress, and DNA damage in blood and urine samples. Workers wore a personal air sampler operating at 4L/m for one to three work shifts with blood and urine samples collected at the end of the final shift. We found that PM(2.5) exposures varied among subway workers on the basis of job title and job activity. The subway workers' mean time-weighted PM(2.5) exposure was 52 microg/m3, with a median of 27 microg/m3, and a range of 6-469 microg/m3. The observed concentrations of PM(2.5), iron, manganese, and chromium fell well below occupational standards. Biomarker concentrations among the 39 subway workers were compared with a group of 11 bus drivers, and a group of 25 suburban office workers. Concentrations of DNA-protein crosslinks and chromium in plasma were significantly higher in subway workers than in bus drivers, but no significant difference was observed for these biomarkers between subway workers and office workers. Urinary isoprostane concentrations were significantly correlated with the number of years working in the subway system, and were detected at higher, though not significantly higher, concentrations in subway workers than in bus drivers or office workers. At the group level, there was no consistent pattern of biomarker concentrations among subway workers significantly exceeding those of the bus drivers and office workers. At the individual level, steel dust exposure was not correlated with any of the biomarkers measured.

  10. Nitrites in Urine

    MedlinePlus

    ... Why do I need a nitrites in urine test? Your health care provider may have ordered a urinalysis as part ... Fever What happens during a nitrites in urine test? Your health care provider will need to collect a sample of ...

  11. Urobilinogen in Urine

    MedlinePlus

    ... Why do I need a urobilinogen in urine test? Your health care provider may have ordered this test as part ... skin What happens during a urobilinogen in urine test? Your health care provider will need to collect a sample of ...

  12. Microbiological test results using three urine pretreatment regimes with 316L stainless steel

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

  13. Carbon-monoxide poisoning in young drug addicts due to indoor use of a gasoline-powered generator.

    PubMed

    Marc, B; Bouchez-Buvry, A; Wepierre, J L; Boniol, L; Vaquero, P; Garnier, M

    2001-06-01

    We report six fatal cases of unintentional carbon-monoxide poisoning which occurred in a house occupied by young people. The source of carbon monoxide was a gasoline-powered generator. For all victims, an external body examination was carried out and blood and urine samples collected. Blood carboxyhaemoglobin (COHb) was performed using an automated visible spectrophotometric analysis. Blood-alcohol level quantification was performed using gas chromatography and drug screening in urine was performed by a one-step manual qualitative immunochromatography (Syva Rapid test, Behring Diagnostics Inc.) for benzoylecgonine (the main metabolite of cocaine in urine), morphine, 11-nor-Delta(9)-THC-9-COOH (cannabinoids) and d-methamphetamine. In all victims the COHb value was as high or higher than 65%. No alcohol was found in blood samples, but urine samples were positive for methamphetamine, cocaine and cannabis in five cases and for opiates in one case. In four victims, the urine sample was positive for at least three drugs. The availability and accuracy of rapid toxicological screening is an important tool for the medical examiner at the immediate scene of a clinical forensic examination.

  14. Mutagens in urine of non-smoking and smoking workers in an aircraft tyre retreading plant. Skin exposure as a causal factor?

    PubMed

    Bos, R P; Kromhout, H; Ikink, H; de Haan, W; Koppejan, J; Theuws, J L

    1989-05-01

    In an aircraft type retreading plant environmental samples taken at several departments showed mutagenic properties. Thursday urine samples of non-smoking and smoking workers showed higher urinary mutagenicity than urine samples collected on Sundays, thus suggesting occupational exposure to mutagenic substances. A relation between urinary mutagenicity on Thursdays and skin contamination measured on Wednesdays was observed. The data suggest that intake through the skin plays an important role in the occupational exposure to mutagenic compounds of rubber workers.

  15. Short-term markers of DNA damage among roofers who work with hot asphalt.

    PubMed

    Serdar, Berrin; Brindley, Stephen; Dooley, Greg; Volckens, John; Juarez-Colunga, Elizabeth; Gan, Ryan

    2016-10-20

    Roofers are at increased risk for various malignancies and their occupational exposures to polycyclic aromatic hydrocarbons (PAHs) have been considered as important risk factors. The overall goal of this project was to investigate the usefulness of phosphorylated histone H2AX (γH2AX) as a short-term biomarker of DNA damage among roofers. Blood, urine, and dermal wipe samples were collected from 20 roofers who work with hot asphalt before and after 6 h of work on Monday and Thursday of the same week (4 sampling periods). Particle-bound and gas-phase PAHs were collected using personal monitors during work hours. γH2AX was quantified in peripheral lymphocytes using flow cytometry and 8-hydroxy-2-deoxyguanosine (8-OHdG) was assessed in urine using ELISA. General linear mixed models were used to evaluate associations between DNA damage and possible predictors (such as sampling period, exposure levels, work- and life-style factors). Differences in mean biomarker and DNA damage levels were tested via ANOVA contrasts. Exposure measurements did not show an association with any of the urinary biomarkers or the measures of DNA damage. Naphthalene was the most abundant PAH in gas-phase, while benzo(e)pyrene was the most abundant particle-bound PAH. Post-shift levels of γH2AX and 8-OHdG were higher on both study days, when compared to pre-shift levels. Cigarette smoking was a predictor of γH2AX and urinary creatinine was a predictor of urinary 8-OHdG. Between-subject variance to total variance ratio was 35.3 % for γH2ax and 4.8 % for 8-OHdG. γH2AX is a promising biomarker of DNA damage in occupational epidemiology studies. It has a lower within-subject variation than urinary 8-OHdG and can easily be detected in large scale groups. Future studies that explore the kinetics of H2AX phosphorylation in relation to chemical exposures may reveal the transient and persistent nature of this sensitive biomarker of early DNA damage.

  16. The void in using urine concentration to assess population fluid intake adequacy or hydration status.

    PubMed

    Cheuvront, Samuel N; Muñoz, Colleen X; Kenefick, Robert W

    2016-09-01

    Urine concentration can be used to assess fluid intake adequacy or to diagnose dehydration. However, too often urine concentration is used inappropriately to draw dubious conclusions that could have harmful health and economic consequences. Inappropriate uses of urine concentration relate primarily to convenience sampling (timing) and problems related to convenience sampling (misapplication of thresholds), but a conceptual problem also exists with using urine concentration in isolation. The purpose of this Perspective article is to briefly explain the problematic nature of current practices and to offer a possible solution to improve practice with minimal added complication. When urine is used exclusively to assess fluid intake adequacy and hydration status in adults, we propose that only when urine concentration is high (>850 mmol/kg) and urine excretion rate is low (<850 mL/24 h) should suspicion of inadequate drinking or impending dehydration be considered. Prospective tests of the 850 × 850 thresholds will provide supporting evidence and/or help refine the best thresholds for men and women, young and old. © 2016 American Society for Nutrition.

  17. Objective non-intrusive markers of sperm production and sexual activity

    PubMed Central

    Sivananthan, Thilee; Bathur, Franz; Jimenez, Mark; Conway, Ann; Idan, Amanda; Handelsman, David

    2012-01-01

    Objective studies of men's reproductive function are hindered by their reliance on: (i) self-reporting to quantify sexual activity and (ii) masturbation to quantify sperm output rendering both types of estimate vulnerable to unverifiable subjective factors. We therefore examined whether detection of spermatozoa and measurement of prostate-specific antigen (PSA) in urine could provide objective semiquantitative estimates of sperm output and recent ejaculation, respectively, using widely available laboratory techniques. Of 11 healthy volunteers who provided urine samples before and at intervals for 5 days after ejaculation, sperm was present in 2/11 men before, and in all 11/11 samples immediately after ejaculation, but by the second and subsequent void, spermatozoa were present in ∼10%. PSA was detectable at high levels in all urine samples, peaking at the first post-ejaculatory sample but returning to baseline levels by the second post-ejaculatory void. We conclude that urinary spermatozoa and PSA are objective biomarkers for sperm production and sexual activity, but only for a short-time window until the first post-ejaculatory urine void. Hence, for a single urine specimen, the presence of spermatozoa and PSA are valid biomarkers, reflecting sperm production and recent ejaculation only until the next micturition, so their measurement should be restricted to the first morning urine void. PMID:22522506

  18. The use of laser-induced fluorescence or ultraviolet detectors for sensitive and selective analysis of tobramycin or erythropoietin in complex samples.

    PubMed

    Ahmed, Hytham M; Ebeid, Wael B

    2015-05-15

    Complex samples analysis is a challenge in pharmaceutical and biopharmaceutical analysis. In this work, tobramycin (TOB) analysis in human urine samples and recombinant human erythropoietin (rhEPO) analysis in the presence of similar protein were selected as representative examples of such samples analysis. Assays of TOB in urine samples are difficult because of poor detectability. Therefore laser induced fluorescence detector (LIF) was combined with a separation technique, micellar electrokinetic chromatography (MEKC), to determine TOB through derivatization with fluorescein isothiocyanate (FITC). Borate was used as background electrolyte (BGE) with negative-charged mixed micelles as additive. The method was successively applied to urine samples. The LOD and LOQ for Tobramycin in urine were 90 and 200ng/ml respectively and recovery was >98% (n=5). All urine samples were analyzed by direct injection without sample pre-treatment. Another use of hyphenated analytical technique, capillary zone electrophoresis (CZE) connected to ultraviolet (UV) detector was also used for sensitive analysis of rhEPO at low levels (2000IU) in the presence of large amount of human serum albumin (HSA). Analysis of rhEPO was achieved by the use of the electrokinetic injection (EI) with discontinuous buffers. Phosphate buffer was used as BGE with metal ions as additive. The proposed method can be used for the estimation of large number of quality control rhEPO samples in a short period. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Polymerase Chain Reaction Detection of Leishmania kDNA from the Urine of Peruvian Patients with Cutaneous and Mucocutaneous Leishmaniasis

    PubMed Central

    Veland, Nicolas; Espinosa, Diego; Valencia, Braulio Mark; Ramos, Ana Pilar; Calderon, Flor; Arevalo, Jorge; Low, Donald E.; Llanos-Cuentas, Alejandro; Boggild, Andrea K.

    2011-01-01

    We hypothesized that Leishmania kDNA may be present in urine of patients with cutaneous leishmaniasis (CL). Urine samples and standard diagnostic specimens were collected from patients with skin lesions. kDNA polymerase chain reaction (PCR) was performed on samples from patients and 10 healthy volunteers from non-endemic areas. Eighty-six of 108 patients were diagnosed with CL and 18 (21%) had detectable Leishmania Viannia kDNA in the urine. Sensitivity and specificity were 20.9% (95% confidence interval [CI] 12.3–29.5%) and 100%. Six of 8 patients with mucocutaneous involvement had detectable kDNA in urine versus 12 of 78 patients with isolated cutaneous disease (P < 0.001). L. (V.) braziliensis (N = 3), L. (V.) guyanensis (N = 6), and L. (V.) peruviana (N = 3) were identified from urine. No healthy volunteer or patient with an alternate diagnosis had detectable kDNA in urine. Sensitivity of urine PCR is sub-optimal for diagnosis. On the basis of these preliminary data in a small number of patients, detectable kDNA in urine may identify less localized forms of infection and inform treatment decisions. PMID:21460009

  20. Stamping SERS for creatinine sensing

    NASA Astrophysics Data System (ADS)

    Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Santos, Greggy M.; Mohan, Chandra; Shih, Wei-Chuan

    2015-03-01

    Urine can be obtained easily, readily and non-invasively. The analysis of urine can provide metabolic information of the body and the condition of renal function. Creatinine is one of the major components of human urine associated with muscle metabolism. Since the content of creatinine excreted into urine is relatively constant, it is used as an internal standard to normalize water variations. Moreover, the detection of creatinine concentration in urine is important for the renal clearance test, which can monitor the filtration function of kidney and health status. In more details, kidney failure can be imminent when the creatinine concentration in urine is high. A simple device and protocol for creatinine sensing in urine samples can be valuable for point-of-care applications. We reported quantitative analysis of creatinine in urine samples by using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) based SERS substrate. S-SERS technique enables label-free and multiplexed molecular sensing under dry condition, while NPGD provides a robust, controllable, and high-sensitivity SERS substrate. The performance of S-SERS with NGPDs is evaluated by the detection and quantification of pure creatinine and creatinine in artificial urine within physiologically relevant concentration ranges.

  1. Pure human urine is a good fertiliser for cucumbers.

    PubMed

    Heinonen-Tanski, Helvi; Sjöblom, Annalena; Fabritius, Helena; Karinen, Päivi

    2007-01-01

    Human urine obtained from separating toilets was tested as a fertiliser for cultivation of outdoor cucumber (Cucumis sativus L.) in a Nordic climate. The urine used contained high amounts of nitrogen with some phosphorus and potassium, but numbers of enteric microorganisms were low even though urine had not been preserved before sampling. The cucumber yield after urine fertilisation was similar or slightly better than the yield obtained from control rows fertilised with commercial mineral fertiliser. None of the cucumbers contained any enteric microorganisms (coliforms, enterococci, coliphages and clostridia). In the taste assessment, 11 out of 20 persons could recognise which cucumber of three cucumbers was different but they did not prefer one over the other cucumber samples, since all of them were assessed as equally good.

  2. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, C.; Dietz, M.; Kaminski, M.

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial,more » extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.« less

  3. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains the analytical results for measurements of up to 8 pesticide metabolites in 86 samples over 86 households. Each sample was collected form the primary respondent within each household. The sample consists of the first morning ...

  4. Risk factors for human papillomavirus detection in urine samples of heterosexual men visiting urological clinics in Japan.

    PubMed

    Nakashima, Kazufumi; Shigehara, Kazuyoshi; Kitamura, Tadaichi; Yaegashi, Hiroshi; Shimamura, Masayoshi; Kawaguchi, Shohei; Izumi, Kouji; Kadono, Yoshifumi; Mizokami, Atsushi

    2018-05-11

    The present study aimed to investigate human papillomavirus (HPV) prevalence and identify risk factors for HPV detection in urine samples among heterosexual men attending urological clinics. Spot urine samples including initial stream were collected from 845 participants, and the cell pellets were preserved into liquid-based cytological solution. After DNA extraction from each sample, HPV-DNA amplification and genotyping were performed using Luminex multiplex polymerase chain reaction. Participants completed a questionnaire on their age, education, smoking status, sexuality, age of sexual debut, marital status, and present history of sexually transmitted infections. Data from 803 patients were included in the analysis. Overall HPV and high-risk (HR)HPV prevalence in urine samples were 6.2% and 3.1%, respectively. HPV and HR-HPV prevalences were the highest in men with urethritis, and were significantly higher than those without urethritis. HPV detection was the most common in men aged 40-49 years, although significant detection differences were not age-related. Urethritis was an independent risk factor for HPV detection from urine samples, with an odds ratio (OR) of 4.548 (95%CI; 1.802-11.476) (p = 0.001). On the other hand, a sub-analysis excluding men with urethritis demonstrated that prostate cancer was a significant risk factor for HPV detection, with OR of 2.844 (95%CI; 1.046-7.732) (p = 0.0410), whereas was not a significant risk for HR-HPV detection in urine samples. Prostate cancer may represent a risk factor for HPV detection in the urine of men without urethritis. The authors did not register to Clinical Trial because this is observational and cross-sectional study. Copyright © 2018 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  5. Prediction of space sickness in astronauts from preflight fluid, electrolyte, and cardiovascular variables and Weightless Environmental Training Facility (WETF) training

    NASA Technical Reports Server (NTRS)

    Simanonok, K.; Mosely, E.; Charles, J.

    1992-01-01

    Nine preflight variables related to fluid, electrolyte, and cardiovascular status from 64 first-time Shuttle crewmembers were differentially weighted by discrimination analysis to predict the incidence and severity of each crewmember's space sickness as rated by NASA flight surgeons. The nine variables are serum uric acid, red cell count, environmental temperature at the launch site, serum phosphate, urine osmolality, serum thyroxine, sitting systolic blood pressure, calculated blood volume, and serum chloride. Using two methods of cross-validation on the original samples (jackknife and a stratefied random subsample), these variables enable the prediction of space sickness incidence (NONE or SICK) with 80 percent sickness and space severity (NONE, MILD, MODERATE, of SEVERE) with 59 percent success by one method of cross-validation and 67 percent by another method. Addition of a tenth variable, hours spent in the Weightlessness Environment Training Facility (WETF) did not improve the prediction of space sickness incidences but did improve the prediction of space sickness severity to 66 percent success by the first method of cross-validation of original samples and to 71 percent by the second method. Results to date suggest the presence of predisposing physiologic factors to space sickness that implicate fluid shift etiology. The data also suggest that prior exposure to fluid shift during WETF training may produce some circulatory pre-adaption to fluid shifts in weightlessness that results in a reduction of space sickness severity.

  6. Detection of depleted uranium in urine of veterans from the 1991 Gulf War.

    PubMed

    Gwiazda, R H; Squibb, K; McDiarmid, M; Smith, D

    2004-01-01

    American soldiers involved in "friendly fire" accidents during the 1991 Gulf War were injured with depleted-uranium-containing fragments or possibly exposed to depleted uranium via other routes such as inhalation, ingestion, and/or wound contamination. To evaluate the presence of depleted uranium in these soldiers eight years later, the uranium concentration and depleted uranium content of urine samples were determined by inductively coupled plasma mass spectrometry in (a) depleted uranium exposed soldiers with embedded shrapnel, (b) depleted uranium exposed soldiers with no shrapnel, and (c) a reference group of deployed soldiers not involved in the friendly fire incidents. Uranium isotopic ratios measured in many urine samples injected directly into the inductively coupled plasma mass spectrometer and analyzed at a mass resolution m/delta m of 300 appeared enriched in 235U with respect to natural abundance (0.72%) due to the presence of an interference of a polyatomic molecule of mass 234.81 amu that was resolved at a mass resolution m/delta m of 4,000. The 235U abundance measured on uranium separated from these urines by anion exchange chromatography was clearly natural or depleted. Urine uranium concentrations of soldiers with shrapnel were higher than those of the two other groups, and 16 out of 17 soldiers with shrapnel had detectable depleted uranium in their urine. In depleted uranium exposed soldiers with no shrapnel, depleted uranium was detected in urine samples of 10 out of 28 soldiers. The median uranium concentration of urines with depleted uranium from soldiers without shrapnel was significantly higher than in urines with no depleted uranium, though substantial overlap in urine uranium concentrations existed between the two groups. Accordingly, assessment of depleted uranium exposure using urine must rely on uranium isotopic analyses, since urine uranium concentration is not an unequivocal indicator of depleted uranium presence in soldiers with no embedded shrapnel.

  7. Determination of the GABA analogue succinic semialdehyde in urine and cerebrospinal fluid by dinitrophenylhydrazine derivatization and liquid chromatography-tandem mass spectrometry: application to SSADH deficiency.

    PubMed

    Struys, E A; Jansen, E E W; Gibson, K M; Jakobs, C

    2005-01-01

    Succinic semialdehyde (SSA) accumulates in the inborn error of meta- bolism succinic semialdehyde dehydrogenase deficiency owing to impaired enzymatic conversion to succinic acid. We developed a stable-isotope dilution liquid chromato- graphy-tandem mass spectrometry method for the determination of SSA in urine and cerebrospinal fluid samples. Stable-isotope-labelled [13C4]SSA, serving as internal standard, was prepared by reaction of ninhydrin with L-[13C5]glutamic acid. SSA in body fluids was converted to its dinitrophenylhydrazine (DNPH) derivative, without sample purification prior to the derivatization procedure. The DNPH derivative of SSA was injected onto a C18 analytical column and chromatography was performed by isocratic elution. Detection was accomplished by tandem mass spectrometry operating in the negative multiple-reaction monitoring mode. The limit of detection was 10 nmol/L and the calibration curves over the range 0-500 pmol of SSA showed good linearity (r2 > 0.99). The intra-day coefficient of variation (n = 10) for urine was 2.7% and inter-day coefficient of variation (n = 5) for urine was 8.5%. The average recoveries performed on two levels by enriching urine and cerebrospinal fluid samples ranged between 85 and 115%, with coefficients of variation < 8%. The method enabled the first determination of normal values for SSA in urine and pathological values of SSA in urine and cerebrospinal fluid samples derived from patients with succinic semialdehyde dehydrogenase deficiency.

  8. Urine Sample Preparation in 96-Well Filter Plates for Quantitative Clinical Proteomics

    PubMed Central

    2015-01-01

    Urine is an important, noninvasively collected body fluid source for the diagnosis and prognosis of human diseases. Liquid chromatography mass spectrometry (LC-MS) based shotgun proteomics has evolved as a sensitive and informative technique to discover candidate disease biomarkers from urine specimens. Filter-aided sample preparation (FASP) generates peptide samples from protein mixtures of cell lysate or body fluid origin. Here, we describe a FASP method adapted to 96-well filter plates, named 96FASP. Soluble urine concentrates containing ∼10 μg of total protein were processed by 96FASP and LC-MS resulting in 700–900 protein identifications at a 1% false discovery rate (FDR). The experimental repeatability, as assessed by label-free quantification and Pearson correlation analysis for shared proteins among replicates, was high (R ≥ 0.97). Application to urinary pellet lysates which is of particular interest in the context of urinary tract infection analysis was also demonstrated. On average, 1700 proteins (±398) were identified in five experiments. In a pilot study using 96FASP for analysis of eight soluble urine samples, we demonstrated that protein profiles of technical replicates invariably clustered; the protein profiles for distinct urine donors were very different from each other. Robust, highly parallel methods to generate peptide mixtures from urine and other body fluids are critical to increase cost-effectiveness in clinical proteomics projects. This 96FASP method has potential to become a gold standard for high-throughput quantitative clinical proteomics. PMID:24797144

  9. Chemical Method of Urine Volume Measurement

    NASA Technical Reports Server (NTRS)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  10. Detection of recombinant EPO in blood and urine samples with EPO WGA MAIIA, IEF and SAR-PAGE after microdose injections.

    PubMed

    Dehnes, Yvette; Shalina, Alexandra; Myrvold, Linda

    2013-01-01

    The misuse of microdoses of performance enhancing drugs like erythropoietin (EPO) constitutes a major challenge in doping analysis. When injected intravenously, the half-life of recombinant human EPO (rhEPO) like epoetin alfa, beta, and zeta is only a few hours and hence, the window for direct detection of rhEPO in urine is small. In order to investigate the detection window for rhEPO directly in blood and urine with a combined affinity chromatography and lateral flow immunoassay (EPO WGA MAIIA), we recruited nine healthy people who each received six intravenously injected microdoses (7.5 IU/kg) of NeoRecormon (epoetin beta) over a period of three weeks. Blood and urine samples were collected in the days following the injections and analyzed with EPO WGA MAIIA as well as the current validated methods for rhEPO; isoelectric focusing (IEF) and sarcosyl polyacrylamide gel electrophoresis (SAR-PAGE). For samples collected 18 h after a microdose, the sensitivity of the EPO WGA MAIIA assay was 100% in plasma and 87.5% in urine samples at the respective 98% specificity threshold levels. In comparison, the sensitivity in plasma and urine was 75% and 100%, respectively, with IEF, and 87.5% in plasma and 100% in urine when analyzed with SAR-PAGE. We conclude that EPO WGA MAIIA is a sensitive assay for the detection of rhEPO, with the potential of being a fast, supplemental screening assay for use in doping analysis.

  11. Flow-injection chemiluminescence determination of melamine in urine and plasma.

    PubMed

    Tang, Xiaoshuang; Shi, Xiyan; Tang, Yuhai; Yue, Zhongjin; He, Qiqi

    2012-01-01

    A novel flow-injection chemiluminescence method for the determination of melamine in urine and plasma was developed. It was found that melamine can remarkably enhance chemiluminescence emission from the luminol-K(3) Fe(CN)(6) system in an alkaline medium. Under the optimum conditions, chemiluminescence intensity had a good linear relationship with the concentration of melamine in the range 9.0 × 10(-9) -7.0 × 10(-6) g/mL, with a correlation coefficient of 0.9992. The detection limit (3σ) was 3.5 ng/mL. The method has been applied to determine the concentration of melamine in samples using liquid-liquid extraction. Average recoveries of melamine were 102.6% in urine samples and 95.1% in plasma samples. The method provided a reproducible and stable approach for the sensitive detection of melamine in urine and plasma samples. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Detection of West Nile virus lineage 2 in the urine of acute human infections.

    PubMed

    Papa, Anna; Testa, Theodolinda; Papadopoulou, Elpida

    2014-12-01

    West Nile virus (WNV) lineage 2 emerged in Greece in 2010 and since then outbreaks in humans have been reported for four consecutive years. Laboratory diagnosis is based mainly on serology. A real-time RT-PCR was applied on urine samples obtained from 35 patients with acute WNV infection. WNV RNA was detected in 40% of the samples with cycle threshold (CT) values ranging from 26.95 to 39.89 (mean 33.11). WNV was isolated from two of four urine samples with low CT (<30). Viral load was not associated with patients' age, sex, day of illness, presence of WNV antibodies, and neurological symptoms. However, it seems that sample shipment and storage conditions are very important for virus detection and isolation. The usefulness of the WNV RNA detection in urine as a diagnostic tool of acute WNV infections is discussed. © 2014 Wiley Periodicals, Inc.

  13. SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.

    PubMed

    Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D

    2006-03-01

    Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.

  14. Rapid test by liquid chromatography/tandem mass spectrometry to evaluate equine urine reactivity towards 17beta-OH steroids.

    PubMed

    Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero

    2006-01-01

    Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.

  15. Strong-LAMP: A LAMP Assay for Strongyloides spp. Detection in Stool and Urine Samples. Towards the Diagnosis of Human Strongyloidiasis Starting from a Rodent Model

    PubMed Central

    Gandasegui, Javier; Bajo Santos, Cristina; López-Abán, Julio; Saugar, José María; Rodríguez, Esperanza; Vicente, Belén; Muro, Antonio

    2016-01-01

    Background Strongyloides stercoralis, the chief causative agent of human strongyloidiasis, is a nematode globally distributed but mainly endemic in tropical and subtropical regions. Chronic infection is often clinically asymptomatic but it can result in severe hyperinfection syndrome or disseminated strongyloidiasis in immunocompromised patients. There is a great diversity of techniques used in diagnosing the disease, but definitive diagnosis is accomplished by parasitological examination of stool samples for morphological identification of parasite. Until now, no molecular method has been tested in urine samples as an alternative to stool samples for diagnosing strongyloidiasis. This study aimed to evaluate the use of a new molecular LAMP assay in a well-established Wistar rat experimental infection model using both stool and, for the first time, urine samples. The LAMP assay was also clinically evaluated in patients´ stool samples. Methodology/Principal Findings Stool and urine samples were obtained daily during a 28-day period from rats infected subcutaneously with different infective third-stage larvae doses of S. venezuelensis. The dynamics of parasite infection was determined by daily counting the number of eggs per gram of feces from day 1 to 28 post-infection. A set of primers for LAMP assay based on a DNA partial sequence in the 18S rRNA gene from S. venezuelensis was designed. The set up LAMP assay (namely, Strong-LAMP) allowed the sensitive detection of S. venezuelensis DNA in both stool and urine samples obtained from each infection group of rats and was also effective in S. stercoralis DNA amplification in patients´ stool samples with previously confirmed strongyloidiasis by parasitological and real-time PCR tests. Conclusions/Significance Our Strong-LAMP assay is an useful molecular tool in research of a strongyloidiasis experimental infection model in both stool and urine samples. After further validation, the Strong-LAMP could also be potentially applied for effective diagnosis of strongyloidiasis in a clinical setting. PMID:27415764

  16. Strong-LAMP: A LAMP Assay for Strongyloides spp. Detection in Stool and Urine Samples. Towards the Diagnosis of Human Strongyloidiasis Starting from a Rodent Model.

    PubMed

    Fernández-Soto, Pedro; Sánchez-Hernández, Alicia; Gandasegui, Javier; Bajo Santos, Cristina; López-Abán, Julio; Saugar, José María; Rodríguez, Esperanza; Vicente, Belén; Muro, Antonio

    2016-07-01

    Strongyloides stercoralis, the chief causative agent of human strongyloidiasis, is a nematode globally distributed but mainly endemic in tropical and subtropical regions. Chronic infection is often clinically asymptomatic but it can result in severe hyperinfection syndrome or disseminated strongyloidiasis in immunocompromised patients. There is a great diversity of techniques used in diagnosing the disease, but definitive diagnosis is accomplished by parasitological examination of stool samples for morphological identification of parasite. Until now, no molecular method has been tested in urine samples as an alternative to stool samples for diagnosing strongyloidiasis. This study aimed to evaluate the use of a new molecular LAMP assay in a well-established Wistar rat experimental infection model using both stool and, for the first time, urine samples. The LAMP assay was also clinically evaluated in patients´ stool samples. Stool and urine samples were obtained daily during a 28-day period from rats infected subcutaneously with different infective third-stage larvae doses of S. venezuelensis. The dynamics of parasite infection was determined by daily counting the number of eggs per gram of feces from day 1 to 28 post-infection. A set of primers for LAMP assay based on a DNA partial sequence in the 18S rRNA gene from S. venezuelensis was designed. The set up LAMP assay (namely, Strong-LAMP) allowed the sensitive detection of S. venezuelensis DNA in both stool and urine samples obtained from each infection group of rats and was also effective in S. stercoralis DNA amplification in patients´ stool samples with previously confirmed strongyloidiasis by parasitological and real-time PCR tests. Our Strong-LAMP assay is an useful molecular tool in research of a strongyloidiasis experimental infection model in both stool and urine samples. After further validation, the Strong-LAMP could also be potentially applied for effective diagnosis of strongyloidiasis in a clinical setting.

  17. Evaluation of open versus closed urine collection systems and development of nosocomial bacteriuria in dogs.

    PubMed

    Sullivan, Lauren A; Campbell, Vicki L; Onuma, Serene C

    2010-07-15

    To determine whether use of a closed urine collection system would decrease the incidence of nosocomial bacteriuria in hospitalized dogs, compared with use of an open urine collection system (used, sterile IV bags). Randomized controlled trial. 51 hospitalized dogs requiring indwelling urinary catheterization for >or= 24 hours. Dogs were randomly assigned to an open or closed urine collection system group. A standardized protocol for catheter placement and maintenance was followed for all dogs. A baseline urine sample was collected via cystocentesis for aerobic bacterial culture, with additional urine samples obtained daily from the urine collection reservoir. 27 dogs were assigned to the open urine collection system group, and 24 were assigned to the closed urine collection system group. The incidence of nosocomial bacteriuria in dogs with open urine collection systems (3/27 [11.1%]) was not significantly different from incidence in dogs with closed urine collection systems (2/24 [8.3%]). Median duration of catheterization was 2 days for dogs in both groups; the range was 1 to 7 days for dogs in the open group and 1 to 5 days for dogs in the closed group. Results suggested that for dogs requiring short-term indwelling urinary catheterization, the type of urine collection system (open vs closed) was not associated with likelihood of developing nosocomial bacteriuria. Use of a strict protocol for urinary catheter placement and maintenance was likely key in the low incidence of nosocomial bacteriuria in the present study.

  18. A new method for quasi-reagent-free biomonitoring of mercury in human urine.

    PubMed

    Schlathauer, Maria; Reitsam, Verena; Schierl, Rudolf; Leopold, Kerstin

    2017-05-01

    A novel analytical method for sampling and extraction of mercury (Hg) from human urine is presented in this work. The method is based on selective accumulation and separation of Hg from fresh urine sample onto active nanogold-coated silica material by highly efficient solid-phase extraction. After thermal desorption of Hg from the extractant, detection is performed by atomic fluorescence spectrometry (AFS). The feasibility and validity of the optimized, quasi-reagent-free approach was confirmed by recovery experiments in spiked real urine (recovery rate 96.13 ± 5.34%) and by comparison of found Hg concentrations in real urine samples - originating from occupationally exposed persons - with values obtained from reference methods cold vapor - atomic absorption spectrometry (CVAAS) and cold vapor - atomic fluorescence spectrometry (CV-AFS). A very good agreement of the found values reveals the validity of the proposed approach. The limit of detection (LOD) was found to be as low as 0.004 μg Hg L -1 and a high reproducibility with a relative standard deviations ≤4.2% (n = 6) is given. Moreover, storage of the samples for up to one week at an ambient temperature of 30 °C reveals no analyte losses or contamination. In conclusion, the proposed method enables easy-to-handle on-site extraction of total Hg from human urine ensuring at the same time reagent-free sample stabilization, providing quick and safe sampling, which can be performed by untrained persons. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Evaluation of Dried Urine Spot Method to Screen Cotinine among Tobacco Dependents: An Exploratory Study.

    PubMed

    Jain, Raka; Quraishi, Rizwana; Verma, Arpita

    2017-01-01

    Assessment of cotinine, a metabolite of nicotine in body fluids, is an important approach for validating the self-report among tobacco users. Adaptation of assays on dried urine spots (DUSs) has advantages of ease of collection, transportation, minimal invasiveness, and requirement of small volume. The aim of the present study was to develop an efficient method for testing cotinine in DUSs and evaluating its clinical applicability. This involved optimization of conditions for detection, recovery, and stability of cotinine from dried urine, spotted on filter paper. Enzyme-linked immunosorbent assay was used for screening, whereas confirmation was done by gas chromatography. For clinical applicability, urine samples of tobacco users were tested. Water was found to be a suitable extracting solvent as compared to carbonate-bicarbonate buffer (pH 9.2) and saline. Screening was achieved by two punches taken from a 20 μl (diameter 1.3 cm) spotted urine samples, and confirmation was achieved by five complete circles each of 20 μl sample volume. The recovery was found to be 97% in water. Limit of detection for the method was found to be 100 ng/ml. No signs of significant degradation were found under all storage conditions. All the urine samples of tobacco users were found to be positive by a conventional method as well as DUSs, and the method proved to be efficient. DUS samples are a useful alternative for biological monitoring of recent nicotine use, especially in developing countries where sample logistics could be an important concern.

  20. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting

    PubMed Central

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    Introduction The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. Materials and methods 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Results Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Conclusions Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. PMID:27346967

  1. Prevalence of urinary tract infection in acutely unwell children in general practice: a prospective study with systematic urine sampling.

    PubMed

    O'Brien, Kathryn; Edwards, Adrian; Hood, Kerenza; Butler, Christopher C

    2013-02-01

    Urinary tract infection (UTI) in children may be associated with long-term complications that could be prevented by prompt treatment. To determine the prevalence of UTI in acutely ill children ≤ 5 years presenting in general practice and to explore patterns of presenting symptoms and urine sampling strategies. Prospective observational study with systematic urine sampling, in general practices in Wales, UK. In total, 1003 children were recruited from 13 general practices between March 2008 and July 2010. The prevalence of UTI was determined and multivariable analysis performed to determine the probability of UTI. Out of 597 (60.0%) children who provided urine samples within 2 days, the prevalence of UTI was 5.9% (95% confidence interval [CI] = 4.3% to 8.0%) overall, 7.3% in those < 3 years and 3.2% in 3-5 year olds. Neither a history of fever nor the absence of an alternative source of infection was associated with UTI (P = 0.64; P = 0.69, respectively). The probability of UTI in children aged ≥3 years without increased urinary frequency or dysuria was 2%. The probability of UTI was ≥5% in all other groups. Urine sampling based purely on GP suspicion would have missed 80% of UTIs, while a sampling strategy based on current guidelines would have missed 50%. Approximately 6% of acutely unwell children presenting to UK general practice met the criteria for a laboratory diagnosis of UTI. This higher than previously recognised prior probability of UTI warrants raised awareness of the condition and suggests clinicians should lower their threshold for urine sampling in young children. The absence of fever or presence of an alternative source of infection, as emphasised in current guidelines, may not rule out UTI in young children with adequate certainty.

  2. Measurement of Phenolic Environmental Estrogens in Women with Uterine Leiomyoma

    PubMed Central

    Shen, Yang; Xu, Qian; Ren, Mulan; Feng, Xu; Cai, Yunlang; Gao, Yongxing

    2013-01-01

    Objectives To investigate the effect of phenolic environmental estrogens on uterine leiomyoma from the perspective of clinical epidemiology. Methods Urine and blood samples were collected from Han women with uterine leiomyoma and women without uterine leiomyoma, living in Nanjing, China, between September 2011 and February 2013. A total of 156 urine samples and 214 blood samples were collected from the uterine leiomyoma group and 106 urine samples and 126 blood plasma samples from the control group. Bisphenol A (BPA), nonylphenol (NP) and octylphenol (OP) concentrations were determined by solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Results Phenolic environmental estrogens in the uterine leiomyoma and control groups were compared based on: gravida>3 and gravida ≤ 3. In participants with gravida>3, urine OP concentration was significantly (P<0.05) higher in the uterine leiomyoma group than in the control group. In participants with gravida ≤ 3, urine NP concentration was significantly (P<0.05) higher in the uterine leiomyoma group compared to controls. Despite obstetric history, urine BPA mean exposure concentration was significantly (P<0.05) different between uterine leiomyoma group and control group. The urine BPA concentration was not significantly (P>0.05) different between gravida>3 and gravida ≤ 3 patients. There was no significant (P>0.05) difference in plasma concentrations of BPA, OP and NP between the leiomyoma group and control group. Mean exposure concentration and range of distribution of BPA, OP and NP plasma concentration differed between the uterine leiomyoma and control group. Conclusion Exposure level of phenolic environmental estrogens in human was related with leiomyoma tumorigenesis. PMID:24255718

  3. Clinicians' interpretations of point of care urine culture versus laboratory culture results: analysis from the four-country POETIC trial of diagnosis of uncomplicated urinary tract infection in primary care.

    PubMed

    Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C

    2017-08-01

    Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Comparison of urine specific gravity values from total-solids refractometry and reagent strip method.

    PubMed

    Chatasingh, S; Tapaneya-Olarn, W

    1989-01-01

    The comparison of specific gravity values of 561 urine samples from TS meter and reagent strip was made. The data were divided into two groups: group 1-less than 2+ protein contained urine samples and group 2--equal or more than 2+ protein contained urine samples. The results revealed that the specific gravity values from both methods in both groups were statistically different (p less than 0.01) but they were correlated at r = 0.84 (p less than 0.001) and r = 0.73 (p less than 0.001) in group 1 and group 2, respectively. It was concluded that the reagent strip is suitable for use as a screening test but it should not be considered when precise measurement is necessary.

  5. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

    PubMed

    Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas

    2007-01-01

    Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.

  6. Potential semiochemicals in urine from free ranging wolverines (Gulo gulo Pallas, 1780)

    Treesearch

    William F. Wood; Jeffrey P. Copeland; Richard E. Yates; Iman K. Horsey; Lynne R. McGreevy

    2009-01-01

    Urine deposition has been observed as an important scent-marking behaviour among wolverines (Gulo gulo, Mustelinae, Mustelidae). Solid phase microextraction (SPME) of headspace volatiles of the urine from free ranging wolverines were examined by gas chromatography-mass spectrometry (GC-MS). Urine samples were collected directly from the bladder of live-trapped animals...

  7. Early Detection of Pressure Ulcer Development Following Traumatic Spinal Cord Injury Using Inflammatory Mediators.

    PubMed

    Krishnan, Shilpa; Karg, Patricia E; Boninger, Michael L; Vodovotz, Yoram; Constantine, Greg; Sowa, Gwendolyn A; Brienza, David M

    2016-10-01

    To identify changes in concentrations of inflammatory mediators in plasma and urine after traumatic spinal cord injury (SCI) and before the occurrence of a first pressure ulcer. Retrospective; secondary analysis of existing data. Acute hospitalization and inpatient rehabilitation sites at a university medical center. Individuals with a pressure ulcer and plasma samples (n=17) and individuals with a pressure ulcer and urine samples (n=15) were matched by age and plasma/urine sample days to individuals with SCI and no pressure ulcer (N=35). Not applicable. Plasma and urine samples were assayed in patients with SCI, capturing samples within 4 days after the SCI to a week before the formation of the first pressure ulcer. The Wilcoxon signed-rank test was performed to identify changes in the inflammatory mediators between the 2 time points. An increase in concentration of the chemokine interferon-γ-induced protein of 10kd/CXCL10 in plasma (P<.01) and a decrease in concentration of the cytokine interferon-α in urine (P=.01) were observed before occurrence of a first pressure ulcer (∼4d) compared with matched controls. Altered levels of inflammatory mediators in plasma and urine may be associated with pressure ulcer development after traumatic SCI. These inflammatory mediators should be explored as possible biomarkers for identifying individuals at risk for pressure ulcer formation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Secondhand smoke exposure within semi-open air cafes and tobacco specific 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) concentrations among nonsmoking employees.

    PubMed

    Vardavas, Constantine I; Karabela, Maria; Agaku, Israel T; Matsunaga, Yuko; Myridakis, Antonis; Kouvarakis, Antonis; Stephanou, Euripides G; Lymperi, Maria; Behrakis, Panagiotis K

    2014-10-01

    Secondhand smoke (SHS) is a defined occupational hazard. The association though between SHS exposure in semi-open air venues and tobacco specific carcinogen uptake is an area of debate. A cross sectional survey of 49 semi-open air cafes in Athens, Greece was performed during the summer of 2008, prior to the adoption of the national smoke free legislation. All venues had at least 1 entire wall open to allow for free air exchange. Indoor concentrations of particulate matter smaller than 2.5 microns (PM2.5) attributable to SHS were assessed during a work shift, while 1 non-smoking employee responsible for indoor and outdoor table service from each venue provided a post work shift urine sample for analysis of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL). Post work shift NNAL concentrations were correlated with work shift PM2.5 concentrations attributable to SHS (r = 0.376, p = 0.0076). Urinary NNAL concentrations among employees increased by 9.5%, per 10 μg/m(3) increase in PM2.5 concentrations attributable to SHS after controlling for the time of day and day of week. These results indicate that the commonly proposed practice of maintaining open sliding walls as a means of free air exchange does not lead to the elimination of employee exposure to tobacco specific carcinogens attributable to workplace SHS.

  9. Dermal exposure and urinary 1-hydroxypyrene among asphalt roofing workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClean, M.D.; Rinehart, R.D.; Sapkota, A.

    2007-07-01

    The primary objective of this study was to identify significant determinants of dermal exposure to polycyclic aromatic compounds (PACs) among asphalt roofing workers and use urinary 1-hydroxyprene (1-OHP) measurements to evaluate the effect of dermal exposure on total absorbed dose. The study population included 26 asphalt roofing workers who performed three primary tasks: tearing off old roofs, putting down new roofs, and operating the kettle at ground level. During multiple consecutive work shifts, dermal patch samples were collected from the underside of each worker's wrists and were analyzed for PACs, pyrene, and benzo(a)pyrene (BAP). During the same work week, urinemore » samples were collected at pre-shift, post-shift, and bedtime each day and were analyzed for 1-OHP (205 urine samples). Linear mixed effects models were used to evaluate the dermal measurements for the purpose of identifying important determinants of exposure, and to evaluate urinary 1-OHP measurements for the purpose of identifying important determinants of total absorbed dose. Dermal exposures to PAC, pyrene, and BAP were found to vary significantly by roofing task and by the presence of an old coal tar pitch roof. For each of the three analytes, the adjusted mean dermal exposures associated with tear-off were approximately four times higher than exposures associated with operating the kettle. Exposure to coal tar pitch was associated with a 6-fold increase in PAC exposure, an 8-fold increase in pyrene exposure and a 35-fold increase in BAP exposure. The presence of coal tar pitch was the primary determinant of dermal exposure, particularly for exposure to BAP. However, the task-based differences that were observed while controlling for pitch suggest that exposure to asphalt also contributes to dermal exposures.« less

  10. Understanding arsenic metabolism through a comparative study of arsenic levels in the urine, hair and fingernails of healthy volunteers from three unexposed ethnic groups in the United Kingdom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brima, Eid I.; Haris, Parvez I.; Jenkins, Richard O.

    2006-10-01

    Very little is known about arsenic (As) metabolism in healthy populations that are not exposed to high concentrations of As in their food or water. Here we present a study with healthy volunteers from three different ethnic groups, residing in Leicester, UK, which reveals statistically significant differences in the levels of total As in urine and fingernail samples. Urine (n = 63), hair (n = 36) and fingernail (n = 36) samples from Asians, Somali Black-Africans and Whites were analysed using inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectroscopy (GF-AAS). The results clearly show that themore » total concentrations of As in urine and fingernail samples of a Somali Black-African population (urine 7.2 {mu}g/g creatinine; fingernails 723.1 {mu}g/kg) are significantly (P < 0.05) different from the Asian (urine 24.5 {mu}g/g creatinine; fingernails 153.9 {mu}g/kg) and White groups (urine 20.9 {mu}g/g creatinine; fingernails 177.0 {mu}g/kg). The chemical speciation of As in the urine of the three groups was also measured using high performance liquid chromatography coupled to ICP-MS. This showed that the proportion of the total urinary As present as dimethylarsenate (DMA) was higher for the Somali Black-African group (50%) compared to the Asians (16%) and Whites (22%). However, there was no significant difference (P > 0.05) in the level of As in the hair samples from these three groups; Somali Black-Africans (116.0 {mu}g/kg), Asians (117.4 {mu}g/kg) and Whites (141.2 {mu}g/kg). Significantly different levels of total As in fingernail and urine and a higher percentage of urinary DMA in the Somali Black-Africans are suggestive of a different pattern of As metabolism in this ethnic group.« less

  11. Determination of modafinil in plasma and urine by reversed phase high-performance liquid-chromatography.

    PubMed

    Schwertner, Harvey A; Kong, Suk Bin

    2005-03-09

    Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.

  12. Multiwalled carbon nanotubes as a sorbent material for the solid phase extraction of lead from urine and subsequent determination by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero

    2014-11-01

    The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption-elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L- 1, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64-22.9 μg Pb L- 1).

  13. Determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine with mass selective detection.

    PubMed

    Hughes, D L; Ritter, D J; Wilson, R D

    2001-11-01

    Method development and validation studies have been completed on an assay that will allow the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. The accurate determination of 2,4-D in urine is an important factor in monitoring worker and population exposure. These studies successfully validated a method for the detection of 2,4-D in urine at a limit of quantitation (LOQ) of 5.00 ppb (parts per billion) using gas chromatography with mass selective detection (GC/MSD). The first study involved the determination of 2,4-D in control human urine and urine samples fortified with 2,4-D. Due to chromatographic interference, a second study was conducted using 14C-2,4-D to verify the recoverability of 2,4-D from human urine at low levels using the GC/MSD method. The second study supports the results of the original data. The 2,4-D was extracted from human urine using a procedure involving hydrolysis using potassium hydroxide, followed by a liquid-liquid extraction into methylene chloride. The extracted samples were derivatized with diazomethane. The methylated fraction was analyzed by GC/MSD. Quantitation was made by comparison to methylated reference standards of 2,4-D. Aliquots fortified at 5-, 50-, and 500-ppb levels were analyzed. The overall mean recovery for all fortified samples was 90.3% with a relative standard deviation of 14.31%.

  14. The International Space Station Urine Monitoring System (UMS)

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.

    2009-01-01

    A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.

  15. Determination of thiopental in urine sample with high-performance liquid chromatography using iodine-azide reaction as a postcolumn detection system.

    PubMed

    Zakrzewski, Robert; Ciesielski, Witold

    2005-09-25

    The reaction between iodine and azide ions induced by thiopental was utilized as a postcolumn reaction for chromatographic determination of thiopental. The method is based on the separation of thiopental on an Nova-Pak CN HP column with an acetonitrile-aqueous solution of sodium azide as a mobile phase, followed by spectrophotometric measurement of the residual iodine (lambda=350 nm) from the postcolumn iodine-azide reaction induced by thiopental after mixing an iodine solution containing iodide ions with the column effluent containing azide ions and thiopental. Chromatograms obtained for thiopental showed negative peaks as a result of the decrease in background absorbance. The detection limit (defined as S/N=3) was 20 nM (0.4 pmol injected amount) for thiopental. Calibration graphs, plotted as peak area versus concentrations, were linear from 40 nM. The elaborated method was applied to determine thiopental in urine samples. The detection limit (defined as S/N=3) was 0.025 nmol/ml urine. Calibration graphs, plotted as peak area versus concentrations, were linear from 0.05 nmol/ml urine. Authentic urine samples were analyzed, thiopental was determined at nmol/ml urine level.

  16. Preliminary study on application of urine amino acids profiling for monitoring of renal tubular injury using GLC-MS.

    PubMed

    Kazubek-Zemke, Maja; Rybka, Jacek; Marchewka, Zofia; Rybka, Wojciech; Pawlik, Krzysztof; Długosz, Anna

    2014-11-14

    The early diagnosis of the nephrotoxic effect of xenobiotics and drugs is still an unsolved problem. Recent studies suggest a correlation between the nephrotoxic activity of xenobiotics and increased concentration of amino acids in urine. The presented study was focused on the application of GLC-MS method for amino acids profiling in human urine as a noninvasive method for monitoring of kidney condition and tubular injury level. The analytic method is based on the conversion of the amino acids present in the sample to tert-butyldimethylsilyl (TBDMS) derivatives and their analysis by gas-liquid chromatography-mass spectrometry (GLC-MS). The procedure of urine sample preparation for chromatographic analysis was optimized. The presence of 12 amino acids in most of the tested healthy human urine samples was detected. The significant differences in the levels of particular amino acids between patients with tubular injury and healthy controls were found, especially for lysine, valine, serine, alanine and leucine (on average 30.0, 7.5, 3.6, 2.9 and 0.5 fold respectively). We found that this approach based on GLC-MS detection can be used in nephrotoxicity studies for urine amino acids monitoring in exposure to xenobiotics and drugs.

  17. Detection and quantification of rituximab in the human urine.

    PubMed

    Jacobs, Roland; Langer-Jacobus, Thais; Duong, Michelle; Stahl, Klaus; Haller, Hermann; Schmidt, Reinhold E; Schiffer, Mario

    2017-12-01

    B cell depletion by rituximab treatment might be inefficient in patients suffering from nephrotic syndrome. Due to the impaired glomerular filtration barrier a significant portion of the therapeutic antibody might be lost into the urinary space. In order to determine the amount of rituximab in the urine of such patients, CD20+ Daudi cells were stained with the patients' urine followed by a fluorochrome-labeled secondary antibody. Mean fluorescence intensity of that way labeled Daudi cells was determined by flow cytometry. Control samples with defined rituximab concentrations were used to create standard curves. The analyses revealed that all nephelometric IgG+ urine samples tested also manifested rituximab at concentrations between 100 and 46,707μg/L. The flow cytometry-based approach is an easy and reliable method to assess rituximab in patients' urine samples for monitoring individual rituximab treatment courses in all patients co-presenting impaired renal filtration. Presence of such antibodies in the urine could be considered as criteria to modify the formulation or modality of rituximab delivery in order to prevent the loss of the therapeutic antibodies and thereby ensuring efficacy of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Diagnostic performance of random urine samples using albumin concentration vs ratio of albumin to creatinine for microalbuminuria screening in patients with diabetes mellitus: a systematic review and meta-analysis.

    PubMed

    Wu, Hon-Yen; Peng, Yu-Sen; Chiang, Chih-Kang; Huang, Jenq-Wen; Hung, Kuan-Yu; Wu, Kwan-Dun; Tu, Yu-Kang; Chien, Kuo-Liong

    2014-07-01

    A random urine sample measuring the albumin concentration (UAC) without simultaneously measuring the urinary creatinine is less expensive than measuring the ratio of albumin to creatinine (ACR), but comparisons of their diagnostic performance for microalbuminuria screening among patients with diabetes mellitus (DM) have not been undertaken in previous meta-analyses. To compare the diagnostic performance of the UAC vs the ACR in random urine samples for microalbuminuria screening among patients with DM. Electronic literature searches of PubMed, MEDLINE, and Scopus for English-language publications from the earliest available date of indexing through July 31, 2012. Clinical studies assessing the UAC or the ACR of random urine samples in detecting the presence of microalbuminuria among patients with DM using a urinary albumin excretion rate of 30 to 300 mg/d in 24-hour timed urine collections as the criterion standard. Bivariate random-effects models for analysis and pooling of the diagnostic performance measures across studies, as well as comparisons between different screening tests. The primary end point was the diagnostic performance measures of the UAC or the ACR in random urine samples, as well as comparisons between them. We identified 14 studies, with a total of 2078 patients; 9 studies reported on the UAC, and 12 studies reported on the ACR. Meta-analysis showed pooled sensitivities of 0.85 and 0.87 for the UAC and the ACR, respectively, and pooled specificities of 0.88 and 0.88, respectively. No differences in sensitivity (P = .70), specificity (P = .63), or diagnostic odds ratios (P = .59) between the UAC and the ACR were found. The time point of urine collection did not affect the diagnostic performance of either test. The UAC and the ACR yielded high sensitivity and specificity for the detection of microalbuminuria. Because the diagnostic performance of the UAC is comparable to that of the ACR, our findings indicate that the UAC of random urine samples may become the screening tool of choice for the population with DM, considering the rising incidence of DM and the constrained health care resources in many countries.

  19. Evaluation of factors that affect analytic variability of urine protein-to-creatinine ratio determination in dogs.

    PubMed

    Rossi, Gabriele; Giori, Luca; Campagnola, Simona; Zatelli, Andrea; Zini, Eric; Paltrinieri, Saverio

    2012-06-01

    To determine whether preanalytic and analytic factors affect evaluation of the urinary protein-to-creatinine (UPC) ratio in dogs. 50 canine urine samples. The UPC ratio was measured to assess the intra-assay imprecision (20 measurements within a single session), the influence of predilution (1:10, 1:20, and 1:100) for urine creatinine concentration measurement, and the effect of storage at room temperature (approx 20°C), 4°C, and -20°C. The coefficient of variation at room temperature determined with the 1:20 predilution was < 10.0%, with the highest coefficients of variation found in samples with a low protein concentration or low urine specific gravity. This variability could result in misclassification of samples with UPC ratios close to the thresholds defined by the International Renal Interest Society to classify dogs as nonproteinuric (0.2), borderline proteinuric (0.21 to 0.50), or proteinuric (> 0.51). A proportional bias was found in samples prediluted 1:10, compared with samples prediluted 1:20 or 1:100. At room temperature, the UPC ratio did not significantly increase after 2 and 4 hours. After 12 hours at room temperature and at 4°C, the UPC ratio significantly increased. The UPC ratio did not significantly change during 3 months of storage at -20°C. The intra-assay precision of the UPC ratio was sufficiently low to avoid misclassification of samples, except for values close to 0.2 or 0.5. The optimal predilution ratio for urine creatinine concentration measurement was 1:20. A 1:100 predilution is recommended in samples with a urine specific gravity > 1.030. The UPC ratio must be measured as soon as samples are collected. Alternatively, samples should be immediately frozen to increase their stability and minimize the risk of misclassification of proteinuria.

  20. Designer phenethylamines routinely found in human urine: 2-ethylamino-1-phenylbutane and 2-amino-1-phenylbutane.

    PubMed

    Uralets, Victor; App, Mike; Rana, Sumandeep; Morgan, Stewart; Ross, Wayne

    2014-03-01

    2-Ethylamino-1-phenylbutane (EAPB) and 2-amino-1-phenylbutane (APB) were identified by gas chromatography-mass spectrometry in multiple urine samples submitted for stimulant drug testing and screened positive for amphetamines by enzyme immunoassay. Forty-two samples from all over the USA were found, containing both analytes during a 3-month period May-July 2013. A sports dietary supplement 'CRAZE' has been determined to be one of the sources of EAPB supply. EAPB along with its suggested metabolite APB were detected in a urine sample, obtained from a person known to use 'CRAZE'.

  1. Biomonitoring of 33 Elements in Blood and Urine Samples from Coastal Populations in Sanmen County of Zhejiang Province.

    PubMed

    Zhang, Su-jing; Luo, Ru-xin; Ma, Dong; Zhuo, Xian-yi

    2016-04-01

    To determine the normal reference values of 33 elements, Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, Hg, Li, Mg, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U, V, Zn and Zr, in the blood and urine samples from the general population in Sanmen County of Zhejiang province, a typical coastal area of eastern China. The 33 elements in 272 blood and 300 urine samples were determined by inductively coupled plasma-mass spectrometry (ICP-MS). The normality test of data was conducted using SPSS 17.0 Statistics. The data was compared with other reports. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County were obtained, which of some elements were found to be similar with other reports, such as Co, Cu, Mn and Sr, while As, Cd, Hg and Pb were generally found to be higher than those previously reported. There was a wide variation between the reports from different countries in blood Ba. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County are established, and successfully applied to two poisoning cases.

  2. Detection of tobacco-related biomarkers in urine samples by surface-enhanced Raman spectroscopy coupled with thin-layer chromatography.

    PubMed

    Huang, Rongfu; Han, Sungyub; Li, Xiao Sheryl

    2013-08-01

    The nicotine metabolites, cotinine and trans-3'-hydroxycotinine (3HC) are considered as superior biomarkers for identifying tobacco exposure. More importantly, the ratio of 3HC to cotinine is a good indicator to phenotype individuals for cytochrome P450 2A6 activity and to individualize pharmacotherapy for tobacco addiction. In this paper, a simple, robust and novel method based on surface-enhanced Raman spectroscopy coupled with thin-layer chromatography (TLC) was developed to directly quantify the biomarkers in human urine samples. This is the first time surface-enhanced Raman spectroscopy (SERS) was used to detect cotinine and 3HC in urine samples. The linear dynamic range for the detection of cotinine is from 40 nM to 8 μM while that of 3HC is from 1 μM to 15 μM. The detection limits are 10 nM and 0.2 μM for cotinine and 3HC, respectively. The proposed method was further validated by quantifying the concentration of both cotinine and 3HC in smokers' urine samples. This TLC-SERS method allows the direct detection of cotinine in the urine samples of both active and passive smokers and the detection of 3HC in smokers.

  3. Predictors of short-term treatment outcomes among California's Proposition 36 participants.

    PubMed

    Hser, Yih-Ing; Evans, Elizabeth; Teruya, Cheryl; Huang, David; Anglin, M Douglas

    2007-05-01

    California's voter-initiated Proposition 36 offers non-violent drug offenders community-based treatment as an alternative to incarceration or probation without treatment. This article reports short-term treatment outcomes subsequent to this major shift in drug policy. Data are from 1104 individuals randomly selected from all Proposition 36 participants assessed for treatment in five California counties during 2004. The overall study sample was 30% female, 51% white, 18% Black, 24% Hispanic, and 7% other racial/ethnic groups. The mean+/-SD age was 37+/-10 years. Counties varied considerably in participant characteristics, treatment service intensity, treatment duration, urine testing, and employment and recidivism outcomes, but not in drug use at 3-month follow-up. Controlling for county, logistic regression analysis showed that drug abstinence was predicted by gender (female), employment at baseline (full or part-time), residential (vs. outpatient) stay, low psychiatric severity, frequent urine testing by treatment facility, and more days in treatment. Recidivism was predicted only by shorter treatment duration. Employment predictors included age (younger), gender (male), baseline employment, and lower psychiatric severity. The study findings support drug testing to monitor abstinence and highlight the need to address employment and psychiatric problems among Proposition 36 participants.

  4. Smartphone-based, sensitive µPAD detection of urinary tract infection and gonorrhea.

    PubMed

    Cho, Soohee; Park, Tu San; Nahapetian, Tigran G; Yoon, Jeong-Yeol

    2015-12-15

    The presence of bacteria in urine can be used to monitor the onset or prognosis of urinary tract infection (UTI) and some sexually-transmitted diseases (STDs), such as gonorrhea. Typically, bacteria's presence in urine is confirmed by culturing samples overnight on agar plates, followed by a microscopic examination. Additionally, the presence of Escherichia coli in a urine sample can be indirectly confirmed through assaying for nitrite (generated by reducing nitrate in urine), however this is not sufficiently specific and sensitive. Species/strains identification of bacteria in a urine sample provides insight to appropriate antibiotic treatment options. In this work, a microfluidic paper analytical device (µPAD) was designed and fabricated for evaluating UTI (E. coli) and STD (Neisseria gonorrhoeae) from human urine samples. Anti-E. coli or anti-N. gonorrhoeae antibodies were conjugated to submicron particles then pre-loaded and dried in the center of each paper microfluidic channel. Human urine samples (undiluted) spiked with E. coli or N. gonorrhoeae were incubated for 5 min with 1% Tween 80. The bacteria-spiked urine samples were then introduced to the inlet of paper microfluidic channel, which flowed through the channel by capillary force. Data confirms that proteins were not filtered by μPAD, which is essential for this assay. Urobilin, the component responsible for the yellow appearance of urine and green fluorescence emission, was filtered by μPAD, resulting in significantly minimized false-positive signals. This filtration was simultaneously made during the μPAD assay and no pretreatment/purification step was necessary. Antibody-conjugated particles were immunoagglutinated at the center of the paper channel. The extent of immunoagglutination was quantified by angle-specific Mie scatter under ambient lighting conditions, utilizing a smartphone camera as a detector. The total μPAD assay time was less than 30s. The detection limit was 10 CFU/mL for both E. coli and N. gonorrhoeae, while commercially available gonorrhea rapid kit showed a detection limit of 10(6) CFU/mL. A commercially available nitrite assay test strip also had a detection limit of 10(6) CFU/mL, but this method is not antibody-based and thus not sufficiently specific. By optimizing the particle concentration, we were also able to extend the linear range of the assay up to 10(7) CFU/mL. The proposed prototype will serve as a low-cost, point-of-care, sensitive urinalysis biosensor to monitor UTI and gonorrhea from human urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Temporal variability in urinary levels of drinking water disinfection byproducts dichloroacetic acid and trichloroacetic acid among men

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yi-Xin; Zeng, Qiang; Wang, Le

    Urinary haloacetic acids (HAAs), such as dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA), have been suggested as potential biomarkers of exposure to drinking water disinfection byproducts (DBPs). However, variable exposure to and the short elimination half-lives of these biomarkers can result in considerable variability in urinary measurements, leading to exposure misclassification. Here we examined the variability of DCAA and TCAA levels in the urine among eleven men who provided urine samples on 8 days over 3 months. The urinary concentrations of DCAA and TCAA were measured by gas chromatography coupled with electron capture detection. We calculated the intraclass correlation coefficientsmore » (ICCs) to characterize the within-person and between-person variances and computed the sensitivity and specificity to assess how well single or multiple urine collections accurately determined personal 3-month average DCAA and TCAA levels. The within-person variance was much higher than the between-person variance for all three sample types (spot, first morning, and 24-h urine samples) for DCAA (ICC=0.08–0.37) and TCAA (ICC=0.09–0.23), regardless of the sampling interval. A single-spot urinary sample predicted high (top 33%) 3-month average DCAA and TCAA levels with high specificity (0.79 and 0.78, respectively) but relatively low sensitivity (0.47 and 0.50, respectively). Collecting two or three urine samples from each participant improved the classification. The poor reproducibility of the measured urinary DCAA and TCAA concentrations indicate that a single measurement may not accurately reflect individual long-term exposure. Collection of multiple urine samples from one person is an option for reducing exposure classification errors in studies exploring the effects of DBP exposure on reproductive health. - Highlights: • We evaluated the variability of DCAA and TCAA levels in the urine among men. • Urinary DCAA and TCAA levels varied greatly over a 3-month period. • Single measurement may not accurately reflect personal long-term exposure levels. • Collecting multiple samples from one person improved the exposure classification.« less

  6. Urinary creatinine concentrations in an industrial workforce and comparison with reference values of the general population.

    PubMed

    Bader, Michael; Messerer, Peter; Will, Wolfgang

    2013-08-01

    Urinary creatinine is an important parameter for the adjustment of metabolite concentrations in differently diluted urine specimens, as a reference dimension for biological limit or guidance values and as a selection criterion for spot urine samples in human biomonitoring. While the creatinine output of the general population has been well described in environmental surveys, this study focused specifically on creatinine concentrations in a large industrial workforce in order to compare these data with the general population and to provide a database for the calculation of a reasonable conversion factor between volume-related and creatinine-adjusted data and vice versa. Urinary creatinine was analysed in 6,438 spot urine samples by a photometric assay in the time period between 1989 and 2009. Basic demographic data (age, sex, body weight, body height) and job category (apprentices, skilled craftsmen, skilled chemical workers, foremen, laboratory staff and executives) were considered in a statistical analysis. The median concentration of urinary creatinine in all urine samples was 1.36 g/L with male employees showing significantly higher values (1.37 g/L, n = 6,148 samples) than female employees (1.00 g/L, n = 290) and concentrations ranging from 0.01 up to 9.76 g/L. Age, body mass index and job category were significant influence factors on urinary creatinine. About 92 % of all samples showed creatinine concentrations between 0.3 and 3.0 g/L, a range recommended by the World Health Organization as a criterion for valid spot urine samples. The results of this study correspond well with data from environmental surveys and with recent data from an active workforce in industry with similar sampling strategies. Therefore, a median of 1.4 g creatinine per litre urine seems to be a reasonable value for general calculations and adjustments. The study data also support the validity of the current recommendations by the WHO and several scientific committees and institutions with respect to creatinine limits in spot urine samples for occupational-medical biomonitoring.

  7. Development of isotope labeling liquid chromatography mass spectrometry for mouse urine metabolomics: quantitative metabolomic study of transgenic mice related to Alzheimer's disease.

    PubMed

    Peng, Jun; Guo, Kevin; Xia, Jianguo; Zhou, Jianjun; Yang, Jing; Westaway, David; Wishart, David S; Li, Liang

    2014-10-03

    Because of a limited volume of urine that can be collected from a mouse, it is very difficult to apply the common strategy of using multiple analytical techniques to analyze the metabolites to increase the metabolome coverage for mouse urine metabolomics. We report an enabling method based on differential isotope labeling liquid chromatography mass spectrometry (LC-MS) for relative quantification of over 950 putative metabolites using 20 μL of urine as the starting material. The workflow involves aliquoting 10 μL of an individual urine sample for ¹²C-dansylation labeling that target amines and phenols. Another 10 μL of aliquot was taken from each sample to generate a pooled sample that was subjected to ¹³C-dansylation labeling. The ¹²C-labeled individual sample was mixed with an equal volume of the ¹³C-labeled pooled sample. The mixture was then analyzed by LC-MS to generate information on metabolite concentration differences among different individual samples. The interday repeatability for the LC-MS runs was assessed, and the median relative standard deviation over 4 days was 5.0%. This workflow was then applied to a metabolomic biomarker discovery study using urine samples obtained from the TgCRND8 mouse model of early onset familial Alzheimer's disease (FAD) throughout the course of their pathological deposition of beta amyloid (Aβ). It was showed that there was a distinct metabolomic separation between the AD prone mice and the wild type (control) group. As early as 15-17 weeks of age (presymptomatic), metabolomic differences were observed between the two groups, and after the age of 25 weeks the metabolomic alterations became more pronounced. The metabolomic changes at different ages corroborated well with the phenotype changes in this transgenic mice model. Several useful candidate biomarkers including methionine, desaminotyrosine, taurine, N1-acetylspermidine, and 5-hydroxyindoleacetic acid were identified. Some of them were found in previous metabolomics studies in human cerebrospinal fluid or blood samples. This work illustrates the utility of this isotope labeling LC-MS method for biomarker discovery using mouse urine metabolomics.

  8. Thio-dimethylarsinate is a common metabolite in urine samples from arsenic-exposed women in Bangladesh

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raml, Reingard; Rumpler, Alice; Goessler, Walter

    2007-08-01

    Over the last 6 years, much work on arsenic species in urine samples has been directed toward the determination of the reduced dimethylated arsenic species, DMA(III), because of its high toxicity and perceived key role in the metabolism of inorganic arsenic. Recent work, however, has suggested that DMA(III) may at times have been misidentified because its chromatographic properties can be similar to those of thio-dimethylarsinate (thio-DMA). We analyzed by HPLC-ICPMS (inductively coupled plasma mass spectrometry) urine samples from 75 arsenic-exposed women from Bangladesh with total arsenic concentrations ranging from 8 to 1034 {mu}g As/L and found that thio-DMA was presentmore » in 44% of the samples at concentrations ranging mostly from trace amounts to 24 {mu}g As/L (one sample contained 123 {mu}g As/L). Cytotoxicity testing with HepG2 cells derived from human hepatocarcinoma indicated that thio-DMA was about 10-fold more cytotoxic than dimethylarsinate (DMA). The widespread occurrence of thio-DMA in urine from these arsenic-exposed women suggests that this arsenical may also be present in other urine samples and has so far escaped detection. The work highlights the need for analytical methods providing specific determinations of arsenic compounds in future studies on arsenic metabolism and toxicology.« less

  9. Correlation of the levels of glycosaminoglycans between urine and dried urine in filter paper samples and their stability over time under different storage temperatures.

    PubMed

    Breier, Ana Carolina; Cé, Jaqueline; Coelho, Janice Carneiro

    2014-06-10

    Mucopolysaccharidoses (MPSs) are a group of lysosomal storage diseases caused by the deficiency/absence of enzymes which catalyze the degradation of glycosaminoglycans (GAGs). The use of biological samples dried on filter paper has been increasing because it makes it easy to ship them to reference laboratories. Urinary GAGs are the main biomarkers of MPS and, thus, we studied the correlations of determinations to GAGs and creatinine, as well as compared the GAGs' profile on electrophoresis, between urine and dried urine in filter paper (DUFP) samples. We also assessed the GAG stability over time under different storage temperatures. We quantified the GAG concentration in both sample types and compared the results by Pearson correlation. The results were very similar, with r=0.97 for creatinine and with r=0.94 and r=0.98 for GAGs for controls and patients, respectively, with similar electrophoretic profiles. The GAG stability in DUFP was up to 30days at -20, 4, and 25°C and up to 21days at 37°C. Our proposal assessed urinary GAGs in DUFP and concluded that these samples can be used in the investigation of MPS, replacing urine samples in neonatal screening and monitoring of therapies, due to ease of transportation and storage. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Evaluation of the BinaxNOW® Streptococcus pneumoniae antigen test on fresh, frozen and concentrated urine samples in elderly patients with and without community-acquired pneumonia.

    PubMed

    Saukkoriipi, Annika; Pascal, Thierry; Palmu, Arto A

    2016-02-01

    We evaluated the BinaxNOW® urine antigen test in elderly. For fresh un-concentrated urine samples, the sensitivity for pneumococcal pneumonia was 63% and specificity 97%. After freezing and concentration, the results comparable to positive control line in intensity at 60 min gave high sensitivity (81%) with no loss in specificity (96%). Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Non-invasive optical detection of esophagus cancer based on urine surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Shaohua; Wang, Lan; Chen, Weiwei; Lin, Duo; Huang, Lingling; Wu, Shanshan; Feng, Shangyuan; Chen, Rong

    2014-09-01

    A surface-enhanced Raman spectroscopy (SERS) approach was utilized for urine biochemical analysis with the aim to develop a label-free and non-invasive optical diagnostic method for esophagus cancer detection. SERS spectrums were acquired from 31 normal urine samples and 47 malignant esophagus cancer (EC) urine samples. Tentative assignments of urine SERS bands demonstrated esophagus cancer specific changes, including an increase in the relative amounts of urea and a decrease in the percentage of uric acid in the urine of normal compared with EC. The empirical algorithm integrated with linear discriminant analysis (LDA) were employed to identify some important urine SERS bands for differentiation between healthy subjects and EC urine. The empirical diagnostic approach based on the ratio of the SERS peak intensity at 527 to 1002 cm-1 and 725 to 1002 cm-1 coupled with LDA yielded a diagnostic sensitivity of 72.3% and specificity of 96.8%, respectively. The area under the receive operating characteristic (ROC) curve was 0.954, which further evaluate the performance of the diagnostic algorithm based on the ratio of the SERS peak intensity combined with LDA analysis. This work demonstrated that the urine SERS spectra associated with empirical algorithm has potential for noninvasive diagnosis of esophagus cancer.

  12. Determination of Deoxynivalenol in the Urine of Pregnant Women in the UK

    PubMed Central

    Wells, Liz; Hardie, Laura; Williams, Courtney; White, Kay; Liu, Yunru; De Santis, Barbara; Debegnach, Francesca; Moretti, Georgio; Greetham, Stephanie; Brera, Carlo; Rigby, Alan; Atkin, Stephen; Sathyapalan, Thozhukat

    2016-01-01

    Deoxynivalenol (DON) is one of the most commonly occurring trichothecenes, produced mainly by Fusarium graminearum. Little is known about the effect of DON exposure or the levels of DON exposure that occur during pregnancy. The project aimed to provide data on levels of total DON and de-epoxi Deoxynivalenol (DOM-1) in pregnant human urine samples analysed by liquid chromatography-mass spectrometry (LC-MS). Morning urine samples were collected over two consecutive days from 42 volunteers and associated food consumption was recorded for the 24 h prior to the sample. Spearman’s rho non-parametric test for correlation was used to assess the data. Levels of DON did not differ significantly between day 1 (mean 29.7 ng/mL urine or 40.1 ng DON/mg creatinine) and day 2 (mean 28.7 ng/mL urine or 38.8 ng DON/mg creatinine ng/mL/day) urine samples. The only significant positive correlation was found between total ng DON/mg creatinine and parity (rho = 0.307, n = 42, p < 0.005 two-tailed) and total ng DON/mg creatinine with baked goods on day 1 (rho = 0.532, n = 42, p < 0.0005 two-tailed). This study provides data on the DON levels in pregnancy in this suburban population and reassurance that those levels are within acceptable limits. PMID:27792137

  13. High performance liquid chromatographic method for the determination of cetirizine and ambroxol in human plasma and urine--a boxcar approach.

    PubMed

    Dharuman, J; Vasudhevan, M; Ajithlal, T

    2011-09-01

    A column switching high performance liquid chromatographic method with estimable sensitivity and accuracy was developed for the determination of cetirizine and ambroxol in human plasma using nebivolol as the internal standard. Plasma samples were prepared by liquid-liquid extraction in methylene chloride and a mixture of diethylether (80:20, v/v). The extracted samples were injected into a multifunctional clean-up column Supelcosil LCABZ (50 mm × 4.6 mm, 5 μm particle size) using mobile phase 1 comprising acetonitrile-phosphate buffer (pH 3.5; 20 mM) (20:80, v/v). The eluate of cetirizine and ambroxol were separated to an analytical Kromasil C(8) micro bore column (50 mm × 0.3 mm, 5 μm particle size) via a column switching device. A Kromasil C(18) analytical column (250 mm × 2.1 mm, 5 μm particle size) was used as a separation column. Mobile phase 2 consisting acetonitrile-triethylamine (0.5%) in phosphate buffer (pH 3.5; 20mM) (55:45, v/v) was used for the compound elution. The eluents were detected at 230 nm with photodiode array detector. An aliquot of 150 μl of plasma sample was introduced into the pretreatment column via the auto sampler using mobile phase 1 at a flow rate of 0.5 ml/min, column switching valve being positioned at A. The pretreatment column retained cetirizine, ambroxol and nebivolol (IS) in the column leaving the residual proteins of plasma eluted in void volume and drained out. The switching valve was shifted to position B at 7.5 min. Cetirizine, ambroxol and IS were eluted from the pretreatment column between 7. 5 and 11.5 min and introduced to the concentration column. Finally, cetirizine, ambroxol and IS were introduced to the separation column by switching valve using mobile phase 2 at a flow rate of 0.4 ml/min. During the analysis the pretreatment column was washed for the next analysis and resume to the position A. The total run time was 25 min for a sample. The procedure was repeated for urine analysis also. The method was linear from 2 to 450 ng/ml and 7-300 ng/ml for cetirizine and ambroxol respectively in plasma and 1-500 ng/ml and 5-400 ng/ml, respectively for cetirizine and ambroxol in urine. Intra-day and inter-day precision of cetirizine and ambroxol was below 15% in terms of coefficient of variation and accuracy of cetirizine and ambroxol was ranged from 94 to 101.6% and 91.1 to 100.2%, respectively. The method demonstrated high sensitivity and selectivity and therefore, applied to evaluate pharmacokinetics of cetirizine and ambroxol in healthy human volunteer after a single oral administration. Urine samples obtained from healthy human volunteers and clinical subjects with renal impairment have also been analyzed by the method to compare the elimination pattern. The method was precise and accurate for the estimation of cetirizine and ambroxol both in blood and in urine. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Simultaneous detection of 15 antibiotic growth promoters in bovine muscle, blood and urine by UPLC-MS/MS.

    PubMed

    Wang, Zhi; Shi, Zongwei; Xi, Cunxian; Wang, Guomin; Cao, Shurui; Zhang, Lei; Tang, Bobin; Mu, Zhaode

    2017-12-01

    An analytical method was established for the rapid detection of antibiotic growth promoters (AGPs) in bovine muscle, and bovine blood and bovine urine, using ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). After the addition of an aqueous solution of EDTA-Na 2 , the pH of bovine urine samples was directly adjusted to 5.2 by acetic acid-ammonium acetate and purified by HLB solid-phase extraction cartridge; bovine muscle and bovine blood samples processing were extracted with acetonitrile (ACN) and ACNwater (90:10; v/v) without any purification step. The samples were then centrifuged, concentrated and analysed by UPLC-MS/MS on an ACQUITY UPLC® BEH C18 column using gradient elution. The developed method was validated and mean recovery percentages at three spiked levels were 74-119%, 76-115% and 76-119%, respectively, in bovine muscle, bovine blood, and bovine urine. The relative standard deviation (RSD) ranged from 1.0% to 14.7% in spiked bovine muscle, bovine blood and bovine urine. The limits of detection (LOD) of all analytes were in the ranges 0.11-3.82 µg kg -1 , 0.10-2.49 µg kg -1 and 0.06-4.53 µg kg -1 in bovine muscle, bovine blood, and bovine urine, respectively. The method was sensitive, accurate and was applied to monitor real samples. To the best of our knowledge, this is first method available for simultaneous determination of several classes of APGs in bovine muscle, and bovine blood and bovine urine.

  15. Modulated Raman spectroscopy for enhanced identification of bladder tumor cells in urine samples.

    PubMed

    Canetta, Elisabetta; Mazilu, Michael; De Luca, Anna Chiara; Carruthers, Antonia E; Dholakia, Kishan; Neilson, Sam; Sargeant, Harry; Briscoe, Tina; Herrington, C Simon; Riches, Andrew C

    2011-03-01

    Standard Raman spectroscopy (SRS) is a noninvasive technique that is used in the biomedical field to discriminate between normal and cancer cells. However, the presence of a strong fluorescence background detracts from the use of SRS in real-time clinical applications. Recently, we have reported a novel modulated Raman spectroscopy (MRS) technique to extract the Raman spectra from the background. In this paper, we present the first application of MRS to the identification of human urothelial cells (SV-HUC-1) and bladder cancer cells (MGH) in urine samples. These results are compared to those obtained by SRS. Classification using the principal component analysis clearly shows that MRS allows discrimination between Raman spectra of SV-HUC-1 and MGH cells with high sensitivity (98%) and specificity (95%). MRS is also used to distinguish between SV-HUC-1 and MGH cells after exposure to urine for up to 6 h. We observe a marked change in the MRS of SV-HUC-1 and MGH cells with time in urine, indicating that the conditions of sample collection will be important for the application of this methodology to clinical urine samples.

  16. Biomonitoring of trace elements in urine samples of children from a coal-mining region.

    PubMed

    Santos, Marina Dos; Flores Soares, Maria Cristina; Martins Baisch, Paulo Roberto; Muccillo Baisch, Ana Luíza; Rodrigues da Silva Júnior, Flavio Manoel

    2018-04-01

    Biomonitoring through urine samples is important for evaluating environmental exposure, since urine is the main form of excretion for most chemical elements. Children are considered more vulnerable to adverse environmental conditions, especially children in developing countries. This study aimed to biomonitor trace elements in urine samples in children from a coal-mining region in the extreme south of Brazil. A cross-sectional study was conducted on 96 children between 6 and 11 years of age. Socioeconomic data and urine samples were collected to estimate the concentration of iron, zinc, selenium, lead, and cadmium. The prevalence of metals above the reference values was 52.0% for Se, followed by 15.6% for Zn. The data point toward a vulnerability to adverse environmental conditions in these children. Although the concentrations of the elements did not reveal intoxication cases, biomonitoring should be carried out continuously in order to assess exposure to metals and ensure the health of the population. This article provides data that help determine natural levels of metallic elements in children, specifically in South America, which have not yet been established. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    PubMed

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  18. Monitoring of PAEMs and beta-agonists in urine for a small group of experimental subjects and PAEs and beta-agonists in drinking water consumed by the same subjects.

    PubMed

    Liou, Saou-Hsing; Yang, Gordon C C; Wang, Chih-Lung; Chiu, Yu-Han

    2014-07-30

    This 5-month study contains two parts: (1) to monitor the concentrations of 11 phthalate esters metabolites (PAEMs) and two beta-agonists in human urine samples collected from a small group of consented participants including 16 females and five males; and (2) to analyze the residues of phthalate esters (PAEs) and beta-agonists in various categories of drinking water consumed by the same group of subjects. Each category of human urine and drinking water had 183 samples of its own. The analytical results showed that nine PAEMs were detected in human urine and eight PAEs were detected in drinking water samples. It was found that average concentrations of PAEMs increased as the age increased, but no significant difference between sexes. Further, using the principal component analysis, the loadings of age effect were found to be two times greater than that of gender effect in terms of four DEHP metabolites. Regarding beta-agonists of concern (i.e., ractopamine and salbutamol), they were neither detected in human urine nor drinking water samples in this study. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METAL, PESTICIDE, AND CREATININE ANALYSIS (F10)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...

  20. Mass Spectrometric Rapid Diagnosis of Infectious Diseases.

    DTIC Science & Technology

    1980-01-01

    the analytical procedures to warrant reporting anew the whole analytical procedure. A. Sample Collection and Storage Procedure Urine samples were...positives or false-negatives. Next we have carried out a longitudinal study on urine samples obtained from groups of volunteer subjects vaccinated with...sterilization and storage procedures. 2. Developed new, simpler sample preparation techniques including one to handle tissue culture media. 3. Improved on the

  1. Urine analysis concerning xenon for doping control purposes.

    PubMed

    Thevis, Mario; Piper, Thomas; Geyer, Hans; Schaefer, Maximilian S; Schneemann, Julia; Kienbaum, Peter; Schänzer, Wilhelm

    2015-01-15

    On September 1(st) 2014, a modified Prohibited List as established by the World Anti-Doping Agency (WADA) became effective featuring xenon as a banned substance categorized as hypoxia-inducible factor (HIF) activator. Consequently, the analysis of xenon from commonly provided doping control specimens such as blood and urine is desirable, and first data on the determination of xenon from urine in the context of human sports drug testing, are presented. In accordance to earlier studies utilizing plasma as doping control matrix, urine was enriched to saturation with xenon, sequentially diluted, and the target analyte was detected as supported by the internal standard d6 -cyclohexanone by means of gas chromatography/triple quadrupole mass spectrometry (GC/MS/MS) using headspace injection. Three major xenon isotopes at m/z 128.9, 130.9 and 131.9 were targeted in (pseudo) selected reaction monitoring mode enabling the unambiguous identification of the prohibited substance. Assay characteristics including limit of detection (LOD), intraday/interday precision, and specificity as well as analyte recovery under different storage conditions were determined. Proof-of-concept data were generated by applying the established method to urine samples collected from five patients before, during and after (up to 48 h) xenon-based general anesthesia. Xenon was traceable in enriched human urine samples down to the detection limit of approximately 0.5 nmol/mL. The intraday and interday imprecision values of the method were found below 25%, and specificity was demonstrated by analyzing 20 different blank urine samples that corroborated the fitness-for-purpose of the analytical approach to unequivocally detect xenon at non-physiological concentrations in human urine. The patients' urine specimens returned 'xenon-positive' test results up to 40 h post-anesthesia, indicating the limits of the expected doping control detection window. Since xenon has been considered a prohibited substance according to WADA regulations in September 2014, its analysis from common specimens of routine sports drug testing is desirable. In previous studies, its traceability in whole blood and plasma was shown, and herein a complementary approach utilizing doping control urine samples for the GC/MS/MS analysis of xenon was reported. Copyright © 2014 John Wiley & Sons, Ltd.

  2. Microbial and Antibiotic Susceptibility Profile among Clinical Samples of Patients with Acute Leukemia.

    PubMed

    Abdollahi, Alireza; Hakimi, Faezeh; Doomanlou, Mahsa; Azadegan, Azadeh

    2016-04-01

    Preventing and starting early treatment of infections in patients whose immunity system is weak due to malignancies like leukemia can reduce mortality. This study aimed to determine microbial and antibiotic resistance patterns in clinical samples of patients with acute leukemia to start early treatment before the results of clinical tests are known. In this cross-sectional study, the clinical samples of all patients hospitalized with the diagnosis of acute leukemia were cultured and their antibiogram was evaluated. Then, the data were analyzed by SPSS 18 based on the objectives of the study. Of a total of 2,366 samples, 18.95% were reported to be positive blood samples, 22.96% were reported to be urine samples and 36% wound samples. E. coli was the most common bacteria isolated from the blood and urine cultures (34% in blood, 32% in urine culture) while Staphylococcus Aureus was the most common in the wound culture (35%). The highest level of sensitivity in the organisms with positive blood culture was to Ciprofloxacin, while in positive urine and wound culture was to Imipenem. The highest resistance in blood, urine and wound culture was to Cotrimoxazole. According to results obtained from this study, it is necessary to conduct appropriate studies on this issue in specific conditions in our country. The findings of this study can be used in clinics for more accurate diagnosis, more effective treatment before the results of clinical tests are known and also for prevention of infection in cancer patients.

  3. Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS.

    PubMed

    Barros, Ariane I; Pinheiro, Fernanda C; Amaral, Clarice D B; Lorençatto, Rodolfo; Nóbrega, Joaquim A

    2018-02-01

    This study investigated the capability of High Matrix Introduction (HMI) strategy for analysis of dialysis solution and urine samples using inductively coupled plasma mass spectrometry. The use of HMI enables the direct introduction of urine samples and dialysis solutions 2-fold diluted with 0.14molL -1 HNO 3 . Bismuth, Ge, Ir, Li, Pt, Rh, Sc and Tl were evaluated as internal standards for Al, Ag, As, Be, Cd, Cr, Pb, Sb, Se, Tl, and Hg determination in dialysis solution and As, Cd, Hg and Pb determination in urine samples. Helium collision cell mode (4.5mLmin -1 ) was efficient to overcome polyatomic interferences in As, Se and Cr determinations. Mercury memory effects were evaluated by washing with 0.12molL -1 HCl or an alkaline diluent solution prepared with n-butanol, NH 4 OH, EDTA, and Triton X-100. This later solution was efficient for avoiding Hg memory effects in 6h of analysis. Linear calibration curves were obtained for all analytes and detection limits were lower than maximum amounts allowed by Brazilian legislations. Recoveries for all analytes in dialysis solutions and urine samples ranged from 82% to 125% and relative standard deviations for all elements and samples were lower than 7%. Analysis of control internal urine samples was in agreement with certified values at 95% confidence level (t-test; p < 0.05). Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Comparison of population iodine estimates from 24-hour urine and timed-spot urine samples.

    PubMed

    Perrine, Cria G; Cogswell, Mary E; Swanson, Christine A; Sullivan, Kevin M; Chen, Te-Ching; Carriquiry, Alicia L; Dodd, Kevin W; Caldwell, Kathleen L; Wang, Chia-Yih

    2014-04-01

    Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr × predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare with the reference standard 24-hour UIE. Volunteers aged 18-39 years collected all their urine samples for 24 hours (n=400). Voids from morning, afternoon, evening, overnight, and a composite 24-hour sample were analyzed for iodine. We calculated median observed 24-hour UIE and 24-hour UIC, and spot UIC, I/Cr, and two measures of estimated UIE calculated using predicted 24-hour Cr from published estimates by Kesteloot and Joosens (varies by age and sex) and published equations by Mage et al. (varies by age, sex, race, and anthropometric measures). We examined mean differences and relative difference across iodine excretion levels using Bland-Altman plots. Median 24-hour UIE was 173.6 μg/day and 24-hour UIC was 144.8 μg/L. From timed-spot urine samples, estimates were: UIC 147.3-156.2 μg/L; I/Cr 103.6-114.3 μg/g, estimated 24-hour UIE (Kesteloot and Joosens) 145.7-163.3 μg/day; and estimated 24-hour UIE (Mage) 176.5-187.7 μg/day. Iodine measures did not vary consistently by timing of spot urine collection. Compared with observed 24-hour UIE, on average, estimated (Mage) 24-hour UIE was not significantly different, while estimated 24-hour UIE (Kesteloot and Joosens) was significantly different for some ethnicity/sex groups. Compared with 24-hour UIC, on average, spot UIC did not differ. Estimates of UIC, I/Cr, and estimated 24-hour UIE (I/Cr × predicted 24-hour Cr) from spot urine samples should not be used interchangeably. Estimated 24-hour UIE, where predicted 24-hour Cr varies by age, sex, ethnicity, and anthropometric measures and was calculated with prediction equations using data from the sample, was more comparable to observed 24-hour UIE than when predicted 24-hour Cr was from published estimates from a different population. However, currently no cutoffs exist to interpret population estimated 24-hour UIE values.

  5. Self-Collected versus Clinician-Collected Sampling for Chlamydia and Gonorrhea Screening: A Systemic Review and Meta-Analysis

    PubMed Central

    Lunny, Carole; Taylor, Darlene; Hoang, Linda; Wong, Tom; Gilbert, Mark; Lester, Richard; Krajden, Mel; Ogilvie, Gina

    2015-01-01

    Background The increases in STI rates since the late 1990s in Canada have occurred despite widespread primary care and targeted public health programs and in the setting of universal health care. More innovative interventions are required that would eliminate barriers to STI testing such as internet-based or mail-in home and community service testing for patients that are hard to reach, who refuse to go for clinician-based testing, or who decline an examination. Jurisdictions such as New Zealand and some American states currently use self-collected sampling, but without the required evidence to determine whether self-collected specimens are as accurate as clinician-collected specimens in terms of chlamydia and gonorrhea diagnostic accuracy. The objective of the review is to compare self-collected vaginal, urine, pharyngeal and rectal samples to our reference standard - clinician-collected cervical, urethral, pharyngeal and rectal sampling techniques to identify a positive specimen using nucleic acid amplification test assays. Methods The hierarchical summary receiver operating characteristic and the fixed effect models were used to assess the accuracy of comparable specimens that were collected by patients compared to clinicians. Sensitivity and specificity estimates with 95% confidence intervals (CI) were reported as our main outcome measures. Findings We included 21 studies based on over 6100 paired samples. Fourteen included studies examined chlamydia only, 6 compared both gonorrhea and chlamydia separately in the same study, and one examined gonorrhea. The six chlamydia studies comparing self-collection by vaginal swab to a clinician-collected cervical swab had the highest sensitivity (92%, 95% CI 87-95) and specificity (98%, 95% CI 97-99), compared to other specimen-types (urine/urethra or urine/cervix). Six studies compared urine self-samples to urethra clinician-collected samples in males and produced a sensitivity of 88% (95% CI 83-93) and a specificity of 99% (95% CI 0.94-0.99). Taking into account that urine samples may be less sensitive than cervical samples, eight chlamydia studies that compared urine self-collected verses clinician-collected cervical samples had a sensitivity of 87% (95% CI 81-91) and high specificity of 99% (95% CI 0.98-1.00). For gonorrhea testing, self-collected urine samples compared to clinician-collected urethra samples in males produced a sensitivity of 92% (95% CI 83-97) and specificity of 99% (95% CI 0.98-1.00). Conclusion The sensitivity and specificity of vaginal self-collected swabs compared to swabs collected by clinicians supports the use of vaginal swab as the recommended specimen of choice in home-based screening for chlamydia and gonorrhea. Urine samples for gonorrhea collected by men had comparably high sensitivity and specificity, so could be recommended as they can be left at room temperature for several days, allowing for the possibility of mail-in home-based testing. In populations that may not go for testing at all, do not have the option of clinical testing, or who refuse a clinical examination, self-collected screening would be a good alternative. We recommend that guidelines on how to self-collect gonorrhea and chlamydia urine, vaginal, rectal and pharyngeal specimens be published. PMID:26168051

  6. Use of immunoblotting to detect Aspergillus fumigatus antigen in sera and urines of rats with experimental invasive aspergillosis.

    PubMed Central

    Yu, B; Niki, Y; Armstrong, D

    1990-01-01

    Immunoblotting was used to detect Aspergillus fumigatus antigen in sera and urines of immunosuppressed rats experimentally infected with A. fumigatus. Organisms were administered by both intravenous and intratracheal injections. Intravenously infected rats developed disseminated aspergillosis, but intratracheally infected rats developed pulmonary disease only. Fungal cultures of blood and urine samples from infected rats were negative. In the urines of intravenously infected rats, antigen was detected 24 to 48 h after infection; in the urines of intratracheally infected animals, antigen was detected on days 4 to 5 after infection. Antigen in serum was detected later than antigen in urine was. Following sodium dodecyl sulfate-polyacrylamide gel electrophoresis and immunoblotting of serum and urine samples, the most strongly reacting antigenic materials were found in the 88-, 40-, 27-, and 20-kilodalton regions. These dominant antigens appeared to be the same as those of control antigens prepared from A. fumigatus grown in vitro. Rabbit antiserum to Aspergillus filtrate antigen was found to be more immunoreactive than antiserum to mycelial or conidial antigen. No mycelium-specific antigens were detected. Images PMID:2199519

  7. Determination of delorazepam in urine by solid-phase microextraction coupled to high performance liquid chromatography.

    PubMed

    Aresta, Antonella; Monaci, Linda; Zambonin, Carlo Giorgio

    2002-06-01

    An SPME-HPLC-UV method for the determination of delorazepam, a representative benzodiazepine, in spiked human urine samples was developed for the first time. The performances of two commercially available fibers, a carbowax/templated resin (Carbowax/TPR-100) and a polydimethylsiloxane/divinylbenzene (PDMS/DVB), were compared, indicating the latter as the most suitable for urine samples analysis. All the aspects influencing adsorption (extraction time, pH, temperature, salt addition) and desorption (desorption and injection time, desorption solvent mixture composition) of the analyte on the fiber have been investigated. In particular, short extraction times were necessary to reach the equilibrium and very short desorption times were employed. The procedure required simple sample pre-treatment and was able to detect 5 ng/ml in spiked urine, regardless of the complexity of the matrix.

  8. Development of an Inline Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Banelle R.

    2008-01-01

    Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

  9. Feline urine metabolomic signature: characterization of low-molecular-weight substances in urine from domestic cats.

    PubMed

    Rivera-Vélez, Sol-Maiam; Villarino, Nicolas F

    2018-02-01

    Objectives This aim of this study was to characterize the composition and content of the feline urine metabolome. Methods Eight healthy domestic cats were acclimated at least 10 days before starting the study. Urine samples (~2 ml) were collected by ultrasound-guided cystocentesis. Samples were centrifuged at 1000 × g for 8 mins, and the supernatant was analyzed by gas chromatography/time-of-flight mass spectrometery. The urine metabolome was characterized using an untargeted metabolomics approach. Results Three hundred and eighteen metabolites were detected in the urine of the eight cats. These molecules are key components of at least 100 metabolic pathways. Feline urine appears to be dominated by carbohydrates, carbohydrate conjugates, organic acid and derivatives, and amino acids and analogs. The five most abundant molecules were phenaceturic acid, hippuric acid, pseudouridine phosphate and 3-(4-hydroxyphenyl) propionic acid. Conclusions and relevance This study is the first to characterize the feline urine metabolome. The results of this study revealed the presence of multiple low-molecular-weight substances that were not known to be present in feline urine. As expected, the origin of the metabolites detected in urine was diverse, including endogenous compounds and molecules biosynthesized by microbes. Also, the diet seemed to have had a relevant role on the urine metabolome. Further exploration of the urine metabolic phenotype will open a window for discovering unknown, or poorly understood, metabolic pathways. In turn, this will advance our understanding of feline biology and lead to new insights in feline physiology, nutrition and medicine.

  10. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING URINE SAMPLES FOR ANALYSIS OF HYDROXY POLYCYCLIC AROMATIC HYDROCARBONS, PENTACHLOROPHENOL AND 2,4-D (SOP-5.21)

    EPA Science Inventory

    The method for extracting and preparing urine samples for analysis of hydroxy-polycyclic aromatic hydrocarbons, pentachlorophenol and 2,4-D is summarized in this SOP. It covers the extraction, concentration and methylation of samples that are to be analyzed by gas chromatography/...

  11. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE AND SHIPMENT OF URINE SAMPLES FOR SELECTED METALS AND PESTICIDES (UA-F-20.1)

    EPA Science Inventory

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected for the NHEXAS Arizona project. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed ...

  12. Urine human papillomavirus prevalence in women with high-grade cervical lesions.

    PubMed

    Nicolau, P; Mancebo, G; Agramunt, S; Solé-Sedeño, J M; Bellosillo, B; Muset, M M; Lloveras, B; Alameda, F; Carreras, R

    2014-12-01

    To determine the prevalence of human papillomavirus (HPV) in urine samples from women with high-grade cervical lesions. Secondary objectives are to identify the influence of socio-demographic factors and the different genotypes with urinary HPV positivity. 75 women with a positive biopsy for CIN2+ were included in the study from October 2010 to July 2011. A sample of urine was collected immediately before conization at the outpatient clinic. We analyzed the presence of HPV using a PCR technique. The mean age of the patients was 34.8 years (range 24 to 61). All patients had histological CIN2+, of whom 54.67% had CIN3. The prevalence of HPV in urine test was 58.82% in CIN2 population versus 78.05% in CIN3 patients (p 0.072). 31 different genotypes were found. The most frequent HPV genotype was 16-HPV, which was identified in 58% of women with positive HPV-DNA in urine samples. No demographic characteristics were significantly associated to urinary HPV prevalence. Most of the patients with CIN2+ showed positive results for urine HPV test. The prevalence of positive urinary HPV test was higher for patients with CIN3. HPV urine detection could be considered as an acceptable option for high-risk population who skip regular screening programs. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Comparison of Zika virus (ZIKV) RNA detection in plasma, whole blood and urine - Case series of travel-associated ZIKV infection imported to Italy, 2016.

    PubMed

    Rossini, Giada; Gaibani, Paolo; Vocale, Caterina; Cagarelli, Roberto; Landini, Maria Paola

    2017-09-01

    The capability to detect ZIKV RNA is of crucial importance for cases confirmation. However, due to the short-lived viremia, the detection of ZIKV RNA in plasma/serum is challenging for samples collected more than one week after onset of clinical illness. We compared the window time and detection rate of ZIKV RNA in different specimen types (plasma, whole blood and urine) collected simultaneously at several times post-symptom onset. We examined the presence of ZIKV RNA in matched specimens of whole blood, plasma and urine collected in the same date (3-28 days after symptom onset) from 10 ZIKV infected patients. ZIKV RNA was found in plasma as late as 10 days after symptoms onset and tested positive in all 5 (100%) and in 2 of 6 (33,3%) plasma samples collected 1-5 and 6-10 days after symptoms onset, respectively. ZIKV RNA was positive in urine through the 21st day after symptom onset; the detection rate of ZIKV RNA in urine samples was 100% (11/11) for samples collected 1-10 days from symptoms onset, decreasing at later times of sampling. The detection rate of ZIKV RNA in whole blood was comparable to that in urine samples but extended the window of detection of ZIKV RNA up to 26 days after symptom onset. Our results highlight the usefulness of simultaneously testing multiple specimen types in order to extend the rate and the time frame of ZIKV RNA detection, increasing the possibility of cases confirmation through direct diagnosis in convalescence-phase of infection, supplementing serological data which are often difficult to interpret. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  14. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    PubMed

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.

  15. Validation of a multi-analyte HPLC-DAD method for determination of uric acid, creatinine, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid and 2-methylhippuric acid in human urine.

    PubMed

    Remane, Daniela; Grunwald, Soeren; Hoeke, Henrike; Mueller, Andrea; Roeder, Stefan; von Bergen, Martin; Wissenbach, Dirk K

    2015-08-15

    During the last decades exposure sciences and epidemiological studies attracts more attention to unravel the mechanisms for the development of chronic diseases. According to this an existing HPLC-DAD method for determination of creatinine in urine samples was expended for seven analytes and validated. Creatinine, uric acid, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid, and 2-methylhippuric acid were separated by gradient elution (formate buffer/methanol) using an Eclipse Plus C18 Rapid Resolution column (4.6mm×100mm). No interfering signals were detected in mobile phase. After injection of blank urine samples signals for the endogenous compounds but no interferences were detected. All analytes were linear in the selected calibration range and a non weighted calibration model was chosen. Bias, intra-day and inter-day precision for all analytes were below 20% for quality control (QC) low and below 10% for QC medium and high. The limits of quantification in mobile phase were in line with reported reference values but had to be adjusted in urine for homovanillic acid (45mg/L), niacinamide 58.5(mg/L), and indole-3-acetic acid (63mg/L). Comparison of creatinine data obtained by the existing method with those of the developed method showing differences from -120mg/L to +110mg/L with a mean of differences of 29.0mg/L for 50 authentic urine samples. Analyzing 50 authentic urine samples, uric acid, creatinine, hippuric acid, and 2-methylhippuric acid were detected in (nearly) all samples. However, homovanillic acid was detected in 40%, niacinamide in 4% and indole-3-acetic acid was never detected within the selected samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Elimination of 7-aminoclonazepam in urine after a single dose of clonazepam.

    PubMed

    Negrusz, Adam; Bowen, Andrew M; Moore, Christine M; Dowd, Sheila M; Strong, Mary Jane; Janicak, Philip G

    2003-08-01

    The objective of this paper was to determine how long after administration of benzodiazepine clonazepam (CLO), its major metabolite 7-aminoclonazepam (7-ACLO) could be detected in urine collected from 10 healthy volunteers who received a single 3-mg dose of Klonopin (clonazepam). Such data would be of great importance to law enforcement agencies trying to determine the best time interval for urine collection from a victim of drug-facilitated sexual assault in order to reveal drug use. A highly sensitive NCI-GC-MS method for the simultaneous quantitation of CLO and its major metabolite 7-ACLO in urine was developed and validated. The following urine samples were collected from each volunteer: one before CLO administration, and 6 h, and 1, 3, 5, 8, 10, 14, 21 and 28 days after. All urine samples (1 mL) were extracted following addition of the internal standard (D(5)-diazepam) and enzymatic hydrolysis ( beta-glucuronidase) using solid-phase extraction columns. Standard curves for CLO (500-4000 pg x mL(-1)) and 7-ACLO (50-2000 pg x mL(-1)) were prepared by spiking aliquots of negative urine. The urine from every subject was still positive for 7-ACLO 14 days after administration of the drug. Eight of the ten volunteers had measurable amounts of the metabolite 21 days after administration. One volunteer was still positive 28 days after administration. Six of the volunteers had urine concentrations of 7-ACLO that peaked at 1 day after administration. One volunteer had the highest concentration of 7-ACLO at 3 days, two volunteers at 5 days, and one at 8 days. The range of concentrations detected was from 73.0 pg x mL(-1) to 183.2 ng x mL(-1). CLO was not detected in any of the samples.

  17. Characterization of phthalates exposure and risk for cosmetics and perfume sales clerks.

    PubMed

    Huang, Po-Chin; Liao, Kai-Wei; Chang, Jung-Wei; Chan, Shiou-Hui; Lee, Ching-Chang

    2018-02-01

    High levels of phthalates in name-brand cosmetics products have raised concerns about phthalate exposure and the associated risk for cosmetics sales clerks. We assessed the exposure and risk of phthalates in 23 cosmetics, 4 perfume, and 9 clothing department store sales clerks. We collected 108 urine samples pre- and post-shift and analyzed for phthalate monoesters through liquid chromatography-electrospray ionization-tandem mass spectrometry. Phthalates in 32 air samples were collected and analyzed through gas chromatography-mass spectrometry. Demographic characteristics and information on the exposure scenarios were obtained through questionnaires. Principal component analysis, cluster and risk analysis were applied to identify the exposure profile and risk of phthalate. Median post-shift levels of urinary mono-2-ethylhexyl phthalate (MEHP) and monomethyl phthalate (MMP) were significantly higher than the corresponding pre-shift levels in cosmetics group (53.3 vs. 30.9 μg/g-c for MEHP; 34.4 vs. 22.5 μg/g-c for MMP; both P < 0.05) and the post-shift levels of urinary MMP was significantly higher than the corresponding pre-shift levels in perfume group (26.6 vs. 14.9 μg/g-c, P < 0.05). Median levels of air diethyl phthalate (DEP) in cosmetics (1.77 μg/m 3 ) and perfume (1.75 μg/m 3 ) groups and di-(2-ethylhexyl) phthalate (DEHP) in perfume group (6.98 μg/m 3 ) were higher than those in clothing group (DEP: 0.89; DEHP: 2.16 μg/m 3 ). Over half of cosmetic (70%) and perfume sale clerks had exceeded cumulative risk of phthalate exposure for anti-androgenic effect. We concluded that cosmetic and perfume workers had increased risks of reproductive or hepatic effects for DBP and DEHP exposure. We suggest that not only inhalation but dermal exposure is important route of phthalate exposure for cosmetics and perfume workers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriguez, Branelle R.; Broyan, James Lee, Jr.

    2008-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  19. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle R.; Broyan, James Lee, Jr.

    2009-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  20. RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.; Culligan, B.

    2008-08-27

    The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared tomore » NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.« less

  1. Development and validation of an ultra-performance liquid chromatography quadrupole time of flight mass spectrometry method for rapid quantification of free amino acids in human urine.

    PubMed

    Joyce, Richard; Kuziene, Viktorija; Zou, Xin; Wang, Xueting; Pullen, Frank; Loo, Ruey Leng

    2016-01-01

    An ultra-performance liquid chromatography quadrupole time of flight mass spectrometry (UPLC-qTOF-MS) method using hydrophilic interaction liquid chromatography was developed and validated for simultaneous quantification of 18 free amino acids in urine with a total acquisition time including the column re-equilibration of less than 18 min per sample. This method involves simple sample preparation steps which consisted of 15 times dilution with acetonitrile to give a final composition of 25 % aqueous and 75 % acetonitrile without the need of any derivatization. The dynamic range for our calibration curve is approximately two orders of magnitude (120-fold from the lowest calibration curve point) with good linearity (r (2) ≥ 0.995 for all amino acids). Good separation of all amino acids as well as good intra- and inter-day accuracy (<15 %) and precision (<15 %) were observed using three quality control samples at a concentration of low, medium and high range of the calibration curve. The limits of detection (LOD) and lower limit of quantification of our method were ranging from approximately 1-300 nM and 0.01-0.5 µM, respectively. The stability of amino acids in the prepared urine samples was found to be stable for 72 h at 4 °C, after one freeze thaw cycle and for up to 4 weeks at -80 °C. We have applied this method to quantify the content of 18 free amino acids in 646 urine samples from a dietary intervention study. We were able to quantify all 18 free amino acids in these urine samples, if they were present at a level above the LOD. We found our method to be reproducible (accuracy and precision were typically <10 % for QCL, QCM and QCH) and the relatively high sample throughput nature of this method potentially makes it a suitable alternative for the analysis of urine samples in clinical setting.

  2. Quantitation of iothalamate in urine and plasma using liquid chromatography electrospray tandem mass spectrometry (HPLC-ESI-MS/MS).

    PubMed

    Molinaro, Ross J; Ritchie, James C

    2010-01-01

    The following chapter describes a method to measure iothalamate in plasma and urine samples using high performance liquid chromatography combined with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methanol and water are spiked with the internal standard (IS) iohexol. Iothalamate is isolated from plasma after IS spiked methanol extraction and from urine by IS spiked water addition and quick-spin filtration. The plasma extractions are dried under a stream of nitrogen. The residue is reconstituted in ammonium acetate-formic acid-water. The reconstituted plasma and filtered urine are injected into the HPLC-ESI-MS/MS. Iothalamate and iohexol show similar retention times in plasma and urine. Quantification of iothalamate in the samples is made by multiple reaction monitoring using the hydrogen adduct mass transitions, from a five-point calibration curve.

  3. Determination of (210)Po in drinking water and urine samples using copper sulfide microprecipitation.

    PubMed

    Guérin, Nicolas; Dai, Xiongxin

    2014-06-17

    Polonium-210 ((210)Po) can be rapidly determined in drinking water and urine samples by alpha spectrometry using copper sulfide (CuS) microprecipitation. For drinking water, Po in 10 mL samples was directly coprecipitated onto the filter for alpha counting without any purification. For urine, 10 mL of sample was heated, oxidized with KBrO3 for a short time (∼5 min), and subsequently centrifuged to remove the suspended organic matter. The CuS microprecipitation was then applied to the supernatant. Large batches of samples can be prepared using this technique with high recoveries (∼85%). The figures of merit of the methods were determined, and the developed methods fulfill the requirements for emergency and routine radioassays. The efficiency and reliability of the procedures were confirmed using spiked samples.

  4. The ultimate veal calf reference experiment: hormone residue analysis data obtained by gas and liquid chromatography tandem mass spectrometry.

    PubMed

    Nielen, Michel W F; Lasaroms, Johan J P; Essers, Martien L; Sanders, Marieke B; Heskamp, Henri H; Bovee, Toine F H; van Rhijn, J Hans; Groot, Maria J

    2007-03-14

    A lifetime controlled reference experiment has been performed using 42 veal calves, 21 males and 21 females which were fed and housed according to European regulations and common veterinary practice. During the experiment feed, water, urine and hair were sampled and feed intake and growth were monitored. Thus for the first time residue analysis data were obtained from guaranteed lifetime-untreated animals. The analysis was focused on the natural hormones estradiol and testosterone and their metabolites, on 17beta- and 17alpha-nortestosterone, on 17beta- and 17alpha-boldenone and androsta-1,4-diene-3,17-dione (ADD), and carried out by gas chromatography tandem mass spectrometry (GC/MS/MS), an estrogen bioassay and liquid chromatography (LC) MS/MS. Feed, water and hair samples were negative for the residues tested. Female calf urines showed occasionally low levels of 17alpha-estradiol and 17alpha-testosterone. On one particular sampling day male veal calf urines showed very high levels of 17alpha-testosterone (up to 1000 ng mL(-1)), accompanied by lower levels of estrone and 17beta-testosterone. Despite these extreme levels of natural testosterone, 17beta-boldenone was never detected in the same urine samples; even 17alpha-boldenone and ADD were only occasionally beyond CCalpha (maximum levels 2.7 ng mL(-1)). The data from this unique experiment provide a set of reference values for steroid hormones in calf urine and demonstrate that 17beta-boldenone is not a naturally occurring compound in urine samples.

  5. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...

  6. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...

  7. Rapid and visual detection of Leptospira in urine by LigB-LAMP assay with pre-addition of dye.

    PubMed

    Ali, Syed Atif; Kaur, Gurpreet; Boby, Nongthombam; Sabarinath, T; Solanki, Khushal; Pal, Dheeraj; Chaudhuri, Pallab

    2017-12-01

    Leptospirosis is considered to be the most widespread zoonotic disease caused by pathogenic species of Leptospira. The present study reports a novel set of primers targeting LigB gene for visual detection of pathogenic Leptospira in urine samples through Loop-mediated isothermal amplification (LAMP). The results were recorded by using Hydroxyl napthol blue (HNB), SYBR GREEN I and calcein. Analytical sensitivity of LAMP was as few as 10 leptospiral organisms in spiked urine samples from cattle and dog. LigB gene based LAMP, termed as LigB-LAMP, was found 10 times more sensitive than conventional PCR. The diagnostic specificity of LAMP was 100% when compared to SYBR green qPCR for detection of Leptospira in urine samples. Though qPCR was found more sensitive, the rapidity and simplicity in setting LAMP test followed by visual detection of Leptospira infection in clinical samples makes LigB-LAMP an alternative and favourable diagnostic tool in resource poor setting. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. [Cortisol/creatinine ratio in urine (UCC) of healthy cats].

    PubMed

    Zimmer, C; Reusch, C E

    2003-07-01

    In 31 healthy cats urine samples were taken to determine the cortisol/creatinine ratio (UCC) during hospitalisation and at home. The UCC of the samples, which had been taken in the clinic, was significantly higher (0-19 x 10(-6), Median 3 x 10(-6)) than the one of the samples taken at home (0-4 x 10(-6), Median 1 x 10(-6)). The parameter was neither influenced by the cat's age, sex or the fact that the cat stayed inside or outside, nor by the degree of visible agitation. Assay validation achieved good results regarding precision and accuracy of the measuring of cortisol and creatinine in the urine. The study shows that stress--caused by the visit to the veterinarian--can provoke a significant increase of UCC. Therefore, the parameter should be determined only from urine samples taken at home. Furthermore, it is important to notice that cortisol metabolites are measured in varying degree with the different assays. Therefore, it is inevitable that each laboratory generates its own reference values.

  9. An investigation of normal urine with a creatinine concentration under the cutoff of 20 mg/dL for specimen validity testing in a toxicology laboratory.

    PubMed

    Holden, Brad; Guice, Erica A

    2014-05-01

    In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.

  10. [Detection of West Nile virus in human samples: follow-up studies during the 2015 seasonal period].

    PubMed

    Nagy, Anna; Nagy, Orsolya; Bán, Enikő; Molnár, Eszter; Müller, Zsófia; Orbán, Márton; Kecskés, Borbála; Harsányi, Emese Henriett; Kővágó, Levente; Jobbágy, Lajos; Németh, Zoltán; Várnai, Zsuzsanna; Takács, Mária

    2017-05-01

    West Nile virus, a mosquito-borne viral zoonosis is responsible for human infections in Hungary. Laboratory diagnosis is based on serological tests, however the application of molecular methods has been appreciated. The aim of the study was to investigate blood, cerebrospinal-fluid and urine samples of acutely ill patients and to follow-up PCR positive cases to ascertain the length of virus excretion. Clinical specimens were examined by indirect-immunofluorescent, haemagglutination-inhibition, two PCR tests and Sanger-sequencing. Virus isolation in case of two patients was successful. A follow-up study could be carried out in case of 5 patients. Viral nucleic acid was detectable in urine even for several weeks after symptom onset and viral RNA was present at higher concentration compared with other samples. PCR analysis of urine could provide useful epidemiological and diagnostic information. Therefore, it is recommended to collect urine samples in order to supplement the serological diagnosis. Orv Hetil. 2017; 158(20): 791-796.

  11. Genotyping of Leptospira directly in urine samples of cattle demonstrates a diversity of species and strains in Brazil.

    PubMed

    Hamond, C; Pestana, C P; Medeiros, M A; Lilenbaum, W

    2016-01-01

    The aim of this study was to identify Leptospira in urine samples of cattle by direct sequencing of the secY gene. The validity of this approach was assessed using ten Leptospira strains obtained from cattle in Brazil and 77 DNA samples previously extracted from cattle urine, that were positive by PCR for the genus-specific lipL32 gene of Leptospira. Direct sequencing identified 24 (31·1%) interpretable secY sequences and these were identical to those obtained from direct DNA sequencing of the urine samples from which they were recovered. Phylogenetic analyses identified four species: L. interrogans, L. borgpetersenii, L. noguchii, and L. santarosai with the most prevalent genotypes being associated with L. borgpetersenii. While direct sequencing cannot, as yet, replace culturing of leptospires, it is a valid additional tool for epidemiological studies. An unexpected finding from this study was the genetic diversity of Leptospira infecting Brazilian cattle.

  12. Enantioselective extraction of (+)-(S)-citalopram and its main metabolites using a tailor-made stir bar chiral imprinted polymer for their LC-ESI-MS/MS quantitation in urine samples.

    PubMed

    Unceta, Nora; Gómez-Caballero, Alberto; García, Deiene; Díaz, Goretti; Guerreiro, Antonio; Piletsky, Sergey; Goicolea, M Aránzazu; Barrio, Ramón J

    2013-11-15

    This paper reports the application of a chiral imprinted polymer (CIP)-coated stir bar for the selective extraction of (+)-(S)-citalopram (SCIT) and its main metabolites, (+)-(S)-desmethylcitalopram (SDCIT) and (+)-(S)-didesmethylcitalopram (SDDCIT), from urine samples. The developed device has been demonstrated to be capable of selectively extracting the three target analytes from urine samples without saturating the imprinted sites. A CIP-coated stir bar sorptive extraction procedure (CIP-SBSE) is proposed for the isolation of SCIT, SDCIT and SDDCIT followed by their subsequent analysis using liquid chromatography ion trap mass spectrometry (LC-ITMS). Deuterated SCIT-d6 was used as an internal standard. The method was validated using a standard procedure, which revealed that a quantification of 5 ng mL(-1) was obtained in urine samples and that the accuracy and precision were within the established values while no matrix effect was observed. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    PubMed

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  14. Measurement by reversed-phase high-performance liquid chromatography of malondialdehyde in normal human urine following derivatisation with 2,4-dinitrophenylhydrazine.

    PubMed

    Korchazhkina, Olga; Exley, Christopher; Andrew Spencer, Stephen

    2003-09-05

    A selective and sensitive method based on derivatisation with 2,4-dinitrophenylhydrazine (DNPH) and consecutive HPLC gradient separation is described for the determination of malondialdehyde (MDA) in urine. Preparation of urine samples involved a one-step derivatisation/extraction procedure. Separation was achieved using a Waters SymmetryC(18) column (3.9 x 150 mm) and linear gradient of acetonitrile in water (from 30% to 70% in 30 min). The overall detection limit of the method was 56 nM of MDA in urine. The recovery of MDA was 94.3+/-8.6%. MDA in urine of healthy volunteers, measured using the method of standard additions, was 0.019+/-0.012 microM/mmol creatinine. MDA in the same samples measured using the 2-thiobarbituric acid (TBA) assay was 0.181+/-0.063 microM/mmol creatinine. We demonstrate that the commonly used TBA assay in conjunction with HPLC may overestimate the MDA concentration in human urine by almost 10-fold.

  15. Analyte variations in consecutive 24-hour urine collections in children.

    PubMed

    Ellison, Jonathan S; Hollingsworth, John M; Langman, Craig B; Asplin, John R; Schwaderer, Andrew L; Yan, Phyllis; Bierlein, Maggie; Barraza, Mark A; Defoor, William R; Figueroa, T Ernesto; Jackson, Elizabeth C; Jayanthi, Venkata R; Johnson, Emilie K; Joseph, David B; Shnorhavorian, Margarett

    2017-12-01

    The metabolic evaluation of children with nephrolithiasis begins with a 24-h urine collection. For adults, the diagnostic yield increases with consecutive collections; however, little is known regarding the variability of multiple 24-h studies in the pediatric population. We sought to evaluate the variability of consecutive 24-h urine collection in children through a multi-institutional study hypothesizing that compared with a single collection, consecutive 24-h urine collections would reveal a greater degree of clinically useful information in the evaluation of children at risk for nephrolithiasis. Including data from six institutions, we identified children less than 18 years of age considered at risk for recurrent nephrolithiasis, undergoing metabolic evaluation. We evaluated a subset of patients performing two collections with urine creatinine varying by 10% or less during a 7-day period. Discordance between repeat collections based on normative urine chemistry values was evaluated. A total of 733 children met inclusion criteria, and in over a third both urine calcium and urine volume differed by 30% or more between samples. Urine oxalate demonstrated greater variation between collections in children <5 years than among older children (p = 0.030) while variation in other parameters did not differ by age. Discordance between repeat samples based on normative values was most common for urine oxalate (22.5%) and the derived relative supersaturation ratios for both calcium phosphate (25.1%) and calcium oxalate (20.5%). The proportion of discordant samples, based on normative thresholds, as well as variability greater ≥30% and 50%, respectively, are shown in the table. Our analysis indicates that stone risk in as many as one in four children may be misclassified if normative values of only a single 24-h urine are used. In light of these findings, repeat 24-h urine collections prior to targeted intervention to modify stone risk are advised to increase diagnostic yield in children at risk for nephrolithiasis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  16. Reactivation of latent herpes viruses in cosmonauts during a soyuz taxi mission

    NASA Astrophysics Data System (ADS)

    Mehta, Satish K.; Pierson, Duane L.

    2007-09-01

    The hypothesis tested by this project is that space flight increases the incidence and duration of herpes virus reactivation and shedding in saliva. Saliva, urine, and blood samples were collected from 3 crew members who participated in a 14-day Odessa Soyuz taxi mission. Saliva samples were collected before, during, and after the mission, and blood and urine were collected before and after the mission. The saliva and urine samples were analyzed using the polymerase chain reaction to detect the presence of 3 important herpes viruses. Epstein-Barr virus (EBV) and varicella-zoster virus (VZV) were tested in saliva, and cytomegalovirus (CMV) was measured in urine samples. Plasma antibodies levels to these viruses were determined by enzyme-linked immunosorbent assay before and after flight. EBV reactivated before, during, and after flight; CMV reactivated before and after flight; and VZV reactivated during and after flight. In other studies, greater frequencies of positive samples and greater numbers of copies of viral DNA have been found. No increases in titer of antibodies to these viruses were found, suggesting that an immune response may not be necessary for reactivation.

  17. Urinary indices in llamas fed different diets.

    PubMed

    Lackey, M N; Belknap, E B; Salman, M D; Tinguely, L; Johnson, L W

    1995-07-01

    Indices of renal function and damage were measured in 12 healthy male adult llamas fed a diet of mixed alfalfa/grass hay (mixed hay) and water ad libitum. Using a collection bag fitted over the preputial area, urine samples were collected at 6, 12, and 24 hours. Serum samples were obtained concurrently to determine endogenous creatinine clearance (CL), total (TE) and fractional excretion (FE) of electrolytes (Na, K, Cl, P), electrolyte CL, urine and serum osmolality, urine enzyme activities (gamma-glutamyltransferase and N-acetyl-beta-D-glucosaminidase), and urine protein concentration. Urine production was quantified. Three months later, 10 of the 12 llamas were fed a grass hay diet and water ad libitum. Similar samples were obtained, and similar measurements were made. Urine production was higher when the llamas were fed the mixed hay diet. Total urine volume for llamas fed mixed hay ranged from 628 to 1,760 ml/24 h, with a median of 1,307.5 ml/24h, compared with a range of 620 to 1,380 ml/24 h and a median of 927.50 ml/24h for llamas fed grass hay. Median urine osmolality was higher in llamas fed mixed hay (1,906 mOsm/kg of body weight, with a range of 1,237 to 2,529 mOsm/kg), compared with llamas fed grass hay (1,666 mOsm/kg with a range of 1,163 to 2,044 mOsm/kg). Creatinine CL did not vary significantly over time for either diet.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review.

    PubMed

    Emwas, Abdul-Hamid; Luchinat, Claudio; Turano, Paola; Tenori, Leonardo; Roy, Raja; Salek, Reza M; Ryan, Danielle; Merzaban, Jasmeen S; Kaddurah-Daouk, Rima; Zeri, Ana Carolina; Nagana Gowda, G A; Raftery, Daniel; Wang, Yulan; Brennan, Lorraine; Wishart, David S

    The metabolic composition of human biofluids can provide important diagnostic and prognostic information. Among the biofluids most commonly analyzed in metabolomic studies, urine appears to be particularly useful. It is abundant, readily available, easily stored and can be collected by simple, noninvasive techniques. Moreover, given its chemical complexity, urine is particularly rich in potential disease biomarkers. This makes it an ideal biofluid for detecting or monitoring disease processes. Among the metabolomic tools available for urine analysis, NMR spectroscopy has proven to be particularly well-suited, because the technique is highly reproducible and requires minimal sample handling. As it permits the identification and quantification of a wide range of compounds, independent of their chemical properties, NMR spectroscopy has been frequently used to detect or discover disease fingerprints and biomarkers in urine. Although protocols for NMR data acquisition and processing have been standardized, no consensus on protocols for urine sample selection, collection, storage and preparation in NMR-based metabolomic studies have been developed. This lack of consensus may be leading to spurious biomarkers being reported and may account for a general lack of reproducibility between laboratories. Here, we review a large number of published studies on NMR-based urine metabolic profiling with the aim of identifying key variables that may affect the results of metabolomics studies. From this survey, we identify a number of issues that require either standardization or careful accounting in experimental design and provide some recommendations for urine collection, sample preparation and data acquisition.

  19. Profiling a multiplex short tandem repeat loci from human urine with use of low cost on-site technology for verification of sample authenticity.

    PubMed

    Pires, Nuno M M; Tao Dong; Berntzen, Lasse; Lonningdal, Torill

    2017-07-01

    This work focuses on the development of a sophisticated technique via STR typing to unequivocally verify the authenticity of urine samples before sent to laboratories. STR profiling was conducted with the CSF1PO, TPOX, TH01 Multiplex System coupled with a smartphone-based detection method. The promising capability of the method to identify distinct STR profiles from urine of different persons opens the possibility to conduct sample authenticity tests. On-site STR profiling could be realized with a self-contained autonomous device with an integrated PCR microchip shown hereby.

  20. Significant increase in cultivation of Gardnerella vaginalis, Alloscardovia omnicolens, Actinotignum schaalii, and Actinomyces spp. in urine samples with total laboratory automation.

    PubMed

    Klein, Sabrina; Nurjadi, Dennis; Horner, Susanne; Heeg, Klaus; Zimmermann, Stefan; Burckhardt, Irene

    2018-04-13

    While total laboratory automation (TLA) is well established in laboratory medicine, only a few microbiological laboratories are using TLA systems. Especially in terms of speed and accuracy, working with TLA is expected to be superior to conventional microbiology. We compared in total 35,564 microbiological urine cultures with and without incubation and processing with BD Kiestra TLA for a 6-month period each retrospectively. Sixteen thousand three hundred thirty-eight urine samples were analyzed in the pre-TLA period and 19,226 with TLA. Sixty-two percent (n = 10,101/16338) of the cultures processed without TLA and 68% (n = 13,102/19226) of the cultures processed with TLA showed growth. There were significantly more samples with two or more species per sample and with low numbers of colony forming units (CFU) after incubation with TLA. Regarding the type of bacteria, there were comparable amounts of Enterobacteriaceae in the samples, slightly less non-fermenting Gram-negative bacteria, but significantly more Gram-positive cocci, and Gram-positive rods. Especially Alloscardivia omnicolens, Gardnerella vaginalis, Actinomyces spp., and Actinotignum schaalii were significantly more abundant in the samples incubated and processed with TLA. The time to report was significantly lower in the TLA processed samples by 1.5 h. We provide the first report in Europe of a large number of urine samples processed with TLA. TLA showed enhanced growth of non-classical and rarely cultured bacteria from urine samples. Our findings suggest that previously underestimated bacteria may be relevant pathogens for urinary tract infections. Further studies are needed to confirm our findings.

Top